Project by: Dr. Jorge A. Diaz. Physics School, University of Costa Rica, National Center for High Technology (CENAT)

Size: px
Start display at page:

Download "Project by: Dr. Jorge A. Diaz. Physics School, University of Costa Rica, National Center for High Technology (CENAT)"

Transcription

1 Test of a Miniature Double-Focusing Mass Spectrometer for the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) at the Advanced Space Propulsion Laboratory Project by: Dr. Jorge A. Diaz Physics School, University of Costa Rica, National Center for High Technology (CENAT) In Conjunction with: Dr. Franklin Chang Diaz Astronaut and Director. Advance Space Propulsion Laboratory (ASPL). NASA-JSC Collaboration: Jared P. Squire, Verlin Jacobson, Greg McCaskill, Andres E. Mora a Vargas. (ASPL-NASA NASA-JSC) Henry Rohrs, Rajiv Chhatwal (Mass Sensors Inc.) A.M.G.D.

2 The Application: What is VASIMR? Next Generation of Rocket Technology to make possible Interplanetary Human Travel Name: VAriable Specific Impulse Magneto-plasma Rocket Uses high temperature plasma confined by electro- magnetic fields that can be modulated to produce variable specific impulse Test of concepts are done at ASPL with the VX-10 chamber Target: MARS by Proof of concept: VX-10. Flight Demonstration VF-10 and prototype at ISS

3 VASIMIR CONCEPT Video: BEKUO STARSHIP using three VASIMR engines

4 Plasma Nozzle Plasma Generation Test Bench on Earth: VX-10

5 VX-10 Experiment at ASPL Probes Superconductive Magnets To Vacuum Chamber Antenna ICRH Plasma Flux Helicon Antenna Gas Inlet

6 Why This Project? Miniature Mass Spectrometer developed at UMN (CDFMS prototype) Distributed Residual Gas Analysis Prototype tested at NASA s Hazardous Gas Detection Lab (Kennedy Space Center) Visit to Houston and conversations with Dr. Franklin Chang Diaz about possible collaboration Provided novel usage of commercial alpha and beta units in harsh environment applications VASIMR VX-10 Test Chamber at NASA s Advanced Space Propulsion Lab VASIMR Test Chamber No residual gas detection capabilities at that point Interest of monitoring ion species ( H2, D2, He, Xe, Ar, ) CDFMS Core

7 Substrate 2 cm Detector The MMS Project at UMN Analyzer Research Goal: To develop a novel miniature mass spectrometer suitable for in situ environmental and harsh environment (e.g. volcanic gaseous emissions) Specific Objective: Substrate Ion Source 2.5 cm Compact Double Focusing Mass Spectrometer (CDFMS) Concept Design and construction of proof of concept miniature mass spectrometer prototype: Compatible with mass production manufacturing techniques Low cost (in large quantities) Portable

8 CDFMS Mass Analyzer: Theory It is based on the mass separation capabilities of sector field analyzers l o mv O Ion Beam Trajectory mv = qv φ = V - V + Mass Selection r o F = qbv qe = F m m = F e B 90 o Cylindrical ExB Sector Field Analyzer c o V l i mv r 2 Single Focusing Direction Focusing (angular spread) MAGNETIC SECTOR Energy Focusing (energy spread) ELECTROSTATIC SECTOR Double Focusing (DF) Ion beam is focused both in direction and energy Higher Resolving Power Usually achieved by analyzers placed in tandem Nier, Mattauch-Herzog MS Crossed ExB DF Analyzer Superimposed elec. & magnetic fields Compact Assembly dr dv = Bv 2E Bv E r v = 0 F F m e = 2 DF Condition

9 CDFMS Ion Simulation SIMION 3D Tuned for Mass 28 Ionization from -1 to 1 mm in z Ion Source Mass 27 amu Mass 28 amu Mass 29 amu

10 Microfabricated Mass Analyzer Electric Fringing Field Correcting Electrodes 0.1 mm Cu V 1 V 2 V 3 V 4 V 5 V 6 V 7 V 8 V 9 2 mm Inner Electrode V + V 1 V 2 V 3 V 4 V 5 V 6 V 7 V 8 V 9 OuterElectro de V Electric Field Correction - vias Fringing field correcting electrodes r = 2mm Ceramic Plates with Correcting Electrodes Copper Cylindrical Electrodes h = 2.5mm Mass Analyzer Cross Section Resistor network

11 Instrument Tested at ASPL Alpha Version of the Integrated Leak Detector (Acronym: α-ild 50) Novel Miniature Mass Spectrometer Instrument based on CDFMS prototype (Patent Application. Licensed by UMN to Mass Sensors) Designed for low cost batch manufacturing Basic element (OEM) for a Field Portable MS Distributed sensing. Internet protocol ILD 50 Specs: Analyzer : 8 mm ExB Double-Focusing Magnetic Sector Mass Spect. Mass Range: amu M/ M: 40 Operating pressure: 10-4 Weight: 153g Size: 40H x 52L x 32W (mm) Remote control through: Internet or wireless Alpha-ILD 50 on KF50 flange

12 KF50 Flange Detector Electrical Connections Ion Source NdFEB 1 T Magnet ExB Analyzer Integrated Leak Detector (α-ild( 50)

13 MMS-VASIMR Project Phase I. August 2001 Main Objectives Provide residual gas analysis and single ion monitoring capabilities to the VASIMR VX-10 test chamber at the ASPL. Test at ASPL new commercial alpha and beta version of the ILD-50 If successful, one possible configuration is to integrate this MMS to the VASIMR main control system to provide feedback information of the rocket in order to manage the amount of mixture that is being injected to the plasma to minimize hot neutrals and enhance performance.

