1.3. Pushbuttons and Indicating Lights.

Size: px
Start display at page:

Download "1.3. Pushbuttons and Indicating Lights."

Transcription

1 .3 Pushbuttons and Indicating Lights Pushbutton Control Stations Contents Page Features V7-T-5 Product Selection M22 Assembled Control Stations V7-T-6 Commercial Control Stations V7-T-7 General Purpose Control Stations V7-T-8 Special Purpose Control Stations V7-T H Series Heavy-Duty Control Stations V7-T T Series Heavy-Duty 30.5 mm Control Stations V7-T-2 Class I Division T Series Heavy-Duty 30.5 mm Control Stations V7-T-22 Class I Division 2 E34 Series Corrosion Resistant 30.5 mm Control Stations.... V7-T-23 Accessories V7-T-23 Custom Assembled Stations Specification Form V7-T-24 Renewal Parts V7-T-26 Technical Data and Specifications V7-T-28 Dimensions V7-T-28 Product M22 Assembled Control Stations M22 series operators Available in horizontal and vertical configurations Impact resistant polycarbonate enclosures Optional yellow covers Base mounting contact blocks and light units for quick wiring and vibration resistance Commercial Control Stations 0250T series operators Full front label Specific function labels on front of enclosure General Purpose Control Stations Construction grade General purpose wall mount Popular with contractors UL (NEMA) Type Special Purpose Control Stations Standard grade Polyester enclosure UL (NEMA) Type 3, 3R, 4, 4X, H Series Heavy-Duty Control Stations 0250H Series operators Dark brown polyester enclosure Protective rubber gaskets provide NEMA 3S rating on s Top and bottom 3/4 in NPT conduit entrances Includes alternate legend plates and spare mounting screws 0250T Series Heavy-Duty 30.5 mm Control Stations 0250T Series operators ASA 6 gray die-cast zinc enclosures Surface or flush mounting Single 3/4 in NPT conduit entrance on one and two element stations Single in NPT conduit entrance on three element stations Class I Division T Series Heavy-Duty 30.5 mm Control Stations 0250T Series operators Factory sealed contact blocks Die-cast, polyester or stainless steel enclosures Approved for NEC Class I Division 2, Groups B, C and D or Class I Zone 2 Group IIB plus Hydrogen type hazardous locations Class I Division 2 E34 Series Corrosion Resistant 30.5 mm Control Stations E34 Series operators Factory sealed contact blocks Die-cast, polyester or stainless steel enclosures Approved for NEC Class I Division 2 Groups B, C and D or Class I Zone 2 Group IIB plus Hydrogen type hazardous locations V7-T-4 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December 203

2 Pushbuttons and Indicating Lights.3 Features M22 Assembled Control Stations IP66, UL (NEMA) Type 4X, 3 Impact resistant polycarbonate enclosures Optional yellow cover 25% smaller depth than most competitor enclosures Base mounting contact blocks and light units for faster wiring and vibration resistance Commercial Control Stations ASA 6 gray die-cast zinc enclosures Pre-assembled and labeled for functions such as Fuel Shut-Off Great for commercial applications General Purpose Control Stations Construction grade General purpose wall mount Popular with contractors UL (NEMA) Type Special Purpose Control Stations Standard grade Polyester enclosure UL (NEMA) Type 3, 3R, 4, 4X, H Series Heavy-Duty Control Stations Industrial grade Extra heavy-duty Polyester enclosure Booted buttons Outdoor installation UL (NEMA) Type 3, 3R, 3S, 4, 4X, 2, T Series Heavy-Duty 30.5 mm Control Stations 30.5 mm operators Industrial grade Zinc die cast enclosure Popular with industrial end users UL (NEMA) Type 4, 4X, 2, 3 Class I Division 2 Control Stations Available with 0250T or E mm operators Zinc die cast, polyester or stainless steel enclosures Factory-sealed contact blocks Popular with industrial end users UL (NEMA) Type 4, 4X, 2, 3 NEC Class I Division 2 Groups B, C and D Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December V7-T-5

3 .3 Pushbuttons and Indicating Lights Product Selection M22 Assembled Control Stations One Element Control Stations Orientation Color Inscription Two Element Control Stations Element Orientation Color Inscription Three Element Control Stations Element Orientation Color Inscription Notes For assembled control stations not found in this selection, please contact the Eaton Technical Resource Center at -877-ETN CARE ( ) or Contact block configuration. Cover Color Horizontal 40 mm mushroom head push-pull emergency stop operator Red NC Yellow M22-C-MH Horizontal 40 mm illuminated mushroom head push-pull emergency stop Red NO-NC Yellow M22-C-M2H operator, Vac Horizontal 40 mm mushroom head twist-to-release emergency stop operator Red NC Yellow M22-C-M3H Horizontal 40 mm mushroom head key-release emergency stop operator Red NC Yellow M22-C-M4H Horizontal Flush Green NO Gray M22-C-M5H Horizontal Flush Green NO START Gray M22-C-M6H Horizontal Extended Red NC Gray M22-C-M7H Horizontal Extended Red NC STOP Gray M22-C-M8H Horizontal Key-operated selector switch, two-position maintained NO OFF-ON Gray M22-C-M9H Horizontal Knob type selector switch, three-position maintained 2NO HAND 0 AUTO Gray M22-C-M0H Horizontal Double Green NO START Gray M22-C-MH Red NC STOP Element 2 Color Inscription Cover Color Horizontal Extended Red NC Flush Green NO Gray M22-C2-MH Vertical Flush Green NO START Extended Red NC STOP Gray M22-C2-M2V Vertical Flush Black NO FORWARD Flush Black NO REVERSE Gray M22-C2-M3V Horizontal Vertical Horizontal Vertical Vertical Vertical Extended Indicating light Flush Flush Flush Flush Red NC Indicating light White Vac Flush Green NO Extended Black NO OPEN Extended Black NO FORWARD Flush Black NO UP Flush Element 2 Color Inscription White Vac Flush Green NO START Extended Red NC Flush Red NC STOP Flush Red NC STOP Flush Red NC STOP Flush Element 3 Color Inscription Cover Color Green NO Gray M22-C3-MH Red NC STOP Gray M22-C3-M2V Green NO Gray M22-C3-M3H Black NO CLOSE Gray M22-C3-M4V Black NO REVERSE Gray M22-C3-M5V Black NO DOWN Gray M22-C3-M6V V7-T-6 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December 203

