The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line
|
|
- Gavin Glenn
- 5 years ago
- Views:
Transcription
1 The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line AV-9100 Single Channel ECG 1
2 2
3 AV Channels ECG 3
4 4
5 5
6 AV-9000B Multi-Parameter Patient Monitor 6
7 7
8 8
9 AV-9000C Multi-Parameter Patient Monitor 9
10 10
11 11
12 AV-9005 Multi-Parameter Maternal / Fetal Monitor 12
13 13
14 14
15 15
16 AV-2100 Splash Proof Mechanical Ultrasound Scanner APPLICATION RANGE This device is suitable in hospitals and clinics for diagnosing liver, GB, spleen, kidney, pancreas, heart, bladder, uterus. FEATURE SET This device uses micro computer technology, Digital Scanning Converter (DSC), variable aperture, multi-section dynamic focusing, high dynamic low noise and wide band preamplifier, log compression, TGC control, dynamic filtering, edge enhancement and frame correlation. The embedded components allow a clear, stable and high resolution image. Display modes: B, B+B, B+M, M; Gray scales: 256 levels. Real time scanning or picture freezing for analysis Splash proof sealed membrane keyboard Digital control of Gain, Contrast and Brightness (values display on LCD) Mouse for easy and convenient operation. Portable structured with plastic cover, 5 inch LCD, outside power supply. The use of integrated circuits makes this device one of the smallest and lightest of its kind in the world. 16
17 TECHNICAL SPECIFICATIONS Standard probe : 3.5MHz mechanical sector scanner Optional probe : 5MHz mechanical sector scanner straight or down fire Scanning depth : 192mm Detection depth: 140mm Lateral resolution : 3mm (depth 80mm) or 4mm (80mm < depth 130mm) Axial resolution : 2mm (depth 80mm) Dead zone : 8mm Geometric position precision (%) : Horizontal : 20 Vertical : 10 Monitor : TFT 5.0 inch LCD Battery capacity : 2200mAh, continuous working for 2 hours Display mode : B, B+B, B+M, M Image grey scale : 256 levels Image magnification : 1.0, 1.2, 1.5, 2.0 Measurement : distance, circumference, area, heart rate Characters input/display : patient s ID, age, sex Power consumption : 17VA Power supply : DC Adapter power : 45VA Weight : 600g Dimensions (L W H): 149mm 42mm 122mm Package content : scanner, probe, 1 battery, 1 AC/DC Adapter/Charger 110/220V AC 50/60Hz, mouse, English user's guide, ultrasound transmission gel bottle, metallic case. STANDARD COMPLIANCE This device is designed and manufactured by strictly complying with the following standards : National standard GB B Mode Ultrasound Diagnosis Equipment National standard GB Medical Electronic Equipment Part I: General Safety REQUIREMENT Band C, Type B Diagnosis equipment Class II, Type B Electronic shock protection Climate environment test group II Mechanical environment test group II of GB/T Environment Requirement and 17
18 Test Method for Medical Electronic Equipment ENVIRONMENT REQUIREMENTS Temperature : +5 C~+40 C Humidity : <80% Atmospheric pressure : 80kpa~106kpa Power supply : AC/DC Adapter/Charger 110/220V AC ±11/±22V 50/60Hz, Output: DC 10-12V MODEL B SCANNER PRINCIPLE Human organs are different in their densities and ultrasound speed, i.e. they have a different acoustic impedance. The piezoelectricity crystal (transducer) is excited by the electrical pulse to produce an ultrasound wave of definite frequency. This ultrasound wave is transmitted into the human body. The echo wave is made when the ultrasound wave passes through the surface of different organs. Echoes with different amplitudes are received via the same transmitting transducer. Received echoes (acoustic energy) are converted into electrical pulses which are amplified, demodulated and DSC, etc. A standard video signal is generated allowing the organ section image to be displayed on a monitor screen. 18
DIAGNOSTIC SCANNER HS-1600V. Convex/Linear Ultrasonic System
HONDA ELECTRONICS CO.,LTD. DIAGNOSTIC SCANNER Convex/Linear Ultrasonic System HS-1600V Our unique technology is the product of our originality and continual pursuance of achieving high quality. It is also
More informationLesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.
