1 Starters + Enclosed Product General escription... 2 atalog Number oding... 4 Enclosure Ratings... 6 The Orange Express Program... 8 ustom ontrol Panels Fractional anual Starters KWKstarters Technical nformation (Online) Wiring iagrams imensions Enclosed ontactors Reversing ontactors Single-Phase ontactors NEA Labeled Lighting ontactors Starters & Enclosed Products Non-ombination otor Starters Reversing Single-Phase NEA Labeled ombination Starters NEA Labeled Explosion-Proof Starters Accessories - Field nstallable ulti-speed Starters Reduced Voltage Starters Pump ontrollers Simplex ontrollers NEA Labeled uplex ontrollers Accessories & odifications oil & Overload Relay odes odifications - Factory Assembled Technical nformation & imensions (Online) ontrol Power Sizing Wiring iagrams Enclosure imensions

2 Starters & Enclosed Products otor Starters and Enclosed Product Open & Enclosed pre-wired motor starters and enclosed contactors for any application KWKstarters n addition to selling open components, Sprecher + Schuh also offers a full array of preassembled and enclosed products ready to install when they reach your dock. Standard or customized The cataloged products in this section comprise Sprecher + Schuh s standard offerings. n most cases, engineering drawings and bills-of-material have already been created and assembly procedures have been standardized. Generally speaking, lead times are shorter on these standard items. Fractional anual Starters Enclosed contactors agnetic motor starters KWKstarters ombination starters Explosion-proof starters ulti-speed starters Reduced voltage starters Pump controllers Softstarters (see Section ) Type E/F combination controllers (see Section F) Your sales representative and our Engineering department will also work with you to customize any of our standard pre-assembled or enclosed products to suit your exact specifications. Any combination of enclosure types, pilot devices, control power transformers, meters and other modifications can be combined to provide exactly the panel you need. UL/SA approved shop Sprecher + Schuh s assembly operations are UL Approved UL508A and SA certified. This means, upon customer request, we can build UL 508A Listed and SA compliant panels that satisfy the most rigorous UL inspection. Regardless of whether your panel has a UL508A Listing, panels built by Sprecher + Schuh adhere to UL mandated design and wiring standards. Built with quality and pride Every panel built by Sprecher + Schuh is meticulously designed and constructed. Where possible, all panels are laid out with generous wiring space. ontrol wiring is neatly bundled and tied to the back pan. Outsourced components are industrial control Enclosed ontactor Enclosed Non-combination Starter Fusible ombination Starter 2

3 uplex Pump ontrol quality from name brand manufacturers. ontrol wiring and device function is electrically tested before the panel leaves our facility. SO 9001 and ATEX ertified ircuit Breaker ombination Starter Pump ontrol Panel Starters & Enclosed Products Sprecher + Schuh is committed to a quality system, focused on customer solutions. This is achieved through superior products and services, excellent customer service, technical expertise, supplier partnerships, and industry leadership. Our facility is SO 9001 certified. That was the catalyst in allowing Sprecher + Schuh to obtain Atmospheres Explosives certification (ATEX). ATEX certification permits us to build explosion-proof equipment and panels to be supplied across the European Union, including anada. Explosion Proof Non-combination Starter Part-Winding Starter ulti-speed Starter Wye-elta Starter 3

4 atalog Number oding Standard Starters and Enclosed ontactors FS and KWKstarters do not use these principles AT ontactors or Starter Type ontactor Size oil ode (or PT) Starters & Enclosed Products A AT BT ATN BTN AU BU AUT BUT AUTN Non-reversing ontactor Starter Starter (Single Phase) Starter (NEA- Three Phase) Starter (NEA- Single Phase) Reversing Reversing ontactor Reversing ontactor (Single Phase) Reversing Starter Reversing Starter (Single Phase) Reversing Starter (NEA) Small - Series A7 ➊ 7-9(E) 7-12(E) 7-16(E) 7-23(E) 7-30(E) 7-37(E) 7-43(E) 7-55(E) 7-60() 7-72() 7-85() 7-97() A 24Z W E, 12 24E, 24 24W 36E 48E, E, E, 220 A/ 24W 48W 120W 480W AZTT AZHT AETT AEHT AAT AYT APWT APT APTN APT ulti-speed ultispeed-two Wind. (onts/var TQ) ultispeed-two Wind. (onst. HP) ultispeed-one Wind. (onts/var TQ) ultispeed-one Wind. (onst. HP) Reduced Voltage Autotransformer Starter Wye-elta Starter Part Winding Starter Pump Panels Simplex Pump Panel Simplex Pump Panel (NEA Size) uplex Pump Panel edium - Series A (-E) 9-146(-E) 9-190(-E) 9-205(-E) 9-265(-E) 9-305(-E) 9-370(-E) E E E E E E ontrol Transformer ode Primary Secondary XA XB X X XE XF XG For additional ontrol Transformer odes, refer to odification pages in this section. This illustration is for reference only. Turn to the appropriate page to determine specific catalog number. ➊ () & (E) suffix designates contactors with coils 4

5 EE TB20 G 3 Overload Relay Short-ircuit / isconnect EP7 Second Generation - Solid State A7-9 thru A E 1... EP7 O/L Relay, 3Ø, lass 10, man. reset E... EP7S O/L Relay, 1Ø, (selectable) E... EP7 O/L Relay, 3Ø, (selectable) T.. urrent Transformers T7N - Bimetallic Thermal A7-9 thru A A- T7N O/L Relay, lass 10, manual or automatic reset...p T7N O/L Relay, lass 10, manual or automatic reset, separate mount Through-the-oor Operated ombo Thermal agnetic ircuit Breaker Fusible isconnect Non Fusible isconnect TB(H)15 15 Amp JF61 600V/30A JU61 600V/30A TB20 20 Amp JF62 600V/60A JU62 600V/60A TB25 25 Amp JF63 600V/100A JU63 600V/100A JF64 600V/200A JU64 600V/200A thru JF65 600V/400A JU65 600V/400A JF66 600V/600A TB Amp JF67 600V/800A Enclosure G General Purpose - Type 1 usttight - Type 12 W - Type 4 orrosion Resistant - Type 4X R Raintight - Type 3R E Explosion proof - Type 7 Enclosure over ontrol Non-Reversing 1 Pilot Light Only 2 Pilot Lights (2) Only 3 Start-Stop PB 4 On-Off PB 5 Hand-Auto S/S 6 Off-On S/S 7 Hand-Off-Auto S/S 9 Emergency Stop PB 0 None Reversing 2 Pilot Lights (2) Only 3 For-Stop-Rev PB 4 Up-Stop-own PB 5 Open-Stop-lose PB 6 For-Off-Rev S/S 7 Up-Off-lose S/S 8 Open-Off-lose S/S 0 None ulti-speed 2 Pilot Lights (2) Only 3 High-Stop-Low 4 Fast-Stop-Slow 5 High-Off-Low 6 Fast-Off-Slow S/S For additional over ontrol odes, refer to odifications page in this section. For complete listing of Option odes, refer to odification pages in this section. Options Starters & Enclosed Products Blank None Blank None Blank None * TBH represents high interrupt capacity breaker 5

6 General nformation Enclosure Ratings NEA / UL Enclosure Type efinitions NEA / UL Type (P Equivalent ➊) Starters & Enclosed Products For a degree of protection against: 1 (P23) ndoor Use Outdoor Use ndoor or Outdoor Use 12 (P55/65) 13 (P65) ncidental contact with enclosed equipment Falling dirt Rust irculating dust, lint, fibers and flyings Windblown dust Falling liquids and light splashing Rain (limited water allowed inside) Rain (no water allowed inside) Snow and sleet Hosedown and splashing water Occasional prolonged submersion Oil or coolant spraying or splashing 3R 3 (P64) 4 (P66) 4X (P66) 6P 6 (P67) orrosive agents Occasional temporary submersion Explosion-Proof Enclosure Type efinitions NEA lassifications - arked with Rated lass, ivision, and Group NEA 7 For use in indoor locations classified as lass, Groups A, B, or, as defined in the National Electrical ode NEA 8 For use in indoor or outdoor locations classified as lass, Groups A, B, or, as defined in the National Electrical ode - oil immersed NEA 9 For use in indoor locations classified as lass, Groups E, F or G, as defined in the National Electrical ode Summary of NE lasses and Group Examples Group lass (Potentially explosive gas or vapor) Group lass (Potentially explosive dusts) A Acetylene E etallic usts (all metals) B Hydrogen, Ethylene Oxide, Propylene Oxide F arbonaceous usts (coal, asphalt, etc.) Ether, Hydrogen Sulfide, Hydrazine, Nitroethane G Nonconductive usts (grain, drugs, pesticides, plastics, dyes, etc.) ethane, Acetone, Benzene, Gasoline, Naptha Summary of NE ivisions ivision 1 Potentially explosive substance present under normal operating conditions ivision 2 Potentially explosive substance present under abnormal operating conditions ➊ P Equivalents are only approximate. t is the responsibility of the user to verify the enclosure rating necessary for the given application. 6

7 General nformation Enclosure Ratings P Ratings efinitions Starters & Enclosed Products 7

8 Orange Express Starters & Enclosed Products A program designed to meet the demand for shipment of enclosed contactors, starters and Type E Self-Protected anual otor ontrollers in 3 days or less, from the time we enter your order until it is ready for shipment; GUARANTEE. Sprecher + Schuh has shipped stock components for years while the demands on our ustom ontrol Panel Shop business has steadily increased. Our panel facilities accommodate customer demand for quick turn around on standard enclosed contactors, manual motor starters, magnetic motor starters and combination starters. ore stock, more manpower and streamlined logistics are all combined to make it possible for Sprecher + Schuh to guarantee three day shipment for a variety of enclosed products. heck out the details of Orange Express; we are confident you won t be disappointed! Getting started Orange Express orders received by ustomer Service by noon on day one will ship by the end of day three. Orange Express orders must be complete with all details before the three day clock can be started. Orange Express orders must be clearly identified as an Orange Express order on the purchase order. Orange Express orders may be shipped standard freight or express. Express delivery must be clearly marked and will be pre-paid and charged. Orange Express orders are limited to the enclosed products detailed and marked with the OE logo in this catalog. Orange Express orders may include up to five items; that s five of the same item or five different line items. Orange Express orders must utilize established Sprecher + Schuh standard wiring diagrams. Orange Express orders cannot be combined with any other specialty programs. 8

9 Look for the Orange Express cons The OE icon is scattered throughout the catalog, indicating which products are available in the program. Orange Express includes the following products: KWKstarters FVNR A7 ontactors Type 1 and 12 enclosed FVR A7 ontactors Type 1 and 12 enclosed FVNR AT7 agnetic Starters Type 1, 12 and non-metallic 4X enclosed FVR AUT7 agnetic Starters Type 1, 12 and non-metallic 4X enclosed FVNR BT7 agnetic Starters Type 1, 12 and non-metallic 4X enclosed FVR BUT7 agnetic Starters Type 1, 12 and non-metallic 4X enclosed. FVNR ATN7 NEA Size 00, 0, 1 and 2 agnetic Starters Type 1, 12 and non-metallic 4X enclosed ombo AT7 & ATN7 B FVNR agnetic Starters - Type 1, 12 and non-metallic 4X enclosed ombo AT7 Fusible FVNR agnetic Starters - Type 1, 12 and non-metallic 4X enclosed ombo AT7 Non-Fusible FVNR agnetic Starters - Type 1, 12 and non-metallic 4X enclosed KTA7 Type E Self-Protected anual otor ontroller Type P65, 12, 4 and non-metallic 4X enclosed X7 Type E KTA7 Self-Protected ombination FVNR ontroller Type 4/12 enclosed This item is available in the ORANGE E PRESS 3-day shipping program All contactors and starters listed are with A coil only Options - factory installed modifications include: -- Start Stop Pushbutton -- Hand Off Auto Selector Switch -- Forward Stop Reverse Pushbutton for FVR starters/ contactors -- Forward Off Reverse Selector Switch for FVR starters/ contactors -- Pilot Lights (Two aximum) -- Additional interlocks -- Surge Suppressor -- ontrol Power Transformer (with primary and secondary fusing as required) Starters & Enclosed Products Our Guarantee Orange Express orders not shipped by day three, for some unforeseen reason, will be shipped via premium freight at our expense; that s Sprecher + Schuh s guarantee of quality service and performance. 9

10 ustom ontrol Panels esigned and built to meet Your needs ustom ontrol Panels SO9001, UL508 & UL1203 (NNNY) ATEX ertified Panel Shop Need ustom ontrol Panels? You Got t Sprecher + Schuh is your go to builder for custom motor control panels. Our panel shops are UL508 and SA approved. This means our knowledgeable team can design your panel for custom applications to meet UL/SA, ATEX, UL1203, and E standards. Our engineering and custom quotes staff work with the customer one-on-one in designing a motor control panel that best fits the customer s needs. No job is too small or too big for our staff to take on. We continuously strive to develop innovative, new products and improve existing designs. We constantly strive to maintain a superior level of service including our SO 9001 ertification. What an We Build For You? Regardless of your industry or custom control panel needs, we at Sprecher + Schuh have the engineering experience and manufacturing facilities to design and build your panels. Whether your need is to design an OE panel that will be repeated, or a one-of-a-kind, we have an experienced engineering and quality control team dedicated to providing the best solution to your custom control panels. Our manufacturing facilities are staffed with experienced wiring and installation technicians, ensuring your custom panel meets safety and performance criteria. Through this commitment to service, and never-ending attention to detail, we continue to be the first and last words in motor protection. Our large panel shop is designed to accommodate our customers needs. We stock not only Sprecher + Schuh components but also B and popular enclosures in a variety of sizes and types (metallic, non-metallic, and explosion-proof). This means we can design, assemble, wire, and quickly ship a variety of custom panels. 10

11 ustom Built Panels ustom built to your specifications! ulti-otor Starter Panels ombination & Non-ombination otor Starters Reduced Voltage Starters Softstarter Panels (see Section ) ulti-plex Pump Panels oor-in-oor Panels Explosion-Proof Starters UL508/SA Labeled ustom Panels ATEX Explosion Proof Panels Labeled Service Entrance Rated Panels and many more! ustom ontrol Panels For your contact customquotes@sprecherschuh.com 11

12 FS Fractional anual Starters Fractional anual Starters Easy, simple starting of otors up to 1 HP Fractional anual Starter FS with Neon Pilot light Optional Locking Attachment Sprecher + Schuh Fractional anual Starters (FS) consist of a snap switch combined with a thermal overload device operating on the solder-ratchet principle. To reset the overload mechanism, the switch lever is moved to the OFF position. The motor can be restarted by simply pushing the switch lever to the ON position. The switch is designed to prevent being held closed under a sustained motor overload. Ratings (HP) Type V 277V Poles General Purpose Surface ounting A A ➋ atalog Number Price Toggle Switch Only Pole FS-TAX Pole FS-TAX5 129 Toggle Switch with Neon Pilot Light (115 or 230V) Pole FS-TAX Pole FS-TAX Accessory atalog Number Price Locking Attachment For locking toggle switch in ON or OFF position. FS-N1 18 Selecting Heater Elements ➌ The Full Load Amps listed in the table can be used for heater element selection. The rating of the relay in amperes at 40º is 115% of the Full Load Amps (FLA) listed for the catalog number. Refer to the motor nameplate for the full load current, the service factor, and/or the motor classification by application and temperature rise. Use this motor nameplate information, the application rules and the FLA listed in the table to determine the Heater Element catalog number for motors rated for ontinuous uty. 1. For the Same Temperature at the ontroller and otor : Select the Heater Element with the listed FLA nearest the full load value shown on the motor nameplate. 2. For Higher Temperature at the ontroller than at the otor : f the full load current value shown on the motor nameplate is between the listed FLAs, select the Heater Element with the next higher value. 3. For a Lower Temperature at the ontroller than at the otor : f the full load current value shown on the motor nameplate is between the listed FLAs, select the Heater Element with the next lower value. 4. All other motors rated for continuous duty (includes motors with marked service factor 1.0): Select the Heater Element one rating smaller than determined by rules in 1, 2 and 3. Ordering nstructions Order FS atalog Number Order Required FS Heater Element(s) ➊ Order Optional FS Locking Attachment ➊ One heater is required for 1-pole or 2-pole applications. See schematic on next page. ➋ Two-pole selections are applicable for 3/4 HP at V. ➌ Rule 2 and 3 temperature difference not to exceed more than 10º (18ºF). Easy to Order FS Starters are easy to order. Simply choose a 1-Pole or 2-Pole with or without the Neon pilot light and then order the required Heater Element. You re done! Typical Applications Starting and overload protection of small 1-phase V A/ or 277 VA motors used on the following applications: Unit heaters Fans Stokers Pumps Refrigeration compressors Heater Element (Required) ➊ Full Load Amps atalog Number 0.17 FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P FS-P39 Price iscount Schedule B8

13 Fractional anual Starters Technical nformation/imensions Technical nformation Eutectic Operation Thermal overload devices using the eutectic alloy method are spring loaded in the normal, or reset, position. When the heater is cold, the solder is solid and holding the spring loaded rachet. When FLA is passed through the heater, and if excess current flows, then the solder will melt and allow the rachet mechanism to turn. This result trips the device. The device is reset by turning the switch to the OFF position and allowing it to cool. Standards ompliance UL 508 EN SA 22.2, No. 14 ertifications UL Listed - Enclosed Products (File No. E14841; Guide No. NLRV) SA ertified (File No. LR 1234) American Burea of Shipping (ABS) E marked 1-POLE 2-POLE Trip Time lass 20 Reset Time: The actual time to reset will vary based on the ambient temperature surrounding the overload. Under most conditions, it will take from approximately 90 seconds up to 5 minutes for the solder to solidify enough for the overload to be reset. Until this happens, the overload will not be able to be reset by pressing on the reset button. The ratchet assembly inside the overload block will spin freely until the solder has solidfied. FS Fractional anual Starters imensions TE - urrent haracteristics at 40º FS Type 1 General Purpose Surface ounting epth with Lever Operator 2-31/32 (75.4) Time - Seconds Percent of Rated urrent NOTE: Trip will occur at 115% of FLA iscount Schedule B8 13

14 KWKstarters KWKstarters Preassembled or build from stock Easy, fast, economical enclosed starters for applications up to 30HP ost KWKstarters are equipped with Thermal Overload protection as standard Sprecher + Schuh offers a broad selection of pre-assembled or build-fromstock starters housed in a high impact, non-metallic, cul Approved, Type 1, 12, 4, 4X enclosure. Built for convenience, space savings and economy, KWKstarters are efficiently designed to use stock A7 contactors and EP7 or T7N overloads usually stocked by distributors. ontactor and overload are either pre-wired and pre-mounted onto the enclosure s built-in N-rail or may be ordered as separate components. Ample knockouts and open terminals guarantee quick, no fuss wiring. Sized for most industrial applications KWKstarters control motors up to 460V in two sizes of enclosures, measuring only 208 x 98mm (7.4 x 3.9 ) or 250 x 125mm (9.85 x 4.93 ) for our larger sizes. This covers over 85% of industrial motor control applications in a very compact package that can be mounted adjacent to or directly on equipment. Thermal overload protection KWKstarters, sized 9 to 23 amps, are equipped with Sprecher + Schuh s T7N bimetallic thermal overload relay as standard. The consistent high quality of our thermal overload relays is ensured by a complex current calibration procedure performed after each unit is at full operating temperature. KWKstarters are also available with our advanced EP7 Solid State Overload Relay (select appropriate overload relay code for this option) Solid state overload options KWKstarters, sizes 9 to 23 amps, can also be supplied with Sprecher + Schuh s EP7 solid state overload relay. The EP7 Overload is standard on larger (sizes 30 to 43 amps) and all reversing KWKstarters. The EP7 solid state overload relays measure motor current directly through integrated current transformers and on board electronics. The electronics provide increased accuracy and numerous other advantages over electromechanical relays. Learn more about Sprecher + Schuh overload relays in Section B of this catalog. Build it yourself KWKstarters may be assembled from stock components. Just grab a A7 contactor and overload of your choice and snap them into the enclosure. inimal wiring is required and assembly can be completed in minutes. Start-Stop or Reset only Hand-Off-Auto with Pilot Light Emergency Stop ulti-function Forward-Stop-Reverse options ombination Kwikstarters 14

15 X7 KWKstarters Type E/F ombination otor ontrollers KTA7 can be applied in combination with a A7 contactor for remote control and an enclosure with matching environmentally approved thru-thedoor handle disconnect mechanism to meet all requirements for a onstruction Type E or F ombination Starter. This selection of individual ombination starters are smaller and are less expensive than lassic onstruction Type A (Fusible), or Type (Thermal-magnetic olded ase ircuit Breaker), as offered in the following pages. KWKstarters Sprecher + Schuh has developed a KWKStarter version of the ombination otor ontroller which can be easily field assembled or can be purchased as a factory assembly. For details and catalog number selection on these economical combination starter alternatives turn to page F98. Why Type E/F? NE defines that the short-circuit protection of a single motor branch circuit shall be provided by a set of fuses or a thermalmagnetic molded case circuit breaker. Alternatively NE also permits the use of a Self-protected ombination otor ontroller can be used to not only provide short-circuit protection for a single motor branch circuit but also provide a means of disconnect and overload protection. Self-protected ombination motor controllers like KTA7 can be combined with A7, providing a coil for cover control or remote operation. This results in a onstruction Type E or Type F (based on selection depending on published UL ratings) ombination starter per UL508. For details of UL, NE and SA application standards and rules please see our online white paper, Applying KT7 otor ontrollers. See page F98 for Type E/F X7KWKstarters 15

