UTE100 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTE100 NT FMU 100A 3P LL LSIS UL MCCB

Size: px
Start display at page:

Download "UTE100 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTE100 NT FMU 100A 3P LL LSIS UL MCCB"

Transcription

1 PRODUCT CATALOG SUSOL SUPER SOLUTION SELECTION GUIDE UTE00 CATALOG NUMBERING [PRODUCT SELECTION] UTE00 NT FMU 00A 3P LL UL SERIES & FRAME: Susol 00AF PERFORMANCE Rating 80% 00% ka SUFFIX UL : UL 20/ 240Vac E ET 50 N NT 65 AMPERES Vac E ET 50 N NT TERMINALS 480Vac E ET 25 N NT 35 TRIP UNIT FTU: Fixed Thermal, Fixed Magnet POLES LL: Lugs Line/Load Side L : Lugs Line Side 600Y 347Vac E ET 4 N NT 8 FMU: Adj. Thermal, Fixed Magnet MCS: Molded Case Switch : Two 3: Three LO: Lugs Load Side - : Bolt-on 4

2 SUSOL SUPER SOLUTION UL MCCB UTE00 FRAME UTE00 breaker is HACR rated SWD switch duty rating (applied only to 5 and 20A /347Vac or less) HID high intensity discharge lighting rating (5~50A /480Vac or less) UL489 RATINGS BREAKER TYPE NUMBER OF POLES INTERRUPTING CAPACITY (ka rms) AC 50/60Hz INTERRUPTING CAPACITY (ka) DC 20/240V 240V 480V 600Y 347V 250V DC-2P 500V DC-3P UTE00E 2, UTE00N 2, IEC RATINGS BREAKER TYPE NUMBER OF POLES INTERRUPTING CAPACITY(kA rms) AC 50/60Hz, Icu 220/240V 380/45V UTE00E 2, UTE00N 2, Service breaking capacity, Ics (%Icu) 00% Insulation Voltage, Ui Impulse Withstand Voltage, Uimp Utilization Category 750 Vac 8 kvac A DIMENSIONS DIMENSIONS inch (mm) POLES H W D 2-Pole 5.2 (30) 2.0 (5) 3.44 (87.5) 3-Pole 5.2 (30) (76) 3.44 (87.5) TRIP UNIT TYPES THERMAL MAGNETIC REMARKS FTU Fixed Fixed FMU Adjustable, 0.8~ x In Fixed MCS N.A Fixed, 0 x In Magnetic only CIRCUIT BREAKER Ampere Rating, In WITH FTU TRIP UNIT (FIXED THERMAL, FIXED MAGNETIC) 50kA at 20/240V, 50kA at 240Vac 65kA at 20/240V, 65kA at 240Vac 2-Pole 3-Pole 2-Pole 3-Pole 5A UTE00 E FTU 5 2 UTE00 E FTU 5 3 UTE00 N FTU 5 2 UTE00 N FTU A UTE00 E FTU 20 2 UTE00 E FTU 20 3 UTE00 N FTU 20 2 UTE00 N FTU A UTE00 E FTU 25 2 UTE00 E FTU 25 3 UTE00 N FTU 25 2 UTE00 N FTU A UTE00 E FTU 30 2 UTE00 E FTU 30 3 UTE00 N FTU 30 2 UTE00 N FTU A UTE00 E FTU 35 2 UTE00 E FTU 35 3 UTE00 N FTU 35 2 UTE00 N FTU A UTE00 E FTU 40 2 UTE00 E FTU 40 3 UTE00 N FTU 40 2 UTE00 N FTU A UTE00 E FTU 45 2 UTE00 E FTU 45 3 UTE00 N FTU 45 2 UTE00 N FTU A UTE00 E FTU 50 2 UTE00 E FTU 50 3 UTE00 N FTU 50 2 UTE00 N FTU A UTE00 E FTU 60 2 UTE00 E FTU 60 3 UTE00 N FTU 60 2 UTE00 N FTU A UTE00 E FTU 70 2 UTE00 E FTU 70 3 UTE00 N FTU 70 2 UTE00 N FTU A UTE00 E FTU 80 2 UTE00 E FTU 80 3 UTE00 N FTU 80 2 UTE00 N FTU A UTE00 E FTU 90 2 UTE00 E FTU 90 3 UTE00 N FTU 90 2 UTE00 N FTU A UTE00 E FTU 00 2 UTE00 E FTU 00 3 UTE00 N FTU 00 2 UTE00 N FTU