Lesson 06: Pulse-echo Imaging and Display Modes This lesson contains 22 slides plus 15 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 26 through 32 in
More informationKEE HING CHEUNG KEE CO., LTD. DLFTZ CHANG HING KEE INT L INDUSTRY & TRADE CO., LTD.
KEE HING CHEUNG KEE CO., LTD. DLFTZ CHANG HING KEE INT L INDUSTRY & TRADE CO., LTD. Ultrasound imaging system KHCK in the field of Medical Industry -------------- Medical imaging system Ultrasound imaging
More informationMedical Imaging (EL582/BE620/GA4426)
Medical Imaging (EL582/BE620/GA4426) Jonathan Mamou, PhD Riverside Research Lizzi Center for Biomedical Engineering New York, NY jmamou@riversideresearch.org On behalf of Prof. Daniel Turnbull Outline
More informationINTRODUCTION. Have applications for imaging, detection and navigation.
ULTRASONICS INTRODUCTION The word ultrasonic combines the Latin roots ultra - beyond sonic - sound. Having frequencies above the audible range i.e. above 20000Hz Have applications for imaging, detection
More information12/26/2017. Alberto Ardon M.D.
Alberto Ardon M.D. 1 Preparatory Work Ultrasound Physics http://www.nysora.com/mobile/regionalanesthesia/foundations-of-us-guided-nerve-blockstechniques/index.1.html Basic Ultrasound Handling https://www.youtube.com/watch?v=q2otukhrruc
More informationPersonal Ultrasound The future of ultrasonic scanning is here, today right in your hands. It s portable and affordable giving you the power and
What the Laptop Did for PCs, MySono201 Does for Ultrasonic Scanning The Personal Digital Ultrasound, Only MySono201 Personal Ultrasound The future of ultrasonic scanning is here, today right in your hands.
More informationUltrasound Beamforming and Image Formation. Jeremy J. Dahl
Ultrasound Beamforming and Image Formation Jeremy J. Dahl Overview Ultrasound Concepts Beamforming Image Formation Absorption and TGC Advanced Beamforming Techniques Synthetic Receive Aperture Parallel
More informationLesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.
Lesson 06: Pulse-echo Imaging and Display Modes These lessons contain 26 slides plus 15 multiple-choice questions. These lesson were derived from pages 26 through 32 in the textbook: ULTRASOUND IMAGING
More informationPhysics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล
Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล Diagnosis TTE TEE ICE 3D 4D Evaluation of Cardiac Anatomy Hemodynamic
More informationNuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D
DINFO Dipartimento di Ingegneria dell Informazione Department of Information Engineering Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D Piero Tortoli Microelectronics Systems Design Lab 1 Introduction
More informationSONOACE 6000C MT DIGITAL COLOR. Affordable PC-based Digital CFM Ultrasound System. Specifications.