14 Activities MMS-VASIMR Project Phase I. August week visit of Dr. Diaz to ASPL (August, 2001) Installation of alpha unit provided by Mass Sensors Inc at one of the ports of the VASIMR VX-10 test chamber Analyze residual gas concentrations Establish time monitoring of specific ion concentrations both at steady state and while beam is being fired Evaluate high pressure operation of MMS and optimize sensor components to achieve operability at 10 mtorr Optimize hardware and software for user friendly operation

15 Experimental Set-up Single Point Sampling Scheme VX-10 Test Chamber Sampling point KF40 port End wall of VX-10 chamber IDL 50 on KF50 flange KF50 T VX-10 Test Chamber KF40 T KF40 to View port KF50 adapter 90 o tree to avoid high energetic ions from reaching ILD 50 analyzer Gate valve KF40 T Micro Ion Gauge Needle valve Calibration gas KF40 to KF25 adapte

16 Experimental Set-up Electronics and Data acquisition

17 Experimental Set-up Data Collection

18 Propellant Gas Analysis 1.00E E-09 RESIDUAL GAS TEST ILD50 Beta 1 Lab Air with D2 and Ar (6 spect. Avg.) MicroScale DF Mass Spectrometer r = 8 mm Advanced Space Propulsion Lab - JSC/NASA 8/29/01 N2+ Ar+ 8.00E-09 D E E-09 I + (A) 5.00E E E-09 HD+ H2O+ O E-09 Ar E-09 H2+ N E m/z (Da)

19 Residual Gas Analysis VX-10 RGA Turbo, Cryogenic and Diffusion Pumping ASPL -NASA Test 08/30/ E-10 7.E-10 H2O+ N2+ O2+ Hydrocarbon Clusters 6.E-10 CO2+ I+ (A) 5.E-10 4.E-10 P = 9.2e-6 torr 3.E-10 2.E-10 H2+ 1.E-10 0.E+00 C M/Z (Da)

20 VASIMR Plasma Rocket being fired at VX-10 chamber. ASPL-JSC/NASA

21 VX-10 Residual Gas + He pulse. No plasma a-ild 50 Test at ASPL - JSC/NASA 08/30/ E E E-09 He + H2O+ I+ (A) 6.00E E E E M/Z (Da)

22 10 Plasma Monitoring at VX-10. Unit: α-ild 50, Propellant: He Single Ion Monitoring Mode. a-ild 50 Test at VX-10 ASPL-JSC-NASA 9 8 Plasma Generation Plasma Stopped 7 6 Arb units Propellant Injection (He) Time (sec)

23 RESIDUAL GAS TEST ILD50 Beta 1 90% D2 / 10% H2 Bottle MicroScale DF Mass Spectrometer r = 8 mm Advanced Space Propulsion Lab - JSC/NASA 8/29/ E-08 D E E-09 I + (A) 7.00E E E E-09 RP exp ~ 38 RP theory ~ E-09 HD+ 2.00E E-09 H E m/z (Da)

24 CONCLUSIONS and FUTURE WORK The α-ild 50 unit was installed at VASIMR VX-10 test chamber for residual gas analysis and single ion monitoring The theoretical RP (40) was almost achieved over the mass range The designed Mass Range (1-50 Da) ) was verified. Capable of higher mass range with decreased performance Problems: Electronics was not reliable and ion signal to noise problems. p Not good sensitivity. But it is not necessary for this particular r application. New β-ild 50 units are being tested at: KSC in collaboration with the Hazardous Gas Detection Lab. (Dec 2001 and May 2002) University of Costa Rica for volcanic monitoring ASPL on the 2nd phase of the MMS-VASIMR proj. Portable ILD 50 system for 8 months unattended He monitoring at Mammoth Lakes, CA (Aug 2002) New CDFMS based units : 5mm EXB sector for He, H2 leak detection (Mass Sensors Inc.) 30mm ExB sector for high mass range (300 amu) and high sensitivity (ppm( ppm) ) gas analysis (Mass Sensors Inc.) TOTALLY MICROFABRICATED MASS SPECTROMETER (J. Diaz)

Characterization of Common Electron Multipliers in Harsh Environments

Characterization of Common Electron Multipliers in Harsh Environments ELECTRO-OPTICS Characterization of Common Electron Multipliers in Harsh Environments The Pittsburgh Conference 2005 Poster Paper 1340-20 Bruce Laprade and Raymond Cochran BURLE Electro-Optics INC Introduction

More information

Development of a Small Residual Gas Analyzer Utilizing the Quadrupole Array Structure Micropole System ~ QL Series ~

Development of a Small Residual Gas Analyzer Utilizing the Quadrupole Array Structure Micropole System ~ QL Series ~ F e a t u r e A r t i c l e Feature Article Development of a Small Residual Gas Analyzer Utilizing the Quadrupole Array Structure Micropole System ~ QL Series ~ Hirokazu Kitaura The Micropole System is

More information

835 Vacuum Quality Monitor (VQM TM ) 2012 Brooks Automation, Inc. Proprietary Information

835 Vacuum Quality Monitor (VQM TM ) 2012 Brooks Automation, Inc. Proprietary Information 835 Vacuum Quality Monitor (VQM TM ) 2012 Brooks Automation, Inc. Proprietary Information The Revolutionary New Vacuum Quality Monitor World s Fastest, Accurate at low mass Single Gas Calibration Small

More information

Performance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer

Performance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer Performance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer MKS Spectra Products, January 2010 Design considerations for RGA components

More information

Ad Astra Rocket Company. Ad Astra Rocket Company. R&D Support Services

Ad Astra Rocket Company. Ad Astra Rocket Company. R&D Support Services R&D Support Services Ad Astra R&D Support Services Located in Webster, Texas and Liberia, Costa Rica. Ad Astra employs a team of PhD scientists, engineers and technicians skilled in the design, fabrication

More information

Autoresonant Trap Mass Spectrometry

Autoresonant Trap Mass Spectrometry 8 th Harsh Environment Mass Spectrometry Wokshop Autoresonant Trap Mass Spectrometry (ART MS) Sept 21, 2011 Gerardo A. Brucker and G. Jeffery Rathbone Granville-Phillips Vacuum Instrumentation Brooks Automation,

