Bulletin 800MR/800MB Push Buttons

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Bulletin 800MR/800MB Push Buttons"

Transcription

1 ulletin 800MR/800M Push uttons ulletin 800MR uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight Round operators ul. 800MR ulletin 800M uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight Square backlit operators UL Listed File: E14840, E10314 Guide: NKCR, NIV CSA Certified: LR1234, LR11924 IEC Compliance, IEC 529 ul. 800M ul. 800MR - Momentary Contact Push uttons uild a Catalog Number Momentary Contact Push utton Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Flush Head Unit 800MR-A1 Extended Head Unit 800MR-2A Mushroom Head Unit 800MR-D2

2 Contact Type utton Color Flush Head Extended Head Mushroom Head 1 N.. Green 800MR-A1D1 800MR-1D1 800MR-D1D1 lack 800MR-A2D1 800MR-2D1 800MR-D2D1 Red 800MR-A6D1 800MR-6D1 800MR-D6D1 1 Green 800MR-A1D2 800MR-1D2 800MR-D1D2 lack 800MR-A2D2 800MR-2D2 800MR-D2D2 Red 800MR-A6D2 800MR-6D2 800MR-D6D2 1 N Green 800MR-A1A 800MR-1A 800MR-D1A lack 800MR-A2A 800MR-2A 800MR-D2A Red 800MR-A6A 800MR-6A 800MR-D6A 2 N Green 800MR-A1 800MR-1 800MR-D1 lack 800MR-A2 800MR-2 800MR-D2 Red 800MR-A6 800MR-6 800MR-D6 800MR A 1 A a b c d a b c d perator Type utton Color Standard Contact Cartridges Contact lock Termination Type Code Description Code Description Code Description Code Description A Flush head 1 Green lank No contacts lank Stab terminals Extended head 2 lack A 1 N K Large screw D Mushroom head 3 range A2 2 N.. 4 Grey A3 1 N..E.M. - 1 L.. 5 White A4 2 6 Red A7 1 L lue 2 N Yellow D1 1 N.. D2 1 Guards must be ordered separately. Logic Reed and small screw blocks can be ordered separately. Momentary Contact Push utton Units, Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Flush Head Unit 800MR-QA24GA Extended Head Unit 800MR-P16RA Mushroom Head Unit 800MR-QM24RA

3 Contact Type Power Module Type Supply Voltage Lamp Type Lens Color Flush Head Extended Head Mushroom Head 1 N Full Voltage 24V AC/DC Incandescent Red 800MR-QA24RA 800MR-Q24RA 800MR-QM24RA Green 800MR-QA24GA 800MR-Q24GA 800MR-QM24GA Amber 800MR-QA24AA 800MR-Q24AA 800MR-QM24AA Transformer 120V AC Incandescent Red 800MR-PA16RA 800MR-P16RA 800MR-PM16RA Green 800MR-PA16GA 800MR-P16GA 800MR-PM16GA Amber 800MR-PA16AA 800MR-P16AA 800MR-PM16AA Full Voltage 12V AC/DC LED Red 800MR-QAL12RA 800MR-QL12RA 800MR-QML12RA Green 800MR-QAL12GA 800MR-QL12GA 800MR-QML12GA Amber 800MR-QAL12AA 800MR-QL12AA 800MR-QML12AA 24V AC/DC LED Red 800MR-QAL24RA 800MR-QL24RA 800MR-QML24RA Green 800MR-QAL24GA 800MR-QL24GA 800MR-QML24GA Amber 800MR-QAL24AA 800MR-QL24AA 800MR-QML24AA Transformer 120V AC LED Red 800MR-PAL16RA 800MR-PL16RA 800MR-PML16RA Green 800MR-PAL16GA 800MR-PL16GA 800MR-PML16GA Amber 800MR-PAL16AA 800MR-PL16AA 800MR-PML16AA 800MR PA L 24 R a b c d e f a b c d e f perator Illumination ptions Input Voltage Lens Color Standard Contact Cartridges Transformer Full Voltage Contact lock Termination Type Code Description Code Description Code Description Code Color Code Description Code Description PA Flush lank Standard illumination as determined by power module type 12 12V AC/DC A Amber lank No contacts lank Stab terminals P Extended L LED 24 24V AC/DC lue A 1 N K Large screw PM Mushroom V AC C Clear A2 2 N.. Full Voltage Transformer G Green A3 1 N..E.M. - 1 L.. Code Description Code Description R Red A4 2 QA Flush V AC 50/60 Hz W White A7 1 L Q Extended V AC 50/60 Hz No lens with contact blocks 2 N.. 2 QM Mushroom lank No lens without contact blocks D1 D2 1 N.. 1 LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. nly available with LED Illumination option. nly available with full voltage power module option and standard stab terminations. Guards must be ordered separately. Logic Reed and small screw blocks must be ordered separately. ul. 800MR Push Pull uild a Catalog Number 2-Position Push-Pull and Push-Pull/Twist Release Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.

4 2-Position Push-Pull 800MR-F6A 2-Position Push-Pull/Twist 800MR-FT6A4 Contact Type perator Position utton Color Push-Pull Push-Pull/ Twist Release Maintained Maintained ut In No Contacts Red 800MR-F6 800MR-FT6 1 N.. Red 800MR-F6D1 800MR-FT6D1 1 Red 800MR-F6D2 800MR-FT6D2 1 N Red 800MR-F6A 800MR-FT6A 1-1 Red 800MR-F6A4 800MR-FT6A4 Note: = Closed/ = pen 3-Position Push-Pull Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. 3-Position Push-Pull 800MR-FN6A7 Contact Type perator Position utton Color Push-Pull Momentary Maintained Momentary ut Center In No Contacts Red 800MR-FN6 1 N Red 800MR-FN6A 1-1 L.. Red 800MR-FN6A7 1-1 L L.. Red 800MR-FN66 Note: = Closed/ = pen 800MR F T 6 A a b c d e f (2-Position)

5 800MR F N 6 A a b 1 c d e f (3-Position) a b b 1 c perator Type perator Function perator Function perator 2-Position 3 Position Code Description Code Description Code perator Position Code Color F Push-pull unit lank Maintained push pull lank Non-illuminated T Twist-release ut Center In N Momentary Maintained Momentary d e f utton Color Contact Cartridges Contact lock Termination Type Code Description Code Description Code Color lank No contacts lank Stab terminals 1 Green A 1 N K Large screw 2 lack A2 2 N.. 3 range A4 2 4 Grey A7 1 L White 2 N Red D1 1 N.. 7 lue D2 1 9 Yellow Note: See Table 1 for Target description. lank No cap Table 1. Target Selection Code 2-Position Contact Description 3-Position Code ut In ut Center In lank No contacts lank D1 N.. D2 A N.. - A A2 N.. - N.. A2 A4 - A4 - L.. A7 N.. - N.. - Note: = Closed/ = pen Not available in twist release. Logic Reed and small screw blocks must be ordered separately. 2-Position Push-Pull and Push-Pull/Twist Release Units, Illuminated

