Power supply CP-T 24/20.0 Primary switch mode power supply

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Power supply CP-T 24/20.0 Primary switch mode power supply"

Transcription

1 Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality, the new range perfectly supplements the existing products and extends the range appropriately. The devices can be supplied with a three-phase voltage as well as with two-phase mains. Here, ABB offers a power supply unit with 24 V DC output with 20 A and efficiency of up to 90 %. As in the case of all products, they are designed for an ambient temperature of up to 70 C. 2CDC S0009 Characteristics Rated output voltage 24 V DC Output voltage adjustable via front-face rotary potentiometer "OUTPUT Adjust" Configurable output behavior (U/I mode, hiccup mode) Rated output current 20 A Rated output power 480 W Wide supply voltage range 3 x V AC ( V AC, V DC) Two-phase supply with a derating of the output to 75 % possible / permitted High efficiency of up to 90 % Low power dissipation and low heating Free convection cooling (no forced cooling with ventilators) Ambient temperature range during operation C Open-circuit, overload and short-circuit stable Integrated input fuse Redundancy unit CP-A RU offering true redundancy, available as accessory Signalling contact "13-14" (solid-state) for output voltage OK Approvals A UL 508, CAN/CSA C22.2 No ) H ANSI/ISA-12.12, CAN/CSA C22.2 No ) (Class I, Div. 2, Hazardous Locations) H UL 60950, CAN/CSA C22.2 No ) U R EAC 1) Approvals refer to rated input voltage U in Marks a CE b RCM Order data Power supply Type Input voltage range Rated output voltage Rated output current Order code CP-T 24/ V AC V DC 24 V DC 20 A 1SVR R0000 Accessory Type Description Order code CP-A RU The redundancy unit CP-A RU provides decoupling of two 24 V DC CP power supply units. 1SVR R0000

2 1 Circuit diagram 2 Output OUTPUT L+, L+, L-, L-: terminals - output 2CDC S Adjustable output voltage OUTPUT Adjust: potentiometer The CP-T range types feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long cable length. 4 Indication of operational states OUTPUT LOW: red LED - output voltage too low OUTPUT OK: green LED - output voltage OK 5 Signalling contact OUTPUT 13-14: terminals - signalling contact 6 Configuration of single or parallel operation Sliding switch 7 Configuration of U/I mode/hiccup mode Sliding switch 8 Wide input range INPUT L1, L2, L3, PE: terminals - input Optimised for worldwide applications: The CP-T power supply units can be supplied for a wide range of AC and DC voltages. Both kinds of power supply (three-phase and two-phase) are possible. Application The primary switch mode power supply offers a three-phase supply voltage range of 3 x V AC. A two-phase power supply is also possible and it can also be supplied by V DC. Furthermore, this power supply unit is equipped with two generous capacitors, which ensure mains buffering of at least 20 ms. That is why the devices can be used worldwide also in high fluctuating networks and battery-powered plants. Operating mode By means of the potentiometer "OUTPUT Adjust" the output voltage can be adjusted within a range of V DC. Thus, the power supply can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. The green LED "OUTPUT OK" is lightening during proper operation, i. e. when the output voltage exceeds 75 %. The red LED "OUTPUT LOW" is lightening when the output voltage is less than 70 % of the rated output voltage. Two-phase supply is permissible with a derating of the output to 75 %. Signalling contact "13-14" (max. 60 V DC / 0.3 A) is ON when the output voltage exceeds 19.4 V. 2 - Power supply CP-T 24/20.0 Data sheet

