McQuay. Commercial Unitary Rooftop Cooling with Gas Heat. LGA 088, 100 Design 1. Last Manufactured: 2004

Size: px
Start display at page:

Download "McQuay. Commercial Unitary Rooftop Cooling with Gas Heat. LGA 088, 100 Design 1. Last Manufactured: 2004"

Transcription

1 Replacement Parts List No New 08/2011 McQuay Commercial Unitary Rooftop Cooling with Gas Heat LGA 088, 100 Design 1 Last Manufactured: 2004 To find your Daikin Applied parts distributor, call or visit

2 Contents Parts List Revision History...3 Nomenclature- Unit Model Number...4 Diagrams Unit Assembly...5 Damper Assembly...5 Gas Heat Section...6 Control Panel...6 Blower Section...7 Power Exhaust...7 LGA 088S Components LGA 088H Components LGA 100S Components Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 2

3 Parts List Revision History Revision Date Description New 08/11 New. Daikin Applied, Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN (763) Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 3

4 Nomenclature Unit Model Number LGA 088 H S 1 G 02D1H 125 B DE SS G YY D1 G FY SR LTL Y 1 P Unit Type LGA= Commercial Rooftop- Cooling with Gas Heat 02 Unit Size 088= 7.5 Tons Cooling 100= 8.5 Tons Cooling 03 Cooling Efficiency S= Standard Efficiency H= High Efficiency 04 Heat Type S= Low Gas Heat H= High Gas Heat 05 Revision Number 1= 1st Revision Number 06 Voltage Y= 208/230/60/3 G= 460/60/3 J= 575/60/3 M= /50/3 07 Supply Fan Motor and Drives 02 D1 H 02= 2 HP 03= 3 HP 08 Heating Capacity 125= 125 MBH Natural Gas Input- Aluminized Steel 180= 180 MBH Natural Gas Input- Aluminized Steel 12S= 125 MBH Natural Gas Input- Stainless Steel 18S= 180 MBH Natural Gas Input- Stainless Steel 09 Unit Configuration B= Bottom Supply & Return H= Horizontal Supply & Return 10 Outside Air Options YY= None DE= 0-100% Economizer, Motorized AY= 0-25% OA, Manual AE= 0-25% OA, Motorized H= High Efficiency Motor S= Standard Efficiency Motor D1= Drive #1: RPM D2= Drive #2: RPM D3= Drive #3: RPM D4= Drive #4: RPM 12 Exhaust Options Y= No Exhaust Dampers G= Gravity Exhaust Damper P= Powered Exhaust Fan 13 DDC Controls YY= Thermostat Control- Main DDC Board Only 14 Field Power Connection and Disconnect D1= With Disconnect Switch Y1= No Disconnect Switch 15 Ground Fault Interrupter Outlet Y= None G= GFI Outlet- 15A 16 Air Flow Sensors FB= Dirty Filter Switch & Blower Proving Switch FY= Dirty Filter Switch only YB= Blower Proving Switch only YY= No Air Flow Sensors 17 Smoke Detectors SR= Supply & Return Smoke Detectors SY= Supply only Smoke Detector YR= Return only Smoke Detector YY= No Smoke Detector 18 Packaging Options LTL= LTL Crating= Replacement/Bottom RA YYY= None 19 Refrigerant Piping Options Y= No Service Valves S= Service Valves- Discharge & Liquid Lines 20 Technicoat Y= None 1= Outdoor Condenser Coil only, Painted Base Section 2= Indoor Evap Coil only, Painted Blower Housing and Base 3= Cond. & Evap. coils, Painted Base Section & Painted Blower Housing and Base 21 Condensate Drain Trap Y= Field Provided P= PVC Trap Package C= Copper Trap Package 11 Economizer Control Options SS= Single Sensor/Sensible Control SE= Single Sensor/Enthalpy Control DE= Dual Sensor/Enthalpy Control GS= DDC/Sensible Control GE= DDC/Enthalpy Control Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 4

5 Unit Assembly Diagram Damper Assembly Diagram Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 5

6 Gas Heat Section Diagram Control Panel Diagram Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 6

7 Blower Section Diagram Power Exhaust Diagram Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 7

8 LGA 088S Components Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 8

9 LGA 088S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 9

10 LGA 088S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 10

11 LGA 088S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 11

12 LGA 088S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 12

13 LGA 088S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 13

14 LGA 088S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 14

15 LGA 088S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 15

16 LGA 088S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 16

17 LGA 088H Components Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 17

18 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 18

19 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 19

20 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 20

21 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 21

22 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 22

23 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 23

24 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 24

25 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 25

26 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 26

27 LGA 088H Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 27

28 LGA 100S Components Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 28

29 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 29

30 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 30

31 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 31

32 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 32

33 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 33

34 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 34

35 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 35

36 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 36

37 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 37

38 LGA 100S Components, Continued Commercial Unitary Rooftop: LGA 088, 100 Design 1 New 08/11 RPL / Page 38

Commercial Refrigeration Price List

Commercial Refrigeration Price List Commercial Refrigeration Price List KPL3_004_073118 Effective Date: August 1, 2018 Krack Commercial Refrigeration Price Lists are updated quarterly; January, April, July and October; and posted on our

