SmartZone-2 & SmartZone-4

Size: px
Start display at page:

Download "SmartZone-2 & SmartZone-4"

Transcription

1 SmartZone-2 & SmartZone-4 Quick-Start Guide UPDATED This guide is intended to give the installer a brief set of instructions about how to set up the XCI Zoning SmartZone System. For more detailed information about the SmartZone Controller, refer to >products> zone controller> SmartZone System Manual. In this document, SmartZone-4 and SmartZone-2 will be referred to as SmartZone. Mounting 1. Remove the clear lid from the SmartZone Enclosure. 2. Using pliers, break out the necessary knock-outs for wiring on the side of the gray base of the SmartZone Enclosure. NOTE: If using the holes on the back of the enclosure for surface mount wiring this may not be necessary. 3. Using flat or pan-head screws (at least 2); mount the gray base of the SmartZone Enclosure on a flat surface. 4. After wiring is completed, replace the clear lid. Power The SmartZone System requires a separate 24VAC transformer for powering the SmartZone Controller Board, Zone Thermostats and Dampers. Connect 24VAC and 24VAC(c) to the POWER Connector on the bottom left of the SmartZone Controller Board. SmartZone-4 TRANSFORMER SIZE = 22VA (for Controller and 4 Thermostats) + 10VA (per Damper) OR 3VA (per POC and RPOC damper). [Example 1: A system with 4 SZD Dampers, the transformer needs to be greater than 62VA] [Example 2: A system with 4 POC (or RPOC) Dampers, the transformer needs to be greater than 34VA] SmartZone-4 (with 3 Zones) TRANSFORMER SIZE = 20VA (for Controller & 3 Stats) + 10VA (per SZD Damper) OR 3VA (per POC and RPOC damper). [Example 1: If the system has 3 SZD Dampers, the transformer needs to be greater than 50VA] [Example 2: A system with 3 POC (or RPOC) Dampers, the transformer needs to be greater than 29VA] SmartZone-2 TRANSFORMER SIZE = 18VA (for Controller and 2 Thermostats) + 10VA (per SZD Damper) OR 3VA (per POC and RPOC damper). [Example 1: If the system has 2 SZD Dampers, the transformer needs to be greater than 38VA] [Example 2: A system with 2 POC (or RPOC) Dampers, the transformer needs to be greater than 24VA] XCI Zoning Page 1 of 12 P/N

2 Wiring Thermostats Wiring SmartZone will operate using thermostats that have a common or are battery operated, follow the below steps to connect each of the thermostats to the SmartZone Controller Board. 1. Connect either single stage heat pump thermostats or gas/electric thermostats to each terminal block labeled THERMOSTAT 1 through The THERMOSTAT 1 will operate ZONE 1 damper, THERMOSTAT 2 will operate ZONE 2 damper and so on through THERMOSTAT Hold down the orange button adjacent to the terminal openings and push the thermostat wires into SCREWLESS terminals labeled R,C,Y,G,W and O/B (as applicable). 4. Connect the other end of the thermostat wire to the thermostat for the associated ZONE. XCI Zoning Page 2 of 12 P/N

3 Damper Wiring When using Power Close/Spring Open dampers follow the steps below to connect each of the dampers to the SmartZone Controller Board: 1. Use 18/2 or 18/3 solid core wire 2. Hold down the orange button adjacent to the terminal block openings labeled Z1-PC and COM and push wires for the ZONE damper into the SCREWLESS terminals. 3. Connect the other end of the wire to the SCREWLESS terminals on the ZONE damper. If using a Power Open/Power Close damper follow the steps below to connect each of the dampers to the SmartZone Controller Board: 1. Use 18/3 solid core wire 2. Hold down the orange button adjacent to the terminal block openings labeled Z1-PC, COM and Z1-PO and push wires for the ZONE damper into the SCREWLESS terminals. 3. Connect the other end of the wire to the SCREWLESS terminals on the ZONE damper. Supply Air Temperature Sensor [SA Sensor] Wiring Sensor Placement (Location) Gas/Electric and Dual Fuel Sensor should be located in Supply Air Plenum where it will sense AVERAGE air temperature within the plenum. The most ideal placement for the Sensor will be 2 to 4 feet beyond the evaporator. Make sure the sensor is in the air stream and secured properly. Heat Pump The sensor is placed inside the cabinet of the air handler after the coil but before the blower. Make sure the sensor is in the air stream and secured properly. Sensor Wiring Using the provided GREEN connector (Factory Connected to Sensor Wire) plug the SA Sensor wire into the SmartZone Controller Board. NOTE: WITHOUT THIS SENSOR, THE SmartZone CONTROLLER BOARD WILL NOT OPERATE. XCI Zoning Page 3 of 12 P/N

4 Note: On standard heat pumps with electric air handlers, SAS is located in air handler between indoor coil and blower. Equipment Wiring Connect the Equipment Control Wires from the Unit to the EQUIPMENT Terminal Block on the Top Right of the SmartZone Controller Board. Use the terminal labeled W1 EH for 1st stage heat when using gas/electric equipment or emergency heat on heat pump. Use the terminal labeled W2 O/B on 2 nd stage heat on gas/electric equipment. Use the terminal labeled W2 O/B for reversing valve when using heat pump. NOTE: THE C TERMINAL MUST BE CONNECTED TO THE CONTROLLER AND EQUIPMENT IN ORDER FOR THE EQUIPMENT RELAYS TO ENERGIZE. POWER FROM THE EQUIPMENT TRANSFORMER WILL ILLUMINATE THE RC AND RH TERMINAL LEDs INDICATING THE EQUIPMENT TRANSFORMER IS CONNECTED. *See next page for wiring diagrams. XCI Zoning Page 4 of 12 P/N

