LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

Size: px
Start display at page:

Download "LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION"

Transcription

1 CAUTION: BEFORE BEGINNING INSTALLATION REVIEW LAYOUT DRAWINGS, AND SHIPMENT. MAKE SURE ALL LIGHT S AND MATERIALS ARE ON SITE AND READILY ACCESSIBLE. IF ANY ICON MATERIALS ARE MISSING, CONTACT ICON INTERNATIONAL BEFORE BEGINNING INSTALLATION. LIGHT S MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION For ease of installation and maintenance, the Eclipse Wall Wash Lighting System is shipped in two parts: light fixture housings and drop-in light fixture strips. All light fixture housings should be installed first. Once all light fixture housings are installed, light strips can be dropped into required location. Each fixture installation is custom designed and engineered by ICON s engineering department. With every order, a lighting fixture layout is provided by ICON. SEE LAYOUT DRAWING EXAMPLE for typical layout designations. Every layout provided by ICON includes detailed information as to how the system should be installed. Every housing and drop in light strip is labeled to match the lighting system layout provided by ICON. Prior to beginning installation of the lighting system, review the lighting fixture layout provided by ICON. Fixture rows should be built from left to right using the fixtures designated on the provided lighting fixture layout drawings To ease installation, before beginning lighting fixture installation, locate required fixture numbers, as indicated on layout drawing, and move to location to be installed. Line up fixture cartons on floor under the ceiling location they are to be installed. 11 NUMBER 19 WALL SIDE 15 LEFT END INSTALL FIRST MID INSTALL SECOND TRIMMABLE INSTALL LAST DROP IN LIGHT S31A S31B S41A T41B STRIP NUMBER INSTALL LEFT END CAP WALL SIDE (INSTALL S FROM LEFT TO RIGHT) INSTALL RIGHT END CAP WALL SIDE LAYOUT DRAWING EXAMPLE REV DESCRIPTION DATE BY Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 1 of 15

2 STEP 1 INSTALL JTRIM A. On left side of fixture row, install first piece of J-trim. Each fixture is supplied with a corresponding length of J- trim which is included in the fixture carton. Before beginning J-trim installation, remove all J-trim from cartons and position in appropriate locations. J-trim must be installed 2-13/16" above ceiling line. J-trim must be installed 1 ½" in from end of fixture row to allow for end cap. Install J-trim to wall using self drilling screws (by others). All screws must be installed into structure suitable for supporting fixture weight (such as wall stud). J-TRIM MUST BE INSTALLED LEVEL B. Install remaining fixture J-trim pieces, except for last fixture. All J-trim should be installed to butt against and level with the previous installed J-trim. C. The last piece J-trim will need to be field trimmed to proper length. After all other J-trim has been installed, measure remaining opening. Subtract 1 ½" from this measurement to determine the proper cut length. D. Using an appropriate tool cut the last piece of J-trim to the proper cut length determined in Step C. Install the cut J- trim piece in the same manner as previous J-trim pieces. When all J-trim pieces have been installed, they should look like the figure INSTALLED J-TRIM - EXAMPLE shown below. SELF DRILLING SCREWS LAST PIECE OF FIELD TRIM TO REMAINING OPENING MINUS 1 1/2" TO ACCOMODATE END CAP DRILL POINT SCREW REFLECTOR DROP IN LIGHT STRIP CEILING TRIM CEILING WIRE TIE SHIPPING BRACKET MAINTAINS OPENING (DO NOT REMOVE UNTIL ENTIRE ROW HAS BEEN INSTALLED AND CEILING HAS BEEN BUILT AROUND S) INSTALLED PROFILE (FOR REFERENCE) 1 1/2" 38.1mm OFF WALL TO CLEAR END CAPS INSTALLED JTRIM EXAMPLE 1 1/2" 38.1mm OFF WALL TO CLEAR END CAPS DRILL POINT SCREW TO BE SECURED TO STRUCTURE OF SUITABLE STRENGTH TO SUPPORT WEIGHT OF LIGHT S WALL SIDE SELF DRILLING SCREW 1 1/2" 38.1mm FROM WALL EDGE CEILING (INSTALED AFTER COMPLETE LIGHT INSTALLATION) DRILL POINT SCREW STRUCTURAL SUPPORT 2 13/16" 70.82mm JTRIM INSTALLATION JTRIM HORIZONTAL POSITIONING TOP VIEW JTRIM VERTICAL POSITIONING Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 2 of 15

3 STEP 2 INSTALL LIGHT SUPPORT WIRES A. Each fixture to be installed is supported by the previously installed J-trim (by Icon) and by wire ties (by others). The wire ties must be attached to the structural ceiling. Each fixture requires the following number of wire ties: 8 fixtures 3 wire ties per fixture 6 Fixtures 3 wire ties per fixture 4 Fixture 2 wire ties per fixture 3 Fixture 2 wire ties per fixture 2 Fixture 2 wire ties per fixture (See WIRE TIE LOCATIONS EXAMPLE for details.) B. All wire ties should be installed a maximum of 8 ½ from the wall on which the J-trim was installed. Wire ties should be of adequate length to allow installation of fixture. (See WIRE TIE POSITION diagram for details) C. Install wire ties above first fixture. The first wire tie should be installed 1" from left wall. (See WIRE TIE LOCATIONS - EXAMPLE for details) D. Install remaining wire ties as dictated by fixture layout. Only one (1) wire tie is required at all light fixture joints. (See WIRE TIE LOCATIONS - EXAMPLE for details) E. Wire ties will be installed at the end of each fixture. For 8 and 6 fixtures, the middle wire tie will be installed at the center of the fixture. (See WIRE TIE LOCATIONS - EXAMPLE for details) WALL SIDE 8 1/2" 215.9mm MAX WIRE TIE POSITION WIRE TIE 1" 25.54mm STRUCTURAL CEILING 1" 27.57mm WIRE TIE WIRE TIE WIRE TIE WIRE TIE WIRE TIE WIRE TIE ' mm JOINT ' mm JOINT ' mm JOINT TRIMMABLE mm WIRE TIE LOCATIONS EXAMPLE Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 3 of 15