4 Pushbuttons and Indicating Lights.3 Commercial Control Stations Key Specifications 30.5 mm (0250T series) operators ASA 6 gray die-cast zinc enclosures Industrial grade UL Type 4, 4X, 2, 3 Single 3/4 in NPT conduit entrance Dimensions in (mm) : 3.88 W x 4.00 H x 3.00 D (98.6 x 0.6 x 76.3) Operator:.63 D (to enclosure) x.50 diameter (4.4 x 38.) What is included? Eaton s pre-assembled, enclosed emergency stop stations include an operator, an enclosure, contact blocks and a variety of unique labels. Each label has white lettering on a red background indicating the function and red lettering on a white background indicating the operator type. Available s Catalog Number Operator Additional Contact Blocks (Sold Separately) Circuit Configuration Note Includes NO-NC contact block. Color Label 0250T5B62-S0 Push-Pull Gray EMERGENCY STOP 0250T5B62-S02 Push-Pull Gray EMERGENCY SHUT-OFF 0250T5B62-S03 Push-Pull Gray EMERGENCY GENERATOR STOP 0250T5B62-S04 Push-Pull Gray EMERGENCY HVAC SHUT-DOWN 0250T5B62-S05 Push-Pull Gray EMERGENCY ELECTRICAL DISCONNECT 0250T5B62-S06 Push-Pull Gray EMERGENCY BOILER SHUT-DOWN 0250T5B62-S07 Push-Pull Gray EMERGENCY CHILLER STOP 0250T5B62-S08 Push-Pull Gray EMERGENCY FUEL SHUT-OFF 0250T5B62-S09 Push-Pull Gray EMERGENCY REFRIGERATION STOP 0250T5B62-S0 Push-Pull Gray EMERGENCY POWER OFF 0250T5B62-S Push-Pull Gray EMERGENCY GAS SHUT-OFF 0250T5B62-S2 Push-Pull Gray EMERGENCY VENTILATION SHUT-DOWN 0250T5B62-S3 Push-Pull Gray GENERATOR 0250T5 0250T T 0250T3 0250T2 NC NO NO-NC 2NC 2NO Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December V7-T-7

5 .3 Pushbuttons and Indicating Lights General Purpose Control Stations Type N Control Stations UL (NEMA) Type Contact Symbol Button Type/Color Legends Single Button Station One Element Type with Padlock Attachment Accessory Flush/green START 0250H500 Selector Switch Two Button Station Three Button Station Three Button Station with Indicating Light Note Round button. Flush/red STOP 0250H50 Extended/red STOP 0250H504 Palm operated/black None 0250H89 Three-position selector switch/black knob RUN/OFF/AUTO 0250H289 Two Element Type Flush/red START/STOP 0250H5200 Flush/green extended/red START/STOP 0250H5207 Flush/black (all) RAISE/LOWER 0250H520 FOR/REV 0250H5202 OPEN/CLOSE 0250H5203 UP/DOWN 0250H5204 HIGH/LOW 0250H5205 FAST/SLOW 0250H5208 Three Element Type Flush/black (all) FOR/REV/STOP 0250H5300 UP/DOWN/STOP 0250H530 RAISE/LOWER/STOP 0250H5302 OPEN/CLOSE/STOP 0250H5303 FAST/SLOW/STOP 0250H5304 0/220V neon indicating light START/STOP Clear flush/green; flush/red 0250H530 Red flush/green; flush/red 0250ED853 Amber flush/green; flush/red 0250ED853-2 V7-T-8 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December 203

6 Pushbuttons and Indicating Lights.3 Selector Switch Two Button Station Mechanically Interlocked Pushbuttons Special Purpose Control Stations 0250H_ 0250H_ Type N Control Stations Open Type Construction (No Cover) Contact Symbol Button Type/Color Legends One Element Type Three-position selector RUN/OFF/AUTO 0250H2538 switch/black knob Two Element Type Flush/green START/STOP 0250H2747 Flush/black (all) mech. interlocked Special Purpose Control Stations UL (NEMA) Type 3, 3R, 4, 4X, 3 Contact Symbol Feature Legends One Element Pushbutton Type Flush START 0250H2738 Note No legend on buttons. Specify any standard legend. None STOP 0250H H658 With lock hasp STOP 0250H665 Two Element Pushbutton Type Flush START/STOP 0250H364 With lock hasp START/STOP 0250H67 Buttons interlocked FAST/SLOW 0250ED664 FOR/REV 0250H2740 UP/DOWN 0250H274 OPEN/CLOSE 0250H2742 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December V7-T-9

7 .3 Pushbuttons and Indicating Lights 0250H Series Heavy-Duty Control Stations 0250H_ 0250H_ 0250H_ Type H Control Stations UL (NEMA) Type 3, 3S, 4, 4X, 2, 3 Assembled Legend Element Type Feature Circuit Plate Unassembled Alternate Legend Plate One Element Pushbuttons Without padlock hasp NO-NC JOG START 0250H88 STOP RUN With padlock hasp NC STOP 0250H4239 Knob selector Two-position NO-NC OFF/ON 0250H4526 switch Three-position NO-NC MAN/OFF/AUTO 0250H4527 Two Element Pushbuttons Standard NO-2NC START/STOP 0250H884 2NO-2NC RAISE/LOWER FORWARD 0250H885 REVERSE OPEN CLOSE Standard and NO-2NC START/STOP 0250H4240 standard with padlock hasp Three Element Pushbuttons Standard 2NO-3NC FOR/REV/STOP START OPEN 0250H890 Two standard and JOG CLOSE 0250H424 standard with padlock hasp RAISE FAST LOWER SLOW Indicating light and s 20V Light-red lens and two plain NO-2NC MOTOR RUNNING START/STOP 0250H93 V7-T-20 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December 203

