COMMERCIAL AIR CONDITIONERS M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N
|
|
- Silvia Pearson
- 5 years ago
- Views:
Transcription
1 COMMERCIAL AIR CONDITIONERS DIGITAL SCROLL SYSTEMS M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N
2 C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III WELCOME TO THE WORLD OF SINCLAIR AIR CONDITIONERS Company operation and procedures comply with ISO SINCLAIR products comply with European standards, which guarantee safe operation.
3 M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N SINCLAIR represents high standard of quality, great performance with modern design. SINCLAIR SDV III commercial system provides complex solution for air conditioning of entire buildings. Wide range of capacities and models of indoor units enable countless combinations which will meet any of your needs. SDV III model line uses only environmentally friendly, CFC free refrigerant R-410A which prevents ozone layer depletion by CFCs. This refrigerant also improves energy effi ciency.
4 C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III PRODUCT EXPLODED VIEW SMALLER PRESSURE LOSS, LOWER NOISE The grill of fan air inlet and fan air outlet have airfl ow direction adjusting function, which leads to lower pressure loss. BIGGER AIRFLOW VOLUME, LOWER NOISE Adopt dual turbofan which make bigger airfl ow volume with lower noise. RELIABLE ELECTRIC CONTROL PCB Benefi t from digital scroll compressor, no need to apply complex inverter module to achieve variable capacity output. More simple and reliable, no electromagnetic interference. NEW TYPE HIGH EFFICIENT HEAT EXCHANGER Adopt 3-row inner-screw copper heat-exchanger, which creates higher heat transfer effi ciency and powerful heating capacity especially in low ambient temperature. PATENTED DESIGN, RUNNING RELIABLE Gas balance: balancing the refrigerant suction volume among different compressors. 4
5 M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N ELEGANT APPEARANCE, LONGEVITY OF USAGE Achieving advanced technical process, which gets elegant appearance with longevity of usage. CREATIVE DESIGN, PRECISE REFRIGERANT CONTROL Double electrical expansion valve, which achieves up to 960 steps refrigerant adjusting precision to get the best refrigerant distribution effect. CLASSIC DESING, PRECISELY CONTROL HEAT-EXCHANGER AREA The area of outdoor heat-exchanger can be precisely adjusted. POWERFUL REFRIGERANT SYSTEM CONFIGURATION ADOPT DIGITAL SCROLL COMPRESSOR. Compressor with wide running arrangement, multi compressors can be parallely connected, the corresponding capacity range can achieve 2.5%-100% (when 4 models assembled to 64 HP) RESERVING SPECIAL-DESINGED TRANSPORTATION POSITION FOR FORKLIFT Making easy installation for the sling movement. 5
6 C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III FULL RANGE OF R410A DIGITAL SCROLL A/C SYSTEM FEATURE OF R410A SYSTEM Friendly Refrigerant, save energy and protect environment. Good performance of cooling and heating. The component of the R410A is close to azeotropy, with little change of the component structure, the capability will not decrease during the recharge period. Does not contain the element Chlorine, protects the ozonosphere. R410A BASIC MODULES 5 basic modules: 8HP, 10HP, 12HP, 14HP, 16HP 2HP increments of capacity HIGH EFFICIENCY, THE EER IS UP TO 3.45 Basic modules FREE COMBINATION, WIDE RANGE 5 basic modules, which can be freely assembled. 2HP increments of capacity range, which meets customers needs accurately. Maximum capacity is 64HP HP HP HP 8-16 HP 6
7 M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N INTELLIGENT BUILT-IN MANAGER SYSTEM Intelligent Manager is an integrated building management system (BMS) that uses our independent, high-speed multi-transmission method. It has a centralized controller function that can perform high-speed centralized control of our commercial A/C for buildings. SDV III SYSTEM HAS VARIOUS CONTROL SOLUTIONS: Individual control, Group control, Network control, etc. 1 computer can monitor max 16 central controllers. 1 central controller can monitor max 64 indoor units. 1 computer can monitor max 1024 indoor units. BMS *Elevator *Pump *Lighting...etc. Fire alarm Security Power supply facility R LON bus over ethernet Max=32 Lonwork Max=64 Built-in manager system Max= 16 Max=64 Touch controller Central controller Remote controller 7
8 C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III INTELLIGENT BUILT-IN MANAGER SYSTEM INDEPENDENT CALCULATING SYSTEM POWER POWER POWER CCM Max=64 CCM Converter POWER Digital Ammeter Built-in manager system INDEPENDENT CALCULATION REPORT Independent calculation and output with report, easy to know the charge of the A/C. GROUP SETTING, SIMPLE AND EFFICIENT One group consists of on-line A/Cs in different Central controllers, maximum 1024 units. One system can be set by 16 groups to manage a huge A/C system. The group setting can control each on-line unit, unionize them to be On / Off or change the parameters. It s so convenient and easy. SCHEDULE SETTING, NO NEED TO WORRY DURING THE OPERATION OF A/C With the advanced Schedule setting mode, the PC can easily manage the daily work of A/C. The system can set the weekly plan of A/C and operate automatically in cycle. 8
