Instrumentation Cables

Size: px
Start display at page:

Download "Instrumentation Cables"

Transcription

1 around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES

2 Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards 300V Applications and Description 300V 5 C PVC Insulated, Unshielded Pairs ITC/PLTC 300V 5 C PVC Insulated, Unshielded Triads ITC/PLTC 300V 5 C PVC Insulated, Unshielded Pairs with Overall Shield ITC/PLTC 300V 5 C PVC Insulated, Unshielded Triads with Overall Shield ITC/PLTC 300V 5 C PVC Insulated, Individual Pairs with Overall Shield ITC/PLTC 300V 5 C PVC Insulated, Individual Triads with Overall Shield ITC/PLTC 00V Applications and Description 00V PVC/Nylon/PVC Overall Shielded Pairs/Triads TC-ER Rated 00V PVC/Nylon/PVC Individual and Overall Shielded Pairs TC-ER Rated Notice

3 Introduction M CABLE CO. INC. Founded in 993, M CABLE is a high-technology cable manufacturer specializing in all types of Low Voltage cables. The company is headquartered in Istanbul, Turkey and operates in a ft area. Our Sales office and a warehouse in Moscow/Russia has succesfully been active since year 005. M CABLE has been a reliable manufacturer and supplier to the sectors such as; Construction (High rise, intelligent&semi intelligent buildings, hospitals, universities, residence projects, etc.), Oil & Gas, Petrochemical, Power Plant Projects, Automation, Fire & Security, Satellite, Broadcasting, Audio-Video We export to more than countries worldwide (Mostly to Europe, MEA Countries, CIS Countries and South East Asia).

4 Instrumentation Cables M CABLE manufactures instrumentation cable mostly for refineries and petrochemical plants. Our Engineering and Designing team have knowledge of supporting cable needs for large projects in USA, Europe, Middle East, South East Asia, South America and Far East. TRAY CABLES Tray cable, made for Control and Signaling Systems (*NEC Article 33) are used in petrochemical refineries, industrial control systems, intercom systems, traffic controls relay, power extensions. The cable is recognized for use in Class and, Division, hazardous locations and for installation in trays, wire ways, troughs, ducts, conduit and channels. ITC/PLTC CABLES ITC/PLTC Cables have a wide range of application in process control and data processes, in analogue and digital signal transmission and power limited circuits. Factories, burglar alarms, business machines, refineries, petrochemical plants, intercom systems, industrial control systems, power plants, natural gas filling plants and etc. make up the general areas that these cables are used. 3

5 Specialty Cables We are also capable of designing and manufacturing tailor made cables customized according to your specific needs and as per your requirements of application. Many types of cables are available at your request.

6 Instrumentation Cables 300V & 00V INSTRUMENTATION CABLE TYPES

7 300V Instrumentation Cables M CABLE UL 300V Instrumentation Cable Meets All Applicable Specifications UL 3 UL UL 5 NEC Type PLTC per Article 75 NEC Type ITC per Article 77 For International Projects, the quality certificates we have & the standards we follow; Certificates LPCB VDE RINA Standards IEC BS EN GOST TSE

8 300V Instrumentation Cables 300V, PVC Insulated, 5 C Type PLTC UL 3 NEC ART 75 Type ITC UL NEC ART 77 Applications Soft annealed bare or tinned copper conductors and PVC flame retardant insulations and jackets are the standard for 300V instrumentation installation. Constructions with PVC/PVC that have three or more conductors and 0 AWG or larger conductors may also be used for direct burial installations. Construction Conductor Bare, Tin-Coated, annealed copper, in solid, 7-strand, or 9-strand configurations from 0 AWG to AWG. Insulation Polyvinyl chloride in accordance with UL 3 and UL, flame retardant, 5 C temperature rating. Insulation Shield (on shielded pair/triad constructions) M Cable provides many options for shielding to prevent EMI (electro-magnetic interference) within the twisted pairs, triads and for the overall cable using Overall Foil Shield, Aluminum/Polyester Foil and Aliminum Foil. Jacket UL listed sunlight and moisture resistant, black, flame retardant polyvinyl chloride material. Features UL approved Type PLTC and ITC, 300V UL approved insulated conductors Cables pass UL 5 and IEEE 33 vertical fire tests at 70,000 BTU/hr Temperature rating 5 C Sunlight and moisture resistant jacket UL 3 and The overall jackets of these cables are a gas/vapour tight continuous sheath in Class and Class 3 Circuits, as defined in NEC ART 75 for Type PLTC cables. 7

