1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551

Size: px
Start display at page:

Download "1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551"

Transcription

1 .7 Pushbuttons and Indicating Lights Contents escription 30.5 mm Square Multifunction Watertight/Oiltight E30 Product Identification Product Selection Operators Operator Components Accessories Options Replacement Parts Technical ata and Specifications imensions Product escription The E30 industrial pushbutton and indicating light line from Eaton s Electrical Sector features a wide selection of square, multifunction operators which conveniently mount in a standard 30.5 mm (-3/64 in) diameter panel hole. Up to six input and indicating functions can be grouped into a single operating head, saving valuable panel space. Attractive square operator styling, coupled with custom legending of colored buttons and lenses and many special function accessories, makes E30 components ideally suited for use on control consoles and for a variety of industrial OEM applications. Features Type E30 control units consist of a basic operator with one or more buttons and lenses and contact block selection dependent on the specific operator configuration. Pushbutton operators will accommodate up to four single depth stackable contact blocks behind each operating button, up to eight circuits maximum. Indicating lights are supplied complete with either a transformer light unit up to 600 Vac supply line voltage or full voltage light unit up to 20 Vac/Vdc supply line voltage. Combination pushbutton with indicating light operators are supplied complete with a transformer or full voltage unit. Contact blocks must be ordered separately, up to four circuits maximum. ie Cast Construction Each operator has high pressure type seals to prevent the passage of oil and other contaminants through the operator into the contact structure or panel interior. Each operator uses a una N cork gasket between the mounting flange on the operator and the panel to maintain oiltightness. Standards and Certifications Page V7-T-65 V7-T-66 V7-T-6 V7-T-75 V7-T-76 V7-T-7 V7-T-0 V7-T- UL Listed File No. E356 CSA Certified File No. LR655 Ingress Protection Single and dual indicating lights UL (NEMA) Type, 2, 3, 3R, 3S, 4, 4X, 2, 3 All other operators UL (NEMA) Type 3, 3R, 4, 4X, 2, 3 V7-T-64 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March 204

2 Pushbuttons and Indicating Lights.7 Product Identification 30.5 mm Square Multifunction Watertight/Oiltight Multifunction Operator (see Pages V7-T-66 to V7-T-6) uttons and es Supplied lank or with Custom Legend(s) (see Pages V7-T-6 to V7-T-73) Lower Contact lock Operating Plunger Upper Contact lock Operating Plunger Gasket Retaining Nut Secures Operator to Panel Locking Ring Supplied with Operator Serves as Mount for Light Element and Contact locks Quarter Turn Screw Mounts Locking Ring to Operator Transformer or Full Voltage Light Element Supplied with Operator Single Circuit Contact lock Two Circuit Contact lock Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March V7-T-65

3 .7 Pushbuttons and Indicating Lights Product Selection Operators When Ordering a Complete E30 Control Unit Specify of Ordering Example (E30A) Operator E30K30 START utton(s) E30K23 STOP Contact block(s) E30KLA NO Accessories (if required) E30KLA2 NC Square Multifunction Operators UL (NEMA) Type 3, 3R, 4, 4X, 2, 3 Single utton Operator Shown with Extended utton Two utton Operator Shown with Extended uttons Two utton Operator Shown with Long Release ar Single utton Operator/without utton (Order utton Separately) utton Type Required Operation Special Features Momentary E30AA Two utton Operator/without uttons (Order uttons Separately) utton Types Operation Required Top utton ottom utton Special Features Momentary Momentary E30A Momentary Momentary With mechanical E30AC interlock Maintained (all contacts) Maintained (all contacts) Release (all contacts) Release (all contacts) E30A 2 With mechanical interlock E30AP 23 Two utton Operator with Long (OFF) Release ar Includes OFF ar/utton (Order Other uttons Separately) utton Types Required 45 Operation Top utton ottom utton Special Features Maintained Maintained E30AF Maintained Maintained With mechanical interlock Maintained Momentary With mechanical interlock Maintained (all contacts) Maintained (bottom contacts only) Top button operates both top and bottom contacts E30AG E30AH E30AK 6 Notes Order from table on Page V7-T-6. 2 Limited to two single circuit, one double circuit 600V or two 20V (E30KLA) contact blocks behind each button. 3 uttons are interlocked so that one of the two is maintained at all times. epressing the other button releases the maintained button and maintains the depressed button. 4 Operators are supplied as standard with red extended bar(s) marked OFF as shown in sketch. For other colors or markings, contact your nearest Eaton istributor or call our Customer Service Center For replacement of standard red release bar, order E30KR00. 5 Order from table on Page V7-T Limited to two single circuit, one double circuit 600V or two 20V (E30KLA) contact blocks behind each button. V7-T-66 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March 204

4 Pushbuttons and Indicating Lights.7 Square Multifunction Operators and Indicating Lights UL (NEMA) Type 3, 3R, 4, 4X, 2, 3 Two utton Operator Shown with Release ar for Top utton Two utton Operator Shown with Release ars for Each utton Single Indicating Light Unit Shown with ual Indicating Light Unit Shown with Two utton Operator with (OFF) Release Includes OFF ar/utton(s) (Order Other uttons Separately) utton Types Required 2 Single Indicating Light Unit/without (Order Separately) Type of Light Element Type Required 3 ual Indicating Light Unit/without es (Order es Separately) Type of Light Element Types Required 5 Notes Order from table on Page V7-T Operators are supplied as standard with red extended release bar(s) marked OFF as shown in sketch. For other colors or markings, contact your nearest Eaton istributor or call our Customer Service Center For replacement of standard red release bar, order E30KR0. 3 Order from table on Page V7-T-7. 4 Light units will also accept LE lamps. For LE part numbers, see table on Page V7-T-7. 5 Order from table on Page V7-T-72. Operation Top utton ottom utton Special Features Maintained Momentary Release bar for top button Maintained Maintained Individual release bars for each button Maintained with interlock Transformer (60/50 Hertz AC) Maintained with interlock Individual release bars for each button Full Voltage (60/50 Hertz AC or C) E30AL E30AN E30AM Voltage Number 4 Voltage Number PS E30A 24 24PS E30J 20 20PS E30M Transformer (60/50 Hertz AC) Full Voltage (60/50 Hertz AC or C) Voltage Number 4 Voltage Number PS E30CA 24 24PS E30CJ 20 20PS E30CM Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March V7-T-67

