ADDENDUM #01. PROJECT: Saint Mary s University Student Centre Reorganization PROJECT N o : DATE:
|
|
- Anis Dixon
- 5 years ago
- Views:
Transcription
1 ADDENDUM #01 PROJECT: Saint Mary s University Student Centre Reorganization PROJECT N o : DATE: This Addendum shall be considered part of the specifications for the construction of this work and shall be read in conjunction with such specifications. All work mentioned herein shall be in addition to and shall supersede the specifications and shall be included in the contractor s tender. This Addendum shall be read in conjunction with drawings and Specifications ssued for Tender on April This Addendum has a total Twenty-Six (26) pages including attachments. 1. SPECFCATONS 1.1. Reference Specification Section nstructions to Bidders a. Ammend item 1.1 to read as follows: Bids signed, executed and dated will be received before 3:00pm local time as designated by the wall clock at the Facilities Management reception desk, on the 3rd day of May, 2018 at the following address: Saint Mary s University, Facilities Management McNally Building, Room MS Robie Street Halifax, NS B3H 3C Reference Specification Section Door Hardware a. Delete Schlage mortise lockset L9485 x indicator 626, and add Best mortise lock 45H-7-H-15S-626-T-T L/C b. Delete on Duprin electric strike 6216 FS - 630, and add Best electric strike ES5- D-DBM(hand) Reference Specification Section nterior Aluminum Doors and Frames a. Modify item to read: Alumicor FlushGlaze 800 b. Finish to be 0.4mil for Class 2 Clear Anodized c. Clarification: No fire ratings are required. Page 1 of 6
2 1.4. Reference to Section Sliding Aluminum Framed Glass Doors. a. Delete tem 1.5.3: not required for Engineer stamped & signed shop drawings. b. Refer to attached ASK-04 for details and specified hardware and finishes below Reference to Section Aluminum Curtain Wall & SSG Assemblies. a. Back Mullions to suit structural requirements. Engineer accordingly as per specification requirements. b. nterior finish: 0.4mil Clear anodized c. Exterior finish: Duranar paint finish to match existing Reference Specification Section Glass and Glazing a. Add item Glazing Film as follows: i. Glazing Film: 3M Fasara Glass finishes, selection by architect from full line. Provide samples for selection. 2. DRAWNGS 2.1. Reference Architectural Drawing A1.21 Reflected Ceiling Plan Level 3, issued for tender. a. Remove and reinstate portion of the ceiling in corridor where mechanical work is being completed. Refer to mechanical entilation drawings for extent Reference Architectural Sketches ASK-01 to ASK-03, attached a. nstall Exterior Window in conformance with attached details Reference Architectural Sketch ASK-04, Attached a. nstall Sliding Glass Door in accordance with attached details. b. Door to be Alumicor AlumiGlide Series or approved alternated. c. SLDNG GLASS DOOR i. Door Track: 1. Top and Bottom Track: Top track recessed, bottom track surface mounted, extruded aluminum single track profile: To ASTM B221, 6063 alloy with T6 temper. 2. Side Track: Single recess mounted, extruded aluminum track reinforced to take locking hardware: To ASTM B221, 6063 alloy with T6 temper. ii. Frame: Extruded aluminum with joints machined and fabricated to provide neat hairline joints. iii. Frame Finish: 0.4mil for Class 2 Clear Anodized iv. Glazing: 6 mm clear tempered glass. v. Rollers and guides: 1. Rollers: Ball bearing wheels in stainless steel, rail or stile mount as required. 2. Guides: Bronze and stainless steel, rail or stile mount as required 3. Acceptable material: Alumicor standard. Page 2 of 6
3 d. DOOR HARDWARE i. Sliding Door Locks: 1. Hook bolt with two cylinders. 2. Acceptable material: Adams-Rite, MS Exterior cylinder with thumb turn. 4. Egress door hardware: Deadlock cylinder and thumbturn. 5. Acceptable material: Adams-Rite, MS Egress door pivot: Centre hung pivot hinges top and bottom. 7. Strike: Armoured strike. 8. Acceptable material: Adams-Rite, MS Handles: Flush mounted pull handles Refence Architectural Sketches ASK-05 to ASK-07, attached. a. Remove during demolition and reinstate when construction is complete all window coverings as indicated in the attached sketches. b. Supply and install Sun Project Moduline roller shades fully recessed within gypsum bulkhead at locations indicated on above architectural sketches. Supply and install blocking above gypsum bulkhead as required. Roller shade fabric color and opacity to match existing roller shades. Samples of finishes to be submitted to consultants for review Reference Drawing M-3 Level 3 Demolition and New entilation Layout, attached. a. Ad All thermostats shown within the new ventilation layout shall be new thermostats. Remove existing thermostat and extend/modify existing pneumatic