9 300V Instrumentation Cables 300V 5 C PVC Insulated Unshielded Pairs ITC/PLTC Construction Conductor Plain annealed copper wires (7-stranded) size AWG, AWG, AWG, AWG 0 (ASTM B-3, Class B stranding per ASTM B-) Insulation Heat resistant PVC (UL 5 class 5 C, EN 33-3 TI3) Core Colors Black, white, continuously numbered on white core (,,3) for multielement Separator Polyester tape (at least layer) Sheath Heat resistant and sunlight resistant PVC (UL 5 class 5 C) colour Black, Blue [other colors upon request] Reference Standard UL 3 - UL Technical and Electrical Properties (0 C) Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft) Insulation Thickness (mils) Insulation Resistance (MΩxkft) Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests Oil Resistance 300 V Core-Core V Core-Screen V AWG AWG AWG AWG 0.7 Ω/kft.3 Ω/kft).95 Ω/kft.9 Ω/kft at 5. C fixed -0 C...+5 C during installation -5 C...+ C 7.5 x Cable diameter Min. 7% UL 5 (vertical tray), UL 3 (VW-), IEC/EN 033-, IEC (CAT-A), (BS 0 part &3), EN -- ASTM No oil 70 C (ICEA S-73-53)

10 V Instrumentation Cables */7 */7 */7 *0/7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Pair Number Copper Weight Cable Weight (±0.0) (±0.05)

11 300V Instrumentation Cables 300V 5 C PVC Insulated Unshielded Triads ITC/PLTC Construction Conductor Plain annealed copper wires (7-stranded) size AWG, AWG, AWG, AWG 0 (ASTM B-3, Class B stranding per ASTM B-) Insulation Heat resistant PVC (UL 5 class 5 C, EN 33-3 TI3) Core Colors Black, white, red continuously numbered on white core (,,3) for multielement Separator Polyester tape (at least layer) Sheath Heat resistant and sunlight resistant PVC (UL 5 class 5 C), colour Black, Blue [other colors upon request] Reference Standard UL 3 - UL Technical and Electrical Properties (0 C) Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft) Insulation Thickness (mils) Insulation Resistance (MΩxkft) Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests Oil Resistance Sunlight Resistance 300V Core-Core V Core-Screen V AWG AWG AWG AWG 0.7 Ω/kft.3 Ω/kft.95 Ω/kft.9 Ω/kft at 5. C fixed -0 C...+5 C during installation -5 C...+ C 7.5 x Cable diameter Min. 7% UL 5 (vertical tray), UL 3 (VW-), IEC/EN 033-, IEC (CAT-A), (BS 0 part &3), EN -- ASTM No oil 70 C (ICEA S-73-53) UL 5 section 00

12 300V Instrumentation Cables */7 */7 */7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Triad Number Copper Weight Cable Weight (±0.0) (±0.05)

13 300V Instrumentation Cables *0/7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Triad Number Copper Weight Cable Weight (±0.0) (±0.05)

14 300V Instrumentation Cables 300V 5 C PVC Insulated, Unshielded Pairs with Overall Shield ITC/PLTC Construction Conductor Plain annealed copper wires (7-stranded) size AWG, AWG, AWG, AWG 0 (ASTM B-3, Class B stranding per ASTM B-) Insulation Heat resistant PVC (UL 5 class 5 C, EN 33-3 TI3) Core Colors Black, white, continuously numbered on white core (,,3) for multielement Separator Polyester tape (at least layer) Overall shield Plastic coated aluminum tape in contact with tinned copper drain wire. Communication Wire Stranded plain annealed copper wire, size AWG, PVC insulated colored orange Sheath Heat resistant and sunlight resistant PVC (UL 5 class 5 C), colour Black, Blue [other colors upon request] Reference Standard UL 3 - UL Technical and Electrical Properties (0 C) Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft) L/R ratio (max.μh/ω) Insulation Thickness (mils) Insulation Resistance (MΩxkft) Capacitance (00 Hz) pf/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests Oil Resistance 300V Core-Core V Core-Screen V AWG AWG AWG AWG 0.7 Ω/kft.3 Ω/kft.95 Ω/kft.9 Ω/kft at 5. C 5. fixed -0 C...+5 C during installation -5 C...+ C 7.5 x Cable diameter Min. 7% UL 5 (vertical tray), UL 3 ( VW-), IEC/EN 033-, IEC (CAT-A), (BS0 part &3), EN -- ASTM No oil 70 C (ICEA S-73-53) 3