More information

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION GUIDE SPECIFICATIONS 256920-UGS-A-0506 Simplicity Intelli-Comfort Optional Control in 3-25 Ton Packaged Units GENERAL DESCRIPTION CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP Equipment with Simplicity

More information

2017 Price List. Krack Corporation Hussmann Corporation St. Charles Rock Rd. Bridgeton, MO Phone: Fax:

2017 Price List. Krack Corporation Hussmann Corporation St. Charles Rock Rd. Bridgeton, MO Phone: Fax: Expires: 1/1/2018 2017 Price List Changes since the last Price List: 3.5% Price Increase Effective August 15th Correct SV evaporators pricing. Changes on previous revision: Correct rupture disc assembly

More information

ADDENDUM NO. 4 November 15, Page 1

ADDENDUM NO. 4 November 15, Page 1 ADDENDUM NO. 4 November 15, 201 8 Page 1 PROJECT MANUAL FOR CONSTRUCTION OF HVAC REPLACEMENT FOR NORTH OCONEE HIGH SCHOOL FOR OCONEE COUNTY SCHOOLS WATKINSVILLE, GEORGIA DATED: SEPTEMBER 14, 2018 CUNNINGHAM,

More information

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL SECTION 23 00 10 - MECHANICAL SCOPE OF WORK PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01

More information

TECHNICAL SUPPORT MANUAL Fan Coils FXM4X

TECHNICAL SUPPORT MANUAL Fan Coils FXM4X Fan Coils FXM4X DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product

More information

TECHNICAL SUPPORT MANUAL Fan Coils

TECHNICAL SUPPORT MANUAL Fan Coils Fan Coils FEM*X, WAHM, WAHT DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used

More information

VEXUS TROUBLESHOOTING GUIDE MINI SPLIT SYSTEM EV10C2DB6 / H10C2MR63 EV13C2DB6 / H13C2MR63 EV18C2DB6 / H18C2MR63 EV24C2DB6 / H24C2MR63

VEXUS TROUBLESHOOTING GUIDE MINI SPLIT SYSTEM EV10C2DB6 / H10C2MR63 EV13C2DB6 / H13C2MR63 EV18C2DB6 / H18C2MR63 EV24C2DB6 / H24C2MR63 VEXUS TROUBLESHOOTING GUIDE VEXUS E1 EV10C2DB6 / H10C2MR63 VEXUS EV13C2DB6 / H13C2MR63 EV18C2DB6 / H18C2MR63 EV24C2DB6 / H24C2MR63 MINI SPLIT SYSTEM Troubleshooting Indoor unit error display Display Operation

More information

Industrial Pipe Marking

Industrial Pipe Marking Industrial Pipe Marking Pipe and Valve Identification Specialists SPECIFICATIONS ASME (ANSI) Standard A13.1-2007 The ASME (ANSI) Standard for pipe identification is a widely used guideline in determining

More information

13acd MERIT SERIES R 22 A I R C O N D I T I O N E R S. SEER up to to 5 Tons Cooling Capacity 17,500 to 60,000 Btuh

13acd MERIT SERIES R 22 A I R C O N D I T I O N E R S. SEER up to to 5 Tons Cooling Capacity 17,500 to 60,000 Btuh E N G I N E E R I N G D A T A A I R C O N D I T I O N E R S 13acd MERIT SERIES R 22 Bulletin No. 210423 April 2008 Supersedes January 2008 SEER up to 14.0 1.5 to 5 Tons Cooling Capacity 17,500 to 60,000

More information

The Ins and Outs of Basic. A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate.

The Ins and Outs of Basic. A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate. Part 3 The Ins and Outs of Basic Sch ematic Symbols A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate. B y H o w a r d L. P e m p e r, C

More information

SmartZone-2 & SmartZone-4

SmartZone-2 & SmartZone-4 SmartZone-2 & SmartZone-4 Quick-Start Guide UPDATED 2011-7-26 This guide is intended to give the installer a brief set of instructions about how to set up the XCI Zoning SmartZone System. For more detailed

More information

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards The Solo, Select and Sync PWM boards provide a pulse-width modulated (PWM) signal to the EC motor to control fan speed.

