Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:"

Transcription

1 Application: Tag: Project: Location: Date: Engineer: Contractor: Architect: Submitted by: The ABV Automatic maintains a constant airflow volume in HVAC applications. The highly engineered damper blade is calibrated to automatically adjust to varying pressures using physics, not electricity, making the ABV truly pressure independent. R38089 The ABV can be used in any HVAC application where a precise volume of air (CFM) is required regardless of varying static pressures. The ABV can be used in both supply and exhaust applications. Standard Construction: FRAME: Reinforced UL 94 Thermoplastic Resins BLADE: Reinforced UL 94 Thermoplastic Resins BEARINGS: Hydraulic blade dampener for extremely quiet operation OUTER SEAL: Removable rubber gasket-type around circumference of damper SPRING: Stainless steel leaf type TEMPERATURE RANGE: 2 F (-4 C) to 10 F (6 C) ANTI-MICROBIAL AGENT: Steri-Balance infused into plastic ADAPTER: Quick-connect adapter ring for square ducts included Performance: AIRFLOW ADJUSTER: Hand-operated manual set-point adjuster (no tools needed) PRESSURE OPERATING RANGE: 0.2" WC (0 Pa) to 2.0" WC (498 Pa) UL STANDARD MET: Classified by UL to UL 2043 for heat and visible smoke release (UL File R38089) ACCURACY: +/- 10% of set CFM Airflow Range by Model Size: Model Diameter* Individual Manual Set Points Airflow Range (CFM)** ABV-4 4" (102) 20 2 to 130 ABV- " (127) 20 2 to 130 ABV-6 6" (12) 24 0 to 27 *Dimensions shown in inches, parentheses () indicate millimeters. **Note: Airflow range determined through +/- 10% of average airflow over 0.2" to 1" W.C. Configurations Available: Square/Rectangular to Round Transition (see page ) Grille Mount Box with Flange (see page 6) ABV & UL Fire Damper Assembly (see page 7) ABV & Wood Truss Ceiling Radiation Damper in Rated Boot Assembly (see pages 8-9) 1 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

2 PERFORMANCE DATA - Model ABV MODEL ABV SET POINTS CFM 30 CFM 3 CFM 4 CFM 0 CFM 60 CFM 7 CFM 60.0 CFM 90 CFM CFM PRESSURE (inches/wg) MODEL ABV SET POINTS CFM 30 CFM 3 CFM 4 CFM 0 CFM 60 CFM 7 CFM 60.0 CFM 90 CFM CFM PRESSURE (inches/wg) CFM MODEL ABV SET POINTS CFM 60 CFM 7 CFM 90 CFM 10 CFM 120 CFM 13 CFM 10 CFM 180 CFM 20 CFM PRESSURE (inches/wg) Performance Notes: PL-1 PL-2 PL-4 10D min. PL-Z Units tested in accordance with AMCA 00-D-12 - Figure.1. D ± 0.02D Device Being Tested To Exhaust System & Flow Measuring Section 2 As part of our continuous improvement program, we reserve the right to make further improvements without notice. P s4 Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

3 Dimensional Data: Model ABV Model Length (L)* Inner Diameter (ID)* Outer Diameter (OD)* Outer Diameter w/ Gasket (ODG)* Adapter Plate Height (H)* *Dimensions shown in inches, parentheses () indicate millimeters. **Weight shown in lbs., parentheses () indicate kilograms. Adapter Plate Width (W)* Weight** ABV " (88.) 3.37" (8.6) 3.66" (92.96) 4.1" (104.14) 3.90" (99.06) 4.00" (99.) 0.2 (.11) ABV- 3.72" (94.49) 3.37" (8.6) 4.81" (122.17).02" (127.1) 4.91" (124.8) 4.91" (124.8) 0.43 (.20) ABV-6.29" (134.27).29" (134.28).66" (143.76) 6.1" (14.94).91" (10.2).91" (10.2) 0.48 (.22) Calibration: Each ridge of the set-point adjustment indicator has been laboratory calibrated and tested in accordance with ANSI/AMCA 00-D-12 Figure.1 (see Figures 1 and 2) Each ridge is lab proven to deliver a flow rate within 10% of the set point Please consult factory for set-point ridges that are not labeled with a value NOTE: A ridge between two values may NOT necessarily be the average of the two. Adjustment: Adjusting of the ABV can be conveniently done by sliding the setpoint indicator on the face of the damper (see Figures 1 and 2) No tools needed to adjust the set-point of the ABV All lab-calibrated intervals represent the applicable CFM that will remain constant within +/- 10% of the set CFM Operation: All ABV models are easily reversible for use in both exhaust and supply applications (see Figures 3 and 4) NOTE: Airflow direction arrows on the product must be adhered to in order to assure proper operation All ABV models are supplied with a patent pending Quick Connect Adapter Ring that allows the ABV to be quickly and easily installed in the field into square duct All ABV models are also supplied with a removable rubber gaskettype seal around the circumference of the damper for a tight fit into rigid round duct NOTE: This gasket can be removed and switched to the opposite side for a supply application Figure 1 (4" and " set points shown) Figure 2 (6" set points shown) Figure 3 Figure 4 3 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

4 Suggested Specifications: Model ABV Furnish and install as shown on plans and/or schedules Model ABV Automatic by Automatic Airflow Balancing (AAB), Clearwater, FL. Unit shall respond to changes in duct pressure automatically without the need for power supply. All units shall incorporate a hand-operated manual set-point adjustment feature that facilitates field adjustment of flow rate set point without the use of tools, and allows adjustment while the automatic balancing valve is installed. All set points shall operate within ±10% of airflow set point. Individual set points shall be laboratory calibrated and verified through testing in accordance with AMCA 00-D-12. Each ABV shall be manufactured of reinforced thermoplastic resins and shall be classified per UL 2043 and must be labeled as such. Each unit shall be rated for use in air temperature ranging from 2 F to 10 F. All automatic balancing valves shall incorporate Steri-Balance antimicrobial agent to prevent organic growth. Each ABV shall utilize a hydraulic blade dampener to prohibit blade rattle. ABV valves shall be provided with a full circumference rubber gasket to provide tight seal when inserted in round duct, or for tight sealing when used in conjunction with an accompanying quick-connect adapter ring in square duct applications. Features & Benefits: 1. Oil-filled, hermetically sealed bearings for silent blade operation 2. Detachable adapter plate for square/ rectangular duct mounting (adapter plate can be moved to opposite side for supply applications) 3. Reversible design allows for use in supply or exhaust applications (NOTE: Arrow must coincide with direction of airflow) 4. Removable rubber gasket for tight seal in round rigid duct. Anti-microbial agent Steri-Balance infused into plastic 6. Tool-free set-point adjustment (depending on model) individual set-points " Model shown As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

