Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

Size: px
Start display at page:

Download "Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS"

Transcription

1 Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION SOLUTIONS COAXIAL CABLES BUILDING MANAGEMENT SYSTEMS BROADCASTING & STUDIO

2 Prysmian Group Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as a primary driver in the development of communities. With this in mind, we provide major global organisations in many industries with bestinclass cable solutions, based on stateoftheart technology. Through two renowned commercial brands Prysmian and Draka based in almost countries, we re constantly close to our customers, enabling them to further develop the world s energy and telecoms infrastructures, and achieve sustainable, profitable growth. What links communications to communities? Cable solutions to support the development of the world s telecoms infrastructure. As the world s largest producer of telecoms cables, supporting the infrastructures of many of the world s leading telecoms operators, the Prysmian Group delivers optical fibre and copper cabling solutions that help link communications to communities around the globe. Covering voice, video and data transmission, we are world leader in the production of optical fibre, offering unique and fully owned technology. Our portfolio sets the benchmark in global innovation, and is the outcome of continuous multimillion Euro investment in R&D and production in more than facilities worldwide.

3 Index PRYSMIAN GROUP LINKING THE FUTURE 1. INDUSTRIAL COMMUNICATION 4 3. BUILDING MANAGEMENT 68 SOLUTIONS SYSTEMS 1.1 CanBus 120 Ohm & EIB Bus Ohm 1.2 Foundation Fieldbus 1.3 Profibus 1.4 Industrial Ethernet 1.5 JAMAK Industrial Data 1.6 NOMAK Industrial Data 1.7 LONAK Industrial Data 1.8 Outside Plant Industrial FO EIA Screened Control Cable 3.3 Max FOH 3.4 Firetuf 3.5 Fibre Optic Cables 3.6 MultiPair Category Cables 4. BROADCASTING & STUDIO Cables 2. COAXIAL CABLES 58

4 1. 1. An interesting cabling concept for industrial automation has established itself under the keyword ICS ( ). It concerns the structured cabling of industrial plants similar to the cabling used for office communications. Ethernet in industry is increasingly asserting itself because the communication standard used in countless office applications can be classified today as being simple, costeffective and highly flexible, as well as having broad support on the system side. Industrial Ethernet and bussystems are proven standards in the industry. More and more plants are completely equipped with these systems and connected with special cabling, functioning in every environment. Access to specific areas throughout the network makes adjustments and changes easily manageable. The Draka brand of Multimedia Specials cables are supplied to almost all of the world s major Industrial projects developments. These cables provide utmost protection and transmission capabilities in very harsh environments. Requirements of the cabling area Draka s cable solution Control Level Ethernet TCP/IP Copper cable Fibre Optic cable Control Level Standard Ethernet (UC Cables) Standard Optical fibre (UC FIBRE ) Automation Level HSEIndustrial Ethernet cable Profibus FMS/DP cable Automation Level Industrial Ethernet Optical fibre cables Profibus DP CANBUS Field Level 420mA/Hart Instrumentation cable Foundation Fieldbus cable Profibus PA cable Ex i Field Level Profibus PA Foundation Fieldbus AIC cables (420mA) 4

5 CanBus 120 Ohm & EIB Bus Ohm Li2YC11Y 2 x 2 x 0.22m 2 FRNC Li09YS(St)C11Y 2 x 0.35m 2 LSZH EIB Bus Ohm 1.2 Foundation Fieldbus FF FC 1x2xAWG16/7 PVC FF FC 1x2xAWG18/1 PVC 02YSY(St)CY 1x2x1.3/2.55 Li PVC FF FC 1x2xAWG18/7 LSHFFR FF FC 1x2xAWG18/1 GST PVC FF FC 1x2xAWG18/7 SWB PVC FF FC 1x2xAWG18/7 SWB LSZH 1.3 Profibus PB PA FC 1x2xAWG18/1 PVC PB PA FC 1x2xAWG16/7 PVC PB PA FC 1x2xAWG16/7 LSHFFR PB PA FC 1x2xAWG18/19 PVC PB PA FC 1x2xAWG18/7 LSHFFR PB PA 1x2xAWG18/7 LSHFFR PB PA FC 1x2xAWG18/1 GST PVC PB PA FC 1x2xAWG18/7 SWB PVC PB DP BASIC 1x2xAWG22/1 LSHF PB DP FC 1x2xAWG22/1 LSHFFR PB DP FC 1x2xAWG22/1 LSHFFR + PE PB DP FC 1x2xAWG22/1 PE PB DP FC 1x2xAWG24/19 PUR PB DP FC 1x2xAWG24/19 TRAILING PUR PB DP FC 1x2xAWG22/1 SWB LSHF 1.4 Industrial Ethernet UC0 Cat.5e F/UTP SWB LSZHFR UC400 Cat.6 F/UTP SWB LSZHFR IE ToughCat 5e LSHFFR IE ToughCat 5e LSHFFR MUD IE ToughCat 7 LSHFFR IE ToughCat 7 LSHFFR MUD IE ToughCat 7S* Armoured IE SuperCat 7 HS23 Cat.7 LSHF IE UC0 SS23 Cat.7 (L)H LSHFFR IE UC0 SS23 Cat.7 PE IE UC0 SS23 Cat.7 PUR IE UC0 SS27 Cat.7 PUR 1.5 JAMAK Industrial Data JAMAK JAMAK C LSZH JAMAK HF JAMAK ARM 1.6 NOMAK Industrial Data NOMAK NOMAK E 1.7 LONAK Industrial Data LONAK 2 x 1.3 mm² LONAK 2x2x0.65 LONAK 2x2x0.8 LONAK 2 x 1.3 mm² ARM 1.8 Outside Plant Industrial FO Cables UMNWV_ALPA SMLVLVWV_LEAD LMNWG_ALPA TF20_ALP LTFMSMNWM_NYLON

6 Canbus 120 Ohm & EIB Bus Ohm to DIN and EN to ISO Standards acc. to customer Specification Li2YC11Y 2 x 2 x 0.22 mm² FRNC CanBusCable Construction Colour code Core identification Cable lay up Wrapping Overall screen Foil Sheath Sheath colour Tensile force N Bending radius moving application fixed application stranded bare copper wire, diameter 7 x 0.20 mm mm (cross section 0.22 mm²) PE, ± 0.05 mm Wall thickness 0.46 mm Pair 1: 1 x white, 1 x brown Pair 2: 1 x yellow, 1 x green 4 cores twisted to a star quad mm 1 x PETfoil, overlapping mm Tinned copper braid mm Optical coverage 85% 1 x PETfoil under sheath mm PUR Low Smoke Zero Halogen ± 0.2 mm Black, RAL 05 Nom. 6.9 mm Nom. 70 kg/km x outer diameter of cable 5 x outer diameter of cable Operating temperature 40 C up to + 85 C UV resistance Testing of oil resistance of PU sheath material acc. to VDE 0282 Part 10 and EN and thermal endurance graph (Arrhenius) and life expectancy of PU sheath material acc. to ISO 2578 Requirements after aging: max. change of tensile strength: 50% max. change of elongation at break: 50% Mobil DTE 13 M (Hydraulic oil) Tribol 1710/20 (Gear oil) acc. to IEC days at C approx. 24 years at 65 C 25 years at 20 C 140 days at C approx. 18 years at 65 C 25 years at 20 C Ozone resistance acc. to EN , clause 8 Smoke density acc. to EN , IEC and 2 Corrosivity EN and 2, IEC and 2 resistance (at 20 ± 5 C) Ω/km Characteristic impedance at 1 MHz 120 Ω ± 15% Capacitance at 800 Hz (nominal) 41 nf/km resistance (at 20 ± 5 C and 500 V) 10 GΩxkm Test voltage (AC, 1 min) Core/core and core/screen 1.2 kv 18 CS28600 CanBus, Li2YC11Y 2 x 2 x 0.22 mm² FRNC 6

7 Li09YS(St)C11Y 2 x 0.35 mm² LSZH CanBusCable Construction Twisting Core identification Overall screen Foil Sheath Sheath colour Tensile force N Mechanical Properties Bending radius during installation without load with load stranded bare copper wire, diameter 7 x 0.26 mm mm (cross section 0.35 mm²) FoamSkin PP, ± 0.1 mm wall thickness 0.71 mm 2 cores + 2 x PPfillers twisted to the pair mm 1x white, 1x green 1 x PETAlfoil mm tinned stranded drain wires 19 x 0,15 mm + tinned copper braid mm optical coverage 65% 1 x PETfoil under sheath mm PUR Low Smoke Zero Halogen ± 0.2 mm wall thickness 0.75 mm Black, RAL 05 Nom. 6.8 mm Nom kg/km x cable diameter 10 x cable diameter Operating temperature C up to + 70 C Storage temperature 40 C up to 85 C UV resistance of sheath material acc. to IEC Ozone resistance acc. to EN , clause 8 Smoke density (light transmittance 25%) acc. to EN , IEC and 2 Corrosivity acc. EN and 2, IEC and 2 Testing of oil resistance of PU sheath material acc. to VDE 0282 Part 10 and EN and thermal endurance graph (Arrhenius) and life expectancy of PU sheath material acc. to ISO 2578 Requirements after aging: max. change of tensile strength: 50% max. change of elongation at break: 50% Mobil DTE 13 M (Hydraulic oil) Tribol 1710/20 (Gear oil) 150 days at C approx. 24 years at 65 C 25 years at 20 C 140 days at C approx. 18 years at 65 C 25 years at 20 C 1.1 Canbus 120 Ohm & EIB Bus Ohm to DIN and EN to ISO Standards acc. to customer Specification 1. resistance (at 20 ± 5 C) 54.5 Ω/km Characteristic impedance at 1 MHz 120 Ω ± 15% resistance (at 20 ± 5 C and 500 V) 10 GΩxkm Operating voltage (50 Hz, rms) 60 V Test voltage (AC, 1 min) Core/core and core/screen 1.2 kv Transfer impedance (up to 10 MHz, acc. to IEC ) 10 mω/m 11 CS250 CanBusCable, Li09YS(St)C11Y 2 x 0.35 mm² LSZH 7

8 Canbus 120 Ohm & EIB Bus Ohm EIB BUS, PVC EIB Bus cables Symmetrical data cable for EIB BUS Systems Construction identification Pair stranding Cable lay up Wrapping Overall shielding Rip cord and identification thread Outer sheath Copper wire, bare 0.5 mm2, 0.80 mm Ø PE, 1.6 mm Ø Pair 1: red, black, Pair 2: Yellow, white 2 conductors to the pair 1 or 2 pairs to the core 1 x PET foil Laminated ALfoil + copper drain wire 0.4mm2 yes PVC, alternative LSFROH, white RAL 10 / green RAL 6018 Nom mm Nom kg/km Bus cable for indoor installations in EIB (European Installation Bus) systems. The cable is suitable for installation in ducts, on risers and under data floors. PE insulated plain copper conductors. The cable has an overall Al/PETPfoil screen and a tinned copper drain wire. The overall sheath is made of flame retardant PVC. The pair is colour coded for easy identification. 1 pair: black/red 2 pair: yellow/white Mechanical Properties Operating temperature 25 C up to + 70 C Min. Installation temperature 5 C Minimum bending radius 7.5 x D Smoke density (only for LSFROH types) acc. to IEC Corrosivity of fire gases (only for LSZH types) acc. to IEC /2 Loop DC resistance (max.) 73.2 Ω/km resistance (at 500 V, 1 min.) 10 GΩ*km Mutual capacitance at 800 Hz (max.) nf/km Inductance 0.65 mh/km Max. operating voltage DC 800 V AC Testvoltage, (5 min) 2500 V AC Testvoltage, (1 min) 4000 V Ordering Information 3582 EIB BUS Cable PVC, 1x2x EIB BUS Cable PVC, 2x2x EIB BUS Cable LSFROH, 1x2x EIB BUS Cable LSFROH, 2x2x EIB BUS Cable LSFROH GN, 2x2x0.8 8

9 FF FC 1x2xAWG16/7 PVC FOUNDATION Fieldbus FC AWG16 FLEX PVC Cable 1.2 Foundation Fieldbus 1. Stranding Bedding Static screen Braid Sheath Colour Tensile force N stranded bare copper wires, 7x mm, (crosssection AWG16/7) PE, mm two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% PVC, mm yellow Nom. 9.5 mm Nom. 129 kg/km 270 Bending radius Single bending 50 mm Repeated bending mm Temperature range 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 28.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Standards Electrical Data at 20 C Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± FOUNDATION Fieldbus FC AWG16 FLEX PVC Cable, FF FC 1x2xAWG16/7 PVC 9

10 Foundation Fieldbus FF FC 1x2xAWG18/1 PVC FOUNDATION Fieldbus FC INST PVC Cable Stranding Bedding Static screen Braid Sheath Sheath Colour Tensile force N bare copper wire, mm, (crosssection AWG18) foamskinpe, mm two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% PVC, mm yellow Nom. 8.0 mm Nom. 78 kg/km 175 Bending radius Single bending 40 mm Repeated bending 80 mm Temperature range 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Standards Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 46 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Electrical Data at 20 C Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± FOUNDATION Fieldbus FC INST PVC Cable, FF FC 1x2xAWG18/1 PVC 10

11 02YSY(St)CY 1x2x1.3/2.55 Li PVC FOUNDATION Fieldbus FC FLEX PVC Cable 1.2 Foundation Fieldbus 1. Stranding Bedding Static screen Braid Sheath Tensile force N Stranded bare copper wires, 19x mm (Crosssection AWG18/19) FoamskinPE, mm Two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied Tinned copper Braid Coverage approx. 70% PVC, yellow, mm Nom. 8.0mm Nom. 89 kg/km 1 Bending radius Single bending 40 mm Repeated bending 80 mm Temperature range 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 43.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Standards Electrical Data at 20 C Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± FOUNDATION Fieldbus FC FLEX PVC Cable, 02YSY(St)CY 1x2x1.3/2.55 Li PVC 11

12 Foundation Fieldbus FF FC 1x2xAWG18/7 LSHFFR FOUNDATION Fieldbus FC FLEX LSZHFR Cable Stranding Bedding Static screen Braid Sheath Colour Tensile force N Bending radius Single bending Repeated bending Temperature range stranded bare copper wires, 7x mm, (crosssection AWG18/7) foamskinpe, mm two cores gn / rd to the Pair halogen free, flame retardant thermoplastic sheathing compound acc. to EN , filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% halogen free, flame retardant thermoplastic sheathing compound acc. to EN , mm yellow Nom. 8.0 mm Nom. 83 kg/km mm 80 mm 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Standards Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 43.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Electrical Data at 20 C Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± FOUNDATION Fieldbus FC FLEX LSHFFR Cable, FF FC 1x2xAWG18/7 LSZHFR 12

13 FF FC 1x2xAWG18/1 GST PVC FOUNDATION Fieldbus FC Galvanized Steel Tape Armoured PVC Installation Cable Construction Stranding Bedding Static screen Braid Sheath Colour Wrapping Armouring Outer sheath Sheath colour Tensile force N Mechanical Properties Bending radius Single bending Repeated bending Temperature range bare copper wire, mm, (crosssection AWG18) foamskinpe, mm two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% PVC, mm yellow PP foil overlapping, mm 2 galvanized steel tapes, thickness of tapes 0.10 mm, mm PVC, mm yellow Nom mm Nom. 193 kg/km mm 180 mm 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C 1.2 Foundation Fieldbus Spur and trunk cable for fixed installation indoor and outdoor on racks in conduits, Standards IEC and IEC Cable type A acc. to FOUNDATION Fieldbus 1. Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 46 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± FOUNDATION Fieldbus FC Galvanized Steel Tape Armoured PVC Installation Cable, FF FC 1x2xAWG18/1 GST PVC 13

14 Foundation Fieldbus Standards FOUNDATION Fieldbus FC FLEX Steel Wire Braid Armoured PVC Cable Stranding Bedding Static screen Braid Sheath Colour Armouring Outer sheath Colour Tensile force N Bending radius Single bending Repeated bending Temperature range stranded bare copper wires, 7x mm, (crosssection AWG18/7) foamskinpe, mm two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% PVC, mm yellow galvanized steel wire braid, optical coverage 85%, mm PVC, mm yellow Nom mm Nom. 211 kg/km mm 120 mm 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 43.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± FOUNDATION Fieldbus FC FLEX Steel Wire Braid Armoured PVC Cable, FF FC 1x2xAWG18/7 SWB PVC 14

15 FF FC 1x2xAWG18/7 SWB LSZH FOUNDATION Fieldbus FC FLEX Steel Wire Braid Armoured LSZH Cable Construction Stranding Bedding Static screen Braid Sheath Colour Armouring Outer sheath Colour Tensile force N Mechanical Properties Bending radius Single bending Repeated bending Temperature range stranded bare copper wires, 7x mm, (crosssection AWG18/7) foamskinpe, mm two cores blue / orange to the pair LSHF, filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% LSZH, mm grey galvanized steel wire braid, optical coverage 85%, mm LSZH, mm grey Nom mm Nom. 202 kg/km mm 120 mm C to + 70 C Transport and storage C to + 70 C Installation 5 C to + 50 C 1.2 Foundation Fieldbus Spur and trunk cable for flexible installation Standards IEC and IEC Cable type A acc. to FOUNDATION Fieldbus 1. Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 43.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± FOUNDATION Fieldbus FC FLEX Steel Wire Braid Armoured LSZH Cable, FF FC 1x2xAWG18/7 SWB LSZH 15

16 Profibus PB PA FC 1x2xAWG18/1 PVC PROFIBUS PA FC INST PVC Cable Stranding Bedding Static screen Braid Sheath Colour Tensile force N bare copper wire, mm, (crosssection AWG18) foamskinpe, mm two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied tinned copper Braid Coverage approx. 70% PVC, mm black Nom. 8.0 mm Nom. kg/km 175 Bending radius single bending 40 mm repeated bending Temperature range 80 mm 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Standards Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 46 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Frequency (khz) Impedance (Ohm) ± 20 Attenuation (db/m) 0.3 Propagation delay change (μs/km) PROFIBUS PA FC INST PVC Cable, PB PA FC 1x2xAWG18/1 PVC 16

17 PB PA FC 1x2xAWG16/7 PVC PROFIBUS PA FC AWG16 FLEX PVC Cable 1.3 Profibus 1. Construction Stranding Bedding Static screen Braid Sheath Colour Tensile force N stranded bare copper wires, 7x mm, (crosssection AWG16/7) PE, mm two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% PVC, mm black or blue Nom. 9.5 mm Nom. 129 kg/km 270 Mechanical Properties Bending radius Single bending 50 mm Repeated bending mm Temperature range 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Spur and trunk cable for flexible installation indoor and outdoor on racks in conduits, FastConnectAssembly UVresistant Silicon free Oil and grease resistant Electrical Properties at 20 C Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 28.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Standards IEC and IEC Cable type A acc. to Profibus PA IEC Electrical Data at 20 C Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± Ordering Information PROFIBUS PA FC AWG16 FLEX PVC Cable, PB PA FC 1x2xAWG16/7 PVC 17

18 Profibus Standards PB PA FC 1x2xAWG16/7 LSHFFR PROFIBUS PA FC AWG16 FLEX LSHFFR Cable, Ohm Stranding Bedding Static screen Braid Sheath Colour Tensile force N Bending radius single bending repeated bending Temperature range stranded bare copper wires, 7x mm, (crosssection AWG16/7) PE, mm two cores gn / rd to the Pair halogen free, flame retardant thermoplastic sheathing compound acc. to EN , filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% halogen free, flame retardant thermoplastic sheathing compound acc. to EN , mm black Nom. 9.5 mm Nom. 143 kg/km mm mm C to + 70 C Transport and storage C to + 70 C Installation 5 C to + 50 C Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 28.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Frequency (khz) Impedance (Ohm) ± 20 Attenuation (db/m) 0.3 Propagation delay change (μs/km) PROFIBUS PA FC AWG16 FLEX LSHFFR Cable, PB PA FC 1x2xAWG16/7 LSHFFR 18

19 PB PA FC 1x2xAWG 18/19 PVC PROFIBUS PA FC FLEX PVC Cable, Ohm 1.3 Profibus 1. Construction Stranding Bedding Static screen Braid Sheath Tensile force N Stranded bare copper wires, 19x mm (Crosssection AWG18/19) FoamskinPE, mm Two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied Tinned copper Braid Coverage approx. 70% PVC, black or blue, mm Nom. 8.0 mm Nom. 89 kg/km 1 Mechanical Properties Bending radius Single bending 40 mm Repeated bending 80 mm Temperature range 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Electrical Properties at 20 C Loop resistance 43.6 Ω/km Screen resistance nominal 12 Ω/km Characteristic impedance (at khz) Ω ± 20 Ω Mutual capacitance (at 1 khz) approx. 60 nf/km Capacitance unbalance to earth max. 2 nf/km resistance 5 GΩkm Test Voltage (DC, 1 min) Core/Core and Core/Screen 1 kv Operating voltage (RMS) V Inductance (nominal) 0.70 mh/km Spur and trunk cable for flexible installation indoor and outdoor on racks in dry conduits, FastConnectAssembly UVresistant Silicon free Oil and grease resistant Standards IEC and IEC Cable type A acc. to Profibus PA IEC Electrical Data at 20 C Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± Ordering Information PROFIBUS PA FC FLEX PVC Cable, PB PA FC 1x2xAWG 18/19 PVC 19