3 PRODUCT CATALOG SUSOL SUPER SOLUTION CIRCUIT BREAKER Ampere Rating, In WITH FTU TRIP UNIT (FIXED THERMAL, FIXED MAGNETIC) 25kA at 480V, 4kA at 600Y 347Vac 35kA at 480V, 8kA at 600Y 347Vac 2-Pole 3-Pole 2-Pole 3-Pole 5A UTE00 E FTU 5 2 UTE00 E FTU 5 3 UTE00 N FTU 5 2 UTE00 N FTU A UTE00 E FTU 20 2 UTE00 E FTU 20 3 UTE00 N FTU 20 2 UTE00 N FTU A UTE00 E FTU 25 2 UTE00 E FTU 25 3 UTE00 N FTU 25 2 UTE00 N FTU A UTE00 E FTU 30 2 UTE00 E FTU 30 3 UTE00 N FTU 30 2 UTE00 N FTU A UTE00 E FTU 35 2 UTE00 E FTU 35 3 UTE00 N FTU 35 2 UTE00 N FTU A UTE00 E FTU 40 2 UTE00 E FTU 40 3 UTE00 N FTU 40 2 UTE00 N FTU A UTE00 E FTU 45 2 UTE00 E FTU 45 3 UTE00 N FTU 45 2 UTE00 N FTU A UTE00 E FTU 50 2 UTE00 E FTU 50 3 UTE00 N FTU 50 2 UTE00 N FTU A UTE00 E FTU 60 2 UTE00 E FTU 60 3 UTE00 N FTU 60 2 UTE00 N FTU A UTE00 E FTU 70 2 UTE00 E FTU 70 3 UTE00 N FTU 70 2 UTE00 N FTU A UTE00 E FTU 80 2 UTE00 E FTU 80 3 UTE00 N FTU 80 2 UTE00 N FTU A UTE00 E FTU 90 2 UTE00 E FTU 90 3 UTE00 N FTU 90 2 UTE00 N FTU A UTE00 E FTU 00 2 UTE00 E FTU 00 3 UTE00 N FTU 00 2 UTE00 N FTU 00 3 Ampere Rating, In WITH FMU TRIP UNIT (ADJUSTABLE THERMAL, FIXED MAGNETIC) 50kA at 20/240V, 50kA at 240Vac 3-Pole 65kA at 20/240V, 65kA at 240Vac 3-Pole Thermal range 25A UTE00 E FMU 25 3 UTE00 N FMU A 40A UTE00 E FMU 40 3 UTE00 N FMU A 60A UTE00 E FMU 60 3 UTE00 N FMU A 80A UTE00 E FMU 80 3 UTE00 N FMU A 00A UTE00 E FMU 00 3 UTE00 N FMU A Ampere Rating, In 25kA at 480V, 4kA at 600Y 347Vac 3-Pole 35kA at 480V, 8kA at 600Y 347Vac 3-Pole Thermal range 25A UTE00 E FMU 25 3 UTE00 N FMU A 40A UTE00 E FMU 40 3 UTE00 N FMU A 60A UTE00 E FMU 60 3 UTE00 N FMU A 80A UTE00 E FMU 80 3 UTE00 N FMU A 00A UTE00 E FMU 00 3 UTE00 N FMU A MOLDED CASE SWITCH WITH MCS TRIP UNIT Ampere Rating, In 50kA at 20/240V, 50kA at 240V 65kA at 20/240V, 65kA at 240V 2-Pole 3-Pole 2-Pole 3-Pole 00A UTE00 E MCS 00 2 UTE00 E MCS 00 3 UTE00 N MCS 00 2 UTE00 N MCS 00 3 Ampere Rating, In 25kA at 480V, 4kA at 600Y 347Vac 35kA at 480V, 8kA at 600Y 347Vac 2-Pole 3-Pole 2-Pole 3-Pole 00A UTE00 E MCS 00 2 UTE00 E MCS 00 3 UTE00 N MCS 00 2 UTE00 N MCS

4 SUSOL SUPER SOLUTION UL MCCB ACCESSORIES FOR UTE00 MECHANICAL LUGS MAXIMUM BREAKER AMPERES TERMINAL BODY MATERIAL WIRE TYPE ORDERING TYPE AL00TE 5-00A Lug 00A Aluminum Cu/Al AL00TE INNER ACCESSORIES DESCRIPTION CONTROL VOLTAGE Auxiliary Switch, AX Alarm Switch, AL AX + AL Shunt Trip, SHT AC/DC 2V AC/DC 24V AC/DC 48V AC/DC 60V AC/DC 00~30V AC/DC 200~250V AC 380~450V AC 440~500V Undervoltage Trip, UVT AC/DC 24V AC/DC 48V AC/DC 00~0V AC/DC 200~220V AC 380~440V AC 440~480V AX or AL or AX+AL UVT or SHT or AX or AL or AX+AL Type Left(R) Right(T) AX AL AX+AL SHT UVT - Applicable in indicated pole position-not synchronous - 2P : Right only PADLOCKING DEVICE DESCRIPTION Lock in OFF position PL0 PLATE HANDLE LOCKING DEVICE <Pad Lock> DESCRIPTION Lock in OFF or ON position PHL0 <Plate Handle Lock> MECHANICAL INTERLOCKING DEVICE DESCRIPTION For 3-Pole breaker MIT03 ENCLOSURE <Mechanical Interlock> ENCLOSURE DIMENSION (W X H X D) inch(mm) 8.27(20) x 7.3(439.4) x 4.0(0.6) - H W D 7