9 M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N MODEL SELECTION SOFTWARE WINDOWS VERSION Operate directly on Windows interface Friendlier itnerface makes its applicable range much wider. Main functions includes load calculation, multisplit and chilled water system selection, explicit quotation table output, hydraulic calculation, capacity inquire with changeable outdoor environment (for multi-split) or nonstandard working criteria (for chiller), etc. Update with product change. SDV III CAD VERSION The version is compatible with AutoCAD 2004/2005. Professional software that helps engineers design project easily, quickly and conveniently. Main functions include load calculation, equipment selection, pipeline setting, system fi gure confi guration, quotation table automatic output, refrigerant volume calculation, wiring and installation diagram output, etc. Update with product change. 9
10 C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III FEATURES OF DIGITAL SCROLL COMPRESSOR COPELAND Extended energy adjustment range: 10% - 100%. Real stepless energy adjustment. Long life-time: PWM solenoid valve can be used 40 billion times on average, which is equal to 30 years life. High effi ciency and stability of the refrigerant compressed by applying the axial compliant sealing technology. Illustration of real scroll compressor cross-section of unit Operation principle of digital scroll compressor PWM Valve Discharge Fixed Scroll Suction Orbiting Scroll DIGITAL SCROLL COMPRESSOR COPELAND 10
11 M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N OPERATION PRINCIPLE OF DIGITAL SCROLL COMPRESSOR Biasing chamber Discharge pressure Single 2-way solenoid valve (open) Bleed hole The digital scroll compressor which utilizes the axial compliant sealing technology precisely adjusts the axial moving range of the stator scroll pan. And there is an additional connecting bypass between the suction inlet and the pressure bore at the fl oating sealing point of axial stator. When PWM solenoid valve is open, the pressure in the pressure bore is released. The pressure in the compression bore is higher than that top of the stator, then the stator axis of the compressor will move upward a little. So high pressure bore and low pressure inlet is connected and the unloading is achieved. When PWM solenoid valve is closed, two stators are engage. Then the airproof and loading is achieved. The compressor can adjust the ratio of ONs to OFFs freely to control the refrigerant output from the compressor. Biasing chamber UNLOADING Discharge pressure Suction pressure Single 2-way solenoid valve (closed) Bleed hole Suction pressure LOADING CONTROL PRINCIPLE OF VARIABLE CAPACITY SYSTEM Periodical load and unload of the compressor can control refrigerant volume. One unloading and one loading are called one control cycle. Generally one control cycle takes 10 to 20 seconds. The control of the ratio of the unloading and loading time can achieve different output of refrigerant. THE SCHEMATIC DIAGRAMS OF 10%, 50% AND 100% OF THE FULL CAPACITY Example: suppose full capacity is 10HP, and control cycle is 20 seconds. If output needs 5HP (50% of the full capacity), then loading time account for 50% of the total time. That is, 10 seconds respectively for both loading time and unioading time. If you need to output 2HP (20% of the full capacity), then the load time will take up 20% of the total time, that is, 4 seconds for loading and 16 seconds for unioading. This formula applies to other numbers. 100% Output capacity 50% Output capacity 10% Output capacity 20 second cycles 20 second cycle 20 second cycle 11
12 C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III OUTDOOR UNIT Capacity (HP) Model Combination (HP) Indoor unit 4 SDV-120EA SDV-140EA SDV-252EA SDV-280EA SDV-335EA SDV-400EA SDV-450EA SDV-532EA SDV-560EA SDV-615EA SDV-680EA SDV-730EA SDV-785EA SDV-850EA SDV-900EA SDV-960EA 10x SDV-1010EA 10x SDV-1065EA SDV-1130EA SDV-1180EA 10+16x SDV-1235EA 12+16x SDV-1300EA 14+16x SDV-1350EA 16x SDV-1405EA 12x SDV-1455EA 12x SDV-1520EA 12x SDV-1570EA 12x2+16x SDV-1630EA 10+16x SDV-1685EA 12+16x SDV-1750EA 14+16x SDV-1800EA 16x4 64 Model SDV- 120EA 140EA 252EA 280EA 335EA 400EA 450EA Capacity Cooling kw , , Heating kw , Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance , 50, , 50, 3 Air Flow Volume m Noise Level db(a) Dimension Net W H D mm 940x1245x x1245x x1630x x1630x830 Packing W H D mm 1058x1300x x1300x x1780x x1800x860 Weight Net kg Gross kg Piping Connection Max Lenght of pipe Max Height Difference Between indoor units Between indoor units and outdoor unit Remarks: 1. The above speciffi cations are subject to change without prior notice for product improvement. 2. The noise levels given in the table refl ect the levels in anechoic chamber. 3. SDV-120EA and SDV-140EA are not modular. 12