6 Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Illuminated 2-Position Push-Pull 800MR-FQ24RA Illuminated 2-Position Push-Pull/Twist 800MR-FTP16RA Lamp Type Power Module Type Supply Voltage Lens Color perator Position Push-Pull Push-Pull/ Twist Release Maintained Maintained Contacts ut In Incandescent Full Voltage 12V AC/DC Red N MR-FQ12RA 800MR-FTQ12RA 24V AC/DC Red 800MR-FQ24RA 800MR-FTQ24RA Transformer 120V AC Red N MR-FP16RA 800MR-FTP16RA 240V AC Red 800MR-FP26RA 800MR-FTP26RA LED Full Voltage 12V AC/DC Red N MR-FQL12RA 800MR-FTQL12RA 24V AC/DC Red 800MR-FQL24RA 800MR-FTQL24RA Transformer 120V AC Red N MR-FPL16RA 800MR-FTPL16RA 240V AC Red 800MR-FPL26RA 800MR-FTPL26RA Note: = Closed/ = pen Transformers operate at 50/60 Hz. 3-Position Push-Pull Units, Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Illuminated 3-Position Push-Pull 800MR-FNQ24RA7

7 Lamp Type Power Module Type Supply Voltage Lens Color perator Position Push-Pull Momentary Maintained Momentary Contacts ut Center In Incandescent Full Voltage 12V AC/DC Red L MR-FNQ12RA7 24V AC/DC Red 800MR-FNQ24RA7 Transformer 120V AC Red L MR-FNP16RA7 240V AC Red 800MR-FNP26RA7 LED Full Voltage 12V AC/DC Red L MR-FNQL12RA7 24V AC/DC Red 800MR-FNQL24RA7 Transformer 120V AC Red L MR-FNPL16RA7 240V AC Red 800MR-FNPL26RA7 Note: = Closed/ = pen Transformers operate at 50/60 Hz. 800MR F T P 16 R A a b c d e f g h (2-Position) 800MR F N P 16 R A a b 1 c d e f g h (3-Position) a b b 1 c d perator Type perator Function perator Function perator Type Illumination ptions 2-Position 3-Position Code Description Code Description Code perator Position Code Description Code Description F Push-pull unit lank Maintained P Transformer lank Incandescent lamp T Twist-release ut Ctr. In Q Full voltage L LED N Mom Main Mom Mom-Momentary Main-Maintained e f g h Voltage utton Color Contact Cartridges Contact lock Termination Type Full Voltage Code Description Code Color Code Description Code Description 12 12V AC/DC A Amber lank No contacts lank Stab terminals 24 24V AC/DC lue A 1 N K Large screw V AC C Clear A2 2 N.. Transformer G Green A4 2 Code Description R Red A7 1.L V AC 50/60 Hz W White 2 N V AC 50/60 Hz No cap D1 1 N.. D2 1 Note: See Table 1 for Target description.

8 Table 2. Target Selection Code 2-Position Contact Description 3-Position Code ut In ut Center In lank No contacts lank D1 N.. D2 A N.. - A A2 N.. - N.. A2 A4 - A4 - L.. A7 N.. - N.. - Note: = Closed/ = pen Not available in twist release. LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. nly available with LED Illumination option. nly available with full voltage power module option and standard stab terminations. Logic Reed and small screw blocks must be ordered separately. ul. 800MR - Selector Switches uild a Catalog Number 2-Position Selector Switch Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-HH2LA Knob Lever perator 800MR-HK2LA Contact Type Knob Color Contact perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever lack A M M 800MR-HH2LA 800MR-HK2LA S M 800MR-HH4LA 800MR-HK4LA 1 N M S 800MR-HH5LA 800MR-HK5LA lack A M M 800MR-HH2 800MR-HK2 S M 800MR-HH4 800MR-HK4 Right A 2 N M S 800MR-HH5 800MR-HK5 Note: = Closed/ = pen 2-Position Cylinder Lock perator 800MR-H31

9 Contact Type Contact perator Position perator Type M = Maintained S = Spring Return Cylinder Lock Lock in Lock in Right Lock in oth A M M 800MR-H31LA 800MR-H32LA 800MR-H33LA S M 800MR-H42LA 1 N M S 800MR-H48LA A M M 800MR-H31 800MR-H32 800MR-H33 S M 800MR-H42 Right A 2 N M S 800MR-H48 Note: = Closed/ = pen Target tables are reversed from those shown. Key removable in locked position only. 800MR H H 2 L A a b c d e e 1 f (Selector Switch) 800MR H 31 L A a b c 1 c 2 d e e 1 f (Cylinder Lock) a b c c 1 c 2 perator Positions perator Color and Type perator Function perator Function/Locking Position Key Codes Standard Knob Standard Knob Maintained Code Key No. Master Key Code Description Code Description Code Description Code Description lank T100 (standard) 1T H 2-position selector switch No knob 2 Maintained 31 Lock in left 02 T101 1T H 2-position cylinder lock H lack 4 Spring return from left Knob Lever 5 Spring return from right 32 Lock in right 03 T102 1T 33 Lock in both 04 T106 1T Code Description Spring Return From 05 T107 1T No knob lever Code Description 07 T109 2T K lack 42 Lock in right 08 T134 2T Cylinder Lock Spring Return From Right 09 T135 2T Code Description Code Description 10 T136 2T lank Key 48 Lock in left 14 T147 2T

10 d e e 1 f Cam Type Contact Cartridge Position Contact Cartridges Contact lock Termination Type Code Description Code Description Code Description Code Description cam lank oth left and right lank No contacts lank Stab terminals L A 1 N K Large screw A2 2 N.. A4 2 2 N D1 1 N.. D2 1 P1 3 N.. P2 3 P3 2 N P4 2-1 N.. P5 4 N.. P6 4 P7 3 N P8 1 N Note:See Table 1 for Target arrangements Table 1. Selector Switch Cam Targets Cam Description (2-Position) Target perator Function Maintained and Spring Returned From Right Spring Returned From N.. N.. Note: = Closed/ = pen Key removable in locked position only. If no optional key code is specified, the standard key (T100) will be supplied. Red, green, blue, yellow, orange, grey, and white non illuminated selector switch knobs and lever knobs must be ordered separately. Logic Reed and small screw contact blocks must be ordered separately. Contact cartridge position code (Table e) must be L. Contact cartridge position code (Table e) must be Position Selector Switch Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-JH2 Knob Lever perator 800MR-JK2

11 Contact Type Color Contact perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever lack A M M M 800MR-JH2LA 800MR-JH2LA S M M 800MR-JH4LA 800MR-JK4LA M M S 800MR-JH5LA 800MR-JK5LA 1 N S M S 800MR-JH9LA 800MR-JK9LA lack A M M M 800MR-JH2 800MR-JK2 S M M 800MR-JH4 800MR-JK4 Right A M M S 800MR-JH5 800MR-JK5 2 N S M S 800MR-JH9 800MR-JK9 Note: = Closed/ = pen Cylinder Lock perator 800MR-J44 Contact Type Contact perator Position perator Type M = Maintained S = Spring Return Cylinder Lock Lock in All Lock in Center Lock in Right A M M M 800MR-J44LA 800MR-J42LA 800MR-J43LA S M M 800MR-J50LA 800MR-J52LA M M S 800MR-J38LA 1 N S M S 800MR-J631LA A M M M 800MR-J44 800MR-J42 800MR-J43 S M M 800MR-J50 800MR-J52 Right A M M S 800MR-J38 2 N S M S 800MR-J631 Note: = Closed/ = pen Key removable in locked position only. 800MR J H 2 L A a b c d e e 1 f (Selector Switch) 800MR J 41 L A a b c 1 c 2 d e e 1 f (Cylinder Lock)

