GENERAL ISOMETRIC LAYOUT
|
|
- Bernard Gilmore
- 6 years ago
- Views:
Transcription
1 EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE GATE LID CARBATHAN HG 0 WEB GRAY LOWER PAN GRATING ALUMINUM WIPER WALL CARBATHANE HG, 90 GRAY STRUCTURAL SPECIFICATIONS:. FLOODGATE MATERIAL TO BE ALUMINUM AS FOLLOWS: LID - " x /" x /" ALUM EXTRUSIONS - GRADE 00-T MIN. Fᵧ= KSI LID AND PAN - " x " x /" ALUM TUBING - GRADE 0 MIN. Fᵧ=0 KSI PAN - /" SMOOTH ALUM PLATE - GRADE 0 MIN. Fᵧ=0 KSI ALUM FLAT BARS, STRUCTURAL ANGLES, HINGES GRADE 0-T MIN. Fᵧ=0 KSI ALUM CHANNELS - " x " x /" VERTICAL & " x " x /" HORIZONTAL.. HINGE BOLTS, PINS, AND MACHINE SCREWS TO BE STAINLESS STEEL - GRADE 0, MIN. Fᵧ=90 KSI.. RETENTION ARM ANCHOR BOLTS SHALL BE STAINLESS STEEL STANDARD THREAD BOLTS SET IN VINYLESTER BASED ADHESIVE CONTAINED IN A GLASS CAPSULE, INSTALLED PER SIMPSON STRONG TIE SPECIFICATIONS.. ALUMINUM TO BE WELDED WITH ALUMINUM WIRE - PER 0 AWS A.0 /.. GROUT TO BE COMMERCIAL GRADE NON-SHRINKING GROUT.. ALL WELDS REQUIRED FOR STRUCTURAL STRENGTH OF THE LID OR PAN ARE CALLED OUT ON THESE DRAWINGS. ALL OTHER WELDING, NOT SHOWN OR CALLED OUT ON THESE DRAWINGS, ARE ESSENTIALLY NON-STRUCTURAL WELDS OR WELDS WITH NEGLIGIBLE LOADS AND RESULTING STRESSES. EXAMPLES OF SUCH WELDS ARE AT SEAMS, SIDES, PAN TROUGH, AND LID TRIM ANGLES. THESE WELDS ARE TO BE SIZED BY THE FABRICATOR, TAKING INTO CONSIDERATION ASSEMBLY, TRANSPORT LIFT AND CONTINUITY REQUIREMENTS. THEY MUST BE BY FLOODBREAK.. ALL CONCRETE FOUNDATION POURS AND THEIR TIE-DOWNS TO EXISTING FOUNDATIONS SHOWN IN THESE DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY. DESIGN OF THE CONCRETE FOUNDATION SLABS IS BY OTHERS. DESIGN AND SUPERVISION OF INSTALLATION OF RETENTION ARMS, ANCHOR BOLTS, AND GATE ANCHORS ARE BY FLOODBREAK. ALL CONCRETE TO BE 000 PSI MINIMUM DAY STRENGTH. REINFORCED IN EACH DIRECTION WITH ASTM - A MIN. Fᵧ=0 KSI. SPECIAL ATTENTION SHALL BE PAID TO PROPER SUPPORT OF RETENTION ARM ANCHOR BOLTS INTO THE SUPPORTING CONCRETE.. ALL GASKET MATERIAL TO BE EPDM RUBBER. 9. ALL DIMENSIONS ARE IN FEET AND INCHES. " DRAIN FLOOD SIDE TYPICAL NOTE: LAYOUT, SIZES AND DETAIL ARE GATE-SPECIFIC. THIS VIEW SHOWN IS SECTIONED IN HALF. ( :) GENERAL ISOMETRIC LAYOUT PASS //0 SHEET OF 9
2 FROM END TO END OF PAN ANGLES 0'-0" INSIDE WIPER WALL WET SIDE '- " '- " 9 0 " EDGE OF PAN ANGLE TO C/L OF " DRAIN TYP LID AND PAN LAYOUT :0 DRY SIDE 9 TYPICAL "x"x/ LID STIFFENER TUBE TYPICAL "x"x/ PAN STIFFENER TUBE TYPICAL GRATING TYPICAL PAN ANCHOR PLATE TYPICAL LID ANCHOR PLATE AND RETENTION ARMS TYPICAL HINGE DETAIL TYPICAL PAN SPLICE DETAIL TYPICAL " VERTICAL AND " HORIZONTAL INSTALL BRACKETS "x" CONTINUOUS DRAIN TROUGH SHEET OF 9 PASS //0
3 EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE 0'-" (FIELD VERIFY) 0'-0" FROM INSIDE TO INSIDE OF WIPER WALLS " 0'-0" SECTION 0'-0" SECTION " '-" '- " FROM EDGE OF PAN ANGLE TO OF DRAIN GENERAL FORMULA FOR SET-DOWN: GATE HEIGHT + " " = WIDTH GATE LENGTH + " = LENGTH " TOPPING SLAB = DEPTH 0'-0" INSIDE OF WIPER WALL TO C/L OF " DRAIN LID AND PAN INSTALLATION VIEW (WITH CONCRETE SET-DOWN) : SHEET OF 9 PASS //0