5 .7 Pushbuttons and Indicating Lights UL (NEMA) Type 3, 3R, 4, 4X, 2, 3 Single utton Operator and Indicating Light Shown with utton and Single utton Operator with Release ar and Indicating Light Shown with utton and Two utton Operator with Indicating Light Shown with utton and Two utton Operator with ual Indicating Lights Shown with utton and Single utton Operator with Indicating Light/without utton or (Order utton and Separately) utton and Types Required Single utton Operator with (OFF) Release ar and Indicating Light Includes OFF ar/utton (Order Other utton and Separately) utton and Types Required Two utton Operator with Indicating Light/without uttons or (Order uttons and Separately) utton and Types Required 4 Two utton Operator with ual Indicating Lights/without uttons and utton and Types Required Notes Operation (ottom utton) Type of Light Element Transformer (60/50 Hertz AC) Full Voltage (60/50 Hertz AC or C) Voltage Number 2 Voltage Number 2 Momentary 20 6PS E30A 24 24PS E30X PS E30F Operation (ottom utton) Type of Light Element Transformer (60/50 Hertz AC) Full Voltage (60/50 Hertz AC or C) Voltage Number 3 Voltage Number 2 Maintained 20 6PS E30G 24 24PS E30X PS E30M Type of Light Element Transformer (60/50 Hertz AC) Full Voltage (60/50 Hertz AC or C) utton Operation Voltage Number 2 Voltage Number 2 Momentary 20 6PS E30EA 24 24PS E30EX PS E30EF Momentary 20 6PS E30EG 24 24PS E30EX3 with interlock 20 20PS E30EM Type of Light Element Transformer (60/50 Hertz AC) Full Voltage (60/50 Hertz AC or C) utton Operation Voltage Number 2 Voltage Number 2 Momentary 20 6PS E30JA 24 24PS E30JX PS E30JF Order from tables on Pages V7-T-6 to V7-T Light units will also accept LE lamps. For LE part numbers, see table on Page V7-T-7. 3 Operators are supplied as standard with red extended release bar(s) marked OFF as shown in sketch. For other colors or markings, contact your nearest Eaton istributor or call our Customer Service Center For replacement of standard red release bar, order E30KR0. 4 Order from tables on Pages V7-T-7 and V7-T-72. V7-T-6 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March 204

6 Pushbuttons and Indicating Lights.7 Operator Components Operating uttons Only Type A Extended utton Type Extended utton Type A uttons with Standard Markings utton Application Color Marking Extended utton Type uttons with Standard Markings 2 utton Application Color Marking Short utton Color Marking Notes Use with operator E30AA, legend characters 3/6 in (4. mm) high. 2 Use with operators E30A thru AE, AL and A thru F, legend characters 3/6 in (4. mm) high. Extended utton Short utton lack lank E30KA00 E30KA50 Green START E30KA330 E30KA30 START E30KA0 Yellow lank E30KA400 E30KA450 Red lank E30KA200 E30KA250 White lank E30KA500 E30KA550 EMERG. STOP E30KA204 Gray lank E30KA600 E30KA650 OFF E30KA2 E30KA26 rown lank E30KA700 E30KA750 STOP E30KA23 E30KA2 Orange lank E30KA00 E30KA50 Green lank E30KA300 E30KA350 lue lank E30KA00 E30KA50 Extended utton Short utton Color Marking Extended utton Short utton lack lank E30K00 E30K50 lack REVERSE E30K25 E30K75 AUTO E30K0 E30K5 RUN E30K26 E30K76 CLOSE E30K02 E30K52 SLOW E30K2 E30K7 OWN E30K03 E30K53 START E30K30 E30K0 FAST E30K05 E30K55 TEST E30K32 E30K2 FORWAR E30K07 E30K57 UP E30K34 E30K4 HIGH E30K0 E30K5 Red lank E30K200 E30K250 IN E30K0 E30K60 EMERG. STOP E30K204 INCH E30K E30K6 OFF E30K2 E30K26 JOG E30K2 E30K62 STOP E30K23 E30K2 JOG FOR. E30K3 E30K63 Green lank E30K300 E30K350 JOG REV. E30K4 E30K64 START E30K330 E30K30 LOW E30K5 E30K65 Yellow lank E30K400 E30K450 LOWER E30K6 E30K66 White lank E30K500 E30K550 MAN E30K7 E30K67 AUTO E30K50 ON E30K E30K6 HAN E30K50 OPEN E30K20 E30K70 Gray lank E30K600 E30K650 OUT E30K2 E30K7 rown lank E30K700 E30K750 RAISE E30K22 E30K72 Orange lank E30K00 E30K50 RESET E30K24 E30K74 lue lank E30K00 E30K50 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March V7-T-6

7 .7 Pushbuttons and Indicating Lights Type C Extended utton Type C uttons with Standard Markings utton Application Color Marking Extended utton Short utton Color Marking Note Use with operators E30AF thru AK, AL thru AM and G thru M, legend characters / in (3.2 mm) high. Extended utton Short utton lack lank E30KC00 E30KC50 lack RESET E30KC24 E30KC74 AUTO E30KC0 E30KC5 REVERSE E30KC25 E30KC75 CLOSE E30KC02 E30KC52 RUN E30KC26 E30KC76 OWN E30KC03 E30KC53 SLOW E30KC2 E30KC7 FAST E30KC05 E30KC55 START E30KC30 E30KC0 FORWAR E30KC07 E30KC57 TEST E30KC32 E30KC2 HAN E30KC0 E30KC5 UP E30KC34 E30KC4 HIGH E30KC0 E30KC5 Red lank E30KC200 E30KC250 IN E30KC0 E30KC60 OFF E30KC2 INCH E30KC E30KC6 STOP E30KC23 E30KC2 JOG E30KC2 E30KC62 Green lank E30KC300 E30KC350 JOG FOR. E30KC3 E30KC63 START E30KC330 E30KC30 JOG REV. E30KC4 E30KC64 Yellow lank E30KC400 E30KC450 LOW E30KC5 E30KC65 White lank E30KC500 E30KC550 LOWER E30KC6 E30KC66 Gray lank E30KC600 E30KC650 MAN E30KC7 E30KC67 rown lank E30KC700 E30KC750 ON E30KC E30KC6 Orange lank E30KC00 E30KC50 OPEN E30KC20 E30KC70 lue lank E30KC00 E30KC50 OUT E30KC2 E30KC7 RAISE E30KC22 E30KC72 V7-T-70 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March 204

8 Pushbuttons and Indicating Lights.7 Operating uttons and Only Standard Color uttons and Marking lack lettering on White, Amber, Yellow and Clear. White lettering on Green, Red, lue, rown, lack, Orange and Gray. Type E utton Type F Type E uttons with Standard Markings 2 utton Application Color Marking Type F es with Standard Markings 3 Extended utton Color Marking Notes For lenses with special markings or with standard markings but in a different color, refer to instructions on Pages V7-T-76 to V7-T-7. 2 Use with operators E30EA thru EM, FA thru FM and JA thru JM, legend characters / in (3.2 mm) high. 3 Use with operators E30A thru Y, legend characters 3/6 in (4. mm) high. Extended utton lack lank E30KE00 lack RESET E30KE24 CLOSE E30KE02 REVERSE E30KE25 OWN E30KE03 RUN E30KE26 FAST E30KE05 SLOW E30KE2 FORWAR E30KE07 START E30KE30 HIGH E30KE0 TEST E30KE32 IN E30KE0 UP E30KE34 INCH E30KE Red lank E30KE200 JOG E30KE2 OFF E30KE2 JOG FOR. E30KE3 STOP E30KE23 JOG REV. E30KE4 Green lank E30KE300 LOW E30KE5 START E30KE330 LOWER E30KE6 Yellow lank E30KE400 ON E30KE White lank E30KE500 OPEN E30KE20 Gray lank E30KE600 OUT E30KE2 rown lank E30KE700 PHASE E30KE22 Orange lank E30KE00 lue lank E30KE00 utton Application Color Marking Color Marking Red lank E30KF0 Green OFF E30KF22 MOTOR RUN E30KF Amber lank E30KF30 ON E30KF2 lue lank E30KF40 POWER ON E30KF3 Clear lank E30KF50 Green lank E30KF20 White lank E30KF60 MOTOR STOP E30KF2 MOTOR RUN E30KF23 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March V7-T-7