15 300V Instrumentation Cables */7 */7 */7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Pair Number Copper Weight Cable Weight (±0.0) (±0.05)

16 V Instrumentation Cables *0/7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Pair Number Copper Weight Cable Weight (±0.0) (±0.05)

17 300V Instrumentation Cables 300V 5 C PVC Insulated, Unshielded Triads with Overall Shield ITC/PLTC Construction Conductor Plain annealed copper wires (7-stranded) size AWG, AWG, AWG, AWG 0 (ASTM B-3, Class B stranding per ASTM B-) Insulation Heat resistant PVC (UL 5 class 5 C, EN 33-3 TI3) Core Colors Black, white, red continuously numbered on white core (,,3) for multielement Separator Polyester tape (at least layer) Overall Shield Plastic coated aluminum tape in contact with tinned copper drain wire Communication Wire Stranded plain annealed copper wire, size AWG, PVC insulated colored orange Sheath Heat resistant and sunlight resistant PVC (UL 5 class 5 C), colour Black, Blue [other colors upon request] Reference Standard UL 3 - UL Technical and Electrical Properties (0 C) Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft) L/R ratio (max.μh/ω) Insulation Thickness (mils) Insulation Resistance (MΩxkft) Capacitance (00 Hz) pf/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests Oil Resistance Sunlight Resistance 300V Core-Core V Core-Screen V AWG AWG AWG AWG 0.7 Ω/kft.3 Ω/kft.95 Ω/kft.9 Ω/kft at 5. C 5. fixed -0 C...+5 C during installation -5 C...+ C 7.5 x Cable diameter Min. 7% UL 5 (vertical tray), UL 3 (VW-), IEC/EN 033-, IEC (CAT-A), (BS 0 part &3), EN -- ASTM No oil 70 C (ICEA S-73-53) UL 5 section 00

18 V Instrumentation Cables */7 */7 */7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Triad Number Copper Weight Cable Weight (±0.0) (±0.05)

19 300V Instrumentation Cables *0/7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Triad Number Copper Weight Cable Weight (±0.0) (±0.05)

20 300V Instrumentation Cables 300V 5 C PVC Insulated, Individual Pairs with Overall Shield ITC/PLTC Technical and Electrical Properties (0 C) Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft) L/R ratio (max.μh/ω) Insulation Thickness (mils) Insulation Resistance (MΩxkft) Capacitance (00 Hz) pf/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests Oil Resistance Construction Conductor Plain annealed copper wires (7-stranded) size AWG, AWG, AWG, AWG 0 (ASTM B-3, Class B stranding per ASTM B-) Insulation Heat resistant PVC (UL 5 class 5 C, EN 33-3 TI3) Core Colors Black, white, continuously numbered on white core (,,3) for multielement Individual Shield Plastic coated aluminum tape in contact with tinned copper drain wire. Separator Polyester tape (at least layer) Overall shield Plastic coated aluminum tape in contact with tinned copper drain wire. Communication Wire Stranded plain annealed copper wire, size AWG, PVC insulated colored orange Sheath Heat resistant and sunlight resistant PVC (UL 5 class 5 C), colour Black, Blue [other colors upon request] Reference Standard UL 3 - UL 300V Core-Core V Core-Screen V AWG AWG AWG AWG 0.7 Ω/kft.3 Ω/kft.95 Ω/kft.9 Ω/kft at 5. C 5. fixed -0 C...+5 C during installation -5 C...+ C 7.5 x Cable diameter Min. 7% UL 5 (vertical tray), UL 3 (VW-), IEC/EN 033-, IEC (CAT-A), (BS 0 part &3), EN -- ASTM No oil 70 C (ICEA S-73-53) 9

21 V Instrumentation Cables */7 */7 */ Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Pair Number Copper Weight Cable Weight (±0.0) (±0.05) 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,0 0,00 0,00 0,00 0,00 0,090 0,0 0,0 0,00 0,00 0,00 0,00 0,090 0,0 0,0 0,0 0,00 0,00 0,00,7,5,5,03,03,9,7,7,5,5,5,03,9,7,7,7,5,5,03 0,59 5 0,7 0,99,0,99,90,3,9 0, 3 5 0,0 0, 0,99,0,0,59 0,03 0, 0,553 0,7 0,7 0, 0,935,03, ,, 9,3 5,,0 30, 3,7 3,3 9,3,3 3,0,,0 5,,5 9,9 0,,,,0,,, 3,7, 35,