16 KWKstarters Series AK7 & BK7 - A oils KWKstarters with T7N or EP7 Overload Relays; ➊➏ over ontrol/ Enclosure (KS7-0S1/0S4) Single Ø aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 imension ode KWKstarters 115V 230V 200V 230V 460V 575V NO N atalog Number Price ➌ KWKstarter with Start & Raised Stop ❹➎ 1/2 1 1/2 ~ ~ ~ ~ BK P2 1 ➋ 0 ~ ~ /2 AK P2 292 Q1 1/2 2 ~ ~ ~ ~ BK P2 1 ➋ 0 ~ ~ /2 10 AK P2 327 Q1 1 3 ~ ~ ~ ~ BK P2 1 ➋ 0 ~ ~ AK P2 351 Q1 2 3 ~ ~ ~ ~ BK P2 1 ➋ 0 ~ ~ 5 7 1/ AK P2 378 Q1 KWKstarter with Reset 1/2 1 1/2 ~ ~ ~ ~ BK P Q1 ~ ~ /2 AK P0 1/2 2 ~ ~ ~ ~ BK P0 1 0 ~ ~ /2 10 AK P0 1 3 ~ ~ ~ ~ BK P0 1 0 ~ ~ AK P0 2 3 ~ ~ ~ ~ BK P0 1 0 ~ ~ 5 7 1/ AK P0 303 Q1 327 Q1 353 Q1 oil odes ➎ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK7 24Z 24V 24V Separate Separate V 120V ommon Separate 208 ~ 208V ~ ommon 220W 200V-220V 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon ontrol ircuit Note ommon: oils are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils are assumed to be from a separate source and will not be connected to the line source per the table. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay See this page See page 30 mportant Note: KWKstarters are only designed to accommodate T7N Thermal Overload Relays or EP7 Solid State Overload Relays. Select O/L Relay ode from page 30. ➊ KWKstarters are designed for three-wire control circuits. Two-wire (maintain) control can be accomplished by adding pushbutton latch KS7-PLA. ➋ A special design NO auxiliary contact (at.# KS7-PK) is used as the holding circuit interlock, as well as, the START button interface. t is not available for other use. ➌ Refer to page 33 for dimensional information. ➍ STOP button also functions as RESET button. Plastic Bezel is standard. ➎ Other voltages available, see Section A. ➏ Use T7N or EP7-E/EP7-EE overload. 16 iscount Schedule B7

17 KWKstarters Series AK7 & BK7 - Electronic oils KWKstarters with T7N or EP7 Overload Relays; ➊➍➎➏ over ontrol/ Enclosure (KS7-0S1/0S4) Single Ø aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 imension ode 115V 230V 200V 230V 460V 575V NO N atalog Number Price ➌ KWKstarter with Start & Raised Stop ❹➎ 1/2 1 1/2 ~ ~ ~ ~ BK7-9E- - -P2 1 ➋ Q1 ~ ~ /2 AK7-9E- - -P2 1/2 2 ~ ~ ~ ~ BK7-12E- - -P2 1 ➋ Q1 ~ ~ /2 10 AK7-12E- - -P2 1 3 ~ ~ ~ ~ BK7-16E- - -P2 1 ➋ Q1 ~ ~ AK7-16E- - -P2 KWKstarters 2 3 ~ ~ ~ ~ BK7-23E- - -P2 1 ➋ 0 ~ ~ 5 7 1/ AK7-23E- - -P2 473 Q1 KWKstarter with Reset 1/2 1 1/2 ~ ~ ~ ~ BK7-9E- - -P0 1 0 ~ ~ /2 AK7-9E- - -P0 1/2 2 ~ ~ ~ ~ BK7-12E- - -P0 1 0 ~ ~ /2 10 AK7-12E- - -P0 1 3 ~ ~ ~ ~ BK7-16E- - -P0 1 0 ~ ~ AK7-16E- - -P0 2 3 ~ ~ ~ ~ BK7-23E- - -P0 1 0 ~ ~ 5 7 1/ AK7-23E- - -P0 342 Q1 387 Q1 417 Q1 449 Q1 oil odes ➎ oil odes 12E 24E Voltage 12V 24V Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay See this page See page 30 mportant Note: KWKstarters are only designed to accommodate T7N Thermal Overload Relays or EP7 Solid State Overload Relays. Select O/L Relay ode from page 30. ➊ KWKstarters are designed for three-wire control circuits. Two-wire (maintain) control can be accomplished by adding pushbutton latch KS7-PLA. ➋ A special design NO auxiliary contact (at.# KS7-PK) is used as the holding circuit interlock, as well as, the START button interface. t is not available for other use. ➌ Refer to page 33 for dimensional information. ➍ STOP button also functions as RESET button. Plastic Bezel is standard. ➎ A7-9E 23E with electronic coils are not interchangeable with non-electronic or A coils ➏ Use T7N or EP7-E/EP7-EE overload. iscount Schedule B7 17

18 KWKstarters Series AK7 & BK7 - A oils KWKstarters with EP7 Overload Relays ➊ Enclosure (KS7-2S4) Single Ø aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 imension ode KWKstarters 115V 230V 200V 230V 460V 575V NO N atalog Number Price ➌ KWKstarters with A oil 2 5 ~ ~ ~ ~ BK ET-P 1 0 ~ ~ 7-1/ AK P 3 5 ~ ~ ~ ~ BK ET-P 1 0 ~ ~ AK P 3 7-1/2 ~ ~ ~ ~ BK ET-P 1 0 ~ ~ AK P Replace with one of the following Overload Relays For use with KWKstarter... Amp Range Overload Relay ode ( ) atalog No. (of Overload Relay used) Price Adder 3-Phase / anual Reset / lass EP7-E EP7-E1 +0 AK E EP7-E1E F EP7-E1F +0 3-Phase / Auto or anual Reset / lass 10, 15, 20, E EP7-EE E EP7-EE +21 AK EE EP7-EEE EF EP7-EEF +21 Pilot evice Options (includes reset) ➋➎ Replace in catalog number with Price Adder Pushbutton escription START-STOP ulti-function (shown) 3U Standard -O ulti-function 4U Standard OFF-ON 2-Position Selector switch 6 Standard Pilot Light Red (LE) with START-STOP ulti-function 1R3U +50 Pilot Light Red (LE) with -0 ulti-function 1R4U +50 Optional A7 odifications (Factory Assembled) escription Add to end of catalog number Price Adder Electronic nterface -JE +94 Surge Suppressor R Surge Suppressor Varistor -V +54 Additional N ontact -L Additional NO ontact -L oil odes (Q) ➍➏ 447 Q2 491 Q2 581 Q2 A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK7 24Z 24V 24V Separate Separate V 120V ommon Separate 208 ~ 208V ~ ommon 220W 200V-220V 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Replace ( ) with Pilot evice Option ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Pilot lights are 240 VA maximum. See this page only ➊ Use EP7-E/EP7-EE overloads only. Single-phase applications utilize EP7S-EET only. ➋ Plastic Bezel is standard. Pilot evice options include 7-BX_ Base ounted contact blocks. See page H69 for more information. ➌ Refer to page 31 for wiring diagram and 34 for dimensional information. ➍ Other voltages available, see Section A. ➎ One and only one Pilot evice option must be selected. f Pilot Light option is selected then coil voltage must be 24V, 120V or 240V A only. ➏ PT not possible with KS7-2S4 (Q2) enclosure. 18 iscount Schedule B7

19 KWKstarters Series AK7 & BK7 - Electronic oils KWKstarters with EP7 Overload Relays ➊ Enclosure (KS7-2S4) Single Ø aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 imension ode 115V 230V 200V 230V 460V 575V NO N atalog Number Price ➌ KWKstarters with Electronic oil ➍ 2 5 ~ ~ ~ ~ BK7-30E- -ET-P Q2 ~ ~ 7-1/ AK7-30E- - -P 3 5 ~ ~ ~ ~ BK7-37E- -ET-P Q2 ~ ~ AK7-37E- - -P KWKstarters 3 7-1/2 ~ ~ ~ ~ BK7-43E- -ET-P 1 0 ~ ~ AK7-43E- - -P 743 Q2 Replace with one of the following Overload Relays For use with KWKstarter... Amp Range Overload Relay ode ( ) atalog No. (of Overload Relay used) Price Adder 3-Phase / anual Reset / lass EP7-E EP7-E1 +0 AK E EP7-E1E F EP7-E1F +0 3-Phase / Auto or anual Reset / lass 10, 15, 20, E EP7-EE E EP7-EE +21 AK EE EP7-EEE EF EP7-EEF +21 Pilot evice Options (includes reset) ➋➎ Replace in catalog number with Price Adder Pushbutton escription START-STOP ulti-function (shown) 3U Standard -O ulti-function 4U Standard OFF-ON 2-Position Selector switch 6 Standard Pilot Light Red (LE) with START-STOP ultifunction 1R3U +50 Pilot Light Red (LE) with -0 ulti-function 1R4U +50 Optional A7 odifications (Factory Assembled) escription Add to end of catalog number Price Adder Electronic nterface -JE +94 Surge Suppressor R Surge Suppressor Varistor -V +54 Additional N ontact -L Additional NO ontact -L oil odes ➍➏.. oil ode Voltage Range V 12E 12V 24E 24V 36E 36-48V 48E 48-72V 110E V 220E V Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Replace ( ) with Pilot evice Option See this page only ➊ Use EP7-E/EP7-EE overloads only. Single-phase applications utilize EP7S-EET only. ➋ Plastic Bezel is standard. Pilot evice options include 7-BX_ Base ounted contact blocks. See page H69 for more information. ➌ Refer to page 31 for wiring diagram and 34 for dimensional information. ➍ A7-9E 55E with electronic coils are not interchangeable with non-electronic or A coils. ➎ One and only one Pilot evice option must be selected. ➏ PT not possible with KS7-2S4 (Q2) enclosure. iscount Schedule B7 19

20 KWKstarters Series AK7 & BK7 - A or with H-O-A KWKstarters KWKstarters with T7N or EP7 Overload Relays with H-O-A and Light ➊➋➌➎➏ over ontrol/ Enclosure Single Ø aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 115V 230V 200V 230V 460V 575V NO N atalog Number Price ➍ KWKstarter with Reset and H-O-A Selector Switch and Light with A oil 1/2 1 1/2 ~ ~ ~ ~ BK P0+1R7 1 0 ~ ~ /2 AK P0+1R7 1/2 2 ~ ~ ~ ~ BK P0+1R7 1 0 ~ ~ /2 10 AK P0+1R7 1 3 ~ ~ ~ ~ BK P0+1R7 1 0 ~ ~ AK P0+1R7 imension ode 654 Q1 721 Q1 765 Q1 2 3 ~ ~ ~ ~ BK P0+1R Q1 ~ ~ 5 7 1/ AK P0+1R7 KWKstarter with Reset and H-O-A Selector Switch and Light with Electronic oil ➐ 1/2 1 1/2 ~ ~ ~ ~ BK7-9E- - -P0+1R7 1 0 ~ ~ /2 AK7-9E- - -P0+1R7 1/2 2 ~ ~ ~ ~ BK7-12E- - -P0+1R7 1 0 ~ ~ /2 10 AK7-12E- - -P0+1R7 1 3 ~ ~ ~ ~ BK7-16E- - -P0+1R7 1 0 ~ ~ AK7-16E- - -P0+1R7 2 3 ~ ~ ~ ~ BK7-23E- - -P0+1R7 1 0 ~ ~ 5 7 1/ AK7-23E- - -P0+1R7 803 Q1 890 Q1 945 Q Q1 oil odes ➐ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK7 24Z 24V 24V Separate Separate V 120V ommon Separate 208 ~ 208V ~ ommon 220W 200V-220V 208V-240V ommon ommon V 240V ommon ommon.. oil ode Voltage Range V 12E 12V 24E 24V ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Line Voltage not listed: (i.e.: 480 and 575 VA) require a separate control source (i.e.: 120 VA). 7 pilot devices are rated 300 VA maximum. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay See this page See page 30 mportant Note: KWKstarters are only designed to accommodate T7N Thermal Overload Relays or EP7 Solid State Overload Relays. Select O/L Relay ode from page 30. ➊ This is a factory assembly. The KS7-0S1 (Q1) enclosure does not include knock-outs for field assembly of this starter. ➋ Uses 7-P4N_ Red onolithic Run pilot light with LE bulb. Pilot light voltage to match coil voltage for 24, 120, 240 VA control. Red Run Light can be changed for Green. hange +1R7 to +1G7. For example, AK P0+1R7 becomes AK P0+1G7. ➌ Uses 7-S32x20 onolothic 3-position selector switch for maintain control, HAN-OFF- AUTO function with legend plate. ➍ Refer to page 32 for wiring and dimensional information. This is a clam-shell enclosure design with wires to cover controls. ➎ Uses T7N or EP7-E/EP7-EE overload. ➏ One NO auxilliary for customer use. There is no room for additional auxilliaries. ➐ A7-9E 23E with electronic coils are not interchangeable with non-electronic or A coils. 20 iscount Schedule B7

21 KWKstarters Series AK7 & BK7 - A with E-Stop KWKstarters with T7N or EP7 Overload Relays with -O ultifunction and E-Stop ➊➋➌➎➏ over ontrol/ Enclosure Single Ø aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 imension ode 115V 230V 200V 230V 460V 575V NO N atalog Number Price ➍ KWKstarter with Reset, ultifunction -O Pushbutton and E-Stop with A oil 1/2 1 1/2 ~ ~ ~ ~ BK P0+4U ~ ~ /2 AK P0+4U-9 1/2 2 ~ ~ ~ ~ BK P0+4U ~ ~ /2 10 AK P0+4U ~ ~ ~ ~ BK P0+4U ~ ~ AK P0+4U Q1 438 Q1 462 Q1 KWKstarters 2 3 ~ ~ ~ ~ BK P0+4U ~ ~ 5 7 1/ AK P0+4U Q1 oil odes A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK7 24Z 24V 24V Separate Separate V 120V ommon Separate 208 ~ 208V ~ ommon 220W 200V-220V 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Line Voltage not listed: (i.e.: 480 and 575 VA) require a separate control source (i.e.: 120 VA). This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay See this page See page 30 mportant Note: KWKstarters are only designed to accommodate T7N Thermal Overload Relays or EP7 Solid State Overload Relays. Select O/L Relay ode from page 30. ➊ This is a factory assembly. The KS7-0S1 (Q1) enclosure does not include knock-outs for field assembly of this starter. ➋ Uses 7P-U2EFFEPX11 Two-Position ultifunction push button with legend /O. ➌ Uses 7P-T44PX01 Emergency Stop Push Button. ➍ Refer to page 33 for wiring and dimensional information. This is a clam-shell enclosure design with wires to cover controls. ➎ Uses T7N or EP7-E/EP7-EE overload. ➏ There is no room for additional auxilliaries. iscount Schedule B7 21

22 KWKstarters / Reversing Series AUK A oils Three Phase Reversing KWKstarters with EP7 Overload Relays ➊ Enclosure (KS7-0S4R) aximum Horsepower Three Ø Auxiliary ontacts per ontactor ➐ cul Approved- Type 1/12/4/4X P66 imension ode KWKstarters 200V 230V 460V 575V NO N atalog Number Price ➌ FVR 3-Phase with A oil /2 1 1 AUK P 377 Q / AUK P 412 Q AUK P 437 Q / AUK P 463 Q3 oil odes (Q) ➍➏ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK7 24Z 24V 24V Separate Separate V 120V ommon Separate 208 ~ 208V ~ ommon 220W 200V-220V 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon Pilot evice Options (includes reset) ➋➎ Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Replace ( ) with Pilot evice Option Replace in catalog number with See this page only Price Adder Pushbutton escription FOR-STOP-REV ulti-function (shown) 3U Standard UP-STOP-OWN ulti-function 4U Standard OPEN-STOP-LOSE ulti-function 5U Standard FOR-STOP-REV 3-Position Selector switch 6 Standard UP-OFF-OWN 3-Position Selector switch 7 Standard OPEN-OFF-LOSE 3-Position Selector switch 8 Standard Overload Alarm Pilot Light 1Y Standard 7-N8 22mm Hole Plug 0 Standard Optional A7 odifications (Factory Assembled) escription (supplied on each contactor) Add to end of catalog number Price Adder Electronic nterface -2JE +188 Surge Suppressor R Surge Suppressor Varistor -2V +108 ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Pilot lights are 240 VA maximum. Replace with one of the following Overload Relays For use with KWKstarter... AUK AUK7-9E...23E AUK AUK7-9E...23E Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) Price Adder 3-Phase / anual Reset / lass AB EP7-E1AB Standard BB EP7-E1BB Standard B EP7-E1B Standard B EP7-E1B Standard EB EP7-E1EB Standard 3-Phase / Auto or anual Reset / lass 10, 15, 20, EAB EP7-EEAB EBB EP7-EEBB EB EP7-EEB EB EP7-EEB EEB EP7-EEEB +17 ➊ Use EP7-E/EP7-EE overloads only. ➋ Plastic Bezel is standard. Pilot evice options include 7-BX_ Base ounted contact blocks. See page H69 for more information. ➌ Refer to page 32 for wiring diagram and 34 for dimensional information. ➍ Other voltages available, see Section A. ➎ One Pilot evice option must be selected. Blanks are not available. f Pilot Light option is selected then coil voltage must be 24V, 120V or 240V A only. ➏ PT not possible with KS7-0S4R (Q3) enclosure. ➐ One N.. auxiliary contact is used for electrical interlocking. On AUK7 reversing starters, the N.. contact comes from the echanical/electrical nterlock unit (at# 7-02). 22 iscount Schedule B7

23 KWKstarters / Reversing Series AUK Electronic oils Three Phase Reversing KWKstarters with EP7 Overload Relays ➊ Enclosure (KS7-0S4R) aximum Horsepower Three Ø Auxiliary ontacts per ontactor ➐ cul Approved- Type 1/12/4/4X P66 imension ode 200V 230V 460V 575V NO N atalog Number Price ➌ FVR 3-Phase with Electronic oil /2 1 1 AUK7-9E- - -P 451 Q / AUK7-12E- - -P 497 Q AUK7-16E- - -P 527 Q3 KWKstarters 5 7 1/ AUK7-23E- - -P 559 Q3 oil odes ➍➏.. oil ode Voltage Range V 12E 12V 24E 24V 36E 36-48V 48E 48-72V 110E V 220E V Pilot evice Options (includes reset) ➋➎ Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Replace ( ) with Pilot evice Option Replace in catalog number with See this page only Price Adder Pushbutton escription FOR-STOP-REV ulti-function (shown) 3U Standard UP-STOP-OWN ulti-function 4U Standard OPEN-STOP-LOSE ulti-function 5U Standard FOR-STOP-REV 3-Position Selector switch 6 Standard UP-OFF-OWN 3-Position Selector switch 7 Standard OPEN-OFF-LOSE 3-Position Selector switch 8 Standard Overload Alarm Pilot Light 1Y Standard 7-N8 22mm Hole Plug 0 Standard Optional A7 odifications (Factory Assembled) escription (supplied on each contactor) Add to end of catalog number Price Adder Electronic nterface -2JE +188 Surge Suppressor R Surge Suppressor Varistor -2V +108 Replace with one of the following Overload Relays For use with KWKstarter... AUK AUK7-9E...23E AUK AUK7-9E...23E Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) Price Adder 3-Phase / anual Reset / lass AB EP7-E1AB Standard BB EP7-E1BB Standard B EP7-E1B Standard B EP7-E1B Standard EB EP7-E1EB Standard 3-Phase / Auto or anual Reset / lass 10, 15, 20, EAB EP7-EEAB EBB EP7-EEBB EB EP7-EEB EB EP7-EEB EEB EP7-EEEB +17 ➊ Use EP7-E/EP7-EE overloads only. ➋ Plastic Bezel is standard. Pilot evice options include 7-BX_ Base ounted contact blocks. See page H69 for more information. ➌ Refer to page 32 for wiring diagram and 34 for dimensional information. ➍ A7-9E 55E with electronic coils are not interchangeable with non-electronic or A coils. ➎ One Pilot evice option must be selected. Blanks are not available. f Pilot Light option is selected then coil voltage must be 24V only. ➏ PT not possible with KS7-0S4R (Q3) enclosure. ➐ One N.. auxiliary contact is used for electrical interlocking. On AUK7 reversing starters, the N.. contact comes from the echanical/electrical nterlock unit (at# 7-02). iscount Schedule B7 23