9 .7 Pushbuttons and Indicating Lights Operating Only Standard Color uttons and Marking lack lettering on White, Amber, Yellow and Clear. White lettering on Green, Red, lue, rown, lack, Orange and Gray. Type G Type J Type K es Type G es with Standard Markings 2 Application Color Marking Color Marking Red lank E30KG0 Green OFF E30KG22 MOTOR RUN E30KG REAY E30KG23 ON E30KG2 Amber lank E30KG30 POWER ON E30KG3 lue lank E30KG40 Green lank E30KG20 Clear lank E30KG50 MOTOR RUN E30KG24 White lank E30KG60 MOTOR STOP E30KG2 Type J es with Standard Markings 3 Application Color Marking Color Marking Red lank E30KJ0 Green OFF E30KJ22 MOTOR RUN E30KJ ON E30KJ24 ON E30KJ2 Amber lank E30KJ30 POWER ON E30KJ3 lue lank E30KJ40 MOTOR STOP E30KJ4 Clear lank E30KJ50 Green lank E30KJ20 White lank E30KJ60 MOTOR STOP E30KJ2 MOTOR RUN E30KJ23 Type K es with Standard Markings (Sold in Pairs Only) 4 Application Notes Color Marking Left Hand Right Hand Left Hand Right Hand Red Red ON ON E30KK2 Green ON OFF E30KK3 Green OFF OFF E30KK22 Red OFF ON E30KK23 For lenses with special markings or with standard markings but in a different color, refer to instructions on Pages V7-T-76 to V7-T-7. 2 Use with operators E30CA thru CM and A thru M, legend characters 3/6 in (4. mm) high except MOTOR RUN, POWER ON and MOTOR STOP are / in (3.2 mm) high. 3 Use with operators E30EA thru EM, FA thru FM and GA thru GM, legend characters / in (3.2 mm) high. 4 Use with operators E30JA thru JW, legend characters / in (3.2 mm) high V7-T-72 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March 204

10 Pushbuttons and Indicating Lights.7 Type K es Type K es lank (Sold in Pairs Only) Color Color Left Hand Right Hand Left Hand Right Hand Red Red E30KK0 lue Red E30KK4 Green E30KK Green E30KK42 Amber E30KK7 Amber E30KK43 lue E30KK4 lue E30KK40 Clear E30KK5 Clear E30KK45 White E30KK6 White E30KK46 Green Red E30KK2 Clear Red E30KK5 Green E30KK20 Green E30KK52 Amber E30KK27 Amber E30KK53 lue E30KK24 lue E30KK54 Clear E30KK25 Clear E30KK50 White E30KK26 White E30KK56 Amber Red E30KK3 White Red E30KK6 Green E30KK32 Green E30KK62 Amber E30KK30 Amber E30KK63 lue E30KK34 lue E30KK64 Clear E30KK35 Clear E30KK65 White E30KK36 White E30KK60 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March V7-T-73

11 .7 Pushbuttons and Indicating Lights Contact locks Standard Contact locks Molded, phenolic construction. Enclosed silver contacts with reliability nibs that improve the reliability of switching performance under dry circuit, corrosive atmosphere and fine dust conditions. For more extreme conditions, the logic level contact blocks described below are recommended. Logic Level Contact locks Feature palladium contacts. Palladium, which is more inert than gold, is well suited for voltages and currents approaching zero. When mounted in an enclosure rated for highly corrosive environments, logic level contact blocks can be used where exposure to chemicals may cause failure to other types of materials. Mounting Limitations See the contact block mounting limitations for Type E30 pushbutton and combination pushbutton and light operators on this page. Mounting positions thru indicate single depth contact blocks. Each of these positions can represent either a single circuit 600 volt block or a two-circuit 20 volt block. The two-circuit 600 volt block requires two of the numbered positions shown. Contact lock Type 2 Single Circuit, Screw Terminals Two Circuit, Screw Terminals Two Circuit, Quick Connect Terminals 20 Vac Only Two Circuit Contact lock Selection Circuit Special Contact Operation NO-NC Overlapping Notes Mounting Positions Except operator E30A, AJ or AK which will accommodate contact blocks, 2, 5 and 6 only. (See Mounting Positions above.) 2 Individually boxed contact blocks master packed 0 per carton. 3 Supplied with non-stacking screws. Limited to 2 contact blocks mounted in positions and 5. 4 o not use with maintained operators. 5 Contacts must be same polarity. Lower Contact lock Stack Operating Plunger of Operator Upper Contact lock Stack Operating Plunger Lower Contact lock Stack Upper Contact lock Stack Contact lock Mounting Positions Contact locks Can e Mounted in Positions Listed elow Upper Stack Lower Stack E30AA thru E30AM E30A thru E30CM None None E30A thru E30M None E30EA thru E30GM E30JA thru E30JM Pressure Terminals Quick Connect Terminals 3 Standard Logic Level Standard NO 600 Vac, 250 Vdc Single Circuit E30KLA E30KLAE E30KL NC E30KLA2 E30KLAE2 E30KL2 NO-NC 600 Vac, 250 Vdc Two Circuit E30KLA3 E30KLAE3 E30KL3 2NO E30KLA4 E30KLAE4 E30KL4 2NC E30KLA5 E30KLAE5 E30KL5 2NO (One early closing) 2NC (One late opening) NO-NC E30KLA6 4 E30KL6 4 E30KLA7 4 E30KL7 4 E30KLA E30KL 20 Vac Only Two Circuit E30KLA 5 E30KL 5 V7-T-74 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March 204

12 Pushbuttons and Indicating Lights.7 Accessories E30KR_ E30KT_ Half Shroud E30KR3_ E30KR30 E30KT_ E30KT3 E30KT_ E30KV E22CW E30KV2 Full Shroud Accessories escription Color/Type Collar Snap on mounting for assembly in the field. Permits lack E30KR color coding of operator heads. Size: -/32 x -/32 x /6 in. Red E30KR2 Green E30KR3 Yellow E30KR4 White E30KR5 Gray E30KR6 Orange E30KR lue E30KR rown E30KR0 Shroud Similar to collar above except for extension above the face of button to prevent accidental actuation of button. Half shroud with an extension on only half the collar may be positioned to protect top or bottom button. Guard Two collars deep, removable slide prevents accidental operation. White slide can be marked with grease pencil. Terminal lock 2 terminals, each will accommodate 2-wire terminations. Padlock Attachment for locking single button and bottom button of multi-function operators in the depressed position. Locks NC contacts open or early closing NO contacts closed. Cannot be used in conjunction with collar, shroud or boot. Transparent oot Guards against ingress of foreign material and freezing rain. Note: If this boot is used in conjunction with operator types A or AE, an extended type button must be used in the top position and a short button in the lower position. Square Hole Plug Gray enameled Stainless steel and Removal Tool Will not fit Cat. No. E30 light units listed on Page V7-T-67. Octagonal Wrench for mounting operators to panel. utton and Removal Tool Full shroud (gray) Half shroud (gray) Red with white slide Red with clear slide Short button Extended button E30KT6 E30KT7 E30KR3 E30KR32 E30KR30 E30KT E30KT2 E30KT3 E30KT4 E30KT5 E30KV E22CW E30KV2 Note Color coordinating collars, padlock attachments or legend plates cannot be used with operators equipped with a transparent boot. Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March V7-T-75