More information

830 Vacuum Quality Monitor

830 Vacuum Quality Monitor Granville-Phillips Vacuum Instrumentation 830 Vacuum Quality Monitor Featuring ART MS Technology February 2011 1 What is ART MS? ART MS Anharmonic Resonant Trap Mass Spectrometry or Auto Resonant Ion Trap

More information

Residual Gas Analyzers XT Series

Residual Gas Analyzers XT Series Residual Gas Analyzers XT Series Products from ExTorr Inc. - Pirani, Ion Gauge, Quadrupole - All Included The Extorr XT residual gas analyzer is a quadrupole mass spectrometer complete with a built-in

More information

The Development of Miniature Electron Multipliers for Use In Portable Mass Spectrometers

The Development of Miniature Electron Multipliers for Use In Portable Mass Spectrometers The Development of Miniature Electron Multipliers for Use In Portable Mass Spectrometers *Bruce N. Laprade, Lenny Erickson William G. Dunn and Reginald Farr BURLE Electro-Optics Sturbridge MA Paper 10400-2100

More information

Enable Highly-Stable Plasma Operations at High Pressures with the Right RPS Solution

Enable Highly-Stable Plasma Operations at High Pressures with the Right RPS Solution Enable Highly-Stable Plasma Operations at High Pressures with the Right RPS Solution Created by Advanced Energy Industries, Inc., Fort Collins, CO Abstract Conventional applications for remote plasma sources

More information

OPTICAL EMISSION CHARACTERISTICS OF HELIUM BREAKDOWN AT PARTIAL VACUUM FOR POINT TO PLANE GEOMETRY

OPTICAL EMISSION CHARACTERISTICS OF HELIUM BREAKDOWN AT PARTIAL VACUUM FOR POINT TO PLANE GEOMETRY OPTICAL EMISSION CHARACTERISTICS OF HELIUM BREAKDOWN AT PARTIAL VACUUM FOR POINT TO PLANE GEOMETRY K. Koppisetty ξ, H. Kirkici 1, D. L. Schweickart 2 1 Auburn University, Auburn, Alabama 36849, USA, 2

More information

Then the mass spectrometer should go to the field, in your hand, small as possible, light as possible, and operated with light battery.

Then the mass spectrometer should go to the field, in your hand, small as possible, light as possible, and operated with light battery. My name is Mo Yang from Korea Basic Science Institute. Everybody here knows that a mass spectrometer is the most powerful analytical tool in chemistry. However, the target samples you want to analyze are

More information

BioInstrumentation Laboratory

BioInstrumentation Laboratory BioInstrumentation Laboratory Ian Hunter Vienna, May 22 2013 BioInstrumentation Lab, Mechanical Engineering, MIT - Robotic endoscopes - Needle-free drug delivery devices - Eye micro-surgery robots - High

More information

The Development of a Novel Electron Multiplier with an Onboard Integral High Voltage Power Supply for use in Mass Spectrometers

The Development of a Novel Electron Multiplier with an Onboard Integral High Voltage Power Supply for use in Mass Spectrometers The Development of a Novel Electron Multiplier with an Onboard Integral High Voltage Power Supply for use in Mass Spectrometers Presented ASMS 2007 New Instrumentation Concepts Session, Poster 043 Bruce

More information

HPR-30 Vacuum Process Gas Analyser A differentially pumped RGA system for vacuum process monitoring

HPR-30 Vacuum Process Gas Analyser A differentially pumped RGA system for vacuum process monitoring HPR-30 Vacuum Process Gas Analyser A differentially pumped RGA system for vacuum process monitoring HPR-30 vacuum process gas analyser To analyse processes with high dynamic range operating at pressures

More information

Micro Analytical Instruments - A System Approach. Jörg Müller Institut für Mikrosystemtechnik

Micro Analytical Instruments - A System Approach. Jörg Müller Institut für Mikrosystemtechnik Micro Analytical Instruments - A System Approach Jörg Müller Institut für Mikrosystemtechnik Technische h Universität i Hamburg-Harburg H b Outline Motivation Political Political Issues Design Principles

More information

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free Physical Properties Measurement System (PPMS): A Cryogen-free Physical Properties Measurement system that operates over a wider range of temperature and magnetic fields: fully automated/computer controlled

More information

Development of a Low Cost, Low Power, Miniature Sector Mass Spectrometer with IonCCD Detection

Development of a Low Cost, Low Power, Miniature Sector Mass Spectrometer with IonCCD Detection Leidos Proprietary Development of a Low Cost, Low Power, Miniature Sector Mass Spectrometer with IonCCD Detection Leidos; MIT MTL; Northeastern University; OI Analytical Development Team Noah Christian,

More information

Control and data acquisition system for SCR-1 Stellarator

Control and data acquisition system for SCR-1 Stellarator Control and data acquisition system for SCR-1 Stellarator J. Asenjo 1, V.I. Vargas 1 and J. Mora 1, 1 Instituto Tecnológico de Costa Rica, Cartago, 30101, Costa Rica May 8, 2017 Agenda SCR-1 Overview SCR-1

More information

PRISMAPRO. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit.

PRISMAPRO. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit. The latest generation of compact mass spectrometers. The combination of high sensi tivity, maximum

More information

Residual Gas Analyzers RGA100/200/ amu, 200 amu and 300 amu RGAs

Residual Gas Analyzers RGA100/200/ amu, 200 amu and 300 amu RGAs Residual Gas Analyzers RGA100/200/300 100 amu, 200 amu and 300 amu RGAs SRS Residual Gas Analyzers 100, 200 and 300 amu systems Better than 1 amu resolution 6 decades of dynamic range 5 10 14 Torr detection

More information

Miniaturized Ion and Neutral Mass Spectrometer for CubeSat Atmospheric Measurements

Miniaturized Ion and Neutral Mass Spectrometer for CubeSat Atmospheric Measurements Miniaturized Ion and Neutral Mass Spectrometer for CubeSat Atmospheric Measurements M. Rodriguez, N. Paschalidis, S. Jones, E. Sittler, D. Chornay, P. Uribe, NASA Goddard Space Flight Center T. Cameron,

