SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD

Size: px
Start display at page:

Download "SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD"

Transcription

1 SLU SERIES Universal Phase Monitor/Relay SLU-100-ASA and SLU-100-ASD Plug-In MILLIMETERS DIN Rail DESCRIPTION Phase Monitor Relays (3-Phase Monitors) provide cost-effective protection against premature equipment failure caused by voltage faults on 3-Phase systems (Wye or Delta). Until recently, different phase monitors were required to address voltage range and protection requirements for each individual power and motor circuit. The SLU Series multimode phase monitoring relay, was designed for the convenience of electricians, maintenance managers and engineers. A single SLU Phase Monitoring Relay can be easily adjusted for the voltage, imbalance percentage and time delay requirements to protect against unbalanced voltages or single phasing regardless of any regenerative voltages. Both Delta and Wye systems may be monitored. In Wye systems, connections to neutral are not required. NOTE: Not recommended for generator or variable frequency drive applications. Call technical support for application assistance. AUTO RANGING SCALES: See SLU Auto Ranging Scales Table VOLTAGE BAND Drop-out: ±10% of Range Setting (Under/Over) Pick-up: ±7% of Range Setting (Under/Over) MAIMUM VOLTAGE: 550 VAC (Line-to-Line) PHASE SEQUENCE: ABC (Will Not Operate On CBA Sequence) POWER REQUIRED: 90VA Maximum PHASE UNBALANCE 2% to 10%, Adjustable Drop-out HYSTERESIS: 10% of Setting PHASE SHIFT: 13 Drop-out, 12 Pick-up (Ø-Loss) FREQUENCY SHIFT 50/60 Hz Drop-out: ± 4% Pick up: ± 3% or Manual Mode RELAY OUTPUT: SPDT, 240VAC Resistive, 1/2 INDICATORS Flashing Continuous Normal (Green LED): Fault Delay Active Relay Energized Fault (Red LED): Restart Delay Active Relay De-energized TOP LABELS 277 Plug-In SLU AUTO RANGING SCALES DIN Rail Model Frequency Nominal Line-to-Line Adjustable Series Voltages Range SLU Hz 208, 220, SLU Hz 380, 415, 440, 460, SLU Hz 208, 220, SLU Hz 346, 380, SLU Hz 575, Power Up: 2.5 S Minimum Fault Delay: 0.1 to 25 S, Adjustable Severe Fault: 100mS (Phase-Loss, Unbalance or Phase Reversal) Restart: 0.5 to 300 S, Adjustable (Auto Reset) 32 F to 131 F (0 C to +55 C) -49 F to 185 F (-45 C to +85 C) REPEAT ACCURACY: Fixed Condition TERMINALS (DIN): Slotted Screw Terminal Clamps, 12AWG Max. ENCLOSURE: Style "A" LEAN Dust Cover DIN 35mm DIN Rail, 14 Term Polycarbonate Housing SOCKET RB-08

2 SLU SERIES Universal Phase Monitor/Relay SLU-600-ASTDS TOP LABEL MILLIMETERS FEATURES: ALL SLU'S DIN Rail Mount & Surface Mount Adjustable Restart Delay Adjustable Fault Delay Manual or Reset Adjustable Operating Range SLU-600: VAC 3-Phase Nominal PROTECTS AGAINST Rapid Cycling Phase Loss Phase Reversal Over/Under Voltage Phase Unbalance Phase Shift Over/Under Frequency AUTO RANGING SCALES: See Table Previous Page 3 Ø VOLTAGE BAND Drop-out: ±10% of Range Setting (Under/Over) Pick-up: ±7% of Range Setting (Under/Over) CONTROL VOLTAGE: 120 VAC ±10%, 50/60Hz MAIMUM VOLTAGE: 700 VAC (Line-to-Line) PHASE SEQUENCE: ABC (Will Not Operate On CBA Sequence) POWER REQUIRED: 90 VA Maximum PHASE UNBALANCE 2% to 10%, Adjustable Drop-out Hysteresis: 10% of Setting PHASE SHIFT: 13 Drop-out, 12 Pick-up (Ø-Loss) FREQUENCY SHIFT 50/60 Hz Drop-out: ± 4% Pick up: ± 3% or Manual Mode Clears Rapid Cycle Count RAPID CYCLING: 5 Cycle Lockout, 30-Min. Cycle Count Reset LED STATUS CHART Status Normal Under Over Unbal & Green Red Red Ø Loss Red LED LED LED LED Powering Up/First 3 Sec Powered Up/Normal Voltages Relay ON/Under Voltage Detected/FAULT DELAY active Relay ON/Over Voltage Detected/ FAULT DELAY active Relay ON/Unbal or Ø Loss Detected/FAULT DELAY active Relay OFF/Under Voltage Failure Relay OFF/Over Voltage Failure Relay OFF/Unbal or Ø Loss Failure Relay OFF/Under Voltage Corrected/ RESTART DELAY active Relay OFF/Over Voltage Corrected/ RESTART DELAY active Relay OFF/Unbal or Ø Loss Corrected/RESTART DELAY active 278 = OFF = ON = FLASHING RELAY OUTPUT: DPDT, 240 VAC Resistive INDICATORS Flashing Continuous Normal (Green LED): Fault Delay Active Relay Energized Under (Red LED): Restart Delay Active Relay De-energized Over (Red LED) Restart Delay Active Relay De-energized Unbal / Ø Loss (Red LED) : Restart Delay Active Relay De-energized Power Up: 2.5 S Minimum Fault Delay: 0.1 to 25 S, Adjustable Severe Fault: 100mS (Ø-Loss, Unbalance or Ø Reversal) Restart: 0.5 to 300 S, Adjustable (Auto Reset) 32 F to +131 F (0 C to +55 C) -49 F to +185 F (-45 C to +85 C) REPEAT ACCURACY: Fixed Condition TERMINALS: Plug and Socket Term Block with Spring Pressure Wire Retention, 12 AWG Max. ENCLOSURE: 35mm DIN Rail or Surface Mount, Polycarbonate Housing