tubing as required to suit installation of new thermostat. b. Provide additional transfer ducts as indicated Reference Drawing M-4 Level 4 Demolition and New entilation Layout, attached. a. All thermostats shown within the new ventilation layout shall be new thermostats. Remove existing thermostat and extend/modify existing pneumatic tubing as required to suit installation of new thermostat. b. Provide additional transfer ducts as indicated. c. Extend return ductwork as indicated Reference Drawing M-5 Level 5 Demolition and New entilation Layout, attached. a. All thermostats shown within the new ventilation layout shall be new thermostats. Remove existing thermostat and extend/modify existing pneumatic tubing as required to suit installation of new thermostat. b. Provide additional transfer ducts as indicated Reference Drawing M-6 entilation Details and Schedules, Attached a. All new dual duct boxes shall be complete with pneumatic controls Reference Drawing M-8 Level 4 and 5 New Fire Protection Layout, attached. a. Relocate existing sprinkler heads as indicated. Page 3 of 6
4 2.10. Reference Drawing E-1 Electrical Legend & Luminaire Schedule a. Reference Luminaire Schedule, add the following luminaries to the specified units: Type 4: Philips Cat. No.: 1FGG-30L DS-UN-DM Type 5: Philips Cat. No.: 7705-B-E-A-D E-T Type 6: Philips Cat. No.: EX12-HE-N AC48ST-U-OL1-1 Type 7: Philips Cat. No.: EX12-HE-N-835HO-2-AC48ST-U-OL1-1 Type 8: Philips Cat. No.: LSECO16-BRK ANO-0-10 Type 9: Philips Cat. No.: EX12N-HE-N-835HO-2-AC48ST-U-OL1-1 b. Change "Dual Data Outlet, consisting of a square backbox complete with a single gang tile ring, two category 6 RJ-45 Jacks and faceplate, flush wall mounted..." to "Single Data Outlet, consisting of a square backbox complete with a single gang tile ring, two category 6 RJ-45 Jacks and faceplate, flush wall mounted..." c. Change "3 Data and 1 oice Outlet, consisting of a square backbox complete with a single gang tile ring, four category 6 RJ-45 Jacks and faceplate, flush wall mounted..." to "1 Data and 1 oice Outlet, consisting of a square backbox complete with a single gang tile ring, two category 6 RJ-45 Jacks and faceplate, flush wall mounted..." d. Add a new symbol with the following note "3 Data and 1 oice Outlet, consisting of a square backbox complete with a single gang tile ring, four category 6 RJ-45 Jacks and faceplate, installed in raceway system 18 A.F.F." Reference Drawing E-3 Level 3,4 & 5 Power and Communications Plan a. Add a new Electrical Note "Note 5: Provide and install in wall A outlets as per new detail 10/E5. Coordinate final location of display screen with Architect/Engineer prior to rough-in." b. Change the electrical note 1's on level 5 to Note 5 (per above). c. Add a new Electrical Note "Note 6: Provide and install new dual channel raceway from the accessible ceiling space equal to DS4000 Series Dual Channel" at computer stations near grid line 4. d. Added two symbols at computer stations to identify data requirements. e. Change Connectrac outlets on partial level 4 to raceway outlets (per above) f. dentified location of communication room in the basement (near grid line E3) g. nclude for Ten (10) total new data drops (5 locations x 2 drops) in the ceiling space for future wireless access points throughout the renovation areas (evenly distributed). Final placement to be determined by SMU TSS. h. Supply & nstall a fully functional nurse call system equivalent to Mircom EC-300 to monitor washrooms SC303 & SC306. i. The system to have a 20 LED annunciator, EC dome light above each washroom doors, EC pull cord c/w LED inside each washroom to be located by the toilets. Bottom of cord to be flush with the top of the toilet seat. ii. Main panel to be located in Fred Smither s Centre, coordinate final location on site with SMU representative. iii. Mircom Nurse Call system to be interconnected with DSC NEO security panel by Stanley Security. Page 4 of 6
5 iv. Coordinate above work with Stanley Security. (note: security panel will be programmed to alert SMU-Security of a triggered washroom event) Reference Drawing E-5 Electrical Details a. Add new Detail 10/E5 for Level 5 T system. b. Name change on detail 7/E5 T System w/ Under carpet 3. CLARFCATONS 3.1. Reference Electrical Power and Communications Drawings a. The data room is in the basement of the Student Centre near grid line E3. All voice and data jacks in the building terminate in this room Reference all nterior Design Drawings a. All surfaces inside and outside the millwork along with shelves are to be plastic laminate. No melamine will be accepted Reference Architectural Door schedule a. There is no fire rated glazing in this project. Page 5 of 6
