AWUF Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features
|
|
- Bonnie Cooper
- 6 years ago
- Views:
Transcription
1 Series Wall-Mount Air Handler 1½ to 3 Tons Contents Nomenclature...2 Accessories...2 Product Specifications...3 Dimensions...6 Airflow Data...8 Wiring Diagram...9 Product Features Equipped with a Check Flowrater for cooling-only and heat pump operation Direct-drive, multi-speed motors allows air volume variation for heating/cooling Multi-speed ECM: 19, 25, 31, 32, 37 Multi-speed PSC motor: 18, 24, 30, 36 Sequence-controlled, rust-resistant nickel chromium heating elements of 3, 5, 8, and 10 kw Aluminum tubing coils on all models AHRI Certified; ETL Listed Factory-installed pull-type disconnect Thermoplastic drain pan with bottom primary and secondary drain connections Built-in filter rack (filter included) Large chassis (2½- and 3-ton units) front return only Small chassis (1½- and 2-ton units) front or bottom return Wall-hanging bracket provided * Complete warranty details available from your local dealer or at To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-G 4/15 Supersedes 3/15
2 Nomenclature A W U F AA ,6 7, ,12 Brand Engineering * A - Single- Piece Air Handler Major/ Minor Revisions Unit Application W - Wall Mount PSC Motor Cabinet Finish U - Unpainted Expansion Device F - Flowrater *Not used for inventory management Refrigerant 6 = R- 410A or R- 22 Electrical 1-208/240 V, 1 Phase, 60 Hz Heater Kit 00 = No Heat 06 = 6 kw Nominal Capacity Range 03 = 3 kw 08 = 8 kw 18, 19 = 1½ Tons 30, 31, 32 = 2½ Tons 05 = 5 kw 10 = 10 kw 24, 25 = 2 Tons 36, 37 = 3 Tons Accessories Model Description Wall access doors Wad-1 fits Wall access doors Wad-1 fits Wall access doors Wad-1 fits 2 SS-G
3 Product Specifications B B B A A A B B B B Nominal Ratings Cooling (BTU/h) 18,000 18,000 18,000 18,000 18,000 18,000 24,000 24,000 24,000 24,000 Electric Heat (kw) Blower Diameter Width Coil Connections Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ⅝" ⅝" ⅝" ⅝" ⅝" ⅝" ⅝" ⅝" ⅝" ⅝" Coil Drain Connection (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Electrical Data Voltage 230/ / / / / / / / / /208 Minimum Circuit Ampacity (230V) Minimum Circuit Ampacity (208V) Max. Overcurrent Device (240V) Max. Overcurrent Device (208V) Minimum VAC Maximum VAC Blower Motor Full Load Amps (FLA) Horsepower (HP) 1/5 1/5 1/5 1/3 1/3 1/3 1/5 1/5 1/5 1/5 Ship Weight (lbs) SS-G 3
4 Product Specifications B B B B B B B B A* A* Nominal Ratings Cooling (BTU/h) 24,000 24,000 24,000 24,000 30,000 30,000 30,000 30,000 30,000 30,000 Electric Heat (kw) Blower Diameter Width Coil Connections Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ⅝" ⅝" ⅝" ⅝" ¾" ¾" ¾" ¾" ¾" ¾" Coil Drain Connection (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Electrical Data Voltage 230/ / / / / / / / / /208 Minimum Circuit Ampacity (230V) Minimum Circuit Ampacity (208V) Max. Overcurrent Device (240V) Max. Overcurrent Device (208V) Minimum VAC Maximum VAC Blower Motor Full Load Amps (FLA) Horsepower (HP) 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/3 1/2 1/2 Ship Weight (lbs) SS-G
5 Product Specifications A* B B B B B B Nominal Ratings Cooling (BTU/h) 30,000 36,000 36,000 36,000 36,000 36,000 36,000 Electric Heat (kw) Blower Diameter Width Coil Connections Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ¾" ¾" ¾" ¾" Coil Drain Connection (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾" Electrical Data Voltage 230/ / / / / / /208 Minimum Circuit Ampacity (230V) Minimum Circuit Ampacity (208V) Max. Overcurrent Device (240V) Max. Overcurrent Device (208V) Minimum VAC Maximum VAC Blower Motor Full Load Amps (FLA) Horsepower (HP) 1/2 1/3 1/3 1/3 1/2 1/2 1/2 Ship Weight (lbs) SS-G 5