3 SLU SERIES Multi-Mode Phase Loss Monitor SLU-OEM1 TOP LABEL DESCRIPTION The OEM1 single-adjust setup provides full multi-fault protection. Phase Monitor Relays (3-Phase Monitors) provide cost-effective protection against premature equipment failure caused by voltage faults on 3-Phase systems (Wye or Delta). Until recently, different phase monitors were required to address voltage range and protection requirements for each individual power and motor circuit. The SLU-OEM1 is ideally suited for original equipment manufacturers since the unit provides a scalable voltage adjustment from VAC (3Ø). The SLU-OEM1 has built in power up and fault delays. To minimize incidences of nuisance tripping while protecting against most power quality conditions associated with premature motor failure. Variations of the SLU-OEM1 are available upon request. Modifications can be made on % Phase Loss/Imbalance, Fault/Restart Delay, Frequency Shift and proprietary part numbers for low minimum quantities. Both Delta and Wye systems may be monitored. In Wye systems, connections to neutral are not required. NOTE: Not recommended for generator or variable frequency drive applications. Call technical support for application assistance. AUTO RANGING SCALES: VAC VOLTAGE BAND Drop-out: ±10% of Range Setting (Under/Over) Pick-up: ±7% of Range Setting (Under/Over) MAIMUM VOLTAGE: 550VAC (Line-to-Line) PHASE SEQUENCE: ABC (Will Not Operate On CBA Sequence) POWER REQUIRED: 90VA Maximum PHASE UNBALANCE: 5% Fixed, (Others available upon request) Hysteresis: 1% of Setting PHASE SHIFT: 13 Drop-out, 12 Pick-up (Ø-Loss) FREQUENCY SHIFT 50/60 Hz Drop-out: ± 5 Hz Pick-up: ± 4 Hz Mode 279 WIRING DIAGRAM PROTECTS AGAINST Phase Loss Phase Reversal Over/Under Voltage Phase Unbalance Frequency Shift Phase Shift RELAY OUTPUT: SPDT, 240VAC Resistive, 1/2 240VAC INDICATORS Flashing Continuous Normal (Green LED): Fault Delay Active Relay Energized Fault (Red LED): Restart Delay Active Relay De-energized Power Up: 2.5 S Minimum Fault Delay: 5 S Fixed Severe Fault:.5 S (Phase-Loss, Unbalance or Frequency) Restart: 2 S, Fixed ( Reset) 32 F to 131 F (0 C to +55 C) -49 F to 185 F (-45 C to +85 C) REPEAT ACCURACY: Fixed Condition ENCLOSURE: Style A LEAN Dust Cover 8-Pin Plug-In SOCKET RB-08

4 SLU SERIES 3-Phase Auto Ranging Rapid Cycling SLU-100-ASDS MILLIMETERS OPERATION The Line-to-Line voltage adjustment is set to the appropriate nominal voltage and frequency scale. There is infinite set point resolution between minimum and maximum on each scale. With normal operating voltage present on all three phases in the proper sequence, the internal relay will energize (pick-up). When an incorrect phase sequence, phase loss, under voltage, over voltage, frequency shift, or unbalance condition occurs greater than the settings, the internal relay will de-energize (drop-out). When all conditions return to normal and the adjustable Restart Delay expires, the relay will energize (pick-up). The Rapid Cycle lockout count must be less than 5. Both Delta and Wye systems may be monitored. In Wye systems, connections to neutral are not required. TOP LABEL AUTO RANGING SCALES: See Auto Ranging Table for SLU-100 s for the SLU-100-ASA VOLTAGE BAND Drop-out: ±10% of Range Setting (Under/Over) Pick-up: ±7% of Range Setting (Under/Over) MAIMUM VOLTAGE: 550 VAC (Line-to-Line) PHASE SEQUENCE: ABC (Will Not Operate On CBA Sequence) POWER REQUIRED: 90 VA Maximum PHASE UNBALANCE 2% to 10%, Adjustable Drop-out Hysteresis: 10% of Setting PHASE SHIFT: 13 Drop-out, 12 Pick-up (Ø-Loss) FREQUENCY SHIFT 50/60 Hz Drop-out: ± 4% Pick-up: ± 3% RAPID CYCLING: 5 Cycle Lockout, 30 Minute Cycle Count Reset Power Up: 2.5 S Minimum Fault Delay:.1 to 25 S, Adjustable Severe Fault: 100mS (Ø-Loss, Unbalance or Ø Reversal) Restart:.5 to 300 S, Adjustable (Auto Reset) RELAY OUTPUT: or Manual Mode SPDT, 240 VAC Resistive, 1/2 240 VAC INDICATORS Flashing Continuous Normal (Green LED): Fault Delay Active Relay Energized Under (Red LED): Restart Delay Active Relay De-energized Over (Red LED): Restart Delay Active Relay De-energized Unbal/Ø Loss (Red LED): Restart Delay Active Relay De-energized 32 F to +131 F (0 C to +55 C) -49 F to +185 F (-45 C to +85 C) REPEAT ACCURACY: Fixed Condition TERMINALS: ENCLOSURE: Slotted Screw Terminal Clamps, 12 AWG Max. 35MM DIN Rail, 16 Term Polycarbonate Housing 280

5 SLL SERIES 3-Phase Auto Ranging, Line and Load Side Monitor/Relay SLL-100-ASDS FEATURES Operating Ranges: VAC 3-Phase Rapid Cycle Lockout Phase Shift Detection DIN or Surface Mount Adjustable Restart Delay or Manual Reset OPERATION The Line-to-Line voltage adjustment is set to the appropriate nominal voltage and frequency scale. There is infinite set point resolution between minimum and maximum on each scale. With normal operating voltage present on all three phases in the proper sequence, the internal relay will energize (Pick-up). When an incorrect phase sequence, phase loss, under voltage, over voltage, frequency shift or unbalance condition occurs greater than the settings, the internal relay will de-energize (Drop-out). When all conditions return to normal, the relay will energize when the adjustable Restart Delay has expired. Both Delta and Wye systems may be monitored. In Wye systems, connections to neutral are not required. WIRING & TOP LABEL PROTECTS AGAINST Contactor Failure Overload Failure SEE SLU-100-ASDS AUTO RANGING SCALES: See Auto Ranging Table for SLU-100 s for the SLU-100-ASA VOLTAGE BAND Drop-out: ±10% of Range Setting (Under/Over) Pick-up: ±7% of Range Setting (Under/Over) MAIMUM VOLTAGE: 550 VAC (Line-to-Line) PHASE SEQUENCE: ABC (Will Not Operate On CBA Sequence) POWER REQUIRED: 90 VA Maximum PHASE UNBALANCE: 2% to 10%, Adj., Drop-out Hysteresis: 10% of Setting PHASE SHIFT: 13 Drop-out, 12 Pick-up (Ø-Loss) FREQUENCY SHIFT 50/60 Hz Drop-out: ± 4% Pick-up: ± 3% RAPID CYCLING: Cycle Lockout, 30 Min. Cycle Count Reset <5 Power Up: 2.5 S Minimum Fault Delay: 0.1 to 25 s, Adjustable Severe Fault: 100mS (Ø-Loss, Unbalance or Ø Reversal) Restart: 0.5 to 300 s, Adjustable (Auto Reset) or Manual Mode RELAY OUTPUT: SPDT, 240 VAC Resistive, 1/2 240 VAC INDICATORS Flashing Continuous Normal (Green LED): Fault Delay Active Relay Energized Fault (Red LED): Restart Delay Active Relay De-energized Over (Red LED): Restart Delay Active Relay De-energized Unbal/Ø Loss (Red LED): Restart Delay Active Relay De-energized 32 F to 131 F (0 C to +55 C) -49 F to 185 F (-45 C to +85 C) TERMINALS: ENCLOSURES: LED STATUS CHART Slotted Screw Terminal Clamps, 12 AWG Max. 35mm DIN Rail, 16 Term Polycarbonate Status Normal Under Over Unbal & Green Red Red Ø Loss Red LED LED LED LED Powering Up/First 3 Sec Powered Up/Normal Voltages Relay ON/Under Voltage Detected/ FAULT DELAY active Relay ON/Over Voltage Detected/ FAULT DELAY active Relay ON/Unbal or Ø Loss Detected/ FAULT DELAY active Relay OFF/Under Voltage Failure Relay OFF/Over Voltage Failure Relay OFF/Unbal or Ø Loss Failure Relay OFF/Over Voltage Corrected/ RESTART DELAY active Relay OFF/Over Voltage Corrected/ RESTART DELAY active Relay OFF/Unbal or Ø Loss Corrected/ RESTART DELAY active = OFF = ON = FLASHING

