DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Size: px
Start display at page:

Download "DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES"

Transcription

1 DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

2 DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like Type MC. CIR has been successfully used globally since 00 for missioncritical equipment operating in harsh environments. CIR passes the same crush and impact testing required by UL 5 for Type MC-HL without the use of external armoring. CIR cables are GEXOL insulated which provides a lower dielectric constant, allowing longer VFD output cable lengths. Highly flexible, small bend radius, reduced tray fill and impervious to water and air. UL Listed as Type TC-ER (Standard CIR) suitable for a variety of uses, including those where tray cables are not practical or costprohibitive. UL Listed as Type TC-ER-HL (Arctic Grade CIR) suitable for a variety of uses in Class, Div and Zone environments including those where tray cables are not practical or cost-prohibitive. (Cables up to in diameter) See pages - VFD Cables Nexans AmerCable VFD Cables are specially engineered to provide 00% containment of EMI emissions and provide longer cable life in VFD applications. Nexans AmerCable VFD cables feature symmetrical insulated ground conductors that reduce induced voltage imbalances and carry common mode noise back to the drive. Nexans AmerCable s high strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. Available in 5 constructions. See pages -0 Nexans AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listed is approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application.

3 Type MMV (Medium Voltage) Power Type MMV cables are designed for use as feeders or branch circuits in industrial facilities. These cables utilize flexible stranded conductors, braided shields and a braided armor (optional) which make them very suitable for applications involving repeated flexing and high vibration These cables have a small minimum bending radius for easy installation. See pages - CORFLEX Cables CORFLEX cables are designed for reliable performance in a variety of oil and gas downstream, industrial, commercial and utility applications which require an externally armored cable. Nexans CORFLEX MC-HL and MV-05 or MC-HL cables can be installed in hazardous locations designated Class I, II & III, Divisions & as per NEC 008 and NEC 0 (HL Rated). See pages -5 RHH or RHW- Cables Nexans AmerCable s 000V Diesel Locomotive Cable (DLO) is a single conductor portable power cable suitable for use in applications needing great flexibility, excellent wearability and good flex life. See pages -7 AmerCable and GEXOL are registered trademarks of AmerCable Incorporated. CORFLEX is a registered trademark of Nexans

4 7-0 CIR STANDARD CIR POWER CABLE UL LISTED AS TYPE TC-ER Three & Four Conductor + Ground Gexol Insulated 0./kV MSHA Approved Rated 90 C GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 80 and Type X0 of UL 9/CSA 5. 00V/IEC 000V. Safer to Handle CIR has no sharp metal armor edges that imperil worker s hands during splicing and installation of connectors See Bend Radius on Page Conductor Soft annealed flexible stranded tinned copper per IEEE 80 Table. A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoplastic compound meeting UL 9/ CSA 5 and IEEE 80. APPLICATION Designed and constructed to be a flexible alternative to Type MC cable where user desires the added crush and impact protection. FEATURES n MSHA approved ( & conductor cables)) n Passes the same stringent crush and impact testing required by UL 5 for Type MC-HL n Gas & vapor tight impervious to water and air n Smaller bend radius (up to 0% smaller) than Type MC n Reduced tray fill (up to 5% less) compared to Type MC n Considerably more flexible than Type MC n Reduced installation time and cost compared to Type MC n Glands for this product cost up to % LESS than those for Type MC Standard CIR Ratings & Approvals n 90 C temperature rating n UL Listed as Type TC-ER (E9) n MSHA Approved ( & conductor cables) n UL Listed as Marine Shipboard Cable (E) n American Bureau of Shipping (ABS) n Flame Retardant IEEE 0 n Suitable for use in Class I, Div and Zone environments n Sunlight resistant n Direct burial downstream@nexans.com

5 Conductor Size Grounding Nominal DC Resistance AC Resistance Inductive Voltage Drop AWG/ Number of Conductor Part No. Diameter Weight 90 C NEC 75 C NEC at 5 C at 90 C, 0Hz Reactance (Volts/Amp/ kcmil mm Conductors AWG/kcmil 7-0 (inches) (lbs/000 ft.) Ampacity Ampacity Ampacity (ohms/000 ft.) (ohms/000 ft.) 000 ft.). -8CIRG CIRG CIRG CIRG CIRG CIRG CIRG CIRG CIRG CIRG CIRG CIRG CIRG CIRG /0 5 -CIRG /0 5 -CIRG /0 70-7CIRG /0 70-7CIRG /0 09-9CIRG /0 09-9CIRG CIRG CIRG CIRG CIRG CIRG CIRG CIRG CIRG Ampacities are based on Table 0. (B) () of the National Electrical Code (NEC) for conductors rated 90 C, in a multi-conductor cable, at an ambient temperature of C. The 75 C column is provided for additional information. The ampacities shown apply to open runs of cable, installation in any approved raceway. Derating for more than three current carrying conductors within the cable is in accordance with NEC Table 0. (B) () (a). The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section For Cable Color Codes and Stranding Information See page Manufactured by Nexans AmerCable Fax:

6 7-0 CIR STANDARD CIR CONTROL CABLE UL LISTED AS TYPE TC-ER Multi-Conductor Gexol Insulated 0./kV Rated 90 C GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 80 and Type X0 of UL 9/CSA 5. 00V/IEC 000V. For Cable Color Codes and Stranding Information see page Safer to Handle CIR has no sharp metal armor edges that imperil worker s hands during splicing and installation of connectors Gexol and CIR are registered trademarks of AmerCable Incorporated. Conductor Soft annealed flexible stranded tinned copper per IEEE 80 Table. See Page for Standard CIR Ratings & Approvals A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoplastic compound meeting UL 9/CSA 5 and IEEE 80. Rated for direct burial. APPLICATION Designed and constructed to be a flexible alternative to Type MC cable where user desires the added crush and impact protection. FEATURES n Passes the same stringent crush and impact testing required by UL 5 for Type MC-HL n Gas & vapor tight impervious to water & air n Smaller bend radius (up to 0% smaller) than Type MC n Reduced tray fill (up to 5% less) compared to Type MC n Considerably more flexible than Type MC n Reduced installation time and cost compared to Type MC n Glands for this product cost up to % LESS than those for Type MC Conductor Size Nominal Weight DC Resistance AC Resistance Voltage Drop Number of Part No. Diameter (lbs/ 90 C NEC 75 C NEC at 5 C at 90 C, 0Hz (Volts/Amp/ AWG mm Conductors 7-0 (inches) 000 ft.) Ampacity Ampacity (ohms/000 ft.) (ohms/000 ft.) 000 ft.). -8CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR Ampacities are based on Table 0. (B) () of the National Electrical Code (NEC) for conductors rated 90 C, in a multi-conductor cable, at an ambient temperature of C. The 75 C column is provided for additional information. The ampacities shown apply to open runs of cable, installation in any approved raceway. Derating for more than three current carrying conductors within the cable is in accordance with NEC Table 0. (B) () (a). The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section downstream@nexans.com

7 7-0 CIR STANDARD CIR INSTRUMENTATION CABLE UL LISTED AS TYPE TC-ER Individually Shielded Pairs/Triads Gexol Insulated 0./kV Rated 90 C GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 80 and Type X0 of UL 9/CSA 5. 00V/IEC 000V. Safer to Handle CIR has no sharp metal armor edges that imperil worker s hands during splicing and installation of connectors See Page for Standard CIR Ratings & Approvals For Cable Color Codes and Stranding Information See page See Bend Radius on Page Conductor Soft annealed flexible stranded tinned copper per IEEE 80 Table. Pairs/ Triads Each pair/triad is twisted with a bare tinned drain wire. Each pair/triad is shielded with polyesterbacked aluminum foil tape to afford 00% coverage. Pair to pair, or triad to triad, isolation plus overall shielding is provided. A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoplastic compound meeting UL 9/CSA 5 and IEEE 80.Rated for direct burial. APPLICATION Designed and constructed to be a flexible alternative to Type MC cable where user desires the added crush and impact protection. FEATURES n Passes the same stringent crush and impact testing required by UL 5 for Type MC-HL n Gas & vapor tight impervious to water & air n Smaller bend radius (up to 0% smaller) than Type MC n Reduced tray fill (up to 5% less) compared to Type MC n Considerably more flexible than Type MC n Reduced installation time and cost compared to Type MC n Glands for this product cost up to % LESS than those for Type MC Conductor Nominal DC Resistance Mutual Size Part No. Diameter Weight 0 C Capacitance Inductance AWG mm Pairs Triads 7-0 (inches) (lbs/000 ft.) (ohms/000 ft.) (nf/000 ft.) (mh/000 ft.). -0CIR CIR CIR CIR CIR CIR CIR CIR CIR CIR VALUES: # Pairs / Triads Capacitance nf/000 feet = Inductance mh/000 = 0.0 Resistance Ohms/000 feet =.5 (@ 0 C) Gexol and CIR are registered trademarks of AmerCable Incorporated. Manufactured by Nexans AmerCable Fax:

8 7-0 CIRVFD CIR (CRUSH & IMPACT RESISTANT) VFD POWER CABLE UL LISTED AS TYPE TC-ER Three Conductor Gexol Insulated kv Rated 90 C APPLICATION A flexible, braid and foil shielded, kv power cable specifically engineered for use in variable Power Conductors (x) Soft annealed flexible stranded tinned copper per ASTM B-. (kv) Gexol cross-linked flame retardant polyolefin, meeting the requirements for Type RHW. Color: Gray with printed phase I.D. (Black- Red-Blue) A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoplastic compound meeting UL 77. CIR VFD Ratings & Approvals n 90 C temperature rating n UL Listed as Type TC-ER (E9) n Flame Retardant IEEE 0/FT- n Sunlight resistant n Direct burial Ground Conductors (x) Soft annealed tinned copper per ASTM B- flexible stranding with 00/000V Gexol insulation sized per UL 77. Color: Green Shield Overall tinned copper braid plus aluminum/polyester tape providing 00% coverage. Safe to Handle CIR is a safe, flexible alternative to metal-clad cables. Also available in Arctic Grade: Rated TC-ER-HL for cable diameters up to Gexol and CIR are registered trademarks of AmerCable Incorporated frequency AC motor drive (VFD) applications. FEATURES n Specially engineered cable design produces a longer cable life in VFD applications. n Overall braid plus foil shield is engineered with 00% coverage and a surface transfer impedance < milliohms at 0MHz to contain EMI. n Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. n High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. n Gexol s lower dielectric constant (standard XLPEs, EPRs and other Type RHW insulation materials have higher dielectric constants) reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system. n kv insulation thickness is used to resist the potential -x reflected voltages experienced in 00V VFD applications. n Passes the same stringent crush and impact testing required by UL 5 for Type MC-HL n Gas & vapor tight impervious to water and air n Smaller bend radius (up to 0% smaller) than Type MC n Reduced tray fill (up to 5% less) compared to Type MC n Considerably more flexible than Type MC n Reduced installation time and cost compared to Type MC n Glands for this product cost up to % LESS than those for Type MC downstream@nexans.com

9 7-0 CIR VFD 000 VOLTS CRUSH & IMPACT RESISTANT DC Resist. AC Resist. Inductive Green NEC Ampacities Size Nominal 5 90 C, 0 Hz Reactance Voltage Drop Insulated In Single In AWG/ Six Part No. Diameter (Lbs./ (Ohms/ (Ohms/ (Ohms/ (Volts/Amp/ Grounding* Free Air Tray Conduit kcmil mm 7-0 Inches* 000 Ft.) 000 Ft.) 000 Ft.) 000 Ft.) 000 Ft.) (x) (AWG) 90 C 75 C 90 C 75 C 90 C 75 C. -8CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD /0 5 -CIRVFD /0 70-7CIRVFD /0 09-9CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD CIRVFD Cable diameters are subject to a +/- 5% manufacturing tolerance Ampacity In Free Air: Based on 90 C conductor temperature and C ambient temperature per 0 NEC Table B.0.(B)()() Ampacity In Cable Tray: Based on 90 C conductor temperature and C ambient temperature per 0 NEC Table 0.(B)() Ampacity In Raceway Based on 90 C conductor temperature and C ambient temperature per 0 NEC Table B.0.(B)()() * Grounding Conductors Green Insulated NEC ampacities are based on Table 0.(B)() of the National Electrical Code (NEC) for conductors rate 90 C, in a multi-conductor cable, at an ambient temperature of C. The 75 C column is provided for additional information. The ampacities shown apply to open runs of cable, installation in any approved raceway. Derating for more than three current carrying conductors within the cable is in accordance with NEC Table 0.(B)()(a). The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section CIR VFD Stranding Profile Closest Equivalent Uninsulated Size Number IEEE 5 Metric Size Conductor AWG/kcmil of Strands Std. Size (mm) Dia. (inches) 0 8 /0 /0 /0 / Manufactured by Nexans AmerCable Fax:

10 7-0 CIRGAG ARCTIC GRADE CIR POWER CABLE TYPE TC-ER-HL* Three & Four Conductor + Ground Gexol Insulated 0./kV Rated 90 C GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 80 and Type X0 of UL 9/CSA 5. 00V/IEC 000V. Safer to Handle CIR has no sharp metal armor edges that imperil worker s hands during splicing and installation of connectors Conductor Soft annealed flexible stranded tinned copper per IEEE 80 Table. Brittlepoint as per ASTM D 7-07 exceeds -5 C for and -75 C for A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 9/ CSA 5 and IEEE 80. See Bend Radius on Page APPLICATION Designed and constructed to be a flexible alternative to Type MC cable where user desires crush and impact protection in arctic conditions. FEATURES n Complies with the requirements for TC-ER-HL per UL 5* n Exceeds CSA cold bend / cold impact (-0 C / -5 C) n Gas & vapor tight impervious to water and air n Smaller bend radius (up to 0% smaller) than Type MC n Reduced tray fill (up to 5% less) compared to Type MC n Considerably more flexible than Type MC n Reduced installation time and cost compared to Type MC n Glands for this product cost up to % LESS than those for Type MC *cables up to in diameter CIR Arctic Grade Ratings & Approvals n 90 C temperature rating n UL Listed as Marine Shipboard Cable (E) n UL Listed as Type TC-ER n UL Listed as TC-ER-HL* n American Bureau of Shipping (ABS) n Flame Retardant IEEE 0 n Suitable for use in Class I, Div and Zone environments n Suitable for Class, Div and Zone environments* *Cables up to in diameter Gexol and CIR are registered trademarks of AmerCable Incorporated downstream@nexans.com

11 Conductor Size Grounding Nominal DC Resistance AC Resistance Inductive Voltage Drop AWG/ Number of Conductor Part No. Diameter Weight 90 C NEC 75 C NEC at 5 C at 90 C, 0Hz Reactance (Volts/Amp/ kcmil mm Conductors AWG/kcmil 7-0* (inches) (lbs/000 ft.) Ampacity Ampacity Ampacity (ohms/000 ft.) (ohms/000 ft.) 000 ft.). -8CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG /0 5 -CIRGAG /0 5 -CIRGAG /0 70-7CIRGAG /0 70-7CIRGAG /0 09-9CIRGAG /0 09-9CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG Ampacities are based on Table 0. of the National Electrical Code (NEC) for conductors rate 90 C, in a multi-conductor cable, at an ambient temperature of C. The 75 C column is provided for additional information. The ampacities shown apply to open runs of cable, installation in any approved raceway. Derating for more than three current carrying conductors within the cable is in accordance with NEC Table 0. (B) () (a). The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section 9.. For Cable Color Codes and Stranding Information See page Hawke Gland Types Hawke Gland Types Type CIR Industrial & Safe Area (IP8) Increased Safety EExe / Explosion Proof 70 Class I, Div. Class I, Zone & Flameproof / EExd Zone & Manufactured by Nexans AmerCable Fax:

12 7-0 CIRGAG ARCTIC GRADE CIR CONTROL CABLE TYPE TC-ER-HL* Multi-Conductor Gexol Insulated 0./kV Rated 90 C GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 80 and Type X0 of UL 9/CSA 5. 00V/IEC 000V. For Cable Color Codes and Stranding Information, see page. Safe to Handle CIR has no sharp metal armor edges that imperil worker s hands during splicing and installation of connectors 0 Conductor Soft annealed flexible stranded tinned copper per IEEE 80 Table. Ground Brittlepoint as per ASTM D 7-07 exceeds -5 C for and -75 C for A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 9/CSA 5 and IEEE 80. See page 8 for Arctic CIR Ratings & Approvals APPLICATION Designed and constructed to be a flexible alternative to Type MC cable where user desires crush and impact protection in arctic conditions. FEATURES n Complies with the requirements for TC-ER-HL per UL 5* n Exceeds CSA cold bend / cold impact (-0 C / -5 C) n Gas & vapor tight impervious to water & air n Smaller bend radius (up to 0% smaller) than Type MC n Reduced tray fill (up to 5% less) compared to Type MC n Considerably more flexible than Type MC n Reduced installation time and cost compared to Type MC n Glands for this product cost up to % LESS than those for Type MC Conductor Size Ground DC Resistance AC Resistance Voltage Drop Number of Part No. Diameter Weight 90 C NEC 75 C NEC at 5 C at 90 C, 0Hz (Volts/Amp/ AWG mm Conductors 7-0* Number AWG (inches) (lbs/000 ft.) Ampacity Ampacity (ohms/000 ft.) (ohms/000 ft.) 000 ft.). -7CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG CIRGAG Ampacities are based on Table 0. of the National Electrical Code (NEC) for conductors rate 90 C, in a multi-conductor cable, at an ambient temperature of C. The 75 C column is provided for additional information. The ampacities shown apply to open runs of cable, installation in any approved raceway. Derating for more than three current carrying conductors within the cable is in accordance with NEC Table 0. (B) () (a). The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section 9.. *cables up to in diameter)

13 7-0 CIRAG ARCTIC GRADE CIR INSTRUMENTATION CABLE TYPE TC-ER-HL* Individually Shielded Pairs/Triads Gexol Insulated 0./kV Rated 90 C GEXOL cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 80 and Type X0 of UL 9/CSA 5. 00V/IEC 000V. Safer to Handle CIR has no sharp metal armor edges that imperil worker s hands during splicing and installation of connectors Brittlepoint as per ASTM D 7-07 exceeds -5 C for and -75 C for For Cable Color Codes and Stranding Information See page See page 8 for Arctic Grade CIR Ratings & Approvals Conductor Soft annealed flexible stranded tinned copper per IEEE 80 Table. Pairs/ Triads Each pair/triad is twisted with a bare tinned drain wire. Each pair/triad is shielded with polyester-backed aluminum foil tape to afford 00% coverage. Pair to pair, or triad to triad, isolation plus overall shielding is provided. A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 9/ CSA 5 and IEEE 80. APPLICATION Designed and constructed to be a flexible alternative to Type MC cable where user desires crush and impact protection in arctic conditions. FEATURES n Complies with the requirements for TC-ER-HL per UL 5* n Exceeds CSA cold bend / cold impact (-0 C / -5 C) n Gas & vapor tight impervious to water & air n Smaller bend radius (up to 0% smaller) than Type MC n Reduced tray fill (up to 5% less) compared to Type MC n Considerably more flexible than Type MC n Reduced installation time and cost compared to Type MC n Glands for this product cost up to % LESS than those for Type MC *cables up to in diameter Conductor Nominal DC Resistance Mutual Size Part No. Diameter Weight 0 C Capacitance Inductance AWG mm Pairs Triads 7-0* (inches) (lbs/000 ft.) (ohms/000 ft.) (nf/000 ft.) (mh/000 ft.). -0CIRAG CIRAG CIRAG CIRAG CIRAG CIRAG CIRAG CIRAG CIRAG CIRAG VALUES: # Pairs / Triads See Bend Radius on Page Capacitance nf/000 feet = Inductance mh/000 = 0.0 Resistance Ohms/000 feet =.5 (@ 0 C) Manufactured by Nexans AmerCable Fax:

14 7-0 CIRVFD ARCTIC GRADE STANDARD CIR UL LISTED AS TYPE TC-ER-HL* Three Conductor Gexol Insulated kv Rated 90 C TYPE VFD Power Conductors (x) Soft annealed flexible stranded tinned copper per UL. (kv) Gexol cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 80 and Type X0 of UL 9/CSA 5. Color: Gray with printed phase I.D. (Black- Red-Blue) A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset CPE meeting UL 77. CIR Ratings & Approvals Ground Conductors (x) Soft annealed flexible stranded tinned copper per UL. Gexol insulation sized per UL 77. Color: Green Shield Overall tinned copper braid plus aluminum/polyester tape providing 00% coverage. Safer to Handle CIR has no sharp metal armor edges that imperil worker s hands during splicing and installation of connectors n 90 C temperature rating n UL Listed as Type TC-ER (E9) n UL Listed as TC-ER-HL (cables up to in diameter) n Flame Retardant IEEE 0 n Suitable for use in Class I, Div and Zone environments n Suitable for Class, Div and Zone environments (cables up to in diameter) *Cables up to in diameter APPLICATION A flexible, braid and foil shielded, kv power cable specifically engineered for use in variable frequency AC motor drive (VFD) applications. FEATURES Specially engineered cable design produces a longer cable life in VFD applications in severe cold environments. Exceeds CSA cold bend/cold impact (-0 C/-5 F) Brittlepoint as per ASTM D 7-07 exceeds -5 C for and -75 C for insulation Overall braid and foil shield provides 00% coverage containing VFD EMI emissions. Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. Gexol s lower dielectric constant (standard XLPEs, EPRs and other Type RHW insulation materials have higher dielectric constants) reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system. kv insulation thickness resists the repetitive x voltage spikes from 00V VFDs and reduces drive over current trip problems due to cable charging current. Passes the same stringent crush and impact testing required by UL 5 for Type MC-HL Gas & vapor tight impervious to water and air Smaller bend radius (up to 0% smaller) than Type MC Reduced tray fill compared to Type MC Considerably more flexible than Type MC Reduced installation time and cost Glands cost up to % less downstream@nexans.com

15 DC Resist. AC Resist. Inductive Green NEC Ampacities Size Nominal 5 90 C, 0 Hz Reactance Voltage Drop Insulated In Single In AWG/ Size Part No. Diameter (Lbs./ (Ohms/ (Ohms/ (Ohms/ (Volts/Amp/ Grounding* Free Air Tray Conduit kcmil mm 7-0 Inches* 000 Ft.) 000 Ft.) 000 Ft.) 000 Ft.) 000 Ft.) (x) (AWG) 90 C 75 C 90 C 75 C 90 C 75 C. -8CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA /0 5 -CIRVFDA /0 70-7CIRVFDA /0 09-9CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA CIRVFDA *Cable diameters are subject to a +/- 5% manufacturing tolerance Ampacities are based on Table 0.(B)() of the National Electrical Code (NEC) for conductors rated 90 C, in a multi-conductor cable, at an ambient temperature of C. The 75 C column is provided for additional information. The ampacities shown apply to open runs of cable, installation in any approved raceway. Derating for more than three current carrying conductors within the cable is in accordance with NEC Table 0.(B)()(a). The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section Gexol and CIR are registered trademarks of AmerCable Incorporated Manufactured by Nexans AmerCable Fax:

16 Control Cables Colored Conductor #Base ColorTracer Color Black Red Blue Orange 5 Yellow Brown 7 Red Black 8 Blue Black 9 Orange Black 0 Yellow Black Brown Black Black Red Blue Red Orange Red Yellow Red Brown Red 7 Black Blue 8 Red Blue 9 Orange Blue 0 Yellow Blue Brown Blue Black Orange Red Orange Blue Orange 5 Yellow Orange Brown Orange 7 Black Yellow 8 Red Yellow 9 Blue Yellow Orange Yellow Brown Yellow Black Brown Red Brown Blue Brown 5 Orange Brown Yellow Brown 7 Black Power Cables AWG and smaller = colored insulation AWG and larger = print Conductor # Size AWG/kcmil 0 8 /0 /0 /0 0 7 Color Black Red Blue Orange No. of Strands Instrumentation Cables Pairs Triads CIR Stranding Profiles Closest IEEE 5 Standard Size Black, White Black, White, Red Pair / Triad number printed on conductors Equivalent Metric Size (mm) Uninsulated Conductor Dia. (Inches) downstream@nexans.com

17 The True Cable Cost Comparison: Lower Total Installed Cost AmerCable CIR vs. Type CWCMC (MC-HL) Based on 00 ft. of cable, glands and installation labor (cable & glands) AWG Shielded Pair CIR Saves you % AWG /C+G CIR Saves you 7% AWG /C+G CIR Saves you 8% AWG /C+G CIR Saves you % /0 /C+G CIR Saves you 0% Glands for CIR Cables cost up to % LESS than those for Type MC Data Basis:. Labor rate $5.00/hr.. Labor time quotes based on long established Fluor Daniel Project Controls Standard Unit for Type TC and Type CWCMC cables for installation tray.. Identical installation for both products using a 00 ft. run basis.. Hawke A series glands used for CIR cables and Hawke N70 glands used for Type CWCMC cables. 5. MRO pricing is used for cables and glands. Bend Radius Type CIR IEEE 5 X Diameter NEC < " (5mm) X Diameter > " (5mm) < " (mm) 5X Diameter > " (mm) X Diameter Manufactured by Nexans AmerCable Fax:

18 7-0VFD EXTRA FLEXIBLE VFD POWER CABLE GEXOL INSULATED Three Conductor kv Rated 90 C Power Conductors (x) Soft annealed flexible stranded tinned copper per IEEE and UL. (kv) Gexol cross-linked flame retardant polyolefin, meeting the requirements for Type RHW. A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 77. Ratings & Approvals n 90 C Temperature Rating n UL Listed as Type TC-ER (E9) n Flame resistance: IEEE 0/FT- n Sunlight resistant Ground Conductors (x) Soft annealed flexible stranded tinned copper per IEEE 80 Table. Gexol insulated and sized per UL 77. Color: Green Shield Overall tinned copper braid plus aluminum/polyester tape providing 00% coverage. APPLICATION A flexible, braid and foil shielded, kv power cable specifically engineered for use in variable frequency AC motor drive (VFD) applications. FEATURES n Specially engineered cable design produces a longer cable life in VFD applications. n Overall braid plus foil shield is engineered with 00% coverage and a surface transfer impedance < milliohms at 0MHz to contain EMI. n Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. n High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. n Gexol s lower dielectric constant (standard XLPEs, EPRs and other Type RHW insulation materials have higher dielectric constants) reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system. n kv insulation thickness is used to resist the potential -x reflected voltages experienced in 00V VFD applications. n Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-5 C). n Flame retardant: IEC - Category A and IEEE 0. Gexol is a registered trademark of AmerCable Incorporated downstream@nexans.com

19 7-0VFD EXTRA FLEXIBLE VFD POWER CABLE GEXOL INSULATED DC Resist. AC Resist. Inductive Green NEC Ampacities Size Nominal 5 90 C, 0 Hz Reactance Voltage Drop Insulated In Single In AWG/ Size Part No. Diameter (Lbs./ (Ohms/ (Ohms/ (Ohms/ (Volts/Amp/ Grounding* Free Air Tray Conduit kcmil mm 7-0 Inches* 000 Ft.) 000 Ft.) 000 Ft.) 000 Ft.) 000 Ft.) (x) (AWG) 90 C 75 C 90 C 75 C 90 C 75 C -VFD VFD VFD /0 5 -VFD /0 70-7VFD /0 09-9VFD VFD VFD VFD VFD VFD VFD VFD VFD VFD VFD VFD Cable diameters are subject to a +/- 5% manufacturing tolerance Ampacity In Free Air: Based on 90 C conductor temperature and C ambient temperature per 0 NEC Table B.0.(B)()() Ampacity In Cable Tray: Based on 90 C conductor temperature and C ambient temperature per 0 NEC Table 0.(B)() Ampacity In Raceway Based on 90 C conductor temperature and C ambient temperature per 0 NEC Table B.0.(B)()() * Grounding Conductors Green Insulated Manufactured by Nexans AmerCable Fax:

20 7-08VFD FLEXIBLE TC-ER VFD POWER CABLE Three Conductor 90 C 000V* Power Conductors (x) Soft annealed flexible stranded tinned copper per ASTM B- Cross-linked, flexible, low dielectric constant compound rated 90 C. Sizes larger than /0 AWG individual conductors colored black with conductor number surface printed in contrasting ink. Sizes /0 AWG and smaller individually colored conductors red, white,black. Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC). Colored black. Symmetrical Ground Conductors (x) Three symmetrically placed flexible stranded tinned copper conductors in direct contact with the shield. Metallic Shield Sizes 8 AWG and Larger Helically applied bare copper tape. Sizes Smaller than 8 AWG tin-coated copper braid plus aluminum/polyester tape. Both shielding systems provide 00% coverage. TC-ER Ratings & Approvals * n UL Listed as Type TC-ER 00V * n UL Listed as 000V flexible motor supply cable (up to /0 AWG) n 90 C Temperature Rating n FT- and IEEE 0 flame ratings n Sunlight resistant n Direct burial APPLICATION A flexible, shielded power cable specifically engineered for use in variable frequency AC motor drive (VFD) applications. FEATURES n Specially engineered cable design produces a longer cable life in VFD applications. n Overall shield provides 00% coverage containing VFD EMI emissions. n Symmetrical ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. n High strand count design is much more flexible, easier to install and more resistant to vibration than Type MC cable. n Meets crush and impact requirements for Type MC cable. n AmerCable s specially formulated insulation material has a lower dielectric constant (standard XLPE and EPR insulation materials have higher dielectric constants) which withstands reflected voltages. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system. n Permitted for Exposed Run ( ER ) use in accordance with the NEC. n Permitted for use in Class I, Division and Zone industrial hazardous locations per the NEC. n Gas and vapor tight impervious to water and air. n Reduced tray fill (up to 5% less) than Type MC. n Reduced installation time and cost compared to Type MC. n Glands for this product cost up to % LESS than those for Type MC. n Bend radius X O.D downstream@nexans.com

21 7-08 VFD FLEXIBLE TC-ER VFD 000 VOLTS DC Resist. AC Resist. Inductive Green NEC Ampacities Size Nominal 5 90 C, 0 Hz Reactance Voltage Drop Insulated In Single In AWG/ Size Part No. Diameter (Lbs./ (Ohms/ (Ohms/ (Ohms/ (Volts/Amp/ Grounding* Free Air Tray Conduit kcmil mm 7-0 Inches* 000 Ft.) 000 Ft.) 000 Ft.) 000 Ft.) 000 Ft.) (x) (AWG) 90 C 75 C 90 C 75 C 90 C 75 C. -8VFD VFD VFD VFD VFD VFD VFD VFD /0 -VFD /0-7VFD /0 95-9VFD VFD VFD VFD VFD VFD VFD VFD VFD VFD VFD VFD Cable diameters are subject to a +/- 5% manufacturing tolerance Ampacity In Free Air: Based on 90 C conductor temperature and C ambient temperature per 0 NEC Table B.0.(B)()() Ampacity In Cable Tray: Based on 90 C conductor temperature and C ambient temperature per 0 NEC Table 0.(B)() Ampacity In Conduit: Based on 90 C conductor temperature and C ambient temperature per 0 NEC Table B.0.(B)()() Equivalent Uninsulated Size Number Metric Size Conductor AWG/kcmil of Strands (mm) Dia. (inches) 0 8 /0 /0 / Stranding Profile Manufactured by Nexans AmerCable Fax:

22 CABLE SELECTION GUIDE FOR VFD APPLICATIONS The circuit of a typical voltage source PWM drive is shown in Figure. Each part of the equipment is bonded to the safety earth system to ensure personnel safety if faults occur. All parts have capacitance to ground shown by: CM for the motor windings. CC and CC for the power converter circuits. CT for the transformer s secondary winding to the transformers screen. The IGBT switches are in constant operation at high frequency and this produces an inverter output voltage with a PWM wave shape as shown by the voltage V(Figure ). This IGBT switches also cause a motor line to ground voltage V (Figure ), normally called a common mode voltage. The common mode voltages cause short high-frequency pulses of common mode current to flow in the safety earth circuits, shown by currents I and I (Figure ), unless the design includes cable features to stop this from happening. It is essential that the common mode currents return to the inverter without causing EMC - EMI problems in other equipment, and this means that the common mode currents I and I must not flow in the safety earthing system. For the motor, this is achieved by connecting a set of wires from the motor to the inverter that run with the main power cables. These are called symmetrical grounding conductors, see Figure. These conductors have a very low impedance compared with the other return path via the safety earthing system. The three symmetrical grounding conductors and overall shields are connected as shown in Figure. This 0 connection is essential. The common mode currents I and I now flow in the symmetrical grounding conductors. This happens because the symmetrical grounding conductors are close to the power conductors giving a low impedance route for the currents I and I compared with the safety earthing system. As I and I flow near the power conductors this avoids creating external EMC - EMI problems. F I G U R E Figures - courtesy of Converteam 0 Manufactured by Nexans AmerCable (870) 8-99 (800) - Fax (870) 8-9

23 If symmetrical grounding conductors and an overall EMI shield are not used, EMC - EMI problems are very likely to occur. For cables used with voltage source PWM drives, a number of features are required to ensure correct operation, avoid overheating and achieve longer service life. The essential features of a medium voltage cable for PWM drives are : F I G U R E designed to withstand the transients produced by the PWM with a dielectric constant no greater than.0 to minimize capacitance Voltage rating of x the operating voltage to prevent corona Three symmetrical grounding conductors. Some cables only have one grounding conductor. This is not acceptable as it produces circulating currents in the earth system Extremely fine strands to carry the harmonic currents without overheating (i.e. the inductance of fine stranded conductors is less than 7, 9, 7 strand conductors) Overall shield to stop the radiation of voltage EMI fields Correct termination at both ends Semi-conducting shield around each insulation layer (MMV only) Metallic layer around each semi-conducting shield to earth the semi-conducting shield (MMV only) Low-Smoke Halogen-Free and Fire Resistant constructions available. Contact your Nexans AmerCable rep. industrial@nexansamercable.com

24 7-05 TYPE MMV MEDIUM POWER CABLE (MV-05) Single Conductor: 5kV kv, 00% & % Levels. Rated 05 C Conductor Soft annealed flexible stranded tinned copper per IEEE 80 Table. Extruded thermosetting 05 C Ethylene Propylene Rubber (EPR), meeting UL 07. Metallic Shield Composite shield consisting of 0.0" tinned copper braided with nylon providing 0% copper shielded coverage meeting UL 07. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need to remove the shield to find an underlying colored tape. Ratings & Approvals UL Listed as Medium Voltage Cable (E) Flame retardance: IEEE 0 & IEC 0 Sunlight Resistant Cable Tray Use (Sizes /0 AWG and larger) 05 C Temperature Rating Voltage Rating 5kV to kv (5kV available on request) Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 07. Shield Semi-conducting tape, with overlap, for fast and easy termination meeting UL 07. A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 07. Colored jackets for signifying different voltage levels are also available on special request (ie. yellow = 5kV, orange = 8kV and red = kv). Armor (optional) 0.0" bronze braid providing 88% minimum coverage. Sheath (optional) A black, arctic grade, flame retardant, oil, abrasion, chemical, and sunlight resistant thermosetting compound meeting UL 07. Colored jackets for signifying different voltage levels is also available on special request (ie. yellow = 5kV, orange = 8kV and red = kv). APPLICATIONS Nexans AmerCable medium voltage power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations. Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section.(A)(5), or messenger supported in industrial establishments and electric utilities. FEATURES n These cables utilize flexible stranded conductors, braided shields and a braided armor (when armored) which make them very suitable for applications involving repeated flexing and high vibration. n These cables have a small minimum bending radius (xod for unarmored cables and 8xOD for armored cables) for easy installation. n Optional uninsulated grounding conductors sized per UL 07. n The increased flexibility of this cable allows for faster installation times. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) -X Increased Safety EExe / /5/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof / /5/U EExd Zone & ( liter or < enclosures) ICG 5/U ( liter or > enclosures) Zone & downstream@nexans.com

25 SINGLE CONDUCTOR TYPE MMV MEDIUM VOLTAGE 5KV, 00/% INSULATION LEVEL Ampacity Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm 7-05 (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 8 /0 /0 /0 / MV -0MV -0MV -0MV -05MV -0MV -07MV -08MV -09MV -05MV -0MV -MV -05MV -MV -MV -0MV -MV -MV -075MV -MV SINGLE CONDUCTOR TYPE MMV MEDIUM VOLTAGE 8KV, 00% INSULATION LEVEL Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm 7-05 (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) /0 /0 /0 / MV -9MV -0MV -MV -MV -MV -MV -MV -78MV -MV -7MV -79MV -8MV -9MV -8MV -MV -MV -87MV -MV Ampacity See page 5 for ampacity notes. Manufactured by Nexans AmerCable Fax:

26 7-05 TYPE MMV MEDIUM VOLTAGE CABLE (MV-05) Single Conductor: 5kV kv, 00% & % Levels. Rated 05 C Ampacity: Based on 05 C conductor temperature and 0 C ambient temperature SINGLE CONDUCTOR TYPE MMV MEDIUM VOLTAGE 8KV, % INSULATION LEVEL Ampacity Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm 7-05 (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) /0 /0 /0 / MV -5MV -MV -7MV 5-8MV 70-9MV 8-0MV 09 -MV -MV -MV 9 -MV 78-89MV 89 -MV 7 -MV -90MV 7 -MV -7MV 79-9MV 9-8MV SINGLE CONDUCTOR TYPE MMV MEDIUM VOLTAGE KV, 00% INSULATION LEVEL Ampacity See page 5 for ampacity notes. Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm 7-05 (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) /0 /0 /0 / MV -MV -MV -MV -MV -5MV -98MV -MV -7MV -99MV -8MV -9MV -9MV -0MV -MV -9MV -MV downstream@nexans.com

27 SINGLE CONDUCTOR TYPE MMV MEDIUM VOLTAGE KV, % INSULATION LEVEL Ampacity Inductive Voltage Single DC AC Size Part Nominal Weight Reactance Drop In Free Triangular Banked Resistance Resistance AWG/ No. Diameter (Lbs./ (ohms/ (Volts/amp/ Air Configuration in Tray at 5 C at 90 C, 0 Hz kcmil mm 7-05 (inches) 000 ft.) 000 ft.) 000 ft.) (amps) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) /0 /0 /0 / MV -MV -MV -7MV -8MV -9MV -9MV -70MV -7MV -95MV -7MV -7MV -9MV -7MV -75MV -97MV -7MV Notes: ) Ampacities in air are based on NEC 0 Table 0.0(C)(9), Volts Ampacity column, for insulated single copper conductor isolated in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities in Triangular Configuration are based on NEC 0 Table 0.0(C)(7), Volts Ampacity column, for insulated copper conductor cables isolated triplexed in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities in cable tray are based on NEC 0 Section 9.80(B)() and Table 0.0(C)(9), Ampacity column, maximum conductor temperature of 05 C, ambient air temperature of 0 C. Manufactured by Nexans AmerCable Fax:

28 7-05 TYPE MMV MEDIUM POWER CABLE (MV-05) Three Conductor: 5kV kv, 00% & % Levels. Rated 05 C Conductors Soft annealed flexible stranded tinned copper per IEEE 80 Table. Extruded thermosetting 05 C Ethylene Propylene Rubber (EPR), meeting UL 07. Metallic Shield Composite shield consisting of 0.0" tinned copper braided with nylon providing 0% copper Shielded coverage meeting UL 07. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need to remove the shield to find an underlying colored tape. Ratings & Approvals UL Listed as Medium Voltage Cable (E) Flame retardance: IEEE 0 & IEC 0 Sunlight Resistant Cable Tray Use (Sizes /0 AWG and larger) 05 C Temperature Rating Voltage Rating 5kV to kv (5kV available on request) Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 07. Shield Semi-conducting tape, with overlap, for fast and easy termination meeting UL 07. Grounding Conductor (optional) One uninsulated soft annealed flexible stranded tinned copper conductor per ASTM B and sized according to Table. of UL 07. A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 07. Colored jackets for signifying different voltage levels are also available on special request (ie. yellow = 5kV, orange = 8kV and red = kv). Armor (optional) (Optional) 0.0" bronze braid providing 88% minimum coverage. *Cable with grounding conductor can be directly buried. Cable without grounding conductor can be directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section.(A)(5). Sheath (optional) A black, arctic grade, flame retardant, oil, abrasion, chemical, and sunlight resistant thermosetting compound meeting UL 07. Colored jackets for signifying different voltage levels is also available on special request (ie. yellow = 5kV, orange = 8kV and red = kv). APPLICATIONS Nexans AmerCable medium voltage power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations. Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, or messengersupported in industrial establishments and electric utilities. Suitable for direct burial.* FEATURES n These cables utilize flexible stranded conductors, braided shields and a braided armor (when armored) which make them very suitable for applications involving repeated flexing and high vibration. n These cables have a small minimum bending radius (xod for unarmored cables and 8xOD for armored cables) for easy installation. n Optional uninsulated grounding conductors sized per UL 07. n The increased flexibility of this cable allows for faster installation times. Hawke Gland Types Unarmored Armored & Sheathed Industrial & Safe Area (IP8) -X Increased Safety EExe / /5/U Explosion Proof Class I, Div. Class I, Div. Class I, Zone Class I, Zone & Flameproof / /5/U EExd Zone & ( liter or < enclosures) ICG 5/U ( liter or > enclosures) Zone & downstream@nexans.com

29 THREE CONDUCTOR TYPE MMV MEDIUM VOLTAGE 5KV, 00/% INSULATION LEVEL THREE CONDUCTOR TYPE MMV MEDIUM VOLTAGE 8KV, 00% INSULATION LEVEL Single Inductive Size Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm 7-05 (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor /0 5 /0 70 /0 8 / MV -MV -MV -MV -5MV -MV -7MV -8MV -9MV -7MV -0MV -MV -75MV -MV -MV -MV -MV -MV -77MV -MV Ampacity Single Inductive Size Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm 7-05 (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor /0 /0 /0 / To order with Grounding Conductor, add G to Part Number.5-7MV -8MV -9MV -0MV 5 -MV 70 -MV 8 -MV 09 -MV -78MV -5MV 9 -MV 78-79MV 89-7MV 7-8MV -80MV 7-9MV -MV 79-8MV 9 -MV Ampacity /0 /0 /0 /0 8 /0 /0 /0 /0 See page 9 for ampacity notes Manufactured by Nexans AmerCable Fax:

30 7-05 TYPE MMV MEDIUM VOLTAGE CABLE (MV-05) Three Conductor: 5kV kv, 00% & % Levels. Rated 05 C Ampacity: Based on 05 C conductor temperature and 0 C ambient temperature THREE CONDUCTOR TYPE MMV MEDIUM VOLTAGE 8KV, % INSULATION LEVEL THREE CONDUCTOR TYPE MMV MEDIUM VOLTAGE KV, 00% INSULATION LEVEL Single Inductive Size Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm 7-05 (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor /0 /0 /0 / MV -MV -MV -5MV -MV -7MV -8MV -9MV -8MV -0MV -MV -8MV -MV -MV -8MV -MV -5MV Ampacity Single Inductive Size Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm 7-05 (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor /0 /0 /0 / To order with Grounding Conductor, add G to Part Number MV -7MV -8MV -9MV -MV -5MV -8MV -5MV -5MV -87MV -5MV -55MV -88MV -5MV Ampacity /0 /0 See page 7 for ampacity notes /0 Ordering Type MMV Medium Voltage Cables Example: Nexans AmerCable conductor power cable Type MMV Prefix kv 00% # AWG Grounding Conductor 7 05 MV G Specific Cable Number (from charts) Ground Conductor G with ground Blank no ground downstream@nexans.com

31 THREE CONDUCTOR TYPE MMV MEDIUM VOLTAGE KV, % INSULATION LEVEL Single Inductive Size Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Voltage Drop Optional AWG/ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (ohms/ (Volts per amp Grounding kcmil mm 7-05 (inches) 000 ft.) (amps) (amps) (ohms/000 ft.) (ohms/000 ft.) 000 ft.) per 000 ft.) Conductor /0 /0 /0 / MV -58MV 5-59MV 70-0MV 8 -MV 09 -MV -9MV -MV 9 -MV 78-9MV 89-5MV 7 -MV -9MV 7-7MV To order with Grounding Conductor, add G to Part Number Ampacity Notes: ) Ampacities in air are based on NEC 0 Table 0.0(C)(7), Volts Ampacity column, for insulated three conductor copper cable isolated in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities in cable tray are based on NEC 0 Table 0.0(C)(75), Volts Ampacity column, for insulated three conductor copper cable in isolated conduit in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. * Three conductor cables with ground wires are also suitable for VFD applications /0 Closest Equivalent Uninsulated Size Number IEEE 5 Metric Size Conductor AWG/kcmil of Strands Std. Size (mm) Dia. (inches) 8 /0 /0 /0 / MMV Stranding Profile Manufactured by Nexans AmerCable Fax:

32 7-05VFD TYPE MMV-VFD POWER CABLE (MV-05) Three Conductor: 8kV kv % Level Rated 90 C Conductors () Soft annealed flexible stranded tinned copper per IEEE 80 Table. Extruded thermosetting 05 C Ethylene Propylene Rubber (EPR), meeting UL 07. Shield Composite shield consisting of 0.0" tinned copper braided with nylon providing 0% copper Shielded coverage meeting UL 07. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need to remove the shield to find an underlying colored tape. Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 07. Ratings & Approvals n UL Listed as Medium Voltage Cable (E) n Flame retardance: IEEE 0 & IEC 0 n Sunlight Resistant n Cable Tray Use (Sizes /0 AWG and larger) n 05 C Temperature Rating n Voltage Rating 5kV to kv (5kV available on request) Shield Semi-conducting layer meeting UL 07. Symmetrical Insulated Grounding Conductors () Soft annealed flexible stranded tinned copper conductor per IEEE 80 Table. Gexol sized per Table. of UL 07. Color: Green EMI Shield Overall tinned copper braid plus aluminum/ polyester tape provides 00% coverage. A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 07. This jacket allows for isolation between the insulation shields and overall shield. Shields can then be terminated on opposite ends to minimize circulating currents. Sheath (optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 07. Colored jackets for signifying different voltage levels are also available on special request (orange = 8kV and red = kv). APPLICATIONS A flexible, braid and foil shielded, power cable specifically engineered for use in medium voltage variable frequency AC drive (VFD) applications. FEATURES n Flexible stranded conductors and braided shields. Suitable for applications involving repeated flexing and high vibration. n Small minimum bending radius (8x OD) for easy installation. n has a very low dielectric constant. This allows for longer output cable distances and minimizes common mode current. n Overall braid plus foil shield is engineered with 00% coverage and a surface transfer impedance < milliohms at 0MHz to contain EMI. n Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. n High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. n Severe cold durability: exceeds CSA cold bend/cold impact (-0 C/-5 C). downstream@nexans.com

33 THREE CONDUCTOR TYPE MMV-VFD MEDIUM VOLTAGE 8KV % INSULATION LEVEL Ampacity Single Inductive Voltage Green Insulated Size Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding AWG/ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (Ohms/ (Volts/Amp/ Conductor (x) kcmil mm 7-05 (Inches) 000 Ft.) (Amps) (Amps) (Ohms/000 Ft.) (Ohms/000 Ft.) 000 Ft.) 000 Ft.) Size (AWG) /0 /0 /0 / VFDMV -VFDMV -VFDMV -5VFDMV -VFDMV -7VFDMV -8VFDMV -9VFDMV -8VFDMV -0VFDMV -VFDMV -8VFDMV -VFDMV -VFDMV -8VFDMV -TVFDM THREE CONDUCTOR TYPE MMV-VFD MEDIUM VOLTAGE KV % INSULATION LEVEL Ampacity Single Inductive Voltage Green Insulated Size Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding AWG/ Part No. Diameter (Lbs./ Air in Trays at 5 C at 90 C, 0Hz (Ohms/ (Volts/Amp/ Conductor (x) kcmil mm 7-05 (Inches) 000 Ft.) (Amps) (Amps) (Ohms/000 Ft.) (Ohms/000 Ft.) 000 Ft.) 000 Ft.) Size (AWG) /0 /0 /0 / VFDMV -58VFDMV -59VFDMV -0VFDMV -VFDMV -VFDMV -9VFDMV -VFDMV -VFDMV -9VFDMV -5VFDMV -VFDMV -9VFDMV Stranding Profile: See Page 9 Ordering Type MMV-VFD Medium Voltage Cables Example: conductor MMV-VFD power cable kv # AWG Nexans AmerCable Type MMV-VFD Prefix VFDMV Specific Cable Number (from charts) Manufactured by Nexans AmerCable Fax:

34 CORFLEX MC-HL INSTRUMENTATION 00V PAIRS & TRIADS 00V/000V MARINE SHIPBOARD CABLE Rated 90 C Single or Multiple Individually Shielded Pairs or Triads, Overall Cable Shield Flame-retardant PVC, mils nominal thickness, nylon jacket, mil nominal thickness. 90 C temperature rating, per UL Standard. Shield Aluminum foil/polyester shield helically wrapped to provide 00% coverage and tinned copper drain wire that is two gauge sizes smaller than the circuit conductors. These shields are electrically isolated from each other. Armor Continuous corrugated and welded, impervious aluminum sheath with no more than 0.% trace copper providing complete protection against liquid and gas ingress. Provides excellent mechanical protection, additional electrostatic shielding, and serves as an easy means for grounding equipment. Assembly Pairs/triads are cabled in concentric layers with interstices filled with suitable non-hygroscopic fillers, as required. A binder tape of synthetic material assembles the core in an essentially round configuration. Ratings & Approvals Conductor Bare, annealed copper conforming to ASTM B and Class B stranded in accordance with ASTM B8. Overall Cable Shield Aluminum foil/polyester shield helically wrapped to provide 00% coverage. Tinned copper drain wire that is the same size as the circuit conductors. Inner Polyvinyl chloride jacket, over cabled core as per UL9, 90 C temperature rating, with additional resistance to flame spread. A rip cord is laid longitudinally under the jacket to facilitate stripping. Overall black polyvinyl chloride jacket per UL 9, 90 C temperature rating; low acid gas emission; limited flame spread and excellent corrosion resistance. Conductor ID Pairs: black/white & number coded Triads: black/red/white & number coded 90 C Temperature Rating Meets UL 9 and IEEE 80 requirements for Marine Shipboard Cable Meets UL 9 requirements for Type MC, Metal Clad cables Meets UL 5 for Hazardous Locations Designated Type MC as per NEC 008 and NEC 0 Article APPLICATION CORFLEX instrumentation cables minimize noise and signal interference to enhance performance in instrumentation, data flow, computer & data logging applications especially in areas where high voltages or high currents are present. FEATURES UL listed as Marine Shipboard Cable (File E89) 00V/000V UL listed as Type MC-HL, 00V (File E709) UL listed insulated conductors Flame retardant: UL 85 and IEEE 8 vertical tray fire tests at 70,000 BTU/hr, ICEA T-9-50 fire test at 0,000 BTU/hr, IEC 0- category A fire test, IEEE 0 and CSA FT Cables are American Bureau of Shipping (ABS) listed as CWC MC Type MC Cables are marked -0 C and are suitable for handling and installation down to -0 C (based on - 0 C impactand bend tests per UL 9) Temperature rating of 90 C dry and wet C emergency rating and C short circuit rating Continuous, impervious aluminum armor corrugated for flexibility, prevents ingress of moisture, gases and liquids Aluminum armor resistance exceeds requirements of the NEC 008 and NEC 0 Article.78 for equipment grounding conductor Minimal noise and signal interference Excellent mechanical and physical properties Sunlight resistant jacket Suitable for direct burial, use in cable tray and embedment in concrete Suitable for Class I, II and III, Divisions & as per NEC 008 and NEC 0 (HL Rated) BEND RADIUS Fixed position: 7 x cable overall diameter During pulling: x cable overall diameter CORFLEX is a registered trademark of Nexans downstream@nexans.com

