IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

Size: px
Start display at page:

Download "IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection"

Transcription

1 IPS INTELLIGENT PUMP STARTER With TM Smartstart Ø & Ø, 0/60 Hz, 20~600 VAC, /~00HP Integrated electronic pump protection overload Power metering and data logging options Motor Protection Key dealer yr. warranty on your panel and motor! NEMA Tru-Power TM Sensing Tru-power sensing protects pumps from dry-run, dead head, runout, and jammed impeller conditions - keeping you online and preventing costly premature pump failure. Along with superior protection, measuring underload using power allows for a more flexible trip range, as opposed to measuring by current, which requires a more precise set point. The end result is the elimination of nuisance trips. Power No Load Full Load Current No Load Power is linear for superior load monitoring Full Load Optional Ethernet card provides time-stamped data logging, ending utility power disputes Download and display up to 00 faults and alarms, including operational mode and values of operation at the time of fault All power condition values are stored by phase for voltage, current, and power factor per fault Data is easily displayed and saved on any web browser using an Ethernet connection. The IPS incorporates internal web-server. No additional software required Time and date stamped for utility documentation Integrated Tru-power electronic motor and pump protection Eliminates need for costly pump protection relays Dry pump detection using power (nuisance trip-free); time-based automatic restart and well recovery mode Features a wide-range, adjustable, class -0 electrionic overload Provides superior motor protection from the following conditions: Over/under power (dry-run) Over/under voltage protection Voltage phase loss Voltage and Current phase unbalance Stalled/locked rotor Cycle fault Ground fault (UL0 certified) Voltage phase reversal Built-in power monitoring and fault logging for easy troubleshooting View voltage, current, power factor, and more through an intuitive display Quickly identify common power problems such as phase imbalance, voltage drop, and over/undercurrent conditions to ensure proper pump operation Built-in fault log, counter and parameter change log: records last fault types with power condition values, stores how many times each fault type has occurred (up to 2 count), and logs changes to paramter settings (e.g. FLA, OV/UV, under power) franklin-controls.com

2 The internal keypad and LCD make the IPS-RV intuitive and versatile. Parameters are easily changed and faults are clearly displayed. > Standard control features include a 2-20V auto run input (irrigation control system, etc.), shutdown terminal for applications such as a low level float switch, and more. > Our multi-tap power transformer accepts inputs of: 200V 20V 60V > Easy to setup and use Inside, the display shows an easy to use menu for setting a wealth of parameters. Adjust any protective or control setting in seconds. For example, choose how long to allow for dry well recovery, set run time periods, and On/Off delays. All this with just a few intuitive keystrokes. The IPS ships with factory default settings pre-programmed for optimal submersible pump protection. Industrial grade construction Door mounted heavy-duty HOA switch Housed in an outdoor rated, gasketed, NEMA R enclosure Multi-tap control power transformer with integrated secondary protection accomodates common motor voltages. No fuses required! Includes 20 VAC control power for field devices NEMA/IEC rated magnetic contactors feature 2. million electrical cycles at full rated current. Advanced programmable pump control matic fault reset Backspin delay - Prevents start-ups into draining systems On and Off delay settings Well recovery mode (up to 8 hours) Minumim run time based on last input 2-20 V input for remote start/stop Dry contact input for remote start/stop Standard circuit breaker disconnect (Service Entrance rated) UL 89 circuit breaker provides branch and short circuit protection No fuses required saves time and money Lockable handle for safety franklin-controls.com