6 Dimensions Note - Once installed, top of unit must be level or slightly tilted back to ensure proper condensate drainage. L O W V O L T P O W E R S U P P L Y ( L A R G E C H AS S I S O N L Y ) O F F S E T H AN G I N G B R AC K E T S U C T I O N L I N E L I Q U I D L I N E P U L L O U T DI S C O N N E C T R E M O V AB L E S E R V I C E DO O R L O W V O L T P O W E R S U P P L Y E L E C T R I C AL P O W E R S U P P L Y F R O N T AC C E S S P AN E L S M AL L C H AS S I S S T U D AT T AC H M E N T H O L E S B O T T O M P R I M AR Y AN D S E C O N DAR Y DR AI N S C AN B E AC C E S S E D T H R O U G H T H E B O T T O M O F T H E U N I T. (3 /4 " N P T F E M AL E C O N N E C T I O N ) N O T E : H AN D T I G H T E N O N L Y F R O N T R E T U R N F I L T E R L AR G E C H AS S I S Small Chassis (18-25) Large Chassis (30-37) A 36" A 36" B 20 3 /16" B 24" C 16⅛" C 21" D 16" D 19⅞" E 11" E 15⅞" Filter 14" x 18" x 1" Filter (30, 36,31,32,37) 18" x 20" x 1" 6 SS-G
7 Dimensions D B E C K J TOP VIEW G F I H A Fresh Air Openings Front 4.0" 3.0" 3.0" Bottom L M N BOTTOM VIEW A B C D E F G H I J K L M N " 20¼" 16⅛" 16" 11" 1¾" 1½" 2¼" ⅞" 1⅛" 1¾" 4" 6" 10" " 24" 21" 19⅞" 16" 4⅛" 1½" 1¾" 2" 1¼" 2⅜" 4" 8" 12" SS-G 7
8 Airlfow Data Model 18XX16B* 19XX16A* 24XX16B* 25XX16A* 30XX16B* XX XX XX 36XX16B* 37XX16B* Motor Speed CFM Delivered Against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" High Low T T T T T High Low T T T T T High Low T T T T T T T T T T High Low T T T T T SS-G
9 18/24/30/36 Wiring Diagram 208/230 VOLTS L2 L1 EQUIPMENT OUND G R XFMR-R XFMR-C C EBTDR M1 EBTDR K1 K1 COM M2 NO NC SEE NOTE 5 * TL1 * TL1 HTR1 HTR2* TL2 TL2* * L1 FC HC T1 EM * TL1 TL1 HI SEE NOTE * * HTR 2 TL2 HTR 1 LO TL2 M2 T2 NC HC L2 COM EBTDR SEE NOTE 3 L1 L2 T1 T TR 2 4 EBTDR R TR 4 24 VOLT 5 EBTDR COLOR CODE N.E.C. CLASS 2 WIRE WIRING CODE C COPPER POWER SUPPLY (SEE RATING PLATE) USE MIN. 75 C FIELD WIRE N.E.C. CLASS 2 WIRE HC EVAPORATOR MOTOR LEADS PU COMMON HIGH LOW PU EM RED YL YELLOW UE EM ITE ACK EEN PURPLE OWN COMPONENT CODE ONNECT SWITCH EVAPORATOR MOTOR ELECTRONIC OWER EBTDR TIME DELAY RELAY HC HEATER CONTACTOR NOTES: 1) RED WIRE TO BE ON TRANSFORMER TERMINAL 3 FOR 230 VOLTS AND ON TERMINAL 2 FOR 208 VOLTS. 2) TO PLACE AIRHANDLER IN HIGH SPEED, REMOVE RED MOTOR LEAD FROM ELECTRONIC OWER TIME DELAY RELAY (EBTDR) COM TERMINAL AND REPLACE WITH ACK MOTOR LEAD. ALL UNITS WILL BE FACTORY CONNECTED AT LOW SPEED. 3) SEE COMPOSITE WIRING DIAAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 4) ASTERISK (*) INDICATES THAT HEATING ELEMENT, THERMAL LIMIT, PU AND INTERCONNECTING WIRES AND JUMPERS OF HEATER #2 ARE DELETED WITH SINGLE ELEMENT UNITS. R FC TL TR HTR FACTORY WIRING LOW VOLTAGE FIELD WIRING LOW VOLTAGE RELAY FAN CAPACITOR THERMAL LIMIT TRANSFORMER HEATER ELEMENT CONTROLS SHOWN WITH UTILITIES IN "ON" POSITION AND THERMOSTAT IN "OFF" POSITION. IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMY IS NECESSARY, USE 105 C. WIRE SIZE TO CONFORM TO THE NATIONAL ELECTRIC CODE. FC 5) EBTDR HAS A 7 SECOND ON DELAY EN "G" IS ENERGIZED AND A 65 SECOND OFF DELAY EN "G" IS DE-ENERGIZED. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. NO G R1 NOTE A00282-B SS-G 9
10 19/25 Wiring Diagram NOTES: 1. RED WIRE TO BE ON TRANSFORMER TERMINAL "3" FOR 230 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAPS NEEDS TO BE CHANGED, CONNECT APPROPRIATE WIRE FROM MOTOR TO "Y" FROM THERMOSTAT/CONDENSER (SEE TAE-1). 3. ASTERISK (*) INDICATES THAT HEATING ELEMENT, THERMAL LIMIT, RELAY AND INTERCONNECTING WIRES AND JUMPERS OF HEATER #2 ARE DELETED WITH SINGLE ELEMENT UNITS. 4. COLOR CODES: - ACK - UE - OWN - EEN PU - PURPLE - RED - ITE YL - YELLOW PK - PINK 5. WIRING CODE: FACTORY WIRING: LOW VOLTAGE FIELD WIRING: 6. COMPONENT CODE: C - CONTACTOR - ONNECT SWITCH EM - EVAPORATER MOTOR F - FUSE HTR - HEATER ELEMENT R - RELAY SEQ - SEQUENCER TL - THERMAL LIMIT TR - TRANSFORMER 7. FOR UNITS USING 3KW AND 5KW HEATERS, ITE WIRE WILL BE CONNECTED TO TERMINAL 4. WIRE COLOR BTUh PURPLE PINK TAE-1 FIELD CONNECTIONS SEE NOTE 2 USE N.E.C CLASS 2 WIRE C L2 L1 T2 T1 OPTIONAL CONNECTION UNUSED WIRES MUST HAVE THEIR ENDS TAPED OR CAPPED PU PK MOTOR CONNECTIONS ONLY ONE WILL BE CONNECTED (SEE NOTE 2) PU PK EM CL GN /YL SEE NOTE V 4 240V TR SEE NOTE # 3 HTR 1 HTR 2* SEE NOTE 1 TL1 TL2* F Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 0140A00314-A 10 SS-G