24 NEA KWKstarters Series AKN7 & BKN7 - A and Electronic oils KWKstarters NEA KWKstarters with T7N or EP7 Overload Relays ➊➏ over ontrol/ Enclosure (KS7-0S1/0S4) oil odes ➎➐ NEA Size Single Ø aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 imension ode 115V 230V 200V 230V 460V 575V NO N atalog Number Price ➌ KWKstarter with Start & Raised Stop with A oil ❹➎ 1/3 1 ~ ~ ~ ~ BKN P2 1 ➋ 0 ~ ~ 1-1/2 1-1/2 2 2 AKN P2 515 Q1 1 2 ~ ~ ~ ~ BKN P2 1 ➋ 0 ~ ~ AKN P2 554 Q1 KWKstarter with Start & Raised Stop with Electronic oil ➐ 1/3 1 ~ ~ ~ ~ BKN7-12E- - -P2 1 ➋ 0 ~ ~ 1-1/2 1-1/2 2 2 AKN7-12E- - -P2 648 Q1 1 2 ~ ~ ~ ~ BKN7-16E- - -P2 1 ➋ 0 ~ ~ AKN7-16E- - -P2 695 Q1 KWKstarter with Reset with A oil 1/3 1 ~ ~ ~ ~ BKN P0 1 ➋ 0 ~ ~ 1-1/2 1-1/2 2 2 AKN P0 477 Q1 1 2 ~ ~ ~ ~ BKN P0 1 ➋ 0 ~ ~ AKN P0 515 Q1 KWKstarter with Reset with Electronic oil ➐ 1/3 1 ~ ~ ~ ~ BKN7-12E- - -P0 1 ➋ 0 ~ ~ 1-1/2 1-1/2 2 2 AKN7-12E- - -P0 610 Q1 1 2 ~ ~ ~ ~ BKN7-16E- - -P0 1 ➋ 0 ~ ~ AKN7-16E- - -P0 657 Q1 A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK7 24Z 24V 24V Separate Separate V 120V ommon Separate 208 ~ 208V ~ ommon 220W 200V-220V 208V-240V ommon ommon V 240V ommon ommon V 277V ommon ~ V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon.. oil ode Voltage Range V 12E 12V 24E 24V ontrol ircuit Note ommon: oils are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils are assumed to be from a separate source and will not be connected to the line source per the table. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay See this page See page 30 mportant Note: KWKstarters are only designed to accommodate T7N Thermal Overload Relays or EP7 Solid State Overload Relays. Select O/L Relay ode from page 30. ➊ KWKstarters are designed for three-wire control circuits. Two-wire (maintain) control can be accomplished by adding pushbutton latch KS7-PLA. ➋ A special design NO auxiliary contact (at.# KS7-PK) is used as the holding circuit interlock, as well as, the START button interface. t is not available for other use. ➌ Refer to page 33 for dimensional information. ➍ STOP button also functions as RESET button. Plastic Bezel is standard. ➎ Other voltages available, see Section A. ➏ Use T7N or EP7-E/EP7-EE overload. ➐ AN7-12E 16E with electronic coils are not interchangeable with non-electronic or A coils. 24 iscount Schedule B8

25 NEA KWKstarters Series AKN7 & BKN7 - A and Electronic oils NEA KWKstarters with T7N or EP7 Overload Relays with H-O-A and Light ➊➋➌➎➏ over ontrol/ Enclosure (KS7-0S1) NEA Size 00 0 Single Ø aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 115V 230V 200V 230V 460V 575V NO N atalog Number Price ➍ NEA KWKstarter with Reset and H-O-A Selector Switch and Light with A oil 1/3 1 ~ ~ ~ ~ BKN P0+1R7 1 ➏ 0 ~ ~ 1-1/2 1-1/2 2 2 AKN P0+1R7 1 2 ~ ~ ~ ~ BKN P0+1R7 1 ➏ 0 ~ ~ AKN P0+1R7 imension ode 636 Q1 674 Q1 KWKstarters NEA KWKstarter with Reset and H-O-A Selector Switch and Light with Electronic oil ➐ 00 1/3 1 ~ ~ ~ ~ BKN7-12E- - -P0+1R7 1 ➏ 0 ~ ~ 1-1/2 1-1/2 2 2 AKN7-12E- - -P0+1R7 796 Q ~ ~ ~ ~ BKN7-16E- - -P0+1R7 1 ➏ 0 ~ ~ AKN7-16E- - -P0+1R7 816 Q1 oil odes ➐ A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK7 24Z 24V 24V Separate Separate V 120V ommon Separate 208 ~ 208V ~ ommon 220W 200V-220V 208V-240V ommon ommon V 240V ommon ommon.. oil ode Voltage Range V 12E 12V 24E 24V ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Line Voltage not listed: (i.e.: 480 and 575 VA) require a separate control source (i.e.: 120 VA). 7 pilot devices are rated 300 VA maximum. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay See this page See page 30 mportant Note: KWKstarters are only designed to accommodate T7N Thermal Overload Relays or EP7 Solid State Overload Relays. Select O/L Relay ode from page 30. ➊ This is a factory assembly. The KS7-0S1 (Q1) enclosure does not include knock-outs for field assembly of this starter. ➋ Uses 7-P4N_ Red onolithic Run pilot light with LE bulb. Pilot light voltage to match coil voltage for 24, 120, 240 VA control. Red Run Light can be changed for Green. hange +1R7 to +1G7. For example, AKN P0+1R7 becomes AKN P0+1G7. ➌ Uses 7-S32x20 onolothic 3-position selector switch for maintain control, HAN-OFF- AUTO function with legend plate. ➍ Refer to page 32 for wiring and dimensional information. This is a clam-shell enclosure design with wires to cover controls. ➎ Uses T7N or EP7-E/EP7-EE overload. ➏ One NO auxilliary for customer use. There is no room for additional auxilliaries. ➐ AN7-12E 16E with electronic coils are not interchangeable with non-electronic or A coils. iscount Schedule B8 25

26 NEA KWKstarters Series AKN7 & BKN7 - A & Elec. 24V oils KWKstarters NEA KWKstarters with EP7 Overload Relays ➊ Enclosure (KS7-2S4) NEA Size Single Ø aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 imension ode 115V 230V 200V 230V 460V 575V NO N atalog Number Price ➌ NEA KWKstarters with A oil 2 3 ~ ~ ~ ~ BKN ET-P 1 0 ~ ~ 7-1/2 7-1/ AKN P 3 7-1/2 ~ ~ ~ ~ BKN ET-P 1 0 ~ ~ AKN P NEA KWKstarters with Electronic oil ➍ 3 5 ~ ~ ~ ~ BKN7-37E- -ET-P 1 0 ~ ~ AKN7-37E- - -P 3 7-1/2 ~ ~ ~ ~ BKN7-43E- -ET-P 1 0 ~ ~ AKN7-43E- - -P 773 Q2 915 Q2 965 Q Q2 oil odes (Q) ➍➎➐ Voltage A.. Voltage Range ontrol Source.. Range oil ode oil ode 50 Hz 60 Hz BK7 AK7 V 24Z 24V 24V Separate Separate 12E 12V Replace with one of the following Overload Relays For use with KWKstarter... AK AK Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) Price Adder 3-Phase / anual Reset / lass EP7-E EP7-E E EP7-E1E F EP7-E1F +0 3-Phase / Auto or anual Reset / lass 10, 15, 20, E EP7-EE E EP7-EE EE EP7-EEE EF EP7-EEF +21 ➊ Use EP7-E/EP7-EE overloads only. Single-phase applications utilize EP7S- EET only. ➋ Plastic Bezel is standard. Pilot evice options include 7-BX_ Base ounted contact blocks. See page H69 for more information. ➌ Refer to page 31 for wiring diagram and 34 for dimensional information. ➍ AN7-37E 43E with electronic coils are not interchangeable with non-electronic or A coils. A ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Pilot lights are 240 VA maximum V 120V ommon Separate 24E 24V 208 ~ 208V ~ ommon 36E 36-48V 220W 200V-220V 208V-240V ommon ommon 48E 48-72V V 240V ommon ommon 110E V V 277V ommon ~ 220E V V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon Pilot evice Options (includes reset) ➋➏ Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Replace ( ) with Pilot evice Option Replace in catalog number with See this page only Price Adder Pushbutton escription START-STOP ulti-function (shown) 3U Standard -O ulti-function 4U Standard OFF-ON 2-Position Selector switch 6 Standard Pilot Light Red (LE) with START-STOP ulti-function 1R3U +50 Pilot Light Red (LE) with -0 ulti-function 1R4U +50 Optional A7 odifications (Factory Assembled) escription Add to end of catalog number Price Adder Electronic nterface -JE +94 Surge Suppressor R Surge Suppressor Varistor -V +54 Additional N ontact -L Additional NO ontact -L ➎ Other voltages available, see Section A. ➏ One and only one Pilot evice option must be selected. f Pilot Light option is selected then coil voltage must be 24V A or, 120V or 240V A only. ➐ PT not possible with KS7-2S4 (Q2) enclosure. 26 iscount Schedule B8

27 NEA KWKstarters / Reversing Series AUKN7 - A & Elec. 24V oils Three Phase Reversing NEA KWKstarters with EP7 Overload Relays ➊ Enclosure (KS7-0S4R) NEA Size aximum Horsepower Three Ø Total Aux. ontacts nstalled cul Approved- Type 1/12/4/4X P66 imension ode 200V 230V 460V 575V NO N atalog Number Price ➌ 3-Phase FVR NEA KWKstarter with A oil /2 1-1/ AUKN P 1136 Q AUKN P 1205 Q3 3-Phase FVR NEA KWKstarter with Electronic 24V oil /2 1-1/ AUKN7-12E- - -P 1401 Q3 KWKstarters AUKN7-16E- - -P 1488 Q3 oil odes (Q) ➍➎➐ Voltage A.. Voltage Range ontrol Source.. Range oil ode oil ode 50 Hz 60 Hz BK7 AK7 V 24Z 24V 24V Separate Separate 12E 12V V 120V ommon Separate 24E 24V 208 ~ 208V ~ ommon 36E 36-48V 220W 200V-220V 208V-240V ommon ommon 48E 48-72V V 240V ommon ommon 110E V V 277V ommon ~ 220E V V-400V 440V ~ ommon V 480V ~ ommon V 600V ~ ommon Pilot evice Options (includes reset) ➋➏ Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Replace ( ) with Pilot evice Option Replace in catalog number with See this page only Price Adder Pushbutton escription FOR-STOP-REV ulti-function (shown) 3U Standard UP-STOP-OWN ulti-function 4U Standard OPEN-STOP-LOSE ulti-function 5U Standard FOR-STOP-REV 3-Position Selector switch 6 Standard UP-OFF-OWN 3-Position Selector switch 7 Standard OPEN-OFF-LOSE 3-Position Selector switch 8 Standard Overload Alarm Pilot Light 1Y Standard 7-N8 22mm Hole Plug 0 Standard Optional A7 odifications (Factory Assembled) escription (supplied on each contactor) Add to end of catalog number Price Adder Electronic nterface -2JE +188 Surge Suppressor R Surge Suppressor Varistor -2V +108 A ontrol ircuit Note ommon: oils and pilot devices in the control circuit are assumed to be common with the line voltage and will be connected to the line source (L1-L2) per the table. Separate: oils and pilot devices in the control circuit are assumed to be from a separate source and will not be connected to the line source per the table. Pilot lights are 240 VA maximum. Replace with one of the following Overload Relays For use with KWKstarter... AUKN AUKN7-12E..16E AUKN AUKN7-12E..16E Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) Price Adder 3-Phase / anual Reset / lass AB EP7-E1AB Standard BB EP7-E1BB Standard B EP7-E1B Standard B EP7-E1B Standard EB EP7-E1EB Standard 3-Phase / Auto or anual Reset / lass 10, 15, 20, EAB EP7-EEAB EBB EP7-EEBB EB EP7-EEB EB EP7-EEB EEB EP7-EEEB +17 ➊ Use EP7-E/EP7-EE overloads only. ➋ Plastic Bezel is standard. Pilot evice options include 7-BX_ Base ounted contact blocks. See page H69 for more information. ➌ Refer to page 32 for wiring diagram and 34 for dimensional information. ➍ AN7-12E 16E with electronic coils are not interchangeable with non-electronic or A coils. ➎ Other voltages available, see Section A. ➏ One Pilot evice option must be selected. Blanks are not available. f Pilot Light option is selected then Pilot Light must match oil Voltage 24V A or, 120V or 240V A only. ➐ PT not possible with KS7-0S4R (Q3) enclosure. ➑ One N.. auxiliary contact is used for electrical interlocking. On AUKN7 reversing starters, the N.. contact comes from the echanical/electrical nterlock unit (at# 7-02). iscount Schedule B8 27

28 KWKstarters Series AK7/BK /AUK KWKstarter 9 23A Enclosures with T7N or EP7 Overload Relays ➊➋ For Use With Environmental omponent escription ontactor Overload Approvals atalog Number Price Flush Green START / Extended Red STOP- echanical interface auxiliary contact (KS7-PK) included in enclosure. A T7N EP7-E1 EP7-EE cul Type 1/12/4/4x E P66 KS7-OS4 123 KWKstarters Blue RESET Only A T7N EP7-E1 EP7-EE cul Type 1/12/4/4x E P66 KS7-OS1 113 KWKstarter Enclosures for use with A7 ontactors and Overload Relays ➊➎ omponent escription ontactor For Use With Overload Environmental Approvals atalog Number Price Enclosure for KWKstarter ➌ AK7/BK AK7/BK7-30E 43E A A7-30E 43E EP7-E1 E1F EP7-EE EEF EP7S-EET cul Type 1/12/4/4x E P66 KS7-2S4 130 Enclosure for Reversing KWKstarter ➍ AUK AUK7-9E 23E AU AU7-9E...23E EP7-E1AB E1EB EP7-EEAB EEEB cul Type 1/12/4/4x E P66 KS7-0S4R 127 ➊ KWKstarters are only designed to accommodate A contactors with T7N Thermal Overload Relays or EP7 Solid State Overload Relays. f ordering components, select contactor from Section A and overload relay from Section B in this catalog. ➋ KS7-OS4 and KS7-OS1 may be used with either EP7 or T7N (field interchangeable). ➌ KWKstarter enclosure KS7-2S4 are designed to fit A7-30(E) 43(E) contactors with EP7 Overload Relays. T7N Thermal Overloads can not be substituted. ➍ KWKstarter enclosure KS7-0S4R are designed to fit AU7-9(E) 23(E) reversing contactors with EP7 Overload Relays. T7N Thermal Overloads can not be substituted. ➎ KS7-2S4 and KS7-0S4R are supplied with two 22mm holes for Pilot evices. A Reset is required and one additional pilot device kit from page 29 must be selected. Use of a PT is not possible. 28 iscount Schedule B7

29 KWKstarters Series AK7 & BK7 KWKstarter omponents with T7N or EP7 Overload Relays (for use with KS7-0S1/KS7-0S4) omponent escription For Use With... atalog Number Price Start - ontact kit Specially designed NO auxiliary; mechanically interfaces with the START button. ounts on right side. A KS7-PK is included in every KS7-OS4 enclosure. Pushbutton Latch - For maintain contact control (2-wire control) KS7-OS4 (Replacement Part) KS7-PK 16 KS7-OS4 KS7-PLA 8 KWKstarters Neutral Terminal KS7-OS1 KS7-OS4 KS7-PNT 12 Grounding Kit (for use with metal conduit) All KWKstarter enclosures KS7-GR1 13 KWKstarter Pilot evice Kits (for use with KS7-2S4/KS7-0S4R) ➊ Kits escription ulti-function Pushbutton kit Non-illuminated START-STOP -O FOR-STOP-REV UP-STOP-OWN OPEN-STOP-LOSE Selector switch kits Non-illuminated, includes legend plate ON-OFF 2-Position FOR-OFF-REV 3-Position UP-OFF-OWN 3-Position OPEN-OFF-LOSE 3-Position For Use With Enclosure... KS7-2S4 Type 1, 12, 4, 4X KS7-0S4R Type 1, 12, 4, 4X ontact Blocks included NO N atalog Number KS7-P3U KS7-P4U KS7-P3U-REV KS7-P4U-REV KS7-P5U-REV Price KS7-2S4 Type 1, 12, 4, 4X 1 - KS7-P6 40 KS7-0S4R Type 1, 12, 4, 4X 2 - KS7-P6-REV KS7-P7-REV KS7-P8-REV Reset Pushbutton, Blue Plastic push button, flush operator with Blue ap and R text KS7-2S4 KS7-0S4 Black Plastic with Blue ap and White R 7P-F611 ➋ ➊ Plastic bezel is standard. Pilot evice Kits include 7-BX_ Base ounted contact blocks. See page H69 for more information. ➋ 7P-R611 and EP7-ERA can not be used with KS7-2S4 or KS7-0S4R. See Section H for more information. iscount Schedule B7 29

30 KWKstarters Series AK7 & BK7 KWKstarters KWKstarters with EP7 Solid State Overload Relay 3-Phase Application ➋➌ For use with KWKstarter... Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) Price Adder 3-Phase / anual Reset / lass AB EP7-E1AB BB EP7-E1BB +9 AK7-9...AK B EP7-E1B B EP7-E1B EB EP7-E1EB +9 3-Phase / Selectable Function and lass EAB EP7-EEAB EBB EP7-EEBB +17 AK7-9...AK EB EP7-EEB EB EP7-EEB EEB EP7-EEEB +17 KWKstarters with EP7 Solid State Overload Relay 1-Phase Application ➋➌ For use with KWKstarter... Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) Price Adder 1-Phase / Selectable Function and lass EPB EP7S-EEPB +15 BK7-9...BK ERB EP7S-EERB ESB EP7S-EESB +15 KWKstarters with T7N Bimetallic Overload Relays ➊ For use with Kwikstarter... AK7-9...AK7-23 and BK7-9...BK7-23 Frame A Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) Price Adder AA16 T7N-23-A16 Standard AA25 T7N-23-A25 Standard AA40 T7N-23-A40 Standard AA50 T7N-23-A50 Standard AA63 T7N-23-A63 Standard AA80 T7N-23-A80 Standard AB10 T7N-23-B10 Standard AB13 T7N-23-B13 Standard AB16 T7N-23-B16 Standard AB20 T7N-23-B20 Standard AB25 T7N-23-B25 Standard AB32 T7N-23-B32 Standard AB40 T7N-23-B40 Standard AB48 T7N-23-B48 Standard AB63 T7N-23-B63 Standard AB75 T7N-23-B75 Standard A10 T7N Standard A12 T7N Standard A16 T7N Standard A20 T7N Standard A21 T7N Standard A25 T7N Standard This item is available in the ORANGE E PRESS 3-day shipping program ➊ f using T7N in single phase application with BK7-9 23, wire per drawing on page 31. ➋ EP7 Overloads are available for use in KWKStarters if the premium features are required (see Section B). ➌ 3-phase EP7-E or EP7-EE units are only designed for 3 applications. Single phase EP7S units are only designed for 1 applications. f using EP7S, wire per drawing on page iscount Schedule B7

31 Wiring iagrams KWKstarters KWKstarter (in enclosure KS7-0S1/0S4) USTOER UST PROVE PROPER BRANH RUT PROTETON (F1) SEE THE APPLATON NSTRUTON SHEET - OPONENT SELETON TABLES FOR AX. FUSE SZE & LASS AN APPLABLE SHORT RUT RATNG (USE 75º OPPER WRE ONLY) KWKstarters THS RAWNG S FOR THE FOLLOWNG ENLOSURES: KS7-0S4 with integrated START-STOP push buttons KS7-0S1 with integrated RESET push button NOTES: 1) EHANAL LATH KS7-PLA FOR AANTANE ONTROL (OPTONAL). 2) START ONTAT KT KS7-PK (NLUE) OUNTS ON THE RGHT SE WTH OLE PRE-FORE JUPERS. 3) O NOT WRE ONTROLS RUT TO LNE SE OF ONTATOR WHEN OL VOLTAGE S 120V OR LESS. (FATORY WRNG STANAR) 4) OPTONAL PLOT LGHTS. KWKstarter (in enclosure KS7-2S4) 31

32 [10mm] 1 nch SALE: Wiring iagrams KWKstarters Reversing KWKstarter (in enclosure KS7-0S4R) KWKstarters KWKstarter (in enclosure KS7-0S1) with HOA option HAN-OFF-AUTO with Pilot Light [8.19] 111 [4.37] 27.9 [1.10] A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK7 24Z 24V 24V Separate Separate V 120V ommon Separate 208 ~ 208V ~ ommon 220W 200V-220V 208V-240V ommon ommon V 240V ommon ommon 32

