1 Vevo770 Ultrasound Quick Operation Guide

2 Vevo770 Probe head (707B) Preparation The acoustic membrane is very fragile and sensitive, it must be handled with care. Position the RMV scan head with the fill port pointing upward. Fill the nosepiece with de-ionized water using the supplied water bottle until the nosepiece is almost full. Using your thumb, cover the fill port and tap the scanhead several times to dislodge any air bubbles in the nosepiece. Check to ensure that the face of the transducer does not contain bubbles. If bubbles appear, tilt the RMV scanhead to dislodge them. Orient the nosepiece so that the remaining air bubbles are placed under the fill port, and finish filling the nosepiece with the syringe. Insert and tighten the fill port screw with a screwdriver. Do not over-tighten the fill port Real-Time Microvisualization (RMV) Scan Head Fill Port Screw Nosepiece Transducer Acoustic Membrane Nosepiece Pressure fit groove RMV cable Transducer Arm Acoustic Window

3 Pre-Image Preparation-Animal Preparation Warm up the stage The stage warmer, heart and temperature monitors each have a simple on/off button on the control pad Located on the table to the left of the stage Turn on the stage heater-this helps to maintain mouse body temperature Study Subject Preparation ultrasound is most effective with no hair. Depilate the scan area of the animal using a razor or depilatory cream (Nair) Be sure to remove the NAIR as it can easily burn the mouse. Put electrode contact gel (Sigma) or imaging gel on all 4 of the foot pads on stage base. Tape mouse down on platform so that all four of its feet are on the appropriate foot pad and in contact with the probe This will monitor the mouse s heart rate and respiration the heart rate should be between approximately 370 and 400 beats per minute Prior to placing imaging gel on the mouse, take a small amount of gel and smooth it over the surface of the image area to remove small air bubbles at the skin level. Place 1-2 inches of gel on the image area, lower the scan head into the gel. Make sure to avoid bubbles 3

4 Study Information Set up a study Turn on the instrument and computer The system main power switch is a large toggle switch on the back right hand side of the imager PC power is activated by small toggle switch on the left side of the unit near the DVD drive-if this switch is not working, the main computer power button is below the console. Open the Visual Sonics program, from the desktop icon If an error code comes up simply click okay Initialize scan head Select or add operator Set up new study, click the New tab Fill in spaces for user and project info Select scanning mode from the keypad B-mode: basic scanning, two dimensional images and cine loops Doppler Mode: measures velocity of blood flow from a field of view (FOV) Power Doppler: measures flow volume or noise in 2 or 3-D from an FOV. Menu Scan head initialization Study Browser New Study Scan Head selection (use default) Initialize Add Operator 4

5 Image acquisition/saving For all modes, start imaging in B-mode to identify an area of interest If you want to have respiration and cardiac information included in the session, press the view tab on the tools menu Select the desired features To save a single image select Frame Store, press Ctrl +L to label and save data Menu tab View To save a video loop up up to 300 frames press Scan Freeze ; this tab will both start and stop data acquisition. The last 300 frames will be saved, to save the data press Cine Store then Ctrl +L to label and save the movie At the conclusion of your study, in the Tool menu Study tab Close Study; Commit Session Data tab to save -Data location is Data D: vevo770 \data\(your files) 5

6 B-Mode: basic scanning, two dimensional images and cine loops The line in this icon corresponds to the orientation ridge on the RMV scanhead and indicates the orientation of the RMV scanhead relative to the image. B-Mode ultrasound image window. The time-gain compensation (TGC) sliders specify the receive gain to be used for acquiring different sections of a B-Mode image. To toggle between the basic and detailed display parameters views, click Details or press <Ctrl+D>. The depth ruler indicates the depth from the transducer face. The triangular arrow indicates the focal length of the transducer. The grayscale bar indicates the dynamic range of the display. Cine loop playback controls. Physiological Data trace. The cine loop range control slider defines a subset of the cine loop to be played back or saved. 6

7 Define a Field of View (FOV) for PW Doppler studies Defining the Sample Volume and Doppler angle must be done in B-Mode Defining the PW Doppler Sample Volume Select Overlay > PW Doppler Sample Volume Wire-frame Move the trackball cursor over the red vertical line, left up click to move sample volume The trackball cursor is displayed as a crosshair when it is within a region that can be repositioned. Left-click the position line. Use the trackball cursor to move the overlay. Left-click again to place the Sample Volume. The Sample Volume details are updated in the parameters display. Defining the PW Doppler Angle. Start acquiring B-Mode data. From the B-Mode window, position the trackball cursor over the PW Doppler angle line (displayed as a dotted yellow or blue line). The trackball cursor changes to a crosshair. Right up-click to activate editing of the PW Doppler angle line. The angle line follows the movement of the trackball cursor. When the angle is at the desired setting, right-click to set the angle. VisualSonics recommends a PW Doppler angle that is between 0 and 60 for the most accurate velocity estimate. PW Doppler Sample Volume positioning line PW Doppler angle PW Doppler Sample Volume 7