4 STEP 3 INSTALL END CAP ON FIRST LIGHT HOUSING (LEFT END) A. Unpack first light fixture housing (left end) to be installed. B. Locate ICON supplied End Cap Kit (P/N ). Remove Left End Cap and four (4) #8B x ¼ sheet metal screws. Set aside remaining end cap and screws for installation on opposite side of fixture row. REFLECTOR CEILING WIRE TIE C. Install Left End Cap. Align End Cap with fixture profile and secure to fixture using four (4) #8B x ¼ sheet metal screws. Note: aligning tab on end cap should slide into aligning slot on back of extruded inner trim.(see STEP 3C DETAIL) DRILL POINT SCREW SHIPPING BRACKET MAINTAINS OPENING (DO NOT REMOVE UNTIL ENTIRE ROW HAS BEEN INSTALLED AND CEILING HAS BEEN BUILT AROUND S) DROP IN LIGHT STRIP CEILING TRIM NOTE: S ARE SHIPPED WITH SHIPPING SPACER BRACKETS INSTALLED. THESE BRACKETS ARE USED TO MAINTAIN A CONSISTENT LIGHT OPENING DURING SHIPPING AND INSTALLATION. THESE SPACERS MUST REMAIN INSTALLED UNTIL CEILING HAS BEEN CONSTRUCTED AROUND COMPLETED LIGHT INSTALLATION. INSTALLED PROFILE (FOR REFERENCE) END CAP 1 LEFT #8B X 0.25" SHEET METAL SCREW SHIPPING BRACKET KEEP INSTALLED IN LIGHT S TO MAINTAIN CONSISTENT OPENING UNTIL CEILING IS BUILT ALIGNING SLOT ALIGNING TAB STEP 3C DETAIL Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 4 of 15

5 STEP 4 INSTALL FIRST LIGHT HOUSING (LEFT END) A. Lift first fixture (left end) into place and hook outer extrusion into J-trim. Push fixture in towards back wall as far as possible to minimize visibility of J-trim. (See STEP 4A DETAIL) B. Use previously installed wire ties to secure other side of fixture. Thread wire ties through holes in fixture gusset and adjust wire ties such that fixture is secure and level. (See STEP 4B DETAIL) C. Slide fixture to the left until the end cap flange butts against wall, or the fixture is in desired position. When fixture is installed it should look like figure in STEP 4C DETAIL THREAD WIRE TIE THROUGH HOLES IN HOUSING WIRE TIE STRUCTURAL CEILING GUSSET OUTER EXTRUSION STEP 4A DETAIL SHIPPING SPACER BRACKET DO NOT REMOVE UNTIL ALL S AND CEILING HAVE BEEN INSTALLED SLIDE IN THIS DIRECTION AS FAR AS POSSIBLE TO MINIMZE VISIBILITY STEP 4B DETAIL WIRE TIE THREAD THROUGH HOLES IN BRACKET WIRE TIE THREAD THROUGH HOLES IN BRACKET SLIDE IN THIS DIRECTION UNTIL END CAP FLANGE BUTTS AGAINST WALL INSTALL SO IT IS LEVEL AND RESTS SECURELY IN WIRE TIES STEP 4C DETAIL Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 5 of 15

6 STEP 5 INSTALL NEXT LIGHT HOUSING (MID) 1/4120 BOLT A. Lift next fixture housing into place and hook outer extrusion into J-trim. Push fixture housing in towards back wall as far as possible to minimize visibility of J-trim. (See STEP 4A DETAIL) B. Use previously installed wire ties to secure other side of fixture. Thread wire ties through holes in fixture housing and adjust wire ties such that fixture is secure and level. (See STEP 4B DETAIL) C. Locate ICON supplied Joining Kit (P/N ). Install three (3) Extrusion Aligners from joining kit into Inner and Outer Extrusion of adjacent fixture. Extrusion Aligners should be slid into slots located on Inner and Outer extrusion for approximately ½ their length. (See STEP 5C DETAIL) D. Bring fixtures together, making sure Extrusion Aligners are seated in the corresponding inner and outer extrusion slots of the fixture to be joined. Join the two fixtures using three (3) ¼ -20 x 1 bolts and three ¼ - 20 wing nuts supplied in Joining Kit. (See STEP 5D DETAIL) E. When joining is complete fixture joint should look like STEP 5E DETAIL. OUTER EXTRUSION ALIGNER SLOTS PREVIOUSLY INSTALLED EXTRUSION ALIGNER 1/4120 WING NUT BEING INSTALLED OUTER EXTRUSION STEP 5D DETAIL 1/4120 WING NUT EXTRUSION ALIGNERS ALIGNER SLOT STEP 5C DETAIL STEP 5E DETAIL Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 6 of 15

7 STEP 6 INSTALL REMAINING MID HOUSINGS A. Install remaining mid fixture housings as shown in Step 5. B. Follow Steps 7-10 to install last fixture housing (end right) REFLECTOR CEILING WIRE TIE DRILL POINT SCREW DROP IN LIGHT STRIP STEP 7 TRIM LAST (END RIGHT) TO PROPER SIZE A. After End Left Fixture and all Mid Fixtures have been installed, measure remaining opening for last fixture (End Right Fixture). Subtract 1 from this measurement to determine proper cut length for End Right Fixture. (See STEP 7A DETAIL) SHIPPING BRACKET MAINTAINS OPENING (DO NOT REMOVE UNTIL ENTIRE ROW HAS BEEN INSTALLED AND CEILING HAS BEEN BUILT AROUND S) CEILING TRIM INSTALLED PROFILE (FOR REFERENCE) MEASURE OPENING AND SUBTRACT 1" TO mm DETERMINE CUT LENGTH INSTALLED END LEFT INSTALLED MID S WIRE TIES STEP 7A DETAIL Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 7 of 15

8 STEP 7 TRIM LAST HOUSING (END RIGHT) TO PROPER SIZE CONT'D B. Remove Shipping Brackets out of C. Remove the screws securing the fixture housing. Set Shipping Gussets to the fixture housing. The Brackets aside, they will be reinstalled after fixture is trimmed. BE Philips head screws and one (1) Gussets are secured with five (5) #8B SURE NOT TO DAMAGE Philips head self drilling screw. HOUSING FINISH Remove all Gussets from the fixture WHEN REMOVING SHIPPING housing. Place screws aside for BRACKETS. (See STEP 7B future use. (See STEP 7C DETAIL) DETAIL) D. Remove the screws securing the Inside Extrusion to the Outside Extrusion. Slide the two extrusions apart. Place screws aside for future use. (See STEP 7D DETAIL) HEAD SCREWS HEAD SCREWS OUTER EXTRUSION SHIPPING BRACKET STEP 7B DETAIL HEAD SCREW GUSSET PHILIPS SELF DRILLING SCREW STEP 7C DETAIL (TYP BOTH ENDS) HEAD SCREW Description: PRIME 44 WW 2120 SNAP IN STRIP STEP 7C DETAIL (TYP ALL GUSSETS) Sheet 8 of 15

9 STEP 7 TRIM LAST HOUSING (END RIGHT) TO PROPER SIZE CONT'D E. Measure from left end of Inner and Outer Extrusions to the cut length determined in Step 7A and mark Inner and Outer Extrusion. F. Remove Inner and Outer Extrusions. Using an appropriate tool, cut the Inner and Outer Extrusions on the mark from step 7E. File down any sharp edges that result from cutting. Be sure to use a saw blade designed to cut aluminum when cutting the extrusions mm MEASURE AND CUT LENGTH DETERMINED IN STEP 7A mm MEASURE AND CUT LENGTH DETERMINED IN STEP 7A STEP 7F STEP 7F Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 9 of 15