5 ABV - S/R Transition: All ABV models can be supplied with a square or rectangular transition (-S/R model). This transition will allow for inserting into square/rectangular duct or sleeve. The S/R transition can be removed and flipped to the other side of the ABV using the quick adapter plate (in some cases, tabs and screws will be used in place of adapter plate due to space constraints). Models: S/R Transitions: ABV-4-S/R 4" x 4" 8" x 4" 10" x 4" Other: x ABV--S/R 6" x 4" 8" x 6" 10" x 8" ABV-6-S/R 6" x 6" 8" x 8" 10" x 10" ABV-4-S/R (Legs Turned Out) ABV-4-S/R (Legs Turned In) 4" Model with 6" x 6" transition shown. 4" Model with 6" x 6" transition shown. 1" (2) 1" (2) As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

6 GM - Grille Mount Box: Model ABV All ABV models can be supplied with a flanged Grille Mount Box. This box will allow for the insertion of a standard depth grille (see grille options on next page). The ABV can be flipped around for supply applications by removing the Quick Adapter Plate, turning the ABV around (so that the set points are on the opposite side) and re-attaching the adapter plate. NOTE: Non-flanged Grille Boxes available. Please contact an AAB representative. Models: ABV-4 with Grille Mount Box ABV- with Grille Mount Box ABV-6 with Grille Mount Box Box Size (Grille Opening) " Width x " Height ABV-4 with Grille Mount Box.7" 1.0" DIM B DIM A DIM C ABV-Model Sleeve Size Dimension A Dimension B Dimension C ABV-4 6" x 6" (12 x 12) 7.20" (182.22) 3.44" (87.38).7" (146.0) ABV- 6" x 6" (12 x 12) 7.20" (182.22) 3.72" (94.49).7" (146.0) ABV-4 8" x 8" (203 x 203) 9.20" (233.68) 3.44" (87.38) 7.7" (196.8) ABV- 8" x 8" (203 x 203) 9.20" (233.68) 3.72" (94.49) 7.7" (196.8) ABV-6 8" x 8" (203 x 203) 9.20" (233.68).22" (1.9) 7.7" (196.8) ABV-4 10" x 10" (24 x 24) 11.20" (284.48) 3.44" (87.38) 9.7" (247.6) ABV- 10" x 10" (24 x 24) 11.20" (284.48) 3.72" (94.49) 9.7" (247.6) ABV-6 10" x 10" (24 x 24) 11.20" (284.48).22" (1.9) 9.7" (247.6) ABV-4 12" x 12" (30 x 30) 13.20" (33.28) 3.44" (87.38) 11.7" (298.4) ABV- 12" x 12" (30 x 30) 13.20" (33.28) 3.72" (94.49) 11.7" (298.4) ABV-6 12" x 12" (30 x 30) 13.20" (33.28).22" (1.9) 11.7" (298.4) Dimensions shown in inches, parentheses () indicate millimeters. Note: Common Grille/Sleeve sizes shown. Contact AAB for sizes not shown. 6 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

7 ABV and Fire Damper in UL Rated Assembly: All ABV models can be supplied with a UL rated fire damper as a UL Rated and Approved assembly. This assembly will include an ABV, flanged sleeve, fire damper and optional grille (see grille options within this submittal). The ABV can be flipped around for supply applications and re-secured using supplied tabs or adapter plate (depending on the size). This assembly must be installed per the fire damper manufacturer s installation instructions. NOTE: Non-flanged Grille Boxes available. Please contact an AAB representative. Models: ABV-4 with Fire Damper Assembly ABV- with Fire Damper Assembly ABV-6 with Fire Damper Assembly Options: ABV ABV-4 with UL Fire Damper Assembly: R38089 R8218 Fire Damper: Dynamic Fire Damper (standard for models 6"x 6" or larger) Horizontal* Vertical S/R Transition (tab or adapter plate depends on size) Static Fire Damper (standard for models 6 x 6 or smaller) Horizontal* Vertical.7" (19) Sleeve: Flanged (standard) No Flange DIM C Flanged Sleeve Slimline Fire Damper DIM A DIM B Special Notes: Grille (optional) *If installing horizontally, the ABV must be below the fire damper within the assembly. ABV-4 model shown above with 4" x 4" static fire damper and grille box. ABV-Model Sleeve Size Dimension A Dimension B Dimension C¹ ABV-4 4" x 4" (102 x 102).29" (134.37) SQ 8.8" (217.88) 3.9" (100.23) SQ ABV-4 6" x 4" (12 x 102) 7.29" (18.17) x.29" (134.37) 8.8" (217.88).9" (11.13) x 3.9" (100.23) ABV-4 6" x 6" (12 x 12) 7.29" (18.17) SQ 8.8" (217.88).9" (11.13) SQ ABV- 6" x 6" (12 x 12) 7.29" (18.17) SQ 8.86" (224.99).9" (11.13) SQ ABV-6 6" x 6" (12 x 12) 7.29" (18.17) SQ 10.36" (263.09).9" (11.13) SQ ABV-4 8" x 6" (203 x 12) 9.29" (23.97) x 7.29" (18.17) 8.8" (217.88) 7.9" (201.93) x.9" (11.13) ABV- 8" x 6" (203 x 12) 9.29" (23.97) x 7.29" (18.17) 8.86" (224.99) 7.9" (201.93) x.9" (11.13) ABV-6 8" x 6" (203 x 12) 9.29" (23.97) x 7.29" (18.17) 10.36" (263.09) 7.9" (201.93) x.9" (11.13) ABV-4 8" x 8" (203 x 203) 9.29" (23.97) SQ 8.8" (217.88) 7.9" (201.93) SQ ABV- 8" x 8" (203 x 203) 9.29" (23.97) SQ 8.86" (224.99) 7.9" (201.93) SQ ABV-6 8" x 8" (203 x 203) 9.29" (23.97) SQ 10.36" (263.09) 7.9" (201.93) SQ Dimensions shown in inches, parentheses () indicate millimeters. NOTE: Common Sleeve sizes shown. Contact AAB for sizes not shown. ¹Opening for ABV and Fire Damper assembly should be framed larger than these listed dimensions (see manufacturer s installation instructions). 7 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