8 PW Doppler Mode: measures velocity of blood flow from a field of view (FOV) Scout window Sample Volume position Angle measurement The frequency Scale indicates the frequency shift in the acquired PW Doppler signal. The grayscale bar indicates the dynamic range of the display. Time scale in milliseconds. The image area is a right-to-left scrolling display. The most recently acquired data appears on the right of the window. ECG trace The velocity scale indicates the velocity of the measured PW Doppler signal. 8

9 Power Doppler: measures flow volume or noise in 2 or 3-D from an FOV. Priority indicator Time-gain compensation (TGC) sliders Gray-scale bar Power Doppler Acquisition Parameters Power Doppler Histogram 9

VisualSonics Application Protocol Subharmonic Imaging using MicroMarker Non-Targeted Contrast Agents in the Kidney

VisualSonics Application Protocol Subharmonic Imaging using MicroMarker Non-Targeted Contrast Agents in the Kidney VisualSonics Application Protocol Subharmonic Imaging using MicroMarker Non-Targeted Contrast Agents in the Kidney 1 Objective Part Number: 11851 The objective of the Subharmonic Imaging using MicroMarker

More information

S S S2 Operation Manual

S S S2 Operation Manual PREPARATION 1. How to create and input patient data? In the MAIN INTERFACE, press the key, to enter into the patient exam list interface. Then, click New patient item to create new patient files. Patient

More information

4 Working With Scan Modes

4 Working With Scan Modes 4 Working With Scan Modes Scan Modes Overview All of the information in this chapter pertains to live imaging. Many of the controls and functions change when you freeze the scan. For information on using

More information

Diagnostic Ultrasound System. Operation Note

Diagnostic Ultrasound System. Operation Note M5 Diagnostic Ultrasound System Table of Contents System Introduction...3 Control Panel...4 Control Panel...5 Control Panel...6 Control Panel...7 Control Panel...8 Control Panel...9 Power ON / OFF the

More information

M7Vet Diagnostic Ultrasound System. Operation Note

M7Vet Diagnostic Ultrasound System. Operation Note M7Vet Diagnostic Ultrasound System Operation Note Table of Contents Table of Contents... i 1 System Introduction... 1 2 Control Panel... 2 3 Icons on the Screens... 6 4 Power ON/ OFF... 7 5 Enter or Search

More information

Quick Reference Guide

Quick Reference Guide siemens.com/nx3 Quick Reference Guide ACUSON NX3 Series Contents 2 System Overview 3 Getting Started 8 2D Mode and M-mode 12 Color and Spectral Doppler 24 Measurements and Calculations 38 Text, Arrows

More information

M5 Diagnostic Ultrasound System

M5 Diagnostic Ultrasound System V0807 M5 Diagnostic Ultrasound System Mindray s ultrasound family is now introducing a new member, M5 hand-carried color Doppler system. M5, coming in a laptop size with comprehensive ergonomic design,

More information

Photo One Digital Photo Shoots and Edits

Photo One Digital Photo Shoots and Edits Photo One Digital Photo Shoots and Edits You will submit photo shoots, unedited and you will submit selected edited images. The shoots will be explained first and the edits will be explained later on this

More information

Ultrasound Diagnostic Scanner INSTRUCTION MANUAL

Ultrasound Diagnostic Scanner INSTRUCTION MANUAL Ultrasound Diagnostic Scanner HI VISION Avius Operation INSTRUCTION MANUAL Special Notes to Operators and Maintenance Managers Before using this system, be sure to thoroughly read this manual and make

More information

Duplicate Layer 1 by dragging it and dropping it on top of the New Layer icon in the Layer s Palette. You should now have two layers rename the top la

Duplicate Layer 1 by dragging it and dropping it on top of the New Layer icon in the Layer s Palette. You should now have two layers rename the top la 50 Face Project For this project, you are going to put your face on a coin. The object is to make it look as real as possible. Though you will probably be able to tell your project was computer generated,

