Model 30/L/0. Model 30/S/0. Shortl Blades, 0 Deflection 3/4" Spacing. Model 35/S/0 Short Blades, 0 Deflection 1/2" Spacing

Size: px
Start display at page:

Download "Model 30/L/0. Model 30/S/0. Shortl Blades, 0 Deflection 3/4" Spacing. Model 35/S/0 Short Blades, 0 Deflection 1/2" Spacing"

Transcription

1 model 30 / 35 - Steel Return Grilles & Registers 0 Deflection 0 fixed blade deflection maximizes free area for low pressure loss and sound levels Potential line of sight into duct thru grille is acceptable Model 30/S/0 using heavy, 20 gauge steel frames Aerodynamic blade design resulting in lowest achievable sound and pressure levels lades selected as horizontal or vertical for Model 30/L/0 Model 30/S/0 Shortl lades, 0 Deflection Model 35/S/0 Short lades, 0 Deflection Model 30/L/0 Long lades, 0 Deflection Model 35/L/0 Long lades, 0 Deflection Model 30 / S / 0 Model 35 / S / 0 0 Short lades Model 30 / L / 0 Model 35 / L / 0 0 Long lades NOM DUCT - 11/16 1-1/4 1 LADE VOLUME DAMPER 3-1/4-3

2 model 30 / 35 - Steel Return Grilles & Registers 45 Deflection 45 fixed blade deflection eliminates line of sight into ductwork Model 30/S/45 using heavy, 20 gauge steel frames NO SIGHT D E SIG N lades selected as horizontal or vertical for Model 30/L/45 Model 30/S/45 Shortl lades, 45 Deflection Model 35/S/45 Short lades, 45 Deflection Model 30/L/45 Long lades, 45 Deflection Model 35/L/45 Long lades, 45 Deflection Model 30 / S / D Model 35 / S / D 45 Vertical Louvers Model 30 / L / D Model 35 / L / D 45 Horizontal Louvers 1 1 1/4 NOM DUCT - 11/16 3-1/4 LADE VOLUME DAMPER -4

3 model 30 / 35 - Aluminum Return Grilles & Registers 0 Deflection 0 fixed blade deflection maximizes free area for low pressure loss and sound levels Potential line of sight into duct thru grille is acceptable Model 30/S/0 using corrosion resistant aluminum materials Aerodynamic blade design resulting in lowest achievable sound and pressure levels lades selected as horizontal or vertical for Model 30/L/0 Model 30/S/0 Shortl lades, 0 Deflection Model 35/S/0 Short lades, 0 Deflection Model 30/L/0 Long lades, 0 Deflection Model 35/L/0 Long lades, 0 Deflection Model 30 / S / 0 Model 35 / S / 0 0 Vertical Louvers Model 30 / L / 0 Model 35 / L / 0 0 Horizontal Louvers NOM DUCT - 11/ /32 1-3/8 LADE VOLUME DAMPER 3-5/8-5

4 model 30 / 35 - Aluminum Return Grilles & Registers 45 Deflection 45 fixed blade deflection eliminates line of sight into ductwork Model 30/S/45 using corrosion resistant aluminum materials NO SIGHT D E SIG N lades selected as horizontal or vertical for Model 30/L/45 Model 30/S/45 Shortl lades, 45 Deflection Model 35/S/45 Short lades, 45 Deflection Model 30/L/45 Long lades, 45 Deflection Model 35/L/45 Long lades, 45 Deflection Model 30 / S / 45 Model 35 / S / Vertical Louvers Model 30 / L / 45 Model 35 / L / Horizontal Louvers NOM DUCT - 15/ /32 1-3/8 3-5/8 LADE VOLUME DAMPER -6

5 model AC Lay-In Ceiling Return Grilles of room air Where reduced border width is preferred over larger surface frame 45 fixed blade deflection eliminates line of sight into ductwork. 0 straight blade maximizes core area Designed for use in conventional 15/16" inverted T-bar or 9/16" narrow slot type suspended ceiling grid systems Reduced order! registers exceeding the industry standard using heavy steel or extruded aluminum frames 1/2" or 3/4" blade spacing lades are parallel to long dimension opposed blade volume control damper satin polish finish volume control dampers Light shield for ceiling plenum return applications LAY-IN T-AR MODEL W/STEEL O W /ALUM. O Model AC30L-45 LAY-IN T-AR 9/16" NARROW SLOT 3/4" SPACING 1/2" SPACING 3/4" SPACING 1/2" SPACING 45 DEFL. 0 DEFL. 45 DEFL. 0 DEFL. 45 DEFL. 0 DEFL. 45 DEFL. 0 DEFL. AC30L-45 AC30L-0 AC35L-45 AC35L-0 AC30D-45 AC30D-0 AC35D-45 AC35D-0 AC30L-45-DS AC30L-0-DS AC35L-45-DS AC35L-45-DS AC30D-45-DS AC30D-0-DS AC35D-45-DS AC35D-0-DS AC30L-45-DA AC30L-0-DA AC35L-45-DA AC35L-45-DA AC30D-45-DA AC30D-0-DA AC35D-45-DA AC35D-0-DA MODULE SIZE MODEL SAC3LOD / XAC3LOD (Shown) = MODULE SIZE - 1 MODEL SAC3LOS / XAC3LOS (Shown) LADE DAMPER 3-3/4 OPEN 45 CORE 0 CORE 1-15/32 23/32 TYP. 3/4 TYP 3/4 TYP NOM MODULE SIZE - 1/4 AVAILALE MODULE SIZES 12 X X X X 48 Note: lades are Parallel to Longer Dimension as Standard 9/16 NARROW SLOT SNAP-IN -8