35 PAIRS WITH INDIVIDUAL AND OVERALL SHIELD 00V 8 AWG (7W) 00V/000V MARINE SHIPBOARD CABLE Nexans Design No No. of Pairs 8 Thickness PVC (mils) Nylon (mils) Nominal Diameter Over Core (inches) Inner Thickness (mils) 0 0 Nominal Diameter Over Inner (inches) Nominal Diameter Over Armor (inches) Outer Thickness (mils) Nominal Diameter Over Outer (inches) Approx. Net Cable Weight (lb/kft) PAIRS WITH INDIVIDUAL AND OVERALL SHIELD 00V AWG (7W) 00V/000V MARINE SHIPBOARD CABLE Nexans Design No No. of Pairs 8 Thickness PVC (mils) Nylon (mils) Nominal Diameter Over Core (inches) Inner Thickness (mils) 0 0 Nominal Diameter Over Inner (inches) Nominal Diameter Over Armor (inches) Outer Thickness (mils) 0 Nominal Diameter Over Outer (inches) Approx. Net Cable Weight (lb/kft) TRIADS WITH INDIVIDUAL AND OVERALL SHIELD 00V AWG (7W) 00V/000V MARINE SHIPBOARD CABLE Nexans No. Design of No. Triads Thickness PVC (mils) Nylon (mils) Nominal Diameter Over Core (inches) Inner Thickness (mils) 0 Nominal Diameter Over Inner (inches) Nominal Diameter Over Armor (inches) Outer Thickness (mils) Nominal Diameter Over Outer (inches) Approx. Net Cable Weight (lb/kft) ELECTRICAL PROPERTIES PAIRS/TRIADS WITH INDIVIDUAL AND OVERALL CABLE SHIELD Capacitance Pairs Triads Conductor Size (AWG) DC Resistance 0 C) Conductor Conductor (pf/ft) Conductor Shield (pf/ft) Conductor Conductor (pf/ft) Conductor Shield (pf/ft) Manufactured by Nexans AmerCable Fax:

36 CORFLEX MC-HL ARMORED POWER & CONTROL 00V MULTI-CONDUCTOR 00V/000V MARINE SHIPBOARD CABLE Rated 90 C Multi-Power Conductors with Bare Ground(s) Conductor Bare, annealed copper conforming to ASTM B and Class B stranded in accordance with ASTM B8. Assembly Conductors are cabled in concentric layers with grounding wire, interstices are filled with suitable non-hygroscopic fillers, as required. A binder tape of synthetic material assembles the core in an essentially round configuration. Overall black polyvinyl chloride jacket per UL 9, 90 C temperature rating; low acid gas emission; limited flame spread and excellent corrosion resistance. Conductor ID Multi-conductor AWG to 0 AWG: Method #-E per ICEA S-7-5 Ratings & Approvals Cross-linked polyethylene type XHHW- per UL. Grounding Conductor Bare, annealed copper conforming to ASTM B and Class B stranded in accordance with ASTM B8. Meets or exceeds requirements of NEC Table.. Armor Continuous corrugated and welded, impervious aluminum sheath with no more than 0.% trace copper providing complete protection against liquid and gas ingress. Provides excellent mechanical protection, additional electrostatic shielding, and serves as an easy means for grounding equipment. 90 C Temperature Rating Meets UL 9 and IEEE 80 requirements for Marine Shipboard Cable Meets UL, XHHW- 00V conductors Meets UL 9 requirements for Type MC, Metal Clad cables Meets UL 5 for Hazardous Locations (HL) Dual certified IEEE 80 and UL 9 Type CWCMC Designated Type MC as per NEC 008 and NEC 0 Article Meets CSA C. No. for Aluminum Sheathed Cables Meets CSA C. No. 7 for Hazardous Locations APPLICATION Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world requiring a type MC-HL cable. FEATURES UL listed as Marine Shipboard Cable (File E89) 00V/000V UL listed as Type MC-HL, 00V (File E709) UL listed insulated conductors Flame retardant: UL 85 and IEEE 8 vertical tray fire tests at 70,000 BTU/hr, ICEA T-9-50 fire test at 0,000 BTU/hr, IEC 0- category A fire test, IEEE 0 and CSA FT Cables are American Bureau of Shipping (ABS) listed as CWC MC Type MC Cables are marked -0 C and are suitable for handling and installation down to -0 C (based on - 0 C impact and bend tests per UL 9) Temperature rating of 90 C dry and wet C emergency rating and C short circuit rating Continuous, impervious aluminum armor corrugated for flexibility, prevents ingress of moisture, gases and liquids Aluminum armor resistance exceeds requirements of the NEC 008 and NEC 0 Article.78 for equipment grounding conductor Armor provides good EMI shielding so that CORFLEX can be used in certain instrumentation applications when adequately grounded Excellent mechanical and physical properties Sunlight resistant jacket Suitable for direct burial, use in cable tray and embedment in concrete Suitable for Class I, II and III, Divisions & as per NEC 008 and NEC 0 (HL Rated) BEND RADIUS Fixed position: 7 x cable overall diameter During pulling: x cable overall diameter CORFLEX is a registered trademark of Nexans downstream@nexans.com

37 POWER & CONTROL 00V 00V/000V MARINE SHIPBOARD CABLE Nexans Design No No. of Cond. * Conductor Size AWG/ kcmil (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) Thickness (mils) Ground Wire Size AWG (7w) x8(7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) Nominal Diameter Over Core (inches) Nominal Diameter Over Armor (inches) Thickness (mils) Nominal Diameter Over (inches) Approx. Net Cable Weight (lb/kft) DC Resistance 0 C Ω/kft DC Resistance 5 C Ω/kft AC Resistance 90 C 0 Hz Ω/kft Inductive Reactance 90 C Ω/kft@0Hz Voltage Drop Volts/ Amps/kft Ampacities (Note ) 75 C C * (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) x(7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) (7w) * (7w) 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) x(7) 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) Notes: ) Ampacities are in accordance with NEC 008 Table 0. or NEC 0 Table 0.(B)() for conductors in raceway or direct buried at C ambient temperature and 90 C conductor temperature. The overcurrent protection shall not exceed amperes for AWG, 0 amperes for AWG, and amperes for 0 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied (NEC 008 and NEC 0 Article 0.(D)). For correction factors for different ambient temperatures and ampacities at different conductor temperatures, see NEC 008 Table 0. or NEC 0 Table 0.(B)(). Ampacities for cables having more than three conductors have been derated per NEC 008 Article 0.(B)()(a) or NEC 0 Article 0.(B)()(a). *Three conductor cables with grounds are also suitable for VFD applications. Manufactured by Nexans AmerCable Fax:

38 CORFLEX MC-HL ARMORED COMPOSITE POWER & CONTROL 00V MULTI-CONDUCTOR 00V/000V MARINE SHIPBOARD CABLE Rated 90 C Bare Ground Grounding Conductor Bare, annealed copper conforming to ASTM B and Class B stranded in accordance with ASTM B8. Meets or exceeds requirements of NEC Table.. Assembly Conductors are cabled in concentric layers with grounding wire, interstices are filled with suitable non-hygroscopic fillers, as required. A binder tape of synthetic material assembles the core in an essentially round configuration. Conductor ID Power Conductors 8 AWG and larger: Method # per ICEA S-7-5 Control Conductors, & 0 AWG: Method #-E per ICEA S-7-5 Ratings & Approvals Conductor Bare, annealed copper conforming to ASTM B and Class B stranded in accordance with ASTM B8. Cross-linked polyethylene type XHHW- per UL. Armor Continuous corrugated and welded, impervious aluminum sheath with no more than 0.% trace copper providing complete protection against liquid and gas ingress. Provides excellent mechanical protection, additional electrostatic shielding, and serves as an easy means for grounding equipment. Overall black polyvinyl chloride jacket per UL 9, 90 C temperature rating; low acid gas emission; limited flame spread and excellent corrosion resistance. 90 C Temperature Rating Meets UL 9 and IEEE 80 requirements for Marine Shipboard Cable Meets UL, XHHW- 00V conductors Meets UL 9 requirements for Type MC, Metal Clad cables Meets UL 5 for Hazardous Locations (HL) Dual certified IEEE 80 and UL 9 Type CWCMC Designated Type MC as per NEC 008 and NEC 0 Article Meets CSA C. No. for Aluminum Sheathed Cables Meets CSA C. No. 7 for Hazardous Locations APPLICATION Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world requiring a type MC-HL cable. FEATURES UL listed as Marine Shipboard Cable (File E89) 00/000V UL listed as Type MC-HL, 00V (File E709) UL listed insulated conductors Flame retardant: UL 85 and IEEE 8 vertical tray fire tests at 70,000 BTU/hr, ICEA T-9-50 fire test at 0,000 BTU/hr, IEC 0- category A fire test, IEEE 0 and CSA FT Cables are American Bureau of Shipping (ABS) listed as CWC MC Type MC Cables are marked -0 C and are suitable for handling and installation down to -0 C (based on - 0 C impact and bend tests per UL 9) Temperature rating of 90 C dry and wet C emergency rating and C short circuit rating Continuous, impervious aluminum armor corrugated for flexibility, prevents ingress of moisture, gases and liquids Aluminum armor resistance exceeds requirements of the NEC 008 and NEC 0 Article.78 for equipment grounding conductor Armor provides good EMI shielding so that CORFLEX can be used in certain instrumentation applications when adequately grounded Excellent mechanical and physical properties Sunlight resistant jacket Suitable for direct burial, use in cable tray and embedment in concrete Suitable for Class I, II and III, Divisions & as per NEC 008 and NEC 0 (HL Rated) BEND RADIUS Fixed position: 7 x cable overall diameter During pulling: x cable overall diameter CORFLEX is a registered trademark of Nexans downstream@nexans.com

39 COMPOSITE POWER & CONTROL 00V 00V/000V MARINE SHIPBOARD CABLE Nexans Design No. Power Conductors No. x Size AWG/ kcmil 9970 x0(7w) x0(7w) x0(7w) x0(7w) 9 x0(7w) 7 x0(7w) Control Conductors No. x Size AWG/ kcmil x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) Ground Wire Size AWG 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) Power Thickness (mils) Control Thickness (mils) Nominal Diameter Over Core (in) Nominal Diameter Over Armor (in) Thickness (mils) Nominal Diameter Over (in) Approx. Net Cable Weight (lbs/kft) DC Resist. 0C /kft DC Resist. 5C /kft AC Resist. 90C, 0 Hz /kft Inductive Reactance 90C, 0 Hz /kft Voltage Drop Volts/ Amps/kft Ampacities (Note ) 75 C 90 C x8(7w) x8(7w) x8(7w) x8(7w) x8(7w) x8(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) 0(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) 8(7w) 8(7w) 8(7w) 8(7w) 8(7w) 8(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) 8(7w) 8(7w) 8(7w) 8(7w) 8(7w) 8(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) x(7w) (7w) (7w) (7w) (7w) (7w) (7w) Notes: ) Ampacities are based on NEC 0 Table 0.(B)() for not more than three current-carrying conductors (where the th conductor is the neutral of a -phase, wire system) in raceway, cable, or earth (direct buried), based on an ambient temperature of C (8 F). Refer to Table 0.(B)() for the ampacity correction factors where the ambient temperature is other than C (8 F). Manufactured by Nexans AmerCable Fax:

40 CORFLEX MC-HL Power Cable 00V 00V/000V Marine Shipboard Cable Rated 90 C and Power Conductors with Ground(s) Cross-linked polyethylene type XHHW- per UL. Grounding Conductor(s) Bare, annealed copper conforming to ASTM B and Class B stranded in accordance with ASTM B8. Meets or exceeds requirements of Armor Continuous corrugated and welded, impervious aluminum sheath with no more than 0.% trace copper providing complete protection against liquid and gas ingress. Provides excellent mechanical protection, additional electrostatic shielding, and serves as an easy means for grounding equipment. Ratings & Approvals Conductors Bare, annealed copper conforming to ASTM B and Class B stranded in accordance with ASTM B8. Assembly Conductors are cabled in concentric layers with grounding wire, interstices are filled with suitable non-hygroscopic fillers, as required. A binder tape of synthetic material assembles the core in an essentially round configuration. Overall black polyvinyl chloride jacket per UL 9, 90 C temperature rating; low acid gas emission; limited flame spread and excellent corrosion resistance. Conductor ID Sizes AWG to AWG: Method #-E per ICEA S-7-5 Sizes AWG to 0 kcmil: Method # per ICEA S C Temperature Rating Meets UL 9 and IEEE 80 requirements for Marine Shipboard Cable Meets UL, XHHW- 00V conductors Meets UL 9 requirements for Type MC, Metal Clad cables Meets UL 5 for Hazardous Locations (HL) Dual certified IEEE 80 and UL 9 Type CWCMC Designated Types MC and MC-HL as per NEC 0 Articles, and 5 Meets CSA C. No. for Aluminum Sheathed Cables Meets CSA C. No. 7 for Hazardous Locations Application Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world requiring a type MC-HL cable. Features UL listed as Marine Shipboard Cable (File E89) 00V/000V UL listed as Type MC-HL, 00V (File E709) UL listed insulated conductors Flame retardant: UL 85 and IEEE 8 vertical tray fire tests at 70,000 BTU/hr, ICEA T-9-50 fire test at 0,000 BTU/hr, IEC 0- category A fire test, IEEE 0 and CSA FT Cables are marked -0 C and are suitable for handling and installation down to -0 C (based on - 0 C impact and bend tests per UL 9) Temperature rating of 90 C dry and wet C emergency rating and C short circuit rating Continuous, impervious aluminum armor corrugated for flexibility, prevents ingress of moisture, gases and liquids Aluminum armor resistance exceeds requirements of the NEC 0 Article.78 for equipment grounding conductor Excellent mechanical and physical properties Sunlight resistant jacket Suitable for direct burial, use in cable tray and embedment in concrete Three conductor cables have three symmetrical grounding conductors suitable for PWM/VFD and other modern AC drive/motor applications Suitable for Class I, II and III, Divisions & as per NEC 008 and NEC 0 (HL Rated) Bend Radius Fixed position: 7X cable overall diameter During pulling: X cable overall diameter CORFLEX is a registered trademark of Nexans downstream@nexans.com

41 POWER CABLE 00V 00V/000V MARINE SHIPBOARD CABLE Cond. Nexans Size Design AWG/ No. kcmil 70 (7w) 777 (7w) 70 (7w) 79 (7w) 70 0(7w) 779 0(7w) 708 8(7w) 775 8(7w) 709 (7w) 77 (7w) 70 (7w) 777 (7w) 70 (7w) 779 (7w) 70 (9w) 9857 (9w) 70 /0(9w) 788 /0(9w) 708 /0(9w) 78 /0(9w) 709 /0(9w) 0 /0(9w) 700 /0(9w) 787 /0(9w) 70 (7w) (7w) 70 (7w) 789 (7w) 70 0(7w) 797 0(7w) No. of Cond. Thickness (mils) Ground Wire Size AWG x8(7w) x(7w) x(7w) x(7w) x(7w) x0(7w) x(7w) x0(7w) x(7w) x8(7w) x(7w) x8(7w) x0(7w) x(7w) x0(7w) x(7w) x0(7w) x(7w) x0(7w) x(7w) x8(7w) x(7w) x8(7w) x(7w) x8(7w) x(7w) x(7w) x(7w) x(7w) x(7w) Nominal Nominal Diameter Diameter Over Over Core Armor (in) (in) Thickness (mils) Nominal Diameter Over (in) Approx. Net Cable Weight (lbs/kft) DC Resist. 0C /kft DC Resist. 5C /kft AC Resist. 90C, 0 Hz /kft Inductive Reactance 90C, 0 Hz /kft Voltage Drop Volts/ Amps/kft Ampacities (Note ) Notes: ) Ampacities are based on NEC 0 Table 0.(B)() for not more than three current-carrying conductors (where the th conductor is the neutral of a -phase, wire system) in raceway, cable, or earth (direct buried), based on an ambient temperature of C (8 F). Refer to Table 0.(B)() for the ampacity correction factors where the ambient temperature is other than C (8 F). ) Three conductor cables with ground wires are also suitable for VFD applications. 75 C C Manufactured by Nexans AmerCable Fax:

42 CORFLEX MV-05 OR MC-HL MEDIUM VOLTAGE 5KV % INSULATION LEVEL 8KV 00% INSULATION LEVEL Rated 05 C Conductors with Bare Grounds Conductor Bare, annealed copper conforming to ASTM B and Class B Compact stranded in accordance with ASTM B9. Grounding Conductors Bare, annealed copper conforming to ASTM B and Class B stranded in accordance with ASTM B8. Shield Nonmetallic Extruded semiconducting insulation shield meets or exceeds electrical and physical requirements of UL 07. Armor Continuous corrugated and welded, impervious aluminum sheath with no more than 0.% trace copper providing complete protection against liquid and gas ingress. Provides excellent mechanical protection, additional electrostatic shielding, and serves as an easy means for grounding equipment. Ratings & Approvals Conductor Shield Extruded semiconducting conductor shield meets or exceeds electrical and physical requirements of UL 07. EPR meets or exceeds electrical and physical requirements of UL 07. Metallic Shield Bare copper tape shield helically wrapped to provide 00% coverage. Binder Tape Synthetic material assembles the core in an essentially round configuration. Overall yellow polyvinyl chloride jacket per UL 07, 90 C temperature rating; low acid gas emission; limited flame spread and excellent corrosion resistance. 05 C Temperature Rating Meets UL 9 and IEEE 80 requirements for Marine Shipboard Cable Meets UL 07 requirements for medium voltage power cables Meets UL 9 requirements for Type MC, Metal Clad cables Meets UL 5 for Hazardous Locations (MC-HL) Designated Type MC as per NEC 008 and NEC 0 Article meets electrical and physical requirements of ICEA S-9-9/NEMA WC 7 and UL 07 Designated Type MV-05 as per NEC 008 and NEC 0 Article 8 APPLICATION Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world requiring a type MV-05 or MC-HL Medium Voltage cable. FEATURES UL listed as Marine Shipboard Cable (File E89) UL listed as Type MV-05 5kV and 8kV (File E90) Flame retardant: UL 85 and IEEE 8 vertical tray fire tests at 70,000 BTU/hr, IEC 0- category A fire test, IEEE 0 and CSA FT Cables are American Bureau of Shipping (ABS) listed as CWC MC Type MV/MC (Metal Clad, Medium Voltage) Cables are marked -0 C and are suitable for handling and installation down to -0 C (based on - 0 C impactand bend tests per UL 9) Continuous, impervious aluminum armor corrugated for flexibility, prevents ingress of moisture, gases and liquids Aluminum armor resistance exceeds requirements of the NEC 008 and NEC 0 Article.78 for equipment grounding conductor Excellent mechanical and physical properties Minimal noise and signal interference Sunlight resistant jacket Suitable for direct burial, use in cable tray and embedment in concrete Suitable for Class I, II and III, Divisions & as per NEC 008 and NEC 0 (HL Rated) Three symmetrical grounding conductors for PWM/VFD and other modern AC drive/motor applications Phase identification: Color coded (black, red, blue) polyester ribbon laid longitudinally under the copper shield tape BEND RADIUS Fixed position: 7 x cable overall diameter During pulling: x cable overall diameter CORFLEX is a registered trademark of Nexans downstream@nexans.com

43 5KV % INSULATION LEVEL EPR INSULATION: 90 MILS Cond. Nexans Size Part AWG/ No. kcmil 087 (7w) 088 (7w) 089 (7w) 080 (8w) 08 /0(8w) 08 /0(8w) 08 /0(8w) 08 (w) 085 (w) 08 0(w) 087 7(58w) (58w) Cond. Nexans Size Part AWG/ No. kcmil 77 (7w) 7 (7w) 007 (7w) 08 (8w) 8 /0(8w) 707 /0(8w) 709 /0(8w) 9 (w) 0075 (w) 007 0(w) 09 7(58w) 000(58w) Ground Wire Size AWG x 0 x 0 x 0 x 8 x 8 x 8 x x x x x x 8KV 00% INSULATION LEVEL EPR INSULATION: MILS Ground Wire Size AWG x 0 x 0 x 0 x 8 x 8 x 8 x x x x x x Nominal Nominal Diameter Nominal Over (in) Notes: ) Ampacities in air are based on NEC 0 Table 0.0(C)(7), Volts Ampacity column, for insulated three conductor copper cable isolated in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities in cable tray are based on NEC 0 Table 0.0(C)(75), Volts Ampacity column, for insulated three conductor copper cable in isolated conduit in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities for direct burial are based on NEC 0 Table 0.0(C)(8), Volts Ampacity column, for insulated three conductor copper cable, directly buried, maximum conductor temperature of 05 C, ambient earth temperature of 0 C, 00 percent load factor, earth thermal resistivity of 90 C cm / W. * Three conductor cables with ground wires are also suitable for VFD applications. Nominal Nominal Diameter Nominal Over (in) Diameter Over Core (in) Diameter Over Core (in) Diameter Over Armor (in) Diameter Over Armor (in) Thickness (mils) Thickness (mils) Nominal Diameter Over (in) Nominal Diameter Over (in) Approx. Net Cable Weight (lbs/kft) Approx. Net Cable Weight (lbs/kft) In Air Note Ampacities Cable Tray Note Direct Burial Note DC Resist. 0C /kft DC Resist. 5C /kft AC Resist. 90C, 0 Hz /kft Inductive Reactance 90C, 0 Hz /kft Voltage Drop Volts/ Amps/kft Notes: ) Ampacities in air are based on NEC 0 Table 0.0(C)(7), 0-5,000 Volts Ampacity column, for insulated three conductor copper cable isolated in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities in cable tray are based on NEC 0 Table 0.0(C)(75), 0-5,000 Volts Ampacity column, for insulated three conductor copper cable in isolated conduit in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities for direct burial are based on NEC 0 Table 0.0(C)(8), 0-5,000 Volts Ampacity column, for insulated three conductor copper cable, directly buried, maximum conductor temperature of 05 C, ambient earth temperature of 0 C, 00 percent load factor, earth thermal resistivity of 90 C cm / W. * Three conductor cables with ground wires are also suitable for VFD applications. In Air Note Ampacities Cable Tray Note Direct Burial Note DC Resist. 0C /kft DC Resist. 5C /kft AC Resist. 90C, 0 Hz /kft Inductive Reactance 90C, 0 Hz /kft Voltage Drop Volts/ Amps/kft Manufactured by Nexans AmerCable Fax:

44 CORFLEX MV-05 OR MC-HL MEDIUM VOLTAGE KV 00% INSULATION LEVEL & % INSULATION LEVEL Rated 05 C Conductors with Bare Ground Conductor Bare, annealed copper conforming to ASTM B and Class B Compact stranded in accordance with ASTM B9. Grounding Conductor Bare, annealed copper conforming to ASTM B and Class B stranded in accordance with ASTM B8. Shield Nonmetallic Extruded semiconducting insulation shield meets or exceeds electrical and physical requirements of UL 07. Armor Continuous corrugated and welded, impervious aluminum sheath with no more than 0.% trace copper providing complete protection against liquid and gas ingress. Provides excellent mechanical protection, additional electrostatic shielding, and serves as an easy means for grounding equipment. Ratings & Approvals Conductor Shield Extruded semiconducting conductor shield meets or exceeds electrical and physical requirements of UL 07. EPR meets or exceeds electrical and physical requirements of UL 07. Metallic Shield Bare copper tape shield helically wrapped to provide 00% coverage. Binder Tape Synthetic material assembles the core in an essentially round configuration. Overall red polyvinyl chloride jacket per UL 07, 90 C temperature rating; low acid gas emission; limited flame spread and excellent corrosion resistance. 05 C Temperature Rating Meets UL 9 and IEEE 80 requirements for Marine Shipboard Cable Meets UL 07 requirements for medium voltage power cables Meets UL 9 requirements for Type MC, Metal Clad cables Meets UL 5 for Hazardous Locations (MC-HL) Designated Type MC as per NEC 008 and NEC 0 Article meets electrical and physical requirements of ICEA S-9-9/NEMA WC 7 and UL 07 Designated Type MV-05 as per NEC 008 and NEC 0 Article 8 APPLICATION CORFLEX is a registered trademark of Nexans Designed and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world requiring a type MV-05 or MC-HL Medium Voltage cable. FEATURES UL listed as Marine Shipboard Cable (File E89) UL listed as Type MV-05 kv (File E90) Flame retardant: UL 85 and IEEE 8 vertical tray fire tests at 70,000 BTU/hr, IEC 0- category A fire test, IEEE 0 and CSA FT Cables are American Bureau of Shipping (ABS) listed as CWC MC Type MV/MC (Metal Clad, Medium Voltage) Cables are marked -0 C and are suitable for handling and installation down to -0 C (based on - 0 C impact and bend tests per UL 9) Continuous, impervious aluminum armor corrugated for flexibility, prevents ingress of moisture, gases and liquids Aluminum armor resistance exceeds requirements of the NEC 008 and NEC 0 Article.78 for equipment grounding conductor Excellent mechanical and physical properties Minimal noise and signal interference Sunlight resistant jacket Suitable for direct burial, use in cable tray and embedment in concrete Suitable for Class I, II and III, Divisions & as per NEC 008 and NEC 0 (HL Rated) Phase identification: Color coded (black, red, blue) polyester ribbon laid longitudinally under the copper shield tape BEND RADIUS Fixed position: 7 x cable overall diameter During pulling: x cable overall diameter downstream@nexans.com