10 STEP 8 REASSEMBLE TRIMMED HOUSING A. Slide trimmed outer extrusion into slot on inner extrusion and secure with #8B x.25 screws removed in Step 7. (See STEP 8A DETAIL) B. Use #8B x.25 sheet metal screws removed in Step 7 to secure the fixture Gussets to the inner and outer extrusions. The end gussets should be set in from the end of the housing approximately 1/32 of an inch. (See STEP 8B DETAIL) STEP 9 INSTALL RIGHT END CAP A. Locate Right End Cap and (4) #8b x ¼ screws which were set aside in Step 3 from ICON supplied End Cap Kit (p/n ). B. Install Right End Cap. Align End Cap with fixture profile and secure to fixture using four (4) #8b x ¼ sheet metal screws. Note: aligning tab on end cap should slide into aligning slot on back of extruded inner trim. (See STEP 9B DETAIL) HEAD SCREW HEAD SCREWS GUSSET PHILIPS SELF DRILLING SCREW HEAD SCREW HEAD SCREWS OUTER EXTRUSION STEP 7C DETAIL (TYP ALL GUSSETS) #8B X 0.25" SHEET METAL SCREWS ALIGNING SLOT INNER EXTRUSION STEP 8A DETAIL (TYP BOTH ENDS) STEP 9B DETAIL ALIGNING TAB END CAP 1 RIGHT Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 10 of 15

11 STEP 10 INSTALL END RIGHT HOUSING A. Locate ICON supplied Joining Kit (P/N ). Install three (3) Extrusion Aligners from joining kit into Inner and Outer Extrusion of adjacent fixture. FOR THE LAST Extrusion Aligners should be slid COMPLETELY into slots located on Inner and Outer extrusion of adjacent installed fixture. (See STEP 5C DETAIL) ADJACENT END RIGHT ADJACENT END RIGHT B. Lift End Right fixture into place and hook outer extrusion into J-trim. Push fixture in towards back wall as far as possible to minimize visibility of J-trim. (See STEP 4A DETAIL) C. Use previously installed wire ties to secure other side of fixture. Thread wire ties through holes in fixture gussets and adjust wire ties such that fixture is secure and level. (See STEP 4B DETAIL) D. Align Inner Extrusions of both fixtures and slide the Inner Extrusion Aligner so that it is centered on the joint between fixtures. (See STEP 10E DETAIL) ALIGNER (SLIDE COMPLETELY INTO SLOTS OF OF ADJACENT ) STEP 10E DETAIL ALIGNER CENTERED ON JOINT E. Align Outer Extrusions of both fixtures and slide the two (2) Outer Extrusion Aligners so that they are centered on the joint between fixtures. (See STEP 10F DETAIL) END RIGHT END RIGHT F. Join the two fixtures using three (3) ¼ -20 x 1 bolts and three ¼ - 20 wing nuts supplied in Joining Kit. (See STEP 5E DETAIL) ADJACENT ADJACENT G. When joining is complete fixture joint should look like STEP 5E DETAIL. OUTER EXTRUSION ALIGNERS (SLIDE COMPLETELY INTO SLOTS OF OUTER EXTRUSION OF ADJACENT ) OUTER EXTRUSION ALIGNERS CENTERED ON JOINT STEP 10F DETAIL Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 11 of 15

12 STEP 11 INSTALL SNAP IN LGIHT STRIPS NOTE: SHIPPING SPACER BRACKET MAY NEED TO BE REMOVED TO INSTALL SNAP-IN STRIP. SPACER MUST BE REPLACED AFTER STRIP INSTALLATION. SPACER BRACKETS ARE CRITICAL TO MAINTAIN OPENING WHILE CEILING IS BUILT. A. Install drop in light strips according to layout drawing provided by ICON. against the end cap of the housing (See STEP 11B DETAIL) B. Install end cover in first light strip. Use ICON Strip End Cover Kit # for staggered strips and ICON Strip End Cover Kit # for non-staggered strips. End cover should be installed on end of strip which will be C. Remove finger hole plugs in reflector. Use fingers in holes to hold and insert snap in strip into housing. (See STEP 11B DETAIL) 1 LT STAG STRIP END COVER INSTALLATION 2 LT STAG STRIP END COVER INSTALLATION 1/2 LT NONSTAG STRIP END COVER INSTALLATION FINGER HOLE PLUG FINGER HOLE PLUG #8B X 0.25" SCREW #8B X 0.25" SCREW KNOCK OUT AS REQUIRED STAG STRIP END COVER KNOCK OUT AS REQUIRED NON1STAG STRIP END COVER STEP 11 C DETAIL STEP 11B DETAIL Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 12 of 15

13 STEP 11 INSTALL SNAP IN LGIHT STRIPS CONT'D D. Carefully lift and rotate first strip into housing until it is parallel with back of fixture. Strip should drop into place on rear mounting detail. (See STEP 11D DETAIL) BE VERY CAREFUL NOT TO DAMAGE REFLECTOR FINISH WHEN INSTALLING LIGHT STRIP. E. Slide snap in strip into required position (SEE STEP 11 D DETAIL). F. Replace finger hole plugs which were removed. G. Install second snap in strip. For 1 light staggered lamping, pay careful attention to the orientation of the strip. H. Connect Wire Harnesses between the two snap in strips. (See STEP 11H DETAIL) Make sure the Wire Harnesses are properly orientated before connecting. (See WIRE HARNESS DETAIL) I. Slide second strip into position. Make sure all wires are tucked into the strips before pushing together. Continue installing strips until all strips are installed. J. Install end cover on last strip before it is installed. If the last strip is a telescopic strip, the end cover must be installed in the light strip installed before the telescopic strip. End cover should be installed on end of strip facing the telescopic strip. K. The last strip to be installed should be the telescopic strip. After telescopic strip is installed, the slide should be extended as far as possible. (See STEP 11K DETAIL) STEP 11D DETAIL REMOVE SHIPPING SPACER BRACKET IF NECESSARY STEP 11D DETAIL RE1INSTALL SHIPPING SPACER BRACKET IF REMOVED INSTALL END COVER ON THIS STRIP TELE SLIDE STEP 11 I DETAIL FEMALE HARNESS END LOCKING TAB WHITE (COMMON) BLACK (HOT) LOCKING TAB GREEN (GROUND) WIRE HARNESS PIN ORIENTATION AND DESIGNATION CATCH CATCH WHITE (COMMON) BLACK (HOT) NOTE: SHIPPING SPACER BRACKET MAY NEED TO BE REMOVED TO INSTALL DROP IN STRIP. SPACER MUST BE REPLACED AFTER STRIP INSTALLATION. SPACER BRACKETS ARE CRITICAL TO MAINTAIN OPENING WHILE CEILING IS BUILT. MALE HARNESS END MALE HARNESS PLUG STEP 11H DETAIL WIRE HARNESS PLUG ORIENTATION WIRE HARNESS DETAIL FEMALE HARNESS PLUG Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 13 of 15