3 L2 L3 PWM L+ Installation The device must be installed by qualified persons only and in accordance with the specific national regulations (e.g. VDE, etc.). The devices are maintenance-free chassis-mounted units. Before installation Mounting DANGER! Components with high stored energy and circuits with high voltage Danger to be electrocuted! Disconnect the system from the supply network and protect against switching on before any installation, maintenance or modification work. Do not introduce any objects into the unit and do not open the unit. Ensure that the service personnel is protected against inadvertent contact with parts carrying energy. The switch mode power supply can be snapped on a DIN rail (TH or TH according to IEC/EN 60715) as shown in the accompanying picture. For that the device is set with its mounting rail slide on the upper edge of the mounting rail and locked by lifting it downwards. 2CDC F0010 Demounting Remove the switch mode power supply as shown in the accompanying picture. For that the latching lever is pulled downwards by means of the screwdriver. Alternatively you can press the unlock button to release the device. Then in both cases the device can be unhinged from the mounting rail edge and removed. 2CDC F0010 Mounting position The devices have to be mounted horizontally with the input terminals on the bottom. In order to ensure a sufficient convection, the minimum distance to other modules should not be less than 25 mm (0.98 in) in vertical and horizontal direction. [A] [B] L1 CP-T 24/20.0 L+ L- L- L1 L2 L3 L+ L+ L- L- [B] [A] 2CDC F0010 Data sheet Power supply CP-T 24/20.0-3

4 Electrical connection L+ L+ L- L- L1 L2 L3 o PWM L+ L+ L- L- o L1 L2 L3 Connection diagram 2CDC F0010 L+, L- Output voltage L1, L2, L3 Input voltage Signalling contact o Protective earth Preparations: Connect to main according to the specific national regulations. Power supply cables and unit must be sufficiently fused. A disconnecting device has to be provided for the power supply to disengage unit and supply cables from supply mains if required. We recommend to choose the cable section as large as possible in order to minimize voltage drops. In order to ensure sufficient air-cooling the distance to other devices has to be considered. Instructions: 1. Connect the input terminals L1, L2 and L3. 2. Connect the protective earth conductor to the terminal o (protection class I). 3. Provide a suitable disconnecting device (e.g. line protection switch) in the supply line acc. to IEC/EN Rate the lines for the maximum output current (considering the short-circuit current) or provide a separate fuse protection. The input side is protected by an internal input fuse. 5. Observe the polarity. The device is overload, short-circuit and open-circuit proof. The secondary side of the power supply unit is electrically isolated from the input and internally not earthed (SELV) and can therefore be earthed by the user according to the needs with L+ or L- (PELV). Operation DANGER! High current Risk of electric arcs and electric shocks! Do not modify the installation (primary and secondary side). Intended use. CAUTION! Depending on the operation conditions the enclosure can become very hot Risk of burns! In order to ensure sufficient air-cooling the distance to other devices has to be considered. The device is intended for use as a primary switch mode power supply. Any other usage is not supported by the manufacturer. Other usage may impair safety and cause operational difficulties or destruction of the unit. Service The internal fuse is not user-replaceable. If the internal fuse blows, most probably the device is defective. In this case, an examination of the switch mode power supply by the manufacturer is necessary. 4 - Power supply CP-T 24/20.0 Data sheet

5 Technical data Data at T a = 25 C, U in = 3 x 400 V AC and rated values, unless otherwise indicated Input circuit - supply circuit L1, L2, L3 Rated input voltage U in 3 x V AC Input voltage range V AC V DC Frequency range AC Hz Typical input current 1.1 A Typical power consumption 538 W Inrush current limiting 20 A Power failure buffering time min. 20 ms Internal input fuse per phase T3.15 A / 500 V AC Recommended backup fuse 3 pole miniature circuit breaker ABB type S 203 characteristic B or C max. rating 20 A Power factor correction (PFC) yes, passive, 0.65 Discharge current towards PE < 3.5 ma input / output < 0.25 ma Indication of operational states Output voltage OUTPUT OK: green LED output voltage OK OUTPUT LOW: red LED output voltage too low Output circuit L+, L+, L-, L- Rated output power 480 W Rated output voltage 24 V DC Tolerance of the output voltage % Adjustment range of the output voltage V DC Rated output current I r T a 60 C 20 A Derating of the output current 60 C < T a 70 C 2.5 %/ C Signalling contact for output voltage OK solid-state (max. 60 V DC, 0.3 A) threshold V insulation voltage 500 V DC Mininum fuse rating to achieve short-circuit M 60 V DC, m 0.3 A fast-acting protection Maximum deviation with load change statical ±1 % (single mode) ±5 % (parallel mode) change of output voltage within ±0.5 % the input voltage range Control time at rated load < 2 ms Starting time after applying the supply voltage at I r max. 1 s with 7000 µf max. 1.5 s Rise time at rated load max. 150 ms with 7000 µf max. 500 ms Fall time max. 150 ms Residual ripple and switching peaks BW = 20 MHz 100 mv Parallel connection configurable, to increase power, up to 2 devices, Series connection min. 0.1 I r - max. 0.9 I r yes, to increase voltage, max. 2 devices Data sheet Power supply CP-T 24/20.0-5