3 Ordering and Sizing Information (20~60 VAC) *DPV = Differs per voltage **Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range. Intelligent Pump Starter - & -Phase, 0/60 Hz, 20~60 VAC NEMA Type R Enclosed - Combination Starter 20 V - 20 V -Phase SFA 200 V - 60 V -Phase SFA -PHASE HP (UL) / Max. FLA** -PHASE HP (UL) / Max. SFA** 20 V 20 V 200 V 20 V 60 V 600 V IPSR-S/J-G 6~8 6~8 / IPSR-S/J-G20 8~ 8~ / IPSR-S/J-G0 ~7 ~ IPSR-S/J-G0 6~22 6~ IPSR-SP/J-G0 20~28 20~ IPSR-SP/J-G60 2~ 2~ IPSR-S2/J-G80 2~ 2~ IPSR-S/J-G00 0~7 0~ IPSR-S/J-G2 0~7 0~ IPSR-SP/J-G0 60~8 60~ IPSR-S/J-G200 80~DPV* 80~ IPSR-S/J-G20 00~DPV* 00~DPV* IPSR-S/J-G00 N/A 20~ IPSR-S/J-G00 N/A 60~ IPSR-S/J-G00 N/A 20~ IPSR-SP/J-G600 N/A 20~ IPSR-SP/J-G800 N/A 20~DPV* Intelligent Pump Starter with Ethernet Fault Logging - & -Phase, 0/60 Hz, 20~60 VAC NEMA Type R Enclosed - Combination Starter 20 V - 20 V -Phase SFA 200 V - 60 V -Phase SFA -PHASE HP (UL) / Max. FLA** -PHASE HP (UL) / Max. SFA** 20 V 20 V 200 V 20 V 60 V 600 V IPSR-S/J-G-E 6~8 6~8 / IPSR-S/J-G20-E 8~ 8~ / IPSR-S/J-G0-E ~7 ~ IPSR-S/J-G0-E 6~22 6~ IPSR-SP/J-G0-E 20~28 20~ IPSR-SP/J-G60-E 2~ 2~ IPSR-S2/J-G80-E 2~ 2~ IPSR-S/J-G00-E 0~7 0~ IPSR-S/J-G2-E 0~7 0~ IPSR-SP/J-G0-E 60~8 60~ IPSR-S/J-G200-E 80~DPV* 80~ IPSR-S/J-G20-E 00~DPV* 00~DPV* IPSR-S/J-G00-E N/A 20~ IPSR-S/J-G00-E N/A 60~ IPSR-S/J-G00-E N/A 20~ IPSR-SP/J-G600-E N/A 20~ IPSR-SP/J-G800-E N/A 20~DPV*

4 Ordering and Sizing Information (600 VAC) **Use SFA Range or Max. SFA when sizing for submersible motor applications. If an amperage value for SFA is not published on the motor name plate, consider SFA range to be FLA range. Intelligent Pump Starter - -Phase, 0/60 Hz, 600 VAC NEMA Type R Enclosed - Combination Starter 600 V -Phase SFA -PHASE HP (UL) / Max. FLA** -PHASE HP (UL) / Max. SFA** 20 V 20 V 200 V 20 V 60 V 600 V IPSR-S/6J-G 6~ IPSR-S/6J-G20 8~ IPSR-S/6J-G0 ~ IPSR-S/6J-G0 6~ IPSR-S/6J-G0 20~ IPSR-S2/6J-G60 2~ IPSR-S2/6J-G80 2~ IPSR-S/6J-G00 0~ IPSR-S/6J-G2 0~ IPSR-S/6J-G0 60~ IPSR-S/6J-G200 80~ IPSR-S/6J-G20 00~ IPSR-S/6J-G00 20~ IPSR-S/6J-G00 60~ IPSR-SP/6J-G00 20~ IPSR-SP/6J-G600 20~ Intelligent Pump Starter with Ethernet Fault Logging - -Phase, 0/60 Hz, 600 VAC NEMA Type R Enclosed - Combination Starter 600 V -Phase SFA -PHASE HP (UL) / Max. FLA** -PHASE HP (UL) / Max. SFA** 20 V 20 V 200 V 20 V 60 V 600 V IPSR-S/6J-G 6~ IPSR-S/6J-G20 8~ IPSR-S/6J-G0 ~ IPSR-S/6J-G0 6~ IPSR-S/6J-G0 20~ IPSR-S2/6J-G60 2~ IPSR-S2/6J-G80 2~ IPSR-S/6J-G00 0~ IPSR-S/6J-G2 0~ IPSR-S/6J-G0 60~ IPSR-S/6J-G200 80~ IPSR-S/6J-G20 00~ IPSR-S/6J-G00 20~ IPSR-S/6J-G00 60~ IPSR-SP/6J-G00 200~ IPSR-SP/6J-G600 20~ franklin-controls.com

5 IPS Options Factory Installable Options Description IPS-MODBUS* Modbus RTU Communications Card IPS-SRG20 Surge Suppressor, 200/20 V IPS-SRG80 Surge Suppressor, 60 V IPS-SRG600 Surge Suppressor, 600 V IPS-RPL Run Pilot Light, Green IPS-FPL Fault Pilot Light, Red IPS-SPB Start Push-Button Control IPS-STSP Start/Stop Push-Button Control (In Lieu of /Off/ Switch) IPS-2 2 VAC Control Circuit (In Lieu of 20 VAC Control Circuit) *Cannot be installed on IPS with Ethernet Fault Logging Dimensions *All measurements shown in inches Starter H W D IPSR-S/J-G IPSR-SP/J-G IPSR-S2/J-G IPSR-S/J-G 22 0 IPSR-SP/J-G IPSR-S/J-G IPSR-S/J-G IPSR-SP/J-G W H D

