Electronic timer CT-SDS.22
|
|
- Reynard Floyd
- 5 years ago
- Views:
Transcription
1 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication Width of. mm Sealable transparent cover (optional accessory) for protection against unauthorized changes of time values Integrated marker label a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U/T: green LED V control supply voltage applied W timing Approvals A C D K E Marks a b UL 08, CAN/CSA C. No. GL GOST CB scheme CCC CE C Tick Order data Type Rated control supply voltage Time range Output Order code d R: yellow LED V output relay energized CT-SDS. 8 V DC, 0 V AC 0.0 s 0 min n/o contacts e R: yellow LED V output relay energized f Marker label Order data Accessories Adapter for screw mounting on panel Type Width in mm Order code ADP.0. SVR 0 09 R000 Sealable transparent cover Type Width in mm Order code COV.0. SVR 0 00 R000 Marker label Type Width in mm Order code MAR.0. SVR 07 R000
2 Application The CT S range timers are designed for use in industrial applications. They operate over an universal range of supply voltages and a large time delay range, within compact dimensions. The easy to set front face potentiometers, with direct reading scales, provide accurate time delay adjustment. Operating mode The CT SDS. has n/o contacts and includes separated timing circuits: an adjustable motor starting delay, the time the star contactor is energized, and an 0 ms fixed open transition delay before the delta contactor is energized. A rotary switch, on the front of the unit, allows selection of one of 7 time ranges from 0.0 s 0 min. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit. Timing is displayed by a flashing green LED labelled U/T. Function diagram Remarks Legend: G Control supply voltage not applied / Output contact open B Control supply voltage applied / Output contact closed Terminal designations on the device and in the diagrams: The st n/o contact is designated 7 8. The nd n/o contact is designated 7 8. Control supply voltage is applied to terminals A A. Function of the yellow LEDs: The two yellow LEDs are designated R and R. LED R shows the status of the st n/o contact (7 8) and LED R shows the status of the nd n/o contact (7 8). LED R or R glows as soon as the corresponding output relay energizes and turns off when the corresponding output relay de energizes. F Star delta change over This function requires continuous control supply voltage for timing. Applying control supply voltage to terminals A A, energizes the star contactor connected to terminals 7 8 and begins the set starting time t. The green LED flashes during timing. When the starting time is complete, the first output contact de energizes the star contactor. Now, the fixed transition time t of 0 ms starts. When the transition time is complete, the second output contact energizes the delta contactor connected to terminals 7 8. The delta contactor remains energized as long as control supply voltage is applied to the unit. A-A green LED t t t = adjusted starting time t = transition time (0 ms) CDC 00 F00
3 Examples of application Star delta change over Control circuit diagram L F F S CDC 8 F0b0 S I K KT K K K K N KT A A K A A K A A K A A Y N Star delta change over Power circuit diagram L L L -F CDC 0 F0b07 -K -K -K -F M W V U M ~ W V U Connection diagram A 7 A A A CDC 0 F0b n/o contact 7 8. n/o contact A A Rated control supply voltage U S 8 V DC or 0 V AC
4 Technical data Data at T a = C and rated values, unless otherwise indicated Input circuits - Supply circuit Rated control supply voltage U S A A 8 V DC A A 0 V AC Rated control supply voltage tolerance 8 V DC...+0 % 0 V AC...+0 % Typical current / power consumption V DC 0 V AC V AC Rated frequency Frequency range AC 8 V DC 0 V AC ma / on request / / / 0 ma / on request DC; 0/0 Hz 7 Hz Power failure buffering time V DC min. ms Timing circuit 0 V AC min. 0 ms Kind of timer Single function timer Star delta change over ma / on request Time ranges 0.0 s 0 min 0.0 s, 0. s, 0. 0 s,. 0 s, 00 s, 00 s, 0. 0 min Recovery time < 80 ms Repeat accuracy (constant parameters) Δt <± 0. % Accuracy within the rated control supply voltage tolerance Accuracy within the temperature range Star delta transition time Star delta transition time tolerance Indication of operational states Δt < 0.00 %/V Δt < 0.0 %/ C fixed, 0 ms ± ms Control supply voltage / timing U/T: green LED V: control supply voltage applied Control supply voltage / timing U/T: green LED W: timing Relay status R: yellow LED V: output relay energized Relay status R: yellow LED V: output relay energized Output circuits Kind of output 7 8 Relay,. n/o contact Contact material Rated operational voltage U e Minimum switching voltage / Minimum switching current Maximum switching voltage / Minimum switching current 7 8 Relay,. n/o contact Cd free 0 V V / 0 ma see load limit curves / see load limit curves Rated operational current I e (IEC/EN 097 ) AC (resistive) at 0 V A AC (inductive) at 0 V A DC (resistive) at V DC (inductive) at V A A