13 M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N INDOOR UNIT FOUR-WAY CASSETTE COMPACT Model SDV- 28CA 36CA 45CA Capacity Cooling kw 2,8 3,6 4,5 Heating kw 3,2 4 5 Electrical Data Voltage, Frequence, Phase V~, Hz, f ,50,1 Performance Air Flow Volume m Noise Level db(a) 36 Dimension Net W H D mm 580x254x580 Panel W H D mm 650x30x650 Packing W H D mm 795x340x745 Panel W H D mm 715x115x715 Weight Net kg 22/3 Gross kg 29/5 FOUR-WAY CASSETTE Model SDV- 54C4A 71C4A 80C4A 90C4A 112C4A Capacity Cooling kw 5,6 7, ,2 Heating kw 6, ,5 Electrical Data Voltage, Frequence, Phase V~, Hz, f ,50,1 Performance Air Flow Volume m Noise Level db(a) Dimension Net W H D mm 840x240x x310x840 Panel W H D mm 950x40x950 Packing W H D mm 955x255x x325x955 Panel W H D mm 1030x145x1030 Weight Net kg 28/6 35/6 Gross kg 34/11 41/11 DUCT Model SDV- 22DA 28DA 36DA 45DA 56DA 71DA 80DA 90DA 112DA 140DA Capacity Cooling kw 2,2 2,8 3,6 4,5 5,6 7, ,2 14 Heating kw 2,6 3, , ,5 16 Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance ,50,1 Air Flow Volume m External static pressure 40 Noise Level db(a) Dimension Net W H D mm 800x320x x298x x298x800 Packing W H D mm 930x420x x370x x370x930 Weight Net kg Gross kg
14 C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III INDOOR UNIT FLOOR STANDING Model SDV- 22FSA 28FSA 36FSA 45FSA 56FSA 71FSA 80FSA Capacity Cooling kw 2,2 2,8 3,6 4,5 5,6 7,1 8 Heating kw 2,6 3, ,3 8 9 Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance ,50,1 Air Flow Volume m Noise Level db(a) Dimension Net W H D mm 1000x626x x626x x626x220 Packing W H D mm 1145x810x x810x x810x285 Weight Net kg Gross kg CEILING & FLOOR Model SDV- 36FA 45FA 56FA 71FA 80FA 90FA 112FA Capacity Cooling kw 3,6 4,5 5,6 7, ,2 Heating kw 4 5 6, ,5 Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance ,50,1 Air Flow Volume m Noise Level db(a) Dimension Net W H D mm 995x660x x660x x680x240 Packing W H D mm 1080x740x x740x x760x330 Weight Net kg Gross kg WALL-MOUNTED Model SDV 22HA 28HA 36HA 45HA 56HA Capacity Cooling kw 2,2 2,8 3,6 4,5 5,6 Heating kw 2,5 3, ,3 Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance ,50,1 Air Flow Volume m Noise Level db(a) Dimension Net W H D mm 790x265x x292x225 Packing W H D mm 875x375x x368x295 Weight Net kg 9 13 Gross kg
15 M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N CONTROLLERS DESCRIPTION Remote Controller (Standard) Wire Controller (Optional) Wire Controller (Optional) Central Control Monitor (Optional) Central Control Monitor (Optional) Touch Controller (Optional) R51, R05/BG KJR-01B KJR-10B, KJR-12B CCM04 Suitable for SDV III system Suitable for SDV III system KJR-10B New design KJR-12B New design with function FOLLOW ME CCM04 Weekly timer MODEL CCM01 FUNCTION Control 64 indoor units simultaneously at most (suitable for SDV III system) CCM02 CCM10 CCM02 Control 32 outdoor units simultaneously at most (suitable for SDV III system). CCM10 New design with lock heating or cooling. TCM01 Suitable for Intelligent built-in manager system SET BUTTON Enter into the setting screen. MODE BUTTON Choose the mode. CENTRAL CONTROLLER QUERY BUTTON Check the running status of the A/C. TIMER BUTTON Set the current time and off time. SWING BUTTON With or without swing. OK BUTTON Confirm the operation. OPERATION INDICATOR Lights when the unit is in operation. ON/OFF BUTTON Start or stop operation. FAN SPEED BUTTON Adjust fan speed. PREVIOUS OR NEXT BUTTON In query or set mode, Transfer between previous and next unit. DATAS OR PAGES ADJUST BUTTON Adjust the datas or pages. RESET BUTTON Reset current unit to the default setting. LOCK BUTTON Lock or unlock current A/C status. AUXILIARY HEATER BUTTON Start or sto p the electrical auxiliary heater ON/OFF BUTTON Start or stop operation. WIRE CONTROLLER FOLLOW ME BUTTON Adjust the action of indoor unit according to the Temp. sensor inside the wire controller TIMER BUTTON Timer setting. OK BUTTON Confirm the operation RESET BUTTON Reset all the setting and get in to the condition of beginning. MODE BUTTON Choose the mode. ECONOMY BUTTON Start or stop economical mode TEMP. BUTTON Preset temperature. SWING BUTTON With or without swing. FAN SPEED BUTTON Choose fan speed. LOCK BUTTON Lock or unlock all current setting. 15
16 C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III DISTRIBUTOR REFRIGERANT DISTRIBUTOR DIMENSION CHART The connecting point can be freely adjusted to meet different pipes. Adoption of international standard measurement assures easy replacement. SDV-BY51N1 Gas side SDV-BY101N1 Gas side Liquid side Liquid side SDV-BY102A Gas side SDV-BY103A Gas side Liquid side Liquid side 16
17 M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N SDV-BY104 Gas side SDV-BY105 Gas side Liquid side Liquid side THE DIMENSION OF Y-SHAPE THREE-WAY PIPE. SDV-DY01 Gas side SDV-DY02 Gas side Liquid side Liquid side 17
18 C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III SEE YOU IN THE WORLD OF AIR CONDITIONERS
19 M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N AIR CONDITIONERS represent a modern, reliable and effective solution how to create a pleasant conditions for satisfi ed living of people.