33 [10mm] 1 nch SALE: [10mm] 1 nch SALE: imensions KWKstarters EERGENY STOP with ULT-FUNTON KWKstarter (in enclosure KS7-OS1) with Emergency Stop option [8.19] 111 [4.37] 32.1 [1.26] KWKstarters A.. Voltage Range ontrol Source oil ode 50 Hz 60 Hz BK7 AK7 24Z 24V 24V Separate Separate V 120V ommon Separate 208 ~ 208V ~ ommon 220W 200V-220V 208V-240V ommon ommon V 240V ommon ommon KWKstarter Enclosure KS7-0S1/0S4 (imension ode Q1) imensions are in millimeters (inches). imensions not intended for manufacturing purposes Extended STOP [0.99] 19.5 [0.77] 44.5 [1.75] [8.19] 188 [7.41] [0.94] [1.24] 188 [7.41] 205 [8.08] ø5.3 [ ø0.21] ø20.3 [ ø0.80] 51 [2.01] 23.7 [0.94] 36.5 [1.44] 60.3 [2.38] 68 [2.68] 36.5 [1.44] 188 mm Ø " 0.2" A 97.9 [3.86] 111 [4.37] 5.5 [0.22] 111 [4.37] ø25.3 [ø 1.00] [0.22] Pozidriv No. 2 (1.2 x 6.5) 2.0 Nm 18 lb-in 2 x mm² 2 x No AWG Pozidriv No Nm 20 lb-in 33

34 imensions KWKstarters KWKstarter Enclosure KS7-2S4 (imension ode Q2) imensions are in millimeters (inches). imensions not intended for manufacturing purposes. 125 [4.93] 125 [4.93] 16 [0.63] KWKstarters 250 [9.85] 169 [6.66] 13 [0.51] 3.5 [0.14] Ø23 [Ø0.91] [4.48] 235 [9.26] 78 [3.07] 30 [1.18] 50 [1.97] 110 [4.33] 125 [4.93] 50 [1.97] 24 [0.95] 28.1 [1.11] Rotary operator alternatively (for maintained control) 50 [1.97] 10 Pozidriv No. 2 (1.2 x 6.5) 2.0 Nm 18 lb-in 2 x mm² 2 x No AWG Pozidriv No Nm 20 lb-in KWKstarter Enclosure KS7-0S4R (imension ode Q3) 125 [4.93] 125 [4.93] 16 [0.63] 250 [9.85] 13 [0.51] 3.5 [0.14] 235 [9.26] Ø23 [Ø0.91] 100 [3.94] [4.39] 30 [1.18] 88.6 [3.49] 50 [1.97] 110 [4.33] 125 [4.93] 50 [1.97] 28.1 [1.11] 50 [1.97] Rotary operator alternatively (for maintained control) 24 [0.95] 10 Pozidriv No. 2 (1.2 x 6.5) 2.0 Nm 18 lb-in 2 x mm² 2 x No AWG Pozidriv No Nm 20 lb-in 34

35 Enclosed ontactors Sprecher + Schuh s popular contactor lines housed in a variety of enclosures Sprecher + Schuh s broad line of E/UL HP rated contactors can be purchased pre-installed in a variety of standard enclosures. ataloged enclosures include: Type 1 Type 12 Type 3R Type 4 General Purpose ndustrial usttight Raintight (outdoor) Type 4X, orrosion Resistant Non-etallic Even though these are the most popular enclosure types for most industrial applications, we can house any contactor in a custom enclosure of your choice. Quality enclosures ensure the highest confidence Sprecher + Schuh only sources enclosures from name brand manufacturers, ensuring the highest quality. We primarily use enclosures that meet UL Standards, i.e., Type 1, Type 3R, etc., however, we can also source E-type enclosures at your request. Enclosures are sized first to accommodate the depth of the contactor and offer sufficient electrical clearances to satisfy UL. Add a variety of modifications f you need a larger enclosure than what is specified in our catalog, your sales representative and our Engineering department will work with you to customize any of our enclosed products to suit your exact specifications. Any combination of enclosure types, sizes, pilot devices, meters and other modifications can be combined to provide exactly the panel you need. Precisely match the contactor to the application Unique to E-style contactors is the ability to select the exact device required for a specific application. By identifying the conditions under which the contactor will be used, i.e., resistive loads, reversing, inching and plugging, etc., published life-curve data predicts contact life in millions of operations. This information enables you to select the precise contactor for your application without buying too much or too little. Refer to Section A in this catalog for detailed technical information on all Sprecher + Schuh contactors. Other unique features Virtually all Sprecher+Schuh contactors offer one or more of the latest design techniques and innovations, such as electronically controlled coils, field installable auxiliary contacts or universal accessories across the entire contactor family. Enclosed ontactors Type 1 Type 3R Type 4 Type 4X 35

36 Enclosed ontactors - A oil Non-Reversing Three Phase - Series A Enclosed ontactors Three Phase, Non-Reversing A7 & A9 ontinuous Amp Rating - UL/SA - aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➌ Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Enclosed 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ A7-9- -G0 211 A A L A G0 244 A A L A G0 259 A A L A G0 276 A A L A G0 324 A A L A G0 365 A A L A G0 520 A A L A G0 540 A A L A G0 560 B A A G0 617 B A A G0 674 B A A G0 848 B A O A G0 ➍ 1424 E A ➍ 1592 Q A G0 ➍ 1652 E A ➍ 1847 Q A G0 ➍ 1938 E A ➍ 2386 R A G0 ➍ 2601 F A ➍ 3290 T A G0 ➍ 2775 F A ➍ 3429 T A G0 ➍ 3272 H A ➍ 3740 H A G0 ➍ 3763 H A ➍ 4300 H A9-400-E- -G R/F A9-400-E R/F A9-460-E- -G R/F A9-460-E R/F A9-580-E- -G R/F A9-580-E R/F A9-750-E- -G R/F A9-750-E R/F 860 ~ A9-860-E- -G R/F A9-860-E R/F 1060 ~ A E- -G R/F A E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available Refer to page 104 Refer to pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example catalog number A becomes A R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ A9-116 A9-370 contactors are available with E option for PL interface. hange catalog number to include -E. Example: A G0 becomes A9-116-E- -G0. See page 104 for price adder. 36 iscount Schedule B7

37 Enclosed ontactors - A oil Non-Reversing Three Phase - Series A Three Phase, Non-Reversing A7 & A9 ontinuous Amp Rating - UL/SA - aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➋ Type 4 Type 4X orrosion Resistant Non-metallic Enclosed 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ A7-9- -W0 446 N A S A W0 479 N A S A W0 495 N A S A W0 513 N A S A W0 560 N A S A W0 600 N A S A W0 617 N A S A W0 653 N A S1 Enclosed ontactors A W0 754 O A U A W0 811 O A U A W0 869 O A U A W0 985 O A U A W0 ➍ 2011 Q A ➍ 1810 W A W0 ➍ 2333 Q A ➍ 2100 W A W0 ➍ 2565 R A ➍ 3429 X A W0 ➍ 3412 T A ➍ 4387 X A W0 ➍ 3545 T A ➍ 4469 X A W0 ➍ 4206 H A ➍ 5297 Y A W0 ➍ 4837 H A ➍ 6092 Y A9-400-E- -W R/F A9-400-E R/F A9-460-E- -W R/F A9-460-E R/F A9-580-E- -W R/F A9-580-E R/F A9-750-E- -W R/F A9-750-E R/F 860 ~ A9-860-E- -W R/F A9-860-E R/F 1060 ~ A E- -W R/F A E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available Refer to page 104 Refer to pages ➊ imensional information starts on page 122. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ A9-116 A9-370 contactors are available with E option for PL interface. hange catalog number to include -E. Example: A W0 becomes A9-116-E- -W0. See page 104 for price adder. iscount Schedule B7 37

38 Enclosed ontactors - A oil Reversing Three Phase - Series AU Enclosed ontactors Three Phase, Reversing AU7 & AU9 ontinuous Amp Rating - UL/SA - aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➌ Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Enclosed 200V 230V 460V 575V NO N ➍ atalog Number Price ➊ atalog Number Price ➊ AU7-9- -G0 562 A AU AU G0 633 A AU AU G0 674 A AU AU G0 692 A AU AU G0 807 A AU AU G0 888 A AU AU G0 953 B AU AU G B AU AU G AU O AU G AU O AU G AU O AU G AU O AU G0 ➎ 2681 E AU ➎ 2848 Q AU G0 ➎ 3110 E AU ➎ 3304 Q AU G0 ➎ 3877 E AU ➎ 4175 R AU G0 ➎ 5362 F AU ➎ 5850 T AU G0 ➎ 5702 F AU ➎ 6165 T AU G0 ➎ 6387 H AU ➎ 6855 H AU G0 ➎ 7345 H AU ➎ 7883 H AU9-400-E- -G R/F AU9-400-E R/F AU9-460-E- -G R/F AU9-460-E R/F AU9-580-E- -G R/F AU9-580-E R/F AU9-750-E- -G R/F AU9-750-E R/F 860 ~ AU9-860-E- -G R/F AU9-860-E R/F 1060 ~ AU E- -G R/F AU E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available Refer to page 104 Refer to pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example catalog number AU becomes AU R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On AU7 reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). ➎ AU9-116 AU9-370 contactors are available with E option for PL interface. hange catalog number to include -E. Example: AU G0 becomes AU9-116-E- -G0. See page 104 for price adder. 38 iscount Schedule B7

39 Enclosed ontactors - A oil Reversing Three Phase - Series AU Three Phase, Reversing AU7 & AU9 ontinuous Amp Rating - UL/SA - aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➋ Type 4 Type 4X orrosion Resistant Non-metallic Enclosed 200V 230V 460V 575V NO N ➌ atalog Number Price ➊ atalog Number Price ➊ AU7-9- -W0 668 N AU U AU W0 733 N AU U AU W0 774 N AU U AU W0 814 N AU U AU W0 904 N AU U AU W N AU U AU W N AU U AU W N AU U1 Enclosed ontactors AU W O AU V AU W O AU V AU W O AU V AU W O AU V AU G0 ➍ 3282 Q AU ➍ 3030 W AU G0 ➍ 3807 Q AU ➍ 3515 W AU G0 ➍ 4569 R AU ➍ 5692 X AU G0 ➍ 6490 T AU ➍ 7348 X AU G0 ➍ 6775 T AU ➍ 7317 X AU G0 ➍ 7357 H AU ➍ 8532 Y AU G0 ➍ 8461 H AU ➍ 9812 Y AU9-400-E- -G R/F AU9-400-E R/F AU9-460-E- -G R/F AU9-460-E R/F AU9-580-E- -G R/F AU9-580-E R/F AU9-750-E- -G R/F AU9-750-E R/F 860 ~ AU9-860-E- -G R/F AU9-860-E R/F 1060 ~ AU E- -G R/F AU E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available Refer to page 104 Refer to pages ➊ imensional information starts on page 122. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ One N.. auxiliary contact is used for electrical interlocking. On AU7 reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). ➍ AU9-116 AU9-370 contactors are available with E option for PL interface. hange catalog number to include -E. Example: AU W0 becomes AU9-116-E- -W0. See page 104 for price adder. iscount Schedule B7 39

40 Enclosed ontactors - A oil Non-Reversing Single Phase - Series B Enclosed ontactors Single Phase, Non-Reversing B7 ontinuous Amp Rating - UL/SA - aximum Horsepower Single Ø Auxiliary ontacts per ontactor ➌ Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic Enclosed 115V 230V NO N atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ B7- B7- B7- B7-25 1/2 1 1/ G0 211 A L 9- -W0 446 N S1 25 1/ G0 244 A L 12- -W0 479 N S G0 259 A L 16- -W0 495 N S G0 276 A L 23- -W0 513 N S G0 324 A L 30- -W0 560 N S G0 365 A L 37- -W0 600 N S / G0 520 A L 43- -W0 617 N S G0 540 A L 55- -W0 653 N S G0 560 B W0 754 O U G0 617 B W0 811 O U / G0 674 B W0 869 O U1 Larger sizes available. ontact your Sprecher + Schuh representative. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available Refer to page 104 Refer to pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example catalog number B becomes B R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. 40 iscount Schedule B7

41 Enclosed ontactors - A oil Reversing Single Phase - Series BU Single Phase, Reversing BUR7 (Reconnectable Winding - Three Lead otor) ontinuous Amp Rating - UL/SA - aximum Horsepower Single Ø Auxiliary ontacts per ontactor ➌ Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic Enclosed 115V 230V NO N ➍ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUR BUR BUR BUR 25 1/2 1 1/ G0 562 A W0 668 N U1 25 1/ G0 635 A W0 733 N U G0 676 A W0 774 N U G0 692 A W0 814 N U G0 807 A W0 904 N U1 Single Phase, Reversing BUS7 (Series Winding Four Lead Repulsion nduction otor) ontinuous Amp Rating - UL/SA - aximum Horsepower Single Ø Auxiliary ontacts per ontactor ➌ Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic Enclosed 115V 230V NO N ➍ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUS BUS BUS BUS 25 1/2 1 1/ G0 562 A W0 668 N U1 25 1/ G0 635 A W0 731 N U G0 676 A W0 774 N U G0 692 A W0 814 N U G0 807 A W0 904 N U1 Enclosed ontactors Single Phase, Reversing BUP7 (Parallel Winding Four Lead apacitor or Split Phase otor) ontinuous Amp Rating - UL/SA - aximum Horsepower Single Ø Auxiliary ontacts per ontactor ➌ Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic Enclosed 115V 230V NO N ➍ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUP BUP BUP BUP 25 1/2 1 1/ G0 562 A W0 668 N U1 25 1/ G0 635 A W0 731 N U G0 676 A W0 774 N U G0 692 A W0 814 N U G0 807 A W0 904 N U1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available Refer to page 104 Refer to pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number BUx becomes BUx R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On BU reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). iscount Schedule B7 41

42 NEA Enclosed ontactors - A oil Non-Reversing Three Phase - Series AN7 Enclosed ontactors Three Phase, Non-Reversing AN7 NEA Size aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➌ Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ AN G0 384 A AN L AN G0 409 A AN L AN G0 575 A AN L AN G0 819 A AN L AN G B AN NEA Size aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➌ Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ AN W0 755 N AN S AN W0 779 N AN S AN W0 946 N AN S AN W0 971 N AN S AN W O AN U1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available Refer to page 104 Refer to pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AN becomes AN R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. 42 iscount Schedule B8

43 NEA Enclosed ontactors - A oil Reversing Three Phase - Series AUN7 Three Phase, Reversing AUN7 NEA Size aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➌ Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight 200V 230V 460V 575V NO N ➍ atalog Number Price ➊ atalog Number Price ➊ AUN G0 997 A AUN AUN G A AUN AUN G A AUN AUN G B AUN AUN G AUN O NEA Size aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➌ Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V NO N ➍ atalog Number Price ➊ atalog Number Price ➊ AUN W N AUN U1 Enclosed ontactors AUN W N AUN U AUN W N AUN U AUN W N AUN U AUN W O AUN V1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available Refer to page 104 Refer to pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number AUN becomes AUN R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On AU7 reversing contactors, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). iscount Schedule B8 43

44 Enclosed Lighting ontactors - A oil Three Phase - Series AL / AVL Enclosed ontactors Electrically Held with A oil ontinuous Ampere Rating ➌ See page A46 Number of Poles Standard Auxiliary ontacts ➎ Type 1 General Purpose NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Type 12 [Type 3R ➏] ndustrial usttight NO N atalog Number Price ➍ atalog Number Price ➍ AL G0 414 A AL L AL G0 588 A AL L AL G0 980 B AL echanically Held with A oil ➊ ontinuous Ampere Rating ➌ Number of Poles Standard Auxiliary ontacts ➎ Type 1 General Purpose Type 12 [Type 3R ➏] ndustrial usttight NO N atalog Number Price ➍ atalog Number Price ➍ AVL G0 R/F R/F AVL R/F R/F See page AVL G0 R/F R/F AVL R/F R/F A AVL G0 R/F R/F AVL R/F R/F Larger sizes available. ontact your Sprecher + Schuh representative. escription The AL7 electrically held contactors and AVL7 mechanical held contactors are cul rated and labeled for tungsten and ballast lighting duty applications at 20, 30, and 60 amperes respectively. Operation of echanically Held ontactor with ON-OFF Pushbutton atalog number AVL7 consists of a AL7 contactor with V7-11 mechanical latch. epressing the ON button energizes the L coil and the contactor closes. The mechanical latch locks the contactor in the closed position. The L coil is then de-energized by the coil, clearing contact UL (Terminals 65-66) to remove voltage. epressing the OFF button energizes the UL coil, and the mechanical latch releases the contactor. The UL coil is immediately de-energized by the coil clearing contact L (Terminals 13-14) to remove voltage. The contactor is now open. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Factory odifications available 44 Refer to page 104 Refer to pages ➊ The N.O. auxiliary is used to mechanically latch the control circuit and is not available for use by customer for other uses. ➌ Engineering practice permits 2.5 x e to be applied to a contactor when 3 poles are connected in parallel for single phase discharge lamp (ballast lighting) applications. Example: A AL Lighting ontactor plus a A7-P-B23 Paralleling Link can be used on a 50A ballast load. Applying parallel conductors to incandescent lamp loads does NOT result in a greater permissible load. Paralleling Links can be found in the Accessories section. ➍ imensional information starts on page 122. ➎ ontactors are equipped with number and type of auxiliaries indicated. See 108 to order additional or different auxiliary contacts. ➏ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example: AL becomes AL R0. Price remains the same. iscount Schedule B7

45 Open and Enclosed Non-ombination otor Starters Built to your specifications and ready to install Type 1 Type 3R Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase and assembly of a separate contactor, overload relay and associated wiring. When purchased with an enclosure, the starters are mounted and ready to install on receipt. Starting with the best At the heart of all magnetic starters is the Sprecher + Schuh AT7 and AT9 line of motor starters. These starters are compact and offer intermediate sizes to better match specific motor requirements. This equates to generous wiring space and less wasted horsepower capacity. Top line protection agnetic starters are equipped with Sprecher + Schuh s premium EP7 solid state overload relay standard. Unlike traditional overload relays that indirectly sense motor current through heater elements, EP7 solid state overload relays measure motor current directly through integrated current transformers and on board electronics. The electronics provide numerous advantages over electromechanical relays. Alternatively, the T7N Thermal Overload Relay may also be selected. The right enclosure whatever the application Sprecher + Schuh s broad line of E style starters can be purchased pre-installed in a variety of standard enclosures. ataloged enclosures include: Type 1 Type 12 General Purpose ndustrial usttight applications, we can house any starter in a custom enclosure of your choosing. Quality enclosures ensure the highest confidence Sprecher + Schuh only sources enclosures from name brand manufacturers, ensuring the highest quality. We primarily use enclosures that meet UL Standards, i.e., Type 1, Type 3R, etc., however, we can also source E-type enclosures at your request. Enclosures are sized first to accommodate the depth of the contactor and offer sufficient electrical clearances to satisfy UL. Add a variety of modifications f you need a larger enclosure than what is specified in our catalog, your sales representative and our Engineering department will work with you to customize any of our enclosed products to suit your exact specifications. Any combination of enclosure types, sizes, pilot devices, meters and other modifications can be combined to provide exactly the panel you need. Non-ombination Starters Type 3R Raintight (outdoor) Type 4 Type 4X, orrosion Resistant Even though these are the most popular enclosure types for most industrial Type 4 Type 4X 45

46 Non-ombination otor Starters Non-Reversing Three Phase - Series AT Non-ombination Starters Three Phase, Non-Reversing AT7 & AT9 aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➌ Open Type Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight 200V 230V 460V 575V NO N atalog No. Price atalog No. Price ➊ atalog No. Price ➊ /2 1 0 AT AT G0 293 A AT L / AT AT G0 325 A AT L AT AT G0 350 A AT L 5 7 1/ AT AT G0 366 A AT L 7 1/ AT AT G0 447 A AT L AT AT G0 489 A AT L AT AT G0 576 A AT AT AT G0 612 A AT AT AT G0 766 B AT O AT AT G0 814 B AT O AT AT G0 880 B AT O AT AT G O AT O AT ➍ 1515 AT G0 ➍ 2104 E2 AT ➍ 2482 R AT ➍ 1757 AT G0 ➍ 2441 G AT ➍ 2879 T AT ➍ 2247 AT G0 ➍ 2958 G AT ➍ 3370 T AT ➍ 3592 AT G0 ➍ 4326 G AT ➍ 4760 T AT ➍ 3639 AT G0 ➍ 5111 AT ➍ AT ➍ 3913 AT G0 ➍ 5636 AT ➍ AT ➍ 4500 AT G0 ➍ 6481 AT ➍ AT9-400-E AT9-400-E- - -G R/F AT9-400-E R/F AT9-460-E AT9-460-E- - -G R/F AT9-460-E R/F AT9-580-E AT9-580-E- - -G R/F AT9-580-E R/F AT9-750-E AT9-750-E- - -G R/F AT9-750-E R/F ~ AT9-860-E AT9-860-E- - -G R/F AT9-860-E R/F ~ AT E AT E- - -G R/F AT E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AT becomes AT R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AT becomes AT9-116-E- -. See page 104 for price adder. 46 iscount Schedule B7

