ø30 ARN/ARNS Series Mono-lever Switches Switches
|
|
- Winifred Houston
- 5 years ago
- Views:
Transcription
1 ø0 ARN/ARNS Series Mono-lever Switches Switches Single lever offers up to four directions of control Mono-lever switches operate in four directions using a single lever. Switch contacts are actuated in the direction in which the lever is pushed, enabling quick and accurate control in any desired direction. Ideal for machine tools and industrial machines. The lever action can be maintained or spring-returned in any combination. Also available with interlock mechanism to prevent inadvertent actuation. Applicable Standards Mark File No. or Organization UL 0 UL Listing File No. E A C. No. A File No. LR GB0. Contact IDEC for details. Specifications and Ratings Contact Ratings by Utilization Category Rated Insulation Voltage 00V Rated Continuous Current 0A Operational Voltage V V 0V 0V 0V 0V AC AC- Control of resistive loads and solid state loads 0A 0A 0A A A Operational 0/0 Hz AC- Control of electromagnetic loads (> VA) 0A A A A A Current DC- Control of resistive loads and solid state loads 0A A.A.A DC DC- Control of electromagnets A A.A 0.A Note: The operational current represents the classification by making and breaking currents (IEC 0--). Specifications Contact Configuration Operating Temperature Storage Temperature Operating Humidity Insulation Resistance Dielectric Strength Mechanical Life Electrical Life Lever Knob Weight (approx.) Double-break slow action Each contact block contains two independent contacts (NO, NO-NC, NC) Up to four contact blocks can be mounted to +0 C (no freezing) to +0 C (no freezing) to % RH (no condensation) 00 MΩ minimum (00V DC megger) Between live and dead parts:,00v AC, minute 00,000 operations minimum (Interlocking: 0,000 operations minimum) Black g (ARN--0000) BR Contact Block The contact block is made of nylon resin. Each contact block contains two pairs of double-break silver contacts. There are three types as shown in the diagram below and up to four contact blocks can be mounted in any direction. A wide vari ety of circuits allows diverse combinations of control. Control Mechanism When the operator lever is pushed to about 0 in each direction from the neutral position, the contact in that direc tion activates. The lever can operate in two, three, or four directions, and combinations of maintained or spring-return from any position are possible.
2 ø0 ARN/ARNS Series Mono-lever Switches Mono-lever Switches Operator Position Lever Action Part No. Dimensions (mm) ARN (Long Lever) ARN-00-➃B M. Terminal -position Screw (Up-Down) ARN-00-➃B ARNS (Short Lever) ARNL (Interlocking) -position (Left-Right) -position (Up-Down-Left-Right) -position (Up-Down) -position (Left-Right) -position (Up-Down-Left-Right) -position (Up-Down) ARN-00-➃B ARN-00-➃B ARN--➃B ARN--➃B ARNS-00-➃B ARNS-00-➃B ARNS-00-➃B ARNS-00-➃B ARNS--➃B ARNS--➃B ARNL-00-➃B ARNL-00-➃B block:, blocks: 0 blocks:, blocks: Panel Thickness 0. to ø Minimum horizontal/vertical mounting centers: 0 M. Terminal Screw ø 0 0 block:, blocks: 0 blocks:, blocks: Minimum horizontal/vertical mounting centers: 0 ø Panel Thickness 0. to ø 0 M. Terminal Screw Panel Thickness 0. to 0 0 -position (Left-Right) ARNL-00-➃B ARNL-00-➃B ø 0 ø The operator lever is locked only in the center position. -position (Up-Down-Left-Right) ARNL--➃B ARNL--➃B block:, blocks: 0 blocks:, blocks: Minimum horizontal/vertical mounting centers: 0 Specify Contact Configuration from the table below in place of ➃. Terminal covers are ordered separately. Lever Operator Position Up Panel Cut-Out ø0. R0. max Mono-Lever with Terminal Cover Right Left Down Ordering Information When ordering, specify items ➀ to ➄ according to the following example. [Example] ➀ Model ARN ARNS ARNL ➀ ➁ ➂ ➃ ➄ ARN B ➁ No. of Contact Blocks : block : blocks : blocks : blocks ➂ Lever Action Order of Entry: Up Right Down Left : : 0: Blocked Up Right Down Left ➃ Contact Arrangement Order of Entry: Up Right Down Left 0: NO 0: NC : NO-NC 0: NO 0: NC 00: Blocked ➄ Lever Knob Color B: black Contact Block Position Terminal No. Direction of Lever Operation Lever Operation Mode : : 0: Blocked 0 NO NC NO NO NO 0 NC NC NC : Contacts marked with do not operate. Terminal No. Contact Block Type BR-E BR-E BR-E BR-E To calculate the number of contact blocks required, add the number of NO and NC contacts on each pair of adjoining positions (up + right, right + down, down + left, and left + up). The largest of the four sums is the number of contact blocks required. Up to four contact blocks can be mounted. Specify the same number of contacts for the contact blocks of opposing corner (up-down, right-left), except for the blocked direction. When UL and A markings are required on the mono-lever switch, specify as shown below. [Example] ARN B- U