11 31/32 Wiring Diagram NOTES: 1. RED WIRE TO BE ON TRANSFORMER TERMINAL "3" FOR 230 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAPS NEEDS TO BE CHANGED, CONNECT APPROPRIATE WIRE FROM MOTOR TO "Y" FROM THERMOSTAT/CONDENSER (SEE TAE-1). 3. ASTERISK (*) INDICATES THAT HEATING ELEMENT, THERMAL LIMIT, RELAY AND INTERCONNECTING WIRES AND JUMPERS OF HEATER #2 ARE DELETED WITH SINGLE ELEMENT UNITS. 4. COLOR CODES: - ACK - UE - OWN - EEN PU - PURPLE - RED - ITE YL - YELLOW FIELD CONNECTIONS SEE NOTE 2 USE N.E.C CLASS 2 WIRE UNUSED WIRES MUST HAVE THEIR ENDS TAPED OR CAPPED OPTIONAL CONNECTION PU PK YL MOTOR CONNECTIONS ONLY ONE WILL BE CONNECTED (SEE NOTE 2) HTR 1 HTR 2* SEE NOTE # 3 5. WIRING CODE: FACTORY WIRING: LOW VOLTAGE FIELD WIRING: 6. COMPONENT CODE: C - CONTACTOR - ONNECT SWITCH EM - EVAPORATER MOTOR F - FUSE HTR - HEATER ELEMENT R - RELAY SEQ - SEQUENCER TL - THERMAL LIMIT TR - TRANSFORMER WIRE COLOR BTUh NOMINAL CFM PURPLE PINK YELLOW C L2 L1 T2 T1 PU YL PK EM CL GN /YL V 4 240V TR SEE NOTE 1 TAE-1 Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. TL1 TL2* F 0140A00276-A SS-G 11
12 37 Wiring Diagram NOTES: 1. RED WIRE TO BE ON TRANSFORMER TERMINAL "3" FOR 230 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAPS NEEDS TO BE CHANGED, CONNECT APPROPRIATE WIRE FROM MOTOR TO TERMINAL "4" ON RELAY. FIELD CONNECTIONS SEE NOTE 3 USE N.E.C CLASS 2 WIRE 3. SEE COMPOSITE WIRING DIAAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 4. ASTERISK (*) INDICATES THAT HEATING ELEMENT, THERMAL LIMIT, RELAY AND INTERCONNECTING WIRES AND JUMPERS OF HEATER #2 ARE DELETED WITH SINGLE ELEMENT UNITS. 5. COLOR CODES: - ACK - UE - OWN - EEN PU - PURPLE - RED - ITE YL - YELLOW 6. WIRING CODE: FACTORY WIRING LOW VOLTAGE FIELD WIRING LOW VOLTAGE SEE NOTE 3 C 7. COMPONENT CODE: C - CONTACTOR - ONNECT SWITCH EM - EVAPORATER MOTOR F - FUSE HTR - HEATER ELEMENT R - RELAY SEQ - SEQUENCER TL - THERMAL LIMIT TR - TRANSFORMER Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. L2 L1 SPEED TAPS FROM MOTOR SEE NOTE 2 YL OR HTR 1 HTR 2* SEE NOTE 4 T2 T1 B A YL PU PU SEE NOTE 1 OR YL EM CL GN 5 24V 4 /YL 240V TR High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. TL1 TL2* F 0140A00321-A Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA SS-G
TECHNICAL SUPPORT MANUAL Fan Coils FXM4X
Fan Coils FXM4X DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product
More informationTECHNICAL SUPPORT MANUAL Fan Coils
Fan Coils FEM*X, WAHM, WAHT DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used
More informationTECHNICAL SUPPORT MANUAL Builder Series TXV Cased Coils EBU2X
Builder Series TXV Cased Coils EBU2X DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is
More information13acd MERIT SERIES R 22 A I R C O N D I T I O N E R S. SEER up to to 5 Tons Cooling Capacity 17,500 to 60,000 Btuh
E N G I N E E R I N G D A T A A I R C O N D I T I O N E R S 13acd MERIT SERIES R 22 Bulletin No. 210423 April 2008 Supersedes January 2008 SEER up to 14.0 1.5 to 5 Tons Cooling Capacity 17,500 to 60,000
More informationADDENDUM NO. 4 November 15, Page 1
ADDENDUM NO. 4 November 15, 201 8 Page 1 PROJECT MANUAL FOR CONSTRUCTION OF HVAC REPLACEMENT FOR NORTH OCONEE HIGH SCHOOL FOR OCONEE COUNTY SCHOOLS WATKINSVILLE, GEORGIA DATED: SEPTEMBER 14, 2018 CUNNINGHAM,
More information2017 Price List. Krack Corporation Hussmann Corporation St. Charles Rock Rd. Bridgeton, MO Phone: Fax:
Expires: 1/1/2018 2017 Price List Changes since the last Price List: 3.5% Price Increase Effective August 15th Correct SV evaporators pricing. Changes on previous revision: Correct rupture disc assembly
More informationCommercial Refrigeration Price List