20 Profibus Standards PB PA FC 1x2xAWG18/7 LSHFFR PROFIBUS PA FC FLEX LSHFFR Cable, Ohm Stranding Bedding Static screen Braid Sheath Colour Tensile Force N Bending radius single bending repeated bending Temperature range Transport and storage Installation stranded bare copper wires, 7x mm, (crosssection AWG18/7) foamskinpe, mm two cores gn / rd to the Pair halogen free, flame retardant thermoplastic sheathing compound acc. to EN , filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% halogen free, flame retardant thermoplastic sheathing compound acc. to EN , mm black or blue Nom. 8.0 mm Nom. 83 kg/km mm 80 mm C to + 70 C C to + 70 C 5 C to + 50 C Loop resistance Screen resistance Characteristic impedance (Nominal) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 43.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Frequency (khz) Impedance (Ohm) ± 20 Attenuation (db/m) 0.3 Propagation delay change (μs/km) x 2 x 1.2/2.55, PROFIBUS PA FC FLEX LSHFFR Cable, PB PA FC 1x2xAWG18/7 LSZHFR BK x 2 x 1.2/2.55, PROFIBUS PA FC FLEX LSHFFR Cable, PB PA FC 1x2xAWG18/7 LSZHFR BU 20

21 PB PA 1x2xAWG18/7 LSHFFR PROFIBUS PA FLEX LSZHFR Cable, Ohm Stranding Static screen Drain wire Braid Sheath Colour Tensile force N Bending radius single bending repeated bending Temperature range stranded bare copper wires, 7x mm, (crosssection AWG18/7) Polypropylene (PP) mm two cores gn / rd to the pair + two fillers PETAlFoil longitudinally applied Tinned Copper 0.5mm2 tinned copper braid, coverage approx. 70% halogen free, flame retardant thermoplastic sheathing compound acc. to EN with thermal resistance up to C mm Blue RAL5015 Nom. 7.0 mm Nom kg/km 1 40 mm 80 mm 40 C to + C Transport and storage 40 C to + C Installation 5 C to + 50 C Standards 1.3 Profibus 1. Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 43.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± PROFIBUS PA FLEX LSHFFR Cable, PB PA 1x2xAWG18/7 LSZHFR 21

22 Profibus Standards PB PA FC 1x2xAWG18/1 GST PVC PROFIBUS PA FC Galvanized Steel Tape Armoured PVC Installation Cable, Ohm Stranding Bedding Static screen Braid Sheath Colour Wrapping Armouring Outer sheath Colour Tensile force N Bending radius Single bending repeated bending Temperature range bare copper wire, mm, (crosssection AWG18) foamskinpe, mm two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied tinned copper Braid Coverage approx. 70% PVC, mm black or blue PP foil overlapping, mm 2 galvanized steel tapes, thickness of tapes 0.10 mm, mm PVC, mm black or blue Nom mm Nom. 193 kg/km mm 180 mm 40 C to + 70 C Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Loop resistance Screen resistance nominal Characteristic impedance (Nominal) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 46 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Frequency (khz) Impedance (Ohm) ± 20 Attenuation (db/m) 0.3 Propagation delay change (μs/km) PROFIBUS PA FC Galvanized Steel Tape Armoured PVC Installation Cable, PB PA FC 1x2xAWG18/1 GST PVC 22

23 PB PA FC 1x2xAWG18/7 SWB PVC PROFIBUS PA FC FLEX Steel Wire Braid Armoured PVC Cable, Ohm 1.3 Profibus 1. Stranding Bedding Static screen Braid Sheath Colour Armouring Outer sheath Colour Tensile force N Bending radius single bending repeated bending Temperature range stranded bare copper wires, 7x mm, (crosssection AWG18/7) foamskinpe, mm two cores gn / rd to the Pair PVC, filling the interstices PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% PVC, mm black or blue galvanized steel wire braid, optical coverage 85% mm PVC, mm black or blue Nom mm Nom. 211 kg/km mm 120 mm 40 C to + 70 C Standards Transport and storage 40 C to + 70 C Installation 5 C to + 50 C Loop resistance Screen resistance nominal Characteristic impedance (at khz) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 43.6 Ω/km 12 Ω/km Ω ± 20 Ω approx. 60 nf/km 2 nf/km 5 GΩkm 1 kv V 0.70 mh/km Frequency (khz) Impedance (Ohm) Attenuation (db/m) Propagation delay change (μs/km) ± PROFIBUS PA FC FLEX Steel Wire Braid Armoured PVC Cable, PB PA FC 1x2xAWG18/7 SWB PVC 23

24 Profibus Standards PB DP BASIC 1x2xAWG22/1 LSHF PROFIBUS DP Basic LSZH Cable,150 Ohm Stranding Wrapping Static screen Braid Sheath Colour Tensile force N Bending radius single bending repeated bending Max. operating voltage Bare copper wire, mm, (crosssection 0.32 mm²) foamskinpe, mm two cores gn / rd to the pair and two fillers PETFoil, mm PETAlFoil longitudinally applied tinned copper braid, coverage approx. 60% halogen free, flame retardant thermoplastic sheathing compound acc. to EN , mm violet RAL 4005 Nom. 8.0 mm Nom. 71 kg/km 60 mm 80 mm 25 C to + 80 C Relative velocity factor NVP 25 C to + 80 C Impedance (at 10 MHz) 25 C to + 80 C Loop resistance Screen resistance Characteristic impedance (Nominal) Mutual capacitance (at 1 khz) resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) 110 Ω/km 9,5 Ω/km 150 Ω ca nf/km 5 GΩkm 1 kv V Frequency (khz) Impedance (Ohm) Attenuation (db/m) 9.6 khz 38.4 khz 1 MHz 270 ± ± MHz 4 MHz 16 MHz 150 ± ± ± MHz 150 ± PROFIBUS DP Basic LSHF Cable, PB DP BASIC 1x2xAWG22/1 LSHF 24

25 PROFIBUS FC LSHFFR Cable, 150 Ohm Stranding Bedding Static screen Braid Sheath Tensile force N Bending radius single bending repeated bending Temperature range bare copper wire, mm, (crosssection 0.32 mm²) foamskinpe, mm two cores gn / rd to the Pair halogen free, flame retardant thermoplastic sheathing compound acc. to EN , filling the interstices mm PETAlFoil longitudinally applied tinned copper braid, coverage approx. 60% halogen free, flame retardant thermoplastic sheathing compound acc. to EN , violet, mm Nom. 8.0 mm Nom. 83 kg/km 60 mm 80 mm 25 C to + 80 C Transport and storage 25 C to + 80 C Installation 25 C to + 80 C Standards 1.3 Profibus 1. Loop resistance Screen resistance nominal Characteristic impedance (Nominal) Mutual capacitance (at 1 khz) resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) 110 Ω/km 9.5 Ω/km 150 Ω ca nf/km 5 GΩkm 1 kv V Frequency (khz) Impedance (Ohm) 9.6 khz 38.4 khz 1 MHz 270 ± ± MHz 150 ± 15 4 MHz 150 ± MHz 150 ± MHz 150 ± 15 Attenuation (db/m) PROFIBUS FC LSHFFR Cable, PB DP FC 1x2xAWG22/1 LSHFFR

26 Profibus Installation cable (up to inner sheath) : Halogen free and flame resistant Limited segment length (according to PROFIBUSNet Manual) FastConnectassembly UVresistant Silicon free Limited oil and grease resistance Standards PB DP FC 1x2xAWG22/1 LSHFFR + PE PROFIBUS FC LSHFFR Cable with additional PESheath, 150 Ohm Construction Stranding Bedding Static screen Braid Inner Sheath Outer Sheath Mechanical Properties Bending radius single bending repeated bending Temperature range bare copper wire, mm, (crosssection 0.32 mm²) foamskinpe, mm two cores gn / rd to the Pair halogen free, flame retardant thermoplastic sheathing compound acc. to EN , filling the interstices mm PETAlFoil longitudinally applied tinned copper braid, coverage approx. 60% halogen free, flame retardant thermoplastic sheathing compound acc. to EN , violet, mm PE, blue or black, mm Nom mm Nom. 122 kg/km 10 x D 15 x D 25 C to + 70 C Transport and storage 25 C to + 70 C Installation 25 C to + 50 C Electrical Properties at 20 C Basic cable: IEC , IEC , IEC , IEC /2 Loop resistance Screen resistance Characteristic impedance (Nominal) Mutual capacitance (at 1 khz) resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) 110 Ω/km 9.5 Ω/km 150 Ω ca nf/km 5 GΩkm 1 kv V Electrical Data at 20 C Frequency (khz) Impedance (Ohm) 9.6 khz 38.4 khz 1 MHz 270 ± ± MHz 150 ± 15 4 MHz 150 ± MHz 150 ± MHz 150 ± 15 Attenuation (db/m) Ordering Information x 2 x 0.64/ , PROFIBUS FC LSZHFR Cable with additional PESheath, PB DP FC 1x2xAWG22/1 LSHFFR + PE x 2 x 0.64/ , PROFIBUS FC LSZHFR Cable with additional PESheath, PB DP FC 1x2xAWG22/1 LSHFFR + PE 26

27 PB DP FC 1x2xAWG22/1 PE PROFIBUS DP FC PE Sheathed Cable, 150 Ohm 1.3 Profibus 1. Stranding Bedding Static screen Braid Sheath Outer sheath Colour Tensile force N Bending radius single bending repeated bending Temperature range bare copper wire, mm, (crosssection 0.32 mm²) foamskinpe, mm two cores gn / rd to the Pair halogen free, flame retardant thermoplastic sheathing compound acc. to EN , filling the interstices mm PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% halogen free, flame retardant thermoplastic sheathing compound acc. to EN , violet, RAL mm PE, mm black, RAL 05 Nom mm Nom. 113 kg/km mm 120 mm C to + 70 C Transport and storage C to + 70 C Installation 5 C to + 50 C Standards Loop resistance Screen resistance nominal Characteristic impedance (nominal) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 110 Ω/km 12 Ω/km 150 Ω approx nf/km 1.5 nf/km 5 GΩkm 1 kv V 0. mh/km Frequency (khz) Impedance (Ohm) 9.6 khz 38.4 khz 1 MHz 270 ± ± MHz 150 ± 15 4 MHz 150 ± MHz 150 ± MHz 150 ± 15 Attenuation (db/m) PROFIBUS DP FC PE Sheathed Cable, PB DP FC 1x2xAWG22/1 PE 27

28 Profibus Standards PB DP FC 1x2xAWG24/19 PUR PROFIBUS DP FC FLEXPUR Cable, 150 Ohm Stranding Bedding Wrapping Static screen Braid Sheath Colour Tensile force N Bending radius single bending repeated bending Temperature range Stranded bare copper wires, AWG24/7, 19 x0.13, mm, (Crosssection 0.25 mm²) foamskinpe, mm two cores gn / rd to the pair PVC, filling the interstices, mm non woven Polyestertape PETAlFoil spirally applied tinned copper braid, coverage approx. 70% PUR, mm violet, RAL 4005 Nom. 8.0 mm nom. 70 kg/km mm 120 mm 40 C to + 70 C Transport and storage 40 C to + 60 C Installation 40 C to + 60 C Loop resistance Screen resistance nominal Characteristic impedance (Nominal) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 135 Ω/km 12 Ω/km 150 Ω < nf/km 1.5 nf/km 5 GΩkm 1 kv V 0. mh/km Frequency (khz) Impedance (Ohm) 9.6 khz 38.4 khz 1 MHz 270 ± ± MHz 150 ± 15 4 MHz 150 ± MHz 150 ± MHz 150 ± 15 Attenuation (db/m) PROFIBUS DP FC FLEXPUR Cable, PB DP FC 1x2xAWG24/19 PUR

29 PB DP FC 1x2xAWG24/19 TRAILING PUR PROFIBUS DP FC TrailingCable, 150 Ohm Stranding Wrapping Bedding Wrapping Static screen Braid Sheath Colour Tensile force N Marking Bending radius single bending repeated bending Bending cycles (at 20 C) Temperature range stranded bare copper wires, 19x0.13, mm, (crosssection 0.25 mm²) foamskinpe, mm two cores gn / rd to the Pair PETFoil PVC, filling the interstices 0 5,4 mm non woven Polyestertape PETAlFoil spirally applied tinned copper braid, coverage approx. 70% PUR, mm petrol Nom. 8.0 mm Nom. 70 kg/km 40 mm 120 mm C to + 60 C Transport and storage 40 C to + 60 C Installation 40 C to + 60 C Standards 1.3 Profibus 1. Loop resistance Screen resistance Characteristic impedance (Nominal) Mutual capacitance (at 1 khz) resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) 133 Ω/km 14 Ω/km 150 Ω ca nf/km 5 GΩkm 1 kv V Frequency (khz) Impedance (Ohm) 9.6 khz 38.4 khz 1 MHz 270 ± ± MHz 150 ± 15 4 MHz 150 ± MHz 150 ± MHz 150 ± 15 Attenuation (db/m) PROFIBUS DP FC TrailingCable, PB DP FC 1x2xAWG24/19 TRAILING PUR

30 Profibus Standards PB DP FC 1x2xAWG22/1 SWB LSHF PROFIBUS DP FC Steel Wire Braid Armoured LSHF Cable, 150 Ohm Stranding Bedding Static screen Braid Sheath Armouring Outer sheath Tensile force N Bending radius single bending repeated bending Temperature range bare copper wire, mm, (crosssection 0.32 mm²) foamskinpe, mm two cores gn / rd to the Pair halogen free, flame retardant thermoplastic sheathing compound acc. to EN , filling the interstices mm PETAlFoil longitudinally applied tinned copper braid, coverage approx. 70% halogen free, flame retardant thermoplastic sheathing compound acc. to EN , violet, mm galvanized steel wire braid, optical coverage 85% mm halogen free, flame retardant thermoplastic sheathing compound acc. to EN , violet, RAL mm Nom mm Nom. 208 kg/km mm 120 mm C to + 70 C Transport and storage C to + 70 C Installation 5 C to + 50 C Loop resistance Screen resistance nominal Characteristic impedance (nominal) Mutual capacitance (at 1 khz) Capacitance unbalance to earth max. resistance Test Voltage (DC, 1 min) Core/Core and Core/Screen Operating voltage (RMS) Inductance (nominal) 110 Ω/km 12 Ω/km 150 Ω approx nf/km 1.5 nf/km 5 GΩkm 1 kv V 0. mh/km Frequency (khz) Impedance (Ohm) 9.6 khz 38.4 khz 1 MHz 270 ± ± MHz 150 ± 15 4 MHz 150 ± MHz 150 ± MHz 150 ± 15 Attenuation (db/m) PROFIBUS DP FC Steel Wire Braid Armoured LSHF Cable, PB DP FC 1x2xAWG22/1 SWB LSHF

31 UC0 Cat.5e F/UTP SWB LSZHFR Category cable for demanding environments 1.4 Industrial Ethernet 1. Construction Twisting Overall screen Drain Wire Inner Sheath Armouring Outer sheath Sheath colour Bare copper wire Ø 0.51 mm (AWG24) PE, Nom. Ø 1.03 mm 2 cores to the pair Aluminium Polyester Tape Tinned Copper ; Ø ± mm LSZHFR 0.3mm Galvanised Steel Braid, Coverage 80% LSZHFR Black Bending radius Installation 8 x D Temperature range During operation 10 C to + 60 C During installation 10 C to + 60 C Electrical Properties at at 20 C± 5 C loop resistance 170 Ω/km Resistance unbalance 2% Characteristic Impedence 11Mhz Ω ± 15 ohm Mutual capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair to ground) 0 pf/km Nominal Velocity of Propagation 0.69c environment. Standards EIA/TIA 568C; ISO/IEC nd ed.; IEC Electrical Data Nominal at 20 C Pair to Pair Power Sum F Max. Ins. Loss Min. Return loss Min. NEXT Min ELFEXT Min. NEXT Min ELFEXT ELFEXT (MHZ) (db/m) (db) (db/m) (db/m) (db/m) (db/m) (db/m) B UC 0 Cat 5e F/UTP 24 AWG LSZHFR SWB 500m/drum 31

32 Industrial Ethernet UC400 Cat.6 F/UTP SWB LSZHFR Category cable for demanding environments Twisting Overall Screen Inner Sheath Armouring Outer Sheath Sheath Colour Bare copper wire Ø 0.57 mm (AWG23) PE, Nom. Ø 0.95 mm 2 cores to the pair Aluminum Polyester Tape Special Flame retardant and halogen free LSZHFR 0.3mm Galvanised Steel Braid, Coverage 80% Black Special Flame retardant and halogen free LSZHFR Black Bending radius Temperature range Installation During operation During installation 8 X D 10 C to + 60 C 10 C to + 60 C Standards Loop resistance Resistance unbalance resistance Mutual capacitance Capacitance unbalance Test voltage 110 Ω/km 12 Ω/km (500 V) at 800 Hz (pair/ground) (DC, 1 min) core/core and core/screen 176 Ω/km 2% 2000 MΩ*km Nom. 43 nf/km 1500 pf/km 0 V F (MHZ) Return loss (db) Attenuation NEXT ACR PSNEXT ELFEXT PSELFEXT (db/m) (db) (db/m) (db) (db/m) (db/m) B UC 400 Cat 6 F/UTP 23 AWG LSZHFR SWB, IEC m/drum 32

33 IE ToughCat 5e LSHFFR S/FTP Installation Cable 4x2xAWG24/7 for tougher environments 1.4 Industrial Ethernet 1. Construction Twisting Cable lay up Pair screen Overall screen Sheath Colour Tensile force N Stranded copper wire, cross section 0.22 mm² (AWG24/7) PE, Ø 1.4 mm 2 cores to the pair 4 pairs Allaminated plastic foil around each pair Copper braid, tinned Ø 6.2 mm Oil resistant, Fire retardant and halogen free LSZHFR (SHF1), diameter 7.7 mm Grey RAL 7035 Nom. 7.7 mm Nom. 68 kg/km Bending radius Temperature range Fire load Maximum tensile load Electrical Properties at 20 C Without load With load During operation During installation 4 pair During operation During installation DC loop resistance resistance (500 V) Capacitance at 800 Hz Capacitance unbalance (pair to ground) Mean Characteristic MHz Nominal velocity of propagation Propagation delay Delay skew Transfer impedance at 1 MHz at 10 MHz at MHz Coupling attenuation 8 x D 4 x D 40 C to + 85 C 15 C to + 50 C 670 MJ/km No load N 158 Ω/km Resistance unbalance 2% 5000 MΩxkm Nom. 43 nf/km 1500 pf/km ± 5 Ω 0.75c 450 ns/ m 15 ns/ m 10 mω /m 8 mω /m 10 mω /m 85 db Cat5e S/FTP electrical and mechanical environment, including ships and offshore units. Standards EN Det Norske Veritas (DNV) specification No and Lloyd Register approval, system, 2002 Chemical Resistance Certification and Lloyd Register Nominal Transmission Characteristics at 20 C F Attenuation NEXT ACR Return loss PSNEXT (MHZ) (db/m) (db) (db/m) (db) (db) PSACR (db/m) ELFEXT (db/m) PSELFEXT (db/m) S/FTP Installation Cable 4x2xAWG24/7 for tougher environments, IE ToughCat 5e LSHFFR 500m/drum S/FTP Installation Cable 4x2xAWG24/7 for tougher environments, IE ToughCat 5e LSHFFR 33

34 Industrial Ethernet IE ToughCat 5e LSHFFR MUD S/FTP Installation Cable 4x2xAWG24/7 for tougher environments Twisting Cable lay up Pair screen Overall screen Inner Sheath Colour Outer sheath Colour Tensile force N Stranded copper wire, cross section 0.22 mm² (AWG24/7) PE, Ø 1.4 mm 2 cores to the pair 4 pairs Allaminated plastic foil around each pair Copper braid, tinned Ø 6.2 mm Oil resistant, Fire retardant and halogen free LSZHFR (SHF1), diameter 7.7 mm Grey RAL 7035 MUD protecting, diameter 9.5 mm Grey RAL 7024 Nom. 9.5 mm Nom. kg/km Cat5e S/FTP Standards EN , EN ISO/IEC 11801, IEC IEC 61034, IEC IEC , IEC /2 Chemical Resistance Bending radius Temperature range Fire load Maximum tensile load Without load With load During operation During installation 4 pair During operation During installation DC loop resistance resistance (500 V) Capacitance at 800 Hz Capacitance unbalance (pair to ground) Mean Characteristic MHz Nominal velocity of propagation Propagation delay Delay skew Transfer impedance at 1 MHz at 10 MHz at MHz Delay skew 8 x D 4 x D 40 C to + 85 C 15 C to + 50 C (on request) MJ/km No load N 158 Ω/km Resistance unbalance 2% 5000 MΩxkm Nom. 43 nf/km 1500 pf/km ± 5 Ω 0.75c 450 ns/ m 15 ns/ m 10 mω /m 8 mω /m 10 mω /m 85 db F Attenuation NEXT ACR Return loss PSNEXT (MHZ) (db/m) (db) (db/m) (db) (db) PSACR (db/m) ELFEXT (db/m) PSELFEXT (db/m) S/FTP Installation Cable 4x2xAWG24/7 for tougher environments, 500m/drum IE ToughCat 5e LSHFFR MUD S/FTP Installation Cable 4x2xAWG24/7 for tougher environments, IE ToughCat 5e LSHFFR MUD 34