12 a b c c 1 perator Positions perator Color and Type perator Function perator Function/Locking Position Standard Knob Description Knob Lever Maintained Code Description Code Code Code Description Code Description J 3-position selector switch No knob 2 Maintained 41 Lock in left J 3-position cylinder lock H lack K 4 Spring return from left 42 Lock in center lank Key lank 5 Spring return from right 43 Lock in right 9 Spring return from both 44 Lock in all positions 45 Lock in left and center 46 Lock in right and left 47 Lock in right and center Spring Return From Code Description 50 Lock in center 52 Lock in right 51 Lock in right and center Spring Return From Right Code Description 69 Lock in left 38 Lock in center 73 Lock in left and center Spring Return From and Right Code Description 631 Lock in center c 2 d e e 1 f Key Codes Cam Type Contact Cartridge Position Contact Cartridges Contact lock Termination Type 1T Master Series Standard Description Code Key No. Code Description Code Description Code side Right side Code Description lank T100 (standard) cam lank oth left and right lank No contacts lank Stab terminals 02 T101 K K cam L A 1 N..-1 K Large screw 03 T102 P P cam R Right A3 1 N..E.M.-1 L.. 04 T106 U U cam 1 N T107 P1 2 N.. 1 N.. 2T Master Series P2 2 1 Code Key No. P3 2 N T109 P4 2 1 N.. 08 T134 P5 2 N.. 2 N.. 09 T135 P T136 P7 2 N.. 1 N T147 P8 2 1 N P9 1 N.. 1 T1 1 N Note:See Table 1 for cam and contact block selection. Key removable in locked position only. If no optional key code is specified, the standard key (T100) will be supplied. Red, green, blue, yellow, orange, grey, and white non illuminated selector switch knobs and lever knobs must be ordered separately. Logic Reed and small screw contact blocks must be ordered separately. Contact cartridge position code (Table e) must be L or R. Contact cartridge position code (Table e) must be --. Table 1. Selector Switch Cam Targets

13 Note: = Closed/ = pen Cam Description Target K P U Right Right Right Right N.. N.. N.. N.. N.. N.. N.. N.. N..E.M. N..E.M. L.. N..E.M. L.. L.. L.. L.. L.. 4-Position Selector Switch Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-NH2Q Knob Lever perator 800MR-NK2Q Contact Type Color Contact perator Position perator Type Standard Knob Knob Lever lack A Maintained in All Positions 800MR-NH2Q 800MR-NK2Q 2 N Right A Note: = Closed/ = pen Cylinder Lock perator 800MR-N31Q Contact Type Contact perator Position perator Type Cylinder Lock Lock In All Lock In Position 1 Lock In Position 2 A Maintained in All Positions 800MR-N61Q 800MR-N31Q 800MR-N32Q 2 N Right A Note: = Closed/ = pen Key removable in locked position only.

14 800MR N H 2 Q a b c d e f (Selector Switch) 800MR N 31 Q a b c 1 c 2 d e f (Cylinder Lock) a b c c 1 perator Positions perator Color and Type perator Function perator Function/Locking Position Standard Knob Description Knob Lever Standard Key Code Description Code Code Code Description Code Description N 4-position selector No knob 2 Maintained 31 Lock in position 1 N 4-position cylinder lock H lack K 32 Lock in position 2 lank Key lank 33 Lock in position 3 34 Lock in position 4 41 Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in position Lock in all positions c 2 d e f Key Codes Cam Type and Target Table Contact Cartridges Contact lock Termination Type Code Key No. Master Key Q Standard lock/stab Terminations Code Description lank T100 (standard) 1T Target Contact Type (Rear View) Code Description lank Stab terminals 02 T101 1T Right lank No contacts K Large screw 03 T102 1T 1 N.. 2 N T106 1T 1 05 T107 1T 1 N.. 07 T109 2T 1 08 T134 2T Note: = Closed/ = pen 09 T135 2T 10 T136 2T 14 T147 2T Red, green, blue, yellow, orange, grey, and white non illuminated selector switch knobs and knob levers must be ordered separately. Key removable in locked position only. perators are maintained in all positions. If no optional key code is specified, the standard key (T100) will be supplied. Logic Reed and small screw contact blocks must be ordered separately. 2-Position Knob/Lever Type Selector Switch Units, Illuminated

15 Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-24HA2RA Knob Lever perator 800MR-24HL2RA Contact Type Type Volts Lamp Knob Color perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever Full Voltage 24V AC/DC Incandescent Red Transformer 120V AC Red Full Voltage 24V AC/DC LED Red Transformer 120V AC Red M M 800MR-24HA2RA 800MR-24HL2RA S M 800MR-24HA4RA 800MR-24HL4RA M S 800MR-24HA5RA 800MR-24HL5RA M M 800MR-16HA2RA 800MR-16HL2RA S M 800MR-16HA4RA 800MR-16HL4RA M S 800MR-16HA5RA 800MR-16HL5RA M M 800MR-24HAL2RA 800MR-24HLL2RA S M 800MR-24HAL5RA 800MR-24HLL5RA M M 800MR-16HAL2RA 800MR-16HLL2RA S M 800MR-16HAL4RA 800MR-16HLL4RA 1 N M S 800MR-16HAL5RA 800MR-16HLL5RA Note: = Closed/ = pen Transformers operate at 50/60 Hz. Target tables are reversed from those shown. 3-Position Knob/Lever Type Selector Switch Units, Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-24JA2RA Knob Lever perator 800MR-24JL2RA

16 Contact Type Type Volts Lamp Knob Color perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever Full Voltage 24V AC/DC Incandescent Red M M M 800MR-24JA2RA 800MR-24JL2RA S M M 800MR-24JA4RA 800MR-24JL4RA S M S 800MR-24JA9RA 800MR-24JL9RA Transformer 120V AC Red M M M 800MR-16JA2RA 800MR-16JL2RA S M M 800MR-16JA4RA 800MR-16JL4RA S M S 800MR-16JA9RA 800MR-16JL9RA Full Voltage 24V AC/DC LED Red M M M 800MR-24JAL2RA 800MR-24JLL2RA S M M 800MR-24JAL4RA 800MR-24JLL4RA S M S 800MR-24JAL9RA 800MR-24JLL9RA Transformer 120V AC Red M M M 800MR-16JAL2RA 800MR-16JLL2RA S M M 800MR-16JAL4RA 800MR-16JLL4RA 1 N S M S 800MR-16JAL9RA 800MR-16JLL9RA Note: = Closed/ = pen Transformers operate at 50/60 Hz. 800MR 24 H A L 2 R A a b c d e f g 1 g 2 h (2-Position) 800MR 24 J A L 2 R A a b c d e f 1 g 1 g 2 h (3-Position) a b c Input Voltage perator Positions perator Color and Type Full Voltage Standard Knob Description Knob Lever Code Description Code Description Code Code 12 12V AC/DC H 2-position No knob 24 24V AC/DC J 3-position A Red L V AC Green M Transformer D Amber P Code Description Y Clear Z V AC 50/60 Hz V AC 50/60 Hz d e f f 1 Illumination ptions perator Function Cam Type (2-Position) Cam Type (3-Position) Code Description Code Description Code Description Code Description lank Incandescent 2 Maintained cam cam L LED 4 Spring return from left Note:For Target arrangements see Table 1. K K cam 5 Spring return from right P P cam 9 Spring return from both U U cam Note:For Target arrangements see Table 2.