6 4. ATTACHMENTS 4.1. ASK-01 Section Detail Exterior Window Head 4.2. ASK-02 Section Detail Exterior Window Sill 4.3. ASK-03 Plan Detail Exterior Window Jamb 4.4. ASK-04 Section Detail Sliding Glass Door ASK-05 Floor Plan Level 3 Window Blind Locations 4.6. ASK-06 Floor Plan Level 4 Window Blind Locations 4.7. ASK-07 Floor Plan Level 5 Window Blind Locations 4.8. Reference Drawing M-3 Level 3 Demolition and New entilation Layout, issued for Addendum Reference Drawing M-4 Level 4 Demolition and New entilation Layout, issued for Addendum Reference Drawing M-5 Level 5 Demolition and New entilation Layout, issued for Addendum Reference Drawing M-6 entilation Details and Schedules, issued for Addendum Drawing M-8 Level 4 and 5 New Fire Protection Layout, issued for Addendum Drawing E-1 Electrical Legend & Luminaire Schedule, issued for Addendum Drawing E-2 Level 3, 4, & 5 Lighting Plan, issued for Addendum Drawing E-3 Level 3, 4, & 5 Power and Communications Plan, issued for Addendum Drawing E-4 Panel Schedules, issued for Addendum Drawing E-5 Electrical Details, issued for Addendum Drawing E-6 Electrical Specifications, issued for Addendum Drawing E-7 Electrical Specifications, issued for Addendum Drawing ED-1 Level 3, 4, & 5 Demolition Plan, issued for Addendum 01. END OF ADDENDA #01 Page 6 of 6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
1010 Sliding Mall Front
JUNE, 2018 FEATURES 1 Features Screw spline fabrication 1/4" and 1" glazing Permanodic TM anodized finishes in seven standard choices Painted finishes in forty-two standard choices and unlimited custom
More informationRENOVATION TO STUDENT SERVICES/HOUSING FROM HOSPITAL DAKOTA STATE UNIVERSITY MADISON, SOUTH DAKOTA
RENOVATION TO STUDENT SERVICES/HOUSING FROM HOSPITAL DAKOTA STATE UNIVERSITY MADISON, SOUTH DAKOTA KOCH HAZARD ARCHITECTS ADDENDUM DATE:. SCOPE OF THIS ADDENDUM: The following becomes a part of the original
More informationACME 50 Application Guide
ACME 50 Application Guide p1 CONTENTS Features & Benefits... 2 Product Images... 3-8 TRIM AND CONNECTORS Trim & Connector Diagram.... 9 Partition Profile Section... 10 Adjustability.... 11 Ceiling & Floor
More informationGuide Specification Section Interior Aluminum Doors and Frames
Guide Specification Section 08 11 16 Interior Aluminum Doors and Frames SECTION 08 11 16 The Sliding Door Company s door and frame system includes glazed swing doors, sidelights, transoms, and fixed panels
More information2.01 Standard Entrances Description
2.01 Standard Entrances Description Description Tubelite Standard Entrances have an outstanding reputation for craftsmanship and strength. The Narrow Stile Door has a face dimension of 2 1/8" and is designed
More informationSeries D200 Narrow Stile Series D300 Medium Stile * D500 Wide Stile ** Standard Aluminum Swing Entrance Doors
E F C O C O R P O R A T I O N Visit us on the web at efcocorp.com IMPACT GRADE BALLISTIC GRADE Series D200 Narrow Stile Series D300 Medium Stile * D500 Wide Stile ** Manufacturer Configurations Narrow
More informationGuide Specification Section Interior Suspended Sliding Glass Doors
Guide Specification Section 08 32 13 Interior Suspended Sliding Glass Doors SECTION 08 32 13 The Sliding Door Company s product combines operable sliding glass doors with stationary glazed panels to create
More informationPRODUCT DATA CATALOG
PRODUCT DATA CATALOG CONTENTS PAGE STANDARD ELEVATIONS 2 STANDARD ELEVATIONS 3 DOOR SPECIFICATIONS 4 LOUVER SPECIFICATIONS 5 GLAZING SPECIFICATIONS 5 DOOR HANDING CHART 6 CLINE STANDARD HARDWARE LOCATIONS
More informationCYPRESS FAIRBANKS MEDICAL CENTER HOSPITAL
T Architecture Interiors Planning 1165 BRITTMOORE RD. HOUSTON, TEXAS 7704 (T) 71.626.400 (F) 71.626.401 in association with: www.garnerfritsche.com CYPRESS FAIRBANKS MEDICAL CENTER HOSPITAL An HCA Affiliated
More informationDIVISION Hardware
FORMAT 1. Technical specifications content and numbering system shall be based on the most current CSI Master Format. BASIS OF DESIGN 1. APSU design standards shall not replace fully developed, project
More informationSCI-FAB Product Specifications. Casework Section 1. Part 1 General
SCI-FAB Product Specifications Casework Section 1 Part 1 General 1.1 SCOPE OF WORK Includes all factory fabricated stainless steel casework as required by the project drawings. 1.2 TYPICAL INCLUSIONS A.
More informationProduct Guide Specification
Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat,
More informationMOVEABLE GLASS WALL TECHNICAL DATA
Ideal for applications requiring space division, visibility, and security. Used in banks, office lobbies, conference areas, interior storefronts, and arena skyboxes. Clean look of secure, yet easily moveable
More informationADDENDUM NO. 2. Germania Club Renovation Phase 2. Saginaw County Community Mental Health Authority WILLIAM A. KIBBE & ASSOCIATES, INC.