8 Pushbuttons and Indicating Lights T Series Heavy-Duty 30.5 mm Control Stations Break Glass Station One Element Two Element Three Element Break Glass Operator 6 Complete Assembled Stations UL (NEMA) Type 4, 4X, 2, 3 Element Type Features Contact Block(s) Legend Surface Mounting Flush Mounting 2 Break Glass Station Break glass station 3 Gray enclosure NC (logic level) EMERG. OFF 0250TGS Red enclosure 0250TGR One Element Pushbutton Standard NO-NC START 0250T T3573 NC STOP 0250T T3575 NO-NC None 0250T T3597 Mushroom head NO-NC START 0250T T3574 NC STOP 0250T T3576 With lock hasp 4 NC STOP 0250T T3577 Selector switch Two-position NO-NC OFF/ON 0250T T3580 black knob Three-position 2NO MAN/OFF/AUTO 0250T T358 black knob Push-pull Momentary 2NC START/STOP 0250T T3602 three-position red button Two Element Pushbuttons Standard NO-2NC START/STOP 0250T T3582 2NO-2NC RAISE/LOWER 0250T T3673 2NO-2NC None 0250T T3598 With lock hasp 4 NO-2NC START/STOP 0250T T3599 Standard and mushroom head NO-2NC START/STOP 0250T T3583 Standard with NO-NC START/STOP 0250T T3585 maintained contact 5 Plus NC Three Element Pushbuttons Standard 2NO-3NC FOR, REV, STOP 0250T T3589 2NO-3NC UP, DOWN, STOP 0250T365 2NO-3NC OPEN, CLOSE, STOP 0250T364 2NO-3NC None, None, STOP 0250T T3600 Two standard and with lock hasp 2NO-3NC None, None, STOP 0250T T360 Indicating light Red lens 20V NO-2NC MOTOR RUN, 0250T T3593 (transformer type) Red lens 240V START/STOP and s 0250T T3594 Red lens 480V 0250T T3595 Red lens 600V 0250T T3596 Break Glass Kit Operator with hammer and five glass discs Glass discs only (5) Notes 0250TBG 0250TGL Stop buttons are red all others are black. 2 NEMA 4 3, if properly mounted on a flat surface. Consists of front plate, legend, operator and contact blocks. 3 Break glass stations will not function with Normally Open contact blocks. 4 Lock is 0250TA2. 5 Uses deep cover instead of shallow cover. Switch component is 0250TA67 mechanically interlocked operators. 6 Shown assembled to contact block (contact block supplied separately). Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December V7-T-2

9 .3 Pushbuttons and Indicating Lights Class I Division T Series Heavy-Duty 30.5 mm Control Stations 0250T T7023P 0250T7033S Complete Assembled Stations UL (NEMA) Type 4, 4X, 2, 3; NEC Class I Division 2, Groups B, C and D Contact Symbol Single Pushbutton NO NC Two Pushbuttons NO NC Each Button Button Type/Color Legend Marking Die Cast Polyester Molded Stainless Steel Flush/green START 0250T T7003P 0250T7003S Extended/red STOP 0250T T7005P 0250T7005S Alum. jumbo EMER. STOP 0250T T7007P 0250T7007S mushroom/red (engraved button) Flush/black No legend 0250T T7009P 0250T7009S Flush/green START 0250T T7023P 0250T7023S Extended/red STOP Flush/black No legend 0250T T7025P 0250T7025S Flush/black No legend Single Pilot Light Two Pushbuttons 20 Vac red No legend 0250T T7033P 0250T7033S NO Flush/green START NC Extended/red STOP Each Button 20 Vac red No legend 0250T T7035P 0250T7035S Flush/black Flush/black Three-Position Selector Switch 2NO Maintained knob/black 2NC Maintained knob/black Single Pushbutton Maintained Push-pull with jumbo mushroom/red Pull O X Push X NO O NC HAND/OFF/AUTO 0250T T70P 0250T70S No legend 0250T T703P 0250T703S EMER. STOP (engraved button) 0250T T709P 0250T709S V7-T-22 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December 203

10 Pushbuttons and Indicating Lights.3 Class I Division 2 E34 Series Corrosion Resistant 30.5 mm Control Stations E34EX_ Accessories Padlock Attachment Complete Assembled Stations UL (NEMA) Type 4, 4X, 2, 3; NEC Class I Division 2, Groups B, C and D Contact Symbol Single Pushbutton NO NC Two Pushbuttons NO NC Each Button Button Type/Color Three-Position Selector Switch 2NO Maintained knob/black 2NC Maintained knob/black Single Pushbutton Maintained Push-pull with jumbo mushroom/red Pull O X Push X NO O NC Type N Control Stations Padlock attachment For field assembly on square button type (except extended button types) Legend Marking Note Use NEMA 4X 0250T operators where exposed to ultraviolet light, see Page V7-T-22. Die Cast Polyester Molded Stainless Steel Flush/green START E34EX7003 E34EX7003P E34EX7003S Extended/red STOP E34EX7005 E34EX7005P E34EX7005S Alum. jumbo EMER. STOP E34EX7007 E34EX7007P E34EX7007S mushroom/red (engraved button) Flush/black No legend E34EX7009 E34EX7009P E34EX7009S Flush/green START E34EX7023 E34EX7023P E34EX7023S Extended/red STOP Flush/black No legend E34EX7025 E34EX7025P E34EX7025S Flush/black No legend HAND/OFF/AUTO E34EX70 E34EX70P E34EX70S No legend E34EX703 E34EX703P E34EX703S EMER. STOP (engraved button) E34EX709 E34EX709P E34EX709S 0250H50 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December V7-T-23