6 Wiring Diagram Standard wiring schematic shown, actual product wiring may vary depending on options selected IPS PCB Dry Inputs D D2 D See Table Relay Outputs Status O2 O Fault O CAT Input Voltage Inputs Run Shut Down V V V2 V 2-20VAC/DC Input A CON A2 COIL PWR Actuator Control Motor A2 Limit Switch A A 20VAC, 0.2A Output JDS N.O. Input DM CPT 20V To V/V Run N V V *See Notes & JAR 2-20VAC/DC Run Input Run 208V 20V 80V H2 TRANSFORMER PRIMARY CIRCUIT BREAKER SIZING H H VA V 208/ VA N/A N/A 00VA A A L L2 L GND TABLE MCCB STANDARD - HOA SWITCH OFF H A H H SURGE SUPPRESOR OL A B C CAT Output IPS-SPB OFF H A CON L T T L2 T2 T2 L T T 2 IPS-STSP STOP START M START PH NOTES:. DASHED LINES INDICATE FIELD WIRING 2. CHECKED BOES INDICATE FACTORY INSTALLED OPTIONS. REMOVE JUMPER JDS TO WIRE LIMIT SWITCH. WHEN JUMPER JAR IS PRESENT, TERMINALS V & H2 ACT AS CONNECTIONS FOR A NORMALLY OPEN, DRY CONTACT, AUTO RUN INPUT.. REMOVE JUMPER JAR TO USE V & V TERMINALS AS A VOLTAGE, AUTO RUN INPUT. APPLY 2~20VAC/DC TO ENERGIZE franklin-controls.com

7 Specification Starter Type IPS - Intelligent Pump Starter Combination - Service Rated, Suitable for use as a Service Disconnect NEMA Type R Enclosed User Interface Settings Adjustments -Off- Standard Control Operations Inputs Outputs Operational Environmental Voltage Internal Door mounted -position switch Accepts 2-0VAC/DC. Applying voltage will send a run command to the starter when in mode. Dry Contact Normally Open dry contact. When closed, the starter will be commanded to run when in mode. Shutdown Actuator Position Switch Status Relay Fault Relay Actuator Power Overload Type Power Fail Modes On/Off Time Delay Fault Reset Accepts 2-0VAC/DC. Applying voltage will open the contactor and the starter will not accept a run command /Off/ LEDs will flash. Normally Open dry contact. To be used in series with customer provided actuator contacts which disable the motor starter until the actuator is in position. (ie. The contactor will not close unless this contact is closed) Normally Open relay contact, 2VAC, 2VAC Normally Open relay contact, 2VAC, 2VAC 20VAC, 0.2A max. Electronic, I 2 t trip curve Restart in last mode (/Off/) with no delay (default) Restart in Off mode Restart in Off mode if power failure lasts longer than 2 seconds. Restart in last mode if powerfailure is less than 2 seconds. On/Off, Adjustable: seconds Adjustable: Manual or matic (default differs per motor protection feature) Ambient Operating Temp - to 0 F (-20 to 60 C) Ambient Storage Temp - to 8 F (-20 to 8 C) Relative Humidity % to 9% non-condensing Motor Protection Adjustment / Description Default Setting Overload Current Setting Range Differs per model Per SFA Overload Trip Class Adjustable: -0 0 Overload Service Factor Adjustable: Under Power On/Off, Adjustable: 0-99% of measured electrical input On / 60% Over Power On/Off, Adjustable: 0-200% of measured electrical input On / 20% Over / Under Voltage On/Off, Adjustable: +-2% over/under the nominal voltage setting On / 0% Voltage Phase Unbalance On/Off, Adjustable: -20% voltage phase deviation On / % Voltage Phase Loss Always On, Adjustable: -0% voltage phase deviation 0% Voltage Phase Sequence Reversal On/Off, Trips within 0. seconds upon voltage phase reversal detection On Ground Fault (UL 0 Certified) On/Off, Adjustable:.0-9.9A On / A Cycle Fault On/Off, Adjustable: Trip if cycle rate exceeds 20 starts/minute On Warm Start Provision On/Off, Delays motor restart based on calculated motor temperature On TM Smartstart Protection Adjustment / Description Default Setting Current Phase Unbalance On/Off, Adjustable: -0% current phase unbalance On / % Locked Rotor / Stall On/Off, Trips within 0. seconds On Out of Calibration Max Time to Start On/Off, Trips after 0 seconds if the FLA dial setting is incorrect (set above calculated FLA range), ie. Start current is outside of an acceptable range (fla setting * < inrush < fla setting * ). On/Off, Regardless of FLA or I 2 t curve, always trip at start if starting current is outside of an acceptable range (inrush / ) and still decreasing after 0 seconds. On On

SCM. STARTER CONTROL MODULE Installation & Operation Manual IMS-RV INTELLIGENT MOTOR SOFT STARTER