6 MPA SERIES SERIES DIN Rail Surface Mount Motor Performance Analyzer MILLIMETERS FEATURES Standard ( VAC) & Medium Voltage (VAC) Versions True RMS Monitoring Up to 1500 Amp Loads 3 External Clamp-On C.T.'s 9 Programmable Trip Points 9 Programmable Alarm Points 2 RTD Lead Compensated Temperature Inputs Time Tagged Fault History Power-up Auto Diagnostic DPDT Output; SPDT Alarm Output Bidirectional RS485 output Modbus RTU Protocol Built-in Real-Time Clock 2 x 16 Fluorescent Display No Control Voltage Required All English Programming (Scrolling Menu) Setpoint Change Lockout RELAY ACCURACY VOLTAGE: ±1% CURRENT: ±1% G.F. CURRENT: ±10% TIMING: 5% ±1 Second INPUT VOLTAGE MPA-1000: VAC 3-Phase (Nominal) MPA-1100: VAC 3-Phase ±20% (Nominal) FREQUENCY: 50/60 Hz PHASE SEQUENCE: ABC (will not operate CBA) OUTPUT CONTACT: DPDT; Form "C" 10A per pole max / 16 A 240 VAC ALARM OUTPUT: SPDT; Form "C" VAC COMMUNICATION OUTPUT: RS485 Modbus RTU BAUDRATE: PARITY: Even, None PROGRAMMABLE TRIP/ALARM POINT (Each setpoint can be disabled) LOW VOLTAGE: V RMS HIGH VOLTAGE: V RMS VOLTAGE UNBALANCE: 1-15% CURRENT UNBALANCE: 1-15% OVER CURRENT: Up to 100% of C.T. Range. Dependent on C.T. Range, FLA, and Trip Class. UNDER CURRENT: Up to 100% of C.T. Range GROUND FAULT: 2-13% of CT Range OVER TEMP. 1: C 3-wire 100Ω Platinum Input or 2-wire with jumper OVER TEMP. 2: C 3-wire 100Ω Platinum Input or 2-wire with jumper OVER CURRENT NEMA 5, 10, 15, 20, 30; TRIP CLASS: J jam protection can be enabled for all classes. DESCRIPTION The MotorGuardian TM is a microprocessor based overload relay, designed to provide protection for 3-Phase AC motors. It offers a broad range of features in one compact package providing a cost effective solution for monitoring and managing motor performance. A unique feature of the The MotorGuardian TM is its ease of installation. It is provided with Clamp- On C.T.'s that can accommodate up to 1500 ampere loads. Actual motor operating conditions are accessed by the scrolling menu and viewed by a two line highly visible vacuum fluorescent display. Fault conditions are also displayed indicating the specific cause of the occurring fault. There are two separate models that cover two input voltage ranges. The Model MPA-1000 has a direct input voltage range of VAC, 3-phase. The MPA-1100 has been designed to accept secondary volts from medium voltage transformers and has an input range of VAC, 3-phase. 282

7 MGR-1000 SERIES Remote Manager for MPA-1000 and MPA-1100 MILLIMETERS FEATURES MPA Remote Monitoring Total Control of MPA Functions Identical Keypad and Display as MPA-1000 and MPA-1100 NEMA 4 Protection 2 x 16 Vacuum Fluorescent Display Polycarbonate Enclosure with Captive Hardware Removable Input Terminal Block DESCRIPTION The MGR Remote Manager is part of the MotorGuardian family that is used in conjunction with the MPA Motor Performance Analyzer. It provides full control and monitoring of the MPA functions by mimicking the keypad and display. The front panel programming is identical to the MPA that simplifies the learning process. This external control provides an efficient and safe tool away from potentially dangerous voltages. The MGR is environmentally protected (NEMA 4) and is easily mounted using a cutout on the front of a control panel or MCC. A vacuum fluorescent display (VFD) was selected to provide high visibility in both high and low light situations. INPUT VOLTAGE: POWER CONSUMPTION: ENVIRONMENT: COMMUNICATION PORTS: 115/230 VAC ±15% Hz Model Selectable 3 Watts (Maximum) -10 C to +55 C NEMA 4 RS485 Modbus RTU Baudrate: 2400 to Parity: Even, None 284

8 PRA SERIES Phase Sequence Monitor Style A Style N Style A Style N 3.70" 3.225" DESCRIPTION The PRA-100 Series are designed to allow the output to energize only when the phase connections are in the proper sequence. For use in applications where motor direction is critical or the installation is required by code to have sequence detection. OPERATION When the phase sequence is correct and the operating voltage is present on all phases, the relay will energize and the green LED indicator will glow. If the phases are in reverse rotation, the relay will not energize and the red LED indicator will glow. The PRA-100 Series will not detect phase loss while the motor is turning..172" SLOT.205" Style E 2.18".185" 1.60" OPERATING VOLTAGE: VAC ±15%, phase-to-phase, 50/60 Hz PHASE SEQUENCE: ABC (Will Not Operate CBA) RESPONSE TIME: 200 msec. (approximately) OUTPUT RATING Style A & N: SPDT, VAC Resistive, 1/2 240 VAC Style E: DPDT, VAC Resistive, 1/2 240 VAC 32 F to +131 F (0 C to +55 C) -49 F to 185 F (-45 C to +85 C) TOTAL APPARENT POWER: VAC INDICATORS Green LED: Glows on correct sequence Red LED: Glows on incorrect sequence ENCLOSURES Style A : Model No. PRA-100-AFA, LEAN dust cover 8-Pin plug-in. RB-08 or OT-08 Socket WIRING DIAGRAM Style N : Model No. PRA-100-AFN, Glass filled VALO surface mounted 6-1/4" male quick connect Style E : LEAN Surface Mount Model No. PRA-100-AFE, #8-32 screws 285