3 ø0 ARN/ARNS Series Accessories and Replacement Parts Accessories and Maintenance Parts Shape Specification Part No. Ordering No. Package Quantity Description 0 MLO Nameplate ø0. 0 MLO Chrome-plated brass (matte surface) MLOPN0 0 Terminal Cover ARN-VL ARN-VL Terminal covers are ordered separately. When ordering, specify the Part No. and the required quantity. Order pieces for each contact block. BR-E BR-E NO contact Contact Block (BR) BR-E BR-E NO-NC contact BR-E BR-E NC contact Bellows ARN-BL ARN-BL For ARN/ARNS (Locking ring not included) Bellows (Interlocking) ARNL-BL ARNL-BL For ARNL (Locking ring not included) Knob ARNB- ARNB- Specify a color code in place of ➀. B (black), G (green), R (red) For ARN/ARNS
4 ø0/ø Series Cam Switches standard circuits to choose from Wide variety of heavy-duty oiltight cam switches Operators available up to positions Contact blocks rated at 00V, 0A Ideal for ammeter/voltmeter applications UL listed and A approved Applicable Standards Mark File No. or Organization GB0. CCC No.0000 (ANO, ANK) No (ASO, ASK) No (UQO, UQM) (except ASO and ASK) Specifications and Ratings Contact Ratings by Utilization Category Rated Insulation Voltage 00V Rated Continuous Current 0A Operational Voltage V 0V 0V 0V AC AC- Control of resistive loads and solid state loads 0A A A Operational 0/0 Hz AC- Control of electromagnetic loads (> VA) A A A Current DC- Control of resistive loads and solid state loads A A A 0.A DC DC- Control of electromagnets A.A 0.A 0.A Note: The operational current represents the classification by making and breaking currents (IEC 0--). Specifications Double-break slow action contacts Contact Configuration Two contacts in one deck Up to decks available (Spring-return: Up to decks) Operation Angle 0,, 0, 0 Operator Positions to,, Operating Temperature 0 to +0 C (no freezing) Storage Temperature 0 to +0 C (no freezing) Operating Humidity to +% RH (no condensation) Insulation Resistance 00 MΩ (00V DC megger) Dielectric Strength 00V AC, minute (between live and dead parts) Mechanical Life to decks: 00,000 operations to decks: 00,000 operations Electrical Life 00,000 operations minimum ANO, ASO: IP (IEC 0) Degree of Protection ANK, ASK: IP (IEC 0) U: IP0 (IEC 0) Weight (approx.) g (ANO--SB) B Contact Block The B contact block contains two poles of double-break contacts. The contacts are operated by a cam designed to perform a required contact operation. Up to six contact blocks can be mounted on a maintained-action operator base, and up to three contact blocks on a spring return operator base. M. Screw Terminal 0
5 ø0/ø Series Cam Switches Cam Switches ø0 Series ➀ Model ø Series ➁ Contact Block Decks ➂ Positions ➃ Angle ➄ Spring Return ➅ Handle ➆ Contact Arrangement Nameplate ANO ASO to decks : to decks to positions : to positions 0,, 0, 0 : only from right from left two-way Y, S, P, F, S (S is for ASO only) (one specified handle supplied) (Photo: ANO with Y handle) ANK ASK See page. (ordered separately) H Handle Key (black) to decks : to decks to positions : to positions, 0 : only from right from left two-way Two standard keys are supplied. When the H key handle is required, specify H. See page to. Standard Key ( keys supplied) UQO (Enclosed) to decks : to decks to positions : to positions 0,, 0, 0 : only from right from left two-way Type CQ See page 0. (Photo: With Y handle) UQM (Enclosed) Y, S, F, P (one specified handle supplied) Indicator Left: Green Right: Red Left Right : to decks : positions : only two-way C00 C00 C00 C00 C0 C00 C00 C0 See page to. Type CQM See page 0. Spring Return -way For handles and accessories, see page and. Dimensions ANO/ASO ANK/ASK Panel Cut-out M. Terminal Screw Panel Thickness 0. to M. Terminal Screw Panel Thickness 0. to R0. max ø 0 (S Handle) N+ 0. * Spring Return: N: Number of Contact Blocks N+ * Spring Return: N: Number of Contact Blocks +0. ø. 0 (ASO/ASK) +0. ø0. 0 (ANO/ANK) Minimum horizontal/vertical mounting centers With P handle: With other handles: 0 UQO. Panel Thickness.0 max. -M Screw UQM. Panel Thickness.0 max. -M Screw Panel Cut-out -ø. ø M. Terminal Screw N+ Spring Return: N: Number of Contact Blocks All dimensions in mm. (Y Handle) 0 M. Terminal Screw N+ N: Number of Contact Blocks 0 (P Handle) 0 Minimum horizontal/vertical mounting centers With P handle: With other handles: 0