6 model E30 Enhanced Capacity Returns 45 Deflection Enhanced blade design for high capacity applications Limited line of sight into duct is acceptable Typically surface installed in the side wall, duct, or ceiling Available in steel using heavy, 20 gauge steel frames, or corrosion resistant aluminum materials 45 fixed blade deflection, 3/4 spacing lades selected as horizontal or vertical for for supplied #8 x 1-1/2 oval head screws Aluminum opposed blade volume control dampers Model E30/L/45 Vertical lades, 45 Deflection Model E30/S/45 Horizontal lades, 45 Deflection -16

GRILLE AND REGISTER OPTIONS AND ACCESSORIES

GRILLE AND REGISTER OPTIONS AND ACCESSORIES GRILLE ND REGISTER OPTIONS ND CCESSORIES PRODUCT OVERVIEW OPTIONS ND CCESSORIES FOR FSTENING ND MOUNTING FRMES Up to four methods of fastening available for most models. Sub-frame available for professionally

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES Model 49-240 Model 48LL1 Model 49-280 Model 49-480 Model 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance.

More information

AMDL - Aluminum Linear Louver Face Diffuser Submittal Sheet OVERALL DIFFUSER = NOM. + 5.750 (146) NECK OVERALL = NOM. -.125 (3) NOM. DCUT OVERALL DIFFUSER = NOM. + 5.750 (146) 2.094 (53) TYPE 1 SURFACE

More information

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW GENERL PROUCT OVERVIEW Ceiling iffusers Quality ssured Products, unobtrusive clean lines for appearance, careful engineering and professional workmanship with the backing of an industry leader - these

More information

LINEAR GRILLES AND REGISTERS

LINEAR GRILLES AND REGISTERS LINEAR GRILLES AND REGISTERS Linear Grille ( Continuous type ) Linear Grille ( Flange type ) Linear Curved Grille INTRODUCTION COSMOS Linear Grilles and Registers covers a wide range for supply and return

More information

LINEAR AIR GRILLE LF - 202/LF 212 / LF / LF ACCESSORIES

LINEAR AIR GRILLE LF - 202/LF 212 / LF / LF ACCESSORIES TYPE LF - 202/LF 212 / LF 202-2 / LF 212-2 LINEAR AIR GRILLE ACCESSORIES DESCRIPTION The linear air grilles of LF-202, LF-212 series are suitable for installation on walls, ducts and false ceilings. The

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Airfoil Blade Return Air Models 71FH, 7145H 45 Deflection, 3/4" (19) Blade Spacing The airfoil blades are fixed at a 45 angle. This grille is vision proof when installed in a low or high sidewall location

More information

NOTES: Dimensions in parentheses are mm. For 1600 grille length and width dimensional information, see table on page K1-25.

NOTES: Dimensions in parentheses are mm. For 1600 grille length and width dimensional information, see table on page K1-25. K, / Blade Thickness Dimensional Information & Frame Styles, FACE VIEW FOR FRAME STYLES A, B, C, AE, BE, CE, DS, & RG 7/" (22) 9" (229) MAX For grille length and width dimensional information, see table

More information

Submittal Sheet COUNTERSUNK HOLES SDG SPIRAL DUCT GRILLE 1 7/8" (47) + 1 1/4" (32) - 3/4" (19) ( DUCT OPENING ) END GASKET NOM. LENGTH - 3/4" (19) OPTIONAL AIR SCOOP AIR SCOOP (ROD OPERATOR) NOM. LENGTH

More information

INSTALLATION & OPERATION MANUAL ML-37 / ML-38 / ML-39 MLR-37 / MLR-38 / MLR-39. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL ML-37 / ML-38 / ML-39 MLR-37 / MLR-38 / MLR-39. Redefine your comfort zone. INTALLATION & OPERATION MANUAL ML-37 / ML-38 / ML-39 MLR-37 / MLR-38 / MLR-39 IOM Linear lot Ceiling Diffusers Factory Cut upply ML-37 ML-38 ML-39 Factory Cut Return MLR-37 MLR-38 MLR-39 Factory pacer

More information

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System. SECTION 15910 DUCT ACCESSORIES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15890 - Ductwork. 2. 15900 - Controls and Instrumentation. 3. 15940 - Outlets (HVAC). 4. 15970 - HVAC Control System.