5 GAS-ELECTRIC SYSTEM WIRING HEAT PUMP SYSTEM WIRING XCI Zoning Page 5 of 12 P/N

6 Configuration DIP Switches ALL of these DIP Switches MUST BE SET according to the equipment type, thermostats being used as well as the desired functionality of the SmartZone System. If not, unpredictable and undesirable results may occur. See the table below for DIP Switch descriptions. DIP #1 DIP #2 NORMAL DUAL FUEL ALL Z1 PRIORITY Operates electric auxiliary heat with compressor. (Factory Default) Operates gas auxiliary heat with NO compressor HEAT PUMP ONLY. Allows any thermostat to change equipment mode. (Factory Default) Allows ZONE 1 to control equipment mode unless satisfied. DIP #3 DIP #4 15 MIN 15 Minute delay between opposing calls. (Factory Default) 10 OP CALL 10 Minute delay between opposing calls. 2 nd STAGE Normal Operation 2 nd Stage is always active. (Factory Default) LOCK OUT Will not Allow 2 nd Stage if only one ZONE is calling. DIP #5 DIP #6 REV VLV O B SYS G/E HEAT PUMP Reversing valve is energized in COOLING. (Factory Default) Reversing valve is energized in HEATING. Gas/Electric or Electric/Electric Equipment. (Factory Default) Heat Pump Equipment ONLY. XCI Zoning Page 6 of 12 P/N

7 Configuration (Continued) Push Buttons The push buttons are used for several different functions. See descriptions below for information on how to use the buttons to setup and view SmartZone Controller settings. Fresh-Air Damper Time To set the Minutes-Per-Hour that the Fresh-Air Damper is OPEN follow the below steps: 1. While the SmartZone Controller Board is powered, press and quickly release BOTH the UP and DOWN Arrow buttons at the same time. The Green FRESH AIR indication will begin to flash. 2. Within 5 seconds press either the UP or the DOWN Arrow button to change the time. The time is indicated in Number of Minutes-Per-Hour that the Fresh-Air Damper will be OPEN. 3. After the desired time has been selected, wait 5 seconds and ST will flash on the Display, indicating that the time has been set. NOTE: If NO Fresh Air Damper is installed, 0 (Zero) Time must be set or the equipment fan will run unnecessarily. Electronic Limit Control TM (ELC) To set the High and Low Temperature Equipment Cut-Out SetPoints follow the below steps, before completing these steps, ensure that DIP #6 is set correctly choosing the proper equipment type. HIGH Temperature Cut-Out (Factory Default - GAS/ELECTRIC = 135 F; HEAT PUMP = 120 F) 1. While the SmartZone Controller Board is powered, press momentarily and release the UP arrow to set the HIGH Temperature Cut-Out. The Red HI TEMP indication with begin to flash. 2. Within 5 seconds press either the UP or the DOWN Arrow button to change the HIGH Temperature Cut-Out. The temperature indicated here represents the highest temperature allowed at the supply air sensor. 3. After the desired temperature has been selected, wait 5 seconds and ST will flash on the Display, indicating that the HIGH Temperature Cut-Out has been set. LOW Temperature Cut-Out (Factory Default - GAS/ELECTRIC = 48 F; HEAT PUMP = 48 F) 4. While the SmartZone Controller Board is powered, press momentarily and release the DOWN arrow to set the LOW Temperature Cut-Out. The Red LO TEMP indication with begin to flash. 5. Within 5 seconds press either the UP or the DOWN Arrow button to change the LOW Temperature Cut-Out. The temperature indicated here represents the lowest temperature allowed at the supply air sensor. 6. After the desired temperature has been selected, wait 5 seconds and ST will flash on the Display, indicating that the LOW Temperature Cut-Out has been set. XCI Zoning Page 7 of 12 P/N

8 Configuration (Continued) Dual Fuel (Gas Furnace add on to heat pump) Applications Note 1: Note 2: A DUAL FUEL KIT IS NOT REQUIRED and HEAT PUMP THERMOSTATS ARE NOT REQUIRED ON #2, #3, AND #4 ZONES. Use Heat Pump stat in the #1 ZONE ONLY for EMERGENCY HEAT. When using the TSZ-1 thermostat, use the Wireless Outdoor Temperature Transmitter (Part #TOS) with the TSZ-1 thermostat to control emergency heat mode using outdoor temperature through the heat pump thermostat in the #1 position. Always install the heat pump evaporator downstream of the furnace. This prevents condensation in the heat exchanger during the cooling mode. 1. The HIGH Temperature Cut-Out for the gas furnace in a dual fuel application can only be identified and adjusted when the # 6 dipswitch is in the GAS FURNACE position. 2. The HIGH Temperature Cut-Out for the heat pump in a dual fuel application can only be identified and adjusted when the # 6 dipswitch is in the HEAT PUMP position. 3. The LOW Temperature Cut-Out for the HEAT PUMP in a dual fuel application is the same as described earlier on page 6 (LOW Temperature Cut-Out). Thermostat Type NOTE: THIS ONLY APPLIES TO HEAT-PUMP INSTALLATIONS To set type of Thermostat being used on the system follow the below steps: 1. While the SmartZone Controller Board is powered, press AND HOLD both the UP and DOWN Arrow buttons until the Numeral 1 appears [this Numeral is an indication of the ZONE Thermostat number], then either GE or HP will appear on the display. 2. Within 5 seconds press the DOWN Arrow button to toggle between the thermostat types. GE = Gas/Electric Thermostat; HP = Heat Pump Thermostat 3. After the desired thermostat type has been selected for this ZONE, press the UP arrow (within 5 seconds) to select the next zone. The Numeral 2 will appear [this Numeral is an indication of the ZONE Thermostat number], then either GE or HP will appear on the display. 4. Repeat Steps 2 and 3 for each of the ZONEs being used. 5. After all thermostat types have been selected for each ZONE, wait 5 seconds and ST will flash on the Display indicating that the Thermostat Type has been set. NOTE: For Emergency Heat to be utilized, Zone #1 MUST have a Heat Pump thermostat connected. RC/RH Jumper The RC/RH Jumper is Factory Installed on the SmartZone Controller Board. If the system being used requires separate Heat and Cool Transformers, REMOVE this jumper [JP2] at the top right of the board. Note: In the case of a Heat-Pump System, this Jumper ALWAYS needs to be installed. XCI Zoning Page 8 of 12 P/N

