Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Size: px
Start display at page:

Download "Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)"

Transcription

1 Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts, two normally open and two normally closed, can be added in the field. Description Cat. No. Auxiliary Contact ( V) C-N Auxiliary Contact ( V DC) C-N Lug Kit ( per kit) Continuous Current Rating [A] Wire Size Cat. No. / MCM C-LK () # MCM C-LK () # MCM C-LK Control Module Side-mounted module for DC input voltage Continuous Current Rating [A] Input Voltage Cat. No. // V DC C-N V DC C-N Control Pak Side-mounted module for DC coil power Continuous Current Rating [A] Input Voltage Cat. No. /V AC C-CPD /V AC C-CPA /V AC C-CPN /V AC C-CPB / /V AC C-CPD /V AC C-CPA /V AC C-CPN /V AC C-CPB Coil Kit Contains DC coil mounted in the sheet metal frame assembly that attaches to the contactor mounting plate Continuous Current Rating [A] Input Voltage Control Pak Voltage Cat. No. /V AC C-PKD /V AC C-PKA V DC /V AC C-PKN /V AC C-PKB V DC C-PKG V DC C-PKH /V AC C-PKD /V AC C-PKA V DC /V AC C-PKN /V AC C-PKB V DC C-PKG V DC C-PKH /V AC C-PKD /V AC C-PKA V DC /V AC C-PKN /V AC C-PKB V DC C-PKG V DC C-PKH Vacuum Interrupter Phase Assembly Kit Replacement for one vacuum interrupter phase Current Rating of Interrupter [A] Cat. No. A Vacuum Interrupter Phase Assembly C-VB A Vacuum Interrupter Phase Assembly C-VB A Vacuum Interrupter Phase Assembly C-VB Publication A-CAA-EN-P -

2 Bulletin C Non-Reversing Product Overview/Catalog Number Explanation/Product Selection Bulletin C Voltage: V AC maximum Current ratings:,, and A Space-saving design Line and load terminals up front for ease of wiring Visual ON/OFF indicator Snap-on side mount auxiliary contacts Typical industry applications include: Mining Foundries-metal processing Chemical Petroleum Cement Cranes & Hoists Pumps Other harsh environments where voltages above V are used The Bulletin C open type contactor is designed for use up to V. Vacuum contactors are particularly well-suited for mining, pumping, and other applications where voltages above V are used. The Bulletin C line uses vacuum bottles to enclose the power-switching contacts within the contactor. The use of vacuum technology results in particularly effective arc extinguishing above V and results in a very compact, long-lasting contactor. Table of Contents Product Selection... this page Accessories... - Specifications... - Approximate Dimensions... - Standards Compliance UL CSA. No. EN- (V) Certifications culus Listed (File No. E; Guide No. NLDX, NLDX) Configuration of a Basic Vacuum Contactor The information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection. C B O D Continuous Current Rating [A] Description B C D O a b NEMA Enclosure Type Type Open type no enclosure Product Selection -Phase, V Maximum, Hz a b c d c Control Voltage Voltage Frequency A V AC Hz B V AC Hz D V AC Hz N V AC Hz G V DC H V DC d Options Description -pole contactor Capacitor Switching [kvar] Transformer Primary Switching [kva] Continuous Current V V V V V V V V V V Rating [A] Cat. No. C-BO C-CO C-DO Motor Switching Ratings V / V V / V V / V V / V V / V V V [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] Cat. No. C-BO C-CO C-DO Control Voltage The cat. no. is incomplete. To complete the cat. no., select a control voltage code from the table below and insert into the cat. no. Example: Cat. No. C-BO becomes Cat. No. C-BOD. [V] AC / Hz D A N B DC G H Inrush current should be less than % of IEC AC operational current. For use on transformers having an inrush not more than times the rated full load current irrespective of secondary load. Ratings do not apply to transformers used in resistive welder service. Terminal lugs not included see Accessories on page -. - Publication A-CAA-EN-P