4 TYPICAL CROSS-SECTION OF GATE ASSEMBLY '-0" GATE HEIGHT D " '-0" '- " PROPOSED OR EXISTING WIPER WALL SUPPORT STRUCTURE (BY OTHERS) "x"x/" LID STIFFENER TUBE RETENTION ARM ANCHOR PLATE RETENTION ARMS: /"x/" FLAT STOCK, ONE UPPER, TWO LOWER. /"x/" SLOT W/ /" STAINLESS STEEL PIN TYPICAL GRATING "x /"x/" EXTRUDED RIBBED PANELS TYPICAL /" LEVELING BOLTS 9 TYPICAL " DRAIN INSTALLED IN "x" CONTINUOUS DRAIN TROUGH 0 TYPICAL /" STAINLESS STEEL ANCHOR BOLTS SET IN EPOXY AND ANCHORED INTO CONCRETE STRUCTURAL SLAB AS SHOWN TYPICAL /" STAINLESS STEEL INSTALLATION BOLTS ANCHORED INTO CONCRETE STRUCTURAL SLAB EXISTING SURFACE " MINIMUM TOPPING SLAB ENVELOPES PAN AND BRINGS IT UP TO GRADE (FIELD VERIFY SET-DOWN) " MINIMUM CONCRETE STRUCTURAL SLAB (BY OTHERS) " FROM TOP OF PAN TO TOP OF ANGLE 9 0 " '- " '-9 " '-" SHEET OF 9 PASS //0
5 " " '-0" '- " '- " " " " " TYPICAL "x"x/" ANGLE TYPICAL "x"x/ PAN STIFFENER TUBE "x" CONTINUOUS DRAIN TROUGH TYPICAL GRATING PAN "x"x/" VERTICAL CHANNEL INSTALL BRACKET "x"x/" HORIZONTAL CHANNEL INSTALL BRACKET TYPICAL "x"x/ LID STIFFENER TUBE LID AND PAN SECTION " " 9" " " " '-" " PAN SECTION " " " " " " LID SECTION PASS //0 SHEET OF 9
6 " TOLERANCE AT WALL GROUT SOLID FROM TOP TO BOTTOM OF WIPER WALLS (TYPICAL FOR EACH SIDE) " D D " THK ALUMINUM WIPER WALL " " " " TYP /" UNC STAINLESS STEEL MACHINE SCREWS VERTICAL ROWS, SIX EACH ROW, TOTAL MACHINE SCREWS EACH WALL. SLOTTED FOR /"Ø PIN HINGE SECTION D-D : " HOLE FOR /"Ø PIN " " " " " " TYP PAN SPLICE JOINT DETAIL NOTE: "x"x/" ALUMINUM ANGLE BACK-TO-BACK BOLTED AT " 0.C. & WELDED TO PAN FLOOR 0 " " " "x"x/" VERTICAL INSTALL CHANNEL "x"x/" HORIZONTAL INSTALL CHANNEL TYPICAL "x"x/" PAN STIFFENER TUBE TYPICAL "x"x/" ANGLE " " " TYP WIPER WALL FRONT SECTION " " " TYP PAN COMPONENT ASSY PASS //0 SHEET OF 9
7 0'-0" INSIDE WIPER WALL TO CENTER '-" '-0" '-0" '-" '-" '-" '-" '-" " " 0 '-" '- " '- " '- " '- " '- " '- " LID AND PAN COMPONENT LAYOUT (NOTE: THIS VIEW IS SECTIONED IN HALF. ALL DIMS SYMMETRICAL FROM EDGE OF WIPER WALLS) 9 0 WIPER WALL PRESSURE PLATE PAN ANCHOR PLATE LID W/ TYP "x /"x/" EXTRUDED PANELS TYP "x"x/" PAN STIFFENER LID ANCHOR PLATE TYP "x"x/" LID STIFFENER TYP " VERTICAL AND " HORIZONTAL INSTALL BRACKETS TYP RETENTION ARMS " DRAIN INSTALLED TO "x" DRAIN TROUGH SHEET OF 9 PASS //0
8 /" x /" GASKET FLANGE " " /" RUBBER GASKET " " " "x"x/" ANGLE SEE VIEW BELOW FOR WELD NOTES " " " " " " /" GASKET FLANGE /" SPLICE PLATE TYPICAL LID AT SPLICE "x"x/" ANGLE /" GASKET HINGE DETAIL CLOSED "x /"x/" EXTRUDED RIBBED PANELS /" GASKET /" GASKET FLANGE "x"x/" PAN TUBING TYPICAL LID AT WIPER WALL DETAIL D HINGE OPEN SHEET OF 9 PASS //0
9 E E SECTION E-E : TYPICAL LID ANCHOR YOKE PLATE DETAIL TYPICAL PAN ANCHOR PLATE DETAIL SHEET 9 OF 9 PASS //0
Midwest Roadside Safety Facility
19'-11 1/2" 6083 239'-11 1/2" 73139 Impact 1100C 25 43 5/16" 1100 upstream from the upstream face of the first shear fender downstream of the joint between barrier nos. 7 and 8 Upstream End Downstream
More informationAUXILIARY FRAMING AND ACCESSORIES