SCM. STARTER CONTROL MODULE Installation & Operation Manual IMS-RV INTELLIGENT MOTOR SOFT STARTER SCM STARTER CONTROL MODULE Installation & Operation Manual IMS-RV S.W. Version 7.006 SAFETY PRECAUTIONS To prevent injury and property damage, follow these instructions. Failure to adhere to installation/operation

More information

MODEL 421 Over/Under Motor Load Monitor

MODEL 421 Over/Under Motor Load Monitor MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart

More information

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION! INSTALLATION INSTRUCTIONS FOR SYMCOM S OVERLOAD RELAY MODEL 777-MV-FT BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS

More information

SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD

SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD Plug-In MILLIMETERS DIN Rail DESCRIPTION Phase Monitor Relays (3-Phase Monitors) provide cost-effective protection against premature

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777- MV ELECTRONIC OVERLOAD RELAY MEDIUM VOLTAGE

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777- MV ELECTRONIC OVERLOAD RELAY MEDIUM VOLTAGE INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777- MV ELECTRONIC OVERLOAD RELAY MEDIUM VOLTAGE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS

More information

S11 Adjustable Speed Drive Engineering Specification

S11 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National

More information

SECTION AUTOMATIC TRANSFER SWITCH

SECTION AUTOMATIC TRANSFER SWITCH SECTION 26 36 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, withstand and close-on ratings as shown on the plans.

More information

INSTALLATION INSTRUCTIONS FOR THE MODEL 777 ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR THE MODEL 777 ELECTRONIC OVERLOAD RELAY INSTALLATION INSTRUCTIONS FOR THE MODEL 777 ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE

More information

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1 INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 02/2010 MODELS 201A-AU 201-575-AU II_201A-AU_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605)

More information

CONNECTIONS. TABLE 1: Wiring Configuration Based on Motor Amps. FIGURE 1: Typical Wiring Diagram

CONNECTIONS. TABLE 1: Wiring Configuration Based on Motor Amps. FIGURE 1: Typical Wiring Diagram INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-LR-TS ELECTRONIC OVERLOAD RELAY, 2-10 AMPS BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS

More information

Supplemental Motor Protection Devices Specifications

Supplemental Motor Protection Devices Specifications Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Page 809S/813S/814S/817 Dedicated Function Motor Protection Relays 2 Product

More information

Supplemental Motor Protection Devices Specifications

Supplemental Motor Protection Devices Specifications Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Bulletin 809S/813S/814S/817S 2 Page Product Line Overview 2 Cat. No. Explanation

More information

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2

More information

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems Softstarters Type PST Low Voltage Products & Systems 2 Low Voltage Products & Systems 1SXU132171M0201 [AC 1006.8] - 5/03 ABB Inc. 888-385-1221 www.abb.com/lowvoltage Softstarters Type PST Specification

More information

Variable Frequency Drives

Variable Frequency Drives Table of Contents Variable Frequency Drives Product Product Code Resource Documents Page # Introduction F-3 SED2 154-042 F-5 with Conventional Bypass Option SED2 154-044 F-9 with Electronic (E) Bypass

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

OPERATING INSTRUCTIONS FOR SYMCOM S INFORMER DIAGNOSTIC TOOL

OPERATING INSTRUCTIONS FOR SYMCOM S INFORMER DIAGNOSTIC TOOL OPERATING INSTRUCTIONS FOR SYMCOM S INFORMER DIAGNOSTIC TOOL INFORMER OPERATION The Informer is a handheld diagnostic tool for use with single-phase PumpSaver and PumpSaver Plus models equipped with infrared

More information

KW/HP-P2 INSTALLATION INSTRUCTIONS POWER MONITOR. Revision A1 Rapid City, SD, USA, 01/2010 II_777-KW-HP-P2_A1

KW/HP-P2 INSTALLATION INSTRUCTIONS POWER MONITOR. Revision A1 Rapid City, SD, USA, 01/2010 II_777-KW-HP-P2_A1 INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 01/2010 MODEL POWER MONITOR 777-KW/HP-P2 777-575-KW/HP-P2 II_777-KW-HP-P2_A1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848

More information

Phoenix DX Clean Power (18 Pulse) AC Drive

Phoenix DX Clean Power (18 Pulse) AC Drive PHOENIX DX Phoenix DX Clean Power (18 Pulse) AC Drive Poor power quality can be costly. Nonlinear loads, including AC Drives, introduce undesirable harmonic currents into the power system that can damage

More information

BACnet- MS/TP COMMUNICATION V

BACnet- MS/TP COMMUNICATION V - MS/TP COMMUNICATION V1.00.08.17 11.1 Introduction The VFD can be controlled and monitored through the BACnet MS/TP protocol over an RS-485 connection. The VFD operates as an MS/TP master device, which

