TransPowr ACSS Bare Overhead Conductor Aluminum Conductor Steel-Supported Concentric-Lay-Stranded

Size: px
Start display at page:

Download "TransPowr ACSS Bare Overhead Conductor Aluminum Conductor Steel-Supported Concentric-Lay-Stranded"

Transcription

1 20/7 22/7 24/7 26/7 30/7 30/19 54/7 54/19 45/7 72/7 76/19 84/19 Product Construction: Complete Conductor: ACSS is a composite concentric-lay-stranded cable. ACSS conductors are manufactured in accordance with the latest issue of ASTM B856. The steel strands form the central core of the cable, around which is stranded one or more layers of aluminum 1350-O wires. The O temper of the aluminum, a fully annealed or soft temper, causes most or all of the mechanical load on ACSS to be carried by the steel. Standard ACSS designs are manufactured with regular-strength Class A zinc-5% aluminum mischmetal alloy-coated steel core (/MA2). The steel core may consist of 7, 19, 37 or more wires. Features and Benefits: ACSS conductors are similar to conventional ACSR with some very important additional advantages. ACSS can operate continuously at high temperatures up to 250 C without damage, allowing for a significant increase in conductor current-carrying capacity. ACSS sags less under emergency electrical loadings than ACSR, it is self-damping, and its final sags are not affected by long-term creep of the aluminum. Applications: Aluminum conductor steel-supported (ACSS) is used for overhead transmission lines. It is especially useful in reconductoring applications requiring increased current with existing tensions and clearances; new line applications where structures can be economized due to reduced sag; new line applications requiring high emergency loadings; and lines where aeolian vibration is a problem. Options: High-strength Class A zinc-5% aluminum mischmetal alloy-coated steel core (/MA3 to ASTM B803) Extra-high-strength Class A zinc-5% aluminum mischmetal alloy-coated steel core (/MA4 to ASTM B958) Ultra-high-strength Class A zinc-5% aluminum mischmetal alloy-coated steel core (/MA5 to ASTM B958) Aluminum-clad steel core (/AW) see ACSS/AW catalog section Options (cont d): 250 C operating temperature rating utilizing either the zinc-5% aluminum mischmetal alloy-coated steel core wires or the aluminum-clad steel core wires Trapezoidal-shaped aluminum strands (/TW) see ACSS/TW catalog section Non-specular surface finish (/NS) For more information, or information on other conductor sizes, designs and/or specific installation requirements not shown in the tables, contact your General Cable sales representative or

2 Electric Utility ACSS, CONCENTRIC-LAY-STRANDED (MECHANICAL PROPERTIES) STRANDING CROSS-SECTION APPROX. WEIGHT PERCENT RATED STRENGTH LB/1000 FT (2) BY MASS LBS STANDARD PACKAGES (3) AL STEEL TOTAL AL O.D. INCHES TOTAL AL STEEL AL STEEL GA2 OR MA2 GA3 OR GA5 OR REEL MA3 (HS) MA5 (UHS) DESIGNATION POUNDS WEIGHT LENGTH FEET Spoonbill/ACSS x x RM Scaup/ACSS x x RM Partridge/ACSS x x RM Junco/ACSS x x RM Ostrich/ACSS x x RM Trogon/ACSS x x RM Woodcock/ACSS x x RMT RM Widgeon/ACSS x x RMT RM Linnet/ACSS x x RMT RM Oriole/ACSS x x RM Ptarmigan/ACSS x x RM Stork/ACSS x x RMT RM Brant/ACSS x x RMT RM Ibis/ACSS x x RMT RM Lark/ACSS x x RM Tailorbird/ACSS x x RM Toucan/ACSS x x RMT RM Flicker/ACSS x x RMT RM Hawk/ACSS x x RMT RM Hen/ACSS x x RM Heron/ACSS x x RM Tody/ACSS x x RM Sapsucker/ACSS x x RMT RM Parakeet/ACSS x x RMT RM Dove/ACSS x x RMT RM Eagle/ACSS x x RM Peacock/ACSS x x RMT RM Squab/ACSS x x RMT RM Wood Duck/ACSS x x RM Teal/ACSS x x RMT RM Turacos/ACSS x x RMT RM Goldfinch/ACSS x x RMT RMT RM Rook/ACSS x x RMT RMT RM (2) Due to rounding, total values may be slightly greater or slightly less than the sum of the component values. (3) Weights shown are for conductor only and do not include the reel. Normal length and shipping tolerances apply. Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means mass. 123

3 ACSS, CONCENTRIC-LAY-STRANDED (ELECTRICAL PROPERTIES) STRANDING CROSS-SECTION RESISTANCE (4) OHMS/1000 FT AMPACITY (5) O.D. DC AC AC AC AL STEEL TOTAL AL C 75 C 200 C GEOMETRIC MEAN RADIUS FT INDUCTIVE OHM/1000 FT (6) CAPACITIVE MEGAOHM 1000 FT (6) Spoonbill/ACSS x x Scaup/ACSS x x Partridge/ACSS x x Junco/ACSS x x Ostrich/ACSS x x Trogon/ACSS x x Woodcock/ACSS x x Widgeon/ACSS x x Linnet/ACSS x x Oriole/ACSS x x Ptarmigan/ACSS x x Stork/ACSS x x Brant/ACSS x x Ibis/ACSS x x Lark/ACSS x x Tailorbird/ACSS x x Toucan/ACSS x x Flicker/ACSS x x Hawk/ACSS x x Hen/ACSS x x Heron/ACSS x x Tody/ACSS x x Sapsucker/ACSS x x Parakeet/ACSS x x Dove/ACSS x x Eagle/ACSS x x Peacock/ACSS x x Squab/ACSS x x Wood Duck/ACSS x x Teal/ACSS x x Turacos/ACSS x x Goldfinch/ACSS x x Rook/ACSS x x (1) Code words shown denote ACSS with regular-strength Class A zinc-5% aluminum mischmetal alloy-coated steel core (/MA2). See the Options section to find the appropriate code word modifier designation for alternative design options. (4) Based on a conductivity of 63.0% IACS at 20 C for aluminum and 8% IACS at 20 C for the steel core. AC resistance for single-layer and three-layer designs approximates the effects of core magnetization. To convert to ohms/mile, multiply by To convert to ohms/km, multiply by (5) Based on the given conductor temperature at 60 Hz and the following conditions: 25 C ambient temperature, 2 ft/sec crosswind (90 to conductor), 0.5 coefficient of emissivity, 0.5 coefficient of absorbtivity, 30 northern latitude, sea level elevation, 90 azimuth of line (East-West), clear atmosphere, and a date and time of noon on July 1(resulting in 96.0 W/ft² of solar and sky radiated heat). Actual ampacity will differ based on local conditions. For specific ampacities, please contact your General Cable sales representative. (6) Values for inductive reactance and capacitive reactance are expressed in terms of a 1 ft radius. 124