More information

TECHNICAL SUPPORT MANUAL Builder Series TXV Cased Coils EBU2X

TECHNICAL SUPPORT MANUAL Builder Series TXV Cased Coils EBU2X Builder Series TXV Cased Coils EBU2X DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is

More information

2-pole design. New: Semi-hermetic compressors with 2-pole drive motor for mains voltages of 60 Hz. Now for 60 Hz mains voltage

2-pole design. New: Semi-hermetic compressors with 2-pole drive motor for mains voltages of 60 Hz. Now for 60 Hz mains voltage 2-pole design Semi-hermetic compressors with 2-pole drive motor for mains voltages of Hz New: Now for Hz mains voltage Baureihe HG series HG 2-pole 2-polig - t a glance t a glance Based on our compressors

More information

SPLIT DUCTED UNIT TECHNICAL SELECTION DATA SRA141C / SRA140E SPECIFICATION SUMMARY UNIT FEATURES CONTROL FEATURES CONTROL OPTIONS. PLENUMS (Optional)

SPLIT DUCTED UNIT TECHNICAL SELECTION DATA SRA141C / SRA140E SPECIFICATION SUMMARY UNIT FEATURES CONTROL FEATURES CONTROL OPTIONS. PLENUMS (Optional) TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 1 SINGLE PHASE SCROLL SINGLE STAGE SS M SOFT START CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Single Phase Soft Starter

More information

M1.0 MECHNANICAL FLOOR PLAN

M1.0 MECHNANICAL FLOOR PLAN GENERAL NOTES A. CONTRACTORS AND SUB CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY

More information

2250 S LOCUST APARTMENT IMPROVEMENTS EXPENSES

2250 S LOCUST APARTMENT IMPROVEMENTS EXPENSES APT #1 APT #1 11/12/2014 NEW GARAGE LOCKS $ 89.00 11/12/2014 NEW LOCKS $ 169.80 1/11/2015 GARAGE KEY COPIES $ 6.47 1/23/2015 PLUMBING REPAIRS REPLACED MAIN BATH SINK PIPES $ 299.76 2/2/2015 PAINTING $

More information

AWUF Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features

AWUF Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features Series Wall-Mount Air Handler 1½ to 3 Tons Contents Nomenclature...2 Accessories...2 Product Specifications...3 Dimensions...6 Airflow Data...8 Wiring Diagram...9 Product Features Equipped with a Check

More information

*L and *G Series 78+, 80+ and 90+ Models

*L and *G Series 78+, 80+ and 90+ Models REPLACEMENT PARTS LIST *L and *G Series 78+, 80+ and 90+ Models *G6RA and G6TA 80+Upflow/Horizontal *G6RK 80+Downflow *G6RC, G6RD and *G6TC 90+Upflow/Horizontal *G6RL and *G6TL 90+Downflow *LRA 78+Upflow/Horizontal

More information

EQUIPMENT INFORMATION SHEET abbreviations REFRIGERATION - MEDIUM TEMP. Link to PDF file CONTRACTOR QTY

EQUIPMENT INFORMATION SHEET abbreviations REFRIGERATION - MEDIUM TEMP. Link to PDF file CONTRACTOR QTY Back to index ITEM # RM61.1-08CB Notes and EQUIPMENT INFORMATION SHEET abbreviations REFRIGERATION - MEDIUM TEMP. Link to PDF file CONTRACTOR QTY INFORMATION UTILITY INFORMATION EXT NEW MODEL # ITEM DESCRIPTION

More information

W7100A-E Discharge Air Controller

W7100A-E Discharge Air Controller W7100A-E W7100A-E Discharge Air Controller The microprocessor based W7100 Discharge Air Controller maintains an average discharge air (DA) temperature in variable air volume (VAV) cooling systems by modulating

More information

4 T V H A D A A

4 T V H A D A A 4 T V H 0 0 8 6 A D 0 0 0 A A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Name All of units Outline Function Outdoor unit installation manual 1 Outdoor unit user manual 1 Be sure to deliver it to the customer

More information

Evaporator E2 Series. Innovative Refrigeration Solutions. Medium & Low Temperature Models. Issue: 05/14

Evaporator E2 Series. Innovative Refrigeration Solutions. Medium & Low Temperature Models. Issue: 05/14 Evaporator E2 Series Medium & Low Temperature Models Innovative Refrigeration Solutions Issue: 05/14 APPLICATION BENEFITS / FEATURES HIGH EFFICIENCY HEAT EXCHANGER COIL Capacity steps in the range are

More information

Product Launch Package. Refrigeration Marketing Units Emerson Climate Technologies Europe

Product Launch Package. Refrigeration Marketing Units Emerson Climate Technologies Europe Digital Receiver Unit - HLR Product Launch Package Refrigeration Marketing Units Emerson Climate Technologies Europe Emerson Climate Technologies Existing Digital Range Application Outdoor Installations,

More information

Quality Control Checklist - Design Drawings

Quality Control Checklist - Design Drawings Quality Control Checklist - Design Drawings Date Company Name Address Telephone Fax Email Job Number 1) Drawing Set a) Drawing one is site/location/incoming power i) Should contain location map if not

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 SUBMITTALS A.