45 KV 00% INSULATION LEVEL Nexans Design No Cond. Size AWG/ kcmil (7w) (8w) /0(8w) /0(8w) /0(8w) (w) (w) 0(w) 7(58w) Ground Wire Size AWG /0 Nominal Nominal Diameter Nominal Over (in) Diameter Over Core (in) Diameter Over Armor (in) Thickness (mils) Nominal Diameter Over (in) Approx. Net Cable Weight (lbs/kft) In Air Note Ampacities Cable Tray Note Direct Burial Note DC Resist. 0C /kft DC Resist. 5C /kft AC Resist. 90C, 0 Hz /kft Inductive Reactance 90C, 0 Hz /kft Voltage Drop Volts/ Amps/kft Notes: ) Ampacities in air are based on NEC 0 Table 0.0(C)(7), 0-5,000 Volts Ampacity column, for insulated three conductor copper cable isolated in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities in cable tray are based on NEC 0 Table 0.0(C)(75), 0-5,000 Volts Ampacity column, for insulated three conductor copper cable in isolated conduit in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities for direct burial applications are based on NEC 0 Table 0.0(C)(8), 0-5,000 Volts Ampacity column, for insulated three conductor copper cable, directly buried, maximum conductor temperature of 05 C, ambient earth temperature of 0 C, 00 percent load factor, earth thermal resistivity of 90 C cm / W. KV % INSULATION LEVEL Nexans Design No Cond. Size AWG/ kcmil (7w) (8w) /0(8w) /0(8w) /0(8w) (w) (w) 0(w) Ground Wire Size AWG Nominal Nominal Diameter Nominal Over (in) Diameter Over Core (in) Diameter Over Armor (in) Thickness (mils) Nominal Diameter Over (in) Approx. Net Cable Weight (lbs/kft) In Air Note Ampacities Cable Tray Note Direct Burial Note DC Resist. 0C /kft DC Resist. 5C /kft AC Resist. 90C, 0 Hz /kft Inductive Reactance 90C, 0 Hz /kft Voltage Drop Volts/ Amps/kft Notes: ) Ampacities in air are based on NEC 0 Table 0.0(C)(7), 0-5,000 Volts Ampacity column, for insulated three conductor copper cable isolated in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities in cable tray are based on NEC 0 Table 0.0(C)(75), 0-5,000 Volts Ampacity column, for insulated three conductor copper cable in isolated conduit in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) Ampacities for direct burial applications are based on NEC 0 Table 0.0(C)(8), 0-5,000 Volts Ampacity column, for insulated three conductor copper cable, directly buried, maximum conductor temperature of 05 C, ambient earth temperature of 0 C, 00 percent load factor, earth thermal resistivity of 90 C cm / W. Manufactured by Nexans AmerCable Fax:

46 CORFLEX PULLING INSTRUCTIONS Certain installations require the pulling of CORFLEX into ducts or trays. These installations require careful planning and execution. The following provides information on how to calculate tensions developed during pulling and what precautions to take to prevent damage to the cable. Pulling Tension The maximum tension applied to a cable is limited to prevent damage or distortion of cable components which could reduce the life or reliability of the cable. The method of pulling is significant in that different methods will result in different stresses on critical cable components for the same overall tension. Nexans AmerCable recommends that CORFLEX MC-HL Instrumentation 00V cables are pulled by means of the aluminum sheath and jacket with a grip applied over the jacketed core, sheath and overall jacket. All other CORFLEX cable types described in this catalog should be pulled by means of the conductors, aided with a grip over the outer aluminum sheath. The conductors and the sheath must be pulled together. Maximum allowable pulling tensions for CORFLEX cables should never exceed the values shown in pulling tension table. Calculating Pulling Tensions The tension developed in any Straight Section of duct is calculated as: T = L x W x f lbf where L = section length (feet) W = cable weight per unit length (lb/foot) f = coefficient of dynamic friction The tension developed in any Bend is calculated as: T = T x e fa lbf where T = tension at bend entrance (lbf) e = base of natural logarithms (.788) f = coefficient of dynamic friction a = angle of bend (radians) or e fa is given in the following table for common conditions: Bend Angle f=0. f=0. f=0.5 f= Coefficients of dynamic friction with lubricant are given in the following table for common duct and cable jacket materials. These coefficients can be used for calculation of tensions. Coefficient Duct Type Cable of Friction PVC PVC 0. PE PVC 0. Fiber PVC 0.0 Asbestos Cement PVC 0.70 Considerations must be given to Side Wall Bearing Pressure (SWBP) when pulling CORFLEX through a bend. The SWBP is calculated as follows: SWBP = Pulling Tension Cable at Bend Exit (lbf) Radius of Bend (feet) For CORFLEX, Nexans AmerCable recommends a maximum SWBP of 0 pounds force/foot. During installation of the CORFLEX cable, it is recommended that the bend radii be as noted in the cable descriptions. Pulling in Duct It is extremely important for the success of any pull in duct to use approved lubricants. Lubricants must be compatible with the cable jacket and duct material. Lubricating the pulling rope will decrease the tension on the pulling equipment and more importantly will reduce the risk of damage to the inside of the duct which in turn can damage the cable. When designing the duct layout, it is suggested that the bends be concentrated near the end from which the cable is to be pulled. This practice will result in lower tensions. In some cases, the tensions resulting from alternative directions should be calculated. Pulling in Trays & Trenches For the installation of CORFLEX in trays, rollers are normally used. Using well lubricated rollers and long radius sheaves at bends will result in a lower coefficient of friction when compared to duct. A coefficient of friction of 0. can be used when calculating pulling tension using rollers. For long pulls with bends it may be necessary to install assist pullers before the bends to reduce the tension on the cable entering a bend and reducing the risk of damage from excessive SWBP. The recommendations given above are intended to cover a wide variety of pulling conditions. It is possible, under ideal conditions, and with experienced supervision, to exceed these limits. For further guidance, see IEEE Paper 8 T & D 5-, or contact Nexans AmerCable. downstream@nexans.com

47 CORFLEX CONDUCTOR ID Method #-E per ICEA S-7-5 Conductor Stripe Conductor Stripe st BLACK 9th ORANGE Blue nd RED 0th YELLOW Blue rd BLUE st BROWN Blue th ORANGE nd BLACK Orange 5th YELLOW rd RED Orange th BROWN th BLUE Orange 7th RED Black 5th YELLOW Orange 8th BLUE Black th BROWN Orange 9th ORANGE Black 7th BLACK Yellow 0th YELLOW Black 8th RED Yellow th BROWN Black 9th BLUE Yellow th BLACK Red th ORANGE Yellow th BLUE Red st BROWN Yellow th ORANGE Red nd BLACK Brown th YELLOW Red rd RED Brown th BROWN Red th BLUE Brown 7th BLACK Blue 5th ORANGE Brown 8th RED Blue th YELLOW Brown Method of ICEA S-7-5 Conductor Printing Details Conductor Printing Details st -ONE- 5th 5-FIVE-5 nd -TWO- th -SIX- rd -THREE- 7th 7-SEVEN-7 th -FOUR- 8th 8-EIGHT-8 CORFLEX is a registered trademark of Nexans Manufactured by Nexans AmerCable Fax:

48 7-XXX TYPE RHH OR RHW- 000 VOLTS POWER & CONTROL 90 C Limited Smoke (Sizes /0 and higher) EP/CPE Conductor Bare, annealed copper conforming to ASTM B and Class B stranded, in accordance with ASTM B8 Flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE) See below for jacket color options (Special order) Ratings & Approvals Separator Suitable separator tape provides easy stripping of insulation Ethylene-Propylene rubber (EPR) n ICEA S-95-58/NEMA WC-70: Nonshielded Power Cables Rated 000 Volts or Less for the Distribution of Electrical Energy n UL Standard : Thermoset Insulated Wires & Cables, Types RHH, RHW-. UL VW- n UL Standard 85: Vertical Tray Fire propagation and Smoke Release Test for Electrical and optical Fiber Cables. (UL,ST-) n MSHA P-8 n RoHS Compliant APPLICATION Type RHH or RHW- 000 Volt Power and Control Cables are recommended for general power and control applications. These cables may be used in generating plants, substations and industrial plants. Type RHH or RHW- may be used up to 90 C in dry or wet locations. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts, cable tray (size /0 AWG and larger per NEC 9) or lashed to a messenger for aerial installation. FEATURES n A two layer composite of flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE) outer layer and Ethylene- Propylene rubber (EPR) inner layer. The composite design provides significant diameter reductions compared to designs using full thickness jackets. n Suitable for continuous operating temperatures of 90 C, wet or dry n Rated RHH, RHW-; /0 AWG and larger listed and marked for CT use n UL listed as Sunlight Resistant n and jacket meet hazardous waste regulations, per Code of Federal Regulations 0 Section (0CFR) for characteristic lead content n Flame Resistance: FT-/IEEE0 for sizes /0 AWG and larger; UL VW- n Meets smoke release and other requirements of Vertical Cable Tray Test UL 85 and is marked ST- for /0 kcmil downstream@nexans.com

49 7-XXX TYPE RHH OR RHW- 000 VOLTS POWER AND CONTROL Part No. 7-XXX- Size AWG/ kcmil Minimum Wires per Conductor Nominal Thickness in. Nominal Thickness in. Nominal Outside Diameter in. Approx. Weight lbs. per,000 ft. *Ampacity 90 C TBD TBD TBD TBD TBD TBD TBD TBD TBD / TBD / TBD / TBD / TBD TBD TBD TBD * Ampacity Calculated with at 90 C conductor temperature and C ambient air, per 0 NEC Table 0.(B)(7) Cable diameters are subject to +/-5% manufacturing tolerance SAVE TIME Order Your RHH or RHW- Cable with Factory Installed Connectors SAVE MONEY Manufactured by Nexans AmerCable Fax:

50 Nexans AmerCable is the leading global manufacturer of jacketed power, control and instrumentation cables for harsh industrial environments. Nexans AmerCable is an ISO 900 certified cable manufacturer that combines leadingedge technology, proven manufacturing techniques and high quality service to deliver the finest cable products available. Our professional field engineering and customer support teams work directly with customers or in partnership with a network of independent distributors to deliver productivity enhancing cable solutions for downstream facilities. WHAT CAN YOU EXPECT FROM NEXANS AMERCABLE? High-Quality Cable with an Emphasis on Safety On-Time Delivery Professional Sales, Support and Service Strategic Inventory Locations Short Lead Times NEXANS AMERCABLE S DOWNSTREAM CABLE PRODUCTS Industrial VFD Foil shielded, power cables engineered for use in variable frequency AC drive applications. Available in several constructions Industrial CIR Crush and Impact Resistant cables without external armoring CORFLEX Type MC-HL Cables Nexans Tray Cables Cables for wet or dry locations in cable trays, raceways, open air or direct burial Nexans Instrumentation Cables 0V & 00V Pairs and Triads 0 West Little York Building # Suite # Houston, TX Fax: downstream@nexans.com 0, AmerCable Incorporated _

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology

More information

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant

More information

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic

More information

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C

More information

DLO Flexible Power Cable

DLO Flexible Power Cable Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C

More information

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation

More information

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum

More information

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line

More information

TIGER BRAND MINING CABLES

TIGER BRAND MINING CABLES TIGER BRAND MINING CABLES 5-kV TYPE SHD-GC & MP-GC -55 TYPE SHD-GC /C MOLD-CURED CPE JACKET 0 VOLTS 00% INSULATION LEVEL s Flexible tinned copper Flexible tinned copper with yellow polypropylene insulation

More information

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Low Voltage AIRGUARD. A proven, rugged product for harsh environments Low Voltage AIRGUARD A proven, rugged product for harsh environments Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable

More information

Instrumentation Cables

Instrumentation Cables around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS OCTOBER 2014 CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive

More information

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables CATALOG OF PRODUCTS Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material.