9 SLA SERIES Phase Loss, Under Voltage and Phase Sequence Monitor/Relays Style A Diversified Phase Monitors operate independently of motor size or power requirements of the system. Some typical applications follow: Air Handlers Conveyor Drive Oil & Gas Pumps Elevator Drives Irrigation Pumps Power Substation Monitoring Lift Station Pumps Computer Power Protection Water Waste & Sewage Machinery Sawmill & Woodpump Machinery Transfer Switching for Emergency Power Supplies Commercial/Industrial Air Conditioning & Refrigeration Compressors Robotics Equipment OPERATION The SLA Series is designed to protect three-phase equipment against Phase Loss, Under Voltage, and Phase Reversal conditions. With normal operating voltages applied in the proper ABC sequence, the internal relay will energize (PICK-UP). When incorrect phase sequence or phase loss occurs or the three-phase voltages fall below the drop out voltages, the relay will de-energize (DROP-OUT). Both Delta and Wye systems may be monitored. In Wye systems, connections to neutral are not required. For UL Listed units, with field wiring terminals, copper wire with 60 / 75 C rating must be used for control circuitry connections. On models featuring indicators, the LED glows when all line conditions are normal. NOTE: When a phase is lost while the motor is running, a condition known as regeneration occurs where a voltage is induced into the open phase nearly equal in magnitude to the normal phase-to-phase voltage. However, with the exception of lightly loaded motors, enough change is detected by the SLA to provide the required protection when properly adjusted. DROP-OUT VOLTAGE 1 Ø Low: 83% of Nominal 3 Ø Low: 90% of Nominal Models Up to 300 VAC 250 Milliseconds 0.5 Seconds Models Over 300 VAC 1.0 Seconds 2.0 Seconds 32 to +131 F (0 to +55 C) -49 to +185 F (-45 to +85 C) PHASE SEQUENCE: ABC (Will Not Operate CBA) U.S. PATENT NUMBER: 3,611,050 GENERAL ORDER INFORMATION CODE SLA--A PHASE MONITOR OPERATING VOLTAGE Phase-to Phase TYPE OF OPERATION F Fixed L Lock Shaft Adj. S Screwdriver Adj. ENCLOSURE STYLE A Octal Plug-In, Dust Cover B Blade Plug-In, Dust Cover E Surface Mounted, #8 Screw Terminals N Surface Mounted, 1/4" Quick Disconnect Terminals OPTIONS R Add R Suffix when manual reset is required, (available only in style E enclosure) U Plug-In models are UL listed only when used with RB-08 relay socket. 287

10 SLA SERIES Phase Loss, Under Voltage and Phase Sequence Monitor/Relays Plug-In 2.375" 1.75" Style B Style A OPERATING VOLTAGE: See Table Below PHASE SEQUENCE: ABC (Will Not Operate CBA) POWER REQUIRED: 3 VA (Approximately) INDICATOR LED: Glows When All Conditions Are Normal (On Applicable Models) U.S. PATENT NUMBER: 3,611,050 Figure 1 Figure 2 Figure 3 RB-08 or OT-08 RB-11 QC-11 Models Up to 300 VAC 250 Milliseconds 0.5 Seconds Models Over 300 VAC 1 Second 2.0 Seconds MODEL NUMBER SLA-120-ALA SLA-120-ASA SLA-120-ASB SLA-230-ALA SLA-230-ASA SLA-230-ASB SLA-380-ASA SLA-440-ASA SUA-120-ALA SUA-120-ALAU* SUA-230-ALA SUA-230-ALAU* SUA-380-ASA SUA-440-ASA OPERATING VOLTAGE Adj Adj Adj Adj Adj Adj Adj Adj. TYPE OF ADJUSTMENT Lock Shaft Screwdriver Lock Shaft Screwdriver Lock Shaft Screwdriver DROP-OUT VOLTAGE 1 Ø LOW 3 Ø LOW AGENCY APPROVAL STOCK OUTPUT RATING --- DPDT, 345 VA Inductive; 10 Amps 240 VAC. Figure 2 SPDT, 345 VA Inductive; 10 Amps & CSA 240 VAC, Figure 1 SPDT, 345 VA Inductive; 10 Amps 240 VAC, Figure 3 DPDT, 345 VA Inductive; 10 Amps 240 VAC, Figure 2 SPDT, 345 VA Inductive; 10 Amps & CSA 240 VAC, Figure 1 SPDT, 345 VA Inductive; 10 Amps 240 VAC, Figure 3 & CSA & CSA & CSA & CSA & CSA *UL Listed only when used with RB-08 relay socket; 5 Amps 240 VAC. All voltages referenced on this page are phase-to-phase. Models also available with fixed operating voltages. Consult factory. SPDT, 360 VA Inductive; 10 Amps 240 VAC, Figure 1 SPDT, 345 VA Inductive; 10 Amps 240 VAC, Figure 1 SPDT, 360 VA Inductive; 10 Amps 240 VAC, Figure 1 UL Recognized UL Listed

