3

4

5

6

7 Submittal Sheet COUNTERSUNK HOLES SDG SPIRAL DUCT GRILLE 1 7/8" (47) + 1 1/4" (32) - 3/4" (19) ( DUCT OPENING ) END GASKET NOM. LENGTH - 3/4" (19) OPTIONAL AIR SCOOP AIR SCOOP (ROD OPERATOR) NOM. LENGTH ( DUCT OPENING ) NOM. LENGTH + 2 7/8" (73) RECOMMENDED SDG SIZE FOR SPECIFIED DUCT DIAMETER DUCT SIZE MINIMUM MAXIMUM (DIAMETER) SIZE NOM.WIDTH SIZE 8" - 13" - 4" 14" - 21" 4" 6" 22" - 31" 4" 8" 32" - 41" 4" 10" 42" - OVER 4" 12" DAMPER OPTIONS: AS: AIR SCOOP (ROD OPERATOR) ASC: AIR SCOOP (CABLE OPERATOR) 3: VCS3 COATED STEEL OPPOSED BLADE DAMPER NOTES: INTENDED FOR USE IN SPIRAL OR ROUND DUCT APPLICATIONS (MINIMUM DUCT SIZE 8" (203) MINIMUM NOM. LENGTH IS 10" (254) MAXIMUM NOM. LENGTH IS 36" (914) MULLIONS ARE USED WHEN BLADE LENGTH EXCEEDS 24" AVAILABLE SIZE IN 1" INCREMENTS 3/4" BLADE SPACING OPEN CELL FOAM INSULATION PROVIDES A TIGHT SEAL AROUND THE GRILLE OPENING IN ANY ROUND DUCT (GREY STANDARD) OPTIONAL AIR-SCOOP AVAILABLE FACTORY TOLERANCE +/ 1/32" (1) GALVANIZED UNITS ARE MILL FINISH. STEEL AND GALVANIZED MODELS COME WITH GALVANIZED SCOOP. ALUMINUM MODEL COMES WITH MILL FINISH ALUMINUM SCOOP. BLADE ORIENTATION - FRONT SET: S L OPTIONAL AIR SCOOP PARALLEL TO SHORT DIM PARALLEL TO LONG DIM END GASKET COLOR OPTIONS: GREY WHITE BLACK AIR SCOOP (CABLE OPERATOR) MATERIAL: ST STEEL FRAME AND BLADES GV GALVANIZED STEEL FRAME AND BLADES AL ALUMINUM FRAME AND BLADES FINISH: B12 WHITE (ST & AL) (OTHER FINISHES AVAILABLE) GV MILL FINISH END GASKET PROJECT: ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. ENGINEER: SDG CUSTOMER: SPIRAL DUCT GRILLE SUBMITTAL DATE: SPEC. SYMBOL: DEC 2012 Copyright E.H.PRICE LIMITED 2005 ECN: SHEET 1 OF 1 REV G

8 SDGE - SPIRAL DUCT GRILLE EXTRUDED Submittal Sheet OPTIONAL AIR SCOOP OPTIONAL AIR SCOOP AIR SCOOP (ROD OPERATOR) 7/8" (22) AIR SCOOP (CABLE OPERATOR) VARIES WITH DUCT DIAMETER NOM. LENGTH - 5/8" (16) DUCT OPENING = NOM. LENGTH OVERALL = NOM. LENGTH + 1" (25) -1/4" (6) DUCT OPENING = 1" u1/8" (3) STANDARD CONSTRUCTION: FRAMES: EXTRUDED ALUMINUM BLADES: EXTRUDED ALUMINUM 3/4" BLADE SPACING DAMPER OPTIONS: AS: AIR SCOOP (ROD OPERATOR) ASC: AIR SCOOP (CABLE OPERATOR) 3: VCS3 COATED STEEL OPPOSED BLADE DAMPER AVAILABLE CONFIGURATIONS: DOUBLE DEFLECTION, FRONT BLADES PARALLEL TO LENGTH DOUBLE DEFLECTION, FRONT BLADES PARALLEL TO WIDTH SINGLE DEFLECTION, BLADES PARALLEL TO LENGTH SINGLE DEFLECTION, BLADES PARALLEL TO WIDTH FINISH: B12 WHITE (OPTIONAL FINISHES AVAILABLE) AC CLEAR ANODIZED FASTENING OPTIONS & ACCESSORIES: "A" MOUNTING STANDARD NOTES: NOMINAL LENGTHS AVAILABLE IN 1" INCREMENTS. FOR ONE-PIECE CONSTRUCTION: MIN. NOMINAL LENGTH = 6" MAX. NOMINAL LENGTH = 36" FACTORY TOLERANCE +/- 1/32" (1) PROJECT: Available Sizes Duct Dia. Nom. Widths x x 8 x x x 10 x x x x 12 x x x x x 14 x x x x x x 16 x x x x x x 18 x x x x x x 20 x x x x x x 22 x x x x x x 24 x x x x x x 26 x x x x x x 28 x x x x x x 30 x x x x x x 32 x x x x x x 36 x x x x x x ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. ENGINEER: CUSTOMER: SUBMITTAL DATE: SPEC. SYMBOL: DEC 2012 SDGE SPIRAL DUCT GRILLE EXTRUDED Copyright E.H.PRICE LIMITED 2007 ECN: SHEET 1 OF 1 REV E