ADDENDUM NO. 2 PROJECT: OWNER: ENGINEER / ARCHITECT: PROJECT LOCATION: Saginaw County Community Mental Health Authority Germania Club Renovation Phase 2 Saginaw County Community Mental Health Authority
More informationADDENDUM No. 4 Page 1 of 8 (includes attachment)
ADDENDUM No. 4 Page 1 of 8 (includes attachment) Date Issued: November 27, 2017 Project: TOWNSHIP OF NORWICH FIRE SERVICE STATION No: 3 BURGESSVILLE, ONTARIO 385435 HIGHWAY 59, BUGESSVILLE, ONTARIO N0J
More informationCLEAR GLASS WALL SYSTEMS
CLEAR GLASS WALL SYSTEMS SERIES SI3000C Clean, uninterrupted views. Series SI3000C Clear Glass Walls create a seamless wall with uninhibited views. Clear Glass Walls eliminate vertical stiles, allowing
More informationARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)
ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI) PROJECT: Villa Joseph Marie High School - Auditorium Addition ARCHITECTS PROJECT NO: 2339 ASI NO: 001 DATE OF ISSUANCE: 12/5/2017 TO: Twining Construction Co.
More informationAddendum. Windsor Hall Renovations Date: October 12, 2017 Addendum No: 3 GENERAL. 1! Addendum #4 will be issued 2:00 PM Tuesday October 17, 2017.
!!! Addendum EXP Project No: MTA Project No: WIND-17-01 Project: Windsor Hall Renovations October 12, 2017 Addendum No: 3 The following information supplements and/or supersedes the bid documents. This
More informationPRODUCT DATA CATALOG
PRODUCT DATA CATALOG CONTENTS PAGE STANDARD ELEVATIONS 2 STANDARD ELEVATIONS 3 DOOR SPECIFICATIONS 4 LOUVER SPECIFICATIONS 5 GLAZING SPECIFICATIONS 5 DOOR HANDING CHART 6 CLINE STANDARD HARDWARE LOCATIONS
More informationWayne State University. Prentis Building Renovation. NM Project Number: Niagara Murano 2215 Cole Street Birmingham, Michigan, 48009
ADDENDUM NO 2 OWNER: Wayne State University DATE: January 4 th, 2019 PROJECT: NM Project Number: 18113.0 ARCHITECT: ENGINEER: Niagara Murano 2215 Cole Street Birmingham, Michigan, 48009 IMEG 26200 Town
More informationHIA AIR CARGO HAMILTON ADDENDUM #3. Addendum No. A03 (Architectural) o Text 1 page o SK-10a o SK-10b o SK-11
HIA AIR CARGO HAMILTON ADDENDUM # (This Addendum consists of six () pages) Cover sheet Schedule time lines for Architectural Precast, Miscellaneous Metals, Insulated Metal Panels, Roofing and Aluminum
More informationCLEAR GLASS WALL SYSTEMS
PRODUCT DATA SHEET SERIES SI3000C CLEAR GLASS WALL SYSTEMS Clean, Uninterrupted Views Series SI3000C Clear Glass Walls eliminate vertical stiles, allowing for maximum transparency, natural daylighting,
More informationSECTION INTERIOR SIGNAGE
SECTION 10 14 02 INTERIOR SIGNAGE PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by
More informationRENOVATION OF THE FARMERS MARKET Reference Number:
RENOVATION OF THE FARMERS MARKET Reference Number: 13-098 A D D E N D U M NO. 1 The following shall form part of the tender documents issued by the City of Guelph s Purchasing Department, June, 2013. NOTE:
More informationSECTION Display Case Door Series 1301-CM
1 SECTION 12 3559 Display Case Door Series 1301-CM PART 1 - GENERAL 1.01 SUMMARY A. This section includes: 1. Display Case Glass Doors. 2. Sidelites. B. Related work in other sections: 1. 08 8000- Glazing
More informationADDENDUM NOTICE INTERIOR RENOVATIONS AT THE BATHURST CLARK RESOURCE LIBRARY, 900 CLARK AVENUE WEST, VAUGHAN, ON
The City of Vaughan Procurement Services Department 2141 Major Mackenzie Drive Vaughan, ON L6A 1T1 Tel (905) 832-8555 ADDENDUM NOTICE ADDENDUM NO. 3 Total of (5) page BID NO. T18-003 DESCRIPTION: INTERIOR
More informationDivision 08. Openings
Division 08. Openings 08 10 00. Doors and Frames 08 11 00. Metal Doors and Frames 1. All fire rated doors shall be metal. 2. Contractors shall remove all rating labels from doors/frames that are not installed
More informationInfinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE
Infinity 20 Min Note: 20 Minute (Positive Pressure) Category A & B Manufacturing Specifications MAXIMUM SIZES All doors shall have a minimum thickness of 1-3/4" + 1/16" Single Swing: 4/0 x 9/0 Standard
More information.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.
PAGE 1 PART 1 GENERAL 1.1 REFERENCE.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. 1.2 RELATED WORK SPECIFIED ELSEWHERE.1 Installation
More informationSECTION FINISH HARDWARE
SECTION 08710 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Finish Hardware as shown and detailed on the Drawings
More informationINVITATION TO TENDER ITT No. PS FIRE HALL 5 + HOUSING CONSTRUCTION. ADDENDUM No. 2 and AMENDMENT No. 2
FINANCE, RISK AND BUSINESS PLANNING Supply Chain Management May 17, 2016 INVITATION TO TENDER ITT No. PS20160468 FIRE HALL 5 + HOUSING CONSTRUCTION ADDENDUM No. 2 and AMENDMENT No. 2 RE: Various additions
More information12560 W. Cedar Drive Lakewood, CO Barry Himmelman President
Denver Public Schools Purchasing Department 1617 S. Acoma St. Denver, Colorado 80223 INVITATION TO BID 16-BS-2260 ADDENDUM NUMBER FOUR January 8, 2016 THIS ADDENDUM MUST BE ACKNOWLEDGED. THIS ADDENDUM
More informationDIVISION 8 DOORS AND WINDOWS. 1. Exterior and interior single doors shall be 1-3/4 inch thick, 3 feet wide, and 7 feet high, minimum.