6 ø0/ø Series Cam Switches Ordering Information When ordering, specify items ➀ through ➆ as the designation example below. ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ Contact Block Key irremovable Positions Angle Spring Return Handle Decks position Model Circuit No. ➀ ANO ANK ASO ASK UQO UQM ➁ ➂ ➃ ➄ Decks Code Positions Code Angle Code Return Code 0 RO from left 0 OR 0 from right RR two-way deck decks decks decks decks decks : to decks only positions positions positions positions positions positions positions positions 0 positions positions positions : to positions only 0 ANK/ASK: and 0 only : only code is required only for spring return. ➅ ➆ ➇ (Code) Y, S, P, F, H, S (Color) B: Black See table below. S is for ASO only. Standard ANK/ ASK: no specification required For ANK/ ASK, specify the code(s) of irremovable position(s) in numerical order. For standard contact configurations, use des ignation code on pages to. For custom contact configurations, use the Custom Contact Configuration Specification Sheet on page. Designation Example UQO - RR - SB - C00 ➀ ➁➂➃➄ ➅ ➇ ANO - RR - YB - MAU-C00-ZT ➀ ➁➂➃ ➄ ➅ ➇. When a special contact configuration is required, specify the contact configuration using the Custom Contact Configuration Specification Sheet on page.. A specified handle is attached.. Accessories such as nameplates and jumpers are sepa rately ordered.. The key of the key operated cam switch is removable at every position unless otherwise specified. The key is irremovable at return position. The return and irremovable positions must be specified in Part No. Positions at 0 from irremovable positions are also irremovable. Example: -positions, spring return from right, irremovable at positions and ANK-OR--C0 Handle Designation Code Shape Code Color ø, ø0 Y Handle 0 Y 0 ø, ø0 S Handle S 0 ø, ø S Handle 0. 0 S 0 ø, ø0 P Handle B: black 0 0 P 0 ø, ø0 F Handle 0 ø0 F ANO ASO UQO UQM ASO ANO ASO UQO UQM Applicable Cam Switch Spring Return Operation Available combinations of operator positions, angles, and return directions are listed in the table below. Positions -position -position -position -position From Left From Right From Left From Right Two-way From Left From Right Two-way Return Direction Key Handle 0 0 H ANK ASK ➂ ➃ ➄ Codes RO OR RO OR RR RO OR RR Applicable Cam Switches ANO, ASO, ANK, ASK, UQO UQM Contact Block Decks to decks Note: do not require spring return code ➄.
7 ø0/ø Series Accessories and Replacement Parts Accessories and Replacement Parts Jumper CJ- CJ- Rubber Boot Shape Material Part No. Ordering No. Metal (copper) Package Quantity CJ- CJ-PN0 0 CJ- CJ-PN0 0 Remarks For connecting terminals of adjoining contact blocks For connecting terminals of the same contact block Nitril rubber CR- CR- For preventing ingress of dust into the contact blocks Not applicable for the UQO and UQM Terminal Cover Supplied with selftapping screws for mounting -VL-S -VL-S For to decks of contact blocks Plastic (PPE) -VL-S -VL-S For to decks of contact blocks -VL-S -VL-S ø, ø0 Y Handle 0 Shape Material (Color) Part No. Ordering No. Package Quantity Polybutylene terephthalate (Black) H-YB H-YB 0 ø, ø0 S Handle Polybutylene terephthalate (Black) H-SB H-SB 0 ø S Handle. 0 0 Phenol resin (Black) H-SB H-SB 0 ø, ø0 P Handle ø, ø0 F Handle 0 ø0 0 Phenol resin (Black) H-PB H-PB Bakelite (Black) H-FB H-FB Key Handle 0 Phenol resin (Black) H-HB H-HB Spare Keys Metal (brass nickel-plated) H-K0 H-K0PN0 Handle Shaft Polyamide -HFC -HFCPN0 Handle Screw Handle Screw For Y, ø0 S, and ø S handles M For P and F handles M -SCW-M- -SCW-M-PN0 0 -SCW-M- -SCW-M-PN0 0
8 ø0/ø Series Instructions Instructions Installing the Terminal Cover for the series Cam Switches Complete wiring before installing the terminal cover on the bottom plate of the contact block. The terminal cover has six holes. Of the four round holes at four corners, use two diagonal pair of holes to install the terminal cover. Either pair can be used. Insert the attached self-tapping screws into the pair of holes and tighten the screws to a torque of 0. to.0 N m. For through decks of contact blocks, use terminal cover -VL- S. For through decks of contact blocks, use terminal cover -VL- S. The -VL-S consists of the -VL-S and a termi nal cover for the fourth through sixth decks. Combine the two parts together as shown. Note that once combined, the two parts cannot be separated. Minimum Mounting Centers for Installing the Terminal Cover 0 mm min. (P handle: mm) Mounting Hole Bottom Plate Self-tapping Screw (attached) Insert the screws into a diagonal pair of holes. 00 mm min. (P handle: mm) Although the minimum mounting centers are 00 mm hori zontally and 0 mm vertically, determine the mounting cen ters in consideration of convenience of wiring. For the P handle, the minimum mounting centers are mm hori zontally and vertically. Mounting Hole -VL-S -VL-S For through decks of contact blocks (-VL-S) Terminal Cover Dimensions. (-VL-S). (-VL-S) (-VL-S). (-VL-S). (-VL-S). (-VL-S) N+ 0.. (N: Number of Contact Blocks) All dimensions in mm.