17 g 1 g 2 h Contact Cartridge Position Contact Cartridges Contact lock Termination Type Code Description Description lank oth right and left Code side Right side Code Description R Right lank No contacts lank Stab terminals A 1 N..-1 K Large screw A2 2 N.. A3 1 N..E.M.- 1 L.. A4 2 1 N N..-1 D1 1 N.. D2 1 P1 2 N.. 1 N.. P2 2 1 P3 2 N.. 1 P4 2 1 N.. P5 2 N.. 2 N.. P6 2 2 P7 2 N.. 1 N..-1 P8 2 1 N..-1 P9 1 N.. 1 N.C T1 1 N Note: See Table 1 for 2-position contact block selection. See Table 2 for 3-position contact block selection. nly available with LED Illumination option. LEDs only available in red, green, amber and white. Knob color must match LED color, except clear knob supplied with white LED. nly available with full voltage power module and standard stab terminations. Logic Reed and small screw contact blocks must be ordered separately. Contact cartridge position code (Table g1) must be R. Contact cartridge position code (Table g1) must be --. nly available for 2 position selector switches. Table 1. Selector Switch Cam Targets Cam Description (2-Position) Target perator Function Maintained and Spring Return From Right Spring Return From N.. N.. Note: = Closed/ = pen Table 2. Selector Switch Cam Targets Cam Description (3-Position) Target K P U Right Right Right Right N.. N.. N.. N.. N.. N.. N.. N.. N..E.M. N..E.M. L.. N..E.M. L.. L.. L.. L.. L.. Note: = Closed/ = pen 4-Position Knob/Lever Type Selector Switch Units, Illuminated Contact Terminations

18 perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-24NA2Q Knob Lever perator 800MR-24NL2Q Contact Type Type Volts Lamp Color perator Position perator Type Standard Knob Knob Lever Full Voltage 24V AC/DC Incandescent Red Maintained in All Positions 800MR-24NA2Q 800MR-24NL2Q 24V AC/DC LED Red 800MR-24NAL2Q 800MR-24NLL2Q 2 N V AC LED Red 800MR-10NAL2Q 800MR-10NLL2Q Note: = Closed/ = pen 800MR 24 N A L 2 Q a b c d e f g h (4-Position) a b c d Input Voltage perator Positions perator Color and Type Illumination ptions Full Voltage Standard Knob Description Knob Lever Code Description Code Description Code Code Code Description 12 12V AC/DC N 4 position No knob lank Incandescent 24 24V AC/DC A Red L L LED V AC Green M D Amber P Y Clear Z e f g h perator Function Cam Type and Target Table Contact Cartridges Contact lock Termination Type Q Code Standard knob function Target Contact Type (Rear View) Standard lock Code Description Code Description 2 Maintained Right 2 N lank Stab terminals 1 N N.. 1 Note: = Closed/ = pen Note: = Closed/ = pen

19 nly available with LED Illumination option. perator is maintained in all positions. LEDs only available in red, green, amber and white. Knob color must match LED color, except clear knob supplied with white LED. Logic Reed contact blocks must be ordered separately. ul. 800MR - Potentiometers, Pilot Lights, and Wobble Sticks uild a Catalog Number Potentiometer perator nly This operator is suitable for mounting potentiometers or other small single turn rotary operated devices having 3/8 in. diameter bushings (1/4 3/8 in. long) and 1/4 in. diameter shaft (3/4 1 1/2 in. long), plus providing 600V electrical clearances to panel. Includes operator, instruction sheet, and graduated marking ring. This operator does not have a resistive potentiometer element. Potentiometer Unit 800MR-N37 Type Potentiometer perator nly (without Resistive Element) 800MR-N37 Pilot Light Units Contact Terminations perators come standard with stab terminations. To order large screw contact terminations for pilot lights add letter K to the end of the cat. no. For push-to-test pilot lights add the letter K. Pilot Light 800MR-Q24R Push-to-Test Pilot Light 800MR-QT24R

20 Lamp Type Volts Color Pilot Light Push-to-Test Dual Input Incandescent Full Voltage 12V AC/DC Red 800MR-Q12R 800MR-QT12R Green 800MR-Q12G 800MR-QT12G Amber 800MR-Q12A 800MR-QT12A 24V AC/DC Red 800MR-Q24R 800MR-QT24R Green 800MR-Q24G 800MR-QT24G Amber 800MR-Q24A 800MR-QT24A Transformer 120V AC 50/60 Hz Red 800MR-P16R 800MR-PT16R 800MR-PDT16R Green 800MR-P16G 800MR-PT16G 800MR-PDT16G Amber 800MR-P16A 800MR-PT16A 800MR-PDT16A LED Full Voltage 24V AC/DC Red 800MR-QL24R 800MR-QTL24R Green 800MR-QL24G 800MR-QTL24G Amber 800MR-QL24A 800MR-QTL24A 120V AC Red 800MR-QL10R 800MR-QTL10R Green 800MR-QL10G 800MR-QTL10G Amber 800MR-QL10A 800MR-QTL10A Transformer 120V AC 50/60 Hz Red 800MR-PL16R 800MR-PTL16R Green 800MR-PL16G 800MR-PTL16G Amber 800MR-PL16A 800MR-PTL16A Dual input transformer is transformer relay type. Comes standard with screw terminations. 800MR P L 24 R a b c d e a b c perator Illumination ptions Input Voltage Transformer Full Voltage Code Description Code Description Code Description P Pilot light lank Incandescent 12 12V AC/DC PDT Pilot light dual input transformer L LED 24 24V AC/DC PT Pilot light push to test V AC Full Voltage Transformer Code Description Code Description Q Pilot light V AC 50/60 Hz QT Pilot light push to test V AC 50/60 Hz d e Lens Color Contact lock Termination Type Pilot Lights Code Color Code Description lank No lens lank Stab terminals A Amber K Large screw lue Note:If large screw terminations are desired with a dual input transformer, ( 800MR PDT ), configurator space e must be left blank. C G R W Clear Green Red White

21 LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. nly available with LED illumination option. Small screw contact blocks must be ordered separately. nly available with Push to test units. Wobble Stick Units Designed for ease of operation. Wobble stick units have spring return action and may be operated from any angle. It is particularly useful with pendant stations. Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations are sold separately. Wobble Stick Unit 800MR-M1 Contact Type Contact Type 1 N MR-M1A 2 N MR-M1 800MR M1 A a b c a b c perator Type Contact Cartridges Contact lock Termination Type Code Description Code Description Code Description M1 Wobble stick lank No contacts lank Stab terminals A 1 N K Large screw 2 N Logic Reed and small screw contact blocks must be ordered separately. Specifications