11 .3 Pushbuttons and Indicating Lights Custom Assembled Stations Specification Form Ordering Instructions Step Copy this ordering guide from catalog. Step 2 Specify 0250T or E34 lines in the corresponding box on the following page. 0250T Pages V7-T-82 to V7-T-253 E34 Pages V7-T-254 to V7-T T and Pages E34 V7-T-32 to V7-T-36 Class I Div. 2 Step 3 Check back of panel dimensions specify single or double depth enclosure in the corresponding box on the following page. Step 4 Specify enclosure catalog number and price in the corresponding box on the following page. s can be found on Pages V7-T-6, V7-T-233 and V7-T-283. For pricing, reference the most recent PAD or VISTA-line. Step 5 Specify catalog numbers for desired operator, legend plate, light unit, accessory and contact block(s) for each location in the enclosure in the corresponding box on the following page. (See position locations on this page.) Position Position Position 2 Position Position 2 Position 3 Position Position 2 Position 3 Position 4 Position Locations Step 6 For non-standard legends, specify legend desired, letter size and location on the layout sketches on the following page. For limitations see Page V7-T-232. For pricing, use the blank legend catalog number and STAMP Suffix (Ex.: 0250TS36STAMP) and reference the most recent PAD or VISTA-line. Example: 0250TS36 Special Legend for Position # LETTER SIZE 3/32 in /8 in 3/6 in Step 7 Fax Sheet 2 of this form to Eaton s TRC, Technical Resource Center, at to the attention of Custom Stations Order or to TRC@eaton.com. Within a few days you will receive a confirmation fax with the custom station part number and price. Step 8 Place your order over the VISTA System. For Selector and Roto-Push Operators 0250T or E34 For single contact blocks or NO-NC contact blocks, the mounting position of contacts must be specified. For example: If a NO-NC contact block is required, specify if NO is to be mounted in Top A position or Bottom B position. V7-T-24 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December 203

12 Pushbuttons and Indicating Lights.3 To Step 2) 0250T STD Class I Division 2 E34 STD Class I Division 2 Step 5) Position Position Eaton s TRC, Custom Station Order (828) FAX, or to TRC@eaton.com From Customer Name Customer Contact Phone Number Fax Number Address Operator Legend Plate U.S. $ Light Unit U.S. $ Step 3) Single Depth Double Depth Contact Block Part Number Product Code Suffix Date Engineer U.S. $ A/L B/R Contact Block FACTORY USE ONLY Step 4) U.S. $ A/L B/R 0% Adder for Assembled Stations Step 6) Non-standard Legends Special Legend for Position # Special Legend for Position # Special Legend for Position # LETTER SIZE 3/32 inch (2.4 mm) /8 inch (3.2 mm) 3/6 inch (4.8 mm) U.S. $ Lens or Caps LETTER SIZE 3/32 inch (2.4 mm) /8 inch (3.2 mm) 3/6 inch (4.8 mm) U.S. $ Accessory U.S. $ LETTER SIZE 3/32 inch (2.4 mm) /8 inch (3.2 mm) 3/6 inch (4.8 mm) Total Total: Total Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December V7-T-25

13 .3 Pushbuttons and Indicating Lights Renewal Parts Type N Renewal Parts Assembled Stations Type N Item Req. Part Number Type N Square Buttons Cover Two element One element top button One element bottom button Cover screw Pushbutton support bracket Pushbutton support bracket screw Pushbutton spring Disc (when used two element assembly) Pushbutton top position START/green RAISE/black FORWARD/black OPEN/black UP/blank Blank/green Pushbutton bottom position STOP/red Extended STOP/red REVERSE/black CLOSE/black DOWN/black LOWER/black Blank/red Item Req. Part Number Type N Square Buttons, continued 9 Pushbutton element NO-NC NO NO NC Cover Pushbutton support bracket Pushbutton top position FORWARD/black UP/black RAISE/black OPEN/black FAST/black Pushbutton middle position REVERSE/black DOWN/black LOWER/black CLOSE/black SLOW/black Pushbutton bottom position STOP/red Pushbutton element 2NO-3NC Cover V7-T-26 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December 203

14 Pushbuttons and Indicating Lights.3 Assembled Stations Type N, continued Item Type H Renewal Parts Assembled Stations Type H Item Req. Part Number Type N Square Buttons, continued 7 Lens Clear Red Amber Shield Shield screws Lamp (neon NE48) Lamp receptacle Lamp receptacle screw 9-330F 23 Pilot light terminal base Lens Clear Red Amber Pushbutton support bracket Pushbutton element NO-NC Pushbutton Type H Assembled Stations Req. 7 Part Number Screw Screw Base Contact blocks See Page V7-T T operator See Pages V7-T-88 to V7-T Mounting plate Item Req. Part Number Type N Round Buttons Similar to 27 Pushbutton assembly and element for: 0250H H H H H H H H H H Indicating Light Selector Switch Item Type H Assembled Stations Req. 7 2 Part Number 7 Screw Diaphragm Mounting plate Gasket Base Mounting plate Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December V7-T-27

15 .3 Pushbuttons and Indicating Lights Technical Data and Specifications Ratings Maximum Ampere Ratings for Type N Control Stations Maximum Ampere Ratings for Type H Control Stations Dimensions Approximate Dimensions in Inches (mm) Type N Control Stations Special Purpose Control Stations Note 2.38 (60.5) for neon indicating light. Volts AC Volts DC Make and emergency interrupt capacity Normal load break Continuous current Volts AC 50/60 Hz Volts DC Make and emergency interrupt capacity Normal load break Continuous amperes Voltamperes Make and emergency interrupt capacity Normal load break (38.) 2.25 (57.2) 4.00 (0.6) 3.25 (82.6) a 2.25 (57.2) Single Button Station 2.25 (57.2) 3.3 (79.5) 5.50 (39.7) 6.25 (58.8).50 (38.) 2.25 (57.2) 0.75 (9.) Pipe Tap Ship Wt. 2.5 Lb (. kg) 4.00 (0.6) 3.25 (82.6) Two Button Station 3.38 (85.9) a 2.25 (57.2).50 (38.) 2.25 (57.2) 6.00 (52.4) 5.00 (27.0) Three Button Station a 2.25 (57.2) V7-T-28 Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December 203