20 Internet: COMMERCIAL AIR CONDITIONERS
Technical Information
Date of last update: Aug-14 Ref: REFRIGERATION - CONTROLLING DIGITAL SCROLL Application Engineering Europe 1 Introduction Refrigeration applications such as retail and convenience stores are requesting
More informationSPLIT DUCTED UNIT TECHNICAL SELECTION DATA SRA141C / SRA140E SPECIFICATION SUMMARY UNIT FEATURES CONTROL FEATURES CONTROL OPTIONS. PLENUMS (Optional)
TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 1 SINGLE PHASE SCROLL SINGLE STAGE SS M SOFT START CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Single Phase Soft Starter
More informationProduct Launch Package. Refrigeration Marketing Units Emerson Climate Technologies Europe
Digital Receiver Unit - HLR Product Launch Package Refrigeration Marketing Units Emerson Climate Technologies Europe Emerson Climate Technologies Existing Digital Range Application Outdoor Installations,
More informationCOMPACT CASSETTE TYPE AIR CONDITIONER
COMPACT CASSETTE TYPE AIR CONDITIONER TECHNICAL MANUAL CONTENTS 1.FEATURE... 1 2.OUTLINE AND DIMENSIONS... 2.1 INDOOR UNIT... 2.2 OUTDOOR UNIT... 4.DATA....1 PERFORMANCE CURVE....2 TEMPERATURE RANGE....
More informationCopeland Digital Scroll
Copeland Digital Scroll Technology & Advantages Presented by: Bruce Hilsabeck Application Engineer Copeland Australia / New Zealand Introduction 1. Scroll Compressor Basics 2. Digital Compressor Technology
More informationVAV Rectangular Terminal Units
RSVQ VAV Rectangular Terminal Units RSVQ Variable Air Volume (VAV) HVAC systems are the best solution to guarantee high levels of comfort and energy effi ciency in civil and industrial applications VAV
More information4 T V H A D A A
4 T V H 0 0 8 6 A D 0 0 0 A A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Name All of units Outline Function Outdoor unit installation manual 1 Outdoor unit user manual 1 Be sure to deliver it to the customer
More informationMulti Room MULTIELITE. Flexible and economical multi room comfort. That s better. That s Actron.
Multi Room Flexible and economical multi room comfort. That s better. That s Actron. ActronAir. Because Australia needs Australian air conditioning. The year 1984 saw Advanced Australia Fair become our
More informationRUND Decorative Column
RUND Air Curtain RUND Decorative Column Decorative air curtain RUND, cylindrical in shape, is ideal for entrances and buildings where class, elegance and majesty is required. Vertically installed on one
More information- Clamshell - OD-Mounted Pipe Cutting and Beveling Machine. Split frame. cutting and beveling simultaneously
Split frame OD-Mounted Pipe Cutting and Beveling Machine The series machine is ideal for all types of pipe cutting, beveling and end preparation. The split frame design allows the machine to split in half
More informationPRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature
PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature Temperature control: Feel good at any time of year Room thermostats Heating time switches Excellent products
More informationHoneywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER
Honeywell RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER W7620 Zone Controller Water Source Heat Pump - -.> The W7620 Zone Controller provides customized control of HVAC zone equipment.
More informationPower Proportional Distribution (PPD)
AN-PPD-11-18 Power Proportional Distribution (PPD) Application Note Table of Contents 1. Description... 3 2. Application and Design... 3 2.1 PPD Application with an intelligent Touch Controller (itc)...
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR OUTDOOR 1. INDOOR UNIT : DTR_AR060E_03 2013.11.08 1. INDOOR UNIT CONTENTS 1. FEATURES... 01-01 2. WIRED REMOTE CONTROLLER... 01-04 3. SPECIFICATIONS...