More information

Density and temperature maxima at specific? and B

Density and temperature maxima at specific? and B Density and temperature maxima at specific? and B Matthew M. Balkey, Earl E. Scime, John L. Kline, Paul Keiter, and Robert Boivin 11/15/2007 1 Slide 1 Abstract We report measurements of electron density

More information

Residual Gas Analyzers

Residual Gas Analyzers Residual Gas Analyzers RGA100/200/300 100 amu, 200 amu and 300 amu systems SRS Residual Gas Analyzers 100, 200 and 300 amu systems Better than 1 amu resolution 6 decades of dynamic range 5 10 14 Torr detection

More information

A New Conjoined RF Ion Guide for Enhanced Ion Transmission

A New Conjoined RF Ion Guide for Enhanced Ion Transmission A New Conjoined RF Ion Guide for Enhanced Ion Transmission Kevin Giles and David Gordon Waters Corporation, Manchester, UK APPLICATION BENEFITS We describe a novel conjoined ion guide that operates at

More information

PRISMAPLUS. The precise solution for mass spectrometry. Modular design. Powerful software. Wide range of applications.

PRISMAPLUS. The precise solution for mass spectrometry. Modular design. Powerful software. Wide range of applications. PRISMAPLUS The precise solution for mass spectrometry. Modular design. Powerful software. Wide range of applications. PRISMAPLUS The precise solution for mass spectrometry. The combination of high sensi

More information

Miniaturized In-Situ Plasma Sensors Applications for NSF Small Satellite program. Dr. Geoff McHarg

Miniaturized In-Situ Plasma Sensors Applications for NSF Small Satellite program. Dr. Geoff McHarg Miniaturized In-Situ Plasma Sensors Applications for NSF Small Satellite program Dr. Geoff McHarg National Science Foundation Small Satellite Workshop- CEDAR June 2007 FalconSat-3 Physics on a small satellite

More information

MICROWAVE PLASMA CONTACTOR

MICROWAVE PLASMA CONTACTOR 369 IEPC-93-040 MICROWAVE PLASMA CONTACTOR Hitoshi Kuninaka* Institute of Space and Astronautical Science Yoshinodai, Sagamihara, Kanagawa, Japan Nobuo Hiroe**, Kazuto Kitaoka*, Yoshio Ishikawa + Nihon

More information

PrismaPlus. The New Mass Spectrometer with the Added Plus! Modular Design. Powerful Software. Wide Range of Applications.

PrismaPlus. The New Mass Spectrometer with the Added Plus! Modular Design. Powerful Software. Wide Range of Applications. PrismaPlus The New Mass Spectrometer with the Added Plus! Modular Design. Powerful Software. Wide Range of Applications. PrismaPlus The PrismaPlus innovation The optimum combination of high sensitivity,

More information

Construction Status of SuperKEKB Vacuum System

Construction Status of SuperKEKB Vacuum System Construction Status of SuperKEKB Vacuum System Mt. Tsukuba SuperKEKB ( 3000 m) Damping Ring Linac KEK Tsukuba site Fourth Workshop on the Operation of Large Vacuum systems (OLAV IV) April 2, 2014 Kyo Shibata

More information

Partial Replication of Storms/Scanlan Glow Discharge Radiation

Partial Replication of Storms/Scanlan Glow Discharge Radiation Partial Replication of Storms/Scanlan Glow Discharge Radiation Rick Cantwell and Matt McConnell Coolescence, LLC March 2008 Introduction The Storms/Scanlan paper 1 presented at the 8 th international workshop

More information

Collision cell: Fragmentation efficiency > 90 % Duty cycle: Variable between 1 and 50 % (user selectable trapping time/scan time ratio) Transmission:

Collision cell: Fragmentation efficiency > 90 % Duty cycle: Variable between 1 and 50 % (user selectable trapping time/scan time ratio) Transmission: Finnigan MAT 95 XP-API-GC-Trap tandem Mass spectrometer system Tandem Mass Spectrometer based on high resolution magnetic sector and Ion-Trap MS/MS system with API ( ESI, APCI ) and EI/CI ionization Mass

More information

Mass spectrometers have evolved into standard

Mass spectrometers have evolved into standard FOCUS: FIELD-PORTABLE AND MINIATURE MS Trade-offs in Miniature Quadrupole Designs S. Boumsellek and R. J. Ferran Ferran Scientific Inc., San Diego, California, USA Pressing needs for miniature mass spectrometers

More information

HIQUAD. New high-end mass spectrometer! Fast, flexible and easy to operate.

HIQUAD. New high-end mass spectrometer! Fast, flexible and easy to operate. New high-end mass spectrometer! Fast, flexible and easy to operate. New high-end mass spectrometer! Fast, flexible and easy to operate. A modular solution for mass spectrometry With the new HiQuad mass

More information

The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass

The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass Spectrometers. The Ionizer, Quadrupole Mass Filter, and Detector on a Mounting Flange are designed for inclusion in your experimental

More information

Improving Signal-to-Noise by Identifying Sources of Noise in Mass Spectrometer Systems

Improving Signal-to-Noise by Identifying Sources of Noise in Mass Spectrometer Systems GT-73A Improving Signal-to-Noise by Identifying Sources of Noise in Mass Spectrometer Systems Introduction: Kevin Kuchta Extrel CMS 575 Epsilon Drive, Pittsburgh, PA 538 (Poster presented at the 50th ASMS

More information

Neutral and Ion Measurements in the Ionosphere and Thermosphere: Neutral Wind, Ion-drift, Temperatures and Composition

Neutral and Ion Measurements in the Ionosphere and Thermosphere: Neutral Wind, Ion-drift, Temperatures and Composition DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Neutral and Ion Measurements in the Ionosphere and Thermosphere: Neutral Wind, Ion-drift, Temperatures and Composition

More information

Satellite Testing. Prepared by. A.Kaviyarasu Assistant Professor Department of Aerospace Engineering Madras Institute Of Technology Chromepet, Chennai