16 Pushbuttons and Indicating Lights.3 Approximate Dimensions in Inches (mm) Type H Control Stations NEMA Type 3, 3R, 3S, 4, 4X, 3 of Dimensions Elements Wide High Deep and (4.3) 8.25 (209.6) 4.50 (4.3) (4.3) 0.75 (273.) 4.25 (08.0) 0250T and E34 Approximate Dimensions Surface Mounting Dimensions in In (mm) Number of Wide High Deep Mounting Elements A B C D E Cast 3.88 (98.6) (98.6) (98.6) (98.6) Polyester 3.8 (96.8) (96.8) (96.8) (96.8) Stainless Steel 3.00 (76.2) (88.9) (88.9) (88.9) 4.0 (0.6) 5.88 (49.4) 7.75 (96.9) 9.63 (244.6) 6.63 (68.4) 6.63 (68.4) 8.88 (225.6) 6.63 (68.4) 3.50 (88.9) 6.75 (7.5) 9.00 (228.6).25 (285.8) 3.0 (76.3) 3.0 (76.3) 3.0 (76.3) 3.0 (76.3) 3.38 (85.9) 3.38 (85.9) 3.38 (85.9) 3.38 (85.9) 3.00 (76.2) 3.00 (76.2) 3.00 (76.2) 3.00 (76.2) 2.69 (68.3) 2.69 (68.3) 2.69 (68.3) 2.69 (68.3) 2.94 (74.7) 2.94 (74.7) 2.94 (74.7) 2.94 (74.7).50 (38.).50 (38.).50 (38.).50 (38.) Note No conduit entrance holes provided. Drill as required (82.6) 5.3 (30.3) 7.0 (77.8) 8.88 (225.6) 4.88 (24.0) 4.88 (24.0) 7.3 (8.) 4.88 (24.0) 4.25 (08.0) 7.50 (90.5) 9.00 (228.6) 2.00 (304.8) Conduit Entrance 3/4 3/4 4 Mtg. Holes 0-32 Screw Size for 4 Element Die Cast/ Stainless Steel 7/32 Screw Size for Polyester D A E B Surface C Volume 7 Logic Control, Operator Interface and Connectivity Solutions CA E December V7-T-29

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below. Bulletin H Product verview/specifications Bulletin H/ Hazardous locations push buttons and stations Classes I, II & III Divisions & / in. - NPSM barrel Type & Explosion-proof operators Table of Contents

More information

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2 30.5 mm Stations Hermetically Sealed for Division 2/Zone 2 10 Bulletin 800R Hazardous Location Stations Classes I and II Division 2/Zone 2 30.5 mm Mounting Hole Types4/13and4/4X/13 0 TABLE OF CONTENTS

More information

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number Non-Illuminated Momentary Pushbutton Units Flush Button Extended Button Mushroom Button Jumbo Mushroom Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators Contact Type Button

More information

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only) 1-,, 3-, 4- Toggle Switches (Bul. 800T only) 800T T2 H2 E E X X a b c d e f g Right Left Right Left Blank C T1 T2 T3 T4 a Finger-Safe Guards Description No guards Guards on terminals b Operator Type Description

More information

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35 Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent ulletin 800T 30.5 mm Push uttons 2-Position Knob/Lever Type Selector Switch Units, Illuminated Operator Position Operator Type Standard Knob Knob Lever Type Lamp Volts olor M = Maintained S = Spring Return

More information

1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551

1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551 .7 Pushbuttons and Indicating Lights Contents escription 30.5 mm Square Multifunction Watertight/Oiltight E30 Product Identification.................... Product Selection Operators..........................

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

BVP SERIES Brass Lighting for Marine and Hazardous Environments

BVP SERIES Brass Lighting for Marine and Hazardous Environments BVP SERIES Brass Lighting for Marine and Hazardous Environments Class I, Division 2, Groups A, B, C & D Zone 2, Group IIA, IIB, IIC UL 844 Hazardous Locations UL 1598A Marine Outside Type NEMA 3, 4, 4X

More information

Actuators Series 8602/3

Actuators Series 8602/3 > Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons

More information

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover. AGUB Instrument and Meter Enclosures Furnished with aluminum body and solid or window cover. Class I, Division 1 and, Groups B, C, D Application To pull or splice wires and/or to mount and enclose electrical

More information

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S10N06P0P KVA 1PH 10/40V 16/3V Buck Boost Transformer Eaton Corp Catalog Manufacturer Description Weight per unit Product

More information

AVP SERIES Aluminum Lighting for Hazardous and Severe Environments

AVP SERIES Aluminum Lighting for Hazardous and Severe Environments AVP SERIES Aluminum Lighting for Hazardous and Severe Environments A V P Class I, Division 2, Groups A, B, C & D Zone 2, Group IIA, IIB, IIC UL 844 Hazardous Locations UL 1598A Marine Outside Type CUL

More information

Sensor Accessories Retroreflectors and Retroreflective Tape 8-2

Sensor Accessories Retroreflectors and Retroreflective Tape 8-2 - Retroreflectors and Retroreflective Tape PG.05E.17.T.E Retroreflectors Contents Overview.................... - Model Selection............... -3 Dimensions.................. -3 High Quality Retroreflectors

More information

Michigan State University Construction Standards WIRING DEVICES PAGE

Michigan State University Construction Standards WIRING DEVICES PAGE PAGE 262726-1 SECTION 262726 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications Blank Bodies for Brazed Hubs UNILETS for Use with Threaded Rigid Metal Conduit and IMC. Available with Hub Sizes from 1/2 through 1-1/2 (Union 1/2 through 1-1/4 ). Furnished with Internal Ground Screw.

More information

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box Concealed Service Floor Boxes 663 Series Floor Box 663-SC Multiple service floor box that delivers power, communications and data from standard conduit with no exposed service fitting Result: Open office

More information

Round Indicator Lights Mounting Hole Page

Round Indicator Lights Mounting Hole Page PRODUCT SERIES Round Indicator Lights Page 8, &. 9. &..7 - NEMA -R.7 8 & 9. 7. 8. 9 7. 8. - NEMA -R.9.9 Indicator Lights.7,.. 7. Rectangular Indicator Lights Panel Cutout. x.. x. 7 & 7. x.8 8. x. 9 & 7.