5 SUSOL SUPER SOLUTION PRODUCT CATALOG ROTARY OPERATING HANDLES DESCRIPTION TYPE Directly Mounted NEMA Type DH-0 NEMA Type REH-0 NEMA Type REH-0C NEMA Type, 2 EHU-0 Extended (Door-Mounted) NEMA Door-Mounted NEMA Type 3, 3R, 4 EHV-0 NEMA Type 3, 4, 4X EHX-0 NEMA Type, 2 EHU-0C NEMA Type 3, 3R, 4 EHV-0C NEMA Type 3, 4, 4X EHX-0C <DH-0> <REH-0> <REH-0C> FLANGE HANDLES WITH CABLE OPERATING MECHANISM DESCRIPTION TYPE Cable operating mechanism (without cable) COM-0 NEMA Type, 2, 3, 3R, 4 Standard type handle (with operating mechanism) FHU-S NEMA Type 4, 4X FHX-S 36 inch FH inch FH inch FH inch FH2-72 Cable <EHU-0> <EHU-0C> FLANGE HANDLES WITH VARIABLE-DEPTH OPERATING MECHANISM DESCRIPTION TYPE Variable depth operating mechanism with threaded-rod and handle Standard type handle with operating mechanism <COM-0> VDM-0 NEMA Type, 2, 3, 3R, 4 FHU-S NEMA Type 4, 4X FHX-S <VDM-0> Description Directly Mounted Door Mounted * * Only 3 Pole 8 * - Flange Handle with Variable Depth Mechansm - - * NEMA Type NEMA Type, 2, 3, 3R, 4, 4X Flange Handle with Cable Operation Mechansm

6 SUSOL SUPER SOLUTION UL MCCB UTE00 CHARACTERISTIC This curve is to be used for application and coordination purposes only. All time/current characteristic curve data is based on 40 C ambient cold start UTE00 FTU, FMU (5~00A) Minutes Thermal Trip Times FTU:Ir= x In FMU:Ir=0.8~xIn - 60~00A - 40~50A - 5~30A Operating time Second 0. Magnetic Trip In:5A -> Im=400A In:20A -> Im=400A In:45A -> Im=800A In:25A -> Im=400A / In:50A -> Im=800A In:30A -> Im=400A / In:60A -> Im=800A In:35A -> Im=400A / In:70A -> Im=800A In:90A -> Im=000A In:40A -> Im=400A / In:80A -> Im=800A In:00A -> Im=000A Tolerance : 80~30% Multiples of rated current (x In) RATING UTE00 2P/3P FTU MAG TRIP (80%~30%) 400A FMU RATING UTE00 RATING MAG TRIP 3P RANGE (80%~30%) 25 20~25A 40 32~40A 400A 60 48~60A 80 64~80A 800A 00 80~00A 000A A A 99

7 PRODUCT CATALOG SUSOL SUPER SOLUTION UTE00 CHARACTERISTIC This curve is to be used for application and coordination purposes only. All time/current characteristic curve data is based on 40 C ambient cold start. UTE00 MCS (00A) Minutes Thermal withstand Operating time Second 0. Magnetic Trip MCS:Im=0 x In Tolerance : 80~30% Multiples of rated current (x In) RATING UTE00 MCS (2P/3P) MAG TRIP (80%~30%) (0 x In) A 00

8 SUSOL SUPER SOLUTION UL MCCB DIMENSIONS UTE00 CIRCUIT BREAKERS UTE00 2P Circuit Breaker [Lug type] Dimension: inch[mm] 5.2 [30] 4.33 [0] 3.94 [00] 3.9 [8].77 [45] ø 0.7 [ø 4.2] 0.98 [25] 0.49 [2.5] UTE00 2P Circuit Breaker [Busbar type] 5.2 [30] 4.33 [0] 3.94 [00] 3.9 [8].77 [45] ø 0.7 [ø 4.2] Section B-B 2.0 [5] 0.98 [25] 0.49 [2.5] Mounting hole Trip button 0.6 [4] [25.5] 0.66 [6.7] 3.58 [9] 3.44 [87.5] 3.29 [83.5] 2.8 [7.5] 2.74 [69.5] 2.0 [5] Mounting hole Trip button 0.6 [4] [25.5] 0.66 [6.8] 0.47 [2] 0.96 [24.3] 3.58 [9] 3.44 [87.5] 3.29 [83.5] 0. [2.5] 2.8 [7.5] 2.74 [69.5] 0.8 [20.6] See Detail A 0.75 [9] Detail A 0.22 [5.7] ø0.9 [ø4.8] (0-24 TERMIANL NUT) 0.38 [9.6] 0.22 [5.6] 0.47 [2] 0.96 [24.3] B B 0.9 [23.] See Detail A Detail A 0.38 [9.6] 25