8.01 DOORS AND FRAMES (12-2-02) A. Doors DIVISION 8 DOORS AND WINDOWS 1. Exterior and interior single doors shall be 1-3/4 inch thick, 3 feet wide, and 7 feet high, minimum. 2. Where required for maintenance
More informationb. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube
MODEL 240I SECTION 08120 FLUSH ALUMINUM DOORS AND FRAMES PART I GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to deliver and install aluminum doors, frames,
More informationAMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS A. Drawings and General Provisions of Contract, including General and Supplementary Conditions and
More informationSECTION FOLDING GLASS PANEL PARTITIONS
SECTION 10 22 26.35 FOLDING GLASS PANEL PARTITIONS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED FOLDING GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY, MOUNTING BRACKETS, MOUNTING
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-08 33 13 (May 2009) Change 2-11/12 --------------------------- Preparing Activity: USACE Nontechnical Title Revision (August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationSECTION B INDEX STOREFRONT FRAMING SYSTEMS
SECTION B INDEX STOREFRONT FRAMING SYSTEMS B PAGE DESCRIPTION 01 STOREFRONT FRAMING SPECIFICATIONS 02 175 SERIES 1 3/4" (44.5) X 4 1/2" (114.3) FLUSH GLAZE FRAMING FOR SINGLE GLAZING. 06 200 SERIES 2"
More informationADDENDUM NO. 1 November 10, 2016
COUER D ALENE CITY HALL PROJECT NO. 2016-009 REMODEL AND ADDITION COEUR D ALENE, IDAHO ADDENDUM NO. 1 November 10, 2016 This addendum is hereby incorporated into and is an integral part of the bidding
More informationPOST BID ADDENDUM TWO
POST BID ADDENDUM TWO DATE: March 4, 2016 PROJECT: Ingham County Human Services Building Renovation Packet No. 96-15 PROJECT #: 14-614 This Addendum is issued for the purpose of modifying and/or clarifying
More informationcustom entrances and hardware
custom entrances and hardware Table of Contents Custom Entrances (B1) Loose Hardware and Fabrication (B2) Custom Entrances and Modifications (B1) Table of Contents Entrance Door Handing page 3 CUSTOM ENTRANCES
More informationWOOD AND CLAD COMMERCIAL DOOR WOOD AND CLAD 2 1/4 COMMERCIAL DOOR. Table of Contents
WOOD AND CLAD COMMERCIAL DOOR WOOD AND CLAD 2 1/4 COMMERCIAL DOOR Table of Contents PAGE History... 2 Part Identification Wood Commercial Door XX RHRA... 3 Part Identification Wood Commercial Door Stationary
More informationB. Division-16 Basic Materials and Methods section apply to work specified in this section.
Section 16745 PREMISE CABLING SYSTEMS PART ONE GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification
More informationBovard Studios Inc. Section April 6, 2004 Page 1
April 6, 2004 Page 1 This section includes solid flush and surface articulated wood doors, may have veneer facing, solid or glazed (stained glass) design, factory pre-fit, may be factory finished or site
More informationENTRY DOOR TEST REPORT. Rendered to: The Vistawall Group
ENTRY DOOR TEST REPORT Rendered to: The Vistawall Group Product: Single 500 Wide Stile Outswing Full-Lite Aluminum Entry Door w/ Standard TH-43 Threshold and Woolpile Weathering Title Air Infiltration@
More informationB. Section Rough Carpentry: Support framing, grounds, and concealed blocking.