22 Electrical Ratings Contact Ratings Dielectric Strength Electrical Design Life Cycles Refer to the Contact Ratings tables below. 1600V for one minute 1300V for one minute (Logic Reed) at maximum rated load at maximum rated load (Logic Reed) Mechanical Ratings Vibration Shock Degree of Protection Hz 1.52 mm displacement (peak to peak) Max./10 G Max. (except Logic Reed) 1/2 cycle sine wave for 11 milliseconds ³ 25 G (contact fragility) and no damage at 100 G Type 13; IEC I44 IP65 iltight Mechanical Design Life Cycles Push uttons Potentiometers All other devices Contact peration minimum minimum minimum Contact blocks with ifurcated spanner:slow make and break, simple break. Logic Reed Contact locks:snap-action Typical perating Forces perators without contact blocks 2.45 lb (10.8 N) Push-Pull Units 8 lb (35.3 N) push to in position 4 lb (17.7 N) maximum pull to out position Contact locks Standard 1.5 lb (6.7 N) Logic Reed lb (2.6 N) Environment Temperature Range perating F (0 55 C) Storage F ( C) Note:perating temperatures at +32 F (0 C) are based on the absence of freezing moisture and liquids. Humidity Panel Thickness Requirements 50% at 104 F (40 C) 1/16 1/4 in. ( mm) Performance Data See Performance Data. Standard Contact Ratings (IEC 337-1) (NEMA ICS 2-125) Maximum continuous current I th 10 A. ulletin 800M units have control circuit ratings with 800M contact blocks as follows: Maximum perational Volts Ue Utilization Category Rated perational Currents IEC NEMA Volts Ue Make reak AC 300 AC-II A VA 720 VA VA 720 VA A 10 A For applications below 24V and 24 ma, Logic Reed contacts are recommended. Logic Reed Contact Ratings Maximum: 150V AC, 0.15 A, 8 VA and 30V DC, 0.06 A, 1.8 VA. Should only be used with resistive loads. Wire Capacity Stab Termination Contact locks Accepts two x in. push-on connectors or one x in. push-on connector. Small Screw Contact locks Accepts one #14 or two #16 AWG solid or stranded wires. Large Screw Termination Contact locks Accepts two #12 AWG solid or stranded wires. Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. ul. 800MR Extension in Front of Panel

23 Round Push utton Flush, Extended and Illuminated Extended Round Push utton Illuminated Flush Round Push utton Mushroom Round Selector Switch and Potentiometer and Standard Knob Panel Wobble Stick Unit Round Selector Switch and Potentiometer and Wing Lever Round Cylinder Lock Selector Switch Round Push-Pull Twist or Pull Release Units ul. 800M Front View of Square Units CAUTIN: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction. Unit without Insert and acklit Unit Square acklit with Guarded ezel Square acklit with Unguarded ezel Dual perator Unit ul. 800M Extension in Front of Panel Square Push utton Flush and Extended Square Push utton Large Extended Square Push utton Dual perator Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Extension ehind Panel Units with Quick Connect Terminal Contact locks (Typical View) Units Having Screw Terminals with Pressure Plate Contact locks (Typical View) Units Having Large Screw Terminals with Pressure Plate Contact locks (Typical View) Panel Depth Requirements 1/16 1/4 in. ( mm)

24 Dimension A Description Push utton Pilot Light Sel. Switch Cyl. Lock Pot. Push-Pull or Twist Release Push utton Pilot Light Sel. Switch Cyl. Lock Pot. Push-Pull or Twist Release Units with Quick Connect Terminals Units Having Small Screw Terminals with Pressure Plates Non-Illuminated 2-1/4 (57.2) 2-15/32 (62.7) 3-1/2 (88.9) 2-1/32 (51.6) 2-3/4 (69.8) 2-5/16 (59) 2-17/32 (64.3) 3-9/16 (90.5) 2-1/32 (51.6) 2-13/16 (71.4) Illuminated Full Voltage 2-1/4 (57.2) 2-1/4 (57.2) 2-15/32 (62.7) 2-3/4 (69.8) 2-25/32 (70.6) 2-25/32 (70.6) 2-17/32 (64.3) 2-13/16 (71.4) Transformer 2-23/32 (69.1) 2-23/32 (69.1) 2-29/32 (73.8) 3-3/32 (78.6) 2-25/32 (70.6) 2-25/32 (70.6) 2-31/32 (75.4) 3-5/32 (80.1) Non-Illuminated Units Having Large Screw Terminals with Pressure Plates 2-45/64 (68.6) 2-59/64 (74.2) 3-15/16 (100) 3-13/64 (81.4) Illuminated Full Voltage 3-11/64 (80.6) 3-11/64 (80.6) 3-23/64 (85.3) 3-13/64 (81.4) Transformer 3-11/64 (80.6) 3-11/64 (80.6) 3-23/64 (85.3) 3-35/64 (90.1) Approximate Mounting Dimensions Caution: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1 1/2 in. (38.1 mm) minimum centers in one direction. Large screw terminal contact blocks require a minimum vertical spacing of 1 37/64 in. (40 mm); selector switches with wing lever knobs require 2 1/4 in. (57.1 mm) vertical and horizontal minimum spacing and large round legend plates require 1 1/2 in. (38.1 mm) minimum spacing. Shipping Weights in unces (kg) Type of Unit Weight Type of Unit Weight Push uttons Non-Illuminated 3-1/4 (0.09) Selector Switches Non-Illuminated 4 (0.11) Illuminated Full Voltage 3-1/2 (0.10) Illuminated Full Voltage 4 (0.11) Transformer 5 (0.14) Transformer 5-1/2 (0.16) Pilot Lights Pilot Light 2-1/4 (0.06) Push-Pull Units Non-Illuminated 4-1/2 (0.13) Push-to-Test 3 (0.09) Pilot Light 4-1/2 (0.13) Illuminated Full Voltage 4-1/2 (0.13) Push-to-Test 5 (0.14) Transformer 5-1/2 (0.16) Cylinder Lock 6 (0.17) Potentiometer Units 4 (0.11) Padlocking Cover 800MR-N6 When using a padlocking cover and depending upon the types of adjacent units involved, the minimum vertical or horizontal spacing may have to be increased for operating clearance.