11 SLA SERIES Phase Loss, Under Voltage and Phase Sequence Monitor Relays Surface Mounted Enclosure Style E OPERATING VOLTAGE: See Table Below PHASE SEQUENCE: ABC (Will Not Operate CBA) POWER REQUIRED Models Up to 300 VAC: 3 VA, Maximum Models Over 300 VAC: 7 VA, Maximum Models Over 500 VAC: 3 VA, Maximum INDICATOR LED: Glows When All Conditions Are Normal Models Up to 300 VAC 250 Milliseconds 0.5 Seconds Models Over 300 VAC 1.0 Second 2.0 Seconds U.S. PATENT NUMBER: 3,611,050 For UL Listed units, copper wire with 60 /75 C rating must be used for control circuitry connections. MODEL NUMBER SLA-120-ALE SLA-120-ALER SLA-230-ALE SLA-230-ALER SLA-380-ALE SLA-380-ALER SLA-440-ALE SLA-440-ALER SLA-575-ALE OPERATING VOLTAGE Adj Adj Adj Adj Adj. All models are UL Listed and CSA Certified. All voltage referenced on this page are phase-to-phase. DROP-OUT VOLTAGE 1 Ø LOW 3 Ø LOW RESET STOCK OUTPUT RATING DPDT, 211 VA Inductive; 10 Amps 120 VAC. Figure 1 Manual DPDT, 211 VA Inductive; 10 Amps 120 VAC. Figure DPDT, 345 VA Inductive; 5 Amps 240 VAC. Figure 1 DPDT, 360 VA Inductive; 3 Amps 600 VAC. Figure 1 DPDT, 360 VA Inductive; 3 Amps 600 VAC. Figure 1 Manual Manual Manual DPDT, 345 VA Inductive; 5 Amps 240 VAC. Figure 1 SPDT, 360 VA Inductive; 3 Amps 600 VAC. Figure 2 SPDT, 360 VA Inductive; 3 Amps 600 VAC. Figure DPDT, 360 VA Inductive; 3 Amps 600 VAC. Figure Models also available with fixed operating voltages. Consult factory.

12 SLA SERIES Phase Loss, Under Voltage and Phase Sequence Monitor/Relays Epoxy Encapsulated Style N OPERATING VOLTAGE: PHASE SEQUENCE: POWER REQUIRED: OUTPUT RATING: See Table Below ABC (Will Not Operate CBA) 3 VA, Maximum SPDT, 180 VA, Inductive; 10 Amps, 240 VAC 60 Milliseconds 0.5 Seconds U.S. PATENT NUMBER: 3,611,050 MODEL NUMBER SLA-120-AFN OPERATING VOLTAGE 120 TYPE OF OPERATION Fixed DROP OUT VOLTAGE 1 Ø LOW 3 Ø LOW SLA-208-AFN 208 Fixed SLA-220-AFN 220 Fixed SLA-240-AFN 240 Fixed All models are UL recognized. All voltages referenced on this page are phase-to-phase. 290

13 PBC SERIES 3-Phase Voltage Band Monitor Relay Style E OPERATION The PBC Series offers protection to three-phase equipment that is required to operate between two voltage limits. All three phases are monitored individually for a pre-selected under and over voltage limit. With normal operating voltages applied, the internal relay will energize (PICK-UP). When the voltages on any or all phases fall outside the preset Over/Under trip points for loner than the Release delay, the relay will de-energize (DROP-OUT). When line conditions return to normal, the PBC Series Monitor automatically resets and the internal relay energizes. The LED fault indicators aid in set up and system trouble-shooting. The respective LED glows on fault condition. The LED indicators have an immediate response to voltage conditions and operate independently of the relay. The HYSTERESIS in each unit provides a differential of 4% between the PICK-UP and DROP-OUT trip points. HYSTERESIS: 4% 100 Milliseconds OUTPUT RATING: INDICATORS LED: POWER REQUIRED Models Up to 300 VAC: Models Over 300 VAC: REPEAT ACCURACY: 0.5 Seconds DPDT, VAC, Resistive; VAC, Inductive; 1/2 hp Glows On Fault; (1) For Over, (1) For Under 32 to +104 F (0 to +40 C) -49 to +185 F (-45 to +85 C) 7 VA, Maximum 6 VA, Maximum Fixed Condition DELTA CONNECTED PBC-120-ALE PBC-230-ALE PBC-400-ALE PBC-440-ALE PBC-480-ALE PBC-575-ALE MAIMUM VOLTAGE 155 VAC 275 VAC 485 VAC 550 VAC 570 VAC 700 VAC ADJUSTABLE RANGES Under Over WYE CONNECTED PBC-120/208-ALE PBC-220/380-ALE PBC-277/480-ALE MAIMUM VOLTAGE 268 VAC 450 VAC 565 VAC ADJUSTABLE RANGES (phase-to-neutral) Under Over All voltages referenced on this page are phase-to-phase, unless otherwise indicated. 291

14 PBD SERIES 3-Phase Sequence and Voltage Band Monitor/Relays Style E OPERATION The PBD Series offers protection to three-phase sequence sensitive equipment that is required to operate between two voltage limits. All three phases are monitored individually for a pre-selected Under and Over voltage limit. With normal operating voltages applied in the proper ABC sequence, the internal relay will energize (PICK-UP). When the voltages on any or all phases fall outside the preset Over/Under trip points for longer than the Adjustable Release delay, the relay will de-energize (DROP-OUT). When line conditions return to normal, the PBD Series Monitor automatically resets and the internal relay energizes. Both Delta and Wye systems may be monitored. In Wye systems, connections to neutral are not required. The LED fault indicators aid in set up and system troubleshooting. The respective LED glows on fault condition. The LED indicators have an immediate response to voltage conditions and operate independently of the relay. In a phase reversal condition the LED indicators respond to voltage conditions but the relay will not energize. The Adjustable Release delay is provided to ignore momentary voltage fluctuations that cause nuisance tripping. The HYSTERESIS in each unit provides a differential of 4% between the PICK-UP and DROP-OUT trip points. PHASE SEQUENCE: ABC (Will Not Operate CBA) Hysteresis: 4% 100 Milliseconds 0.1 to 30 Seconds, Adjustable OUTPUT RATING: DPDT, VAC, Resistive; VAC, Inductive; 1/2 hp INDICATORS LED: Glows On Fault; (1) For Over, (1) For Under 32 to +104 F (0 to +40 C) -49 to 185 F (-45 to +85 C) POWER REQUIRED Models Up to 300 VAC: 7 VA, Maximum Models Over 300 VAC: 6 VA, Maximum REPEAT ACCURACY: Fixed Condition PBD-120-ALE PBD-230-ALE PBD-400-ALE PBD-440-ALE PBD-480-ALE PBD-575-ALE MAIMUM VOLTAGE 155 VAC 275 VAC 485 VAC 550 VAC 570 VAC 700 VAC ADJUSTABLE RANGES Under Over All voltages referenced on this page are phase-to-phase. 292

Voltage Monitors & Phase Monitors

Voltage Monitors & Phase Monitors Series Included 3-Phase Voltage Monitors WVM....110 DLMU...111 HLMU...112 PLMU...113 PLM...114 TVW....115 TVM....116 Low Volts, Phase Reversal PLR....117 Phase Reversal PLS....118 1-Phase Voltage Monitors

More information

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1 INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 02/2010 MODELS 201A-AU 201-575-AU II_201A-AU_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605)

More information

MODEL 421 Over/Under Motor Load Monitor

MODEL 421 Over/Under Motor Load Monitor MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart

More information

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION! INSTALLATION INSTRUCTIONS FOR SYMCOM S OVERLOAD RELAY MODEL 777-MV-FT BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE

More information

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection IPS INTELLIGENT PUMP STARTER With TM Smartstart Ø & Ø, 0/60 Hz, 20~600 VAC, /~00HP Integrated electronic pump protection overload Power metering and data logging options Motor Protection Key dealer yr.