More information

VMX CONFIGURED SOFT STARTER SERIES... 8 VMX-S Configured Series... 9 VMX-H Configured Series... 10

VMX CONFIGURED SOFT STARTER SERIES... 8 VMX-S Configured Series... 9 VMX-H Configured Series... 10 TABLE OF CONTENTS INDEX Page VMX COMPACT SOFT STARTER SERIES... 3 VMX Series Module Only... 4 VMX Series Enclosed... 5 VMX Series Dimensions and Weights - Module... 6 VMX Series Dimensions and Weights

More information

AF91 Adjustable Frequency Drives Series B

AF91 Adjustable Frequency Drives Series B Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based

More information

Guidelines to Using a Three Phase Voltage Monitor

Guidelines to Using a Three Phase Voltage Monitor September 2000 Guidelines to Using a Three Phase Voltage Monitor Introduction A phase monitor can be used with any three phase motor. A monitor such as the Copeland 085-0160-00 is recommended for monitoring

More information

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice. Instruction Manual Bypass Panels FRENIC-EcoPAK Fuji Electric Corp. of America FECA-IN-105 / 122010 Information subject to change without notice. Safety Precautions Read this manual thoroughly before proceeding

More information

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION! INSTALLATION INSTRUCTIONS FOR SYMCOM S OVERLOAD RELAY MODEL 777-FT BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

More information

VF-nC1 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba VF-nC1 AC Variable Frequency Drives, 6 pulse for 100V single-phase 0.1 to 0.75kW, 200V single-phase 0.2 to 2.2kW and 200V threephase 0.1

More information

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters Section [26 35 26][16280] Active Harmonic Filters (Low Voltage) Part 1 General 1.1 Summary A. Scope: Provide design and engineering, labor,

More information

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED SECTION 16280 LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED PART 1 - GENERAL 1.1 SUMMARY This specification defines the requirements for active harmonic filter systems in order to meet IEEE-519-2014

More information

General Purpose Drives

General Purpose Drives AC Variable Speed Drive General Purpose Drives Dedicated to Low Power Applications 0.37kW 11kW / 0.5HP 15HP 200 480V 3 Phase Input AC Variable Speed Drive 0.37kW 11kW / 0.5HP 15HP 110 480V Single & 3 Phase

More information

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION GUIDE SPECIFICATIONS 256920-UGS-A-0506 Simplicity Intelli-Comfort Optional Control in 3-25 Ton Packaged Units GENERAL DESCRIPTION CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP Equipment with Simplicity

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

ADJUSTABLE SPEED DRIVES FS1

ADJUSTABLE SPEED DRIVES FS1 ADJUSTABLE SPEED DRIVES FS1 Now Available With LonWorks BACnet & MetasysN2 FS1 Model FLA & Dimensions (in.)/ Weight (lbs.) VOLTAGE HP MODEL NUMBER FLA FRAME Dimensions (in.) SHIPPING H W D WEIGHT (lbs.)

More information

Power Processor - Series 700F 10KVA to 150KVA

Power Processor - Series 700F 10KVA to 150KVA Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

PACSystems* RX3i IC695MDL765

PACSystems* RX3i IC695MDL765 March 2011 PACSystems* RX3i IC695MDL765 Digital Output Module with Diagnostics 16-Channel The 24/125 volt DC 2A Smart Digital Output module, IC695MDL765, provides 16 discrete outputs in two isolated groups

More information

ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP

ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP Product information presented here re fl ects con di tions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO:

More information

Variable Frequency Drives Basic Operating Principles and Core Maintenance Considerations

Variable Frequency Drives Basic Operating Principles and Core Maintenance Considerations Variable Frequency Drives Basic Operating Principles and Core Maintenance Considerations By: Tom Reilly Account Manager, W&WW Industry - NC / SC / VA Rockwell Automation / Allen-Bradley 704-287-1178 (mobile)

More information

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e FIGURE 12-1 Basic relay construction. FIGURE 12-2 Shading coil in AC relays. 1 FIGURE 12-3 Contactor coil and shaded pole stators. FIGURE 12-4 Magnetic motor starter. 2 FIGURE 12-5 Thermal overload devices.