8 ABV and Wood Truss Ceiling Radiation in Rated Boot Assembly: All ABV models can be supplied with a UL 263 rated wood truss ceiling radiation damper and boot assembly. This assembly will include an ABV in the supply or exhaust orientation, un-insulated 90 degree or straight sheet metal boot, Warnock-Hersey approved wood truss ceiling radiation damper and optional grille (see grille options within this submittal). The ABV is bi-directional and can always be flipped around from supply to exhaust applications, or vice versa, and re-secured within the neck of the sheet metal boot. See next page for a 90 degree insulated boot assembly. This assembly must be installed per the ceiling radiation damper manufacturer s installation instructions. NOTE: Wood truss CRD boots typically supplies with flanges for boot rail installation. Non-flanged wood truss CRD boots are available. Please contact AAB representative. ABV Models: ABV-4 ABV- ABV-6 Application: Supply Exhaust WT Ceiling Radiation Damper Boot Models: See NCA Manufacturing ( Submittals for dimensional information and approved ceiling designs on below models: CDH-S/R-90-F (90 degree un-insulated boot with boot rail flanges) CDH-S/R-90 (90 degree un-insulated boot without boot rail flanges) CDH-S/R-ST-F (Straight un-insulated boot with boot rail flanges) CDH-S/R-ST (Straight un-insulated boot without boot rail flanges) ABV-6 with Wood Truss Ceiling Radiation Damper Boot Assembly: Boot/Damper Size: " width x " height x " diameter NOTE: Width and Height dimensions are the grille opening and can be interchanged (i.e. WxH is same as HxW). NOTE: 10x6x6 CDH-S/R-90-F with 6" ABV-6 Shown in the supply orientation. If in the exhaust orientation, the setpoint ridge will be accessible from grille opening. CDH-S/R-ST- F D 1/8" (3) 2" CDH-S/R-90-F Varies - See Submittal 2" (1) D-1/8" (3) Varies - See Submittal Varies - See Submittal 6" 2-1/2" (64) 1/2" (13) 2-½" 1" (2) LISTED SIZE W x H 1" (2) 1" LISTED SIZE W x H ½" 8 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

9 ABV and Wood Truss Ceiling Radiation in Rated Boot Assembly: All ABV models can be supplied with a UL 263 rated wood truss ceiling radiation damper and boot assembly. This assembly will include an ABV in the supply or exhaust orientation, insulated 90 degree sheet metal boot, Warnock-Hersey approved wood truss ceiling radiation damper and optional grille (see grille options within this submittal). The ABV is bi-directional and can always be flipped around from supply to exhaust applications, or vice versa, and re-secured within the neck of the sheet metal boot. See previous page for a 90 degree un-insulated boot assembly. This assembly must be installed per the ceiling radiation damper manufacturer s installation instructions. NOTE: This insulated wood truss ceiling radiation damper damper boot will be supplied with flanges for boot rail installation only. ABV Models: ABV-4 ABV- ABV-6 Application: Supply Exhaust WT Ceiling Radiation Damper Boot Models: See NCA Manufacturing ( Submittals for dimensional information and approved ceiling designs on below models: ABV-6 with Insulated Wood Truss Ceiling Radiation Damper Boot Assembly: CDH-S/R-90-IB (90 degree insulated boot with boot rail flanges) Boot/Damper Size: " width x " height x " diameter NOTE: Width and Height dimensions are the grille opening and can be interchanged (i.e. WxH is same as HxW). 3-1/2" (89) CDH-S/R-90-I B LISTED SIZE + 3" (76) NOTE: 6x10x6 CDH-S/R-90-IB with 6 ABV-6 Shown in the supply orientation. If in the exhaust orientation, the set-point ridge will be accessible from grille opening. D-1/8" (3) Varies - See Submittal 2-1/2" (64) W H 1/2" (13) 1" (2) LISTED SIZE W x H 1" (2) 9 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

10 Grille Options: MODEL: RH-1 (Return Grille - Surface Mount - Roll Formed Aluminum) GASKET Listed Size Listed Size GASKET 8 Listed Size + 2 Face View (RH-1 Model) MODEL: SRH-1 (Return Grille - Surface Mount - Roll Formed Steel) Listed Size*- 3 8 Ø 3 Mounting Holes 16 (Countersunk) Listed Size*+ 2 8 Face View (SRH-1 Model) MODEL: CC-1 (Sidewall/Ceiling Return Grille - Surface Mount - Extruded Aluminum) Duct Size = Listed Size Listed Size Listed Size ½ x ½ x ½ Cube Core ½ x ½ x ½ Cube Core 8 Face View MODEL: RHE-1 (Return Grille - Surface Mount - Extruded Aluminum) Listed Size*- 1 4 Listed Size*+ 2 Mounting Holes (Countersunk) 8 Face View (RHE-1 Model) 04 Clear Anondized 10 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

11 Grille Options: Listed Size Listed Size Mounting Holes 3/16 Diameter (Countersunk) Listed Size Face View Listed Size Listed Size Mounting Holes 3/16 Diameter (Countersunk) Listed Size Face View Listed Size Listed Size Listed Size Mounting Holes 3/16 Diameter (Countersunk) Front View (H Model) Horizontal Blades Listed Size Listed Size Listed Size Mounting Holes 3/16 Diameter (Countersunk) Front View (V Model) Vertical Blades 11 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL

MR Modulo Adjustable Constant Airflow Regulator

MR Modulo Adjustable Constant Airflow Regulator & ZONE CONTROLS Adjustable Constant Airflow Regulator PRODUCT SPECIFICATIONS & TECHNICAL DATA Construction 5 4 1 GENERAL The model Adjustable Constant Airflow Regulator is a modulating orifice that automatically

More information

Submittal Sheet COUNTERSUNK HOLES SDG SPIRAL DUCT GRILLE 1 7/8" (47) + 1 1/4" (32) - 3/4" (19) ( DUCT OPENING ) END GASKET NOM. LENGTH - 3/4" (19) OPTIONAL AIR SCOOP AIR SCOOP (ROD OPERATOR) NOM. LENGTH

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES Model 49-240 Model 48LL1 Model 49-280 Model 49-480 Model 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance.