6 Output circuit - no-load, overload and short-circuit behaviour Characteristic curve of output U/I or hiccup mode, configurable Short-circuit protection continuous short-circuit proof Short-circuit behaviour current limiting Resistance to reverse feed approx. 35 V Overload protection hiccup mode No-load protection continuous no-load stability Overtemperature protection yes, automatic recovery after temperature went down Starting of capacitive loads 7000 µf General data Efficiency typ. 90 % Duty time 100 % Dimensions of housing (W x H x D) 150 x 124 x mm (5.91 x 4.88 x 4.68 in) Weight kg (3.653 lb) Material of housing metal Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection housing / terminals IP20 / IP20 Protection class I Electrical connection - input circuit L1, L2, L3 Connecting capacity fine-strand with wire end ferrule mm² (24-11 AWG) fine-strand without wire end ferrule mm² (24-10 AWG) rigid mm² (24-10 AWG) Stripping length 8 mm (0.31 in) Tightening torque 1 Nm (9 lb.in) Electrical connection - output circuit L+, L+, L-, L- Connecting capacity fine-strand with wire end ferrule mm² (24-11 AWG) fine-strand without wire end ferrule mm² (24-10 AWG) rigid mm² (24-10 AWG) Stripping length 8 mm (0.31 in) Tightening torque 0.6 Nm (5.5 lb.in) Electrical connection - signalling circuit 13, 14 Connecting capacity fine-strand with wire end ferrule mm² (24-22 AWG) fine-strand without wire end ferrule -- rigid mm² (26-20 AWG) Stripping length 8 mm (0.31 in) Tightening torque n/a (spring-type terminals) 6 - Power supply CP-T 24/20.0 Data sheet

7 Environmental data Ambient temperature range operation C ( F) rated load C ( F) storage C ( F) Altitude during operation (IEC/EN ) max m Damp heat, cyclic IEC/EN % without condensation Vibration, sinusoidal IEC/EN g, Hz, 2G, each along X, Y, Z axes 60 min / cycle Shock, half-sine IEC/EN g, 11 ms, 3 axes, 6 faces, 3 times for each face Isolation data Rated insulation voltage U i input circuit / output circuit 3 kv AC input / PE 1.5 kv AC output / PE 0.5 kv AC; 0.71 kv DC signalling contact / PE 0.5 kv DC Pollution degree 2 Overvoltage category II Standards / Directives Standards IEC/EN Low Voltage Directive 2014/35/EU Protective low voltage SELV (IEC/EN ) EMC Directive 2014/30/EU RoHS Directive 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN electrostatic discharge IEC/EN level 4 (air discharge 15 kv / contact discharge 8 kv) radiated, radio-frequency, electromagnetic IEC/EN level 3 (10 V/m) field electrical fast transient/burst IEC/EN level 4 (4 kv / 5 khz) surge IEC/EN L-L level 3 (2 kv) / L-PE level 4 (4 kv) conducted disturbances, induced by radiofrequency IEC/EN level 3 (10 V) fields power frequency magnetic fields IEC/EN level 4 (30 A/m) voltage dips, short interruptions and voltage variations IEC/EN dips: >95 % 0.5 ms / >30 % 25 ms interruptions: >95 % 250 ms Interference emission IEC/EN high-frequency radiated IEC/CISPR 22, EN class B high-frequency conducted IEC/CISPR 22, EN class B limits for harmonic current emissions IEC/EN class A Data sheet Power supply CP-T 24/20.0-7