3 Bulletin NEMA Non-Reversing Product Overview/Catalog Number Explanation/Product Selection Configuration of a Basic Vacuum Starter Bulletin Voltage: V AC maximum Current ratings:,, and A Overload protection Time-proven eutectic or solid-state overload protection with current transformers Solid-state E Plus with wide : adjustment range Line and load terminals up front for ease of wiring Visual ON/OFF indicator Snap-on side-mount auxiliary contacts Mining Foundries-metal processing Chemical Petroleum Cement Cranes & Hoists Pumps Other harsh environments where voltages above V are used The Bulletin open-type starter is designed for use up to V. Vacuum starters are particularly well-suited in mining, pumping, and other harsh environments where voltages above V are used. The Bulletin line uses vacuum bottles to enclose the power-switching contacts within the starter. The use of vacuum technology results in particularly effective arc extinguishing above V and results in a very compact, long-lasting starter. Table of Contents Product Selection... this page Accessories... - Specifications... - Approximate Dimensions... - Standards Compliance UL CSA. No. EN- (V) Certifications culus Listed (File No. E; Guide No. NLDX, NLDX) The information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection. B O D EEJ a b c d Continuous Current Rating [A] Description B C D O a b NEMA Enclosure Type Type Open type no enclosure Product Selection -Phase, V, Hz Control Voltage Voltage Frequency A V AC Hz B V AC Hz D V AC Hz G V DC H V DC N V AC Hz c Blank d Overload Relay Current Description Starter Size Range [A] Eutectic alloy Heater elements,, EEJ EEW E Plus solid-state EEM Motor Switching Ratings V V V V V V Continuous [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] Current Rating [A] Cat. No. -BO - -CO - -DO - The cat. no. is incomplete. To complete the cat. no., select a control voltage code from the table below and insert into the cat. no. Example: Cat. No. -BO becomes Cat. No. -BOD. [V] AC / Hz D A N B Overload Relay Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from below to complete the cat. no. Example: Cat. No. -BOD- becomes Cat. No. -BOD-EEJ. Solid-State Overload Relay for -Phase Applications: Automatic/Manual Reset, Class,,, or Size Full Load Current Adjustment Range [A] Automatic/Manual Reset Overload Relay EEJ EEW EEM Publication A-CAA-EN-P -

4 Bulletin C Reversing Product Overview/Catalog Number Explanation/Product Selection Bulletin C [V] AC / Hz D A DC G Terminal lugs not included see Accessories on page -. Voltage: V AC maximum Current ratings:,, and A Visual ON/OFF indicator Line and load terminals up front for ease of wiring Mechanical and electrical interlock Horizontal construction for easy panel mounting Snap-on side mount auxiliary contacts Typical industry applications include: Mining Foundries-metal processing Chemical Petroleum Cement Cranes & Hoists Pumps Other harsh environments where voltages above V are used The Bulletin C reversing contactor consists of two Bulletin C vacuum contactors mounted horizontally on a common base. Contactors are mechanically and electrically interlocked to avoid both contactors being closed simultaneously. Vacuum contactors are particularly well-suited for mining, pumping, and other applications where voltages above V are used. Table of Contents Product Selection... this page Accessories... - Specifications... - Approximate Dimensions... - Standards Compliance UL CSA C., No. Certifications culus Listed (File No. E; Guide No. NLDX, NLDX) Configuration of a Basic Vacuum Contactor The information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection. Continuous Current Rating [A] Description B C D a C B O D a b c O b NEMA Enclosure Type Type Open type No enclosure Control Voltage Voltage Frequency A V AC Hz D V AC Hz G V DC Product Selection -Phase, V Maximum, Hz Motor Switching Ratings Cont. V V V V V V V Current Rating [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [Hp] [kw] [A] Cat. No. C-BO C-CO C-DO Control Voltage The cat. no. is incomplete. To complete the cat. no., select a control voltage code from the table below and insert into the cat. no. Example: Cat. No. C-BO becomes Cat. No. C-BOD. c - Publication A-CAA-EN-P

