MTL7000 SERIES. Exceptionally high packing densities only 7mm barrier width

Size: px
Start display at page:

Download "MTL7000 SERIES. Exceptionally high packing densities only 7mm barrier width"

Transcription

1 MTL7000 SERIES ultra-slim safety barriers that can be used like terminals Exceptionally high packing densities only 7mm barrier width V dc supply connections simplified optional power comb feeds many barriers Direct connection of cable screens and lines third terminal on both hazardous and safe sides Patent US 887 MTL7000 Series award-winning, intrinsic safety shunt-diode safety barriers are innovative devices designed to provide exceptionally high packing densities, straightforward single-operation installation and simplified connection, commissioning and maintenance facilities. Many of the MTL7000 Series features duplicate the functions of conventional field terminals and the barriers can, therefore, double up as terminals for many applications, saving even more space. A barrier width of only 7mm enables maximum packing densities due to the use of surface mount and thick-film hybrid circuit technologies (subjects of patent applications). Barrier identification is provided by one or both of two methods. The first consists of tagging strips mounted on posts located at each end of a row of barriers while the other consists of separate identifiers attached to the tops of individual barriers. Of these, the first can be used to tag locations as well as barriers and is recommended for large installations while the second is better suited to installations of a few barriers only. An optional power comb simplifies installations where multiple barriers are powered from a common V dc source (via a power feed module or a dummy barrier). The comb replaces individual power supply connections to each barrier, yet allows single barriers to be removed without affecting the others. The power feed module powers up to 0 barriers and incorporates a trip which switches off the supply to the barriers if a fault (such as an overvoltage) occurs in the power source circuit. Secondary replaceable fuse versions of many barriers are available and form the MTL700 sub-series. These are useful where there is a possibility of faults occurring during commissioning which would otherwise blow the barriers' internal safety fuses. One secondary replaceable fuse for each barrier channel is provided and is lower in value than the related safety fuse. Fuses are packaged in small mouldings which can be latched in a 'disconnect' position to break the safe and hazardous s during commissioning, maintenance or fault finding, thus avoiding the need for additional disconnect terminals. Where a fuse is less likely to be necessary, the MTL700 sub-series uses a latchingout link only, to provide the basic loop disconnection of the MTL700 sub-series. EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

2 MTL7000 SERIES SPECIFICATIONS Key barriers shown in blue Model Safety Application Basic circuit Max. end- Vwkg at Vmax Internal safety No. description to-end 0µA fuse/fuse- MTL resistance disconnect(fd) (V) (Ω) (ma) (Ω) (V) (V) (ma) SINGLE CHANNEL +VE V dc systems (FD) } Controller outputs, (FD) solenoids 78P (FD) 79P+ 8 7 Controller outputs,.0. 0 (FD) solenoids (IIB) SINGLE CHANNEL VE For negative/ floating power supplies (FD) DOUBLE CHANNEL +VE V dc systems (FD) (FD) 7+ k Low-level/logic (FD) k return signals (FD) V dc systems (FD) 0 (FD) DOUBLE CHANNEL (NON-SYMMETRICAL) VE } Vibration probes (FD) (FD) RETURN-DIODE TYPE } Transmitters, diode controller outputs, + 0.9V switches (FD) 8 diode } + 0.9V (FD) 7087P Transmitters, 8 diode V controller outputs, 787P (FD) switches 8 diode + 0.9V (FD) SIMPLE AC, LOW LEVEL 70ac or -wire (floating) 0. at µa RTDs 0. at µa ac wire (grounded) 0. at µa RTDs 0. at µa at µa. 00 SIMPLE AC, HIGHER VOLTAGE 7ac Strain-gauge bridges wire RTD's } 70Pac Strain-gauge Pac 9 0 bridge, sense, output (FD) (FD) 7ac k Strain-gauge k bridge sense Pac 7 0 } Strain-gauge Pac 7 0 bridge supply (FD) (FD) EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