35 IE ToughCat 7 LSHFFR S/FTP Installation Cable 4x2xAWG23/7 for tougher environments 1.4 Industrial Ethernet 1. Construction Twisting Cable lay up Pair screen Overall screen Sheath Colour Tensile force N Stranded copper wire, cross section 0.27 mm² (AWG23/7) PE, Ø 1.6 mm 2 cores to the pair 4 pairs Allaminated plastic foil around each pair Copper braid, tinned Ø 6.6 mm Oil resistant, Fire retardant and halogen free LSZHFR (SHF1), diameter 8.1 mm Grey RAL 7035 Nom. 8.1 mm Nom. 75 kg/km Mechanical Properties Bending radius Temperature range Fire load Maximum tensile load Electrical Properties at 20 C Without load With load During operation During installation 4 pair During operation During installation DC loop resistance resistance (500 V) Capacitance at 800 Hz Capacitance unbalance (pair to ground) Mean Characteristic MHz Nominal velocity of propagation Propagation delay Delay skew Transfer impedance at 1 MHz at 10 MHz at MHz Coupling attenuation 8 x D 4 x D 40 C to + 85 C 15 C to + 50 C 670 MJ/km No load N 138 Ω/km Resistance unbalance 2% 5000 MΩxkm Nom. 43 nf/km 1500 pf/km ± 5 Ω 0.76c 450 ns/ m 15 ns/ m 10 mω /m 8 mω /m 10 mω /m 85 db Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN ; EN ISO/IEC 11801; IEC Det Norske Veritas (DNV) specification No EC , IEC , IEC , IEC /2 Chemical Resistance Mineral oils IRM 2 (IEC ) : 7 days/23 C, 4 hours/70 C 7 days/23 C, 4 hours/70 C Certification This cable is certified by: Det Norske Veritas (DNV) and American Bureau of Shipping (ABS) Nominal Transmission Characteristics at 20 C F Attenuation NEXT ACR Return loss PSNEXT (MHZ) (db/m) (db) (db/m) (db) (db) PSACR (db/m) PSELFEXT (db/m) PSELFEXT (db/m) Ordering Information S/FTP Installation Cable 4x2xAWG23/7 for tougher environments, IE ToughCat 7 LSHFFR 500m/drum S/FTP Installation Cable 4x2xAWG23/7 for tougher environments, IE ToughCat 7 LSHFFR 35

36 Industrial Ethernet IE ToughCat 7 LSHFFR MUD S/FTP Installation Cable 4x2xAWG23/7 for tougher environments Construction Twisting Cable lay up Pair screen Overall screen Inner Sheath Colour Outer sheath Colour Tensile force N Stranded copper wire, cross section 0.27 mm² (AWG23/7) PE, Ø 1.6 mm 2 cores to the pair 4 pairs Allaminated plastic foil around each pair Copper braid, tinned Ø 6.6 mm Oil resistant, Fire retardant and halogen free LSZHFR (SHF1), diameter 8.1 mm Grey RAL 7035 MUD protecting, diameter 10.1 mm Grey RAL 7024 Nom mm Nom. 112 kg/km Cat7 S/FTP Standards EN ; EN ISO/IEC 11801; IEC Det Norske Veritas (DNV) specification No Chemical Resistance 7 days/ C Bending radius Temperature range Fire load Maximum tensile load Without load With load During operation During installation 4 pair During operation During installation DC loop resistance resistance (500 V) Capacitance at 800 Hz Capacitance unbalance (pair to ground) Mean Characteristic MHz Nominal velocity of propagation Propagation delay Delay skew Transfer impedance at 1 MHz at 10 MHz at MHz Coupling attenuation 8 x D 4 x D 40 C to + 85 C 15 C to + 50 C (on request) MJ/km No load N 138 Ω/km Resistance unbalance 2% 5000 MΩxkm Nom. 43 nf/km 1500 pf/km ± 5 Ω 0.76c 450 ns/ m 15 ns/ m 10 mω /m 8 mω /m 10 mω /m 85 db F Attenuation NEXT ACR Return loss PSNEXT (MHZ) (db/m) (db) (db/m) (db) (db) PSACR (db/m) PSELFEXT (db/m) PSELFEXT (db/m) S/FTP Installation Cable 4x2xAWG23/7 for tougher environments, 500m/drum IE ToughCat 7 LSHFFR MUD S/FTP Installation Cable 4x2xAWG23/7 for tougher environments, IE ToughCat 7 LSHFFR MUD 36

37 IE ToughCat 7S* Armoured S/FTP Installation Cable for tougher environments 1.4 Industrial Ethernet 1. Construction Twisting Pair screen Cable lay up Screen Inner Sheath Outer sheath Armouring Outer sheath Mechanical Properties Bending radius Temperature range Fire load Maximum tensile load Electrical Properties at 20 C ± 5 C Solid copper wire, Ø 0.56 mm (AWG 23) foamskin PE, Ø 1.4 mm 2 cores to the pair Allaminated plastic foil 4 pairs (PiMF) to the core copper braid, tinned Oil resistant, Fire retardant and halogen free LSZHFR (SHF1) Grey RAL7035 Galvanized steel wire braid, Wire diameter 0,25mm Oil resistant, Fire retardant and halogen free LSZHFR (SHF1) Nom mm Nom. 168 kg/km Installation Installed During operation During installation 4 pair During operation During installation 8 x D 4 x D 40 C to + 85 C 15 C to + 50 C 1540 MJ/km No load 200 N Loop resistance 150 Ω/km Resistance unbalance 2% resistance (500 V) 5000 MΩxkm Mutual capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair/ground) 1500 pf/km Characteristic impedance (1 MHz) ± 5 Ω ( 250) MHz ± 10 Ω ( ) MHz ± 15 Ω Nominal velocity of propagation ca. 79 % Propagation delay 570 ns/m Delay skew 9 ns/m Test voltage (DC, 1 min) core/core and core/screen 0 V Transfer impedance(grade 1) Coupling attenuation at 1 MHz at 10 MHz at MHz at MHz 10 mω/m 10 mω/m 10 mω/m 20 mω/m 85 db Cat7 S/FTP including ships and offshore units. Standards EN ; EN ISO/IEC 11801; IEC Det Norske Veritas (DNV) specification No IEC /2 Chemical Resistance Certification Electrical Data (Nominal) acc. to Cat.7 (at 20 C) F Attenuation NEXT PSNEXT ACR PSACR (MHZ) (db/m) (db) (db) (db/m) (db/m) ELFEXT (db/m) PSELFEXT (db/m) Retuen loss (db/m) S/FTP Installation Cable for tougher environments, IE ToughCat 7S* Armoured 500m/drum 37

38 Industrial Ethernet IE SuperCat 7 HS23 Cat.7 LSHF Water resistant S/FTP Installation Cable 4x2xAWG23/1 for Indoor/Outdoor use Construction Twisting Pair screen Cable lay up Cable core filling Screen Sheath Colour Tensile force N Solid bare copper wire, Ø 0.55 mm (AWG 23) Foamskin PE, Ø 1.45 mm 2 cores to the pair, WBC filled Allaminated plastic foil 4 pairs (PiMF) to the core, swelling yarn and tape Special Waterproofing/compound to prevent moisture migration*). To prevent water penetration and to ensure electrical properties even in continuous wet conditions. Copper braid, tinned LSZH, UV stabilized, diameter 8.7 mm Black, RAL 11 Nom. 8.7 mm Nom. 0 kg/km penetration Standards EN ; EN ISO/IEC 11801; IEC Water Penetration Rating IEC /2 Bending radius Temperature range Fire load Maximum tensile load During operation During installation During operation During installation During operation During installation 4 x Outer diameter 8 x Outer diameter 40 C to + 60 C 10 C to + 50 C 838 MJ/km N Loop resistance 165 Ω/km Resistance unbalance 2% resistance (500 V) 2000 MΩ*km Mutual capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair/ground) 1500 pf/km Characteristic impedance (1 MHz) ( ± 15) Ω ( 250) MHz ( ± 18) Ω ( ) MHz ( ± 25) Ω Nominal velocity of propagation ca. 79 % Propagation delay 550 ns/m Delay skew 10 ns/m Test voltage (DC, 1 min) core/core and core/screen 0 V Transfer impedance at 1 MHz 20 mω/m at 10 MHz mω/m at MHz 40 mω/m at MHz 200 mω/m Delay skew 75 db Nominal Transmission Characteristics at 20 C F Attenuation NEXT PSNEXT * ACR PSACR (MHZ) (db/m) (db) (db) (db/m) (db/m) ELFEXT (db/m) PSELFEXT (db/m) Return loss (db) Water resistant S/FTP Installation Cable 4x2xAWG23/1 for Indoor/Outdoor use, IE SuperCat 7 HS23 Cat.7 LSHF Water resistant S/FTP Installation Cable 4x2xAWG23/1 for Indoor/Outdoor use, IE SuperCat 7 HS23 Cat.7 LSHF 500m/drum 38

39 IE UC0 SS23 Cat.7 (L)H LSHFFR IE S/FTP cable 4x2xAWG23/1 with LSHFFR moisture barrier sheath 1.4 Industrial Ethernet 1. Construction Twisting Pair screen Cable lay up Screen Sheath Colour Tensile force N bare copper wire, Ø 0.56 mm (AWG 23) foamskin PE, Ø 1.4 mm 2 cores to the pair Allaminated plastic foil 4 pairs (PiMF) to the core copper braid, tinned aluminum tape connected with halogen free, flame retardant thermoplastic sheathing compound acc. to EN , wall thickness 1.5 mm black RAL 05 Nom. 9.5 mm Nom. 114 kg/km 350 Bending radius Temperature range Without load With load During operation During installation 40 mm 80 mm 20 C to + 60 C 0 C to + 50 C Loop resistance 165 Ω/km Resistance unbalance 2% resistance (500 V) 5000 MΩ*km Mutual capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair/ground) 1500 pf/km Mean characteristic impedance MHz ± 5 Ω Nominal velocity of propagation ca. 79 % Propagation delay 427 ns/m Delay skew 12 ns/m Test voltage Transfer impedance (DC, 1 min) core/core and core/screen at 1 MHz 0 V 10 mω/m at 10 MHz at MHz at MHz 10 mω/m mω/m 60 mω/m Coupling attenuation 85 db Standards EN ; EN ISO/IEC 11801; IEC IEC /2 F Attenuation NEXT PSNEXT ACR PSACR (MHZ) (db/m) (db) (db/m) (db) (db) , , ELFEXT (db/m) PSELFEXT (db/m) Return loss (db/m) IE S/FTP cable 4x2xAWG23/1 with LSHFFR moisture barrier sheath, IE UC0 SS23 Cat.7 (L)H LSHFFR IE S/FTP cable 4x2xAWG23/1 with LSHFFR moisture barrier sheath, IE UC0 SS23 Cat.7 (L)H LSHFFR 500m/drum 39

40 Industrial Ethernet IE UC0 SS23 Cat.7 PE IE S/FTP cable 4x2xAWG23/1 with PE sheath Construction Twisting Pair screen Cable lay up Screen Sheath Colour Tensile force N bare copper wire, Ø 0.56 mm (AWG 23) foamskin PE, Ø 1.4 mm 2 cores to the pair Allaminated plastic foil 4 pairs (PiMF) to the core copper braid, tinned PE, for outdoor installation black, RAL 05 Nom. 8.4 mm Nom. 95 kg/km 340 EN ; EN ISO/IEC 11801; IEC Bending radius Temperature range Without load With load During operation During installation 40 mm 80 mm 55 C to + 60 C 20 C to + 50 C Loop resistance 165 Ω/km Resistance unbalance 2% resistance (500 V) 5000 MΩ*km Mutual capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair/ground) 1500 pf/km Characteristic impedance (1 MHz) ( ± 15) Ω Nominal velocity of propagation Propagation delay ( 250) MHz ( ) MHz ( ± 18) Ω ( ± 25) Ω ca. 79 % 427 ns/m Delay skew 12 ns/m Test voltage (DC, 1 min) core/core and core/screen 0 V Transfer impedance at 1 MHz at 10 MHz at MHz at MHz 10 mω/m 10 mω/m mω/m 60 mω/m Coupling attenuation 85 db F Attenuation NEXT PSNEXT ACR PSACR (MHZ) (db/m) (db) (db) (db/m) (db/m) ELFEXT (db/m) PSELFEXT (db/m) Return loss (db) IE S/FTP cable 4x2xAWG23/1 with PE sheath, IE UC0 SS23 Cat.7 PE 500m/drum IE S/FTP cable 4x2xAWG23/1 with PE sheath, IE UC0 SS23 Cat.7 PE 40

41 IE UC0 SS23 Cat.7 PUR IE S/FTP cable 4x2xAWG23/1 with abrasion and oil resistant PUR sheath 1.4 Industrial Ethernet 1. Construction Twisting Pair screen Cable lay up Screen Sheath Colour Tensile force N Marking Bending radius Temperature range bare copper wire, Ø 0.56 mm (AWG 23) foamskin PE, Ø 1.4 mm 2 cores to the pair Allaminated plastic foil 4 pairs (PiMF) to the core copper braid, tinned PUR, oil resistant green RAL 6018 Nom. 7.5 mm Nom. 92 kg/km 340 Without load With load During operation During installation mm 60 mm C to + 75 C 0 C to + 50 C Loop resistance 150 Ω/km Resistance unbalance 2% resistance (500 V) 5000 MΩ*km Mutual capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair/ground) 1500 pf/km Characteristic impedance (1 MHz) ( ± 5) Ω Nominal velocity of propagation Propagation delay ( 250) MHz ( ) MHz ( ± 10) Ω ( ± 15) Ω ca. 79 % 427 ns/m Delay skew 9 ns/m Test voltage (DC, 1 min) core/core and core/screen 0 V Transfer impedance at 1 MHz at 10 MHz at MHz at MHz 5 mω/m 5 mω/m 10 mω/m 20 mω/m Coupling attenuation 85 db Standards EN ; EN ISO/IEC 11801; IEC IEC ; IEC ; IEC F Attenuation NEXT PSNEXT ACR PSACR (MHZ) (db/m) (db) (db) (db/m) (db/m) ELFEXT (db/m) PSELFEXT (db/m) Return loss (db) IE S/FTP cable 4x2xAWG23/1 with abrasion and oil resistant PUR sheath, IE UC0 SS23 Cat.7 PUR IE S/FTP cable 4x2xAWG23/1 with abrasion and oil resistant PUR sheath, IE UC0 SS23 Cat.7 PUR 500m/drum 41

42 Industrial Ethernet 0BaseT; 10GBaseT Standards EIA/TIA 568A; ISO/IEC nd ed.; IEC EN ; EN IEC ; IEC ; IEC Chemical Resistance Oil resistant against Mineral oil, ASTM oil The sheath material is tested in Hydraulic oil ARAL VITAM 32, Mobil DTE 13 M, Gear oil ARAL DEGOL BG Plus 320 and Tribol 1710/320. IE UC0 SS27 Cat.7 PUR IE S/FTP patch cable 4x2xAWG27/7 with abrasion and oil resistant PUR sheath Construction Twisting Pair screen Cable lay up Screen Sheath Colour Tensile force N Marking Bending radius Temperature range UV resistance of sheath material Ozone resistance Smoke density Corrosivity stranded bare copper wires, Ø 0.42 mm (AWG 27/7) foamskin Polyethylene, Ø 0.98 mm 2 cores to the pair Allaminated plastic foil 4 pairs (PiMF) to the core copper braid, tinned PUR red Nom. 5.9 mm Nom. 34 kg/km Without load With load During operation During installation 25 mm 50 mm 35 C to + 75 C 5 C to + 50 C acc. to IEC acc. to EN , clause 8 acc. to EN , IEC and 2 acc. EN and 2, IEC and 2 Loop resistance 340 Ω/km Resistance unbalance 3% resistance (500 V) 2000 MΩ*km Mutual capacitance at 800 Hz Nom. 43 nf/km Capacitance unbalance (pair/ground) 1500 pf/km Characteristic impedance (1 MHz) ( ± 15) Ω Nominal velocity of propagation Propagation delay ( 250) MHz ( ) MHz ( ± 18) Ω ( ± 25) Ω ca. 79 % 427 ns/m Delay skew 12 ns/m Test voltage (DC, 1 min) core/core and core/screen 0 V Transfer impedance at 1 MHz at 10 MHz 25 mω/m 15 mω/m Coupling attenuation at MHz mω/m 75 db Electrical Data (Nominal) acc. to Cat.7 (at 20 C) F Attenuation NEXT PSNEXT ACR (MHZ) (db/10m) (db) (db) (db/m) ELFEXT (db/m) PSELFEXT (db/m) Return loss (db) Ordering Information IE S/FTP patch cable 4x2xAWG27/7 with abrasion and oil resistant PUR sheath, IE UC0 SS27 Cat.7 PUR IE S/FTP patch cable 4x2xAWG27/7 with abrasion and oil resistant PUR sheath, IE UC0 SS27 Cat.7 PUR 500m/drum 42

43 JAMAK Symmetrical data cable for industrial control equipment identification Stranding Stranding to core Pair shielding Overall shielding Outer sheath Tinned stranded copper 7x 0.29 mm PE (2Y) aconductor blue; bconductor red 2 conductors to pair (0+4) Laminated ALfoil + copper drain wire 0.5 mm 2 2pairs 48pairs: Laminated ALfoil + copper drain wire 0.5 mm 2, 1pair: without overall shielding PVC (Y), grey Nom. 7.2(2pair) 28.0(48pair) mm Nom. 60(2pair) 980(48pair) kg/km 1.5 JAMAK Industrial Data 1. Operating temperature Min. Installation temperature Loop resistance resistance (at 500 V, 1 min.) Capacitance at 800 Hz Max. operating voltage Relative velocity factor NVP Impedance (at 10 MHz) Frequency [khz] C to + 70 C 5 C 81 Ω/km 2 GΩ*km 85 nf/km 75 V Ω +/ 10 % Attenuation [db/ m] x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK DX 2x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK DX 2x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK 200m/drum DX 4x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK DX 4x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK 200m/drum 5530DX 8x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK DX 8x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK 500m/drum DX 12x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK DX 24x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK 500m/drum DX 24x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK DX 48x(2+1)x0.5, Symmetrical data cable for industrial control equipment, JAMAK 500m/drum 43

44 JAMAK Industrial Data JAMAK C LSZH Symmetrical Data Cable for Industrial Control Equipment Construction identification Stranding Stranding to core Pair shielding Overall shielding Outer sheath Mechanical Properties Stranded tinned copper 7x 0.29 mm PE (2Y) aconductor blue; bconductor red 2 conductors to pair (0+4) Laminated ALfoil + copper drain wire 0.5 mm 2 2 Laminated ALfoils with inner copper drain wire 0.5 mm 2 LSZH (H), grey (RAL 7035), light resistant Nom. 7.5(2pair).5(48pair) mm Nom. 70(2pair) 0(48pair) kg/km These halogenfree, flame retardant and symmetrical data transmission cables are used in control and supervision center for industrial sites. They are suitable for fixed installation inside housings. IEC ; IEC ; IEC Operating temperature Min. Installation temperature Electrical Properties at 20 C Loop resistance resistance (at 500 V, 1 min.) Capacitance at 800 Hz Max. operating voltage Relative velocity factor NVP Impedance (at 10 MHz) Frequency [khz] C to + 70 C 5 C 81 Ω/km 2 GΩ*km 85 nf/km 75 V Ω +/ 10 % Attenuation [db/ m] Ordering Information DX 2x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK C LSZH 5520DX 4x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK C LSZH 5500DX 8x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK C LSZH DX 24x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK C LSZH DX 24x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK C LSZH DX 48x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK C LSZH 500m/drum 44

45 JAMAK HF Symmetrical Data Cable for Industrial Control Equipment Construction identification Stranding Stranding to core Pair shielding Overall shielding Outer sheath Tinned stranded copper 7x 0.29 mm PE (2Y) aconductor blue; bconductor red 2 conductors to pair (0+4) Laminated ALfoil + copper drain wire 0.5 mm 2 Laminated ALfoil + copper drain wire 0.5 mm 2 LSZH (H), grey Nom. 7.5(2pair).5(48pair) mm Nom. 70(2pair) 1500(48pair) kg/km 1.5 JAMAK Industrial Data 1. Mechanical Properties Operating temperature Min. Installation temperature Electrical Properties at 20 C Loop resistance resistance (at 500 V, 1 min.) Capacitance at 800 Hz Max. operating voltage Relative velocity factor NVP Impedance (at 10 MHz) Frequency [khz] C to + 70 C 5 C 81 Ω/km 2 GΩ*km 85 nf/km 75 V Ω +/ 10 % Attenuation [db/ m] These symmetrical data transmission cables are used in control and supervision center for industrial sites. They are suitable for fixed installation inside housings. IEC ; IEC ; IEC Ordering Information JAMAK HF 2x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK HF JAMAK HF 4x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK HF JAMAK HF 8x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK HF JAMAK HF 12x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK HF JAMAK HF 24x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK HF JAMAK HF 48x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK HF 500m/drum 45

46 JAMAK Industrial Data JAMAK ARM Symmetrical Data Cable for Industrial Control Equipment identification Stranding Stranding to core Pair shielding Overall shielding Inner sheath Armouring Outer sheath Stranded tinned copper 7x 0.29 mm PE (2Y) aconductor blue; bconductor red 2 conductors to pair (0+4) Laminated ALfoil + copper drain wire 0.5 mm2 Laminated ALfoil + copper drain wire 0.5 mm2 PVC (Y), grey Steel tape, helically wounded PE (2Y), black Nom. 13(4pair) 34.5(48pair) mm Nom. 250 (4pair) 1500(48pair) kg/km Water Penetration Rating Operating temperature Min. Installation temperature Loop resistance resistance (at 500 V, 1 min.) Capacitance at 800 Hz Max. operating voltage Relative velocity factor NVP Impedance (at 10 MHz) Frequency [khz] C to + 70 C 5 C 81 Ω/km 2 GΩ*km 85 nf/km 75 V Ω +/ 10 % Attenuation [db/ m] DX 4x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK ARM DX 8x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK ARM DX 12x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK ARM 55DX 24x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK ARM 55DX 48x(2+1)x0.5, Symmetrical Data Cable for Industrial Control Equipment, JAMAK ARM 46