More informationGEA Screw Packages. Plug & play compressor units for industrial refrigeration and air conditioning
GEA Screw Packages Plug & play compressor units for industrial refrigeration and air conditioning 2 3 Top quality based on proven development Whether it s in the food industry, chemical industry, in offices
More informationAIR COOLED CONDENSERS with EC AXIAL FANS
AIR COOLED CONDENSERS with EC AXIAL FANS SELECTION GUIDE 2 TABLE OF CONTENTS EC Fan Remote Outdoor Type Model GHRC...4 Model Identifi cation...4 Condenser Selection Chart...5 Condenser Capacities...6 Condenser
More informationCNC Machining Center BAZ 895n IQ
CNC Machining Center BAZ 895n IQ * Due to the continuous improvements of our products, some machine changes may apply. Features Use of SYNTEC control system, fully automatic production from labeling, loading,
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationGUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION
GUIDE SPECIFICATIONS 256920-UGS-A-0506 Simplicity Intelli-Comfort Optional Control in 3-25 Ton Packaged Units GENERAL DESCRIPTION CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP Equipment with Simplicity
More informationPRESS RELEASE. Let s create your success! with GEA at Chillventa 2016
Let s create your success! with GEA at Chillventa 2016 Düsseldorf (Germany), August 31, 2016 From October 11 to 13, 2016, Chillventa will turn the trade show fairgrounds in Nuremberg into an international
More informationCode. Edition 04/2013. CPA Screw Air Compressors. Parts List Book
Code 2205 1084 06 Edition 04/2013 CPA7.5-10-15-20 Screw Air Compressors Parts List Book REF. PART NUM. QTY. NAME REF. PART NUM. QTY. NAME 1095 2205 1020 83 1 BASE 1195 2205 1053 83 1 PANEL 1100 2205 1028
More information2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type
PAGE 2 of 6 2.14 Main Cable Type HO7RN-F4G10-15 Metres each 2.15 (a) O/P Voltage-350V(Max.) (b) O/P Current 150A(Max.) 2.16 Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type 2.17
More informationCommunicative heating controller
UC100 Communicative heating controller Summary UC100 is a communicative room heating controller with one PWM output for control of a radiator or electrical heater. It can work autonomously, or in connection
More informationICARUS ELECTRONIC GAS VOLUME CONVERTER
ICARUS ELECTRONIC GAS VOLUME CONVERTER 1. INTRODUCTION 2. TECHNICAL DETAILS ICARUS is an electronic volume converter which, combined with a gas meter, provides the gas measurement in Sm3, calculated at
More informationPARTS CATALOG R410A. September 2008 AIR TO WATER HEAT PUMP. No. OCB439 REVISED EDITION-A. [Service Ref.] [model name]
AIR TO WATER HEAT PUMP PARTS CATALOG R40A [model name] PUHZ-W50VHA PUHZ-W5VHA PUHZ-HWYHA PUHZ-HW40VHA PUHZ-HW40YHA [Service Ref.] PUHZ-W50VHA PUHZ-W5VHA PUHZ-HWYHA PUHZ-HW40VHA PUHZ-HW40YHA September 00
More informationBenchtop Incubator Shakers
www.zhichenginstrument.com Benchtop Incubator Shakers Models: ZHWY-200B ZHWY-100B ZHWY-200D ZHWY-100D ZHWY-100C ZHICHENG benchtop incubator shakers offer small capacity growth of biological organisms under
More informationTechnical Supplies & Services Co. L.L.C.
Technical Supplies & Services Co. L.L.C. An Overview In TSSC, every SS Refrigerator and Freezer is manufactured with utmost care to meet the highest quality standards and customer specifications. With
More informationADDENDUM NO. 4 November 15, Page 1
ADDENDUM NO. 4 November 15, 201 8 Page 1 PROJECT MANUAL FOR CONSTRUCTION OF HVAC REPLACEMENT FOR NORTH OCONEE HIGH SCHOOL FOR OCONEE COUNTY SCHOOLS WATKINSVILLE, GEORGIA DATED: SEPTEMBER 14, 2018 CUNNINGHAM,
More information13acd MERIT SERIES R 22 A I R C O N D I T I O N E R S. SEER up to to 5 Tons Cooling Capacity 17,500 to 60,000 Btuh
E N G I N E E R I N G D A T A A I R C O N D I T I O N E R S 13acd MERIT SERIES R 22 Bulletin No. 210423 April 2008 Supersedes January 2008 SEER up to 14.0 1.5 to 5 Tons Cooling Capacity 17,500 to 60,000
More informationRS /E-EV BLU SERIES
The RS/E and RS/EV series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above
More informationDigital Room Sensor Technical Guide
www.orioncontrols.com Digital Room Sensor Technical Guide TABLE OF CONTENTS OVERVIEW... 3 BASIC OPERATION... 4 Sensor Operation... 4 LED Operation... 4 MOUNTING AND WIRING... 5 Environmental Requirements...
More informationSUPER INVERTER SERIES MULTI TYPE. Service Manual 2018
SUPER INVERTER SERIES MULTI TYPE Service Manual 2018 CONTENTS 1. General information of Indoor Units... 1 2. Features... 2 3. Dimensions... 12 4. Service Space (unit: mm)... 20 5. Wiring diagram... 23
More informationPARTS CATALOG R410A. No. OCB603 REVISED EDITION-A. March 2016 HFC SUZ-KA25VA5.TH-ET SUZ-KA35VA5.TH-ET SUZ-KA50VA5.TH-ET SUZ-KA60VA5.
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PARTS CATALOG R410A [Model Name] SUZ-KA5VA5 SUZ-KA35VA5 SUZ-KA50VA5 SUZ-KA60VA5 SUZ-KA71VA5 [Service Ref.] SUZ-KA5VA5.TH SUZ-KA5VA5.TH-ET SUZ-KA35VA5.TH SUZ-KA35VA5.TH-ET
More informationCONTROL MANUAL. Dry-Pic 09PE - 09VE
CONTROL MANUAL Dry-Pic 09PE - 09VE Translation of the original document 003, 04.01 EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth
More informationSONOMETER TM 1100 Ultrasonic compact energy meter
Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter
More informationRS /M MZ SERIES
The RS 310-410-510-610/M MZ burners series covers a firing range from 1300 to 6300 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic
More informationSONOMETER TM 1100 Ultrasonic compact energy meter
Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter
More informationWeeke Machining Center, Model BP-100 Optimat
This PDF file has not been verified for accuracy. BEFORE BIDDING, all bidders should use the inspection period to verify specifications. Weeke Machining Center, Model BP-100 Optimat Weeke's BP-100 is a
More informationTPV 1200 BTB. Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 160 / 0516 / E
HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415
More informationTSE. Turbomiser. Condenserless water chiller with centrifugal compressors to be connected with a remote. for indoor installation
TECHNICAL Data Sheet TSE Condenserless water chiller with centrifugal compressors to be connected with a remote condenser (RCE) for indoor installation Turbomiser TSE Range 200-2.400 kw TSE Range Condenserless
More informationINSTALLATION MANUAL. Address card EKAC200A
INSTALLATION MANUAL Address card 4 1 3 1 2 + GND TX+ TX- 3 29 mm 60 mm 20 mm 2 4 READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO NOT THROW IT AWAY. KEEP IT IN YOUR FILES FOR FUTURE REFERENCE.