9 SDGR SPIRAL DUCT GRILLE RETURN Submittal Sheet COUNTERSUNK HOLES 1 7/8 (47) + 1 1/4 (32) - 3/4 (19) ( DUCT OPENING ) NOM. LENGTH - 3/4 (19) NOM. LENGTH ( DUCT OPENING ) NOM. LENGTH + 2 7/8 (73) GASKET NOTES: RECOMMENDED SDGR SIZE FOR SPECIFIED DUCT DIAMETER DUCT SIZE MINIMUM MAXIMUM (DIAMETER) SIZE NOM.WIDTH SIZE 8" - 13" - 4" 14" - 21" 4" 6" 22" - 31" 4" 8" 32" - 41" 4" 10" 42" - OVER 4" 12" OPTIONS: GASKET GREY WHITE BLACK MATERIAL: ST STEEL GV GALVANIZED FINISH: B12 WHITE (ST) (OTHER FINISHES AVAILABLE) GV MILL FINISH PERFORATED GASKET INTENDED FOR USE IN SPIRAL OR ROUND DUCT APPLICATIONS (MINIMUM DUCT SIZE 8" (203) MINIMUM NOM. LENGTH IS 10" (254) MAXIMUM NOM. LENGTH IS 36" (914) AVAILABLE SIZE IN 1" INCREMENTS OPEN CELL FOAM INSULATION PROVIDES A TIGHT SEAL AROUND THE GRILLE OPENING IN ANY ROUND DUCT (GREY STANDARD) FACTORY TOLERANCE +/ 1/32" (1) GALVANIZED UNITS ARE MILL FINISH. PROJECT: ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. ENGINEER: SDGR CUSTOMER: SUBMITTAL DATE: SPEC. SYMBOL: MAR SPIRAL DUCT GRILLE RETURN Copyright E.H.PRICE LIMITED 2008 ECN: SHEET 1 OF 1 REV 0

10 SDGER - EXTRUDED SPIRAL DUCT RETURN GRILLE Submittal Sheet VARIES WITH DUCT DIAMETER 7/8" (22) STANDARD CONSTRUCTION: FRAMES: EXTRUDED ALUMINUM ALUMINUM PERFORATED FACE NOM. LENGTH - 5/8" (16) DUCT OPENING = NOM. LENGTH OVERALL = NOM. LENGTH + 1" (25) FINISH: B12 WHITE (OPTIONAL FINISHES AVAILABLE) AC CLEAR ANODIZED FASTENING OPTIONS & ACCESSORIES: "A" MOUNTING STANDARD NOTES: NOMINAL LENGTHS AVAILABLE IN 1" INCREMENTS. MIN. NOMINAL LENGTH = 6" MAX. NOMINAL LENGTH = 36" FACTORY TOLERANCE +/- 1/32" (1) -1/4" (6) DUCT OPENING = Available Sizes Duct Dia. Nom. Widths x x 8 x x x 10 x x x x 12 x x x x x 14 x x x x x x 16 x x x x x x 18 x x x x x x 20 x x x x x x 22 x x x x x x 24 x x x x x x 26 x x x x x x 28 x x x x x x 30 x x x x x x 32 x x x x x x 36 x x x x x x u1/8" (3) PROJECT: ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. ENGINEER: CUSTOMER: SUBMITTAL DATE: SPEC. SYMBOL: SEP 2008 SDGER SPIRAL DUCT GRILLE EXTRUDED RETURN Copyright E.H.PRICE LIMITED 2007 ECN: SHEET 1 OF 1 REV A

AMDL - Aluminum Linear Louver Face Diffuser Submittal Sheet OVERALL DIFFUSER = NOM. + 5.750 (146) NECK OVERALL = NOM. -.125 (3) NOM. DCUT OVERALL DIFFUSER = NOM. + 5.750 (146) 2.094 (53) TYPE 1 SURFACE

More information

GRILLE AND REGISTER OPTIONS AND ACCESSORIES

GRILLE AND REGISTER OPTIONS AND ACCESSORIES GRILLE ND REGISTER OPTIONS ND CCESSORIES PRODUCT OVERVIEW OPTIONS ND CCESSORIES FOR FSTENING ND MOUNTING FRMES Up to four methods of fastening available for most models. Sub-frame available for professionally

More information

LINEAR AIR GRILLE LF - 202/LF 212 / LF / LF ACCESSORIES

LINEAR AIR GRILLE LF - 202/LF 212 / LF / LF ACCESSORIES TYPE LF - 202/LF 212 / LF 202-2 / LF 212-2 LINEAR AIR GRILLE ACCESSORIES DESCRIPTION The linear air grilles of LF-202, LF-212 series are suitable for installation on walls, ducts and false ceilings. The

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES Model 49-240 Model 48LL1 Model 49-280 Model 49-480 Model 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance.