5 Bulletin C,, C Specifications/ Specifications Standards A A A EN - V UL CSA. V Power Ratings EN - V UL CSA. V EN - V UL CSA. V Insul. & Operating Voltage V V V Rated Fequency Hz Hz Hz Making Current Capacity A A A Breaking Current Capacity A A A Dielectric Strength Kv - Min. Interrupter GAP Kv - Min. Interrupter GAP Kv - Min. Interrupter GAP Interrupting Current (Max.). ka. ka ka Short Circuit Withstand (Max.) ka symmetrical V AC ka symmetrical V AC ka symmetrical V AC Mechanical Life Elect. Life AC Duty Switching Frequency (Mechanical) C, C /hr (max.)./s (full cycle) /hr (max.)./s (full cycle) /hr (max.)./s (full cycle) Withstand current for sec [ka]... Chop Current Max.. A. A. A Control Ratings Coil Voltage Operation -% +% -% +% -% +% Inrush Power VA VA VA VA Sealed Power VA VA VA VA Opening Time [ms] Closing Time [ms] Pick-Up Voltage % Cold % Hot % Cold % Hot % Cold % Hot Drop-Out Voltage % or less % or less % or less Application Ratings Mounting Installation All planes All planes All planes Altitude ft ( m) ft ( m) ft ( m) Ambient Storage - + F (- C) - + F (- C) - + F (- C) Operating Temperature - + F (- C) - + F (- C) - + F (- C) Vibration/Shock Hz: G/ G Hz: G/ G Hz: G/ G Bulletin C ( A). (.). (.). (.). (.). () () Mounting for / Screws.. (.) (.). (.) Optional Aux. Contact Kit. (.). (.). (.). (.). (.) - Publication A-CAA-EN-P

6 Bulletin C,, C Bulletin C ( A and A). (.). (.).. (.) R. (.) (.) () Mtg. Holes. (.). (.). (.). (.). (.). (.). (.) Ø. (.). (.). (.). (.). (.) A. (.). (.). (.). (.) R. (.) () Mtg. Holes. (.). (.). (.). (.). (.). (.). (.) Ø. (.). (.). (.). (.). (.) A Preferred availability cat. nos. are bold. Publication A-CAA-EN-P -

7 Bulletin C,, C Bulletin ( A) With E Plus Overload. (.). (.) RESET CL. (.) places. (.). (.). (). (.). (.) RESET CL. (.). (.). (.). (.). (.). (.). (.) - Publication A-CAA-EN-P

8 Bulletin C,, C Bulletin ( A) With Eutectic Overload. (.). (.) places. (.) RESET CL. (.). (.). (). (.). (.). (.) RESET CL CL. (.). (.). (.). (.). (.). (.) Publication A-CAA-EN-P -

9 Bulletin C,, C Bulletin ( A) With E Plus Overload - Publication A-CAA-EN-P

10 Bulletin C,, C Bulletin ( A) With Eutectic Overload Publication A-CAA-EN-P -

11 Bulletin C,, C Bulletin ( A) With E Plus Overload - Publication A-CAA-EN-P

12 Bulletin C,, C Bulletin ( A) With Eutectic Overload Publication A-CAA-EN-P -

13 Bulletin C,, C Bulletin C (,, A) B E C A D Contactor Size [A] A Height. (). () () B Width () () () C Depth. (). (). () D Mounting Height (). (). () E Mounting Width (). (). () - Preferred availability cat. nos. are bold. Publication A-CAA-EN-P

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max. Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max. Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......