More informationGV60 PLUS. GV60 PLUS Electronic Ignition Remote Control. used on Valor heaters of Series Portrait, Horizon, H4, G3, L1, L2, L3, MF and RFD
OPERATION MANUAL GV60 PLUS GV60 PLUS Electronic Ignition Remote Control used on Valor heaters of Series Portrait, Horizon, H4, G3, L1, L2, L3, MF and RFD For Valor heaters 530, 534, 650, 739, 1500, 1600,
More informationDigital flow ELEMENT transmitter for continuous flow measurement
Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single
More informationVX-3000 Series Voice Alarm and Public Address System
VX-3000 Series Voice Alarm and Public Address System VX-3000 SERIES Combined highly integrated voice alarm and public address system. The issue of security is more than ever important. Our VX-3000 is a
More informationSUZ-KA25VA3.TH SUZ-KA35VA3.TH SUZ-KA50VA3.TH SUZ-KA60VA3.TH SUZ-KA71VA3.TH
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS October 202 PARTS CATALOG R40A Outdoor unit [Model names] SUZ-KA25VA3 SUZ-KA35VA3 SUZ-KA50VA3 SUZ-KA60VA3 SUZ-KA7VA3 [Service Ref.] SUZ-KA25VA3.TH SUZ-KA50VA3.TH
More informationIntegrations GW Programming manual
Integrations GW632200 Programming manual Index 1 General description 2 2 Technical information 3 3 Programming 4 3.1 Application program information 4 3.2 Individual address assignment 5 3.3 Communication
More informationWeeke CNC Machining Center, Model BP-140 K ATC Optimat
Weeke CNC Machining Center, Model BP-140 K ATC Optimat Weeke's BP-140 is a truly industrial machine designed primarily for pointto-point boring and machining of flat components without special workpiece
More informationPhysical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free
Physical Properties Measurement System (PPMS): A Cryogen-free Physical Properties Measurement system that operates over a wider range of temperature and magnetic fields: fully automated/computer controlled
More informationSUZ-KA25VA3.TH SUZ-KA35VA3.TH SUZ-KA50VA3.TH SUZ-KA60VA3.TH SUZ-KA71VA3.TH
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS February 013 No. OCB530 REVISED EDITION-A PARTS CATALOG R410A Outdoor unit [Model names] SUZ-KA5VA3 SUZ-KA35VA3 SUZ-KA50VA3 SUZ-KA60VA3 SUZ-KA71VA3 [Service Ref.]
More informationIntesisBox DK-AC-ENO-1C
IntesisBox DK-AC-ENO-1 DK-AC-ENO-1C v.1.0.12 v.1.0.12 EnOcean Interface for Daikin air conditioners. Compatible with Domestic lines User's Manual v1 r6 eng Reference: DK-AC-ENO-1 / 1C Issue Date: 02/2012
More informationChillers for the industrial refrigeration and air conditioning
GEA Grasso chillers Chillers for the industrial refrigeration and air conditioning engineering for a better world GEA Refrigeration Technologies Whether it s in the food industry, chemical industry, in
More informationDigital flow ELEMENT transmitter for continuous flow measurement
ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationTECHNICAL SUPPORT MANUAL Fan Coils FXM4X
Fan Coils FXM4X DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product
More informationWeeke CNC Machining Center, Model BHC 350 4/10 Optimat
Technical Specification March 11, 2004 Page 1 Weeke CNC Machining Center, Model BHC 350 4/10 Optimat Weeke's BHC 350 4/10 Optimat is a flexible CNC machining center designed primarily for routing, boring,
More informationOutdoor units. Specifications
9 Outdoor units Specifications 9-1. Capacity correction... 156 9-2. Electrical wiring diagram... 163 9-3. Sound pressure level... 167 9-4. Cycle diagram... 172 9-5. Dimensional drawing... 173 1 9-3. Sound
More informationCommercial Refrigeration Price List
Commercial Refrigeration Price List KPL3_004_073118 Effective Date: August 1, 2018 Krack Commercial Refrigeration Price Lists are updated quarterly; January, April, July and October; and posted on our
More informationViconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification
Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification General The VT76x7 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationAEROCONNECT 1B NA C Control manual
AEROCONNECT 1B NA 11.3 C 03-01 Control manual EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth 1. Sensor connections 1.6 Communication
More informationCELES MP Flexible - Compact - High Efficiency. Induction Heating - Power from 2 to 12 kw - Frequency from 20 khz to 2 MHz.