More information

Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may disqualify Bidder.

Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may disqualify Bidder. ADDENDUM TWO Client: The Abla Griffin Partnership Project Name: Sooner Elementary Media Center Saferoom Project Location: Oklahoma City, OK Issue Date: February 22, 2018 Owner: Moore Public Schools Engineer:

More information

PRESSURE REGULATORS PARKER PRESSURE REGULATING VALVES PRESSURE REGULATORS

PRESSURE REGULATORS PARKER PRESSURE REGULATING VALVES PRESSURE REGULATORS PARKER PRESSURE REGULATING VALVES For R-22, R-502, R-404A, R-507 and other common refrigerants Pilot operated for close control at desired set point. Long life diaphragms. No bellows to fail. Lightweight

More information

2012 IMC Performing Commercial Mechanical Inspections

2012 IMC Performing Commercial Mechanical Inspections 2012 IMC Performing Commercial Mechanical Inspections Based Primarily on the 2012 International Mechanical Code (IMC ) and the 2012 International Fuel Gas Code (IFGC ) as applicable. ` Welcome I am You

More information

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION y GUIDE SPECIFICATIONS 407466-UGS-A-0508 SIMPICITY VAV (VARIABE AIR VOUME) Optional 15-25 Ton Packaged Product Comfort Control System CONTROS SPECIFICATIONS AND CONTRO POINT DATA MAP GENERA DESCRIPTION

More information

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting FANs 216, 121 Technical Bulletin R48 Issue Date 0695 Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting Table of Contents Mounting... 1 Output Control... 2 Wiring...

More information

INSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699)

INSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699) MILLENNIUM HEAD PRESSURE CONTROL KIT FOR LOW AMBIENT APPLICATIONS INSTALLATION INSTRUCTION Supersedes: 530.70-N.8Y (399) 530.70-N.8Y (99) HEAD PRESSURE CONTROL FOR 208/230 & 0V 25, 30 & 0 TON MILLENNIUM

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections:

More information

Pump Package Product Information Model AGZ 025D AGZ 190D Air-Cooled Scroll Chillers

Pump Package Product Information Model AGZ 025D AGZ 190D Air-Cooled Scroll Chillers Installation, Operation and Maintenance Manual IOMM 1110 Group: Chiller Part Number: IM 1110 Date: March 2012 Supersedes: February 2012 Pump Package Product Information Model AGZ 025D AGZ 190D Air-Cooled

More information

technical data air conditioning systems BS box BSVQ-PV1

technical data air conditioning systems BS box BSVQ-PV1 technical data BS box BSVQ-PV1 air conditioning systems BS box BSVQ100-250PV1 TABLE OF CONTENTS BSVQ100-250PV1 1 Specifications....................................................... 2 Technical Specifications.............................................

More information

INSTALLATION MANUAL. Address card EKAC200A

INSTALLATION MANUAL. Address card EKAC200A INSTALLATION MANUAL Address card 4 1 3 1 2 + GND TX+ TX- 3 29 mm 60 mm 20 mm 2 4 READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO NOT THROW IT AWAY. KEEP IT IN YOUR FILES FOR FUTURE REFERENCE.

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION Buebtel/Perlcins Community Learning Center GPD - 2001271.15 SECTION 15075 MECHANICAL IDENTIFICATION PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General

More information

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending

More information

C0330, C0530, C0630, C0830, C1030 Service Parts

C0330, C0530, C0630, C0830, C1030 Service Parts This part list contains the service parts for the air cooled, water cooled and remote air cooled C00, C00, C00, C080, C00 ice machines. To avoid costly and time consuming errors, double check the model

More information

MSU Barnard Hall 105 Cleanroom Installation PPA # Page 1

MSU Barnard Hall 105 Cleanroom Installation PPA # Page 1 ADDENDUM NUMBER 1 DATE: February 10, 2017 PROJECT: MSU Barnard Hall Room 105 Cleanroom Installation PPA# 16-0002 (Consulting Design Solutions, Inc. Project # 1613) BID DATE: February 23, 2017 2:00 PM,