13 .7 Pushbuttons and Indicating Lights Options Markings and Legend Plates uttons or es with Non- Standard Horizontal Markings Markings not listed as Standard Markings below are considered non-standard. If more than one marking is required on a button or lens, order non-standard markings. Legend Locations Type A buttons and Type F lenses / in (3 mm) 3/6 in (5 mm) Standard Markings AUTO CLOSE OWN C 6 C 6 G Type buttons and Type G lenses / in (3 mm) Type C buttons / in (3 mm) Type buttons / in (3 mm) F EMERG. STOP FAST FORWAR 5 5 HAN HIGH IN 5 5 Ordering Instructions Specify catalog number of blank button or lens of desired color, plus suffix STAMP for non-standard or ST for standard markings in order notes. See Pages V7-T-6 to V7-T-73. Specify size, legend desired and location in order notes by alphas as shown in example. o not exceed maximum number of legend characters per line. A C E J H INCH JOG JOG FOR. JOG REV. LOW LOWER 6 G K F K MAN. OFF ON Ordering Example Green Type button to be marked with non-standard legend ALL ELEVATORS OWN. Catalog No.: E30K300STAMP Letter Size: / in Pos. A ALL Pos. C ELEVATORS Pos. F OWN 4 A 3/6 in 5 6 C (5 mm) 6 C 4 E 5 3/6 in (5 mm) OPEN OUT RAISE E J M E J K RESET REVERSE RUN 4 E 4 A 4 C 4 SLOW START STOP 4 F 4 How to Use the Legend Location Figure No. of Characters per Line uttons es TEST UP MOTOR RUN Line Position 7 7 A C E 3/6 in 7 A (5 mm) C C 7 F Type K buttons / in (3 mm) Type E buttons and Type J lenses / in 3/6 in (3 mm) 7 A (5 mm) 7 C A G K N 3/6 in (5 mm) Type F lens only 4 A C F J L MOTOR STOP POWER ON REAY E 4 V7-T-76 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March 204

14 Pushbuttons and Indicating Lights.7 Legend Arrangements and Legend Locations Legend plates E30KM or KM Legend plates E30KM3 or KM3 Legend plates E30KM4 or KM4 Legend Plates E30KN76 or KN76 L I N E A A C C LINE E F F L I N E C A Legend plates E30KN76 or KN76 / in character size only with a maximum of six characters. Legend plates E30KM5 or KM5 Legend plates E30KM2 or KM2 Legend plates E30KM6 or KM6 Maximum Number and Size of Permissible Legend Characters of Custom Stamped Legend Plates H F F Size and Maximum Number of Characters Per Line One Span Two Span Three Span K M M A C G H G J K L M F M Type No.of Lines 3/32 in (2.5 mm) / in (3 mm) 3/6 in (5 mm) 3/32 in (2.5 mm) / in (3 mm) 3/6 in (5 mm) 3/32 in (2.5 mm) / in (3 mm) 3/6 in (5 mm) Standard Large Characters available for non-standard markings 3/32 in (2.5 mm) / in (3 mm) 3/6 in (5 mm) A C E F G H I J K L M N O P Q R S T U V W X Y Z. /, A E F L M Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March V7-T-77

15 .7 Pushbuttons and Indicating Lights uttons or es with Non-Standard Vertical Markings Ordering Instructions Specify catalog number of blank button or lens of desired color, selected from listings on Pages V7-T-6 to V7-T-73. Specify size, legend desired, location and state vertically marked in order notes. Note: Specify either / or 3/6 in (3.2 or 4. mm) character height. o not exceed maximum number of characters as outlined in table below. Ordering Example: Green Type K button to be marked with RUN ON. Catalog No.: E30KK20STAMP Letter Size: 3/6 in (4. mm) Vertically Marked Pos. RUN Pos. E ON Maximum Number of Characters Legend Plates Legend plates for Type E30 compact pushbutton and indicating light operators hook directly onto the operator and are clamped in place when the operator locking nut behind the panel is secured. Two and three span plates are designed for use where two or more operators are mounted adjacent to each other on minimum horizontal mounting centers. These legend plates mount in the same manner as single span units. Maximum Number of Characters escription Type / in (3.2 mm) 3/6 in (4. mm) uttons A C E 7 5 es F 7 5 G 7 5 J 7 5 K 3 2 When Ordering Legend Plates with Markings Catalog number of blank legend plate Insert the following in order notes: Legends required Size of characters 3/32, /, 3/6 in (2.4, 3.2, 4. mm) Positions of legends on one line standard and two line large legend plates by alphas as shown in sketches on following page. Standard One Span Large One Span Ordering Example: Three span legend plate to be marked MASTER CONTROL, STATION A and STATION. Catalog No.: E30KM3STAMP Letter Size: / in (3.2 mm) Pos. C MASTER CONTROL Pos. STATION A Pos. F STATION lank Legend Plates and Legend Plates with Markings Type lack Standard Large One Span E30KM E30KM4 V7-T-7 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March 204

16 Pushbuttons and Indicating Lights.7 Replacement Parts Replacement Light Units for E30 Components Voltage AC and C Full Voltage Type Replacement s for E30 Illuminated Operators Replacement s Incandescent and LE Note Part Numbers Receptacles without s Single Indicating Light ual Indicating Light E30 blue LE bulbs may not provide sufficient intensity for some applications. Single Light Single Pushbutton Single Light ual Pushbutton ual Light ual Pushbutton 6V A A A A V A A A A /24V A A A A V A A A A V A A A V A A A A V A A A A Transformer Type 20V A A A A A 20V A A A A A 240V A A A A A 30V A A A A A 40V A A A A A 600V A A A A A escription and Part Numbers Related Parts Inner lens Retaining nut Gasket Locking ring Mfg. Type Voltage ase Style Application Part Number 6PS 6V T2 slide E30 transformer and full voltage PS 2V T2 slide E30 full voltage PS 24V T2 slide E30 full voltage PS 2V T2 slide E30 full voltage PS 4V T2 slide E30 full voltage PS 60V T2 slide E30 full voltage PS 20V T2 slide E30 full voltage 2-02 #25 6.3V T3-/4 wedge E30 single transformer 2-4 Voltage Incandescent s Manufacturer s Part Number ase Style Eaton s Part Number LE s Eaton s Part Number Red Green Yellow lue 6 6PS T2 slide PS T2 slide PS T2 slide PS T2 slide PS T2 slide PS T2 slide Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March V7-T-7

17 .7 Pushbuttons and Indicating Lights Technical ata and Specifications Operator Specifications escription Specification Climate Conditions Operating 20 to 50 F ( 2 to 65 C) Terminals Light units Terminals are saddle clamp type for 2 stranded or solid wires up to 2 AWG (4.0 mm 2 ) Torque 7 lb-in (0. Nm) Contact block Terminals are saddle clamp type for 2 stranded or solid wires up to 2 AWG (4.0 mm 2 ) Torque 7 lb-in (0. Nm) Materials Operator Zinc base die casting with a copper-nickel-chrome plated finish Withstands the 200 hr. salt spray test in accordance with MIL Spec. QQ-M-5A and NEMA 4X testing. Internal parts Including shafts, washers and springs, are made of stainless steel uttons and lenses Colorfast, wear resistant, molded acetal resin Contact blocks Made of molded, heat resistant, mineral filled phenolic Contact block plungers are molded of nylon filled phenolic Contacts are silver Reliability nibs These nibs combine a scrubbing action with high pressure density when the contacts are closed They push through particles and films found on contact surfaces in industrial environments Reliability nibs self-adjust to the application dry circuit, normal or heavy-duty Reliability Nibs Electrical Ratings Contact locks Meet or Exceed NEMA Contact Rating esignation A600 and P300 Vac A600 Vdc P300 escription 20V 240V 40V 600V 24/2V 25V 250V Make and emergency interrupting capacity (Amps) Normal load break (Amps) Continuous current (Amps) UL A600/P300 nominal connect 0A NO, NC, 2NO, 2NC, NO-NC, early make, late break and overlapping configurations Mechanical positive drive operation on NC contacts Palladium alloy contact for logic level or highly corrosive environments Maximum Ratings for Logic Level and Hostile Atmosphere Application escription Specification Maximum amperes 0.5A Maximum volts 20 Vac/Vdc Note ry Circuit Medium uty Logic level contact blocks are UL A600/P500 rated per table above. Heavy-uty Light Unit escription ulbs Average Life Transformer type Resistor/direct voltage type LE Specification 20,000 hrs. 2,500 hrs. min. at rated voltage 60,000 to 00,000 hrs. V7-T-0 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March 204