14 CAUTION! BE SURE BUILDING POWER CIRCUIT IS SHUT OFF, LOCKED OUT AND SUITABLY TAGGED BEFORE PERFORMING ANY ELECTRICAL WORK. NOTE: ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED ELECTRICIAN AND MUST FOLLOW LOCAL ELECTRICAL CODES. STEP 12 CONNECT BUILDING POWER A. Building power can be connected anywhere along length of fixture run. B. To connect power, drill a hole as required for appropriate wiring adapter in back of fixture housing, typical 7/8 for most adapters. (See STEP 12B DETAIL) C. Install appropriate adapter for building wire to pass through fixture. (Flexible conduit adapter, by others, shown). (See STEP 12C DETAIL) D. Cut wire harness at connection point, strip ends of harness wires and connect to building supply wire using wire nuts or other connectors according to code. (See STEP 12D DETAIL) WIRE NUT OR EQUIVALENT CUT WIRE HARNESS ENDS BUILDING SUPPLY WIRES STEP 12D DETAIL REMOVE KO QUICK WIRE ACCESS PLATE DRILL HOLE AS REQUIRED BY WIRE CONNECTOR TO BE USED (TYP. 7/8") WIRING ADAPTER AS REQUIRED BY LOCAL ELECTRICAL CODES COMPLETED WIRING CONNECTION STEP 12B DETAIL STEP 12C DETAIL Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 14 of 15

15 STEP 13 INSTALL SHIELDING IF REQUIRED A. The Eclipse Wall Wash lighting system can be supplied with optional shielding, either a white acrylic lens or a straight blade baffle. B. To install lens, slide longer leg of lens into opening on ceiling side of fixture. Lift lens into fixture and drop short leg into hook on wall side of fixture. Install lenses from left to right. Trim last lens to fit. Be sure to use a saw blade designed to cut plastic when trimming lens. C. To install baffle, slide straight bent leg of baffle into opening on ceiling side of fixture. Lift baffle into fixture and drop short leg into hook on wall side of fixture. Install baffle from left to right. Trim last baffle to fit. Be sure to use a saw blade designed to cut aluminum when trimming baffle. LENS INSTALLATION BAFFLE INSTALLATION Description: PRIME 44 WW 2120 SNAP IN STRIP Sheet 15 of 15

SERIES S76PF INSTALLATION INSTRUCTIONS

SERIES S76PF INSTALLATION INSTRUCTIONS SERIES S76PF INSTALLATION INSTRUCTIONS STEP 1: Position alignment clip(s). STEP 2: Mount end closures/plates to first steel fixture. STEP 3: Working from left to right, mount each fixture to the run. Attach

More information

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE T F W 604.549.979 604.549.9555 fluxwerx.com INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE fixture housing endcap kit optic kit join kit notch 2 cross section notch 4 cross section 4 4" 4-11/2" 4 /8 (111)

More information

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver. - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install drywall trim versions of TruGroove recessed

More information

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install trimless drywall versions of TruGroove

More information

Assembly Instructions

Assembly Instructions InTandem Table System November 20 InTandem Table System - Worksurface #4 x/" 4 wood screw power beam Tools Provided T-0 Extended Torx Driver T-25 Torx Driver Additional Tools Required Soft protective

More information

INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8

INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8 INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8 90v INNER CORNER KIT "R" (REGRESSED) POSITION CROSS-SECTION VIEW "S" (SHIELDING AT TOP) POSITION CROSS-SECTION

More information

SAE of 7 "R" (REGRESSED) POSITION "S" (SHIELDING AT TOP) POSITION. Tools Required

SAE of 7 R (REGRESSED) POSITION S (SHIELDING AT TOP) POSITION. Tools Required SAE 0 5/6'' Exposed TBar Ceiling FINISHED EDGE WITH JANGLE 90 IC CORNER KIT 5 7/6" 38mm 9/6'' Screw Slot TBar Ceiling "R" (REGRESSED) POSITION 6" CEILING OPENING "S" (SHIELDING AT TOP) POSITION SUPPORT

More information

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations. Installation Instructions for 90EMULTI Multiples EM_. GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations. This product can be dimmed with a standard electronic dimmer or a 0-0V

More information

SETUP INSTRUCTIONS If you would like to tell us about your experience with your setup instructions please us at

SETUP INSTRUCTIONS If you would like to tell us about your experience with your setup instructions please  us at 207 VK-964 General Layout 0 0 Plan View www.classicexhibits.com SETUP INSTRUCTIONS If you would like to tell us about your experience with your setup instructions please email us at info@classicexhibits.com

More information

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions

Insolroll Clutch Operated Shades Installation Instructions Installation Instructions All clutch operated shades are shipped fully assembled and ready for installation. Mounting screws are not provided. Screws for chain guide installation to meet the child safety standards are provided.

More information

Installation Instructions

Installation Instructions Installation Instructions Optima LED 8 Double-Sided StretchLite Perimeter Lit Graphic Display Line Voltage Connector Optima LED DS5 (Double-sided StretchLite Graphic Display) with Graphics Corner Bracket

More information

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT EXPLODED VIEW AND PART CALL OUT CUTOUT DIMENSIONS ON PAGE 2 CEILING BRACING (BY OTHERS) SHEET ROCK METALUX DF SERIES FRAME KIT S282 (2'X2') FIXTURE SHOWN FIXTURE SIZE FRAME KIT PART # 2' X 2' DF-22W-U

More information

5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER

5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER 1/2 K.O. (3/8 K.O. on 165 with factory supplied 3/8 flex conduit fitting) TR - Trim Flange Side Blocking Install Method Secure fixture to structure following instructions below: 1. Remove lens and internal

More information

ADAPT. ABILITY. X 6.50" Example of a continuous row. Shown: hanging the fixture via threaded rods.