SECTION 06 41 00 - ARCHITECTURAL WOOD CASEWORK PART 1: GENERAL 1.1 SECTION INCLUDES A. Specially fabricated cabinet units. B. Cabinet hardware. C. Factory finishing. 1.2 RELATED REQUIREMENTS A. Division
More informationFOLDING GLASS WALL SYSTEMS
FOLDING GLASS WALL SYSTEMS SERIES SI3000 A seamless wall with endless possibilities. Series SI3000 Aluminum Folding Glass Wall Systems have been a signature product of Solar Innovations since their introduction
More informationSECTION 10520: FIRE EXTINGUISHERS AND CABINETS
SECTION 10520: FIRE EXTINGUISHERS AND CABINETS PART 1 GENERAL 1.01 GENERAL REQUIREMENTS: A. This section specifies fire extinguishers, cabinets for fire extinguishers, fire and other accessories. Their
More informationProject No: Date: 02 September To: The Des Plaines Public Library Issued by: Lisa Schmidt
ADDENDUM Project: Des Plaines Public Library Renovations Addendum No. 01 Project No: 13300 Date: 02 September 2015 To: The Des Plaines Public Library Issued by: Lisa Schmidt ATTN: ALL FFE BIDDERS Senior
More informationSTANDARD ENTRANCES TECHNICAL MANUAL
TECHNICAL MANUAL FEATURES FEATURES Narrow stile doors have a 2 1/2" top rail, 3 7/16" bottom rail, and 2 1/16" vertical stiles Medium stile doors have a 3 7/16" top rail, 6 7/16" bottom rail, and 3 7/16"
More informationEncore 20 Min. FIRE RATED DOORS WARNOCK HERSEY ENCORE - STANDARD PANEL - 20 MIN. RATING
Encore 20 Min 20 Minute (Positive Pressure) - Category B Manufacturing Specifications MAXIMUM SIZES All doors shall have a minimum thickness of 1-3/4" + 1/16" Single Swing: 4/0 x 8/0 Standard Pair: 8/0
More informationHookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel
Mortise Locks deadlatch Deadbolt Hookbolt Function: Deadbolt, Hookbolt, Deadlatch Backset: 31/32", 1-1/8", 1-1/2" Face Plate: 1"W x 6-7/8" L - Aluminum Case Dimensions: 7/8"W x 6"L x Depth specific to
More informationMortise Locks. European Mortise Locks Series EML Features Ordering String Functions Trim Sets European Profile Cylinders Specifications
2 Mortise Locks 2 c 3 4 6 9 22 24 European Mortise Locks Series EML Features Ordering String Functions Trim Sets European Profile Cylinders Specifications 2016 02 2 FSB North America European Mortise Lock
More informationAddendum #1 - Bid Package #
Addendum #1 - Bid Package #6929-08 Project Name: Lincoln Public Schools District Office 5901 O Street Lincoln, NE Project No.: 11065 Issued: September 18, 2012 This Addendum is issued by Hampton Construction
More informationPERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY. PRODUCT TYPE: 6' x 8' Double Inswing Hardwood Door with Half Circle Transom
PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY PRODUCT TYPE: 6' x 8' Double Inswing Hardwood Door with Half Circle Transom Title Uniform Load Deflection Test Pressure Uniform Load Structural
More informationHAYES VALLEY PLAYGROUND AND CLUBHOUSE PROJECT NO.: SAN FRANCISCO PARKS AND RECREATIONS SAN FRANCISCO, CA
HAYES VALLEY PLAYGROUND AND CLUBHOUSE PROJECT NO.: 08012.00 SAN FRANCISCO PARKS AND RECREATIONS SAN FRANCISCO, CA ADDENDUM NUMBER 1 to the BID SET August 10, 2009 General This Addendum will become part
More informationSECTION A4...IMPACT RATED ENTRANCES* 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5
CONTENTS SECTION A4...IMPACT RATED ENTRANCES* Impact Rated Entrances CONTENTS PAGE FINISH GROUPS... A4/3 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5 A4/1 350 IR/500 IR BASE DOOR DOOR CHASSIS...
More informationB. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.
McKee and Associates Architecture and Interior Design Addendum No. THREE Date: 12.11.17 Project: A NEW BUILDING FOR THE GREATER LIMESTONE COUNTY CHAMBER OF COMMERCE ATHENS, ALABAMA A3.1 GENERAL PROJECT
More informationCOUNTY OF NORTHUMBERLAND Addendum No. 3 Request for Quotations To Renovate the Grafton Recreation Centre for a Licensed Child Care Centre
April 12, 2019 COUNTY OF NORTHUMBERLAND Addendum No. 3 Request for Quotations 19-10 - To Renovate the Grafton Recreation Centre for a Licensed Child Care Centre The attached information, questions and
More informationSECTION WOOD DOORS
SECTION 08211 WOOD DOORS Notice to Vendors: CANV prefers to purchase products that contain tropical wood only if they are certified according to the guidelines of the Forest Stewardship Council (FSC).