5 Output circuits AC rating (UL 08) Mechanical lifetime Electrical lifetime Maximum fuse rating to achieve short-circuit protection (IEC/EN 097 ) Utilization category (Control Circuit Rating Code) max. rated operational voltage max. continuous thermal current at B 00 max. making / breaking apparent power at B 00 n/c contact n/o contact B V AC A 00/0 VA 0 x 0 switching cycles 0. x 0 switching cycles (AC, 0 V, A) A fast acting 0 A fast acting General data Duty time 00 % Dimensions (W x H x D) Weight Mounting position Minimum distance to other units. x 78 x 00 mm (0.89 x.07 x.9 inches) 0.0 kg (0. lb) normal operation mode horizontal none vertical Mounting DIN rail (IECEN 07), snap on mounting without any tool Degree of protection enclosure / terminals IP0 / IP0 any none Electrical connection all circuits Wire size Stripping length Tightening torque fine strand with wire end ferrule fine strand without wire end ferrule Screw connection x 0.7. mm ( x 8 AWG) x 0.7. mm ( x 8 AWG) rigid x 0. mm ( x 0 AWG) 7 mm (0.8 inches) Nm Environmental data Ambient temperature range operation...+0 C storage C Damp heat, cyclic (IEC/EN 008 0) x h cycle, C, 9 % RH Vibration, sinusoidal (IEC/EN 008 ) functioning 0 m/s, 0-8/0-0 Hz resistance 0 m/s, 0-8/0-0 Hz, 0 cycles Vibration, seismic (IEC/EN 008 ) functioning 0 m/s² Shock, half sine (IEC/EN 008 7) functioning 00 m/s, ms, shocks/direction resistance 00 m/s, ms, shocks/direction
6 Isolation data Rated insulation voltage U i output circuit / output circuit 00 V Rated impulse withstand voltage U imp (IEC/EN 0, VDE 00) Power frequency withstand voltage test (test voltage) input circuit / output circuit 00 V between all isolated circuits kv;./0 µs between all isolated circuits routine test:.0 kv; 0 Hz, s type test:. kv; 0 Hz, min Basic insulation (IEC/EN 0) input circuit / output circuit 00 V Protective separation (IEC/EN 0; VDE 00 part 0 and part 0/A) Pollution degree (IEC/EN 0-, VDE 00, UL 08) Overvoltage category (IEC/EN 0-, VDE 00, UL 08) Standards / Directives input circuit / output circuit 0 V III Product standard IEC 8, EN 8 + A, DIN VDE 0 part 0 EMC Directive Low Voltage Directive RoHS Directive Electromagnetic compatibility 00/08/EC 00/9/EC 00/9/EC Interference immunity to IEC/EN 000 IEC/EN 000 electrostatic discharge IEC/EN 000 Level ( kv / 8 kv) radiated, radio-frequency, electromagnetic field IEC/EN 000 Level (0 V/m) electrical fast transient / burst IEC/EN 000 Level ( kv / khz) surge IEC/EN 000 Level ( kv A A) conducted disturbances, induced by radiofrequency fields IEC/EN 000 Level (0 V) harmonics and interharmonics IEC/EN 000 Level Interference emission IEC/EN 000 IEC/EN 000 high-frequency radiated IEC/CISPR, EN 0 Class B high-frequency conducted IEC/CISPR, EN 0 Class B
7 Technical diagrams Load limit curve AC voltage [V] resistive load CDC 9 F00 DC voltage [V] resistive load CDC 0 F00 AC current [A] DC current [A] AC load (resistive) DC load (resistive) Derating factor F Derating factor F CDC F cos ϕ Contact lifetime Switching cycles 0 V resistive load CDC 8 F00 Switching current [A] Dimensions in mm 09,., CDC 88 F0b CT-SDS. 7
8 Dimensions accessories in mm CDC 008 F ADP.0 Adapter for screw mounting on panel.70, ,.8 8, CDC 8 F000 front-to-back size 07 COV.0 Sealable transparent cover A CDC 8 F000 MAR.0 Marker label Synonyms Used expression Alternative expression(s) c/o contacts DPDT / SPDT Further documentation Document titel Document type Document number Electronic Products and Relays Technical catalogue CDC 0 00 C00x CT-APS, CT-ERS, CT-MVS, CT-SDS Instruction manual SVC 0 00 M0000 You can find the documentation on the internet at R Control Products R Electronic Relays and Controls 8
9 Contact us STOTZ-KONTAKT GmbH P. O. Box Heidelberg, Germany Phone: +9 (0) Fax: +9 (0) info.desto@de.abb.com You can find the address of your local sales organisation on the home page -> Low Voltage Products and Systems Document number CDC 09 D00 (0/0) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of AG. Copyright 00 All rights reserved
Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from
More informationElectronic timer CT-MFS.21
2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationElectronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact The CT-MVS.12 is a multifunctional electronic timer from the CT-S range and provides 10 timing functions and 10 time ranges.