47 Non-ombination otor Starters Non-Reversing Three Phase - Series AT Three Phase, Non-Reversing AT7 & AT9 aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➋ Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V NO N atalog No. Price ➊ atalog No. Price ➊ /2 1 0 AT W0 554 N AT S / AT W0 587 N AT S AT W0 611 N AT S / AT W0 627 N AT S1 7 1/ AT W0 725 O AT U AT W0 774 O AT U AT W0 839 O AT U AT W0 874 O AT U AT W O AT U AT W O AT U AT W O AT U AT W O AT V AT W0 ➌ 2861 R2 AT ➌ 2693 W AT W0 ➌ 3319 T AT ➌ 3124 X AT W0 ➌ 3633 T AT ➌ 4344 X AT W0 ➌ 5061 T AT ➌ 5878 X AT W0 ➌ 6078 J AT ➌ 5884 X AT W0 ➌ 6418 J AT ➌ 6653 Y AT W0 ➌ 7381 J AT ➌ 7651 Y AT9-400-E- - -W R/F AT9-400-E R/F AT9-460-E- - -W R/F AT9-460-E R/F AT9-580-E- - -W R/F AT9-580-E R/F AT9-750-E- - -W R/F AT9-750-E R/F ~ AT9-860-E- - -W R/F AT9-860-E R/F ~ AT E- - -W R/F AT E R/F Non-ombination Starters NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AT W0 becomes AT9-116-E- - -W0. See page 104 for price adder. iscount Schedule B7 47

48 Non-ombination otor Starters Reversing Three Phase - Series AUT Non-ombination Starters Three Phase, Reversing AUT7 & AUT9 aximum Horsepower Auxiliary Open Type 1 Type 12 [Type 3R ➋] Three Phase ontacts per Type General ndustrial ontactor ➌ Purpose usttight 200V 230V 460V 575V NO N ➍ atalog No. Price atalog No. Price ➊ atalog No. Price ➊ /2 1 1 AUT AUT G0 652 A AUT / AUT AUT G0 717 A AUT AUT AUT G0 757 A AUT / AUT AUT G0 798 A AUT / AUT AUT G0 929 A AUT AUT AUT G A AUT AUT AUT G B AUT AUT AUT G B AUT AUT AUT G AUT O AUT AUT G AUT O AUT AUT G AUT O AUT AUT G AUT O AUT ➎ 2735 AUT G0 ➎ 3366 E2 AUT ➎ 3619 R AUT ➎ 3173 AUT G0 ➎ 3905 G AUT ➎ 4198 T AUT ➎ 4269 AUT G0 ➎ 5019 G AUT ➎ 5393 T AUT ➎ 6490 AUT G0 ➎ 7184 G AUT ➎ 7592 T AUT ➎ 6659 AUT G0 ➎ 8207 AUT ➎ AUT ➎ 7084 AUT G0 ➎ 8610 AUT ➎ AUT ➎ 8146 AUT G0 ➎ 9901 AUT ➎ AUT9-400-E AUT9-400-E- - -G R/F AUT9-400-E R/F AUT9-460-E AUT9-460-E- - -G R/F AUT9-460-E R/F AUT9-580-E AUT9-580-E- - -G R/F AUT9-580-E R/F AUT9-750-E AUT9-750-E- - -G R/F AUT9-750-E R/F ~ AUT9-860-E AUT9-860-E- - -G R/F AUT9-860-E R/F ~ AUT E AUT E- - -G R/F AUT E R/F NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number AUT becomes AUT R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On AUT7 reversing starters, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). ➎ AUT9-116 AUT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AUT becomes AUT9-116-E- -. See page 104 for price adder. 48 iscount Schedule B7

49 Non-ombination otor Starters Reversing Three Phase - Series AUT Three Phase, Reversing AUT7 & AUT9 aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➋ Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V NO N ➌ atalog No. Price ➊ atalog No. Price ➊ /2 1 1 AUT W0 749 N AUT U / AUT W0 814 N AUT U AUT W0 864 N AUT U / AUT W0 904 N AUT U1 7 1/ AUT W O AUT U AUT W O AUT U AUT W O AUT U AUT W O AUT U AUT W O AUT V AUT W O AUT V AUT W O AUT V AUT W O AUT V AUT W0 ➍ 3972 R2 AUT ➍ 3871 W AUT W0 ➍ 4608 T AUT ➍ 4490 X AUT W0 ➍ 5692 T AUT ➍ 6591 X AUT W0 ➍ 8001 T AUT ➍ 8980 X AUT W0 ➍ 9292 J AUT ➍ 9679 Y AUT W0 ➍ 9705 J AUT ➍ Y AUT W0 ➍ J AUT ➍ Y AUT9-400-E- - -W R/F AUT9-400-E R/F AUT9-460-E- - -W R/F AUT9-460-E R/F AUT9-580-E- - -W R/F AUT9-580-E R/F AUT9-750-E- - -W R/F AUT9-750-E R/F ~ AUT9-860-E- - -W R/F AUT9-860-E R/F ~ AUT E- - -W R/F AUT E R/F Non-ombination Starters NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ One N.. auxiliary contact is used for electrical interlocking. On AUT7 reversing starters, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). ➍ AUT9-116 AUT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AUT W0 becomes AUT9-116-E- - -W0. See page 104 for price adder. iscount Schedule B7 49

50 Non-ombination otor Starters Non-Reversing Single Phase - Series BT Single Phase, Non-Reversing BT7 Non-ombination Starters aximum Horsepower Single Ø Auxiliary ontacts per ontactor ➌ Open Type Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant 115V 230V NO N atalog No. Price atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BT7- BT7- BT7- BT7- BT7-1/2 1 1/ G0 293 A L W0 554 N S1 1/ G0 325 A L W0 587 N S G0 350 A L W0 611 N S G0 366 A L W0 627 N S G0 447 A L W0 721 O U G0 489 A L W0 770 O U / G0 576 A W0 833 O U G0 766 B O W O U G0 814 B O W O U1 7 1/ G0 880 B O W O U1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number BT becomes BT R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. 50 iscount Schedule B7

51 Non-ombination otor Starters Reversing Single Phase - Series BUT Single Phase, Reversing BUTR7 (Reconnectable Winding Three Lead otor) aximum Horsepower Single Ø Auxiliary ontacts per ontactor ➌ Open Type Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 115V 230V NO N ➍ atalog No. Price atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUTR7- BUTR7- BUTR7- BUTR7- BUTR7-1/2 1 1/ G0 652 A W0 749 N U1 1/ G0 717 A W0 814 N U G0 757 A W0 864 N U G0 798 A W0 904 N U G0 929 A W O U1 Single Phase, Reversing BUTS7 (Series Winding Four Lead Repulsion nduction otor) aximum Horsepower Single Ø Auxiliary ontacts per ontactor ➌ Open Type Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 115V 230V NO N ➍ atalog No. Price atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUTS7- BUTS7- BUTS7- BUTS7- BUTS7-1/2 1 1/ G0 652 A W0 749 N U1 1/ G0 717 A W0 814 N U G0 757 A W0 864 N U G0 798 A W0 904 N U G0 929 A W O U1 Non-ombination Starters Single Phase, Reversing BUTP7 (Parallel Winding Four Lead apacitor or Split Phase otor) aximum Horsepower Single Ø Auxiliary ontacts per ontactor ➌ Open Type Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 115V 230V NO N ➍ atalog No. Price atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ BUTP7- BUTP7- BUTP7- BUTP7- BUTP7-1/2 1 1/ G0 652 A W0 749 N U1 1/ G0 717 A W0 814 N U G0 757 A W0 864 N U G0 798 A W0 904 N U G0 929 A W O U1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number BUTx becomes BUTx R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➍ One N.. auxiliary contact is used for electrical interlocking. On AUT7 reversing starters, the N.. contact comes from the echanical/electrical nterlock unit (at # 7-02). iscount Schedule B7 51

52 Non-ombination Starters NEA NEA Sized Open and Enclosed Non-ombination otor Starters Built to your specifications and ready to install AN7 NEA labeled contactor (A) Sprecher + Schuh magnetic motor starters are intended to eliminate the purchase and assembly of a separate contactor, overload relay and associated wiring. When purchased with an enclosure, the starters are mounted and ready to install on receipt. Starting with the best At the heart of all Sprecher + Schuh NEA sized magnetic motor starters is the ATN7 line of motor starters. Each starter proudly displays the NEA size (00, 0, 1, 2, or 3) and HP at applied voltage. This line of starters is designed to meet rigid consultant specifications for NEA starters. Top line protection NEA labeled magnetic starters are equipped with Sprecher + Schuh s premium EP7 solid state overload relay standard. Unlike traditional overload relays that indirectly sense motor current through heater elements, EP7 solid state overload relays measure motor current directly through integrated current transformers and on board electronics. The electronics provide numerous advantages over electromechanical relays. Alternatively, the T7N Thermal Overload Relay may also be selected. The right enclosure whatever the application Sprecher + Schuh s line of NEA style starters can be purchased pre-installed in a variety of standard enclosures. ataloged enclosures include: Type 1 Type 12 Type 3R Type 4 Type 4X General Purpose ndustrial usttight Raintight (outdoor), orrosion Resistant Even though these are the most popular enclosure types for most industrial applications, we can house any starter in a custom enclosure of your choosing. Quality enclosures ensure the highest confidence Sprecher + Schuh only sources enclosures from name brand manufacturers, ensuring the highest quality. We primarily use enclosures that meet UL Standards, i.e., Type 1, Type 3R, etc., however, we can also source other enclosures at your request. Enclosures are sized first to accommodate the depth of the contactor and offer sufficient electrical clearances to satisfy UL. Add a variety of modifications f you need a larger enclosure than what is specified in our catalog, your sales representative and our Engineering department will work with you to customize any of our enclosed products to suit your exact specifications. Any combination of enclosure types, sizes, pilot devices, meters and other modifications can be combined to provide exactly the panel you need. 52 Type 1 Type 3R Type 4 Type 4X iscount Schedule B8

53 NEA Sized Non-ombination otor Starters Series ATN Three Phase, Non-Reversing ATN7 NEA Size aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➌ Open Type Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight 200V 230V 460V 575V NO N atalog Number Price atalog Number Price ➊ atalog Number Price ➊ /2 1-1/ ATN ATN G0 512 A ATN L ATN ATN G0 551 A ATN L 1 7-1/2 7-1/ ATN ATN G0 770 A ATN L ATN ATN G0 907 A ATN L ATN ATN G B ATN Three Phase, Non-Reversing ATN7 NEA Size aximum Horsepower Three Phase Auxiliary ontacts per ontactor ➌ Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V NO N atalog Number Price ➊ atalog Number Price ➊ /2 1-1/ ATN W0 924 N ATN S ATN W0 962 N ATN S /2 7-1/ ATN W N ATN U ATN W N ATN U ATN W O ATN U1 Non-ombination Starters NEA NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number ATN becomes ATN R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. iscount Schedule B8 53

54 NEA Sized Non-ombination otor Starters Series ATN Three Phase, Non-Reversing A Non-ombination Starter Non-ombination Starters NEA NEA Size ax HP 3-Phase ➊ Auxiliary ontacts per ontactor ➋ Type 1 etallic General Purpose 208V NO N atalog Number Price ➌ atalog Number Price ➌ ATN7-12-XA-1BB-G17-L A ATN7-12-XA-1BB-R17-L L ATN7-12-XA-1B-G17-L A ATN7-12-XA-1B-R17-L L ATN7-12-XA-1B-G17-L A ATN7-12-XA-1B-R17-L L ATN7-12-XA-1B-G17-L A ATN7-12-XA-1B-R17-L L ATN7-12-XA-1B-G17-L A ATN7-12-XA-1B-R17-L L ATN7-16-XA-1B-G17-L A ATN7-16-XA-1B-R17-L L ATN7-16-XA-1B-G17-L A ATN7-16-XA-1B-R17-L L ATN7-37-XA-1E-G17-L A ATN7-37-XA-1E-R17-L L ATN7-37-XA-1E-G17-L A ATN7-37-XA-1E-R17-L L ATN7-43-XA-1F-G17-L A ATN7-43-XA-1F-R17-L L ATN7-85-XA-EGE-G17-L B ATN7-85-XA-EGE-R17-L ATN7-85-XA-EGE-G17-L B ATN7-85-XA-EGE-R17-L ATN7-85-XA-EGE-G17-L B ATN7-85-XA-EGE-R17-L Type 3R etallic Outdoor Raintight Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T Reset pushbutton Three Phase, Non-Reversing A Non-ombination Starter NEA Size ax HP 3-Phase ➍ Auxiliary ontacts per ontactor ➋ Type 1 etallic General Purpose 230V NO N atalog Number Price ➌ atalog Number Price ➌ ATN7-12-XB-1BB-G17-L A ATN7-12-XB-1BB-R17-L L ATN7-12-XB-1B-G17-L A ATN7-12-XB-1B-R17-L L ATN7-12-XB-1B-G17-L A ATN7-12-XB-1B-R17-L L ATN7-12-XB-1B-G17-L A ATN7-12-XB-1B-R17-L L ATN7-12-XB-1B-G17-L A ATN7-12-XB-1B-R17-L L ATN7-16-XB-1B-G17-L A ATN7-16-XB-1B-R17-L L ATN7-16-XB-1B-G17-L A ATN7-16-XB-1B-R17-L L ATN7-37-XB-1E-G17-L A ATN7-37-XB-1E-R17-L L ATN7-37-XB-1E-G17-L A ATN7-37-XB-1E-R17-L L ATN7-43-XB-1F-G17-L A ATN7-43-XB-1F-R17-L L ATN7-43-XB-1F-G17-L A ATN7-43-XB-1F-R17-L L ATN7-85-XB-EGE-G17-L B ATN7-85-XB-EGE-R17-L ATN7-85-XB-EGE-G17-L B ATN7-85-XB-EGE-R17-L ATN7-85-XB-EGE-G17-L B ATN7-85-XB-EGE-R17-L Type 3R etallic Outdoor Raintight Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T Reset pushbutton This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 208V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ imensional information starts on page 122. ➍ HP and NEA size selection shown for 230V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. 54 iscount Schedule B8

55 NEA Sized Non-ombination otor Starters Series ATN Three Phase, Non-Reversing A Non-ombination Starter NEA Size ax HP 3-Phase ➊ Auxiliary ontacts per ontactor ➋ Type 1 etallic General Purpose 460V NO N atalog Number Price ➌ atalog Number Price ➌ ATN7-12-X-1BB-G17-L A ATN7-12-X-1BB-R17-L L ATN7-12-X-1B-G17-L A ATN7-12-X-1B-R17-L L ATN7-12-X-1B-G17-L A ATN7-12-X-1B-R17-L L ATN7-12-X-1B-G17-L A ATN7-12-X-1B-R17-L L ATN7-12-X-1B-G17-L A ATN7-12-X-1B-R17-L L ATN7-12-X-1B-G17-L A ATN7-12-X-1B-R17-L L ATN7-16-X-1B-G17-L A ATN7-16-X-1B-R17-L L ATN7-16-X-1B-G17-L A ATN7-16-X-1B-R17-L L ATN7-37-X-1E-G17-L A ATN7-37-X-1E-R17-L L ATN7-37-X-1E-G17-L A ATN7-37-X-1E-R17-L L ATN7-43-X-1F-G17-L A ATN7-43-X-1F-R17-L L ATN7-43-X-1F-G17-L A ATN7-43-X-1F-R17-L L ATN7-43-X-1F-G17-L A ATN7-43-X-1F-R17-L L ATN7-85-X-EGE-G17-L B ATN7-85-X-EGE-R17-L ATN7-85-X-EGE-G17-L B ATN7-85-X-EGE-R17-L ATN7-85-X-EGE-G17-L B ATN7-85-X-EGE-R17-L Type 3R etallic Outdoor Raintight Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T Reset pushbutton Non-ombination Starters NEA Three Phase, Non-Reversing A Non-ombination Starter NEA Size ax HP 3-Phase ➍ Auxiliary ontacts per ontactor ➋ Type 1 etallic General Purpose 575V NO N atalog Number Price ➌ atalog Number Price ➌ ATN7-12-X-1BB-G17-L A ATN7-12-X-1BB-R17-L L ATN7-12-X-1B-G17-L A ATN7-12-X-1B-R17-L L ATN7-12-X-1B-G17-L A ATN7-12-X-1B-R17-L L ATN7-12-X-1B-G17-L A ATN7-12-X-1B-R17-L L ATN7-12-X-1B-G17-L A ATN7-12-X-1B-R17-L L ATN7-16-X-1B-G17-L A ATN7-16-X-1B-R17-L L ATN7-16-X-1B-G17-L A ATN7-16-X-1B-R17-L L ATN7-37-X-1E-G17-L A ATN7-37-X-1E-R17-L L ATN7-37-X-1E-G17-L A ATN7-37-X-1E-R17-L L ATN7-43-X-1F-G17-L A ATN7-43-X-1F-R17-L L ATN7-43-X-1F-G17-L A ATN7-43-X-1F-R17-L L ATN7-43-X-1F-G17-L A ATN7-43-X-1F-R17-L L ATN7-85-X-EGE-G17-L B ATN7-85-X-EGE-R17-L ATN7-85-X-EGE-G17-L B ATN7-85-X-EGE-R17-L ATN7-85-X-EGE-G17-L B ATN7-85-X-EGE-R17-L Type 3R etallic Outdoor Raintight Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T Reset pushbutton This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 460V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ imensional information starts on page 122. ➍ HP and NEA size selection shown for 575V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. iscount Schedule B8 55

56 NEA Sized Non-ombination otor Starters Single Phase - Series BTN7 Single Phase, Non-Reversing BTN7 NEA Size aximum HP Single ø Auxiliary ontacts per ontactor ➌ Open Type Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Non-ombination Starters NEA 115V 230V NO N atalog Number Price atalog Number Price ➊ atalog Number Price ➊ 00 1/ BTN BTN G0 512 A BTN L BTN BTN G0 551 A BTN L BTN BTN G0 770 A BTN L /2 1 0 BTN BTN G0 939 A BTN L 3 7-1/ BTN BTN G B BTN Single Phase, Non-Reversing BTN7 NEA Size aximum HP Single ø Auxiliary ontacts per ontactor ➌ Type 4 Type 4X orrosion Resistant Non-metallic 115V 230V NO N atalog Number Price ➊ atalog Number Price ➊ 00 1/ BTN W0 924 N BTN S BTN W0 962 N BTN S BTN W N BTN U /2 1 0 BTN W N BTN U / BTN W O BTN U1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number BTN becomes BTN R0. Price remains the same. ➌ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. 56 iscount Schedule B8

57 NEA Sized Non-ombination otor Starters Single Phase - Series BTN7 Single Phase, Non-Reversing 120V A Non-ombination NEA Size ax HP 1-Phase ➊ Auxiliary ontacts per ontactor ➋ Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 120V NO N atalog No. Price ➌ atalog No. Price ➌ BTN ERB-G17-L A BTN ERB-R17-L L BTN ESB-G17-L A BTN ESB-R17-L L BTN ESB-G17-L A BTN ESB-R17-L L L BTN ESB-G17-L A BTN ESB-R17-L L BTN ET-G17-L A BTN ET-R17-L L BTN ET-G17-L A BTN ET-R17-L L BTN ET-G17-L A BTN ET-R17-L L BTN EUE-G17-L B BTN EUE-R17-L BTN EUE-G17-L B BTN EUE-R17-L Non-ombination Starters NEA Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Single-Phase EP7S electronic overload relay A coil Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use Reset pushbutton Single Phase, Non-Reversing 230V A Non-ombination NEA Size ax HP 1-Phase ➍ Auxiliary ontacts per ontactor ➋ Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 230V NO N atalog No. Price ➌ atalog No. Price ➌ BTN EPB-G17-L A BTN EPB-R17-L L BTN ERB-G17-L A BTN ERB-R17-L L BTN ERB-G17-L A BTN ERB-R17-L L BTN ERB-G17-L A BTN ERB-R17-L L BTN ESB-G17-L A BTN ESB-R17-L L BTN ESB-G17-L A BTN ESB-R17-L L BTN ET-G17-L A BTN ET-R17-L L BTN ET-G17-L A BTN ET-R17-L L BTN ET-G17-L A BTN ET-R17-L L BTN EUE-G17-L B BTN EUE-R17-L BTN EUE-G17-L B BTN EUE-R17-L Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Single-Phase EP7S electronic overload relay A coil Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use Reset pushbutton This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 120V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ imensional information starts on page 122. ➍ HP and NEA size selection shown for 230V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. iscount Schedule B8 57