3 SPECIFICATIONS (continued) Model Safety Application Basic circuit Max. end- Vwkg at Vmax Internal safety No. description to-end 0µA fuse /fuse- MTL resistance disconnect (FD) (V) (Ω) (ma) (Ω) (V) (V) (ma) STAR-CONNECTED AC 700ac Active dc and ac sensors, ac thermocouples (FD) (FD) } } 7ac wire dc/ac ac systems ACTIVE BARRIERS Transmitters Transmitters Switches 8 +.V 0 8 diode + 0.9V Solenoids, alarms, 8 +.V 0 LEDs DUMMY BARRIERS 7099 Securing and earthing unused cables and screens. 799 Feed-through connections for power comb. All barriers have internal, inaccessible, safety fuses. MTL700 barriers have additional replaceable fuses, lower in value than the internal fuses. It is the value of the replaceable fuse that is quoted for MTL700 barriers. Note : Ω ±0.Ω at 0 C, channels track within 0.Ω from 0 to +0 C. Note : In star-connected barriers (eg, MTL700/70), the two channels are interlocked such that the voltage between them cannot exceed the working voltage, V wkg. Note : MTL778ac: the working voltage between the two interlocked channels is.; V max is.v. CERTIFICATION MTL7000 Series barriers protect devices located in all normally occurring explosive atmospheres, including air/flammable gasmixtures, dusts and fibres. MTL7000 Series barriers are certified [EEx ia] IIC (except MTL79P+, certified IIB) BY BASEEFA to CENELEC standards, by FM in the USA, CSA in Canada and also by other authorities, providing worldwide certification. MTL7000 Series barriers are designed to the same safety descriptions as MTL700 Series equivalents (in some cases slightly stricter) and can therefore be used for the same applications. HOW THEY WORK All MTL7000 Series barriers are based on the same simple principle. Each channel contains three stages of Zener or forward-connected diodes and an infallible terminating resistor. In the event of an electrical fault in the safe, the diodes limit the voltage that can reach the hazardous and the resistor limits the current: active output-current limiting circuits are not used. An internal fuse protects the diodes, and the three stages of voltage limitation ensure continued safety if the first or second stage should fail. MTL700 barriers have an additional replaceable fuse which protects the internal fuse. The MTL7000 Series includes seven key barrier types which cover the majority of applications, simplifying barrier selection and the maintenance of spares stocks. SUB-SERIES MTL7000 Series barrier circuits are based on the well-proven designs originally developed for the MTL700 Series. To simplify identification for those familiar with the latter, part numbers are the same for equivalent barriers, but with a 0, or inserted after the initial 7 to identify the relevant sub-series: Note : Limited availability. Use MTL770+ as an alternative. P suffix Barriers with a P suffix are higher-power versions of the standard devices with lower end-to-end resistance, except the MTL70Pac/7Pac. They are suitable for type IIC gas groups, except MTL79P+ which is designed for IIB. WARNING Check compatibility of the electrical safety parameters of the field equipment with those of the barriers to make sure that the combination is safe. MTL7000 MTL700 MTL700 standard fuse-disconnect link-disconnect Note: the circuit shown is as an example only. Standard, fuse- or link-disconnect options are shown shaded in the 'basic circuits' in the specifications tables. KEY BARRIERS SUMMARISED TYPE APPLICATION KEY BARRIER Analogue Resistance temperature detectors 70ac 700ac input (low level) Thermocouples, ac sensors 70ac Analogue Controller outputs, one line earthed output Controller outputs, neither line earthed dc power supply. 0-V Analogue Transmitters, -wire, /0mA input (high level) 787+ Digital (on/off) Switches input 787+ Digital (on/off) Solenoids, alarms, LEDs output 78+ EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

4 ACTIVE BARRIERS MTL70/MTL70, MTL707+ and 708+ active barriers The MTL70/MTL70, MTL707+ and 708+ barriers have built-in overvolt protection, allowing their use with unregulated power supplies. In many applications, eg, sensor inputs or controller outputs, there is insufficient power available to blow the barrier fuse and this additional protection is not necessary. But, where the barrier is connected to a power supply, eg, for energising transmitters, switches, solenoids or local alarms, overvolt protection allows the barriers to be used with unregulated supplies up to V dc and also gives protection against faulty wiring during commissioning. The MTL70, 707+, 708+ are equipped with a loop disconnect at power supply terminal while the MTL70 has a fuse-disconnect. Nearest equivalent passive barriers MTL70 nearest equivalent MTL78 /787+ MTL70 nearest equivalent MTL708 /7087+ MTL707+ nearest equivalent /787+ MTL708+ nearest equivalent MTL708+/78+ MTL70/70 for -wire /0mA and smart transmitters 00mA MTL70 Fuse disconnect The MTL70/MTL70 is a single-channel barrier designed primarily for energising a conventional or 'smart' -wire /0mA hazardous- transmitter. They can be thought of as an MTL78 or an MTL708 barrier with a built-in floating power supply and electronic over-volt protection. It provides a high voltage output (which is negative with respect to earth) to power the transmitter and delivers a /0mA signal into an earthed load in the safe-. The novel design is noted for its extreme accuracy. + /0mA 0mA /0mA MTL70 Loop disconnect link +0 to V Load resistor SPECIFICATION Supply voltage 0 to V dc Supply current 0mA typical at 0mA with 8V dc supply ma typical at 0mA with V dc supply 0mA maximum at 0mA with dc supply Voltage for transmitter and lines. minimum at 0mA with 0Ω load.v minimum at 0mA with 00Ω load Note that the output voltage is negative with respect to earth. Safe- load resistance 0 to 00Ω Output current 0 to.ma Accuracy ±µa ( to 0mA) Out of range capability Over-range; >0mA to.ma Under-range; <ma to 0mA Smart compatibility HART Communication Foundation HART Honeywell DE Yokogawa BRAIN Foxboro smart Fuji smart Chessel 00 Series Patent Nos UK: 099 European (Germany, France, Italy): EP BI USA: 970 HART is a registered trademark of HART Communication Foundation EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

5 MTL707+ for digital (switch) inputs Loop disconnect link Current limit SPECIFICATION Supply voltage, terminal +0 to +V dc Normal operation In normal operation the protection circuit introduces only a small voltage drop and shunts less than.ma to earth, so its overall effect is minimal Supply voltage >7V If the supply voltage exceeds about 7V, causing the Zener diodes to conduct, or if the safe- load has a very low resistance, the supply current is limited automatically to <0mA. This protects the fuse and power supply and enables the loop to continue working. Supply current At Vs <V; Iout +.ma max At Vs >8V or low load resistance; limited to <0mA Internal fuse, terminal 0mA Reverse voltage protection, terminal Yes 0mA + I out.ma max 0 to V dc max 0mA Maximum voltage drop, terminals to [(Iout x 8Ω) +.]V (current not limited) Output current (Iout), terminal Up to ma Leakage to earth.ma max Internal fuse, terminal 0mA Maximum voltage drop, terminals to [(I out x Ω) + 0.9]V MTL708+ for digital (switched) outputs Loop disconnect link Current limit SPECIFICATION Supply voltage, terminal +0 to +V dc Normal operation In normal operation the protection circuit introduces only a small voltage drop and shunts less than.ma to earth, so its overall effect is minimal Supply voltage >7V If the supply voltage exceeds about 7V, causing the Zener diodes to conduct, or if the safe- load has a very low resistance, the supply current is limited automatically to <0mA. This protects the fuse and power supply and enables the loop to continue working. Supply current At Vs <V; Iout +.ma max At Vs >8V or low load resistance; limited to <0mA Internal fuse, terminal 0mA Reverse voltage protection, terminal Yes Maximum voltage drop, terminals to [(Iout x 0Ω) +.]V (current not limited) Output current (Iout), terminal Up to ma Leakage to earth.ma max LED, alarm, solenoid, etc 0mA + I out.ma max 0 to V dc max EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