4 Electric Utility ACSS, CONCENTRIC- LAY-STRANDED (MECHANICAL PROPERTIES) STRANDING CROSS-SECTION APPROX. WEIGHT PERCENT RATED STRENGTH LB/1000 FT (2) BY MASS LBS STANDARD PACKAGES (3) O.D. GA2 OR GA3 OR GA5 OR REEL WEIGHT LENGTH AL STEEL TOTAL AL INCHES TOTAL AL STEEL AL STEEL MA2 MA3 (HS) MA5 (UHS) DESIGNATION POUNDS FEET Grosbeak/ACSS x x RMT RMT RM Scoter/ACSS x x RMT RM Egret/ACSS x x RMT RMT RM Flamingo/ACSS x x RMT RMT RM Gannet/ACSS x x RMT RMT RM Stilt/ACSS x x RMT RMT RM Starling/ACSS x x RMT RMT RM Redwing/ACSS x x RMT RMT RM Macaw/ACSS x x RMT RM Turbit/ACSS x x RMT RM Tern/ACSS x x RMT RMT RM Puffin/ACSS x x RMT RMT RM Cuckoo/ACSS x x RMT RMT RM Condor/ACSS x x RMT RMT Drake/ACSS x x RMT RMT RM Mallard/ACSS x x RMT RMT RM Ruddy/ACSS x x RMT RMT RM Canary/ACSS x x RMT RMT Phoenix/ACSS x x RMT RM Corncrake/ACSS x x RMT RM (2) Due to rounding, total values may be slightly greater or slightly less than the sum of the component values. (3) Weights shown are for conductor only and do not include the reel. Normal length and shipping tolerances apply. Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means mass. 125

5 ACSS, CONCENTRIC-LAY-STRANDED (ELECTRICAL PROPERTIES) STRANDING CROSS-SECTION RESISTANCE (4) OHMS/1000 FT AMPACITY (5) O.D. DC AC AC AC AL STEEL TOTAL AL C 75 C 200 C GEOMETRIC MEAN RADIUS FT INDUCTIVE OHM/1000 FT (6) CAPACITIVE MEGAOHM 1000 FT (6) Grosbeak/ACSS x x Scoter/ACSS x x Egret/ACSS x x Flamingo/ACSS x x Gannet/ACSS x x Stilt/ACSS x x Starling/ACSS x x Redwing/ACSS x x Macaw/ACSS x x Turbit/ACSS x x Tern/ACSS x x Puffin/ACSS x x Cuckoo/ACSS x x Condor/ACSS x x Drake/ACSS x x Mallard/ACSS x x Ruddy/ACSS x x Canary/ACSS x x Phoenix/ACSS x x Corncrake/ACSS x x (1) Code words shown denote ACSS with regular-strength Class A zinc-5% aluminum mischmetal alloy-coated steel core (/MA2). See the Options section to find the appropriate code word modifier designation for alternative design options. (4) Based on a conductivity of 63.0% IACS at 20 C for aluminum and 8% IACS at 20 C for the steel core. AC resistance for single-layer and three-layer designs approximates the effects of core magnetization. To convert to ohms/mile, multiply by To convert to ohms/km, multiply by (5) Based on the given conductor temperature at 60 Hz and the following conditions: 25 C ambient temperature, 2 ft/sec crosswind (90 to conductor), 0.5 coefficient of emissivity, 0.5 coefficient of absorbtivity, 30 northern latitude, sea level elevation, 90 azimuth of line (East-West), clear atmosphere, and a date and time of noon on July 1 (resulting in 96.0 W/ft² of solar and sky radiated heat). Actual ampacity will differ based on local conditions. For specific ampacities, please contact your General Cable sales representative. (6) Values for inductive reactance and capacitive reactance are expressed in terms of a 1 ft radius. 126

6 Electric Utility ACSS, CONCENTRIC-LAY-STRANDED (MECHANICAL PROPERTIES) STRANDING CROSS-SECTION APPROX. WEIGHT PERCENT RATED STRENGTH LB/1000 FT (2) BY MASS LBS STANDARD PACKAGES (3) O.D. GA2 OR GA3 OR GA5 OR REEL WEIGHT LENGTH AL STEEL TOTAL AL INCHES TOTAL AL STEEL AL STEEL MA2 MA3 (HS) MA5 (UHS) DESIGNATION POUNDS FEET Rail/ACSS x x RMT RMT RM Towhee/ACSS x x RMT RMT RMT Redbird/ACSS x x RMT RMT Cardinal/ACSS x x RMT RMT Canvasback/ x x RMT ACSS RMT RM Snowbird/ACSS x x RMT RM Ortolan/ACSS x x RMT RMT RM Whooper/ACSS x x RMT RMT RM Curlew/ACSS x x RMT RMT Avocet/ACSS x x RMT RMT RM Bluejay/ACSS x x RMT RMT RM Bullfinch/ACSS x x RMT RMT RMT Finch/ACSS x x RMT RMT Oxbird/ACSS x x RMT RMT RM Bunting/ACSS x x RMT RMT RM Cormorant/ACSS x x RMT RMT RMT Grackle/ACSS x x RMT RMT Scissortail/ACSS x x RMT RMT RM Bittern/ACSS x x RMT RMT RM (2) Due to rounding, total values may be slightly greater or slightly less than the sum of the component values. (3) Weights shown are for conductor only and do not include the reel. Normal length and shipping tolerances apply. Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means mass. 127