More information

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System. SECTION 15910 DUCT ACCESSORIES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15890 - Ductwork. 2. 15900 - Controls and Instrumentation. 3. 15940 - Outlets (HVAC). 4. 15970 - HVAC Control System.

More information

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available: Application: Tag: Project: Location: Date: Engineer: Contractor: Architect: Submitted by: The ABV Automatic maintains a constant airflow volume in HVAC applications. The highly engineered damper blade

More information

LINEAR GRILLES AND REGISTERS

LINEAR GRILLES AND REGISTERS LINEAR GRILLES AND REGISTERS Linear Grille ( Continuous type ) Linear Grille ( Flange type ) Linear Curved Grille INTRODUCTION COSMOS Linear Grilles and Registers covers a wide range for supply and return

More information

Stripmaster Wire Strippers

Stripmaster Wire Strippers D Stripmaster and Stripmaster Lite Wire Strippers One-step stripping enhances productivity Spring-action motion increases leverage and reduces operator fatigue Precision-ground, knife-type blades provide

More information

Ordering example: WSK-600 / B x H x L = 155 mm. M8 hexagon head screw, fixed by a locknut. Threaded bolt

Ordering example: WSK-600 / B x H x L = 155 mm. M8 hexagon head screw, fixed by a locknut. Threaded bolt Ordering example: / B x H x L = 155 mm P-3464/5595-MPA BS General / ordering example Dimensions B (width) x H (height) in mm (always corresponds to the clear shaft or smoke control damper dimensions) Available

More information

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME: Bol 8' 24' Round Tapered and Straight Wood Poles FIXTURE TYPE: PROJECT NAME: Round Taper Glulam solid wood and aluminum pole available in 8' 24' lengths. Tenon adapters, slip fitters and side bracket mounts

More information

Model 30/L/0. Model 30/S/0. Shortl Blades, 0 Deflection 3/4" Spacing. Model 35/S/0 Short Blades, 0 Deflection 1/2" Spacing

Model 30/L/0. Model 30/S/0. Shortl Blades, 0 Deflection 3/4 Spacing. Model 35/S/0 Short Blades, 0 Deflection 1/2 Spacing model 30 / 35 - Steel Return Grilles & Registers 0 Deflection 0 fixed blade deflection maximizes free area for low pressure loss and sound levels Potential line of sight into duct thru grille is acceptable

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Airfoil Blade Return Air Models 71FH, 7145H 45 Deflection, 3/4" (19) Blade Spacing The airfoil blades are fixed at a 45 angle. This grille is vision proof when installed in a low or high sidewall location

More information

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS ULTRA WINDOW & DOOR S AND RECEIVERS INSTALLATION INSTRUCTIONS! CAUTION: *REMEMBER SAFETY FIRST* Proper Eye and! Hearing Protection must always be worn during installation of all window and door products.

More information

IBD23 CURTAIN TYPE STATIC FIRE DAMPERS 3 HOUR UL555 RATED FOR USE IN STATIC SYSTEMS

IBD23 CURTAIN TYPE STATIC FIRE DAMPERS 3 HOUR UL555 RATED FOR USE IN STATIC SYSTEMS 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 ID23 CURTIN TYPE STTIC FIRE DMPERS 3 OUR UL555 RTED FOR USE IN STTIC SYSTEMS pplication Ruskin Model ID23 3 hour UL classified

More information

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing. SECTION 15841 LOW PRESSURE STEEL DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15180 - Mechanical Systems Insulation. 2. 15940 - Outlets (HVAC). 3. 15991 - Testing and Balancing. 1.02 SUBMITTALS

More information

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions Dimensions Class Bronze Dimensions Meets Ib. A.S.M.E. Stard Class 00 Bronze Dimensions Meets ANSI STD B. Nominal Dim. A O.D. Dim. B Circle Dim. C Hole No. Holes Nominal Dim. A Diam. Dim. B Min. Dim. C

More information

Walls Fact Sheets. Partition Walls and Walls Cladding. Perforated Board. Sandwich Board

Walls Fact Sheets. Partition Walls and Walls Cladding. Perforated Board. Sandwich Board s Partition and Perforated Board Sandwich Board Please consult Viroc Technical File available at www.viroc.pt, on EN language, on Downloads page. Other Viroc Recommended Solutions files, organized by type

More information

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)... INS-88.500-0A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE 1. Unpacking the KSCR... 2 2. Splicing the KSCR (If Required)... 4 3. Assemble Curb and Rail Corners... 5 4. Install Cross Bracing (If Required)...