58 ombination Starters ombination Starters - Through the oor Operated Smart and cost effective for any application Sprecher + Schuh s through-the-door operated combination starters represent an economical alternative to the classic flange-operated combo solution. t is designed to meet rigid UL/NE withstand specifications. Sprecher + Schuh has been building custom control panels with this design for years. Experience the durability of this product! Starting with the best At the heart of all combination starters is the Sprecher + Schuh AT7 and AT9 line of motor starters. These starters are compact and offer intermediate sizes to better match specific motor requirements. This equates to generous wiring space and less wasted horsepower capacity. Top line protection ombination starters are equipped with Sprecher + Schuh s premium EP7 solid state overload relay standard. Unlike traditional overload relays that indirectly sense motor current through heater elements, EP7 solid state overload relays measure motor current directly through integrated current transformers and on board electronics. The electronics provide numerous advantages over electromechanical relays. Alternatively, the T7N Thermal Overload Relay may also be selected. hoice of Enclosures Available enclosures include; Type 1 General Purpose Type 3R Raintight Type 12 usttight Type 4 Type 4X orrosion Resistant hoice of isconnect hoices for disconnect include: Thermal agnetic olded ase ircuit Breaker (B) L11 fusible or non-fusible isconnect switch otor ircuit ontroller (Section F) Thermal agnetic olded ase ircuit Breaker (B) The through-the-door operated combo B is available to meet UL short circuit withstand specifications. An B prevents single phasing by simultaneously opening all three phases when a fault occurs in any one phase. An B can often be reset after the fault has been cleared. isconnect Switches The through-the-door operated combo is available with the L11disconnect switch. A mechanical door interlock system prevents the door from being opened when the disconnect is closed, and conversely, prevents the disconnect from being closed when the door is open. Both functions can be defeated for test and maintenance purposes. Other safety features include padlock provisions and a high visibility operating handle. The L11 disconnect switch has a quick make/quick break, non-teasing action. The L11 fusible switch is suitable for interrupting up to 100,000 amperes when class J fuses are used. All L11 disconnect switches conform to UL 98 standards. 58

59 1 L1 3 L2 5 2 T1 4 T2 6 L3 T3 14 Open Type ombination Starters Thermal-agnetic ircuit Breaker (B)- Series AT Series AT7 with Thermal-agnetic ircuit Breaker ➊ aximum Horsepower Three Phase B Amps Open Type 200V 230V 460V 575V atalog No. ➌ Price ~ 15 AT TB15-BP AT TBH15-BP 877 ~ ~ ~ AT TBH20-BP ~ 20 AT TB20-BP AT TBH20-BP 914 ~ 5 10 ~ 30 AT TB30-BP ~ ~ ~ 35 AT TB35-BP ~ ~ AT TBH35-BP 987 ~ ~ 40 AT TB40-BP 856 ~ ~ ~ AT TBH40-BP ➋ 50 AT TB50-BP AT TBH50-BP ➋ 50 AT TB50-BP ~ AT TBH50-BP 1133 ~ ~ 30 ~ 70 AT TB70-BP 1038 ~ 15 ~ ~ 80 AT TB80-BP ➋ 80 AT TB80-BP AT TBH80-BP 1335 ~ ~ ~ 40 ➋ 80 AT TB80-BP 1235 ~ ~ ~ AT TBH80-BP ➋ 100 AT TB100-BP AT TBH100-BP ➋ 125 AT TB125-BP 1272 ~ 25 ~ AT TBH125-BP ~ 125 AT TB125-BP 1746 ~ 30 ~ 75 ➋ 125 AT TB125-BP 2124 ~ 30 ~ AT TBH125-BP 2257 Larger sizes available. ontact your Sprecher + Schuh representative. ➌ Open ombination Starters include the following: A7 ontactor with 1 Normally Open Auxiliary contact EP7 Overload Relay Thermal agnetic ircuit Breaker 19 x gauge steel back pan with black polyester powder paint finish 465mm TG. TR. (18.30") 133mm (5.25") 13 NO 483mm (19") ombination Starters odifications (Factory Assembled) ➊ escription A7 Auxiliaries & Trip ontacts - Side ount 1 NO Auxiliary 1 N Auxiliary 1 NO + 1 N Auxiliary 2 NO Auxiliaries 2 N Auxiliaries Add Suffix to atalog Number -L10 -L01 -L11 -L20 -L02 Price Adder T1 T2 T3 57mm TG. TR. (2.25") This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay See page 104 See pages NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying atalog Numbers. ➊ Open type combination starters are limited to standard coils, overload selections, and modifications listed on this page. ontact factory for additional modifications. ➋ Applicable to 600Y/347V only. Refer to page 61 for 600V elta enclosed solution. ontact your Sprecher + Schuh representative for an open type delta solution. ➌ Selections above the orange line should consider an E-ombo starter. See page F58. iscount Schedule B7 59

60 Through-the-door Operator ombination Starters Thermal-agnetic ircuit Breaker (B)- Series AT Series AT7 & AT9 with Thermal-agnetic ircuit Breaker ombination Starters aximum Horsepower Three Phase B Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AT AT AT AT ~ TB15G TB TB15W TB V ~ TB20G TB TB20W TB V2 ~ 5 10 ~ TB30G TB TB30W TB V2 5 ~ ~ ~ TB35G TB TB35W TB V2 ~ ~ TB40G TB TB40W TB V2 ~ ~ ~ 20 ➌ TB40G TB TB40W TB V ➌ TB50G TB TB50W TB V ➌ TB50G TB TB50W TB V2 ~ ~ 30 ~ TB70G TB TB70W TB V2 ~ 15 ~ ~ TB80G TB TB80W TB V ➌ TB80G TB TB80W TB V2 ~ ~ ~ 40 ➌ TB80G TB Q TB80W Q TB W ➌ TB100G TB Q TB100W Q TB W ➌ TB125G TB Q TB125W Q TB W ~ TB125G TB Q TB125W Q TB W2 ~ ~ ~ 75 ➌➍ TB150G TB Q TB150W Q TB W2 30 ➍ ~ 75 ➍ ~ TB175G TB Q TB175W Q TB W2 30 ~ 75 ~ TB175G0 ➎ 3853 E TB1750 ➎ 4355 R TB175W0 ➎ 4523 R TB1750 ➎ 6868 X1 ~ 40 ~ 100➌ TB200G0 ➎ 3853 E TB2000 ➎ 4355 R TB200W0 ➎ 4523 R TB2000 ➎ 6868 X1 40 ~ ➌ TB225G0 ➎ 4469 G TB2250 ➎ 5052 R TB225W0 ➎ 5247 R TB2250 ➎ 7967 X1 ~ 50 ~ ~ TB250G0 ➎ 4469 G TB2500 ➎ 5052 T TB250W0 ➎ 5247 T TB2500 ➎ 7967 X TB300G0 ➎ 4579 H TB3000 ➎ 5026 T TB300W0 ➎ 5324 T TB3000 ➎ 7113 X TB350G0 ➎ 7637 H TB3500 ➎ 8779 H TB350W0 ➎ 8937 H TB3500 ➎ 9749 A2 75 ~ 175 ~ TB400G0 ➎ 8476 H TB4000 ➎ 9729 H TB400W0 ➎ H TB4000 ➎ A TB450G0 ➎ 9046 H TB4500 ➎ H TB450W0 ➎ H TB4500 ➎ Y1 100 ~ ~ ~ TB500G0 ➎ TB5000 ➎ W TB500W0 ➎ J TB5000 ➎ Y1 ~ TB600G0 ➎ TB6000 ➎ W TB600W0 ➎ J TB6000 ➎ Y1 ~ ~ ~ TB600G0 ➎ TB6000 ➎ W TB600W0 ➎ J TB6000 ➎ Y ~ TB700G0 ➎ TB7000 ➎ W TB700W0 ➎ J TB7000 ➎ Y ~ E- - -TB700G J E- - -TB J E- - -TB700W J E- - -TB Y1 ~ ~ 350 ~ E- - -TB800G J E- - -TB J E- - -TB800W J E- - -TB Y1 150 ~ ~ ~ E- - -TB800G J E- - -TB J E- - -TB800W J E- - -TB Y1 ~ E- - -TB1000G J E- - -TB J E- - -TB1000W J E- - -TB Y1 200 ~ ~ E- - -TB1000G R/F E- - -TB R/F E- - -TB1000W R/F E- - -TB R/F ~ ~ E- - -TB1200G R/F E- - -TB R/F E- - -TB1200W R/F E- - -TB R/F Larger sizes available. ontact your Sprecher + Schuh representative. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AT TB500 becomes AT TB50R0. Price remains the same. ➌ Applicable to 600Y/347V only. Refer to page 61 for 600V elta solution. ➍ The short circuit and ka is relegated to the contactor s 10kA. ontact your Sprecher + Schuh representative for a higher ka. ➎ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AT TB175G0 becomes AT9-116-E- - -TB175G0. See page 104 for price adder. 60 iscount Schedule B7

61 Through-the-door Operator ombination Starters Thermal-agnetic ircuit Breaker (B)- Series AT Series AT7 & AT9 with Thermal-agnetic ircuit Breaker - 600V elta aximum Horsepower Three Phase B Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AT AT AT AT TBH15G TBH TBH15W TBH V2 ~ ~ ~ TBH20G TBH TBH20W TBH V TBH20G TBH TBH20W TBH V2 5 ~ ~ TBH35G TBH TBH35W TBH V2 ~ ~ ~ TBH40G TBH TBH40W TBH V TBH50G TBH TBH50W TBH V TBH50G TBH TBH50W TBH V TBH80G TBH TBH80W TBH V2 ~ ~ ~ TBH80G TBH Q TBH80W Q TBH W TBH100G TBH Q TBH100W Q TBH W2 ~ 25 ~ TBH125G TBH Q TBH125W Q TBH W2 ~ ~ ~ 75 ➌ TBH150G TBH Q TBH150W Q TBH W2 30 ~ 75 ~ TBH175G0 ➍ 4170 E TBH1750 ➍ 4700 R TBH175W0 ➍ 4840 R TBH1750 ➍ 7185 X1 ~ 40 ~ 100 ➌ TBH200G0 ➍ 4170 E TBH2000 ➍ 4700 R TBH200W0 ➍ 4840 R TBH2000 ➍ 7185 X1 40 ~ ➌ TBH225G0 ➍ 4837 G TBH2250 ➍ 5452 T TBH225W0 ➍ 5614 T TBH2250 ➍ 8335 X1 ombination Starters Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number AT TBH500 becomes AT TBH50R0. Price remains the same. ➌ The short circuit and ka is relegated to the contactor s 10kA. ontact your Sprecher + Schuh representative for a higher ka. ➍ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AT TBH175G0 becomes AT9-116-E- - -TBH175G0. See page 104 for price adder. iscount Schedule B7 61

62 Through-the-door Operator ombination Starters - Reversing Thermal-agnetic ircuit Breaker (B)- Series AUT Series AUT7 & AUT9 with Thermal-agnetic ircuit Breaker ombination Starters aximum Horsepower Three Phase B Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AUT AUT AUT AUT ~ TB15G TB Q TB15W Q TB V ~ TB20G TB Q TB20W Q TB V2 ~ 5 10 ~ TB30G TB Q TB30W Q TB V2 5 ~ ~ ~ TB35G TB Q TB35W Q TB V2 ~ ~ TB40G TB Q TB40W Q TB V2 ~ ~ ~ 20 ➌ TB40G TB Q TB40W Q TB V ➌ TB50G TB Q TB50W Q TB V ➌ TB50G TB Q TB50W Q TB V2 ~ ~ 30 ~ TB70G TB Q TB70W Q TB V2 ~ 15 ~ ~ TB80G TB Q TB80W Q TB V ➌ TB80G TB Q TB80W Q TB V2 ~ ~ ~ 40 ➌ TB80G TB Q TB80W Q TB W ➌ TB125G TB Q TB125W Q TB W ~ TB125G TB Q TB125W Q TB W2 ~ ~ ~ 75 ➌➍ TB150G TB Q TB150W Q TB W2 30 ➍ ~ 75 ➍ ~ TB175G TB Q TB175W Q TB W2 30 ~ 75 ~ TB175G0 ➎ 5402 E TB1750 ➎ 5737 R TB175W0 ➎ 6239 R TB1750 ➎ 9087 X1 ~ 40 ~ 100 ➌ TB200G0 ➎ 5402 E TB2000 ➎ 5737 R TB200W0 ➎ 6239 R TB2000 ➎ 9087 X1 40 ~ ➌ TB225G0 ➎ 6266 G TB2250 ➎ 6655 T TB225W0 ➎ 7237 T TB2250 ➎ X1 ~ 50 ~ ~ TB250G0 ➎ 6266 G TB2500 ➎ 6655 T TB250W0 ➎ 7237 T TB2500 ➎ X TB300G0 ➎ 6852 H TB3000 ➎ 7195 H TB300W0 ➎ 7597 H TB3000 ➎ A TB350G0 ➎ H TB3500 ➎ H TB350W0 ➎ H TB3500 ➎ Y1 75 ~ 175 ~ TB400G0 ➎ TB4000 ➎ W TB400W0 ➎ J TB4000 ➎ Y TB450G0 ➎ TB4500 ➎ W TB450W0 ➎ J TB4500 ➎ Y1 100 ~ ~ ~ TB500G0 ➎ TB5000 ➎ W TB500W0 ➎ J TB5000 ➎ Y1 ~ TB600G0 ➎ TB6000 ➎ W TB600W0 ➎ J TB6000 ➎ Y1 ~ ~ ~ TB600G0 ➎ J TB6000 ➎ W TB600W0 ➎ J TB6000 ➎ Y ~ TB700G0 ➎ J TB7000 ➎ W TB700W0 ➎ J TB7000 ➎ Y ~ E- - -TB700G J E- - -TB J E- - -TB700W J E- - -TB Y1 ~ ~ 350 ~ E- - -TB800G J E- - -TB J E- - -TB800W J E- - -TB Y1 150 ~ ~ ~ E- - -TB800G J E- - -TB J E- - -TB800W J E- - -TB Y1 ~ E- - -TB1000G J E- - -TB J E- - -TB1000W J E- - -TB Y1 200 ~ ~ E- - -TB1000G R/F E- - -TB R/F E- - -TB1000W R/F E- - -TB R/F ~ ~ E- - -TB1200G R/F E- - -TB R/F E- - -TB1200W R/F E- - -TB R/F Larger sizes available. ontact your Sprecher + Schuh representative. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number AUT TB500 becomes AUT TB50R0. Price remains the same. ➌ Applicable to 600Y/347V only. Refer to page 63 for 600V elta solution. ➍ The short circuit and ka is relegated to the contactor s 10kA. ontact your Sprecher + Schuh representative for a higher ka. ➎ AUT9-116 AUT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AUT TB175G0 becomes AUT9-116-E- - -TB175G0. See page 104 for price adder. 62 iscount Schedule B7

63 Through-the-door Operator ombination Starters - Reversing Thermal-agnetic ircuit Breaker (B)- Series AUT Series AUT7 & AUT9 with Thermal-agnetic ircuit Breaker - 600V elta aximum Horsepower Three Phase B Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AUT AUT AUT AUT TBH15G TBH Q TBH15W Q TBH V2 ~ ~ ~ TBH20G TBH Q TBH20W Q TBH V TBH20G TBH Q TBH20W Q TBH V2 5 ~ ~ TBH35G TBH Q TBH35W Q TBH V2 ~ ~ ~ TBH40G TBH Q TBH40W Q TBH V2 7.5 ~ TBH50G TBH Q TBH50W Q TBH V ~ TBH50G TBH Q TBH60W Q TBH V TBH80G TBH Q TBH80W Q TBH V2 ~ ~ ~ TBH80G TBH Q TBH80W Q TBH W TBH100G TBH Q TBH100W Q TBH W2 ~ 25 ~ TBH125G TBH Q TBH125W Q TBH W2 ~ ~ ~ 75 ➌ TBH150G TBH Q TBH150W Q TBH W2 30 ~ 75 ~ TBH175G0 ➍ 5719 E TBH1750 ➍ 6054 R TBH175W0 ➍ 6557 R TBH1750 ➍ 9404 X1 ~ 40 ~ 100 ➌ TBH200G0 ➍ 5719 E TBH2000 ➍ 6054 R TBH200W0 ➍ 6557 R TBH2000 ➍ 9404 X1 40 ~ ➌ TBH225G0 ➍ 6634 G TBH2250 ➍ 7023 T TBH225W0 ➍ 7606 T TBH2250 ➍ X1 ombination Starters Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number AUT TBH500 becomes AUT TBH50R0. Price remains the same. ➌ The short circuit and ka is relegated to the contactor s 10kA. ontact your Sprecher + Schuh representative for a higher ka. ➍ AUT9-116 AUT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AUT TBH175G0 becomes AUT9-116-E- - -TBH175G0. See page 104 for price adder. iscount Schedule B7 63

64 Through-the-door Operator ombination Starters Fusible isconnect - Series AT ombination Starters Series AT7 & AT9 with Fusible isconnect (J-Type) ➌➍ aximum Horsepower Three Phase Fuse lip Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AT AT AT AT JF61G JF JF61W Q JF V JF61G JF JF61W Q JF V JF61G JF JF61W Q JF V1 5 ~ ~ JF61G JF JF61W Q JF V1 ~ ~ JF62G JF JF62W Q JF V JF62G JF JF62W Q JF V JF62G JF JF62W Q JF V1 10 ~ JF62G JF JF62W Q JF V1 ~ 15 ~ ~ JF63G JF Q JF63W Q JF W1 ~ ~ ~ JF62G JF JF62W Q JF V ~ JF63G JF Q JF63W Q JF W1 ~ ~ ~ JF62G JF Q JF62W Q JF W JF63G JF Q JF63W Q JF W JF63G JF Q JF63W Q JF W2 ~ ~ ~ JF63G JF Q JF63W Q JF W ~ JF64G G JF T JF64W T JF X JF64G G JF T JF64W T JF X JF64G0 ➎ 3853 G JF640 ➎ 4355 T JF64W0 ➎ 4690 T JF640 ➎ 6030 A JF64G0 ➎ 4469 G JF640 ➎ 5052 T JF64W0 ➎ 5440 T JF640 ➎ 6995 A JF65G0 ➎ 5218 H JF650 ➎ 5665 H JF65W0 ➎ 5963 H JF650 ➎ 7901 Y JF65G0 ➎ 7312 H JF650 ➎ 7799 H JF65W0 ➎ 8287 H JF650 ➎ 9911 Y JF65G0 ➎ 8476 J JF650 ➎ 8938 J JF65W0 ➎ 9554 J JF650 ➎ Y JF66G0 ➎ 8973 R/F JF660 ➎ 9435 R/F JF66W0 ➎ R/F JF660 ➎ R/F JF66G0 ➎ 9464 R/F JF660 ➎ 9926 R/F JF66W0 ➎ R/F JF660 ➎ R/F ~ E- - -JF66G R/F E- - -JF R/F E- - -JF66W R/F E- - -JF R/F ~ ~ 350 ~ E- - -JF67G R/F E- - -JF R/F E- - -JF67W R/F E- - -JF R/F E- - -JF67G R/F E- - -JF R/F E- - -JF67W R/F E- - -JF R/F Larger sizes available. ontact your Sprecher + Schuh representative. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number AT JF620 becomes AT JF62R0. Price remains the same. ➌ Fusible combo starter uses the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➍ A Red and Yellow Handle may be selected instead of the standard Black handle. hange "JF" to "LF" in catalog number. ➎ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AT JF64G0 becomes AT9-116-E- - -JF64G0. See page 104 for price adder. 64 iscount Schedule B7

65 Through-the-door Operator ombination Starters - Reversing Fusible isconnect - Series AUT Series AUT7 & AUT9 with Fusible isconnect (J-Type) ➌➍ aximum Horsepower Three Phase Fuse lips Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AUT AUT AUT AUT JF61G JF Q JF61W Q JF V JF61G JF Q JF61W Q JF V JF61G JF Q JF61W Q JF V1 5 ~ ~ JF61G JF Q JF61W Q JF V ~ JF62G JF Q JF62W Q JF V JF62G JF Q JF62W Q JF V JF62G JF Q JF62W Q JF V1 10 ~ JF62G JF Q JF62W Q JF V1 ~ 15 ~ ~ JF63G E JF R JF63W R JF W1 ~ ~ ~ JF62G JF Q JF62W Q JF V ~ JF63G E JF R JF63W R JF W1 ~ ~ ~ JF62G E JF R JF62W R JF W JF63G E JF R JF63W R JF W JF63G E JF R JF63W R JF W2 ~ ~ ~ JF63G E JF R JF63W R JF W ~ JF64G F JF T JF64W T JF A JF64G F JF T JF64W T JF A JF64G0 ➎ 6030 H JF640 ➎ 6658 H JF64W0 ➎ 6993 H JF640 ➎ R/F Y JF64G0 ➎ 6995 H JF640 ➎ 7723 H JF64W0 ➎ 8112 H JF640 ➎ R/F Y JF65G0 ➎ 8200 J JF650 ➎ 8758 J JF65W0 ➎ 9057 J JF650 ➎ R/F Z JF65G0 ➎ J JF650 ➎ J JF65W0 ➎ J JF650 ➎ R/F Z JF65G0 ➎ J JF650 ➎ J JF65W0 ➎ J JF650 ➎ R/F Z JF66G0 ➎ R/F JF660 ➎ R/F JF66W0 ➎ R/F JF660 ➎ R/F R/F JF66G0 ➎ R/F JF660 ➎ R/F JF66W0 ➎ R/F JF660 ➎ R/F R/F ~ E- - -JF66G R/F E- - -JF R/F E- - -JF66W R/F E- - -JF660 R/F R/F ~ ~ 350 ~ E- - -JF67G R/F E- - -JF R/F E- - -JF67W R/F E- - -JF670 R/F R/F E- - -JF67G R/F E- - -JF R/F E- - -JF67W R/F E- - -JF670 R/F R/F Larger sizes available. ontact your Sprecher + Schuh representative. ombination Starters NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122 ➋ For Type 3R outdoor applications, replace in catalog number with an R. imensions may change. For example number AUT JF620 becomes AUT JF62R0. Price remains the same. ➌ Fusible combo starter used the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➍ A Red and Yellow Handle may be selected instead of the standard y and Black handle. hange JF to LF in catalog number. ➎ AUT9-116 AUT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AUT JF64G0 becomes AUT9-116-E- - -JF64G0. See page 104 for price adder. iscount Schedule B7 65