9 ø0/ø Series Instructions Standard Contact Configurations The following table lists standard contact configurations for easy designation of required cam switch operation. When other contact configurations are required, specify the number of contact block decks, operator positions, angles, and contact operation using the Custom Contact Configuration Specification Sheet on page. Symbol RR C00 Contacts closed. No. of Decks: Position: -position Angle: Spring Return: -way Circuit No. Contact Operation The standard contact configurations are listed in the order of the circuit number. Same Circuits Shown in the following examples, circuits of Fig. and Fig. have the same functions. When ordering, examine the standard contact configurations. Your requirements may be satisfied simply by changing external wiring of the stan dard contact configurations. Example Fig. Fig. Example Fig. Fig. Terminal Numbers The terminal numbers on the contact blocks correspond with the numbers shown in the chart as shown below. Terminal No. ➅ ➁ Operator Position ➄ The arrow shows the spring return direction. ➀ ➃ ➆ ➂ Terminal No. Operator Position Contacts remain closed between two operator posi tions. Terminal No. Listing Order of the Table Overlapping Contacts Contacts of different decks are both closed at one point while the handle is turned to the next position. Residual Contacts When the handle is returned to the center, the con tacts remain closed. The contacts are opened when the handle is turned to the opposite direction. Standard Contact Configuration Chart C00 C00 OR C00 OR C00 C00 C00 RR C00 RR C00 RR C00 RR C00 C0 C0 C0 OR C0 C0 C0 RR C0 C0 C00 C00 C00 C00 C00
10 ø0/ø Series Instructions RR C00 RR C00 C00 C00 C0 C0 C0 C0 C0 (O) (R) (S) (T) C0 C00 RR C0 C0 C0 C0 C0 (R) (S) (T) C00 C00 C00 C00 C C00 C00 C00 C0 C0 0 (O) (RS) (ST) (TR) C0 C0 C0 C0 C C0 C00 C00 C (O) (R) (S) (T) C00 C00 C00 C00 C (O) (R) (S) (T) 0 0 0
11 ø0/ø Series Instructions C00 C00 C00 C C00 C00 C00 C00 (O) (R) (S) (T) (RS) (ST) (RT) (RE) (SE) (TE) 0 0 Application Examples (Voltmeter and Ammeter Circuits) C0 (ammeter switching, CT circuit) C0 (ammeter switching, CT circuit) C0 (ammeter switching, CT circuit) CT E A R S T R S T CT E A R S T O R S T CT E C0 (voltmeter switching, PT circuit) C00 (voltmeter switching, PT circuit) C00 (voltmeter switching, PT circuit) A R S T E PT ø-w V R S T PT O RS ST TR V R S T E 0 PT ø-w 0 V C00 (ammeter switching, CT circuit) C00 (ammeter switching, CT circuit) C00 (ammeter switching, CT circuit) CT R S T O R S T 0 0 A CT R S T E O R S T 0 A CT R S T E O R S T 0 A E
12 ø0/ø Series Instructions Custom Contact Configurations Specification Sheet The preceding pages provide standard contact configurations. When other contact configurations are required, specify the number of contact block decks, operator posi tions, angles, and contact operation using the Custom Contact Configuration Specification Sheet shown below. For available number of contact blocks and operator posi tions, see the Ordering Information on page.. Specify operator positions Indicate the operator positions starting at the first position. When spring return operation is required, mark an arrow between two operator positions to indicate the spring return direction. Deck Deck Angle Positions Spring Return. Specify contact operation at each operator position Indicate the required operation of all contacts at each operator position using the following symbols. Symbol Contact Operation Contacts closed. Contacts remain closed between two operator posi tions. Overlapping Contacts Contacts of different decks are both closed at one point while the handle is turned to the next position. Overlapping contacts are not available for handle angles of 0 and. Residual Contacts When the handle is returned to the center, the con tacts remain closed. The contacts are opened when the handle is turned to the opposite direction. One deck of contact block contains two poles of contacts and four terminals. When the handle is made to turn 0 or more, special attention is needed. Since one cam oper ates the two poles of contacts on opposite positions, the same contact operation repeats on the other pole of con tacts when the handle is turned 0. When different con tact operation is needed for handle angles of 0 or more, use another deck of contact block. Series Cam Switch Custom Contact Configuration Specification Sheet Part No.: ➀ Model ➁ Decks ➂ Positions ➃ Angle ➄ Spring Return ➅ Handle Quantity: Deck Terminal No. Contact Configuration Chart Terminal No. Deck Deck Deck Deck Deck Deck 0 0 Angle Positions 0 Spring Return
Switches & Pilot Devices
