FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

Size: px
Start display at page:

Download "FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard"

Transcription

1 FLAME RETARDANT INSTRUMENTATION CABLE Designation 150/250V TTY, FA-TTY, 150/250V TTYC, FA-TTYC, 150/250V TTYCY, FA-TTYCY 250V TTYC - Design guide : JIS C 3410(2010) - Flameretardant : IEC : IEC Category A (FA-s Only) - Cold bend/impact : CSA 22.2 No. 03 (-40 /-35 ) (Cold Type Only) - Max. rated conductor temperature : 70 TT - Stranded plain annealed copper wires as per JIS C 3410(2010) - PVC as per JIS C 3410(2010) - Two Insulated cores shall be twisted together to form a pair - Twisted pairs shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. Sheath Y - PVC as per JIS C3410(2010) Paint ProtectiveCovering C Y - Braid of galvanized steel wire(c). - Coverage density : Min. 90% - The white paint shall be painted uniformly on the steel wire braid - In case of PVC protective covering cable, paint isdispensable. - PVC as per JIS C3410(2010) - Protective covering color : Black - Any other color may be applicable when purchaser required. - Printed pair number and Alphabet letter on the white insulation - 1T, 1Q cable shall be identified by the black number on the white insulation 150/250V TTY, 150/250V TTYC, 150/250V TTYCY TTY TTYC TTYCY Strand Dia. TTY TTYC TTYCY mm 2 No./mm mm mm ±mm mm ±mm mm ±mm Ω/km MΩ - km kg/km kg/km kg/km 1P T Q P P P / P / P ,140 24P ,030 1,380 1,610 30P ,220 1,590 1,870 37P ,450 1,860 2,180 48P ,910 2,380 2,760

2 FLAME RETARDANT INSTRUMENTATION CABLE Designation 150/250V TTYSLA, FA-TTYSLA, 150/250V TTYCSLA, FA-TTYCSLA, 150/250V TTYCYSLA, FA-TTYCYSLA 150 / 250V TTYCYSLA - Design guide : JIS C 3410(2010) - Flameretardant : IEC : IEC Category A (FA-s Only) - Cold bend/impact : CSA 22.2 No. 03 (-40 /-35 ) (Cold Type Only) - Max. rated conductor temperature : 70 Commonshield 150/250V TTYSLA, 150/250V TTYCSLA, 150/250V TTYCYSLA Sheath Paint ProtectiveCovering TT SLA Y C Y - Stranded plain annealed copper wires as per JIS C 3410(2010) - PVC as per JIS C3410(2010) - Two Insulated cores shall be twisted together to form a pair - Twisted pairs shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. - Screened by AL/PS tape with tinned copper drain wire. - A suitable tape may be applied on the common shield - PVC as per JIS C3410(2010) - Braid of galvanized steel wire(c). - Coverage density : Min. 90% TTYSLA TTYCSLA TTYCYSLA Strand Dia. - The white paint shall be painted uniformly on the steel wire braid - In case of PVC protective covering cable, paint isdispensable. - PVC as per JIS C3410(2010) - Protective covering color : Black - Any other color may be applicable when purchaser required. - Printed pair number and Alphabet letter on the white insulation ex) 4P : (1A,1B), (2A, 2B), (3A, 3B), (4A, 4B) - 1T, 1Q cable shall be identified by the black number on the white insulation (Max.) (Min.) mm 2 No./mm mm mm ±mm mm ±mm mm ±mm Ω/km MΩ - km kg/km kg/km kg/km 1P T Q P P P / P / P ,160 24P ,190 1,400 1,630 30P ,280 1,610 1,890 37P ,520 1,880 2,200 48P ,990 2,410 2,790 TTYSLA TTYCSLA TTYCYSLA