Specifications Imaging Modes Gray Scale Focusing PC Monitor Speaker Measurements Image Processing Display Functions Peripheral Devices Support Physical Dimensions Electrical Parameters Probe Types Single
More informationLecture 19. Ultrasound Imaging
Lecture 19 Ultrasound Imaging Contents 1. Introduction 2. Ultrasound and its generation 3. Wave propagation in the matter 4. Data acquisition (A, B, M and Doppler model) 5. Imaging reconstruction (5 steps)
More informationChapter 4. Pulse Echo Imaging. where: d = distance v = velocity t = time
Chapter 4 Pulse Echo Imaging Ultrasound imaging systems are based on the principle of pulse echo imaging. These systems require the use of short pulses of ultrasound to create two-dimensional, sectional
More informationKIZLON. Sentinel House,Harvest Crescent, Ancells Business Park, Fleet Hampshire GU51 2UZ, UK Website:
KIZLON Sentinel House,Harvest Crescent, Ancells Business Park, Fleet Hampshire GU51 2UZ, UK Email: info@kizlon.com Website: www.kizlon.com Portable Ultrasound Scanners KUS-A100 & A101 Ultrasound Scanners
More informationDiagnostic Ultrasound System. Operation Note
M5 Diagnostic Ultrasound System Table of Contents System Introduction...3 Control Panel...4 Control Panel...5 Control Panel...6 Control Panel...7 Control Panel...8 Control Panel...9 Power ON / OFF the
More informationAnswer: TGC is needed to amplify echoes from deeper structures so that they appear as bright as similar structures located at more shallow depths.
Q47. When performing a sonogram why the sonographer needs to use the TGC? TGC is needed to amplify echoes from deeper structures so that they appear as bright as similar structures located at more shallow
More informationOPERATING MANUAL MINIDOP ES-100VX POCKET DOPPLER
OPERATING MANUAL MINIDOP ES-100VX POCKET DOPPLER CONTENTS * Features.......................... 1 * Cautions.......................... 2 * Clinical applications................. 4 * Operating controls..................
More informationM5 Diagnostic Ultrasound System
V0807 M5 Diagnostic Ultrasound System Mindray s ultrasound family is now introducing a new member, M5 hand-carried color Doppler system. M5, coming in a laptop size with comprehensive ergonomic design,
More informationUGEO H60. Performance in Style. Features
UGEO H60 Performance in Style The UGEO H60 implements superior performance with new design principles of simplicity and lightness. Its 10.1" touchscreen improves usability while its 18.5" LED monitor enhances
More informationLesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.
Lesson 02: Sound Wave Production This lesson contains 24 slides plus 11 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 2 through 7 in the textbook: ULTRASOUND
More informationBasic functions of the universal flaw detector GEKKO
Product Description GEKKO Portable ultrasonic flaw detector for phased array, TOFD und conventional inspection techniques. Basic functions of the universal flaw detector GEKKO Phased array techniques Phased
More informationIntroduction. Parametric Imaging. The Ultrasound Research Interface: A New Tool for Biomedical Investigations
The Ultrasound Research Interface: A New Tool for Biomedical Investigations Shelby Brunke, Laurent Pelissier, Kris Dickie, Jim Zagzebski, Tim Hall, Thaddeus Wilson Siemens Medical Systems, Issaquah WA
More informationOptimisation of Image Acquisition Bordeaux 16th November J.S. McGhie W.B. Vletter R. Frowijn No disclosures
Optimisation of Image Acquisition Bordeaux 16th November 2016 J.S. McGhie W.B. Vletter R. Frowijn No disclosures Image optimisation: The Echo machine It looks difficult to drive an echo machine!! Some
More informationEMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)
EMAT Application on Incoloy furnace Tubing By Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD) Outlines 1. Introduction EMAT 2. EMAT- Ultrasound waves 3. EMAT-Surface waves 4. EMAT-Guided
More informationEnglish
English Specifications Type Power Source Vibration Frequency Maximum Output Power Consumption Water Pressure Lighting NE134 AC120V 50/60Hz AC230V 50/60Hz 28~32kHz 8W Max. 42VA 0.1~0.5MPa (1~5kgf/cm
More informationQues on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013
Benha University June 2013 Benha Faculty of Engineering Electrical Department Hospital Instrumentations (E472) 4 Th year (control) Dr.Waleed Abdel Aziz Salem Time: 3 Hrs Answer the following questions.
