5. User-Centered Design Focus - High mobility cart - 19" formate high resolution Flat panel LCD display monitor or more - User adjustable control pane

Size: px
Start display at page:

Download "5. User-Centered Design Focus - High mobility cart - 19" formate high resolution Flat panel LCD display monitor or more - User adjustable control pane"

Transcription

1 A. SPECIFICATIONS : 1. Applications - Abdominal - Small Parts - OB/GYN - Vascular - Breast etc. 2. Imaging Modes - Adaptive Broadband flow imaging or Digital broad bandwith imaging or Advanced Dynamic Flow imaging or Broadband Color doppler or similar - SonoCT Real-time Compound Imaging or HI COM Realtime image compounding or ApliPure Realtime compounding or SuperCompound or CrossXbeam - XRES Adaptive Image Processing or HI REZ+ realtime tissue filter or ApliPure+ or SuperRes or SRI-HD or similar - Contrast Specific Imaging (CSI) or Dynamic contrast imaging or Contrast imaging function or Contrast Imaging or similar - Tissue Harmonic Imaging(THI) or Dynamic Tissue Harmonic Imaging(dTHI) or Differential Tissue Harmonic technology or Tissue Harmonic imaging or Coded harmonic Image or similar - Tissue Harmonic SonoCT Imaging or dthi with HI Com or THI with Aplipure or Tissue Harmonic imaging with SuperCompound - ISCAN with AGC or Patient Dependent Correction(PDC) or Q-scan or Auto TGC or Automatic Optimization - Pulsed Wave Doppler or similar - High Definition Zoom mode or similar - Reconstruction zoom with pan or similar - Dupplex and simultaneous 2D/ PW Doppler or similar - Independent Triplex for simultaneous 2D/Color/PW or similar - High Q control or Real-time Doppler Auto Trace or Tissue Doppler Imaging Quantification (TDI-Q) or Measurment package or similar - Panoramic Image or Wide View panoramic imaging or Panoramic View or Panoramic Image 3. Gray Shades - 256(8 bits) in 2D, Doppler spectral analysis or similar - 64(6 bits) in M-mode or similar 4. Acquisition frame Rate : 500f/s or more

2 5. User-Centered Design Focus - High mobility cart - 19" formate high resolution Flat panel LCD display monitor or more - User adjustable control panel lighting - Built-in A/C line conditioner provides isolation from voltage fluctuations and electrical noise interference - Four high-capacity fans with automatic speed adjustment to optimize cooling efficiency with audible noise 6. System Architecture - XSTREAM system architecture or HI Vision hispeed image processing or istyle ergonmic and Workflow package or SonicSoftware - Next generation digital broadband acoustic beamforming built for latest pulse shaping and coding techniques - 80dB full time input dynamic range or more - 56,000 digital channels or more - Multi-application workflow Protocols 7. Image Presentation - Up / down - Left / right - Multiple duplex image formats (1/3-2/3, 1/ 2-1/2, 2/3-1/3,50/50 and full screen ) 8. Adaptive Broadband flow imaging or Digital broad bandwidth imaging or Advanced Dynamic Flow imaging or Broadband color flow imaging - Automatically adapts transmit and receive bandwidth processing based on color box position providing optimal sensitivity and color resolution - Available in all image transducers - Cineloop review with full playback control - Trackball controlled color region of interest, size and position - DRS control for spatial resolution and penetration 9. Contrast Specific Imaging (CSI) or Dynamic Contrast imaging or Contrast imaging function or Contrast Imaging - System optimized for detecting contrast agent signatures as they are approved for use - Ioptimize one -button patient optimization control and Dynamic Resolution System turned specifically during contrast studies 10. Tissue Harmonic Imaging(THI) or Dynamic Tissue Harmonic Imaging(dTHI) or Differential Tissue Harmonic technology or Tissue Harmonic imaging - Patented pulse inversion phase cancellation technology - System processing of second harmonic frequencies in Tissue

3 11. Tissue Harmonic SonoCT Imaging or dthi with HI Com or THI with Aplipure or issue Harmonic imaging with SuperCompound - Patented pulse inversion phase cancellation technology - System processing of second harmonic frequencies in Tissue - Supports SonoCT Imaging - Vascular Enhancement 12. Color Power Angio Imaging(CPA) or Color Flow Angiography or Advanced Dynamic Flow or Color & Power doppler - High sensitive mode for small vessel visualization 13. Measurement Tools and General Description - 2D distance - 2D circumference/ area by ellipse, continuous trace, trace by points - 2D curved-linear distance - Manual Doppler distance and trace - High Q Automatic Doppler Analysis or Auto Doppler - Doppler values including PI,RI,S/D indices - 2-D volume 14. Cineloop Review - Acquisition, storage in memory and display in real-time and duplex Modes of up to 2,200 frames or more 15. ISCAN with AGC or Patient Dependent Correction(PDC) or Q-scan or Auto TGC - One - touch image optimization 2D and Doppler - Available on all imaging transducers - Operation in conjunction with SonoCT and XRES imaging - Adaptive Gain Compensation (AGC) 16. IFOCUS Intelligent Focusing technology or Transmitting &Receiving focus or SmartFocus - Automatic computation of beam characteristics for selected region of interest - Provides best detail resolution and tissue uniformity for selected area - Eliminates need for traditional focus controls 17. IOPTIMIZE Intelligent Optimization or HI Support or Q-box - Multiple technologies for one-button approach to automatically and instantly adapt system performance for different patient size flow states and clinical requirements - Tissue Specific Imaging - Patient Optimization - Dynamic Resolution System (DRS) 18. SonoCT Real-time Compound Imaging or HI COM Real-time Image Compounding or ApliPure Realtime compounding or SuperCompound

4 - Available on all transducers except phased arrays - Automatic selection of the number of steering angles based on the user - select Res/Speed condition - Up to 9 lines of sight - automatically adjusted via DRS control - Operation in conjunction with XRES imaging 19. XRES Adaptive Image Processing or HI REZ+ Real-time tissue adaptive filter or ApliPure+ or SuperRes - Available on all transducers - Operation in conjunction with SonoCT imaging - MRI Imaging technology - Enhance tissue continuity 20. Panoramic Image or Wide View panoramic Imaging or Panoramic View or Panoramic Image 21. Elastography or Real-time Tissue Elastography or MicroPure ElastoQ or ShearWave Elastography 22. Tissue Aberration Correction or HI VUE circuitry for streamlined operation and signal flow or precision imaging or TissueTuner - Reduces the effect of acoustic beam distortion and sharpens spatial resolution on obese and technically challenging patients. 23. DATA Intelligent Management or Safe and Efficient Patient Data Interfacing - On-board workstation-class data management with thumbnail previews and storage of images, loops, and reports - Three internal hard drives separate system file, patient data storage and spooling data - Reprospective and prospective clip capture to internal drive or removable media - Integrated DVD/CD burning capability for storage of DICOM images or export in JPEG and avi for PC compatibility - DICOM 3.0 Print and Store capability to internal drive or DVD/CD - Selectable compression for jpg and DICOM loop transfer - Support for transfer of exam report measurement data via USB Connection to various third party database programs 24. Connectivity or Network interface - Standard connectivity features or similar 1) DICOM Print 2) Image and Waveform export to removable media(dvd/cd) 3) Export of report data to off-line analysis computer programs 4) 100 base-t Ethernet output - NetLink Connectivity Option or similar 1) Image and waveform export to network storage servers 2) DICOM Worklist with RIS support and automatic patient demographic entry