Satellite Testing. Prepared by. A.Kaviyarasu Assistant Professor Department of Aerospace Engineering Madras Institute Of Technology Chromepet, Chennai Satellite Testing Prepared by A.Kaviyarasu Assistant Professor Department of Aerospace Engineering Madras Institute Of Technology Chromepet, Chennai @copyright Solar Panel Deployment Test Spacecraft operating

More information

REVIEW OF HIGH POWER CW COUPLERS FOR SC CAVITIES. S. Belomestnykh

REVIEW OF HIGH POWER CW COUPLERS FOR SC CAVITIES. S. Belomestnykh REVIEW OF HIGH POWER CW COUPLERS FOR SC CAVITIES S. Belomestnykh HPC workshop JLAB, 30 October 2002 Introduction Many aspects of the high-power coupler design, fabrication, preparation, conditioning, integration

More information

Presentation SSC14-X-8

Presentation SSC14-X-8 Development Status and 1U CubeSat Application of Busek s.5n Green Monopropellant Thruster Presentation SSC14-X-8 Michael Tsay, Ph.D. Busek, Co. Inc. 11 Tech Cir, Natick, MA 176 August 2-7, 214 28 th Annual

More information

AccuTOF LC Training Course

AccuTOF LC Training Course 1 AccuTOF LC Training Course JEOL USA, Inc. 11 Dearborn Road Peabody, MA 01960 Area map Restaurants: Wendy s Bennigan s Bertucci s 2 AccuTOF LC Training Course Monday Basic principle and history of TOF

More information

ionospheric satellite cluster scientific premises and proposed configuration

ionospheric satellite cluster scientific premises and proposed configuration ionospheric satellite cluster scientific premises and proposed configuration O. Fedorov, Institute of Space Research, Kyiv, Ukraine V. Korepanov, Lviv Centre of Institute of Space Research, Lviv, Ukraine

More information

Development of Microwave Antenna for ECR Microwave Plasma Production

Development of Microwave Antenna for ECR Microwave Plasma Production THE HARRIS SCIENCE REVIEW OF DOSHISHA UNIVERSITY, VOL. 57, NO. 1 April 2016 Development of Microwave Antenna for ECR Microwave Plasma Production Camille Faith ROMERO* and Motoi WADA* (Received January

More information

Advantages of Multi-Turn-TOF Technology

Advantages of Multi-Turn-TOF Technology Advantages of Multi-Turn-TOF Technology Ordinary TOF vs. Multi-Turn TOF Ordinary TOF) TOF-MS is one of the most popular technologies for high resolution applications, particularly in ESI and MALDI instruments.

More information

Investigation of Various Microwave Electron Cyclotron Resonance Cathode Configurations

Investigation of Various Microwave Electron Cyclotron Resonance Cathode Configurations Investigation of Various Microwave Electron Cyclotron Resonance Cathode Configurations IEPC-2005-283 Presented at the 29 th International Electric Propulsion Conference, Princeton University, Hani Kamhawi

More information

High Power Couplers for TTF - FEL

High Power Couplers for TTF - FEL High Power Couplers for TTF - FEL 1. Requirements for High Power Couplers on superconducting Cavities 2. Characteristics of pulsed couplers 3. Standing wave pattern in the coaxial coupler line 4. Advantages

More information

Technical Readiness Level For Plasma Control

Technical Readiness Level For Plasma Control Technical Readiness Level For Plasma Control PERSISTENT SURVEILLANCE FOR PIPELINE PROTECTION AND THREAT INTERDICTION A.D. Turnbull, General Atomics ARIES Team Meeting University of Wisconsin, Madison,

More information

PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE

PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE K. Koppisetty ξ, H. Kirkici Auburn University, Auburn, Auburn, AL, USA D. L. Schweickart Air Force Research Laboratory, Wright

More information

CubeSat Propulsion using Electrospray Thrusters

CubeSat Propulsion using Electrospray Thrusters CubeSat Propulsion using Electrospray Thrusters Tom Roy, Nathaniel Demmons, Vlad Hruby, Nathan Rosenblad, Peter Rostler and Douglas Spence Busek Co., Natick, MA 01760 Paper SSC09-II-6 SmallSat Conference,

More information

Helicons - Our Last Year

Helicons - Our Last Year Helicons - Our Last Year Christian M. Franck and Thomas Klinger Max-Planck Institut für Plasmaphysik Teilinstitut Greifswald Euratom Association Outline Introduction The VINETA experiment Distinguishing

More information

Development of a High Temperature Venus Seismometer and Extreme Environment Testing Chamber

Development of a High Temperature Venus Seismometer and Extreme Environment Testing Chamber Development of a High Temperature Venus Seismometer and Extreme Environment Testing Chamber Gary W. Hunter, George E. Ponchak, Rodger W. Dyson, Glenn M. Beheim, Maximilian C. Scardelletti, and Roger D.

More information

Our Company. We are major supplier to:

Our Company. We are major supplier to: VACUUM METROLOGY Our Company Hositrad Holland and Hositrad Deutschland combine more than 50 years of experience in vacuum and cryogenic technology. Customers profit from a broad range of capabilities,

More information

Martian Outpost. Erik Seedhouse. The Challenges of Establishing a Human Settlement on Mars

Martian Outpost. Erik Seedhouse. The Challenges of Establishing a Human Settlement on Mars Erik Seedhouse Martian Outpost The Challenges of Establishing a Human Settlement on Mars o Published in association with / Springer praxis Publishing PRAXIS Contents Preface xiii Acknowledgments xv About

More information

Non-Destructive Ion Trap Mass Analysis at High Pressure. Supporting information

Non-Destructive Ion Trap Mass Analysis at High Pressure. Supporting information Non-Destructive Ion Trap Mass Analysis at High Pressure Supporting information Wei Xu 1, Jeffrey Maas 2, Frank Boudreau 3, William J. Chappell 2 and Zheng Ouyang 1,2,3* 1. Weldon School of Biomedical Engineering,