More informationIntroduction to Medical Engineering (Medical Imaging) Ultrasound Imaging. Ho Kyung Kim Pusan National University
Introduction to Medical Engineering (Medical Imaging) Suetens 6 Ultrasound Imaging Ho Kyung Kim Pusan National University Sound Sonic: 20 Hz 20 khz (audible frequency) Subsonic () Ultrasound
More informationPhotomultiplier Tube
Nuclear Medicine Uses a device known as a Gamma Camera. Also known as a Scintillation or Anger Camera. Detects the release of gamma rays from Radionuclide. The radionuclide can be injected, inhaled or
More informationIhor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI
ARCHIVES OF ACOUSTICS 33, 4, 573 580 (2008) LABORATORY SETUP FOR SYNTHETIC APERTURE ULTRASOUND IMAGING Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI Institute of Fundamental Technological Research Polish
More informationBreast Ultrasound QA Phantom Recommended by Japan Association of Breast and Thyroid Sonology
Breast Ultrasound QA Phantom Recommended by Japan Association of Breast and Thyroid Sonology Product supervision: Japan Association of Breast and Thyroid Sonology, Quality Assurance Committee Working Team.
More informationUltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER
UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER DESCRIPTION The UltraFlo UFDD Clamp-On Ultrasonic Flow Meter is the ideal flow meter with accurate, easy-to-use, easy-to-install digital doppler technology.
More informationINTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection
Shantou Institute of Ultrasonic Instruments Co., Ltd. Add: 77 Jinsha Road, Shantou, Guangdong 515041, China Tel: 86-754-88250150 Fax: 86-754-88251499 Http://www.siui.com/ndt Product Data CTS-9009 Digital
More informationVevo770 Ultrasound. Quick Operation Guide
Vevo770 Ultrasound Quick Operation Guide Vevo770 Probe head (707B) Preparation The acoustic membrane is very fragile and sensitive, it must be handled with care. Position the RMV scan head with the fill
More informationSonaFlex. Set of Portable Multifunctional Equipment for Non-contact Ultrasonic Examination of Materials
SonaFlex Set of Portable Multifunctional Equipment for Non-contact Ultrasonic Examination of Materials General Overview of the Testing Equipment SonaFlex is a unique intelligent ultrasonic testing system
More informationExplain what is meant by a photon and state one of its main properties [2]
1 (a) A patient has an X-ray scan taken in hospital. The high-energy X-ray photons interact with the atoms inside the body of the patient. Explain what is meant by a photon and state one of its main properties....
More informationMedical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging
Medical Imaging X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging From: Physics for the IB Diploma Coursebook 6th Edition by Tsokos, Hoeben and Headlee And Higher Level Physics 2 nd Edition
More informationThe physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust
The physics of ultrasound Dr Graeme Taylor Guy s & St Thomas NHS Trust Physics & Instrumentation Modern ultrasound equipment is continually evolving This talk will cover the basics What will be covered?
More informationDC-6. Diagnostic Ultrasound System
DC-6 Diagnostic Ultrasound System DC-6 is a general purpose color Doppler ultrasound system aiming at most clinical areas both in exam and research with various transducers and multi software packages
More informationPropagation of Electromagnetic Waves
Propagation of Electromagnetic Waves REFLECTOR (Water) RADAR ANTENNA Speed of electromagnetic waves used in radar = 300,000,000m/s Speed of electromagnetic waves changes due to temperature, pressure and
More informationThe Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13
Basic Ultrasound Physics Kirk Spencer MD Speaker has no disclosures to make Sound Audible range 20Khz Medical ultrasound Megahertz range Advantages of imaging with ultrasound Directed as a beam Tomographic
More information3. Ultrasound Imaging(2)
3. Ultrasound Imaging(2) Lecture 13, 14 Medical Imaging Systems Jae Gwan Kim, Ph.D. jaekim@gist.ac.kr, X 2220 Department of BioMedical Science and Engineering Gwangju Institute of Sciences and Technology
More informationwww.hitachi-aloka.com Revolutionary Performance; Ease of Use The ProSound 6 is the next generation of compact color ultrasound systems, providing unprecedented performance with a broad range of applications.