9 Operation Equipment LEDs Diagnostic LEDs indicate which equipment circuits are energized with 24VAC. When no R LED is on, check power from the HVAC unit. Thermostat LEDs Each LED indicates what mode is being powered through the thermostat. The Red LED adjacent to R indicates SmartZone has power available for the thermostat. The Yellow LED adjacent to Y indicates a compressor call from the thermostat. The Green LED adjacent to the G indicates Fan call from thermostat. The Red LED adjacent to the W indicates a Heat call from thermostat. The Red LED adjacent to the O/B indicates Reversing Valve call from thermostat. Damper LEDs Red LED indicates damper is powered closed. Green LED indicates damper is open. Emergency Heat Lock This feature has been implemented to ensure that once the system has been set to Emergency Heat (EH), the compressor will not be energized until the system has been taken out of EH mode. ONLY Zone#1 Thermostat can set the equipment into EH mode. Zone#1 Thermostat must be making a call for EH to set the SmartZone-2 or -4 into EH mode. Once the SmatZone-2 or -4 has been set into EH by Zone#1 Thermostat, it is Locked in EH mode and will not make any compressor calls until it has been UN-Locked Any cooling calls from thermostats other than Zone#1 thermostat will be ignored while in EH Lock mode. Any heating calls from thermostats other than Zone#1 will be treated as EH calls while in EH Lock mode. To UN-Lock EH mode, a call must be made from the Zone#1 thermostat for anything other than EH. o NOTE: Zone#1 Thermostat must not only be switched out of EH mode but ALSO must MAKE a call for another mode (either Heat-Pump Heat or Cool). If no call is made from Zone#1 Thermostat then the SmartZone-2 or -4 will remain in EH Lock until Zone#1 does make a call no matter what the other zones are calling for. Time Delay After all calls have been satisfied and the equipment is turned off, all dampers open and a 3-minute Time Delay will start during which the equipment cannot be energized. This is designed to protect the equipment from re-starting for 3-minutes after it has stopped running. During the 3-minute Time Delay, the SmartZone Controller will not energize the fan. However, the fan may continue to run if the equipment being used has a built in off-time-delay. NOTE: There is NO visual indication of the Time Delay on the SmartZone Controller other than the fact that there will be no equipment calls regardless of what the thermostats call for during the 3-minute duration. Purge The Purge Mode is a three-minute time period that allows the blower to continue to operate during Opposing Call Changeover. During the Purge, no heating or cooling equipment will be energized. Purge mode is designed to prevent equipment from operating for three minutes so that HVAC system pressures and temperatures can equalize. During the three-minute Purge Mode, zones with calls for the opposite mode that was last being satisfied will have dampers closed. All other dampers (ones associated with non-calling zone(s) and last zone(s) being satisfied) will remain open during Purge Mode. XCI Zoning Page 9 of 12 P/N

10 Equipment Staging Cooling Air Conditioning and Heat Pump: First stage occurs any time there is a call for cooling or a changeover from heating to cooling. Y1 and G are energized. In heat pump cooling mode OB may also be initiated. After 8 minutes of initial run time in first stage, the ELC (Electronic Limit Control) will initiate Y2 if the supply air temp has not dropped below 10 degrees above the Low Temp Cut-Out temperature. Once second stage is initiated, if the supply air temp goes below 4 degrees above the Low Temp Cut- Out, Y2 is de-energized and only Y1 and G are energized. This scenario is repeated as dictated by the supply air temp. Heating Gas, Electric and Fuel Oil Heating First stage occurs anytime there is a call for heating or a changeover from cooling to heating. W1/EH and G are energized. After 8 minutes of initial run time in first stage, the ELC will initiate W2/OB if the supply air temp has not risen above 25 degrees below the High Temp Cut-Out temperature. Once second stage is initiated, if the supply air temp rises above 10 degrees below the High Temp Cut-Out, W2/OB is de-energized and only W1 and G are energized. This scenario is repeated as dictated by the supply air temp. Heat Pump Heating with Electric Backup First stage occurs anytime there is a call for heating or a changeover from cooling to heating. Y1 and G are energized. In heat pump heating mode OB may also be initiated. After 4 minutes of initial run time in first stage, the ELC will initiate Y2 if supply air temp has not risen above 15 degrees below the High Temp Cut-Out temperature. Once second stage is initiated, if the supply air temp rises above 5 degrees below the High Temp Cut-Out, Y2 is de-energized and only Y1 and G are energized. Auxiliary Heat - After 6 minutes of initial run time, if the supply air temp drops below 90 degrees, W1/EH will be energized. If the supply air temp rises above 100 degrees W1/EH will be de-energized and only Y1, Y2 and G will be energized. This scenario is repeated as dictated by the supply air temp. Emergency Heat - can only be initiated thru a heat pump stat in the # 1 position. If this stat is placed in Emer Heat, the SmartZone board is latched into emergency heat. No compressor will run and only heating calls will be recognized. Remove the Emer Heat call at stat #1 and make a call for something other than Emer Heat from stat #1 in order to unlatch the board and take it out of emergency heat. Heat Pump Heating with Fossil Fuel Backup (Dual Fuel) First stage occurs anytime there is a call for heating or a changeover from cooling to heating. Y1 is energized. In heat pump heating mode OB may also be initiated. After 4 minutes of initial run time in first stage, the ELC will initiate Y2 if supply air temp has not risen above 15 degrees below the High Temp Cut-Out temperature. Once second stage is initiated, if the supply air temp rises above 5 degrees below the High Temp Cut-Out, Y2 is de-energized and only Y1 is operating. This scenario is repeated as dictated by the supply air temp. Auxiliary Heat - After 6 minutes of initial run time, if the supply air temp drops below 90 degrees, W1/EH will be energized. This will remove Y1 and Y2 and energize W1/EH. W1/EH will initiate start up of the fossil fuel furnace. Only the W1/EH and G will remain energized for the remainder of the heating cycle. Emergency Heat - can only be initiated thru a heat pump stat in the # 1 position. If this stat is placed in Emer Heat, the SmartZone board is latched into emergency heat. No compressor will run and only heating calls will be recognized. Only the W1/EH and G will remain energized for the remainder of the heating cycle. Remove the Emer Heat call at stat #1 and make a call for something other than Emer Heat from stat #1 in order to unlatch the board and take it out of emergency heat. XCI Zoning Page 10 of 12 P/N