More information

Light Structural Main Runner Light Structural Infill Tees. Straight Connector. Strut Structural Tee thread

Light Structural Main Runner Light Structural Infill Tees. Straight Connector. Strut Structural Tee thread Internal Splice Support Connector 85.6 Straight Connector 4.3 22.3 5.30 22.3 70.6 *Note: All Dimensions are in Millimeters U-Shape Connector, Hex Bolts, & Channel Nuts L-Angle Connector 9.7 3 8-6 for Light

More information

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR C1 Table of Contents 1, 15 51, 515 feature a neck mounted rotatable core with either a round or square neck. Aluminum or steel perforated face is, 5 R, supply, ceiling diffusers feature neck mounted curved

More information

SCD, ASCD Square Cone Diffuser CM = CEILING MODULE CEILING OPENING D = DUCT SIZE. OD = D - 1/8" (3mm)

SCD, ASCD Square Cone Diffuser CM = CEILING MODULE CEILING OPENING D = DUCT SIZE. OD = D - 1/8 (3mm) SCD, ASCD Square Cone Diffuser CM = CEILING MODULE CEILING OPENING D = DUCT SIZE OD = D - 1/8" (3mm) MIN. 1" (25mm) A Optional 4th Cone STANDARD CONSTRUCTION: SCD - Steel construction ASCD - Aluminum construction

More information

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS Sealing of fibrous glass duct board to the sheet metal sleeve must be made with glass fabric and mastic, except where operating pressure is less than

More information

NOTES: Dimensions in parentheses are mm. For 1600 grille length and width dimensional information, see table on page K1-25.

NOTES: Dimensions in parentheses are mm. For 1600 grille length and width dimensional information, see table on page K1-25. K, / Blade Thickness Dimensional Information & Frame Styles, FACE VIEW FOR FRAME STYLES A, B, C, AE, BE, CE, DS, & RG 7/" (22) 9" (229) MAX For grille length and width dimensional information, see table

More information

PIPE/CONDUIT SUPPORTS

PIPE/CONDUIT SUPPORTS PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120

More information

SCREW THREADS. = minor diameter. d 3. d 2. = pitch diameter

SCREW THREADS. = minor diameter. d 3. d 2. = pitch diameter ISO : 6 Part 2 DIN : Part /20 Metric (ISO) screw thread, coarse series -M- T-00 T-002 for M to incl. M,4, fit H/6h The bold lines indicate the maximum material profiles. The maximum material profile of

More information

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 36 WIREWAYS FOR RADIOLOGY EQUIPMENT SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable

More information

Round Duct and Fittings. Standards and Dimensional Data for Air Duct and Fittings

Round Duct and Fittings. Standards and Dimensional Data for Air Duct and Fittings Round Duct and Fittings Standards and Dimensional Data for Air Duct and Fittings www.airsidesheetmetal.com 973-786-6967(office) 973-786-6474(fax) Fabricated by Airside Sheet Metal Fabricators, Inc. - 2017

More information

Jabiru Installation instructions

Jabiru Installation instructions Page 1 of 5 s Step Description 1 Mark out centre line of the installation 2 Align centre line of installation with the centre line of the "Front Panel Cut out" template. Align "FLOOR" on template with

More information

PERIMETER SMOKE SEALS

PERIMETER SMOKE SEALS Trade Name: Raven Products Door Seals PERIMETER SMOKE SEALS Raven Door Seals : RP120 : RP150 : RP10Si : RP24Si : RP47Si : RP78Si : RP84Si : RP93Si : RP94Si Raven Door Sealing Systems are available to combat

More information

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS SECTION 15062 NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS For best results, display hidden notes to specifier. PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe supports. B. Conduit supports. C. Duct supports,

More information

Framing Components. Spacers, Gaskets, Cladding. Framing, Spacers & Cladding Pages

Framing Components. Spacers, Gaskets, Cladding. Framing, Spacers & Cladding Pages Framing Components CURRENT LOGO Spacers, Gaskets, Cladding Framing, Spacers & Cladding Pages Rapid Spacers F-2 to F-3 Drip Rail F-4 Gasketing F-5 to F-7 Cladding Systems F-8 to F-11 Cladding Gasketing

More information

Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish

Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish ASTM F 1667-05 Table 15 Type 1, Style 10 - Common Nails Size Length

More information

IOM 004 Effective 3/29/04 Rev A. MULTI-VENT Laminar Flow Panels Installation Operation and Maintenance