66 Through-the-door Operator ombination Starters Non-Fusible isconnect - Series AT ombination Starters Series AT7 & AT9 with Non-Fusible isconnect ➌➍ aximum Horsepower Three Phase Type 1 isc General Size/ Purpose Amps Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AT AT AT AT JU61G JU JU61W Q JU V JU61G JU JU61W Q JU V JU61G JU JU61W Q JU V JU61G JU JU61W Q JU V1 7.5 ~ ~ JU61G JU JU61W Q JU V1 ~ JU62G JU JU62W Q JU V JU62G JU JU62W Q JU V JU62G JU JU62W Q JU V1 15 ~ ~ JU62G JU JU62W Q JU V1 ~ ~ JU63G JU Q JU63W Q JU W2 15 ~ ~ ~ JU62G JU Q JU62W Q JU W2 ~ JU63G JU Q JU63W Q JU W JU63G JU Q JU63W Q JU W JU63G JU Q JU63W Q JU W2 ~ 30 ~ JU63G JU Q JU63W Q JU W2 30 ~ 75 ~ JU64G G JU T JU64W T JU X JU64G0 ➎ 3685 G JU640 ➎ 4188 T JU64W0 ➎ 4523 T JU640 ➎ 5863 A JU64G0 ➎ 4275 G JU640 ➎ 4858 T JU64W0 ➎ 5247 T JU640 ➎ 6801 A JU64G0 ➎ 4472 G JU640 ➎ 4920 T JU64W0 ➎ 5516 T JU640 ➎ 7007 A JU65G0 ➎ 7149 H JU650 ➎ 7637 H JU65W0 ➎ 8124 H JU650 ➎ 9749 Y JU65G0 ➎ 8321 J JU650 ➎ 8783 J JU65W0 ➎ 9400 J JU650 ➎ Y JU65G0 ➎ 8818 J JU650 ➎ 9280 J JU65W0 ➎ 9897 J JU650 ➎ Y1 Larger sizes available. ontact your Sprecher + Schuh representative. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AT JU610 becomes AT JU61R0. Price remains the same. ➌ Non-fusible combo-starter uses the L11 Non-Fusible isconnect. ➍ A Red and Yellow Handle may be selected instead of the standard Black handle. hange JU to LU in catalog number. ➎ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AT JU64G0 becomes AT9-116-E- - -JU64G0. See page 104 for price adder. 66 iscount Schedule B7

67 Through-the-door Operator ombination Starters - Reversing Non-Fusible isconnect - Series AUT Series AUT7 & AUT9 with Non-Fusible isconnect ➌➍ aximum Horsepower Three Phase Type 1 isc General Size/ Purpose Amps Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AUT AUT AUT AUT JU61G JU Q JU61W Q JU W JU61G JU Q JU61W Q JU W JU61G JU Q JU61W Q JU W JU61G JU Q JU61W Q JU W1 7.5 ~ ~ JU61G JU Q JU61W Q JU W1 ~ JU62G JU Q JU62W Q JU W JU62G JU Q JU62W Q JU W JU62G JU Q JU62W Q JU W1 15 ~ ~ JU62G JU Q JU62W Q JU W1 ~ ~ JU63G E JU R JU63W R JU W2 15 ~ ~ ~ JU62G E JU Q JU62W Q JU W2 ~ JU63G E JU R JU63W R JU W JU63G E JU R JU63W R JU W JU63G E JU R JU63W R JU W2 ~ 30 ~ JU63G E JU R JU63W R JU W2 30 ~ 75 ~ JU64G F JU T JU64W T JU A JU64G0 ➎ 5623 H JU640 ➎ 6281 H JU64W0 ➎ 6616 H JU640 ➎ R/F Y JU64G0 ➎ 6523 H JU640 ➎ 7286 H JU64W0 ➎ 7675 H JU640 ➎ R/F Y JU64G0 ➎ 7118 J JU640 ➎ 7677 J JU64W0 ➎ 7975 J JU640 ➎ R/F Z JU65G0 ➎ J JU650 ➎ J JU65W0 ➎ J JU650 ➎ R/F Z JU65G0 ➎ J JU650 ➎ J JU65W0 ➎ J JU650 ➎ R/F Z JU65G0 ➎ J JU650 ➎ J JU65W0 ➎ J JU650 ➎ R/F Z1 Larger sizes available. ontact your Sprecher + Schuh representative. ombination Starters NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AUT JU610 becomes AUT JU61R0. Price remains the same. ➌ Non-fusible combo-starter uses the L11 Non-Fusible isconnect. ➍ A Red and Yellow Handle may be selected instead of the standard Black handle. hange JU to LU in catalog number. ➎ AUT9-116 AUT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AUT JU64G0 becomes AUT9-116-E- - -JU64G0. See page 104 for price adder. iscount Schedule B7 67

68 NEA Sized ombination Starters - Through the oor Operated Sprecher + Schuh s through-the-door operated combination starters represent an economical alternative to the classic flange-operated combo solution. t is designed to meet rigid UL/NE withstand specifications. Sprecher + Schuh has been building custom control panels with this design for years. Experience the durability of this product! ombination Starters NEA Smart and cost effective for any application AN7 NEA labeled contactor (A) Starting with the best At the heart of all Sprecher + Schuh NEA sized combination starters is the ATN7 line of motor starters. Each starter proudly displays the NEA size (00, 0, 1, 2, or 3) and HP at applied voltage. This line of starters is designed to meet rigid consultant specifications for NEA starters. Top line protection NEA labeled combination starters are equipped with Sprecher + Schuh s premium EP7 solid state overload relay standard. Unlike traditional overload relays that indirectly sense motor current through heater elements, EP7 solid state overload relays measure motor current directly through integrated current transformers and on board electronics. The electronics provide numerous advantages over electromechanical relays. Alternatively, the T7N Thermal Overload Relay may also be selected. Thermal agnetic olded ase ircuit Breaker (B) The through-the-door operated combo B is available to meet UL short circuit withstand specifications. An B prevents single phasing by simultaneously opening all three phases when a fault occurs in any one phase. An B can often be reset after the fault has been cleared. isconnect Switches The through-the-door operated combo is available with the L11 switch. A mechanical door interlock system prevents the door from being opened when the disconnect is closed, and conversely, prevents the disconnect from being closed when the door is open. Both functions can be defeated for test and maintenance purposes. Other safety features include padlock provisions and a high visibility operating handle. hoice of isconnect hoices for disconnect include: Thermal agnetic olded ase ircuit Breaker (B) L11 Fusible or Non-Fusible isconnect switch The L11 Switch disconnects have a quick make/quick break, non-teasing action. The L11 fusible switch is suitable for interrupting up to 100,000 amperes when class J fuses are used. All L11 disconnect switches conform to UL 98 standards. hoice of Enclosures Available enclosures include; Type 1 General Purpose Type 3R Raintight Type 12 usttight Type 4 Type 4X orrosion Resistant 68 iscount Schedule B8

69 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Thermal-agnetic ircuit Breaker (B)- Series ATN Series ATN7 with Thermal-agnetic ircuit Breaker NEA Size aximum Horsepower Three Phase B Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ ATN ATN ATN ATN /2 1-1/2 2 ~ TB15G TB TB15W TB V ~ TB15G TB TB15W TB V2 3 ~ ~ ~ TB20G TB TB20W TB V2 ~ ~ 7-1/2 10 ➌ TB20G TB TB20W TB V2 ~ 5 10 ~ TB30G TB TB30W TB V2 5 ~ ~ ~ TB35G TB TB35W TB V2 ~ 7-1/2 ~ ~ TB40G TB TB40W TB V2 7-1/2 ~ ~ ~ TB50G TB TB50W TB V2 ~ ~ ~ 15 ➌ TB35G TB TB35W TB V2 ombination Starters NEA ~ ~ ➌ TB40G TB TB40W TB V2 2 ~ ~ ➌ TB50G TB TB50W TB V2 10 ~ 25 ~ TB60G TB TB60W TB V2 ~ 15 ~ ~ TB80G TB TB80W TB V2 ~ ~ ~ 30 ➌ TB60G TB Q TB60W Q TB W2 3 ~ ~ ➌ TB80G TB Q TB80W Q TB W ➌ TB100G TB Q TB100W Q TB W ~ TB125G TB Q TB125W Q TB W2 This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number ATN TB400 becomes ATN TB40R0. Price remains the same. ➌ Applicable to 600Y/347V only. Refer to page 70 for 600V elta solution. iscount Schedule B8 69

70 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Thermal-agnetic ircuit Breaker (B)- Series ATN ombination Starters NEA Series ATN7 with Thermal-agnetic ircuit Breaker - 600V elta NEA Size aximum Horsepower Three Phase B Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ ATN ATN ATN ATN /2 1-1/ TBH15G TBH TBH15W TBH V TBH15G TBH TBH15W TBH V2 1 ~ ~ 7-1/ TBH20G TBH TBH20W TBH V2 2 3 ~ ~ ~ TBH35G TBH TBH35W TBH V2 ~ ~ TBH40G TBH TBH40W TBH V2 ~ ~ TBH50G TBH TBH50W TBH V2 ~ ~ ~ TBH60G TBH Q TBH60W Q TBH W2 ~ ~ TBH80G TBH Q TBH80W Q TBH W TBH100G TBH Q TBH100W Q TBH W2 Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number ATN TBH400 becomes ATN TBH40R0. Price remains the same. 70 iscount Schedule B8

71 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Thermal-agnetic ircuit Breaker (B)- Series ATN Series ATN7 208V A with Thermal-agnetic ircuit Breaker NEA Size ax HP 3-Phase ➊ Auxiliary ontacts per ontactor ➋ B Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 208V NO N atalog No. Price ➌ atalog No. Price ➌ ATN7-12-XA-1BB-TB15G17-L ATN7-12-XA-1BB-TB15R17-L O ATN7-12-XA-1B-TB15G17-L ATN7-12-XA-1B-TB15R17-L O ATN7-12-XA-1B-TB15G17-L ATN7-12-XA-1B-TB15R17-L O ATN7-12-XA-1B-TB15G17-L ATN7-12-XA-1B-TB15R17-L O ATN7-12-XA-1B-TB15G17-L ATN7-12-XA-1B-TB15R17-L O ATN7-16-XA-1B-TB15G17-L ATN7-16-XA-1B-TB15R17-L O ATN7-16-XA-1B-TB20G17-L ATN7-16-XA-1B-TB20R17-L O ATN7-37-XA-1E-TB35G17-L ATN7-37-XA-1E-TB35R17-L O ATN7-37-XA-1E-TB50G17-L ATN7-37-XA-1E-TB50R17-L O ATN7-43-XA-1F-TB60G17-L ATN7-43-XA-1F-TB60R17-L O ATN7-85-XA-EGE-TB100G17-L ATN7-85-XA-EGE-TB100R17-L O ATN7-85-XA-EGE-TB125G17-L ATN7-85-XA-EGE-TB125R17-L O ATN7-85-XA-EGE-TB125G17-L ATN7-85-XA-EGE-TB125R17-L O Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T Reset pushbutton UL V class thermalmagnetic molded case circuit breaker ombination Starters NEA Series ATN7 230V A with Thermal-agnetic ircuit Breaker NEA Size ax HP 3-Phase ➍ Auxiliary ontacts per ontactor ➋ B Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 230V NO N atalog No. Price ➌ atalog No. Price ➌ ATN7-12-XB-1BB-TB15G17-L ATN7-12-XB-1BB-TB15R17-L O ATN7-12-XB-1B-TB15G17-L ATN7-12-XB-1B-TB15R17-L O ATN7-12-XB-1B-TB15G17-L ATN7-12-XB-1B-TB15R17-L O ATN7-12-XB-1B-TB15G17-L ATN7-12-XB-1B-TB15R17-L O ATN7-12-XB-1B-TB15G17-L ATN7-12-XB-1B-TB15R17-L O ATN7-16-XB-1B-TB15G17-L ATN7-16-XB-1B-TB15R17-L O ATN7-16-XB-1B-TB15G17-L ATN7-16-XB-1B-TB15R17-L O ATN7-37-XB-1E-TB30G17-L ATN7-37-XB-1E-TB30R17-L O ATN7-37-XB-1E-TB40G17-L ATN7-37-XB-1E-TB40R17-L O ATN7-43-XB-1F-TB60G17-L ATN7-43-XB-1F-TB60R17-L O ATN7-43-XB-1F-TB80G17-L ATN7-43-XB-1F-TB80R17-L O ATN7-85-XB-EGE-TB100G17-L ATN7-85-XB-EGE-TB100R17-L O ATN7-85-XB-EGE-TB125G17-L ATN7-85-XB-EGE-TB125R17-L O ATN7-85-XB-EGE-TB150G17-L ATN7-85-XB-EGE-TB150R17-L O This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 208V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ imensional information starts on page 122. ➍ HP and NEA size selection shown for 230V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. iscount Schedule B8 71

72 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Thermal-agnetic ircuit Breaker (B)- Series ATN ombination Starters NEA Series ATN7 460V A with Thermal-agnetic ircuit Breaker NEA Size ax HP 3-Phase ➊ Auxiliary ontacts per ontactor ➋ B Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 460V NO N atalog No. Price ➌ atalog No. Price ➌ ATN7-12-X-1BB-TB15G17-L ATN7-12-X-1BB-TB15R17-L O ATN7-12-X-1B-TB15G17-L ATN7-12-X-1B-TB15R17-L O ATN7-12-X-1B-TB15G17-L ATN7-12-X-1B-TB15R17-L O ATN7-12-X-1B-TB15G17-L ATN7-12-X-1B-TB15R17-L O ATN7-12-X-1B-TB15G17-L ATN7-12-X-1B-TB15R17-L O ATN7-12-X-1B-TB15G17-L ATN7-12-X-1B-TB15R17-L O ATN7-16-X-1B-TB15G17-L ATN7-16-X-1B-TB15R17-L O ATN7-16-X-1B-TB15G17-L ATN7-16-X-1B-TB15R17-L O ATN7-37-X-1E-TB20G17-L ATN7-37-X-1E-TB20R17-L O ATN7-37-X-1E-TB30G17-L ATN7-37-X-1E-TB30R17-L O ATN7-43-X-1F-TB40G17-L ATN7-43-X-1F-TB40R17-L O ATN7-43-X-1F-TB50G17-L ATN7-43-X-1F-TB50R17-L O ATN7-43-X-1F-TB60G17-L ATN7-43-X-1F-TB60R17-L O ATN7-85-X-EGE-TB80G17-L ATN7-85-X-EGE-TB80R17-L O ATN7-85-X-EGE-TB100G17-L ATN7-85-X-EGE-TB100R17-L O ATN7-85-X-EGE-TB125G17-L ATN7-85-X-EGE-TB125R17-L O Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T Reset pushbutton UL V class thermalmagnetic molded case circuit breaker This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 460V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ imensional information starts on page iscount Schedule B8

73 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Thermal-agnetic ircuit Breaker (B)- Series ATN Series ATN7 575V A with Thermal-agnetic ircuit Breaker NEA Size ax HP 3-Phase ➊ Auxiliary ontacts per ontactor ➋ B Amps Type 1 etallic General Purpose (except TBH) Type 3R etallic Outdoor Raintight 575V NO N atalog No. Price ➌ atalog No. Price ➌ ATN7-12-X-1BB-TBH15G17-L ATN7-12-X-1BB-TBH15R17-L O ATN7-12-X-1B-TBH15G17-L ATN7-12-X-1B-TBH15R17-L O ATN7-12-X-1B-TBH15G17-L ATN7-12-X-1B-TBH15R17-L O ATN7-12-X-1B-TBH15G17-L ATN7-12-X-1B-TBH15R17-L O ATN7-12-X-1B-TBH15G17-L ATN7-12-X-1B-TBH15R17-L O ATN7-16-X-1B-TBH15G17-L ATN7-16-X-1B-TBH15R17-L O ATN7-16-X-1B-TBH15G17-L ATN7-16-X-1B-TBH15R17-L O 7.5 ➍ ATN7-37-X-1E-TB20G17-L ATN7-37-X-1E-TB20R17-L O 10 ➍ ATN7-37-X-1F-TB20G17-L ATN7-37-X-1E-TB20R17-L O ATN7-37-X-1E-TBH20G17-L ATN7-37-X-1E-TBH20R17-L O ATN7-37-X-1F-TBH20G17-L ATN7-37-X-1F-TBH20R17-L O 15 ➍ ATN7-43-X-1F-TB35G17-L ATN7-43-X-1F-TB35R17-L O 20 ➍ ATN7-43-X-1F-TB40G17-L ATN7-43-X-1F-TB40R17-L O 25 ➍ ATN7-43-X-1F-TB50G17-L ATN7-43-X-1F-TB50R17-L O ATN7-43-X-1F-TBH35G17-L ATN7-43-X-1F-TBH35R17-L O ATN7-43-X-1F-TBH40G17-L ATN7-43-X-1F-TBH40R17-L O ATN7-43-X-1F-TBH50G17-L ATN7-43-X-1F-TBH50R17-L O 30 ➍ ATN7-85-X-EGE-TB60G17-L ATN7-85-X-EGE-TB60R17-L O 40 ➍ ATN7-85-X-EGE-TB80G17-L ATN7-85-X-EGE-TB80R17-L O 50 ➍ ATN7-85-X-EGE-TB100G17-L ATN7-85-X-EGE-TB100R17-L O ATN7-85-X-EGE-TBH60G17-L ATN7-85-X-EGE-TBH60R17-L O ATN7-85-X-EGE-TBH80G17-L ATN7-85-X-EGE-TBH80R17-L O ATN7-85-X-EGE-TBH100G17-L ATN7-85-X-EGE-TBH100R17-L O Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T Reset pushbutton UL V class thermalmagnetic molded case circuit breaker ombination Starters NEA This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 575V ratings only. ontact your Sprecher + Schuh representative for other voltage applications. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ imensional information starts on page 122. ➍ Applicable to 600Y/347V only. iscount Schedule B8 73

74 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Fusible isconnect - Series ATN ombination Starters NEA Series ATN7 with Fusible isconnect (J-Type) ➌➍ NEA Size aximum Horsepower Three Phase Fuse lip Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ ATN ATN ATN ATN /2 1-1/ JF61G JF JF61W Q JF V JF61G JF JF61W Q JF V JF61G JF JF61W Q JF V1 7-1/2 7-1/2 ~ ~ JF62G JF JF62W Q JF V1 ~ ~ ~ JF61G JF JF61W Q JF V JF62G JF JF62W Q JF V1 ~ 15 ~ ~ JF63G JF Q JF63W Q JF W1 ~ ~ JF62G JF Q JF62W Q JF W JF63G JF Q JF63W Q JF W ~ ~ JF64G G JF T JF64W T JF X1 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number ATN JF610 becomes ATN JF61R0. Price remains the same. ➌ Fusible combo starter uses the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➍ A Red and Yellow Handle may be selected instead of the standard Black handle. hange "JF" to "LF" in catalog number. 74 iscount Schedule B8