7 ACSS, CONCENTRIC-LAY-STRANDED (ELECTRICAL PROPERTIES) STRANDING CROSS-SECTION RESISTANCE (4) OHMS/1000 FT AMPACITY (5) O.D. DC AC AC AC AL STEEL TOTAL AL C 75 C 200 C GEOMETRIC MEAN RADIUS FT INDUCTIVE OHM/1000 FT (6) CAPACITIVE MEGAOHM 1000 FT (6) Rail/ACSS x x Towhee/ACSS x x Redbird/ACSS x x Cardinal/ACSS x x Canvasback/ x x ACSS Snowbird/ACSS x x Ortolan/ACSS x x Whooper/ACSS x x Curlew/ACSS x x Avocet/ACSS x x Bluejay/ACSS x x Bullfinch/ACSS x x Finch/ACSS x x Oxbird/ACSS x x Bunting/ACSS x x Cormorant/ACSS x x Grackle/ACSS x x Scissortail/ACSS x x Bittern/ACSS x x (4) Based on a conductivity of 63.0% IACS at 20 C for aluminum and 8% IACS at 20 C for the steel core. AC resistance for single-layer and three-layer designs approximates the effects of core magnetization. To convert to ohms/mile, multiply by To convert to ohms/km, multiply by (5) Based on the given conductor temperature at 60 Hz and the following conditions: 25 C ambient temperature, 2 ft/sec crosswind (90 to conductor), 0.5 coefficient of emissivity, 0.5 coefficient of absorbtivity, 30 northern latitude, sea level elevation, 90 azimuth of line (East-West), clear atmosphere, and a date and time of noon on July 1 (resulting in 96.0 W/ft² of solar and sky radiated heat). Actual ampacity will differ based on local conditions. For specific ampacities, please contact your General Cable sales representative. (6) Values for inductive reactance and capacitive reactance are expressed in terms of a 1 ft radius. 128

8 Electric Utility ACSS, CONCENTRIC-LAY-STRANDED (MECHANICAL PROPERTIES) STRANDING CROSS-SECTION APPROX. WEIGHT PERCENT RATED STRENGTH LB/1000 FT (2) BY MASS LBS STANDARD PACKAGES (3) O.D. GA2 OR GA3 OR GA5 OR REEL WEIGHT LENGTH AL STEEL TOTAL AL INCHES TOTAL AL STEEL AL STEEL MA2 MA3 (HS) MA5 (UHS) DESIGNATION POUNDS FEET Diver/ACSS x x RMT RMT RMT Pheasant/ACSS x x RMT RMT Ringdove/ACSS x x RMT RMT RM Dipper/ACSS x x RMT RMT RM none x x RMT RMT RMT Martin/ACSS x x RMT RMT Popinjay/ACSS x x RMT RMT RM Bobolink/ACSS x x RMT RMT RM Wagtail/ACSS x x RMT RMT RMT Plover/ACSS x x RMT RMT Nuthatch/ACSS x x RMT RMT RM Parrot/ACSS x x RMT RMT Ratite/ACSS x x RMT RMT RM Lapwing/ACSS x x RMT RMT RM Hornbill/ACSS x x RMT RMT RMT Falcon/ACSS x x RMT RMT Chukar/ACSS x x RMT Seahawk/ACSS x x RMT Mockingbird/ACSS x x RMT Roadrunner/ACSS x x RMT Bluebird/ACSS x x RMT Kiwi/ACSS x x RMT Thrasher/ACSS x x RMT Joree/ACSS x x RMT (2) Due to rounding, total values may be slightly greater or slightly less than the sum of the component values. (3) Weights shown are for conductor only and do not include the reel. Normal length and shipping tolerances apply. Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means mass. 129

9 ACSS, CONCENTRIC-LAY-STRANDED (ELECTRICAL PROPERTIES) STRANDING CROSS-SECTION RESISTANCE (4) OHMS/1000 FT AMPACITY (5) O.D. DC AC AC AC AL STEEL TOTAL AL C 75 C 200 C GEOMETRIC MEAN RADIUS FT INDUCTIVE OHM/1000 FT (6) CAPACITIVE MEGAOHM 1000 FT (6) Diver/ACSS x x Pheasant/ACSS x x Ringdove/ACSS x x Dipper/ACSS x x none x x Martin/ACSS x x Popinjay/ACSS x x Bobolink/ACSS x x Wagtail/ACSS x x Plover/ACSS x x Nuthatch/ACSS x x Parrot/ACSS x x Ratite/ACSS x x Lapwing/ACSS x x Hornbill/ACSS x x Falcon/ACSS x x Chukar/ACSS x x Seahawk/ACSS x x Mockingbird/ACSS x x Roadrunner/ACSS x x Bluebird/ACSS x x Kiwi/ACSS x x Thrasher/ACSS x x Joree/ACSS x x (4) Based on a conductivity of 63.0% IACS at 20 C for aluminum and 8% IACS at 20 C for the steel core. AC resistance for single-layer and three-layer designs approximates the effects of core magnetization. To convert to ohms/mile, multiply by To convert to ohms/km, multiply by (5) Based on the given conductor temperature at 60 Hz and the following conditions: 25 C ambient temperature, 2 ft/sec crosswind (90 to conductor), 0.5 coefficient of emissivity, 0.5 coefficient of absorbtivity, 30 northern latitude, sea level elevation, 90 azimuth of line (East-West), clear atmosphere, and a date and time of noon on July 1 (resulting in 96.0 W/ft² of solar and sky radiated heat). Actual ampacity will differ based on local conditions. For specific ampacities, please contact your General Cable sales representative. (6) Values for inductive reactance and capacitive reactance are expressed in terms of a 1 ft radius. 130