11 Operation (Continued) Display Display Indicator HI TEMP LO TEMP SUPPLY FRESH AIR PURGE Status Flashing ON OFF Flashing ON OFF Flashing ON OFF Flashing ON OFF ON OFF Description During adjustment of HIGH Temperature Cut-Out (described above) Supply Air Temp has been above HIGH Temp Cut-Out in the last 3 minutes Normal Operation (Supply Air Temp is below HIGH Temp Cut-Out) During adjustment of LOW Temperature Cut-Out (described above) Supply Air Temp has been below LOW Temp Cut-Out in the last 3 minutes Normal Operation (Supply Air Temp is above LOW Temp Cut-Out) Indicates that NO Supply Air Temp Sensor is Connected to SmartZone Normal Operation (Indicates the Temp displayed is the Supply Air Temp) During adjustment of Thermostat Types (described above) During adjustment of Fresh-Air Damper Time (described above) Indicates that the Fresh-Air Damper is OPEN Indicates that the Fresh-Air Damper is CLOSED During System Purge and Opposing Call Changeover Indicates NO Purge condition XCI-HVAC XCI Zoning Page 11 of 12 P/N

12 The thermostat wiring on this diagram is intended as a general guide; refer to the installation guide provided with the thermostat being used for specific wiring information. XCI Zoning Page 12 of 12 P/N

INSTALLATION INSTRUCTIONS At Air-Handler Location

INSTALLATION INSTRUCTIONS At Air-Handler Location Required Tools: INSTALLATION INSTRUCTIONS At Air-Handler Location Regular Flathead Screw Driver = for thermostat wall plate Mini Flathead Screw Driver = for wire screws Get Started! Small pliers = to better

More information

Smartzone LCD TOUCHPAD USER GUIDE.

Smartzone LCD TOUCHPAD USER GUIDE. Smartzone LCD TOUCHPAD USER GUIDE www.ias.net.au TOUCHPAD USER GUIDE Touchpad and Display Layout PAGE 2 TOUCHPAD USER GUIDE Dual Line Back lit LCD Display With scrolling zone summary Change variable values

More information

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards The Solo, Select and Sync PWM boards provide a pulse-width modulated (PWM) signal to the EC motor to control fan speed.

More information

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION GUIDE SPECIFICATIONS 256920-UGS-A-0506 Simplicity Intelli-Comfort Optional Control in 3-25 Ton Packaged Units GENERAL DESCRIPTION CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP Equipment with Simplicity

More information

Model 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR

Model 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR Model 12200A RCN PTAC/PTHP/ COIL CONTROL NODE OPERATION OUTPUTS G1 = 1 G2 = 2 G3 = 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR Operating Modes Summary (Refer to Logic Tables 1 5): 1. PTAC (Standard) Fan

More information

ELECTRONIC THERMOSTAT: T920

ELECTRONIC THERMOSTAT: T920 μnistδt ELECTRONIC THERMOSTAT: T One analog output DESCRIPTION The T series thermostats are microcomputer-based, proportional and integral (PI) devices with one analog 0 to 0 output. They can be used with

More information

IRRIGATION 810-3R RECEIVER GUIDE

IRRIGATION 810-3R RECEIVER GUIDE IRRIGATION 810-3R RECEIVER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 RECEIVER FUNCTION SWITCH SETTINGS 4 RECEIVER INDICATOR LIGHTS 4 SUPERVISION FEATURE 5 RECEIVER HOOKUP TO ENGINE DRIVEN WELL 6 RECEIVER HOOKUP

More information

ELECTRONIC THERMOSTAT: T951

ELECTRONIC THERMOSTAT: T951 μnistδt ELECTRONIC THERMOSTAT: T9 One floating output One contact output DESCRIPTION The T9 series thermostats are microcomputer-based, proportional and integral (PI) devices with one floating (incremental)

More information

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting FANs 216, 121 Technical Bulletin R48 Issue Date 0695 Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting Table of Contents Mounting... 1 Output Control... 2 Wiring...

More information

Wireless Temp/Setpoint & Override Room Transmitter

Wireless Temp/Setpoint & Override Room Transmitter Overview The BAPI Wireless Combination Transmitter measures the room temperature and relative humidity and transmits the data at 418MHz or 433MHz RF to a receiver. Temperature setpoint and override button

More information

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL This manual covers installation, setup, operation and troubleshooting. Read carefully before attempting to install, operate or

More information

Wireless Rain and Wireless Rain/Freeze Sensor

Wireless Rain and Wireless Rain/Freeze Sensor Wireless Rain and Wireless Rain/Freeze Sensor Installation and Operating Instructions for: WRC: Wireless Rain Sensor Combo WRT: Wireless Rain Sensor Transmitter WSR: Wireless Rain Sensor Receiver WRFC:

More information

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions Wireless Temperature and Humidity Overview and Indentification The Wireless Temperature and Humidity measures the room temperature and Relative Humidity and transmits the data at 418MHz or 433MHz RF to

More information

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification General The VT76x7 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop

More information

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions Overview and Identification The BAPI-Stat 4 X-Combo () Room Unit features 4 output channels and optional local indication of temperature and humidity. Additional options include Temperature Setpoint, Humidity

More information

Industrial Pipe Marking

Industrial Pipe Marking Industrial Pipe Marking Pipe and Valve Identification Specialists SPECIFICATIONS ASME (ANSI) Standard A13.1-2007 The ASME (ANSI) Standard for pipe identification is a widely used guideline in determining

More information

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The switch followers are a two way system designed to provide a quick and cost effective

More information

Guidelines to Using a Three Phase Voltage Monitor

Guidelines to Using a Three Phase Voltage Monitor September 2000 Guidelines to Using a Three Phase Voltage Monitor Introduction A phase monitor can be used with any three phase motor. A monitor such as the Copeland 085-0160-00 is recommended for monitoring

More information

TLC3-BCR-U Series Thermostat

TLC3-BCR-U Series Thermostat OVERVIEW TLC3-BCR-U Series Thermostat Features Low power energy consumption: < 1W per unit Relays switching for outputs each up to 300W Temperature control for 2 or 4-pipe heating or cooling systems. Optional

More information

Installation Instructions

Installation Instructions SYSTXBBSAM01 EVOLUTION SYSTEM ACCESS MODULE Installation Instructions NOTE: Read the entire instruction manual before starting the installation. pointsett U.S. Pat No. 7,415,102 Fig. 1 - Evolution System

More information

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS OWNERS MANUAL FOR STERLING SERIES CONTROLLERS 24950 AVENUE KEARNY, VALENCIA, CALIFORNIA 91355-2142 PHONE (661) 257-3533 FAX (661) 257-9472 TABLE OF CONTENTS Selecting the Location for the Controller...3

More information

Setup Guide. support.spruceirrigation.com.

Setup Guide. support.spruceirrigation.com. FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device

More information

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B Instruction Sheet P/N 1047806B Installation of Fillmaster DuraBlue Melters System on WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use

More information

CONTENTS Installation Location

CONTENTS Installation Location PIR Ready VT7600 Series With & Without Local Schedule Terminal Equipment Controllers Installation Guide For Commercial HVAC Applications November 04 th, 2011 / 028-0228-R5 CONTENTS Installation Location

More information

TE-7800 Series One-to-One Wireless Room Temperature Sensing System

TE-7800 Series One-to-One Wireless Room Temperature Sensing System TE-7800 Series One-to-One Wireless Room Temperature Sensing System Technical Bulletin TE-7820-0, TE-7830-0, TE-7820-1, TE-7830-1 Code No. LIT-12011097 Issued October 4, 2010 Supersedes October 6, 2008

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10

More information

BFS / BFSM SERIES Installation & Maintenance Manual

BFS / BFSM SERIES Installation & Maintenance Manual Introduction: The BFS / BFSM series electric actuators have battery backup modules for fail safe operation. The BFS series is for two position control and the BFSM series is for proportional control, both

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 SUBMITTALS A.

More information

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER Honeywell RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER W7620 Zone Controller Water Source Heat Pump - -.> The W7620 Zone Controller provides customized control of HVAC zone equipment.

More information

EUROSTER 2026/2026TX

EUROSTER 2026/2026TX EUROSTER 2026/2026TX - User Manual 1 EUROSTER 2026/2026TX 1. CHARACTERISTICS 4 different programs for each day of the week (28 different ranges and temperatures altogether). Time programming with 10 minutes

More information

MULTISTACK The Modular Water Chiller

MULTISTACK The Modular Water Chiller MULTISTACK The Modular Water Chiller BACnet Portal Technical Manual MULTISTACK WEB PORTAL MS20/30/50 HEAT PUMP Application - BACnet over TCP/IP MULTISTACK 1065 Maple Ave. Sparta, WI 54656 PHONE #: (608)

More information

REFERENCE AIRBASS Wireless Subwoofer Volume Control System

REFERENCE AIRBASS Wireless Subwoofer Volume Control System REFERENCE AIRBASS Wireless Subwoofer Volume Control System This device complies with F.C.C. Rules part 15. Operation is subject to the following two conditions: (1) This device may not cause harmful interference

More information

C0330, C0530, C0630, C0830, C1030 Service Parts

C0330, C0530, C0630, C0830, C1030 Service Parts This part list contains the service parts for the air cooled, water cooled and remote air cooled C00, C00, C00, C080, C00 ice machines. To avoid costly and time consuming errors, double check the model

More information

Digital Room Sensor Technical Guide

Digital Room Sensor Technical Guide www.orioncontrols.com Digital Room Sensor Technical Guide TABLE OF CONTENTS OVERVIEW... 3 BASIC OPERATION... 4 Sensor Operation... 4 LED Operation... 4 MOUNTING AND WIRING... 5 Environmental Requirements...

More information

Universal Controller

Universal Controller Universal Controller Overview and Configuration Manual Overview... 1 About this Manual... 1 Introduction... 5 Hardware Overview... 5 Software Overview... 7 Interpreting Flow Diagrams... 8 Foreign Language

More information

Installation and Operation Manual

Installation and Operation Manual SUPER-Selector PT Control Part No. 0 and 0C Installation and Operation Manual CHORE-TIME EQUIPMENT P.O. BOX 000 - MILFORD, DIANA -000 H H SET 0 POT TEMP HIGH TEMP LOW TEMP DANGER TIME ST AGE # TIMER TIME

More information

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version MR9 WARRANTY Steffes Corporation ( Steffes ) warrants that the Steffes Power Line Carrier Mini Receiver is free from defects in materials and workmanship under normal use and service. Steffes obligation

More information

RWD44U Controller. Installation and Commissioning Guide Document No October 5, Function. Application

RWD44U Controller. Installation and Commissioning Guide Document No October 5, Function. Application RWD44U Controller Installation and Commissioning Guide Document No. 129-408 Function RWD44U controllers are intended for HVAC and Refrigeration systems including Heat Pumps. They are suitable for 1-, 2-,