More information

Document Number ODFD-XXX and OFD-XXX Series Installation Drawings for Out of Wall Curtain Fire Dampers

Document Number ODFD-XXX and OFD-XXX Series Installation Drawings for Out of Wall Curtain Fire Dampers Document Number 481329 ODFD-XXX and OFD-XXX Series Installation Drawings for Out of Wall Curtain Fire s Approved installations for curtain fire dampers 1) Through the grille access and 2) Installation

More information

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing. SECTION 15841 LOW PRESSURE STEEL DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15180 - Mechanical Systems Insulation. 2. 15940 - Outlets (HVAC). 3. 15991 - Testing and Balancing. 1.02 SUBMITTALS

More information

SCD, ASCD Square Cone Diffuser CM = CEILING MODULE CEILING OPENING D = DUCT SIZE. OD = D - 1/8" (3mm)

SCD, ASCD Square Cone Diffuser CM = CEILING MODULE CEILING OPENING D = DUCT SIZE. OD = D - 1/8 (3mm) SCD, ASCD Square Cone Diffuser CM = CEILING MODULE CEILING OPENING D = DUCT SIZE OD = D - 1/8" (3mm) MIN. 1" (25mm) A Optional 4th Cone STANDARD CONSTRUCTION: SCD - Steel construction ASCD - Aluminum construction

More information

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section. SECTION 23 31 13 METAL HVAC DUCTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in

More information

Technical Data VARIABLES

Technical Data VARIABLES Overview SYSTEM Rulon Panel Grilles are manufactured with aligned and spaced wood strips suspended vertically or horizontally, giving a ladder-like appearance. Panel Grilles provide a modern or traditional

More information

MANUAL INSTALLATION. Linear Bar Grille LBP. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Linear Bar Grille LBP. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Linear Bar Grille LBP v000 Issue Date: 09/17/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Overview...1 Before You Start...1 Getting Started...1

More information

HALL 1 & HALL 4 RESTROOM FINISH UPGRADE 100 SOUTH WEST TEMPLE, SLC, UT QUOTE # SLP42848 AUGUST 29, 2017 CONSTRUCTION DOCUMENTS ABBREVIATIONS

HALL 1 & HALL 4 RESTROOM FINISH UPGRADE 100 SOUTH WEST TEMPLE, SLC, UT QUOTE # SLP42848 AUGUST 29, 2017 CONSTRUCTION DOCUMENTS ABBREVIATIONS DRAWING INDEX HALL 1 & HALL 4 BID INFORMATION RESTROOM 100 SOUTH WEST TEMPLE, SLC, UT 84111 QUOTE # SLP42848 AUGUST 29, 2017 CONSTRUCTION DOCUMENTS ABBREVIATIONS CONSULTANTS OWNER SYMBOL LEGEND VICINITY

More information

SECTION AIR DISTRIBUTION SYSTEM

SECTION AIR DISTRIBUTION SYSTEM SECTION 23 30 00 AIR DISTRIBUTION SYSTEM PART 1 - GENERAL 1.1 Scope of Work: The work covered by this section consists of providing all labor, equipment and materials and performing all operations necessary

More information

REQUEST FOR INFORMATION

REQUEST FOR INFORMATION Ardmore, PA Atlantic City, NJ REQUEST FOR INFORMATION PROJECT: 1845 - Renaissance Hotel Renovations RFI NUMBER: 10.0 JONATHAN NEHMER & ASSOC ATTN: Lauren Maccherone Dacey 7361 Calhoun Place Suite 310 Rockville,

More information

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows. SECTION 233100 DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insulation shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation

More information

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe Markers. 2. Valve Tags. 3. Equipment Nameplates. 4. Underground Marking Tape. 5. Duct

More information

METALWORKS TARTAN PANELS General Installation Instructions

METALWORKS TARTAN PANELS General Installation Instructions CEILING SYSTEMS METALWORKS TARTAN PANELS General Installation Instructions 1. GENERAL 1.1. Product Description MetalWorks Tartan system is a combination of metal ceiling panels available in a range of

More information

Technical Development Program

Technical Development Program Technical Development Program COMMERCIAL DISTRIBUTION SYSTEMS PRESENTED BY: Ray Chow Duct Design Level 1 Fundamentals Sales Engineer Menu Section 1 Section 2 Section 3 Section 4 Section 5 Introduction

More information

INSTALLATION, I O OPERATION & MAINTENANCE M A N U A L. Flowline. Architectural Linear Diffusers

