Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
|
|
- James Bailey
- 6 years ago
- Views:
Transcription
1 Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current = 10 (I th ) Suitable for electronic devices (DIN 19240) Finger proof (BG 2) ccessories 2- and 4-pole additional auxiliary contacts in different configurations pproved Standards Standard Guide No (US,C) UL NKCR, NKCR7 IEC see page 95 DE 0660 EN Ordering Information Model Legend 1. Mini Contactor Relays J7KN-##-##-##### ) Mini Contactor 2) R: Contactor Relay 3) Combination of NO / NC contacts 22: 2 NO 2 NC 31: 3 NO 1NC 40: 4 NO 0NC 4) Coil voltage (C operated) 24: C24 50/60Hz 48: C48 50Hz 110: C Hz,C Hz 230: C Hz,C240 60Hz 240: C Hz 400: C Hz,C440 60Hz 415: C Hz 550: C Hz,C600 60Hz Coil voltage (DC operated) 24D: DC24 48D: DC48 60D: DC60 110D: DC D: DC125 24S: DC24 with diode 48S: DC48 with diode 110S: DC110 with diode 125S: DC125 with diode 2. ux. Contact Modules for Mini Motor Contactor Relays J73KN-##-##-# ) uxiliary Contact Modules 2) : for i contactor relays 3) Combination of NO/NC contacts 11: 1 NO 1 NC 02: 0 NO 2 NC 22: 2 NO 2 NC 40: 4 NO 0 NC Mini Contactor Relays 4-pole J7KN-R 7
2 System overview Mini Contactor Relays 4-pole C Operated Contacts Distinc. Ratings Thermal Rated Current I th Type Pack Coil voltage 1) 24 50/60Hz Hz Weight C NO NC 230 pcs. kg/pc. 4-40E J7KN-R ,16 J7KN-R E J7KN-R ,16 J7KN-R E J7KN-R ,16 J7KN-R ) Other coil voltages see page 10 DC Solenoid Operated Contacts Distinc. Ratings C15 Thermal Rated Current Type Pack Weight NO NC I th Coil voltage 24 DC 2,5W pcs. kg/pc. 4-40E J7KN-R-40 24D (-S) 1) 10 0, E J7KN-R-31 24D (-S) 1) 10 0, E J7KN-R-22 24D (-S) 1) 10 0,19 1) with built-in coil suppressor (diode + zener diode) uxiliary Contact Blocks for Contactor Relays J7KN-R Contacts Ratings C15 Thermal Rated Current Type Pack Weight NO NC I th pcs. kg/pc J73KN , J73KN , J73KN , J73KN ,04 8 Mini Contactor Relays 4-pole J7KN-R
3 System overview Mini Contactor Relays 4-pole C Operated Wiring Diagrams Distinc. uxiliary Contact Blocks Contactor Relay with uxiliary Contact Contacts suitable for Electronic Block Distinc. according to Circuits according to DIN for rated voltage 24 DC (test ratings 17 DC, 5m) Type NO NC NO NC Mirror contacts 40E J73KN E 5 1 Preferable combinations with J73KN E 4 2 distinctive letter E according to J73KN E 8 0 J73KN E E J73KN Y 4 2 J73KN Y 3 3 J73KN Y 7 1 J73KN Y E J73KN Y 3 3 J73KN Y 2 4 J73KN Y 6 2 J73KN Y 4 4 DC Solenoid Operated Wiring Diagrams Distinc. uxiliary Contact Blocks Type NO NC Contactor Relay with uxiliary Contact Block Distinc. according to NO NC 40E J73KN E 5 1 Preferable combinations with J73KN E 4 2 distinctive letter E according to J73KN E 8 0 J73KN E E J73KN Y 4 2 J73KN Y 3 3 J73KN Y 7 1 J73KN Y E J73KN Y 3 3 J73KN Y 2 4 J73KN Y 6 2 J73KN Y 4 4 uxiliary Contact Blocks for Contactor Relays J7KN-R Wiring diagrams J73KN--11 J73KN--02 J73KN--40 J73KN--22 Contacts suitable for Electronic Circuits according to DIN for rated voltage 24 DC (test ratings 17 DC, 5m) Mirror contacts Mini Contactor Relays 4-pole J7KN-R 9
4 Specifications Coil oltages Suffix oltage Marking Rated Control oltage U s range for to contactor type e.g. at the coil 50Hz 60Hz J7KN-R for 50Hz for 60Hz Suffix oltage Marking Rated Control oltage U s range for to contactor type e.g. at the coil 50Hz 60Hz J7KN-R for 50Hz for 60Hz Standard voltages in bold type letters. Coil not exchangeable 10 Mini Contactor Relays 4-pole J7KN-R