More informationTechnische Spezifikation (Technical Specification)
Technical Specification ECHOGRAPH 9/9 Data for: Standard Version and [ m Version] valid for Option N = LF Version / Option SN = Super LF Version according to EN 2668-:2 valid from: 8 June 22 updated: 2
More informationDC-6 Expert. Diagnostic Ultrasound System
DC-6 Expert Diagnostic Ultrasound System MINDRAY has newly released DC-6 Expert, a general purpose color Doppler ultrasound system with full ergonomic designs, supplying more accessible exams, higher imaging
More information: 0089 GTIN
GTIN: 00894912002050 PRECAUTIONS PROBE Non-invasive probes are for transcutaneous use only Probe transducer tips are thin and delicate. Be careful not to drop or hit the probe tip. After use, protect the
More informationIMAGING OF DEFECTS IN CONCRETE COMPONENTS WITH NON-CONTACT ULTRASONIC TESTING W. Hillger, DLR and Ing. Büro Dr. Hillger, Braunschweig, Germany
IMAGING OF DEFECTS IN CONCRETE COMPONENTS WITH NON-CONTACT ULTRASONIC TESTING W. Hillger, DLR and Ing. Büro Dr. Hillger, Braunschweig, Germany Abstract: The building industries require NDT- methods for
More informationUltrasonic A/B Scan GRU-7000
Ultrasonic A/B Scan GRU-7000 GRU-7000 Complete measurement and calculation record within seconds Ability to store up to five different user profiles Fully adjustable tilt for ergonomic comfort Video
More informationUltrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming
Ultrasound Bioinstrumentation Topic 2 (lecture 3) Beamforming Angular Spectrum 2D Fourier transform of aperture Angular spectrum Propagation of Angular Spectrum Propagation as a Linear Spatial Filter Free
More informationPass Ultrasound Physics Exam
Pass Ultrasound Physics Exam Match the Answers By Mansoor Khan MBBS, RDMS, RDCS 1 Copyright 2014 Blue Cube Venture, LLC All rights reserved. The Pass Ultrasound Physics Exam Match the Answers is protected
More informationGSM BASED PATIENT MONITORING SYSTEM
GSM BASED PATIENT MONITORING SYSTEM ABSTRACT This project deals with the monitoring of the patient parameters such as humidity, temperature and heartbeat. Here we have designed a microcontroller based
More informationAttenuation and velocity of ultrasound in solid state materials (transmission)
Attenuation and velocity of ultrasound in solid 5.1.6.08 Related Topics Propagation of ultrasonic waves, time of flight, sound velocity, damping of ultrasonic waves (scattering, reflection, absorption),
More informationETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment
ETL-40V CABLE TEST VAN SYSTEM DC cable testing up to 40kV with 300mA max. current Burning up to 20kV / 1A Surge energy up to 2000J Precise pinpointing and fault prelocation Fault location using step voltage
More informationDigital Ultrasonic Flaw Detector
Digital Ultrasonic Flaw Detector Adjustable Square Wave Pulser High-resolution Display Screen VGA Video Output Portable & Reliable Portable, Easy-to-Use, Reliable Advanced General-Purpose Digital Flaw
More informationM 5. M5 Hand-carried Diagnostic Ultrasound System. Mindray. A practical, durable ultrasound tool for high-quality imaging where and when you need it.