47 NOMAK Symmetrical data cable for industrial control equipment identification Stranding Stranding to core Overall shielding Outer sheath Stranded tinned copper 7x0,29 mm PVC (Y) aconductor orange; bconductor white (with number printing) 2 conductors to pair (0+4) Laminated ALfoil + tinned copper drain wire 0.5 mm2 PVC (Y), grey (RAL 7035) Nom. 6.7(2pair) 23.5(48pair) mm Nom. 52(2pair) 745(48pair) kg/km 1.6 NOMAK Industrial Data 1. Operating temperature Min. Installation temperature Loop resistance resistance (at 500 V, 1 min.) Capacitance at 800 Hz for 2 and 4 pairs Max. operating voltage Relative velocity factor NVP Impedance (at 10 MHz) Frequency [khz] C to + 70 C 5 C 81 Ω/km MΩ*km 85 nf/km nf/km 75 V 0.60 Ω +/ 10 % Attenuation [db/ m] DO 2x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK DW 2x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK 200m/drum DO 4x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK DW 4x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK 200m/drum DX 8x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK 5540DX 12x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK DX 24x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK DX 48x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK 47

48 NOMAK Industrial Data NOMAK E Symmetrical data cable for industrial control equipment identification Pair 1 Pair 2 Pair 3 Pair 4 Stranding Stranding to core Overall shielding Outer sheath Operating temperature Min. Installation temperature Stranded tinned copper 7x0,29 mm PVC (Y) aconductor bconductor Blue Red Grey Yellow Green Brown White Black 2 conductors to pair (0+4) each 4pair bundle with numbered Laminated ALfoil + tinned copper drain wire 0.5 mm 2 PVC (Y), grey (RAL 7035) Nom. 7.0(2pair) 23.5(48pair) mm Nom. 55(2pair) 747(48pair) kg/km C to + 70 C 5 C Loop resistance resistance (at 500 V, 1 min.) Capacitance at 800 Hz for 2 and 4 pairs Max. operating voltage Relative velocity factor NVP Impedance (at 10 MHz) Frequency [khz] Ω/km MΩ*km 85 nf/km nf/km 75 V 0.60 Ω +/ 10 % Attenuation [db/ m] x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK E x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK E 200m/drum DX 8x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK E DX 12x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK E 200m/drum DX 24x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK E 6470DX 48x2x0.5, Symmetrical data cable for industrial control equipment, NOMAK E 48

49 LONAK 2 x 1.3 mm² Building automation cable identification Pair stranding Cable lay up Wrapping Rip cord Outer sheath Stranded copper wires, tinned 1.3 mm2, 7x0.49 mm, Ø 1.47 mm PVC, 2.69 mm Ø 1 x white, 1 x blue 2 conductors to the pair 1 pair to the core 1 x PET foil yes PVC, grey RAL 7035, Ø 7.0 mm Nom. 7.0 mm Nom. 70 kg/km 1.7 LONAK Industrial Data 1. Operating temperature Min. Installation temperature Minimum bending radius Minimum bending radius (during pulling) Maximum pulling force C to + 70 C 5 C 10 x D 15 x D 1 N Loop DC resistance (max.) resistance (at 500 V, 1 min.) Mutual capacitance at 800 Hz (max.) Velocity factor Max. operating voltage DC Test voltage conductor/conductor 28 Ω/km MΩ*km 72 nf/km V 3.5 kv (3578) 2x1.3 mm², Building automation cable, LONAK 2 x 1.3 mm² (L432332) 49

50 LONAK Industrial Data LONAK 2x2x0.65 Building automation cable identification Stranding Cable lay up Wrapping Overall shielding Rip cord and identification thread Outer sheath Copper wire, tinned 0.34 mm2, Ø 0.65 mm PE, 1.55 mm Ø Pair 1: white, blue, Pair 2: white, orange 2 conductors to the pair 2 pairs to the core 1 x PET foil Laminated ALfoil + copper drain wire yes PVC, grey RAL 7035, Ø 7.1 mm Nom. 7.1 mm Nom. 43 kg/km Fixed indoor installations LON cabling Building automation Mechanical Properties Operating temperature Min. Installation temperature Minimum bending radius Minimum bending radius (during pulling) Maximum pulling force Loop DC resistance (max.) resistance (at 500 V, 1 min.) Mutual capacitance at 800 Hz (max.) Velocity factor Resistance unbalance (max.) Capacitance unbalance (max.) Max. operating voltage DC Test voltage conductor/conductor Test voltage conductor/screen C to + 70 C 5 C 10 x D 15 x D 65 N 106 Ω/km MΩ*km 49 nf/km % 1600 pf/m 75 V 2 kv DC, 1 min 2 kv DC, 1 min CS2638 2x2x0.65 mm, Building automation cable, LONAK 2x2x0.65 L

51 LONAK 2x2x0.8 Building automation cable Construction 1.7 LONAK Industrial Data 1. identification Stranding Cable lay up Wrapping Overall shielding Rip cord and identification thread Outer sheath Copper wire, tinned 0.5 mm2, Ø 0.80 mm PVC, 1.6 mm Ø Pair 1: whiteblue, blue, Pair 2: whiteorange, orange 4 conductors to the quad 1 quad to the core 1 x PET foil Laminated ALfoil + copper drain wire yes PVC, grey RAL 7035, Ø 7.0 mm Nom. 7.0 mm Nom. 54 kg/km Mechanical Properties Operating temperature Min. Installation temperature Minimum bending radius Minimum bending radius (during pulling) Maximum pulling force Electrical Properties at 20 C Loop DC resistance (max.) resistance (at 500 V, 1 min.) Mutual capacitance at 800 Hz (max.) Velocity factor Max. operating voltage DC Test voltage conductor/conductor Test voltage conductor/screen C up to + 70 C 5 C 10 x D 15 x D N 73 Ω/km MΩ*km 98 nf/km V 2.25 kv DC, 1 min. 1.5 kv DC, 1 min. Fixed indoor installations LON cabling Building automation 3580 CS L x2x0.8 mm, Building automation cable, LONAK 2x2x0.8 51

52 LONAK Industrial Data Fixed indoor installations LON cabling Building automation LONAK 2 x 1.3 mm² ARM Building automation cable Construction identification Pair stranding Cable lay up Wrapping Rip cord and identification thread Inner sheath Wrapping Armouring Outer sheath Mechanical Properties Operating temperature Min. Installation temperature Minimum bending radius Minimum bending radius (during pulling) Maximum pulling force Stranded copper wires, tinned 1.3 mm2, 7x0.49 mm, Ø 1.47 mm PE, 2.69 mm Ø 1 x white, 1 x blue 2 conductors to the pair 1 pair to the core 1 x PET foil yes PVC, grey RAL 7035, Ø 7.0 mm 1 x PET foil 2 x galvanized steel tape 15x0.20 mm PE, black RAL 05, Ø 10.3 mm Nom mm Nom. 172 kg/km C up to + 70 C 5 C 10 x D 15 x D 1 N Electrical Properties at 20 C Loop DC resistance (max.) resistance (at 500 V, 1 min.) Mutual capacitance at 800 Hz (max.) Velocity factor Max. operating voltage DC Test voltage conductor/conductor 28 Ω/km MΩ*km 72 nf/km V 3.5 kv Ordering Information (3581) 2x1.3 mm², Building automation cable, LONAK 2 x 1.3 mm² ARM (L432494) 52

53 UMNWV Steel Wire Armoured ALPA Unitube Optical Cable Features Loose Tube: Cable core: Moisture Barrier: 1st Inner sheath: 2nd Inner Sheath: Armour: Outer sheath: No.of Fibres Loose Tube Ø 1st Inner sheath thickness 2nd Inner sheath thickness Dia over 2nd inner sheath Armour SWA thickness Dia over SWA armour Sheath thickness Cable Diameter Cable 1 24 Please refer to our General Installation, Safety & Handling recommendations before handling. 1.8 Outside Plant Industrial FO Cables 1. Test Standard Specified value Acceptance Criteria* Max. Tension(long term) 4000N Δα Max. Tension(short term) 4800N Δα Crush Δα Impact Δα Repeated bending Δα Cable bend Δα Water Penetration UV resistancy Heat & Oil resistancy Flame retardancy Single cable test Bundle cable test Resistance to nitric acid Resistance to hydrocarbon mixture * values for singlemode fibres, all optical measurements performed at 1550 nm Min. bending radius Temperature range UMNWV UMNWVUMNWV UMNWV UMNWV008M1 UMNWV UMNWV SERIES UMNWV CORE QUANTITY XXX FIBRE TYPE XX CORES CORES CORES CORES CORES CORES SM SINGLEMODE, G652D, 9um (yellow sheath) M1 OM1, 62.5um (orange sheath) M2 OM2, 50um (orange sheath) M3 OM3, 50um (aqua sheath) M4 OM4, 50um (aqua sheath) 53

54 Outside Plant Industrial FO Cables This cable is especially designed for harsh environments. The steel wire armour and the PVC outer sheath make the cable suitable for installation under and above ground. Swellable water blocking tape over the stranding and water tightness compound within loose tube provide resilient and robust moisture protection to the fibre. Having an outer PVC sheath over an inner lead sheath make this cable relatively flexible, flame retardant, and resistant to chemical solvent, oil, and abrasion. IEC , IEC SMLVLVWV Loose Tube Fibre Optic Cable Dry Core Lead Sheath Steel Wire Armour FRPVC Sheaths Features Central Strength Member (CSM): Loose Tube: Filler Elements: Stranding: Cable core: 1st Inner sheath: Lead sheath: 2nd Inner sheath: Armour: Outer sheath: Configuration No.of Fibres No: of tubes/ fillers Loose Tube / Filler Ø [mm] CSM Ø [mm] 1st Inner sheath [mm] Lead Sheath [mm] Lead [kg/km] 2nd Inner sheath [mm] Armor wire [mm] Outer Sheath [mm] Cable Diameter [mm] Cable [kg/km] Pulling Force Da 0.05 db [kn] MADE IN EU 96 Main Mechanical and Environmental Characteristics Test Max. Tension(long term) Crush Impact Repeated bending Cable bend Water Penetration Flame retardancy Single cable test Bundle cable test All optical measurements at 1550 nm. Standard Specified value Acceptance Criteria* Δα Δα Δα Δα Δα Temperature Range Temperature range Ordering Information SMLVLVWV SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters SMLVLVWV to denote that it is a SMLVLVWV SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type. Example of a SMLVLVWV SERIES FO Cable part number: SMLVLVWV012M1 The above example describes an OM1 (62.5um, Orange Sheath) SMLVLVWV SERIES FO Cable, with 12 cores. SMLVLVWV SERIES SMLVLVWV CORE QUANTITY XXX CORES CORES CORES CORES CORES FIBRE TYPE XX SM SINGLEMODE, G652D, 9um (yellow sheath) M1 OM1, 62.5um (orange sheath) M2 OM2, 50um (orange sheath) M3 OM3, 50um (aqua sheath) M4 OM4, 50um (aqua sheath) 54

55 LMNWG Steel Wire Armoured ALPA Optical Cable Features Central Strength Member (CSM): Loose Tube: Filler Elements: Stranding: Cable core: Aramid yarns: Moisture Barrier: 1st Inner sheath: 2nd Inner Sheath: Armour: Outer sheath: Technical Data No.of Fibres Number of tubes / fillers Number of fibres per tube Loose Tube Ø Central Strength member 1st Inner sheath thickness 2nd Inner sheath thickness Dia over 2nd inner sheath Steel Wire thickness Sheath thickness Cable Diameter Cable Please refer to our General Installation, Safety & Handling recommendations before handling. 1.8 Outside Plant Industrial FO Cables The cable is especially designed for harsh (nylon) withstands aggressive constituents and fluids that might occur on (petro)chemical plants. suitable for installation under and above ground. 1. Test Max. Tension Crush Impact Repeated bending Cable bend Torsion Water Penetration UV resistancy Halogen free Heat & Oil resistancy Flame retardancy Single cable test Bundle cable test Resistance to nitric acid Resistance to hydrocarbon mixture Standard Specified value Acceptance Criteria* Δα Δα Δα Δα Δα * values for singlemode fibres, all optical measurements performed at 1550 nm Min. bending radius Temperature range LMNWG The part number always starts with the letters LMNWG to denote that it is a LMNWG LMNWG LMNWG024M1 LMNWG LMNWG SERIES LMNWG CORE QUANTITY XXX CORES CORES CORES CORES CORES FIBRE TYPE XX SM SINGLEMODE, G652D, 9um (yellow sheath) M1 OM1, 62.5um (orange sheath) M2 OM2, 50um (orange sheath) M3 OM3, 50um (aqua sheath) M4 OM4, 50um (aqua sheath) 55

56 Outside Plant Industrial FO Cables TF20 Dry Core, Aluminium Tape Screened, Steel Wire Armoured, LSZH Double Sheathed, Fibre Optic Cable This cable is especially designed for harsh environments. The steel wire armour and the flame retardant zero halogen outer sheath make the cable suitable for installation under and above ground. Its UV stabilized low smoke zero halogen double sheath makes this cable flame retardant and relatively resistant to UV, oil, water and nuclear radiation. This dry core cable employs dualside copolymer coated aluminum tape and water tightness compound within loose tube to provide resilient and robust moisture protection to the fibre. IEC , IEC , IEC , IEC /2 Features Central strength member (CSM): Tube: Stranding: Longitudinal Water Tightness: Peripheral reinforcement: Moisture barrier: Inner sheath: Armour : Outer Sheath: Technical Data No.of Fibres Design Loose Tube / Filler Ø CSM/Covered Sheath thicknessnom Cable Diameter Cable Max installation tension Min. bending radius Temperature range C Please refer to our General Installation, Safety & Handling recommendations before handling. MADE IN EU Main Characteristics Test Maximum Tension at installation (short term) Standard Value Sanction* Δα Tension opération max Δα Crush Δα Impact Δα Repeated bending Δα Cable bend Δα Temperature range Δα Water Penetration * values for singlemode fibres, all optical measurements performed at 1550 nm Ordering Information TF20 SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters TF20 to denote that it is a TF20 SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type. Example of a TF20 SERIES FO Cable part number: TF20048M1 The above example describes an OM1 (62.5um, Orange Sheath) TF20 SERIES FO Cable, with 48 cores. TF20 SERIES TF20 CORE QUANTITY XXX CORES CORES CORES CORES FIBRE TYPE XX SM SINGLEMODE, G652D, 9um (yellow sheath) M1 OM1, 62.5um (orange sheath) M2 OM2, 50um (orange sheath) M3 OM3, 50um (aqua sheath) M4 OM4, 50um (aqua sheath) 56

57 LTFMSMNWM Heavy Armoured Cable Nylon + LSZH Sheath, Chemical/Corrosive Resistant Features Central Strength Member (CSM): Tube: Stranding: Core Wrapping: Inner Sheath: Inner Armour: Middle Sheath: Nylon sheath: Outer Armour: Outer Sheath: Technical Data No.of Fibres Number of fibres per tube Loose Tube Ø CSM/sheath diameter Inner sheath thickness Middle sheath thickness Nylon sheath thickness Galvanized steel wire Outer sheath thickness Cable Diameter Cable Max installation tension Min. bending radius Temperature range 2,4,8 6,12 24,36, Please refer to our General Installation, Safety & Handling recommendations before handling. 1.8 Outside Plant Industrial FO Cables This cable is especially designed for harsh environments. The double armour combination of corrugated steel tape and galvanized steel provide superior crush protection to the fibers. The nylon inner sheath provides antitermite protection and the galvanized steel wire outer sheath provides antirodent protection. Water tightness compound within loose tube reinforced by polyster tape and jelly protects the fibers against chemical, corrosion and moisture. IEC , IEC , IEC , IEC /2 1. Main Characteristics Test Standard Specified value Sanction* Max. installation tension Δα Crush Δα Impact Δα Temperature Cycling Δα Water Penetration * Values for singlemode fibres, all optical measurements performed at 1550 nm * Values for multimode fibres, all optical measurements performed at 10 nm Ordering Information UC FIBRE LTFMSMNWM SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters LTFMSMNWM to denote that it is a UC FIBRE LTFMSMNWM SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type. Example of a UCFIBRE LTFMSMNWM SERIES FO Cable part number: LTFMSMNWM008M1 The above example describes an OM1 (62.5um, Orange Sheath) UC FIBRE LTFMSMNWM SERIES FO Cable, with 8 cores. LTFMSMNWM SERIES LTFMSMNWM CORE QUANTITY XXX FIBRE TYPE XX CORES CORES CORES CORES CORES CORES CORES CORES CORES CORES SM SINGLEMODE, G652D, 9um (yellow sheath) M1 OM1, 62.5um (orange sheath) M2 OM2, 50um (orange sheath) M3 OM3, 50um (aqua sheath) M4 OM4, 50um (aqua sheath) 57

58 2. Coaxial Cables 2. Coaxial Cables 58

59 Coaxial Cables Coaxial Cables RG58/U 95% Tin Copper Braid LSZH RG59/U 65% Aluminium Braid PVC RG59/U 95% Bare Copper Braid LSZH RG58/U 95% Bare Copper Braid LSZH SWB RG6/U 95% Aluminium Braid PVC RG6/U 95% Tin Copper Braid LSZH RG6/U 95% Tin Copper Braid LSZH SWB RG11/U 95% Tin Copper Braid LSZH RG12/U 95% Bare Copper Braid LSZH GSW RG213/U 95% Bare Copper Braid LSZH RG214/U % Silver Copper Braid LSZH RG214/U % Silver Copper Braid LSZH SWB RG215/U 95% Bare Copper Braid LSZH RG215/U 95% Bare Copper Braid LSZH SWB

60 2. Coaxial Cables Outer Jacket Dielectric 1st Outer Inner PREMIUM RG58/U 95% Tin Copper Braid LSZH Coaxial Cable, 50 Ohm Construction Material Detail inches mm Inner Dielectric 1 st Outer Outer Jacket Sheath Marking Stranded Tin Copper Solid Polyethylene 95% Tin Copper Braid Low Smoke Zero Halogen 19/ Mechanical Specification Minimum Bend Radius 19/ DRAKA RG58C/U LSZH 50 OHM COAXIAL CABLE + meter marking + batch number inches mm Any device that functions as a transmitter or transceiver tends to use 50 Ohm Coaxial Cable. Widely used for radiocommunication and amateur radio, thin Ethernet (10BASE2) electronics. Suitable for high EMI environments. IEC , IEC , IEC /2, MILC17 Optional Electrical Specification at 20 C Impedance, Ω Velocity of Propagation, % Capacitance, Nominal DC Resistance Inner Ordering Information.48 pf/ft Ω / kft ± pf/m Ω / km 38 RG8156 RG58/U 95% Tin Copper Braid PVC 500m/drum RG8256 RG58/U 95% Tin Copper Braid LSZH 500m/drum RG8356 RG58/U 95% Tin Copper Braid FRNC 500m/drum Coaxial Cable,75 Ohm Outer Jacket 2nd Outer $/&! Dielectric 1st Outer Inner Construction Material Detail inches mm Inner Dielectric 1 st Outer nd Outer Outer Jacket Sheath Marking Mechanical Specification Copper Covered Steel Gas Injected Foam High Density Polyethylene % Tape Bonded Aluminium FoilPolyster Tape Aluminium 65% Aluminium Braid Black PVC RG59 75 Ohm coaxial is used to carry baseband video in closedcircuit television. expect to get a distance of about 225m 5m. Optional Minimum Bend Radius Electrical Specification at 20 C inches mm Impedance, Ω Velocity of Propagation, % 75 ± 3 83 Capacitance, Nominal 16.2 pf/ft pf/m DC Resistance Ω / kft Ω / km Inner Outer Ordering Information RG9174 RG59/U 65% Aluminium Braid PVC 500m/drum RG9274 RG59/U 65% Aluminium Braid LSZH 500m/drum RG9374 RG59/U 65% Aluminium Braid FRNC 500m/drum 60

61 RG59/U 95% Bare Copper Braid LSZH Coaxial Cable, 75 Ohm Construction Coaxial Cables PREMIUM 2. Material Detail inches mm Inner Dielectric 1 st Outer Outer Jacket Copper Covered Steel Solid Polyethylene 95% Bare Copper Braid Low Smoke Zero Halogen Sheath Marking DRAKA RG58C/U LSZH 50 OHM COAXIAL CABLE + meter marking + batch number Outer Jacket Dielectric 1st Outer Inner Minimum Bend Radius inches mm C Impedance, Ω Velocity of Propagation, % 75 ± 3 66 Capacitance, Nominal pf/ft 67 pf/m DC Resistance Ω / kft Ω / km Inner Outer RG9171 RG59/U 95% Bare Copper Braid PVC 500m/drum RG9271 RG59/U 95% Bare Copper Braid LSZH 500m/drum RG9371 RG59/U 95% Bare Copper Braid FRNC 500m/drum Optional RG59/U 95% Bare Copper Braid LSZH Coaxial Cable, 75 Ohm, SWB PREMIUM Construction Material Detail inches mm Inner Dielectric 1 st Outer Inner Jacket Armour Outer Jacket Sheath Markin Copper Covered Steel Solid Polyethylene 95% Bare Copper Braid Low Smoke Zero Halogen 80% Galvanized Steel Wire Low Smoke Zero Halogen Outer Jacket Armour Dielectric Inner Jacket 1st Outer Inner Minimum Bend Radius C Impedance, Ω Velocity of Propagation, % 75 ± 3 66 Capacitance, Nominal pf/ft 67 pf/m DC Resistance Ω / kft Ω / km Inner Outer inches mm RG9171B RG59/U 95% Bare Copper Braid PVC SWB 500m/drum RG9271B RG59/U 95% Bare Copper Braid LSZH SWB 500m/drum RG9371B RG59/U 95% Bare Copper Braid FRNC SWB 500m/drum Optional 61