More informationDesign and Construction Standards SECTION ATHLETIC LOCKERS
SECTION 10505 ATHLETIC LOCKERS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. The provisions of the General Conditions, Supplementary Conditions, and the Sections included under Division 1, General Requirements,
More informationSuperior by Design. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT
Superior by Design. Euro PIVOT Door Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL 22410 www.euro-wall.com 888.989.EURO (3876) FOLDING SLIDING STACKING PIVOT
More informationArchitectural Alliance Incorporated KEYPLAN SCALE:N.T.S. SECOND FLOOR DEMOLITION FLOOR PLAN 2 SCALE:1/4" = 1'-0"
KEYPLAN SCALE:N.T.S. SECOND FLOOR DEMOLITION FLOOR PLAN SCALE:/4" = '-0" SECOND FLOOR DEMOLITION FLOOR PLAN SCALE:/4" = '-0" P P 08 /A30 KEYNOTES. ALTERNATE # RE-LAMINATE CABINET.. NEW BLINDS 3. WRAP HEAD,
More informationTG Glazing Design-Build
TG08.1 - Glazing Design-Build Question No. 0040 0041 0042 0043 Submission Date Question 7.14.2011 Is it acceptable to use 304 stainless in lieu of 316 where the material will be painted per 09 97 15? 7.14.2011
More information6200 Series. System Components Series Electric Strikes
6200 Series Strikes for Mortise or Cylindrical Devices Models 6210, 6211, 6211AL, 6211WF, 6212, 6212WF, 6213, 6214, 6215, 6216, 6221, 6222, 6223, 6224, 6224AL, 6225 & 6226 System Components 6200 Series
More informationINTELLIKEY. Lock Identification GENIUS AT YOUR FINGERTIPS. 1 rev:
INTELLIKEY R GENIUS AT YOUR FINGERTIPS Lock Identification 1 rev: 073103 rev: 073103 2 Easy Lock Identification Mortise Lockset Shown at left is a standard mortise function lockset. The cylinder is normally
More informationFLUSHLINE ENTRANCES. Features
OCTOBER, 2006 FLUSHLINE ENTRANCES FEATURES 1 Features Flush appearance with a face sheet of fiberglass reinforced polyester (FRP) or aluminum, that is captured on four sides by integral extruded reglets
More informationSECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT
SECTION 220553 - IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT Henderson Engineers, Inc. PART 1 - GENERAL REQUIREMENTS 1.1 SUMMARY A. Extent of Plumbing work to be identified as required by this Section
More informationADDENDUM #1. April 29, 2009
April 29, 2009 Re: HACC, Central Pennsylvania s Community College Midtown 1 CCTA Phase 2 Solicitation # 09-17 From: Eastern pcm, LLC Construction Manager HACC 212 Locust Street, Suite 604 Harrisburg, PA
More informationNARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions
NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE Installation Instructions PART Y015 JUNE 2016 Table of Contents Section 1. GENERAL NOTES AND GUIDELINES... 2. DOOR HARDWARE A. Locks B. Push/Pulls
More informationAdams rite. Deadbolts, Deadlocks & Hookbolts Series maximum security laminated deadlocks/hookbolts
1850 Series maximum security laminated deadlocks/hookbolts dams rite Deadbolts, Deadlocks & Hookbolts For single leaf doors where the gap between door and jamb is large ccepts standard mortise cylinder
More informationYour global resource for quality commercial door hardware. Euroline Catalog Euroline Catalog
Your global resource for quality commercial door hardware. Catalog Catalog More for your door than any other brand. TM Industry-Leading Service For more than 158 years, Hager Companies has led the industry
More informationTubular Deadbolts. Deadbolt Series HDD Features Ordering String HDD Functions Trim Sets Suggested Specification
4 Tubular Deadbolts 3 4 6 8 17 Deadbolt Series HDD Features Ordering String HDD Functions Trim Sets Suggested Specification 3 12 14 16 17 Keyed Deadbolt Series KDD Features Ordering String KDD Functions
More informationENVIRONAMICS SLIMLINE GLASS WALL ARCHITECTURAL DETAILS
ENVIRONAMICS SLIMLINE GLASS WALL ARCHITECTURAL DETAILS Slimline Wall Specifications & Details Table of Contents Page Architectural CSI Specifications 3-6 Elevation keyed to hard bead details 7 Elevation
More informationPlease read and understand all instructions before beginning. These instructions cover the non-impact aluminum French Door 101.
The performance and proper operation of a door is only as good as the installation. By following these instructions, the probability of a good installation greatly increases. Please read and understand
More informationDB1000 SERIES. Heavy-Duty Tubular Grade 1 Deadbolts. Standard Features. Optional Features. Options
DB1000 SERIES Heavy-Duty Tubular Grade 1 Deadbolts Standard Features n Performance Complies with ANSI A156.5, Grade 1, 250,000 cycles n Chassis Tubular, steel n Deadbolt 1" x 2-1/4", square corner faceplate,
More informationLift & Slide W6400. (rev )
Copyright 2010 Pacific Architectural Millwork All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means without permission by Pacific Architectural Millwork.