18 Pushbuttons and Indicating Lights.7 imensions Approximate imensions in Inches (mm) Pushbutton Operators. (47.).75 (44.5) Combination Pushbutton and Indicating Light Operators Padlocking Attachment and Half Shroud E30KT7 Legend Plates 0.53 (3.5).3 (2.7).47 (37.3) 0.63 (6) Square Std. utton 0.7 (.) Ext. utton. (47.).75 (44.5).47 (37.3) Square.44 (36.6) 0. (2.) Max. 0.7 (.) 0.3 (.) Large.3 (2.7) 0.75 (.) 0.53 (3.5) 0.4 (2.3).3 (2.7) 0.3 (7.) ia. Hole 0. (20.6).72 (43.7) Panel 0.06 (.5) Min (6.4) Max. 0. (20.6) 0. (22.4) 2 Circ. Cont. locks.72 (43.7) 4.6 (.) Three Span 3.06 (77.7) Two Span.44 (36.6) One Span Standard.72 (43.7) Plunger Extends to 0.25 (6.4) (22.4) (22.4) Circ. Cont. locks Full Voltage Types F, M and X Transformer Types A L 0. (22.4) 0. (22.4) Panel Plunger Extends 0.06 (.5) Min. to 0.25 (6.4) on 0.25 (6.4) Max. Contact locks 0.0 (.) 0.05 (.3) 0.5 (2.7) 0.6 (7.5).5 (40.4) 0.56 (4.2) 0.02 (0.5) Combination Pushbutton and Indicating Light Operators. (47.) Indicating Light Operators. (47.) rilling imensions Minimum Spacing a (57) Notes.75 (44.5).47 (37.3) Square.75 (44.5).47 (37.3) Square.63 a (4.3) rill.4 (3.5).3 (2.7).3 (2.7) 0.53 (3.5) 0.53 (3.5) ø.20 (30.5) 0.6 (5) 0.4 (2.3) 0.4 (2.3) 0. (20.6) 0. (20.6) 0. (22.4).72 (43.7) Panel 0.06 (.5) Min (6.4) Max. 0. (22.4).72 (43.7) Panel 0.06 (.5) Min (6.4) Max. Operator Types E30EA E30GM Operator Types E30JA E30JW Transformer or Full Voltage Light Element Plungers Extended to 0.25 (6.4) Operator Types E30A E30M Operator Types E30CA E30CM imensions shown allow adequate space for the addition of one or two high legend plates and color coordinating collars. 2 Locating nib hole or notch is 0.36 in (3.5 mm) drill. Alternate to drilling mounting holes use Greenlee Tool Co. punch (No. 730-S) to punch the hole and (No. 730-K) to punch the notch. Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA00000E March V7-T-

1.3. Pushbuttons and Indicating Lights.

1.3. Pushbuttons and Indicating Lights. .3 Pushbuttons and Indicating Lights Pushbutton Control Stations Contents Page Features.............................. V7-T-5 Product Selection M22 Assembled Control Stations........ V7-T-6 Commercial Control

More information

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below. Bulletin H Product verview/specifications Bulletin H/ Hazardous locations push buttons and stations Classes I, II & III Divisions & / in. - NPSM barrel Type & Explosion-proof operators Table of Contents

More information

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35 Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only) 1-,, 3-, 4- Toggle Switches (Bul. 800T only) 800T T2 H2 E E X X a b c d e f g Right Left Right Left Blank C T1 T2 T3 T4 a Finger-Safe Guards Description No guards Guards on terminals b Operator Type Description

More information

Round Indicator Lights Mounting Hole Page

Round Indicator Lights Mounting Hole Page PRODUCT SERIES Round Indicator Lights Page 8, &. 9. &..7 - NEMA -R.7 8 & 9. 7. 8. 9 7. 8. - NEMA -R.9.9 Indicator Lights.7,.. 7. Rectangular Indicator Lights Panel Cutout. x.. x. 7 & 7. x.8 8. x. 9 & 7.

More information

PSOL. Remove mounting screws. Remove ears. Add 6" leads PSOL = #12 AWG solid PSTR = #12 AWG stranded

PSOL. Remove mounting screws. Remove ears. Add 6 leads PSOL = #12 AWG solid PSTR = #12 AWG stranded Switch Options Work Smarter Not Harder Arrow Hart custom configured wiring devices can match any of your complex industrial or commercial job needs, simplifying your project and maximizing your bottom

More information

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent ulletin 800T 30.5 mm Push uttons 2-Position Knob/Lever Type Selector Switch Units, Illuminated Operator Position Operator Type Standard Knob Knob Lever Type Lamp Volts olor M = Maintained S = Spring Return

More information

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton Edition 10/2016 HMI Components 41 Series Characteristics The rectangular design of the Series 41 (18 x 24 mm) makes it especially suited: Raised design PCB (with adaptor) Functions The Series 41 incorporates

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Actuators Series 8602/3

Actuators Series 8602/3 > Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons

More information

AMP Power Lock Connectors

AMP Power Lock Connectors Product Facts High current handling capability: 31 or 53 amperes maximum depending on application (reference product specs) Modular housings for multiple connector applications Assortment of mounting accessories

More information

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number Non-Illuminated Momentary Pushbutton Units Flush Button Extended Button Mushroom Button Jumbo Mushroom Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators Contact Type Button

More information

SB 50 Connectors - up to 120 amps

SB 50 Connectors - up to 120 amps Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP s two pole SB connectors set the standard for DC power distribution and battery connections. connectors feature a one

More information

Sensor Accessories Retroreflectors and Retroreflective Tape 8-2

Sensor Accessories Retroreflectors and Retroreflective Tape 8-2 - Retroreflectors and Retroreflective Tape PG.05E.17.T.E Retroreflectors Contents Overview.................... - Model Selection............... -3 Dimensions.................. -3 High Quality Retroreflectors

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Micro-Change. Cordset Family

Micro-Change. Cordset Family Side Tab Cordset Family Small Space? Big Solution. When space and time are in short supply, look no further than Brad Harrison brand for the best, ready-made m connector solutions. For fast, compact migration

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

Complete units: Push-buttons ø 22mm

Complete units: Push-buttons ø 22mm Complete units: Push-buttons ø 22mm FLUSH SPRING RETURN - NON-ILLUMINATED Chrome Bezel Part Number Technical Info (p. 103) Black Bezel Part Number 11 Ø 29.9 20.1 19.6 With single position clip Red NC L21AA01-1E01

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Control Stations ø 22

Control Stations ø 22 Control Stations ø 22 CONTROL STATIONS - NON-ILLUMINATED Technical Info (p. 103) MUSHROOM HEAD Ø 40 - MAINTAINED Push-turn to reset Part Number M16/20 47.9 25.7 Ø 40 Red NC EMERGENCY STOP LBX10510 Red

More information

40.4. Control Relays and Timers. Contents. D3PR/D3PF Series. General Purpose Plug-In Relays. Features. Standards and Certifications

40.4. Control Relays and Timers. Contents. D3PR/D3PF Series. General Purpose Plug-In Relays. Features. Standards and Certifications Control Relays and Timers. D Series Relay Contents Description Page DPR/DPF Series................................ DPR/DPF Series................................ DPR/DPF Series Catalog Number Selection........................