More informationCurrent monitoring relays CM-SRS.1 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More informationElectronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationElectronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.22 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.
More informationElectronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.
2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage
More informationElectronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-YDE Star-delta change-over with c/o (SPDT) contact The CT-YDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationCurrent monitoring relays CM-SRS.1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationElectronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MXS.22 is a multifunctional electronic timer from the CT-S range. It provides 5 timing functions, 2 times 10 time
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationThree-phase monitoring relay
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationThree-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-
More informationThree-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
More informationElectronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact
Data sheet Electronic timer CT-SDE Star-delta change-over with n/c + n/o contact The CT-SDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More informationElectronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts The CT-MFS.21 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions, 10 time ranges
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More informationElectronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts The CT-MFS.21 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions, 10 time ranges
More informationElectronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationElectronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.
More informationCurrent monitoring relays CM-SRS.M1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent
More informationThree-phase monitoring relay CM-PBE
Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More informationThree-phase monitoring relays CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is
More informationThree-phase monitoring relay CM-PVE
Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012
More informationLiquid level monitoring relay CM-ENS.2x
Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43 The three-phase monitoring relays CM-MPS.x3 monitor the phase parameters phase sequence, phase failure, over- and
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.23
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 The three-phase monitoring relay CM-MPS.23 monitors the phase parameters phase sequence, phase failure, over- and undervoltage
More informationElectronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact The CT-AHE is an electronic time relay with OFF-delay. t is from the CT-E range. The CT-E range is the economic range of ABB s time
More informationElectronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AWE mpulse-off with auxiliary voltage, 1 c/o (SPDT) contact The CT-AWE is an electronic time relay with mpulse-off function. t is from the CT-E range. The CT-E range is the
More informationMultifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72
Data sheet Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72 The three-phase monitoring relays CM-MPN.x2 monitor the phase parameters phase sequence, phase failure,
More informationPower supply CP-D 12/2.1
2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power
More informationThree-phase monitoring relay
1SR 550 870 F9400 Features Monitoring of three-phase mains for phase failure, over- and undervoltage Device with possibility of neutral monitoring available Device with suitability for monitoring single-phase
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationInsulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC
Data sheet Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN.x serves to monitor insulation resistance in accordance with IEC
More informationElectronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet
1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationPower supply CP-T 48/5.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationPower supply CP-T 24/40.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationElectronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet
2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection
More informationPower supply CP-T 24/10.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationPower supply CP-T 48/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More informationPower supply CP-D 24/1.3