9 PRODUCT CATALOG SUSOL SUPER SOLUTION DIMENSIONS UTE00 CIRCUIT BREAKERS UTE00 3P Circuit Breaker [Lug type] Dimension: inch[mm].97 [50] 0.98 [25] 5.2 [30] 4.33 [0] 3.94 [00] 3.9 [8].77 [45] 0.98 [25] ø 0.7 [ø 4.2].97 [50] 0.98 [25] 5.2 [30] 4.33 [0] 3.94 [00] 3.9 [8].77 [45] 0.98 [25] ø 0.7 [ø 4.2] 3.58 [9] 3.44 [87.5] 3.29 [83.5] 2.8 [7.5] 2.74 [69.5].5 [38].5 [38] Trip button Mounting hole 0.6 [4] 0.66 [6.8] [25.5] 0.47 [2] 0.96 [24.3] 3.58 [9] 3.44 [87.5] 0. [2.5] 3.29 [83.5] 2.8 [7.5] 2.74 [69.5] 0.8 [20.6] See Detail A 0.75 [9] Detail A UTE00 3P Circuit Breaker [Busbar type] 0.22 [5.7] Section B-B 0.38 [9.6] ø0.9 [ø4.8] (0-24 TERMIANL NUT) 0.22 [5.6] Trip button Mounting hole 0.6 [4] 0.66 [6.8] [25.5] 0.47 [2] 0.96 [24.3] B B 0.9 [23.] See Detail A Detail A 0.38 [9.6] 26

10 SUSOL SUPER SOLUTION UL MCCB UTE00 Circuit Breakers Mounting Dimension: inch[mm] 0.5 [2.5] 0.5 [2.5] 4.33 (0) 4.33 (0) [2P] #6-32 UNC Tap (2 Holes) [3P] #6-32 UNC Tap (2 Holes) UTE00 Circuit Breakers Door Cutouts Cutouts B Cutouts A 2.09 [53] 0.55 [4] 3.07 [78].89 [48].6 [4].6 [4] 3.29 [83.5] 3.44 [87.5].06 [27] Cutouts A Cutouts B [2P] Cutouts B [3P] UTE00 Directly Mounted Rotary Operating Handle [DH-0] ø 0.7 [ø 4.2] 3.94 [00] 2. [53.5] 4.06 [03] 4.52 [4.9] 4.78 [2.3] 6.4 [62.8].97 [50].4 [29] 0.28 [7] 3.63 [92.] 0.28 [7] 5.24 [33] 5.24 [33] 2.63 [66.9] 5.28 [34.2] 0.08 [2] Cutouts A [IN] [OUT] [IN] [OUT] 0.47 [2] 0.3 [8] 0.28 [7] 4.3 [09.6] 4.3 [09.6] 27

11 PRODUCT CATALOG SUSOL SUPER SOLUTION DIMENSIONS UTE00 CIRCUIT BREAKERS UTE00 Door-Mounted Rotary Operating Handle [REH-0] Dimension: inch[mm] 0.08 [2.] [Ø 5.2] Ø 0.2 Ø 2.0 [Ø 5] 0.92 [23.3] 2.3 [54].85 [47] 6.5 [56.3] 8.2 [206.3] 28.7 MAX(SHAFT MAX 24) [729.8 MAX(SHAFT MAX 609.6)] (Cutouts A) 2.28 [58] 0.93 [23.5].85 [47] UTE00 Door-Mounted Rotary Operating Handle [REH-0C] 0.08 [2.] 2-Ø [Ø 6] CL 2.3 [54].85 [47] 0.73 [8.5] 4.3 [09.5] 7.62 [93.5] 28.0 MAX(SHAFT MAX 24 [7.3 MAX(SHAFT MAX 609.6)] (Cutouts A) 2.28 [58] 0.93 [23.5] Ø 2.09 [Ø 53].85 [47] 0.75 [9] 0.93 [23.5] UTE00 NEMA Door-Mounted Rotary Operating Handle [EHU-0, EHX-0] 0.08 [2.] Ø.97 [Ø 4.5] Ø [90] 5.28 [34.2] [Ø 50] 0.02 [0.5].33 [33.9] 2.68 [68.] 6.5 [56.3] 8.2 [206.3] 27.7 MAX(SHAFT MAX 24) [704.4 MAX(SHAFT MAX 609.6)] (Cutouts A) 3.53 [89.7] 5.94 [50.8] 0.0 [0.3].36 [34.5] 2.69 [68.3] 0.43 [0.9].35 [34.2] 28