More information

CONTENTS Installation Location

CONTENTS Installation Location 1 PIR Ready SE7600 Series With & Without Local Schedule Terminal Equipment Controllers Installation Guide For Comme rcial HVAC Applications CONTENTS Installation Location Installation Theory of operation

More information

Multiple Program Process Temperature Controller. Installation Guide Maxitrol Company, All Rights Reserved

Multiple Program Process Temperature Controller. Installation Guide Maxitrol Company, All Rights Reserved + Multiple Program Process Temperature Controller Installation Guide www.maxitrol.com Warnings Inappropriate and/or improper installation, adjustment, alteration, service or maintenance can cause property

More information

SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller Version 10 2 HMI Display The User HMI is configurable and allows display functions such as Date, Time, Outdoor

More information

CONTROL MANUAL. Dry-Pic 09PE - 09VE

CONTROL MANUAL. Dry-Pic 09PE - 09VE CONTROL MANUAL Dry-Pic 09PE - 09VE Translation of the original document 003, 04.01 EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth

More information

C0330, C0530, C0630, C0830, C1030 Service Parts

C0330, C0530, C0630, C0830, C1030 Service Parts This part list contains the service parts for the air cooled, water cooled and remote air cooled C00, C00, C00, C00, C00 ice machines. There was a change to panels and the C00 air cooled condenser in late

More information

Operating Instructions

Operating Instructions LR650 Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product to. Comply with all

More information

Connect + compatible

Connect + compatible Connect + compatible Looking for a quick setup up guide? There is lots of useful information in this book, but if all you are after is quick set up look for the following headings in this book 1) Setting

More information

Installation Guide. Contents. VT7600E Series RTU Terminal Equipment Controller with IAQ Control

Installation Guide. Contents. VT7600E Series RTU Terminal Equipment Controller with IAQ Control VT7600E Series RTU Terminal Equipment Controller with IAQ Control Installation Guide For Commercial HVAC Applications February 25th, 2014 / Contents Installation 2 Location 2 Installation 2 Theory of Operation

More information

Self-learning Room Temperature Controller Receiver

Self-learning Room Temperature Controller Receiver 2 265 REV23RF REV-R.02/1 REV23RF/SE Self-learning Room emperature Controller Receiver Consisting of controller (with integrated radio transmitter) and receiver (switching unit with relay outputs) REV23RF

More information

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology Instruction Bulletin 63249-420-283A4 08/2009 Wall Mount Occupancy Sensor SLSWPS1500, SLSWUS1500, SLSWDS1500 INTRODUCTION Wall Mounted Occupancy Sensors are Class 2 devices ideal for use in business or

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION Buebtel/Perlcins Community Learning Center GPD - 2001271.15 SECTION 15075 MECHANICAL IDENTIFICATION PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General

More information

W7100A-E Discharge Air Controller

W7100A-E Discharge Air Controller W7100A-E W7100A-E Discharge Air Controller The microprocessor based W7100 Discharge Air Controller maintains an average discharge air (DA) temperature in variable air volume (VAV) cooling systems by modulating

More information

Installation Instructions

Installation Instructions nstallation nstructions NOTE: Read the entire instruction manual before starting the installation. pointset " U.S. Pat No. 7,415,102,,,. J Fig. 1 - nfinity System Access Module SYSTXCCSAM01 TABLE OF CONTENTS

More information

Technical Information

Technical Information Date of last update: Aug-14 Ref: REFRIGERATION - CONTROLLING DIGITAL SCROLL Application Engineering Europe 1 Introduction Refrigeration applications such as retail and convenience stores are requesting

More information

RWD68U Controller. Installation and Commissioning Guide Document No October 1, Function. Application

RWD68U Controller. Installation and Commissioning Guide Document No October 1, Function. Application RWD68U Controller Installation and Commissioning Guide Document No. 129-411 Function Application The RWD68U is a three-input, two-output device used to control temperature, humidity, air pressure, fluid

More information

PWM. Design, Installation, and Operation. (Pulse Width Modulation Zone Controller)

PWM. Design, Installation, and Operation. (Pulse Width Modulation Zone Controller) Small Duct Heating, Cooling and Indoor Air Quality Systems www.hi-velocity.com TM PWM (Pulse Width Modulation Zone Controller) Design, Installation, and Operation Includes: PWM Design PWM Installation

More information

AURATON 2020 AURATON 2020 TX RX Plus

AURATON 2020 AURATON 2020 TX RX Plus 0 I 31 EN AURATON 2020, AURATON 2020 TX RX Plus AURATON 2020 AURATON 2020 AURATON 2020 TX RX Plus Preliminary notes The manual includes the information on AURATON 2020 and AURATON 2020 TX RX Plus controllers.

More information

BOILER MANAGEMENT SYSTEM

BOILER MANAGEMENT SYSTEM BOILER MANAGEMENT SYSTEM g y ( ) Table of Contents Page SECTION 1 ABOUT YOUR NEW BOILER MANAGEMENT SYSTEM (BMS) 1-1 SECTION 2 FEATURES OF THE BMS 2-1 SECTION 3 INSTALLING THE BMS 3-1 3.1 MOUNTING THE BMS

More information

ADDENDUM NO. 4 November 15, Page 1

ADDENDUM NO. 4 November 15, Page 1 ADDENDUM NO. 4 November 15, 201 8 Page 1 PROJECT MANUAL FOR CONSTRUCTION OF HVAC REPLACEMENT FOR NORTH OCONEE HIGH SCHOOL FOR OCONEE COUNTY SCHOOLS WATKINSVILLE, GEORGIA DATED: SEPTEMBER 14, 2018 CUNNINGHAM,

More information

VT8300 Series Installation Guide 24 Vac Low Voltage

VT8300 Series Installation Guide 24 Vac Low Voltage VT00 Series Installation Guide Low Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation Terminal Identification & Function Terminal identification Wiring Typical Applications