CUSTOM CABINETS & RACKS STRUT AND ACCESSO- RIES JUNCTION KITS ANGLE AND BRACE KITS SPLICE KITS BRACE KITS INSTALLATION KITS WALL ANGLE KITS RUBBER END CAPS SUPPORT INSTALLATION AND SUPPORT KITS STANCHION
More informationMANHOLES PART I: GENERAL. A. Precast Concrete Manholes
MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a
More informationKOLO SHELTER Installation Instructions Parts List
Parts List Roof Cap Rafter Upright Polycarbonate Polycarbonate Drop Polycarbonate Flange Center Weldment (Short length shown above) Polycarbonate Edge Bolt.25 x 6.5 Bolt.625 x 7.5 Threaded Rod.75 x 14
More informationMidwest Roadside Safety Facility
28 Spaces @ 75"=2100" 100' 3:1 Cut 40' 75" (TYP.) 3:1 Soil Cut 3:1 1 2 3 4 5 6 7 8 9 10 25 12 13 11 14 15 16 17 18 19 20 21 22 23 24 25 26 75" 300" or Two 12'-6" Section End Section 300" or Two 12'-6"
More informationMidwest Roadside Safety Facility
28 Spaces @ 75"=175'-0" 100'-0" 3:1 Cut 40'-0" 6'-3" (TYP.) 3:1 Soil Cut 3:1 1 2 3 4 5 6 7 8 9 10 25 12 13 11 14 15 16 17 18 19 20 21 22 23 24 25 26 6'-3" 25'-0" or Two Section 12-gauge End Section 25'-0"
More informationMidwest Roadside Safety Facility
28 Spaces @ 75"=175'-0" 6'-3" (TYP.) 8'-0" Soil Cut 1 2 3 4 5 6 7 8 9 10 12 13 11 14 15 16 17 18 19 20 21 22 23 24 25 25 C.I.P. 26 6'-3" 25'-0" or Two Section End Section 25'-0" or Two Section End Section
More informationALUMINUM PIPE GUIDERAIL 01/01/
NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy
More informationMEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C
MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of
More informationKO LO SH E LT E R. High Capacity and Flexibility
KO LO SH E LT E R High Capacity and Flexibility The unique styling of our redesigned Dero Kolo Shelter will help beautify your facility and provide secure, covered bike parking for cyclists. The Kolo is
More information10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS
10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS 10x12 WOOD SKID FLOOR FLOOR SYSTEM FOR 10x12 TRICO AND FLORA SHEDS RAW MATERIALS LIST: 2 (9) FLOOR FRAMING AND SHEATHING: 1) BAND BOARD 2 x 6 x 12 PRESSURE
More informationSutton Screened in Awning / Porch
Sutton Screened in Awning / Porch Sections: Project Overview Roof Work Cedar Framing Canopy Frame Screen Frames Misc. Sheet 1 - - - Index Sheet 2 - - - Project Summary Sheet 3 - - - Roof Work overview
More informationSECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Benches. B. Trash receptacles. C. Bike storage. 1.2 REFERENCE STANDARDS A. Including but not limited to: 1. American Society for Testing and Materials (ASTM). 1.3
More informationRAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch
Limits of pay length for Bridge RailType 10M (For post spacing, see Dwg. No. B ) B60610 (Use with B60610A) 8 min. 1 max. 8 min. 1 max. 10 0 Max. 10 0 Max. post spacing 10 0 Max. 2 5 Post 1 x 1 slotted
More informationSTEEL PIPE GUIDERAIL 01/01/
NOTES PIPE RAILING & POSTS: Pipe Rails and s shall be in accordance with ASTM A5 Grade B for standard weight pipe and ASTM A500 Grade B, C or D or ASTM A50 for structural tube. Bars for handrail supports
More informationBol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:
Bol 8' 24' Round Tapered and Straight Wood Poles FIXTURE TYPE: PROJECT NAME: Round Taper Glulam solid wood and aluminum pole available in 8' 24' lengths. Tenon adapters, slip fitters and side bracket mounts
More informationSECTION THERAPEUTIC POOL ACCESSORIES
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 13 17 23.11 THERAPEUTIC POOL ACCESSORIES SPEC WRITER NOTES: Delete between // // if not applicable to project. Also, delete any other item or paragraph not applicable
More informationCROSSBAR RAFTER ISOMETRIC
Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are
More informationLook Our New Technology
1. PRECAST WALL CONNECTORS Tunel Pey Khazar PSK Wall Nail are precast wall connectors designed for tension splicing. The structural connection between precast wall and other concrete element is achieved
More informationSTRATUS SHELTER. Take bike parking to new heights
Take bike parking to new heights The Stratus Shelter is a striking bike shelter option for any transit station, university campus, or multi-family residential building project. It is constructed of American
More informationSERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS
Table of Contents I. Care and Maintenance... 2 II. Tools / Materials, Sealant Requirements, & Anchor Instructions... 2 III. Structure Verification & Sub-Sillpan Installation... 3 1. Opening Verification...3
More informationDouble Beam Freestanding Pergola Installation Guide
Double Beam Freestanding Pergola Installation Guide Patent Pending. Copyright 2011 USAVinyl, LLC - All Rights Reserved The information contained in these instructions are proprietary to USAVinyl, LLC and
More informationMidwest Roadside Safety Facility
C 1690" A 42926 75" 1905 150" 3810 G E F F 11 10 9 8 7 6 5 4 3 2 C D D 25 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 21.2 G E Impact 2270P 17 Spaces @ 75" [1905] Spacing = 106' 3" [32385] 1 1662 1/2"
More informationSturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models
Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Project Number ME086-05 by Brent Leatherman, P.E. Timber Tech Engineering, Inc E-Mail: bl@timbertecheng.com January
More informationMidwest Roadside Safety Facility
2 Spaces @ 75" [05]= 150" 3810 4 Spaces @ 3 Spaces @ 4 Spaces @ 18.75" 37.5" [953]= 37.5" [953]= [476] 112 1/2" 150" = 75" 2857 3810 [05] 18 476 7 Spaces @ 75" [05]=525" [13335] 21 20 18 17 1615 14 1312
More informationNX7 SERIES 5-1/2 HANDRAIL
STORAGE & HANDLING The handrails are shipped unassembled. Upon receipt, immediately check all material for any damage that may have occurred in transit and verify that all of the items and quantities are
More informationSPECIFICATION SHEETS. POLARIS FRAMELESS GLASS pool fencing
SPECIFICATION SHEETS POLARIS FRAMELESS GLASS pool fencing 8-10mm 5mm 1254mm 1200mm 12MM 1200MM HIGH STANDARD PANEL * GLASS POOL FENCING MAXIMUM SPAN 1600MM 12MM 1200MM HIGH GATE PANEL 12MM 1200MM HIGH
More informationTYPE J (20 FT - 40 FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" NOTE: sheet 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.