6 MTL799 power feed module Green power LED Solid-state switch Current sense Voltage sense Trip circuit 800mA max Red fault LED To barriers via power comb External power supply 0 to.8v dc at.8a min The MTL799 power feed module incorporates both voltage and current sense mechanisms to protect barrier circuits by activating a solid-state trip mechanism when fault or overload conditions occur in the power source circuit. Resetting the module after tripping is done by interrupting the supply to the unit. A red LED indicates a circuit trip condition and a green LED the availability of power at the outputs. SPECIFICATION Input voltage range (terminals and ) 0 to.8v Maximum input voltage capability V Power source requirement Power source must be capable of delivering at least.8a Trip mechanism Minimum trip operating voltage:.8v (at 0 C ambient) at output terminal wrt earth Temperature coefficient: +8.mV/ C MTL799 Output current range (terminal wrt earth) 0 to 800mA LED indication Green: indicates power at output terminals (ie, power being fed to barriers) Red: indicates trip condition (ie, overvoltage or overcurrent state) Maximum voltage drop 0mV at 0mA load, 0 to +0 C. at 800mA load, 0 to +0 C Maximum number of barriers powered Load dependent, eg: 0 x * at 0mA (/0mA loops) * Or fuse-disconnect or P versions GENERAL SPECIFICATION Ambient temperature limits 0 to +0 C (FM/CSA) continuous working 0 to +0 C (BASEEFA) continuous working 0 to +80 C storage Humidity limits to 9% RH Case flammability UL9: V- Terminations Terminals accommodate conductors up to.mm - terminals are identified as dark blue Colour coding of barrier type (label on top surface) Red: Positive polarity (+) Black: Negative polarity ( ) Black (with red text): MTL70/70 Grey: Non-polarised (ac) White: MTL7099/799 dummy barrier Orange: MTL799 power feed module Weight 00g approximately Mounting and earthing Clamping onto standard mm 'top-hat' DIN-rail: 7.mm (low profile) or mm (high profile) DIMENSIONS (mm) 0. terminals MTL7XXX Fuse/link positions (MTL700/700) Safe- terminals 0. (7.mm rail) 09. (mm rail) 99 Installation and approval side label Note: All specifications quoted at 0 C ambient unless otherwise stated. Colour-coded top label Channel (terminal to ) Channel (terminal to ) MTL7XXX EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

7 MTL7000 SERIES BARRIER APPLICATIONS ANALOGUE INPUTS (HIGH-LEVEL) -wire transmitters, /0mA, conventional and smart Recommended barriers for use with 'conventional' and 'smart' /0mA transmitters (fed by a regulated supply) are the /787+ or /787P+. These provide up to.v at V wkg and 0mA for a transmitter and its lines as well as V for the typical 0Ω load. This application and these barriers are suitable for use with the optional power comb. The MTL70/70 is recommended for applications where an unregulated supply of up to V is used. It provides. for transmitter and lines at 0mA as well as V for a typical 0Ω load. With the MTL70/70 terminal is negative with respect to earth, so the connections to terminals and should be reversed. MTL7000 Series barriers protect devices located in all normally occurring explosive atmospheres, including air/flammable gas mixtures, dusts and fibres. Applications covered include the protection of installations incorporating uncertified devices ( simple apparatus ) such as thermocouples, switches and resistive sensors, or separately certified energy storing (or voltage producing ) apparatus including ac sensors, transmitters and current-to-pneumatic (I/P) converters. Recommended choices for specific applications are discussed briefly in the following pages. These are examples, and many other configurations will suggest themselves. For advice on a particular application, please contact MTL. MTL787+ MTL787P+ MTL70 MTL70 /0mA +V V 0Ω Vibration probes The -wire transmitters used with vibration monitoring equipment are invariably supplied by a V dc power supply hence the recommended barrier choice is the negatively-polarised MTL709 /79. The third terminal makes this choice ideal for these -wire applications. Probe driver Transducer MTL709 MTL79 Monitor V V out ANALOGUE INPUTS (LOW-LEVEL) Thermocouples and mv sources The recommended barrier for thermocouples and mv sources is the MTL700ac/70ac. This -channel non-polarised barrier retains the earth-free nature of the signal and, providing the receiver s input floats, rejects common-mode ac and dc interference up to at least 7V and is unaffected by earth faults on the primary element. Compensating cable MTL700ac MTL70ac Recorder Controller Data logger Computer ac sensors, photocells, microphones and turbine flowmeters The MTL700ac/70ac is the recommended choice for these devices. While many of these are designated simple apparatus and thus do not need certification, note that some ac sensors may be subject to a significant level of inductance and will therefore need to be designed and certified for hazardous- locations. Photocell Microphone Turbine flowmeter MTL700ac MTL70ac Earth free signal Slidewire displacement transducers The simplest choice is the MTL700ac/70ac. This barrier supplies power and brings back a unipolar signal. MTL700ac MTL70ac +7.V V out EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