3 FLAME RETARDANT INSTRUMENTATION CABLE 150 / 250V TTYC - SLA Designation 150/250V TTY-SLA, FA-TTY-SLA, 150/250V TTYC-SLA, FA-TTYC-SLA, 150/250V TTYCY-SLA, FA-TTYCY-SLA - Design guide : JIS C 3410(2010) - Flameretardant : IEC : IEC Category A (FA-s Only) - Cold bend/impact : CSA 22.2 No. 03 (-40 /-35 ) (Cold Type Only) - Max. rated conductor temperature : 70 TT - Stranded plain annealed copper wires as per JIS C 3410(2010) - PVC as per JIS C 3410(2010) - Two Insulated cores shall be twisted together to form a pair Individual shield 150/250V TTY-SLA,150/250V TTYC-SLA,150/250V TTYCY-SLA -SLA - Screened by AL/PS tape with tinned copper drain wire. - A suitable tape may be applied on the individual shield - Twisted pairs shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. Sheath Y -PVC as per JIS C 3410(2010) Paint ProtectiveCovering Note. Fire resistance type FR(A) & Cold type cable ( (C) ) can be supplied. C Y - Braid of galvanized steel wire(c). - Coverage density : Min. 90% TTY-SLA TTYC-SLA TTYCY-SLA Strand Dia. - The white paint shall be painted uniformly on the steel wire braid - In case of PVC protective covering cable, paint isdispensable. - PVC as per JIS C3410(2010) - Protective covering color : Black - Any other color may be applicable when purchaser required. - Printed pair number and Alphabet letter on the white insulation mm 2 No./mm mm mm ±mm mm ±mm mm ±mm Ω/km MΩ - km kg/km kg/km kg/km 4P P P P ,160 19P / ,030 1,320 1,540 24P ,370 1,710 2,020 30P ,600 1,970 2,300 37P ,900 2,300 2,670 48P ,500 2,960 3,440 TTY-SLA TTYC-SLA TTYCY-SLA

4 FLAME RETARDANT INSTRUMENTATION CABLE Designation 250V RCOP(OS) 250V RCOP (OS) - Design guide : IEC & IEC Flameretardant : IEC : IEC Category A (FA-s Only) - Cold bend/impact : CSA 22.2 No. 03 (-40 /-35 ) (Cold Type Only) - Max. rated conductor temperature : 90 - Stranded tinned annealed copper wires as per IEC 60228, Class 2 R - EPR as per IEC Two/Three Insulated cores shall be twisted together to form a pair/triad - Twisted pairs/triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used - Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Collectivescreen (OS) - AL/PS tape + Tinned copper drain wire (0.75mm 2 ) - A suitable tape may be applied on the collective screen Inner sheath C - SE1 as per IEC Outer sheath O P - Braid of plain annealed copper wires - Coverage density is minimum 90% - ST2 (PVC) as per IEC Outer sheath color : Grey (for Non-IS Type) or Blue (for IS Type) - Printed pair/triad number and Alphabet letter on the white insulation 2T : (1A, 1B, 1C), (2A, 2B, 2C)

5 (PAIR TYPE) 250VRCOP(OS) Strand Dia. Dia. Inner Sheath 1Q P P P P P P P 1.0 7/ , P 1.0 7/ , P ,040 16P ,160 19P ,300 20P ,350 24P ,590 30P ,000 37P ,310 *.1Quadcableshallbe twistedquad formation (TRIAD TYPE) 250VRCOP(OS) Strand Dia. Dia. Inner Sheath 2T T T T T T T ,130 12T 1.0 7/ ,050 1,280 14T ,410 16T ,590 19T ,810 20T ,980 24T ,280 30T ,730 37T ,260

6 FLAME RETARDANT INSTRUMENTATION CABLE Designation 250V RCOP(IS) 250V RCOP (IS) - Design guide : IEC & IEC Flameretardant : IEC : IEC Category A (FA-s Only) - Cold bend/impact : CSA 22.2 No. 03 (-40 /-35 ) (Cold Type Only) - Max. rated conductor temperature :90 - Stranded tinned annealed copper wires as per IEC 60228, Class 2 R - EPR as per IEC Individual screen (IS) - Two/Three Insulated cores shall be twisted together to form a pair/triad - AL/PS tape + Tinned copper drain wire (0.75mm 2 ) - A suitable tape may be applied on the individual screen - Twisted pairs/triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used - Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Inner sheath C - SE1 as per IEC Outer sheath O P - Braid of plain annealed copper wires - Coverage density is minimum 90% - ST2 (PVC) as per IEC Outer sheath color : Grey (for Non-IS Type) or Blue (for IS Type) - Printed pair/triad number and Alphabet letter on the white insulation 2T : (1A, 1B, 1C), (2A, 2B, 2C)