More information

Apex v5 Assessor Introductory Tutorial

Apex v5 Assessor Introductory Tutorial Apex v5 Assessor Introductory Tutorial Apex v5 Assessor Apex v5 Assessor includes some minor User Interface updates from the v4 program but attempts have been made to simplify the UI for streamlined work

More information

Digital Microscope. User Manual

Digital Microscope. User Manual Digital Microscope User Manual Features The digital microscope provides 10~200X adjustable magnification range. The build-in high-performance white LED can illuminate the object without using any auxiliary

More information

DC-6 Expert. Diagnostic Ultrasound System

DC-6 Expert. Diagnostic Ultrasound System DC-6 Expert Diagnostic Ultrasound System MINDRAY has newly released DC-6 Expert, a general purpose color Doppler ultrasound system with full ergonomic designs, supplying more accessible exams, higher imaging

More information

The Main Screen. Viewing Area - show the photos that were selected in the Source List.

The Main Screen. Viewing Area - show the photos that were selected in the Source List. iphoto 11 The Main Screen Source List - This is where the Library, Events and Albums are identified. It is the place where photos can be organized and accessed. The Source List can also contain the slideshows,

More information

Chapter 6: TVA MR and Cardiac Function

Chapter 6: TVA MR and Cardiac Function Chapter 6 Cardiac MR Introduction Chapter 6: TVA MR and Cardiac Function The Time-Volume Analysis (TVA) optional module calculates time-dependent behavior of volumes in multi-phase studies from MR. An

More information

OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER

OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER WARNING Only a physician can order a Holter ECG test. WARNING Only the ordering physician can decide on the application technique used for affixing

More information

A Quick Guide to ios 12 s New Measure App

A Quick Guide to ios 12 s New Measure App A Quick Guide to ios 12 s New Measure App Steve Sande For the past several years, Apple has been talking about AR augmented reality a lot. The company believes that augmented reality, which involves overlaying

More information

Zoom Set Too Tight Zoom Set Correctly Zoom Set Too Wide

Zoom Set Too Tight Zoom Set Correctly Zoom Set Too Wide The ISG-E300 AutoCam Elite offers special features that increase capture efficiency and enhance image quality. By following the procedures outlined in this document, the ISG-E300 Elite can be used to its

More information

Zeiss 880 Training Notes Zen 2.3

Zeiss 880 Training Notes Zen 2.3 Zeiss 880 Training Notes Zen 2.3 1 Turn on the HXP 120V Lamp 2 Turn on Main Power Switch Turn on the Systems PC Switch Turn on the Components Switch. 3 4 5 Turn on the PC and log into your account. Start

More information

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer ThermaViz The Innovative Two-Wavelength Imaging Pyrometer Operating Manual The integration of advanced optical diagnostics and intelligent materials processing for temperature measurement and process control.

More information

Accutome Connect Visual Aid

Accutome Connect Visual Aid Accutome Connect Visual Aid Table of Contents A-Scan Mode Page 3 B-Scan Mode Page 15 UBM.. Page 23 B-Scan/UBM Recording.. Page 31 2 Accutome Connect: A-Scan 3 Probe Position 2. 1. Insert probe through

More information

iphoto Objective Course Outline

iphoto Objective Course Outline iphoto Objective In this class participants will learn how iphoto creates a photo center for photo organization by using rolls and albums. Participants will also learn the built-in editing tools. Participants

More information

Google Earth Tutorials

Google Earth Tutorials Google Earth Tutorials Tutorial 1 Beginner Videos 1: Street View Now you can fly from outer space down to the streets with Street View. Seamlessly integrated with Google Earth, Street View lets you experience

More information

Getting Started. with Easy Blue Print

Getting Started. with Easy Blue Print Getting Started with Easy Blue Print User Interface Overview Easy Blue Print is a simple drawing program that will allow you to create professional-looking 2D floor plan drawings. This guide covers the

More information

TeleTrader FlashChart

TeleTrader FlashChart TeleTrader FlashChart Symbols and Chart Settings With TeleTrader FlashChart you can display several symbols (for example indices, securities or currency pairs) in an interactive chart. You can also add

More information

Embroidery process - EC on PC

Embroidery process - EC on PC 66 Software EC on PC Embroidery process - EC on PC PC display Motif the motif is displayed in color the smallest possible hoop for the selected motif is displayed the needle position (marked by a fine

More information

Creating Digital Stories for the Classroom

Creating Digital Stories for the Classroom Using Photo Story 3 to Create a Digital Story Creating Digital Stories for the Classroom When you open Photo Story 3 you have a few options. To begin a new story select the option Begin a New Story and

More information

Operating Rausch ScanCam within POSM.