5 3) Performed Procedure Step(PPS) 4) Storage Commit(SC) 5) Structured Reporting(SR) includes OB/GYN and vascular - DiskLInk-DVD or similar 1) The system supports standards DVD and CD media, and allows the following capabilities: - Read and Write(once) to CD(CD+R) - DVD Read + Write(DVD + RW) 2) Data storage formats include DICOM, JPEG and AVI for motion clips 3) User selectable compression is available for motion clip storage 4) DICOM images stored on disc can be recalled on the ultrasound system 5) JPEG images and AVI clips can be recalled on off-line viewing stations - On-board Patient Exam Storage or similar 1) Direct digital storage of B/W and color loops to internal hard Disk drives 2) Combined 160 GB storage capacity 3) Storage capacity of approximately 350 patient exam 25. Power supply requirement : 220V/60Hz

6 B. CONFIGURATION : Choice A or B or C or D Choice A 1. Main Console System(iU-22) 1system - xstream system architecture - Broadband acoustic beamforming - 57,000 digital channels db dynamic range - 1TB hard disk drive - integrated CD/DVD 2. Imaging Modes 1set -2D grayscale imaging with advanced pulse coding, pulse sharping, -Multivariate Tissue Harmonic Imaging -Tissue aberration correction -Coded beamforming with chirp transmit -Next Generation SonoCT beam-steered real-time compounding imaing -Harmonic sonoct imaging -Next Generation XRES adaptive image processing technology -ISCAN intelligent scanning with one- button TGC, gain and compression map optimization -Broadband flow imaging -Philips Color Power Angio Imaging(CPA) -Color compare mode -Freehand 3D and MPR imaging -Contrst imaging 3. Adaptive Broadband Flow Imaging 1set 4. Contrast Specific Imaging 1set 5. Tissue Harmonic Imaging 1set 6. Color Power Angio Imaging 1set 7. Freehand 3D volume and MPR imaging 1set 8. ISCAN Intelligent with AGC 1set 9. IFOCUS Intelligent Focusing technology 1set 10. IOPTIMIZE Intelligent Optimization 1set 11. SonoCT Real-time Compounding Imaging 1set 12. X-RES Adaptive Imagine Processing 1set 13. Advance Breast Package 1set 14. Tissue Aberration Correction 1set 15. Intima Media Thickness(IMT) Quantification 1set 16. Elastography 1set 17. Elasto-Quantification(EQ) 1set

7 18. DATA Intelligent Management 1set 19. DICOM Connectivity 1set 20. Clinical S/W 1set 21. C5-1 Broadband Purewave Crystal Transducer 1set 22. L12-5 Broadband Linear Array Transducer 1set 23. C8-5 Broadband Curved Array Transducer 1set 24. L9-5ec Broadband Curved Array Transducer 1set 25. Operation Manual & Service Manual each 1book

8 B. CONFIGURATION : Choice A or B or C or D Choice B 1. Main Console System(Prosound F75) 1system - Full Aperture Apodization (Faa) - Cpwg (Compound Pulse Wave Generator) Programmable Waveform Transmission - Multi Processing High-Speed Digital Beam Former 12-Bit A/D Converter (4096 Gray Levels) - Delay Precision : 1/64 At Minimum In Both - Transmission : Multi-Stage Transmission Focus Of Up To 4 Stages Out Of 16 Stages - Reception : Pixel Focus - Compound Dual Focusing (When Compound Array Probe Is Connected) - Beam Signal Processing : Dynamic 4D Apodization - Hemispheric Sound Technology Probe - The (Tissue Harmonic Echo) Imaging Module - Data Dynamic Display - Multifrequency Electronic Convex/Linear Connector Module - Adaptive Imaging Processing - Continuous Dynamic Frequency Scanning Module - Directional E-Flow - Full Key Board With Variable Software Program - Very Precise Focus Control (Pixel Focusing) - Harmonic Compounding - Quint Frequency Imaging - Probe Connectors :Electronic Scanning Probes: 4, Independent Probes : 1(Option) - Big Capacity Digital Scan Converter - Computerized Measuring And Calculating Function - Trackball Unit With Zoom Function - Pw, Hprf-Pw, Cw Doppler Module Option - Cine Image Memory Module Option - Color Flow Mapping Module Inch Tft Lcd Touch Panel - 19-Inch Wsxga Display Tilt And Swivel Are Possible Height Adjustment And Swivel Together With Operation Panel

9 2. Data Management System (DMS) 1) Image Data - Format : Multiple-Frame (Moving) Image ; Line Data (Dicom) Single-Frame(Still) Image ; Dicom (Pallet, Rgb, Jpeg) Tiff, Bmp, Jpeg - Image Acquisition Mode ; Real-Time Multi-Frame Image Acquisition Cine Loop High-Speed Data Transfer Multiple Media Simultaneous Output - Image Data Management Tool : Image Viewer ; Thumbnail Display Of Stored Images Image Zoom, Rotation, Inversion 1:1 Replay (Main Unit Hdd Or Dicom Storage Data) Cd-R Writing Re-Storing To Media, Transfer 2) Measurement Data - It Is Possible To Store Measurement Data In The Main Unit Hard Disk 3) Patient Data - Displayed Information Patient Information : Id (Up To 64 Char- Acters), Name (Up To 64 Characters, Including Middle Name), Birthday, Sex Study Information : Study Id, Age, Height Weight, Accession, Referring Physician, Study Description, Operator Series Information : Application 4) Data Storage Media - Main Unit Hard Disk Usable Space : Up To About 120Gb - Floppy Disk, Mo Disk, Cd-R, Usb - Network Interface : 10 Base/T Or 100 Base/Tx (Automatically Switched)