25 Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Legend Plates Standard Half Round Legend Plate Standard Legend Plate Large Size Round Small/Large Legend Plate The ulletin 800MR large half round legend plates are not recommended for use with the twist release units because of the operator knob size. The legend plate is virtually unreadable. Push pull units can be mounted in a 1 1/4 in. minimum horizontal spacing when no legend plate is used. Vertical spacing is 1 1/2 in. when the ulletin 800MR large half round legend plate is used. These ulletin 800MR legend plates consist of ulletin 800T legend plates with 800MR N50 adapter rings. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

Bulletin 800MR/800MB Push Buttons

Bulletin 800MR/800MB Push Buttons ulletin 800MR/800M Push uttons ulletin 800MR uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight Round operators ul. 800MR ulletin 800M uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight

More information

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only) 1-,, 3-, 4- Toggle Switches (Bul. 800T only) 800T T2 H2 E E X X a b c d e f g Right Left Right Left Blank C T1 T2 T3 T4 a Finger-Safe Guards Description No guards Guards on terminals b Operator Type Description

More information

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35 Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

Switches & Pilot Devices

Switches & Pilot Devices ømm - HW Series Key features: ocking lever removable contact blocks Finger-safe IP0 contacts as standard, other terminal styles available Tamperproof construction All E-stops meet EN8 and are compliant

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

Separate units: Blocks

Separate units: Blocks Separate units: Blocks LED BLOCKS Technical Info (p. 103) SCREW TERMINALS Part Number 3.8 LED 19.7 20.1 X1 X2 33EARL 9.9 19.7 21.5 18.2 12/24 V White Red Green Blue Yellow 33EAWL 33EARL 33EAGL 33EABL 33EAYL

More information

1.3. Pushbuttons and Indicating Lights.

1.3. Pushbuttons and Indicating Lights. .3 Pushbuttons and Indicating Lights Pushbutton Control Stations Contents Page Features.............................. V7-T-5 Product Selection M22 Assembled Control Stations........ V7-T-6 Commercial Control

More information

General data. 13/20 Siemens IC Overview Front plate mounting

General data. 13/20 Siemens IC Overview Front plate mounting General data Overview Front plate mounting D C B E A F D NSD0_00029b B C A A B C D E F Actuator Front plate Holder Contact block Lampholder Support element For actuators see page /25 to /62. For contact

More information

TWTD Series: Heavy duty switches built to last

TWTD Series: Heavy duty switches built to last ø0mm - TWTD Series iltight TWTD Series Full Size NEMA Pushbuttons TWTD Series: Heavy duty switches built to last features include: Variety of button sizes up to 9/6" (65mm) Rugged construction includes

More information

Model Number Structure

Model Number Structure General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long

More information

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features: RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator

More information

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors All Sensors Retroreflective Polarized Retroreflective ClearSight TM Standard Diffuse Long Range Diffuse Extended

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

Major 5001 Wire Stripper

Major 5001 Wire Stripper Major 5001 Wire Stripper F e a t u r e s Stripping of 14 to 30 awg wire without blade changes Complete or partial removal of the insulation Small space required 7" x 15" 120 VAC Power Virtually maintenance

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

Operation Manual February Opticom Infrared System

Operation Manual February Opticom Infrared System Operation Manual February 2008 Opticom Infrared System M195/196, M9192, M292, M9592, M592 Emitters M511, M521, M522 Detectors M262, M562 Phase Selectors M360, M560 System Chassis M5168, M5575 Interface

More information

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers Solid-state Timer H3CR DIN 48 x 48-mm Multifunctional Timer Series Conforms to EN61812-1 and EN60664-1 (VDE0110) 4 kv/2 for Low Voltage, and EMC Directives. Approved by UL and CSA. Lloyds/NK approvals.

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS-(S) Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Polarized Transmitted Beam Fiber Optic All Sensors Retroreflective Retroreflective ClearSight TM Standard Diffuse

More information

Universal Voltage Cabled Photoelectric E3JK

Universal Voltage Cabled Photoelectric E3JK Universal Voltage Cabled Photoelectric Small Cable Sensor with Complementary Outputs Universal AC/DC supply voltage Relay or NPN/PNP transistor output, light-on or dark-on operation Polarized retroreflective

More information

Switches & Pilot Devices

Switches & Pilot Devices ømm - TW Series features: TW NEMA Switches with snap-on contacts Corrosion resistant octagonal chrome plated locking bezel Snap-on 0A contact blocks Incandescent or LED illumination Slow make, double break,

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

200 Watt Passive Shunt Module

200 Watt Passive Shunt Module Installation Instructions 200 Watt Passive Shunt Module (Catalog Number 9101-1183) Drives can require external power dissipation when large inertial loads are present. To ensure that faults due to excessive

More information

10 to 30 VDC (10% max. permissable ripple peak-to-peak)

10 to 30 VDC (10% max. permissable ripple peak-to-peak) R Background Suppression Sensor Photoelectric Sensor With Adjustable Setting Distance in Rugged Metal Housing H Stable detection regardless of material color or size of sensing object: 2% or less black/white

More information

6mm Interface Relays RV8 Series

6mm Interface Relays RV8 Series 6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of

More information

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide

More information

Laser Displacement Sensor Z4M. Ordering Information

Laser Displacement Sensor Z4M. Ordering Information Laser Displacement Sensor Compact Displacement Sensor with 1.5-micron Resolution Offers Long-distance Measurement for In-line Production Inspection High resolution with 3 user-selectable response speed

More information

General-Purpose Photoelectric Sensors with Self-Contained Amplifier

General-Purpose Photoelectric Sensors with Self-Contained Amplifier General-Purpose Photoelectric Sensors with Self-Contained Amplifier HP Series The convenience of industry standards, plus reliability. Effective light axis alignment 50% power savings Prevention of accidental

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS Timers DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to

More information

Installation Instructions

Installation Instructions VON DUPRIN Installation Instructions 98/9947WDC Concealed Vertical Rod Exit Device Wood Door Applications Devices covered by these instructions: 98/9947WDC Concealed Vertical Rod Device 98/9947WDC-F (Fire)

More information

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service Product Bulletin Code No. LIT-977319 Issued September 26, 2014 The VA-9070 Series Electric Rotary Actuators for Two-Position

More information

HMI Components. Series. Front mounting Glass mounting. Illuminated pushbutton Indicator Warning indicator Emergency call button. Public transportation

HMI Components. Series. Front mounting Glass mounting. Illuminated pushbutton Indicator Warning indicator Emergency call button. Public transportation dition 09/015 HMI Components 57 Series Characteristics The Series 57 is especially suited for: ront mounting Glass mounting It is characterised by a extra large operating area, two independently illuminated

More information

Switches & Pilot Devices

Switches & Pilot Devices ø0mm - Series Key features: Wide variety of heavy-duty oiltight cam switches Operators available up to positions Switches made with a double circuit contact block Contact blocks rated 00V, 0A Ideal for

More information

Local control stations for Zone 1 and Zone 21. Features. Description

Local control stations for Zone 1 and Zone 21. Features. Description Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning

More information

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101 CustomAS-Interface enclosures Overview There are two types of custom solutions for AS-Interface: The front panel module and the SIRIUS 3SB3 enclosed stations. NC Contacts AS-Interface enclosure Ordering

More information

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc Document No. 155-187P25 EA GDE/GLB-1 OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc Description The OpenAir direct coupled 24 Vac non-spring

More information

MONOPRICE. Modular Video Wall System with Push-to-Pop-out and Anti-Theft Features. User's Manual P/N 16102

MONOPRICE. Modular Video Wall System with Push-to-Pop-out and Anti-Theft Features. User's Manual P/N 16102 MONOPRICE Modular Video Wall System with Push-to-Pop-out and Anti-Theft Features P/N 16102 User's Manual CONTENTS SAFETY WARNINGS AND GUIDELINES... 3 INTRODUCTION... 4 FEATURES... 5 CUSTOMER SERVICE...