INSTALLATION, I O OPERATION & MAINTENANCE M A N U A L. Flowline. Architectural Linear Diffusers INSTALLATION, I O M OPERATION & MAINTENANCE M A Flowline Architectural Linear Diffusers N U A L FLH Series: Horizontal High Throw FLV Series: Vertical Jet Throw www.nailor.com INSTALLATION INSTRUCTIONS

More information

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Linear Bar Grille - Heavy Duty LBPH/LBMH v000 Issue Date: 09/17/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Overview...1 Before You Start...2

More information

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section. SECTION 15800! AIR DISTRIBUTION PART 1! GENERAL 1.01 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this

More information

Mast Solutions Document/Installation Manual

Mast Solutions Document/Installation Manual Mast Solutions Document/Installation Manual The Mast family from Veritas is the perfect answer to movable and stationery partitions and room dividers, and hinged doors. This system is extremely versatile

More information

REGISTERS, GRILLES & DIFFUSERS

REGISTERS, GRILLES & DIFFUSERS 2012 REGISTS, GRILLES & DIFFUSS AUTHORIZED DISTRIBUTOR LIST PRICING HCPL-42 rev3 EFFECTIVE: JAN 9, 2012 REGISTS, GRILLES & DIFFUSS TMS & CONDITIONS SALE OF ALL GOODS ARE EXPRESSLY CONDITIONED UPON THE

More information

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L I NSTA LL AT IO N & OPER AT I ON M AN UA L FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I OM F L-1 0/ FL- 15 /FL-20 /FL-25/FL-3 0 FlowBar Installed During Hard Ceiling

More information

IOM 005 Effective 1/13/18 Rev E A I R D I S T R I B U T I O N

IOM 005 Effective 1/13/18 Rev E A I R D I S T R I B U T I O N IOM 005 Effective 1/13/18 Rev E A I R D I S T R I B U T I O N L i n e a r S l o t D i f f u s e r s M o d e l s S L A D / F r e e F l o / P r o J e t I n s t a l l a t i o n O p e r a t i o n a n d M a

More information

Safety Glasses Work Gloves Chop Saw with Cutting Disk. Half Round File Pencil Marker

Safety Glasses Work Gloves Chop Saw with Cutting Disk. Half Round File Pencil Marker ATLANTIS RAIL Contact Information: Atlantis Rail Systems 70 Armstrong Road 3900 Civic Center Drive Plymouth, MA 02360 North Las Vegas, NV 89030 (800) 541-6829 or (508) 732-9191 (508) 732-9798 www.atlantisrail.com

More information

最終校 08_ スケール.indd 260

最終校 08_ スケール.indd 260 170 180 190 200 210 220 230 0 240 260 270 280 290 300 300mm 260p 260p 260p 261p 261p 262p 262p 263p 8 2/33m 6 7 4 3 1/33m 2 264p 264p 5 263p 265p 1 1/33m 3 4 266p 265p 2 265p 266p 1 0 直尺 5 268p 267p 3

More information

PENDANT MOUNT - DIRECT

PENDANT MOUNT - DIRECT Project Type Louver Notes Flush Spotless Lens - down Glo Lens - up Glo Lens up and down PERFORMANCE PER LINEAR FOOT AT 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY SHIELDING 1000 lm/ft 9.9 W/ft 97

More information

baldwin 5" High, Solid Brass Solid Brass

baldwin 5 High, Solid Brass Solid Brass Tel (45) 552-5500 www.macpac.com DOOR KNOCKERS BALDWIN door knockers BALDWIN HOUSE NUMBERS 5" High, baldwin COLONIAL 6.5" x 3.5" C/C of bolts: 4" Available w/observ-o-scope* 002-003 Lifetime Pol. Brass

More information

FLOWLINE LINEAR DIFFUSERS

FLOWLINE LINEAR DIFFUSERS FLOWLINE LINER DIFFUSERS 1 FLOWLINE LINER DIFFUSERS Contents Overview of FlowLine System Continuous FlowLine Linear FL Series orizontal igh Throw Pattern Controllers FLV Series Vertical Jet Throw Pattern

More information

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals

PEDESTAL INSTALLATION. Guidelines for installing adjustable height pedestals BASIC REQUIREMENTS Irrespective of the type of pavers or tiles that will be installed over pedestals, the following basic requirement must be met. Decks must be designed not to exceed the load capacity

More information

ENR# Enlighted remote (5) WC# wireless control dimming. Specify quantity. Requires 8" blank See integrated controls guide for more details.