TransPowr ACSR/TW Bare Overhead Conductor Trapezoidal Aluminum Conductor Steel-Reinforced Concentric-Lay-Stranded

TransPowr ACSR/TW Bare Overhead Conductor Trapezoidal Aluminum Conductor Steel-Reinforced Concentric-Lay-Stranded TransPowr Bare Overhead Conductor 18/7 20/7 21/7 22/7 36/7 36/19 38/19 39/19 64/19 Product Construction: Complete Conductor: TransPowr is a trapezoidal aluminum conductor steel-reinforced concentric-lay-stranded

More information

TransPowr AAC Bare Overhead Conductor All-Aluminum 1350 Conductor Concentric-Lay-Stranded

TransPowr AAC Bare Overhead Conductor All-Aluminum 1350 Conductor Concentric-Lay-Stranded 7 19 37 61 91 Product Construction: Complete Conductor: Bare all-aluminum 1350 conductors (AAC) are concentric-lay-stranded conductors, consisting of one or more layers of wire wrapped helically around

More information

TransPowr ACSR Bare Overhead Conductor Aluminum Conductor Steel-Reinforced Concentric-Lay-Stranded

TransPowr ACSR Bare Overhead Conductor Aluminum Conductor Steel-Reinforced Concentric-Lay-Stranded 6/1 7/1 18/1 36/1 12/7 24/7 26/7 30/7 45/7 72/7 54/7 30/19 54/19 76/19 84/19 Product Construction: Complete Conductor: ACSR is a composite concentric-lay-stranded conductor. ACSR conductors are manufactured

More information

TransPowr AAC Bare Overhead Conductor All-Aluminum 1350 Conductor Concentric-Lay-Stranded

TransPowr AAC Bare Overhead Conductor All-Aluminum 1350 Conductor Concentric-Lay-Stranded Electric Utility TransPowr AAC Bare Overhead Conductor All-Aluminum 1350 Conductor Concentric-Lay-Stranded Overhead Conductors 7 19 37 61 91 Product Construction: Complete Conductor: Bare all-aluminum

More information

TransPowr ACSR/SD Bare Overhead Conductor Self-Damping Aluminum Conductor Steel-Reinforced Concentric-Lay-Stranded

TransPowr ACSR/SD Bare Overhead Conductor Self-Damping Aluminum Conductor Steel-Reinforced Concentric-Lay-Stranded 2-Layer SDC 3-Layer SDC Product Construction: Complete Conductor: SR/SD conductors are manufactured with two layers of 1350 H19 trapezoidal-shaped aluminum wires concentrically stranded around a steel

More information

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties 2. CONDUCTORS 2.1 Strand Types 2.1.1 Concentric Strand 7 2.1.2 Bunch Strand 7 2.1.3 Rope Strand 8 2.1.4 Sector Conductor 8 2.1.5 Segmental Conductor 8 2.1.6 Annular Conductor 8 2.1.7 Compact Strand 8 2.1.8

More information

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS NOMENCLATURE Crossover Marks: Indicate starting point for application. Gritted and Neoprene Dipped Legs: Grit is permanently embedded in a coating of neoprene. GENERAL RECOMMENDATIONS Coated Dead-ends:

More information

RUS Accepted NOMENCLATURE GENERAL RECOMMENDATIONS (440) EN-CA

RUS Accepted NOMENCLATURE GENERAL RECOMMENDATIONS (440) EN-CA NOMENCLATURE RUS Accepted Crossover Marks: Indicate starting point for application. Color Code and Length: Assist in identification of conductor size, corresponding to tabular information appearing on

More information

Aluminum-clad Steel Wire

Aluminum-clad Steel Wire AS Wire/GS Wire AS WIRE Aluminum-clad Steel Wire GS WIRE Galvanized Steel Wire Made in the U.S.A. Development of Aluminumclad Steel (AS) Wire Conex Cable, LLC, under the original name of Conex, started

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

SELF DAMPING TEST ON 1020 KCMIL ACCC/TW CONDUCTOR FOR COMPOSITE TECHNOLOGY CORPORATION

SELF DAMPING TEST ON 1020 KCMIL ACCC/TW CONDUCTOR FOR COMPOSITE TECHNOLOGY CORPORATION To: Dave Bryant Composite Technology Corporation 2026 McGaw Avenue Irvine, CA 92614 USA SELF DAMPING TEST ON 1020 KCMIL ACCC/TW CONDUCTOR FOR COMPOSITE TECHNOLOGY CORPORATION Kinectrics North America Inc.

More information

Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors 1

Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors 1 Designation: B 258 02 Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors 1 This standard is issued under the

More information

Slack Span Dead-end. Slack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE 14-23

Slack Span Dead-end. Slack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE 14-23 NOMENCLATURE Dead-end Material Helical Leg Section: Aluminum covered steel. An aluminum alloy version is available for corrosive environment. Contact PLP. Crossover Marks: Indicates starting point for

More information

Conductor Splice NOMENCLATURE GENERAL RECOMMENDATIONS (440)

Conductor Splice NOMENCLATURE GENERAL RECOMMENDATIONS (440) Conductor Splice NOMENCLATURE Sub-Sets: Individual rods assembled and gritted into groups (subsets), corresponding to tabular information appearing on catalog page. Center Mark: Establishes recommended

More information

KINECTRICS NORTH AMERICA INC. TEST REPORT FOR 3M COMPANY TO COMPARE THE LIGHTNING PERFORMANCE OF ACCR TO ACSR CONDUCTORS

KINECTRICS NORTH AMERICA INC. TEST REPORT FOR 3M COMPANY TO COMPARE THE LIGHTNING PERFORMANCE OF ACCR TO ACSR CONDUCTORS To: Colin McCullough 3M Composite Conductor Program 2465 Lexington Ave. South Mendota Heights, MN 5512 USA KINECTRICS NORTH AMERICA INC. TEST REPORT FOR 3M COMPANY TO COMPARE THE LIGHTNING PERFORMANCE