More information

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays .4 D7 Series Relay Contents Description D1RR/D1RF Series......................... D2RR/D2RF Series......................... DRR/DRF Series......................... D4 Series................................

More information

Amphenol. Advantage. R-Line R-146. Rectangular Attached Multi-Pin Industrial Cable Assemblies. Amphenol - Sine Systems

Amphenol. Advantage. R-Line R-146. Rectangular Attached Multi-Pin Industrial Cable Assemblies. Amphenol - Sine Systems Amphenol Rectangular Attached Multi-Pin Industrial Assemblies Advantage R-146 R-Line Amphenol - Sine Systems Advantage * vs. the R-Line Molded Advantage Series * Patents pending Low Cost UL & CSA Listed

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

Quick-Release Sliding Tail Vise 05G30.01

Quick-Release Sliding Tail Vise 05G30.01 Quick-Release Sliding Tail Vise 05G30.01 U.S. Des. Pat. No. D671,812 U.S. Pat. No. 9,050,710 Introduction The Veritas Quick-Release Sliding Tail Vise is a reworked version of the well-known tail vise that

More information

Valves with a difference. Electrical Actuators DVC INTERNATIONAL

Valves with a difference. Electrical Actuators DVC INTERNATIONAL Valves with a difference Electrical Actuators DVC INTERNATIONAL With DVC International as your business partner, you are always guaranteed a wide, well sorted product range and a unique technical know-how

More information

Installation Instructions PHOTOSWITCH R Series 9000 On/Off and Timing Photoelectric Sensors

Installation Instructions PHOTOSWITCH R Series 9000 On/Off and Timing Photoelectric Sensors Installation Instructions PHOTOSWITCH R Series 9000 On/Off and Timing Photoelectric Sensors Sensing Distance All Sensors Retroreflective Polarized Retroreflective ClearSight TM Standard Diffuse Long Range

More information

15A 3.96mm pitch Wire-to-Board Connectors for Internal Power Supply

15A 3.96mm pitch Wire-to-Board Connectors for Internal Power Supply 15A 3.96mm pitch Wire-to-Board Connectors for Internal Power Supply DF63 Series (UL, C-UL, TÜV, Listed) Features 1. Rated for up to 15A DF63 has the capacity to handle a max of 15A when using 16 AWG wire.

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 114-16016 17 APR 14 NOTE NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Unless

More information

Photoelectric Sensors E51 Limit Switch Style, Modular

Photoelectric Sensors E51 Limit Switch Style, Modular August 2007 E5 Limit Switch Style, Modular PG.05E.2.T.E E5 Modular Limit Switch Style Contents Overview...................... Model Selection, Assembled Sensors............. 2 Model Selection, Sensor Heads..................

More information

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

Line volt rail & fixtures. Low volt quick connect fixtures with transformers INSTRUCTIONS: Line Volt Flexrail2 Safety Instructions: A qualified electrician must install system only. System is intended for installation in accordance with National Electric Code, local and Federal

More information

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series Heavy Duty Door Clamping Junction Box Padlock Kit www.hammfg.com Quick Release Clamp New note style replacement hardware for use on 1418N4, 1418N4SS, 1447SN4, and 1447SN4SS Hammond enclosures. Formed heavy

More information

Waste/recycle sets. Waste/recycle sets Premium TANDEM and TANDEMBOX solutions for waste/recycle cabinets. blum.com

Waste/recycle sets. Waste/recycle sets Premium TANDEM and TANDEMBOX solutions for waste/recycle cabinets. blum.com Waste/recycle sets Waste/recycle sets Premium TANDEM and TANDEMBOX solutions for waste/recycle cabinets blum.com Waste/recycle solutions for every kitchen Blum s new TANDEM and TANDEMBOX waste/recycle

More information

Bulletin 800H mm Mounting Hole Type 4/4X/13 Corrosion-Resistant/ Watertight/Oiltight Heavy Industrial Stations and Operators TABLE OF CONTENTS

Bulletin 800H mm Mounting Hole Type 4/4X/13 Corrosion-Resistant/ Watertight/Oiltight Heavy Industrial Stations and Operators TABLE OF CONTENTS ulletin 800H Type 4/4/13, orrosion-resistant/watertight/iltight ulletin 800H 30.5 mm Mounting Hole Type 4/4/13 orrosion-resistant/ Watertight/iltight Heavy Industrial Stations and perators TLE F NTENTS

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

20 - Arc Guard Systems

20 - Arc Guard Systems Arc Guard Index Arc Guard - Arc Guard Arc Guard...1 -.14 Selection Arc Guard System, description...6...2...2 Description,...1 Description,...1 Description, with detectors...4 Description,...5 Detectors

More information

SMT TR series. Surface mount tiny washable rocker switches. Distinctive features and specifications.

SMT TR series. Surface mount tiny washable rocker switches. Distinctive features and specifications. SMT TR series Surface mount tiny washable rocker switches istinctive features and specifications Entirely designed for surface mount Tape and reel packaging Reflow solderable High temperature plastic materials

More information

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71. SERIES 61K High Resolution, 4-Pin FEATURES 25, 32, 50, 64, 100, 128 and 256 Cycles per Revolution Available Sealed Version Available Rugged Construction Cable or Pin Versions 10 Million Rotational Life

More information

IP66 IP65. Trail Wires Female Connectors. STEP 1: Measure area where system is to be installed.

IP66 IP65. Trail Wires Female Connectors. STEP 1: Measure area where system is to be installed. MODULE STRAND SYSTEM Module 5 /16" Module Strand 3 /4" Dia.130 Hole For #6 Screw 2 9 /16" 1 13 15 /16" /16" MAX 4 1 /2" MIN 2 7 /8" Module strands are manufactured with 4½" OC spacing, but can be installed

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0

More information

MY-GS CSM_MY-GS_DS_E_2_1

MY-GS CSM_MY-GS_DS_E_2_1 Miniature Power Relays CSM DS_E 1 Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays Reduces wiring work by % when combined with the PYF-PU Push-In Plus Socket

More information

THE RING RESONATOR (K-975)

THE RING RESONATOR (K-975) THE RING RESONATOR (K-975) OUTPUT BOOST The Ring Resonator An Octave Up Fuzz Modkitsdiy.com 9 VDC CENTER (-) ADAPTER TO AMP IN FROM GUITAR OUT Unplug when not in use to save battery life. Use these instructions

More information

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode General-purpose Relay CSM_G2R-_-S_(S)_DS_E 3 Slim and Space-saving Power Plug-in Relay Reduces wiring work by 60% when combined with the P2RF-@-PU Push-In Plus Socket (according to actual OMRON measurements).