ADAPT. ABILITY. X 6.50 Example of a continuous row. Shown: hanging the fixture via threaded rods. AMELUX Suspension Points 6.50" GUV4-HE-FLANGE; GUV6-HE-FLANGE Gyp Board Ceiling INSTALLATION INSTUCTIONS SHEET #: 689-0498 SHEET 1 of 9 (SHEETS 1-4) T5/T5HO (SHEET 5) T5/T5HO LUXOTTICA (SHEETS 6-9) LED

More information

DRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND

DRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND SUPPLEMENTAL INSTALLATION TYPE LG-WWD-44, R-WWD-44 & RP-WWD-44 510553-2000 WHICH IS CONTRARY TO THE CONTAINED HEREIN. P/C PG. 1 OF 1 1/4-20 THREADED ROD OR EQUAL SUPPLIED PANHEAD SHEET METAL SCREW HEX

More information

TH Place, Maspeth, NY Instruction Manual for UNO Exit Signs

TH Place, Maspeth, NY Instruction Manual for UNO Exit Signs 57-10 49 TH Place, Maspeth, NY 11378 Instruction Manual for UNO Exit Signs 1. What is included in this box? Back box with electronics, battery (where applicable), & mounting hardware. Inner trim, LED illuminator

More information

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424 Linesse Linear Luminaire 3 Recessed LINESSE LINEAR LUMINAIRE 3 RECESSED Page 2: Warnings Page 3: Mounting Types and Dimensions Page 4: T-Grid and Joining Fixtures Page 5: Hard Ceiling and Joining Fixtures

More information

Installation Instructions

Installation Instructions For Medium (15-18.5K) + Heavy duty (22-28.5K) Air Conditioner READ BEFORE INSTALLING UNIT To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp

More information

User Instructions Multiline Otter Scoreboard Caddy Assembly

User Instructions Multiline Otter Scoreboard Caddy Assembly List of parts: User Instructions Multiline Otter Scoreboard Caddy Assembly Single Caddy Double Caddy 1 1 Base assembly with attached wheels 2 4 1 1 2 4 4 8 10 20 12 Uprights (60 or 74 aluminum extrusion)

More information

LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420

LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420 Linesse Linear Luminaire 3 Ceiling Mount LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT Page 2: Warnings Page 3: Mounting Configurations Page 4: Power Feed Page 5: Surface Mounting Page 6: Threaded Rod Mounting

More information

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims Installation Instructions for 90ELED-WIC Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims LED E_L_-L_WI. LED - ROUND/ SQUARE FLANGELESS GENERAL PRODUCT I NFORMATION: This product

More information

General Installation Instructions

General Installation Instructions General Installation Instructions WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts and other hazards: Service of the equipment must

More information

a.k.a. casegoods instructions

a.k.a. casegoods instructions a.k.a. casegoods instructions a a.k.a. workwall installation IMPORTANT NOTES Failure to install product according to installation instruction will result in loss of warranty. Tools required for assembly

More information

compile system INSTALLATION GUIDE Updated January 2019

compile system INSTALLATION GUIDE Updated January 2019 INSTALLATION GUIDE Updated January 09 compile system Table of Contents Panels 0 Quick Connect Clips 0 Lock Clips 0 Panel Trims 0 Privacy Glass 0 Post Base Covers 04 Electrical 04 Power Distribution Harness

More information

HP-2 / HP-4 Wall Wash Recessed T-Bar Installation Instructions Overview

HP-2 / HP-4 Wall Wash Recessed T-Bar Installation Instructions Overview HP-2 / HP-4 Wash Recessed T-Bar Installation Instructions Overview NOTES All power connections should be installed according to local/national codes by a Certified Electrician. This installation requires

More information

EOS LED Surface Mounted Luminaire

EOS LED Surface Mounted Luminaire Installation Instruction Sheet INSTALLATION INSTRUCTIONS FOR JOINING AND SUSPENDING FIXTURES WARNING WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions,

More information

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7 I NSTALLAT ION INSTRUC TIONS 6 3 /4 6 3 /4 3¾ 5 1 /2 For LP installs, ceiling opening is equal to row length + 3 /4 8 1 /2 4 3 /32 5 1 /4 Flush X7 Shown PARTS SHIPPED SEPARATELY 4 3 /32 5 1 /4 3" Regressed

More information

NX7 SERIES 5-1/2 HANDRAIL

NX7 SERIES 5-1/2 HANDRAIL STORAGE & HANDLING The handrails are shipped unassembled. Upon receipt, immediately check all material for any damage that may have occurred in transit and verify that all of the items and quantities are

More information

Interra Installation Manual

Interra Installation Manual Interra Installation Manual Instructions to install the Friant Interra panel system Friant & Associates, LLC Table of Contents Getting Started Introduction... 3 General Tools, Staging & Safety... 4 Before

More information

Angled Side Flush with Panel Face

Angled Side Flush with Panel Face Identify and sort panels by like sizes, fabrics, surface type (tackable vs hard), and NON- POWERED vs POW- ERED. Non-powered panels ship without a powerway. Powered panels include a powerway. See below.

More information

Height Adjustable Benching End Panel and Utility Pole

Height Adjustable Benching End Panel and Utility Pole Height Adjustable Benching End Panel and Utility Pole Tools required: END PANEL Jig Saw Power Drill END PANEL WITH UTILITY POLE Bit Holder Long #2 Square Drive Bit 5mm Hex Drive Bit UTILITY POLE Level

More information

INDIVIDUAL MOUNTING: T-Bar

INDIVIDUAL MOUNTING: T-Bar X1 (T-BAR) INSTALLATION INSTRUCTIONS GENERAL NOTES NOTE : Additional support to structural member may be required. Check with local building codes for requirement. 1. Place troffer clamp approx. 6 from

More information

STEP 1 : DESTROYER FRONT BUMPER INSTALL GATHER YOUR TOOLS AND LAY OUT YOUR PARTS... *shorty bumper to show hardware* Tools Required:

STEP 1 : DESTROYER FRONT BUMPER INSTALL GATHER YOUR TOOLS AND LAY OUT YOUR PARTS... *shorty bumper to show hardware* Tools Required: DESTROYER FRONT BUMPER INSTALL JL STEP 1 : GATHER YOUR TOOLS AND LAY OUT YOUR PARTS... Tools Required: - Utility knife - 11/16 Deep socket - Ratchet - 11/16 Crescent wrench - Ratchet Extension - 1/4 socket

More information

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents LCD LIFT Flat Panel Display System Installation Manual Table of Contents Page Installation Overview... 2 Trim Ring Installation... 3 LCD Lift Installation....4 Actuator Switch Installation.5 Top Plate

More information

FACTORY STRETCH INSTALLATION INSTRUCTIONS

FACTORY STRETCH INSTALLATION INSTRUCTIONS !! Important!! Make sure all power is disconnected prior to installation. Wiring to be done according to Local and National Electric Codes by a qualified electrician. Make sure the building and/or structure

More information

6 Foot/ 1800mm Aisle Width Net-Contain Aisle Containment for N-Type and S-Type Cabinets

6 Foot/ 1800mm Aisle Width Net-Contain Aisle Containment for N-Type and S-Type Cabinets 6 Foot/ 1800mm Aisle Width Net-Contain Aisle Containment for N-Type and S-Type Cabinets Panduit Corp. 2016 INSTALLATION INSTRUCTIONS Page 1 of 36 Component Guide for Doors Dual Sliding Containment Door