10 5) Dicom Network Communication(SOP-F75-10) - Conformity To Dicom Service Class : Ultrasound Image Storage Scu Ultrasound Multi-Image Storage Scu Storage Medial Fsc/Fsr Print Management Scu Modality Worklist Management Scu - Storage : Store Patient Information Directly To Dicom File Server - Printer : Printout Images With Dicom Compatible Printer Directly - Work List Managemtn : Retrieval Of Patient And Reservation Information Form Hospital Information System - Router Setting : Possible 6) Real-Time Tissue Elastography(SOP-F75-43) - This Function Is Used To Visualize The Stiffness Of A Tissue In Real-Time. The Strain Generated In A Tissue On Applying Pressure Is Represented By Colors: Stiffer Areas(Areas Of Smaller Deformation) Are Shown In Blue 7) Automated IMT Measurement(SOP-F75-38) 3. Electronic Convex Probe(UST-9147) 1set 4. Electronic Linear Probe(UST-5415) 1set 5. Electronic Linear Probe(UST-567) 1set 6. Electronic Linear Probe(UST-675P) 1set 7. Operation / Service Manual each 1book

11 B. CONFIGURATION : Choice A or B or C or D Choice C 1. Main Console System(LOGIQ E9) 1system 2. Imaging Modes 1set 3. CrossXbeam(Spactial Compounding) 1set 4. SRI-HD(Speckle Reduction Imaging) 1set 5. Raw Data Analysis 1set 6. Coded Harmonic Imaging(CHI) 1set 7. Advanced 3D 1set 8. Automatic Optimization(AO) 1set 9. Anatomical M-mode 1set 10. Accumulation Mode 1set 11. Measurements & Calculations Package 1set 12. Virtual Convex 1set 13. Fine Angle Steer 1set 14. Built in Gel warmer 1set 15. Matrix Transducer(Voxel Image Processing) 1set 16. Auto IMT 1set 17. Elastography for Breast & Quanfification Analysis 1set 18. DICOM 3.0T 1set 19. C1-5-D Convex Probe 1set 20. ML6-15-D Matrix Array Linear Probe 1set 21. S4-10 Sector Transducer 1set 22. IC5-9-D Endorectal Probe 1set 23. Operation Manual & Service Manual each 1book

12 B. CONFIGURATION : Choice A or B or C or D Choice D 1. Main Console System(Aplio 500) 1system - Scan methods : Linear/Convex/Trapezoid/ - 19-inch, 1280 x 1024 High-Definition istyletm LCD Monitor inch High Resolution Color Touch Screen - Fully Programmable Controll Pannel with 6 Transducer Holder : Up/Down/Swivel - Transducer Connector : Active*4, Parking*2 - Scan Mode : B-mode/M-mode/Spectrum Doppler/Color Doppler/Power - Tissue Harmonic Imaging - External I/O: VHS, S-VHS, SVGA, Ethernet, Audio, USB*2 - B/M/PW/Cardiac/OB/GYN/Vascular/Measurement Package - Cine Memory (Max. 4,095 frames) - Recording Functions : Internal HDD, Internal DVD/CD drive, USB Device - Supported file formats : DICOM,JPEG, TIFF, BMP, AVI, MPEG-4, WMV 2. General Information 1set 3. System 1set 4. B-mode 1set 5. M-mode 1set 6. Spectrum Doppler 1set 7. Color Doppler 1set 8. ASQ 1set 9. MicroPure 1set 10. Elastography 1set 11. Advanced Dynamic Flow(ADF) 1set 12. Trapezoid scan 1set 13. THI (Tissue Harmonic Imaging) 1set 14. D-THI 1set 15. ApliPure (Receive Compound Imaging) 1set 16. ApliPure Plus (Transmit Compound Imaging) 1set 17. Precision Imaging 1set 18. Speckle Reductio(SR) 1set 19. Tissue Specific Optimazation(TSO) 1set 20. Quick Scan 1set 21. Auto-IMT 1set 22. Measurement functions 1set 23. Cine memory (mass-storage image memory) 1set

13 24. Storage & Archiving 1set 25. DICOM 1set MHz Linear Transducer(PLT-805AT) 1set MHz Convex Transducer(PVT-375BT) 1set MHz Convex Transducer(PVT-712BT) 1set MHz Linear Transducer(PLT-1204BT) 1set 30. Operation / Service Manual each 1book

14 C. REMARK : 1. 장비보증기간은장비도입완료보고서기술 ( 인수 ) 검수완료일로부터 3년간으로한다. 1 보증기간중장비물품대 (Main System, Transdusducer, OEM Device 등포함 ) 및인건비는전액무상으로한다. 2 3년간무상보증종료후장비소모성부품은입찰및계약시 List 근거자료를제출하여야실비로인정하고 3년간무상보증종료후유상수리시인건비는전액무상으로하고부품비만인정한다. 3 본원 Spec 기능미달, Consist of 구성품미납시본원의료기공급및설치계약서의 ( 계약목적물 ) 계약금액으로지체상금을지불한다. 4 Ultrasound System 을정상적으로활용할수있도록예방정비를정규근무시간중에합의된일정표에의거분기1회정기적으로실시한후점검기록표를사용부서장확인후 1부를병원에제출하여야한다. 2. Ultrasound System 공급자는향후본원 PACS System을연결할경우양방향 Dicom 3.0 Image 전송및 Worklist 지원이되도록 Interface 시켜야하고 In-Out 에필요한모든부품및기타품목을장비공급회사에서공급하고 Cable 및 Cable 보호용자바라작업을기술부서 ( 의료장비파트 ) 와협의하여설치완료하여야한다. 1 Ultrasound System은별도의 Module 을추가하지않고장비자체에서 Dicom 3.0 Format 을완벽하게지원해야한다. 2 향후 PACS와연동을위한 Worklist 지원은본원 OCS상의정보를완벽하게지원해야한다. 3. Ultrasound System 공급자는설치장소에공급자가운반및설치완료시키고설치에따른부대비용 ( 장비운반도비비용, 크레인또는지게차비용, 전기분전함이후전원공사등 ) 은공급자부담으로하며사용자가원활하게사용할수있도록운영시험및교육을시킨후납품으로인정한다.( 단. 모든설치는사용부서 ( 용인세브란스병원영상의학과 ), 기술부서 ( 의료장비파트 ) 와협의하여확정된안으로설치한다.) 4. 입찰서기입시 3년무상 A/S 만료후의 Transducer Price 가격제시한다. 5. 의료장비조립설치후 Packing Box 및발생되는잔여물은장비공급회사책임하에처리한다. 6. FIRM OFFER, 수입면장및수입신고서별첨용지에 Operation Manual and Service Manual을기재하고원본 manual을공급해야한다. 7. 기술및사용부서에서서비스요청시 24시간이내병원현장도착및수리에임하는것을원칙으로한다. 결 담당자부서장신청부서장 제