More information

Installation requirements

Installation requirements Installation requirements for SUNNY CENTRAL 500U 1 Contents This document describes the requirements which have to be observed for the installation site of the Sunny Central 500U. The installation and

More information

Conductor Splice NOMENCLATURE GENERAL RECOMMENDATIONS (440) EN-CA

Conductor Splice NOMENCLATURE GENERAL RECOMMENDATIONS (440) EN-CA NOMENCLATURE Sub-Sets: Individual rods assembled and gritted into groups (subsets), corresponding to tabular information appearing on catalog page. Center Mark: Establishes recommended alignment of rods

More information

Field Instrument Cable. Electrical Noise

Field Instrument Cable. Electrical Noise Field Instrument Cable Electrical Noise 1 Electrical Noise Instrument Cables are Susceptible to 4 Types of Noise: Static Magnetic Cross-Talk Common Mode 2 Static Noise Static Noise is caused by an electric

More information

MidAmerican Energy Company 69 kv Facility Ratings Methodology

MidAmerican Energy Company 69 kv Facility Ratings Methodology MidAmerican Energy Company 69 kv Facility Ratings Methodology Version 1.0 Issued by: Luke Erichsen Reviewed by: Tom Mielnik Last Reviewed: 8/29/2012 1 1.0 Scope: This document provides MidAmerican Energy

More information

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology

More information

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

FACILITY RATINGS METHOD TABLE OF CONTENTS

FACILITY RATINGS METHOD TABLE OF CONTENTS FACILITY RATINGS METHOD TABLE OF CONTENTS 1.0 PURPOSE... 2 2.0 SCOPE... 3 3.0 COMPLIANCE... 4 4.0 DEFINITIONS... 5 5.0 RESPONSIBILITIES... 7 6.0 PROCEDURE... 8 6.4 Generating Equipment Ratings... 9 6.5

More information

COPPERCLAD STEEL WIRE. Dead Soft Annealed Jacketed High Strength. Extra High Strength Composite Conductors Guy Wire

COPPERCLAD STEEL WIRE. Dead Soft Annealed Jacketed High Strength. Extra High Strength Composite Conductors Guy Wire COPPERCLAD STEEL WIRE Dead Soft Annealed Jacketed High Strength Extra High Strength Composite Conductors Guy Wire Founded in 1984, AFL is an international manufacturer providing end-to-end solutions to

More information

Standard Specification for Copper-Clad Steel Wire for Electronic Application 1

Standard Specification for Copper-Clad Steel Wire for Electronic Application 1 Designation: B 45 0 Standard Specification for Copper-Clad Steel Wire for Electronic Application 1 This standard is issued under the fixed designation B 45; the number immediately following the designation

More information

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology For NERC Standard FAC-008 and FAC-009 Issued by: Dan Custer Reviewed by: Tom Mielnik Version 2.7 1 1.0 Scope: This document provides

More information

Standards Update Notice (SUN) Issued: June 6, 2017

Standards Update Notice (SUN) Issued: June 6, 2017 Standard Information Standard Number: UL 758 Standard Name: Standard for Safety for Appliance Wiring Material Standard Edition and Issue Date: 3 rd Edition Dated May 2, 2014 Date of Revisions: 2 nd Ed.

More information

Parkers. Tolerances on dimensions

Parkers. Tolerances on dimensions Aluminium and aluminium alloys - Extruded rod/bar, tube and pro les Alloy groups The division into Group I and Group II of the most commonly used general engineering alloys is specified in table 1. (Corresponding

More information

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR C240-NFSM-3M Product Classification Brand Product Series Product Type CNT Jumper with interface types N Female and SMA Male, 3m CNT Braided cable assembly General Specifications Body Style, Connector A

More information

Technical Information Handbook

Technical Information Handbook Technical Information Handbook Wire and Cable Fifth Edition Copyright 2018 Trademarks and Reference Information The following registered trademarks appear in this handbook: Alumel is a registered trademark

More information

Canadian OSP Copper I-1. Table of Contents

Canadian OSP Copper I-1. Table of Contents Canadian OSP Copper Premises Copper Table of Contents CELFIL BJBB, BJAB, BJMB and BJTB................................. I-2 Canadian ALPETH BHBB, BHAB, BKMB and BKTB.................... I-4 SEALPAP BHBF,

More information

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic

More information

SIMpull THHN, it slips and slides - all with NoLube.

SIMpull THHN, it slips and slides - all with NoLube. SOUTHWIRE S SIMpull THHN Southwire maintains its goal of revolutionizing the wire industry by providing its consumers with a product that is not only SIMpull but also requires NoLube. SIMpull THHN is a

More information

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology For NERC Standard FAC-008-3 Version 3.4 1 Contents 1. Scope... 3 2. Establishment and Communication of Facility Ratings:... 3 2.1.

More information

ROCHESTER PUBLIC UTILITIES FACILITY RATINGS METHODOLOGY FOR TRANSMISSION, SUBSTATION, & GENERATION EQUIPMENT

ROCHESTER PUBLIC UTILITIES FACILITY RATINGS METHODOLOGY FOR TRANSMISSION, SUBSTATION, & GENERATION EQUIPMENT ROCHESTER PUBLIC UTILITIES FACILITY RATINGS METHODOLOGY FOR TRANSMISSION, SUBSTATION, & GENERATION EQUIPMENT Page 1 of 8 The document describes the current methodology used for developing facility ratings

More information

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications C400-TMTM-30-X Product Classification Brand Product Series Product Type CNT-400-FR CNT Jumper with interface types TNC Male and TNC Male, 9.14 m CNT CNT-400 Braided cable assembly General Specifications

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like

More information

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2 Engineering Specification Electrical Networks MESP 130400-04 TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/0.70 100mm 2 Version: 2 Issued: February 2016 Owner: Engineering

More information

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another.