Commercial Refrigeration Price List KPL3_004_073118 Effective Date: August 1, 2018 Krack Commercial Refrigeration Price Lists are updated quarterly; January, April, July and October; and posted on our
More informationC0330, C0530, C0630, C0830, C1030 Service Parts
This part list contains the service parts for the air cooled, water cooled and remote air cooled C00, C00, C00, C00, C00 ice machines. There was a change to panels and the C00 air cooled condenser in late
More information(267 kw THROUGH 735 kw)
YCWS (HFC-407C) 50 HZ WATER COOLED LIQUID CHILLERS INSTALLATION, OPERATION AND MAINTENANCE New Release Form 201.24-NM2.1 (202) YCWS WATER COOLED LIQUID CHILLERS YCWS0313SB 0663SB (ADDENDUM FOR HFC-407C
More informationTechnical Information
Date of last update: Aug-14 Ref: REFRIGERATION - CONTROLLING DIGITAL SCROLL Application Engineering Europe 1 Introduction Refrigeration applications such as retail and convenience stores are requesting
More informationThe Ins and Outs of Basic. A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate.
Part 3 The Ins and Outs of Basic Sch ematic Symbols A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate. B y H o w a r d L. P e m p e r, C
More informationMODEL 421 Over/Under Motor Load Monitor
MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart
More informationElectronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards
Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards The Solo, Select and Sync PWM boards provide a pulse-width modulated (PWM) signal to the EC motor to control fan speed.
More informationC0330, C0530, C0630, C0830, C1030 Service Parts
This part list contains the service parts for the air cooled, water cooled and remote air cooled C00, C00, C00, C080, C00 ice machines. To avoid costly and time consuming errors, double check the model
More informationZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP
Product information presented here re fl ects con di tions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO:
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Restrictor Orifice Coils These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly
More informationYD (MOD A-C) WITH OPTIVIEW CONTROL CENTER FIELD CONTROL MODIFICATIONS
Supersedes: 160.69-PW2 (815) Form 160.69-PW2 (116) WIRING DIAGRAM CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. YD (MOD A-C) WITH OPTIVIEW CONTROL CENTER FIELD CONTROL MODIFICATIONS PURCHASER JOB
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationMARK V XCEL SERIES ELECTRIC CONVECTION OVEN REPLACEMENT PARTS LIST
MARK V XCEL SERIES ELECTRIC CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE JANUARY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items
More informationCommercial Microwave Technical Information. CAUTION All safety information must be followed as provided in Service Manual
Commercial Microwave Technical Information 0 V, 0 Hz Models RCS0MPA P00M RCS0A P00M RCS0PBDA P00M RCS0MPSA P00M RFSMPSA P00M RFSSWA P00M RCS0SWA P0M RCS0MPA P0M Due to possibility of personal injury or
More informationEffective october 14, 2014
MARK V XCEL & Mark V-00 XCEL ELECTRIC convection oven REPLACEMENT PARTS LIST Effective october, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event
More informationSenior Swing. Caution
*740132* 740132 2800 Overhead Concealed Series 9500 Surface Applied Series Senior Swing Installation Instructions Caution LCN Senior Swing The Senior Swing Power Operator System is a low energy product
More informationTAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz
TAC ATV8, IP55 Variable Speed Drives for Asynchronous Motors. -phase. 80/460 V, 50-60 Hz E-60-24 24 May 2004 ATV 8 IP55 drives are specifically designed for pump and fan applications powered by a three-phase
More informationWIRING DIAGRAM MANUAL Split System Heat Pump
Split System Heat Pump NXH6 Safety Labeling and Signal Words DANGER, WARNING, AUTION, and NOTE The signal words DANGER, WARNING, AUTION, and NOTE are used to identify levels of hazard seriousness. The