More information

C0330, C0530, C0630, C0830, C1030 Service Parts

C0330, C0530, C0630, C0830, C1030 Service Parts This part list contains the service parts for the air cooled, water cooled and remote air cooled C00, C00, C00, C00, C00 ice machines. There was a change to panels and the C00 air cooled condenser in late

More information

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products Plumbing Plans Introduction Classifications of piping: Industrial Carries liquids and gases used in the manufacture of products Residential (i.e., plumbing) Carries fresh water, gas, liquid, solid waste

More information

Using the AcuDew Moisture Transmitter

Using the AcuDew Moisture Transmitter APPLICATION NOTE 2018_5-1 AcuDew Using the AcuDew Moisture Transmitter The AcuDew Transmitter is a two wire, 4-20 ma loop powered transmitter for continuous moisture measurement in process gases, glove

More information

Compressors, Chillers & Condensers

Compressors, Chillers & Condensers MARINE CONDENSER ACME MHX MARINE CONDENSER ACME Type MHX condensers are manufactured with the latest technology marine condenser tubing to provide compact size and cost effective use. STANDARD DESIGNS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Restrictor Orifice Coils These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly

More information

Basic Principles and Operation of Transformer

Basic Principles and Operation of Transformer Basic Principles and Operation of Transformer CONSTRUCTIONAL ASPECTS Cores In order to enhance core s magnetic properties, it is constructed from an iron and silicon mixture (alloy). The magnetic core

More information

Technical Information

Technical Information Date of last update: Aug-14 Ref: REFRIGERATION - CONTROLLING DIGITAL SCROLL Application Engineering Europe 1 Introduction Refrigeration applications such as retail and convenience stores are requesting

More information

Zone Control Unit (ZCU) VAV Turnkey Solution

Zone Control Unit (ZCU) VAV Turnkey Solution Description The Zone Control Unit (ZCU) is a VAV turnkey solution. It is an applied equipment-controls package that is pre-engineered and factory-fabricated, to dramatically reduce field installed equipment

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017 SECTION 23 0553 - MECHANICAL SYSTEMS IDENTIFICATION GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A/E REVIEW CHECKLIST HVAC

A/E REVIEW CHECKLIST HVAC A/E CHECKLIST HVAC Reviewers should - Use Checklists when reviewing any type of VA construction project for the following disciplines: Site and Landscape, Architectural, Structural, Plumbing, Fire Protection,

More information

CONDENSATE DRAIN PANS

CONDENSATE DRAIN PANS CONDENSATE DRAIN PANS TOTALINE CONDENSATE DRAIN PANS Totaline Condensate Drain Pans prevent harmful overflow moisture from reaching ceiling tiles, insulation or living space. Especially used in the attic

More information

Zone Control Unit (ZCU) Solution

Zone Control Unit (ZCU) Solution Description The Zone Control Unit (ZCU) is a VAV turnkey solution. It is an applied equipment-controls package that is preengineered and factory-fabricated, to dramatically reduce field installed equipment

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual T3111 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual Instruction manual for use of T3111 transmitters Transmitter

More information

MBC /602(L) MBC /602(L) MBC /602(L)

MBC /602(L) MBC /602(L) MBC /602(L) GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-... 1000/60(L) MBC-... 500/60(L) MBC-... 4000/60(L) Two normally closed automatic shutoff valves and servo regulator in one

More information

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe Markers. 2. Valve Tags. 3. Equipment Nameplates. 4. Underground Marking Tape. 5. Duct

More information

AHSC OWCB ARCHITECT ENGINEER. (Project) Submittal No. Description: Division: Section: Subcontract/Supplier:

AHSC OWCB ARCHITECT ENGINEER. (Project) Submittal No. Description: Division: Section: Subcontract/Supplier: O Neill Walsh Community Builders OWCB Submittal Form ARCHITECT ENGINEER Submittal No. Description: Date: Division: Section: AHSC (Project) Return By: Subcontract/Supplier: The review by O Neill Walsh Community

More information

Source 1. Replacement Parts

Source 1. Replacement Parts Source 1 Replacement Parts Supersedes : 035-19412-001-A-0303 BB 3 thru 5 Ton Single Package Heat Pump Standard-Efficiency 035-19412-001-B-0603 Note: This is a non-comprehensive parts list intended for

More information

PWM. Design, Installation, and Operation. (Pulse Width Modulation Zone Controller)

PWM. Design, Installation, and Operation. (Pulse Width Modulation Zone Controller) Small Duct Heating, Cooling and Indoor Air Quality Systems www.hi-velocity.com TM PWM (Pulse Width Modulation Zone Controller) Design, Installation, and Operation Includes: PWM Design PWM Installation