8 Technical diagrams Output behaviour U out in V 28 3 x 400 V 3 x 500 V supply I out in A 2CDC F0009 Characteristic curve of output at T a = 25 C U out in V 28 3 x 400 V 3 x 500 V supply Hiccup mode I out in A 2CDC F0009 Hiccup mode, characteristic curve of output at T a = 25 C The switch mode power supply CP-T 24/20.0 is able to supply at 24 V DC output voltage and at an ambient temperature of: 60 C a continuous output current of approx. 20 A at ambient temperatures of: 60 C < T a 70 C the output power has to be reduced by 2.5 % per C temperature increase. If the switch mode power supply is loaded with an output current > 20 A, the operating point is passing through the U/I characteristic curve shown. Temperature behaviour P out [%] T a [ C] 2CDC F0211 Characteristic curve of temperature at rated load 8 - Power supply CP-T 24/20.0 Data sheet

9 Dimensions in mm and inches CDC F Power supply CDC F0007 Accessory redundancy unit CP-A RU Data sheet Power supply CP-T 24/20.0-9

10 Further documentation Document title Document type Document number Electronic products and relays Technical catalogue 2CDC C02xx Power supply units Application manual 2CDC M020x Redundancy unit CP-A RU Data sheet 2CDC D0202 You can find the documentation on the internet at -> Automation, control and protection -> Power supplies. CAD system files You can find the CAD files for CAD systems at -> Low Voltage Products & Systems -> Control Products -> Power Supplies Power supply CP-T 24/20.0 Data sheet

11 Contact us ABB STOTZ-KONTAKT GmbH P. O. Box Heidelberg, Germany Phone: +49 (0) Fax: +49 (0) You can find the address of your local sales organisation on the ABB home page -> Low Voltage Products and Systems Document number 2CDC D0201 (08/2016) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2016 ABB All rights reserved

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

CP-E range Benefits and advantages

CP-E range Benefits and advantages Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact The CT-AHE is an electronic time relay with OFF-delay. t is from the CT-E range. The CT-E range is the economic range of ABB s time

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MXS.22 is a multifunctional electronic timer from the CT-S range. It provides 5 timing functions, 2 times 10 time

More information

Three-phase monitoring relay

Three-phase monitoring relay 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.

More information

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC Data sheet Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 AC The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.22 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply Data sheet Power supply 24/10.0 Product revision M F High-performance primary switch mode power supply The power supplies are ABB s highperformance and most advanced range. With excellent efficiency, high

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

Control module CP-A CM

Control module CP-A CM Control module 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP-A RU Adjustable threshold values (14-28 V) and relay outputs per input / channel Approvals Marks g 6 7 1 3 4 2 8 5 Order data

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC Data sheet Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN.1 serves to monitor insulation resistance in accordance with IEC

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

Three-phase monitoring relay

Three-phase monitoring relay 1SR 550 870 F9400 Features Monitoring of three-phase mains for phase failure, over- and undervoltage Device with possibility of neutral monitoring available Device with suitability for monitoring single-phase

More information

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 1AC/24DC/20 Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet 2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection

More information

Analog signal converters CC range

Analog signal converters CC range Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally

More information

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features Uninterruptible power supply Data sheet 105623_en_00 PHOENIX CTACT 2013-06-07 1 Description Uninterruptible power supply units continue to deliver power even in the event of mains breakdowns or failures.

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis

More information

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals

More information

Electronic timer CT-SDE

Electronic timer CT-SDE CDC 51 059 F000 1 Characteristics " 1 single time range from 0. to 0 s " versions with different supply voltage ranges are available: 4 AC/DC and 110-10 AC and 80-415 AC " Single-function timer with star-delta

More information

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys TSX Series Modicon Manuals Presented by: Modicon PLC Schneider Electric Quantum Modicon Gould Gettys For Product Needs: Email: sales@modiconplc.com Call: 1-800-691-8511 Fax: 919-415-1614 ModiconPLC.com

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21 Data sheet Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21 The CM-UFD.M21 is a multifunctional grid feeding monitoring relay for three-phase mains. It provides different monitoring functions

