UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Size: px
Start display at page:

Download "UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49"

Transcription

1 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact housing dimensions (96x96 mm) With changeable option cards (only for TNM 3430 and TNM 3440) Description of the System The Celsa TNM Instruments are Panel mounted 96 X 96 mm DIN Square digital panel instruments for the measurement of various electrical parameters like Voltage, Current, Neutral Current, Frequency, Power, Energy, Energy Consumption, Phase angle, Import and Export kwh, KVA, kvah, Hour counter, On Hour, Phase sequence indication, Number of Interruptions. The instrument integrates accurate measurement with 3-line 4-digits ultra high brightness LED display. According to the number of parameters to be measure there are 4 different models of the TNM34xx-Series: No. C Features TNM 3410 TNM 3420 TNM 3430 TNM Number of parameters measured up to 18 up to 14 up to 48 up to On site programmable primary of PT/CT ratios 3. User selectable CT secondary: 5 A/ 1 A 4. User selectable PT secondary 5. User selectable. or 6. Neutral current measurement (For only) 7. Total system current demand & Total system current max. current demand 8. Total system kva demand & max. Total system kva demand 9. System kva 10. High brightness 3 line 4 digits LED display 11. Simple operation with easy to use front keys 12. Back scrolling of parameter screens 13. Parameter screen recall : In case of power failure, the instrument memorizes the last displayed screen. 14. Energy count storage :In case of power failure, the instrument memorizes the last energy count. 15. User selectable low current suppression (below 30 ma) 16. Min. Max storage of parameters possible 17. Optional pulse output (1 or 2 Relay output) 18. Limits switch for pulse output 19. Optional MODBUS (RS 485) Output 20. Configuration of the instrument via MODBUS 21. Optional Analog Outputs (1 or 2 outputs) 22. Enclosure Protection for dust & water Conforms to IP 54 (front face) as per IEC Compliance to international safety standards 24. EMC compatibility - IEC Onsite adjustable display update time 26. Active Energy measurement (kwhr Import/ Export) 27. Energy measurement (Import/ Export) 28. Total Harmonic Distortion (THD) 29. Phase reversal indication 1/49