More information

TROUBLESHOOTING. KSIO MINI Split DC Inverter Air Conditioner. Model Numbers:

TROUBLESHOOTING. KSIO MINI Split DC Inverter Air Conditioner. Model Numbers: KSIO MINI Split DC Inverter Air Conditioner TROUBLESHOOTING Model Numbers: KSIO009-H24-I KSIO02-H23-I KSIO08-H22-I KSIO024-H29-I KWIO09-H2 KWIO2-H2 WARNING Installation MUST conform with local building

More information

Installation Instructions Student 101 Fume Cupboard

Installation Instructions Student 101 Fume Cupboard Installation Instructions Student 101 Fume Cupboard Refer drawing on next page 0. If your fume cupboard is supplied with a flatpack bench frame, see step1. If your fume cupboard will be mounted on an existing

More information

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK PART 1.0 GENERAL 1.1 SCOPE A. This specification contains the minimum requirements for the design, manufacture and testing of a UL listed,

More information

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet AEI800L Avid extreme Liquid Cooled Inverter Module REV 00, March 2016 Avid Controls Inc. 41261 Park 290 Drive, Waller, TX 77484, USA info@avidcontrolsinc.com (+1) (281) 640-8600 Page 1 of 16 Copyright

More information

Josefa Ortiz De Dominguez Elementary School 3000 S Lawndale Ave Chicago, IL 60623

Josefa Ortiz De Dominguez Elementary School 3000 S Lawndale Ave Chicago, IL 60623 3000 S Lawndale Ave Chicago, IL 023 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This

More information

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet For Mounting Heights To (environmental separation) STANDARD CONSTRUCTION 1/2 high x 13 1/2 deep 1/5 hp two speed motor(s) Factory installed fan speed/heat switch White or black powder coated exterior (Optional:

More information

BUILDING PLAN REVIEW REQUIREMENTS

BUILDING PLAN REVIEW REQUIREMENTS TOWNSHIP OF NORTH FAYETTE BUILDING DEPARTMENT COMMERCIAL PLAN REVIEW REQUIREMENTS BUILDING PLAN REVIEW REQUIREMENTS In order to perform a thorough Building Plan Review, the following specifications, drawings

More information

Description The aerodynamic shape of the Kongskilde blower ensures high efficiency and low energy consumption.

Description The aerodynamic shape of the Kongskilde blower ensures high efficiency and low energy consumption. Data sheet Blowers Kongskilde s FRL, FEA and TRL blowers constitute a range of proven conveying blowers, which are an ideal energy source for a vast number of industrial material handling systems. The

More information

OWNER S MANUAL #DC2V3 #DC2V3CF 1-1/2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2V Global Rd.

OWNER S MANUAL #DC2V3 #DC2V3CF 1-1/2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2V Global Rd. OWNER S MANUAL #DC2V3 #DC2V3CF 1-1/2 HP, 1500 CFM DUST COLLECTOR VERSION 1 -w/ 6 INLET PORT Model: #DC2V3CF 9900 Global Rd. Philadelphia, PA 19115 Model #DC2V3 Thank you for purchasing one of PSI s growing

More information

BLOWERS TRL /FRL/FEA

BLOWERS TRL /FRL/FEA BLOWERS TRL /FRL/FEA TRL/FEA/FRL Kongskilde s FRL, FEA and TRL blowers constitute a range of proven conveying blowers, which are an ideal energy source for a vast number of industrial material handling

More information

technical data air conditioning systems BS Units BSV4Q100P7V1

technical data air conditioning systems BS Units BSV4Q100P7V1 technical data BS Units BSV4Q00P7V air conditioning systems BS Units BSV4Q00P7V TABLE OF CONTENTS BSV4Q00P7V Specifications....................................................... 2 Technical Specifications.............................................

More information

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES

PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Assign unit identification numbers to operating units of equipment within a class or subclass during the design phase of new buildings, additions,

More information

Product Catalog. Split System ACDS-PRC003E-EN. Air-Cooled Condensers 20 to 120 Tons. April 2016

Product Catalog. Split System ACDS-PRC003E-EN. Air-Cooled Condensers 20 to 120 Tons. April 2016 Product Catalog Split System Air-Cooled Condensers 20 to 120 Tons April 2016 ACDS-PRC003E-EN Introduction Trane has the right condenser... If you are designing a new system or replacing an existing aircooled

More information

Copeland Digital Scroll

Copeland Digital Scroll Copeland Digital Scroll Technology & Advantages Presented by: Bruce Hilsabeck Application Engineer Copeland Australia / New Zealand Introduction 1. Scroll Compressor Basics 2. Digital Compressor Technology

More information

Click Here for Live Online Chat

Click Here for Live Online Chat Click Here for Live Online Chat Spare parts suitable for: TV Spare parts suitable for ice-cube machines electrical components solenoid valves for air-cooled machines 4 9090 bin thermostat Gala DP0-40,

More information

PARTS CATALOG R410A. No. OCB603 REVISED EDITION-A. March 2016 HFC SUZ-KA25VA5.TH-ET SUZ-KA35VA5.TH-ET SUZ-KA50VA5.TH-ET SUZ-KA60VA5.