22 300V Instrumentation Cables *0/7 0 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Pair Number Copper Weight Cable Weight (±0.0) (±0.05) 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,00 0,0 0,0 0,00 0,00 0,00,0,7,7,5,5,5 95 0, 0,0 0, 0,7 0,935,0, ,3,0, 5, 5,, 3,7,0 9,

23 300V Instrumentation Cables 300V 5 C PVC Insulated, Individual Triads with Overall Shield ITC/PLTC Technical and Electrical Properties (0 C) Operating Voltage Test Voltage Conductor Cross Section Conductor Resistance (Ω/kft) L/R ratio (max.μh/ω) Insulation Thickness (mils) Insulation Resistance (MΩxkft) Capacitance (00 Hz) pf/ft Temperature Range Min. Bending Radius (fixed) Oxygen Index Flame Tests Oil Resistance Sunlight Resistance Construction Conductor Plain annealed copper wires (7-stranded) size AWG, AWG, AWG, AWG 0 (ASTM B-3, Class B stranding per ASTM B-) Insulation Heat resistant PVC (UL 5 class 5 C, EN 33-3 TI3 ) Core Colors Black, white, red continuously numbered on white core (,,3) for multielement Individual Shield Plastic coated aluminum tape in contact with tinned copper drain wire. Separator Polyester tape (at least layer) Overall Shield Plastic coated aluminum tape in contact with tinned copper drain wire. Communication Wire Stranded plain annealed copper wire, size AWG, PVC insulated colored orange Sheath Heat resistant and sunlight resistant PVC (UL 5 class 5 C) colour Black, Blue [other colors upon request] Reference Standard UL 3 - UL 300V Core-Core V Core-Screen V AWG AWG AWG AWG 0.7 Ω/kft.3 Ω/kft.95 Ω/kft.9 Ω/kft at 5. C 5. fixed -0 C...+5 C during installation -5 C...+ C 7.5 x Cable diameter Min. 7% UL 5 (vertical tray), UL 3 (VW-), IEC/EN 033-, IEC (CAT-A), (BS 0 part &3), EN -- ASTM No oil 70 C (ICEA S-73-53) UL 5 section 00

24 V Instrumentation Cables */7 */7 */7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Triad Number Copper Weight Cable Weight (±0.0) (±0.05) 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,0 0,00 0,00 0,00 0,00 0,090 0,0 0,0 0,00 0,00 0,00 0,00 0,090 0,0 0,0 0,0 0,00 0,00 0,00 0,00,7,5,5,03,03,9,7,7,5,5,5,03,9,7,7,7,5,5,5,03 0,5 0,9 0,0 0,97,097,3,,353,59, 0,9 0,57 0,70 0,793 0,99 0,95,05,3,35,79 0,9 0,0 0,70 0,797 0,0 0,93,, , 7,7,3,5 7,, 3,0 3,3 55,0,5,5 7,9 0,,,,7, 33, 5,,,9 5, 7, 0, 0,,9 9, 39,

25 300V Instrumentation Cables *0/7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Triad Number Copper Weight Cable Weight (±0.0) (±0.05) 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,0 0,00 0,0 0,0 0,0 0,00 0,00 0,00 0,00,0,7,7,7,5,5,5,5 5 0,9 0,59 0,3 0,757,03 0,95, ,0,9,9,, 7,3 9,,3, 3,

26 Instrumentation Cables

27 Instrumentation Cables

28 00V Instrumentation Cables 00V, PVC/Nylon Insulated, 90 C Type TC UL 77 NEC ART 33 Applications The 00V Instrumentation Cables are listed as Type TC per UL 77. Suitable for installations as described in NEC ART 33. Construction Conductor Bare, annealed copper conforming to ASTM B-3 and Class B stranded in accordance to ASTM B-. Insulation PVC/Nylon Type Flame retardant, 90 C temperature rating. Insulation Shield (Shielded pair/triad constructions) Aluminum foil/polyester shield helically wrapped to provide 0 % coverage with a tinned copper drain wire that is two gauge sizes smaller than the circuit conductors Jacket UL listed sunlight and moisture resistant, sequentially length marked, black, flame retardant polyvinyl chloride material. A Nylon ripcord can be included for ease of jacket removal. Features UL approved Type TC, 00V UL approved insulated conductors UL 5 and IEEE 33 vertical fire tests at 70,000 BTU/hr Temperature rating 90 C dry Sunlight and moisture resistant jacket For use within Class Division and Class Division Hazardous Locations and Intrinsically Safe applications as permitted by NEC ART 39,,, and 5. Cables are rated for Direct Burial applications For use in cable trays, raceways, conduit or for aerial applications where installed with a messenger Cables may be used In Class Circuits, as defined in NEC Section 33. and ART 75 for Type TC cables The Nylon jacket provides excellent oil and gasoline protection. Specifications UL 77 Rated 90 C / 00V UL requirements for Type TC Designated Type TC per NEC ART