Operating Rausch ScanCam within POSM. Operating Rausch ScanCam within POSM. POSM (Pipeline Observation System Management) // posmsoftware.com // info@posmsoftware.com // 859-274-0041 RAUSCH USA // www.rauschusa.com // reusa@rauschusa.com //

More information

Pull Down Menu View Toolbar Design Toolbar

Pull Down Menu View Toolbar Design Toolbar Pro/DESKTOP Interface The instructions in this tutorial refer to the Pro/DESKTOP interface and toolbars. The illustration below describes the main elements of the graphical interface and toolbars. Pull

More information

1. Preliminary sample preparation

1. Preliminary sample preparation FEI Helios NanoLab 600 standard operating procedure Nicholas G. Rudawski ngr@ufl.edu (352) 392 3077 (office) (805) 252-4916 (cell) Last updated: 03/02/18 What this document provides: an overview of basic

More information

Virtual I.V. System overview. Directions for Use.

Virtual I.V. System overview. Directions for Use. System overview 37 System Overview Virtual I.V. 6.1 Software Overview The Virtual I.V. Self-Directed Learning System software consists of two distinct parts: (1) The basic menus screens, which present

More information

Instruction Manual for HyperScan Spectrometer

Instruction Manual for HyperScan Spectrometer August 2006 Version 1.1 Table of Contents Section Page 1 Hardware... 1 2 Mounting Procedure... 2 3 CCD Alignment... 6 4 Software... 7 5 Wiring Diagram... 19 1 HARDWARE While it is not necessary to have

More information

The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line

The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line AV-9100 Single Channel ECG 1 2 AV-9300 3-Channels ECG 3 4 5 AV-9000B Multi-Parameter Patient Monitor 6 7 8 AV-9000C

More information

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions Starting up: Schematic of Olympus BX-61. 1. Turn on Olympus microscope power box (left of microscope) with toggle switch on

More information

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING Operations Guide Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING Nikon Eclipse 90i Operations Guide STARTUP Startup Powering Up Fluorescence

More information

DC-6. Diagnostic Ultrasound System

DC-6. Diagnostic Ultrasound System DC-6 Diagnostic Ultrasound System DC-6 is a general purpose color Doppler ultrasound system aiming at most clinical areas both in exam and research with various transducers and multi software packages

More information

New Sketch Editing/Adding

New Sketch Editing/Adding New Sketch Editing/Adding 1. 2. 3. 4. 5. 6. 1. This button will bring the entire sketch to view in the window, which is the Default display. This is used to return to a view of the entire sketch after

More information

FlashChart. Symbols and Chart Settings. Main menu navigation. Data compression and time period of the chart. Chart types.

FlashChart. Symbols and Chart Settings. Main menu navigation. Data compression and time period of the chart. Chart types. FlashChart Symbols and Chart Settings With FlashChart you can display several symbols (for example indices, securities or currency pairs) in an interactive chart. You can also add indicators and draw on

More information

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop 1. Log in usage using the SMIF web site 2. Turn power

More information

Tutorial 2: Setting up the Drawing Environment

Tutorial 2: Setting up the Drawing Environment Drawing size With AutoCAD all drawings are done to FULL SCALE. The drawing limits will depend on the size of the items being drawn. For example if our drawing is the plan of a floor 23.8m X 15m then we

More information

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging

User Manual for HoloStudio M4 2.5 with HoloMonitor M4. Phase Holographic Imaging User Manual for HoloStudio M4 2.5 with HoloMonitor M4 Phase Holographic Imaging 1 2 HoloStudio M4 2.5 Software instruction manual 2013 Phase Holographic Imaging AB 3 Contact us: Phase Holographic Imaging

More information

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual Scanning Electron Microscope FEI INSPECT F50 Step by step operation manual Scanning Electron Microscope, FEI Inspect F50 FE-SEM-F Observation Flow Saving Data And Analysis Specimen preparation Error check

More information

Setting up Pro Tools I/O & connecting a microphone for Recording

Setting up Pro Tools I/O & connecting a microphone for Recording Setting up Pro Tools I/O & connecting a microphone for Recording The purpose of this lab is to demonstrate the ability to correctly connect a microphone to the Fast Track Pro interface in such a way that

More information

Audacity 5EBI Manual

Audacity 5EBI Manual Audacity 5EBI Manual (February 2018 How to use this manual? This manual is designed to be used following a hands-on practice procedure. However, you must read it at least once through in its entirety before