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary TRAY-RATED CABLE Quick Select Chart 48 TC 600/TC 600 S 50 Flexible Tray Cable with TC-ER for Easier Installations; Unshielded & Shielded TRAY II/TRAY II CY 52 Extremely Oil-Resistant & Flexible Tray Cable

More information

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from LAPP products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph:(10)358-3130 (800)638-1830 fx:(10)358-312 (800)872-9329 RFQ form: http://mdmetric.com/rfq.htm Flexible Tray

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

METAL CLAD WIRING SYSTEM

METAL CLAD WIRING SYSTEM METAL CLAD WIRING SYSTEM The Preferred Cable for CLASS I, DIVISION 1 OR ZONE 1 Best Cable for PWM Circuits THE OKONITE COMPANY Ramsey, New Jersey 07446 METAL CLAD WIRING SYSTEM The Preferred Cable for

More information

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength thermosetting EPR-based insulation, Type XHHW-2, cabled with bare copper grounding conductors and fillers,

More information

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery Bulletin OSC OKONITE CABES STOCK CATAOG In Stock for Immediate Delivery THE OKONITE COMPANY 0 Hilltop Road, Ramsey, New Jersey 07 Phone.8.000 www.okonite.com INDEX Data Sheet Section:Sheet GOSSARY OF TERMS

More information

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The

More information

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*) Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX

More information

SIMpull THHN, it slips and slides - all with NoLube.

SIMpull THHN, it slips and slides - all with NoLube. SOUTHWIRE S SIMpull THHN Southwire maintains its goal of revolutionizing the wire industry by providing its consumers with a product that is not only SIMpull but also requires NoLube. SIMpull THHN is a

More information

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors

More information

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*) Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX

More information

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488 ÖLFLEX TRAY II/TRAY II CY Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded ÖLFLEX TRAY II ÖLFLEX TRAY II CY Unshielded Construction : Finely stranded bare copper Jacket:

More information

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a. 734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was

More information

Mongoose PT Platform Shale Shaker

Mongoose PT Platform Shale Shaker Mongoose PT Platform Shale Shaker (UL VERSION) Revision: A By: MT Mongoose Platform Page 1 of 10 NOTE: Mongoose PT Platform Shale Shaker The attached is a reference to M-I SWACO s STANDARD Mongoose Platform

More information

VSD cables in. Working with. industrial & automation applications

VSD cables in. Working with. industrial & automation applications Cable Efficiency in Automation Connectivity Cabinet Control Working with VSD cables in industrial & automation applications Description of a VSD System A functional VSD system consists of at least three

More information

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires

More information

SUPERIOR MARINE CABLE SOLUTIONS

SUPERIOR MARINE CABLE SOLUTIONS SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables

More information

THHN12STGN500 THHN 12 STR Green 500

THHN12STGN500 THHN 12 STR Green 500 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

THHN2BK2500 THHN 2 STR Black 2500

THHN2BK2500 THHN 2 STR Black 2500 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Conductor

More information

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09) KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications

More information

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN500BK500 THHN 500 STR Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics

More information

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category THHN6WH500 THHN 6 STR White 500 Southwire Company

More information

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LBK500 THHN 12 Sol Black 500 Southwire Company Catalog Number Manufacturer Description Weight per unit Product

More information

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500 Southwire Company Catalog Number Manufacturer Description Weight per

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

Conductors and Raceway Design

Conductors and Raceway Design IEEE Southern Alberta Section, Industrial Applications and Power & Energy Chapter Technical Program Conductors and Raceway Design Blair Sackney, Southwire Canada George Morlidge SMIEEE, Fluor Canada May

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Coax (2-1505A Type) 20 AWG BC, GIFPE isulation, Duofoil plus TC braid (95% cv.), PVC inner jackets. Pairs (4-9451 Type): 22 AWG TC, PP insul.,

More information

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6 Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6 Lutze Inc 10 South Ridge Dr Charlotte, NC 282 Phone 0-0-0222 Fax 0-0-022 Toll free 1-800--21 www.lutze.com info@lutze.com Lutze Flexible Control

More information

SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection

SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX Products for Variable Frequency Drive Applications ake the right connection ake the right connection Connectivity solutions that keep you moving. Variable Frequency

More information

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables 5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables Description Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system

More information

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships Tray Cable Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for over 35 years, Texcan

More information

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry ADC is a proud Sustaining Member of the IMSA organization and is the largest manufacturer in

More information

Underground System Design TADP 547

Underground System Design TADP 547 Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 24 AWG stranded (7x32) TC conductor, Datalene insulation, pairs individually shielded with bonded Beldfoil with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil

More information

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Cable Solutions for Servo and Variable Frequency Drives (VFD) Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect

More information

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39 Product Index SECTION PAGES Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products 0 Power and Control Tray Cable Products 9 Armored Products 0 5 5 Merchandising 5 Technical Information

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded

More information

Communication, Control, and Industrial Cable

Communication, Control, and Industrial Cable Communication, Control, and Industrial Cable Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 291 Get control of demanding applications T he broad

More information

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010 (0,25mm) XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance

More information

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation

More information

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT A. General In a hazardous location grounding of an electrical power system and bonding of enclosures of circuits and electrical equipment in the

More information

Multi-Paired Cable Product Finder

Multi-Paired Cable Product Finder Multi-Paired Cable Product Finder Technical Information NO. STRAND TYPE C00 U......................, 0 0 C000 F........................ C0 FB....................... C FB....................... C0 F.......................

More information

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and

More information

Armoured Power and Control Cables to BS7917

Armoured Power and Control Cables to BS7917 1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit

More information

A. Product Description: Stranded conductor insulated wire.

A. Product Description: Stranded conductor insulated wire. SECTION 16120CPPR CONDUCTORS AND CABLE PART 1 - GENERAL 1.1 SYSTEM DESCRIPTION A. Product Requirements: Provide products as follows: 1. All building wire shall be stranded copper (no aluminum wire). 2.

More information

For tough, seaworthy wire

For tough, seaworthy wire Dearborn Marine The Premier Choice for Marine Applications For tough, seaworthy wire and cable, Alpha Wire s Dearborn brand of products delivers performance in the most challenging environments for electrical

More information

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables 5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables Applications Three copper conductors cable, each with a semiconducting conductor shield, high dielectric strength VOLTALENE TRXLPE

More information

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable 05 63 Technical information 64 Primary Wire 66 Brake Cable & Portable Extension Cable 67 SXL & Bonded Wire WIRE & CABLE FILS ET CÂBLES 68 Trailer Cable 70 Battery Cable 71 Welding Cable 72 Booster Cable

More information

Armoured Power and Control Cables Fire Resistant

Armoured Power and Control Cables Fire Resistant Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity

More information

SECTION BUILDING WIRE AND CABLE

SECTION BUILDING WIRE AND CABLE SECTION 260519 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Building wire and cable. 2. Wiring connectors and connections. B. RELATED SECTIONS 1. Section 26 05 53 Electrical Identification. 2. Section

More information

Power Cables and their Application

Power Cables and their Application Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,

More information

Electronically published by ABS Piraeus. Reference T , dated 30-AUG-2018.

Electronically published by ABS Piraeus. Reference T , dated 30-AUG-2018. UNTEL KABLOLARI SAYI VE TICARET ANONIM SIRKETI MAKINE OSB, 6.CAD. NO: 4 41455 DILOVASI-GEBZE KOCAELI Turkey Telephone: + 90 262 722 93 30 Fax: + 90 262 722 94 92 Email: info@untel.com.tr Web: www.untel.com.tr

More information

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications HS Series Made of thermally stabilized cross-linked polyolefin, enabling a recovered wall thickness greater than that of the cable jacket replaced Withstands severe mechanical requirements of U.R.D., submersible,

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

Speaker Audio System Cables

Speaker Audio System Cables Product Guide Speaker Audio System Cables www.westpennwire.com 1 Load Speaker Cable Distance Speaker (Loadspeaker) Levels: Power (%)/Loss (db) 4Ω Systems 8Ω Systems 70V System AWG 11% 21% 50% 11% 21% 50%

More information

LGH High Voltage Connectors

LGH High Voltage Connectors Introduction Product Facts No exposed high voltage parts Space saving maximum performance from small size and weight Fast connect and disconnect Wide temperature range -67 F to +257 F [-55 C to +5 C],

More information

Shielded Fire Alarm Cables

Shielded Fire Alarm Cables PLENUM Low-Smoke PVC JACKET UL TYPE FPLP/CMP/CL3P C(UL) CMP 300 VOLT Shielded Fire Alarm Cables Fire Alarm, Signal Monitor/Detection Audio or Control Circuits Description: Chart F, Page 41 Shielded Plenum

More information

protim-r Module

protim-r Module 200200 protim-r Module Description The 200200 dual-input protim-r (DIN Rail mount) provides two channels of measurement. All acceleration-to-velocity (A-V) channels condition the signal from an accelerometer

More information

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

Field Instrument Cable. Electrical Noise

Field Instrument Cable. Electrical Noise Field Instrument Cable Electrical Noise 1 Electrical Noise Instrument Cables are Susceptible to 4 Types of Noise: Static Magnetic Cross-Talk Common Mode 2 Static Noise Static Noise is caused by an electric

More information

Continuous Flex Data Cable

Continuous Flex Data Cable 1,! gti',',n Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 080--Main Office: () 88-00-Outside Local Area: (800) 8-00-www.stevenengineering.com Continuous Flex Data Cable UNITRONIC

More information

Industrial Automation & Control Cables

Industrial Automation & Control Cables 6 Industrial Automation & Control Cables Table Contents Introduction 2 Innovcable Data Solutions - Industrial Ethernet 3 Coaxial Cables 3 Innovcable Data Solutions - Industrial Twinax 4 Enerhose Cables

More information

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations 5-35kV MV-105 Power (Tape Shield) 20120124 Description Design Parameters Options Single conductor cable with stranded copper or aluminum conductor, triple extruded insulation system consisting of a thermosetting

More information

Heat-Shrinkable Tubing

Heat-Shrinkable Tubing HS Series 3:1 Shrink Ratio Made of thermally stabilized cross-linked polyolefin, enabling a recovered wall thickness greater than that of the cable jacket replaced Withstands severe mechanical requirements

More information

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables 5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables Description Three conductor cable with stranded copper or aluminum conductors, triple extruded insulation system consisting of

More information

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4 Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked

More information

protim-r Module

protim-r Module 200200 protim-r Module Bently Nevada* Asset Condition Monitoring Description The 200200 dual-input protim-r (DIN rail mount) provides 2 channels of measurement. All acceleration-to-velocity (A-V) channels

More information

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations SBCA Industry Standards Subcommittee Document: SBCA Series 6 Recommended Practices Date of Issue: Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

More information

Airport Cables & Connectors

Airport Cables & Connectors Airport Cables & Connectors Aircraft Cable & Connector Products Descrip on 0 Hz Single Jacket No Contact Sec on 0 Hz Single Jacket With Replaceable Durable Hard Nose Contact Sec on 0 Hz Single Jacket -

More information

Short-Circuit Current Calculations

Short-Circuit Current Calculations Basic Point-to-Point Calculation Procedure Step. Determine the transformer full load amps (F.L.A.) from either the nameplate, the following formulas or Table : Multiplier = 00 *% Z transformer Step 2.

More information

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature ÖLFLEX HEAT Cable Solutions for Extreme Temperature ÖLFLEX Reliable performance no matter how extreme the temperature. Choosing the best cable for applications involving extreme temperatures is one of

More information

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use HS Series 3:1 Shrink Ratio Made of thermally stabilized cross-linked polyolefin, enabling a recovered wall thickness greater than that of the cable jacket replaced Withstands severe mechanical requirements

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

Nexans Industrial Solutions PRODUCT CATALOG

Nexans Industrial Solutions PRODUCT CATALOG Nexans Industrial Solutions PRODUCT CATALOG i NEXANS BRINGS ENERGY TO LIFE COPPER CABLES Nexans brings energy to life through an extensive range of cables and cabling solutions that deliver increased performance

More information

American Electrical Institute

American Electrical Institute American Electrical Institute Oregon Electricians Continuing Education Grounding & Bonding (Article 250) 4 Hours American Electrical Institute PO Box 31131 Spokane, WA 99223 www.aeitraining.com Article

More information

FieldLink MC at 20 x outer diameter Torsion

FieldLink MC at 20 x outer diameter Torsion Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation

More information

Article 250 Grounding & Bonding

Article 250 Grounding & Bonding Article 250 Grounding & Bonding AMERICAN ELECTRICAL INSTITUTE N16 W23217 Stone Ridge Dr. Waukesha, WI 53188 855-780-5046 www.aeitraining.com DISCLAIMER NOTE: This course is APPROVED for continuing education

More information

MarineLine YOZp 0,6/1 kv

MarineLine YOZp 0,6/1 kv Properties Application: Light, armoured, reduced low voltage power cables for power and lighting applications in all ship areas. Characteristics: Class 2 s Light, reduced Halogen free and low smoke, flame

More information

Armoured Power and Control Cables to BS6883

Armoured Power and Control Cables to BS6883 Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in

More information

High Temperature Flexible Control Cable

High Temperature Flexible Control Cable High Temperature Flexible Control Cable 0 High Temperature Flexible Control Cable SILFLEX UL/CSA UL/CSA/CE 0 High Temperature Silicone Control Cable with UL/CSA SILFLEX SiHF CE 0 High Temperature Silicone

More information