2 Technical Specifications Input Voltage Ampere Hour (For TNM 3440) Nominal input voltage (AC RMS) Phase - Neutral V L-N, Default pulse rate CT Secondary = 1A Max pulse rate 3600 pulses/ Ah* Line - Line V L-L divisors CT Secondary = 5A Max pulse rate 720 pulses/ Ah Max. continuous Input voltage 120% of rated value Other Pulse rate divisors Input Current 10 CT Secondary = 1A Max pulse rate 3600 pulses/ 10Ah* Nominal input Current 1 or 5 A AC RMS (Programmable on site) CT Secondary = 5A Max pulse rate 720 pulses/ 10Ah System CT Primary values std. values upto 4kA (1 or 5 Amp.) (for 3410 & 3420) 100 CT Secondary = 1A Max pulse rate 3600 pulses/ 100Ah* std. values upto 9999A (1 or 5 Amp.) (for 3430 & 3440) CT Secondary = 5A Max pulse rate 720 pulses/ 100Ah Max. continuous Input Current 120% of rated value 1000 CT Secondary = 1A Max pulse rate 3600 pulses/ 1000Ah* Total Harmonic Distortion Up to 15th Harmonics 0% - 50% (for 3430 & 3440) CT Secondary = 5A Max pulse rate 720 pulses/ 1000Ah Auxiliary Supply Pulse duration 60 ms, 100 ms or 200 ms AC Auxiliary Supply 110 V AC-15% / +20%/ 230V AC - 15%/+20%/ *No. of Pulses = Maximum Pulses 380V AC-15%/+20 CT ratio AC Auxiliary Supply frequency range 45 to 66 Hz Where, CT Ratio = (CT primary / CT Secondary) VA Burden Limit Output Option (For TNM 3440) Nominal input Voltage burden < 0.2 VA approx. per phase Nominal input Current burden < 0.6 VA approx. per phase Limit can be assigned to different measured parameters. It can be configured in one of the four AC Supply burden (for 3410 & 3420) 4 VA modes given below. Auxiliary Supply burden < 4 VA approx. or < 5 VA approx. (for 3430 & 3440) with 4-20mA analog output option 1) Hi alarm & Energized Relay Overload withstand 2) Hi alarm & De - Energized Relay 3) Lo alarm & Energized Relay Voltage 2x rated value for 1 sec. 4) Lo alarm & De - Energized Relay repeated 10 times at 10 sec. intervals Current 20x rated value for 1 sec. With user selectable trip point, Hysteresis, Energizing delay and De - energizing delay. repeated 5 times at 5 min. Power Factor (for 3420,3430 & 3440) 0.5 Lag Lag Operating Measuring Ranges PT Secondary Ranges for Various Input Voltage (For TNM 3440) Voltage Current Frequency Reference conditions for Accuracy % of rated value % of rated value Hz Ref. Temperature 23ºC +/- 2ºC Input waveform Sinusoidal (distortion factor 0.005) Input Frequency 50 or 60 Hz +/- 2% Auxiliary Supply Voltage Rated value +/- 1% Auxiliary Supply Frequency Rated value +/- 1% Power Factor cosɸ / sinɸ = 1 for active/ reactive Accuracy Voltage +/- 0.5% of range ( % of rated value) Current +/- 0.5% of range ( % of rated value) Frequency 0.15% of mid frequency System Apparent Power (VA) (for 3410) +/- 0.5% of range ( % of rated value) Neutral Current (for 3410) (only ) +/- 4% of range ( % of rated value) Active energy (kwh) (for 3420) 1% (IEC ) Active P.F lag lag Active energy (kwh) (for 3430 & 3440) 1% (IEC ) Active Power (for 3430 & 3440) +/- 0.5% of range ( % of rated value) Re-Active Power (for 3430 & 3440) +/- 0.5% of range ( % of rated value) Apparent Power (for 3430 & 3440) +/- 0.5% of range ( % of rated value) Re-Active energy KVArh (for 3430 & 3440) +/- 0.5% Apparent energy (for 3430 & 3440) +/- 0.5% Accuracy of Analog Output (for 3430 & 3440) 1% of Output end value Power Factor (for 3430 & 3440) +/- 0.5% of range Phase angle 1% of range Total Harmonic Distortion +/- 1% Influence of variations Temperature coefficient (For rated value 0.025%/0C for Voltage ( % of rated value) and range of use ºC) 0.05%/0C for Current ( % of rated value) Display updates rate Response time to step input 1 sec. approx. Applicable Standard EMC IEC Immunity IEC V/ m min - Level 3 industrial low level Safety IP for water & dust IEC Pollution degree 2 Installation category CAT III High Voltage test 2.2 kv AC, 50Hz for 1 min. between all electrical circuits Environmental Operating temperature -10 to +55ºC Storage temperature -20 to +65ºC Relative Humidity % non condensing Warm up time Minimum 3 min. Shock 15g in 3 planes Vibration Hz, 0.15 mm amplitude Pulsed Output Optional For TNM 3420, 3430 and 3440 Input Voltage 110V L-L (63.5V L-N) 230V L-L (133V L-N) 415V L-L (239.6V L-N) PT Secondary settable Range 100V - 120V L-L (57 V - 69 V L-N) 121V - 239V L-L (70V - 139V L-N) 240V - 480V L-L (140V - 277V L-N) Changeable option cards available for TNM 3430 / TNM 3440 Energy (Can be programmed for different energy parameters simultaneously) Relay contact 1 No + 1 NC Switching Voltage & Current for Relay 240 VDC, 5 A Default pulse rate divisors 1 per Wh (up to 3600W), 1 per kwh (up to 3600kW), 1 per MWh (up to 3600kW), UNIVERSAL INSTRUMENTS 01 Other Pulse rate divisors 10 1 per 10 Wh (up to 3600W), 1 per 10kWh (up to 3600kW), 1 per 10MWh (up to 3600 kw), per 100 Wh (up to 3600W), 1 per 100kWh (up to 3600kW) 1 per 100MWh (up to 3600 kw), per 1000 Wh (up to 3600W), 1 per 1000kWh (up to 3600kW), 1 per 1000MWh (up to 3600 kw), Pulse duration 60 ms, 100 ms ot 200 ms Above options are also applicable to Apparent & reactive Energy (For TNM 3430 & 3440) 1/50