More information

Photoelectric Sensors E51 Limit Switch Style, Modular

Photoelectric Sensors E51 Limit Switch Style, Modular August 2007 E5 Limit Switch Style, Modular PG.05E.2.T.E E5 Modular Limit Switch Style Contents Overview...................... Model Selection, Assembled Sensors............. 2 Model Selection, Sensor Heads..................

More information

OPERATING USER MANUAL for PRESSURE RECORDERS

OPERATING USER MANUAL for PRESSURE RECORDERS Serial No. OPERATING USER MANUAL for PRESSURE RECORDERS MNW-004 Rev. F 01/04/19 Reorder Stock No. PD1013 Palmer Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853

More information

T S 15KVA 1PH 240/480 Transformer

T S 15KVA 1PH 240/480 Transformer 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T2535173S 15KVA 1PH 240/480 Transformer Acme Electric Catalog Number Manufacturer Description Weight per unit Product

More information

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires EVLP Low Profile (H.I.D.) Luminaires Medium and Cl. I, Div. 1, Groups B (GB suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (with suffix GB), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III Marine & Wet

More information

Local control stations for Zone 1 and Zone 21. Features. Description

Local control stations for Zone 1 and Zone 21. Features. Description Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning

More information

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant GAI-TRONICS A Hubbell Company PAGE/PARTY Solutions GAI-Tronics Page/Party communication systems provide paging and party-line capabilities... two important plant communication functions in one durable,

More information

FDM Medium Voltage Controller

FDM Medium Voltage Controller 1-1 LMR PLUS Product Description For over 50 years, EATON Corporation has been the industry leader in Medium Voltage Motor Control. The FDM Medium Voltage Fire Pump Controller is based on the AMPGARD controller

More information

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers .5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings

More information

Universal Voice Coil and 70 Volt Door Speaker V / V

Universal Voice Coil and 70 Volt Door Speaker V / V PagePac by ISSUE 2 Universal Voice Coil and 70 Volt Door Speaker V-5330120 / V-5330230 Installation Manual 947179 Your PagePac Door Speaker Note: The Door Phone Controller and PagePac 6 systems require

More information

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Optional end of travel limit switches for user setting of minimum and maximum pressure values. A M/P Converters Features (Varies with s) AC Control Unit (CC) Output pressure locks in last position in event of power failure. Continuous AC Motor unit is instant start-stop, heavy duty impedance protected

More information

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Optional end of travel limit switches for user setting of minimum and maximum pressure values. A M/P Converters Features (Varies with s) AC Control Unit (CC) Output pressure locks in last position in event of power failure. Continuous AC Motor unit is instant start stop, heavy duty impedance protected

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor Ideal for Detecting Labels on Bottles Satisfies the requirements of IP67. Ensures a vibration resistance of 10 Hz to 2 khz and a shock resistance of 1,000 m/s 2 (approximately 100G). Incorporates an NPN

More information

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations Areamaster Generation HL LED Luminaire Class I, Division, Groups A, B, C, D Class I, Zone Group IIC Class II, Division and, Groups E, F, G Zone and Group IIIC Zone, Group IIIB Type R,, X, IP66/67 Applications

More information

2.1. Product Description

2.1. Product Description .1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................

More information

Titan Series Awning Assembly and Installation Instructions

Titan Series Awning Assembly and Installation Instructions Titan Series Awning Assembly and Installation Instructions Be sure to use safety glasses when assembling and installing the awning. Some metal parts may have sharp edges. Use work gloves to handle them.

More information

CW-Type Wall Mounted Cabinets Installation Instructions

CW-Type Wall Mounted Cabinets Installation Instructions Instruction Sheet 860446194 Issue 2, March 2013 CW-Type Wall Mounted Cabinets Installation Instructions General CommScope wall mount cabinets are available in 24-inch (610mm), 36-inch (914mm) and 48-inch

More information

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations Industrial Areamaster Generation HL LED Luminaire Type R,, X Applications Powerful, efficient weatherproof lighting for applications such as: Security lighting Production facilities Warehouses Processing

More information

FSK1VDRA 1G Al DPLX RCPT CVR

FSK1VDRA 1G Al DPLX RCPT CVR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FSK1VDRA 1G Al DPLX RCPT CVR Appleton/Oz Gedney Catalog Number Manufacturer Weight per unit Product Category FSK1VDRA

More information

Baymaster LED Luminaire High Bay for Hazardous Locations

Baymaster LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

RSB-RCS/L SERIES The RSB-RCS/L Series rectangular shoebox is offered in a variety of lighting distributions with sharp cutoff to meet the challenging demands of today s site lighting projects. Fixture

More information

APES HD-7700 Version Operator s Training Manual

APES HD-7700 Version Operator s Training Manual APES-14-77 HD-7700 Version Operator s Training Manual Issue A1 09/03 P/N 900599 Performance Design Inc. 2350 East Braniff St. Boise Idaho 83716 This manual contains very important safety information and

More information

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Baymaster HL LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

Checkmate Stops & Holders. Absolute Door Control and Entire Opening Protection

Checkmate Stops & Holders. Absolute Door Control and Entire Opening Protection Checkmate Stops & Holders Absolute Door Control and Entire Opening Protection checkmate stops & holders TABLE OF CONTENTS General Information...3 How to Select Product...4 Options...5 Certifications...5

More information

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant PAGE/PARTY Solutions GAI-Tronics Page/Party communication systems provide paging and party-line capabilities... two important plant communication functions in one durable, easy-to-operate package. STATIONS

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Model 2400 Explosion-Proof M/P Converters -- LOCK IN LAST POSITION --

Model 2400 Explosion-Proof M/P Converters -- LOCK IN LAST POSITION -- A Explosion-Proof M/P Converters -- LOCK IN LAST POSITION -- Electrical AC Control Unit Motor Voltage...115vAC, 60Hz Power Consumption (watts) 10 Regulator...5(Max.) 16 Regulator...3(Max.) 80 Regulator...3(Max.)