More informationC O P E L A N D C R S E R I E S C O M P R E S S O R S Q U I E T E S T & E F F I C I E N T C O M P R E S S O R S I N T H E I R C L A S S
C O P E L A N D C R S E R I E S C O M P R E S S O R S Q U I E T E S T & E F F I C I E N T C O M P R E S S O R S I N T H E I R C L A S S CONTENTS Page Product Description 1 Features & Performance Story
More informationSPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK
SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK PART 1.0 GENERAL 1.1 SCOPE A. This specification contains the minimum requirements for the design, manufacture and testing of a UL listed,
More informationAHSC OWCB ARCHITECT ENGINEER. (Project) Submittal No. Description: Division: Section: Subcontract/Supplier:
O Neill Walsh Community Builders OWCB Submittal Form ARCHITECT ENGINEER Submittal No. Description: Date: Division: Section: AHSC (Project) Return By: Subcontract/Supplier: The review by O Neill Walsh Community
More informationLow Pass Harmonic Filters
Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power
More informationP/N B ProBlue and DuraBlue Thermostat Service Kit - P/N
P/N 1029717B ProBlue and DuraBlue Thermostat Service Kit - P/N 1028321 This instruction sheet provides separate instructions for replacing a thermostat on ProBlue and a DuraBlue adhesive melters. Tools:
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationHigh Frequency Sinewave Guardian TM Filter
High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationA cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications
A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications The Micro 100 Drives have been designed with a Pulse Width Modulated (PWM) regulator to produce clean DC current to
More informationEVERGREEN EM INSTALLATION GUIDE
EVERGREEN INSTALLATION GUIDE A Regal Brand Genteq s Evergreen is designed to replace O X13 ECM motors quickly and easily with no programming required. Evergreen provides the same comfort, lower utility
More informationSPLIT DUCTED UNIT TECHNICAL SELECTION DATA SRA141C / SRA140E SPECIFICATION SUMMARY UNIT FEATURES CONTROL FEATURES CONTROL OPTIONS. PLENUMS (Optional)
TECHNICAL SELECTION DATA SPLIT DUCTED UNIT 1 SINGLE PHASE SCROLL SINGLE STAGE SS M SOFT START CENTRIFUGAL LOUVRE AXIAL UNIT FEATURES Scroll Compressor Multiple Speed Outdoor Fans Single Phase Soft Starter
More informationInstallation Instructions
001A00 VFD Remote Keypad Kit Installation Instructions SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock or other
More informationZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649
More informationInstallation Instructions
SYSTXBBSAM01 EVOLUTION SYSTEM ACCESS MODULE Installation Instructions NOTE: Read the entire instruction manual before starting the installation. pointsett U.S. Pat No. 7,415,102 Fig. 1 - Evolution System
More informationINSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699)
MILLENNIUM HEAD PRESSURE CONTROL KIT FOR LOW AMBIENT APPLICATIONS INSTALLATION INSTRUCTION Supersedes: 530.70-N.8Y (399) 530.70-N.8Y (99) HEAD PRESSURE CONTROL FOR 208/230 & 0V 25, 30 & 0 TON MILLENNIUM
More informationSmartZone-2 & SmartZone-4
SmartZone-2 & SmartZone-4 Quick-Start Guide UPDATED 2011-7-26 This guide is intended to give the installer a brief set of instructions about how to set up the XCI Zoning SmartZone System. For more detailed
More informationINSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz
POWER QUALITY INSTRUCTION MANUAL Type SWF Sine Wave Filters 690 Volts, 50Hz Page 2 of 24 Contents 1. Introduction & SAFETY 2. Theory of operation 3. Typical results of the Sine Wave Filters 4. Transportation,
More informationHardware Installation Manual
Hardware Installation Manual Modular Silicon Expansion Valve (MSEV) High Capacity Modular Silicon Expansion Valve (HC-MSEV) Universal SuperHeat Controller/Sensor (USHX) Revision 1.5 DunAn Microstaq, Inc.