3 No. Parameter TNM 3410 TNM 3420 TNM 3430 TNM System Voltage 2. System Current 3. Voltage L1 - N 4. Voltage L2 - N 5. Voltage L3 - N 6. Voltage L1 - L2 7. Voltage L2 - L3 8. Voltage L3 - L1 9. Current L1 10. Current L2 11. Current L3 12. Neutral Current 13. Frequency 14. System Active Power (kw) 15. Active Power L1 (kw) 16. Active Power L2 (kw) 17. Active Power L3 (kw) 18. System Re - Active Power (kvar) 19. Re - Active Power L1 (KVAr) 20. Re - Active Power L2 (KVAr) 21. Re - Active Power L3 (KVAr) 22. System Apparent Power (kva) 23. Apparent Power L1 (kva) 24. Apparent Power L2 (kva) 25. Apparent Power L3 (kva) 26. System Power Factor 27. Power Factor L1 28. Power Factor L2 29. Power Factor L3 30. Phase Angle L1 1/51

4 No. Parameter TNM 3410 TNM 3420 TNM 3430 TNM Phase Angle L2 32. Phase Angle L3 33. Import & Export kwh (8 digit resolution) 34. Import & Export kvarh (8 digit resolution) UNIVERSAL INSTRUMENTS kvah (8 digit resolution) 36. kah (8 digit resolution) 37. Current demand 38. KVA Demand 39. KW Import Demand 40. KW Export Demand 41. Max Current Demand 42. Max KVA Demand 43. Max KW Import Demand 44. Max KW Export Demand 45. Run Hour 46. On Hour 47. Number of Interruptions 48. Phase Reversal Indication 49 Total System & Max. Current Demand 50. Total System & Max. KVA Demand 51. THD Volts L1 - N 52. THD Volts L2 - N 53. THD Volts L3 - N 54. THD Volts L1 - L2 55. THD Volts L2 - L3 56 THD Volts L3 - L1 57. THD Current L1 59 THD Current L2 59. THD Current L3 60. THD Volts Mean 61. THD Current Mean 1/52

5 Connections diagrams: It is recommend that the wires used for connections to the instrument should have lugs soldered at the end. That is, the connections should be made with Lugged wires for secure connections. The maximum diameter of the lug should be 0.7mm abd maximum thickness 3.5mm. Permissible cross section of the connection wire: <= 4mm 2 single wire or 2x 2.5mm 2 fine wire. Dimensions: 96 mm 80 mm 92mm mm Display Area 92mm +0.8 Panel Cutout 1/53

6 Ordering Information Ordering Code TNM 3410 TNM 3420 TNM 3430 TNM 3440 System Type (Connection network) 3 Phase (programmable as 4wire or 3wire on site) Phase Input Current programmable as 5 A or 1 a on site Programmable Programmable Programmable Programmable Input Voltage 110 V L-L (63.5V L-N) V L-L (133V L-N) V L-L (239.6V L-N) V L-L (254V L-N) AC Auxiliary Voltage 110 V AC -15% / +20% L L L Not Available Not Available 230 V AC -15% / +20% M M M Not Available Not Available 380 V AC -15% / +20% H H H H H 100 V V AC DC -10% / +10% AD AD Not Available AD AD 12 V V AC DC -10% / +10% D D Not Available D D Optional: MODBUS (RS 485) MODBUS (RS485) output R Not Available Not Available R R MODBUS Option not used Z Not Available Not Available Z Z Optional: Pulse Output for energy measurement 1 Pulse output S Not Available S S S 2 Pulse output D Not Available D D D Pulse output option not used Z Not Available Z Z Z Optional: Analog outputs 2 Outputs (0-1 ma DC each) 1 Not Available Not Available Outputs (4-20 ma DC each) 2 Not Available Not Available 2 2 Analog output option not used Z Not Available Not Available Z Z Ordering example: 1. Celsa TNM M 2. Celsa TNM M - D 3. Celsa TNM AD - R - S Celsa TNM M - R - S - 2 UNIVERSAL INSTRUMENTS 01 Auxiliary Supply Ranges Availability of Auxiliary Supply Type 110, 230, 380 V AC V AC/DC V DC Pulse Pulse Pulse Pulse RS Analog output Pulse + RS Pulse + 2 Analog output Pulse + RS RS Analog output RS Pulse + 2 Analog output Pulse (1 limit) Pulse (1 limit) RS Analog output Pulse (1 limit) + RS Pulse (1 limit) + 2 Analog output Pulse (2 limit) + RS RS Analog output RS Pulse (1 limit) + 2 Analog output 1/54