More information

Installation Instructions

Installation Instructions edium + Heavy duty READ BEFORE INSTALLING UNIT Preliminary instructions: 1. Check window opening size: the mounting parts furnished with this air conditioner are made to install in a wooden sill double-hung

More information

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION edium + Heavy duty READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Pay attention to danger and safety notices. be exposed: Carefully

More information

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS MantelMount TMA Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS TM Thank you for choosing the MantelMount television wall mount. Please read this entire manual before

More information

R Form No MILLENNIUM GONDOLA / WALLCASE ASSEMBLY

R Form No MILLENNIUM GONDOLA / WALLCASE ASSEMBLY R06-19-06 - Form No.08335-0109 POST THIS WARNING PAGE IN A CONSPICUOUS PLACE, CLEARLY VISIBLE TO ALL STORE PERSONNEL READ BEFORE ASSEMBLING WARNING FOR YOUR SAFETY Install all shelving units according

More information

TrendWall Floor-To-Ceiling Panels Installation Instruction

TrendWall Floor-To-Ceiling Panels Installation Instruction TrendWall Floor-To-Ceiling Panels Installation Instruction TrendWall Components Covered by this Instruction: Crown (and accessories) Floor Plate Solid Panel Filler Panel Wall Channel Door Section Pilaster

More information

Figure A. Figure B. Figure C. Figure D

Figure A. Figure B. Figure C. Figure D Xsite 1 Power/Data Tile and Components Tools Required Tape Measure Cordless Drill/Driver #2 Phillips Screw driver bit Rubber Mallet Flat Blade Screwdriver Figure A Hardware Required Provided as shown Installation

More information

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange - Trim System Overview These instructions review how to install TruGroove Perimeter fixtures. Modules can be installed as individual standalone units, or they can be joined together to create continuous

More information

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 "HERITAGE" F-150/250LD 2WD, 97-04, 04 "HERITAGE" 4WD WD EXPEDITION/ WD EXPEDITION PART

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 HERITAGE F-150/250LD 2WD, 97-04, 04 HERITAGE 4WD WD EXPEDITION/ WD EXPEDITION PART INSTALLATION INSTRUCTIONS 3 BULL BAR PART #B-F1971;B-F2971 PARTS LIST: 1 Bull Bar 2 12-1.75mm x 130mm x 40mm Hex Bolts 1 Driver/Left Mounting Bracket 4 12-1.75mm x 35mm Hex Bolts 1 Passenger/Right Mounting

More information

Dubnium 11 Installation Instructions & Parts List

Dubnium 11 Installation Instructions & Parts List Dubnium 11 Installation Instructions & Parts List Illustration Dubnium, H1 Handle Right Hand: Open Out Page 1 of 25 IMPORTANT This shower screen / enclosure must be installed by suitably qualified individuals.

More information

FIXED PANEL SLIDER QCI5241

FIXED PANEL SLIDER QCI5241 INSTALLATION INSTRUCTIONS FIXED PANEL SLIDER QCI5241 FRAMELESS PANEL / DOOR / PANEL FRAMELESS DOOR / PANEL QCI5241 REV. 0 Page 1 Certified 06/16/2016 Parts List *Quantities may vary QCI5241 REV. 0 Page

More information

Laminate Cabinet Installation Instructions

Laminate Cabinet Installation Instructions Laminate Cabinet Installation Instructions www.easygaragestorage.com/installation How To Use These Instructions Thank you for your purchase! Please read each step of this manual thoroughly to ensure proper

More information

TOYOTA TUNDRA CARGO DIVIDER Preparation. Part Number: PT

TOYOTA TUNDRA CARGO DIVIDER Preparation. Part Number: PT Preparation Part Number: PT767-34070 Kit Contents 1 1 Divider Screen 2 1 LH Bracket with Warning Label 3 1 RH Bracket without Warning Label NOTE: Part number of this accessory may not be the same as the

More information

Answer Power Beam and Boundary Screen

Answer Power Beam and Boundary Screen Answer Power Beam and Boundary Screen 5/16 MAGNETIC 3/8 If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for immediate action by

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Sheet 1 of 5 General: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the

More information

Footprint Mobile Assembly Instructions

Footprint Mobile Assembly Instructions Footprint Mobile Assembly Instructions 1998754 Revision -1 Complete Series Master Packet If you have any questions concerning these instructions, please call Kimball Office Customer Service. 20 Kimball

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

Curium 19.4H Installation Instructions & Parts List

Curium 19.4H Installation Instructions & Parts List Curium 19.4H Installation Instructions & Parts List Illustration Curium 19.4H Right Hand Page 1 of 21 30/06/2016 Revision 1.0 IMPORTANT This shower screen / enclosure must be installed by suitably qualified

More information

Assembly and installation help

Assembly and installation help Assembly and installation help A supplement to the directions The Purpose of this tutorial is to expand (not replace) upon the directions that come with the system and to help provide shortcuts, the first

More information

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283 FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283 QCI5283 Page 1 Date Certified: 06/16/2016 Parts List with wall mount clamp ITEM NO. DESCRIPTION QTY. 1 FIXED GLASS PANEL 1 2 WALL MOUNT CLAMP 1 3 U-CHANNEL

More information

Diva Acoustical Ceiling

Diva Acoustical Ceiling Installation Instructions Diva Acoustical Ceiling CONTENTS Important User Information...........................2 Safety Precautions.................................3 Required Tools....................................3

More information

Frameless Bypass Slider

Frameless Bypass Slider INSTALLATION INSTRUCTIONS Frameless Bypass Slider QCI-5301 Heavy Glass Bypass Slider with Exposed Rollers QCI5301 Rev 0 Page 1 Certified 11/1/2016 Tools: To install your New Shower Enclosure, you may need

More information

Track Rack. * Track Racks are not lockable

Track Rack. * Track Racks are not lockable The Track Rack s unique staggered, sliding hook design creates the greatest parking efficiency while still providing easy access to any particular bike. When adding or removing a bike to the rack, simply

More information

INSTALLING YOUR NEW SPRING LIFT ARM KIT

INSTALLING YOUR NEW SPRING LIFT ARM KIT INSTALLING YOUR NEW SPRING LIFT ARM KIT 1. Measure the distance that the roof is to be raised. [If your lift system is completely non-functional, you will need to calculate or estimate this distance as

More information

1503 Follow Spot Yoke, Source Four LED

1503 Follow Spot Yoke, Source Four LED 1503 Follow Spot Yoke, Source Four LED Rev 1.0 2016 City Theatrical, Inc. Getting Started with the City Theatrical Follow Spot Yoke for source four LED Congratulations on the purchase of your City Theatrical

More information

P /8 Ring Diameter 90. Trim Ring Mounting Holes P /8. 393/16 Ring Diameter. Stud Minimum

P /8 Ring Diameter 90. Trim Ring Mounting Holes P /8. 393/16 Ring Diameter. Stud Minimum PARTS LIST VARIABLE Top Over Head Support Bracket 1 872070 P4000-SMR Over Head Joiner Bracket 1 VARIABLE Bottom Over Head Bracket 1 79741 P4000-SMR 4 Angled Leg 4 100-00230-14 1/4-20 x 31/2 RD. HD. MS.