62 2. Coaxial Cables Coaxial Cable, 75 Ohm Construction Outer Jacket 2nd Outer $/&! Dielectric 1st Outer Inner Material Detail inches mm Inner Dielectric 1 st Outer nd Outer Jacket Bare Copper Covered Steel GasInjected Foamed Polyethylene Bonded Aluminum FoilPolyester TapeAluminum Foil, % Coverage Aluminium Braid % Coverage Black PVC Optional PREMIUM Minimum Bend Radius (Install) C RG6/U 95% Tin Copper Braid LSZH Coaxial Cable, 75 Ohm inches mm Characteristic Impedance Ω Velocity of Propagation % 75 ± 3 Nominal 83 Capacitance, Nominal 16.2 pf/ft 53.2 pf/m DC Resistance Ω / kft Ω / km Inner Outer RG6174 RG6/U % Aluminium Braid PVC 500m/drum RG6274 RG6/U % Aluminium Braid LSZH 500m/drum RG6374 RG6/U % Aluminium Braid FRNC 500m/drum Outer Jacket 2nd Outer $/&! Dielectric 1st Outer Inner Construction Material Detail inches mm Inner Dielectric 1 st Outer 2 nd Outer Jacket Sheath Marking Bare Copper Foamed Polyethylene Aluminum/Mylar Foil, % 95% Tin Plated Copper Braid Low Smoke Zero Halogen Minimum Bend Radius inches mm Optional C Impedance, Ω Velocity of Propagation, % 75 ± 3 85 Capacitance, Nominal 16.2 pf/ft 53.2 pf/m DC Resistance Ω / kft Ω / km Inner Outer RG6178 RG6/U 95% Tin Copper Braid PVC 500m/drum RG6278 RG6/U 95% Tin Copper Braid LSZH 500m/drum RG6378 RG6/U 95% Tin Copper Braid FRNC 500m/drum 62

63 Coaxial Cable, 75 Ohm, SWB Construction Coaxial Cables PREMIUM 2. Material Detail inches mm Inner Dielectric 1 st Outer 2 nd Outer Inner Jacket Armour Outer Jacket Sheath Marking Bare Copper Foamed Polyethylene Aluminum/Mylar Foil, % 95% Tin Plated Copper Braid Low Smoke Zero Halogen 80% Galvanized Steel Wire Low Smoke Zero Halogen Outer Jacket Armour Inner Jacket 1st Outer Dielectric 2nd Outer Inner Minimum Bend Radius C Impedance, Ω Velocity of Propagation, % 75 ± 3 85 Capacitance, Nominal 16.2 pf/ft 53.2 pf/m DC Resistance Ω / kft Ω / km Inner Outer inches mm RG6178B RG6/U 95% Tin Copper Braid PVC SWB 500m/drum RG6278B RG6/U 95% Tin Copper Braid LSZH SWB 500m/drum RG6378B RG6/U 95% Tin Copper Braid FRNC SWB 500m/drum Optional RG11/U 95% Bare Copper Braid LSZH Coaxial Cable, 75 Ohm PREMIUM Construction Material Detail inches mm Inner Dielectric 1 st Outer Outer Jacket Sheath Marking Bare Copper Foamed Polyethylene 95% Bare Copper Braid Low Smoke Zero Halogen Outer Jacket Dielectric 1st Outer Inner Minimum Bend Radius inches mm C Impedance, Ω Velocity of Propagation, % 75 ± 3 85 Capacitance, Nominal 16.2 pf/ft 53.2 pf/m DC Resistance Ω / kft Ω / km Inner RG1171 RG11/U 95% Bare Copper Braid PVC 500m/drum RG1271 RG11/U 95% Bare Copper Braid LSZH 500m/drum RG1371 RG11/U 95% Bare Copper Braid FRNC 500m/drum Optional 63

64 2. Coaxial Cables Outer Jacket Armour Inner Jacket 1st Outer PREMIUM Dielectric Inner Coaxial Cable, 75 Ohm, Armoured Material Detail inches mm Inner Dielectric 1 st Outer Inner Jacket Armour Outer Jacket Sheath Marking Bare Copper Foamed Polyethylene 95% Bare Copper Braid Low Smoke Zero Halogen 80% Galvanized Steel Wire Low Smoke Zero Halogen Optional PREMIUM Minimum Bend Radius Coaxial Cable, 50 Ohm inches mm Impedance, Ω Velocity of Propagation, % 75 ± 3 85 Capacitance, Nominal 16.2 pf/ft 53.2 pf/m DC Resistance Ω / kft Ω / km Inner RG2171W RG12/U 95% Copper Braid PVC GSW 500m/drum RG2271W RG12/U 95% Copper Braid LSZH GSW 500m/drum RG2371W RG12/U 95% Copper Braid FRNC GSW 500m/drum Outer Jacket Dielectric 1st Outer Inner Material Detail inches mm Inner Dielectric 1 st Outer Outer Jacket Sheath Marking Stranded Bare Copper Solid Polyethylene 95% Bare Copper Braid PVC 7/ / Minimum Bend Radius inches mm Optional Impedance, Ω Velocity of Propagation, % Capacitance, Nominal DC Resistance Inner 50 ± pf/ft.0 pf/m Ω / kft Ω / km RG3151 RG213/U 95% Copper Braid PVC 500m/drum RG3251 RG213/U 95% Copper Braid LSZH 500m/drum RG3351 RG213/U 95% Copper Braid FRNC 500m/drum 64

65 Coaxial Cable, 50 Ohm Coaxial Cables PREMIUM 2. Material Inner conductor 1st braid 2nd braid Jacket Minimum Bend Radius Temperature Corrosivity of fire gases Smoke density Detail Stranded copper wires, silver plated 7 x 0.75, diameter 2.25 ± 0.10 mm PE, diameter 7.25 ± 0.10 mm Silver plated, 94% coverage Silver plated, % coverage Low Smoke Zero Halogen without load with load during operation during installation DC Resistance Inner 1st Braid 2nd Braid Mutual Capacitance, Nominal Characteristic Impedance, Ω Velocity Ratio, % Maximum Operating Frequency Operating Voltage Test Voltage Coaxial Cable, 50 Ohm, SWB 5 x outer diameter 10 x outer diameter 45 C to + 85 C 15 C to + 55 C acc. to IEC acc. to IEC and 2.5 pf/ft GHz 3.7 kv rms Inner/Outer conductor Ω / kft mm 108 mm Any device that functions as a transmitter 50 ± kv rms RG4157 RG214/U % Silver Copper Braid PVC 500m/drum RG4257 RG214/U % Silver Copper Braid LSZH 500m/drum RG4357 RG214/U % Silver Copper Braid FRNC 500m/drum Outer Jacket 2nd Outer Dielectric 1st Outer Optional PREMIUM Inner Material Inner Dielectric 1st Outer 2nd Outer Inner Jacket Armour Outer Jacket Minimum Bend Radius Detail Silver Plated Copper 7 x 0.75mm Solid Polyethylene 94% Silver Plated Copper Braid % Silver Plated Copper Braid Low Smoke Zero Halogen Steel Wire Braid Low Smoke Zero Halogen DC Resistance Inner 1st Braid 2nd Braid Mutual Capacitance, Nominal Characteristic Impedance, Ω Velocity Ratio, % Maximum Operating Frequency Operating Voltage Test Voltage pf/m GHz 3.7 kv rms Inner/Outer conductor inches Ω / km ± kv rms mm inches mm RG4157B RG214/U % Silver Copper Braid PVC SWB 500m/drum RG4257B RG214/U % Silver Copper Braid LSZH SWB 500m/drum All RG4357B Rights Reserved 2015 I RG214/U Property of % Prysmian Silver Group Copper Braid FRNC SWB 500m/drum Outer Jacket Armour Inner Jacket 2nd Outer 1st Outer Any device that functions as a transmitter or Dielectric Optional Inner 65

66 2. Coaxial Cables Outer Jacket Dielectric 1st Outer Inner PREMIUM Coaxial Cable, 50 Ohm Material Detail inches mm Inner Dielectric 1 st Outer Outer Jacket Bare Copper Solid Polyethylene 95% Bare Copper Braid LSZH 7/ / Optional Outer Jacket Armour Dielectric Inner Jacket 1st Outer Inner Optional PREMIUM Minimum Bend Radius 0 DC Resistance Inner Capacitance, Nominal Characteristic Impedance, Ω Velocity of Propagation, % Coaxial Cable, 50 Ohm, SWB Material Detail inches mm Inner Dielectric 1 st Outer Inner Jacket Armour Outer Jacket Sheath Marking Bare Copper Solid Polyethylene 95% Bare Copper Braid Low Smoke Zero Halogen Steel Wire Braid Low Smoke Zero Halogen 7/ / Minimum Bend Radius DC Resistance Inner Capacitance, Nominal Characteristic Impedance, Ω inches mm Ω / km Ω / km pf/m pf/m 50 ± 3 inches mm Ω / km Ω / km pf/m pf/m 50 ± 3 66 RG5151 RG215/U 95% Bare Copper Braid PVC 500m/drum RG5251 RG215/U 95% Bare Copper Braid LSZH 500m/drum RG5351 RG215/U 95% Bare Copper Braid FRNC 500m/drum RG5151B RG215/U 95% Bare Copper Braid PVC SWB 500m/drum RG5251B RG215/U 95% Bare Copper Braid LSZH SWB 500m/drum RG5351B RG215/U 95% Bare Copper Braid FRNC SWB 500m/drum 66

67 Coaxial Cables 2. TM rd From the World s Largest Cable Manufacturer Used extensively in: Data Centres Enterprise Buildings Industrial Airports Institutions ASIA HQ No. 20 Jurong Port Road, Jurong Town Singapore mms.asia@prysmiangroup.com Tel Fax

68 3. Building Management Systems 3. Building Management Systems 68

69 Building Management Systems EIA485 EIA & 24 AWG LSZH EIA & 24 AWG SWB LSZH 3.2 Screened Control Cable UL 2464 Overall Screen 1624AWG PVC UL 2464 Overall Screen 1624AWG SWB LSZH UL 2919 INDIVPAIR Screen 1824AWG LSZH 3.3 Max FOH Max FOH Flexible PAGA & Control Cable 3.4 Firetuf IE Firetuf DATA 1P, 2P or 4P LSZHFR Firetuf OFCUTNM Fire Resistant Universal Central Tube Cable Firetuf OFCUTCST Fire Resistant Armoured Central Tube Cable 1296 Core Firetuf I10S Fire Resistant Fibre Optic Cable, LSZH 3.5 Fibre Optic Cables UC FIBRE MT SERIES 224 Cores, Indoor UCFIBRE MT SERIES 36,48,96 Cores, Indoor UCFIBRE MTC SERIES, 36 & 48 Cores, Compact UC FIBRE MB SERIES 3.6 MultiPair Category Cables Category 3 UTP 25/50/x2x0.5 Multipair Category 5e 25/50/x2x0.5 Multipair

70 3. Building Management Systems 3.1 EIA485 EIA & 24AWG LSZH Serial Data Communication Cable Sheath AlMylar Pair Drain wire Filler Braid shield Colour 1st screen Drain wire Braid Shield Braid Shield Coverage Sheath Sheath colour Stranded Tinned Copper HDPE Pair 1: 1 x white, 1 x blue Pair 2: 1 x white, 1 x orange Pair 3: 1 x white, 1 x black Pair 4: 1 x green 1 x ALMylar Wrap, overlapping >= 25 % Stranded Tinned Copper Tinned copper 85% LSZH Black Optional AWG / Pair 0 mm 0 mm Drain wire 0 mm Braid shield Sheath 0 mm 22 / 1P 22 / 2P 22 / 3P 22 / 4P 24 / 1P 24 / 2P 24 / 3P 24 / 4P ± ± * * *6* 16*10* 16*12* 16*12* 16*5* 16*11* 16*9* 16*11* 0.12mm 0.12mm 0.12mm 0.12mm 0.12mm 0.12mm 0.12mm 0.12mm AWG / Pair resistance Rated Voltage 22 / 1P 22 / 2P 22 / 3P 22 / 4P 24 / 1P 24 / 2P 24 / 3P 24 / 4P 58 Ω/km 89 Ω/km 0 V AWG / Pair Rated temperature 22 / 1P 22 / 2P 22 / 3P 22 / 4P 24 / 1P 24 / 2P 24 / 3P 24 / 4P +80 C 48422L EIA 485 PAIRING AWG SHEATH 48 X XX X 1 1 Pair 2 2 Pair 4 4 Pair AWG AWG (nil) PVC L LSZH P PE 70

71 EIA485 22&24 AWG SWB LSZH Serial Data Communication Cable, Armoured Building Management Systems 3.1 EIA Colour 1st screen Drain wire Braid Shield Inner Sheath Braid Armour Outer Sheath AWG / Pair 0 mm 0 mm Drain wire 0 mm Braid shield Inner Sheath 0 mm Braid Armour 0 mm Outer Sheath 0 mm Stranded Tinned Copper HDPE Pair 1: 1 x white, 1 x blue Pair 2: 1 x white, 1 x orange Pair 3: 1 x white, 1 x black Pair 4: 1 x green 1 x ALMylar Wrap, overlapping >= 25 % Stranded Tinned Copper Tinned copper ; coverage 85% LSZH Galvanized Steel Wire Braid ; >85% LSZH 22 / 1P 22 / 2P 22 / 3P 22 / 4P 24 / 1P 24 / 2P 24 / 3P 24 / 4P ± ± * * *6* 16*10* 16*12* 16*12* 16*5* 16*11* 16*9* 16*11* 0.12mm 0.12mm 0.12mm 0.12mm 0.12mm 0.12mm 0.12mm 0.12mm Optional Outer Sheath AlMylar Pair Drain wire Filler Inner Sheath Steel Wire Braid AWG / Pair resistance Rated Voltage 22 / 1P 22 / 2P 22 / 3P 22 / 4P 24 / 1P 24 / 2P 24 / 3P 24 / 4P 58 Ω/km 89 Ω/km 0 V AWG / Pair Rated temperature 22 / 1P 22 / 2P 22 / 3P 22 / 4P 24 / 1P 24 / 2P 24 / 3P 24 / 4P +80 C 48422LB EIA 485 PAIRING AWG SHEATH OUTER JACKET 48 X XX X X 1 1 Pair 2 2 Pair 4 4 Pair AWG AWG (nil) PVC L LSZH P PE B SWB 71

72 3. Building Management Systems 3.2 Screened Control Cable UL 2464 Overall Screen 1624AWG PVC Overall Screened Data Control Cable Technical Details Twisted Pair Jacket AlMylar Drain Wire Operating Voltage Overall diameter (mm) Dia. (±0.08mm) Twist(Direction) Drain wire(construction,mm) Assembly AlMylar Wrap(overlapping,%) Jacket colour Rated Temperature Fully annealed stranded tinned copper per ASTM B33 0V Premium grade SRPVC nominal 1.1 S 7/0.254mm Stranded Tinned Copper Pairs + Drain wire 25% PVC White/Brown, Green/Yellow, Gray/Pink, Blue/Red +80 C For installation requiring flexible connector cable to fulfill measuring, controls & command applications ie Computer Interconnection, Data Transmission, Control Circuits, Industrial Equipment Control, suitable for EIA RS232 applications. Optional LSZH Cable Dimension Size 16 AWG 18 AWG 20 AWG 22 AWG 24 AWG DC 20 C (Ω/km) <= <= <= <=.0 <= <= <= <= <= 36.0 <= 36.0 <= 36.0 <= 36.0 <= 56.0 <= 56.0 <= 56.0 <= 56.0 <= <= <= <= No of Pairs OD (mm) ± 5% 1 Pair 2 Pairs 3 Pairs 4 Pairs 1 Pair 2 Pairs 3 Pairs 4 Pairs 1 Pair 2 Pairs 3 Pairs 4 Pairs 1 Pair 2 Pairs 3 Pairs 4 Pairs 1 Pair 2 Pairs 3 Pairs 4 Pairs Ordering Information UL AWG part numbers are made up using the table below. The part number starts with 24 to denote that it is an UL 2464 cable. The following number shows the number of pairing and the last 2 numbers signifies the AWG. Any letter behind would describe the sheath type. Example of an UL 2464 part number 24318L The above example describes an UL 2464 cable with 3 pairing, 18 AWG. Sheath type LSZH. UL 2464 PAIRING AWG SHEATH 24 X XX X 1 1 Pair 2 2 Pair 3 3 Pair 4 4 Pair AWG AWG AWG AWG AWG (nil) PVC L LSZH 72

73 UL 2464 OVERALL SCREEN 1624AWG SWB LSZH Overall Screened Data Control Cable, Armoured Building Management Systems 3.2 Screened Control Cable 3. Technical Details Operating Voltage colour Dia. (±0.08mm) Twist(Direction) Drain wire(construction,mm) Assembly AlMylar Wrap(overlapping,%) Inner Sheath Braid Armour Outer Sheath Rated Temperature Fully annealed stranded tinned copper per ASTM B33 0V Premium grade SRPVC White/Brown, Green/Yellow, Gray/Pink, Blue/Red 1.1 S 7/0.254mm Stranded Tinned Copper Pairs + Drain wire 25% LSZH Galvanized Steel Wire Braid, >85% LSZH +80 C Twisted Pair Outer Sheath Inner Sheath AlMylar Drain Wire Steel Wire Braid Cable Dimension Size 16 AWG 18 AWG 20 AWG 22 AWG 24 AWG DC 20 C (Ω/km) <= <= <= <=.0 <= <= <= <= <= 36.0 <= 36.0 <= 36.0 <= 36.0 <= 56.0 <= 56.0 <= 56.0 <= 56.0 <= <= <= <= No of Pairs 1 Pair 2 Pairs 3 Pairs 4 Pairs 1 Pair 2 Pairs 3 Pairs 4 Pairs 1 Pair 2 Pairs 3 Pairs 4 Pairs 1 Pair 2 Pairs 3 Pairs 4 Pairs 1 Pair 2 Pairs 3 Pairs 4 Pairs Inner Sheath (mm) ± 5% Outer Sheath over Armour Braid (mm) + 5% For installation requiring flexible connector cable to fulfill measuring, controls & command applications ie Computer Interconnection, Data Transmission, Control Circuits, Industrial Equipment Control, suitable for EIA RS232 applications. Steel wire braid provides outdoor protection against harsh handling. Optional Ordering Information UL AWG SWB part numbers are made up using the table below. The part number starts with 24 to denote that it is an UL 2464 cable. The following number shows the number of pairing and the last 2 numbers signifies the AWG. The following letter describes the sheath type and the alphabet at the end shows that this is a steel wire braided cable. Example of an UL 2464 SWB part number 24220LB The above example describes an UL 2464 cable with 2 pairing, 20 AWG. Sheath type LSZH, SWB. UL 2464 PAIRING AWG SHEATH OUTER JACKET 24 X XX X X 1 1 Pair 2 2 Pair 3 3 Pair 4 4 Pair AWG AWG AWG AWG AWG (nil) PVC L LSZH B SWB 73

74 3. Building Management Systems 3.2 Screened Data Control Cable UL 2919 INDIVPAIR SCREEN 1824AWG LSZH Individual Pair Screened Control Cable Technical Details Shielded Pair AlMylar Drain wire Braid shield Sheath Operating Voltage colour 1st screen Drain wire Coverage Sheath Sheath colour Rated temperature Stranded Tinned Copper, AWG 18, diameter 16 x mm 0V HDPE Pair 1: 1 x white, 1 x Blue Pair 2 : 1 x white, 1 x orange Pair 3 : 1 x white, 1 x green Pair 4 : 1 x white, 1 x brown 1 x ALMylar Wrap, overlapping >= 25 % 7/0.254mm Stranded Tinned Copper Braid Shield coverage 85% LSZH Grey +80 C Optional: Size 18 AWG 20 AWG 22 AWG 24 AWG Diameter (mm) DC 20 C (Ω/km) <= 23.0 <= 23.0 <= 23.0 <= 36.0 <= 36.0 <= 36.0 <= 56.0 <= 56.0 <= 56.0 <= 86.0 <= 86.0 <= 86.0 No. of Pairs 1 Pair 2 Pairs 4 Pairs 1 Pair 2 Pairs 4 Pairs 1 Pair 2 Pairs 4 Pairs 1 Pair 2 Pairs 4 Pairs Diameter (MM) 2.4 ± ± ± ± 0.2 Braid Shield % 16 / 11 / / 14 / / 17 / / 10 / / 13 / / 15 / / 09 / / 13 / / 15 / / 08 / / 12 / / 14 / 0.12 OD (mm) ± 5% L UL 2919 PAIRING AWG SHEATH 29 X XX X 1 1 Pair 2 2 Pair 3 3 Pair 4 4 Pair AWG AWG AWG AWG (nil) PVC L LSZH 74

75 Building Management Systems 3. MAXFOH Flexible PAGA & Control Cable Public Address General Alarm, Data Control Cable, Fire Resistance 3.3 Max FOH Fire Characteristics 1.5mm² Core Construction Core Outer Sheath Grade A Copper specially protected by fire barrier tape to ensure circuit integrity in fire situations. Twisted pair for better signal transmission High temperature resistance PE LSZH in accordance to IEC 61034, IEC & 2. Main Characteristics Nominal overall diameter Nominal weight (completed cable) Min bending radius Max pulling tension Max conductor 20 C Min insulation 20 C Dielectric withstand test mm Kg/km mm kgf Ω/km MΩ/km kv/min 8.0 (±0.5) /1 Technical Data Size Specification reference material Max operating temperature No of Wire / Wire Diameter shape thickness Core Colour mm C mm mm mm 2C x 1.5mm2 IEC , IEC 60331, SS299 / BS 63 CWZ Plain annealed copper wire to IEC 7 / 0.53 Circular stranded Crosslinked PE, XLPE 0.5 Black & White OR Black & Red Most widely used fire resistance speaker & Audio/Motor control cables, which is highly flexible due to the unique tubing design. Draka MAXFOH flexible speaker cables meets the stringent BS 63 fire performance standards and can be used in all critical Public Address General Alarm Systems. Generally to: ISO/IEC 11801: 95, IEC 61156, EN 50173:95; EN , BS 63 Optional: 2 Ordering Information PAGA1P15 1P x 1.5mm², PAGA, LSZH 500m/drum PAGA2P15 2P x 1.5mm², PAGA, LSZH 500m/drum PAGA1P25 1P x 2.5mm², PAGA, LSZH 500m/drum PAGA1P25 1P x 2.5mm², PAGA, LSZH 500m/drum 75