5 Engineering data and Characteristics Mini Contactor Relays Data according to IEC , DE 0660, EN C DC DC + Diode uxiliary Contacts Type J7KN-R... J7KN-R...D J7KN-R...S J73KN-... Rated insulation voltage U i C 690 *1 690 *1 690 *1 690 *1 Thermal rated current I th to 690 mbient temperature 40 C C Power loss per pole at I th W Utilization category C15 Rated operational current I e Utilization category DC13 Rated operational current I e Maximum ambient temperature Operation open C -40 to +60 (+90) *2 enclosed C -40 to +40 Storage C -40 to +90 Short circuit protection short-circuit current 1k, contact welding not accepted. fuse size gl (gg) Power consumption of coils C operated inrush sealed W DC operated inrush W sealed W Operation range of coils in multiples of control voltage U s Switching time at control voltage U s ±10% *3,*4 C operated make time ms release time ms arc duration ms DC operated make time ms release time ms arc duration ms Cable cross-section all connectors solid mm² flexible mm² flexible with multicore cable end mm² Clamps per pole solid or stranded WG *1) Suitable at 690 for: earthed-neutral systems, overvoltage category I to I, pollution degree 3 (standard-industry): U imp = 8k Data for other conditions on request. *2) With reduced control voltage range 0.9 up to 1.0 x U s and with reduced thermal rated current I th to I e /C15 *3) Summary switching time = release time + arc duration *4) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (aristor, RC-units, Diode units). Mini Contactor Relays 4-pole J7KN-R 11
6 Mini Contactor Relays for North merica Data according to UL508 Main Contacts (culus) Type J7KN-R... J73KN-... Rated operational current "General Use" Rated operational power of three-phase motors 115 hp - - at 60Hz (3ph) 200 hp hp hp hp - - Rated operational power of of C motors 115 hp - - at 60Hz (1ph) 200 hp hp - - Fuses - - Suitable for use on a capability of delivering not more than rms Rated voltage C uxiliary Contacts (culus) heavy pilot duty C standard pilot duty DC Q600 Q600 Dimensions C and DC operated with screw terals J7KN-R... uxiliary Contact Blocks J73KN-... Do not use/install these products before having read the applicable precautions as listed in Cat. No. J09-EN-01 available from or on request from OMRON local sales office. LL DIMENSIONS SHOWN RE IN MILLIMETERS. Cat. No. J04E-EN-01 In the interest of product improvement, specifications are subject to change without notice. 12 Mini Contactor Relays 4-pole J7KN-R
Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More informationMicro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13
Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC
More informationIndex. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6
Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram
More informationCapacitor Switching Contactors
Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..
More informationGeneral 2 Approvals 3 Technical Information 5 Mounting Information 6
Index Page General 2 Approvals 3 Technical Information 5 Mounting Information 6 Mini Contactors 7 Mini Contactors 8 Interface Contactors 8 Mini Reversing Contactors 4 Technical Information 5 Dimensions
More informationOutput of three-phase motors at 50 Hz and 400 V
RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements
More informationMicro-Contactors LAM ONLINE SHOPPING! Get Ready. Get Schrack. In the office and on the go with the Live Phone App.