12 SUSOL SUPER SOLUTION UL MCCB UTE00 NEMA Door-Mounted Rotary Operating Handle [EHU-0C, EHX-0C] Dimension: inch[mm] Ø 2.05 [Ø 52] 3.55 [90.2] 4.3 [09.5] 7.62 [93.5] 27.0 MAX(SHAFT MAX 24 [685.9 MAX(SHAFT MAX 609.6)] (Cutouts A) 4- Ø 4-Ø 0.2 [ 5] 4.7 [9.5].69 [43] 4.57 [6] [84] [22] 3.3 [84] 2.85 [72.4] 3.3 [84] 8.7 [220.9] 3.3 [84] 2.69 [68.3] 3.96 [00.5].69 [43] 4.49 [4.] 9.55 [242.5] 0.78 [273.7] 0.34 [262.6] 9.55 [242.5] 0.78 [273.7] 0.34 [262.6] 2.68 [68] 0.73 [8.5].34 [34] 3.53 [89.7] 5.94 [50.9] 0.75 [9] 0.43 [].34 [34] 2.68 [68] 0.43 [] UTE00 Flange-Mounted Cable Operating Handle [COM-0 + FHU, X-S + Cable] UTE00 Flange-Mounted Variable-Depth Operating Handle [VDM-0 + FHU, X-S] 29

Technical Data Accessories MCCBs Ex9M.

Technical Data Accessories MCCBs Ex9M. Auxiliary and signal contact units AX21, AL21 Contact units for auxiliary and signal contact functions are suitable for both M1 and M2 frame sizes It is possible to use ap to two units of AX21 plus 1 unit

More information

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 Presentation Thermal-magnetic motor circuit-breakers types GV, GV and GV7 GV-ME, GV-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control

More information

Bulletin 140U Molded Case Circuit Breakers

Bulletin 140U Molded Case Circuit Breakers Bulletin 40U Multitap End Cap Optional Optional Optional 40U-J-MTLA 40U-J-MTL6A 40U-J-ECM Aluminum Aluminum Molded Housing /4 screw /4 screw lb-in lb-in.6 N m.6 N m Cu/Al Cu/Al 60/7 C 60/7 C () (6) (A)

More information

PowerPact H-, J-, and L-Frame Circuit Breakers General Information. Vibration. Electromagnetic disturbances. Tropicalization

PowerPact H-, J-, and L-Frame Circuit Breakers General Information. Vibration. Electromagnetic disturbances. Tropicalization General Information Vibration PowerPact H-, J-, and L-frame devices resist mechanical vibration. Tests are carried out in compliance with standard UL 489 SA and SB for the levels required by merchant-marine

More information

page 2 of 86 Report reference No:

page 2 of 86 Report reference No: articulars: test item vs. test requirements 3. Classification 3.1. Utilization category: (A or B)... : A 3.2. Interruption medium: (air, vacuum, gas Break)... : Air 3.3. Design: (open construction, moulded

More information

Plug-In Circuit Breakers

Plug-In Circuit Breakers Plug-In Circuit Breakers Types QP, QPH, and HQP with INSTA-WIRE, QN and QNH 14 1-POLE (120V AC) 10 MP110 15 MP115 MP115KH MP115KM 20 MP120 MP120KH MP120KM 25 MP125 MP125KH MP125KM 30 MP130 MP130KH MP130KM

More information

Ampere Rating LAL MAL* NAL. 2-pole. 3-pole. Catalog No. Price $ QO300 QOU300 QO3000 QOU3000 QOU30001

Ampere Rating LAL MAL* NAL. 2-pole. 3-pole. Catalog No. Price $ QO300 QOU300 QO3000 QOU3000 QOU30001 MAG-GARD Motor Circuit Protector Class, 8, 6, 68 Instantaneous trip magnetic onl circuit breakers have a single adjustment which simultaneousl sets the magnetic trip level of each individual pole. MAG-GARD

More information

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance

More information

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A Load break switches standards UL and CSA The solution for Load break switches sircm_1_a_1_cat > Power distribution Strong points Function Rotary switch SRCO M 3 x 1 A SRCO M load break switches are compact

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >

More information

CB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C

CB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C age 1 of 109 Report No.600332-04/01 TEST REORT Low-voltage switchgear and controlgear art 2: Circuit - breakers Report Reference No....: 600332-04/01 Tested by (name+signature)...:... Witnessed by (name+signature)...:...