More information

DISCONNECT SWITCHES. UL Listed CSA Certified

DISCONNECT SWITCHES. UL Listed CSA Certified POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use and High Performance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4 I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)

More information

REGATTA PATH LIGHT (RGP)

REGATTA PATH LIGHT (RGP) NEEDED FOR INSTALLATION: 5/64 & 5/32 Allen Wrench Waterproof Wire Connectors Warning Low Voltage Hot Surface Wear Gloves By Others Gloves IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION

More information

s tops & holder s Absolute Door Control and Entire Opening Protection

s tops & holder s Absolute Door Control and Entire Opening Protection check mate s tops & holder s Absolute Door Control and Entire Opening Protection Copyright 2001-2018, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or

More information

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series Heavy Duty Door Clamping Junction Box Padlock Kit www.hammfg.com Quick Release Clamp New note style replacement hardware for use on 1418N4, 1418N4SS, 1447SN4, and 1447SN4SS Hammond enclosures. Formed heavy

More information

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers INTERNATIONAL TRANSFORMERS Acme Electric s broad selection of CSA energy efficient transformers International Transformers What is CSA C802.2 Compliant? On January 1, 2005, the Canadian Energy Efficiency

More information

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations.  EATON 2.4.1 CEAG Products Main Catalogue Part : Chapter... Ex-Control units and control stations www.crouse-hinds.de EATON.. .. EATON www.crouse-hinds.de Ex-Control units and control stations Table of contents. GHG

More information

Process display RIA 261

Process display RIA 261 Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable

More information

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE PUSHBUTTON SWITCH / SEECTOR SWITCH / IUMINATED PUSHBUTTON SWITCH PSA, PSA TYPE FEATURES 1 3 The PSA and SPSA types are oil-proof. The enclosure rating is IP65 (water-jet-proof type), covering wide applications.

More information

Jefferson Electric Inc Product Catalog JE901

Jefferson Electric Inc Product Catalog JE901 Jefferson Electric Inc Product Catalog JE901 Worldwide Products and Services Tradition of Excellence Jefferson Electric has been a pioneer and innovator of magnetic products since 1915. We enjoy a rich

More information

Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2

Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 EVLS Hazard Gard A compact, affordable, explosionproof luminaire that has the best overall temperature performance ratings in its class! Eaton's Crouse-Hinds EVLS Hazard Gard is perfect as a general area

More information

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3. 6-4 Freedom Pump Panels Circuit reaker R Enclosure / -Phase Magnetic / Interchangeable eater OLR These ECN Irrigation Pump Controllers feature the Cutler-ammer Freedom Series starters. They have a AND/OFF/AUTO

More information

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient

More information

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator Service Outlet Quick Start Steps Keyed latch Cover 115VAC, 15A Plastic base Operator Unpack the Operator Site Planning and Operator Installation The illustrations and instructions presented in this guide

More information

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101 CustomAS-Interface enclosures Overview There are two types of custom solutions for AS-Interface: The front panel module and the SIRIUS 3SB3 enclosed stations. NC Contacts AS-Interface enclosure Ordering

More information

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find

More information

Adams Rite. Standard & Heavy Duty Deadlatches Series Heavy Duty Deadlatch

Adams Rite. Standard & Heavy Duty Deadlatches Series Heavy Duty Deadlatch Standard & Heavy Duty Deadlatches 4900 Series Heavy Duty Deadlatch Function: Flexibility of traffic control and installation is offered by the 4900 Series Deadlatches. A reverse turn of the key while bolt

More information

Level Lance Model 5100

Level Lance Model 5100 Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection

More information

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System Technical Data TD008010EN Supersedes February 2016 Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System The information below is taken directly from the National Electrical CodeT (NEC)

More information

PF/PFQ. High Amperage plug and receptacle. Main Advantages

PF/PFQ. High Amperage plug and receptacle. Main Advantages High Amperage plug and receptacle Main Advantages u u u Durable in harsh environments Safety features provide maximum protection Easy plug insertion and removal Watch the PF video and other product videos

More information

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome VIVOTEK SD83XXE Speed Dome Mounting Accessories AM-116/117 Pendant Pipe AM-118 Pendant Head AM-221 Gooseneck AM-231 Parapet Mount AM-519 Pendant Adaptor Installation Guide Corresponding part numbers: AM-116:

More information

1000 Watt Metal Halide Light - Hot Restrike - Multi-tap Ballast - Spot or Flood

1000 Watt Metal Halide Light - Hot Restrike - Multi-tap Ballast - Spot or Flood 1000 Watt Metal Halide Light - Hot Restrike - Multi-tap Ballast - Spot or Flood Part #: HID-22SL-HR The HID-22SL-HR 1000 Watt Metal Halide Light from Larson Electronics provides operators with the intensity

More information

10 Hazlux Lighting US Brochure

10 Hazlux Lighting US Brochure 0 Hazlux Lighting US Brochure Area lighting Hazlux 3 series Safe, durable, and now available with LED technology for superior energy efficiency, Thomas & Betts Hazlux products are the brand specifiers

More information

Section 11 Electronic Position Controls & Encoders

Section 11 Electronic Position Controls & Encoders APC-2006 All Products Catalog Section Electronic Position Controls & Encoders Force Control Industries, Inc. Main Office and Manufacturing Plant 3660 Dixie Highway Fairfield, Ohio 45014 Telephone: (513)

More information

Specifications. Safety Ratings. Standards. Safety Classification

Specifications. Safety Ratings. Standards. Safety Classification General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

INSTALLATION INSTRUCTIONS F Series Floodlight

INSTALLATION INSTRUCTIONS F Series Floodlight IMPORTANT: Read carefully before installing. All work should be performed by a qualified Electrician. These instructions may not provide directions to cover every variation and detail. To obtain additional

More information

Looking for a small band saw? The Ellis 1100 band saw might be just what you are looking for.