More information

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg. Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

NEMA Contactor and Starter Specifications

NEMA Contactor and Starter Specifications Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Ratings for Switching AC Motors AC-2, AC-3, AC / / Bulletin -C/-C Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Ie [A] Bulletin -C/-C Compact sizes from kw/ Hp ( A) AC and DC coil control Common accessories for all contactor

More information

Single, dual, and multi-tap primary voltages Single phase EN finger-safe protection RoHS compliant 1497 A M1 3 N

Single, dual, and multi-tap primary voltages Single phase EN finger-safe protection RoHS compliant 1497 A M1 3 N Bulletin Product Overview/Catalog Number Explanation Cat. No. -B-HXJX--N Control Circuit Transformer, - pole with Optional Cat. No. -R Fuse Cover Cat. No. -C-BASX--N Control Circuit Transformer, Non-Fused

More information

CI-tronic Soft start motor controller

CI-tronic Soft start motor controller Data sheet CI-tronic Soft start motor controller MCI 3, MCI 15, MCI, MCI 30 I-O, MCI 40-3D I-O and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus

More information

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Ratings for Switching AC Motors AC-2, AC-3, AC / / Bulletin S-C/S-C IEC Safety Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin S-C/S-C IEC Safety Contactors Mechanically linked N.C. auxiliary contacts

More information

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6 Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition

More information

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2

More information

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type: DILEM 10(220V50HZ,240V60HZ) Article No.: Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230

More information

Supplemental Motor Protection Devices Table of Contents

Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Bulletin 0S/S//... Page - Bulletin 0 Arcing Ground Fault Detection System: Adjustable Trip from A... Page -

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

DISCONNECT SWITCHES. UL Listed CSA Certified

DISCONNECT SWITCHES. UL Listed CSA Certified POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole

More information

Bulletin 700-RTC Solid-State Timing Relay

Bulletin 700-RTC Solid-State Timing Relay Bulletin 700-RTC Solid-State Timing Relay Bulletin 700 RTC Solid State Timing Relay Timing functions 8 ON-delay 8 OFF-delay Timing ranges Seconds: 0.05 2, 0.2 8, 0.4 30, 2 120 Minutes: 0.015 1, 0.06 4,

More information

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0

More information

NEMA Size 1 Cat. No. CN55DN3AB

NEMA Size 1 Cat. No. CN55DN3AB -80 Contactors and Contents Description Product Family Overview Page Product Description....... -78 Features................ -78 Standards and Certifications........... -78 Selection.............. -79

More information

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current

More information

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance

More information

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil Product data sheet Characteristics LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Type: DILEM 10 G(24VDC) Article No.:

Type: DILEM 10 G(24VDC) Article No.: Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220

More information

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil Product data sheet Characteristics LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 -

More information

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) 4 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact Footprint Superior

More information

Characteristics 5 TeSys k contactors and reversing contactors

Characteristics 5 TeSys k contactors and reversing contactors 90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

Connection Diagrams. Auxiliary 40 C 60 C 24/48V 120V 240V 400V 500V 600V 690V Contacts Contacts N.O. N.C. Contacts 43 K

Connection Diagrams. Auxiliary 40 C 60 C 24/48V 120V 240V 400V 500V 600V 690V Contacts Contacts N.O. N.C. Contacts 43 K Bulletin Overview/Product Selection Προδυχτ Σελεχτιον Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUA Red Cover and

More information

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4 /0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors

More information

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87 Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................

More information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00

More information

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty. Page -2 Page - DIRECT-ON-LINE STARTERS Motor ratings up to 9A 0V in IEC AC duty General use up to 6A / motor rating up to 2A 600V per UL/CSA Versions with Start-Stop/Reset buttons or Reset button Versions

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

PKZ 2 Manual Motor Protectors Technical Data

PKZ 2 Manual Motor Protectors Technical Data 08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3

More information

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Bulletin 700-R -RM Sealed Switch Relays

Bulletin 700-R -RM Sealed Switch Relays Bulletin 700-R -RM Sealed Switch Relays Bulletin 700 R, RM Sealed Switch Relays Sealed contacts Extremely long mechanical and electrical life Hazardous locations Class 1, Div Groups A, B, C, D Harsh environments