More informationIRRIGATION 810-3R RECEIVER GUIDE
IRRIGATION 810-3R RECEIVER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 RECEIVER FUNCTION SWITCH SETTINGS 4 RECEIVER INDICATOR LIGHTS 4 SUPERVISION FEATURE 5 RECEIVER HOOKUP TO ENGINE DRIVEN WELL 6 RECEIVER HOOKUP
More informationLow Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned
Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design
More informationInstallation and Operation Manual
SUPER-Selector PT Control Part No. 0 and 0C Installation and Operation Manual CHORE-TIME EQUIPMENT P.O. BOX 000 - MILFORD, DIANA -000 H H SET 0 POT TEMP HIGH TEMP LOW TEMP DANGER TIME ST AGE # TIMER TIME
More informationASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE
ASX SERIES AC POWER SOURCE OPERATION MANUAL PACIFIC POWER SOURCE ASX-SERIES OPERATION MANUAL FOR THE MODELS 115-ASX, 120-ASX 140-ASX, 160-ASX 315-ASX, 320-ASX 345-ASX, 360-ASX 390-ASX, 3120-ASX PPS PART
More informationP o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.
P o w e r C O N T R O L S A N D a t h e n a c o n t r o l s. c o m ATHENA CONTROLS, INC. 5145 Campus Drive Plymouth Meeting, PA 19462-1129 U.S.A. TABLE OF CONTENTS Model Page Series 19/39 1 and Zero-Switched
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS PRODUCTS CCM SERIES NOTE: This document provides the necessary information for the use and operation of Greystone current valves. Greystone Energy Systems Inc. reserves
More informationTFS Application Guide
AG-TFS-00 TFS Application Guide Titus Air Distribution Technologies 605 Shiloh Road Plano, Texas 75074 972.212.4800 www.titus-hvac.com Titus, the Titus Spiral, The Leader in Air Management, Fantom, Fantom
More informationCross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92
Cross Flow Fans Additional Information Technical Reference F-1 General Information G-1 Introduction E-85 MF Series E-88 MFD Series E-92 E-84 ORIENTAL MOTOR GENERAL CATALOG 23/24 Cross Flow Fans Cross flow
More informationProduct Catalog. Split System ACDS-PRC003E-EN. Air-Cooled Condensers 20 to 120 Tons. April 2016
Product Catalog Split System Air-Cooled Condensers 20 to 120 Tons April 2016 ACDS-PRC003E-EN Introduction Trane has the right condenser... If you are designing a new system or replacing an existing aircooled
More informationWarehouse Stock Transformers
Warehouse Stock s Warehouse Stock Buck-Boost Application Description and The Buck-Boost has four separate windings, two-windings in the primary and two-windings in the secondary. The unit is designed for
More informationExtended Wires Extended length wire leads give contractors total flexibility on the installation Insulated flag connectors Hookup is quick and easy
20 1 6 TRIPLE PL AY PROGR AM NOW AVAILABLE! GET IN THE GAME! Includes merchandising and contractor promotion Wagner Motors Aftermarket Tough! Specially engineered for the aftermarket Dependable time tested
More informationMicro and Mini Inverters
Micro and Mini Inverters Why Baldor? For over 85 years, Baldor has strived to provide customers with the best value and reliability in industrial electric motors. That dedication shows in customer preference
More informationDistribution/Substation Transformer
Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation
More informationILLUSTRATED PARTS LIST COUNTERTOP ICEMAKER IMD SERIES
Distributed By: Commercial Refrigeration Service, Inc. http://www.corneliusparts.com http://www.icecubes.net toll free (8) Ice Maker () 89-888 ILLUSTRATED PARTS LIST COUNTERTOP ICEMAKER IMD SERIES IMD
More informationSUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand
More information1 INTRODUCTION ORDER CODE / INFORMATION
INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O
More informationTable of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17
Proximity Section 17 Table of Contents............ 21 2 Application Guide........................ 21 3 ACT Series Transducers......... 21 4 ACTR Series Transducers........ 21 6 ACS150 Series Switches..................
More informationIPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection
IPS INTELLIGENT PUMP STARTER With TM Smartstart Ø & Ø, 0/60 Hz, 20~600 VAC, /~00HP Integrated electronic pump protection overload Power metering and data logging options Motor Protection Key dealer yr.
More informationSealed Interface Control: EC20300
ISO 9001:2000 WITH DESIGN Certificate #02.002.1 Sealed Interface Control: EC20300 FEATURES: Weather tight control package Pulse Width Modulated output Waterproof altitude pressure and vapor release vent
More informationINSTALLATION INSTRUCTIONS At Air-Handler Location
Required Tools: INSTALLATION INSTRUCTIONS At Air-Handler Location Regular Flathead Screw Driver = for thermostat wall plate Mini Flathead Screw Driver = for wire screws Get Started! Small pliers = to better
More informationPower Proportional Distribution (PPD)
AN-PPD-11-18 Power Proportional Distribution (PPD) Application Note Table of Contents 1. Description... 3 2. Application and Design... 3 2.1 PPD Application with an intelligent Touch Controller (itc)...