M 5 Mindray M5 Hand-carried Diagnostic Ultrasound System A practical, durable ultrasound tool for high-quality imaging where and when you need it. Affordable, easy-to-use ultrasound for precision and confidence
More informationDigital Ultrasonic Flaw Detector
Digital Ultrasonic Flaw Detector Adjustable Square Wave Pulser High-resolution Display Screen VGA Video Output Portable & Reliable Portable, Easy-to-Use, Reliable Advanced General-Purpose Digital Flaw
More informationNeuVision 500. Abundant and friendly display interface, multifold ECG display screen:
NeuVision 500 Features This monitoring system may be used to monitor patient s 6 physiological parameters: ECG, respiratory rate, body temperature, non-invasive blood pressure (NIBP), pulse oxygen saturation
More informationMulti-spectral acoustical imaging
Multi-spectral acoustical imaging Kentaro NAKAMURA 1 ; Xinhua GUO 2 1 Tokyo Institute of Technology, Japan 2 University of Technology, China ABSTRACT Visualization of object through acoustic waves is generally
More informationUser Manual. Use, Maintenance and Service of the. Sinuscan 301
User Manual Use, Maintenance and Service of the Sinuscan 301 Copyright 2018 Mediq Suomi Oy. All rights reserved. Reproduction, transfer, distribution or storage, in whole or in part, of this document in
More information1. The ray diagram shows the position and size of the image, I, of an object, O, formed by a lens, L.
Medical applications of physics 1. The ray diagram shows the position and size of the image, I, of an object, O, formed by a lens, L. L O P I (a) What type of lens is shown in the ray diagram? Name the
More informationSonic Distance Sensors
Sonic Distance Sensors Introduction - Sound is transmitted through the propagation of pressure in the air. - The speed of sound in the air is normally 331m/sec at 0 o C. - Two of the important characteristics
More information*Notebook is excluded
Biomedical Measurement Training System This equipment is designed for students to learn how to design specific measuring circuits and detect the basic physiological signals with practical operation. Moreover,
More informationEICKEMEYER MAGIC Veterinary Ultrasound System. Operating Manual
EICKEMEYER MAGIC 2500 Veterinary Ultrasound System Operating Manual Eltastraße 8 ~ D-78532 Tuttlingen Telefon +49 74 61 / 9 65 80-0 Telefax +49 74 61 / 9 65 80 90 e-mail: info@eickemeyer.de Internet: http://www.eickemeyer.de
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) ULTRASONIC PRECISION THICKNESS GAGES The Panametrics-NDT Series 35 ultrasonic precision thickness gages provide easy-to-use
More informationLOW FREQUENCY ACOUSTIC (IMPEDANCE) FLAW DETECTORS OF THE NEW GENERATION AND THEIR APPLICATION
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China LOW FREQUENCY ACOUSTIC (IMPEDANCE) FLAW DETECTORS OF THE NEW GENERATION AND THEIR APPLICATION Abstarct Vladimir F. MUZHITSKY,
More informationFig. 1
PhysicsAndMathsTutor.com 1 1. Fig. 1 shows data for the intensity of a parallel beam of X-rays after penetration through varying thicknesses of a material. intensity / MW m 2 thickness / mm 0.91 0.40 0.69
More informationEquipment for Attenuation and velocity of ultrasound in solid state materials (transmission), experimental set-up
Attenuation and velocity of ultrasound in solid TEAS Related Topics Propagation of ultrasonic waves, time of flight, sound velocity, damping of ultrasonic waves (scattering, reflection, absorption), transmission
More informationStandard Guide for Evaluating Characteristics of Ultrasonic Search Units 1
Designation: E 1065 99 An American National Standard Standard Guide for Evaluating Characteristics of Ultrasonic Search Units 1 This standard is issued under the fixed designation E 1065; the number immediately
More informationGeneral information on NKD - 019E «UltraSonic»
General information on NKD - 019E «UltraSonic» A convenient, compact, sophisticated and innovative field instrument, the EMAT Wall Thickness gauge NKD - 019E «UltraSonic» can be used to easily yet precisely
More informationUser Manual. Newman Medical
User Manual Thank you for your purchase of a DigiDop Doppler. The DigiDop was designed to reproduce the sounds of the fetal heartbeats or vascular blood flow. We hope you find the DigiDop to be simple
More informationUltrasonic Linear Array Medical Imaging System
Ultrasonic Linear Array Medical Imaging System R. K. Saha, S. Karmakar, S. Saha, M. Roy, S. Sarkar and S.K. Sen Microelectronics Division, Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata-700064.