More information

General 2 Approvals 3 Technical Information 5 Mounting Information 6

General 2 Approvals 3 Technical Information 5 Mounting Information 6 Index Page General 2 Approvals 3 Technical Information 5 Mounting Information 6 Mini Contactors 7 Mini Contactors 8 Interface Contactors 8 Mini Reversing Contactors 4 Technical Information 5 Dimensions

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3. 6-4 Freedom Pump Panels Circuit reaker R Enclosure / -Phase Magnetic / Interchangeable eater OLR These ECN Irrigation Pump Controllers feature the Cutler-ammer Freedom Series starters. They have a AND/OFF/AUTO

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M Characteristics Pendant control stations, for control circuits Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 XAC-B : standard version : NEMKO, CSA 300 V type 4 Approvals XAC-M : standard

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU /0 Mini contactors B and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU Contents Mini Contactors B, BC, B 7, BC 7 Ordering Details... /2 Compact Reversing

More information

Motor starters. TeSys E. Designed for the essential

Motor starters. TeSys E. Designed for the essential Motor starters TeSys E Designed for the essential Designed for the essential Contents TeSys E contactors, 6 A to 300 A TeSys E thermal overload relays 0.1 A to 333 A TeSys E control relays 4 NO/NC contacts

More information

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC

More information

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start Bulletin -HR Plug-in iming Relays Product election/catalog Number Explanation Bulletin ON-Delay iming Relays ocket or Panel Mounted iming Range From. s h -pin base for socket cat. nos. -HN, -HN, -HN rigger:

More information

Deploying Current Transformers in Applications Greater Than 200 A

Deploying Current Transformers in Applications Greater Than 200 A Deploying Current Transformers in Applications Greater Than 200 A Andrew Schaeffler Step-down Current Transformers (CTs) are common, and useful, in large motor applications. They provide isolation between

More information

XT IEC Power Control Miniature Controls

XT IEC Power Control Miniature Controls Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)

More information

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay A Power Relay with Various Models High-sensitivity ( mw) and High-capacity ( A) Models available. Low profile:.7 mm max. in height Conforms to VDE (EN0-), UL and CSA.. Meets EN0- requirements

More information

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays Miniature & Starters Series family of, Starters, and Overload & Industrial Relays Miniature, Starters, Overload Relays & Industrial Controls List Prices shown in this selection guide are for use in the

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

Low Pass Harmonic Filters

Low Pass Harmonic Filters Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >

More information

Crane Control Class 7001

Crane Control Class 7001 Catalog 17 CONTENTS Description.....................................................Page.................................................. 0 ST DC Static Timer............................................

More information

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series ABB Contactors Fits 35mm DIN rail Touch Safe Design Compact Design Captive Terminal Screws Built in surge protection (AF series only) Magnetic coil (AE series only) Electronically controlled coil (AE series

More information

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b Low profile safety relay with forcibly guided double contacts SFN4D RELAY 3.3 33.0 FEATURES Relay complies with EN 020, Type B. Polarized magnet system with snap action function Tolerance ±0.3 mm Weight

More information

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc Product Facts Designed to be the smallest, lightest weight, lowest cost sealed contactor in the industry with its current rating (500+A carry, 2000A interrupt at 320VDC) Built-in coil economizer only 1.7W

More information

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en Contactors Series C7, C6, C6, C65 Single pole contactors for battery voltages Catalogue B.en Contactors for battery voltages C7, C6, C6, C65 Series With its proven line of C7 through C65 Series contactors

More information

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays Series - Modular Solid State Relay 5 A 77 Features 77.01.x.xxx.8050 77.01.x.xxx.8051 5 A modular SSR, 1 NO output 17.5 mm housing 60 to 240 V AC output (with back to back SCR) 5 kv (1.2/50 μs) insulation

More information

Supplemental Motor Protection Devices Specifications

Supplemental Motor Protection Devices Specifications Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Page 809S/813S/814S/817 Dedicated Function Motor Protection Relays 2 Product

More information

DPC F - P3-24. Part Number Scheme. Dimensions

DPC F - P3-24. Part Number Scheme. Dimensions Description Definite Purpose Contactor Definite Purpose contactors are electrically operated switching devices specifically designed for the heating, ventilation, air conditioning, heat pump and refrigeration

More information

Single Phase Soft Starters

Single Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (877) 304-0724

More information

Bulletin 1497 Global Control Transformers

Bulletin 1497 Global Control Transformers Bulletin 1497 Global Control Transformers Bulletin 1497 Global Control Circuit Transformers Bulletin 1497 Global Control Circuit Transformers are designed to reduce supply voltages to control circuits.