More informationKidsAbility Guelph Hub Renovation ADDENDUM #2 Project No.:
KidsAbility Guelph Hub Renovation ADDENDUM #2 This Addendum amends and forms part of the Bidding and Contract Documents for the above Project as follows: CLARIFICATIONS Q1. Is it possible to set up a secondary
More informationOFFSET PIVOTS STOREFRONT HARDWARE
Trans-Atlantic offset pivots are used for both flush face frame installations and ⅛" recessed door applciations. Pivots replace most major door manufacturers. Suitable for aluminum doors weighing up to
More informationSUPERIOR COURT OF CALIFORNIA NORTH BUTTE COUNTY COURTHOUSE JBCP201205BR ADDENDUM NO. 5. February 25, 2013
SUPERIOR COURT OF CALIFORNIA NORTH BUTTE COUNTY COURTHOUSE JBCP201205BR ADDENDUM NO. 5 February 25, 2013 Owner: Architect: Administrative Office of the Courts 2860 Gateway Oaks Drive, Suite 400 Sacramento,
More informationADDENDUM NO. TWO. To the Plans and Specifications for: PALM COAST READINESS CENTER PALM COAST, FL For FLORIDA DEPT. OF MILITARY AFFAIRS
ADDENDUM NO. TWO To the Plans and Specifications for: PALM COAST READINESS CENTER PALM COAST, FL For FLORIDA DEPT. OF MILITARY AFFAIRS Prepared By: ARCHITECT Bhide & Hall Architects, P.A. 1329-C Kingsley
More informationSECTION SIGNAGE
SECTION 10 14 00 SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification section, apply
More informationSLIDING DOOR SYSTEM_ S34 PRODUCT LIST. System description Accessories
SLIDING DOOR SYSTEM_ S34 PRODUCT LIST System description Accessories SLIDING DOOR SYSTEM_ S34 1.0_ System description_ page 03 2.0_ Profiles_ page 04 3.0_ Profile finishes_ page 08 4.0_ Panels_ page 09
More informationPHYSICAL FACILITIES Consultant s Handbook Division 08 Openings 7400 Access Control Hardware. Page 1 of 6
1 Definitions Vending Laundry Copy Office/Retail Outlet Door Switch Controlled Door Card Reader Door LX Switch RX Switch Power Transfer Mortise Type Non- consisting of beverage and/or snack machines to
More information7.01. Door Hardware & Accessories
7.01 Door 7.02 Mid-Panel Concealed Vertical Rod Panic First Choice 3100 Series Exit Device 7.03 P092 Mortised Butt Hinge Both leaves of this hinge are punched and countersunk so they can be mortised into
More informationYSD 400 Sliding Door System Installation Manual
System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION
More informationThermally Broken Framing and Door Installation
INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.
More informationDOOR SAVERS AVAILABLE IN STEEL, STAINLESS STEEL (32D), BRIGHT BRASS (3), BRONZE (10) AND OIL RUBBED BRONZE (10B)
SAVERS K1 : 9 High For cylindrical locksets 2-1/8 bore, 2-3/8 and 2-3/4 backsets K 188 2-3/8 1-3/8 K 184 2-3/8 1-3/4 K 148 2-3/4 1-3/8 K 144 2-3/4 1-3/4 K5 144 5 SPECIFY K3 : 9 High For cylindrical locksets
More informationPivots / Padlocks / Hasps
/ Padlocks / Hasps 046-6270 046-770 Master Lock 6270 Solid Steel Shackleless Round Padlock and 770 Security Hasp Padlock 2-7/8 round body Available cylinders: W6000 5-pin, W7000 6-pin, AM W600A 5-pin,
More informationSECTION CUSTOM CASEWORK
PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 06 41 00 CUSTOM CASEWORK A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification sections,
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-08 51 69.10 (April 2006) ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-08582 (August 2001) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationEURO (3876) Euro-C2 Installation Instructions Euro-Wall Systems, LLC
888.989.EURO (3876) www.euro-wall.com Euro-C2 Installation Instructions Installation Instructions Euro-C2 step A.1) Assemble Bottom corner Pre-caution: it is recommended to use screw wax to prevent screw
More informationCONTENTS. Custom Entrances and Hardware
CONTENTS A2/1 CONTENTS SECTION A2...CUSTOM ENTRANCES AND HARDWARE* PAGE PRICING EXAMPLES... A2/3 A2/4 190/350/500 BASE DOOR DOOR CHASSIS... A2/5 DOOR GLAZING/WEATHERING OPTIONS... A2/6 DOOR BOTTOM RAIL
More informationPUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20
Flat Goods Section TABLE OF CONTENTS EXIT DEVICES PUSH BAR EXIT DEVICES N1500 Heavy Duty Rim Exit Device N1550 Rim Exit Device... 6 N1650 Fire Rated Heavy Duty Exit Device N1700(F) Vertical Rod Heavy Duty
More informationSECTION WOOD ACCORDION FOLDING DOORS
SECTION 08 3513 WOOD ACCORDION FOLDING DOORS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Wood accordion folding doors. B. Related Sections: 1. Division 01: Administrative, procedural, and temporary
More informationP O S T E R C A S E S D I S P L A Y C A S E S M E S S A G E B O A R D S E X H I B I T C A S E S D I R E C T O R I E S W W W. P O B L O C K I.
SPECIALTY DISPLAY CATALOG P O S T E R C A S E S D I S P L A Y C A S E S M E S S A G E B O A R D S E X H I B I T C A S E S D I R E C T O R I E S W W W. P O B L O C K I. C O M W H AT C A N W E D O? I T S
More informationSECTION DOOR HARDWARE
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 08 71 00 1. Use this section only for NCA projects. 2. Delete between // --- // if not applicable to project. Also delete any other item or paragraph not applicable
More informationSECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE
1 SECTION 10 2880 FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationQUOTATION FOR THE INTERIOR FURNISHING WORK OF BANK OF INDIA, BALARAMAPURAM BRANCH.
QUOTATION FOR THE INTERIOR FURNISHING WORK OF BANK OF INDIA, BALARAMAPURAM BRANCH. Date:- Si.No. Description of work Qty Units Rate Amount I DOORS & PARTITIONS :- 1 FULLY GLAZED FULL HEIGHT PARTITION WITH
More information