More information

Mac User s Manual for the CamRanger, CamRanger Share, and CamRanger PT Hub & Tripod. Supports Mac OS 10.7/Lion, 10.8/Mountain Lion, and Mavericks

Mac User s Manual for the CamRanger, CamRanger Share, and CamRanger PT Hub & Tripod. Supports Mac OS 10.7/Lion, 10.8/Mountain Lion, and Mavericks Mac User s Manual for the CamRanger, CamRanger Share, and CamRanger PT Hub & Tripod Supports Mac OS 10.7/Lion, 10.8/Mountain Lion, and Mavericks Table of Contents CamRanger Hardware... 3 CamRanger Registration...

More information

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL MIF ZEISS LSM510 CONFOCAL USER PROTOCOL START-UP Turn on the Mercury Bulb Power Supply (if needed). Power-on the Control Box. Turn on the computer. Open the LSM 510 software. Choose Scan New Images and

More information

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK / ADI-100 Interrupter Operator s Manual 526 S. Seminole Bartlesville, OK 74003 918/336-1221 www.sescocp.com ADI - 100 Interrupter FEATURES Clock Accuracy 100% during GPS lock Clock Drift 30 µsec per degree

More information

VCS SKETCH User Group Meeting

VCS SKETCH User Group Meeting VCS SKETCH 2009 User Group Meeting From Field To Finished in CAMAvision Accessing Sketch in Parcel Maintenance To get started with Sketch open CAMAvision enter Parcel Maintenance and load the parcel you

More information

Embroidery Gatherings

Embroidery Gatherings Planning Machine Embroidery Digitizing and Designs Floriani FTCU Digitizing Fill stitches with a hole Or Add a hole to a Filled stitch object Create a digitizing plan It may be helpful to print a photocopy

More information

MEASUREMENT CAMERA USER GUIDE

MEASUREMENT CAMERA USER GUIDE How to use your Aven camera s imaging and measurement tools Part 1 of this guide identifies software icons for on-screen functions, camera settings and measurement tools. Part 2 provides step-by-step operating

More information

Leica SPEII confocal microscope. Short Manual

Leica SPEII confocal microscope. Short Manual Leica SPEII confocal microscope Short Manual Switching ON sequence: 1. Turn on the Workstation under the bench (top, far right). 2. Turn on the Supply Unit - Laser box (big green switch first and then

More information

Managing images with NewZapp

Managing images with NewZapp Managing images with NewZapp This guide is for anyone using the NewZapp Fixed editor as opposed to the Drag and Drop editor. The Image Manager is where images are uploaded and stored in your NewZapp account

More information

1.1. Log on to the TUMI system (you cannot proceed further until this is done).

1.1. Log on to the TUMI system (you cannot proceed further until this is done). FEI DB235 SEM mode operation Nicholas G. Rudawski ngr@ufl.edu (805) 252-4916 1. Sample loading 1.1. Log on to the TUMI system (you cannot proceed further until this is done). 1.2. The FIB software (xp)

More information

Education. Program comes with one model, Nina. Her measurements are changed to reflect your shape.

Education. Program comes with one model, Nina. Her measurements are changed to reflect your shape. My Label Mastery Opening Program Education Double click on the My Label icon on the screen to open My Label. The screen is divided into four main areas: 1. Drawer area, where items are selected 2. Worktable

More information

RASim Prototype User Manual

RASim Prototype User Manual 7 th Framework Programme This project has received funding from the European Union s Seventh Framework Programme for research, technological development and demonstration under grant agreement no 610425

More information

Tinker Tuesday Project - Drinking Glasses

Tinker Tuesday Project - Drinking Glasses Tinker Tuesday Project - Drinking Glasses 1. Open CorelDRAW and create a new document. Near the top left corner of the screen, click File, and then click Import on the resulting menu. Select an image from

More information

Start Here. Unpack Contents. Install Software. Installing your Microtek Bio-5000 Plus

Start Here. Unpack Contents. Install Software. Installing your Microtek Bio-5000 Plus Start Here Installing your Microtek Bio-5000 Plus Unpack Contents Unpack your scanner package and check for major components. 1. Bio-5000 Plus scanner 2. Hi-Speed USB cable LEAK-FREE GLASS HOLDER This