Column truss connection Chord splice (see details (See details sheets 3 & 4 of 10) s Top truss chord Free end panel 10-0" Support end panels length varies (See chart below) \ Truss Back truss chord Top
More informationATI Evaluation Service A Division of Architectural Testing Certification Services
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 10/13/2016 Issued: 12/17/2014 Visit www.ati-es.com for current status Revised: 06/05/2015 Page 1 of
More information1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards. B. See Division 5 Section "Pipe and Tube Railings"
More informationSECTION METAL FABRICATIONS
SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM
More informationEMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL
EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION 05720 METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL EMMEGI ARCHITECTURAL FENCING is a high quality steel fencing system comprised of a hybrid
More informationPERFORM WITH PRECISION MAGNETIC PRODUCTS FOR PRECASTING CONCRETE CONSTRUCTION SOLUTIONS BROCHURE
MAGNETIC PRODUCTS FOR PRECASTING PERFORM WITH PRECISION CONCRETE CONSTRUCTION SOLUTIONS BROCHURE Form Magnets ON/OFF MAGNETS Strong adhesion and shear capacity -650# to 2500# adhesion Easy to turn on or
More information24" B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3 " X501 Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOT
B B Joint Joint See MARKINGS Note PCB-RXX-350-TL3 " Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOTES GENERAL: This barrier may be manufactured with reinforcing steel
More informationOxford Stalls Installation Instructions
Oxford Stalls Installation Instructions RAMM Horse Fencing and Stalls 13150 Airport Hwy. Swanton, OH 43558-9615 1-800-434-8456 Rev. 8/15/17 Before You Start Typical stall sizes are 10 x 10, 12 x 12 or
More informationFlat Panel Stand FPZ-655. for 32" to 55" Flat Panel Screens FEATURES. Reinforced universal adapter plate for a strong hold
FPZ-655 Flat Panel Stand for 32" to 55" Flat Panel Screens For a viewing experience that really stands out, Peerless FPZ-655 Universal Flat Panel Stand for 32" 55" flat panel TVs provides a brilliant combination
More information2013 Feeney (2/14) # B. Aluminum Railing Systems
2013 Feeney (2/14) #2012-425B Aluminum Railing Systems Aluminum Railing Systems Searching For a Complete Railing System? Look No Further. DesignRail by feeney aluminum railing frame systems combine the
More information2015 Feeney (8/15) # D. Aluminum Railing Systems
2015 Feeney (8/15) #2012-425D Aluminum Railing Systems Aluminum Railing Systems Searching For a Complete Railing System? Look No Further. DesignRail by feeney aluminum railing frame systems combine the
More informationResidential & Industrial Fence
Residential & Industrial Fence Assembly Instructions CONTENTS 02: OVERVIEW & CONTENTS 03: PRODUCT SPECIFICATIONS 04: GETTING STARTED 05: WALL ATTACHMENT & LINE POST ASSEMBLY 06: CORNER POST ASSEMBLY 07:
More informationLeveling Feet, Base Plates and Casters
Leveling Feet, Base Plates and Casters 77 Leveling Foot 1 1 Fastening to profile end Fastening in T-slot of profile For leveling tables and light equipment. Ratchet-type height adjustment requires no tools.
More informationSPECIFICATION SHEETS. FRAMELESS GLASS pool fencing
SPECIFICATION SHEETS FRAMELESS GLASS pool fencing 8-10mm 12mm STANDARDS & NATA TESTING 1254mm 1200mm * GLASS POOL FENCING MAXIMUM SPAN 2000MM 12MM TOUGHENED SAFETY GLASS 1200MM HIGH FULLY AS/NZ-2208 CERTIFIED
More informationSECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 07720 ROOF ACCESSORIES PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Attachment clamp system for standing seam metal roofs. B. Attachment
More information(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.
Column truss connection (See details sheets 3 & 4 of 10) \ Span (Odd number of panels) \ Span (Even number of panels) Back truss chord Top truss chord \ Truss Chord splice Truss depth (See details \ Left
More informationSPECIFICATION SHEETS. POLARIS FRAMELESS GLASS pool fencing
SPECIFICATION SHEETS POLARIS FRAMELESS GLASS pool fencing 8-mm 5mm AS2208 Heat Soaked & Toughened Glass 1254mm 1200mm 12MM 1200MM HIGH STANDARD PANEL * GLASS POOL FENCING MAXIMUM SPAN 1600MM 12MM 1200MM
More information1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.
SECTION 12360 LIBRARY SHELVING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 06100 - Carpentry. 2. 09200 - Metal Studs, Lath, Suspension Ceiling, Plaster and Stucco. 3. 09660 - Resilient Tile Flooring.
More informationInstallation Instructions
Column & Beam Units with Debris Netting Installation Instructions Laminated Wood Systems, Inc. Seward, Nebraska 800-949-3526 2015 LWS, INC. AVR-NET INSTALL 05-12-16 AVR Installation Notes 1 Safety The
More informationALUMINUM RAILING INSTALLATION INSTRUCTIONS. 1) Check Contents Of Packages: Verify that all parts have arrived and that they match the packing list.