More information

INSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699)

INSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699) MILLENNIUM HEAD PRESSURE CONTROL KIT FOR LOW AMBIENT APPLICATIONS INSTALLATION INSTRUCTION Supersedes: 530.70-N.8Y (399) 530.70-N.8Y (99) HEAD PRESSURE CONTROL FOR 208/230 & 0V 25, 30 & 0 TON MILLENNIUM

More information

1 Digital input (24Vac or dry contact) Inputs

1 Digital input (24Vac or dry contact) Inputs Fan oil Thermostat Fan oil Thermostat Features: Attractive modern look with large LD and backlight Icons driven information and 1 line of text information 2 Pipes Analog, ON/OFF or Floating 4 Pipes Analog,

More information

EVERGREEN EM INSTALLATION GUIDE

EVERGREEN EM INSTALLATION GUIDE EVERGREEN INSTALLATION GUIDE A Regal Brand Genteq s Evergreen is designed to replace O X13 ECM motors quickly and easily with no programming required. Evergreen provides the same comfort, lower utility

More information

- Wiring Brochure Universal Reset Module 423e

- Wiring Brochure Universal Reset Module 423e - Wiring Brochure Universal Reset Module 4e W 4e 0/08 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications Rough In Wiring Rough-in wiring

More information

S ENSORLINK INSTALLATION MANUAL

S ENSORLINK INSTALLATION MANUAL S ENSORLINK INSTALLATION MANUAL The SensorLink Transmitter (#7610) and SensorLink Receiver (#7611) are designed to work with Davis Instruments Weather Monitor II and the Weather Wizard III to enable wireless

More information

User Manual. ProRF Encoder Transmitter & Receiver

User Manual. ProRF Encoder Transmitter & Receiver User Manual ProRF Encoder Transmitter & Receiver WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original

More information

R PROFLAME Instruction Book Collection

R PROFLAME Instruction Book Collection 9.956.028 R00 584 PROFLAME Instruction Book Collection 4-17 18-29 584 PROFLAME System 30-39 Appendix: DIP SWITCH NUMBER (0=ON 1=OFF) 40-41 4-17 Fig. 1 The SIT is a device that allows, in conjunction with

More information

Option Setting Level #1 Programming Chart For Standard Valves. Regeneration Time Example: 2:00 A.M. [ 2:00]

Option Setting Level #1 Programming Chart For Standard Valves. Regeneration Time Example: 2:00 A.M. [ 2:00] - V2.0 Option Setting Level #1 Programming Chart For Standard Valves Level #1 Note: 1. Push Program Button Once Per Display. 2. Option settings may be changed by pushing either the Up or Down Arrow Button.

More information

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration Table 1. Placing the Sensor in the Sensor Cradle Step Instruction Illustration 1. A. Check "U-shaped" Positioner. The number pointing towards the Sensor (1 or 2) must correspond with the Sensor's size.

More information

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor clear mode enter clear mode enter GE Sensing Introduction The GE Telaire Vaporstat 900 sensor measures in applications in the range of 0 to 0 F dew point. The sensor package is designed for wall mounting.

More information

User s Guide Instructions for Installation and Operation

User s Guide Instructions for Installation and Operation User s Guide Instructions for Installation and Operation 2.4 GHZ SPREAD SPECTRUM REMOTE CONTROLS Keyfob Transmitters Models KTX24SS1 KTXW24SS3 KTX24SS2 KTX24SS3 Wall Mount Models NTX24SS1 NTX24SS2 Remote

More information

Programmable Process Temperature Controller

Programmable Process Temperature Controller Programmable Process Temperature Controller www.maxitrol.com INSTALLATION GUIDE Warnings Inappropriate and/or improper installation, adjustment, alteration, service or maintenance can cause property damage,

More information

TC 204 Heating Controller

TC 204 Heating Controller TC 204 Heating Controller ver. 1.32-01 The TC204 is a multi-purpose heating controller with built-in programs for different types of heating systems. General Data Power requirement 24 volts ac, 2 va Inputs

More information

MODEL 421 Over/Under Motor Load Monitor

MODEL 421 Over/Under Motor Load Monitor MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart

More information

ETC Installation Guide

ETC Installation Guide Unison Echo Overview The Echo is a ceiling mounted sensor that utilizes passive infrared (PIR) technology, providing reliable vacancy and occupancy detection for lighting control. The sensor allows for

More information

Fan Coil Actuator FCA 2

Fan Coil Actuator FCA 2 Fan Coil Actuator FCA 2 FCA 2 4920210 Updated: Feb-16 (subject to changes) Page 1 of 89 Contents 1 Function description... 4 1.1 Operation and display... 5 1.2 Advantages of the FCA 2... 6 1.2.1 Special

More information

E-BUS Digital Room Sensor Technical Guide

E-BUS Digital Room Sensor Technical Guide E-BUS Digital Room Sensor Technical Guide TABLE OF CONTENTS OVERVIEW... 3 BASIC OPERATION... 4 Sensor Operation... 4 LED Operation... 4 MOUNTING AND WIRING... 5 Dimensions... 5 Environmental Requirements...

More information

AEROCONNECT 1B NA C Control manual

AEROCONNECT 1B NA C Control manual AEROCONNECT 1B NA 11.3 C 03-01 Control manual EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth 1. Sensor connections 1.6 Communication

More information

Communicative heating controller

Communicative heating controller UC100 Communicative heating controller Summary UC100 is a communicative room heating controller with one PWM output for control of a radiator or electrical heater. It can work autonomously, or in connection

More information

INTAC Microprocessor Humidifier Controller

INTAC Microprocessor Humidifier Controller PURE Humidifier Company Read and Save These Instructions INTAC Microprocessor Humidifier Controller Installation Instructions Operation and Maintenance Manual 002 % Power 68% Heaters 1 2 3 4 INTAC Humidifier

More information

ET Water SmartWorks Panel Installation Guide

ET Water SmartWorks Panel Installation Guide ET Water SmartWorks Panel Installation Guide You are installing a new piece of equipment that retrofits into an existing irrigation controller in order to create a weather-based irrigation control system.