8 RTDs For -wire RTDs, a single MTL70ac barrier is the most economical choice. This is suitable for use with a floating bridge the two leads from the bridge arms are protected by the barrier with the third (supply) lead being earthed through the barrier. The barrier has a low end-to-end resistance of only Ω/channel to minimise span changes and its channels track within 0.Ω (between 0 to +0 C) to minimise zero shift with temperature. MTL70ac Receiver If the bridge circuit is already earthed, the third barrier channel provided by an MTL70ac is needed. For extreme accuracy, channels and an earth-free bridge can be used, a configuration that cancels out the small errors due to barrier leakage. Channels and (those between terminals &, and & respectively) track to within 0.Ω between 0 and 0 C. MTL70ac Receiver -wire constant-current circuits do not need matched barrier resistances and can be protected by two MTL7ac barriers. If the increase in loop resistance is too great, use two MTL70ac barriers instead. MTL7ac MTL70ac Receiver MTL7ac MTL70ac STRAIN-GAUGE BRIDGES Single strain-gauge bridges This shows an arrangement using two or three barriers, which is safe in IIC gases. With the MTL7ac, the circuit is powered from a V, 0Ω source; if the bridge resistance is 0Ω, then the bridge voltage is 7V. If the bridge resistance is 0Ω, then the bridge voltage is 8.V. +7V 7V An MTL7ac can be used to sense the bridge supply voltage. MTL7ac An MTL7ac is used here for the mv output. An MTL7Pac provides.v for a 0Ω bridge with a supply. MTL7Pac's can be used for the sense and pick-off circuits. + Sense MTL7ac Output (mv) MTL7ac EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

9 Double strain-gauge bridges Quite frequently there is a demand to monitor two load cells, and a possible circuit, safe in IIC, is shown. Here, the lower voltage drop of the MTL70Pac is an advantage. The MTL70Pac supplies power to the bridge(s) whilst two MTL70Pac/7Pac barriers interface with the sense and pick-off circuits. MTL70Pac + Using 0Ω bridge systems, the following voltages are available from an MTL70Pac with a ± supply: bridge:.8v bridges: 9.V MTL70Pac MTL7Pac + Sense Output (mv) MTL70Pac MTL7Pac ANALOGUE OUTPUTS Controller outputs (I/P converters) The single-channel MTL708+/78+ with a voltage drop of.7v/.9v is the recommended choice for most controller outputs. Higher-power versions are available: the MTL78P+ (.V drop) is suitable for IIC applications; the MTL79P+ (.V drop) for IIB applications. P I MTL708+ MTL78+ MTL78P+ *MTL79P+ +V For controllers with an output circuit separated from the rail by the control transistor, the -channel /787+ is the preferred choice as the return channel can handle up to./. allowing the control signal to be turned off completely. The voltage drop is 8.V/8.V at 0mA. A higher-power version of the latter, the /787P+, is also available. The return channel of these barriers handle up to./. and the maximum voltage drop is only.7v/7.v. The /787+ and /787P+ are also suitable for controllers containing a resistor which enables the return current to be monitored for high-integrity operation. P I P I MTL787+ MTL787P+ MTL787+ MTL787P+ * CENELEC gas group IIB (C & D N. America) +V +V Monitor rail EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

10 DIGITAL (ON/OFF) INPUTS Switches The normal choice is the /787+ with a regulated supply. The MTL707+ is recommended for applications where an unregulated supply of up to V is used. For optimum power transfer, with relays the resistance of the load should be approximately equal to the combined resistance of the two channels and the relay coil should then be rated at about half the supply voltage. MTL787+ MTL707+ +V Logic signal DIGITAL (ON/OFF) OUTPUTS Alarms, LEDs, solenoids valves, etc For these applications, the MTL708+/78+ is recommended. Higher-powered versions are available: the MTL78P+ is suitable for IIC applications; the MTL79P+ for IIB applications. The MTL708+ is recommended for applications where an unregulated supply of up to V is used. If the control switch is to earth, then the -channel /787+ barrier should be used, or, alternatively, the /787P+ higher-power version. If the supply is poorly regulated use the MTL707+. LED, alarm LED, alarm MTL708+ MTL78+ MTL78P+ *MTL79P+ MTL708+ +V *CENELEC gas group IIB (C & D N. America) +V MTL787+ MTL787P+ MTL707+ +VE DC SYSTEMS Low-level to V dc systems The two channels of the MTL7+, MTL7+ and MTL77+ can be combined safely in IIC. The MTL7+ can be used for low-level logic return signals. The MTL7+ and MTL77+ are used for V dc and V dc systems respectively. dc systems MTL7+ MTL7+ MTL77+ +V/9V/V +V/9V/V 8V dc systems The single-channel MTL7+ is recommended for 8V dc systems. dc systems +8V MTL7+ AC AND DC SYSTEMS High-level ac and dc systems The versatile star-connected MTL7ac and MTL778ac allow V wkg to be developed from each channel to ground but only allow V wkg to be developed between channels. This provides some common-mode voltage capability and can allow higher cable parameters to be used. dc and ac systems MTL7ac MTL778ac V/V NEGATIVE AND FLOATING POWER SUPPLIES Digital (on/off) outputs The MTL708 /78 is used with a negative power supply and positive earth. Typically used for digital inputs or outputs, as shown. The MTL708-/78- can also be used with floating power supplies, for transmitters. LED, alarm MTL708 MTL78 + V EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