More information

Curium 19H Installation Instructions & Parts List

Curium 19H Installation Instructions & Parts List Curium 19H Installation Instructions & Parts List Illustration Curium 19H Right Hand Page 1 of 15 01/07/2016 Revision 2.1 IMPORTANT This shower screen / enclosure must be installed by suitably qualified

More information

Assembly Instructions

Assembly Instructions Unite Panel System Hinge Door July 2016 #12 x / slotted hex washer head bolt Figure 1 threshold bracket frame Detail F threshold bracket threshold bracket (installed) #12 x / slotted hex washer head bolt

More information

Move System Swivel Caster Installation ( )

Move System Swivel Caster Installation ( ) Move System Swivel Caster Installation (002-10265-00) Caution Always disconnect power to chair before removing covers or performing any service procedures. Step 1: Remove Top Cover A) Position chair to

More information

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER INSTALLATION INSTRUCTIONS RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER NOTE: The following instructions provide general guidelines for product installation. For additional information

More information

ASCENT & ASCENT XL AFTERMARKET INSTALLATION MANUAL SLIDE-OUT COVER

ASCENT & ASCENT XL AFTERMARKET INSTALLATION MANUAL SLIDE-OUT COVER AFTERMARKET INSTALLATION MANUAL ASCENT & ASCENT XL RV SLIDE-OUT COVER Read this manual before installing or using this product. Failure to follow the instructions and safety precautions in this manual

More information

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation. metalworks Plank Assembly and Installation Instructions 1. GENERAL is a ceiling system made up of standard sized hook-on planks fabricated from galvanized steel and powder coated to provide a damage and

More information

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013 U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS TOOL LIST Required Tools: - Reciprocating Saw with Metal Cutting Blade - Drill - 7/16 Drill Bit for Metal Drilling -

More information

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP 6-1/4 HANDRAIL W/ VINYL HANDGRIP TYPICAL ASSEMBLY 5 2 BUTT JOINT 12 10 9 1 8 11 6 3 7 4 BUTT JOINT COMPONENT LIST 1 LEFT RETURN 7 UPPER IMPACT ABSORBER 2 RIGHT RETURN 8 LOWER IMPACT ABSORBER 3 OUTSIDE

More information

Tools Required: - Utility knife - 11/16 Deep socket - Ratchet - 11/16 Crescent wrench - Ratchet Extension - 1/4 socket - Electrical tape

Tools Required: - Utility knife - 11/16 Deep socket - Ratchet - 11/16 Crescent wrench - Ratchet Extension - 1/4 socket - Electrical tape DESTROYER FRONT BUMPER INSTALL JL STEP 1 : GATHER YOUR TOOLS AND LAY OUT YOUR PARTS... Tools Required: - Utility knife - 11/16 Deep socket - Ratchet - 11/16 Crescent wrench - Ratchet Extension - 1/4 socket

More information

Assembly Instructions for model: VMPR1

Assembly Instructions for model: VMPR1 Assembly Instructions for model: VMPR1 Congratulations on your purchase! The VMPR1 ceiling mount provides a unique, simplified method of ceiling mounting inverted LCD/DLP projectors. Its low profile design

More information

Gallium 03 Installation Instructions & Parts List

Gallium 03 Installation Instructions & Parts List Gallium 03 Installation Instructions & Parts List Illustration Gallium 03, H1 Handle Left Hand: Open Out 04/05/2016 Revision 1.1 Page 1 of 19 IMPORTANT This shower screen / enclosure must be installed

More information

Assembly Instructions 10 X 10 Aluminum Roof Support

Assembly Instructions 10 X 10 Aluminum Roof Support Assembly Instructions 10 X 10 Aluminum Roof Support Aluminum Roof Support Bolt Package 16-5/16 X 2 ¼ SS Bolt 24-5/16 X 1 SS Bolt 40-5/16 SS Nylon Lock Nuts 16-5/16 SS Flat Washers 28-4 ½ Wood Screws 36-1

More information

Installation Instructions

Installation Instructions Installation Instructions Sleeve Adapter Kit For use with Vert-I-Pak A-Series (9K 18K) Air Conditioner and First Company SPU Series wall sleeve NOTE: The following installation instructions apply to the

More information

INSTALLATION GUIDE. TRANZFORM Sound TRANZFORM Space

INSTALLATION GUIDE. TRANZFORM Sound TRANZFORM Space INSTALLATION GUIDE TRANZFORM Sound TRANZFORM Space Cornell Iron Works, Inc. 100 Elmwood Ave. Crestwood Industrial Park Mountain Top, PA 18707 Phone: 800.233.8366 or 570.474.6773 Fax: 800.526.0841 INSTALLATION

More information

Installation Instructions For TruLine 1.6A 24VDC

Installation Instructions For TruLine 1.6A 24VDC 2014 Pure Lighting. All Rights Reserved. Installation Instructions For TruLine 1.6A 24VDC INS# 902-TL1.6A-07 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.purelighting.com

More information

Installation Instructions

Installation Instructions Installation Instructions For Models: Model Number / Description File Name 1540 Classic Series P-Lam Toilet Partitions 1540.pdf 1 INSTALLATION INSTRUCTIONS LAMINATED PLASTIC TOILET PARTITIONS 1540 Classic

More information

Installation Instructions

Installation Instructions For Medium (15-18.5K) + Heavy duty (-8.5K) Air Conditioner READ BEFORE INSTALLING UNIT To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges

More information

C70 Window Roller Repair Taken from: Heres the problem:

C70 Window Roller Repair Taken from:  Heres the problem: C70 Window Roller Repair Taken from: http://www.volvospeed.com/vs_forum/topic/115086-how-to-c70-window-rollers-permanent-fix/ Heres the problem: This happened to two separate window assemblys on my c70

More information

MESO X1 TBAR SEMI-RECESSED

MESO X1 TBAR SEMI-RECESSED MESO X1 TBAR SEMI-RECESSED 93t-inst PAGE 1 OF 2 1 2 A IMPORTANT Do not remove packaging around fixture until after fixture is installed. The packaging protects and in some cases supports the fixture during