DC-6. Diagnostic Ultrasound System

DC-6. Diagnostic Ultrasound System DC-6 Diagnostic Ultrasound System DC-6 is a general purpose color Doppler ultrasound system aiming at most clinical areas both in exam and research with various transducers and multi software packages

More information

DC-6 Expert. Diagnostic Ultrasound System

DC-6 Expert. Diagnostic Ultrasound System DC-6 Expert Diagnostic Ultrasound System MINDRAY has newly released DC-6 Expert, a general purpose color Doppler ultrasound system with full ergonomic designs, supplying more accessible exams, higher imaging

More information

: PT Philips Indonesia CERTIFICATE OF PRODUCTION SOLE AGENT/ DISTRIBUTOR : NA CERTIFICATE OF DISTRIBUTION (PAK)

: PT Philips Indonesia CERTIFICATE OF PRODUCTION SOLE AGENT/ DISTRIBUTOR : NA CERTIFICATE OF DISTRIBUTION (PAK) SOLE AGENT/ DISTRIBUTOR : PT Philips Indonesia CERTIFICATE OF PRODUCTION : NA CERTIFICATE OF DISTRIBUTION (PAK) : HK.07.Alkes/IV/625/AK.2.2012 ADDRESS : Jl. Buncit Raya Kav 99-100, Pasar Minggu, Jak-Sel

More information

Quick Reference Guide

Quick Reference Guide siemens.com/nx3 Quick Reference Guide ACUSON NX3 Series Contents 2 System Overview 3 Getting Started 8 2D Mode and M-mode 12 Color and Spectral Doppler 24 Measurements and Calculations 38 Text, Arrows

More information

M5 Diagnostic Ultrasound System

M5 Diagnostic Ultrasound System V0807 M5 Diagnostic Ultrasound System Mindray s ultrasound family is now introducing a new member, M5 hand-carried color Doppler system. M5, coming in a laptop size with comprehensive ergonomic design,

More information

S S S2 Operation Manual

S S S2 Operation Manual PREPARATION 1. How to create and input patient data? In the MAIN INTERFACE, press the key, to enter into the patient exam list interface. Then, click New patient item to create new patient files. Patient

More information

Vivid i Ultra-Portable Echo System

Vivid i Ultra-Portable Echo System Vivid i Ultra-Portable Echo System Product Description The Vivid i is a high-performance, battery-operated, ultra-portable diagnostic Ultrasound systems providing premium image quality. The Vivid i is

More information

UGEO H60. Performance in Style. Features

UGEO H60. Performance in Style. Features UGEO H60 Performance in Style The UGEO H60 implements superior performance with new design principles of simplicity and lightness. Its 10.1" touchscreen improves usability while its 18.5" LED monitor enhances

More information

GE Healthcare LOGIQ P3. Staying ahead of the curve

GE Healthcare LOGIQ P3. Staying ahead of the curve GE Healthcare LOGIQ P3 Staying ahead of the curve Ultrasound Expertise. Enhanced. GE is a trusted partner of many healthcare providers around the world. GE s TruScan technology, incorporating SmartScan,

More information

Multipurpose Color Ultrasound System IMAGING SYSTEMS

Multipurpose Color Ultrasound System IMAGING SYSTEMS i3 Multipurpose Color Ultrasound System IMAGING SYSTEMS IMAGING SYSTEMS i3 Color Ultrasound System M The revolutionary i3 provides you outstanding 2D images and fast 4D volume images, while the streamlined

More information

Design Your Performance

Design Your Performance MEDISON has been a leading name in diagnostic ultrasound since its foundation in 1985. As one of the only companies dedicated solely to ultrasound imaging, we have remained at the forefront of research

More information

M 5. M5 Hand-carried Diagnostic Ultrasound System. Mindray. A practical, durable ultrasound tool for high-quality imaging where and when you need it.

M 5. M5 Hand-carried Diagnostic Ultrasound System. Mindray. A practical, durable ultrasound tool for high-quality imaging where and when you need it. M 5 Mindray M5 Hand-carried Diagnostic Ultrasound System A practical, durable ultrasound tool for high-quality imaging where and when you need it. Affordable, easy-to-use ultrasound for precision and confidence

More information

Diagnostic Ultrasound System. Operation Note

Diagnostic Ultrasound System. Operation Note M5 Diagnostic Ultrasound System Table of Contents System Introduction...3 Control Panel...4 Control Panel...5 Control Panel...6 Control Panel...7 Control Panel...8 Control Panel...9 Power ON / OFF the

More information

Quality Ultrasound Systems

Quality Ultrasound Systems Quality P11VExpert Medisono offers quality products to the medical imaging market. We offer different solutions tailored to the needs of each patient, offering the best value to every single patient. We

More information

SONOACE 6000C MT DIGITAL COLOR. Affordable PC-based Digital CFM Ultrasound System. Specifications.

SONOACE 6000C MT DIGITAL COLOR. Affordable PC-based Digital CFM Ultrasound System. Specifications. Specifications Imaging Modes Gray Scale Focusing PC Monitor Speaker Measurements Image Processing Display Functions Peripheral Devices Support Physical Dimensions Electrical Parameters Probe Types Single

More information

Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare

Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare 2 DOC1292532 Architecture of Quality Imaging Agile Acoustic Architecture E-Series and XDclear

More information

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS DRive is a digital imaging DR hardware & Software solution designed for General Radiography of anatomy. It intended to replace film/screen

More information

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions. Lesson 06: Pulse-echo Imaging and Display Modes These lessons contain 26 slides plus 15 multiple-choice questions. These lesson were derived from pages 26 through 32 in the textbook: ULTRASOUND IMAGING

More information

Excellent Performance; Ease of Use

Excellent Performance; Ease of Use Excellent Performance; Ease of Use High performance with a broad range of applications - the compact ProSound α6 is at your service. Our ProSound series has a well-established reputation in hospitals and

More information

Personal Ultrasound The future of ultrasonic scanning is here, today right in your hands. It s portable and affordable giving you the power and

Personal Ultrasound The future of ultrasonic scanning is here, today right in your hands. It s portable and affordable giving you the power and What the Laptop Did for PCs, MySono201 Does for Ultrasonic Scanning The Personal Digital Ultrasound, Only MySono201 Personal Ultrasound The future of ultrasonic scanning is here, today right in your hands.