ENR# Enlighted remote (5) WC# wireless control dimming. Specify quantity. Requires 8 blank See integrated controls guide for more details. Project Type Notes 0.25" Glo lens PERFORMANCE PER LINEAR FOOT AT 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY SHIELDING 1000 lm/ft 9.9 W/ft 97 lm/w L Please consult factory for custom lumen output

More information

INTERIOR INSTALLATION

INTERIOR INSTALLATION 6" TWO (2) #6 FASTENERS BY OTHERS, NOT BY HUNTER DOUGLAS, TYP. MAIN TEE PER ASTM C635, BY OTHERS, TYP. 2" HANGER BRACKET ASSEMBLY PRIME BEAM* 2" MAX MAIN TEE T-GRID PER ASTM C635 BY OTHERS SEE DETAIL A.2

More information

CEILING HI-OUTPUT. Project. Type. Notes

CEILING HI-OUTPUT. Project. Type. Notes Project Type Notes PERFORMANCE/LINEAR FT AT 3000K AND 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY* 3 9/16 700 lm/ft 7.9 W/ft 89 lm/w 900 lm/ft 10.6 W/ft 85 lm/w 1100 lm/ft 13.5 W/ft 81 lm/w 1 5/8"

More information

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation. metalworks Plank Assembly and Installation Instructions 1. GENERAL is a ceiling system made up of standard sized hook-on planks fabricated from galvanized steel and powder coated to provide a damage and

More information

INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R

INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R I. SUSPENDED INSTALLATIONS 1. Lay the two track halves on the floor with

More information

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT SECTION 23 05 53 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Plastic Nameplates 2. Tags 3. Plastic Pipe Markers 4. Ceiling Tags 5. Detectable Underground Tape 6. Stencils PART 2 - PRODUCTS 2.1 MANUFACTURERS

More information

WALL HI-OUTPUT. Project. Type. Notes

WALL HI-OUTPUT. Project. Type. Notes Project Type Notes PERFORMANCE/LINEAR FT AT 3000K AND 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY* 3 9/16 700 lm/ft 7.3 W/ft 96 lm/w 900 lm/ft 9.8 W/ft 92 lm/w 1100 lm/ft 12.5 W/ft 88 lm/w 1 5/8"

More information

1x lm/ft - Maximum K

1x lm/ft - Maximum K Pixel 1x4 shown Project Type Notes Pixel 2x2 Pixel 1x4 Pixel 2x2 shown Pixel 1x8 shown 2 29/32 5 13/16 Pixel 2x2 Pixel 1x4 / 1x8 3 5/32 4" 4" 1 module contains 4 MikroLite cells Pixel 1x8 3 13/16 11 5/8

More information

Siding Systems NOVIKSTONETM DS DRY STACK STONE INSTALLATION GUIDE

Siding Systems NOVIKSTONETM DS DRY STACK STONE INSTALLATION GUIDE Siding Systems NOVIKSTONETM DS DRY STACK STONE GENERAL INFORMATION CAUTION: REMEMBER THAT POLYMER UNDERGOES EXPANSION/CONTRACTION DUE TO VARIATIONS IN TEMPERATURE. THE FOLLOWING INSTRUCTIONS WILL ALLOW

More information

CEILING HI-OUTPUT. Project. Type. Notes

CEILING HI-OUTPUT. Project. Type. Notes Project Type Notes PERFORMANCE/LINEAR FT AT 3000K AND 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY* 3 9/16 700 lm/ft 7.9 W/ft 89 lm/w 900 lm/ft 10.6 W/ft 85 lm/w 1100 lm/ft 13.5 W/ft 81 lm/w 1 5/8"

More information

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available: Application: Tag: Project: Location: Date: Engineer: Contractor: Architect: Submitted by: The ABV Automatic maintains a constant airflow volume in HVAC applications. The highly engineered damper blade

More information

KCR-R CONSTANT AIR VOLUME FLOW REGULATOR

KCR-R CONSTANT AIR VOLUME FLOW REGULATOR KCR-R CONSTANT AIR VOLUME FLOW REGULATOR Intended use: The regulator can be used in both intake and exhaust ventilation ducts. Made of M1 class plastic. Operating range up to 60 C Desription: The constant

More information

CIRCULAR VAV UNITS - CVA

CIRCULAR VAV UNITS - CVA CIRCULAR VAV UNITS - CVA DESCRIPTION & FEATURES Circular VAV (Variable Air Volume) boxes are suitable for room temperature control in low, medium and high pressure installations. Units are suitable for

More information

Looking for a small band saw? The Ellis 1100 band saw might be just what you are looking for.

Looking for a small band saw? The Ellis 1100 band saw might be just what you are looking for. 1100 MITRE BAND SAW Looking for a small band saw? The Ellis 1100 band saw might be just what you are looking for. This portable band saw moves easily to the job site. Use it as horizontal or vertical saw.