More information

Self-Powered Counters H7ET

Self-Powered Counters H7ET Self-Powered Counters Subminiature Time Totalizers Require No External Power Supply Subminiature 8 x 2 mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available Printed circuit

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

E x hibitor TOKISTAR TOKISTAR LIGHTING

E x hibitor TOKISTAR TOKISTAR LIGHTING E x hibitor TOKISTAR TOKISTAR LIGHTING Exhibitor TM T okistar Exhibitor Series is a wet-location festoon lighting system used in amusement parks, shopping centers, street decorations and promenades. Exhibitor

More information

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT PDT PDT RH Series Compact

More information

E3S-CL. Distance setting photoelectric sensor in metal housing. Features

E3S-CL. Distance setting photoelectric sensor in metal housing. Features Distance setting photoelectric sensor in metal housing High water, oil and detergent resistance Minimal black/white error for highest reliability detecting different colored objects () Features Eliminates

More information

Cam Positioner H8PR. Metal body, 2 m (6.56 ft.) cable

Cam Positioner H8PR. Metal body, 2 m (6.56 ft.) cable am Positioner Economical am Positioner Does the Work of p to am Switches Easy replacement of mechanical cam es with absolute encoder input ontrol outputs can be programmed to turn N/ in increments A single

More information

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier Ultraminiature Photoelectric Sensors with Self-contained Amplifier HPJSeries HPJ Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8mm (thru scan model) 30

More information

P RODUCT C ATALOGUE 1/2002

P RODUCT C ATALOGUE 1/2002 S a f e t y R e l a y s S e r i e s U E 1 0-4 8 P RODUCT C ATALOGUE 1/2002 For technical details please unfold 2 SICK Industrial Safety Systems Germany All rights reserved 8 009 607/30-03-02 UE 10 UE 48

More information

Bulletin 1497 Global Control Transformers

Bulletin 1497 Global Control Transformers Bulletin 1497 Global Control Transformers Bulletin 1497 Global Control Circuit Transformers Bulletin 1497 Global Control Circuit Transformers are designed to reduce supply voltages to control circuits.

More information

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression WORLD-BEAM QS8AFF00 Sensors with Foreground Suppression Datasheet Compact sensors featuring extended range and foreground suppression mode Exceptional optical performance; up to 00 mm sensing range in

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Preference Collection 5580 Treatment Console INSTALLATION GUIDE Preference Collection 5580 Treatment Console INSTALLATION GUIDE 0 WARNING Failure to install the 5580 as described in this installation guide may cause the unit to collapse, resulting in serious injury

More information

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL DST-2000C Direction Sensing Tachometer INSTRUCTION MANUAL Azonix-Dynalco, 3690 N. W. 53 Street, Ft. Lauderdale, FL 33309 U.S.A.! (954) 739-4300 Fax (954) 484-3376 www.dynalco.com mailbox@dynalco.com October

More information

02/11/2015

02/11/2015 "Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue

More information

PD140FNT60QMU-02C. Through Beam. Main features. Description

PD140FNT60QMU-02C. Through Beam. Main features. Description Through eam Description The PD140 sensor consists of an emitter, which sends out invisible, infrared light, and a receiver, capable of detecting the light from the emitter. The sensor is encapsulated in

More information

RT-3 UNIT RELAY 4-POINT TERMINAL

RT-3 UNIT RELAY 4-POINT TERMINAL Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA Relay type, PhotoMOS Power (Voltage sensitive type)] RT-3 Unit relay -point Terminal [PA relay, PhotoMOS Power (Voltage sensitive

More information

TITAN-BIT KEY-CUTTING MACHINE INSTRUCTION MANUAL

TITAN-BIT KEY-CUTTING MACHINE INSTRUCTION MANUAL TITAN-BIT KEY-CUTTING MACHINE INSTRUCTION MANUAL Contents: 1 PRESENTATION AND GENERAL ASPECTS... 3 1.1 GENERAL POINTS... 3 1.2 TRANSPORT AND PACKING... 3 1.3 IDENTIFICATION LABEL... 3 2 CHARACTERISTICS

More information

FIGURE 1 - LARGE PULPER ASSEMBLY

FIGURE 1 - LARGE PULPER ASSEMBLY FIGURE - LARGE PUL ASSEMBLY FIG. & TABLE - LARGE PUL ASSEMBLY - NA UP ASSEMBLY UP SHELL, LOCAL STATUS INDICATOR, LOWER SHELL AND ACCESS DOOR, IMPELLER, IMPELLER DRIVE ASSEMBLY, AND SECURITY RING SEE FIG.

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.

More information

Customized HP100 Sensors. HP300 Series. Customized to solve difficult application problems

Customized HP100 Sensors. HP300 Series. Customized to solve difficult application problems Customized HP00 Sensors HP00 Series Customized to solve difficult application problems The HP00 Series: Are you faced with any of these problems? Tightly mounted thru-scan sensors interfere with each other,

More information

Project: Client: Part #: NEON -P ARC 24VDC WHT lc con cab. Date: Qty: Length CST Custom Length cuttable every 2.81 Operating Voltage (ov)

Project: Client: Part #: NEON -P ARC 24VDC WHT lc con cab. Date: Qty: Length CST Custom Length cuttable every 2.81 Operating Voltage (ov) LED Neon Light Arch LED Neon Light Arch Length CST Custom Length cuttable every 2.81 Operating Voltage (ov) 24V DC Finish (fin) WHT White 2700K Incandescent White 3000K Warm White 3500K Sand White Light

More information

KRPA, KRP, KA, KR series

KRPA, KRP, KA, KR series Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting

More information

Medium-base Lampholders

Medium-base Lampholders Medium-base Lampholders For HID Lamps Medium-base lampholders Material: porcelain, white Nominal rating: 4A/250V/5kV pulse rated Terminals: bushings with set screws 18 14AWG solid Screw shell insert: zinc-plated

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION 1.0 SCOPE This Product Specification covers the 1.27 mm (.050 inch) centerline (pitch) printed circuit board (PCB) modular jack connector series with selective gold and tin plating. 2.0 PRODUCT DESCRIPTION

More information

Mongoose PT Platform Shale Shaker

Mongoose PT Platform Shale Shaker Mongoose PT Platform Shale Shaker (UL VERSION) Revision: A By: MT Mongoose Platform Page 1 of 10 NOTE: Mongoose PT Platform Shale Shaker The attached is a reference to M-I SWACO s STANDARD Mongoose Platform

More information

Variable Transformers Product Design & Engineering Data

Variable Transformers Product Design & Engineering Data Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,

More information

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder Rotary Encoder New General-purpose Incremental Rotary Encoder A wide operating voltage range of 5 to 24 VDC (open collector model). Resolution of 2,000 pulses/revolution in 40-mm housing. can be adjusted

More information

PROXIMITY SENSOR TERMINOLOGY

PROXIMITY SENSOR TERMINOLOGY Never use this desk reference for installation or operation of equipment. Refer to manual for installation and operation instructions. The following descriptions refer to the European standard EN 60947-5-2.

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use andhighperformance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

SECTION 4 OPERATION. Reclining the Chair WARNING

SECTION 4 OPERATION. Reclining the Chair WARNING SECTION 4 OPERATION WARNING After ANY adjustments, repair or service and BEFORE use, make sure that all attaching hardware is tightened securely - otherwise injury or damage may result. CAUTION Ensure

More information

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder A Miniature Power Relay Equipped with arc barrier. Dielectric strength: 2,000 V. Built-in diode models added to the LY Series. Single-pole and double-pole models are applicable to operating coils with

More information

NEMA Contactor and Starter Specifications

NEMA Contactor and Starter Specifications Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental