Pendant control stations 6

Size: px
Start display at page:

Download "Pendant control stations 6"

Transcription

1 Characteristics 6 Environment Conformity to standards IEC , EN Product certifications NEMKO. Special version: UL Listed A600-Q600, CSA A600-Q600 Protective treatment Standard version TH Ambient air temperature For operation C For storage C Vibration resistance 15 gn ( Hz) conforming to IEC Shock resistance 100 gn conforming to IEC Electric shock protection Class II conforming to IEC 536 and NF C Degree of protection IP 65 conforming to IEC 59; IK 08 conforming to EN 5010 Mechanical durability (in millions of operating cycles) Enclosure Cable entry 1 Double insulated polypropylene, coloured yellow throughout Rubber sleeve with stepped entry diameter for cable Ø 8 Ø 6 mm Contact block characteristics Rated operational characteristics ZB BEppp, XEN Gpppp, XAC Spppp XEN Tpppp Thermal current (lthe) A 10 a AC-15: A600 or Ue = 600 V, le = 1. A or Ue = 0 V, Ie = 3 A c DC-: Q600 or Ue = 600 V, le = 0.1 A or Ue = 50 V, Ie = 0.7 A a AC-15: A300 or Ue = 0 V, le = 3 A c DC-: Q300 or Ue = 50 V, le = 0.7 A conforming to IEC Appendix A Rated insulation voltage (Ui) ZB BEppp, XEN Gpppp, V 600, degree of pollution 3 XAC Spppp XEN Tpppp 00, degree of pollution 3, conforming to IEC 97-1 Rated impulse withstand voltage (U imp) kv 6, conforming to IEC 97-1 Positive operation Contact operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to IEC Section 3 N/C or N/O slow break Resistance across terminals MΩ y 5 Operating force N Operators - with contact: 10 - with contact: 8 - with additional N/O contact: with additional N/C contact: + 3 Terminal referencing Conforming to CENELEC EN 500 Short-circuit protection 10 A cartridge fuse type gg (gl) Connection mm Screw and captive cable clamp terminals. Clamping capacity: min. 1 x 0.5 mm, max., with or without cable end: x 1.5 mm or 1 x.5 mm. 6.3 mm clips (on request), please consult your Regional Sales offi ce. Rated operational power Conforming to IEC Appendix C. Utilisation categories AC-15 and DC-. Operating rate: 3600 operating cycles/hour. Load factor: 0.5. a.c. supply a 50/60 Hz d.c. o Inductive circuit supply c Power broken in W for 1 million operating cycles Millions of operating cycles 1 0,6 0, 0, Ithe 30 V 17 V...8 V Voltage V 8 10 o W , Current in A References: pages 30075/3 to 30075/6

2 References 6 Complete stations ready for use DF56553 For control of single-speed motors Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop ZB BE101 XAC A XAC A71 XAC A81 + ZB BE10 + ZB BE101 XAC A DF XAC A7 XAC A8 ZB BE latching Emergency stop Ø 30 mm operator ZA BS (1) + ZB BE10 + ZB BE101 1 ZB BE10 ZB BE XAC A7 (1) XAC A8 (1) DF5655 ZB BE101 + N/C + N/C XEN T XAC A71 (1) ZB BE10 + ZB BE101 + N/C + N/C XEN T9 1 XAC A81 (1) XAC A71 XAC A (1) To order a station with a trigger action latching Emergency stop Ø 30 mm operator (ZA BS83), replace the number 3 in the reference selected by the number. Examples: XAC A7 becomes XAC A7 and XAC A71 becomes XAC A71. page 30075/ 3

3 References (continued) 6 Complete stations ready for use DF56555 For control of single-speed motors (continued) Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop ZB BE101 XAC A ZB BE10 + ZB BE101 XAC A XAC A71 XAC A81 ZB BE latching Emergency stop Ø 0 mm + operator ZB BE10 ZA BS5 (1) + ZB BE101 1 ZB BE10 ZB BE XAC A7 (1) XAC A8 (1) ZB BE101 + N/C + N/C XEN T9 XAC A71 (1) ZB BE10 + ZB BE101 + N/C + N/C XEN T9 XAC A81 (1) XAC A7 XAC A8 XAC A71 XAC A81 6 ZB BE101 XAC A ZB BE10 + ZB BE101 XAC A ZB BE latching Emergency stop Ø 0 mm + operator ZB BE10 ZA BS5 (1) + ZB BE101 1 ZB BE10 ZB BE XAC A67 (1) 0.85 XAC A68 (1) XAC A671 XAC A681 XAC A67 XAC A68 (1) To order a station with a trigger action latching Emergency stop Ø 0 mm operator (ZA BS8), replace the number 3 in the reference selected by the number. Examples: XAC A7 becomes XAC A7 and XAC A71 becomes XAC A71. page 30075/

4 References (continued) 6 Complete stations ready for use DF56556 For control of single-speed motors (continued) Functions Number of operators 6 ZB BE latching Emergency stop Ø 0 mm operator ZA BS5 (1) + ZB BE10 + ZB BE101 Contact block(s) and scheme Reference Weight Per direction For Emergency stop + N/C + N/C XEN T9 1 + N/C + N/C XEN T XAC A671 (1) XAC A681 (1) DF XAC A671 XAC A681 I O 8 on 7 operators ZB BE101 and on the 8 th operator ZB BE10 XAC A ZB BE10 + ZB BE101 XAC A XAC A871 XAC A881 For control of -speed motors Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop + N/O + N/O staggered XEN G91 1 XAC A XAC A latching Emergency stop Ø 30 mm operator ZA BS (1) + N/O + N/O staggered XEN G N/O + N/O staggered XEN G91 3 ZB BE10 + N/C + N/C XEN T9 1 XAC A9 (1) XAC A91 (1) (1) To order a station with a trigger action latching Emergency stop Ø 30 mm operator (ZA BS83) or Ø 0 mm operator (ZA BS8), replace the number 3 in the reference selected by the number. Examples: XAC A671 becomes XAC A671 and XAC A9 becomes XAC A9. XAC A9 XAC A91 page 30075/ 5

5 References (continued) 6 Complete stations ready for use DF56558 For control of -speed motors (continued) Functions Number of operators Contact block(s) and scheme Reference Weight Per direction For Emergency stop + N/O + N/O XAC A staggered XEN G XAC A latching Emergency stop Ø 0 mm operator ZA BS5 (1) + N/O + N/O staggered XEN G N/O + N/O staggered XEN G91 3 ZB BE10 + N/C + N/C XEN T9 1 XAC A9 (1) XAC A91 (1) (a) (b) + N/O + N/O staggered (a) XEN G91 1 XAC A XAC A9 XAC A91 (b) ZB BE101 3 DF latching Emergency stop Ø 0 mm operator ZA BS5 (1) + N/O + N/O staggered (a) XEN G91 (b) ZB BE ZB BE10 1 XAC A93 (1) XAC A9 + N/O + N/O staggered (a) XEN G91 + N/C + N/C XEN T9 XAC A9 (1) (b) ZB BE101 (1) To order a station with a trigger action latching Emergency stop Ø 0 mm operator (ZA BS8), replace the number 3 in the reference selected by the number. Examples: XAC A9 becomes XAC A9 and XAC A91 becomes XAC A91. XAC A93 XAC A9 page 30075/ 6

6 References 6 Empty enclosures 530 Empty enclosures Description Enclosure comprising: - the enclosure, - internal mounting plate, - protective cable sleeve, - internal cable clamp, - suspension ring, - cable tie (for tightening sleeve onto cable). Number of cut-outs Reference Weight XAC A XAC A03 (1) 0.0 XAC A0 XAC A XAC A05 (1) 0.65 XAC A03 6 XAC A XAC A XAC A Variable composition stations, factory assembled Use the order form on page 30075/17 to defi ne the required configuration. Equipment: contact blocks, operating heads (control and signalling), complementary accessories See separate components, pages 30075/8 to 30075/ (1) Enclosures with 3 cut-outs XAC A03 and 5 cut-outs XAC A05 cannot be fitted with a mounting adaptor for base mounted units. XAC A1 page 30075/ 7

7 References 6 Separate components and spare parts Contact blocks for front mounting Description Application Function Scheme Reference Weight Single block, spring return slow break Single-speed N/O ZB BE ZB BE101 ZB BE10 N/C ZB BE N/C + N/O + N/O simultaneous (1) 1 3 XEN G speed N/C + N/O + N/O staggered (1) 1 XEN G XEN G91 XEN G Double block, latching slow break () Single-speed N/O N/O XEN G XEN G3781 XEN G3791 XEN T9 N/O N/C Isolating switch, slow break, for front mounting For mounting in enclosures XAC A03 (frontal cut-out) XAC A05, A06, A08 (frontal or base cut-out) XEN G Application Function Scheme Reference Weight Emergency stop N/C + N/C + N/C with positive opening operation XEN T (1) Only for use with XAC A9ppp operators. () Not suitable for use with the following operating heads: ZA BB, ZA BD, ZA BG and ZA BS.. page 30075/ 8

8 References (continued) 6 Separate components and spare parts 5300 Contact blocks for base mounting Description Function Scheme Reference Weight Spring return slow break (1) N/O XAC S XAC S10p N/C XAC S N/O + N/O XAC S N/C + N/C XAC S N/C + N/O XAC S ZB BV006 Pilot light bodies for front mounting Description Supply voltage Scheme Reference Weight Direct supply Bulb not included () y 00 V X1 ZB BV X 530 Direct supply, through resistor Incandescent BA 9s base fi tting 0 V bulb included 30 V X1 ZB BV X ZB BV007 (1) Not suitable for use with 3-position operating heads ZA BD and ZA BG or for mounting in enclosures XAC A039 and XAC A03. () Bulb type for use with direct supply units: BA 9s base fi tting incandescent bulb U y 0 V or neon bulb 0 V y U y 00 V. Maximum power:.6 W, maximum Ø: mm, maximum length: 8 mm. See page 30075/9.. page 30075/ 9

9 References (continued) 6 Separate components and spare parts 5303 XAC A9pp Operating heads for front mounting Description Colour Sold in lots of Unit reference Weight Booted operators White 10 XAC A Black 10 XAC A Green 10 XAC A ZA BS5 Red 10 XAC A Yellow 10 XAC A Blue 10 XAC A ZA BS83 ZA BS Brown 10 XAC A Operating heads for front or base mounting Description Colour Type Reference Weight Mushroom head, latching Turn to release (Emergency stop function) Red Ø 30 mm ZA BS 0.00 Ø 0 mm ZA BS Mushroom head, trigger action, latching Turn to release (Emergency stop function) Red Ø 30 mm ZA BS Ø 0 mm ZA BS ZA BDp Mushroom head, latching Key release (n 55) Key withdrawal in rest (unactuated) position (Emergency stop function) Red Ø 30 mm ZA BS Ø 0 mm ZA BS Selector switches, standard handle (Not to be used with XEN Gpppp contact blocks) Black position, stay put ZA BD position, stay put (1) ZA BD ZA BGp Key switches (key n 55) Key withdrawal in left and right-hand positions position, stay put ZA BG position, stay put (1) ZA BG5 0.0 DF56559 ZA BBp Wobblesticks () Operates in all directions for fast stop Black ZA BB Red ZA BB (1) Only suitable for front mounting. () Base mounting recommended. Other versions Key release mushroom head pushbuttons with other key numbers. Selector switches with other mechanical functions. Key switches with other mechanical functions and with other key numbers. Please consult your Regional Sales Offi ce. page 30075/ 10

10 References (continued) 6 Separate components and spare parts ZA BV0p 5300 Pilot light heads Description Colour Reference Weight For use with incandescent bulbs Lens cap White ZA BV with fi xing bezel Green ZA BV Red ZA BV DL1 Cpppp DL1 CFppp Yellow ZA BV Blue ZA BV Clear ZA BV DF5655 XAC A009 For use with neon bulbs Lens cap with fi xing bezel Green ZA BV Red ZA BV Yellow ZA BV Clear ZA BV XAC A960 DF ZB SZ3 Bulbs Description Voltage Sold in lots of Incandescent BA 9s base fi tting Maximum power:.6 W Maximum Ø: mm Maximum length: 8 mm Unit reference Weight 6 V 10 DL1 CB V 10 DL1 CE V 10 DL1 CE V 10 DL1 CE V 10 DL1 CE XAC B961 XAC A971 Neon BA 9s base fi tting Maximum power:.6 W Maximum Ø: mm Maximum length: 8 mm 0 V 10 DL1 CF V 10 DL1 CF V 10 DL1 CF Complementary accessories, tools Description Reference Weight Protective cable sleeve For cable Ø 8 to mm XAC A XAC A98 For cable Ø 8 to 6 mm XAC A Mechanical interlock for With fi xing screws XAC A operators Blanking plug With seal and fi xing nut ZB SZ Adaptor for self-supporting cable type BBAP Mounted with protective sleeve for cable Ø 8 to 6 mm XAC B Lower support ring XAC A XAC A983 Protective guards for base mounted units For selector switch (standard handle) or mushroom head pushbutton For key switch or key release latching mushroom head pushbutton XAC A XAC A Bulb extractor For BA 9s base fi tting bulbs XBF X XBF X page 30075/

11 References 6 Legends 30 x 0 mm with symbols conforming to NF E Function Symbol Reference Weight Function Symbol Reference Weight Raise, slow ZB BY Lower, slow ZB BY White bacround, black symbol Raise, fast ZB BY Lower, fast ZB BY Raise, slow-fast ZB BY Lower, slow-fast ZB BY Black bacround, white symbol Right, slow ZB BY Left, slow ZB BY Red bacround, white symbol Right, fast ZB BY Left, fast ZB BY Right, slow-fast ZB BY Left, slow-fast ZB BY Forward, slow ZB BY Reverse, slow ZB BY Forward, fast ZB BY Reverse, fast ZB BY Forward, slow-fast ZB BY Reverse, slow-fast ZB BY Slew right, slow ZB BY Slew left, slow ZB BY Slew right, fast ZB BY Slew left, fast ZB BY Slew right, slow-fast ZB BY Slew left, slow-fast ZB BY Slow ZB BY Fast ZB BY Klaxon ZB BY Start-Klaxon ZB BY Start ZB BY Stop ZB BY page 30075/ 1

12 References 6 Legends 30 x 0 mm 530 White Black Red Text Reference Weight b Start functions: white characters on black bacround b Stop functions: white characters on red bacround Text Reference Weight ZB BY101 Blank Black or red bacround ZB BY White or yellow bacround ZB BY Black White Yellow With French text With English text For pushbuttons For pushbuttons Marche ZB BY Start ZB BY Arrêt ZB BY Stop ZB BY Avant ZB BY Forward ZB BY ZB BY101 Arrière ZB BY Reverse ZB BY Montée ZB BY Up ZB BY Descente ZB BY Down ZB BY Droite ZB BY Right ZB BY Gauche ZB BY Left ZB BY En service ZB BY On ZB BY Hors service ZB BY Off ZB BY Sous tension ZB BY Power on ZB BY Lent ZB BY Slow ZB BY Vite ZB BY Fast ZB BY Klaxon ZB BY For selector switches For selector switches Arrêt-Marche ZB BY Hors-En ZB BY Off-On ZB BY With special texts b Specify text when ordering, b lines maximum, characters per line. White characters on black bacround White characters on red bacround Other versions ZB BY Black characters on white bacround ZB BY Black characters on yellow bacround Legends with texts in other languages. Please consult your Regional Sales Offi ce. ZB BY ZB BY page 30075/

13 Dimensions 6 Dimensions XAC A pendant stations for control circuits internal Ø Number of operators b b c (1) For and 3-way XAC A stations. () For and 8-way XAC A stations. (3) With mushroom head operator. () With trigger action mushroom head operator. Protective guards XAC A98 XAC A page 30075/ References: pages 30075/3 and 30075/

14 Application schemes 6 Application schemes (typical examples) For control of single-speed reversing motor Contact blocks ZB BE101 + ZB BE10 For control of -speed reversing motor contact blocks XEN G91 1 S1 S1 1 3 S 1 3 S 1 S S1 KM A1 KM1 A1 A A KM1 KM KM A A1 A A1 A A1 KM: high speed contactor page 30075/ References: pages 30075/3 and 30075/ 15

15 Presentation 6 16

16 Order form (specimen suitable for photocopying) 6 Variable composition stations, pre-assembled Customer Schneider Electric Industries Company Order N Delivery date Sales offi ce - Subsidiary Co. Order N Enter the order with XAC A09 reference Unit reference of empty enclosure, see page 30075/7 Number of identical stations Enclosure price (1) XAC A 1 Legends see pages 60075/1 and 30075/ Contact blocks or pilot light bodies see pages 30075/8 and 30075/ 9 Operating heads or pilot light heads or blanking plug see pages 30075/10 and 30075/ Reference Unit price Reference Unit price Reference Unit price Total price Unit mounted in base of enclosure (if required) (Except when using XAC A03 and XAC A05) Complementary accessories, see page 30075/ (cross the appropriate box or boxes) Description Reference Unit price Adaptor for self-supporting cable type BBAP for XAC B961 use with cable entry sleeve Ø 8 to 6 mm 15 Lower support ring XAC A Protective guard for selector switch (std. handle) or XAC A98 mushroom head pushbutton, mounted in base 17 Protective guard for key switch or key release XAC A983 mushroom head pushbutton, mounted in base Mechanical interlocking () Reference Quantity Unit price 17 XAC A009 Pre-assembled: Number of heads or blanking plugs to be fitted X Additional cost XAC 9VA for fi tting of 1 head or 1 blanking plug Total price of assembled pendant station (1) Obtain the empty enclosure price. () Connect with a line the ways which require mechanical interlocking. Examples: combinations possible Combinations not possible

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M Characteristics Pendant control stations, for control circuits Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 XAC-B : standard version : NEMKO, CSA 300 V type 4 Approvals XAC-M : standard

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 For control circuits Environment Conformity to standards EN/IEC 6097-5-1, CSA C22-2 n Product certifications XAC B Standard version: CSA 300 V type XAC M Standard version: CSA 300 V type

More information

Pendant control stations 6

Pendant control stations 6 Characteristics Pendant control stations For control circuits Environment Conformity to standards EN/IEC 0--, CSA C- n Product certiþ cations XAC B Standard version: CSA 00 V type XAC M Standard version:

More information

Control stations and enclosures 0

Control stations and enclosures 0 Characteristics Environment Conformity to standards IEC 947-5-1, EN 60 947-5-1, IEC 337-1, NF C 63-0, VDE 0660-200 Product certifications Standard version DEMK, NEMK, SÄHKÖTARKASTUSKESKUS, ASE Specia version

More information

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights Characteristics 1 Environment Protective treatment Standard version TH Ambient air temperature Storage C - 40 + 70 around the device Operation C - 25 + 70 for LED and neon bulb versions - 25 + 40 for incandescent

More information

Components for safety applications

Components for safety applications Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages

More information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Characteristics 5 TeSys k contactors and reversing contactors

Characteristics 5 TeSys k contactors and reversing contactors 90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to

More information

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Electromechanical pressure and vacuum switches 0

Electromechanical pressure and vacuum switches 0 30350-EN_Ver6..fm/ Presentation Electromechanical and vacuum switches 0 Nautilus For control circuits, type XML Pressure and vacuum switches type XML are switches for control circuits. They are used to

More information

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition

More information

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil Product data sheet Characteristics LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Complete units: Push-buttons ø 22mm

Complete units: Push-buttons ø 22mm Complete units: Push-buttons ø 22mm FLUSH SPRING RETURN - NON-ILLUMINATED Chrome Bezel Part Number Technical Info (p. 103) Black Bezel Part Number 11 Ø 29.9 20.1 19.6 With single position clip Red NC L21AA01-1E01

More information

Complete units: Mushroom heads ø 22mm

Complete units: Mushroom heads ø 22mm Complete units: Mushroom heads ø 22mm MAINTAINED - NON-ILLUMINATED Ø 40 MUSHROOM Push-pull to reset Technical Info (p. 103) Black Bezel Part Number 34.2 Ø 40 Red NC L22DD01-3E01 Red 2 NC L22DD01-3E02 Red

More information

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil Product data sheet Characteristics LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Control Stations ø 22

Control Stations ø 22 Control Stations ø 22 CONTROL STATIONS - NON-ILLUMINATED Technical Info (p. 103) MUSHROOM HEAD Ø 40 - MAINTAINED Push-turn to reset Part Number M16/20 47.9 25.7 Ø 40 Red NC EMERGENCY STOP LBX10510 Red

More information

Complete units: Selector switches ø 22mm

Complete units: Selector switches ø 22mm Complete units: Selector switches ø 22mm SELECTOR SWITCHES - NON-ILLUMINATED Technical Info (p. 13) WITH KNOB 2 and 3 positions Chrome Bezel Part Number Black Bezel Part Number Ø 29.9 Maintained positions

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB Characteristics interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB Main Range of product Series name Product or component type Device short name Contacts type and composition

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm ONE-PIECE PILOT LIGHTS Technical Info (p. 103) SUPPLIED WITHOUT BULB Part Number L20SA40 14.3 44.1 Ø 29.8 Ø 20.2 Ø 22 Ø 29.5 1 to 6 6 Ribbed Lens Clear Smooth Lens With text or symbol

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm SPRING RETURN - NON-ILLUMINATED Technical Info (p. 103) FLUSH-FLUSH Twin touch Chrome Bezel Part Number Black Bezel Part Number 12.3 11 53.9 29.9 With International Symbols Green

More information

FM series position switches

FM series position switches FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass

More information

Motor starters. TeSys E. Designed for the essential

Motor starters. TeSys E. Designed for the essential Motor starters TeSys E Designed for the essential Designed for the essential Contents TeSys E contactors, 6 A to 300 A TeSys E thermal overload relays 0.1 A to 333 A TeSys E control relays 4 NO/NC contacts

More information

Separate units: Blocks

Separate units: Blocks Separate units: Blocks LED BLOCKS Technical Info (p. 103) SCREW TERMINALS Part Number 3.8 LED 19.7 20.1 X1 X2 33EARL 9.9 19.7 21.5 18.2 12/24 V White Red Green Blue Yellow 33EAWL 33EARL 33EAGL 33EABL 33EAYL

More information

Position switches FM series

Position switches FM series B Position switches FM series Selection diagram 0 08 0 A A 0 A 0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket 69 stainless steel round rod square rod fiber

More information

Safety switches with slotted hole lever

Safety switches with slotted hole lever Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the

More information

LR Position Switches TECHNICAL DATASHEET

LR Position Switches TECHNICAL DATASHEET TECHNICA DATASHEET Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 69 contact blocks available actuators available M assembled connector versions Silver

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Charlie. Pendant control station. Industrial lifting. Construction lifting. Stage technology. Industrial automation

Charlie. Pendant control station. Industrial lifting. Construction lifting. Stage technology. Industrial automation Charlie Pendant control station Charlie pendant station is a control device for all industrial machinery. It operates as an auxiliary controller of electrical motors through a power interface, such as

More information

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 Presentation Thermal-magnetic motor circuit-breakers types GV, GV and GV7 GV-ME, GV-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control

More information

Components for safety applications Preventa safety modules

Components for safety applications Preventa safety modules Selection guide Applications Modules For Emergency Stop and limit switch monitoring (modules integrated in Micro PLCs) Conforming to standards Machine IEC 204-, EN 292, EN 48 assemblies EN 60204- Principles

More information

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED Characteristics interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED Product availability : Stock - Normally stocked in distribution facility Price* : 7.20 USD Main Range of

More information

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750 Characteristics Contact characteristics of mini-control relays and instantaneous contact blocks Number of contacts On CAp-K 4 On L-K 2 or 4 for C-K and CA3-K: 2 for CA4-K Rated operational voltage (Ue)

More information

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching Main Characteristics: Zero-point switching LED display Various connection technologies Plug-in control terminal Degree of protection IP 2 Insulated mounting foot Standards / Approvals: DIN EN 697--3 UL

More information

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC Characteristics off-delay timing relay with control contact - 0.05..1 s - 24 V AC DC - 2OC Product availability : Stock - Normally stocked in distribution facility Price* : 189.00 USD Main Range of product

More information

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC Characteristics adjustable on-delay timing relay - 0.05..1 s - 24 V AC DC - 2OC Price* : 189.00 USD Discontinued Main Range of product Product or component type Contacts type and composition Component

More information

Protection components

Protection components Multifunction protection relays LT-P Environment Conforming to standards IEC 947-4-1, IEC 34-11, IEC 755, VDE 010, VDE 00. &Ãmarking Meets the essential requirements of the Low Voltage equipment (LV) &

More information

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC Characteristics adjustable symmetrical flashing relay - 0.05..1 s - 24 V AC DC - 2OC Price* : 202.00 USD Discontinued Main Range of product Product or component type Contacts type and composition Component

More information

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC Characteristics time delay relay 8 functions - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range

More information

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE PUSHBUTTON SWITCH / SEECTOR SWITCH / IUMINATED PUSHBUTTON SWITCH PSA, PSA TYPE FEATURES 1 3 The PSA and SPSA types are oil-proof. The enclosure rating is IP65 (water-jet-proof type), covering wide applications.

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

Wireless and batteryless pushbuttons

Wireless and batteryless pushbuttons Wireless and batteryless pushbuttons Harmony XBR Catalogue April 0 This document provided by Barr-Thorp Electric Co., Inc. 00-- This document provided by Barr-Thorp Electric Co., Inc. 00-- AR00-EN.indd

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component

More information

Actuators Series 8602/3

Actuators Series 8602/3 > Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons

More information

Zelio Control Measurement Relays

Zelio Control Measurement Relays Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and

More information

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC

More information

Protection components

Protection components General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device

More information

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

Increased safety - Group IIC XAWP series. Glass-reinforced polyester (GRP) -20 C C INERIS03ATEX0122X

Increased safety - Group IIC XAWP series. Glass-reinforced polyester (GRP) -20 C C INERIS03ATEX0122X Pendant stations ncreased safety - Group C XAWP series The pendant stations XAWP are suitable for all types of industry and primarily used on overhead cranes, cranes. They are available with 2, 4, 6 or

More information

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17LLBM asymmetrical flashing relay s V AC - solid state output Characteristics asymmetrical flashing relay - 0.1..1 s - 24..240 V AC - solid state output Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 75.00 USD Main Range

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay

More information

Accessories. Accessories

Accessories. Accessories Series 61 16mm 22.5mm 21 x 21mm 21 x 27mm IP65 5 250V INDITOR PUSHUTTON E-STOP KEYLOK SELETOR hoose one component from each of the coloured sections to assemble a complete switch. For other options or

More information

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below. Bulletin H Product verview/specifications Bulletin H/ Hazardous locations push buttons and stations Classes I, II & III Divisions & / in. - NPSM barrel Type & Explosion-proof operators Table of Contents

More information

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton Edition 10/2016 HMI Components 41 Series Characteristics The rectangular design of the Series 41 (18 x 24 mm) makes it especially suited: Raised design PCB (with adaptor) Functions The Series 41 incorporates

More information

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance

More information

Datasheet - ZQ N

Datasheet - ZQ N 20.07.2016-17:41:15h Datasheet - ZQ 900-13N Pull-wire emergency stop switches / ZQ 900 Preferred typ Metal enclosure one-side operation / wire up to 75 m long Release push button Position indicator Robust

More information

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light. isw switches DB88 PB0566-40 Position contact indication b Suitable for industrial isolation according to IEC/EN 60947-3 standard. b The presence of the green strip guarantees physical opening of the contacts

More information

Detecting Devices. 8/2 Introduction

Detecting Devices. 8/2 Introduction Detecting Devices /2 Introduction /4 General data / 3SE5, plastic enclosures /16 3SE2, plastic enclosures /22 3SE5, metal enclosures /30 3SE2, metal enclosures /39 3SE3, metal enclosures Compact design

More information

Type Nominal voltage (V) Code HSV V

Type Nominal voltage (V) Code HSV V Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works

More information

Subject to changes 11/2003 Page 1/7

Subject to changes 11/2003 Page 1/7 Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 42.90 USD Main Range of product Product or component

More information

A W - A 2A R - 24D - 1

A W - A 2A R - 24D - 1 Knob-type Selector Switch A165S/W Mounting Aperture of 16 mm Modular construction Oil-resistant IP65 models UL and cul approved. Conforms to EN60947-5-1, IEC947-5-1 Short mounting depth, less than 28.5

More information

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A Load break switches standards UL and CSA The solution for Load break switches sircm_1_a_1_cat > Power distribution Strong points Function Rotary switch SRCO M 3 x 1 A SRCO M load break switches are compact

More information

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts Emergency pull-wire switches ZS 71... NA Technical data Contact variations * 63 mm for version 200 N pre-tensioning force To EN 418/IEC 60947-5-5 Metal enclosure 2 contacts Integrated emergency-stop button

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC Characteristics time delay relay 10 functions - 1 s..100 h - 12..240 V AC/DC - 1 OC Product availability : Stock - Normally stocked in distribution facility Price* : 75.00 USD Main Range of product Product

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton Edition /204 HMI Components 8 Series Characteristics The compact 8 mm Series 8 is especially suited for: Flush design Raised design PCB (with adaptor) Functions The Series 8 incorporates the following

More information

Wireless, Batteryless Push Buttons

Wireless, Batteryless Push Buttons Wireless, Batteryless Push Buttons Harmony XBR Catalog 0 Introduction Figure A: radio transmission between transmitter and receivers Figure B: radio transmission between transmitters and receiver Introduction

More information

Specifications. Safety Ratings. Standards. Safety Classification

Specifications. Safety Ratings. Standards. Safety Classification General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0

More information

Zelio Plug-In Relays. RXG interface relays. Catalog

Zelio Plug-In Relays. RXG interface relays. Catalog Zelio Plug-In Relays Catalog 204 Contents Zelio Plug-In Relays bbintroduction.... 3 bbspecifications.................................................... 4 bbreferences... 7 bbdimensions.... 0 bbwiring

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals

More information

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW Characteristics soft starter for asynchronous motor - ATSU01-32 A - 200..480V - 7.5..15 KW Main Range of product Product or component type Product destination Product specific application Device short

More information

DISCONNECT SWITCHES. UL Listed CSA Certified

DISCONNECT SWITCHES. UL Listed CSA Certified POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole

More information

Switches & Pilot Devices

Switches & Pilot Devices ømm - HW Series Key features: ocking lever removable contact blocks Finger-safe IP0 contacts as standard, other terminal styles available Tamperproof construction All E-stops meet EN8 and are compliant

More information

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW Characteristics soft starter for asynchronous motor - ATSU01-22 A - 200..480 V - 4..11 KW Price* : 195.00 GBP Main Range of product Product or component type Product destination Product specific application

More information

Breakcontact,Front. Articleno Deliveryprogramme. Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories

Breakcontact,Front. Articleno Deliveryprogramme. Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Breakcontact,Front Partno. M22-K01 Articleno. 216378 Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA, IEC Construction size NZM1/2/3/4

More information

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors. Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring

More information

Control and signalling units Ø 16

Control and signalling units Ø 16 References Pushbutton caps - unmarked (Sold in lots of 10) Application Colour Unit reference Weight Head Head Head Illuminated White ZB6-YDW1 ZB6-YCW1 ZB6-YAW1 0.001 with flush push Green ZB6-YDW3 ZB6-YCW3

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

Phase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement

More information