ALUMINUM RAILING INSTALLATION INSTRUCTIONS AF#2010-308D Glass Infill Systems 1) Check Contents Of Packages: Verify that all parts have arrived and that they match the packing list. 2) Gather and Identify
More informationInstallation Instructions for Solar Snow Pad (SSP-T-3)
Installation Instructions for Solar Snow Pad (SSP-T-3) Warning- Do not use this product on solar arrays where the calculated array snow loads exceed 50 pounds per square foot (psf). Most solar panels are
More informationUtility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles
Utility Structures Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles PRODUCT GUIDE & TECHNICAL REFERENCE MANUAL Providing the right solutions. UTILITY STRUCTURES Perfect
More informationEquilibrium. Conference Table. Installation Instruction. Revision B 11/07/16
Equilibrium Conference Table Installation Instruction Revision B 11/07/16 Equilibrium End User Agreement Enwork Equilibrium table bases must be installed directly onto a four inch minimum thickness concrete
More informationSECTION PRECAST CONCRETE SECTIONAL MANHOLES
SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,
More informationBuildingEnvelope Oldcastle ( ) -
BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com RELIANCE -LT CURTAIN WALL 2" X 7-1/2" / POLYAMIDE PRESSURE PLATE / 1" GLAZING Elev-Reliance-LT-750-PolyPP H0042-Steel-Anchor H5021-ShrBlk-Anchors
More informationInstallation Instructions
Important 1. Acclimate materials 24 hrs before installation. Maintain temperature controlled environment after installation 2. Install in accordance with manufacturer s installation instructions. Failure
More informationCSS Central Mount System
CSS-20 Installation Manual CSS-20 Safety Notifications Below are the installation instructions for the CSS-20-2 Long Span Beam Mounting System. Please read these safety notifications prior to beginning
More informationPole Mount Installation Manual
Pole Mount Installation Manual Thank You for Choosing AIMS Power! 1. AIMS Power is a leading supplier of solar products, specializing in PV mounting systems. We ensure our products are manufactured to
More informationSegmental ring types provided by F P McCann: Segments in stock are front bolted. Back bolted segments are available to order: Cross joint Corbel Ring
Building Manual for F P McCann `Smoothbore Shaft Linings with EPDM Gaskets (rev 04) (To be read in conjunction with the Segmental Shaft and Tunnel Safety Data Sheet) Segmental ring types provided by F
More informationVPN: ISBXLR. Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax
VPN: ISBXLR Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JULY 2003 RM649-R2 RM657 RM664 RM861 RM650 RM658-R2 RM665-R2
More informationSquare Straight Steel - 4 Bolt Base Light Poles
Quick Ship Square Bronze over Galvanized Straight Steel Pole - 4 Bolt Base Square Straight Steel - 4 Bolt Base Light Poles Optional Tenon Mounting (specify) "D" Top Diameter Arm Drilling Per Customer Specs.
More informationOXYGEN INSTALLATION. Revision date
12345 1 Hardware List 12345 Flat head wood screw #9 x 7/8 long with #2 Phillips drive, silver Used to attach surfaces and end panels Hex set screw ½-13 x 2 long with 1/4 hex drive, black Used on Legs Hex
More informationTYPICAL STANDOFF GLASS RAIL ELEVATION TYPICAL SECTION RS0B20 WITH RECTANGULAR BACK PLATE TYPICAL STAIRS
Revisions By: CRL SRS STANDOFF RAILING SYSTEM CRL GLASS RAIL S RS0B20 w/ RECTANGULAR BACK PLATE CRL'S GLASS RAIL S CAN BE USED FOR MOUNTING GLASS PANELS UP TO 3/4" (19 MM) IN THICKNESS. THE 4" X 8" (102
More informationSPECIFICATION SHEETS SOFTERCLOS HINGE FOR. FRAMELESS GLASS pool fencing
SPECIFICATION SHEETS SOFTERCLOS HINGE FOR FRAMELESS GLASS pool fencing 8-10mm mm 8 OR 12MM STANDARD GLASS GATE 12MM STANDARD HINGE PANEL AS2208 Heat Soaked & Toughened Glass AS1926.1 Pool Safety Standards
More informationSB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL
SB-WM-ART1-M-BL Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL WARNING The maximum weight of this wall mount is 90 lbs (41 kg). Use with heavier than the maximum
More informationMobile Weapons Storage System Specifications
Mobile Weapons Storage System Specifications Whatever your weapon storage needs, Hi-Density s customized Weapons Storage System will be designed to fit your unique specifications. We recognize that security
More informationRECORD DRAWINGS REVISED TO CONFORM TO CONSTRUCTION RECORDS PROVIDED BY CONTRACTOR GMG BY DATE 11/13 CRS NO.
CELL: (715) 803-8009 MABOSI@WISCONSINPUBLICSERVICE.COM CELL: (715) 573-7806 CHVIRCKS@WISCONSINPUBLICSERVICE.COM CALVIN.KLADE@FTR.COM DGAU@KRONENWETTER.COM SCOTT OLSEN (715) 302-1348 S REVISED TO CONFORM
More informationC. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.