76 3. Building Management Systems 3.4 Firetuf IN EU IE Firetuf DATA 1P, 2P or 4P LSZHFR IE SF/UTP 4x2xAWG22/1 cable with circuit integrity behaviour Construction Twisting Cable lay up Fire protection wrapping Screen Sheath Colour Tensile force N bare copper wire, Ø 0.65 mm (AWG 22) PE/Sil Rbr, Ø 1.7 mm 2 cores to the pair 1, 2 or 4 pairs to the core glass tape copper braid, tinned halogen free, flame retardant thermoplastic sheathing compound acc. to EN , Ø 10.5 mm red RAL 00 Nom. 6.8(1 Pair) 10.5 (4 Pair) mm Nom. 48(1 Pair) 122 (4 Pair) kg/km Bending radius without load 42 mm with load 84 mm Temperature range during operation 20 C to + 60 C during installation 0 C to + 50 C (Horizontal) connection systems to EN 50173, part of Standards Generally to: ISO/IEC 11801: 95, IEC 61156; EN 50173:95; EN IEC , IEC &2, IEC , IEC , UL 1581 VW 1, BS58391 (clause 26.2e), BS84342, BSEN 50200, BS4066 part 3, BSEN 20568, IEC , EN50399 Fire Tests BC 5839: 2002 & IEC60331 BS5839 enhanced 3 in 1 Continued Data 950 BS63 BS EN (IEC60331) passed > 2 Hours > 3 Hours > 3 Hours Electrical Properties at 20 C ± 5 C Loop resistance Resistance unbalance resistance (500 V) 1 minute Mutual capacitance Capacitance unbalance at 800 Hz (pair/ground) Characteristic impedance (at 10) MHz Nominal velocity of propagation Test voltage Transfer Impedance (DC, 1 min) core/core and core/screen at 10 MHz Electrical Data (Nominal) acc. to Cat.5 (at 20 C) SRI 110 Ω/km 2% 2000 MΩ*km Nom. 60 nf/km 1600 pf/km ( ± 15) Ω ca. 57 % 0 V 5 mω/m Certification Approved to LUL Fire resistant BS58391 (clause 26.2e); BS84342; BSEN Flame retardant BS4066 part 3; Smoke emission BSEN LULFlammability, smoke & fume 202 LUL STANDARD e4156 part 1 approved J2Y/2G(St)CH 4x2x0.65, IE SF/UTP 4x2xAWG22/1 cable with circuit integrity behaviour, 500mm/drum IE FIRETUF DATA 1P, 2P or 4P LSZHFR J2Y/2G(St)CH 1x2x0.65, IE SF/UTP 4x2xAWG22/1 cable with circuit integrity behaviour, IE FIRETUF DATA 1P, 2P or 4P LSZHFR J2Y/2G(St)CH 2x2x0.65, IE SF/UTP 4x2xAWG22/1 cable with circuit integrity behaviour, IE FIRETUF DATA 1P, 2P or 4P LSZHFR 500mm/drum 500mm/drum 76

77 Firetuf OFCUTNM Fire Resistant Universal Central Tube Cable Indoor/Outdoor nonmetallic LSHFFR sheathed optical cable with 2 24 fibers. VDE: A/IDQ(ZN)H Building Management Systems 3.4 Firetuf 3. Fire resistance tests IEC (120) Fire resistance: 120 minutes at 750 C (No fibre break) EN PH 120 Fire resistance with fire and impact 120 minutes 8 C (No fibre break) EN ANNEX E PH Fire resistance until 15 minutes of fire and impact alone, followed by 15 minutes of fire, impact and water spray at 8 C (No fibre break) BS Fire resistance until 60 minutes of fire and impact alone, followed by 60 minutes of fire, impact and water spray at 9 C (No fibre break) Flame retardant tests IEC Single vertical wire test Flame propagation test IEC = IEC 3323C Verticallymounted bunched wires and cables Halogen acid & gas tests IEC No halogens IEC No acid matters Smoke emission tests IEC No dense smoke Loose tube Ø4.0 mm jelly filled loose tube green colored with up to 2 24 fibres Fibre colour code 1 Red 13 Yellow w/mark per mm 2 Green 14 White w/mark per mm 3 Blue 15 Grey w/mark per mm 4 Yellow 16 Turquoise w/mark per mm 5 White 17 Orange w/mark per mm 6 Grey 18 Pink w/mark per mm 7 Brown 19 Yellow w/mark every 50 mm 8 Violet 20 White w/mark every 50 mm 9 Turquoise 21 Grey w/mark every 50 mm 10 Black 22 Turquoise w/mark every 50 mm 11 Orange 23 Orange w/mark every 50 mm 12 Pink 24 Pink w/mark every 50 mm Fire barrier Tape(s) Strength member Water blocked EGlass fibre elements Ripcord 1 Inner sheath 2.5 mm black LSHFFR sheath according to EN , UV stabilised Standards Property Test method Value Nominal outer diameter 12.1 mm Nominal weight 167 kg/km Maximum installation tensile strength E N (Δl/l fibre 0.5%, Δα reversible) * Compressive strength (crush) E N / mm, max 5 min (Δα reversible ) * Impact E7 No fibre break, 5 Nm, 3 impacts, r=0mm Torsion E7 5 cycles ± 1 turn Kink E10 The cables do not form a kink when a loop is drawn together to a diameter of 20xD (Cable diameter) mm Min. bending radius, unloaded E11 R = 121 mm Min. bending radius, loaded R = 240 mm Temperature range F1 Storage: C to +60 C Installation: 0 C to +50 C Operation: 25 C to +70 C. (Δα 0.05 db /km)** Water penetration F5B No water leakage after 24 hour, sample=3m, water=1m * Values for singlemode fibres, all optical measurements performed at 1550 nm, ** Values for multimode fibres, all optical measurements performed at 850 nm or 10 nm with 0.10 db as threshold (tensile and crush will not be performed for MM fibres) A/IDQ(ZN)H Indoor/ourdoor nonmetalic LSHFFR sheathed optical cable with 224 fibres 4km/drum 77

78 3. Building Management Systems 3.4 Firetuf The application of this cable is circumstances where a very high degree of fire safety is required halogen free. The typical installation environment is indoor and need very high degree of fire safety and support for critical communication. This cable is also suitable for shipboard application. proof. The primary means of installation are on cable however also be directly buried. The cable can be installed directly exposed the sun. Standards Firetuf OFCUTCST Fire Resistant Armoured Central Tube Cable Indoor/Outdoor steel tape armoured (CST) double LSHFFR sheathed optical cable with 2 24 fibres. VDE: A/IDQ(ZN)H(SR)H Fire resistance tests IEC (120) Fire resistance: 120 minutes at 750 C (No fibre break) EN PH 120 Fire resistance with fire and impact 120 minutes 8 C (No fibre break) EN ANNEX E PH Fire resistance until 15 minutes of fire and impact alone, followed by 15 minutes of fire, impact and water spray at 8 C (No fibre break) BS Fire resistance until 60 minutes of fire and impact alone, followed by 60 minutes of fire, impact and water spray at 9 C (No fibre break) Flame retardant tests IEC Single vertical wire test Flame propagation test IEC = IEC 3323C Verticallymounted bunched wires and cables Halogen acid & gas tests IEC No halogens IEC No acid matters Smoke emission tests IEC No dense smoke Construction Loose tube Ø 4.0 mm jelly filled loose tube green colored with up to 2 24 fibres Fibre colour code 1 Red 13 Yellow w/mark per mm 2 Green 14 White w/mark per mm 3 Blue 15 Grey w/mark per mm 4 Yellow 16 Turquoise w/mark per mm 5 White 17 Orange w/mark per mm 6 Grey 18 Pink w/mark per mm 7 Brown 19 Yellow w/mark every 50 mm 8 Violet 20 White w/mark every 50 mm 9 Turquoise 21 Grey w/mark every 50 mm 10 Black 22 Turquoise w/mark every 50 mm 11 Orange 23 Orange w/mark every 50 mm 12 Pink 24 Pink w/mark every 50 mm Fire barrier Tape(s) Strength member Water blocked EGlass fibre elements Ripcord 1 Inner sheath 2.5 mm black LSHFFR sheath according to EN , UV stabilised Armouring Coated and corrosion protected corrugated steel tape (CST), thickness 0.15 mm Ripcord 1 Outer sheath 1.4 mm black LSHFFR sheath according to EN , UV stabilised Physical Properties Property Test method Value Nominal outer diameter 17 mm Nominal weight 351 kg/km Maximum installation tensile strength E N (Δl/l fibre 0.5%, Δα reversible) * Compressive strength (crush) E N / mm, max 5 min (Δα reversible ) * Impact E7 10 Nm, No fibre break, 3 impacts, r=0mm, Torsion E7 5 cycles ± 1 turn Kink E10 The cables do not form a kink when a loop is drawn together to a diameter of 20xD (Cable diameter) mm Min. bending radius, unloaded E11 R = 255 mm Min. bending radius, loaded R = 340 mm Temperature range F1 Storage: 40 C to +80 C Installation: 0 C to +50 C Operation: 40 C to +70 C. (Δ α.05 db /km)** Water penetration F5B No water leakage after 24 hour, sample=3m, water=1m, * Values for singlemode fibres, all optical measurements performed at 1550 nm, ** Values for multimode fibres, all optical measurements performed at 850 nm or 10 nm with 0.10 db as threshold (tensile and crush will not be performed for MM fibres) A/IDQ(ZN)H(SR)H Indoor/ourdoor steel tape armoured (CST) double LSHFFR sheathed optical cable with 224 fibres 4km/drum 78

79 1296 Core Firetuf I10S Fire Resistant Fibre Optic Cable, LSZH Building Management Systems 3.4 Firetuf 3. Features Central strength member (CSM) : Tube: Stranding: Longitudinal Water Tightness: Fire Barriers: Armours: Sheaths: Technical Data No.of Fibres Design (Elements Fibres per Tube) Loose Tube / FillerØ CSM / sheath diameter Inner sheath thickness Outer sheath thickness Cable Diameter Cable Max installation tension Min.bending radius Temperature range Flame Retardant Fire Resistance mm mm mm mm mm kg/km N mm C 4,6,12,24 36,48,72 96 Up to 4x6 6x6, 4x12, 6x / nominal 1.0 nominal 1.0 nominal 2.0 nominal 2.0 nominal 2.0 nominal 15.3 nominal 15.3 nominal 16.8 nominal Without Tension Under Maximum Tension 10 x CableØ 20 x CableØ Installation Transport & Storage Operation 10>+60; 10>+60; 10>+60; IEC IEC , In house test up to 800 C, 2hrs. Please refer to our General Installation, Safety & Handling recommendations before handling. Standards Optional Main Characteristics Test Max. installation tension Crush (short term) Standard Value Sanction* IEC E1 00 N fibre strain 0.33%, Δα reversible IEC E3 00 N / mm Δα 0.3 db(mm), 0.1 db(sm) Temperature range IEC F1 40>+70 C Δα 0.3 db/km(mm), 0.1 db/km(sm) Water Penetration IEC F5B 40>+70 C No water leakage after 24 hour * values for singlemode fibres, all optical measurements performed at 1550 nm. * values for multimode fibres, all optical measurements performed at 10 nm I10S024M1 I10S I10S CORE QUANTITY XXX CORES CORES CORES CORES CORES FIBRE TYPE XX SM SINGEMODE, G652D, 9um M1 OM1, 62.5um M2 OM2, 50um M3 OM3, 50um M4 OM4, 50um 79

80 3. Building Management Systems 3.5 Fibre Optic Cables UC FIBRE MT SERIES 224 Cores, Indoor Tight Buffer Distribution Cable, LSZH Features Tight buffer Strength Member : Aramid yarn Outer Sheath Suitable for indoor installation requiring flame retardant, low smoke and halogen free environment Main Characteristics Overview One of the most widely used UC FIBRE Indoor cable, MT series is excellent for indoor installation that provides a safe setup against flame propagation and its flexible yet robust construction makes installation at ease. Additional Options protection. Technical Data Test Standard Value Sanction* Maximum installation load (a few hours) Short term tensile strength (some days) IEC E1 0 N (2F8F), 1200N (12F, 24F) Fibre strain 0.6%, Δα reversible IEC E1 600N Fibre strain 0.4%, Δα reversible Max operation tension IEC E1 280N (2F12F), 340N (24F) Fibre strain 0.2%, Δα 0.4 db(mm), 0.(SM) Crush (short term) IEC E3 0 N / mm Δα 0.4 db(mm), 0.(SM), no damage Temperature range IEC F1 20 > +70 C Δα 0.6 db /km(mm), 0.40dB/km(SM) No. of Fibres 2,4, Design Tight buffer Outer sheath thickness Cable Nominal Diameter Cable mm mm mm kg / km 1 6 TB 0.9 ± TB 0.9 ± TB 0.9 ± TB 0.9 ± nominal 0.75 nominal 0.75 nominal 0.9 nominal 4.8 nominal 5.4 nominal 6.2 nominal 8.8 nominal Min. bending radius mm Without Tension 10 CableØ Under Maximum Tension 20 CableØ Temperature range C Installation 10 > +60; Transport. & Storage 40 > +70 ; Operation 20 > +70 Flame Retardant IEC Ordering Information UC FIBRE MT SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters MT to denote that it is a UC FIBRE Example of a UC FIBRE MT SERIES FO Cable part number: MT008M1 FIBRE MT SERIES FO Cable, with 8 cores. MT SERIES MT CORE QUANTITY XXX CORES CORES CORES CORES CORES FIBRE TYPE XX SM SINGEMODE, G652D, 9um (yellow sheath) M1 OM1, 62.5um (orange sheath) M2 OM2, 50um (orange sheath) M3 OM3, 50um (aqua sheath) M4 OM4, 50um (aqua sheath) 80

81 Building Management Systems 3. UCFIBRE MT SERIES 36,48,96 Cores, Indoor Tight Buffer Distribution Cable, LSZH 3.5 Fibre Optic Cables Features Each fibre is coated to 0.9mm with LSZH. Aramid yarn within each subunit LSZH material FRP with upcoating Polyester tape LSZH compliant to IEC 61034, IEC &2, IEC & Test Standard Value IEC E1 IEC E N (36F, 48F), 6600N (96F) 2800 N (36F, 48F), 4400N (96F) IEC E N (36F, 48F), 2200N (96F) Fibre strain 0.6%, Δα reversible Fibre strain 0.4%, Δα reversible Fibre strain 0.2%, Δα 0.4 db(mm), 0.(SM) IEC E3 0 N / mm Δα 0.4 db(mm), 0.(SM), no damage IEC F1 20 > +70 C Δα 0.6 db /km(mm), 0.40dB/km(SM) One of the most widely used UC FIBRE indoor installation that provides a safe setup against flame propagation and makes installation at ease. Te hn al Data Design Tight buffer mm mm mm mm mm kg/km mm C 6 6 TB 0.9 ± TB 0.9 ± TB 0.9 ± ± ± ± nominal 0.65 nominal 0.65 nominal 1.4 nominal 1.4 nominal 1.5 nominal 17.7 ± ± ± Installation 10 > +60; Without Tension 10 CableØ Transport. & Storage 40 > +70 ; Under Maximum Tension 20 CableØ Operation 20 > +70 Please refer to our General Installation, Safety & Handling recommendations before handling. Ordering Information IEC UC FIBRE MT SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters MT to denote that it is a UC FIBRE Example of a UC FIBRE MT SERIES FO Cable part number: MT036M1 FIBRE QUANTITY XXX XX 81

82 3. Building Management Systems 3.5 Fibre Optic Cables UC FIBRE MTC SERIES, 36 & 48 Cores, COMPACT Indoor Tight Buffer Distribution Cable, LSZH Features 36 cores Tight buffer: Strength Member: Core Wrapping: Outer Sheath: 48 cores Main Characteristics Test Value Short term tensile Δα Δα Max operation tension Δα Crush (short term) Δα Temperature range Δα Technical Data Design Tight buffer Size Cable Cable Temperature range Ordering Information UC FIBRE MTC SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters MTC to denote that it is a UC FIBRE MTC SERIES FO Cable. This is followed by 3 numbers which symbolises the Example of a UC FIBRE MTC SERIES FO Cable part number: MTC048M4 FIBRE MTC SERIES FO Cable, with 48 cores. MTC SERIES MTC CORE QUANTITY XXX CORES CORES FIBRE TYPE XX SM SINGEMODE, G652D, 9um (yellow sheath) M1 OM1, 62.5um (orange sheath) M2 OM2, 50um (orange sheath) M3 OM3, 50um (aqua sheath) M4 OM4, 50um (aqua sheath) 82

83 Building Management Systems 3. UC FIBRE MB SERIES 212 Core, Indoor, Breakout, Tight Buffer Distribution Cable, LSZH 3.5 Fibre Optic Cables Features Buffer Coating : LSZH, 0.9mm tight buffered fibre. Strength Member : Aramid yarn within each subunit Subunit sheath : LSZH Central Strength Member Outer Sheath : LSZH compliant to IEC 61034, IEC &2, IEC & and also in flame retardant, low smoke and halogen free environments. Main Characteristics Test Standard Value Sanction* Maximum Tension at installation (short term) Tension opération max (long term) IEC E1 600N Δl/l fibre 0.6%, Δα reversible IEC E1 198N Δl/l fibre 0.2%, Δα 0. db(sm)/ 0.40 db(mm) Crush IEC E3 0 N / mm Δα 0. db(sm)/ 0.40 db(mm), cable integrity * values for multimode fibres, all optical measurements performed at 10 nm values for singlemode fibres, all optical measurements performed at 1550 nm Overview MB Series provides easy stripping and terminations in indoor application due to its unique tight buffering of each fibre unit. Additional Options applications applications armouring protection IEC , IEC /2 Technical Data 0.9 ± 0.05 No. of Fibres 2, Design Breakout Buffer Diameter Ø mm 0.9 ± ± ± ± 0.05 CSM/sheath diameter mm 1.0 nominal 1.0/2.2 nominal 2.0/3.5 nominal 2.0/6.2 nominal Subunit sheath thickness mm 0.35 nominal 0.35 nominal 0.35 nominal 0.35 nominal Subunits diameter mm 2.0 ± ± ± ± 0.15 Outer sheath thickness mm 1.0 nominal 1.0 nominal 1.0 nominal 1.0 nominal Cable Diameter (AxB) mm 7.0 ± ± ± ± 0.5 Cable kg / km Min. bending radius Without Tension 10 CableØ Under Maximum Tension 20 CableØ Temperature range C Installation 10 > +60; Transport. & Storage 40 > +70 ; Operation 20 > +70 Flame Retardant IEC , IEC Ordering Information UC FIBRE MB SERIES FO Cable part numbers are made up using the table below. The part number always starts with the letters MB to denote that it is a UC FIBRE MB SERIES FO Cable. This is followed by 3 numbers which symbolises the core quantity and then 2 letters to denote the fibre type. FIBRE MB SERIES FO Cable part number: MB008M3 FIBRE MB SERIES FO Cable, with 8 cores. MB SERIES MB CORE QUANTITY XXX CORES CORES CORES CORES CORES FIBRE TYPE XX SM SINGEMODE, G652D, 9um (yellow sheath) M1 OM1, 62.5um (orange sheath) M2 OM2, 50um (orange sheath) M3 OM3, 50um (aqua sheath) M4 OM4, 50um (aqua sheath) 83

84 3. Building Management Systems 3.6 MultiPair Category Cables Category 3 UTP 25/50/x2x0.5 Multipair U/UTP Data Cable Construction These cables are used as riser cable in Stranding Subunits no. Pair no. Identification Wrapping Sheath Tensile force N Solid bare copper wire, diameter 0.5 mm Highdensity polyethylene HDPE 25 pairs stranded to sub units. Cables with pairs are built up with 1st layer: 3 basic units, 2nd layer: 7 basic units One Two Three Four 1 ~ ~ ~ ~ Pair 1 BlueWhite Pair 2 OrangeWhite Pair 3 GreenWhite Pair 4 BrownWhite Pair 5 GreyWhite Pair 6 BlueRed Pair 7 OrangeRed Pair 8 GreenRed Pair 10 GreyRed Pair 11 BlueBlack Pair 12 OrangeBlack Pair 13 GreenBlack Pair 14 BrownBlack Pair 15 GreyBlack Pair 16 BlueYellow Pair 17 OrangeYellow Pair 18 GreenYellow Pair 9 BrownRed Mylar Tape PVC Black, also available on request with LSZH Nom. 11.4(25pair) 23.8(pair PVC) mm Nom. 500(25pair) 2000(pair PVC) Pair 19 BrownYellow Pair 20 GreyYellow Pair 21 BlueViolet Pair 22 OrangeViolet Pair 23 GreenViolet Pair 24 BrownViolet Pair 25 GreyViolet Standards Mechanical Properties Minimum bending radius Without load 4 x D ( D= outer diameter ) Temperature With load During operation 8 x D ( D= outer diameter ) 20 C to + 60 C During operation 0 C to + 50 C Maximum DC Resistance Minimum DC Resistance Dielectric Strength (DC) resistance maximum unbalance percentage 95 Ω / km 5000 M Ω. km 1KV / min 2.5 % Frequency (MHZ) Max. Insertion Loss (db) Min. Return Loss (db) Min. NEXT (Test length> 0 m) (db) Min. ELFEXT (db) (nominal value) (nominal value) Min. PSELFEXT (db/m) Max. DELAY (db/m) Technical Data Type Outer diameter mm Standard delivery length m Tensile force N 25 x 2 x 0.5 Cat. 3 PVC 50 x 2 x 0.5 Cat. 3 PVC x 2 x 0.5 Cat. 3 PVC 25 x 2 x 0.5 Cat. 3 LSZH 50 x 2 x 0.5 Cat. 3 LSZH x 2 x 0.5 Cat. 3 LSZH 12.4 ± ± ± tba Category 3 U/UTP 25 X 2 X 0.5 Multipair PVC tba tba tba Category 3 U/UTP 50 X 2 X 0.5 Multipair PVC Category 3 U/UTP X 2 X 0.5 Multipair PVC Category 3 U/UTP 25 X 2 X 0.5 Multipair LSZH tba tba Category 3 U/UTP 50 X 2 X 0.5 Multipair LSZH Category 3 U/UTP X 2 X 0.5 Multipair LSZH 84