More information

Triplet polarimeter update

Triplet polarimeter update Triplet polarimeter update M. Dugger, February 2015 1 Plan Set up a polarimeter test bench in the Experimental Equipment Laboratory (EEL) Further test the silicon strip detector using fadc and sources

More information

NIST EUVL Metrology Programs

NIST EUVL Metrology Programs NIST EUVL Metrology Programs S.Grantham, C. Tarrio, R.E. Vest, Y. Barad, S. Kulin, K. Liu and T.B. Lucatorto National Institute of Standards and Technology (NIST) Gaithersburg, MD USA L. Klebanoff and

More information

An FT-ICR detection system for KATRIN

An FT-ICR detection system for KATRIN An FT-ICR detection system for KATRIN Marta Ubieto Díaz 1, Klaus Blaum 1, R. Burcu Cakirli 1, Michael Heck 1, Strahinja Lukić, Daniel Rodríguez 3, Lutz Schweikhard 4, Stefan Stahl 5 1 Max-Planck-Institut

More information

The SIRAD irradiation facility at the INFN - Legnaro National Laboratory

The SIRAD irradiation facility at the INFN - Legnaro National Laboratory The SIRAD irradiation facility at the INFN - Legnaro National Laboratory I. Introduction 2 The INFN - Legnaro National Laboratory (LNL) SIRAD beamline http://www.lnl.infn.it 3 What is SIRAD? SIRAD is the

More information

Physics Requirements for the CXI 0.1 micron Sample Chamber

Physics Requirements for the CXI 0.1 micron Sample Chamber PHYSICS REQUIREMENT DOCUMENT (PRD) Doc. No. SP-391-000-20 R1 LUSI SUB-SYSTEM Coherent X-Ray Imaging Physics Requirements for the Sébastien Boutet CXI Scientist, Author Signature Date Paul Montanez CXI

More information

Transpector 2. Gas Analysis System. NEW-GENERATION RGAs WITH SUPERIOR SENSITIVITY AND PERFORMANCE

Transpector 2. Gas Analysis System. NEW-GENERATION RGAs WITH SUPERIOR SENSITIVITY AND PERFORMANCE Transpector 2 Gas Analysis System NEW-GENERATION RGAs WITH SUPERIOR SENSITIVITY AND PERFORMANCE We ve made the best RGAs better. Inficon, the leaders in RGA technology, have upgraded the Transpector gas

More information

HYDROS Development of a CubeSat Water Electrolysis Propulsion System

HYDROS Development of a CubeSat Water Electrolysis Propulsion System HYDROS Development of a CubeSat Water Electrolysis Propulsion System Vince Ethier, Lenny Paritsky, Todd Moser, Jeffrey Slostad, Robert Hoyt Tethers Unlimited, Inc 11711 N. Creek Pkwy S., Suite D113, Bothell,

More information

Fast Rides. Uses of Fusion for Space Propulsion Systems

Fast Rides. Uses of Fusion for Space Propulsion Systems Fast Rides Uses of Fusion for Space Propulsion Systems Basic Idea of a Rocket F = m (d/dt) p Rocket equation: vf = u ln(mi/mf) (non-relativistic) So, higher exhaust velocity is better Vrms ~ 10^3 m/s (N2

More information

Laser-Produced Sn-plasma for Highvolume Manufacturing EUV Lithography

Laser-Produced Sn-plasma for Highvolume Manufacturing EUV Lithography Panel discussion Laser-Produced Sn-plasma for Highvolume Manufacturing EUV Lithography Akira Endo * Extreme Ultraviolet Lithography System Development Association Gigaphoton Inc * 2008 EUVL Workshop 11

More information

Multistage Transversal Modulation Ion Mobility Spectrometry: Reducing the Voltage Required for High Resolution IMS for pre-existing mass spectrometers

Multistage Transversal Modulation Ion Mobility Spectrometry: Reducing the Voltage Required for High Resolution IMS for pre-existing mass spectrometers Multistage Transversal Modulation Ion Mobility Spectrometry: Reducing the Voltage Required for High Resolution IMS for pre-existing mass spectrometers 1 Summary Introduction IMS-MS current technology.

More information

Low Temperature Plasma Technology Laboratory

Low Temperature Plasma Technology Laboratory Low Temperature Plasma Technology Laboratory Performance of a Permanent-Magnet Helicon Source at 7 and MHz Francis F. Chen LTP-7 July, Electrical Engineering Department Los Angeles, California 99-9 UNIVERSITY

More information

Aerosol Chemical Speciation Monitor ACSM

Aerosol Chemical Speciation Monitor ACSM ACSM Topics System Design -Lower cost Data acquisition thru Ethernet line and OPC, laptop Igor interface. Builds off of Squirrel tools Design Philosophy -fill the matrix -file formats -runtime view and

More information

The use of technical readiness levels in planning the fusion energy development

The use of technical readiness levels in planning the fusion energy development The use of technical readiness levels in planning the fusion energy development M. S. Tillack and the ARIES Team Presented by F. Najmabadi Japan/US Workshop on Power Plant Studies and Related Advanced

More information

Product Range Electronic Units

Product Range Electronic Units Pyramid Technical Consultants, Inc. 1050 Waltham Street Suite 200 Lexington, MA 02421 TEL: +1 781 402-1700 TEL (UK): +44 1273 492001 FAX: (781) 402-1750 EMAIL: SUPPORT@PTCUSA.COM Product Range Electronic

More information

The NASA and LVX System Partnership for Development of Light Communication Technologies

The NASA and LVX System Partnership for Development of Light Communication Technologies The NASA and LVX System Partnership for Development of Light Communication Technologies IEEE International Conference on Wireless for Space and Extreme Environments 2015 Jack Fox December 16, 2015 Topics

More information

Sub-mm Linear Ion Trap Mass Spectrometer Made Using Lithographically Patterned Ceramic Plates

Sub-mm Linear Ion Trap Mass Spectrometer Made Using Lithographically Patterned Ceramic Plates Sub-mm Linear Ion Trap Mass Spectrometer Made Using Lithographically Patterned Ceramic Plates Ailin Li Brigham Young University, Provo, UT Coauthors: Qinghao Wu, Yuan Tian, Derek Andrews, Aaron Hawkins,