More information

Architectural. 1 Paralum by Jean Nouvel

Architectural. 1 Paralum by Jean Nouvel IN Architectural 1 Paralum by Jean Nouvel Luxiona and Jean Nouvel have joined forces to create Paralum, an exclusive, innovative comprehensive ceiling and surround lighting system. Paralum is a new system

More information

Lamp type 17 17W T8 (24") 14T5 14W T5 (22") 24T5HO 24W T5 (22") CF40 40W TT5 (24") CF50 50W TT5 (24")

Lamp type 17 17W T8 (24) 14T5 14W T5 (22) 24T5HO 24W T5 (22) CF40 40W TT5 (24) CF50 50W TT5 (24) Recessed Direct/Indirect Lighting Avante 2' X 2' 2 x 2 Symmetric,MDR Intended Use Originally developed for the small private office, Avante 2x2 fixtures also are effective in corridors, libraries and food-service

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION SECTION 15190 MECHANICAL IDENTIFICATION PART 1 GENERAL 1.01 SECTION INCLUDES A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe Markers. 1.02 SUBMITTALS A. Submit valve chart and schedule,

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

IBD23 CURTAIN TYPE STATIC FIRE DAMPERS 3 HOUR UL555 RATED FOR USE IN STATIC SYSTEMS

IBD23 CURTAIN TYPE STATIC FIRE DAMPERS 3 HOUR UL555 RATED FOR USE IN STATIC SYSTEMS 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 ID23 CURTIN TYPE STTIC FIRE DMPERS 3 OUR UL555 RTED FOR USE IN STTIC SYSTEMS pplication Ruskin Model ID23 3 hour UL classified

More information

JAMESTOWN175 SERIES Fixed, Projected and Casement Steel Windows

JAMESTOWN175 SERIES Fixed, Projected and Casement Steel Windows Fixed, Projected and Casement Steel Windows Hope s Jamestown Series steel windows are manufactured from heavy custom hot-rolled steel profiles. All frames, ventilators and muntin bars are -/" in depth.

More information

Inc. BT Series. BW Series

Inc. BT Series. BW Series Inc. 2013 BT Series BW Series Inc. Fast Installation One of the prime features of the RangeRack cable tray design is that the channel-style siderails accept spring nuts. This eliminates the need for any

More information

Wall mounting with holding profile

Wall mounting with holding profile B Main profile C Edge profile D Wall spacer E Heradesign acoustic panel Edge distance max. 250 mm c Centre distance of basic section (see table) B max. 600 mm or 625 mm a Centre distance of spacer (see

More information

S.NO Description Quantity Rate Amount

S.NO Description Quantity Rate Amount INTERIOR WORKS NANDIMANDALAM BRANCH S.NO Description Quantity Rate Amount 1 Full height partition with laminate finish and glass. Providing & fixing partly glazed partly paneled Dry Wall Partition with

More information

Classic Exposed Tee System (24" x 24", 24" x 48", and 24" x 72") Floating Clouds and Perimeter Wall Attachment

Classic Exposed Tee System (24 x 24, 24 x 48, and 24 x 72) Floating Clouds and Perimeter Wall Attachment Ceiling Systems SERPENTINA Classic Exposed Tee System (24" x 24", 24" x 48", and 24" x 72") Floating Clouds and Perimeter Wall Attachment Installation Instructions The 3-Dimensional Ceiling System consists

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 27 = LED 2700K 30 = LED 3000K 35 = LED 3500K 40 = LED 4000K

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 27 = LED 2700K 30 = LED 3000K 35 = LED 3500K 40 = LED 4000K DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

REALLY EZ MAGNETIC DUCT SCRAPER TM

REALLY EZ MAGNETIC DUCT SCRAPER TM CONGRATULATIONS ON YOUR PURCHASE OF OUR PATENTED US Patent No. 7437794 REALLY EZ MAGNETIC DUCT SCRAPER TM The time and money you SAVE using it will astound you! INSTRUCTION GUIDE ATTACHED PLEASE READ AND

More information

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION CAUTION: BEFORE BEGINNING INSTALLATION REVIEW LAYOUT DRAWINGS, AND SHIPMENT. MAKE SURE ALL LIGHT S AND MATERIALS ARE ON SITE AND READILY ACCESSIBLE. IF ANY ICON MATERIALS ARE MISSING, CONTACT ICON INTERNATIONAL

More information

COLIBRI Ceiling. Square ceiling diffuser with discs for supply air QUICK FACTS

COLIBRI Ceiling. Square ceiling diffuser with discs for supply air QUICK FACTS Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed

More information

ORDERING INFORMATION:

ORDERING INFORMATION: LINEAR GRUV1. APPLICATION: Retail and commercial recessed ambient lighting CONSTRUCTION: Extruded aluminum housing and trim Die-formed, cold-rolled steel internal components and external housing OPTICS:

More information

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version CEILING SYSTEMS Between us, ideas become reality Installing Suspended Ceilings International Version 1 Installing Armstrong Suspended Ceilings An Armstrong suspended mineral fiber ceiling is functional,

More information

metalworks Vector Assembly and Installation Instructions

metalworks Vector Assembly and Installation Instructions metalworks Vector Assembly and Installation Instructions 1. GENERAL 1.1 Product Description MetalWorks Vector is a downward accessible galvanized steel ceiling panel available in standard 24" x 24" size.