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features: Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy

More information

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet AMIK 300 / 301 USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. Special Features Pulse/Limit Switch output (optional) Number of interruption Application

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary Application: Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwor & replaces the multiple analog panel meters. t measures electrical parameters lie AC current,, frequency,

More information

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has

More information

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

Alpha 50. Technical Data Sheet. Special Features

Alpha 50. Technical Data Sheet. Special Features Technical ata Sheet lpha 50 lpha 50 is a compact multifunction instrument with touch screen LC utility which measures important electrical parameters in 3 phase and single phase Network & replaces the

More information

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet ISH Delta Energy / Demand (Multifunction instrument) Data Sheet www.rishabh.co.in Page 1 of 6 Version: D 14 / 03 / 2012 Application: ISH Delta Energy measures important electrical parameters in 3 phase

More information

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet Datasheet Article No: 136-5385 Digital AC Ammeter, 48x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5387 Digital AC Ammeter, 96x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5388 Digital

More information

Jewell DPM EINE BEST IN CLASS

Jewell DPM EINE BEST IN CLASS Application: Silent Features: The digital panel meter has been designed Fast & Easy installation on panel with the for industrial applications, which help of external swivel screws. frequently require

More information

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet Datasheet ENGLISH Article No: 136-5390 Digital AC Ammeter, 48x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5391 Digital AC Ammeter, 96x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5393

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

AMIK Three Phase Digital Panel Meters

AMIK Three Phase Digital Panel Meters AMIK Three Phase Digital Panel Meters USA SICE 1936 ELIAILIT EOD MEASUE Special Features 3 Line 4 Digits ultra bright LED Display (up to 9999) On site Programmable CT/PT atios User selectable CT Secondary

More information

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay Technical Datasheet RELAY-1 RELAY-2 k V Hz RESET ABH TEST True RMS Measurement True RMS Digital Protection V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,

More information

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay Technical Datasheet RELAY-1 RISHABH k V RESET True RMS Digital Protection Relay RELAY-2 TEST True RMS Measurement RISH Relay V is used to protect against Over Voltage, Under Voltage, Phase Sequence detection,

More information

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay Line Monitoring Technical Datasheet RISH RELAY-1 RELAY-2 RISHABH k V Hz True RMS Digital Protection RISH V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,

More information

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID Professionally approved products. Datasheet Stock Number: 144-0527 3 Phase Multi-function Power Meter 1/5A MID 96mm² Panel Mounted Power Meter. MID UK Specifications The 144-0527 is a new generation modern

More information

Integra 1560 and 1580 Digital Transducer Systems

Integra 1560 and 1580 Digital Transducer Systems Integra 1560 and 1580 multi function transducers provide high accuracy

More information

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.