PRELIMINARIES. Generators and loads are connected together through transmission lines transporting electric power from one place to another. TRANSMISSION LINES PRELIMINARIES Generators and loads are connected together through transmission lines transporting electric power from one place to another. Transmission line must, therefore, take power

More information

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR C400-UMUM-100 Product Classification Brand Product Series Product Type CNT Jumper with interface types UHF Male and UHF Male, 30.48 m CNT Braided cable assembly General Specifications Body Style, Connector

More information

1 Formula 1.1 Rules of Thumb 2 Table of AWG wire sizes 3 Pronunciation 4 See also 5 References 6 Further reading 7 External links

1 Formula 1.1 Rules of Thumb 2 Table of AWG wire sizes 3 Pronunciation 4 See also 5 References 6 Further reading 7 External links 1 of 8 6/1/2010 6:57 PM From Wikipedia, the free encyclopedia American wire gauge (AWG), also known as the Brown & Sharpe wire gauge, is a standardized wire gauge system used since 1857 predominantly in

More information

Review 6. unlike poles cause the magnets to attract. like poles cause the magnets to repel.

Review 6. unlike poles cause the magnets to attract. like poles cause the magnets to repel. Review 6 1. The two characteristics of all magnets are: they attract and hold Iron, and, if free to move, they will assume roughly a south - north position. 2. Lines of flux always leave the north pole

More information

C400-NMTM-1M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

C400-NMTM-1M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR C400-NMTM-1M Product Classification Brand Product Series Product Type CNT-400 CNT Jumper with interface types N Male and TNC Male, 1m CNT CNT-400 Braided cable assembly General Specifications Body Style,

More information

Design Considerations

Design Considerations Design Considerations Ferrite beads provide a simple, economical method for attenuating high frequency noise or oscillations. By slipping a bead over a wire, a RF choke or suppressor is produced which

More information

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 75 OHMS, LOW NOISE, LOW SMOKE, ENHANCED INSULATION RESISTANCE

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 75 OHMS, LOW NOISE, LOW SMOKE, ENHANCED INSULATION RESISTANCE INCH-POUND MIL-DTL-17/234 28 May 2016 DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 75 OHMS, LOW NOISE, LOW SMOKE, ENHANCED INSULATION RESISTANCE This specification is approved

More information

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...

More information

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2 Engineering Specification Electrical Networks MESP 130400-07 TECHNICAL SPECIFICATION FOR Version: 1 Issued: February 2017 Owner: Engineering Division Approved By: Andrew Russack Head of Engineering (Electrical)

More information

C195-SMQM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

C195-SMQM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR C195-SMQM-3M Product Classification Brand Product Series Product Type CNT-195 CNT Jumper with interface types SMA Male and QMA Male, 3M CNT CNT-195 Braided cable assembly General Specifications Body Style,

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics

More information

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, SEMIRIGID, COAXIAL, SEMI-AIR-DIELECTRIC,.875 TO INCHES OUTSIDE DIAMETER, 50 OHMS

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, SEMIRIGID, COAXIAL, SEMI-AIR-DIELECTRIC,.875 TO INCHES OUTSIDE DIAMETER, 50 OHMS INCH-POUND MIL-DTL-22931/11B 21 August 2013 SUPERSEDING MIL-C-22931/11A 20 January 1972 DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, SEMIRIGID, COAXIAL, SEMI-AIR-DIELECTRIC,.875 TO 1.005 INCHES

More information

LTE high-performance coaxial cables (RG replacement)

LTE high-performance coaxial cables (RG replacement) LTE high-performance coaxial cables (RG replacement) Center Conductor: See table below. Dielectric: LTE (extruded low-density PTFE) or low density / composite. Inner Shield: 875-892: None. 900-142: Flat

More information

TRANSMISSION FACILITIES...7

TRANSMISSION FACILITIES...7 Table of Contents 1. INTRODUCTION...4 1.1. Objective... 4 1.2. NERC FAC-008 Compliance... 4 1.3. Seminole s Normal Rating... 5 1.4. Seminole s Four-Hour Rating... 5 1.5. Seminole s Emergency Rating...

More information

EE 340 Transmission Lines. Spring 2012

EE 340 Transmission Lines. Spring 2012 EE 340 Transmission Lines Spring 2012 Physical Characteristics Overhead lines An overhead transmission line usually consists of three conductors or bundles of conductors containing the three phases of

More information

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2 Engineering Specification Electrical TECHNICAL SPECIFICATION FOR CONTACT WIRE HARD-DRAWN COPPER 161mm2 Version: 2 Issued: May 2018 Owner: Engineering Approved by: Andrew Russack, Head of Engineering Electrical

More information

DLO Flexible Power Cable

DLO Flexible Power Cable Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C

More information

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified. 907.01 Section 907. FENCING MATERIALS 907.01 General Requirements. Materials for use in fencing property, right-of-way and other installations must comply with this section. 907.02 Testing. Material testing

More information

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2 Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/2.14 70mm 2 Version: 1 Issued: January 2015 Owner: Engineering Division Approved By: Pat

More information

Ranch, Home and Garden

Ranch, Home and Garden DAVIS WIRE Ranch Hand Gold Brand Silverado Galfan Fencing Products Ranch, Home and Garden Made in the USA Field Fencing Hinge Joint Field Fence The flexible hinge joint knot gives our woven field fence

More information

DETAIL SPECIFICATION SHEET CONNECTORS AND ASSEMBLIES, ELECTRICAL, AIRCRAFT GROUNDING: TYPE IV JUMPER CABLE ASSEMBLY, LEAD, ELECTRICAL

DETAIL SPECIFICATION SHEET CONNECTORS AND ASSEMBLIES, ELECTRICAL, AIRCRAFT GROUNDING: TYPE IV JUMPER CABLE ASSEMBLY, LEAD, ELECTRICAL INCH-POUN 10 June 2015 SUPRSING MIL-TL-83413/8 w/amendment 1 30 July 2014 TAIL SPCIFICATION SHT CONNCTORS AN ASSMBLIS, LCTRICAL, AIRCRAFT GROUNING: TYP IV JUMPR CABL ASSMBLY, LA, LCTRICAL This specification

More information

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations SBCA Industry Standards Subcommittee Document: SBCA Series 6 Recommended Practices Date of Issue: Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

More information

Short-Circuit Current Calculations

Short-Circuit Current Calculations Basic Point-to-Point Calculation Procedure Step. Determine the transformer full load amps (F.L.A.) from either the nameplate, the following formulas or Table : Multiplier = 00 *% Z transformer Step 2.