More information

M7Vet Diagnostic Ultrasound System. Operation Note

M7Vet Diagnostic Ultrasound System. Operation Note M7Vet Diagnostic Ultrasound System Operation Note Table of Contents Table of Contents... i 1 System Introduction... 1 2 Control Panel... 2 3 Icons on the Screens... 6 4 Power ON/ OFF... 7 5 Enter or Search

More information

Vivid 7 Pro Breakthrough 2008 Release

Vivid 7 Pro Breakthrough 2008 Release Vivid 7 Pro Breakthrough 2008 Release Product Description The Vivid 7 Pro is a complete digital color flow Doppler ultrasound system providing a wide range of premium performance applications in cardiac,

More information

Printed in Japan E318

Printed in Japan E318 Diagnostic Ultrasound System MODEL PROSOUND 6 The specifications, shape and color of this product are subject to change without notice. The standard components and optional items vary depending on the

More information

www.hitachi-aloka.com Revolutionary Performance; Ease of Use The ProSound 6 is the next generation of compact color ultrasound systems, providing unprecedented performance with a broad range of applications.

More information

Product Description. System Architecture. Display Formats. Data Acquisition. Display Annotations. Data Processing. Display Screen

Product Description. System Architecture. Display Formats. Data Acquisition. Display Annotations. Data Processing. Display Screen Vivid i n Product Description The Vivid i n is a high-performance, battery-operated, ultra-portable diagnostic Ultrasound systems providing exceptional image quality. The Vivid i n is designed for cardiovascular

More information

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments. Choose the FCR system that best fits your practice. The FCR XL-2. Perfect for higher-volume environments. It can process up to 94 images per hour yet it fits right into small exam rooms or offices where

More information

Beyond Performance and Value

Beyond Performance and Value Putting the back in ultrasound Beyond Performance and Value Esaote s new ultra-performance MyLab 9 exp ultrasound system is designed to support a full range of shared service diagnostic imaging environments.

More information

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl Ultrasound Beamforming and Image Formation Jeremy J. Dahl Overview Ultrasound Concepts Beamforming Image Formation Absorption and TGC Advanced Beamforming Techniques Synthetic Receive Aperture Parallel

More information

KIZLON. Sentinel House,Harvest Crescent, Ancells Business Park, Fleet Hampshire GU51 2UZ, UK Website:

KIZLON. Sentinel House,Harvest Crescent, Ancells Business Park, Fleet Hampshire GU51 2UZ, UK   Website: KIZLON Sentinel House,Harvest Crescent, Ancells Business Park, Fleet Hampshire GU51 2UZ, UK Email: info@kizlon.com Website: www.kizlon.com Portable Ultrasound Scanners KUS-A100 & A101 Ultrasound Scanners

More information

Endoscopic Ultrasonography System

Endoscopic Ultrasonography System Endoscopic Ultrasonic Processor SU- -H-, SU- -S- Power rating Power supply rating Current consumption(rated) Dimensions Size Weight Ultrasonography Probe types image display Scanning modes Special modes*

More information

EVIS EUS ENDOSCOPIC ULTRASOUND CENTER EU-ME2 Dedicated ultrasound processor with versatile functionality.

EVIS EUS ENDOSCOPIC ULTRASOUND CENTER EU-ME2 Dedicated ultrasound processor with versatile functionality. EVIS EUS ENDOSCOPIC ULTRASOUND CENTER EU-ME2 Dedicated ultrasound processor with versatile functionality. Advancing the Art of Endosonography The EU-ME2 is a high-quality compact ultrasound processor for

More information

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System ECORAY Co., LTD. 3F, Urbanlight B/D, 630, Eonju-ro, Gangnam-gu, Seoul, Korea 135-832 Factory at 621-14, Dochun-dong, Gwangsan-gu, Gwangju, Korea 506-301 TEL. : +82-70-7510-3400 FAX. : +82-70-8630-3420

More information

Solutions Page Content ImagePilot. Primary keywords: Digital radiography Computed radiography Image viewing and storage

Solutions Page Content ImagePilot. Primary keywords: Digital radiography Computed radiography Image viewing and storage Solutions Page Content Primary keywords: Digital radiography Computed radiography Image viewing and storage Solution Description For facilities with medium volume imaging, Konica Minolta s original all-in-one

More information

Grubstr- 6-8 D Vörstetten Tel.: +49(0) Fax: +49(0) Steinhart Medizinsysteme GmbH

Grubstr- 6-8 D Vörstetten Tel.: +49(0) Fax: +49(0) Steinhart Medizinsysteme GmbH Hipax Diagnostic Workstation Table of Contents 1. PRODUCT DESCRIPTION... 2 2. HIPAX DW MODULES... 2 2.1 DW BASE MODULE... 2 2.1.1 DW BASE MODULE STANDARD (05-010)... 2 2.1.2 DW BASE MODULE LIGHT (05-020)...

More information

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System Co., LTD. 3F, Urbanlight B/D, 630, Eonju-ro, Gangnam-gu, Seoul, Korea 135-832 Factory at 621-14, Dochun-dong, Gwangsan-gu, Gwangju, Korea 506-301 TEL. : +82-70-7510-3400 FAX. : +82-70-8630-3420 sales@ecoray.kr

More information

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming Ultrasound Bioinstrumentation Topic 2 (lecture 3) Beamforming Angular Spectrum 2D Fourier transform of aperture Angular spectrum Propagation of Angular Spectrum Propagation as a Linear Spatial Filter Free

More information

Optimisation of Image Acquisition Bordeaux 16th November J.S. McGhie W.B. Vletter R. Frowijn No disclosures

Optimisation of Image Acquisition Bordeaux 16th November J.S. McGhie W.B. Vletter R. Frowijn No disclosures Optimisation of Image Acquisition Bordeaux 16th November 2016 J.S. McGhie W.B. Vletter R. Frowijn No disclosures Image optimisation: The Echo machine It looks difficult to drive an echo machine!! Some

More information

SmartRAD. Advanced Digital Radiography System

SmartRAD. Advanced Digital Radiography System SmartRAD Advanced Digital Radiography System SmartRAD Expanding The Horizons Of Digital Radiography CMT introduces the SmartRAD Digital Radiography system, featuring an integrated flat panel digital detector

More information

FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice.

FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice. F U J I F I L M D I G I T A L X - R A Y FCR XL-2 and FCR XC-2. High-quality digital x-ray that's perfect for your private practice. So small, yet so powerful. With a compact footprint of less than 2.5

More information

A COMPACT SYSTEM WITH ADVANCED PERFORMANCE

A COMPACT SYSTEM WITH ADVANCED PERFORMANCE Samsung Medison is a global leading medical devices company. Founded in 1985, the company sells cutting-edge diagnostic ultrasound devices around the world in various medical fields. The company has attracted

More information

4 Working With Scan Modes

4 Working With Scan Modes 4 Working With Scan Modes Scan Modes Overview All of the information in this chapter pertains to live imaging. Many of the controls and functions change when you freeze the scan. For information on using

More information

Product Description. Display Screen. System Architecture. Display Formats. Data Acquisition. Display Annotations. Data Processing

Product Description. Display Screen. System Architecture. Display Formats. Data Acquisition. Display Annotations. Data Processing Vivid * i BT12 Product Description The Vivid i is a high-performance, battery-operated, ultra-portable diagnostic Ultrasound systems providing exceptional image quality. The Vivid i is designed for cardiovascular

More information

Discover the new Prestige and experience 3D/4D imaging beyond your imagination.