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD)

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD) Acti 9 Acti 9 circuit reakers from 0.5 to 125 A 056903N-32_SE.eps 056806N-28_SE.eps PB104440_28.eps PB107141_28.eps Acti 9 circuit reaker C120N Numer of poles 1 2-3-4 Electrical characteristics Rated current

More information

Page 13-2 Page Page 13-7

Page 13-2 Page Page 13-7 Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,

More information

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Maintenance/Connection/Installation Service life C/O cyclesx1000

Maintenance/Connection/Installation Service life C/O cyclesx1000 EasyPact MVS 2016 CPB100000 CPB100014 Circuit breaker. Switch disconnector. Common characteristics Number of poles Rated insulation voltage (V) Impulse withstand voltage (kv) Rated operational voltage

More information

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0

More information

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87 Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................

More information

$

$ ircuit reakers or I-LIN Panelboards and Switchboards lass 0, 5, 70, 830 8 PNLORS 8-32 LI3 7.5 in (190 mm) L 7.5 in (190 mm) M, MH 2- and 3-Pole 9 in (229 mm) N, N 2- and 3-Pole 15 in (381 mm) Square ll

More information

Technical catalogue. Emax Low voltage air circuit-breakers. Hotline:

Technical catalogue. Emax Low voltage air circuit-breakers.   Hotline: Technical catalogue Emax Low voltage air circuit-breakers www.alobitanbd.com Hotline: 01711548558 PAGE : 02 The new Emax have received innumerable international certifications and approval by the major

More information

04 Page. MCCBs characteristics 94. MCCBs & accessories selection guide 96. MCCBs x MCCBs x MCCBs h

04 Page. MCCBs characteristics 94. MCCBs & accessories selection guide 96. MCCBs x MCCBs x MCCBs h This section includes moulded case circuit breakers, manual and automatic transfer switches and load break switches which are utilised for the switching, protection and distribution of low voltage installations.

More information

TEST REPORT IEC Low-voltage switchgear and controlgear - Part 2: Circuit-breakers

TEST REPORT IEC Low-voltage switchgear and controlgear - Part 2: Circuit-breakers Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and controlgear - art 2: Circuit-breakers Report Reference No.... : 3305316.50 Date of issue... : 2013-09-17 Total number

More information

Low voltage circuit breakers

Low voltage circuit breakers Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers A-4. Technical information TD & TS MCCB Index Temperature derating Power dissipation / Resistance Application Primary use of transformer

More information

Miniature circuit breakers. Residential current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures

Miniature circuit breakers. Residential current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures .2..4.5.6.7 Technical data Series ME07 Standard range S, S, 0/690V/AC High performance range H, 0/690V/AC High performance range H/S, 000V/AC Disconnecting switch MET DC circuit breaker ME 6T up to 0V/DC

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses BS884 Fuses 6x27, 2X6x27, 250 VAC Extremely high breaking capacity fuses: protection of power semiconductors as per IEC standard 60269.1 and 4 250 V voltage COMPLYING WITH IEC gr class (s from 50 to 50

More information

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition

More information

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv) Outdoor Transmission (69 kv through 230 kv) Detailed Functional Specification Guide 1.0 GENERAL 1.01 The circuit-switcher shall conform to the following specification. 1.02 The circuit-switcher shall be

More information

AEG Low Voltage Component

AEG Low Voltage Component AEG Low Voltage omponent Technology transfers reliable power We are striving to create a peaceful and comfortable life for you. AEG: We believe that power system can be very simple. Main distribution system

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

INTERPLANT STANDARD - STEEL INDUSTRY

INTERPLANT STANDARD - STEEL INDUSTRY INTERPLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR MOULDED - CASE CIRCUIT-BREAKER FOR VOLTAGES NOT EXCEEDING 1000 V ac OR 1500 V dc (FIRST REVISION) IPSS:1-04-004-11 IPSS BASED ON IS/IEC 60947(Part

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

Ledex Tubular Linear Solenoids

Ledex Tubular Linear Solenoids Ledex Tubular Linear Solenoids Force lbs. (newtons) 10 (.) (35.5) 6 (6.69) (17.79) 10% Duty Cycle 70W 5% Duty Cycle W 50% Duty Cycle 1W 100% Duty Cycle 7W saia-burgess Solenoids 1-00-99-9 www.saia-burgess-usa.com/ledex

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947 Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

Components for safety applications

Components for safety applications Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages

More information

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Semiconductor (AC) fuses

Semiconductor (AC) fuses Main characteristics Recognized 650 to 300VAC / 63 to 2800A. Exceptionally low I 2 T, Watt losses. Non-magnetic construction, highly reliable low voltage. Indicator system. Conformity to UL, CSA investigated,

More information

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit DPX TM MCCBs Description Cat. nos. ` / Pack DPX TM MCCBs Description Cat. nos. ` / Pack Auxiliary contact / Fault signalling contact DPX 125,160,250 ER 0261 60 804 1/24 250, 630, 1600, 1250 Under voltage