More information

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2

More information

Monitors. voltage, phase, thermistor, current

Monitors. voltage, phase, thermistor, current CONNECTION AUTOMATION CONTROLS PROTECTION Monitors voltage, phase, thermistor, current NA8TOC2T 001222 Monitors 8 Table of contents VOLTAGE/PHASE MONITORS THREE-PHASE VOLTAGE MONITORS, MOTOR PROTECTORS

More information

Guidelines to Using a Three Phase Voltage Monitor

Guidelines to Using a Three Phase Voltage Monitor September 2000 Guidelines to Using a Three Phase Voltage Monitor Introduction A phase monitor can be used with any three phase motor. A monitor such as the Copeland 085-0160-00 is recommended for monitoring

More information

SHORT FORM. Product Catalog. (800) time-mark.com

SHORT FORM. Product Catalog. (800) time-mark.com SHORT FORM Product Catalog (800) 862-2875 time-mark.com 3-Phase Monitor Relays Time Mark has a variety of 3-phase relays that can offer protection against phase loss, phase reversal, phase unbalance and

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777- MV ELECTRONIC OVERLOAD RELAY MEDIUM VOLTAGE

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777- MV ELECTRONIC OVERLOAD RELAY MEDIUM VOLTAGE INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777- MV ELECTRONIC OVERLOAD RELAY MEDIUM VOLTAGE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS

More information

269 Troubleshooting Guide 11/4/98 1

269 Troubleshooting Guide 11/4/98 1 269 Troubleshooting Guide 11/4/98 1 Table of Contents Phase currents 3 Communications. 6 RTDs.. 9 Ground Fault Currents... 13 Output Relays. 15 Analog Output 17 Switch Inputs...18 11/4/98 2 Phase Currents

More information

INSTALLATION INSTRUCTIONS FOR THE MODEL 777 ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR THE MODEL 777 ELECTRONIC OVERLOAD RELAY INSTALLATION INSTRUCTIONS FOR THE MODEL 777 ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE

More information

KRPA, KRP, KA, KR series

KRPA, KRP, KA, KR series Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting

More information

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION! INSTALLATION INSTRUCTIONS FOR SYMCOM S OVERLOAD RELAY MODEL 777-FT BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

More information

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems Softstarters Type PST Low Voltage Products & Systems 2 Low Voltage Products & Systems 1SXU132171M0201 [AC 1006.8] - 5/03 ABB Inc. 888-385-1221 www.abb.com/lowvoltage Softstarters Type PST Specification

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17 Proximity Section 17 Table of Contents............ 21 2 Application Guide........................ 21 3 ACT Series Transducers......... 21 4 ACTR Series Transducers........ 21 6 ACS150 Series Switches..................

More information

KW/HP-P2 INSTALLATION INSTRUCTIONS POWER MONITOR. Revision A1 Rapid City, SD, USA, 01/2010 II_777-KW-HP-P2_A1

KW/HP-P2 INSTALLATION INSTRUCTIONS POWER MONITOR. Revision A1 Rapid City, SD, USA, 01/2010 II_777-KW-HP-P2_A1 INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 01/2010 MODEL POWER MONITOR 777-KW/HP-P2 777-575-KW/HP-P2 II_777-KW-HP-P2_A1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848

More information

MOTOR MANAGER RELAY INSTRUCTION MANUAL. Copyright 1993 Multilin All Rights Reserved. The 301 is CSA approved. 215 Anderson Avenue 9746 Whithorn Dr.

MOTOR MANAGER RELAY INSTRUCTION MANUAL. Copyright 1993 Multilin All Rights Reserved. The 301 is CSA approved. 215 Anderson Avenue 9746 Whithorn Dr. 301 MOTOR MANAGER RELAY INSTRUCTION MANUAL Software Rev: 301.D1.20 Manual P/N: 1601-0014-D4 Copyright 1993 Multilin All Rights Reserved The 301 is CSA approved. CANADA USA Multilin Multilin Division of

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

WD series DIN Rail or Screw Mounted Protective Relays

WD series DIN Rail or Screw Mounted Protective Relays WD series DIN Rail or Screw Mounted Protective Relays WD25 Paralleling (Synch Check) Relays WD2759 Over/undervoltage Relays WD32 Reverse Power Relays WD47 Phase Sequence Relays WD5051 Single- or Three-Phase

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

AF91 Adjustable Frequency Drives Series B

AF91 Adjustable Frequency Drives Series B Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based

More information

g GE POWER MANAGEMENT

g GE POWER MANAGEMENT 469 FREQUENTLY ASKED QUESTIONS 1 Can not communicate through the front port RS232 Check the following settings Communication port on your computer ( com1, com2 com3 etc ) Parity settings must match between

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 DPC01 PPC01 TRMS 3-phase over and under voltage, phase sequence, phase loss, asymmetry and tolerance monitoring relay Detect

More information

alternating relays catalog a of products com

alternating relays catalog a of products com alternating relays catalog a of products 800.238.7474 www.macromatic.com com sales@macromatic.com com ALTERNATING RELAYS Typical Installations Alternating Relays are used in special applications where

More information

NEW DIGITAL PUMP LOAD CONTROL

NEW DIGITAL PUMP LOAD CONTROL NEW DIGITAL PUMP LOAD CONTROL Power sensor monitors true motor power Waterproof & rugged, large red LED display Compact enclosure with flexible fittings Easy front panel keypad set up Low and high setpoint

More information

ES-777-MV-P2_A1 03/01/10

ES-777-MV-P2_A1 03/01/10 ENGINEERING SPECIFICATION SYMCOM MODEL 777-MV-P2 Electronic Overload Relay PART 1 GENERAL 1.1 REFERENCES A. UL 508 Industrial Control Equipment Underwriters Laboratories B. IEC 60947 Low Voltage Switchgear

More information

RCMS460 and RCMS490 Series

RCMS460 and RCMS490 Series 4 T M RCMS460 and RCMS490 Series Digital Multi-Channel Ground Fault Monitor / Ground Fault Relay Grounded and High-Resistance Grounded AC/DC Systems Technical Bulletin NAE1042060 / 04.2013 BENDER Inc.