More information

PENDANT MOUNT - DIRECT/INDIRECT

PENDANT MOUNT - DIRECT/INDIRECT Project Type Notes PERFORMANCE PER LINEAR FOOT AT 3500K CABLE 2 1 /4 STEM 2 1 /4 NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY UPLIGHT DOWNLIGHT 650 lm/ft 400 lm/ft 8.35 W/ft 125 lm/w Please consult factory

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm mm

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm mm DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty [38mm] 2.71" [69mm]

Catalog # Project. Comments. Prepared by. Warranty Five year warranty [38mm] 2.71 [69mm] DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

WALL MOUNT - DIRECT/INDIRECT. Project. Type. Notes

WALL MOUNT - DIRECT/INDIRECT. Project. Type. Notes Project Type Notes 2 1 /4 PERFORMANCE PER LINEAR FOOT AT 3500K NOMINAL LUMEN OUTPUT INPUT WATTS* EFFICACY UPLIGHT DOWNLIGHT 650 lm/ft 400 lm/ft 8.35 W/ft 125 lm/w Please consult factory for custom lumen

More information

VISIONGUARD LOUVERS INSTALLATION MANUAL

VISIONGUARD LOUVERS INSTALLATION MANUAL VISIONGUARD LOUVERS INSTALLATION MANUAL WWW.ROOFSCREEN.COM Toll Free 866 766 3727 Introduction... 2 This manual... 2 Application... 2 System Overview... 2 Components... 2 Louver Blades... 2 Louver Clip...

More information

finish AP alu. paint D custom UNV * *Please consult factory

finish AP alu. paint D custom UNV * *Please consult factory PROJECT INFORMATION Project: Type: Notes: REVIT files are available for download at SHOWN WITH LENS OPTION PRODUCT ORDERING CODE product id light dist. optics direct optics indirect length/ft lamp lamp

More information

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700 SECTION 23 3113 - LOW PRESSURE DUCTWORK PART 1 - GENERAL 1.1 SCOPE OF WORK: A. The work required under this section includes all work necessary for a complete installation of ductwork and accessories.

More information

COLIBRITM. Ceiling. Square ceiling diffuser with discs for supply air. Quick guide

COLIBRITM. Ceiling. Square ceiling diffuser with discs for supply air. Quick guide COLIBRITM Ceiling Square ceiling diffuser with discs for supply air Quick facts Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the exhaust

More information

21 C SHELVING SYSTEMS 21 C Shelving Systems consist of innovative products that provide visually appealing shelving and storage to any area. This syst

21 C SHELVING SYSTEMS 21 C Shelving Systems consist of innovative products that provide visually appealing shelving and storage to any area. This syst 21 C SHELVING SYSTEMS 21 C SHELVING SYSTEMS 21 C Shelving Systems consist of innovative products that provide visually appealing shelving and storage to any area. This system is available in two unique

More information

Product Selection Guide

Product Selection Guide Selection Guide GLAZING PRODUCTS DOOR LOUVERS VISION FRAMES D o o r P r o d u c t s 4958 Stout Dr. #119 San Antonio, TX 78219 210.662.6300 Fax 210.662.2828 E-mail door@anemostat www.anemostat V I S I O

More information

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL AXIOM Classic Trim Assembly and Installation Instructions 1. GENERAL 1.1 Description Axiom Classic Trim is a perimeter trim system designed for use with a variety of Armstrong suspension systems. Classic

More information

Fire Rating 3 hours- hollow metal doors mounted singly 90 minutes- hollow metal and composite core wood fire doors 20 minutes- wood doors

Fire Rating 3 hours- hollow metal doors mounted singly 90 minutes- hollow metal and composite core wood fire doors 20 minutes- wood doors FM-300 Edge Mount 260 Santa Fe Street, Pomona, CA 91767 800-872-3267 909-632-2300 800-232-6752 fax www.markar.com Heavy-duty 14 Gauge stainless steel US32D Satin Stainless Steel (630) Grade 1 4'0" maximum

More information

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the merican Standard Code for Pressure Piping. For more information, see page 57 for Engineering Data and

More information

CHAPTER 6 DUCT SYSTEMS

CHAPTER 6 DUCT SYSTEMS CHAPTER 6 DUCT SYSTEMS 601.0 Scope General. 601.1 General Applicability. Ducts and plenums that are portions of a heating, cooling, absorption or evaporative cooling, or product-conveying system shall