More information

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH 4-...-C 1) NZM6B.../ZM6A...- Frame size A 80 125 125 IEC 60 947-2 Electrical Ratings Rated impulse withstand voltage U imp V 8000 8000

More information

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Miniature circuit-breakers S 280 UC series. System pro M. Technical data Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum

More information

SB 50 Connectors - up to 120 amps

SB 50 Connectors - up to 120 amps Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP s two pole SB connectors set the standard for DC power distribution and battery connections. connectors feature a one

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

Safety switches with slotted hole lever

Safety switches with slotted hole lever Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the

More information

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations Industrial Areamaster Generation HL LED Luminaire Type R,, X Applications Powerful, efficient weatherproof lighting for applications such as: Security lighting Production facilities Warehouses Processing

More information

System Components and Accessories

System Components and Accessories OutBack Panel Mount Breakers Panel mounted hydraulic-magnetic type breakers that can be used for DC sources, inverters or load circuits. Model Current Voltage Branch Terminals Width Rating Rating Circuit

More information

technical information

technical information technical information protection devices 192 circuit protection principle 194 circuit breakers characteristics 200 moulded case circuit breakers (MCCB) 205 prospective fault current 208 selectivity and

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

Mould circ. Moulded case circuit-breakers

Mould circ. Moulded case circuit-breakers Mould circ Moulded case circuit-breakers Moulded case circuit-breakers Tmax Contents Power distribution circuit-breakers Technical Data... 7/6 Ordering details Reading information... 7/15 Tmax T1... 7/20

More information

B. Manufacturers: Square-D, G.E. or Westinghosue.

B. Manufacturers: Square-D, G.E. or Westinghosue. SECTION 16470 - PANELBOARDS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

Submittal Transmittal

Submittal Transmittal Commonwealth Engineers, Inc. 7256 Company Drive Indianapolis IN 46237 United States Submittal Transmittal PROJECT: SUBJECT: Waynetown - Water-Strmwtr Imprv-Div A J13046-A DS-23-01 A_Engine Generators &

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1, EN50041 UL and C-UL listed T4011 Heavy-duty Metal Body Safety Interlock Switch Rugged enclosure the all metal housing and stainless steel actuator

More information

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC) Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,

More information

Prüf-Nr./Q-Nr.: Ceft f cate No., Dienststelle: Department: Ort Place: Anlagen: Enclosures:

Prüf-Nr./Q-Nr.: Ceft f cate No., Dienststelle: Department: Ort Place: Anlagen: Enclosures: SIEMENS Prüf-Nr./Q-Nr.: Ceft f cate No., Dienststelle: Department: Ort Place: Anlagen: Enclosures: 3267 DF CP R&D V 3 / Drutschmann Ambero Tag: - Date Summary:3267 2014-11-11 Typprtibescheinigung I T p

More information

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable: Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

Technical features table for miniature circuit-breakers SH 200 Series

Technical features table for miniature circuit-breakers SH 200 Series Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution

More information

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A High performance circuit breaker mcb and combined mcb with remote controls LV Distribution Products 2-63A Mini motorized circuit breaker The mini-series of motorized circuit breakers operates both locally

More information

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole MULTIBLOC 4a.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS Touch protection IP 20 Safe on load connection/disconnection in accordance with IEC 609473 The production

More information

DISCONNECT SWITCHES. UL Listed CSA Certified

DISCONNECT SWITCHES. UL Listed CSA Certified POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole

More information

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE 87045 LIMOGES Cedex France Tel: (+33) 05 55 06 87 87 Fax: (+33) 05 55 06 88 88 DRIVIA cabinets CONTENTS NTS PAGES 1. Description, use....1 2. Range, equivalence table...1 3. Dimensions...1 4. General characteristics...2

More information

L-Series. AC or DC Miniature Molded Case Circuit Breakers. UL489 Listed Circuit Breakers UL 489 UL 508

L-Series. AC or DC Miniature Molded Case Circuit Breakers. UL489 Listed Circuit Breakers UL 489 UL 508 UL 489 ANNEX UL 077 UL 077 L-Series AC or DC Miniature Molded Case UL489 Listed Available in AC and DC models DIN Rail Mounted 7.5mm width Thermal Magnetic 40V, 480Y/77V AC, 50/60Hz 5VDC ( pole); 50VDC

More information

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3 CONTENTS COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3 CONSTRUCTION... 4 ~ 5 A. CORE AND FRAME... 4 B. COIL... 5 C. TEMPERATURE INDICATOR... 5 CHARACTERISTICS... 6 MANUFACTURING FACILITIES...