More information

GS1 Parameter Summary Detailed Parameter Listings...4 9

GS1 Parameter Summary Detailed Parameter Listings...4 9 CHAPTER AC DRIVE 4 PARAMETERS Contents of this Chapter... GS1 Parameter Summary...............................4 2 Detailed Parameter Listings..............................4 9 Motor Parameters.........................................4

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

OPERATING INSTRUCTIONS FOR SYMCOM S INFORMER DIAGNOSTIC TOOL

OPERATING INSTRUCTIONS FOR SYMCOM S INFORMER DIAGNOSTIC TOOL OPERATING INSTRUCTIONS FOR SYMCOM S INFORMER DIAGNOSTIC TOOL INFORMER OPERATION The Informer is a handheld diagnostic tool for use with single-phase PumpSaver and PumpSaver Plus models equipped with infrared

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Operating Instructions for SymCom s INFORMER MS EDITION DIAGNOSTIC TOOL

Operating Instructions for SymCom s INFORMER MS EDITION DIAGNOSTIC TOOL Operating Instructions for SymCom s INFORMER MS EDITION DIAGNOSTIC TOOL INFORMER MS OPERATION The Informer MS is a handheld diagnostic tool designed for use with MotorSaver Model 455s equipped with infrared

More information

SECTION AUTOMATIC TRANSFER SWITCH

SECTION AUTOMATIC TRANSFER SWITCH SECTION 26 36 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, withstand and close-on ratings as shown on the plans.

More information

Generator Speed Controller Model GSC 1

Generator Speed Controller Model GSC 1 enerator Speed Controller odel SC 1 RA 29 977/09.95 Replaces: 4.92 Self contained controller for driving electrical power generators with a hydrostatic transmission 16 Bit microprocessor based controller

More information

RM-2000-RTDW Remote Monitor User s Guide

RM-2000-RTDW Remote Monitor User s Guide RM-2000-RTDW Remote Monitor User s Guide The RM-2000-RTDW motor-monitoring device can be used to monitor and/or control SymCom s Model 777 via an RS-485 Modbus network. Two form C output relays are available

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71 Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71 DPC71 PPC71 TRMS 3-phase over and under voltage, phase sequence, phase loss, asymmetry and tolerance monitoring relay Detect

More information

CONNECTIONS. TABLE 1: Wiring Configuration Based on Motor Amps. FIGURE 1: Typical Wiring Diagram

CONNECTIONS. TABLE 1: Wiring Configuration Based on Motor Amps. FIGURE 1: Typical Wiring Diagram INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-LR-TS ELECTRONIC OVERLOAD RELAY, 2-10 AMPS BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS

More information

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2 PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features

More information

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay Generator Differential Relay The MD3G Rotating Machine Differential Relay is a member of Cooper Power Systems Edison line of microprocessor based protective relays. The MD3G relay offers the following

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01 Product Description 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, over and

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller

More information

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart NK Technologies ADC series signal converters use sensor outputs (4 0 ma, 0 5 and 0 10 VDC) and convert these to digital RS485 outputs. The CTC series accept either 5 A secondary current from Analog to

More information

Protective Relays Digitrip 3000

Protective Relays Digitrip 3000 New Information Technical Data Effective: May 1999 Page 1 Applications Provides reliable 3-phase and ground overcurrent protection for all voltage levels. Primary feeder circuit protection Primary transformer

More information

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Installation and Operating Instructions. Power IT Power Factor Controller RVC Installation and Operating Instructions Power IT Power Factor Controller RVC Table of contents Page 1. Read this first... 3 About this Instruction Manual... 3 Safety... 3 Electromagnetic compatibility...

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

General Purpose Relays Types K, R, N, and C

General Purpose Relays Types K, R, N, and C General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in

More information

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase True RMS AC/DC Over and Under Current Types DIC0, PIC0 DIC0 PIC0 TRMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus

More information

Integra 1560 and 1580 Digital Transducer Systems

Integra 1560 and 1580 Digital Transducer Systems Integra 1560 and 1580 multi function transducers provide high accuracy

More information

PUMP & LEVEL CONTROLS UL/CANADIAN UL REC. OGNIZED \\\FEATURE MATRIX FIELD SELECTABLE SEQUENCING CSA CERTIFIED UL LISTED

PUMP & LEVEL CONTROLS UL/CANADIAN UL REC. OGNIZED \\\FEATURE MATRIX FIELD SELECTABLE SEQUENCING CSA CERTIFIED UL LISTED 800.727.5646 atcdiversified.com Diversified Electronics ARA, ARM Series PUMP & LEVEL S \\\ALTERNATING RELAYS The Alternating Relay is used in multiple load installations to assure equal run time on all

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 Monitoring Relays True RMS 3-Phase, 3-Phase+, Multifunction Types DPC01 Product Description 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, over and

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

Single Phase Soft Starters

Single Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (877) 304-0724

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

General Purpose Drives

General Purpose Drives AC Variable Speed Drive General Purpose Drives Dedicated to Low Power Applications 0.37kW 11kW / 0.5HP 15HP 200 480V 3 Phase Input AC Variable Speed Drive 0.37kW 11kW / 0.5HP 15HP 110 480V Single & 3 Phase

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives 3.0 50HP @ 200 to 240V AC 3.0 350HP @ 380 to 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum

More information

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED SECTION 16280 LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED PART 1 - GENERAL 1.1 SUMMARY This specification defines the requirements for active harmonic filter systems in order to meet IEEE-519-2014

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

UBZ-301 (63-630A) UNIVERSAL INDUCTION MOTOR PROTECTION UNIT

UBZ-301 (63-630A) UNIVERSAL INDUCTION MOTOR PROTECTION UNIT Ltd Intelligent industrial electronics UBZ-301 (63-630A) UNIVERSAL INDUCTION MOTOR PROTECTION UNIT OPERATING MANUAL Quality control system on the development and production complies with requirements ISO

More information

SUGGESTED SPECIFICATION DUAL OPERATOR OPEN TRANSITION AUTOMATIC TRANSFER SWITCH WITH RPTCS MICROPROCESSOR CONTROL

SUGGESTED SPECIFICATION DUAL OPERATOR OPEN TRANSITION AUTOMATIC TRANSFER SWITCH WITH RPTCS MICROPROCESSOR CONTROL TYPE RTS03ATB AUTOMATIC TRANSFER SWITCH RPTCS CONTROL EFFECTIVE 1/19/2011 SUGGESTED SPECIFICATION DUAL OPERATOR OPEN TRANSITION AUTOMATIC TRANSFER SWITCH WITH RPTCS MICROPROCESSOR CONTROL PART 1 - GENERAL

More information

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards The Solo, Select and Sync PWM boards provide a pulse-width modulated (PWM) signal to the EC motor to control fan speed.