More information

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK PART 1.0 GENERAL 1.1 SCOPE A. This specification contains the minimum requirements for the design, manufacture and testing of a UL listed,

More information

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse ADJUSTABLE SPEED DRIVES HX7 Series 18-Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion

More information

ES-777-MV-P2_A1 03/01/10

ES-777-MV-P2_A1 03/01/10 ENGINEERING SPECIFICATION SYMCOM MODEL 777-MV-P2 Electronic Overload Relay PART 1 GENERAL 1.1 REFERENCES A. UL 508 Industrial Control Equipment Underwriters Laboratories B. IEC 60947 Low Voltage Switchgear

More information

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features SECTION 5 INDEX DESCRIPTION Cover Page - Electric Actuators & Accessories Standard & Optional Features OM Actuator Standard Features OM Actuator Optional Features V / Actuator Selection Chart OM1 Actuator

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps. VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload

More information

ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP

ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649

More information

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

AV-300i Specifications. Saftronics Inc.  PC10 Product Specifications PC10. Mini Vector AC Drive Saftronics Inc. www.saftronics.com TM AV-300i Specifications PC10 Product Specifications PC10 Mini Vector AC Drive 1 (1) T hree-phas e 230V input Drive Hp 1/8 1/4 1/2 1 2 3 5 7.5 10 Nominal applicable

More information

FDM Medium Voltage Controller

FDM Medium Voltage Controller 1-1 LMR PLUS Product Description For over 50 years, EATON Corporation has been the industry leader in Medium Voltage Motor Control. The FDM Medium Voltage Fire Pump Controller is based on the AMPGARD controller

More information

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control. Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)

More information

Design Specifications Operator Keypad Environmental and Operating Conditions

Design Specifications Operator Keypad Environmental and Operating Conditions Series 15J Mini Inverters Big inverter features do come in small packages! Take a look at Baldor s Series 15J Inverter control. Designed to save cabinet space without giving up the features available on

More information

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT RK-23/048RD100-7200 SPECIFICATION SCOPE This functional specification defines the performance characteristics of the switching mode regulated power supply, and also defines world wide safety requirements

More information

Installation, Programming Operation, & Maintenance Manual V

Installation, Programming Operation, & Maintenance Manual V Base Drive, Bypass Drive, Drive with Disconnect 200~480V (3~28A) Q-Link Manual Fan & Pump Optimized Variable Frequency Drive Installation, Programming Operation, & Maintenance Manual V2.00.09.17 CAUTION,

More information

P Series. Installation, Programming Operation, & Maintenance Manual. Fan & Pump Optimized Variable Frequency Drive.

P Series. Installation, Programming Operation, & Maintenance Manual. Fan & Pump Optimized Variable Frequency Drive. I n t e l l i g e n t M o t o r C o n t r o l s P Series Fan & Pump Optimized Variable Frequency Drive P Series Manual 0.5 40HP (200~230VAC), 3Ø 0.5 700HP (380~480VAC), 3Ø 0.5-150HP (525~600VAC), 3Ø Dual

More information

BC145 SIGNAL ISOLATOR BOARD

BC145 SIGNAL ISOLATOR BOARD BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download

More information

E3 Adjustable Speed Drive Engineering Specification

E3 Adjustable Speed Drive Engineering Specification E3 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba E3 AC Variable Frequency Drives, 6 pulse for 230V and 460V. 1.1 References A. National

More information

NEW DIGITAL PUMP LOAD CONTROL

NEW DIGITAL PUMP LOAD CONTROL NEW DIGITAL PUMP LOAD CONTROL Power sensor monitors true motor power Waterproof & rugged, large red LED display Compact enclosure with flexible fittings Easy front panel keypad set up Low and high setpoint

More information

RSi SG Series Sensorless Vector Variable Frequency Drive

RSi SG Series Sensorless Vector Variable Frequency Drive RSi SG Series Sensorless Vector Variable Frequency Drive 7.5 to 40HP - 230V 7.5 to 700HP - 460V 7.5 to 150HP - 600V Instruction Manual 890046-00-01 2012 Benshaw Inc. Benshaw retains the right to change

More information

VARIABLE FREQUENCY DRIVE SPECIFICATION

VARIABLE FREQUENCY DRIVE SPECIFICATION VARIABLE FREQUENCY DRIVE SPECIFICATION 1.0. SUMMARY The use of variable frequency drives (VFDs) in conjunction with wastewater lift stations has been identified as a means improve efficiency and to moderate

More information

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse ADJUSTABLE SPEED DRIVES W7 Series 18 Pulse Meets or Exceeds Your Specifications Standard Specifications Item Voltage Class 460V Maximum HP 60 75 100 125 150 200 250 300 400 500 600 700 800 Drive Rating

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified 8/23/17 Updated sections on System Design and Performance Requirements; Submittals; Equipment; Accessories or Special Features; Quality

More information

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES KBDA SERIES ADJUSTABLE FREQUENCY DRIVES FOR 3-PHASE AC MOTORS NEMA-4X / IP-65 Washdown and Watertight for Indoor and Outdoor use MULTI-FUNCTION KEYPAD WITH 4-DIGIT LED DISPLAY Simplified Group Programming