Micro-Contactors LAM The contactor, as small as a relay the smallest in the world 3mm contact clearance acc. IEC60335-1 for safety-related applications Reversing contactors with mechanical interlock ONLINE
More informationGeneral Catalogue. Quality made in D946E182
General Catalogue Quality made in D946E182 Index Page Contactors, Motor-Starter (D677E) 3 Micro Contactors 11 Mini Contactors 25 Contactor Relays 39 Contactors 45 Starters 91 D.O.L. Starters 111 Overload
More informationIndustrial Controls. Catalog IC SIRIUS. Answers for industry.
Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor
More informationThe CWC0 compact contactors are offered as a complete solution for switching and controlling motors.
Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application
More informationDescription Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module
DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA
More informationLC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil
Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC2D09BL REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationUtilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms
controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More informationType: DILEM 10 G(24VDC) Article No.:
Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220
More informationDescription Basic devices with positive operation contacts
Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILA-31(24VDC) Articleno. 276379 CatalogNo. XTRE10B31TD Deliveryprogramme Product range DILA relays Application Contactor relays Description Basic devices with
More informationLC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationContactors and Contactor Assemblies
s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation
More information3RH1 contactor relays, 4- and 8-pole
Siemens AG 2010 RH, TH Contactor Relays RH1 contactor relays, 4- and 8-pole Overview AC and DC operation IEC 60947, EN 60947. The RH1 contactor relays are suitable for use in any climate. They are finger-safe
More informationType: DILEM 10(220V50HZ,240V60HZ) Article No.:
Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230
More informationLC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil
Product data sheet Characteristics LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 -
More informationCharacteristics 5 TeSys k contactors and reversing contactors
90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to
More informationAC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.
Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and
More informationLC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition
Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition
More informationFor non-electrical quantities
Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data
More informationLow profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b
Low profile safety relay with forcibly guided double contacts SFN4D RELAY 3.3 33.0 FEATURES Relay complies with EN 020, Type B. Polarized magnet system with snap action function Tolerance ±0.3 mm Weight
More informationType: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information
Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationType: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information
Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationSwitches Unlimited Contact: Phone: Fax:
Phone: 8--87 Fax: 78-67-67 - C Coil Three Pole - Series C7 C7 Non-Reversing, Three Pole With C Coil, Series C7 (Open type only) [] Ratings for Switching C Motors (C / C / C) kw (5 Hz) UL/CS HP (6 Hz) uxiliary
More informationOFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category
Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide
More informationLC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil
Product data sheet Characteristics LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 -
More informationShort-circuit-proof switching amplifier for inductive loads up to 10 A
MICROOPTO Overview Short-circuit-proof switching amplifier for inductive loads up to 10 Powerful, compact solid-state relay with error signalling contact The MICROOPTO family offers the customer high-quality
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationA rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection
65 Power relays 20-30 65 20 Power relays 1 NO + 1 NC (SPST-NO + SPST-NC) 65.31 Flange mount Faston 250 connections 65.61 PCB mount C coils & DC coils Cadmium Free option available 65.31 65.61 20 rated
More informationSafety Relay Unit. OFF-delay time
Safety Relay Unit The Series Offers a Complete Line-up of Compact Units. Four kinds of -mm wide Units are available: A -pole model, a -pole model, and models with poles and OFF-delay poles, as well as
More informationStandard voltages. Alternating current (V). Direct current (V) D F H J N Y Voltage For contactors type CL...
Series CL Three and four pole contactors 9 to 05 (C3) 25 to 40 (C) Contactors lternating current up to 690V Direct current up to 440V Terminal numbering in accordance with EN 50005 and EN 5002 Fixing by
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
41 Low profile PCB relays 8-12 - 16 41 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 (3.5 mm pin pitch) 41.52-2 Pole 8 (5 mm pin pitch) 41.61-1 Pole 16 (5 mm pin pitch) PCB mount - direct or
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationType Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1
Slim Relays with Forcibly Guided Contacts Conforming to EN Standards EN50205 Class A, approved by VDE. Ideal for use in safety circuits in production machinery. Four-pole and six-pole Relays are available.