SECTION 105113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationMODEL SJW - HD INSTALLATION INSTRUCTIONS
MODEL SJW - HD INSTALLATION INSTRUCTIONS CONTINUOUS ALUM. WALL FASTENER 12AF CONTINUOUS EXTRUDED ALUM. CONTINUOUS EXTRUDED ALUM. FRAME IMPORTANT INFORMATION WITH SPACER NOTE: REQUIRED WITH SJW-700HD (7"
More informationCOPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX Standard Release A March 2008
COPPER / FIBER MANAGER RACK INSTALLATION INSTRUCTIONS PX101425 Standard Release A March 2008 A UPON RECEIPT OF YOUR Copper / Fiber Manager Rack Great care has been taken to insure that your Copper / Fiber
More informationWaist-high Railing System from Tempered Glass BH-06 ASSEMBLY AND OPERATION MANUAL
Waist-high Railing System from Tempered Glass BH-06 ASSEMBLY AND OPERATION MANUAL Waist-high Railing System from Tempered Glass BH-06 Assembly & Operation Manual Assembly & Operation Manual Dear Customers!
More informationSIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD
Michigan Department of Transportation 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) LUMINAIRE ARM (SEE CONTRACT) POLE CAP 1'-6" (6'-0" ARM) 1'-10" (8'-0" ARM) 2'-0" (10'-0" ARM) NOMINAL RISE 2.38"
More informationSolar. mounting solutions. system components.
Solar mounting solutions system components ABOUT REMOR REMOR Solar is the largest manufacturer of solar mounting systems in Poland. throughout the entire Europe, supplying mountings to over 200 MW of PV
More informationA Shell construction
A Shell construction A 4/2012 Content 1 BASE AND WALL ANCHORING 1.1 Base with mortar bed 1.2 Base with sill plate 1.3 Base with raised sill plate 1.4 Concrete base (mortar bed) 1.5 Concrete base (sill
More information**************************************************************************************************
9300 73 rd Ave N. Brooklyn Park, MN 55428 Free Phone: 800 547 2635 Free Fax: 800 317 8770 Direct Phone: 763 488 9200 Direct Fax: 763 488 9201 e-mail: info@nystrom.com www.nystrom.com PD Series Expansion
More informationDW HORIZONTAL INSTALLATION
AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S
More informationStop Gates & Stop Logs. Series 500. ine. Manufacturing high quality gates since 1977
Stop Gates & Stop Logs Series 500 Manufacturing high quality gates since 1977 ine Stop Gates & Stop Logs Series 500 Contents Stop Gate Introduction 3 Model 501 3 Model 503 4 Model 503-C 4 Stop Gate Specification
More informationNX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP
6-1/4 HANDRAIL W/ VINYL HANDGRIP TYPICAL ASSEMBLY 5 2 BUTT JOINT 12 10 9 1 8 11 6 3 7 4 BUTT JOINT COMPONENT LIST 1 LEFT RETURN 7 UPPER IMPACT ABSORBER 2 RIGHT RETURN 8 LOWER IMPACT ABSORBER 3 OUTSIDE
More informationINSTRUMENT MOUNTING STANDS PRODUCT CATALOG Continuous Tray Support System for Instrumentation and Controls
INSTRUMENT MOUNTING STANDS PRODUCT CATALOG Continuous Tray Support System for Instrumentation and Controls James C. White Company, Inc. Greenville, SC PAGE 5 Standard Instrument Stands SINGLE WALL STAND
More informationB. See Division 05 Section "Pipe and Tube Railings" for metal pipe and tube railings.
SECTION 055000 - METAL FABRICATIONS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following, applicable: 1. Miscellaneous steel framing and supports. 2. Prefabricated building columns. 3. Shelf
More information10 x 10 Flat Top Two Tone Pergola
0 x 0 Flat Top Two Tone Pergola Models: Bordeaux ASSEMBLY GUIDE OPTIONAL ACCESSORIES Arch Kit System ( Arches) Privacy Fence Panel System ( Panels & Middle Post) Bolt Down Bracket Kit ( for Pergola) Ver.0-00
More informationLOCKER SPECIFIERS GUIDE. The standard of excellence for business, industry and institutions. Lockers Cabinets Shelving
LOCKER SPECIFIERS GUIDE Lockers Cabinets Shelving The standard of excellence for business, industry and institutions FINISH GUIDE NANO METAL ROLLER LATCHING SYSTEM For unmatched security, nano metal roller
More informationSIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP
Michigan Department of Transportation 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) LUMINAIRE ARM (SEE CONTRACT) POLE CAP 1'-6" (6'-0" ARM) 1'-10" (8'-0" ARM) 2'-0" (10'-0" ARM) NOMINAL RISE 2.38"
More informationSECTION MANHOLES
SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard
More informationHANDRAIL HEIGHT PER LOCAL CODE AUTHORITY
WITH OPTIONAL S.S. S PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION
More informationGlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)
List of Contents Quantity Description 12 #10 x 1 ½ Flat Head Phillips Screw (see pg. 2) 2 #10 x ½ Pan Head Phillips Screw (see pg. 2) 8 ¼ x 2 ½ Lag Bolt (see pg. 2) 7 ¼ 20 x 5 / 8 Hex Head Bolt (see pg.