More information

SPEC Pak. Sealed Power For Environmental Connections. Anderson Power Products. Marine Wind Power Lighting Transportation Pumps Ground Support

SPEC Pak. Sealed Power For Environmental Connections. Anderson Power Products. Marine Wind Power Lighting Transportation Pumps Ground Support SPEC Pak Sealed Power For Environmental Connections Marine Wind Power Lighting Transportation Pumps Ground Support Machine Tool Industrial Automation Motor Solar Power Harsh Environments Anderson Power

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10

More information

Complete units: Mushroom heads ø 22mm

Complete units: Mushroom heads ø 22mm Complete units: Mushroom heads ø 22mm MAINTAINED - NON-ILLUMINATED Ø 40 MUSHROOM Push-pull to reset Technical Info (p. 103) Black Bezel Part Number 34.2 Ø 40 Red NC L22DD01-3E01 Red 2 NC L22DD01-3E02 Red

More information

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays .6 Control Relays and Timers Product Overview Catalog Number Selection D9, D96 and D99 Series Description D9 = Hockey puck D96 = Compact D99 = DIN rail Contents D 9 2 5 A M D 2 Output Voltage 1 = 2 60

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm SPRING RETURN - NON-ILLUMINATED Technical Info (p. 103) FLUSH-FLUSH Twin touch Chrome Bezel Part Number Black Bezel Part Number 12.3 11 53.9 29.9 With International Symbols Green

More information

Complete units: Selector switches ø 22mm

Complete units: Selector switches ø 22mm Complete units: Selector switches ø 22mm SELECTOR SWITCHES - NON-ILLUMINATED Technical Info (p. 13) WITH KNOB 2 and 3 positions Chrome Bezel Part Number Black Bezel Part Number Ø 29.9 Maintained positions

More information

SBS Connectors - up to 110 amps

SBS Connectors - up to 110 amps SBS Connectors - up to 11 amps SBS 75G SBS 75X Wire to Wire The patented SBS connector family is designed to provide high power in a compact ergonomic housing with protection against accidental contact

More information

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1 F o r P r o f e Klein s line of wrenches are forged from the finest steel and are designed to deliver great strength, and long working life. Regardless of the job type, Klein has a wrench that will help

More information

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3. 6-4 Freedom Pump Panels Circuit reaker R Enclosure / -Phase Magnetic / Interchangeable eater OLR These ECN Irrigation Pump Controllers feature the Cutler-ammer Freedom Series starters. They have a AND/OFF/AUTO

More information

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series Heavy Duty Door Clamping Junction Box Padlock Kit www.hammfg.com Quick Release Clamp New note style replacement hardware for use on 1418N4, 1418N4SS, 1447SN4, and 1447SN4SS Hammond enclosures. Formed heavy

More information

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2 30.5 mm Stations Hermetically Sealed for Division 2/Zone 2 10 Bulletin 800R Hazardous Location Stations Classes I and II Division 2/Zone 2 30.5 mm Mounting Hole Types4/13and4/4X/13 0 TABLE OF CONTENTS

More information

HANDLEY CATHODIC TEST STATIONS

HANDLEY CATHODIC TEST STATIONS Rev. 07/05 HANDLEY CATHODIC TEST STATIONS 2 Inch Cathodic Test Stations 4 Inch Cathodic Test Stations 2 Inch Monitoring Stations 2" Test Station Parts and Accessories, 2" Monitoring Station Parts and Accessories,

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm ONE-PIECE PILOT LIGHTS Technical Info (p. 103) SUPPLIED WITHOUT BULB Part Number L20SA40 14.3 44.1 Ø 29.8 Ø 20.2 Ø 22 Ø 29.5 1 to 6 6 Ribbed Lens Clear Smooth Lens With text or symbol

More information

KRPA, KRP, KA, KR series

KRPA, KRP, KA, KR series Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting

More information

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification. Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.

More information

SBS Connectors - up to 110 amps

SBS Connectors - up to 110 amps Connectors - up to 1 amps NEW 75G 75X Wire to Wire The patented connector family is designed to provide high power in a compact ergonomic housing with protection against accidental contact with live circuits.

More information

Local control stations for Zone 1 and Zone 21. Features. Description

Local control stations for Zone 1 and Zone 21. Features. Description Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning

More information

H8508 Impact Wrench SERVICE MANUAL. Model (Serial Code FWN) Model (Serial Code FWP)

H8508 Impact Wrench SERVICE MANUAL. Model (Serial Code FWN) Model (Serial Code FWP) SERVICE MANUAL H8508 Impact Wrench Model 48755 (Serial Code FWN) Model 48760 (Serial Code FWP) Read and understand all of the instructions and safety information in this manual before operating or servicing

More information

Powerpole Connectors - PP120: up to 240 Amps

Powerpole Connectors - PP120: up to 240 Amps Powerpole Connectors - : up to 240 Amps series Powerpole housings are designed to accommodate up to 1/0 ( mm²) wires and handle high currents up to 240 amps. Reducing bushings allow to accept down to #8

More information

Position switches FM series

Position switches FM series B Position switches FM series Selection diagram 0 08 0 A A 0 A 0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket 69 stainless steel round rod square rod fiber

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

A W - A 2A R - 24D - 1

A W - A 2A R - 24D - 1 Knob-type Selector Switch A165S/W Mounting Aperture of 16 mm Modular construction Oil-resistant IP65 models UL and cul approved. Conforms to EN60947-5-1, IEC947-5-1 Short mounting depth, less than 28.5

More information

Bulletin 800FC 22.5 mm Configured Pendant Stations Product Overview. Position 1... Position 9

Bulletin 800FC 22.5 mm Configured Pendant Stations Product Overview. Position 1... Position 9 Product Overview Configured Pendant Stations -, -, -, and -button configurations -, -, and -speed push buttons IP, NEMA Type /X/ Finger-safe contact blocks uttons are flush-mounted with the enclosure to

More information

LR Position Switches TECHNICAL DATASHEET

LR Position Switches TECHNICAL DATASHEET TECHNICA DATASHEET Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 69 contact blocks available actuators available M assembled connector versions Silver

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Factory Assistance: Phone: Fax: Page 1

Factory Assistance: Phone: Fax: Page 1 CABLE RUNWAY ACCESSORIES Radius Drop / Stringer Drop Provides 3 bend radius Radius drop fits 6, 12 and 18 runway made from 1-1/2 x 3/8 tubing Steel construction Includes (3) cable spools, (1) bolt, (1)

More information

3.4. Control Relays and Timers. Contents Description. D2RR/D2RF Series. General Purpose Plug-In Relays. Features

3.4. Control Relays and Timers. Contents Description. D2RR/D2RF Series. General Purpose Plug-In Relays. Features Control Relays and Timers. D Series Relay Contents Description DRR/DRF Series......................... DRR/DRF Series Catalog Number Selection................ Product Selection....................... Accessories............................