More informationSolid-State Soft Starters
Selection and ordering data Rated operational voltage U e V Soft starters for three-phase asynchronous motors 3RW30 25-1B14 3RW30 35-1B14 t ambient temperature 40 C Size Order No. Price Weight Pack. Rated
More informationPTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device
MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationBreakcontact,Front. Articleno Deliveryprogramme. Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories
Breakcontact,Front Partno. M22-K01 Articleno. 216378 Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA, IEC Construction size NZM1/2/3/4
More informationBulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide
Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................
More informationSwitching Devices Contactors and Contactor Assemblies for Switching Motors
Switching Devices Contactors and Contactor Assemblies for Switching Motors groups 41B, 41H / Introduction Power contactors for switching motors /5 General data /11 SIRIUS RT10 contactors, -pole,... 50
More informationXT IEC Power Control Miniature Controls
Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)
More informationNS..S contactor relays - with spring terminals AC operated
NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed
More information2 or 4 pole changeover contact Plug-in/Faston 187
56 Miniature power relays 56 Plug-in - Power relay, & 4 pole Flange mount option - (Faston 87, 4.8 x 0.5 mm termination) C coils & DC coils Lockable test button and mechanical flag indicator Cadmium Free
More informationNo-wear isolation of potentials in terminal block design
TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly
More information30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view
66 Series - Power relays 30 A Features 66.22 66.82 2 Pole Changeover (DPDT) 30 A Power relay 66.22 PCB connections & mount 66.82 Faston 250 connections - Flange mount Reinforced insulation between coil
More informationSupplemental Motor Protection Devices Table of Contents
Supplemental Motor Protection Devices Table of Contents Supplemental Motor Protection Devices Bulletin 0S/S//... Page - Bulletin 0 Arcing Ground Fault Detection System: Adjustable Trip from A... Page -
More informationMini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU
/0 Mini contactors B and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU Contents Mini Contactors B, BC, B 7, BC 7 Ordering Details... /2 Compact Reversing
More informationControl relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750
Characteristics Contact characteristics of mini-control relays and instantaneous contact blocks Number of contacts On CAp-K 4 On L-K 2 or 4 for C-K and CA3-K: 2 for CA4-K Rated operational voltage (Ue)
More informationElectronic timer CT-SDE
CDC 51 059 F000 1 Characteristics " 1 single time range from 0. to 0 s " versions with different supply voltage ranges are available: 4 AC/DC and 110-10 AC and 80-415 AC " Single-function timer with star-delta
More informationType: DILM40(RDC24) Article No.:
Type: DILM40(RDC24) Article No.: 277780 Ordering information Rated operational current AC 3 400 V I e A 40 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationPKZ 2 Manual Motor Protectors Technical Data
08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3
More information38 Series - Relay interface modules A. Features /
Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions
More informationIGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards
APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2
More information190S A N D 2 C A16 C TE
Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations
More informationJ7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947
Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit
More informationType Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
More information48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12
48 Relay interface modules 8 A 48 2 CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 2 CO 8 A s Relay with forcibly guided contacts according to EN 50205 Type 35 mm rail (EN
More informationModular equipment. Presentation, standards. Standard contactors TeSys GC
Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on
More informationComponents for safety applications
Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages
More informationNZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data
Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH 4-...-C 1) NZM6B.../ZM6A...- Frame size A 80 125 125 IEC 60 947-2 Electrical Ratings Rated impulse withstand voltage U imp V 8000 8000
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16 A (5 mm pin pitch) PCB mount - direct
More informationTable of contents. Selection table 150. General purpose relays G2RS 152 MY 153 LY 155 MK-I-S 156 G7J 157