More information

Mighty Scope 5M. Instruction Manual. aveninc.com

Mighty Scope 5M. Instruction Manual. aveninc.com Mighty Scope 5M Instruction Manual aveninc.com Contents Features 2 Specifications 2 Contents 2 PC System Requirements 3 Driver Installation Procedure 3 Getting Started 3 Software Installation (PC) 4 Mighty

More information

MicroLab 500-series Getting Started

MicroLab 500-series Getting Started MicroLab 500-series Getting Started 2 Contents CHAPTER 1: Getting Started Connecting the Hardware....6 Installing the USB driver......6 Installing the Software.....8 Starting a new Experiment...8 CHAPTER

More information

Visioneer OneTouch Scanner. Installation Guide FOR WINDOWS

Visioneer OneTouch Scanner. Installation Guide FOR WINDOWS Visioneer OneTouch Scanner Installation Guide FOR WINDOWS TABLE OF CONTENTS i TABLE OF CONTENTS Getting Started with your new Scanner....................... 1 Step 1: Installing the Scanner Software.......................

More information

SDI. Table of Contents

SDI. Table of Contents NMSC-2 User Manual 2 Table of Contents Introduction........ 4 Hardware Installation.... 5 NMSC Power On.. 8 Overview... 9 FFT Measurement Screen.. 10 FFT Setup..... 11 FFT Detector..... 14 FFT Calibration.....

More information

2.2 Laser Etching with BoXZY. This manual will get you started laser etching with BoXZY. Written By: BoXZY boxzy.dozuki.

2.2 Laser Etching with BoXZY. This manual will get you started laser etching with BoXZY. Written By: BoXZY boxzy.dozuki. 2.2 Laser Etching with BoXZY This manual will get you started laser etching with BoXZY. Written By: BoXZY 2018 boxzy.dozuki.com/ Page 1 of 18 INTRODUCTION This manual will guide you through a two-part

More information

Experiment 1 Introduction to Simulink

Experiment 1 Introduction to Simulink 1 Experiment 1 Introduction to Simulink 1.1 Objective The objective of Experiment #1 is to familiarize the students with simulation of power electronic circuits in Matlab/Simulink environment. Please follow

More information

Software Manual for the Economy LBIC Demo

Software Manual for the Economy LBIC Demo printed organic photovoltaics solar testing euipment specialty materials Software Manual for the Economy LBIC Demo Introduction This demonstration program is meant to show the capabilities of the infinitypv

More information

6 MASKS AND CHANNELS. Lesson overview

6 MASKS AND CHANNELS. Lesson overview 6 MASKS AND CHANNELS Lesson overview In this lesson, you ll learn how to do the following: Create a mask to remove a subject from a background. Refine a mask to include complex edges. Create a quick mask

More information

2. Advanced Image editing

2. Advanced Image editing Aim: In this lesson, you will learn: 2. Advanced Image editing Tejas: We have some pictures with us. We want to insert these pictures in a story that we are writing. Jyoti: Some of the pictures need modification

More information

Paper Prototyping Kit

Paper Prototyping Kit Paper Prototyping Kit Share Your Minecraft UI IDEAs! Overview The Minecraft team is constantly looking to improve the game and make it more enjoyable, and we can use your help! We always want to get lots

More information

PERFORM Operating Document. Use and Maintenance of G.E. Ultrasound LOGIQ E

PERFORM Operating Document. Use and Maintenance of G.E. Ultrasound LOGIQ E PERFORM Operating Document Use and Maintenance of G.E. Ultrasound LOGIQ E PC-POD-IM-001-v02 Revision History Version Reason for Revision Date 01 New POD 22/May/2013 02 Minor changes only 2.2 Change responsibility

More information

LSM 780 Confocal Microscope Standard Operation Protocol

LSM 780 Confocal Microscope Standard Operation Protocol LSM 780 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Sign on log sheet according to Actual start time 2. Check Compressed Air supply for the air table 3. Switch

More information

JorVet. Hand-Held Doppler. Operating Manual. Jorgensen Laboratories, Inc. Loveland, Colorado 80538

JorVet. Hand-Held Doppler. Operating Manual. Jorgensen Laboratories, Inc. Loveland, Colorado 80538 JorVet Hand-Held Doppler Operating Manual Jorgensen Laboratories, Inc. Loveland, Colorado 80538 Thank You! for choosing the JorVet Hand-Held Doppler! This choice acknowledges the many advantages of the

More information

For customers in USA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

For customers in USA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: User manual For customers in North and South America For customers in USA This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not

More information

Micro-Image Capture 8 Installation Instructions & User Guide

Micro-Image Capture 8 Installation Instructions & User Guide Micro-Image Capture 8 Installation Instructions & User Guide Software installation: Micro-Image Capture Software 1. Load Micro-Image Capture software CD onto host PC. Auto Run should start driver/software

More information

User Manual Veterinary

User Manual Veterinary Veterinary Acquisition and diagnostic software Doc No.: Rev 1.0.1 Aug 2013 Part No.: CR-FPM-04-022-EN-S 3DISC, FireCR, Quantor and the 3D Cube are trademarks of 3D Imaging & Simulations Corp, South Korea,

More information

Share My Design Space Project to Facebook or Pinterest?