7 (PAIR TYPE) 250VRCOP(IS) Strand Dia. Dia. Inner Sheath 1P P P P P P P P / , P / ,050 1,100 14P ,220 16P ,370 19P ,510 20P ,590 24P ,980 30P ,350 37P ,750 (TRIAD TYPE) 250VRCOP(IS) Strand Dia. Dia. Inner Sheath 1T T T T T T T ,050 10T / ,050 1,270 12T / ,050 1,430 14T ,610 16T ,780 19T ,150 20T ,230 24T ,630 30T ,160 37T ,720

8 FIRE RESISANT INSTRUMENTATION CABLE Designation 250V FR-RCOP(OS) 250V FR RCOP (OS) - Design guide : IEC & IEC material : IEC , EPR - Sheathmaterial : IEC , SE1 & ST2 - Flameretardant : IEC & IEC Category A - Fire resistant : IEC & IEC or -2 (120minute) - Max. rated conductor temperature : 90 - Stranded tinned annealed copper wires as per IEC 60228, Class 2 - A suitable tape may be applied on the conductor Fire resistinglayer FR- - Mica/glass tape R - EPR as per IEC Two/Three Insulated cores shall be twisted together to form a pair/triad - Twisted pairs/triads shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. Collectivescreen (OS) - AL/PS tape + tinned copper drain wire - A suitable tape may be applied on the collective screen Inner sheath C - SE1 as per IEC O - Braid of plain annealed copper wires - A suitable separator tape(s) may be applied under/over the armour Outer sheath P - ST2 (PVC) as per IEC Printed pair/triad number and Alphabet letter on the white insulation 2T : (1A, 1B, 1C), (2A, 2B, 2C)

9 (PAIR TYPE) 250VFR-RCOP(OS) Dia. Strand Dia. Inner Sheath 1Q P P P P P P P / ,000 12P / ,120 14P ,210 16P ,370 19P ,510 20P ,590 24P ,960 30P ,350 37P ,730 *. 1 Quad cable shall be twisted quad formation (TRIAD TYPE) 250VFR-RCOP(OS) Strand Dia. Dia. Inner Sheath 2T T T T T T ,120 10T ,350 12T / ,520 14T ,770 16T ,960 19T ,250 20T ,330 24T ,700 30T ,250 37T ,830

10 FIRE RESISTANT INSTRUMENTATION CABLE Designation 250V FR-RCOP(IS) 250V FR RCOP (IS) - Design guide : IEC & IEC material : IEC , EPR - Sheathmaterial : IEC , SE1 & ST2 - Flameretardant : IEC & IEC Category A - Fire resistant : IEC & IEC or -2 (120minute) - Max. rated conductor temperature : 90 - Stranded tinned annealed copper wires as per IEC 60228, Class 2 - A suitable tape may be applied on the conductor Fire resistinglayer FR- - Mica/glass tape R - EPR as per IEC Two/Three Insulated cores shall be twisted together to form a pair/triad Collectivescreen (IS) - AL/PS tape + tinned copper drain wire - A suitable tape may be applied on the collective screen - Twisted pairs/triads shall be cabled. - Flame retardant & non-hygroscopic fillers may be used. - Suitable tape(s) may be applied on the cabled core. Inner sheath C - SE1 as per IEC O - Braid of plain annealed copper wires - A suitable separator tape(s) may be applied under/over the armour Outer sheath P - ST2 as per IEC Printed pair/triad number and Alphabet letter on the white insulation 2T : (1A, 1B, 1C), (2A, 2B, 2C)

11 (PAIR TYPE) 250VFR-RCOP(IS) Dia. Strand Dia. Inner Sheath 1P P P P P P P P / ,170 12P / ,290 14P ,460 16P ,640 19P ,880 20P ,970 24P ,370 30P ,800 37P ,230 (TRIAD TYPE) 250VFR-RCOP(IS) Dia. Strand Dia. Inner Sheath 1T T T T T ,030 7T ,090 8T ,220 10T / ,480 12T / ,770 14T ,950 16T ,170 19T ,510 20T ,620 24T ,050 30T ,690 37T ,360

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires

More information

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation

More information

SUPERIOR MARINE CABLE SOLUTIONS

SUPERIOR MARINE CABLE SOLUTIONS SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables

More information

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED ISSUE DATE: 04/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11 Plain Annealed Flexible Copper Conductors / PVC Insulated / Tinned

More information

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09) KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications

More information

Instrumentation Cables

Instrumentation Cables around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards

More information

Armoured Instrumentation Cables to BS6883

Armoured Instrumentation Cables to BS6883 Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring

More information

non-sheathed cables for fixed Wiring integrity is doing the right thing, even if nobody is Watching JiM stovall

non-sheathed cables for fixed Wiring integrity is doing the right thing, even if nobody is Watching JiM stovall non-sheathed cables for fixed Wiring integrity is doing the right thing, even if nobody is Watching JiM stovall 63 cables of our Manufacture NoN-SHeAtHeD CABLeS for fixed WiRiNG SINGLE-CORE NON-SHEATHED

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

NETWORK CONNECTIVITY SYSTEMS

NETWORK CONNECTIVITY SYSTEMS NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation

More information

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12-jack to RJ45-plug Ethernet connection line Cat.5, 4-pole, D-coded (IEC

More information

Tri-Rated Flexible PVC Equipment Wire

Tri-Rated Flexible PVC Equipment Wire Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier

More information

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable.   Features & Benefits Dual Wall 20ºC rated, Modified Polyester 99 wire has a dual wall construction of radiation crosslinked modified polyester. This combines excellent mechanical performance and chemical resistance with a

More information

UNIRAIL D RS485 and BUS cables

UNIRAIL D RS485 and BUS cables UNIRAIL D RS485 and BUS cables Type: 1x2x22 AWG/7 + 1x22 AWG/7 (1x2x0,35 + 1x0,35) Code: RW103A stranded tinned copper wire 22 AWG/7 (0,35 mm²) white blue POWER ELEMENTS: stranded bare copper wire 22 AWG/7

More information

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker

More information

MarineLine YOZp 0,6/1 kv

MarineLine YOZp 0,6/1 kv Properties Application: Light, armoured, reduced low voltage power cables for power and lighting applications in all ship areas. Characteristics: Class 2 s Light, reduced Halogen free and low smoke, flame

More information

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line

More information

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID ISSUE DATE: 05/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11:2011 Plain Annealed Flexible Copper Conductors / PVC Insulated / PVC Bedding / GSWB (Galvanised Steel Wire Braid) / PVC Sheathed.

More information

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

K20 & L120 LSZH Armoured F/FTP Cat6 Cables K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE

More information

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4 Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked

More information

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION

More information

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

WIRE & CABLE. 99 Wire Low fire hazard wire and cable Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard

More information

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology

More information

Technical Information PAS5308 Part 1 PAS5308 Cable Part 1 Color Code PAS5308 Cable Part 1 Ordering Code PA5308 Part 2 PAS5308 Cable Part 2 Color Code PAS5308 Cable Part 2 Ordering Code PAS 5308Part 2 49

More information

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CUSTOM DESIGN COAXIAL CABLES BY SICAB CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency

More information

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded

More information

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated

More information

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables NO: 452-1 Office

More information

Armoured Power and Control Cables to BS7917

Armoured Power and Control Cables to BS7917 1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications... Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control

More information

Technical Specification. for 1.1 KV Copper Control Cable

Technical Specification. for 1.1 KV Copper Control Cable WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,

More information

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

Armoured Power and Control Cables Fire Resistant

Armoured Power and Control Cables Fire Resistant Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity

More information

Armoured Power and Control Cables to BS6883

Armoured Power and Control Cables to BS6883 Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in

More information

SUBMERSIBLE PUMP CABLES

SUBMERSIBLE PUMP CABLES 12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum

More information

Control Cable. 1 Executive Standards. 3 Type and Designation. PVC insulated PVC sheathed control cable. PE insulated PE sheathed control cable

Control Cable. 1 Executive Standards. 3 Type and Designation. PVC insulated PVC sheathed control cable. PE insulated PE sheathed control cable Control Cable 1 Executive Standards GB9330-88 GB/T19666-005 It is manufactured according to GB9330-88 standards The low-smoking low-halogen low-smoking halogen-free flame-retardant cable, it complies with

More information

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Ship and Offhsore. Approved cables for ship- and offshoreindustry Ship and Offhsore Approved cables for ship- and offshoreindustry NEK Kabel AS - Norway. (NEK Sealine Marine products) tel. +47 67 91 21 80 - Firmapost@nek-kabel.no 1 OVER 100 YEARS OF EXPERIENCE 1913-2013