ø0mm - Series Key features: Wide variety of heavy-duty oiltight cam switches Operators available up to positions Switches made with a double circuit contact block Contact blocks rated 00V, 0A Ideal for
More informationRelays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:
RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator
More informationRU Series Universal Relays
Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal
More informationRelays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection
RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More information[3] MOUNTING DIRECTION
Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced
More informationPosition switches FM series
B Position switches FM series Selection diagram 0 08 0 A A 0 A 0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket 69 stainless steel round rod square rod fiber
More informationRelays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive
RFV RFV -Pole Force Guided Relays/SJ Series Relay Sockets Key features: -pole force guided relay to reduce cost and installation space. Force guided contact mechanism (EN00 Type A TÜV approved). Reinforced
More informationSafety switches with slotted hole lever
Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the
More information22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection
Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety
More informationLR Position Switches TECHNICAL DATASHEET
TECHNICA DATASHEET Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 69 contact blocks available actuators available M assembled connector versions Silver
More informationA W - A 2A R - 24D - 1
Knob-type Selector Switch A165S/W Mounting Aperture of 16 mm Modular construction Oil-resistant IP65 models UL and cul approved. Conforms to EN60947-5-1, IEC947-5-1 Short mounting depth, less than 28.5
More informationRatchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj
Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input
More informationInductive Proximity Sensor
Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of
More informationRelays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal
RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT PDT PDT RH Series Compact
More informationFM series position switches
FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass
More informationOperating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)
Built-in Amplifier Photoelectric Sensor E3S-A/B Revolutionary High-performance High-quality Sensor with Built-in Amplifier can be adjusted in seconds because the optical axis coincides with the mounting
More information800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)
1-,, 3-, 4- Toggle Switches (Bul. 800T only) 800T T2 H2 E E X X a b c d e f g Right Left Right Left Blank C T1 T2 T3 T4 a Finger-Safe Guards Description No guards Guards on terminals b Operator Type Description
More informationData Sheet. Summation Current Transformer OMEGA SUMMATION CT : SIGMA SERIES. Page 1 of 5 00 / 1213
OMEGA SUMMATION CT : SIGMA SERIES Data Sheet Summation Current Transformer Page 1 of 5 Omega Summation current transformers are designed to summarize several synchronous Alternating Currents of equal phase
More informationRJ Series Slim Power Relays
RJ Series RJ Series Slim Relays Circuit Breakers Terminal Blocks Timers Display Lights Switches & Pilot Lights Compact and rugged power relays. Large switching capacity. Compact housing only.7-mm wide.
More informationRU Series. Full featured universal miniature relays. Designed with environment taken into consideration.
Universal Series Safety The contact position can be confirmed through the five small windows. Using the latching lever, operation can be checked without energizing the coil. The latching lever is color
More informationTOGGLE SWITCHES IP67 A 9 SERIES 1B AGENCY APPROVALS SPECIFICATIONS
AGENCY APPROVALS SPECIFICATIONS Sealed miniature toggle switches C IP67 File N E195524 File N E195524 In conformity with: EN 60529: 1991 IEC 529: 1989 CHARACTERISTICS Contact Rating: S (silver) - 5A with
More informationUNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550
UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY K-RELAYS.0 a UL File No.: E3 CSA File No.: LR2550.0.8 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical
More informationEasy to replace. A pigtailed type sensor with connector (CY- -J), which is easy to replace, is also available. Environment resistant
EQ- VF NX PM PM MS-AJ RT-6 PX- PHOTOELECTRIC SENSORS Mounting Stand SERIES Cylindrical Photoelectric Test input PNP output Light intensity type available monitor M This sensor has an M size for convenient
More informationOvertravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0
Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.