85 Category 5e 25/50/x2x0.5 Multipair U/UTP Symmetrical Data Cable Building Management Systems 3.6 MultiPair Category Cables 3. Twisting Sub unit stranding Main unit stranding Identification Sheath Tensile force N Minimum bending radius Temperature Bare copper wire, diameter 0.52 mm (AWG24) PE, diameter 0.95 mm 2 cores to pair, diameter 1.9 mm 5 pairs to subunit + filler, diameter 5.0 mm 5 subunits to a 25 unit + filler PET foil wrapping Pair 1 BlueWhite Pair 2 OrangeWhite Pair 3 GreenWhite Pair 4 BrownWhite Pair 5 GreyWhite Pair 6 BlueRed Pair 7 OrangeRed Pair 8 GreenRed Without load With load During operation During operation Pair 10 GreyRed Pair 11 BlueBlack Pair 12 OrangeBlack Pair 13 GreenBlack Pair 14 BrownBlack Pair 15 GreyBlack Pair 16 BlueYellow Pair 17 OrangeYellow Pair 9 BrownRed Pair 18 GreenYellow PVC or LSZH, diameter 15.5 mm grey, RAL 7035 Nom. 15.5(25pair) 35.8(pair PVC) mm Nom. 207(25pair) LSZH 920(pair PVC) kg/km Nom. 500(25 pair) 2000(pair) Pair 19 BrownYellow Pair 20 GreyYellow Pair 21 BlueViolet Pair 22 OrangeViolet Pair 23 GreenViolet Pair 24 BrownViolet Pair 25 GreyViolet 60 mm 120 mm 20 C to + 60 C 0 C to + 50 C Standards Loop resistance Resistance unbalance Test voltage Mutual capacitance Capacitance unbalance Mean characteristic impedance Nominal velocity of propagation resistance core/core 800 Hz pair/ground MHz 500 V 1 Ω/km 2% 0 VDC 1 min Nom. 48 nf/km 1500 pf/km Ω ± 5 Ω ca. 67% 2000 MΩ*km F (MHZ) Attenuation NEXT PSNEXT ACR PSACR (db/m) (db) (db) (db/m) (db/m) ELFEXT (db/m) PSELFEXT (db/m) Return loss (db) (31) S2YY, 25x2x0.52 Cat.5e, U/UTP Symmetrical Data Cable, Category 5e 25/50/x2x0.5 Multipair tbd (5651) S2YY, 50x2x0.52 Cat.5e, U/UTP Symmetrical Data Cable, Category 5e 25/50/x2x0.5 Multipair tbd S2YY, x2x0.52 Cat.5e, U/UTP Symmetrical Data Cable, Category 5e 25/50/x2x0.5 Multipair (3318) S2YH, 25x2x0.52 Cat.5e LSZH, U/UTP Symmetrical Data Cable, Category 5e 25/50/x2x0.5 Multipair (3319) S2YH, 250x2x0.52 Cat.5e LSZH, U/UTP Symmetrical Data Cable, Category 5e 25/50/x2x0.5 Multipair (3320) S2YH, x2x0.52 Cat.5e LSZH, U/UTP Symmetrical Data Cable, Category 5e 25/50/x2x0.5 Multipair 85

86 4. Broadcasting & Studio 4. Broadcasting & Studio Quality cables for the transmission of digital and analogue audio and video signals to professional levels RANKED AS NUMBER ONE IN EUROPE, DRAKA IS A LEADING PROVIDER OF PROFESSIONAL BROADCAST AND STUDIO CABLES. SINCE 1958 DRAKA BROADCAST SOLUTIONS HAVE DELIVERED LEVELS OF TECHNICAL EXCELLENCE THAT HAVE PROVEN THEMSELVES IN PRACTICE UNDER THE MOST DEMANDING CONDITIONS. Draka broadcast cables are optimally tailored to an information and entertainment market which is now spanning the analogue and digital world. Whether broadcasting a regional traffic report by a local radio station or the transmission of a World Class soccer into the world the success of broadcast production always depends on the reliability of the audio, video, camera and lighting control cables. Draka has decades of experience in the cable manufacturing, research and development in close cooperation with broadcasting professionals. Inspiring partnerships Since the beginning of professional broadcasting, Draka has worked in close cooperation with leading national and international broadcasting companies. Leading edge solutions in the form of highquality analogue, SDI, HDTV and hybrid fiber optic arise from these partnerships. With billion viewers around the globe, the World Cup 2006 in Germany, for example, was the mostwatched event in television history during a period of 4 weeks. Draka delivered the cables necessary for this new record and enabled broadcasts in HDTV for the first time. Draka also supported Euro Masters 2008 in Austria and Switzerland. Draka meets the specifications of national broadcasters as well as with AES/EBU, SMPTE, IEC, EN and VDE. Leading sound studios are users of Draka cables. Superior quality of sound requires cutting edge technology where cabling is an essential link. In this field, Draka offers modern cable solutions for analogue and digital recording as well as for microphone and speaker cabling. As one of the world s leading manufacturers of passive network cables, Draka can guarantee the high efficiency of passive transmission cables which are produced using the latest technology. For live events, there is only a single chance for a successful performance. There is no alternative to absolute reliability. Draka offe rs the best solutions for lighting control, sound, microphone and speaker interconnections and can quickly respond to the requirements of production companies in order to guarantee an optimum live performance. Comprehensive product line The studio broadcast solutions of Draka comprise: Highprecision analogue and digital 75 Ω video cables Analogue and digital multicore audio cables Microphone cables, speaker cables Lighting control and Sound cables Camera cables for studio and outdoor transmission Multicore camera cables Studio connecting cables Hybrid camera cables 86

87 Broadcasting & Studio Video Cables 0.6/2.8 AF S 1.0/4.8 AF 1.6/7.3 AF HD PRO 0.6/2.8 AF AC10 SS 23/1 nxp AC10 SS 26/7 x pairs XLR PRO FLEX analogue / digital Triax Cables SMPTE 311MHDHybridCamera Cable

88 4. Broadcasting & Studio 0.6/2.8 AF S Video Cable 75 Ω Construction IInner conductor Outer conductor Sheath Tensile force N solid copper wire, bare, diameter 0.6 mm FoamPE, diameter 2.8 mm AlPETPAlfoil under tinned copper braid, diameter 3.4 mm LSZH, diameter 4.5 mm green, RAL 6018 Nom. 28 kg/km 60 Video cables are primary used in closed circuit TV systems and in several studio applications for transmission of image signals. Standards For analogue and digital video signals (Composite, component, SDI, SDV, SDTI, HDTV) Electrical Properties at 20 C DC resistance Mutual capacitance Characteristic impedance Velocity ratio Screening factor Inner conductor Outer conductor 61 Ω/km 17 Ω/km 56 pf/m 75 Ω ± 0.75 Ω 78 % > db Attenuation (db/m) Frequency (MHz) Ordering Information Return loss (db) Frequency (MHz) /2.8 AF S LSZHC green, Video Cable 75 Ω, 0.6/2.8 AF S 88

89 1.0/4.8 AF Video Cable 75 Ω Broadcasting & Studio 4. Construction Inner conductor Outer conductor Sheath Tensile force N solid copper wire, bare, diameter 1.0 mm FoamPE, diameter 4.8 mm AlPETAlfoil under tinned copper braid, diameter 5.6 mm LSZH, PVC, PUR diameter 7.0 mm green, RAL 6018, blue, RAL 5015 Nom. 69 kg/km 140 Electrical Properties at 20 C DC resistance Mutual capacitance Characteristic impedance Velocity ratio Screening factor Electrical Data at 20 C Attenuation (db/m) Frequency (MHz) Inner conductor Outer conductor Return loss (db) Frequency (MHz) Ω/km 7 Ω/km 56 pf/m 75 Ω ± 0.75 Ω 78 % db Video cables are primary used in closed circuit TV systems and in several studio applications for transmission of image signals. Standards For analogue and digital video signals (Composite, Component, SDI, SDV, SDTI, HDTV) Ordering Information 2208 CT /4.8 AF LSZHC green, Video Cable 75 Ω, 1.0/4.8 AF 2209 CT /4.8 AF LSZHC green, Video Cable 75 Ω, 1.0/4.8 AF 2210 CT /4.8 AF LSZHC green, Video Cable 75 Ω, 1.0/4.8 AF 2198 CT /4.8 AF PVC green, Video Cable 75 Ω, 1.0/4.8 AF 2199 CT /4.8 AF PVC blue, Video Cable 75 Ω, 1.0/4.8 AF 89

90 4. Broadcasting & Studio 1.6/7.3 AF Video Cable 75 Ω Construction Inner conductor Outer conductor Sheath Tensile force N solid copper wire, bare, diameter 1.6 mm FoamPE, diameter 7.3 mm AlPETAlfoil under tinned copper braid, diameter 8.2 mm LSZH, diameter 10.3 mm green, RAL 6018 Nom. 120(PUR) 135(LSZH) kg/km 270 Video cables are primary used in closed circuit TV systems and in several studio applications for transmission of image signals. Standards For analogue and digital video signals (Composite, Component, SDI, SDV, SDTI, HDTV) Electrical Properties at 20 C DC resistance Mutual capacitance Characteristic impedance Velocity ratio Screening factor Electrical Data at 20 C Attenuation (db/m) Frequency (MHz) Inner conductor Outer conductor Return loss (db) Frequency (MHz) Ω/km 4.3 Ω/km 56 pf/m 75 Ω ± 0.75 Ω 78 % db Ordering Information 2202 CT /7.3 AF LSZHC gn, Video Cable 75 Ω, 1.6/7.3 AF 21 CT /7.3 AF PVC green, Video Cable 75 Ω, 1.6/7.3 AF 2461 CT /7.3 AF PUR green, Video Cable 75 Ω, 1.6/7.3 AF 2462 CT /7.3 AF PUR blue, Video Cable 75 Ω, 1.6/7.3 AF

91 HD PRO 0.6/2.8 AF HD Video Cable 75 Ω Broadcasting & Studio 4. Construction Inner conductor Outer conductor Sheath Tensile force N solid copper wire, bare, diameter 1.0 mm FoamPE, diameter 4.8 mm AlPETAlfoil under tinned copper braid, diameter 5.6 mm LSZH, PVC, PUR diameter 7.0 mm green, RAL 6018, blue, RAL 5015 Nom. 28 kg/km 60 Electrical Properties at 20 C DC resistance Mutual capacitance Characteristic impedance Velocity ratio Screening factor Inner conductor Outer conductor 22 Ω/km 7 Ω/km 56 pf/m 75 Ω ± 0.75 Ω 78 % db Video cables are primary used in closed circuit TV systems and in several studio applications for transmission of image signals. Standards For analogue and digital video signals (Composite, component, SDI, SDV, SDTI, HDTV) IEC /2, IEC , IEC Electrical Data at 20 C Attenuation (db/m) Frequency (MHz) Return loss (db) Frequency (MHz) Ordering Information HD PRO 0.6/2.8 AF, HD Video Cable 75 Ω, HD PRO 0.6/2.8 AF 91

92 4. Broadcasting & Studio Standards Basing upon ARDSpecification and acc. to AES/EBURecommendation.) or 3323 cat. CF AC10 SS 23/1 nxp Audio Cable Construction Pair stranding Pair identification Pair screen Pair insulation of the one pair cable Overall screen of the one pair cable Pair sheath of the multipair cables Colour and identification Sheath Sheath colour Tensile force N Bending radius during installation Temperature range BendaDC loop resistance resistance Mutual capacitance at 800 Hz Capacitance unbalance (pair to ground) Velocity ratio Test voltage (50 Hz, 1 min) core/core and core/screen Characteristic impedance Transfer impedance solid copper wire, bare 0.56 mm (cross section 0.26 mm²) FoamskinPE Two cores twisted to the pair a core: white, b core: blue (the above colours in regular intervals) AlPETfoil, Aluminium outside + solid copper drain wire, tinned PETfoil copper braid, tinned halogen free, flame retardant copolymere grey RAL 7001 with number printing halogen free, flame retardant copolymere grey, RAL 7001 Nom. 4.6(1pair) 15.6(12pair) mm Nom. 27(1pair) 320 (12pair) kg/km Nom. 80(1pair) 725(12pair) with load without load 0 AWG23/ mm mm 15 x cable diameter 10 x cable diameter C bis + 70 C 165 Ω/km 2000 MΩxkm nom. 45 nf/km 1200 pf/km approx. 78 % 700 V rms 6 MHz : 110 Ω ± 10% up to 10 MHz up to MHz 10 mω/m mω/m Frequency (MHz) Nearend crosstalk (cable length: 0 m) Attenuation Draka Multimedia Cable Measurement values Draka Multimedia Cable Measurement values neighboured pairs [db] unneighboured pairs [db] [db/m] CT x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxp 2115 CT x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxp 2106 CT x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxp 2108 CT x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxp 2109 CT x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxp 2103 CT x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxp 2111 CT x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxp 2113 CT x2x0.56 PiMF, Audio Cable, AC10 SS 23/1 nxp 92

93 AC10 SS 26/7 x pairs Audio Cable Construction Pair stranding Pair identification Pair screen Pair insulation of the one pair cable Pair sheath of the multipair cables Colour and identification Cable lay up Overall screen Sheath Sheath colour Tensile force N Bending radius during installation Temperature range Fire propagation stranded copper wires, bare 0.48 mm (cross section 0.14 mm² ) FoamskinPE two cores twisted to the pair a core: white, b core: blue (the above colours in regular intervals) AlPETfoil, Aluminum inside + stranded copper drain wires, tinned PETfoil, FRNC, flame retardant grey RAL 7001 with number printing n pairs twisted in layers Al PETfoil + copper braid, tinned LSZHC grey, RAL 7001 Nom. 4.2(1pair) 19.5(24pair) mm Nom. 23(1pair) 395(24pair) kg/km Nom. 50(1pair) 1325(24pair) with load without load DC loop resistance (at 20 ± 5 C) resistance (at 20 ± 5 C and 500 V) Mutual capacitance at 800 Hz Capacitance unbalance (pair to ground) Velocity ratio Test voltage (50 Hz, 1 min) core/core and core/screen Characteristic impedance Transfer impedance 288 Ω/km 2000 MΩxkm nom. 45 nf/km 1200 pf/km approx. 78 % 700 V rms 0 AWG26/7 mm mm mm mm 10 x cable diameter 15 x cable diameter C up to + 70 C VDE 0472 part 804 class B or C and IEC 3321 or 3323 cat. CF 6 MHz : 110 Ω ± 10% up to 10 MHz up to MHz 10 mω/m mω/m Broadcasting & Studio Standards Basing upon ARDSpecification and acc. to AES/EBURecommendation.) 4. Frequency (MHz) Nearend crosstalk (cable length: 0 m) Attenuation Draka Multimedia Cable Measurement values Draka Multimedia Cable Measurement values neighboured pairs [db] unneighboured pairs [db] [db/m] CT Li02YSCH, 1x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 2147 CT Li02YS(St)CH, 2x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 2125 CT Li02YS(St)CH, 3x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 2129 CT Li02YS(St)CH, 4x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 2131 CT Li02YS(St)CH, 6x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 2142 CT Li02YS(St)CH, 8x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 2134 CT Li02YS(St)CH, 10x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 2137 CT Li02YS(St)CH, 12x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 2140 CT Li02YS(St)CH, 16x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs CT Li02YS(St)CH, 20x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 75 CT Li02YS(St)CH, 24x2x0.48L PiMF, Audio Cable, AC10 SS 26/7 x pairs 93

94 4. Broadcasting & Studio XLR PRO FLEX analogue / digital Construction Identification Stranding Screen Sheath Tensile force N stranded copper wires, bare, diameter 0.60 mm FoamPE + skinlayer, diameter 1.5 mm a core: white; b core: blue two cores twisted to the bundle + cotton filler, diameter 3.0 mm spiralled wires, CU bare, diameter 3.2 mm DMC FLEX PVC, diameter 6.5 mm ± 0.2 mm black, RAL 05 Nom. 6.5 mm Nom. 50 kg/km 55 Mechanical Properties Audio cables are used in professional broadcasting systems for the transmission of analogue and digital audio signals. Minimum bending radius Temperature range without load with load during operation during installation 4 x D ( D= outer diameter ) 8 x D ( D= outer diameter ) C to + 70 C 5 C to + 50 C Standards AES/EBU and analogue Audio Electrical Properties at 20 C Loop resistance resistance Mutual capacitance Velocity ratio Test voltage Characteristic impedance 500 V 800 Hz (DC. 1 min) core/core and core/screen 6 MHz 175 Ω/km 2000 MΩ*km nom. 45 nf/km ca.78% 0 V 110 Ω ± 10 % Electrical Data at 20 C Frequency (MHz) Attenuation (db/m) Ordering Information x2x0.22², XLR PRO FLEX analogue / digital 94

95 Triax Cables Triaxial Camera Cables Broadcasting & Studio 4. Construction Inner conductor 1st outer conductor 2nd outer conductor Sheath Tensile force N solid copper wire, silvered or stranded copper wires, silvered FoamPE copper braid, thick silvered PE copper braid, bare PVC, PU (standard or reinforced type) or LSZH red, RAL 00 altern. black or grey (Triax8PU) 250(Triax 14 PVC) mm 85(Triax8PU) 550(Triax 14 PVC) Dimensions Inner conductor copper wire, silvered stranded copper wires, silvered foampe Inner screen copper braid, silvered PE Outer screen copper braid, bare Sheath red, RAL 00 reinforced, sign/1 Sheath marking (example: PVC sheath) Triax 8 Ø 1.0 mm Ø 4.5 mm Ø 5.1 mm Ø 6.6 mm Ø 7.2 mm Ø 8.4 mm Ø 8.9 mm "DRAKA TRIAX 8 Y HDTV" + batch no. Triax 11, Triax 11/1 Ø 1.4 mm Ø 6.5 mm Ø 7.1 mm Ø 8.6 mm Ø 9.2 mm Ø 10.9 mm Ø 12.2 mm "DRAKA TRIAX 11 Y HDTV" + batch no. AtteTriax 14ation Ø 2.2 mm Ø 9.7 mm Ø 10.5 mm Ø 11.9 mm Ø 12.7 mm Ø 14.5 mm "DRAKA TRIAX 14 Y HDTV" + batch no. Triaxial camera cables are used in professional studio applications for simultaneous transmission of energy and multiplex image signals between camera head and control system for SDI and HDSD. They are available as different types optimized for use inside studios and outdoor application. Electrical properties: Triax 8 at 20 C Characteristic impedance Mutual capacitance DC resistance resistance Max. operating voltage Screening factor 800 Hz inner conductor inner screen outer screen inner conductor/inner screen inner screen/outer screen 0 MHz 75 Ω ± 3 % 54 pf/m 25 Ω/km 12 Ω/km 10 Ω/km 104 MΩ*km 103 MΩ*km 0 V 75 db Electrical properties: Triax 11, Triax 11/1 at 20 C Characteristic impedance Mutual capacitance DC resistance resistance Max. operating voltage Screening factor 800 Hz inner conductor inner screen outer screen inner conductor/inner screen inner screen/outer screen 0 MHz 75 Ω ± 3 % 54 pf/m 13 Ω/km 10 Ω/km 8 Ω/km 104 MΩ*km 103 MΩ*km 400 V 75 db Electrical properties: Triax 14 Characteristic impedance Mutual capacitance DC resistance resistance 800 Hz inner conductor inner screen outer screen inner conductor/inner screen 75 Ω ± 3 % 54 pf/m 6 Ω/km 6 Ω/km 4 Ω/km 104 MΩ*km 95

96 4. Broadcasting & Studio Electrical Properties: Triax 8 at 20 C Attenuation (db/m) Frequency (MHz) Return loss (db) Frequency (MHz) Electrical Data: Triax 11, Triax 11/1 at 20 C Attenuation (db/m) Frequency (MHz) Return loss (db) Frequency (MHz) Electrical Data: Triax 14 at 20 C Attenuation (db/m) Frequency (MHz) Return loss (db) Frequency (MHz) Ordering Information 2223 CT Triax 8 PVC red, Triaxial Camera Cables, Triax Cables CT Triax 8 PVC black, Triaxial Camera Cables, Triax Cables 2221 CT Triax 8 PU, Triaxial Camera Cables, Triax Cables 2266 CT Triax 8 LSZH, Triaxial Camera Cables, Triax Cables 2268 CT Triax 8 LSZH reinforced, Triaxial Camera Cables, Triax Cables 2226 CT Triax 11 PVC, Triaxial Camera Cables, Triax Cables 2229 CT Triax 11 PE black, Triaxial Camera Cables, Triax Cables 2233 CT Triax 11 PU red, Triaxial Camera Cables, Triax Cables 2234 CT Triax 11 PU black, Triaxial Camera Cables, Triax Cables 2243 CT Triax 11/1 PU reinforced, Triaxial Camera Cables, Triax Cables 2264 CT Triax 11 LSZH, Triaxial Camera Cables, Triax Cables 2236 CT Triax 14 PVC, Triaxial Camera Cables, Triax Cables 2239 CT Triax 14 PE, Triaxial Camera Cables, Triax Cables 2273 CT Triax 14 LSZH, Triaxial Camera Cables, Triax Cables 2240 CT Triax 14 PU, Triaxial Camera Cables, Triax Cables 96