Discover the new Prestige and experience 3D/4D imaging beyond your imagination. 3D/4D Beyond Imagination The Prestige ultrasound imaging system represents the pinnacle of more than a decade of technological advancement in 3D/4D ultrasound imaging at MEDISON. Inheriting a tradition

More information

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust The physics of ultrasound Dr Graeme Taylor Guy s & St Thomas NHS Trust Physics & Instrumentation Modern ultrasound equipment is continually evolving This talk will cover the basics What will be covered?

More information

ZView ver.2 DR Console Software. User Manual. (for HUMAN) Manual Version : 2.1 Revision : 002

ZView ver.2 DR Console Software. User Manual. (for HUMAN) Manual Version : 2.1 Revision : 002 ver.2 DR Console Software User Manual (for HUMAN) Manual Version : 2.1 Revision : 002 Table of Contents 1. Introduction... 4 2. Purpose... 4 3. System requirements... 5 3-1. Workstation... 5 3-2. Monitor...

More information

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions. Lesson 06: Pulse-echo Imaging and Display Modes This lesson contains 22 slides plus 15 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 26 through 32 in

More information

ENDOSCOPIC ULTRASOUND SYSTEMS

ENDOSCOPIC ULTRASOUND SYSTEMS ENDOSCOPIC ULTRASOUND SYSTEMS DISCOVER HIGH-PRECISION DIAGNOSES AND PROCEDURES NEW ENDOSCOPIC ULTRASOUND Ultrasonography revolutionized the clinical approach to patients with digestive and respiratory

More information

DIAGNOSTIC SCANNER HS-1600V. Convex/Linear Ultrasonic System

DIAGNOSTIC SCANNER HS-1600V. Convex/Linear Ultrasonic System HONDA ELECTRONICS CO.,LTD. DIAGNOSTIC SCANNER Convex/Linear Ultrasonic System HS-1600V Our unique technology is the product of our originality and continual pursuance of achieving high quality. It is also

More information

Multi-Access Biplane Lab

Multi-Access Biplane Lab Multi-Access Biplane Lab Advanced technolo gies deliver optimized biplane imaging Designed in concert with leading physicians, the Infinix VF-i/BP provides advanced, versatile patient access to meet the

More information

The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line

The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line AV-9100 Single Channel ECG 1 2 AV-9300 3-Channels ECG 3 4 5 AV-9000B Multi-Parameter Patient Monitor 6 7 8 AV-9000C

More information

CR30-ORACLE CR. with Office Viewer. A Revelation in Computed Radiography. Innovations in Digital Imaging. Solution for Quantum Medical Imaging

CR30-ORACLE CR. with Office Viewer. A Revelation in Computed Radiography. Innovations in Digital Imaging. Solution for Quantum Medical Imaging CR30-ORACLE CR with Office Viewer A Revelation in Computed Radiography Innovations in Digital Imaging Solution for Quantum Medical Imaging CR30-ORACLE CR with Office Viewer The CR30-ORACLE CR System Package

More information

Ultrasound physical principles in today s technology

Ultrasound physical principles in today s technology Education Ultrasound physical principles in today s technology Brian Starkoff M.App.Sc.(Med. Ultrasound), AMS Holland Park Brisbane Queensland Australia Correspondence to email starkoff@optusnet.com.au

More information

Get more from your images with Symphony Image Processing

Get more from your images with Symphony Image Processing DIRECT RADIOGRAPHY The user-friendly DelWorks image acquisition and processing software provides a wide range of tools for a variety of image enhancements. Its user interface simplifies every step of the

More information

Resona 6 Premium Ultrasound System

Resona 6 Premium Ultrasound System The system Resona 6 is the newly developed, unique result of the mergence of leading companies Mindray Bio-medical Electronics Co. Ltd. and ZONARE Medical Systems, Inc.. By additions to the core competencies

More information

The Versatile and Powerful ACLxy. ACLxy

The Versatile and Powerful ACLxy. ACLxy The Versatile and Powerful ACLxy ACLxy Rolling into a Clinic, Imaging Center and Hospital Near You! COMPUTED RADIOGRAPHY (CR) IS RAPIDLY THE BEGINNING. THE OREX CR SOLUTION DRA- BECOMING A DRIVING FORCE

More information

PACS Fundamentals. By: Eng. Valentino T. Mvanga Ministry of Health and Social Welfare Tanzania

PACS Fundamentals. By: Eng. Valentino T. Mvanga Ministry of Health and Social Welfare Tanzania PACS Fundamentals By: Eng. Valentino T. Mvanga Ministry of Health and Social Welfare Tanzania 1 Learning Goals To Understand the importance of PACS To Understand PACS infrastructure requirement Introduction

More information

GE Healthcare. Senographe 2000D Full-field digital mammography system

GE Healthcare. Senographe 2000D Full-field digital mammography system GE Healthcare Senographe 2000D Full-field digital mammography system Digital has arrived. The Senographe 2000D Full-Field Digital Mammography (FFDM) system gives you a unique competitive advantage. That

More information

CR35-SP+ Computed Radiography (CR) System. Innovations in Digital Imaging

CR35-SP+ Computed Radiography (CR) System. Innovations in Digital Imaging CR35-SP+ Computed Radiography (CR) System Innovations in Digital Imaging Solution for Quantum Medical Imaging CR35-SP+ Package An Agfa Healthcare Solution for Quantum Medical Imaging The CR35-SP+ Package

More information

Introduction to Ultrasound Physics

Introduction to Ultrasound Physics Introduction to Ultrasound Physics Vassilis Sboros Medical Physics and Cardiovascular Sciences University of Edinburgh Transverse waves Water remains in position Disturbance traverse producing more wave

More information

Touch Screen Technology. Classic WAIV. with Touch Screen Technology. Legendary Reputation...Sensitivity to your budget

Touch Screen Technology. Classic WAIV. with Touch Screen Technology. Legendary Reputation...Sensitivity to your budget Touch Screen Technology Classic WAIV with Touch Screen Technology Legendary Reputation...Sensitivity to your budget Streamline Workflow For Higher Productivity And Patient Throughput. The CRescendo Classic

More information

Cutting-edge image quality

Cutting-edge image quality ENGLISH Cutting-edge image quality The innovative Planmeca ProSensor intraoral sensor sets new standards for imaging in dental practice. Planmeca ProSensor is a unique combination of high-end patient-centred