CELES MP 2-12 Induction Heating - Power from 2 to 12 kw - Frequency from 20 khz to 2 MHz - Flexible - Compact - High Efficiency - Solid state design - Maximum power over a large impedance range - Wide
More informationTangential Fans - Basic principles. Expertise, performance, innovation
Tangential Fans - Basic principles Expertise, performance, innovation Fans 1 Stove jacket cooling, storage heaters, wood-burning stoves, underfloor convectors, tanning beds, air conditioners and heaters
More informationUSE OF INVERTERS WITH COPELAND STREAM COMPRESSORS
Date of last update: Nov-1 Ref: D7.9.3/0613-111/E Application Engineering Europe USE OF INVERTERS WITH COPELAND STREAM COMPRESSORS 1 Introduction Inverters are used to vary the speed of motors and in this
More informationIntroduction to BAS Technology
Introduction to BAS Technology Dave Kahn, P.E. Why Back to basics? Sometimes you get what you ask for resulting in: The perfect job OR Unhappy owners & occupants Unexpected network limitations Product
More informationTROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN
TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller Mounting and Operating Instructions EB 5578 EN Firmware version 2.2x Edition May 2015 Definition of signal words DANGER!
More informationPureAir. Oil-less Compressors
PureAir Oil-less Compressors 2 Oil-less Pure Air Series New Technology Creates New Applications With the perfection of oil-less air technology by Gardner Denver, new applications are being developed everyday:
More informationGEA Grasso screw packages. The full range of GEA Grasso screw packages. engineering for a better world. GEA Refrigeration Technologies
GEA Grasso screw packages The full range of GEA Grasso screw packages engineering for a better world GEA Refrigeration Technologies Whether it s in the food industry, chemical industry, in offices or in
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationPARTS CATALOG R410A. January 2012 PUHZ-HW112YHA PUHZ-HW112YHA-BS PUHZ-HW140VHA PUHZ-HW140VHA-BS PUHZ-HW140YHA PUHZ-HW140YHA-BS PUHZ-HW140VHA2R2-BS
AIR TO WATER HEAT PUMP PARTS CATALOG [Model name] PUHZ-W50VHA PUHZ-W50VHA-BS PUHZ-W85VHA PUHZ-W85VHA-BS PUHZ-HWYHA PUHZ-HWYHA-BS PUHZ-HWYHA PUHZ-HWYHA-BS PUHZ-HW0VHA PUHZ-HW0VHA-BS PUHZ-HW0YHA PUHZ-HW0YHA-BS
More informationSelf-learning Room Temperature Controller Receiver
2 265 REV23RF REV-R.02/1 REV23RF/SE Self-learning Room emperature Controller Receiver Consisting of controller (with integrated radio transmitter) and receiver (switching unit with relay outputs) REV23RF
More informationControl solutions Biofloor
MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital
More informationSatellite Testing. Prepared by. A.Kaviyarasu Assistant Professor Department of Aerospace Engineering Madras Institute Of Technology Chromepet, Chennai
Satellite Testing Prepared by A.Kaviyarasu Assistant Professor Department of Aerospace Engineering Madras Institute Of Technology Chromepet, Chennai @copyright Solar Panel Deployment Test Spacecraft operating
More informationMODUBLOC MB SE SERIES
The MODUBLOC MB SE series of burners are characterised by a monoblock structure that means all necessary components can be combined in a single unit, making installation easier and faster. The series covers
More informationReciprocating compressors for industrial refrigeration
GEA Grasso V Series Reciprocating compressors for industrial refrigeration engineering for a better world GEA Refrigeration Technologies GEA Refrigeration Technologies, part of the internationally active
More informationTROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN
TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller Mounting and Operating Instructions EB 5578 EN Firmware version 2.30 Edition November 2017 Definition of signal words DANGER!
More informationFD 125 Large-Format Card Cutter
FD 125 Large-Format Card Cutter 3/201 OPERATOR MANUAL Page 2 Table of Contents SAFETY PRECAUTIONS... 4 Introduction... 5 Specifications... 5 Accessories... 5 Major Components and Assemblies... 6 Control
More informationRepair Parts List REFRIGERATOR MODEL NUMBER JS48SEDBDA. When requesting service or ordering parts, always provide the following information:
Repair Parts List REFRIGERATOR MODEL NUMBER JS48SEDBDA When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model Number - Part Description
More informationIntelligent Compact Controller
TCY-T0121 Intelligent Compact Controller Features Temperature control for 2-pipe, 4-pipe HVAC systems. Temperature range from 40 to 140 C. 1 independent PI and On/Off control loop to control temperature.