More information

GENERAL ISOMETRIC LAYOUT

GENERAL ISOMETRIC LAYOUT EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE GATE LID CARBATHAN HG 0 WEB GRAY LOWER PAN GRATING ALUMINUM WIPER WALL CARBATHANE HG, 90 GRAY STRUCTURAL SPECIFICATIONS:. FLOODGATE MATERIAL TO BE ALUMINUM

More information

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the merican Standard Code for Pressure Piping. For more information, see page 57 for Engineering Data and

More information

Architectural Aluminum Frames

Architectural Aluminum Frames Specialty requirements for room identification and control are accomplished with these unique frames. They feature built-in changeable messages, magnetic changeable signs and frames with dividers. Frames

More information

Built to Order. Stiles. StileLine. Steel Storefront. Features. Glass. Finishing. Section Contents

Built to Order. Stiles. StileLine. Steel Storefront. Features. Glass. Finishing. Section Contents Stiles Steel Door + Window Systems Steel Storefront Section Contents Tuck Glazed System SF-1.0 Flush Glazed System SF-2.0 Structural Glazed System SF-3.0 Pressure Glazed System SF-4.0 Operable Vents SF-5.0

More information

07 MECHANICAL 0746p IVR Natural ventilation and air grilles

07 MECHANICAL 0746p IVR Natural ventilation and air grilles 0746P IVR NATURAL VENTILATION AND AIR GRILLES Branded worksection This branded worksection Template has been developed by NATSPEC in conjunction with IVR Group and may be used whilst the Product Partner

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty. 51mm mm 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K

Catalog # Project. Comments. Prepared by. Warranty Five year warranty. 51mm mm 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

SECTION LOW PRESSURE DUCTWORK

SECTION LOW PRESSURE DUCTWORK SECTION 15841 LOW PRESSURE DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07270 - Firestopping and Fire and Smoke Barrier Caulking. 2. 15260 - Vibration Isolation. 3. 15280 - Thermal Insulation

More information

PENDANT MOUNT ASYMMETRIC

PENDANT MOUNT ASYMMETRIC PROJECT INFORMATION Project: Notes: Type: DIMENSIONS SECTION VIEWS Direct / Indirect Direct Indirect SHOWN WITH LENS OPTION ORDERING CODE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PRODUCT SPECIFICATIONS

More information

Panel Installation Instructions

Panel Installation Instructions EXTREMELY IMPORTANT INFORMATION PLEASE READ ENTIRE PACKET! Warranty Is Void If Panels Not Installed According to Instructions 1. WARNINGS & SPECIAL NOTES 1.1 Keep panels 24 from Heaters and shield Radiant

More information

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 6 152mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 6 152mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K DESCRIPTION The Define series by Neo-Ray characterizes the ultimate in minimalist simplicity by providing clean, uniform lines of illumination in virtually any architectural environment. Powered by s most

More information

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job: Catalog number: and Finish Options: See page 2 : See pages 3-5ˇ Approvals: Date: Page: 1 of 5 Specifications Lamp Housing: Die-cast brass with die-cast cover, stainless steel fasteners and stainless steel

More information

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Nameplates. B. Tags. C. Stencils. D. Pipe Markers. 1.2 RELATED REQUIREMENTS A. Section 099123 - Interior

More information

DA 22 Technical Specification

DA 22 Technical Specification 1/26 DA 22 DA 22-12-2615 DA 22-12-4112 DA 22-30-2630 DA 22-30-4128 2/26 Content 1. General Description... 3 2. Operating Data... 4 2.1. Operating Data 12V-Versions... 4 2.2. Operating Data 28V-Versions...

More information

Frameless Fixed Panel Slider

Frameless Fixed Panel Slider INSTALLATION INSTRUCTIONS Frameless Fixed Panel Slider QCI-5279 SINGLE ROLLER WITH ANTI-JUMP DOUBLE ROLLERS QCI5279 Rev Page Certified 08/09/6 Tools: To install your New Shower Enclosure, you may need

More information

Classics from Hart & Cooley is a decorator collection of high. quality registers, grilles and diffusers in classic designs and

Classics from Hart & Cooley is a decorator collection of high. quality registers, grilles and diffusers in classic designs and Classics from Hart & Cooley is a decorator collection of high quality registers, grilles and diffusers in classic designs and finishes. You will find Classics to be a unique, stylish alternative to everyday

More information

NK / NL series. Rectangular VAV and CAV air volume control terminals

NK / NL series. Rectangular VAV and CAV air volume control terminals NK / NL series Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model overview / dimensions 4-5 Sound data NKOAOOB / NLOAOOB

More information

UNIVERSITY SERIES Fixed, Projected and Casement Steel Windows

UNIVERSITY SERIES Fixed, Projected and Casement Steel Windows Fixed, Projected and Casement Steel Windows Hope's University Series steel window profiles were designed for projects requiring historic replication of exterior putty glazed steel windows. The fixed and

More information