More informationInstallation, Operation, and Maintenance
Installation, Operation, and Maintenance Source Heat Pump Axiom Horizontal/Vertical GEH/V*, EXH/V* 0.5 to 25 Tons, 50/60 Hz Model Numbers GEHE 006-060 - 50/60 Hz GEVE 006-060 - 50/60 Hz GEHE 072-180 -
More informationDry Type Transformers Full Line Catalog. jeffersonelectric.com
Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production
More informationInstallation instructions for oil unit CADDY FURNACE PA03050 and PA03100
Installation instructions for oil unit CADDY FURNACE PA03050 and PA03100 Read these instructions carefully before installing and operating your furnace. Please keep this document! This manual is available
More informationInstallation & Operation Manual RSDA SERIES. ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65
Installation & Operation Manual RSDA SERIES ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65 Washdown and Watertight for Indoor and Outdoor Use MULTI-FUNCTION KEYPAD WITH 4-DIGIT LED DISPLAY
More informationComputer-14d - xx - 144a
POWER FACTOR REGULATOR Computer-14d - xx - 144a INSTRUCTION MANUAL ( M 981 602 / 98B ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14d --------- Page 2 1.- POWER FACTOR REGULATORS COMPUTER-14d-144a
More informationCATALOG OF REPLACEMENT PARTS
CATALOG OF REPLACEMENT PARTS VELT ELECTRIC TRI-LEG FLOOR MOUNTED TILTING 2/3 JACKETED KETTLES MODEL VELT20 VELT30 VELT40 VELT60 VELT80 VELT100 ML-103442 ML-103443 ML-103444 ML-103445 ML-103446 ML-052999
More informationDISPLAY UNITS (HEATED/CHILLED)
METALCARRELLI 4 DISPLAY UNITS (HEATED/CHILLED) presentation Having always been present in the HO.RE.CA. sector, we have over time managed to develop a range of products for displaying both heated and chilled
More informationRepair Parts List REFRIGERATOR MODEL NUMBER MANUFACTURING NUMBER P W
REFRIGERATOR Repair Parts List MODEL NUMBER 85288 MANUFACTURING NUMBER P1109012W When requesting service or ordering parts, always provide the following information: - Product Type - Part Number - Model
More informationOver or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors
Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2
More informationCONTENTS XV300K GB r doc XV300K 2/13
XV300K CONTENTS 1 PRELIMINARY CHECK GUARANTEE RECYCLING... 3 2 XV300K SPECIFICATIONS OF USE... 3 3 CODES - MODELS... 4 4 TECHNICAL SPECIFICATIONS... 4 5 STANDARD REFERENCES... 5 6 MECHANICAL INSTALLATION...
More informationCompressors, Chillers & Condensers
MARINE CONDENSER ACME MHX MARINE CONDENSER ACME Type MHX condensers are manufactured with the latest technology marine condenser tubing to provide compact size and cost effective use. STANDARD DESIGNS
More informationInstallation Guide. A Regal Brand. EvergreenCM ManPROOF _Fnl.indd 1
Installation Guide A Regal Brand EvergreenCM ManPROOF 100713_Fnl.indd 1 In 1987 General Electric introduced ECM technology to the residential HVAC industry. This technology is predominantly used in variable
More informationPower Supplies 3. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs
More informationECM MOTOR SUPPLEMENTAL MANUAL LIGHT COMMERCIAL UNITS
EM MOTOR SUPPLEMENTAL MANUAL LIGHT OMMERIAL UNITS EM MOTORS FOR: EV0 (IN & RT) HEX (IN & RT) HE.X (IN & RT) MODEL SHOWN: HE.XRT MODEL SHOWN: EV0IN MODEL SHOWN: HEXIN RENEWAIRE.OM EM MOTORS ABOUT RENEWAIRE
More informationJosephson Engineering, Inc. 329A Ingalls Street Santa Cruz, California Josephson Engineering Rev B
C725 Users Guide Josephson Engineering, Inc. 329A Ingalls Street Santa Cruz, California +1 831 420 0888 www.josephson.com 2017 Josephson Engineering Rev B C725 Users Guide Josephson C725 microphones are
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY
INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS
More information2-pole design. New: Semi-hermetic compressors with 2-pole drive motor for mains voltages of 60 Hz. Now for 60 Hz mains voltage
2-pole design Semi-hermetic compressors with 2-pole drive motor for mains voltages of Hz New: Now for Hz mains voltage Baureihe HG series HG 2-pole 2-polig - t a glance t a glance Based on our compressors
More informationLC2D09BL REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationMcQuay. Commercial Unitary Rooftop Cooling with Gas Heat. LGA 088, 100 Design 1. Last Manufactured: 2004
Replacement Parts List No. 700021800 New 08/2011 McQuay Commercial Unitary Rooftop Cooling with Gas Heat LGA 088, 100 Design 1 Last Manufactured: 2004 To find your Daikin Applied parts distributor, call
More informationZone Control Unit (ZCU) VAV Turnkey Solution