More information

HPVFP High Performance Full Function Vector Frequency Inverter

HPVFP High Performance Full Function Vector Frequency Inverter Advanced User Manual HPVFP High Performance Full Function Vector Frequency Inverter HP VER 1.00 1. HPVFP Parameter Set Overview...3 1.1. About this section...3 1.2. Parameter Structure Overview...3 1.3.

More information

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards Buck-Boost 9 0 VA to 10 Applications n A comprehensive line of transformers for low voltage applications. n Economical for stepping voltages up or down n Solve over/under voltage problems efficiently n

More information

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General Section 16621A - AUTOMATIC TRANSFER SWITCH Part 1 General 1.01 One 600 Amp, 3 Phase, 480 Volt Automatic Transfer Switch (ATS) shall be provided with gasketed enclosure. The ATS shall consist of an inherently

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

67TD Series - Miniature Time Delay Relays DPDT, 4PDT, 5 Amp

67TD Series - Miniature Time Delay Relays DPDT, 4PDT, 5 Amp TD Series - Miniature Time Delay Relays DPDT, PDT, mp E When small size is a requirement series relays fit where others won t. The miniature ice cube timers are capable of handling up to amps. Typical

More information

MM2 STOP. MOTOR MANAGER 2 Instruction Manual. GE Industrial Systems

MM2 STOP. MOTOR MANAGER 2 Instruction Manual. GE Industrial Systems g GE Industrial Systems MM2 MOTOR MANAGER 2 Instruction Manual MM2 Firmware Revision: 5.2x MM2 Software Revision: 5.2x or newer Manual P/N: 1601-0056-DS (GEK-106294D) Copyright 2007 GE Multilin RUNNING

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12 INSTRUCTION MANUAL Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS Power Factor Controller A12 1. CONTENTS 1. CONTENTS 1 2. FEATURES 2 3. INSTALLATION, CONNECTION AND APPLYING POWER 2 4.

More information

Supplemental Motor Protection Devices Table of Contents

Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Bulletin 0S/S//... Page - Bulletin 0 Arcing Ground Fault Detection System: Adjustable Trip from A... Page -

More information

GENERAL PURPOSE RELAYS

GENERAL PURPOSE RELAYS CONTROL LOGIC GENERAL PURPOSE RELAYS GR c3controls offers a full line of General Purpose Relays ( plug-in relays), perfect for your control logic applications. Quick and economical to install, our relays

More information

Micrologic control units 2.0 E X Y Z. Overview of functions. Functions and characteristics

Micrologic control units 2.0 E X Y Z. Overview of functions. Functions and characteristics Overview of functions All Masterpact circuit breakers are equipped with a Micrologic control unit that can be changed on site. Control units are designed to protect Power circuits and loads. Alarms may

More information

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay Transformer Differential Relay The MD3T Transformer Differential Relay is a member of Cooper Power Systems Edison line of microprocessor based protective relays. The MD3T relay offers the following functions:

More information

E3 Adjustable Speed Drive Engineering Specification

E3 Adjustable Speed Drive Engineering Specification E3 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba E3 AC Variable Frequency Drives, 6 pulse for 230V and 460V. 1.1 References A. National

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

Variable Speed Brushed DC Motor Drive

Variable Speed Brushed DC Motor Drive The driving force of motor control & electronics cooling. Equinox: Variable Speed Brushed DC Motor Drive Navigator Equinox The Equinox variable speed brushed DC motor drive with Navigator Programmer is

More information

Installation and Operating Instructions

Installation and Operating Instructions Energy Division Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Our commitment. Your advantage. Contents Page 1 Introduction 4 1.1 Measurement Capabilities 5 1.2

More information

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01 Monitoring Relays 3-Phase Load Guard Types DWB0, PWB0 DWB0 PWB0 TRMS load guard relays for three phase balanced applications Measuring if the power factor is within set limits Measure voltage on own power

More information

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W Page 2 / 16 INDEX: GENERAL TYPES ACESSORIES AND OPTIONS INSTALLATION WIRING DIAGRAMS CONNECTING TERMINALS DIAGRAMS WIRING DIAGRAM DESCRIPTION WORKING DESCRIPTION AND KEYBOARD WORKING DESCRIPTION AND PROGRAMMING

More information

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control. Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)

More information

SECTION 4 TIME DELAY RELAYS 5 TO 13 AMPERES

SECTION 4 TIME DELAY RELAYS 5 TO 13 AMPERES Your Contact for Relays SECTION 4 TIME DELAY RELAYS 5 TO 3 AMPERES TDRPRO TIME DELAY RELAYS RELAY SERIES L.E.D. STATUS LAMP L W H..5 x.3 x 3.5 OR PIN OCTAL PLUG-IN L W H. x. x. OR PIN OCTAL PLUG-IN L W

More information

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications: Product Overview Providing users with powerful motor speed control in a compact, space saving design, the Allen-Bradley PowerFlex 4 and 40 AC drives are the smallest and most cost-effective members of

More information

Variable Frequency Drives

Variable Frequency Drives Table of Contents Variable Frequency Drives Product Product Code Resource Documents Page # Introduction F-3 SED2 154-042 F-5 with Conventional Bypass Option SED2 154-044 F-9 with Electronic (E) Bypass

More information

TOSVERT TM VF-nC3 Parameter List

TOSVERT TM VF-nC3 Parameter List TOSVERT TM VF-nC Parameter List E658664 - Setting information * Please fill it in if necessary. Item Content Item Content Setting date / person Customer Application Application model Motor manufacturer

More information

Inverter Drive /Vector Drive Motors & Controls

Inverter Drive /Vector Drive Motors & Controls H2 Inverter/ Encoderless Vector Inverter Drive /Vector Drive & Controls 3/4 thru 50 180-264 VAC 3 Phase - 50/60 Hz 3/4 thru 60 340-528 VAC 3 Phase - 50/60 Hz 3/4 thru 60 515-660 VAC 3 Phase - 60 Hz HVAC

More information

Multimeter 500CVD21 RTU500 series

Multimeter 500CVD21 RTU500 series Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase

More information

OVEN INDUSTRIES, INC. Model 5C7-362

OVEN INDUSTRIES, INC. Model 5C7-362 OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS

More information

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI General-purpose Relay CSM_GR-_-S_DS_E Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A

More information

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control s 1022/1025/1029C/1032/3629B 3629B Product Data Sheet s 1022/1025/1032 Single phase power controllers Current ratings from 10 to 70 Amps 1022-0 to 5VDC or pot input 1025-4 to 20 ma signal 1032 Current

More information

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web:  - Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996

More information