More information

MILITARY SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/

MILITARY SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/ INCH-POUND MIL-DTL-17/152B 19 June 2015 SUPERSEDING MIL-C-17/152A 18 July 1985 MILITARY SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/152-00001 This specification is approved

More information

Technical and Economic Assessment of Upgrading a Double-circuit 63kV to a Single-circuit 230kV Transmission Line in Iran

Technical and Economic Assessment of Upgrading a Double-circuit 63kV to a Single-circuit 230kV Transmission Line in Iran Australian Journal of Basic and Applied Sciences, 5(1): 090-097, 011 ISSN 1991-8178 Technical and Economic Assessment of Upgrading a Double-circuit 63kV to a Single-circuit 30kV Transmission Line in Iran

More information

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2 Engineering Specification Electrical Networks MESP 130400-02 TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER Version: 1 Issued: November 2015 Owner: Engineering Division Approved By:

More information

STANDARD RTD's INDEX

STANDARD RTD's INDEX STANDARD RTD's INDEX PAGE General Information... R2 Temperature/Resistance Table... R6 Part Numbering Examples... R10 High Temperature MgO Elements (RA)... R11 Leadwire Style RTD's (RB)... R12 Leadwire

More information

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a. 734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was

More information

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2 Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/2.5 181mm 2 Version: 3 Issued: February 2017 Owner: Engineering Division Approved By: Andrew

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Item 550 Chain Link Fence

Item 550 Chain Link Fence Item Chain Link Fence 1. DESCRIPTION 2. MATERIALS Furnish, install, remove, repair, or replace chain link fence and gates. Furnish certification from the chain link fence materials manufacturer stating

More information

J-Poles. Mythbusting J-Pole Antennas

J-Poles. Mythbusting J-Pole Antennas Mythbusting J-Pole Antennas For an antenna to work correctly, it must do two things well 1) Accept power from the feed line impedance match, SWR (ideally) 1:1 2) Radiate power in a pattern that is useful

More information

,/;/ ...- H. ~.,,\"\ ~- ~ " "',. Nickel Alloy Ie Specialty Wire. OJ ~ / /., RE D. mog &CO~ 1-BOO-53-LOOS ~~.\. '.., '\" "" ..

,/;/ ...- H. ~.,,\\ ~- ~  ',. Nickel Alloy Ie Specialty Wire. OJ ~ / /., RE D. mog &CO~ 1-BOO-53-LOOS ~~.\. '.., '\  .. - w -. - a: -'~ - -.. ~,, I ''''. ~-- " ' ~ " "',. " ~~.\. '.., '\" "" H. ~.,,\"\ -\\ \; '. \\~~ ~ RE D...- I - ~- -- ---. "- I " '.1., / /.,.1 / )!)~ "'-:.. ~ -; -/' /. / i "/ i \ ~.. ~,/;/ / ~ Specialists

More information

Mongoose PT Platform Shale Shaker

Mongoose PT Platform Shale Shaker Mongoose PT Platform Shale Shaker (UL VERSION) Revision: A By: MT Mongoose Platform Page 1 of 10 NOTE: Mongoose PT Platform Shale Shaker The attached is a reference to M-I SWACO s STANDARD Mongoose Platform

More information

Kansas City Power & Light Company. Transmission Facility Rating Methodology

Kansas City Power & Light Company. Transmission Facility Rating Methodology Company Prepared by: KCP&L Transmission Planning December 6, 2017 Table of Contents 1. Purpose...4 2. Generator Rating Methodology...4 3....4 3.1. Equipment Rating Methodology...4 3.2. Items considered

More information

Telecommunication Wiring Questions

Telecommunication Wiring Questions Telecommunication Wiring Questions 1. is the process of modifying a carrier frequency in rhythm to the audio frequency. A, Modulation B. Amplitude C. Change of phase D. Interference 2. is the property

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 24 AWG stranded (7x32) TC conductor, Datalene insulation, pairs individually shielded with bonded Beldfoil with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil

More information

Roll No. :... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/ POWER SYSTEM-I. Time Allotted : 3 Hours Full Marks : 70

Roll No. :... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/ POWER SYSTEM-I. Time Allotted : 3 Hours Full Marks : 70 Name : Roll No. :.... Invigilator s Signature :.. CS/B.TECH(EE)/SEM-5/EE-502/2011-12 2011 POWER SYSTEM-I Time Allotted : 3 Hours Full Marks : 70 The figures in the margin indicate full marks. Candidates

More information

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C

More information

RP TNC Male Connector Crimp/Solder Attachment for PE-C240, RG8X, inch, LMR-240, LMR-240-DB, LMR-240-UF, B7808A

RP TNC Male Connector Crimp/Solder Attachment for PE-C240, RG8X, inch, LMR-240, LMR-240-DB, LMR-240-UF, B7808A RP TNC Male Connector Crimp/Solder Attachment for PE-C240, RG8X, 0240 inch, LMR-240, LMR-240-DB, LMR-240-UF, B7808A RF Connectors Technical Data Sheet PE44670 Configuration TNC Male Reverse Polarity Connector