More information

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2 PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

Centrale de mesure Power Meter PM500 Merlin Gerin

Centrale de mesure Power Meter PM500 Merlin Gerin Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with

More information

Ziegler EM 1320/30/40

Ziegler EM 1320/30/40 Ziegler EM 1320/30/40 Operating Manual Ziegler EM 1340 2-60-006-00-00483_Rev. C - 9/2014 www.ziegler-instruments.com 1 36 DIGITAL MULTIFUNCTION INSTRUMENT Programmable Multi-function Energy Meter Installation

More information

Operating Guide October 2006

Operating Guide October 2006 Operating Guide October 2006 Safety 1 Safety This manual represents your meter as manufactured at the time of publication. It assumes standard software. Special versions of software may be fitted, in which

More information

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014 Operating Manual RISH EM 1320/30/40 1 2-60-006-00-00483_Rev. C - 9/2014 2 DIGITAL MULTIFUNCTION INSTRUMENT Programmable Multi-function Energy Meter Installation & Operating Instructions Section Contents

More information

RISH Master 3440i/3440iDL 0.2S

RISH Master 3440i/3440iDL 0.2S Operating Manual RISH Master 3440i/3440iDL 0.2S as per IEC62053-22 Touch Screen Digital Multi-Function Meter Installation & Operating Instructions Section Contents 1. Introduction INDEX 2. Measurement

More information

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID RIF300 Series easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer input with TASSCTEWA module)

More information

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters

More information

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter Telephone : 44 (0) 1245 428500 PRELIMIARY DATA SHEET RIF400 Series easywire Single and Three Phase Multifunction Energy Meter DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

MultiCube Multi-Function Electricity Meter. Installation and Operation

MultiCube Multi-Function Electricity Meter. Installation and Operation MultiCube Multi-Function Electricity Meter Installation and Operation PREFACE MultiCube Operating Guide Revision 1.08 Jan 2007 This manual represents your meter as manufactured at the time of publication.

More information

Application: Salient Features: Products Features:

Application: Salient Features: Products Features: PHSE PRGRMME RISH PG / PGV pplication: The digital panel meters RISH have been designed for industrial applications, which frequently require precise and onsite adjustment of the display range. It can

More information

Programmable DPM RISH EINE

Programmable DPM RISH EINE Programmable PM RISH EIE ata Sheet www.rishabh.co.in Page 1 of 5 pplication : The digital panel meters RISH Eine PM have been designed for industrial applications, which frequently require precise and

More information

MT 560/UMT TRANSDUCER & ANALYZER

MT 560/UMT TRANSDUCER & ANALYZER MT 560/UMT 560 - TRANSDUCER & ANALYZER USE The MT 560/UMT 560 multi transducer and analyzer is used for a permanent analysis of electricity supply quality in compliance with the SIST EN 50160 standard.

More information

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL GIMA Multi-Function Electricity Meter OPERATOR S MANUAL SIMPSON ELECTRIC COMPANY 520 Simpson Avenue Lac du Flambeau, WI 54538 715-588-3311 FAX: 715-588-7930 Printed in U.S.A. Part No. 06-117285, Edition

More information

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID Telephone : 44 (0) 1245 428500 RIF300 Series MID easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 1A Input from easywire CTs Single phase or three phase network

More information

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM] Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

ULTRA RAPID POWER QUALITY ANALYZER

ULTRA RAPID POWER QUALITY ANALYZER ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with

More information

Contents. Introduction and description Package contents Device identification PM Options... 80

Contents. Introduction and description Package contents Device identification PM Options... 80 Contents 1 Introduction and description Package contents... 77 Device identification... 77 2 Characteristics PM500... 78 Options... 80 3 Installation Front-panel cut-out... 82 Mounting... 82 4 Connections

More information

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time

More information

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN Energy Management Energy Analyzer Type EM11 DIN Other versions available (not certified, option X): see how to order on the next page Product Description Class 1 (kwh) according to EN62053-21 Class B (kwh)

More information

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),

More information

DM-III Multitest & DM-III Multitest F Power Quality Recorders

DM-III Multitest & DM-III Multitest F Power Quality Recorders DM-III Multitest & DM-III Multitest F Power Quality Recorders CAT 600V TRUE RMSz Amprobe s full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to

More information

PEM353. Universal measuring device

PEM353. Universal measuring device 353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities

More information

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications. Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

Monitoring Electric Network Via Internet

Monitoring Electric Network Via Internet Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording

More information

Energy Division

Energy Division Energy Division http://energy.tycoelectronics.com Installation and Operating Manual Integra 1560 and 1580 Digital Metering and Transducer Systems Tyco Electronics UK Limited Crompton Instruments Freebournes

More information

Installation and Operating Instructions

Installation and Operating Instructions Energy Division Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Our commitment. Your advantage. Contents Page 1 Introduction 4 1.1 Measurement Capabilities 5 1.2

More information

Power Meter Series PM3200 Functions and characteristics

Power Meter Series PM3200 Functions and characteristics Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring

More information

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required

More information

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN Energy Management Energy Meter Type EM23 DIN Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X): see how to order on the next

More information

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems

Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Tyco Electronics UK Limited Crompton Instruments Freebournes Road, Witham, Essex, CM8 3AH, UK Tel: +44 1376 509 509

More information

N30P DIGITAL PANEL METER

N30P DIGITAL PANEL METER N30P DIGITAL PANEL METER Features: NEW Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cosj, tgj, j, frequency, active, reactive and apparent energy,

More information

Conzerv EM6400NG series

Conzerv EM6400NG series Conzerv EM6400NG series Multi-function power & energy meters Technical datasheet PB115131 Introducing EM6400NG, next generation power meters of iconic EM6400 series with innovative Accurate measurements

More information

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

Electrical network management. Schneider Electric. PM3200 Technical Datasheet Electrical network management Schneider Electric PM3200 Technical Datasheet Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact

More information

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

Technical Datasheet. Delta Power 1000A / 400A AC-DC

Technical Datasheet. Delta Power 1000A / 400A AC-DC Delta 1000A / 400A AC-DC Technical Datasheet Delta 1000A/ 400A AC-DC is specially designed for Measurement of AC-DC POWER and quality parameters. Up to 49th Individual Harmonics Non contact voltage detection.

More information

DM-III MULTITEST Power Quality Recorder

DM-III MULTITEST Power Quality Recorder DM-III MULTITEST Power Quality Recorder Amprobe s full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to operate accurately and effectively in today

More information

METRAClip87 and 88 Clamp Multimeters

METRAClip87 and 88 Clamp Multimeters 3-349-795-03 1/7.14 Current and frequency measurement via clamp meter: METRAClip87: 1500 A AC TRMS and 1500 A DC METRAClip88: 2000 A AC TRMS and 3000 A DC Multimeter functions via connector sockets: V

More information

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SUPPLY NETWORK ANALYZER CVM-96 SERIES SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY

More information

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT

More information

UMG 96RM Basic Device

UMG 96RM Basic Device Smart Energy & Power Quality Solutions Power Analyser Basic Device Data sheet Dok.-Nr. 2.040.172.0 02/2019 DEVICE VIEWS Front view Rear view Side view Bottom view max. 6 96 91,5 104 91,5 97 42 Cut-out

More information

Metering Devices, Protective Relays, Software and Connectivity

Metering Devices, Protective Relays, Software and Connectivity , Protective Relays, Software and Connectivity.3 IQ Analyzer 6400/6600 Series IQ Analyzer Comprehensive Electrical Distribution Monitoring IQ Analyzer 6400/6600 Series Product Description Eaton s IQ Analyzer

More information

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft Energy Management Power Analyzer ype WM-DI Basic Version Optional dual pulse output Alarms (visual only) V L, An Optional galvanically insulated measuring inputs Product Description ype Selection Range

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

UPM209 1/5A CT, 80A Multifunction three-phase meter

UPM209 1/5A CT, 80A Multifunction three-phase meter 1/5A CT, 80A Multifunction three-phase meter 4 DIN modules compact version Fully bi-directional four quadrants measurements for all energies and powers Main electrical parameters measured and displayed

More information

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5. Harmonics GridVis Analysis software Modbus interface Measurement accuracy 0.5 Universal measurement device for DIN rails Communication Protocols: Modbus RTU / Slave Interface RS485 Power quality Harmonics

More information

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type

More information

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

Introduction DIN rail mounted electricity meters

Introduction DIN rail mounted electricity meters Introduction DIN rail mounted electricity meters Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail

More information

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485 cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase

More information

Energy Division

Energy Division Energy Division http://energy.tycoelectronics.com Installation and Operating Manual Integra 1560 and 1580 Digital Metering and Transducer Systems Tyco Electronics UK Limited Crompton Instruments Freebournes

More information

Energy counting and measurement

Energy counting and measurement Energy counting In the current context of research of energy saving, counting of consumption become unavoidable. Hager offers new residential and tertiary solutions, to better control energy consumption.