IOM 004 Effective 3/29/04 Rev A. MULTI-VENT Laminar Flow Panels Installation Operation and Maintenance IOM 004 Effective 3/29/04 Rev A MULTI-VENT Laminar Flow Panels Installation Operation and Maintenance Contents Batten Arrangements...3 Slip-On Battens...4 Ceiling Opening...5 Installation...5 Hanger Bracket

More information

HVAC Spiral Pipe Component Parts

HVAC Spiral Pipe Component Parts VC piral Pipe Component Parts Yellow label union manufacturer of VC piral Pipe component parts tamped Fittings VC component parts will save you time and money on your next spiral pipe job. In a market

More information

The EDGE Self-Sealing Round Duct System

The EDGE Self-Sealing Round Duct System The EDGE Self-Sealing Round Duct System Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903 Ph: 607.733.9988 www.stampedfittings.com Submittal Sheet The EDGE Features, Benefits & Materials

More information

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position. SECTION 074600 VINYL SIDING PART 1 GENERAL 1.1 SECTION INCLUDES A. Vinyl siding. B. Vinyl soffits. C. Accessories and trim. 1.2 RELATED SECTIONS A. Section 06100 - Framing and Sheathing. B. Section 07260

More information

American Power Design, Inc.

American Power Design, Inc. , Inc. FEATURES 4 Customer Selects Output Voltage 4 Ultra Wide Input Ranges (936Vdc, 2060Vdc) 4 Efficiency 89% (typ.) 4 Independently Isolated Outputs 4 SixSided Shielded Case 4 Remote On/Off Control 4

More information

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit For Flexible Metal Conduit SC: Straight Squeeze Type Connector These squeeze type connectors are used to terminate flexible metal conduit to a 1/2 knockout in a dry location box or enclosure. 1/2" and

More information

Thru Wall Floor Seals For New Installation

Thru Wall Floor Seals For New Installation The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or

More information

Stripmaster Wire Stripper. Specifications Stripping Hole Diameter in Inches (mm) Wire Size AWG

Stripmaster Wire Stripper. Specifications Stripping Hole Diameter in Inches (mm) Wire Size AWG Stripmaster and Stripmaster Lite Wire Strippers One-step stripping enhances productivity Spring-action motion increases leverage and reduces operator fatigue Precision-ground, knife-type blades provide

More information

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows. SECTION 233100 DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insulation shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation

More information

Fixture Holes Explanation

Fixture Holes Explanation Fixture Holes Explanation Figure 1. General description of a wire rope isolator and its components A wire rope isolator (WRI) has a simple design composed of the following components: wire rope steel cable,

More information

M1.0 MECHNANICAL FLOOR PLAN

M1.0 MECHNANICAL FLOOR PLAN GENERAL NOTES A. CONTRACTORS AND SUB CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY

More information

Mechanical System Specifications & Detail Drawings

Mechanical System Specifications & Detail Drawings Mechanical System & Detail Drawings 1-888-989-1370 www.lundiausa.com RECOM GROUP INC. 449 Borrego Court San Dimas, CA 91773 Phone: (909) 599-1370 Fax: (909) 599-2291 MECHANICAL SYSTEM SPECIFICATIONS All

More information

MANUAL INSTALLATION. Linear Bar Grille LBP. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Linear Bar Grille LBP. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Linear Bar Grille LBP v000 Issue Date: 09/17/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Overview...1 Before You Start...1 Getting Started...1

More information

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT)

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT) ommercial Grade Fittings Set-Screw Fittings I5404 / I5408 I5404IT / I5408IT I5004 (-IT) / I5008 (-IT) I5410 / I5432 I5410IT / I5432IT I5010 (-IT) / I5016 (-IT) Regular Insulated Set-Screw Fittings (Steel)

More information

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools... INS-88.300-0A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE 1. Verify Curb Installation... 2 2. Required Installation Tools... 2 3. Unpacking the KSR... 3 4. Attach KSR Bottom Rail to Curb... 5 5. Attach

More information

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 53 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe markers. 5. Ceiling tacks. 6. Labels. 7. Lockout

More information

DUO-TAPTITE. Fasteners DUO-TAPTITE. Thread Rolling Screws

DUO-TAPTITE. Fasteners DUO-TAPTITE. Thread Rolling Screws Fasteners Percent thread chart... Page 8 Pilot hole sizes... Page 9 Typical torque performance... Page 10 Typical single punch extruded holes... Pages 11 & 12 Die cast cored holes... Page 12 CORFLEX...