11 POWER COMB APPLICATIONS The PWC7000 power comb is invaluable for saving installation time and wiring when connecting a V dc power source to a number of barriers. Typical applications include hazardous- switches, /0mA transmitters and solenoids. The diagram illustrates the configuration for barriers but up to 0 barriers can be served by this method. MTL799 OR MTL7099 MTL799 External V dc supply The MTL799 power feed module would normally be used with standard barriers such as and because the current/voltage trip protection mechanism of the MTL799 removes the need for replaceable fuses in the barriers. The MTL7099/799 dummy barriers can be used instead of the MTL799 for direct feed-through connection of a V dc supply. In these circumstances, replaceable fuse barriers such as MTL787+ and MTL787P+ may be preferred. MTL787+ MTL787P+ Logic signal The MTL799 dummy barrier has a removable link between terminals and for easy disconnection of the supply. Other units which can use the power comb: MTL70 MTL70 MTL707+ MTL708+ MTL787+ MTL787P+ Logic signal MTL787+ MTL787P+ Logic signal Power comb PWC7000 SPARE CABLE CORES AND SCREENS The MTL7099/799 dummy barriers are used primarily for securing and earthing unused cables and screen connections. terminals, and (and safe terminal ) are internally connected to the DIN-rail mounting/earth connection. Unused cable cores and screens MTL7099 MTL799 WIRED IN APPLICATIONS MTL799s can be 'looped-in' to provide link-disconnects for MTL70xx barriers, eg. as shown here with an MTL70ac and an RTD. For high accuracy or sensitive low level applications check that the additional connections do not degrade the signals. MTL70ac MTL799 Receiver MTL799 EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

12 MAXIMUM CABLE PARAMETERS Model no. Number of single Maximum permissible cable parameters channels interconnected Earth BASEEFA (group IIC (hydrogen)) FM (Groups A & B) Matched within return Capacitance Inductance L/R ratio Capacitance Inductance power hazardous used? (µf) (mh) (µh/ω) (µf) (mh) (W) MTL70/70 Yes MTL707+ Yes MTL708+ Yes MTL7+ Yes MTL708+/78+ Yes MTL78P+ Yes MTL708 /78 Yes MTL79P+ Yes IIB (C&D) only MTL70ac Yes Yes No No Yes MTL70ac Yes No MTL700ac/70ac Yes Yes MTL70Pac/7Pac No MTL7ac Yes Yes MTL7+ Yes Yes No MTL7+ Yes Yes MTL7ac Yes Yes No MTL7ac Yes Yes MTL70Pac/7Pac Yes MTL77+ Yes Yes MTL778ac Yes Yes /787+ Yes /787P+ Yes MTL709 /79 Yes Notes Key barriers in bold If values are not quoted for when on earth return is not used, then those for an earth return ('Yes' in the tables) are applicable For most practical purposes, the values of the parameters for groups IIB and IIA are respectively and 8 times the values for group IIC The maximum power that can be drawn from the barrier or barrier combination under fault conditions; used for assessing the temperature classification of simple' hazardous- apparatus TERMINOLOGY Safety description The description of a barrier, eg, 0ž 00mA, refers to the maximum voltage of the terminating Zener or forward diode when an internal safety fuse is blowing, the minimum value of the terminating resistor, and the corresponding maximum short-circuit current. It is an indication of the fault energy that can be developed in the hazardous and not of the working voltage or end-to-end resistance. Polarity Barriers may be polarised positive ( + ) or negative ( ) or nonpolarised ( ac ). Polarised barriers accept and/or deliver safe- voltages of the specified polarity only. Non-polarised barriers support voltages of either polarity applied at either end. The exception is the MTL70 which takes a positive supply but provides an output voltage which is negative with respect to earth. End-to-end resistance The resistance between the two ends of a barrier channel at 0 C, ie, of the resistor and the fuse(s). If diodes or transistors are present, the voltage drop of these is also quoted. Working voltage (Vwkg) The greatest steady voltage, of appropriate polarity, that can be applied between the safe- terminal of a basic barrier channel and earth at 0 C for the specified leakage current, with the hazardous- terminal open circuit. Maximum voltage (Vmax) The greatest steady voltage, of appropriate polarity, that can be applied continuously between the safe- terminal of any barrier channel and earth at 0 C without blowing the internal safety fuse/external replaceable fuse (MTL700). For basic barriers it is specified with the hazardous- terminal open circuit; if current is drawn in the hazardous, the maximum voltage for these barriers is reduced. The ac channels of basic barriers withstand voltages of the opposite polarity also see the circuit diagrams included under Applications. Fuse ratings The greatest current that can be passed continuously through the fuse for 000 hours at C. Maximum safe- voltage (U m ) The maximum permissible safe- voltage (U m ) for MTL7000 Series barriers is ac/dc. EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