More information

Rev RF Service Tool Operator s Guide

Rev RF Service Tool Operator s Guide 026-1703 Rev 0 7-23-01 RF Service Tool Operator s Guide 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The information contained in this

More information

SE7600F Series. RTU Terminal Equipment Controller with Modulating Heat. Installation Guide For Commercial HVAC Applications CONTENTS.

SE7600F Series. RTU Terminal Equipment Controller with Modulating Heat. Installation Guide For Commercial HVAC Applications CONTENTS. Room Controllers 01 RTU Terminal Equipment Controller with Modulating Heat For Commercial HVAC Applications CONTENTS Installation 2 Location 2 Installation 2 Operation Overview 3 Features overview 3 Model

More information

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION y GUIDE SPECIFICATIONS 407466-UGS-A-0508 SIMPICITY VAV (VARIABE AIR VOUME) Optional 15-25 Ton Packaged Product Comfort Control System CONTROS SPECIFICATIONS AND CONTRO POINT DATA MAP GENERA DESCRIPTION

More information

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description Home Automation, Inc. Omnistat2 RC-1000 and RC-2000 Communicating Thermostat Serial Protocol Description This document contains the intellectual property of Home Automation, Inc. (HAI). HAI authorizes

More information

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt.

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt. Quick Start Guide Backplate Backup Key Battery Cover Touchscreen Assembly Parts Strike Bolt Inside Assembly Thumbturn Reinforcement Plate Set Screw Reinforcement Screws Inside Assembly Screw Backplate

More information

Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A

Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A Installation Guide Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A 027R9966 ICAD 600A ICAD 600A-TS ICAD 1200A 027R9966 ICAD 600A / ICAD 600A-TS ICAD 1200A Fig. 1 Fig. 2 Note: When mounting the ICAD make

More information

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual THE HIGH PERFORMANCE COMPANY Series 70 Hold 1 sec. Hold 1 sec. FOR MORE INFORMATION ON THIS PRODUCT AND OTHER BRAY PRODUCTS PLEASE VISIT OUR WEBSITE www.bray.com Table of Contents 1. Definition of Terms.........................................2

More information

Intelligent Compact Controller

Intelligent Compact Controller TCY-T0121 Intelligent Compact Controller Features Temperature control for 2-pipe, 4-pipe HVAC systems. Temperature range from 40 to 140 C. 1 independent PI and On/Off control loop to control temperature.

More information

VT8600 Series User Interface Guide Rooftop Unit, Heatpump and Indoor Air Quality Controller

VT8600 Series User Interface Guide Rooftop Unit, Heatpump and Indoor Air Quality Controller 1 VT8600 Series User Interface Guide Rooftop Unit, Heatpump and Indoor Air Quality Controller Version 11 2 Table of Contents Section 1 Introduction 4 User and Integrator Screens 4 Disclaimer 5 HMI Display

More information

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 Manual-NEO_5003-4_1-17

More information

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs Photoelectrics, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs µ-processor controlled unit for up to 10 sets of photoelectric sensors Up to 10 independent outputs Self-diagnostic

More information

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder. Instruction Manual TPSRF31 (181430) - BOSS TM Electronic RF Roomstat Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

More information

Wireless Analog Output Modules

Wireless Analog Output Modules Overview and Product Identification Wireless Analog s Analog s receive data from a BAPI 418 MHz receiver or 900 MHz receiver through a four-wire RS 485 bus. Up to 127 different Analog s can be connected

More information

Manual BC20 Control Service Guide

Manual BC20 Control Service Guide Manual BC20 Control Service Guide To Access the following menus, with the in the OFF mode, press and hold the upper encoder (Timer Knob) until "0000" appears. Then turn the encoder till the first number

More information

NEW DIGITAL PUMP LOAD CONTROL

NEW DIGITAL PUMP LOAD CONTROL NEW DIGITAL PUMP LOAD CONTROL Power sensor monitors true motor power Waterproof & rugged, large red LED display Compact enclosure with flexible fittings Easy front panel keypad set up Low and high setpoint

More information

Metasys Zoning Package Commissioning

Metasys Zoning Package Commissioning Technical Bulletin Issue Date 11/01/01 TECHNICAL BULLETIN Metasys Zoning Package Commissioning Metasys Zoning Package Commissioning...2 Introduction... 2 Key Concepts... 3 HVAC PRO Software...3 Configuration

More information

LT3000 ULTRASONIC LEVEL TRANSMITTER

LT3000 ULTRASONIC LEVEL TRANSMITTER LT3000 ULTRASONIC LEVEL TRANSMITTER Owner s Manual Specifications Installation Calibration Troubleshooting Warranty Drawings Distributed By: iprocessmart.com 14262 Doolittle Drive San Leandro, CA 94577

More information

The Ins and Outs of Basic. A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate.

The Ins and Outs of Basic. A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate. Part 3 The Ins and Outs of Basic Sch ematic Symbols A practical approach to reading and understanding the schematic diagrams used to explain how HVACR systems operate. B y H o w a r d L. P e m p e r, C

More information

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

ECB-103 BACnet B-ASC 10-Point Programmable Controllers D a t a s h e e t BACnet B-ASC 10-Point Programmable Controllers Overview The is a microprocessor-based programmable controller designed to control terminal units such as fan coil unit, heat pump unit,

More information

Wireless Room Thermostat Installation and Operation Y6630D1007

Wireless Room Thermostat Installation and Operation Y6630D1007 Wireless Room Thermostat Installation and Operation Y6630D1007 General safety instructions Contents 1. General safety instructions... 3 1.1. Commissioning the relay module HC60NG... 3 2. Overview... 4

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information