148 Table of contents Selection table 150 General purpose relays G2RS 152 MY 153 LY 155 MK-I-S 156 G7J 157 149 Selection table Category Control panel relay DC voltage AC voltage Features Selection criteria
More informationSeries P. Applications
Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any
More informationSmall but rugged DRAFT
Series C8 and CT8 Starters n ingenious miniature contactor and starter system Sprecher + Schuh s New C8 Series of miniature contactors and starters provide an extremely compact and reliable method of controlling
More information62.22 Copper side view
62 Power relays 16 62 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced insulation between coil and contacts according to EN 60335-1,
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationThree-phase monitoring relay
1SR 550 870 F9400 Features Monitoring of three-phase mains for phase failure, over- and undervoltage Device with possibility of neutral monitoring available Device with suitability for monitoring single-phase
More information22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection
Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety
More information48 Series - Relay interface modules A. Features
Series - Relay interface modules 8-0 - 6 A Features & Pole relay interface modules, 5.8 mm wide. Ideal interface for PLC and electronic systems.3 - Pole 0 A.5 - Pole 8 A.6 - Pole 6 A coils or sensitive
More informationAuxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)
Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,
More informationIMPULSE SWITCH, REMOTE SWITCH
W REMOTE SWITCH STELLA W SCHRACK INFO Low switching noise Energy saving function 0.5 30 minutes High switching capacity, 80 A start-up peak LED display LQ540000 W APPLICATIONS 220 The ideal solution for
More informationDPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR
General-purpose Relay MY New model Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Many variations
More informationElectronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More information2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1
Features 7S.12...5110 7S.14...0220/0310 7S.16..0420 Relay module with forcibly guided contacts 7S.12 with 2 pole (1NO + 1 NC) 7S.14 with 4 pole (2 NO + 2 NC and 3 NO + 1 NC) 7S.16 with 6 pole (4 NO + 2
More informationAF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF
ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC
More information20 Series Power Relays
Power Relays 0 Technical Data... Specification... Model Number Structure - Power Relays...3 Model Number Selection... - 7 Accessories... Mounting Clips... Electrical Characteristics... Dimensions... Instructions...3
More informationRelay interface modules A
4C SЕRIES Relay interface modules 8-10 - 16 A Escalators Road / tunnel lighting Hoists and cranes Carousel warehouses Control panels Panels for electrical distribution FINDER reserves the right to alter
More informationThree-phase monitoring relay
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More information190S A N D 2 C A16 C TE
Bulletin / Eco and Compact Combination Starters Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for
More informationBlock Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4
/0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors
More information3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays
.4 D7 Series Relay Contents Description D1RR/D1RF Series......................... D2RR/D2RF Series......................... DRR/DRF Series......................... D4 Series................................
More informationSelection tables Command devices E 250 latching relays
E 50 latching relays E 50 E 50 Latching relays Allow switching of the contacts in response to each pulse sent to the coil via the normally open pushbuttons. Their high performance in the single or multi-point
More information60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay
Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket
More informationSafety Relay H-462. Dimensions LxWxH(in mm) Size 1: 57,8 x20,5 x48,6 Size 2: 67,4 x20,5 x48,6
General 4or 6 contacts Forced guided contact set According to EN 50205, application type A Ambient temperature 25 +80 C Soldering heat resistance 260 C/5s RoHS compliance Signal relay according to UIC
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More information62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay
62 Series - Power relays 16 62 SERIES Features 62.22 / 62.23 62.22-0300 / 62.23-0300 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced
More informationA rated contacts PCB mount - bifurcated terminals. Copper side view
66 Power relays 30 66 2 Pole Changeover (DPDT) 30 Power relay 66.22 PCB connections & mount 66.82 Faston 250 connections - Flange mount Reinforced insulation between coil and contacts according to EN 60335-1;
More information