More information

Model: ESE-6 Portable Color Ultrasound System

Model: ESE-6 Portable Color Ultrasound System DATA SHEET Model: ESE-6 Portable Color Ultrasound System Ultrasound System Specifications The premium performance of the full functional Portable ESE-6 provides a fast and easy diagnosis by: Ultra-premium

More information

Philips XPER FD10C R7.0.4

Philips XPER FD10C R7.0.4 Philips XPER FD10C R7.0.4 Reconditioned 2005 System- Upgraded to R7 in Oct 2010 The Allura Xper FD10 (Ceiling) single-plane cardiovascular system is comprised of a ceiling mounted C-arm stand and digital

More information

Ultrasound System Specifications

Ultrasound System Specifications Ultrasound System Specifications The superb imaging and performance capabilities of VINNO G60 give you the confidence and efficiencies in your daily exam by: World class image quality with unmatched high-frequency

More information

See what you need to see, and see it anywhere.

See what you need to see, and see it anywhere. See what you need to see, and see it anywhere. Fujifilm Computed Radiography (FCR) that makes the best use of Fujifilm s unique image processing technology has become even more convenient. In addition

More information

C506-E064. Full digital system. Printed in Japan A-NS

C506-E064. Full digital system. Printed in Japan A-NS C506-E064 Full digital system Printed in Japan 6295-08807-30A-NS Full digital system Highest Image Quality in Its Class Comprehensive Full-Digital System FLEXAVISION is a full-digital R/F system equipped

More information

Get more from your images with Symphony Image Processing

Get more from your images with Symphony Image Processing DIRECT RADIOGRAPHY The user-friendly DelWorks image acquisition and processing software possesses a wide range of tools for a variety of image manipulations. Its user interface simplifies every step of

More information

Vivid S5. Cardiovascular ultrasound system. GE Healthcare. Davis Medical

Vivid S5. Cardiovascular ultrasound system. GE Healthcare. Davis Medical GE Healthcare Vivid S5 Cardiovascular ultrasound system Versatility. It s a new design concept one that leverages our miniaturization expertise gained from the Vivid i and our performance expertise of

More information

Vevo770 Ultrasound. Quick Operation Guide

Vevo770 Ultrasound. Quick Operation Guide Vevo770 Ultrasound Quick Operation Guide Vevo770 Probe head (707B) Preparation The acoustic membrane is very fragile and sensitive, it must be handled with care. Position the RMV scan head with the fill

More information

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound Ultrasound Physics History: Ultrasound Ultrasound 1942: Dr. Karl Theodore Dussik transmission ultrasound investigation of the brain 1949-51: Holmes and Howry subject submerged in water tank to achieve

More information

User Manual Veterinary

User Manual Veterinary Veterinary Acquisition and diagnostic software Doc No.: Rev 1.0.1 Aug 2013 Part No.: CR-FPM-04-022-EN-S 3DISC, FireCR, Quantor and the 3D Cube are trademarks of 3D Imaging & Simulations Corp, South Korea,

More information

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection Shantou Institute of Ultrasonic Instruments Co., Ltd. Add: 77 Jinsha Road, Shantou, Guangdong 515041, China Tel: 86-754-88250150 Fax: 86-754-88251499 Http://www.siui.com/ndt Product Data CTS-9009 Digital

More information

Examion. New. Image Acquisition and Diagnostics. R a d i o D i g i t a l e. examion aqs veterinray software.

Examion. New. Image Acquisition and Diagnostics. R a d i o D i g i t a l e. examion aqs veterinray software. Examion New V191303 V191304 V1913041 V191305 examion aqs veterinray software Image Acquisition and Diagnostics Z.I. de Noville-les-Bois 1 rue de la Tour (Bât. 31) B-5380 Fernelmont (Belgium) Tél. : +32

More information

Q5 VET. Compact, Affordable Color Doppler for VET

Q5 VET. Compact, Affordable Color Doppler for VET Q5 VET Compact, Affordable Color Doppler for VET Key Benefits Ergonomic design for learning easily, using efficiently Professional probes and software for veterinary Abundant image mode: B, 2B,4B,C,PW,M

More information

HIGH-RESOLUTION DIGITAL PHOTOSPOT SYSTEM years, CMT s technology is today proven in more than 4,500 clinical installations PRODUCT SPECIFICATION

HIGH-RESOLUTION DIGITAL PHOTOSPOT SYSTEM years, CMT s technology is today proven in more than 4,500 clinical installations PRODUCT SPECIFICATION CMT A Medical Imaging Leader SmartSPOT PrimaX RF CMT Medical Technologies is a market leader providing high-resolution digital X-ray imaging solutions for General Radiography, R&F rooms and Angiography

More information

CT-XGEO GC FTW EN

CT-XGEO GC FTW EN Samsung Electronics Co., Ltd. is a global leader in technology, opening new possibilities for people everywhere. Through relentless innovation and discovery, we are transforming the worlds of televisions,

More information

Introduction. Parametric Imaging. The Ultrasound Research Interface: A New Tool for Biomedical Investigations

Introduction. Parametric Imaging. The Ultrasound Research Interface: A New Tool for Biomedical Investigations The Ultrasound Research Interface: A New Tool for Biomedical Investigations Shelby Brunke, Laurent Pelissier, Kris Dickie, Jim Zagzebski, Tim Hall, Thaddeus Wilson Siemens Medical Systems, Issaquah WA

More information

ARCO Rk.5 Digital Mobile C-Arm

ARCO Rk.5 Digital Mobile C-Arm Product Data ARCO Rk.5 Digital Mobile C-Arm Product Data 1 Easy to move INTRODUCTION Designed with the latest technology throughout, the ARCO Rk.5 set new standards for the excellence image quality ease

More information

Ziehm Vision / Ziehm Vision FD The new standard in mobile imaging. > Flat-Panel Detector. > Image Intensifier

Ziehm Vision / Ziehm Vision FD The new standard in mobile imaging. > Flat-Panel Detector. > Image Intensifier 2 2 Ziehm Vision / Ziehm Vision FD The new standard in mobile imaging > Flat-Panel Detector > Image Intensifier 02 03 Ziehm Vision 2 18" TFT monitors provide bright, high contrast image with a wide viewing

More information

Portable Digital X-ray

Portable Digital X-ray Portable Digital X-ray Portable Digital X-ray Ideal choice for a complete range of radiographic procedure and eliminates the need for costly room modifications This is a complete outdoor X-ray system with

More information

Ultrasound System Specifications

Ultrasound System Specifications Ultrasound System Specifications Dedicated premium women healthcare ultrasound system VINNO M80 supports you in clinical decision-making and elevates trust in diagnostic confidence by: Premium image quality,

More information

TECHNICAL DATA. GIOTTO IMAGE SDL/W is pre-arranged for Full Field Digital Biopsy examination with the patient in prone position.