Share My Design Space Project to Facebook or Pinterest? How Do I Share My Design Space Project to Facebook or Pinterest? We love it when our members share the projects they create daily with their Cricut machines, materials, and accessories. Design Space was

More information

Contents Technical background II. RUMBA technical specifications III. Hardware connection IV. Set-up of the instrument Laboratory set-up

Contents Technical background II. RUMBA technical specifications III. Hardware connection IV. Set-up of the instrument Laboratory set-up RUMBA User Manual Contents I. Technical background... 3 II. RUMBA technical specifications... 3 III. Hardware connection... 3 IV. Set-up of the instrument... 4 1. Laboratory set-up... 4 2. In-vivo set-up...

More information

Transmission Lines and TDR

Transmission Lines and TDR Transmission Lines and TDR Overview This is the procedure for lab 2b. This is a one- week lab. The prelab should be done BEFORE going to the lab session. In this lab, pulse propagation down transmission

More information

ACUSON X150 Knobology & User Guide

ACUSON X150 Knobology & User Guide ACUSON X150 Knobology & User Guide ACUSON X150 CONTROL PANEL Table of Contents The ACUSON X150 knobology and user guide is the clinicians quick reference of system terms, functions and capabilities. This

More information

LSM 800 Confocal Microscope Standard Operation Protocol

LSM 800 Confocal Microscope Standard Operation Protocol LSM 800 Confocal Microscope Standard Operation Protocol Turning on the system 1. Switch on the Main switch (labeled 1 and 2 ) mounted on the wall. 2. Turn the Laser Key (labeled 3 ) 90 clockwise for power

More information

Apple Photos Quick Start Guide

Apple Photos Quick Start Guide Apple Photos Quick Start Guide Photos is Apple s replacement for iphoto. It is a photograph organizational tool that allows users to view and make basic changes to photos, create slideshows, albums, photo

More information

LSM 710 Confocal Microscope Standard Operation Protocol

LSM 710 Confocal Microscope Standard Operation Protocol LSM 710 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Switch on Main power switch 2. Switch on System / PC power button 3. Switch on Components power button 4.

More information

Operating Checklist for using the Scanning Electron. Microscope, JEOL JSM 6400.

Operating Checklist for using the Scanning Electron. Microscope, JEOL JSM 6400. Smith College August 2009 Operating Checklist for using the Scanning Electron Microscope, JEOL JSM 6400. CONTENT, page no. Pre-Check 1 Startup 1 Specimen Insertion 2 Filament Saturation 2 Beam Alignment

More information

ME Week 2 Project 2 Flange Manifold Part

ME Week 2 Project 2 Flange Manifold Part 1 Project 2 - Flange Manifold Part 1.1 Instructions This project focuses on additional sketching methods and sketching commands. Revolve and Work features are also introduced. The part being modeled is

More information

Laboratory 1: Motion in One Dimension

Laboratory 1: Motion in One Dimension Phys 131L Spring 2018 Laboratory 1: Motion in One Dimension Classical physics describes the motion of objects with the fundamental goal of tracking the position of an object as time passes. The simplest

More information

Microscopy from Carl Zeiss

Microscopy from Carl Zeiss Microscopy from Carl Zeiss Contents Page Contents... 1 Introduction... 1 Starting the System... 2 Introduction to ZEN Efficient Navigation... 5 Setting up the microscope... 10 Configuring the beam path

More information

Generations Automatic Stand-Alone Lace By Bernie Griffith Generations Software

Generations Automatic Stand-Alone Lace By Bernie Griffith Generations Software We are going to create an open Italian lace. Generations software products provide advanced image processing features allowing for the creation of stand-alone lace with just a few simple techniques. A

More information

Tinker Tuesday Project - Pumpkin Carving

Tinker Tuesday Project - Pumpkin Carving Tinker Tuesday Project - Pumpkin Carving 1. Acquire a small pumpkin (between six and seven inches tall excluding the stem). A full size pumpkin will not fit in the engraver. 2. Use a knife to remove the

More information

AutoCAD Tutorial First Level. 2D Fundamentals. Randy H. Shih SDC. Better Textbooks. Lower Prices.