More information

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet IMA 400 Watts Power Supply Series for medical and industrial applications Product data sheet 400 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Type: DILM40(RDC24) Article No.:

Type: DILM40(RDC24) Article No.: Type: DILM40(RDC24) Article No.: 277780 Ordering information Rated operational current AC 3 400 V I e A 40 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

02/11/2015

02/11/2015 "Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue

More information

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT - 09/2009 Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits

More information

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max. TMT Series, 10 to 50 Watt Features Ultra compact, fully encapsulated plastic case Single-, dual- and triple output models 2 package styles: - with screw terminal block for chassis mount - with solder pins

More information

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet IMA 600 Watts Power Supply Series for medical and industrial applications Product datasheet 600 Watts Power Supply Series for medical and industrial applications Features Safety rated for Medical, Industrial

More information

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter Features Regulated Converter Description Wide input range 85-35Vac Full load temperature range: -4 C to +65 C Ultra-high efficiency over entire load range No external components necessary International

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

02/11/2015

02/11/2015 Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions

More information

em4 local - Robust Specific characteristics Part number

em4 local - Robust Specific characteristics Part number em4 em4 local em4 local Very compact and easy to program nanoplc Save time in designing your application using the most intuitive graphical function block language of the market Measure accurately your

More information

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet IMA 1000 Watts Power Supply Series for medical and industrial applications Product data sheet Features 1000 Watts Power Supply Series for medical and industrial applications Safety rated for Medical, Industrial

More information

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS 4 Power Supplies SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility

More information

MB120S 120W Single Output Medical Series

MB120S 120W Single Output Medical Series Features 2 x 4 x 1.25 Package, Ideal for 1U Applications 10-year Life design with Premium E-Caps 100 Watts convection cooled Class B Conducted and Radiated EMI performance BF Isolation Type Rated Designed

More information

Liquid level monitors and controls

Liquid level monitors and controls Liquid level monitors and controls ontent M-ENE, M-ENE MAX... / 8 M-ENS... / 83 M-ENS UP/DOWN... / 84 M-ENN... / 85 M-ENN UP/DOWN... / 86 Accessories for liquid level relays... / 87 Technical data M-ENE,

More information

LB115S 115W Single Output

LB115S 115W Single Output Features Small size of 2 x 4 x 1.3 75W convection cooled/115 Watts with 200 LFM Universal Input 90-264Vac Meets EN55015 Conducted EMI Meets IEC61000-3-2 Class C for less than 1 Watt to full power Approved

More information

Doc. EA Model Number:

Doc. EA Model Number: VPS-030AAC Series / VPS-030AAC 030AAC Highlights & Features VPS-030AAC05, 12, 15, 24 Meet DOE Level VI & ErP 2017 Low touch current. Suitable for type BF applications Detachable AC plug with multiple country

More information

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter Features Regulated Converter Description 5W Class II power supply in compact 1 x 1 Package (high power density) Internal EMC class B filter UL/IEC/EN695-1 certified UL/IEC/EN62368-1 certified Electrical

More information

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8. HIGH DENSITY, CONFIGURABLE AC-DC POWER SUPPLY RCB1200 SERIES DS_RCB1200_RE04_OCTOBER 2015 DESCRIPTION The RCB1200 is a modular, configurable power supplies that provide high performance and outstanding

More information

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928 Safety Technique safemaster Emergency Stop Module With Time Delay BH 5928, BI 5928 0226419 BH 5928 BI 5928 Function Diagram According to - Performance Level (PL) e and category 4 to E ISO 13849-1 2008

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

02/11/2015

02/11/2015 17.5 mm - 1 Relay 5A EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer

More information

Industrial Applications Telecom Daracom

Industrial Applications Telecom Daracom ABC200 Series is a family of compact and efficient AC-DC power supplies suited for telecom datacom and many other industrial applications. This family meets the international information technology safety

More information

Semiconductor contactors, Solid-state relays

Semiconductor contactors, Solid-state relays Semiconductor contactors, Solid-state relays Content Benefits and advantages... 338 Approvals and marks... 338 Semiconductor contactors... 339 Ordering details... 339 R100.xx, single-phase... 339 R300.xx,