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only. This document is a short guide to how to connect, do the configuration and start the unit in the easiest way. Refer to the Instruction Manual IMAE-01, appropriate revision of Axpert-Eazy Series AC Drive

More information

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual INDEX A AC Drive Cover: 1 6 Dimensions: 2 4 External Parts and Labels: 1 6 Heat Sink Fins: 1 6 Input Mode Switch (Sink/Source): 1 6 Introduction to DuraPulse GS3 AC drive: 1 3 Keypad: 1 6 Model Number

More information

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE 1 2 SERIES 1 2 pag. 4 pag. 5 Applications Model identification 3 pag. 5 4 pag. 6 Capacity

More information

Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS

Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS To prevent injury and property damage, follow these instructions during the installation and operation of VFD.

More information

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web:  - ADJUSTABLE SPEED DRIVES HX7 Series 18 Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion

More information

Gutor PxW AC UPS Designed for North American Market

Gutor PxW AC UPS Designed for North American Market Gutor PxW AC UPS Designed for North American Market PEW 5 200 kva single phase PDW 10 220 kva three phase Higher ratings upon request schneider-electric.com 2 schneider-electric.com schneider-electric.com

More information

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General Section 16621A - AUTOMATIC TRANSFER SWITCH Part 1 General 1.01 One 600 Amp, 3 Phase, 480 Volt Automatic Transfer Switch (ATS) shall be provided with gasketed enclosure. The ATS shall consist of an inherently

More information

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards The Solo, Select and Sync PWM boards provide a pulse-width modulated (PWM) signal to the EC motor to control fan speed.

More information

Single Phase Soft Starters

Single Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (877) 304-0724

More information

AC Magnetic Starters (GE)

AC Magnetic Starters (GE) AC Magnetic Starters (GE) Description of Operation With Local or Remote Start-Stop Selector Switch (LVR) Control Starting Stopping Restarting Turning the selector switch to START energizes M and starts

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

Product Catalog PRODUCT CATALOG. Power supply system & test equipment Product Catalog PRODUCT CATALOG 2018 2018 Power supply system & test equipment. 138/79, Moo 2 Tambon Ban Klang, Amphoe Mueang Pathumthani, Pathumthani Province 12000, Thailand. Tel: +66 21475048-9 Fax:

More information

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design

More information

CONTROL MANUAL. Dry-Pic 09PE - 09VE

CONTROL MANUAL. Dry-Pic 09PE - 09VE CONTROL MANUAL Dry-Pic 09PE - 09VE Translation of the original document 003, 04.01 EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth

More information

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual Hitachi P1 Closed Loop Hoist Basic Instruc on Manual DH Firmware V.18 DETROIT HOIST AND CRANE LLC, CO. 6650 STERLING DRIVE NORTH STERLING HEIGHTS MICHIGAN 48312 Introduction This manual only applies to

More information

MOTOR MANAGER RELAY INSTRUCTION MANUAL. Copyright 1993 Multilin All Rights Reserved. The 301 is CSA approved. 215 Anderson Avenue 9746 Whithorn Dr.

MOTOR MANAGER RELAY INSTRUCTION MANUAL. Copyright 1993 Multilin All Rights Reserved. The 301 is CSA approved. 215 Anderson Avenue 9746 Whithorn Dr. 301 MOTOR MANAGER RELAY INSTRUCTION MANUAL Software Rev: 301.D1.20 Manual P/N: 1601-0014-D4 Copyright 1993 Multilin All Rights Reserved The 301 is CSA approved. CANADA USA Multilin Multilin Division of

More information

Fan and Pump AC Inverter

Fan and Pump AC Inverter Fan and Pump AC Inverter Key Features for Fan and Pump Applications PID and Auto Energy Saving Functions. Input Phase Loss and Output Phase Loss Protection. LCD Keypad can be used to copy parameter settings

More information

StatiVolt. Inverter UPS Systems. Features. Contents

StatiVolt. Inverter UPS Systems. Features. Contents Redundant, clean, sine-wave AC power ensures a high availability of mission-critical safety devices, instrumentation, alarms, controls and computers. Robust, StatiVolt UPS Systems are designed and built

More information

Installation & Operation Manual RSDA SERIES. ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65

Installation & Operation Manual RSDA SERIES. ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65 Installation & Operation Manual RSDA SERIES ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65 Washdown and Watertight for Indoor and Outdoor Use MULTI-FUNCTION KEYPAD WITH 4-DIGIT LED DISPLAY

More information

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12 INSTRUCTION MANUAL Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS Power Factor Controller A12 1. CONTENTS 1. CONTENTS 1 2. FEATURES 2 3. INSTALLATION, CONNECTION AND APPLYING POWER 2 4.