PARTS CATALOG R410A. No. OCB603 REVISED EDITION-A. March 2016 HFC SUZ-KA25VA5.TH-ET SUZ-KA35VA5.TH-ET SUZ-KA50VA5.TH-ET SUZ-KA60VA5. SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PARTS CATALOG R410A [Model Name] SUZ-KA5VA5 SUZ-KA35VA5 SUZ-KA50VA5 SUZ-KA60VA5 SUZ-KA71VA5 [Service Ref.] SUZ-KA5VA5.TH SUZ-KA5VA5.TH-ET SUZ-KA35VA5.TH SUZ-KA35VA5.TH-ET

More information

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large Rolyan Splint Pan OPERATION MANUAL Item #081544816 - Small Item #081544808 Large PLEASE READ THIS ENTIRE MANUAL BEFORE OPERATING YOUR NEW SPLINT PAN. Failure to follow these instructions could result in

More information

PureAir. Oil-less Compressors

PureAir. Oil-less Compressors PureAir Oil-less Compressors 2 Oil-less Pure Air Series New Technology Creates New Applications With the perfection of oil-less air technology by Gardner Denver, new applications are being developed everyday:

More information

Thomas Chalmers Specialty Elementary School 2745 W Roosevelt Rd Chicago, IL 60608

Thomas Chalmers Specialty Elementary School 2745 W Roosevelt Rd Chicago, IL 60608 W Roosevelt Rd Chicago, IL 8 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report

More information

COMMERCIAL AIR CONDITIONERS M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N

COMMERCIAL AIR CONDITIONERS M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N COMMERCIAL AIR CONDITIONERS DIGITAL SCROLL SYSTEMS M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III WELCOME TO THE

More information

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND HVAC SYMBOL LEGEND HVAC PIPING AND VALVES LEGEND HVAC GENERAL NOTES SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION PHASING OF WORK HVAC ABBREVIATIONS ABBREVIATION

More information

Charles G Hammond Elementary School 2819 W 21st Pl Chicago, IL 60623

Charles G Hammond Elementary School 2819 W 21st Pl Chicago, IL 60623 Facility Assessment Report This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will roll-up each assessed item

More information

University of Chicago - North Kenwood/Oakland 1119 E 46th St Chicago, IL Co-locating on this campus are U OF C - NKO and ARIEL

University of Chicago - North Kenwood/Oakland 1119 E 46th St Chicago, IL Co-locating on this campus are U OF C - NKO and ARIEL Facility Assessment Report 9 E 4th St Chicago, IL 03 This report contains a summary of the results from the facility assessment completed on the date noted in the document footer below. This report will

More information

Blowers TRL/FRL/FEA. Number one in process waste handling. Blowers 50 Hz. Kongskilde

Blowers TRL/FRL/FEA. Number one in process waste handling. Blowers 50 Hz. Kongskilde Number one in process waste handling Blowers TRL/FRL/FEA Kongskilde Blowers 50 Hz Kongskilde s FRL, FEA and TRL blowers constitute a range of proven conveying blowers, which are an ideal energy source

More information

Repair Parts List REFRIGERATOR MODEL NUMBER JCD2290HEW. When requesting service or ordering parts, always provide the following information:

Repair Parts List REFRIGERATOR MODEL NUMBER JCD2290HEW. When requesting service or ordering parts, always provide the following information: Repair Parts List REFRIGERATOR MODEL NUMBER JCD2290HEW When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description

More information

RS /E-EV BLU SERIES

RS /E-EV BLU SERIES The RS/E and RS/EV series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above

More information

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial

More information

Multi Room MULTIELITE. Flexible and economical multi room comfort. That s better. That s Actron.