2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power
More informationInsulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC
Data sheet Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 AC The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationInsulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC
Data sheet Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN serves to monitor insulation resistance in accordance with
More informationElectronic timer CT-SDE
CDC 51 059 F000 1 Characteristics " 1 single time range from 0. to 0 s " versions with different supply voltage ranges are available: 4 AC/DC and 110-10 AC and 80-415 AC " Single-function timer with star-delta
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationPower supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer
More informationPower supply CP-E 48/5.0 Primary switch mode power supply Data sheet
2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated
More informationCP-E range Benefits and advantages
Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationInsulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC
Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC
More informationPrimary switch mode power supplies Product group picture
Primary switch mode power supplies Product group picture /1 ABB Catalog Electronic Products and Relays 2015 2CDC 110 004 C0210 Primary switch mode power supplies Table of contents Primary switch mode power
More informationThree-phase monitoring relays Product group picture
Product group picture /7 ABB Catalog Electronic Products and Relays 013/014 CDC 110 004 C009 Table of contents Three-phase monitoring relays Product group picture 7 Table of contents 8 Benefits and advantages,
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More informationInsulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC
Data sheet Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN.1 serves to monitor insulation resistance in accordance with IEC
More informationThree-phase monitoring relays Table of contents
Table of contents Three-phase monitoring relays Three-phase monitoring relays 78 Benefits and advantages, Applications 79 Operating controls 80 Selection table - Singlefunctional 81 Ordering details -
More informationThree-phase monitoring relays Product group picture
Product group picture /7 ABB Catalog Electronic Products and Relays 015 CDC 110 004 C010 Table of contents Three-phase monitoring relays Benefits and advantages, Applications /9 Operating controls /30
More informationAnalog signal converters CC range
Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content
ABB Measuring and monitoring relays CM and C5xx range Content Benefits and advantages, overview of features... 60 Approvals and marks... 64 Current and voltage monitors, single-phase... 65 Ordering details...
More informationControl module CP-A CM
Control module 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP-A RU Adjustable threshold values (14-28 V) and relay outputs per input / channel Approvals Marks g 6 7 1 3 4 2 8 5 Order data
More informationPluggable interface relays CR-U Universal relays
Data sheet Pluggable interface relays CR-U Universal relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC
More informations s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz
HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions
More informationAnalog signal converters CC-E I/I
2CC 281 001 F0b06 Features Loop-powered I/I isolator without external power supply for analog current signals of 0-20 ma and 4-20 ma Electrical isolation between input and output Very low internal voltage
More informationElectronic timers CT-S range Selection and ordering details
CT-S range Selection and ordering details Characteristics CT-S range CT-MFS 1SVR 430 010 F 0200 3 multifunction and 21 multi-range Continuous supply voltage range (24-240VAC/DC) or multisupply voltage
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationLiquid level monitors and controls
Liquid level monitors and controls ontent M-ENE, M-ENE MAX... / 8 M-ENS... / 83 M-ENS UP/DOWN... / 84 M-ENN... / 85 M-ENN UP/DOWN... / 86 Accessories for liquid level relays... / 87 Technical data M-ENE,
More informationATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW
Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW
Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationSubject to changes 11/2003 Page 1/7
Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3
More informationSignal converters Index
Index Power supplies - Signal and data converters General information...1 Analog signal converters....3.26 Features and benefits...3 Application, approvals and marks...4 Overview...5 -.6 Ordering details...7
More information