More information

Servo Cable Selection

Servo Cable Selection Servo Cables Servo Cable Selection Chainflex cable Jacket Shield Class Bending radius moving (factor x d) Temperature moving from/to F ( C) Oil-resistant V max. ft/s (m/s) unsupported V max. ft/s (m/s)

More information

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By : Power Cables Fire Resistant Cables Distributed By : WILSON CABLES PRIVATE LIMITED 142, Gul Circle, Jurong Industrial Estate, Singapore 629602 Tel : + 65 68617888 Fax : + 65 68617871 E-mail : exports@wilson-cables.com.sg

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like

More information

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813 with / without optical fibre elements 3.6/6 kv Contents: Letter code Construction details and voltage-classes Technical data 1 with / without optical fibre elements Letter code Flexible cables acc. to

More information

Cables for data transmission in industrial automation

Cables for data transmission in industrial automation Cables for data transmission in industrial automation The Quality Connection The LEONI Group Cable expertise for the most various industrial markets. LEONI is a leading supplier of cable systems and related

More information

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc. ()TSCGEWOEU TEAX TTS-LWL 3,6/6 kv: Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high mechanical

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded

More information

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires

More information

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications. Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001 Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001-10 Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated

More information

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables 5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables Applications Three copper conductors cable, each with a semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE

More information

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4 Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T

More information

High Temperature Flexible Control Cable OLFLEX

High Temperature Flexible Control Cable OLFLEX High Temperature Flexible Control Cable 6 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-60-Main Office: (60) 88-900-Outside Local Area: (800) 8-900-www.stevenengineering.com

More information

FieldLink MC at 20 x outer diameter Torsion

FieldLink MC at 20 x outer diameter Torsion Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation

More information

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary TRAY-RATED CABLE Quick Select Chart 48 TC 600/TC 600 S 50 Flexible Tray Cable with TC-ER for Easier Installations; Unshielded & Shielded TRAY II/TRAY II CY 52 Extremely Oil-Resistant & Flexible Tray Cable

More information

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction: Addison www.addison-tech.com www.addison-cables.com Profibus SK Indoor + Outdoor Application: The application of these Profibus SK cables are in the cell and field area, just as for conventional types.

More information

P Low Voltage Catalogue Cables Australia Powering your Project

P Low Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 Low Voltage Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated distributor of high

More information

MULTIMEDIA CABLE H6091ZHB

MULTIMEDIA CABLE H6091ZHB CAVEL News MULTIMEDIA CABLE H6091ZHB MULTIMEDIA CABLE H6091ZHB Multimedia is a must in the modern way of life. Growing communication needs in any environment whether at home or the office the connection

More information

T E C H N I C A L D A T A for

T E C H N I C A L D A T A for Page 2 of 33 T E C H N I C A L D A T A for Electrical, Instrumentation and Communication Offshore LIST OF CONTENT: RFXU 0,6/1KV, BLACK SHEATH, UNARMOURED...4 CONSTRUCTION...4 RANGE AND DIMENSIONS RFXU

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2 Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded

More information

Product information. Marine, Oil & Gas.

Product information. Marine, Oil & Gas. Product information Marine, Oil & Gas www.drakamog.com DRAKA Product information MOG 2010 Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTENATIONAL STANDAD IEC 60092-376 Second edition 2003-05 Electrical installations in ships Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) Installations électriques à bord

More information

Instrumentation Cable PLTC/ITC and TC Types

Instrumentation Cable PLTC/ITC and TC Types Instrumentation Cable PLTC/ITC and TC Types The Quality Connection 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for

More information

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation

More information

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

11-SDMS-03 REV. 02 SPECIFICATIONS FOR 11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice

More information

Microwave Coax Cable

Microwave Coax Cable Cable LINCOS microwave coaxial cable basic construction is shown below : Ø 1. Inner Conductor : Solid or Strand Sliver Plated Copper Ø 2. Insulation : Wrapped Low Density PTFE Ø 3. Outer Conductor : Sliver

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive

More information

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum. FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared

More information

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum

More information

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships Tray Cable Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for over 35 years, Texcan

More information

SAC-5P- 1,5-PUR/M12FS SH

SAC-5P- 1,5-PUR/M12FS SH Extract from the online catalog SAC-5P- 1,5-PUR/M12FS SH Order No.: 1682935 Sensor/Actuator cable, 5-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Free conductor end M12, on Socket, straight