More information

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Linear Bar Grille - Heavy Duty LBPH/LBMH v000 Issue Date: 09/17/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Overview...1 Before You Start...2

More information

SECTION AIR DISTRIBUTION SYSTEM

SECTION AIR DISTRIBUTION SYSTEM SECTION 23 30 00 AIR DISTRIBUTION SYSTEM PART 1 - GENERAL 1.1 Scope of Work: The work covered by this section consists of providing all labor, equipment and materials and performing all operations necessary

More information

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features UNILETS for use with Threaded Rigid Conduit and IMC. All Device Boxes have Construction. Furnished with Internal Ground Screw. Applications Accommodate wiring devices such as switches and receptacles.

More information

*************************************************************************************************************

************************************************************************************************************* 15890 DUCTWORK ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 23 33 13 *************************************************************************************************************

More information

Single-Hung Windows Premium Atlantic Aluminum

Single-Hung Windows Premium Atlantic Aluminum TABLE OF CONTENTS Specifications... 2-2 QuickSpecGuide... 2-3 Elevations: Scale Single-Hung-FloridaSizes... 2-4 Grille Patterns... 2-5 SectionDetails: 6 Scale... 2-6 InstallationWallDetails... 2-10 PagethroughthePDFusingthebutonsontheright,

More information

1.) Type: VL-F Single compartment rectangular smoke extraction ducts and fittings

1.) Type: VL-F Single compartment rectangular smoke extraction ducts and fittings 1.) Type: VL-F Single compartment rectangular smoke extraction ducts and fittings 2.) Manufacturer / Place of manufacture: AEROPRODUKT Zrt., 6640 Csongrád, Szegedi út 1., HUNGARY 3.) Function: The smoke

More information

General Information...SA1-SA4

General Information...SA1-SA4 SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................

More information

VAV Rectangular Terminal Units

VAV Rectangular Terminal Units RSVQ VAV Rectangular Terminal Units RSVQ Variable Air Volume (VAV) HVAC systems are the best solution to guarantee high levels of comfort and energy effi ciency in civil and industrial applications VAV

More information

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job: Catalog number: and Finish Options: See page 2 : See pages 3-5ˇ Approvals: Date: Page: 1 of 5 Specifications Lamp Housing: Die-cast brass with die-cast cover, stainless steel fasteners and stainless steel

More information

Small Block Ford. 289 / 302 / 351W / 5.0 Installation Manual For Systems with A/C #13600 / #13620

Small Block Ford. 289 / 302 / 351W / 5.0 Installation Manual For Systems with A/C #13600 / #13620 Small Block Ford 289 / 302 / 351W / 5.0 Installation Manual For Systems with A/C #13600 / #13620 Billet Specialties, Inc. 500 Shawmut Avenue. La Grange, Illinois 60526 Tech Line (708) 588-0505 Fax (708)

More information

SECTION 10. SAFETY METHODS FOR TURNBUCKLES

SECTION 10. SAFETY METHODS FOR TURNBUCKLES SECTION 10. SAFETY METHODS FOR TURNBUCKLES 7-179. GENERAL. Safety all turnbuckles with safety wire using either the double or single-wrap method, or with any appropriately approved special safetying device

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-08 33 13 (May 2009) Change 2-11/12 --------------------------- Preparing Activity: USACE Nontechnical Title Revision (August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

TABLE OF CONTENTS: SHEET 3: REMOTE DRIVER BOX INSTALLATION SHEET 7: OCTAGON JUNCTION BOX INSTALLATION

TABLE OF CONTENTS: SHEET 3: REMOTE DRIVER BOX INSTALLATION SHEET 7: OCTAGON JUNCTION BOX INSTALLATION TABLE OF CONTENTS: SHEET 2: MULLION SYSTEM INSTALLATION SHEET 3: REMOTE DRIVER BOX INSTALLATION SHEET 4: 2 X 4 EXTERIOR TRANSITION PLATE INSTALLATION SHEET 5: 2 X 4 EXTERIOR INSTALLATION SHEET 6: 4 X 4

More information

Ground Clamps Cable Tray

Ground Clamps Cable Tray commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and

More information

Installation Instructions

Installation Instructions Installation Instructions 200 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised April 2014 dependable@tubeliteinc.com Page 1 TABLE OF

More information

TAPTITE Fasteners. High Performance Thread Rolling Screws for Metals

TAPTITE Fasteners. High Performance Thread Rolling Screws for Metals TAPTITE 2000 Fasteners High Performance Thread Rolling Screws for Metals TAPTITE 2000 thread forming technology joins two unique concepts and advances fastener performance to new levels. TAPTITE 2000 fasteners

More information

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS Strength Adjustable From Size 1 Thru 6 CAUTION: FAILURE TO INSTALL OR ADJUST PROPERLY MAY RESULT IN INJURY OR DAMAGE Auxiliary

More information

Small Block Ford. 289 / 302 / 351W / 5.0 Installation Manual For Systems without A/C #13605 / #13625