Description The Zone Control Unit (ZCU) is a VAV turnkey solution. It is an applied equipment-controls package that is pre-engineered and factory-fabricated, to dramatically reduce field installed equipment
More informationBECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG
PRODUCT CATALOG M O T O R & G E N E R A T O R P R O T E C T I O N BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG Why Your Equipment Needs MEG-ALERT Protection 1 2 3 4 5 6 7 How can you be sure
More informationENCOUNTER AMPLIFIER MANUAL EN-1502 EN-3001 EN-3004
ENCOUNTER ENCOUNTER AMPLIFIER MANUAL EN-1502 EN-3001 EN-3004 ENGLISH AMPLIFIER SPECIFICATIONS EN-3004 (4 Channel) Class Class-AB Class-AB EN-1502 (2 Channel) Power 1800 Watts 1000 Watts Frequency Response
More informationLC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition
Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition
More informationEQUIPMENT INFORMATION SHEET abbreviations REFRIGERATION - MEDIUM TEMP. Link to PDF file CONTRACTOR QTY
Back to index ITEM # RM61.1-08CB Notes and EQUIPMENT INFORMATION SHEET abbreviations REFRIGERATION - MEDIUM TEMP. Link to PDF file CONTRACTOR QTY INFORMATION UTILITY INFORMATION EXT NEW MODEL # ITEM DESCRIPTION
More informationP. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX
SSE-N NEGATIVE FIELD FORCING SHUNT STATIC EXCITER/REGULATOR SYSTEM Control Chassis 6 SCR Power Chassis APPLICATION The SSE-N Negative Field Forcing Exciter/Regulator is used for both new and old installations
More informationFIELD CONTROL MODIFICATIONS MODEL YS CHILLERS (STYLE E)
WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. Supersedes: 60.80-PW5 (999) Form: 60.80-PW5 (5) FIELD CONTROL MODIFICATIONS MODEL YS CHILLERS (STYLE E) PURCHASER JOB NAME LOCATION ENGINEER
More informationInstallation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY
CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CLASS MODEL SERIAL HP Installation Manual Use this manual for circuit
More informationBLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany
2354235 11/2008 Soft start - soft stop unit SH31 User manual 09/2010 BLEMO Frequenzumrichter Siemensstraße 4 D-63110 Rodgau Dudenhofen Germany Tel.: ++49 / 6106 / 82 95-0 Fax: ++49 / 6106 / 82 95-20 Internet:
More informationUNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems
UNITY/I TM UT3K, UT4K, UT5K and UT8K Single-Phase Uninterruptible Power Systems Installation Manual MLS-0351C-OL Copyright 1994-1997 Best Power. All rights reserved. å IMPORTANT SAFETY INSTRUCTIONS! SAVE
More informationInstruction Sheet P/N _06 5/2014
Instruction Sheet P/N 1029717_06 5/2014 ProBlue, ProBlue Liberty, DuraBlue, or Mesa Thermostat Service Kit - P/N 1028321 This instruction sheet describes the procedure for replacing a manifold or tank
More informationINDUSTRIAL DIRECT DRIVE 16 Electric Heated Air Curtain Data Sheet
For Door Heights To 16 (environmental separation) INDUSTRIAL DIRECT DRIVE 16 Data Sheet STANDARD CONSTRUCTION Single speed T.E.A.O. motor(s) - direct drive Gray powder coated exterior (Optional: Custom
More informationDISCONNECT SWITCHES. UL Listed CSA Certified
POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole
More informationContinental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter
Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter Includes the 802A solid -state exciter LED status indicators Features SCR Power Control Automatic RF Power Output Control Automatic SWR Circuit
More informationZone Control Unit (ZCU) Solution
Description The Zone Control Unit (ZCU) is a VAV turnkey solution. It is an applied equipment-controls package that is preengineered and factory-fabricated, to dramatically reduce field installed equipment
More informationArchitect s Letter of Certification
Architect s Letter of Certification Store Name: Center: Space Number: This letter is to serve as certification that the enclosed working drawings for the above referenced space comply with Section of the
More informationCONDENSATE DRAIN PANS
CONDENSATE DRAIN PANS TOTALINE CONDENSATE DRAIN PANS Totaline Condensate Drain Pans prevent harmful overflow moisture from reaching ceiling tiles, insulation or living space. Especially used in the attic
More informationPRODUCT: DODGE PROMASTER MAX SYSTEM 530 / 560 RELEASE DATE: 02/24/15 REVISION DATE: 02/24/15 PART NUMBER: B
Parts List 30 01 000 319 Wire,12 Ga Red w/white Stripe 7 02 000 653 Linestake, 2.5" Vinyl Coated 35 01 000 335 Wire,12 Ga Red 2 02 000 656 Bolt,7/16-14 x 4 1/2 Zinc Plate 30 01 000 421 Wire,6 Ga. Red (Max.
More information