13 HOW TO ORDER MTL7000/700/700 barriers Select by barrier number and polarity, e.g. MTL708+ Mounting accessories THR Standard DIN-rail, x 7.mm THR7000 T-section DIN-rail, specially-plated, x 7.mm, m length ISP7000 Insulating spacer Standard earthing/earth-rail accessories ETL7000 Earth terminal, DIN-rail mounted IMB7 Insulating mounting block ERB7S Earth-rail bracket, straight ERB7O Earth-rail bracket, offset ERL7 Earth rail, m length ETM7 Earth terminal, pack of 0 Replaceable fuses/removable links RFA700 Replaceable fuse assemblies, 0mA, pack of RFA700 Replaceable fuse assemblies, 00mA, pack of RLA7000 Removable link, pack of Enclosures DX070 Enclosure, for MTL7000 x 9 DX70 Enclosure, for MTL7000 x DX0 Enclosure, for MTL7000 x 8 Literature INM7000 Instruction manual, MTL7000 Series INM7ENC Instruction manual, MTL000/7000 Series Enclosures CD Customer drawings Standard tagging accessories TAG7 Tagging strip, m length TGL7 Tagging strip labels, set of 0 x 0.m BRI7000 Barrier identifier BIL7000 Barrier identification labels, sheet of 0 BIL7000L Barrier identification labels, A sheet of CORRELATION BETWEEN MTL7700 MTL7000 MTL700 BARRIERS (IIC) Module No. Bussed MTL7000 MTL7000 MTL7000 MTL700 MTL700 MTL700 Typical Power? Equivalent Original ATEX equivalent Original ATEX Application Certificate Certificate Certificate Certificate Number(s) Number(s) Number(s) Number(s) MTL770+/- No Half of Ex9C BAS99ATEX78 MTL70+/- Ex8 BAS0ATEX70 /V MTL7+/- Systems MTL77+/- No N/A N/A N/A MTL7+/- Ex8 BAS0ATEX70 V Systems MTL77P+/- No N/A N/A N/A MTL7P+ Ex9C7 BAS0ATEX70 V Systems MTL77+/- No MTL7+/- Ex9C BAS99ATEX78 MTL7+/- Ex8 BAS0ATEX70 General Purpose MTL778+/- No MTL708+/- Ex9C BAS99ATEX78 MTL78+/- Ex8 BAS0ATEX70 Analogue / Digital MTL78+/- MTL778ac No N/A N/A N/A MTL78ac Ex8 BAS0ATEX70 General Purpose MTL778P+/- No MTL78P+/- Ex9C BAS99ATEX78 MTL78P+ Ex9C7 BAS0ATEX70 Analogue / Digital MTL77ac No MTL70ac Ex9C BAS99ATEX78 MTL7ac Ex8 BAS0ATEX70 RTD, Grounded MTL77ac No MTL70ac Ex9C BAS99ATEX78 N/A N/A N/A RTD, Grounded MTL770ac No N/A N/A N/A MTL70ac Ex8 BAS0ATEX70 Active sensors, Thermocouples MTL77ac No MTL7ac Ex9C BAS99ATEX78 MTL7ac Ex8 BAS0ATEX70 Strain Gauges MTL77Pac No MTL70Pac Ex9C BAS99ATEX78 MTL7Pac Ex9C7 BAS0ATEX70 Load cell MTL7Pac MTL77+/- No MTL7+/- Ex9C BAS99ATEX78 MTL7+/- Ex8 BAS0ATEX70 High resistance MTL77ac No MTL7ac Ex9C BAS99ATEX78 MTL7ac Ex8 BAS0ATEX70 Strain / Level Gauges MTL77ac No N/A N/A N/A MTL7ac Ex8 BAS0ATEX70 General Purpose MTL77ac No N/A N/A N/A MTL7ac Ex8 BAS0ATEX70 Strain Gauges MTL77Pac No MTL70Pac Ex9C BAS99ATEX78 MTL7Pac Ex9C7 BAS0ATEX70 Strain Gauges MTL7Pac MTL777+/- No MTL77+/- Ex9C BAS99ATEX78 MTL77+/- Ex8 BAS0ATEX70 Dual MTL7 MTL7779+/- No N/A N/A N/A MTL779+/- Ex8 BAS0ATEX70 Dual MTL78 MTL7787+/- Yes /- Ex9C BAS99ATEX78 MTL787S+ Ex8 BAS0ATEX70 Analogue / Digital MTL787+/- MTL7787P+/- Yes Ex9C BAS99ATEX78 MTL787SP+ Ex9C7 BAS0ATEX70 Analogue / Digital MTL787P+ MTL7788+/- Yes N/A N/A N/A MTL788+/- Ex8 BAS0ATEX70 Transmitters MTL7788R+/- Yes N/A N/A N/A MTL788R+/- Ex8 BAS0ATEX70 V systems MTL779+/- No MTL709+ Ex9C BAS99ATEX78 MTL79+/- Ex8 BAS0ATEX70 Gas Metering MTL79- EUROPE (EMEA) Tel: + (0)8 7 Fax: + (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: June 00

MTL7700 SERIES BARRIER APPLICATIONS

MTL7700 SERIES BARRIER APPLICATIONS MTL00 SERIES BARRIER APPLICATIONS MTL00 Series barriers protect devices located in all normally occurring explosive atmospheres, including air/flammable gas mixtures, dusts and fibres. Applications covered

More information

STRAIN-GAUGE BRIDGES. Safe Area. Hazardous Area. MTL7755ac. MTL7764ac. MTL7755ac MTL7761ac. MTL7755ac MTL7761ac

STRAIN-GAUGE BRIDGES. Safe Area. Hazardous Area. MTL7755ac. MTL7764ac. MTL7755ac MTL7761ac. MTL7755ac MTL7761ac MTL00 RANGE BARRIER APPLICATIONS MTL00 range barriers protect devices located in all normally occurring explosive atmospheres, including air/flammable gas mixtures, dusts and fibres. Applications covered