97 SMPTE 311MHDHybridCamera Cable HybridHDTVCamera Cable Construction Element 1: Auxiliary s AWG20 (4 x 0.6 mm 2 ) tinned stranded copper wires, 19 x 0.20 mm, diameter 1.0 mm HDPE, diameter 1.5 mm Identification 2 x black, 2 x white Element 2: Signal s AWG24 (2 x 0.22 mm 2 ) Identification tinned stranded copper wires, 7 x 0.20 mm, diameter 0.6 mm HDPE, diameter 1.1 mm 1 x red, 1 x grey Element 3: Fibre Optic Single Mode (2 x 9/125μ) Mode field diameter at 1310 nm, diameter 9.5 μm ± 1 μm Cladding diameter diameter 125 μm ± 1 μm Concentricity error 1 μm Coating material UVcrosslinked Acrylate, diameter 245 μm Buffer material Thermoplastic, diameter 0.9 μm ± 0.05 μm Identification 1 x blue, 1x yellow Element 4: Strength Member AWG16 (1 x 1.22 mm 2 ) Identification Cable lay up Stranding Wrapping Screen Sheath Tensile force N galvanized steel wires, diameter 1.6 mm HDPE, diameter 2.1 mm 1 x white Core: 1 x Element 4, diameter 2.1 mm Layer: 4 x Element x Element x Element 3 and in the outer interstices 4 x fibrillated Polypropylene as needed for roundness, diameter 5.2 mm Sequence according to the above drawing 1 x nonwoven fabric tape, diameter 5.4 mm Copper wire braid, tinned 95% opt. coverage, diameter 5.9 mm PUR or LSZH, diameter 9.2 mm black, RAL 05 Nom. 115 kg/km Nom. 800 Broadcasting & Studio This Hybrid HD Camera Cable 2SM 9/ x AWG x AWG24 acc. to SMPTE 311MStandard contains SingleMode Optical Fibres, Auxiliary and Signal s. It is used in professional video productions for simultaneous transmission of energy, video, audio and control signals and is intended to interconnect Camera Units and Base Stations in conjunction with the Connector Interface Standard. It is suitable for all new digital camera systems of wellknown manufacturers. Standards SMPTE 311M 4. Mechanical Properties at 20 C Temperature range PUR (LSZH) Max. humidity during operation 40 C to + 70 C ( 25 C to +70 C) 95 % IEC , IEC , IEC Electrical Properties at 20 C Auxiliary s AWG20 (4 x 0.6 mm 2 ) DC resistance Loop resistance resistance Test voltage Operating voltage Signal s AWG24 (2 x 0.22 mm 2 ) DC resistance Loop resistance resistance Test voltage Operating voltage Overall screen DC resistance Optical Properties Fibre Optic Single Mode (2 x 9/125μ) Cutoff wavelength Attenuation Dispersion Ordering Information at 1310 nm at 1310 nm 35.3 Ω/km 43 Ω/km 104 MΩ*km 1750 VAC rms 0 VAC rms.5 Ω/km 184 Ω/km 104 MΩ*km 1750 VAC rms 0 VAC rms 20 Ω/km nm 0.5 db 3.5 ps/nm*km 2458 CT29000 glossy SMPTE 311M Hybrid Camera Cable, HybridHDTVCamera Cable, SMPTE 311MHDHybridCamera Cable 8069 CT29002 dull SMPTE 311M Hybrid Camera Cable, HybridHDTVCamera Cable, SMPTE 311MHDHybridCamera Cable CT76000 SMPTE 311M Hybrid Camera Cable LSZH, HybridHDTVCamera Cable, SMPTE 311MHDHybridCamera Cable

98 Services and related documents Certified engineers enjoy full vendor support before, during and after completion of their projects. Before Already before your project commences we are there to train you on all features of Draka UC cabling system. If you are an experienced professional or still improving your engineering skills it o ers you the right mix of theory and practice to get you going better. Take advantage of a world leading manufacturer s resources. UC CONNECT The LAN connectivity system ENDTOEND CABLING SOLUTIONS FOR NETWORKS TO LAST During If your project is fully running and you face an issue trust in our experienced infield support. You will not be alone if there are questions about testing, standards or installation practices. If there is uncertainty about your specification, we are there to give you support. After Needless to say the 3rd party approved Draka solutions are entirely covered by an endtoend system warranty. Please contact our local offices to enquire about the Draka UC Structure Cabling System Warranty Program. UC CONNECT The LAN connectivity system From the World s Largest Cable Manufacturer Used extensively in: Data Ce ntres Enterpr ise Buildin gs Industr stria l Airport orts Institu tions Warranty Program Overview for Draka UC Structure Cabling System 1 Abrandofthe Draka UC Structure Cabling Warranty UC CONNECT 3 rd party approvals 98

99 UC FIBRE Optical Fibre Cable UC Data Cable UC CONNECT Installation Guidelines Mobile Networks 99

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4 Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T

More information

NETWORK CONNECTIVITY SYSTEMS

NETWORK CONNECTIVITY SYSTEMS NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation

More information

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2 Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded

More information

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y

More information

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation

More information

Cables for data transmission in industrial automation

Cables for data transmission in industrial automation Cables for data transmission in industrial automation The Quality Connection The LEONI Group Cable expertise for the most various industrial markets. LEONI is a leading supplier of cable systems and related

More information

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Ship and Offhsore. Approved cables for ship- and offshoreindustry Ship and Offhsore Approved cables for ship- and offshoreindustry NEK Kabel AS - Norway. (NEK Sealine Marine products) tel. +47 67 91 21 80 - Firmapost@nek-kabel.no 1 OVER 100 YEARS OF EXPERIENCE 1913-2013

More information

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications... Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic

More information

INDUSTRIAL DATA LAND. The best solution for the industrial automation.

INDUSTRIAL DATA LAND. The best solution for the industrial automation. The best solution for the industrial automation www.ceamcavi.it There is a quality, in CEAM s production, that goes beyond the features of each single cable, a value which involves all the company processes

More information

UNIRAIL D RS485 and BUS cables

UNIRAIL D RS485 and BUS cables UNIRAIL D RS485 and BUS cables Type: 1x2x22 AWG/7 + 1x22 AWG/7 (1x2x0,35 + 1x0,35) Code: RW103A stranded tinned copper wire 22 AWG/7 (0,35 mm²) white blue POWER ELEMENTS: stranded bare copper wire 22 AWG/7

More information

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables Cables for Data Transmission in Industrial Automation Fieldbus Cables Copper Cables Fibre Optic Cables 2 KERPEN GmbH & Co. KG 2005 2.2006 Printing errors excepted. Subject to alteration. Contents Seite

More information

Marine Cables General Catalogue

Marine Cables General Catalogue Marine Cables General Catalogue Marine Cables Special cables for civil and defence ship applications General catalogue Linking the Future As the worldwide leader in the cable industry, Prysmian Group believes

More information

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications. Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001 Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001-10 Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

More information

Product information. Marine, Oil & Gas.

Product information. Marine, Oil & Gas. Product information Marine, Oil & Gas www.drakamog.com DRAKA Product information MOG 2010 Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded

More information

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded

More information

Category 6 UTP EuroClass C ca Cables

Category 6 UTP EuroClass C ca Cables Category 6 UTP EuroClass C ca Cables Datasheet: GD103704v1 APPLICATION Brand-Rex Cat6Plus C6U cables exceed the Category 6 performance standards. They are rated to 250MHz and are suitable for use in all

More information

Copyright June Nexans

Copyright June Nexans Nexans is the worldwide leader in the cable industry, with an industrial presence in 29 countries and commercial activities in 65 countries. Nexans brings an extensive range of advanced copper and optical

More information

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction: Addison www.addison-tech.com www.addison-cables.com Profibus SK Indoor + Outdoor Application: The application of these Profibus SK cables are in the cell and field area, just as for conventional types.

More information

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and

More information

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

K20 & L120 LSZH Armoured F/FTP Cat6 Cables K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE

More information

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction: Caledonian www.caledonian-cables.co.uk www.caledonian-cables.net Profibus L2 Indoor Application: This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the

More information

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH FIGURE CONSTRUCTION Inner conductor CCA Φ 0.50±0.01mm Insulation Solid HDPE Φ 0.90±0.05mm Color 1 Blue & White/ Blue 2 Orange & White/ Orange 3 Green & White/

More information

MULTIMEDIA CABLE H6091ZHB

MULTIMEDIA CABLE H6091ZHB CAVEL News MULTIMEDIA CABLE H6091ZHB MULTIMEDIA CABLE H6091ZHB Multimedia is a must in the modern way of life. Growing communication needs in any environment whether at home or the office the connection

More information

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation

More information

Bus Cables HELUKABEL

Bus Cables HELUKABEL Photo: HELUKABEL Bus Cables HELUKABEL Bus technology is being used in an increasing number of industrial applications. This technology can be applied in every branch in industry where processcontrol techniques

More information

Selection table for flat & ribbon cables

Selection table for flat & ribbon cables Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON

More information

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CUSTOM DESIGN COAXIAL CABLES BY SICAB CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency

More information

Information technology. Generic cabling systems, General requirements

Information technology. Generic cabling systems, General requirements KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.

More information

CAT 5e UTP Cable: NETSET BOX [305m], indoor

CAT 5e UTP Cable: NETSET BOX [305m], indoor Code: E08_05 CAT 5e UTP Cable: NETSET BOX [05m], indoor NETSET BOX UTP 5e Ethernet cable far exceeds the requirements for Category 5e twisted pair cables. View of the cable box - inside 05m of the cable.

More information

Category 6 A F/FTP Euroclass C ca Cables

Category 6 A F/FTP Euroclass C ca Cables Category 6 A F/FTP Euroclass C ca s Datasheet: GD103266v2 APPLICATION The Brand-Rex AC6F/FTP C ca cables are compliant with the European Construction Products Regulation, achieving Euroclass level C ca

More information

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for

More information

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated

More information

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires

More information

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective

More information

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums 4.3-10 Coax Serie Coaxial Cables HF Steckverbinder für Mobilfunk-Anwendungen in Bulk Rings or on Cable Drums Coaxial Cables In addition to the wide range of coaxial connectors, Telegärtner offers suitable

More information

MULTIMEDIA & DATA TRANSMISSION

MULTIMEDIA & DATA TRANSMISSION NEXANS, every c a b l e t h a t m a k e s a t r a i n r o l l Whoever you are, rolling stock OEM, subsystem supplier or operator, Nexans provides everything from energy & telecom cable to integrated cabling

More information

Contents. Category7 SSTP Solid Indoor Cable - Page 03

Contents. Category7 SSTP Solid Indoor Cable - Page 03 Product Catalog Contents Category7 SSTP Solid Indoor Cable - Page 03 Category6A UTP Solid Indoor Cable - Page 04 Category6A Keystone Jack - Page 05 Category6A Unshielded Patch Cord - Page 05 Category6

More information

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)

More information

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT TPE-INSULATED CABLES Products TPE - Cables TPE-INSULATED CABLES 105 C O N T E N T S C O N T E N T S Page TPE single cores according to DIN 72551, type A 107 TPE single cores according to DIN 72551, type

More information

Armoured Instrumentation Cables to BS6883

Armoured Instrumentation Cables to BS6883 Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring

More information

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Overview Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Example drawing (see the chapter belonging to the cable for details) (see the chapter belonging

More information

The Quality Connection. ICON Product Guide

The Quality Connection. ICON Product Guide The Quality Connection ICON Product Guide 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for special applications Instrumentation-

More information

Install & Go Cat.8 STP Trunk Cable Assembly Description

Install & Go Cat.8 STP Trunk Cable Assembly Description Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Banana Peel Composite - (2) Cat 5e 4-pair 24 AWG unshielded plus (2) Series 6 Coax with Duobond IV Quad shield, polyolefin insulation on the

More information

PRODUCT INFORMATION UNITRONIC BUS PB

PRODUCT INFORMATION UNITRONIC BUS PB Fixed installation These bus cables can be used for PROFIBUS-DP, PROFIBUS-FMS and FIP. Available with Fast Connect and halogen-free. Info Lapp Kabel is a member of the PROFIBUS user organisation (PNO)

More information

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12-jack to RJ45-plug Ethernet connection line Cat.5, 4-pole, D-coded (IEC

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data RFP Specification #17-11125-C, Exhibit 2 Programmable Light Poles for BART Plaza ENGLISH MEASUREMENT VERSION 1502SB Multi-Conductor - Multimedia Control Cable For more Information please call 1-800-Belden1

More information

TRAXLINE CABLES FOR MOTION

TRAXLINE CABLES FOR MOTION TRAXLINE CABLES FOR MOTION CONTINUOUS BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS TRAXLINE PRE-ASSEMBLED CABLES FOR CABLE CARRIERS EDITION 5-2016 Cost-effective, reliable, durable cables

More information

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

Servo Cable Selection

Servo Cable Selection Servo Cables Servo Cable Selection Chainflex cable Jacket Shield Class Bending radius moving (factor x d) Temperature moving from/to F ( C) Oil-resistant V max. ft/s (m/s) unsupported V max. ft/s (m/s)

More information

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4 Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked

More information

BUS cable. BUS cable. Cables for use in automation- and communication technique.

BUS cable. BUS cable. Cables for use in automation- and communication technique. Cables for use in automation- and communication technique. Industrystandards like INTERBUS-S, CAN, PROFIBUS, SINEC L2, DEVICENET and PROFINET defi ne these cables. There are also halogen free cables for

More information

THE WORLD OF LAPP. Cables for power chains

THE WORLD OF LAPP. Cables for power chains THE WORLD OF LAPP Cables for power chains Tested to breaking (or making) point The new generation of premium cables for highly dynamic applications in power chains is growing ÖLFLEX SERVO FD/CHAIN New

More information

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor Part Number: Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor Product Description Four Cat 6 23 AW G solid bare copper conductors, bonded pair polypropylene insulation,

More information

Instrumentation Cable PLTC/ITC and TC Types

Instrumentation Cable PLTC/ITC and TC Types Instrumentation Cable PLTC/ITC and TC Types The Quality Connection 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for

More information

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

FieldLink MC at 20 x outer diameter Torsion

FieldLink MC at 20 x outer diameter Torsion Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation

More information

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance. H155A02 Part Number: H155A02 COAX RF H155 FRNC Product Description COAX RF H155 FRNC Product Specifications Application Application 1: Application 2: 50 Ohm low loss coaxial transmission cable designed

More information

CABLE.

CABLE. CABLE www.pcnet-cable.com.tw sales@pcnet-cable.com.tw PCnet Leading Your Net! PCnet was founded in 1985 and is a leading manufacturer of netwking industries. We provide a complete range of products f structured

More information

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc. ()TSCGEWOEU TEAX TTS-LWL 3,6/6 kv: Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high mechanical

More information

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)

More information

Product Bulletin. Belden DataTwist 4800 Cables

Product Bulletin. Belden DataTwist 4800 Cables Product Bulletin PB 296 Belden DataTwist 4800 Cables DataTwist 4800 UTP Cables provide significant headroom and robust data transmission performance for today s most demanding applications. The cables

More information

UC DATA CABLES - CAT 5,6, 7 & 8

UC DATA CABLES - CAT 5,6, 7 & 8 UC DATA CABLES - CAT 5,6, 7 & 8 Fast and reliable copper cables for network solutions Connecting communities with communications PRYSMIAN GROUP A MARKET LEADER IN THE TELECOM INDUSTRY As the worldwide

More information

Communication, Control, and Industrial Cable

Communication, Control, and Industrial Cable Communication, Control, and Industrial Cable Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 291 Get control of demanding applications T he broad

More information

Content. - DDF Frame Pair Screen Cable Pair Screen Cable

Content. - DDF Frame Pair Screen Cable Pair Screen Cable Content - 120 1.1 Ohm 120ohm DDF DDF Accessories Cables 1.1.1 2 Pair Screen Cable - DDF Frame 1.1.2 4 Pair Screen Cable - 120 Ohm 1.1.3 DDF 8 Pair Cable Screen Cable 1.1.4 16 Pair Screen Cable 1.1.5 50

More information

Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN. 10 GBit. ELine, MegaLine, FLine, GigaLine

Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN. 10 GBit. ELine, MegaLine, FLine, GigaLine COMPETENCE IN CABLE TECHNOLOGY ready for 0 GBit E t h e r n e t ELine, MegaLine, FLine, GigaLine Solutions@KERPEN Cabling systems for LAN Office, LAN Home, LAN Industry, Access Networks, MAN, WAN and SAN

More information

DNVGL-CP-0400 Edition December 2015

DNVGL-CP-0400 Edition December 2015 CLASS PROGRAMME Type approval DNVGL-CP-0400 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

SAC-5P- 1,5-PUR/M12FS SH

SAC-5P- 1,5-PUR/M12FS SH Extract from the online catalog SAC-5P- 1,5-PUR/M12FS SH Order No.: 1682935 Sensor/Actuator cable, 5-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Free conductor end M12, on Socket, straight

More information

Photo: HELUKABEL. Motor, Servo & Feedback Cables D 1

Photo: HELUKABEL. Motor, Servo & Feedback Cables D 1 Photo: HELUKABEL Motor, Servo & Feedback Cables D Motor, Servo & Feedback Cables A multitude of applications requires the construction of many special cables. Corresponding to the customers requirements,

More information

Motor, Servo & Feedback Cables

Motor, Servo & Feedback Cables Photo: HELUKABEL Motor, Servo & Feedback Cables D Motor, Servo & Feedback Cables A multitude of applications requires the construction of many special cables. Corresponding to the customers requirements,

More information

SUPERIOR MARINE CABLE SOLUTIONS

SUPERIOR MARINE CABLE SOLUTIONS SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

Data sheet Patch cord Cat.6 A AWG m yellow

Data sheet Patch cord Cat.6 A AWG m yellow Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification especially suitable for shielded and unshielded class E A systems fully shielded Cat.6 A patch

More information

DB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL

DB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101

More information

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...

More information

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010 (0,25mm) XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics

More information

Nexans Industrial Solutions PRODUCT CATALOG

Nexans Industrial Solutions PRODUCT CATALOG Nexans Industrial Solutions PRODUCT CATALOG i NEXANS BRINGS ENERGY TO LIFE COPPER CABLES Nexans brings energy to life through an extensive range of cables and cabling solutions that deliver increased performance

More information

ABOUT US ABOUT US 1 CRANE CABLES

ABOUT US ABOUT US 1 CRANE CABLES ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Coax (2-1505A Type) 20 AWG BC, GIFPE isulation, Duofoil plus TC braid (95% cv.), PVC inner jackets. Pairs (4-9451 Type): 22 AWG TC, PP insul.,

More information

Railway products. Edition 2014

Railway products. Edition 2014 Railway products Edition 2014 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components

More information

UTP Cat 5e cable (200 MHz) (PVC sheath)

UTP Cat 5e cable (200 MHz) (PVC sheath) JetLan is the only structured cabling system that includes all the passive components required for the installation or adaptation of your data network, as we include all the different types of high performance

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 24 AWG stranded (7x32) TC conductor, Datalene insulation, pairs individually shielded with bonded Beldfoil with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil

More information

SAC-3P- 5,0-PUR/M12FR SH

SAC-3P- 5,0-PUR/M12FR SH Extract from the online catalog SAC-3P- 5,0-PUR/M12FR SH Order No.: 1682838 Sensor/Actuator cable, 3-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Free conductor end, on Socket, angled M12,

More information

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485 Content Page Certificates 3 Industrial Cables Production 4-5 Industrial Cables of PJSC «Odeskabel» 6 КИФ-В for RS485 (CAN) КИФ-В 1х2х0,6; КИФ-В 1,5х2х0,6; КИФ-В 2х2х0,6; КИФ-В 3х,2х0,6; КИФ-В 4х2х0,6 8

More information

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813 with / without optical fibre elements 3.6/6 kv Contents: Letter code Construction details and voltage-classes Technical data 1 with / without optical fibre elements Letter code Flexible cables acc. to

More information

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock The Quality Connection Cable and Systems for Rolling Stock Business Unit Rolling Stock Consulting and Sales Cable solutions Phone +41 (0)62-288-8356 Fax +41 (0)62-288-8383 System solutions Phone +49 (0)9172-6844-11

More information

Instrumentation Cables

Instrumentation Cables around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards

More information

Amphenol Cable. Features Allows for mass termination Up to 64 conductors

Amphenol Cable. Features Allows for mass termination Up to 64 conductors G80.7mm Economical Flat Ribbon 94V-0 A G80 X X XX X FLAT RIBBON CABLE.7mm Up to 64 conductors VARIATION CODE Blank: Standard PACAGING LENGTH NUMBER OF CONDUCTORS : 500 Feet 09: 9 Position : 400 Feet 4:

More information

INTRODUCTION PRODUCT LINES GREEN ENERGY. In drive technology, the trend is towards ever more complex

INTRODUCTION PRODUCT LINES GREEN ENERGY. In drive technology, the trend is towards ever more complex INTRODUCTION In drive technology, the trend is towards ever more complex cable systems. The quantity of data and speed of transmission are simultaneously rising rapidly. Interference-proof, fixed and dynamic

More information

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no) GameChanger Cable Unshielded Twisted Pair Riser Rated - CMR 258310333 46224PRYWB (legacy part no) 1.0 Scope 1.1 This cable consists of 4 pair solid bare copper; color-coded high density polyethylene (HDPE)

More information

SUBMERSIBLE PUMP CABLES

SUBMERSIBLE PUMP CABLES 12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum

More information

kv: medium voltage reeling cable with fibreoptics

kv: medium voltage reeling cable with fibreoptics PROTOLO(SMK)-LWL ()TSKCGEWOEU 3,6/6 kv: medium voltage reeling cable with fibre-optics Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy

More information