More information

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) THREE-PHASE SUBSURFACE UNDERGROUND COMMERCIAL DISTRIBUTION (UCD) TRANSFORMER NOTE: This "Guide" summarizes the opinions, recommendations, and practices

More information

Available in high-capacity. and assembled by hand for smooth operation. Durable chrome-plated finish. Heat-treated for long life.

Available in high-capacity. and assembled by hand for smooth operation. Durable chrome-plated finish. Heat-treated for long life. Klein s line of wrenches are forged from the finest steel and are designed to deliver great strength and long working life. Regardless of the job type, Klein has a wrench that will help the professional

More information

Series 300. Miniature Rocker & Paddle Switches

Series 300. Miniature Rocker & Paddle Switches SPECIFICATIS: CTACT RATING: Refer to "Contact Material Options" for more info. ELECTRICAL LIFE: 0,000 make-and-break cycles at full load. CTACT RESISTANCE: 0m max. inital @ -VDC. 00mA for both silver and

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Wide Selection of High Performance Small DC Sensors Offers Longer Sensing Distances Fast 0. msec response time for high-speed sensing Extended sensing distances up

More information

GENERAL PURPOSE RELAYS

GENERAL PURPOSE RELAYS CONTROL LOGIC GENERAL PURPOSE RELAYS GR c3controls offers a full line of General Purpose Relays ( plug-in relays), perfect for your control logic applications. Quick and economical to install, our relays

More information

Creating Electrical Designs

Creating Electrical Designs C h a p t e r 2 Creating Electrical Designs In this chapter, we will learn the following to World Class standards: Understanding Control and Power Circuits Drawing the Control Circuit Selecting the Pushbutton

More information

Position switches FR series

Position switches FR series B Position switches FR series Selection diagram 0 A 0 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

Sorenson Lighted Controls

Sorenson Lighted Controls Sorenson Lighted Controls Illuminating Innovation 9 INDICATOR CATALOG New Products Located on Pages - Sorenson Lighted Controls Illuminating Innovation ORDER TERMS & CONDITIONS Minimum OEM Order Value:

More information

FM series position switches

FM series position switches FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass

More information

Thread protection accessories are installed at the MODIX production factory and delivered with couplers.

Thread protection accessories are installed at the MODIX production factory and delivered with couplers. Installation of MODIX Rebar Coupler Identification of the product The type of MODIX Rebar Coupler can be identified by the marking on the product. Size of the Coupler can be identified also according to

More information

A. Product Data: For each electrical identification product indicated.

A. Product Data: For each electrical identification product indicated. SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Power Connectors for Industrial and Commercial Applications

Power Connectors for Industrial and Commercial Applications Table of Contents AMP, AMPINNERGY, AMPOWER, AMP-O-LECTRIC, AMP-TAPETRONIC, DIAMOND GRIP, ELCON, RAYCHEM, SOLISTRAND, and TYCO are trademarks. AMP Power Series Connectors Selection Guide and Overview 3,4

More information

Ledex Low Profile Linear Solenoids

Ledex Low Profile Linear Solenoids Ledex Low Profile Linear Solenoids 6 5% Duty 8W 5% Duty W % Duty W 7 8 9 Ledex Low Profile Solenoids Linear actuation Space-saving, low-profile configuration Ideal for high force, short stroke applications

More information

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays

3.4. Control Relays and Timers. Contents Description D5RR/D5RF Series... D7PR/D7PF Series. General Purpose Plug-In Relays .4 D7 Series Relay Contents Description D1RR/D1RF Series......................... D2RR/D2RF Series......................... DRR/DRF Series......................... D4 Series................................

More information

The DeltaGrip System. Safety and Operating Instructions. Trigger. Air Supply Connection. Handle Assembly. Air Line Assembly.

The DeltaGrip System. Safety and Operating Instructions. Trigger. Air Supply Connection. Handle Assembly. Air Line Assembly. The DeltaGrip System Safety and Operating Instructions Trigger Air Supply Connection Handle Assembly Air Line Assembly Punch Die Pneumatic Diaphragm Assembly Shackle, Pin & Jam Nut Jaw Frame Shoulder Screw

More information

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth STRENGTH Diamond serrated jaws provide a firm grip PLIERS AND SNIPS Locking Pliers Slip Joint Pliers Electrician s Pliers

More information

Ledex Low Profile Linear Solenoids

Ledex Low Profile Linear Solenoids Ledex Low Profile Linear Solenoids 8. (55.9) 6. (66.9). (77.9). (89.) % Duty Cycle W 5% Duty Cycle 8W 5% Duty Cycle 6W % Duty Cycle W Ledex Low Profile Solenoids Linear actuation Space-saving, low-profile

More information

Swivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types.

Swivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types. RIGGING ACCESSORIES Color coded to distinguish between UNC (Red) and Metric (Silver) thread types. Available in UNC and Metric thread sizes. UNC threads available in sizes from 800 pounds to 100,000 pounds,

More information

Separate units: Blocks

Separate units: Blocks Separate units: Blocks LED BLOCKS Technical Info (p. 103) SCREW TERMINALS Part Number 3.8 LED 19.7 20.1 X1 X2 33EARL 9.9 19.7 21.5 18.2 12/24 V White Red Green Blue Yellow 33EAWL 33EARL 33EAGL 33EABL 33EAYL

More information

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz). 121 Series Coaxial Snap On & Screw On Types / 50 Ohm & 75 Ohm These 50 and 75 Ohm coaxial connectors are easily inserted into your printed circuit board using an insertion tool. Solder is eliminated and

More information

TOGGLE SWITCHES IP67 A 9 SERIES 1B AGENCY APPROVALS SPECIFICATIONS

TOGGLE SWITCHES IP67 A 9 SERIES 1B AGENCY APPROVALS SPECIFICATIONS AGENCY APPROVALS SPECIFICATIONS Sealed miniature toggle switches C IP67 File N E195524 File N E195524 In conformity with: EN 60529: 1991 IEC 529: 1989 CHARACTERISTICS Contact Rating: S (silver) - 5A with

More information

SEALED, ILLUMINATED ROCKER SWITCHES

SEALED, ILLUMINATED ROCKER SWITCHES K/K LOW OST, ROKER FOR WET & DUSTY ENVIRONMENTS The K series rockers are rugged, high performance sealed switches designed for use under severe conditions found in marine, appliance, heavy equipment and

More information

Quality Commitment # #

Quality Commitment # # Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing

More information

CPT SS-MI TABLE OF CONTENTS. Pass Thru Brochure Pass Thru Drawing. Pgs. 2-3 Pg. 4

CPT SS-MI TABLE OF CONTENTS. Pass Thru Brochure Pass Thru Drawing. Pgs. 2-3 Pg. 4 CPT3648-54-SS-MI TABLE OF CONTENTS 1) 2) 3) Pass Thru Brochure Pass Thru Drawing Installation & Parts List Latch Info Spring Info Hinge Info Spring Info Halco Warranty Pgs. 2-3 Pg. 4 Pg. 6 Pgs. 7-8 Pg.

More information

Standard Product. Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories

Standard Product. Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories Spec-00466 F763.422.2661 763.422.2588 Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories 19-in. Mini-Rack

More information

SMT TR series. Surface mount tiny washable rocker switches. Distinctive features and specifications.