More information

Data Sheet. Earth Leakage Relay RISH ELR/ELR+/ELR VI/ELR VI(NE) A V RISH ELR VI. Record. Digital Protection Relay RESET TEST ENTER

Data Sheet. Earth Leakage Relay RISH ELR/ELR+/ELR VI/ELR VI(NE) A V RISH ELR VI. Record. Digital Protection Relay RESET TEST ENTER ata Sheet arth eakage Relay RISH R/R+/R VI/R VI() RISH R VI 8.8. 8. 8. V R-1 R-2 igital Protection Relay K RST TST TR nalyze ata Sheet arth eakage Relay RISH R RISH arth eakage Relay is used to etect and

More information

Energy Management Modular Power Analyzers Type WM2-96

Energy Management Modular Power Analyzers Type WM2-96 ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer

More information

OPERATING MANUAL Rish Eine. Size: 48 x 96 Size: 96 x 96

OPERATING MANUAL Rish Eine. Size: 48 x 96 Size: 96 x 96 PERTING MNU Rish Eine Size: 48 x 96 Size: 96 x 96 MN-00IM-0637 Rev_B 12/2017 Rish Eine PRGRMMBE PM / C olt Meter (3 Φ) : Eine - 3 C mmeter (3 Φ) : Eine - 3 C olt Meter (1 Φ) : Eine - C mmeter (1 Φ) : Eine

More information

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management Modular Smart Power Transducer Type SPT-90 Energy Management Modular Smart Power Transducer Type SPT-90 Class 0.5 (current/voltage) 16-bit µp-based modular smart power transducer Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among

More information

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD.

PMAC770 Multifunction Power Meter. Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. PMAC770 Multifunction Power Meter Installation & Operation Manual V2.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals. The manufacturer shall not

More information

Multimeter 500CVD21 RTU500 series

Multimeter 500CVD21 RTU500 series Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase

More information

Digital Multifunction Meter - RISH Integra 2000

Digital Multifunction Meter - RISH Integra 2000 Features Four line graphic LCD display 1+ parameters Fast communications Customer configurable Easy to use Output options: 4 x -1mA 4 x 4-2mA 1 or 2 energy pulses Panel mounted Neutral current measurement

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96 Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS ASCII Communications Protocol REFERENCE GUIDE Every effort has been made to ensure that the material herein is complete and accurate. However, the

More information

EM-72 Electricity Meters for Current Transformers

EM-72 Electricity Meters for Current Transformers Product sheet MT8.18 Meter EM72 EM-72 Electricity Meters for Current Transformers EM72 electricty meters have been designed for panel mounting to monitor electricity consumption and the quality of the

More information

RISH ELR Earth Leakage Relay Preliminary Datasheet True RMS Measurement Trip relay cum DPM CBCT Open Detection 4 digit 7 segment LED display

RISH ELR Earth Leakage Relay Preliminary Datasheet True RMS Measurement Trip relay cum DPM CBCT Open Detection 4 digit 7 segment LED display RISH R arth eakage Relay Preliminary atasheet Technical atasheet RISH R RISH arth eakage Relay is used to etect and protect instruments from leakage current. RISH R VI RISH R VI RISH R VI is used to protect

More information

Energy Management Energy Analyzer Type EM210 MID

Energy Management Energy Analyzer Type EM210 MID Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3

More information

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters. cat iii Electrical Safety N100 - power network analyzer Measurement of power network parameters in 3 or 4-wire, balanced or unbalanced systems. two-color led display (red, green). Four quadrant energy

More information