More information

AEROCONNECT 1B NA C Control manual

AEROCONNECT 1B NA C Control manual AEROCONNECT 1B NA 11.3 C 03-01 Control manual EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth 1. Sensor connections 1.6 Communication

More information

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Variable Frequency Drive / Inverter (0.4 ~ 280kW) Variable Frequency Drive / Inverter (0.4 ~ 280kW) & Standard Features Configuration Comparison Comparison Table Enclosure IP00 IP20 NEMA 1 Rating Single phase 0.4 2.2kW 0.4 1.5kW Three phase 0.4 4kW Constant

More information

TC 204 Heating Controller

TC 204 Heating Controller TC 204 Heating Controller ver. 1.32-01 The TC204 is a multi-purpose heating controller with built-in programs for different types of heating systems. General Data Power requirement 24 volts ac, 2 va Inputs

More information

ASTAT-XT RVSS PANEL. Table of Contents. Installation and Start-up Instructions for ASTAT-XT RVSS Bypass & Non Bypass Panels DEH40620

ASTAT-XT RVSS PANEL. Table of Contents. Installation and Start-up Instructions for ASTAT-XT RVSS Bypass & Non Bypass Panels DEH40620 DEH 40621 Instruction Table of Contents Section Topic Thanks information DEH40627 Installation and Start-up Instructions for ASTAT-XT RVSS Bypass & Non Bypass Panels DEH40620 Operating and Troubleshooting

More information

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay Technical Datasheet RELAY-1 RELAY-2 k V Hz RESET ABH TEST True RMS Measurement True RMS Digital Protection V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics Power IT LV Active Filters PQFI PQFM PQFK The ABB comprehensive solution for active filtering of harmonics Harmonics and Power Quality Power Quality relates to the amplitude, frequency and distortion of

More information

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter.

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter. Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS To prevent injury and property damage, follow these instructions during the installation and operation of the inverter. Incorrect

More information

Microprocessor Control Board Set Up Procedures (OR PLC)

Microprocessor Control Board Set Up Procedures (OR PLC) Microprocessor Control Board Set Up Procedures (OR-00 PLC) SWITCHES/PUSHBUTTONS Push Buttons at display SW Enter button SW Back button SW Down SW UP Back light on/off switch Rotary switches on main board

More information

User's Guide. AC Circuit Load Tester. Model CT70

User's Guide. AC Circuit Load Tester. Model CT70 User's Guide AC Circuit Load Tester Model CT70 Introduction Congratulations on your purchase of the CT70 AC Circuit Load Tester. This device can detect circuit and wiring problems such as: Poor ground

More information

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual vacon 100 flow ac drives application manual vacon 1 TABLE OF CONTENTS Document: DPD01083A Version release date: 16.11.12 Corresponds to software package FW0159V121106.vcx 1. Vacon 100 FLOW - Quick Startup

More information

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control NEW FIRMWARE MAKES SETUP A SNAP Application based commissioning allows parameters

More information

SECTIONS , (15040, 15767, 15950, 16269) Guide Specification for VARIABLE SPEED DRIVES with Optional Bypass

SECTIONS , (15040, 15767, 15950, 16269) Guide Specification for VARIABLE SPEED DRIVES with Optional Bypass PART 1: GENERAL 1.01 SCOPE A. This specification describes the electrical, mechanical, environmental, agency and reliability requirements for three phase, variable speed drives as specified herein and

More information

SECTION VARIABLE FREQUENCY DRIVES MEDIUM VOLTAGE

SECTION VARIABLE FREQUENCY DRIVES MEDIUM VOLTAGE SECTION 16349 VARIABLE FREQUENCY DRIVES MEDIUM VOLTAGE PART 1 GENERAL 1.1 SCOPE A. This Specification defines the requirements for Medium Voltage Variable Frequency Drive Systems (VFD s) for the operation

More information

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL 1.01 SUMMARY: The following technical specification describes the requirements of the high accuracy standalone 3 phase Power

More information

Metering Devices, Protective Relays, Software and Connectivity

Metering Devices, Protective Relays, Software and Connectivity , Protective Relays, Software and Connectivity.3 IQ Analyzer 6400/6600 Series IQ Analyzer Comprehensive Electrical Distribution Monitoring IQ Analyzer 6400/6600 Series Product Description Eaton s IQ Analyzer

More information

BLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany

BLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany 2354235 11/2008 Soft start - soft stop unit SH31 User manual 09/2010 BLEMO Frequenzumrichter Siemensstraße 4 D-63110 Rodgau Dudenhofen Germany Tel.: ++49 / 6106 / 82 95-0 Fax: ++49 / 6106 / 82 95-20 Internet:

More information