SMT TR series. Surface mount tiny washable rocker switches. Distinctive features and specifications. SMT TR series Surface mount tiny washable rocker switches istinctive features and specifications Entirely designed for surface mount Tape and reel packaging Reflow solderable High temperature plastic materials

More information

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to ORDER LENGTH codes B through F; code A has 22 adjustment. UL / FM MUELLER Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also, the Indicator

More information

General Specifications

General Specifications Series M Miniature Rockers Touch Tilt Rockers Toggles Slides Rotaries Programmable Illuminated P Pushbuttons Supplement Accessories Indicators Tactiles Keylocks General Specifications Electrical Capacity

More information

WESTERN WIRE PRODUCTS

WESTERN WIRE PRODUCTS WESTERN WIRE PRODUCTS Celebra ng 100 years of Quality and Service 1914 2014 Thanks to our dedicated employees and customers we are celebra ng 100 years of being in business and we look forward to servicing

More information

onlinecomponents.com

onlinecomponents.com Introducing T&B Marrette Wire Connectors In 1914, William Marr invented the world s first pressure type wire connector. Since then, Marrette connectors have become synonymous with best quality wire connector.

More information

TNC SERIES General... 4 Interface... 5 Characteristics...6-7

TNC SERIES General... 4 Interface... 5 Characteristics...6-7 CONTENTS PAGE TNC SERIES General... 4 Interface... 5 Characteristics...6-7 TNC 50 Ω SERIES Plugs...8-9 Jacks...0- Jacks and receptacles... Receptacles...-4 Adapters... 5 Caps... 6 TNC 75 Ω SERIES Plugs...

More information

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET HIGH EDGE 2 1/4"(57mm) 03079400070 INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET IMPORTANT: THIS LOCK IS NON-HANDED. LOCK IS FACTORY PACKED PREADJUSTED FOR 1³ ₄" (45mm)

More information

B3199R - Ceiling Flange B3199RCT - Ceiling Flange Dura-Copper Coated. TOLCO Fig All Steel Ceiling Plate. 216 Eaton

B3199R - Ceiling Flange B3199RCT - Ceiling Flange Dura-Copper Coated. TOLCO Fig All Steel Ceiling Plate. 216 Eaton ttachments 3199R - eiling Flange 3199RT - eiling Flange ura-opper oated Size Range: 3 /8"-16 & 1 /2"-13 rod Material: Malleable Iron (Stainless Steel Type 304 available) Standard 3199RT is UR-OPPER coated

More information

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Baymaster HL LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval Redwood City Electric, Inc. TRANSMITTAL LETTER To: Transworld Construction, Inc. 1178 Folsom Street San Francisco, CA 94103 Date: 05/31/12 Job #: 9340 Regarding: SFO DATA CENTER Attn: Rob Acero We are

More information

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 www.icc-rsf.com INSTALLATION AND OPERATION INSTRUCTIONS "Model VIP" CHIMNEY TYPE: FACTORY BUILT

More information

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION MICRO SWITCH Key-Operated Safety Interlock Switch GK Series DESCRIPTION MICRO SWITCH GK Series switches are key-operated safety interlock rugged metal switches which monitor the positions of gates, guards,

More information

19-in. Mini-Rack Cabinet, Type 1

19-in. Mini-Rack Cabinet, Type 1 Spec-00466 19-in. DP FX (763) Mini-Rack 422-2588 422-2661 Cabinet, Components and Accessories Free-Stand Networking Cabinets 19-in. Mini-Rack Cabinet, Type 1 Industry Standards NEMA Type 1 EIA 310-D /

More information

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE PUSHBUTTON SWITCH / SEECTOR SWITCH / IUMINATED PUSHBUTTON SWITCH PSA, PSA TYPE FEATURES 1 3 The PSA and SPSA types are oil-proof. The enclosure rating is IP65 (water-jet-proof type), covering wide applications.

More information

TWO PIECE / PLUGGABLE CONNECTORS

TWO PIECE / PLUGGABLE CONNECTORS DESCRIPTION/APPLICATION Designed to European specifications, these two piece blocks provide interconnection between wire and PC board. Wire is terminated at the connector and the header is mounted to the

More information

DISCONNECT SWITCHES. UL Listed CSA Certified

DISCONNECT SWITCHES. UL Listed CSA Certified POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole

More information

DEUTSCH Instructional Manual for HDP-400 Power Crimper (TE CONNECTIVITY PN )

DEUTSCH Instructional Manual for HDP-400 Power Crimper (TE CONNECTIVITY PN ) ORIGINAL INSTRUCTIONS DEUTSCH Instructional Manual for HDP-400 Power Crimper (TE CONNECTIVITY PN 1606312-1) Instruction Sheet 0425-034-0000 15 JAN 18 Rev H NOTE All numerical values are in metric units

More information

T S 15KVA 1PH 240/480 Transformer

T S 15KVA 1PH 240/480 Transformer 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T2535173S 15KVA 1PH 240/480 Transformer Acme Electric Catalog Number Manufacturer Description Weight per unit Product

More information

Precision and High Reliability Thermostats Issue 3. Datasheet. Table of Contents

Precision and High Reliability Thermostats Issue 3. Datasheet. Table of Contents Precision and High Reliability Thermostats DESCRIPTION Thermostats can provide either temperature control or overtemperature protection by breaking electrical contact when a specified temperature is reached.

More information

Quarter-Turn Fasteners

Quarter-Turn Fasteners Solutions Inc. SU-2300 Line Quarter-Turn Fasteners MIL-F-5591C * Approved The SU-2300 Line fasteners are designed for aircraft use and are used on external access panels and internal equipment. They are

More information

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton Edition /204 HMI Components 8 Series Characteristics The compact 8 mm Series 8 is especially suited for: Flush design Raised design PCB (with adaptor) Functions The Series 8 incorporates the following

More information

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights Characteristics 1 Environment Protective treatment Standard version TH Ambient air temperature Storage C - 40 + 70 around the device Operation C - 25 + 70 for LED and neon bulb versions - 25 + 40 for incandescent

More information

M4 Hex Nut [ ] M4 T-Nut 20 [20-044] Appx. 1. 3mm. 20 Series profiles (1 per hole) (1 per hole) Ordering Information

M4 Hex Nut [ ] M4 T-Nut 20 [20-044] Appx. 1. 3mm. 20 Series profiles (1 per hole) (1 per hole) Ordering Information Handles & Light Duty PA 20 1 Assembly of Hinge M4x8 FHCS [24-208-4] M4 T-Nut 20 [20-044] M4 Hex Nut [24-706-4] 60 300-0 PA 20 on panel 2 Hinge positions 3-4 Clearance dimensions 5 Range of swing FOR M4

More information

Quick-Release Front Vise 05G34.01

Quick-Release Front Vise 05G34.01 Quick-Release Front Vise 05G34.01 Patent Pending Introduction A front vise is the most generally useful vise on a typical workbench. It can be used for clamping parts on edge within the jaws, for clamping

More information

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87 Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................

More information

MESA-HPX. Assembly and Installation Manual. w/appendix A for Prodelin Antenna. 901-Manual-MESA-HPX

MESA-HPX. Assembly and Installation Manual. w/appendix A for Prodelin Antenna. 901-Manual-MESA-HPX MESA-HPX Assembly and Installation Manual w/appendix A for Prodelin Antenna 901-Manual-MESA-HPX Rev 30 March 2011 2 INDEX Installation Cautions 4 Installation Pole Height Orientation of the Mount on the

More information