TECHNICAL DATA. GIOTTO IMAGE SDL/W is pre-arranged for Full Field Digital Biopsy examination with the patient in prone position. Ver. 01/06/07 TECHNICAL DATA GIOTTO IMAGE SDL/W LOW DOSE, FULL FIELD DIGITAL MAMMOGRAPHY UNIT USING AMORPHOUS SELENIUM (a-se) TECHNOLOGY DETECTOR (pre-arranged for stereotactic biopsy with the same digital

More information

Digital Radiography X-Ray System. X Twin with X Mobil Roesys GmbH [rshsmi] 1/11

Digital Radiography X-Ray System. X Twin with X Mobil Roesys GmbH [rshsmi] 1/11 Digital Radiography X-Ray System 2017 Roesys GmbH [rshsmi] 1/11 1 General specifications The system is intended to be installed with floor mounted components only. It enables spacesaving installation without

More information

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D DINFO Dipartimento di Ingegneria dell Informazione Department of Information Engineering Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D Piero Tortoli Microelectronics Systems Design Lab 1 Introduction

More information

Ultrasound System Specifications

Ultrasound System Specifications Ultrasound System Specifications Advanced women healthcare features and image quality VINNO M50 increases your clinical confidence for all obstetrical, gynecological and breast exams by Innovative, cutting-edge

More information

CD: (compact disc) A 4 3/4" disc used to store audio or visual images in digital form. This format is usually associated with audio information.

CD: (compact disc) A 4 3/4 disc used to store audio or visual images in digital form. This format is usually associated with audio information. Computer Art Vocabulary Bitmap: An image made up of individual pixels or tiles Blur: Softening an image, making it appear out of focus Brightness: The overall tonal value, light, or darkness of an image.

More information

QUICK GUIDE

QUICK GUIDE System Basics Chapter QUICK GUIDE 70002256 Rev. 0 (ENG) User Manual(E-CUBE 9) UG20100812 Rev.0 1 Chapter System Basics Copyright and License Reproduction, adaptation, or translation without prior written

More information

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY IIT Bombay requests quotations for a high frequency conducting-atomic Force Microscope (c-afm) instrument to be set up as a Central Facility for a wide range of experimental requirements. The instrument

More information

General Imaging Ultrasound in a Whole New Light. Introducing the

General Imaging Ultrasound in a Whole New Light. Introducing the General Imaging Ultrasound in a Whole New Light. Introducing the It s a Tour de Force Redefining innovation through value and performance It s the dawning of a new day in the world of compact ultrasound

More information

Answer: TGC is needed to amplify echoes from deeper structures so that they appear as bright as similar structures located at more shallow depths.

Answer: TGC is needed to amplify echoes from deeper structures so that they appear as bright as similar structures located at more shallow depths. Q47. When performing a sonogram why the sonographer needs to use the TGC? TGC is needed to amplify echoes from deeper structures so that they appear as bright as similar structures located at more shallow

More information

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING RADT 3463 - COMPUTERIZED IMAGING Section I: Chapter 1 RADT 3463 Computerized Imaging 1 SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT RADT 3463 COMPUTERIZED IMAGING Section I: Chapter

More information

Model: ESE-G50 Color Ultrasound System

Model: ESE-G50 Color Ultrasound System DATA SHEET Model: ESE-G50 Color Ultrasound System Ultrasound System Specifications Extremely portable and exceptional performance ESE-G50 meets all your clinical needs by: Unmatched image quality All ranges

More information

2 PLANMECA. PLANMECA ProSensor. ProSensor

2 PLANMECA. PLANMECA ProSensor. ProSensor NEW 10 YEAR Warranty Program! Cutting-Edge Image Quality The NEW innovative PlaNmEca Digital Intraoral system sets a new standard in dental X-ray imaging. With a unique combination of high-end patient-centered

More information

Parameter Estimation Techniques for Ultrasound Phase Reconstruction. Fatemeh Vakhshiteh Sept. 16, 2010

Parameter Estimation Techniques for Ultrasound Phase Reconstruction. Fatemeh Vakhshiteh Sept. 16, 2010 Parameter Estimation Techniques for Ultrasound Phase Reconstruction Fatemeh Vakhshiteh Sept. 16, 2010 Presentation Outline Motivation Thesis Objectives Background Simulation Quadrature Phase Measurement

More information

Classic Image Suite. Legendary Reputation...Sensitivity to your budget 'LYLVLRQ RI &DUHVWUHDP

Classic Image Suite. Legendary Reputation...Sensitivity to your budget 'LYLVLRQ RI &DUHVWUHDP Classic Image Suite Legendary Reputation...Sensitivity to your budget 'LYLVLRQ RI &DUHVWUHDP Classic Image Suite Simple, Affordable, Powerful A Complete Digital Image Acquisition and Management Solution

More information

DICOM Conformance Statement

DICOM Conformance Statement GE Medical Systems Kretz Ultrasound DICOM Conformance Statement 105952 Revision 0 VOLUSON 730Expert/Pro V. 4.0.x 0123 Copyright 2000, 2001, 2002, 2003, 2004 by GE Medical Systems Kretztechnik GmbH & Co

More information

PERFORM Operating Document. Use and Maintenance of G.E. Ultrasound LOGIQ E

PERFORM Operating Document. Use and Maintenance of G.E. Ultrasound LOGIQ E PERFORM Operating Document Use and Maintenance of G.E. Ultrasound LOGIQ E PC-POD-IM-001-v02 Revision History Version Reason for Revision Date 01 New POD 22/May/2013 02 Minor changes only 2.2 Change responsibility

More information

Performing ultrasound probe quality assurance assessments: A How-to Guide

Performing ultrasound probe quality assurance assessments: A How-to Guide Performing ultrasound probe quality assurance assessments: A How-to Guide A comprehensive quality assurance program has the potential to directly contribute to better patient outcomes. Regular testing

More information

DR Retrofit Kit Package Configuration Integrated PACS

DR Retrofit Kit Package Configuration Integrated PACS DR Retrofit Kit Package Configuration Integrated PACS Description: The DR Retrofit Kit - Configuration Integrated PACS makes the use of CR Cassettes/Imaging Plates or the use of analogue x-ray films, the

More information

Digital Image Management: the Basics

Digital Image Management: the Basics Digital Image Management: the Basics Napapong Pongnapang, Ph.D. Department of Radiological Technology Faculty of Medical Technology Mahidol University Outline From screen/film to digital radiography PACS/Tele

More information