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationR PROFLAME Instruction Book Collection
9.956.028 R00 584 PROFLAME Instruction Book Collection 4-17 18-29 584 PROFLAME System 30-39 Appendix: DIP SWITCH NUMBER (0=ON 1=OFF) 40-41 4-17 Fig. 1 The SIT is a device that allows, in conjunction with
More informationUltrasonic level transmitter, non-contact
Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationEFC 3600 Frequency converter for higher energy efficiency and improved process control
EFC 3600 Frequency converter for higher energy eiciency and improved process control 2 Valuable energy used responsibly Rising energy costs and increasing demands on the environmentally sound products
More informationW o r l d C l a s s P o w e r S o l u t i o n s Internal power supply UPS mains operation UPS battery operation Bypass operation Parallel operation Manual bypass Overload Inverter failure Mains failure
More informationWing Gate Instructions. Applicable Models: FB1000 / FB3000 FB1200 / FB3200 Version: 1.0 Date: Jun. 2016
Wing Gate Instructions Applicable Models: FB1000 / FB3000 FB1200 / FB3200 Version: 1.0 Date: Jun. 2016 Contents Chapter 1 Overview... 2 1.1 Product Model and Appearance... 2 1.2 Features... 3 1.3 Technical
More informationFast, precise, powerful
Fast, precise, powerful CNC multi-spindle automatics of the PC series 02 Schütte PC Series Compact design: hydraulic endworking slide feed unit with linear measuring system and control valve Material removal
More informationR&D TECHNICAL SPECIFI
INTRODUCTION Present document defines technical specs of a three phase UPS covering the power range from 20 to 30 kva ON-LINE DOUBLE CONVERSION Uninterruptible Power Supply Systems with forced ventilation
More informationWeeke CNC Machining Center, Model BP-140 ATC Optimat
Weeke CNC Machining Center, Model BP-140 ATC Optimat Weeke's BP-140 is a truly industrial machine designed primarily for pointto-point boring and machining of flat components without special workpiece
More informationProgrammable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual
T3111 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual Instruction manual for use of T3111 transmitters Transmitter
More informationtechnical data air conditioning systems BS box BSVQ-PV1
technical data BS box BSVQ-PV1 air conditioning systems BS box BSVQ100-250PV1 TABLE OF CONTENTS BSVQ100-250PV1 1 Specifications....................................................... 2 Technical Specifications.............................................
More informationEvaporator E2 Series. Innovative Refrigeration Solutions. Medium & Low Temperature Models. Issue: 05/14
Evaporator E2 Series Medium & Low Temperature Models Innovative Refrigeration Solutions Issue: 05/14 APPLICATION BENEFITS / FEATURES HIGH EFFICIENCY HEAT EXCHANGER COIL Capacity steps in the range are
More informationTROUBLESHOOTING. KSIO MINI Split DC Inverter Air Conditioner. Model Numbers:
KSIO MINI Split DC Inverter Air Conditioner TROUBLESHOOTING Model Numbers: KSIO009-H24-I KSIO02-H23-I KSIO08-H22-I KSIO024-H29-I KWIO09-H2 KWIO2-H2 WARNING Installation MUST conform with local building
More informationP2P 2 YEAR PL-VDIO-05. Smartphone Connect IP VIDEO DOOR PHONE QUICK START GUIDE 7 VIDEO DOOR PHONE SYSTEM WITH SMARTPHONE CONNECT
PL-VDIO-05 IP VIDEO DOOR PHONE QUICK START GUIDE Smartphone Connect 2 YEAR RR T SERVICES WA P2P Y Receive calls, remote monitor and remote unlock with your smart phone AN 7 VIDEO DOOR PHONE SYSTEM WITH
More informationTECHNICAL SPECIFICATIONS. FOR AN MRBR 7.0 TESLA / 160mm ACTIVELY SHIELDED ROOM TEMPERATURE BORE MAGNET SYSTEM
TECHNICAL SPECIFICATIONS FOR AN MRBR 7.0 TESLA / 160mm ACTIVELY SHIELDED ROOM TEMPERATURE BORE MAGNET SYSTEM Prepared by:- Magnex Scientific Limited The Magnet Technology Centre 6 Mead Road Oxford Industrial
More information1.0 INTRODUCTION DEFINITIONS DRAWING CONTROL PREPARATION OF SPECIFICATIONS AND DATASHEETS... 5
TABLE OF CONTENTS 1.0 INTRODUCTION... 3 2.0 DEFINITIONS... 4 3.0 DRAWING CONTROL... 4 4.0 PREPARATION OF SPECIFICATIONS AND DATASHEETS... 5 5.0 GUIDELINES FOR PREPARATION OF DRAWINGS... 5 6.0 CONTENTS
More informationRS /E-EV BLU SERIES
The RS/E and RS/EV series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above
More informationMicro-ISO Automotive Relay. (Unit: mm inch)
Micro-ISO Automotive Relay CM RELAYS Flux tight/sealed.. FEATURES Micro-ISO type terminals and small size Wide line-up Compact and high-capacity switching... TYPICAL APPLICATIONS
More informationCONTROLS CS-I. MFDC/AC Inverter Weld Control
CONTROLS MFDC/AC Inverter Weld Control Main Features Power inverter using IGBT technology for medium frequency output, programmable via TFT terminal, LCD terminal and via PC or via field bus. The output
More informationOperation Instruction Manual KAM-TC1000. Precision Temperature Controller
Kamweld Industries Inc. Operation Instruction Manual KAM-TC1000 Precision Temperature Controller Introduction Thank you for purchasing Kamweld's Percision temperature controller, KAM-TC1000. We sincerely
More informationMC16 Mini Vacuum Pressure Casting Machine
MC16 Mini Vacuum Pressure Casting Machine Advanced induction heated casting machine for all standard alloys like gold, silver steel, palladium and platinum alloys are possible to cast. MC 16 offers excellent
More information