Multi Room MULTIELITE. Flexible and economical multi room comfort. That s better. That s Actron. Multi Room Flexible and economical multi room comfort. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become our

More information

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet For Mounting Heights To (environmental separation) STANDARD CONSTRUCTION 1/2 high x 13 1/2 deep 1/5 hp two speed motor(s) Factory installed fan speed/heat switch White or black powder coated exterior (Optional:

More information

Disney II Magnet School

Disney II Magnet School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

C O P E L A N D C R S E R I E S C O M P R E S S O R S Q U I E T E S T & E F F I C I E N T C O M P R E S S O R S I N T H E I R C L A S S

C O P E L A N D C R S E R I E S C O M P R E S S O R S Q U I E T E S T & E F F I C I E N T C O M P R E S S O R S I N T H E I R C L A S S C O P E L A N D C R S E R I E S C O M P R E S S O R S Q U I E T E S T & E F F I C I E N T C O M P R E S S O R S I N T H E I R C L A S S CONTENTS Page Product Description 1 Features & Performance Story

More information

SUZ-KA25VA3.TH SUZ-KA35VA3.TH SUZ-KA50VA3.TH SUZ-KA60VA3.TH SUZ-KA71VA3.TH

SUZ-KA25VA3.TH SUZ-KA35VA3.TH SUZ-KA50VA3.TH SUZ-KA60VA3.TH SUZ-KA71VA3.TH SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS February 013 No. OCB530 REVISED EDITION-A PARTS CATALOG R410A Outdoor unit [Model names] SUZ-KA5VA3 SUZ-KA35VA3 SUZ-KA50VA3 SUZ-KA60VA3 SUZ-KA71VA3 [Service Ref.]

More information

FORM EG3 (1201) YCWS WATER COOLED LIQUID CHILLER HFC-407C. 89 TONS THROUGH 209 TONS 313 kw THROUGH 735 kw 60Hz STYLE A

FORM EG3 (1201) YCWS WATER COOLED LIQUID CHILLER HFC-407C. 89 TONS THROUGH 209 TONS 313 kw THROUGH 735 kw 60Hz STYLE A FORM 201.24-EG3 (1201) YCWS WATER COOLED LIQUID CHILLER HFC-407C 89 TONS THROUGH 209 TONS 313 kw THROUGH 735 kw 60Hz STYLE A Table of Contents Introduction... 3 Specifications... 4 Accessories & Options...

More information

U of I Facilities Standards Updates for 2017

U of I Facilities Standards Updates for 2017 U of I Facilities Standards Updates for 2017 Updates to the U of I Facilities Standards will occur on a periodic basis (typically all standards will be reviewed for accuracy & completeness every 3 years),

More information

BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D

BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D HOSKINS ARCHITECTURE, LLC 1721 4 th AVENUE NORTH, SUITE 101 BIRMINGHAM, ALABAMA 35203 205.321.4122 ADDENDUM NO. 7 PROJECT: BIRMINGHAM CITY SCHOOLS (BCS) OPERATIONAL CENTER COMPLEX: BID PACKAGE D HOSKINS

More information

Repair Parts List REFRIGERATOR MODEL NUMBER ACD2234HRS. When requesting service or ordering parts, always provide the following information:

Repair Parts List REFRIGERATOR MODEL NUMBER ACD2234HRS. When requesting service or ordering parts, always provide the following information: Repair Parts List REFRIGERATOR MODEL NUMBER ACD2234HRS When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description

More information

CHABOT- LAS POSITAS COMMUNITY COLLEGE DISTRICT

CHABOT- LAS POSITAS COMMUNITY COLLEGE DISTRICT 1 CHABOT- LAS POSITAS COMMUNITY COLLEGE DISTRICT Facilities Planning & Management Department October 25, 2010 Addendum No. 09.R INVITATION FOR BID NO.: 11-05 Modernization of Classroom Building 300 Chabot

More information

Rufus M Hitch Elementary School

Rufus M Hitch Elementary School Facility Assessment Summary This report summarizes the findings of a facility assessment completed on the date noted in the document footer below. Assessors rate each facility feature and system by visual

More information

RUND Decorative Column

RUND Decorative Column RUND Air Curtain RUND Decorative Column Decorative air curtain RUND, cylindrical in shape, is ideal for entrances and buildings where class, elegance and majesty is required. Vertically installed on one

More information

Air Conditioning. Technical Data. Floor standing unit EEDEN FXLQ-P

Air Conditioning. Technical Data. Floor standing unit EEDEN FXLQ-P Air Conditioning Technical Data Floor standing unit EEDEN15-204 FXLQ-P Indoor Unit FXLQ-P TABLE OF CONTENTS FXLQ-P 1 Features............................................................. 2 2 Specifications.......................................................

More information

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on triac output and electric reheater

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on triac output and electric reheater Heating with LHW and cooling with CHW changeover Modulating control of heating and cooling valve (2 pipe) on triac Automatic or manual 3-speed fan control Room temperature and fan speed operation via KNX

More information