More informationNew Product Release: October 2014 Boone Racks
New Product Release: October 2014 Boone Racks Double Fido Fountain Mounting: Surface NOTE: THESE ROUGH-IN DIMENSIONS MAY VARY ½: (13 mm) PLUS OR MINUS NOTE: All dimensions subject to manufacturing variance
More informationSTANDARD 3-PIECE CULTURED MARBLE PANEL INSTALLATION GUIDE
STANDARD -PIECE CULTURED MARBLE PANEL This installation guide applies to all standard -piece panel systems extending to the ceiling where each wall is manufactured in one piece. PH 70.59.55 F 70.59.559
More informationBRIDGE RAILING, 4 TUBE B-26-F POST DETAILS MICHIGAN DEPARTMENT OF TRANSPORTATION
\ ƒ" x 1 " SLOTTED HOLE IN POST AND \ ƒ"! HOLE IN RAIL \ "! x 6" SLOTTED ROUND HEAD BOLTS, WITH 1 PLATE WASHER, 1 LOCK WASHER AND HEX. NUT \ ƒ" x 1 " SLOTTED HOLE IN POST AND \ ƒ"! HOLE IN RAIL \ "! x
More informationConnectors for Cold-Formed Steel Curtain-Wall Construction
The expiration date of this document has been extended until 2/3/3. Introducing Connectors for Cold-Formed Steel Curtain-Wall Construction Code Listed: IAPMO ES ER-238 (800) 999-5099 www.strongtie.com
More informationMH Table of Contents Standard Title/Scope Page Table of Contents SCE Public
MH Table of Contents Standard Title/Scope MH 300 MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Manholes Requirements MH 300.1 Manholes Requirements...........................................
More informationCertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High
CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS Fence Installation Guide 3', 4' & 6' High INSTALLATION GUIDE These instructions are designed to assist both professional installers and do-it-yourselfers
More informationPIVOT DOOR 3400P INSTALLATION INSTRUCTIONS
Table of Contents I. Tools, Sealant Requirements, Anchor Recommended Table...1 II. Opening, Frame & Panel Verification...2-3 III. Frame Assembly...4 IV. Frame Installation...5-7 V. Glazing Instructions...8
More informationCARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)
DETAIL 5 32 5 " 27 32 " 6" OPTIONAL FLAT RECESSED CLOSURE 1 1 4 " 17 32 " 1 25 32 " OPTIONAL BUTTERFLY CLOSURE CARRIER OVERHANG 1'-0" MAX CARRIER SPAN 4'-0" 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER
More informationRodney Hunt. A GA Industries Company Glydaseal Gates
Rodney Hunt A GA Industries Company Glydaseal Gates GUIDE BRONZE GUIDE BAR FRAME NUT POCKET SEAT FACING RESILIENT INVERT SEAT DISC GUIDE BAR ADJUSTMENT BOLT WITH LOCK NUT GUIDE BAR ATTACHING BOLT The Glydaseal
More informationManholes Table of Contents
Standard MH 300 Title Manholes Requirements MH 300.1 Manholes Requirements Manholes Table of Contents Underground Structures Standards MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Precast Tub-Type
More informationThis specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.
SPEC-3500 1/9 1.0 PURPOSE This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. Note: This specification does
More information11 6 Round Building Assembly Instructions
11 6 Round Building Assembly Instructions 11 6 Round Building Hardware List 1. Pro Rib Brite White 36 Wide X 68 Long (Siding Steel) 11 2. Top Wall Wheel Ring 3 3. Base Ring 3 4. 1 ½ X 68 Aluminum Tubes
More informationPrecision Steel Car s 40 Ft. Stock Car
Precision Steel Car s 40 Ft. Stock Car Precision Steel Car Website: www.precisionsteelcar.com E-mail: info@precisionsteelcar.com Revised 12/3/2018 Paul Vernon: (513) 571-5739 PSC 40 ft. Stock Car Kit:
More informationSECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING
SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationInstallation Instructions for Vista Air Vertically Folding Walls
Installation Instructions for Vista Air Vertically Folding Walls Use these instructions in conjunction with your shop drawings to see the specifics that are particular to the model you are installing.
More informationPioneers in Gate Design
Stop Logs Pioneers in Gate Design Hydro Gate 3888 E. 45th Ave. #120 Denver, CO 80216 Your Source for Water Control Gates No matter what type of gates your project demands, chances are excellent Hydro Gate
More informationb. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube
MODEL 240I SECTION 08120 FLUSH ALUMINUM DOORS AND FRAMES PART I GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to deliver and install aluminum doors, frames,
More information