More informationE2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)
Cylindrical Proximity Sensor in Plastic Housing High quality full body plastic housing for high water proof requirements Polyarylate housing for light chemical resistance Applications Detection of bottle
More informationELECTRIC ACTUATOR. Quarter turn(rotary type) - ZGQ Series
ELECTRIC ACTUATOR Quarter turn(rotary type) - ZGQ Series Construction (Inside) - Manual handle - Limit switch cam - Limit switch - Stopper - Cable entries - Valve bracket - Indicator - Motor (Reversible
More informationIDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)
IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact
More informationMINIATURE RELAY FOR WIDER APPLICATIONS
TÜV Rheinland HJ MINIATURE RELAY FOR WIDER APPLICATIONS HJ RELAYS FEATURES contact arrangements Form C (for A 0 V AC), Form C (for 0 A 0 V AC)* Excellent contact reliability by Au plating Environmentally
More informationCylindrical Photoelectric Sensor
SERIES Cylindrical Photoelectric Amplifier Built-in Cylindrical type easily mountable with M Conforming to EMC Directive AC supply type conforms to Low Voltage Directive, too. ( ) UL Recognition M This
More informationNA DigiParts GmbH. Small / Slim Object Detection Area Sensor
953 PHOTO PHOTO MEASURE ITY Object Area Sensor General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Cross-beam scanning system to detect slim objects Letters or business
More informationBulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.
Bulletin H Product verview/specifications Bulletin H/ Hazardous locations push buttons and stations Classes I, II & III Divisions & / in. - NPSM barrel Type & Explosion-proof operators Table of Contents
More informationNA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable!
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationSB 50 Connectors - up to 120 amps
Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP s two pole SB connectors set the standard for DC power distribution and battery connections. connectors feature a one
More informationComponents for safety applications
Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages
More information6mm Interface Relays RV8 Series
6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.
More informationAFTER SELECTING THE PRODUCT YOU REQUIRE, PLEASE ADD THE FOLLOWING: 4. CAM DETAILS... SEE AND PRODUCT DATA SHEET FOR DETAILS
Furniture Locks Specifying a product when ordering AFTER SELECTING THE PRODUCT YOU REQUIRE, PLEASE ADD THE FOLLOWING: 1. REMOVABLE BARREL SYSTEM.. PAGES 4.10-4.49 2. FIXED BARREL PRODUCTS... PAGES 4.50-4.99
More informationTURQUOISE SWITCHES ABS TYPE
HIGH ENVIRONMENTAL RESISTANCE VDE TURQUOISE SWITCHES ABS TYPE 11.1 19.3 FEATURES Subminiature size (19.8 11.1 ) Sealed construction for use in adverse environment-sealed construction by epoxy resin and
More informationSMT TR series. Surface mount tiny washable rocker switches. Distinctive features and specifications.
SMT TR series Surface mount tiny washable rocker switches istinctive features and specifications Entirely designed for surface mount Tape and reel packaging Reflow solderable High temperature plastic materials
More informationTimers GE1A. GE1A Series ON Delay Timers Single Function
Key features: DPDT or SPDT + instantaneous SPDT 8-pin, octal base 8 time ranges Repeat error ±0.2% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators
More informationGT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC
TY Series TY Series ON Delay Key features of the TY series include: PDT, 3A or DPDT, A contacts time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED
More informationUSA series. Capable of long-distance measurement Built-in teaching function for simple operation and highlyaccurate
series Ultrasonic displacement sensors (3m Type) Capable of long-distance measurement Built-in teaching function for simple operation and highlyaccurate measurement Integrated temperature sensor for stable
More informationHigh Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance
13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO
More informationHG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS
20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,
More informationTURQUOISE SWITCHES ABV TYPE
HIGH ENVIRONMENTAL RESISTANCE VDE TURQUOISE SWITCHES ABV TYPE 33.0.3 FEATURES Miniature size (33.3 ) Sealed construction for use in adverse environment-sealed construction by epoxy resin and rubber cap
More informationE3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features
bottle sensor Ideal for detecting transparent glass and plastic containers Features Stable operation even if container interval is shortened for higher productivity. Stable detection of 5 mm gaps that
More informationDistributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility
More informationGT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814
TW Series Courtesy of Steven Engineering, Inc. 0 Ryan Way, South San Francisco, CA, 00-70 Main Office: (50) 5-00 Outside Local Area: (00) 5-00 www.steveneng.com Specifications Time Range Rated Voltage
More informationStandard C800 16A Switches & CBN800 Switches from 10 ma