Small Block Ford. 289 / 302 / 351W / 5.0 Installation Manual For Systems without A/C #13605 / #13625 Small lock Ford 289 / 302 / 351W / 5.0 Installation Manual For Systems without /C #13605 / #13625 illet Specialties, Inc. 500 Shawmut venue. La Grange, Illinois 60526 Tech Line (708) 588-0505 Fax (708)

More information

CAN BE INSTALLED DIGITAL DEPTH GAGE WITH EXTENSION BASE DATA OUTPUT 48-52, MM/INCH

CAN BE INSTALLED DIGITAL DEPTH GAGE WITH EXTENSION BASE DATA OUTPUT 48-52, MM/INCH E16 SPECIAL MEASURING JAWS GAGE *The mm measuring jaw can be customized according to design drawing or measurement item of workpiece Unit: to suit your particular requirements. E17 Digital Caliper (Tungsten

More information

METRIC FASTENERS 1520 METRIC FASTENERS

METRIC FASTENERS 1520 METRIC FASTENERS 1520 METRIC FASTENERS METRIC FASTENERS A number of American National Standards covering metric bolts, screws, nuts, and washers have been established in cooperation with the Department of Defense in such

More information

Engineering Data Rail Lifters

Engineering Data Rail Lifters Engineering Data Rail Lifters Bolt On Ready Stock Rails This product may be covered by one or more patents or patent applications. See http://www.standardlifters.com/patents.html for details. 12/13 - Rev.

More information

77 cm. 5243/3-GA (3 pcs.) 5243/3-BO (3 pcs.)

77 cm. 5243/3-GA (3 pcs.) 5243/3-BO (3 pcs.) ARCHIMEDE ST.102-4ENG SPECIFICATION Range: ARCHIMEDE Design: Caimi Lab 5203-GA, 5203-BO, 5213-GA, 5213-BO, 5223-GA, 5223-BO, 5233/3-GA, 5233/3-BO, 5241/3-GA, 5241/3-BO, 5243/3-GA, 5243/3-BO, 5245/3-GA,

More information

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details. SECTION 081113 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standard hollow metal doors and frames. 1.2 SUBMITTALS A. Product Data: For each type of product indicated.

More information

1. ASME A Scheme for the Identification of Piping Systems.

1. ASME A Scheme for the Identification of Piping Systems. SECTION 40 05 53 - IDENTIFICATION FOR PROCESS PIPING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe markers. 5. Labels. 6. Lockout devices. B. Related Requirements:

More information

DIBD20, 40, 60 AND DIBD230, 430, 630 CURTAIN TYPE DYNAMIC FIRE DAMPERS

DIBD20, 40, 60 AND DIBD230, 430, 630 CURTAIN TYPE DYNAMIC FIRE DAMPERS 00 Dr. Greaves Rd. Kansas City, MO 00 (1) 1- F (1) - DID, 0, 0 ND DID0, 0, 0 CURTIN TYPE DYNMIC FIRE DMPERS 1 1 / ND OUR UL RTED FOR USE IN DYNMIC ND STTIC SYSTEMS PPLICTION DID, 0, 0 fire dampers can

More information

Product Selection Guide

Product Selection Guide Selection Guide GLAZING PRODUCTS DOOR LOUVERS VISION FRAMES D o o r P r o d u c t s 4958 Stout Dr. #119 San Antonio, TX 78219 210.662.6300 Fax 210.662.2828 E-mail door@anemostat www.anemostat V I S I O

More information

!When using electrical equipment, basic safety precautions should always be followed, including the following: INSTALLATION INSTRUCTIONS

!When using electrical equipment, basic safety precautions should always be followed, including the following: INSTALLATION INSTRUCTIONS TABLE OF CONTENTS: SHEET 2: MULLION SYSTEM INSTALLATION SHEET 3: REMOTE DRIVER BOX INSTALLATION SHEET 4: 2 X 4 EXTERIOR WITH TRANSITION PLATE INSTALLATION SHEET 5: 2 X 4 INSTALLATION SHEET 6: 4 X 4 EXTERIOR

More information

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018 SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions 14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6

More information

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM )

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM ) Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM ) No. Trade Dimensions (mm) Size I.D. A B C Threads YCM-03 3/8 11.2 28.3 44.6 13.2 PT 1/2 YCM-04 1/2 14.8

More information

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance.

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance. Corrosion Resistant liquid tight conduit fittings for use with flexible liquid tight metallic conduits, flexible liquid tight non metallic or PVC coated flexible metal conduit. * Liquidtight, Raintight,

More information

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700 SECTION 23 3113 - LOW PRESSURE DUCTWORK PART 1 - GENERAL 1.1 SCOPE OF WORK: A. The work required under this section includes all work necessary for a complete installation of ductwork and accessories.

More information

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS UDC 621.882.211 [669.14.018.291] IS : 3757-1985 (Reaffirmed 2003) Edition 3.2 (1989-07) Indian Standard SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS ( Second Revision ) (Incorporating Amendment Nos.