29 00V Instrumentation Cables 00V PVC/Nylon/PVC Overall Shielded Pairs/Triads TC-ER Rated Construction Conductor Plain annealed stranded copper wires (ASTM B3, Class B stranding per ASTM B- IEC/EN, HD 33, BS 30, VDE 095) Insulation Heat resistant PVC (UL 5 class 90 C, EN 33-3 TI3) with clear Polyamide (Nylon) Separator Polyester tape (at least layer) Drain Wire Solid tinned copper wire AWG 7x Inc. AWG 7x0.0 Inc. Shield AL-PES foil, Aluminum contact with stranded tinned copper drain wire Sheath Heat resistant and sunlight resistant PVC (UL 5 class 90 C) Reference Standard UL 77 Technical and Electrical Properties (0 C) Max. Operating Voltage Conductor Resistance (Ω/kft) Insulation Thickness (mils) Min. Bending Radius (fixed) Temperature Rate Oxygen Index Flame Tests Oil Resistance 00V AWG.3 (.3 Ω/kft) AWG.7 (.95 Ω/kft) AWG 9 mils PVC + 0. mm Nylon AWG 5.3 mils PVC +.73 mils Nylon 7.5 x Cable Diameter Dry 90 C Min. 7% UL 5 (vertical tray), UL 3 (VW-), IEC/EN 033-, IEC (CAT-A), (BS 0 part &3), EN -- ASTM No oil 70 C (ICEA S-73-53)

30 9 00V Instrumentation Cables TRI TRI */7 */ Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Pair Number Copper Weight Cable Weight (±0.0) (±0.05)

31 00V Instrumentation Cables 00V PVC/Nylon/PVC Individual and Overall Shielded Pairs TC-ER Rated Technical and Electrical Properties (0 C) Max. Operating Voltage Conductor Resistance (Ω/kft) Insulation Thickness (mils) Min. Bending Radius (fixed) Temperature Rate Oxygen Index Flame Tests Oil Resistance Construction Conductor Plain annealed stranded copper wires (ASTM B3, Class B stranding per ASTM B- IEC/EN, HD 33, BS 30, VDE 095) Insulation Heat resistant PVC (UL 5 class 90 C, EN 33-3 TI3) with clear Polyamide (Nylon) Individual Separator Polyester tape Individual Drain Wire Solid tinned copper wire AWG 7x Inc. AWG 7x0.0 Inc. Individual Shield AL-PES foil, Aluminum contact with stranded tinned copper drain wire General Separator Polyester tape (at least layer) General Drain Wire Solid tinned copper wire AWG 7x Inc. AWG 7x0.0 Inc. General Shield AL-PES foil, Aluminum contact with stranded tinned copper drain wire Sheath Heat resistant and sunlight resistant PVC (UL 5 class 90 C) 00V AWG.3 (.3 Ω/kft) AWG.7 (.95 Ω/kft) AWG 9 mm PVC + 0. mm. Nylon AWG 5.3 mils PVC +.73 mils Nylon 7.5 x Cable diameter Dry 90 C Min. 7% UL 5 (vertical tray), UL 3 (VW-), IEC/EN 033-, IEC (CAT-A), (BS 0 part &3), EN -- ASTM No oil 70 C (ICEA S-73-53) 30

32 3 00V Instrumentation Cables */7 */7 Insulation Thickness Jacket Thickness Nominal O.D. Conductor AWG Pair Number Copper Weight Cable Weight (±0.0) (±0.05)

33 Instrumentation Cables

34 Instrumentation Cables

35 Instrumentation Cables NOTICE M CABLE ensures the accuracy of the all data in this publication, however we cannot be liable for the consequences of errors or omissions. The installer and/or user assumes all liability for the consequences of the installation and/or use of any of our products in contravention of any applicable law, regulation or code.