AutoCAD Tutorial First Level. 2D Fundamentals. Randy H. Shih SDC. Better Textbooks. Lower Prices. AutoCAD 2018 Tutorial First Level 2D Fundamentals Randy H. Shih SDC PUBLICATIONS Better Textbooks. Lower Prices. www.sdcpublications.com Powered by TCPDF (www.tcpdf.org) Visit the following websites to

More information

ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide

ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide ScanGear CS-U 5.3 for CanoScan FB630U/FB636U Color Image Scanner User s Guide Copyright Notice 1999 Canon Inc. This manual is copyrighted with all rights reserved. Under the copyright laws, this manual

More information

Information & Instructions

Information & Instructions KEY FEATURES 1. USB 3.0 For the Fastest Transfer Rates Up to 10X faster than regular USB 2.0 connections (also USB 2.0 compatible) 2. High Resolution 4.2 MegaPixels resolution gives accurate profile measurements

More information

Fire CR Calibration Guide

Fire CR Calibration Guide 1 Fire CR Calibration Guide This reference guide will guide you through the steps to complete the calibration for the Fire CR.. Getting Started: 1. Click on the Opal Icon on the Desktop. Figure 1 2. Once

More information

USB.007 Studio Quality USB Stereo Condenser Mic. User Manual

USB.007 Studio Quality USB Stereo Condenser Mic. User Manual USB.007 Studio Quality USB Stereo Condenser Mic User Manual Congratulations on your purchase of the MXL USB.007 which uses two gold diaphragm capsules in an X/Y pattern for stereo recording. MXL microphones

More information

Contents. Introduction

Contents. Introduction Contents Page Contents... 1 Introduction... 1 Starting the System... 2 Introduction to ZEN Efficient Navigation... 5 Setting up the microscope... 10 Configuring the beam path and lasers... 12 Scanning

More information

MXL USB.006.

MXL USB.006. MXL USB.006 www.mxlmics.com Congratulations on your purchase of the MXL USB.006 which uses a large 32mm gold diaphragm capsule for added warmth. MXL microphones are the result of world-class engineering

More information

ACI Sketch. Copyright October 2008, ACI All Rights Reserved. 24 Old Kings Road North Palm Coast, FL appraiserschoice.com

ACI Sketch. Copyright October 2008, ACI All Rights Reserved. 24 Old Kings Road North Palm Coast, FL appraiserschoice.com ACI Sketch Copyright October 2008, ACI All Rights Reserved 24 Old Kings Road North Palm Coast, FL 32137 appraiserschoice.com 800.234.8727 ACI Sketch Contents Getting Started 1 Working with the Grid 2 Unit

More information

Mid_Term_Review_PhotoShop_Design Test B Name

Mid_Term_Review_PhotoShop_Design Test B Name Mid_Term_Review_PhotoShop_Design Test B Name Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Photoshop uses a mathematical process called when it changes

More information

Computer Tools for Data Acquisition

Computer Tools for Data Acquisition Computer Tools for Data Acquisition Introduction to Capstone You will be using a computer to assist in taking and analyzing data throughout this course. The software, called Capstone, is made specifically

More information

Photoshop CC Editing Images

Photoshop CC Editing Images Photoshop CC Editing Images Rotate a Canvas A canvas can be rotated 90 degrees Clockwise, 90 degrees Counter Clockwise, or rotated 180 degrees. Navigate to the Image Menu, select Image Rotation and then

More information

Getting Started. Right click on Lateral Workplane. Left Click on New Sketch

Getting Started. Right click on Lateral Workplane. Left Click on New Sketch Getting Started 1. Open up PTC Pro/Desktop by either double clicking the icon or through the Start button and in Programs. 2. Once Pro/Desktop is open select File > New > Design 3. Close the Pallet window

More information

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s LSM 5 MP, LSM 510 and LSM 510 META M i c r o s c o p y f r o m C a r l Z e i s s Quick Guide Laser Scanning Microscopes LSM Software ZEN 2007 August 2007 We make it visible. Contents Page Contents... 1

More information

Image Viewing. with ImageScope

Image Viewing. with ImageScope Image Viewing with ImageScope ImageScope Components Use ImageScope to View These File Types: ScanScope Virtual Slides.SVS files created when the ScanScope scanner scans glass microscope slides. JPEG files

More information