More information

MTL7700 SERIES Shunt-diode safety barriers

MTL7700 SERIES Shunt-diode safety barriers DIN rail mounting safety barriers MTL7700 SERIES Shunt-diode safety barriers Removable terminals feed to other modules Proximity detector inputs Relay and solid state switch modules Dual channel variants.mm

More information

technical datasheet technical datasheet MTL7700 Series DIN-rail mounting safety barriers

technical datasheet technical datasheet MTL7700 Series DIN-rail mounting safety barriers technical datasheet technical datasheet MTL7700 Series DIN-rail mounting safety barriers Removable terminals feed to other modules Relay and solid state switch modules Dual channel variants.mm per channel

More information

MTL7700 range DIN-rail mounting safety barriers

MTL7700 range DIN-rail mounting safety barriers Technical data MTL intrinsic safety solutions September 07 EPS7700 Rev MTL7700 range DIN-rail mounting safety barriers Removable terminals feed to other modules Relay and solid state switch modules Dual

More information

MTL700 SERIES. Shunt-diode safety barriers. For safe measurement and control in hazardous areas. 1 or 2 channels in same slim package

MTL700 SERIES. Shunt-diode safety barriers. For safe measurement and control in hazardous areas. 1 or 2 channels in same slim package For safe measurement and control in hazardous areas MTL700 SERIES Shunt-diode safety barriers or channels in same slim package Electronic protection prevents blown fuses Higher-power barriers for group

More information

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web: -

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web:  - MZB SERIES Intrinsically Safe Shunt Diode Safety Barriers Turck of Intrinsically Safe Shunt Diode Safety Barriers New series of Zener Barriers include a wider product range for more flexibility in more

More information

MTL4000 SERIES. isolating IS interface units. For close integration of IS circuits into processconnected

MTL4000 SERIES. isolating IS interface units. For close integration of IS circuits into processconnected For close integration of S circuits into processconnected systems 1 MTL4000 SERES isolating S interface units Compact modular design with plug-in connections High module/channel packing densities System

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

DRAFT 25 January Instruction manual MTL intrinsic safety solutions. January 2018 INM 7700 Rev 13. MTL7700 range. Shunt-diode safety barriers

DRAFT 25 January Instruction manual MTL intrinsic safety solutions. January 2018 INM 7700 Rev 13. MTL7700 range. Shunt-diode safety barriers DRAFT 5 January 08 Instruction manual MTL intrinsic safety solutions January 08 INM 7700 Rev MTL7700 range Shunt-diode safety barriers DRAFT 5 January 08 DECLARATION OF CONFORMITY A printed version of

More information

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

MTL700 and 700P Series shunt-diode safety barriers

MTL700 and 700P Series shunt-diode safety barriers MTL700 and 700P Series shunt-diode safety barriers Instruction Manual INM700 Contents Page 1 INTRODUCTION........................................................... 1 2 DESCRIPTION............................................................

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

The SENSE and SIGNAL inputs are very high impedance and are unaffected by the (~384ohm) series resistance of the xx61p barriers.

The SENSE and SIGNAL inputs are very high impedance and are unaffected by the (~384ohm) series resistance of the xx61p barriers. Hazardous Area Application Note CSW and CPI. Indicator IS Barrier Applications. Ian Fellows LIMITED Introduction When the weight indicator or digitiser is not Intrinsically Safe (all current Ian Fellows

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

INTRINSIC SAFETY BASIC PRINCIPLES

INTRINSIC SAFETY BASIC PRINCIPLES INTRINSIC SAFETY BASIC PRINCIPLES IGNITION TRIANGLE Ignition Energy In many industrial processes, the presence of flammable materials (gases, vapours, liquids, dusts, fibres and flyings) requires the adoption

More information

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transducer transmitter BILT 4 II 2(1) G. Technical Manual GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

2002 IS Catalog. Page

2002 IS Catalog. Page Page Introduction... 95 Current Repeaters/Drivers (Single-channel) KFD0-CS-Ex1.50P (Transmitter, positioner and indicator)... 96 KFD0-CS-Ex1.51P (Positioner and fire detector)... 97 KFD0-CS-Ex1.52 (Current

More information

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks Megablocks are DIN-rail mounted passive hubs for FOUNDATION fieldbus networks. They connect several field devices

More information

Certificate of Conformity

Certificate of Conformity Applicant: Trolex Limited Newby Road, Hazel Grove Stockport SK7 5DY UK Electrical Apparatus: Programmable Sensor Controller Type TX9042 Type of Protection: Ex ia Marking Code: Trolex Ltd TX9042 Programmable

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Safety Barriers 2/1. Hazardous area. 250 V max I.S.

Safety Barriers 2/1. Hazardous area. 250 V max I.S. /0 Safety barriers Exchangeable back-up fuse for all safety barriers Snap-on mounting on rails: simultaneous connection to potential equalisation/ ground Simple selection: application specific single and

More information

Zener barriers - operating instructions Application examples

Zener barriers - operating instructions Application examples Информационный лист DSe_IB_Zexamples Zener barriers - operating instructions. Temperature measurement Z0 Not grounded Temperature monitoring or control The simplest and most favourably priced solution

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

OPTITEMP TT 10 C/R Technical Datasheet

OPTITEMP TT 10 C/R Technical Datasheet OPTITEMP TT 10 C/R Technical Datasheet Analogue 2-wire temperature transmitter Temperature linear 4...20 ma output Rangeable with solder pads and potentiometers Easy wiring through large center hole The