Offer Standard C A Switches & CBN Switches from ma General Characteristics These switches are designed for currents ranging from ma to ma, and voltages from V to V, depending on the type, standard C, or
More informationSS-A5 SERIES SH SERIES
395 Manually Sensitivity Set Photoelectric Sensor SS-A5 SERIES SH SERIES Amplifi er-separated General terms and conditions... P.1 Sensor selection guide...p.11~ / P.9~ Related Information SH Specifications
More informationEnclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI
General-purpose Relay CSM_GR-_-S_DS_E Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped
More informationDetecting Devices. 8/2 Introduction
Siemens AG 29 Detecting Devices /2 Introduction 3SE5, 3SE2, 3SE3 Position Switches /4 General data /11 3SE5, plastic and metal enclosures /2 3SE2, plastic enclosures /26 3SE2, metal enclosures /36 3SE3,
More informationCharlie. Pendant control station. Industrial lifting. Construction lifting. Stage technology. Industrial automation
Charlie Pendant control station Charlie pendant station is a control device for all industrial machinery. It operates as an auxiliary controller of electrical motors through a power interface, such as
More informationModel Number Structure
General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long
More informationOMRON MK-I / -S RELAY
Issued April 0 0 DATA SHEET OMRON MK-I / -S RELAY Based on OMRON Datasheet General-purpose Relay MK-I/-S 0 Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks
More informationEmitting and receiving element pitch: 10 mm in
Small / Slim Object Detection Area Sensor Cross-beam scanning system to detect slim objects Letter or visiting card detectable! Slim objects can be detected by using the cross-beam scanning system. Emitting
More informationEmitting and Receiving Element Pitch: 10mm
Small/Slim Object Detection Area Sensor Cross-beam Scanning System to Detect Slim Objects Marked Conforming to EMC Directive Letter or Visiting Card Detectable! Slim objects can be detected by using the
More informationPosition switches FR series
B Position switches FR series Selection diagram 0 A 0 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket
More informationHigh Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance
1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global
More informationHARTING Han GND. People Power Partnership
98 42 937 0201 HARTING Han GND People Power Partnership Han GND - Mateable Potential Equalization The new Han GND series now enables pluggable grounding systems Han GND (Han Ground) is the innovative HARTING
More informationQFM21... Duct sensors. Symaro. for relative humidity and temperature
1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10
More information12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.
96 PHOTO PHOTO ON/OFF Input SERI Related Information General terms and conditions... F-3 General precautions... P.9 MEASURE panasonic.net/id/pidsx/global Multi-functional D rail mounting slim sensor controller
More informationAccessories. Accessories
Accessories Accessories Voltage transformer Voltage transformer Powerful and precise Input, 3-pole Output is 3-pole + N Use in IT networks without neutral line For reducing the measurement voltage for
More informationRT-3 UNIT RELAY 4-POINT TERMINAL
Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More informationUNIQUELY DESIGNED RELAY FEATURES
UL CSA VDE Pending Pending Pending UNIQUELY DESIGNED RELAY K-RELAYS a.8 FEATURES 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical ( A V): more
More informationDetecting Devices. 8/2 Introduction
Detecting Devices /2 Introduction /4 General data / 3SE5, plastic enclosures /16 3SE2, plastic enclosures /22 3SE5, metal enclosures /30 3SE2, metal enclosures /39 3SE3, metal enclosures Compact design
More informationTL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models
Standard Flat Inductive Proximity Sensors Front and side facing surface IP67 DC -wire and DC -wire models Ordering Information DC -wire Models Shape distance Model Output and operating status mm MD1 *1
More informationPhotoelectric Sensor
Photoelectric Sensor Revolutionary High-performance High-quality Sensor with Built-in Amp can be adjusted in seconds because the optical axis coincides with the mounting axis. Highly visible spot on white
More informationNA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects
929 PHOTO PHOTO MEASURE Object Area Sensor General terms and conditions... F-3 Related Information Glossary of terms... P.1549~ panasonic.net/id/pidsx/global guide...p.85~ General precautions... P.1552~
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationEX-40 SERIES. Convergent Reflective Photoelectric Sensor. Reliable object detection in limited area. Stable convergent distance sensing
313 PHOTO PHOTO Convergent Reflective Photoelectric EX-4 SERIES Related Information General terms and conditions... F-3 Glossary of terms / General precautions...p.1549~ / P.1552~ guide... P.231~ Korea
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationType Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1
Slim Relays with Forcibly Guided Contacts Conforming to EN Standards EN50205 Class A, approved by VDE. Ideal for use in safety circuits in production machinery. Four-pole and six-pole Relays are available.