More information

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers .5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings

More information

Zelio Plug-In Relays. RXG interface relays. Catalog

Zelio Plug-In Relays. RXG interface relays. Catalog Zelio Plug-In Relays Catalog 204 Contents Zelio Plug-In Relays bbintroduction.... 3 bbspecifications.................................................... 4 bbreferences... 7 bbdimensions.... 0 bbwiring

More information

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System Technical Data TD008010EN Supersedes February 2016 Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System The information below is taken directly from the National Electrical CodeT (NEC)

More information

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole MULTIBLOC 00.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 00.ST8 comprises NH fuse switch disconnectors for 160A. They are designed for bottom

More information

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts ALPHA AS Modular Distribution Boards /2 Introduction Unequipped Distribution Boards /4 Modular distribution boards / Add-on parts Assembly Kits for Unequipped Distribution Boards /6 8GK4 assembly kits

More information

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Medium-Voltage Switchgear Catalog HA 40.2 2009 Answers for energy. -HA40-111.eps -HA40-110.eps -HA40-109.eps -HA40-112.eps

More information

StatiVolt. Inverter UPS Systems. Features. Contents

StatiVolt. Inverter UPS Systems. Features. Contents Redundant, clean, sine-wave AC power ensures a high availability of mission-critical safety devices, instrumentation, alarms, controls and computers. Robust, StatiVolt UPS Systems are designed and built

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C.3 General characteristics. C.4 Fixed circuit breaker. C.5 Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C.3 General characteristics. C.4 Fixed circuit breaker. C.5 Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary.3 General characteristics.4 Fixed circuit breaker.5 Withdrawable circuit breakers.6 haracteristics.7 RMS 7: protection and control unit.10 RMS 9: protection and

More information

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4 /0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors

More information

TEST REPORT IEC Low-voltage switchgear and controlgear - Part 2: Circuit-breakers

TEST REPORT IEC Low-voltage switchgear and controlgear - Part 2: Circuit-breakers Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and controlgear - art 2: Circuit-breakers Report Reference No.... : 2168871.52 Date of issue... : 2014-12-09 Total number

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

SAMSUNG ELECTRO-MECHANICS CO., LTD

SAMSUNG ELECTRO-MECHANICS CO., LTD Model Name : Features : ㅡ Suitable for LED lighting application ㅡ UL8750, UL1310 Class 2 ㅡ For use in Dry and Damp Location ㅡ Full-protection provided: OCP/OVP/OTP/SCP ㅡ 0-10V Dimming Control ㅡ IP67 ㅡ

More information

CX-Series. Circuit Breaker

CX-Series. Circuit Breaker CX-Series Circuit Breaker Carling Technologies is proud to introduce the CX-Series circuit breaker, which features a unique and innovative patent pending arc quenching configuration that allows the breaker

More information

NEMA Contactor and Starter Specifications

NEMA Contactor and Starter Specifications Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental

More information

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg Contactors & Relays Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators Pg 223 230 231 232 232 Contactors & Relays Contactor - GMC Series 3 Pole (240V) AC 1 Rati

More information

Detecting Devices. 8/2 Introduction

Detecting Devices. 8/2 Introduction Siemens AG 29 Detecting Devices /2 Introduction 3SE5, 3SE2, 3SE3 Position Switches /4 General data /11 3SE5, plastic and metal enclosures /2 3SE2, plastic enclosures /26 3SE2, metal enclosures /36 3SE3,

More information

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED SECTION 16280 LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED PART 1 - GENERAL 1.1 SUMMARY This specification defines the requirements for active harmonic filter systems in order to meet IEEE-519-2014

More information

Electrical Description

Electrical Description History of this Document Rev. no.: Date: Description of change 0 First edition 2 2003-10-08 Section 3: The rated power of the transformer can be increased by 40% if they are equipped with 6 fans for forced

More information

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING Aluminium 1000A 1250A 1600A 2000A 2250A 2500A 3200A 4000A 4500A R 95503111 95503131 95503131 95503141 95513111 95513131 95513131 95513141 95513151 L 95503211 95503231 95503231 95503241 95513211 95513231

More information

Stabilized Differential Relay SPAD 346. Product Guide

Stabilized Differential Relay SPAD 346. Product Guide Issued: July 1998 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault

More information

A9 R Range Family Code Internal code Poles Code Rating (A) Code Acti 9 (A9) iid R

A9 R Range Family Code Internal code Poles Code Rating (A) Code Acti 9 (A9) iid R Earth leakage protection Principle of catalogue numers A9 R 15 2 63 Range Family Code Internal code Poles Code Rating (A) Code Acti 9 (A9) iid R 0 0 0 00 Vigi ic60 V 1P 1 0.5 70 ic60 F 2P 2 0.75 71 ik60

More information

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127 Connection systems Section five Isobar 4 Evo MCB pan assemblies 122 1 Mulitclip busbar and Polybloc 126 Comb busbars 127 Terminals and installation accessories 128 129 121 Isobar 4 Evo MCB pan assemblies

More information