36 around a world of cables INARI ELECTRICS Madrid. SPAIN info@inarielectrics.com

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line

More information

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology

More information

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum

More information

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary TRAY-RATED CABLE Quick Select Chart 48 TC 600/TC 600 S 50 Flexible Tray Cable with TC-ER for Easier Installations; Unshielded & Shielded TRAY II/TRAY II CY 52 Extremely Oil-Resistant & Flexible Tray Cable

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like

More information

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation

More information

Communication, Control, and Industrial Cable

Communication, Control, and Industrial Cable Communication, Control, and Industrial Cable Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 291 Get control of demanding applications T he broad

More information

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant

More information

Tri-Rated Flexible PVC Equipment Wire

Tri-Rated Flexible PVC Equipment Wire Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier

More information

Instrumentation Cable PLTC/ITC and TC Types

Instrumentation Cable PLTC/ITC and TC Types Instrumentation Cable PLTC/ITC and TC Types The Quality Connection 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for

More information

Multi-Paired Cable Product Finder

Multi-Paired Cable Product Finder Multi-Paired Cable Product Finder Technical Information NO. STRAND TYPE C00 U......................, 0 0 C000 F........................ C0 FB....................... C FB....................... C0 F.......................

More information

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488 ÖLFLEX TRAY II/TRAY II CY Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded ÖLFLEX TRAY II ÖLFLEX TRAY II CY Unshielded Construction : Finely stranded bare copper Jacket:

More information

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships Tray Cable Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for over 35 years, Texcan

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

THHN12STGN500 THHN 12 STR Green 500

THHN12STGN500 THHN 12 STR Green 500 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor

More information

THHN2BK2500 THHN 2 STR Black 2500

THHN2BK2500 THHN 2 STR Black 2500 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Coax (2-1505A Type) 20 AWG BC, GIFPE isulation, Duofoil plus TC braid (95% cv.), PVC inner jackets. Pairs (4-9451 Type): 22 AWG TC, PP insul.,

More information

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry ADC is a proud Sustaining Member of the IMSA organization and is the largest manufacturer in

More information

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors

More information

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN500BK500 THHN 500 STR Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product

More information

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LBK500 THHN 12 Sol Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product

More information

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category THHN6WH500 THHN 6 STR White 500 Southwire Company

More information

SIMpull THHN, it slips and slides - all with NoLube.

SIMpull THHN, it slips and slides - all with NoLube. SOUTHWIRE S SIMpull THHN Southwire maintains its goal of revolutionizing the wire industry by providing its consumers with a product that is not only SIMpull but also requires NoLube. SIMpull THHN is a

More information

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500 Southwire Company Catalog Number Manufacturer Description Weight per

More information

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables CATALOG OF PRODUCTS Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material.

More information

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength thermosetting EPR-based insulation, Type XHHW-2, cabled with bare copper grounding conductors and fillers,

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 24 AWG stranded (7x32) TC conductor, Datalene insulation, pairs individually shielded with bonded Beldfoil with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil

More information

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED ISSUE DATE: 04/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11 Plain Annealed Flexible Copper Conductors / PVC Insulated / Tinned

More information

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Low Voltage AIRGUARD. A proven, rugged product for harsh environments Low Voltage AIRGUARD A proven, rugged product for harsh environments Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Shielded Fire Alarm Cables

Shielded Fire Alarm Cables PLENUM Low-Smoke PVC JACKET UL TYPE FPLP/CMP/CL3P C(UL) CMP 300 VOLT Shielded Fire Alarm Cables Fire Alarm, Signal Monitor/Detection Audio or Control Circuits Description: Chart F, Page 41 Shielded Plenum

More information

DLO Flexible Power Cable

DLO Flexible Power Cable Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics

More information

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39 Product Index SECTION PAGES Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products 0 Power and Control Tray Cable Products 9 Armored Products 0 5 5 Merchandising 5 Technical Information

More information

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic

More information

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C

More information

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010 (0,25mm) XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance

More information

IMSA TRAFFIC SIGNAL CABLE

IMSA TRAFFIC SIGNAL CABLE IMSA TRAFFIC SIGNAL CABLE A tradition of excellence... Exceptional Performance.. is a worldwide leader in the development, design, manufacture, marketing & distribution of wire and cable products. A Broad

More information

Industrial Data Solutions Industrial Ethernet Cables Category 5e DataTuff Twisted Pair Cables Heavy Duty Sunlight- and Oil-Resistant Jackets

Industrial Data Solutions Industrial Ethernet Cables Category 5e DataTuff Twisted Pair Cables Heavy Duty Sunlight- and Oil-Resistant Jackets I N D U S T R I A L C A B L E S 18.7 Cat 5e 24 AWG Bonded-Pair Solid 0.5 Bare Copper Polyethylene Insulation Industrial Grade Sunlight- and Oil-Resistant FRNC /LSNH Jacket (Black and Grey) Diaeter Noinal

More information

MachFlex Industrial Cables

MachFlex Industrial Cables MachFlex Industrial Cables The Ideal Cable Solution for Flex Motion and SpaceConstrained Industrial Applications MachFlex Industrial Cable Table of Contents Description Type Voltage/Resistance Shielding

More information

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG INCH-POUND MIL-DTL-49285/22B 27 March 2018 SUPERSEDING MIL DTL 49285/22A 1 March 2010 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG Inactive

More information

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a. 734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was

More information

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT SouThWire the PeoPLe Southwire started as a small operation in Carrollton, Georgia with 12 employees in 1950. Today, the company employs

More information

Creating. There is one basic question every customer needs to address when creating custom

Creating. There is one basic question every customer needs to address when creating custom Wire and cable have a very deep history in industry, and remain indispensable for a wide variety of applications today. In our current digitized and online landscape, getting the best wire and cable is

More information

Industrial Data. Conductor (stranding) Diameter Nom. DCR. Shielding Materials Nom. DCR. Color Code. (2)18 AWG TC Data Pair:

Industrial Data. Conductor (stranding) Diameter Nom. DCR. Shielding Materials Nom. DCR. Color Code. (2)18 AWG TC Data Pair: INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.22 DeviceBus for VA DeviceNet DeviceNet Counications Rate Table Counications Rate 3082A Maxiu Distance 3082F 3082K 3083A 3084F 3084A/3085A 7895A 7896A

More information

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

Industrial Data Solutions Industrial Data DeviceBus for ODVA DeviceNet Cables

Industrial Data Solutions Industrial Data DeviceBus for ODVA DeviceNet Cables I N D U S T R I A L C A B L E S 18.22 DeviceBus for ODVA DeviceNet Cables 600V Class 1 Thick 15 AWG and 18 AWG Stranded Tinned Copper Beldfoil 18 AWG TC Drain Wire Overall 65% TC Braid PVC /Nylon (Power)

More information

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded

More information

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor Part Number: Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor Product Description Four Cat 6 23 AW G solid bare copper conductors, bonded pair polypropylene insulation,

More information

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4 Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked

More information

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs Republic Wire Inc. began operations in Cincinnati, Ohio in January of 1982. Ron Rosenbeck, owner and president of RWI, has been in the copper industry since 1973. Republic Wire orginally manufactured top-quality

More information

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires

More information

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CUSTOM DESIGN COAXIAL CABLES BY SICAB CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2 Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded

More information

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...

More information

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6 Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6 Lutze Inc 10 South Ridge Dr Charlotte, NC 282 Phone 0-0-0222 Fax 0-0-022 Toll free 1-800--21 www.lutze.com info@lutze.com Lutze Flexible Control

More information

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*) Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX

More information

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from LAPP products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph:(10)358-3130 (800)638-1830 fx:(10)358-312 (800)872-9329 RFQ form: http://mdmetric.com/rfq.htm Flexible Tray

More information

METAL CLAD WIRING SYSTEM

METAL CLAD WIRING SYSTEM METAL CLAD WIRING SYSTEM The Preferred Cable for CLASS I, DIVISION 1 OR ZONE 1 Best Cable for PWM Circuits THE OKONITE COMPANY Ramsey, New Jersey 07446 METAL CLAD WIRING SYSTEM The Preferred Cable for

More information

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

WIRE&CABLE FILS&CÂBLES S I N C E

WIRE&CABLE FILS&CÂBLES S I N C E WIRE&CABLE FILS&CÂBLES 50 CELEBRATING 50+ YEARS S I N C E 1 9 6 0 Dear Friend: Thank you for choosing Provo Ltd. As the leader in providing Canadian industry, coast-to-coast with a full line of electronic

More information

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*) Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX

More information

FieldLink MC at 20 x outer diameter Torsion

FieldLink MC at 20 x outer diameter Torsion Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation

More information

SUPERIOR MARINE CABLE SOLUTIONS

SUPERIOR MARINE CABLE SOLUTIONS SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables

More information

For tough, seaworthy wire

For tough, seaworthy wire Dearborn Marine The Premier Choice for Marine Applications For tough, seaworthy wire and cable, Alpha Wire s Dearborn brand of products delivers performance in the most challenging environments for electrical

More information

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated

More information

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables 5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system

More information

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y

More information

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications... Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control

More information

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

WIRE & CABLE. 99 Wire Low fire hazard wire and cable Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

Industrial Automation & Control Cables

Industrial Automation & Control Cables 6 Industrial Automation & Control Cables Table Contents Introduction 2 Innovcable Data Solutions - Industrial Ethernet 3 Coaxial Cables 3 Innovcable Data Solutions - Industrial Twinax 4 Enerhose Cables

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU New Product Bulletin NP 267 Belden Digital Audio Cable Belden Brilliance AES/EBU Digital Audio Cable, Part No. 1353A, is a robust single-pair Cat 5e patch cord that utilizes Belden s exclusive Bonded-Pair

More information

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction: Caledonian www.caledonian-cables.co.uk www.caledonian-cables.net Profibus L2 Indoor Application: This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the

More information

Content. - DDF Frame Pair Screen Cable Pair Screen Cable

Content. - DDF Frame Pair Screen Cable Pair Screen Cable Content - 120 1.1 Ohm 120ohm DDF DDF Accessories Cables 1.1.1 2 Pair Screen Cable - DDF Frame 1.1.2 4 Pair Screen Cable - 120 Ohm 1.1.3 DDF 8 Pair Cable Screen Cable 1.1.4 16 Pair Screen Cable 1.1.5 50

More information

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables 5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables Applications Three copper conductors cable, each with a semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE

More information

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12-jack to RJ45-plug Ethernet connection line Cat.5, 4-pole, D-coded (IEC

More information

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations 5-35kV MV-105 Power (Tape Shield) 20120124 Description Design Parameters Options Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system consisting of a thermosetting

More information

Selection table for flat & ribbon cables

Selection table for flat & ribbon cables Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Banana Peel Composite - (2) Cat 5e 4-pair 24 AWG unshielded plus (2) Series 6 Coax with Duobond IV Quad shield, polyolefin insulation on the

More information

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective

More information

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no) GameChanger Cable Unshielded Twisted Pair Riser Rated - CMR 258310333 46224PRYWB (legacy part no) 1.0 Scope 1.1 This cable consists of 4 pair solid bare copper; color-coded high density polyethylene (HDPE)

More information

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation

More information

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09) KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications

More information

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded

More information

AEE. Canada. Australia

AEE. Canada. Australia DMARCA DE CONFORMIDA CORDS & ELECTRICAL UNIVERSAL POWER JUMPER CORD INTERNATIONAL AGENCIES APPROVED 302 POWER JUMPER CORD APPLICATIONS: To Connect Accessories and Peripherals to Computers and Electronic

More information

Servo Cable Selection

Servo Cable Selection Servo Cables Servo Cable Selection Chainflex cable Jacket Shield Class Bending radius moving (factor x d) Temperature moving from/to F ( C) Oil-resistant V max. ft/s (m/s) unsupported V max. ft/s (m/s)

More information

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties 2. CONDUCTORS 2.1 Strand Types 2.1.1 Concentric Strand 7 2.1.2 Bunch Strand 7 2.1.3 Rope Strand 8 2.1.4 Sector Conductor 8 2.1.5 Segmental Conductor 8 2.1.6 Annular Conductor 8 2.1.7 Compact Strand 8 2.1.8

More information

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable.   Features & Benefits Dual Wall 20ºC rated, Modified Polyester 99 wire has a dual wall construction of radiation crosslinked modified polyester. This combines excellent mechanical performance and chemical resistance with a

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. For more information please call 1-800-Belden1 See Put-ups and Colors Description:

More information

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery Bulletin OSC OKONITE CABES STOCK CATAOG In Stock for Immediate Delivery THE OKONITE COMPANY 0 Hilltop Road, Ramsey, New Jersey 07 Phone.8.000 www.okonite.com INDEX Data Sheet Section:Sheet GOSSARY OF TERMS

More information