More information

TOROIDAL ALFVÉN EIGENMODES

TOROIDAL ALFVÉN EIGENMODES TOROIDAL ALFVÉN EIGENMODES S.E. Sharapov Euratom/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxfordshire OX14 3DB, UK OUTLINE OF LECTURE 4 Toroidicity induced frequency gaps and Toroidal

More information

PHILTEC PHILTEC FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE SOLVE YOUR MEASUREMENT PROBLEMS FIBEROPTIC SENSORS

PHILTEC PHILTEC FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE SOLVE YOUR MEASUREMENT PROBLEMS FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE PHILTEC FIBEROPTIC SENSORS SOLVE YOUR MEASUREMENT PROBLEMS PHILTEC FIBEROPTIC SENSORS DISTANCE I DISPLACEMENT I VIBRATION PRODUCT GUIDE PHILTEC A P P L I C AT I O N S Aerospace

More information

EIE 528 Power System Operation & Control(2 Units)

EIE 528 Power System Operation & Control(2 Units) EIE 528 Power System Operation & Control(2 Units) Department of Electrical and Information Engineering Covenant University 1. EIE528 1.1. EIE 528 Power System Operation & Control(2 Units) Overview of power

More information

Ion Heating Arising from the Damping of Short Wavelength Fluctuations at the Edge of a Helicon Plasma Source

Ion Heating Arising from the Damping of Short Wavelength Fluctuations at the Edge of a Helicon Plasma Source Ion Heating Arising from the Damping of Short Wavelength Fluctuations at the Edge of a Helicon Plasma Source Division of Plasma Physics American Physical Society October 2012 Providence, RI Earl Scime,

More information

SPACE DEBRIS MENACE. GLYCAN SPACE XR- HELIOTORR Corp LLC Pasadena CA

SPACE DEBRIS MENACE. GLYCAN SPACE XR- HELIOTORR Corp LLC Pasadena CA WHITE PAGE Thanks to Title : SPACE DEBRIS MENACE GLYCAN SPACE XR- HELIOTORR Corp LLC Pasadena CA 201615810088 GLYCAN INDUSTRIES Corp LLC Pasadena CA AMERICAN INSTITUTE FOR QUANTUM SCIENCES AND PLASMA TECHNOLOGIES

More information

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

LC/MS/MS. Page Header. triple quadrupole mass spectrometer. LC/MS/MS VARIAN, INC. 320-MS Page Header triple quadrupole mass spectrometer www.varianinc.com VARIAN, INC. 320-MS Unsurpassed commitment to innovation Varian, Inc. is an innovator and leader in mass spectrometry

More information

Resonant Cavity Hollow Cathode Progress

Resonant Cavity Hollow Cathode Progress Resonant Cavity Hollow Cathode Progress IEPC-25-7 Presented at the 29 th International Electric Propulsion Conference, Princeton University, October 31 November 4, 25 Kevin D. Diamant The Aerospace Corporation,

More information

Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor

Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor Some Progress In The Development Of An Optical Readout System For The LISA Gravitational Reference Sensor Fausto ~cernese*', Rosario De ~ osa*~, Luciano Di Fiore*, Fabio ~arufi*', Adele La ~ana*' and Leopoldo

More information

Progress towards Actinic Patterned Mask Inspection. Oleg Khodykin

Progress towards Actinic Patterned Mask Inspection. Oleg Khodykin Progress towards Actinic Patterned Mask Inspection Oleg Khodykin Outline Status (technical) of EUV Actinic Reticle Inspection program Xe based LPP source as bright and reliable solution Requirements Choice

More information

Development of C-Mod FIR Polarimeter*

Development of C-Mod FIR Polarimeter* Development of C-Mod FIR Polarimeter* P.XU, J.H.IRBY, J.BOSCO, A.KANOJIA, R.LECCACORVI, E.MARMAR, P.MICHAEL, R.MURRAY, R.VIEIRA, S.WOLFE (MIT) D.L.BROWER, W.X.DING (UCLA) D.K.MANSFIELD (PPPL) *Supported

More information

ICP-MS. plasma 3. Multi-Collector ICP-MS.

ICP-MS. plasma 3. Multi-Collector ICP-MS. ICP-MS plasma 3 Multi-Collector ICP-MS www.nu-ins.com plasma 3 is a third generation Multi Collector ICP Mass Spectrometer (MC-ICP-MS), designed to provide the best possible precision and accuracy for

More information

Refer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both.

Refer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both. CERAVAC Transmitter CTR 100 N Short form manual 300544675_002_C0 Part numbers: 230 300V02 230 310V02 230 301V02 230 311V02 230 302V02 230 312V02 230 303V02 230 313V02 230 304V02 230 314V02 230 305V02 230

More information

SmartSenseCom Introduces Next Generation Seismic Sensor Systems

SmartSenseCom Introduces Next Generation Seismic Sensor Systems SmartSenseCom Introduces Next Generation Seismic Sensor Systems Summary: SmartSenseCom, Inc. (SSC) has introduced the next generation in seismic sensing technology. SSC s systems use a unique optical sensing

More information

Measuring the Ion Current to the Substrate During Deposition of Thin Films by Hollow Cathode Plasma Jet

Measuring the Ion Current to the Substrate During Deposition of Thin Films by Hollow Cathode Plasma Jet WDS'07 Proceedings of Contributed Papers, Part II, 212 217, 2007. ISBN 978-80-7378-024-1 MATFYZPRESS Measuring the Ion Current to the Substrate During Deposition of Thin Films by Hollow Cathode Plasma

More information

Features of Radio Frequency surface plasma sources with solenoidal magnetic field

Features of Radio Frequency surface plasma sources with solenoidal magnetic field Features of Radio Frequency surface plasma sources with solenoidal magnetic field V. Dudnikov 1,a), R.P. Johnson 1, B. Han 2, S. Murray 2, T. Pennisi 2, C. Piller 2, M. Santana 2, C. Stinson 2, M.Stockli