More information

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW) Passive Current Transducers for Sinusoidal Alternate Currents From 0... A/0...5 A (-SW) Passive current transducer without power supply Measuring range A and 5 A AC, reconnectable Available with threshold

More information

Datasheet. PRO-M Series Power Supplies

Datasheet. PRO-M Series Power Supplies Datasheet PRO-M Series Power Supplies N E W These compact and efficient power supplies are optimized for machinery, with features that include overload resistance and high performance reserves. They also

More information

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI and EU CoC Tier 2 Requirements No load input power Average Efficiency Up to 60W of AC-DC Power Universal Input 90-264Vac Input Range Meets Heavy Industrial Levels

More information

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications HEC130/150RTN48QSCA A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case with

More information

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type: DILEM 10(220V50HZ,240V60HZ) Article No.: Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

05/09/2012

05/09/2012 17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option

More information

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B AC switching Solid State Relay Switching through back to back thyristors Long

More information

HEC-100RTA-48QSCA Rev A1.0

HEC-100RTA-48QSCA Rev A1.0 HEC100RTA48QSCA Rev A1.0 A. Features High Efficiency (Up to 90%). Active Power Factor Correction (Typical 0.96). Isolation Class I (With FG) AllRound Protection: OVP/SCP/OTP/OPP. Fully isolated Metal case

More information

QS20.241, QS A1, QS C1

QS20.241, QS A1, QS C1 POWER SUPPLY AC 100-240V Wide-range Input Width only 82mm Efficiency up to 93.9% ATEX and IECEx Approved (-A1 Version) -C1 Version with Conformal Coated PC-board 150% (720W) Peak Load Capability Safe Hiccup

More information

HEC-45LTN-45PFAS Rev A

HEC-45LTN-45PFAS Rev A A. Features High Efficiency (Up to 85%). Active Power Factor Correction (Typical 0.96). Isolation Class II. All-Round Protection: OVP/SCP/OPP. Fully isolated plastic case with IP20 and dry location. Class

More information

For non-electrical quantities

For non-electrical quantities Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data

More information

TE W Single Output External Power Test & Measurement/Industrial Series

TE W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 120W of AC-DC Power Universal Input 90-264Vac Input Range IPX-2 Rated Enclosure for protection against liquid

More information

REX12 Electronic Circuit Protector

REX12 Electronic Circuit Protector Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double

More information

Type: DILEM 10 G(24VDC) Article No.:

Type: DILEM 10 G(24VDC) Article No.: Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220

More information

General. Environmental. EMC & Safety

General. Environmental. EMC & Safety AC-DC 400-2500 Watts f lexpower Series Configurable for Fast Time to Market SEMI F47 Compliant xppower.com Flexible Series & Parallel Capability -20 C Operation Extra Power Available at High Line Optional

More information

LED Driver Constant voltage

LED Driver Constant voltage Driver LCU 100/96W 12/24V IP20 EXC EXCITE indoor IP20 series Product description LED Driver Universal input voltage range Constant output voltage Push terminals for simple wiring Nominal life-time up to

More information

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features LPS Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 20W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets Heavy

More information

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928 Safety Technique SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928 0226419 BH 5928 BI 5928 Function Diagram According to - Performance Level (PL) e and category 4 to E ISO 13849-1 2008

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

HEC-30/35LTA-33TDAA Rev A

HEC-30/35LTA-33TDAA Rev A A. Features High Efficiency (Up to 86%). Active Power Factor Correction (Typical 0.95). Isolation Class II All-Round Protection: OVP/SCP/OTP/OPP. Fully isolated metal case with IP20 and dry location. 1-10V,

More information

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

MVAB120 Series 120W 2 x 4 AC-DC Power Supply Converter www.murata-ps.com MVAB120 Series FEATURES ITE (2nd) and Medical 3rd ed. 1MOPP (primarysecondary) safety approved 120W compact high density 2" x 4" standard footprint High effi ciency up to 91% Universal

More information