More information

3 Eco-Downlight IC Air-Tight Adjustable New Construction Housing Round or Square

3 Eco-Downlight IC Air-Tight Adjustable New Construction Housing Round or Square 3 Eco-Downlight Wattage CCT Delivered Lumens Efficacy 13W 13W 21W 21W 21W 2700K 3000K 2700K 3000K 3500K 1000lm 1200lm 1700lm 1850lm 2000lm Lumens will vary depending on optic, finish & trim type 77lpw

More information

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW GENERL PROUCT OVERVIEW Ceiling iffusers Quality ssured Products, unobtrusive clean lines for appearance, careful engineering and professional workmanship with the backing of an industry leader - these

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

Square Shear Beam Mounting Guidelines

Square Shear Beam Mounting Guidelines Issue Date: January 2016 Please Retain for Future Reference 2016-01-11 Square Shear Beam Mounting Guidelines Subject: Square Shear Beam Recommendations Introduction: Even though Digi-Star load cells are

More information

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube MODEL 240I SECTION 08120 FLUSH ALUMINUM DOORS AND FRAMES PART I GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to deliver and install aluminum doors, frames,

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION SECTION 15190 MECHANICAL IDENTIFICATION PART 1 GENERAL 1.01 SECTION INCLUDES A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe Markers. 1.02 SUBMITTALS A. Submit valve chart and schedule,

More information

R SERIES Premium Music R.5-96MAX HIGH OUTPUT FULL-RANGE 90 x 60 WEATHER-RESISTANT LOUDSPEAKER

R SERIES Premium Music R.5-96MAX HIGH OUTPUT FULL-RANGE 90 x 60 WEATHER-RESISTANT LOUDSPEAKER R SERIES Premium Music FEATURES Low distortion, high quality musicality, excellent speech intelligibility in a compact enclosure High sensitivity, high output (130 db max) Weather-resistant, rotomolded

More information

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering Change from one to two columns Data Sheet 10/10-3.61-EN Rev. D SensyTemp TSB (B R) Resistance thermometer for building automation, machine construction and environmental engineering Measurement made easy

More information

Body Repair. Collision Repair. Specification. Fastener Specifications Fastener Specifications. Blind Rivet. Flow Drill Screw (FDS) Torque FDS

Body Repair. Collision Repair. Specification. Fastener Specifications Fastener Specifications. Blind Rivet. Flow Drill Screw (FDS) Torque FDS Body Repair Collision Repair Specifications Fastener Specifications Fastener Specifications Application Specification Metric English Cross-Car Brace Mounting Bolts 25 Y 18 lb ft Windshield Frame Mounting

More information

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

CARRIER OVERHANG 1'-0 MAX PANEL LENGTH 3'-0 MIN - 16'-0 MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise) DETAIL 5 32 5 " 27 32 " 6" OPTIONAL FLAT RECESSED CLOSURE 1 1 4 " 17 32 " 1 25 32 " OPTIONAL BUTTERFLY CLOSURE CARRIER OVERHANG 1'-0" MAX CARRIER SPAN 4'-0" 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER

More information

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Specification Tapped holes f. coupl Scope Allocation of the JED Numbers General...

Specification Tapped holes f. coupl Scope Allocation of the JED Numbers General... WABCO Specification 2003-07 Class: Engineering Guidelines Class No.:62 Tapped Holes for Couplings JED according to ISO 4039-2 464 Previous Edition Abbreviated Title 1985-11 Tapped holes f. coupl. 852 004

More information

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of

More information

1.2 Overview. Self-adhesive mounting bases and clamps for screw and rivet mounting. Typical applications

1.2 Overview. Self-adhesive mounting bases and clamps for screw and rivet mounting. Typical applications 1.2 Overview Self-adhesive mounting bases and clamps for screw and rivet mounting The main difference between a mounting base and a cable clamp is the way the cable bundle can be mounted: while the cable

More information

Pioneers in Gate Design

Pioneers in Gate Design Stop Logs Pioneers in Gate Design Hydro Gate 3888 E. 45th Ave. #120 Denver, CO 80216 Your Source for Water Control Gates No matter what type of gates your project demands, chances are excellent Hydro Gate

More information

05/11. CI/SfB (22) flexplus. tenon. Versatility through simplicity.

05/11. CI/SfB (22) flexplus. tenon. Versatility through simplicity. CI/SfB 05/11 (22) flexplus tenon Versatility through simplicity flexplus tenon flexplus at a glance GENERAL OFFICE CLEAN ROOMS LIGHT INDUSTRIAL DURABLE SURFACES Areas of use 4 4 4 4 Fire performance Solid

More information

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

11-SDMS-03 REV. 02 SPECIFICATIONS FOR 11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information