More informationonlinecomponents.com
Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common
More informationTriple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in
377 PHOTO PHOTO USE MEASUREMENT STATIC CONTROL Triple Beam Adjustable Range Reflective Photoelectric SERIES Related Information General terms and conditions... F-17 Glossary of terms... P.1359~ selection
More informationTimers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range
GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,
More informationCylindrical type proximity sensor
Cylindrical type Cylindrical type proximity Features Improved the noise resistance with dedicated IC Built-in reverse polarity protection circuit (DC 3-wire type) Built-in surge protection circuit Built-in
More informationData Sheet. Summation Current Transformer. RISH SUMMATION CT : RISH XMER Sigma. RISH XMER Sigma. Page 1 of 5 00 / 1213
RISH SUMMATION CT RISH XMER Sigma Data Sheet RISH XMER Sigma Summation Current Transformer Tel. +91 253 2202160, 2202202 Fax +91 253 2351064 E-mail India - marketing@rishabh.co.in International - exp.marketing@rishabh.co.in
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationType Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
More informationHigh Reliability Of Fiber Optic Amplifier For Convenient Mounting
Amplifier Reliability Of Amplifier For Convenient Mounting Features speed response: Max. 0.5ms Auto (Button setting)/remote synchronization input, mutual interference protection, selfdiagnosis Reverse
More informationSUPER-SLIM PHOTOELECTRIC SENSORS. The sensor is suitable to detect small and high-speed traveling objects.
SUPER-SIM PHOTOEECTRIC SENSORS UZB1/2 series AMPIFIER BUIT-IN EXTRAORDINARIY DOWN-SIZED The Smallest Body Just mm inch Thick High-speed Response Time :.5ms Flexible Mounting Just W1H1.5Dmm W.39 H.571Dinch
More informationNo-wear isolation of potentials in terminal block design
TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly
More informationTriple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global
337 Triple Beam Adjustable Range Reflective Photoelectric SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1549~ guide... P.231~ General precautions... P.1552~ PHOTO
More informationInstallation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602
596 597 Installation Tools Pipe Cutters for steel and cast iron pipes 598 Pipe Cutters / Pipe Deburring Reamer for stainless steel pipes 600 Pipe Cutters / Pipe Deburring Reamer / Calibrating Tool for
More informationPRODUCT SPECIFICATION
2.54mm Board to Board Header Connectors Page 1 1.0 SCOPE This specifies Pitch 2.54mm Headers Connectors. The connector shall meet the performances, specified here under the condition with the plug connector
More informationTL series Tiny washable toggle switches
Distinctive features and specifications Sealed Single piece case O-ring seal between actuator and bushing Epoxy sealed terminals Wide variety of contact materials Same PCB layout as TP, TR and TG tiny
More informationAmplifier-separated Manual Sensitivity Setting Photoelectric Sensor
-separated Manual Sensitivity Setting Photoelectric Sensor Twin Adjuster Enables Delicate Sensitivity Setting Twin Adjuster Its twin adjuster enables easy optimum setting to suit the application. Twin
More informationRectangular Type APS-S/M Series
APS-CU APS- 5 APS-F/U APS-S/M APS-CK APS-0/ APS-GK APS-GM APS-GMD APS-GMC Small design offered in two types: front face sensing and upper sensing. Different-frequency type that allows close-contact installation.
More information30 AMP POWER RELAY WITH SPACE SAVING DESIGN
VDE 3 AMP POWER RELAY WITH SPACE SAVING DESIGN JH-RELAYS 2..2 3.. FEATURES Many safety-oriented characteristics incorporated Contact gap: more than 3 mm. inch for Form A and 2 Form A Breakdown voltage
More informationMonitoring voltages of 3-phase 4 wires with a single unit
VOLTAGE RELAY PTS TYPE High-performance under-voltage relay that activates output when all 3-phase voltages fall below a reference voltage by monitoring voltage on each phase of 4 wires FEATURES Monitoring
More informationE2S World's Smallest Square Sensor with Built-in Amplifier
Compact Square Inductive ES World's Smallest Square Sensor with uilt-in mplifier Features 5.5 mm World's Smallest Sensor with uilt-in mplifier The 5.5 mm x 5.5 mm type permits smaller, space-saving machines
More informationSnap Action Switches Technical Guide
These basic principles apply to all our precision switches. The specific characteristics of each model are given in more detail in the relevant production sections. Switch construction Single-pole changeover
More informationE2C-EDA. Proximity Sensor with Separate Amplifier Enables Easily Making Highprecision Sensitivity Settings. Ordering Information
Authorised Distributors:Intech Systems Chennai Pvt. Ltd, Chennai-00 032 Ph: +91 44 4353 Fax: 044 4353 7 E-mail: info@intechchennai.com Website: www.intechchennai.com High Precision Positioning Inductive
More information10. Mini Coax Connectors
. Connectors The allows multi-pole coaxial data transmission for board-to-board, cable-to-board and cable-to-cable applications with protection up to IP 65 / IP 67. At the same time, applications up to
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationCharacteristics 5 TeSys k contactors and reversing contactors
90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More informationMODEL: W2TS. Mini-MW Series
Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization
More information