More information

The Quality Connection. ICON Product Guide

The Quality Connection. ICON Product Guide The Quality Connection ICON Product Guide 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for special applications Instrumentation-

More information

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables Cables for Data Transmission in Industrial Automation Fieldbus Cables Copper Cables Fibre Optic Cables 2 KERPEN GmbH & Co. KG 2005 2.2006 Printing errors excepted. Subject to alteration. Contents Seite

More information

EXCELLENT ELECTRICAL PERFORMANCES

EXCELLENT ELECTRICAL PERFORMANCES 50OHMS CORRUGATED COPPER TUBE COAXIAL CABLE PRODUCT INTRODUCTION 2 Hansen's manufacturing of wide-scope 50ohms corrugated copper coaxial Cable is the fruitful result of the engineers' diligent research

More information

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT TPE-INSULATED CABLES Products TPE - Cables TPE-INSULATED CABLES 105 C O N T E N T S C O N T E N T S Page TPE single cores according to DIN 72551, type A 107 TPE single cores according to DIN 72551, type

More information

ABOUT US ABOUT US 1 CRANE CABLES

ABOUT US ABOUT US 1 CRANE CABLES ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its

More information

Selection table for flat & ribbon cables

Selection table for flat & ribbon cables Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON

More information

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485 Content Page Certificates 3 Industrial Cables Production 4-5 Industrial Cables of PJSC «Odeskabel» 6 КИФ-В for RS485 (CAN) КИФ-В 1х2х0,6; КИФ-В 1,5х2х0,6; КИФ-В 2х2х0,6; КИФ-В 3х,2х0,6; КИФ-В 4х2х0,6 8

More information

DNVGL-CP-0400 Edition December 2015

DNVGL-CP-0400 Edition December 2015 CLASS PROGRAMME Type approval DNVGL-CP-0400 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Welding Cables Rubber Insulated

Welding Cables Rubber Insulated Welding Cables Rubber Insulated C 0 V Application Primary use is for the secondary (high current) connection to automatic or hand-held metal arc welding electrodes. May also be used for non-welding applications

More information

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION SOLUTIONS COAXIAL CABLES BUILDING MANAGEMENT SYSTEMS BROADCASTING & STUDIO Prysmian Group Linking

More information

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction: Caledonian www.caledonian-cables.co.uk www.caledonian-cables.net Profibus L2 Indoor Application: This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the

More information

WIRE&CABLE FILS&CÂBLES S I N C E

WIRE&CABLE FILS&CÂBLES S I N C E WIRE&CABLE FILS&CÂBLES 50 CELEBRATING 50+ YEARS S I N C E 1 9 6 0 Dear Friend: Thank you for choosing Provo Ltd. As the leader in providing Canadian industry, coast-to-coast with a full line of electronic

More information

List Price w.e.f. 02nd January, 2018

List Price w.e.f. 02nd January, 2018 w.e.f. 02nd January, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic

More information

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD(RTS)

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 24 AWG stranded (7x32) TC conductor, Datalene insulation, pairs individually shielded with bonded Beldfoil with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil

More information

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and

More information

FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS

FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS HIGH SPEED DS-3 & DS-4 CABLES Belden Your Widest Selection for Meeting DS-3 and DS-4 Network Requirements BELDEN, THE CABLE TECHNOLOGY LEADER IN HIGH-SPEED

More information

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD

More information

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable 05 63 Technical information 64 Primary Wire 66 Brake Cable & Portable Extension Cable 67 SXL & Bonded Wire WIRE & CABLE FILS ET CÂBLES 68 Trailer Cable 70 Battery Cable 71 Welding Cable 72 Booster Cable

More information

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no) GameChanger Cable Unshielded Twisted Pair Riser Rated - CMR 258310333 46224PRYWB (legacy part no) 1.0 Scope 1.1 This cable consists of 4 pair solid bare copper; color-coded high density polyethylene (HDPE)

More information

Power-limited Circuit Cable. Features & Applications: Specification. Power-limited Circuit Cable

Power-limited Circuit Cable. Features & Applications: Specification. Power-limited Circuit Cable Power-limited Circuit Cable Power-limited Circuit Cable (UL) E489959-N CLXX XX AWG XX C CLXX: UL13 Cable Type Plenum Rated: (2P), (3P) Riser Rated: (2R), (3R) General Rated: (2), (3) Residential Rated:

More information