More informationUltrasound physical principles in today s technology
Education Ultrasound physical principles in today s technology Brian Starkoff M.App.Sc.(Med. Ultrasound), AMS Holland Park Brisbane Queensland Australia Correspondence to email starkoff@optusnet.com.au
More informationDAMAGE EVALUATION BY FREQUENCY ANALYSIS OF CONTINU- OUS RECORDED AE WAVEFORM
DAMAGE EVALUATION BY FREQUENCY ANALYSIS OF CONTINU- OUS RECORDED AE WAVEFORM KAITA ITO and MANABU ENOKI Department of Materials Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656,
More informationSonoLab Echo-I User Manual
SonoLab Echo-I User Manual Overview: SonoLab Echo-I is a single board digital ultrasound pulse-echo solution. The system has a built in 50 volt high voltage generation circuit, a bipolar pulser, a transmit/receive
More informationCharacterization of Flip Chip Interconnect Failure Modes Using High Frequency Acoustic Micro Imaging With Correlative Analysis
Characterization of Flip Chip Interconnect Failure Modes Using High Frequency Acoustic Micro Imaging With Correlative Analysis Janet E. Semmens and Lawrence W. Kessler SONOSCAN, INC. 530 East Green Street
More informationUltrasound Physics. History: Ultrasound 2/13/2019. Ultrasound
Ultrasound Physics History: Ultrasound Ultrasound 1942: Dr. Karl Theodore Dussik transmission ultrasound investigation of the brain 1949-51: Holmes and Howry subject submerged in water tank to achieve
More informationGSM based Patient monitoring system
For more Project details visit: http://www.projectsof8051.com/patient-monitoring-through-gsm-modem/ Code Project Title 1615 GSM based Patient monitoring system Synopsis for GSM based Patient monitoring
More informationLaser Speckle Reducer LSR-3000 Series
Laser Speckle Reducer LSR-3000 Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A diffuser is bonded to a thin elastic membrane, which includes four independent
More informationThis DDS function generator is designed for use in such applications as communication equipment and electronic components production.
This DDS function generator is designed for use in such applications as communication equipment and electronic components production. Overview This DDS function generator provides a sampling rate of 100
More informationDigitalFlow TM CTF878
DigitalFlow TM CTF878 Panametrics Correlation Tag Clamp-On Gas Ultrasonic Flow Meter Applications The DigitalFlow CTF878 clamp-on gas fl ow meter is a complete ultrasonic fl ow metering system for the
More informationTablet Oscilloscope Data Sheet
Tablet Oscilloscope Data Sheet For tbook Series 2015.1 Shenzhen Micsig Instruments Co., Ltd. Model TO102 TO102A TO104 TO104A TO152 TO152A Channels 2 2 4 4 2 2 Bandwidth 100M 100M 100M 100M 150M 150M Risetime
More informationModel and
Function Generator Model 72-14110 and 72-14111 0 Contents Function Generator... 0 Model 72-14110 and 72-14111... 0 Chapter 1 Safety Information... 3 1.1 Safety Terms and Symbols... 3 1.2 General Safety
More informationSpectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.