More information

XRF Instrumentation. Introduction to spectrometer

XRF Instrumentation. Introduction to spectrometer XRF Instrumentation Introduction to spectrometer AMPTEK, INC., Bedford, MA 01730 Ph: +1 781 275 2242 Fax: +1 781 275 3470 sales@amptek.com 1 Instrument Excitation source Sample X-ray tube or radioisotope

More information

Development of Under-Sodium Inspection Technique Using Ultrasonic Waveguide Sensor. FR13 4 ~ 7 Mar Paris, France

Development of Under-Sodium Inspection Technique Using Ultrasonic Waveguide Sensor. FR13 4 ~ 7 Mar Paris, France Development of Under-Sodium Inspection Technique Using Ultrasonic Waveguide Sensor FR13 4 ~ 7 Mar. 2013 Paris, France Young-Sang Joo, J.-H. Bae, C-G. Park and J.-B. Kim 1 Outline Under-Sodium Viewing (USV)

More information

RD51 ANNUAL REPORT WG1 - Technological Aspects and Development of New Detector Structures

RD51 ANNUAL REPORT WG1 - Technological Aspects and Development of New Detector Structures RD51 ANNUAL REPORT 2009 WG1 - Technological Aspects and Development of New Detector Structures Conveners: Serge Duarte Pinto (CERN), Paul Colas (CEA Saclay) Common projects Most activities in WG1 are meetings,

More information

TESLA RF POWER COUPLERS DEVELOPMENT AT DESY.

TESLA RF POWER COUPLERS DEVELOPMENT AT DESY. TESLA RF POWER COUPLERS DEVELOPMENT AT DESY. Dwersteg B., Kostin D., Lalayan M., Martens C., Möller W.-D., DESY, D-22603 Hamburg, Germany. Abstract Different RF power couplers for the TESLA Test Facility

More information

Advanced Tokamak Program and Lower Hybrid Experiment. Ron Parker MIT Plasma Science and Fusion Center

Advanced Tokamak Program and Lower Hybrid Experiment. Ron Parker MIT Plasma Science and Fusion Center Advanced Tokamak Program and Lower Hybrid Experiment Ron Parker MIT Plasma Science and Fusion Center Alcator C-Mod Program Advisory Meeting 23-24 February 2004 Main Goals of the Alcator C-Mod AT Program

More information

Characterization Of A Neutralizer-Free Gridded Ion Thruster

Characterization Of A Neutralizer-Free Gridded Ion Thruster Characterization Of A Neutralizer-Free Gridded Ion Thruster IEPC-2015-90256 /ISTS-2015-b-90256 Presented at Joint Conference of 30th International Symposium on Space Technology and Science 34th International

More information

The effect of phase difference between powered electrodes on RF plasmas

The effect of phase difference between powered electrodes on RF plasmas INSTITUTE OF PHYSICS PUBLISHING Plasma Sources Sci. Technol. 14 (2005) 407 411 PLASMA SOURCES SCIENCE AND TECHNOLOGY doi:10.1088/0963-0252/14/3/001 The effect of phase difference between powered electrodes

More information

Unpolarized Cluster, Jet and Pellet Targets

Unpolarized Cluster, Jet and Pellet Targets Unpolarized Cluster, Jet and Pellet Targets Intense Electron Beams Workshop Cornell University, June 17-19, 2015 Institut für Kernphysik Typical Requirements on Internal Targets Target material: H 2, D

More information

MICROWAVE HALL THRUSTER DEVELOPMENT

MICROWAVE HALL THRUSTER DEVELOPMENT MICROWAVE HALL THRUSTER DEVELOPMENT 1 Pedro MOLINA-MORALES, Hitoshi KUNINAKA, Kyoichiro TOKI Institute of Space and Astronautical Science (ISAS) 3-1-1 Yoshinodai, Sagamihara, Kanagawa, 229-851, Japan Yoshihiro

More information

Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS) Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS) Preamble An Inductively Coupled Plasma Mass Spectrometer (Quadrupole ICP-MS) is proposed to be procured

More information

Analysis of Potential for Venus-Bound Cubesat Scientific Investigations

Analysis of Potential for Venus-Bound Cubesat Scientific Investigations Analysis of Potential for Venus-Bound Cubesat Scientific Investigations Image Sources: Earth Science and Remote Sensing Unit, NASA Johnson Space Center; JAXA / ISAS / DARTS / Damia Bouic / Elsevier inc.

More information

ISUAL Test Plans and Procedures

ISUAL Test Plans and Procedures UCB Dwg. No: 8823-W7 Rev: A ISUAL Test Plans and Procedures Prepared by: H. Heetderks Approved by: S. Mende Revision History Rev Description By Date A Initial version containing summary material from dwg

More information

FAST KICKERS LNF-INFN

FAST KICKERS LNF-INFN ILC Damping Rings R&D Workshop - ILCDR06 September 26-28, 2006 at Cornell University FAST KICKERS R&D @ LNF-INFN Fabio Marcellini for the LNF fast kickers study group* * D. Alesini, F. Marcellini P. Raimondi,

More information

Beam Loss monitoring R&D. Arden Warner Fermilab MPS2014 Workshop March 5-6, 2014

Beam Loss monitoring R&D. Arden Warner Fermilab MPS2014 Workshop March 5-6, 2014 Beam Loss monitoring R&D Arden Warner Fermilab MPS2014 Workshop March 5-6, 2014 Outline PXIE Technical Concerns PXIE Study plans Preliminary scvd R&D Cold Ionization chambers 2 MPS2014; Arden Warner Loss

More information

The Perfect Solution for Mass Spectrometry. Modular Design. Powerful Software. Wide Range of Applications.

The Perfect Solution for Mass Spectrometry. Modular Design. Powerful Software. Wide Range of Applications. A P A S S I O N F O R P E R F E C T I O N PrismaPlus The Perfect Solution for Mass Spectrometry. Modular Design. Powerful Software. Wide Range of Applications. PrismaPlus The Perfect Solution for Mass

More information