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION SECTION 15190 MECHANICAL IDENTIFICATION PART 1 GENERAL 1.01 SECTION INCLUDES A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe Markers. 1.02 SUBMITTALS A. Submit valve chart and schedule,

More information

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS Sealing of fibrous glass duct board to the sheet metal sleeve must be made with glass fabric and mastic, except where operating pressure is less than

More information

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 53 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Tags. 3. Stencils. 4. Pipe markers. 5. Ceiling tacks. 6. Labels. 7. Lockout

More information

BC-SERIES Screw-Jack Pedestal for Creative Design. Specifications text. Menu. Page 1/7

BC-SERIES Screw-Jack Pedestal for Creative Design. Specifications text. Menu.  Page 1/7 Specifications text BC Series Screwjack Pedestal 3rd Generation Menu Introduction of the BC series 1 Pedestal 1.1 Head 1.2 Base 2 Sleeve 3 Tabs 4 Lock 5 Slope corrector PH5 6 Slope corrector BC-PH5 7 Reverse

More information

Ford Water Meter Couplings & Accessories

Ford Water Meter Couplings & Accessories Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information

Complete O.D. Machining in One Operation

Complete O.D. Machining in One Operation MFDODM209 Complete O.D. Machining in One Operation Including: Hydra-Drive For Extreme Accuracy CREATING INNOVATIONS IN FACE DRIVING TECHNOLOGY www.facedrivers.com Complete O.D. Machining in one Operation

More information

MP918B UL Listed Damper Actuator

MP918B UL Listed Damper Actuator UL Listed Damper Actuator BEFORE INSTALLATION The UL Listed Pneumatic Damper Actuator is used for control of Leakage Rated (Smoke) Dampers, classified under Underwriters Laboratories (UL) Standard 555S,

More information

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Product Guide Specification

Product Guide Specification Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat,

More information

Facility Services Subgroup Preface for Divisions 21` through 28

Facility Services Subgroup Preface for Divisions 21` through 28 Facility Services Subgroup Preface for Divisions 21` through 28 1.1 EXECUTIVE SUMMARY A. This document provides standards for the Consultants and Contractors producing mechanical and electrical design

More information

25 / 35 / 45. Rectangular Duct Connection System. Strong and Virtually Leak Free. Simple to install No additional sealing required

25 / 35 / 45. Rectangular Duct Connection System. Strong and Virtually Leak Free. Simple to install No additional sealing required D U C T M A T E 25 / 35 / 45 Rectangular Duct Connection System Strong and Virtually Leak Free Simple to install No additional sealing required Available in specialty metals Consistent connections 25 /

More information

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL SECTION 23 00 10 - MECHANICAL SCOPE OF WORK PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01

More information

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section. SECTION 23 31 13 METAL HVAC DUCTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in

More information

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions Dimensions Class Bronze Dimensions Meets Ib. A.S.M.E. Stard Class 00 Bronze Dimensions Meets ANSI STD B. Nominal Dim. A O.D. Dim. B Circle Dim. C Hole No. Holes Nominal Dim. A Diam. Dim. B Min. Dim. C

More information

HALDEMAN, INC. BRAND: RUSKIN. Fire Dampers. IBD20 Deduct 1/4 Inch. Model:

HALDEMAN, INC. BRAND: RUSKIN. Fire Dampers. IBD20 Deduct 1/4 Inch. Model: LEMN, INC. REPS v.. RN: RUSKIN Fire ampers Model: FRME: MOUNTING: FUSELINK TEMP: SLEEVE/TRNS: SLEEVE LENGT: SLEEVE GUGE: SLV MTERIL: MOUNTING NGLES: NGLE IM/G: I0 educt / Inch STYLE VERTICL EGREES SLEEVE

More information

GRILLE AND REGISTER OPTIONS AND ACCESSORIES

GRILLE AND REGISTER OPTIONS AND ACCESSORIES GRILLE ND REGISTER OPTIONS ND CCESSORIES PRODUCT OVERVIEW OPTIONS ND CCESSORIES FOR FSTENING ND MOUNTING FRMES Up to four methods of fastening available for most models. Sub-frame available for professionally

More information

EBTRON a measurable difference!

EBTRON a measurable difference! GP1, HP1 AND SP1 DUCT AND PLENUM PROBE INTERNAL MOUNT INSTALLATION OVERVIEW This document provides the instructions necessary to install Internal Mount Probes as shown in Figure 1. Internally mounted probes

More information

KCR-R CONSTANT AIR VOLUME FLOW REGULATOR

KCR-R CONSTANT AIR VOLUME FLOW REGULATOR KCR-R CONSTANT AIR VOLUME FLOW REGULATOR Intended use: The regulator can be used in both intake and exhaust ventilation ducts. Made of M1 class plastic. Operating range up to 60 C Desription: The constant

More information

EBTRON a measurable difference!

EBTRON a measurable difference! GP1, HP1 AND SP1 DUCT AND PLENUM PROBE INSERTION MOUNT INSTALLATION Document Number 930-0030 OVERVIEW This document provides the instructions necessary to install Standard insertion mount probes as shown

More information

PIPE/CONDUIT SUPPORTS

PIPE/CONDUIT SUPPORTS PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120

More information

SECTION SWINGING AUTOMATIC ENTRANCES

SECTION SWINGING AUTOMATIC ENTRANCES SECTION 084229.33 SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO IR/DOR-O-MATIC SENIOR SWING & ASTRO SWING OPERATOR PART 1-GENERAL 1.01 DESCRIPTION A. This section

More information

The EDGE Self-Sealing Round Duct System

The EDGE Self-Sealing Round Duct System The EDGE Self-Sealing Round Duct System Stamped Fittings, Inc., 217 Lenox Ave., Elmira Heights, NY 14903 Ph: 607.733.9988 www.stampedfittings.com Submittal Sheet The EDGE Features, Benefits & Materials

More information

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of

More information

Thru Wall Floor Seals For New Installation

Thru Wall Floor Seals For New Installation The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or

More information

C U S TO M I Z A B L E S P E C I F I C AT I O N C L I P S AVA I L A B L E AT M I D D L E AT L A N T I C.COM

C U S TO M I Z A B L E S P E C I F I C AT I O N C L I P S AVA I L A B L E AT M I D D L E AT L A N T I C.COM 96-055M / rev 9 / 2-22-12 AXS System For Millwork & In-Wall EXCEPTIONAL SUPPORT & PROTECTION US Patent # 5, 443, 312 EIA/TIA Compliant The AXS system allows an entire bay of equipment to pull out for easy

More information

UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 55 80.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE

More information

19-in. Mini-Rack Cabinet, Type 1

19-in. Mini-Rack Cabinet, Type 1 Spec-00466 19-in. DP FX (763) Mini-Rack 422-2588 422-2661 Cabinet, Components and Accessories Free-Stand Networking Cabinets 19-in. Mini-Rack Cabinet, Type 1 Industry Standards NEMA Type 1 EIA 310-D /

More information

GENERAL ISOMETRIC LAYOUT

GENERAL ISOMETRIC LAYOUT EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE GATE LID CARBATHAN HG 0 WEB GRAY LOWER PAN GRATING ALUMINUM WIPER WALL CARBATHANE HG, 90 GRAY STRUCTURAL SPECIFICATIONS:. FLOODGATE MATERIAL TO BE ALUMINUM

More information

PORTA-FAB Cleanroom Wall Systems

PORTA-FAB Cleanroom Wall Systems PORTA-FAB Cleanroom Wall Systems FABLINE BATTEN 2000 INSTALLATION INSTRUCTIONS IMPORTANT Porta-Fab Advises A Thorough Reading of These Instructions Before Beginning Installation. INTRODUCTION Porta-Fab

More information

Installation and Maintenance Manual IM 770-1

Installation and Maintenance Manual IM 770-1 Installation and Maintenance Manual IM 770-1 Group: Applied Air Systems Part Number: IM 770 Date: March 2014 Skyline Outdoor Air Handler Roof Curb Table of Contents General Description... 3 Curb-Ready

More information

Exterior Vinyl Railings

Exterior Vinyl Railings Exterior Vinyl Railings Exterior Vinyl Railings S O L U T I O N S Series 3000 and 3250 Highest quality low-maintenance PVC Quick snap screw covers Easy-to-assemble components ADA compliant secondary rail

More information

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to ORDER LENGTH codes B through F; code A has 22 adjustment. UL / FM MUELLER Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also, the Indicator

More information

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Nameplates. B. Tags. C. Stencils. D. Pipe Markers. 1.2 RELATED REQUIREMENTS A. Section 099123 - Interior

More information

Contemporary Collection

Contemporary Collection HZ5E Gas Fireplace Model HZ5E-NG1 HZ5E-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.9 kpa) Manifold

More information

Installation Instructions

Installation Instructions edium + Heavy duty READ BEFORE INSTALLING UNIT Preliminary instructions: 1. Check window opening size: the mounting parts furnished with this air conditioner are made to install in a wooden sill double-hung

More information

Liquid Level Detector

Liquid Level Detector Liquid Level Detector Made in the USA MERCURY & LEAD FREE, MERCURY & LEAD FREE, NON-MECHANICAL NON-MECHANICAL 12 MILLION OPERATIONS Combining new technology with a familiar device, the Opti-Float level

More information

Residential & Industrial Fence

Residential & Industrial Fence Residential & Industrial Fence Assembly Instructions CONTENTS 02: OVERVIEW & CONTENTS 03: PRODUCT SPECIFICATIONS 04: GETTING STARTED 05: WALL ATTACHMENT & LINE POST ASSEMBLY 06: CORNER POST ASSEMBLY 07:

More information

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment

More information

Post & Rail. Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail POST SUPPORT OPTIONS

Post & Rail. Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail POST SUPPORT OPTIONS Post & Rail Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail STAGGER RAIL ENDS FOR GREATER STRENGTH ALLOW 1-1/2" GAP ON HINGE SIDE OF GATE AND 1-1/4" ON LATCH SIDE OF GATE HARDWARE DIG HOLES 30" MINIMUM

More information

COMMERCIAL KITCHEN HOOD WORKSHEET/ CHECKLIST

COMMERCIAL KITCHEN HOOD WORKSHEET/ CHECKLIST COMMERCIAL KITCHEN HOOD WORKSHEET/ CHECKLIST Two copies of this worksheet/checklist must accompany plans sets submitted with commercial kitchen application. The applicant is responsible for assuring the

More information

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS Please read and save these installation instructions. MODEL NO.: DOTR12CWIV/DOTR12CBIV P/N: 3828W5U0202 YOUR SAFETY FIRST Read this entire manual

More information

1. ANSI/ASME Standard B , Square and Hex Bolts and Screws, Inch Series

1. ANSI/ASME Standard B , Square and Hex Bolts and Screws, Inch Series SECTION 31 66 13 HELICAL PILES AND HELICAL ANCHORS PART 1 - GENERAL 1.1 DESCRIPTION A. This work pertains to furnishing and installing Helical Piles and Bracket Assemblies shown in the Contract in accordance

More information

LAN Locker Adjustable Shelves

LAN Locker Adjustable Shelves Adjustable Shelves LAN LOCKER ADJUSTABLE SHELVES * Adjustable Shelves are available for LAN LOCKER widths: 24, 30, 48, 60, and 72. * When installing more than one Adjustable Shelf, it is recommended that

More information

Sash Replacement Guide for Andersen Impact Resistant Casement Windows

Sash Replacement Guide for Andersen Impact Resistant Casement Windows Replacement Guide Replacement Guide for Andersen Impact Resistant Casement Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles. INSUL-FLUE OWNER S MANUAL (6 inch) High Heat Resistant Thimble and Insulating Sleeve for Smoke Pipe When Passing Through Any Combustible Wall September 1993, Revision A INTRODUCTION CONGRATULATIONS ON

More information

Adhesive Air Terminal Bases. Universal Surface Bases. Offset Parapet Air Terminal Bases. Section 3.2. Air Terminals & Air Terminal Bases

Adhesive Air Terminal Bases. Universal Surface Bases. Offset Parapet Air Terminal Bases. Section 3.2. Air Terminals & Air Terminal Bases equipment catalog 3-5 Bases Adhesive Bases Used for mounting on membrane or built-up roofs. Mounted with adhesive or plastic roofing cement. The cast base has a mechanical conductor connector. BS-C-3/8ID-ADH-AT

More information

Ford Couplings For Pipe And Tubing

Ford Couplings For Pipe And Tubing Section J 6/2002 Ford Couplings For Pipe And Tubing The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information

Installation Instructions

Installation Instructions For Medium (15-18.5K) + Heavy duty (22-28.5K) Air Conditioner READ BEFORE INSTALLING UNIT To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp

More information

SPLIT FRAME CUTTING & BEVELING MACHINES

SPLIT FRAME CUTTING & BEVELING MACHINES SPLIT FRAME CUTTING & BEVELING MACHINES 1-48 WWW.BBPIPETOOLS.COM 713-747-8502 B&B Pipe & Industrial Tools 527 Michigan St South Houston, TX 77587 SPLIT FRAME CUTTING & BEVELING Portable O/D Locking Cold

More information

MOUNT KIT PERSONAL PLOW. Jeep Liberty Installation Instructions. CAUTION Read this document before installing the snowplow.

MOUNT KIT PERSONAL PLOW. Jeep Liberty Installation Instructions. CAUTION Read this document before installing the snowplow. April 1, 2008 Lit. No. 28429, Rev. 02 3713-1 MOUNT KIT PERSONAL PLOW Jeep Liberty 2002-07 Installation Instructions Read this document before installing the snowplow. See your sales outlet/web site for

More information

Installation Instructions For Heavy Duty (FAS Models) and Median (FAM Models) Air Conditioners

Installation Instructions For Heavy Duty (FAS Models) and Median (FAM Models) Air Conditioners Installation Instructions For Heavy Duty (FAS Models) and Median (FAM Models) Air Conditioners Please read ALL instructions before installing. Two people are recommended to install this product. If a new

More information

Ford Pick Up Rear leaf Spring Kit Installation Instructions

Ford Pick Up Rear leaf Spring Kit Installation Instructions 1948-1956 Ford Pick Up Rear leaf Spring Kit Installation Instructions 1-800-984-6259 www.totalcostinvolved.com Parts 48 inch leaf (2) springs (4) U-bolts 3/8-24 x l 1/4bolts (16) & nuts (2) 1/2-20 x 4

More information

Part No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg)

Part No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg) ttachments Fig. 3199R - eiling Flange Fig. 3199RT - eiling Flange ura-opper oated Size Range: 3 /8"-16 & 1 /2"-13 rod Material: Malleable Iron (Stainless Steel Type 304 available) Standard 3199RT is UR-OPPER

More information

INSTALLATION MANUAL FOR STAINLESS STEEL, GROOVE-END, FLEXIBLE COUPLINGS

INSTALLATION MANUAL FOR STAINLESS STEEL, GROOVE-END, FLEXIBLE COUPLINGS PIEDMONT PACIFIC CORPORATION INSTALLATION MANUAL FOR STAINLESS STEEL, GROOVE-END, FLEXIBLE COUPLINGS 4703 Tidewater Ave., Suite G Oakland. CA, 94601, USA Ph: +1 510 434 0990 / Fax: +1 510 436 0990 www.piedmontpacific.com

More information

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L

FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L I NSTA LL AT IO N & OPER AT I ON M AN UA L FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I OM F L-1 0/ FL- 15 /FL-20 /FL-25/FL-3 0 FlowBar Installed During Hard Ceiling

More information

In-Tube Motorized SCREEN-PRO. All Season Roll-Up Doors IN-JAMB MOUNTING METHOD INSTALLATION INSTRUCTIONS READ THIS FIRST

In-Tube Motorized SCREEN-PRO. All Season Roll-Up Doors IN-JAMB MOUNTING METHOD INSTALLATION INSTRUCTIONS READ THIS FIRST In-Tube Motorized SCREEN-PRO All Season Roll-Up Doors IN-JAMB MOUNTING METHOD INSTALLATION INSTRUCTIONS READ THIS FIRST Carefully examine the crate(s) for damage before opening. If the carton is damaged,

More information

Installation Instructions for New Construction. Installation Instructions for New Construction

Installation Instructions for New Construction. Installation Instructions for New Construction Installation Instructions for New Construction Installation Instructions for New Construction Step 1: Receipt and Inspection of Material Step 2: Banding Preparation Step 3: Parallel Band Installation Step

More information

Concealed Thru-Roof Assemblies

Concealed Thru-Roof Assemblies Concealed Thru-Roof Assemblies IPC s concealed thru-roof assembly is ideal for new constructions or applications where installation will be concealed. The 240 assembly includes everything necessary for

More information

SAWS, PIPE CUTTERS. Design. Blade

SAWS, PIPE CUTTERS. Design. Blade SAWS, PIPE CUTTERS Design With the handy pistol shape, already laid pipes can be quickly and easily shortened. Pumping movements release the ratchet mechanism and the blade is thus pushed through the cutting

More information

Techline Flat Cross Splice. Techline Yoke Clamps* Techline Gang Clamps* TECHLINE. *Yoke Clamps Are Available To Fit Any Width.

Techline Flat Cross Splice. Techline Yoke Clamps* Techline Gang Clamps* TECHLINE. *Yoke Clamps Are Available To Fit Any Width. Techline Flat Cross Splice SIZE HD GALVANIZED ALUMINUM 304 SS 2Ó TLXS-2 HDG TLXS-2 AL TLXS-2 SS 3Ó TLXS-3 HDG TLXS-3 AL TLXS-3-SS 4Ó TLXS-4 HDG TLXS-4 AL TLXS-4 SS 6Ó TLXS-6-HDG TLXS-6 AL TLXS-6 SS TECHLINE

More information

Geberit Duofix. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio

Geberit Duofix. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio Geberit Duofix Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio Masse Geberit Duofix Element für Wand-WC, cm, mit Sigma Unterputzspülkasten cm 9¾" (500) 4¾" (0)

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 04/15/2016 Issued: 06/24/2014 Visit www.ati-es.com for current Revised: 09/24/2014 Page 1 of 21 Maine

More information

SECTION FINISH HARDWARE

SECTION FINISH HARDWARE SECTION 08710 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Finish Hardware as shown and detailed on the Drawings

More information

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS www.jayline.co.nz www.fisherstoves.co.nz 150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS WARNING: This flue kit has been manufactured in accordance with as/nzs 2918:2001 and tested to

More information

Installation Instructions

Installation Instructions For Medium (15-18.5K) + Heavy duty (-8.5K) Air Conditioner READ BEFORE INSTALLING UNIT To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges

More information

Dual Lock Reclosable Fasteners - Piece Parts

Dual Lock Reclosable Fasteners - Piece Parts Dual Lock Reclosable Fasteners - Piece Parts Technical Data Sheet April 2015 General Description 3M Dual Lock Reclosable Fasteners are positive-locking, blind fasteners designed for attaching automotive

More information

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR C1 Table of Contents 1, 15 51, 515 feature a neck mounted rotatable core with either a round or square neck. Aluminum or steel perforated face is, 5 R, supply, ceiling diffusers feature neck mounted curved

More information

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS SECTION 15062 NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS For best results, display hidden notes to specifier. PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe supports. B. Conduit supports. C. Duct supports,

More information

Castle Frame Assembly Table AT-8. Diagnostics Manual. Castle, Inc. Petaluma, CA

Castle Frame Assembly Table AT-8. Diagnostics Manual. Castle, Inc. Petaluma, CA Castle Frame Assembly Table AT-8 Diagnostics Manual Castle, Inc. Petaluma, CA 800-282-8338 Solutions Index Adjusting the Tabletop.. 8.01 Adjusting the Fence... 8.02 Aligning the Arm... 8.10 Adjusting Bracket..

More information

HLC-1000 High-limit Humidity Control

HLC-1000 High-limit Humidity Control FANs 216, 1628.3 Product/Technical Bulletin HLC-1000 Issue Date 1197 HLC-1000 High-limit Humidity Control The HLC-1000 is designed to limit duct humidity by comparing a controller s request for humidification

More information

1.04 QUALITY ASSURANCE

1.04 QUALITY ASSURANCE SECTION 07312 ARCHITECTURAL ASPHALT SHINGLES PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Airfoil Blade Return Air Models 71FH, 7145H 45 Deflection, 3/4" (19) Blade Spacing The airfoil blades are fixed at a 45 angle. This grille is vision proof when installed in a low or high sidewall location

More information

LINEAR GRILLES AND REGISTERS

LINEAR GRILLES AND REGISTERS LINEAR GRILLES AND REGISTERS Linear Grille ( Continuous type ) Linear Grille ( Flange type ) Linear Curved Grille INTRODUCTION COSMOS Linear Grilles and Registers covers a wide range for supply and return

More information

675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure

675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure INSTALLATION INSTRUCTIONS 675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure Call Technical Dept @ 1-800-452-2726 QCI1003 Page 1 of 9 Certified 10/01/09 INSTALLATION NOTES: Unpack your unit carefully

More information

Joint Preparation prior to Tensioning: General:

Joint Preparation prior to Tensioning: General: `Hydraulic Tensioner Procedure for 50% tensioning: Document: PWL-HTS-101 Joint Preparation prior to Tensioning: General: Clean Flanges and check for scars on the flange surface area Check studs and nuts

More information

ELEVEN COLLABORATIVE. CONFERENCE TOPS Assembly Instructions

ELEVEN COLLABORATIVE. CONFERENCE TOPS Assembly Instructions ELEVEN COLLABORATIVE Table of Contents SUPPORT BRACE ASSEMBLY.... 3 TABLE BASE FRAME ASSEMBLY.... 4 LEG ATTACHMENT.... 5 TOP JOINING PLATE ASSEMBLY... 6 TOP CLAMP/TOP SPACER INSTALLATION.... 7 TOP PLACEMENT

More information

Oil-Water Separator Design Checklist

Oil-Water Separator Design Checklist CHECKLIST C3 Revised 5/2/2016 Oil-Water Separator Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private oil-water

More information

SERIES 360. Single Hung Windows. NOTE: Read instructions completely before attempting any installation.

SERIES 360. Single Hung Windows. NOTE: Read instructions completely before attempting any installation. Installation Instructions SERIES 360 Single Hung Windows Page 2: Opening Preparation and Wood Buck Installation and Figure 1 Page 3-5: Installation Instructions for Series 360 WINDOWS Page 6: Figure 2:

More information

Method of Build 1. General

Method of Build 1. General Method of Build 1 General GLAZED ELEVATIONS Viso Double Glazed in glazed form differs from many other systems as the vertical joints can have Viso dry joints or the unique HIDDEN mullion post between glazed

More information

INSTRUCTIONS AND REPAIR PARTS LIST

INSTRUCTIONS AND REPAIR PARTS LIST INSTRUCTIONS AND REPAIR PARTS LIST Model No. F60MB F60MB+20 Description and approximate capacities 2 Shells, 64 bushel, 1.6 Tons (54.5 kg) 3 Shells, 84 bushel, 2.1 Tons (1909.1 kg) F60MB, F60MB+20 MBSLGT,

More information

SECTION ASPHALT SHINGLES

SECTION ASPHALT SHINGLES SECTION 07311 ASPHALT SHINGLES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Asphalt shingle roofing. 2. Flexible sheet membranes for eave protection, underlayment, and valley protection. 3. Associated

More information

Heat Exchanger Construction Checklist

Heat Exchanger Construction Checklist Heat Exchanger Checklist Project: Pump tag: Building: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing. The checklist

More information

MODELS 49 RA 49 RAZ 49 RAC

MODELS 49 RA 49 RAZ 49 RAC General Safety and Maintenance Manual MODEL grinder featuring a rear exhaust. Model Number Exhaust Direction REAR Throttle Type (L) Lever or (K) Safety Lever Speed 12000 to 14000 R.P.M (13500rpm is standard)

More information

Precision Chucks for Improved Accuracy and Increased Productivity

Precision Chucks for Improved Accuracy and Increased Productivity Precision Workholding Technology Precision Chucks for Improved Accuracy and Increased Productivity Precision Air Chucks (Self Contained Design) MicroCentric Precision Air Chucks feature a patented open

More information

Standard Specifications

Standard Specifications Standard Specifications PART 1.00 GENERAL 1.01 DECRIPTION SECTION 02620 PRECAST REINFORCED CONCRETE SANITARY MANHOLES A. Work included: The Contractor shall furnish all labor, materials, equipment, and

More information

variety of cuts including chamfers, O-Ring grooves, lens rings and other angular surfaces.

variety of cuts including chamfers, O-Ring grooves, lens rings and other angular surfaces. FF6300 FLANGE FACER 6 2015 FF63 Performance. Versatility. Safety. The rigid and versatile FF6300 delivers high-torque performance to quickly re-face flanges and repair sealing and bearing surfaces efficiently

More information

FIELD LOK 350. Gasket 4" 24" JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61

FIELD LOK 350. Gasket 4 24 JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61 4" 24" FIELD LOK 350 JOINT RESTRAINT Gasket FOR WATER & WASTEWATER, FIRE ROTECTION & INDUSTRIAL ALICATIONS 4" 24" FIELD LOK 350 Gasket 2 Table of Contents FIELD LOK 350 Gasket 3 Assembly 4 Alternative

More information

Assembly Instructions

Assembly Instructions InTandem Table System November 20 InTandem Table System - Worksurface #4 x/" 4 wood screw power beam Tools Provided T-0 Extended Torx Driver T-25 Torx Driver Additional Tools Required Soft protective

More information

Extrusions POLYLOCK ATTACHING EXTRUSIONS

Extrusions POLYLOCK ATTACHING EXTRUSIONS Extrusions POLYLOCK ATTACHING EXTRUSIONS ITEM # DESCRIPTION USES 1001 Aluminum Girt 16 lengths Used in metal end packages and sidewalls as horizontal members. Requires girt/baseboard splice (#1000). 1000

More information

Kinetic Reflex T -Stripper Wire Stripper

Kinetic Reflex T -Stripper Wire Stripper Invented and manufactured at our Sycamore, Illinois facility, the T -Stripper line is the leading brand name in the world. Kinetic Reflex T -Stripper Ergonomic handles with Santoprene thermoplastic grip

More information

GRAND PIANO HARDWARE AND ACCESSORIES

GRAND PIANO HARDWARE AND ACCESSORIES GRAND PIANO HARDWARE AND ACCESSORIES LID SUPPORT CUP No. 938 - Solid brass. Each No. 938N - Nickel plated. Each GRAND RAIL PROP NUTS Slotted grand rail prop nuts for replacement. Solid Brass. No. 925 -

More information

UPM 6X. UPM 6X Standard stock Tee socket sized for 5" schedule 40 or 80 Pipe. Page 1 of 8

UPM 6X. UPM 6X Standard stock Tee socket sized for 5 schedule 40 or 80 Pipe. Page 1 of 8 Page 1 of 8 UPM 6X A. TEE SOCKET: 6 O.D. PIPE SOCKET TO FIT OVER 5 SCHEDULE 40 OR 80 STEEL PIPE B. CROSS PIECE: 2 X 2 X 1/8, LENGTH DEPENDENT ON MODULE USED, SQ. TUBE 2 PLACES C. LONGITUDINAL: 2 X 2 X

More information

EuroMag Series PCB Mount Terminal Blocks. EM3123 Series Euro-Mag Terminal Blocks 3.50 Centers; Modular. Part Numbering System

EuroMag Series PCB Mount Terminal Blocks. EM3123 Series Euro-Mag Terminal Blocks 3.50 Centers; Modular. Part Numbering System EuroMag PCB Mount Terminal Blocks EM.0 Centers; Modular Rating: A, 00V Center Spacing: 0. (.0mm) Wire Range: #1- AWG Housing Material: Black Polyamide Type /, V0 Screw Size: M.0 Chromate Steel Operating

More information

MEETS ADA REQUIREMENTS!

MEETS ADA REQUIREMENTS! PUSH / PULL LATCH HL-6 MEETS ADA REQUIREMENTS! HL-6/EO EXIT ONLY LATCH HL-6/EO Exit Only Latch for applications where only one side of door is used for exit or entry. Ideal for situations where the security

More information

10 ZX FACING / CONTOURING HEADS 16 ZX MODULAR BORING TOOLS (MBT) 22 ZX VALVE SEAT POCKET TOOLS 31 SPECIAL APPLICATIONS 35 HOW TO REQUEST A QUOTATION

10 ZX FACING / CONTOURING HEADS 16 ZX MODULAR BORING TOOLS (MBT) 22 ZX VALVE SEAT POCKET TOOLS 31 SPECIAL APPLICATIONS 35 HOW TO REQUEST A QUOTATION ZX Systems TM FACING, & CONTOURING ZXBORING, SYSTEMS contents 2 OVERVIEW OF ZX BORING, FACING, AND CONTOURING SYSTEMS 10 ZX FACING / CONTOURING HEADS 16 ZX MODULAR BORING TOOLS (MBT) 22 ZX VALVE SEAT POCKET

More information

Installation Instructions for. Handrail Component System

Installation Instructions for. Handrail Component System Handrail STEP-BY-STEP Installation Instructions for Handrail Component System Rise in Inches Run in Inches 8 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13 13.5 14 14.5 15 8.5 47 45 43 42 40 39 38 36 35 34 33 32

More information