Spectrum Analyzers 2394A 1 khz to 13.2 GHz Spectrum Analyzer A spectrum analyzer with outstanding performance and a user friendly visual interface simplifying many complex measurements 1 khz to 13.2 GHz
More informationArchitecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare
Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare 2 DOC1292532 Architecture of Quality Imaging Agile Acoustic Architecture E-Series and XDclear
More informationAdvanced Ultrasonic Imaging for Automotive Spot Weld Quality Testing
5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico Advanced Ultrasonic Imaging for Automotive Spot Weld Quality Testing Alexey A. DENISOV 1, Roman Gr. MAEV 1, Johann ERLEWEIN 2, Holger
More informationSpecification for Conducted Emission Test
1 of 10 1. EMI Receiver Frequency range 9kHz 7.0 GHz Measurement time per frequency 10 µs to 100 s time sweep, span = 0 Hz - 1 µs to 16000 s Sweep time in steps of 5 % frequency sweep, span 10 Hz - 2.5
More informationA-level PHYSICS A PHYA5/2B. Unit 5B Medical Physics. Section B. Tuesday 28 June 2016
Please write clearly in block capitals. Centre number Candidate number Surname Forename(s) Candidate signature A-level PHYSICS A Unit 5B Medical Physics Section B Tuesday 28 June 2016 Materials For this
More informationEVIS EUS ENDOSCOPIC ULTRASOUND CENTER EU-ME2 Dedicated ultrasound processor with versatile functionality.
EVIS EUS ENDOSCOPIC ULTRASOUND CENTER EU-ME2 Dedicated ultrasound processor with versatile functionality. Advancing the Art of Endosonography The EU-ME2 is a high-quality compact ultrasound processor for
More informationIsolation Scanner. Advanced evaluation of wellbore integrity
Isolation Scanner Advanced evaluation of wellbore integrity Isolation Scanner* cement evaluation service integrates the conventional pulse-echo technique with flexural wave propagation to fully characterize
More informationThe following symbol indicates that the device is MR-unsafe:
The following symbol indicates that the device is MR-unsafe: MR Unsafe Do not use this equipment In the MRI scan room Patient must follow the doctor s instructions and should not perform a self-assessment
More informationA COMPACT SYSTEM WITH ADVANCED PERFORMANCE
Samsung Medison is a global leading medical devices company. Founded in 1985, the company sells cutting-edge diagnostic ultrasound devices around the world in various medical fields. The company has attracted
More informationRadionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM
Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM Preamplifiers and amplifiers The current from PMT must be further amplified before it can be processed and counted (the number of electrons yielded
More informationCOMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES
Paper presented at the 23rd Acoustical Imaging Symposium, Boston, Massachusetts, USA, April 13-16, 1997: COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES Jørgen Arendt Jensen and Peter
More informationDavidsonSensors. Fiber Optic Sensing System Definitions. Davidson Fiber Optic Sensing System
DavidsonSensors October 2007 Fiber Optic Sensing System Davidson Fiber Optic Sensing System DavidsonSensors Measure Temperature, Pressure, Vacuum, Flow, Level, and Vibration DavidsonSensors Transmit Intrinsically
More informationTopics 8/2/2017. Opportunities for ultrasonic imaging with software beamformation
Opportunities for ultrasonic imaging with software beamformation Kai E Thomenius, PhD FAIUM Research Scientist, MIT Topics Ultrasound scanner as a probe and a processor Software beamformation (SWBF) What
More informationReal Time Deconvolution of In-Vivo Ultrasound Images
Paper presented at the IEEE International Ultrasonics Symposium, Prague, Czech Republic, 3: Real Time Deconvolution of In-Vivo Ultrasound Images Jørgen Arendt Jensen Center for Fast Ultrasound Imaging,
More informationCaring for your image
Caring for your image Based in Angouleme in Southwest France, ECM concentrates at this location the various talents of our highly skilled ultrasound know-how (Research and Development, Production, Marketing
More informationMFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements
MFD900 The most industrial ultrasonic test system for flaw detection and thickness measurements Guaranteed the lowest possible down time over many years. Pure ultrasonic testpower for high speed off- line
More informationChapter 8. Ultrasound Medical Diagnostic Instrumentation PART-I
Chapter 8 Ultrasound Medical Diagnostic Instrumentation PART-I ULTRASONAGRAPHY Ultrasonography is a technique by which ultrasonic energy is used to detect internal body organs. Bursts of ultrasound energy
More informationFLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual
SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS
More information