More information

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line

More information

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs Republic Wire Inc. began operations in Cincinnati, Ohio in January of 1982. Ron Rosenbeck, owner and president of RWI, has been in the copper industry since 1973. Republic Wire orginally manufactured top-quality

More information

Transformer Factory Testing

Transformer Factory Testing Transformer Factory Testing John J. Foschia Test Engineer John.Foschia@spx.com September 2018 Reasons for Testing Compliance with user specifications Assessment of quality and reliability Verification

More information

Transmission Facilities Rating Methodology

Transmission Facilities Rating Methodology Document title Transmission Facilities Rating Methodology Document number EGR-TRMC-00009 Applies to: Transmission Engineering, Transmission System Operations, and Transmission Planning- Progress Energy

More information

EZ-WRAP Side Tie NOMENCLATURE GENERAL RECOMMENDATIONS (440) EN-CA

EZ-WRAP Side Tie NOMENCLATURE GENERAL RECOMMENDATIONS (440) EN-CA NOMENCLATURE IDENTIFICATION TAPE TIE TUBE INSULATOR IDENTIFICATION MARK C NECK BLACK F NECK YELLOW J NECK GREEN Conductor Tie Tube: For bare conductor, each tie is furnished with a Tie Tube Component.

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Coax (2-1505A Type) 20 AWG BC, GIFPE isulation, Duofoil plus TC braid (95% cv.), PVC inner jackets. Pairs (4-9451 Type): 22 AWG TC, PP insul.,

More information

IMPROVED PRODUCT. DSMZ (Z-Foil)

IMPROVED PRODUCT. DSMZ (Z-Foil) Ultra High Precision Bulk Metal Z-Foil Surface Mount Voltage Divider, TCR Tracking of < 0.1 ppm/ C, PCR of ± 5 ppm at Rated Power and Stability of ± 0.005 % (50 ppm) INTRODUCTION Bulk Metal Z-Foil technology

More information

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev. Page 1 of 5 Scope: The scope of this procedure is to describe how to properly install a cable pulling grip on an Optical Cable Corporation interlocked armor (ILA) and corrugated steel tape (CST) fiber

More information

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES THE SAFE APPLICATIO OF CABLES The cables manufactured by S are only appropriate for the transmission of electric energy for supply and signalling purposes. First of all the valid construction and installation

More information

AVA5-50FX. Product Classification. Standards And Qualifications. Construction Materials. Dimensions. Electrical Specifications

AVA5-50FX. Product Classification. Standards And Qualifications. Construction Materials. Dimensions. Electrical Specifications AVA5RK-50FX, HELIAX Andrew Virtual Air Coaxial Cable, corrugated copper, 7/8 in, black, Non-halogenated, fire retardant polyolefin jacket B2ca-s1b,d1 Product Classification Brand Product Series Product

More information

Fatima Michael college of Engineering and Technology

Fatima Michael college of Engineering and Technology Fatima Michael college of Engineering and Technology DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2303 TRANSMISSION AND DISTRIBUTION SEM: V Question bank UNIT I INTRODUCTION 1. What is the electric

More information

Maximum Recommended Load (lbs.) Grounding Procedure. Short Regular Duty ALUMA-FORM Platforms (3 5-1/8 wide) PLATFORMS

Maximum Recommended Load (lbs.) Grounding Procedure. Short Regular Duty ALUMA-FORM Platforms (3 5-1/8 wide) PLATFORMS PLATFORMS Your best solution for supporting transformers, regulators and other heavy equipment! Aluma-Form established the platform performance standards for the industry! They are superior in every category,

More information

Armoured Power and Control Cables to BS6883

Armoured Power and Control Cables to BS6883 Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in

More information

Thick Film Chip Resistors

Thick Film Chip Resistors Thick Film Chip Resisrs MCR Series < Not for Aumotive application > Features 1) Full line up from ultra small size (15) 2512 with jumper type. 2) ROHM resisrs have obtained ISO91/ISO/TS16949 certification.

More information

A short, off-center fed dipole for 40 m and 20 m by Daniel Marks, KW4TI

A short, off-center fed dipole for 40 m and 20 m by Daniel Marks, KW4TI A short, off-center fed dipole for 40 m and 20 m by Daniel Marks, KW4TI Version 2017-Nov-7 Abstract: This antenna is a 20 to 25 foot long (6.0 m to 7.6 m) off-center fed dipole antenna for the 20 m and

More information

IEC Standard Caledonian Offshore & Marine Cables

IEC Standard Caledonian Offshore & Marine Cables Power Copper s According to IEC 60228 Tinned conductors Cross section cl.2 cl.5 Cross section cl.2 cl.5 mm² Ohm/km Ohm/km mm² Ohm/km Ohm/km 1.0 18.2 20 70 0.270 0.277 1.5 12.2 13.7 95 0.195 0.210 2.5 7.56

More information

Appendix I. Applicant s Audible Noise and EMF Calculations

Appendix I. Applicant s Audible Noise and EMF Calculations Appendix I Applicant s Audible Noise and EMF Calculations Structure Type Predicted Intensity of Electric Fields (kv/m) at Maximum Operating Voltage Where Not Paralleling Existing Transmission Lines Line

More information

Times Microwave Systems Hermetically Sealed Assemblies

Times Microwave Systems Hermetically Sealed Assemblies SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 480.48 Diameter Hermetically Sealed Coaxial Transmission Lines. This product

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

1/2", Corrugated, Jacketed UL-910, CATVP AP012J Physical Dimensions Center Conductor

1/2, Corrugated, Jacketed UL-910, CATVP AP012J Physical Dimensions Center Conductor AirCell PLENUM CABLES 50 Ohm Plenum, 1/2" Description Product Number Frequency MHz Attenuation and Coupling Loss 1/2", Corrugated, Jacketed UL-910, CATVP AP012J50 5 0.159 0.56 17.6 10 0.225 0.82 12.0 20

More information