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

Electronic Circuit Protector ESX10

Electronic Circuit Protector ESX10 Electronic Circuit Protector ESX0 Description Electronic circuit protector type ESX0 is designed to ensure selective disconnection of DC 24 V load systems. DC 24 V power supplies, which are widely used

More information

Interfaces Galvanic Isolators Trip Amplifiers Converters:

Interfaces Galvanic Isolators Trip Amplifiers Converters: Interfaces between field mounted devices in explosive hazardous areas and non hazardous areas are useful to prevent a transfer of ignition energy from the non hazardous area into the explosive hazardous

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Railbus isolator. Railbus isolator 8922-RB-IS

Railbus isolator. Railbus isolator 8922-RB-IS Railbus isolator Railbus isolator 8922-RB-IS provides galvanic isolation between Railbus sections prevents fault-voltage invasions protects IS field wiring modules See also System Specification Dimensions

More information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For water and wastewater Model LW-1 Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Electronic Circuit Protector ESX10-T

Electronic Circuit Protector ESX10-T Electronic Circuit Protector ESX0-T Description Electronic circuit protector type ESX0-T is designed to ensure selective disconnection of systems. power supplies, which are widely used in industry today,

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Title: INTRINSIC SAFETY MADE EASY

Title: INTRINSIC SAFETY MADE EASY Title: INTRINSIC SAFETY MADE EASY By: TH Kuan KL Automation Engineering Sdn. Bhd. ICA 2006 Date: 19.02.2006 Profile of Kuan Teik Hua Mr. Kuan is a Director for KL Automation Engineering Sdn Bhd. He has

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

F2xx & F2xx-XE megablock range

F2xx & F2xx-XE megablock range Technical data MTL fieldbus networks September 0 EPS Fxx rev Fxx & Fxx-XE megablock range Passive hubs for zone & division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation

More information

megablock series passive hubs for fieldbus networks

megablock series passive hubs for fieldbus networks passive hubs for fieldbus networks Relcom megablock series Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They connect several field devices to the network trunk cable and

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional

More information

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol SIL IEC 6 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol Data Sheet 0068_en_03 PHOENIX CONTACT 0-07-09 Description Temperature FL ϑ Universal PC programmable

More information

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50 Technical Information Nivotester 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50 Area of application The Nivotester is suitable as a 1-channel switch amplifier for the Soliwave

More information

TI25 - Pre-Instructional Survey

TI25 - Pre-Instructional Survey TI25 - Pre-Instructional Survey Name: Date: 1. Scheduled maintenance that is planned, with materials on hand, personnel on site, and production planning advised is called maintenance. a. predictive b.

More information

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3. TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement

More information

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT - 09/2009 Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

Level Measurement silometer FMX 570

Level Measurement silometer FMX 570 Technical Information TI 01F/00/en Level Measurement silometer FMX 570 Measurement of liquids and bulk solids Suitable for explosion hazardous areas For use with capacitance and hydrostatic probes The

More information

SET Installation and Operating Instructions. Level switch for two sensors

SET Installation and Operating Instructions. Level switch for two sensors Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 20.2.2013 Internet: www.labkotec.fi 1/14 SET-2000 Level switch for two sensors Copyright 2013 Labkotec

More information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/ 3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging

More information

Two-Wire Programmable Transmitter for:

Two-Wire Programmable Transmitter for: TM Smart Process Instrumentation Revision 2 Two-Wire Programmable Transmitter for: Industrial Thermocouple or RTD Temperature Measurements Highlights: Exceptional speed and accuracy Guaranteed measurement

More information

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For oils and fuels Model LF-1 Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run

More information

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes

More information

CAH CARD. user leaflet. 1 of 15. Copyright Issue 12.1 January 2015

CAH CARD. user leaflet. 1 of 15. Copyright Issue 12.1 January 2015 CAH CARD user leaflet 1 of 15 INTRODUCTION The function of the card is to energise a transducer (LVDT, Half-Bridge or Full-Bridge) with a stable a.c. waveform and to convert the output of the transducer

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Issue No.

More information

F2xx & F2xx-XE Megablock Series

F2xx & F2xx-XE Megablock Series technical datasheet technical datasheet Fxx & Fxx-XE Megablock Series passive hubs for Zone & Division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

New Report Indicates AC Inductance/Electrodynamic Dust Detectors May Be Hazardous. Ron Dechene Auburn Systems, LLC Danvers MA 01923

New Report Indicates AC Inductance/Electrodynamic Dust Detectors May Be Hazardous. Ron Dechene Auburn Systems, LLC Danvers MA 01923 New Report Indicates AC Inductance/Electrodynamic Dust Detectors May Be Hazardous Ron Dechene Auburn Systems, LLC Danvers MA 01923 Summary An independent study has concluded that polymer jacketed, or coated,

More information

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output

More information

User's Manual Model SE14 Magnetic Flow Converter

User's Manual Model SE14 Magnetic Flow Converter User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194 DIN Rail Devices Description DIN rail devices serve as low cost signal conditioning modules between the field device and the control system. The new enclosures mounted on the 35 mm standard rail are equipped

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL Version 2.2 MS1016 MTF SERIES VIBRATING PROBES FOR LIQUIDS AND HYC-PKK-312 SWITCHING ISOLATOR INSTALLATION AND OPERATION MANUAL Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire,

More information

SBEx-2S BINARY SEPARATOR

SBEx-2S BINARY SEPARATOR SBEx2S BNARY SEPARATOR accompanying device of group of category (M1), group i category (1), two channels in one rail housing (TS35, width 22.5mm), level ia intrinsically safe input circuits compliance

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information