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Compact Combination Starters Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for

More information

Switches Unlimited Contact: Phone: Fax:

Switches Unlimited Contact: Phone: Fax: Phone: 8--87 Fax: 78-67-67 - C Coil Three Pole - Series C7 C7 Non-Reversing, Three Pole With C Coil, Series C7 (Open type only) [] Ratings for Switching C Motors (C / C / C) kw (5 Hz) UL/CS HP (6 Hz) uxiliary

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

For Immediate Delivery call KMParts.com at (866)

For Immediate Delivery call KMParts.com at (866) Return To MAIN INDEX Magnetic Contactors, Overview / Contactors DIL...M Contactors AC Operated AC Operated, Reversing DC Operated AC/DC Operated, DC Hp ratings / /6 /8 / Starters DIL Universal Contactors

More information

Supplemental Motor Protection Devices Specifications

Supplemental Motor Protection Devices Specifications Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Bulletin 809S/813S/814S/817S 2 Page Product Line Overview 2 Cat. No. Explanation

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.

More information

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples. Miniature High Capacity Relays with SPST-NO 0A and SPST-NO + SPST-NC A SPST-NO 0A and SPST-NO + SPST-NC A for power switching and output that satisfy the needs for space-saving. Small High-capacity Relays

More information

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend PC Power Relay A Miniature Relay with -pole A/5A Switching Capability and 0 kv Impulse Withstand Voltage Highly efficient magnetic circuit for high sensitivity (200 mw). Small, yet provides 0-kV impulse

More information

Standard voltages. Alternating current (V). Direct current (V) D F H J N Y Voltage For contactors type CL...

Standard voltages. Alternating current (V). Direct current (V) D F H J N Y Voltage For contactors type CL... Series CL Three and four pole contactors 9 to 05 (C3) 25 to 40 (C) Contactors lternating current up to 690V Direct current up to 440V Terminal numbering in accordance with EN 50005 and EN 5002 Fixing by

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

507-1A H - - C. Features. Type List. Ordering Information

507-1A H - - C. Features. Type List. Ordering Information Type List Standard type Teral style Contact form High rating iature PCB Relay. AC & DC coil are both available. UL/CUL and VDE approved. 7A 77VAC SPDT. Low profile mm and high insulation system class.

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A Load break switches standards UL and CSA The solution for Load break switches sircm_1_a_1_cat > Power distribution Strong points Function Rotary switch SRCO M 3 x 1 A SRCO M load break switches are compact

More information

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947 Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit

More information

Bulletin 700-HX Multifunction Digital Timing Relay

Bulletin 700-HX Multifunction Digital Timing Relay Bulletin 700-HX Multifunction Digital Timing Relay Model Operating Mode Timing Range Socket Type Contact Output No. of Pins Input Voltage Cat. No. Cat. No. 700 HX A mode: Signal ON-Delay 1 A-1 mode: Signal

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

Distribution/Substation Transformer

Distribution/Substation Transformer Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation

More information

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Dry Type Transformers Full Line Catalog. jeffersonelectric.com Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production

More information

General Purpose Drives

General Purpose Drives AC Variable Speed Drive General Purpose Drives Dedicated to Low Power Applications 0.37kW 11kW / 0.5HP 15HP 200 480V 3 Phase Input AC Variable Speed Drive 0.37kW 11kW / 0.5HP 15HP 110 480V Single & 3 Phase

More information