Looking for a small band saw? The Ellis 1100 band saw might be just what you are looking for. 1100 MITRE BAND SAW Looking for a small band saw? The Ellis 1100 band saw might be just what you are looking for. This portable band saw moves easily to the job site. Use it as horizontal or vertical saw.

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards IEC 97-5-1, EN 6097-5-1 Product certifications NEMKO. Special version: UL Listed A600-Q600, CSA A600-Q600 Protective treatment Standard version TH

More information

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON Heavy-duty Plug-in Photoelectric Sensor Water-resistive Photoelectric Sensor with Metal Housing & Plug-in Connector Ensuring Long Sensing Distance Satisfies the requirements of IP67, and NEMA6P. Ensures

More information

Single 180 Double 180 Triple. 180 Quad

Single 180 Double 180 Triple. 180 Quad Product Specifications FINISH Exclusive Colorfast DeltaGuard finish features an E-Coat epoxy primer with an ultra-durable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

MBC /602(L) MBC /602(L) MBC /602(L)

MBC /602(L) MBC /602(L) MBC /602(L) GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-... 1000/60(L) MBC-... 500/60(L) MBC-... 4000/60(L) Two normally closed automatic shutoff valves and servo regulator in one

More information

QL55 Series Luminescence Sensor

QL55 Series Luminescence Sensor Self-contained, microprocessor-based luminescence sensor Features Self-contained design in a robust, compact metal housing High sensitivity Microprocessor-controlled Senses luminescent marks, even on luminescent

More information

A great addition to Sub-Zero's complete line of

A great addition to Sub-Zero's complete line of with Refrigeration Drawers Discreet lighting Full-view glass door (standard) Roller-assembly shelves UV-resistant glass Lighted electronic control panel Divider gasket Model 427R Lighted display shelf

More information

A. Product Data: For each electrical identification product indicated.

A. Product Data: For each electrical identification product indicated. SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M Characteristics Pendant control stations, for control circuits Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 XAC-B : standard version : NEMKO, CSA 300 V type 4 Approvals XAC-M : standard

More information

OPERATOR ADAPTER ECHV

OPERATOR ADAPTER ECHV OPERATOR ADAPTER ECHV Installation Instructions for Eaton Cutler-Hammer C361 and C371 Variable Depth Operating Mechanisms (For parts list, see Page 2) Rev. A 2014 Pentair Equipment Protection PH 763 422

More information

5570M Series Intercom Installation and Operation Guide

5570M Series Intercom Installation and Operation Guide 5570M Series Intercom Installation and Operation Guide Isolated balanced/unbalanced lines Audio signals for the 5570M are transmitted over a wire pair using balanced line technology. An isolation transformer,

More information

Control Panel: The Electronic Power Crossfeed System converts

Control Panel: The Electronic Power Crossfeed System converts The Electronic Power Crossfeed System converts the standard Super Duty Saw from manual carriage control to a semi-automatic carriage feed. It is designed to produce the best possible result of cut quality,

More information

Distribution/Substation Transformer

Distribution/Substation Transformer Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

PSOL. Remove mounting screws. Remove ears. Add 6" leads PSOL = #12 AWG solid PSTR = #12 AWG stranded

PSOL. Remove mounting screws. Remove ears. Add 6 leads PSOL = #12 AWG solid PSTR = #12 AWG stranded Switch Options Work Smarter Not Harder Arrow Hart custom configured wiring devices can match any of your complex industrial or commercial job needs, simplifying your project and maximizing your bottom

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

B. Manufacturers: Square-D, G.E. or Westinghosue.

B. Manufacturers: Square-D, G.E. or Westinghosue. SECTION 16470 - PANELBOARDS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights Characteristics 1 Environment Protective treatment Standard version TH Ambient air temperature Storage C - 40 + 70 around the device Operation C - 25 + 70 for LED and neon bulb versions - 25 + 40 for incandescent

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages

More information

VARIABLE FREQUENCY DRIVE SPECIFICATION

VARIABLE FREQUENCY DRIVE SPECIFICATION VARIABLE FREQUENCY DRIVE SPECIFICATION 1.0. SUMMARY The use of variable frequency drives (VFDs) in conjunction with wastewater lift stations has been identified as a means improve efficiency and to moderate

More information

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1, EN50041 UL and C-UL listed T4011 Heavy-duty Metal Body Safety Interlock Switch Rugged enclosure the all metal housing and stainless steel actuator

More information

12ft X 12ft Attached Breeze Pergola Assembly Manual. Outdoor Living Today. (For Both 9 and 12 High Posts) June 1st/2012 Version #4

12ft X 12ft Attached Breeze Pergola Assembly Manual. Outdoor Living Today. (For Both 9 and 12 High Posts) June 1st/2012 Version #4 12ft X 12ft Attached Breeze Pergola Assembly Manual (For Both 9 and 12 High Posts) Outdoor Living Today June 1st/2012 Version #4 Note: Installation of Wall Side Girders (P) and Wall Mount Brackets (M)

More information

OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE

OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE MANUAL AIR MOTOR 04666770 Edition 1 April, 1999 IMPORTANT SAFETY INFORMATION ENCLOSED. READ THIS MANUAL BEFORE OPERATING TOOL. FAILURE TO OBSERVE

More information

Increased safety - Group IIC XAWP series. Glass-reinforced polyester (GRP) -20 C C INERIS03ATEX0122X

Increased safety - Group IIC XAWP series. Glass-reinforced polyester (GRP) -20 C C INERIS03ATEX0122X Pendant stations ncreased safety - Group C XAWP series The pendant stations XAWP are suitable for all types of industry and primarily used on overhead cranes, cranes. They are available with 2, 4, 6 or

More information

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End; 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 1100 1G Mall Box Appleton/Oz Gedney Catalog Number 1100 Manufacturer Appleton/Oz Gedney Description Cast Device Box, Height

More information

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification. Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.

More information

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes 05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes 05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A76 A76 pq^ka^oapi=ommu=k^qflk^i=bib`qof`^i=`lab Δ déåéê~ä=^ééäáå~íáçåë o^`l=ñäççê=äçñéë=~êé=áçé~ääó=ëìáíéç

More information