More information

Frameless Inline Door With Return QCI5263

Frameless Inline Door With Return QCI5263 INSTALLATION INSTRUCTIONS Frameless Inline Door With Return QCI5263 WALL MOUNT HINGES FRAMELESS DOOR / PANEL / RETURN PANEL QCI5263 REV. 0 Page 1 Certified 06/17/2016 Parts List with wall mount hinges

More information

VACUSEAL MODEL 200. HOT TUB PRODUCTS 233 Carrington Road Bethany CT

VACUSEAL MODEL 200. HOT TUB PRODUCTS 233 Carrington Road Bethany CT VACUSEAL MODEL 200 J G F G H L HOT TUB PRODUCTS 233 Carrington Road Bethany CT 06524 860-469-2580 www.vacusealcoverlift.com www.hottubproducts.com Made in USA H K E D C I A P B 10 9 8 7 6 5 4 3 2 1 0 SPAS

More information

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview Overview Step 4 Mounting to Structure Page 6 Step 1 Mounting Locations & Rough-Ins Pages 2-3 Step 2 Identification & Preparation Page 4 Step 6 Securing Corner Joints Page 8 Step 3 Opening Luminaires Page

More information

Frameless Inline Door QCI5250

Frameless Inline Door QCI5250 INSTALLATION INSTRUCTIONS Frameless Inline Door QCI5250 FRAMELESS PANEL / DOOR / PANEL QCI0249 REV. 3 Page 1 Certified 10/12/12 Parts List with pivot hinges *Quantities may vary. QCI0249 REV. 3 Page 2

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Furniture Solutions: 68 Shipstation with Storage Shelf Model Numbers: PB001 (D9001, D9010N, D9021, D9030, D9032/D9033, D9098, RC4054) Introduction This document provides the Pitney

More information

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions Overview

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions Overview Overview NOTES All power connections should be installed according to local/national codes by a Certified Electrician. This installation requires proper support as each luminaire is being installed. DO

More information

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS By following the steps outlined below, the assembly, installation and adjustment of the steel doors, will be a simple process. Let s start with the Driver Side.

More information

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill DEVICES COVERED IN THIS DOCUMENT: 4700S Surface Vertical Rod Device 4700SF Fire Exit Surface Vertical Rod Device TOOLS REQUIRED Metal Wood Wood and Metal Screws Sex Bolts #7 Drill ¼ -20 Tap #16 Drill #12-24

More information

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4 Installation Instructions for 90ELED-DIC Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E_L_-L_DI. LED - ROUND/ SQUARE FLANGELESS GENERAL PRODUCT I NFORMATION: This product

More information

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS By following the steps outlined below, the assembly, installation and adjustment of the steel doors, will be a simple process. Let s start with the Driver Side. Note: Having the hood open makes the job

More information

John Deere ME5 Row Unit Kit Installation Manual Kit Number

John Deere ME5 Row Unit Kit Installation Manual Kit Number John Deere ME5 Row Unit Kit Installation Manual Kit Number 768503 955422_01 11/15 1 System Hardware Part Number Description Quantity 768503 John Deere ME5 SpeedTube Row Unit Kit 1 per row The Row Unit

More information

Installation Instructions

Installation Instructions by Plato Woodwork Installation Instructions Plato Woodwork, Inc. 200 Third Street SW P.O. Box 98 Plato, MN 55370 www.platowoodwork.com 800.328.5924 SECTION GUIDE GETTING STARTED PAGE # Installation Methods...

More information

POLYBAG KIT JOINER STRAP FIXTURE TYPE ROLL OF DOUBLE SIDED TAPE REQUIRED FOR R/POSITION WALL ANGLES (SEE STEP 6) 12"LG U-ANGLE (3) U-CLIPS

POLYBAG KIT JOINER STRAP FIXTURE TYPE ROLL OF DOUBLE SIDED TAPE REQUIRED FOR R/POSITION WALL ANGLES (SEE STEP 6) 12LG U-ANGLE (3) U-CLIPS STRAIGHT EXTENSION [SE] P/C PG. OF NOTES: STRAIGHT EXTENSIONS (SE) ARE INSTALLED AT ENDS OF ROW TO CLOSE OFF CEILING OPENING. A. FIXTURES MUST BE INSTALLED PRIOR TO ATTACHING STRAIGHT EXTENSIONS. B. STRAIGHT

More information

Frameless Bypass Slider

Frameless Bypass Slider INSTALLATION INSTRUCTIONS Frameless Bypass Slider QCI-5301 3/8 or 1/4 Glass Bypass Slider with Exposed Rollers QCI5301 Rev 1 Page 1 Certified 6/5/2017 Tools: To install your New Shower Enclosure, you may

More information

Product must be installed as shown using the screws and brackets provided. Use of incorrect hardware could result in damage to the product.

Product must be installed as shown using the screws and brackets provided. Use of incorrect hardware could result in damage to the product. General Notes These installation instructions are intended to be comprehensive for a typical Keyeira/Presto configuration. Your configuration may differ. If you have questions contact Geiger Customer Service

More information

Hardware and Components:

Hardware and Components: Hardware and Components: (A) 5/16 x 2 Hex Bolt (B) 5/16 x 2-1/4 Hex Bolt (C) 5/16 x 2-1/2 Hex Bolt (D) 4X 5/16 x 3/4 Hex Bolt (E) 4X 5/16 x 1-1/4 Hex Bolt (F) 11X 5/16 Flat Washer (G) 12X 5/16 Nylock Nut

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Trans4mer Grille Guard/Winch Mount For Chevrolet Silverado 1500HD & 2500 Kit 68162 This WARN Trans4mer system can be customized to give your Chevy Silverado a wide variety of

More information

OXYGEN INSTALLATION. Revision date

OXYGEN INSTALLATION. Revision date 12345 1 Hardware List 12345 Flat head wood screw #9 x 7/8 long with #2 Phillips drive, silver Used to attach surfaces and end panels Hex set screw ½-13 x 2 long with 1/4 hex drive, black Used on Legs Hex

More information

Installation And Care Instructions. Vertical Honeycomb Shades

Installation And Care Instructions. Vertical Honeycomb Shades Installation And Care Instructions Vertical Honeycomb Shades Rev 5/2013 Table Of Contents Getting Started... 3 Parts Overview... 4 Materials Required... 5 Tools Required... 6 Outside Mount Installation...

More information

HP-2 Recessed Wall Wash Flush Diffuser Tech Zone 4" Starter/Independent Installation Instructions

HP-2 Recessed Wall Wash Flush Diffuser Tech Zone 4 Starter/Independent Installation Instructions HP-2 Recessed Wall Wash Flush Tech Zone /Independent Scan QR code for helpful video(s) Step 1 Step 2 Tech Zone Collection. Center-to-center spacing Wall 0-10V Dimming.0.0.0 Tech Zone (C1) Tech Zone (C2)

More information