75 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Fusible isconnect - Series ATN Series ATN7 208V A with Fusible isconnect (J-Type) ➌➍ NEA Size ax HP 3-Phase ➊ Auxiliary ontacts per ontactor ➋ Fuse lip Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 208V NO N atalog No. Price ➏ atalog No. Price ➏ ATN7-12-XA-1BB-JF61G17-L ATN7-12-XA-1BB-JF61R17-L O ATN7-12-XA-1B-JF61G17-L ATN7-12-XA-1B-JF61R17-L O ATN7-12-XA-1B-JF61G17-L ATN7-12-XA-1B-JF61R17-L O ATN7-12-XA-1B-JF61G17-L ATN7-12-XA-1B-JF61R17-L O ATN7-12-XA-1B-JF61G17-L ATN7-12-XA-1B-JF61R17-L O ATN7-16-XA-1B-JF61G17-L ATN7-16-XA-1B-JF61R17-L O ATN7-16-XA-1B-JF61G17-L ATN7-16-XA-1B-JF61R17-L O ATN7-37-XA-1E-JF61G17-L ATN7-37-XA-1E-JF61R17-L O ATN7-37-XA-1E-JF62G17-L ATN7-37-XA-1E-JF62R17-L O ATN7-43-XA-1F-JF62G17-L ATN7-43-XA-1F-JF62R17-L O ATN7-85-XA-EGE-JF63G17-L ATN7-85-XA-EGE-JF63R17-L O ATN7-85-XA-EGE-JF63G17-L ATN7-85-XA-EGE-JF63R17-L O ATN7-85-XA-EGE-JF64G17-L G ATN7-85-XA-EGE-JF64R17-L T Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T UL98 fusible L11 disconnect Reset pushbutton ombination Starters NEA Series ATN7 230V A with Fusible isconnect (J-Type) ➌➍ NEA Size ax HP 3-Phase ➎ Auxiliary ontacts per ontactor ➋ Fuse lip Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 230V NO N atalog No. Price ➏ atalog No. Price ➏ ATN7-12-XB-1BB-JF61G17-L ATN7-12-XB-1BB-JF61R17-L O ATN7-12-XB-1B-JF61G17-L ATN7-12-XB-1B-JF61R17-L O ATN7-12-XB-1B-JF61G17-L ATN7-12-XB-1B-JF61R17-L O ATN7-12-XB-1B-JF61G17-L ATN7-12-XB-1B-JF61R17-L O ATN7-12-XB-1B-JF61G17-L ATN7-12-XB-1B-JF61R17-L O ATN7-16-XB-1B-JF61G17-L ATN7-16-XB-1B-JF61R17-L O ATN7-16-XB-1B-JF61G17-L ATN7-16-XB-1B-JF61R17-L O ATN7-37-XB-1E-JF61G17-L ATN7-37-XB-1E-JF61R17-L O ATN7-37-XB-1E-JF62G17-L ATN7-37-XB-1E-JF62R17-L O ATN7-43-XB-1F-JF62G17-L ATN7-43-XB-1F-JF62R17-L O ATN7-43-XB-1F-JF63G17-L ATN7-43-XB-1F-JF63R17-L O ATN7-85-XB-EGE-JF63G17-L ATN7-85-XB-EGE-JF63R17-L O ATN7-85-XB-EGE-JF63G17-L ATN7-85-XB-EGE-JF63R17-L O ATN7-85-XB-EGE-JF64G17-L G ATN7-85-XB-EGE-JF64R17-L T Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T UL98 fusible L11 disconnect Reset pushbutton This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 208V ratings only. ontact your Sprecher + Schuh representative for other voltage application. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ Fusible combo starter uses the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➍ A Red and Yellow Handle may be selected instead of the standard Black handle. hange JF to LF in catalog number. ➎ HP and NEA size selection shown for 230V ratings only. ontact your Sprecher + Schuh representative for other voltage application. ➏ imensional information starts on page 122. iscount Schedule B8 75

76 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Fusible isconnect - Series ATN Series ATN7 460V A with Fusible isconnect (J-Type) ➌➍ ombination Starters NEA NEA Size ax HP 3-Phase ➊ Auxiliary ontacts per ontactor ➋ Fuse lip Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 460V NO N atalog No. Price ➏ atalog No. Price ➏ ATN7-12-X-1BB-JF61G17-L ATN7-12-X-1BB-JF61R17-L O ATN7-12-X-1B-JF61G17-L ATN7-12-X-1B-JF61R17-L O ATN7-12-X-1B-JF61G17-L ATN7-12-X-1B-JF61R17-L O ATN7-12-X-1B-JF61G17-L ATN7-12-X-1B-JF61R17-L O ATN7-12-X-1B-JF61G17-L ATN7-12-X-1B-JF61R17-L O ATN7-12-X-1B-JF61G17-L ATN7-12-X-1B-JF61R17-L O ATN7-16-X-1B-JF61G17-L ATN7-16-X-1B-JF61R17-L O ATN7-16-X-1B-JF61G17-L ATN7-16-X-1B-JF61R17-L O ATN7-37-X-1E-JF61G17-L ATN7-37-X-1E-JF61R17-L O ATN7-37-X-1E-JF61G17-L ATN7-37-X-1E-JF61R17-L O ATN7-43-X-1F-JF62G17-L ATN7-43-X-1F-JF62R17-L O ATN7-43-X-1F-JF62G17-L ATN7-43-X-1F-JF62R17-L O ATN7-43-X-1F-JF62G17-L ATN7-43-X-1F-JF62R17-L O ATN7-85-X-EGE-JF62G17-L ATN7-85-X-EGE-JF62R17-L O ATN7-85-X-EGE-JF63G17-L ATN7-85-X-EGE-JF63R17-L O ATN7-85-X-EGE-JF63G17-L ATN7-85-X-EGE-JF63R17-L O Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T UL98 fusible L11 disconnect Reset pushbutton Series ATN7 575V A with Fusible isconnect (J-Type) ➌➍ NEA Size ax HP 3-Phase ➎ Auxiliary ontacts per ontactor ➋ Fuse lip Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 575V NO N atalog No. Price ➏ atalog No. Price ➏ ATN7-12-X-1BB-JF61G17-L ATN7-12-X-1BB-JF61R17-L O ATN7-12-X-1B-JF61G17-L ATN7-12-X-1B-JF61R17-L O ATN7-12-X-1B-JF61G17-L ATN7-12-X-1B-JF61R17-L O ATN7-12-X-1B-JF61G17-L ATN7-12-X-1B-JF61R17-L O ATN7-12-X-1B-JF61G17-L ATN7-12-X-1B-JF61R17-L O ATN7-16-X-1B-JF61G17-L ATN7-16-X-1B-JF61R17-L O ATN7-16-X-1B-JF61G17-L ATN7-16-X-1B-JF61R17-L O ATN7-37-X-1E-JF61G17-L ATN7-37-X-1E-JF61R17-L O ATN7-37-X-1E-JF61G17-L ATN7-37-X-1E-JF61R17-L O ATN7-43-X-1F-JF61G17-L ATN7-43-X-1F-JF61R17-L O ATN7-43-X-1F-JF62G17-L ATN7-43-X-1F-JF62R17-L O ATN7-43-X-1F-JF62G17-L ATN7-43-X-1F-JF62R17-L O ATN7-85-X-EGE-JF62G17-L ATN7-85-X-EGE-JF62R17-L O ATN7-85-X-EGE-JF62G17-L ATN7-85-X-EGE-JF62R17-L O ATN7-85-X-EGE-JF63G17-L ATN7-85-X-EGE-JF63R17-L O Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T UL98 fusible L11 disconnect Reset pushbutton This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 460V ratings only. ontact your Sprecher + Schuh representative for other voltage application. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ Fusible combo starter uses the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➍ A Red and Yellow Handle may be selected instead of the standard Black handle. hange JF to LF in catalog number. ➎ HP and NEA size selection shown for 575V ratings only. ontact your Sprecher + Schuh representative for other voltage application. ➏ imensional information starts on page iscount Schedule B8

77 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Non-Fusible isconnect - Series ATN Series ATN7 with Non-Fusible isconnect ➌➍ ombination Starters NEA NEA Size aximum Horsepower Three Phase isc Size/Amps Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ ATN ATN ATN ATN /2 1-1/ JU61G JU JU61W Q JU V JU61G JU JU61W Q JU V / JU61G JU JU61W Q JU V1 7-1/2 ~ ~ ~ JU62G JU JU62W Q JU V1 ~ ~ JU61G JU JU61W Q JU V JU62G JU JU62W Q JU V1 15 ~ JU62G JU Q JU62W Q JU W JU63G JU Q JU63W Q JU W2 NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. This item is available in the ORANGE E PRESS 3-day shipping program Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number ATN JU610 becomes ATN JU61R0. Price remains the same. ➌ Non-fusible combo-starter uses the L11 Non-Fusible isconnect. ➍ A Red and Yellow Handle may be selected instead of the standard Black handle. hange JU to LU in catalog number. iscount Schedule B8 77

78 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Non-Fusible isconnect - Series ATN ombination Starters NEA Series A with Non-Fusible isconnect ➌➍ NEA Size ax HP 3-Phase ➊ Auxiliary ontacts per ontactor ➋ isc Size/ Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 208V NO N atalog No. Price ➏ atalog No. Price ➏ ATN7-12-XA-1BB-JU61G17-L ATN7-12-XA-1BB-JU61R17-L O ATN7-12-XA-1B-JU61G17-L ATN7-12-XA-1B-JU61R17-L O ATN7-12-XA-1B-JU61G17-L ATN7-12-XA-1B-JU61R17-L O ATN7-12-XA-1B-JU61G17-L ATN7-12-XA-1B-JU61R17-L O ATN7-12-XA-1B-JU61G17-L ATN7-12-XA-1B-JU61R17-L O ATN7-16-XA-1B-JU61G17-L ATN7-16-XA-1B-JU61R17-L O ATN7-16-XA-1B-JU61G17-L ATN7-16-XA-1B-JU61R17-L O ATN7-37-XA-1E-JU61G17-L ATN7-37-XA-1E-JU61R17-L O ATN7-37-XA-1E-JU61G17-L ATN7-37-XA-1E-JU61R17-L O ATN7-43-XA-1F-JU62G17-L ATN7-43-XA-1F-JU62R17-L O ATN7-85-XA-EGE-JU62G17-L ATN7-85-XA-EGE-JU62R17-L O ATN7-85-XA-EGE-JU63G17-L ATN7-85-XA-EGE-JU63R17-L O ATN7-85-XA-EGE-JU63G17-L ATN7-85-XA-EGE-JU63R17-L O Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T UL98 non-fusible L11 disconnect switch Reset pushbutton Series A with Non-Fusible isconnect ➌➍ NEA Size ax HP 3-Phase ➎ Auxiliary ontacts per ontactor ➋ isc Size/ Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 230V NO N atalog No. Price ➏ atalog No. Price ➏ ATN7-12-XB-1BB-JU61G17-L ATN7-12-XB-1BB-JU61R17-L O ATN7-12-XB-1B-JU61G17-L ATN7-12-XB-1B-JU61R17-L O ATN7-12-XB-1B-JU61G17-L ATN7-12-XB-1B-JU61R17-L O ATN7-12-XB-1B-JU61G17-L ATN7-12-XB-1B-JU61R17-L O ATN7-12-XB-1B-JU61G17-L ATN7-12-XB-1B-JU61R17-L O ATN7-16-XB-1B-JU61G17-L ATN7-16-XB-1B-JU61R17-L O ATN7-16-XB-1B-JU61G17-L ATN7-16-XB-1B-JU61R17-L O ATN7-37-XB-1E-JU61G17-L ATN7-37-XB-1E-JU61R17-L O ATN7-37-XB-1E-JU61G17-L ATN7-37-XB-1E-JU61R17-L O ATN7-43-XB-1F-JU62G17-L ATN7-43-XB-1F-JU62R17-L O ATN7-43-XB-1F-JU62G17-L ATN7-43-XB-1F-JU62R17-L O ATN7-85-XB-EGE-JU63G17-L ATN7-85-XB-EGE-JU63R17-L O ATN7-85-XB-EGE-JU63G17-L ATN7-85-XB-EGE-JU63R17-L O ATN7-85-XB-EGE-JU63G17-L ATN7-85-XB-EGE-JU63R17-L O Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T UL98 non-fusible L11 disconnect switch Reset pushbutton This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 208V ratings only. ontact your Sprecher + Schuh representative for other voltage application. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ Fusible combo starter uses the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➍ A Red and Yellow Handle may be selected instead of the standard Black handle. hange JF to LF in catalog number. ➎ HP and NEA size selection shown for 230V ratings only. ontact your Sprecher + Schuh representative for other voltage application. ➏ imensional information starts on page iscount Schedule B8

79 NEA Sized Through-the-door Operator ombination Starters Non-Reversing Non-Fusible isconnect - Series ATN Series A with Non-Fusible isconnect ➌➍ NEA Size ax HP 3-Phase ➊ Auxiliary ontacts per ontactor ➋ isc Size/ Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 460V NO N atalog No. Price ➏ atalog No. Price ➏ ATN7-12-X-1BB-JU61G17-L ATN7-12-X-1BB-JU61R17-L O ATN7-12-X-1B-JU61G17-L ATN7-12-X-1B-JU61R17-L O ATN7-12-X-1B-JU61G17-L ATN7-12-X-1B-JU61R17-L O ATN7-12-X-1B-JU61G17-L ATN7-12-X-1B-JU61R17-L O ATN7-12-X-1B-JU61G17-L ATN7-12-X-1B-JU61R17-L O ATN7-12-X-1B-JU61G17-L ATN7-12-X-1B-JU61R17-L O ATN7-16-X-1B-JU61G17-L ATN7-16-X-1B-JU61R17-L O ATN7-16-X-1B-JU61G17-L ATN7-16-X-1B-JU61R17-L O ATN7-37-X-1E-JU61G17-L ATN7-37-X-1E-JU61R17-L O ATN7-37-X-1E-JU61G17-L ATN7-37-X-1E-JU61R17-L O ATN7-43-X-1F-JU61G17-L ATN7-43-X-1F-JU61R17-L O ATN7-43-X-1F-JU62G17-L ATN7-43-X-1F-JU62R17-L O ATN7-43-X-1F-JU62G17-L ATN7-43-X-1F-JU62R17-L O ATN7-85-X-EGE-JU62G17-L ATN7-85-X-EGE-JU62R17-L O ATN7-85-X-EGE-JU63G17-L ATN7-85-X-EGE-JU63R17-L O ATN7-85-X-EGE-JU63G17-L ATN7-85-X-EGE-JU63R17-L O Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T UL98 non-fusible L11 disconnect switch Reset pushbutton ombination Starters NEA Series A with Non-Fusible isconnect ➌➍ NEA Size ax HP 3-Phase ➎ Auxiliary ontacts per ontactor ➋ isc Size/ Amps Type 1 etallic General Purpose Type 3R etallic Outdoor Raintight 575V NO N atalog No. Price ➏ atalog No. Price ➏ ATN7-12-X-1BB-JU61G17-L ATN7-12-X-1BB-JU61R17-L O ATN7-12-X-1B-JU61G17-L ATN7-12-X-1B-JU61R17-L O ATN7-12-X-1B-JU61G17-L ATN7-12-X-1B-JU61R17-L O ATN7-12-X-1B-JU61G17-L ATN7-12-X-1B-JU61R17-L O ATN7-12-X-1B-JU61G17-L ATN7-12-X-1B-JU61R17-L O ATN7-16-X-1B-JU61G17-L ATN7-16-X-1B-JU61R17-L O ATN7-16-X-1B-JU61G17-L ATN7-16-X-1B-JU61R17-L O ATN7-37-X-1E-JU61G17-L ATN7-37-X-1E-JU61R17-L O ATN7-37-X-1E-JU61G17-L ATN7-37-X-1E-JU61R17-L O ATN7-43-X-1F-JU61G17-L ATN7-43-X-1F-JU61R17-L O ATN7-43-X-1F-JU61G17-L ATN7-43-X-1F-JU61R17-L O ATN7-43-X-1F-JU62G17-L ATN7-43-X-1F-JU62R17-L O ATN7-85-X-EGE-JU62G17-L ATN7-85-X-EGE-JU62R17-L O ATN7-85-X-EGE-JU62G17-L ATN7-85-X-EGE-JU62R17-L O ATN7-85-X-EGE-JU63G17-L ATN7-85-X-EGE-JU63R17-L O Full Voltage Non-Reversing (FVNR) Features include: NEA-sized AN7 contactor Three-Phase EP7 Electronic Overload Relay ontrol ircuit Transformer Hand-Off-Auto (H-O-A) selector switch Red Run pilot light 2-NO and 1-N auxiliaries for customer use lass Fuse holder as fused primary of T UL98 non-fusible L11 disconnect switch Reset pushbutton This item is available in the ORANGE E PRESS 3-day shipping program ➊ HP and NEA size selection shown for 460V ratings only. ontact your Sprecher + Schuh representative for other voltage application. ➋ ontactors are equipped with number and type of auxiliaries indicated. See page 108 to order additional or different auxiliary contacts. ➌ Fusible combo starter uses the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➍ A Red and Yellow Handle may be selected instead of the standard Black handle. hange JF to LF in catalog number. ➎ HP and NEA size selection shown for 575V ratings only. ontact your Sprecher + Schuh representative for other voltage application. ➏ imensional information starts on page 122. iscount Schedule B8 79

80 Explosion-proof Starters Sprecher + Schuh offers explosionproof starters for environments covered by the following classifications: NEA: Type 4/4X, 7B, 9EFG NE: lass, iv. 1 Groups B,, lass, iv. 1 Groups E, F, G lass UL: Standard 1203 Hazardous (lassified) Locations SA: Standard 22.2 No. 25 & 30 Safe and reliable starting in hazardous applications Explosion-Proof Starters SO9001, UL508 & UL1203 (NNNY) ATEX ertified Panel Shop Explosion-proof combination starters also comply with NEA Type 3, 3R, 4 & 4X. Optional ATEX certification is available in lass, Zone 1, AExd 1B, Exd 1B+H2, EXEx. NEA Type 4, 4X, 7, & 9 protection NEA Type 7 enclosures are designed to provide protection against an internal explosion when operated in a hazardous gas environment. NEA Type 9 enclosures protect from internal explosion in a hazardous dust environment. Both types must also prevent enclosed heat generating mechanisms from causing external surfaces to reach temperatures capable of igniting explosive gas-air mixtures in the surrounding atmosphere. Sprecher + Schuh explosion-proof starters meet all requirements of both classifications. nclusive with the selection of these explosion proof starters is a gasket inserted into the flange of the enclosure. This included gasket also gives the enclosures a NEA Type 4 watertight and NEA Type 4X corrosion resistance approval. Starting with the best Top line protection Explosion Proof starters are equipped with Sprecher + Schuh s EP7 solid state overload relay standard. Unlike traditional overload relays that indirectly sense motor current through heater elements, EP7 solid state overload relays measure motor current directly through integrated current transformers and on board electronics. The electronics provide numerous advantages over electromechanical relays. ombination starters for protection and convenience Explosion-proof combination starters can include either a UL489 approved Thermal agnetic ircuit Breaker (B) or non-fusible disconnect. The B utilizes the instantaneous trip ability of a magnetic breaker for short circuit currents combined with the overload tolerance of thermal circuit breakers for normal starting demands. An B can also be quickly reset after the fault has been cleared. A molded case switch (S) is used in applications requiring only a nonfused disconnect. Explosion Proof motor control panel mounted directly to motor and pump frame. At the heart of all explosion-proof starters is Sprecher + Schuh s AT7 and AT9 line of motor starters. These starters are compact and offer intermediate sizes to better match specific motor requirements. This equates to generous wiring space and less wasted horsepower capacity. 80

81 NEA Type 4/4X/7/9 Explosion Proof Starters Series AT Series AT7 & AT9 ➋ aximum Horsepower Without Short B With Thermal agnetic With Non Fusible Three Phase ircuit Protection Amps ircuit Breaker (B) isconnect 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ ➌ AT E A7 15 AT TB15EO 4663 E AT E A7 15 AT TBH15EO 4808 E ➌ AT E A7 20 AT TB20EO 4663 E AT E A7 20 AT TBH20EO 4808 E7 ~ 5 10 ~ AT E A7 30 AT TB30EO 4663 E7 5 ~ ~ 15 ➌ AT E A7 35 AT TB35EO 4663 E7 5 ~ ~ 15 AT E A7 35 AT TBH35EO 4808 E7 ~ AT E A7 40 AT TB40EO 4663 E7 ~ AT E A7 40 AT TBH40EO 4808 E ➌ AT E A7 50 AT TB50EO 4663 E7 7.5 ~ AT E A7 50 AT TBH50EO 4808 E ➌ AT E A7 50 AT TB50EO 4865 E ~ 30 AT E A7 50 AT TBH50EO 5011 E7 ~ ~ 30 ~ AT E A7 70 AT TB70EO 4967 E7 ~ 15 ~ ~ AT E A7 80 AT TB80EO 4967 E ➌ AT E A7 80 AT TB80EO 5017 E AT E A7 80 AT TBH80EO 5163 E7 ~ ~ ~ 40 ➌ AT E A7 80 AT TB80EO 5069 F7 ~ ~ ~ 40 AT E A7 80 AT TBH80EO 5214 F ➌ AT E A7 100 AT TB100EO 5069 F AT E A7 100 AT TBH100EO 5214 F ➌ AT E A7 125 AT TB125EO 5170 F AT E A7 125 AT TBH125EO 5315 F ~ AT E A7 125 AT TB125EO 5271 F7 ~ ~ ~ 75 ➌➍ AT E A7 150 AT TB150EO 5661 F7 ~ ~ ~ 75 ➍ AT E A7 150 AT TBH150EO 5809 F7 30 ➍ ~ 75 ➍ ~ AT E A7 175 AT TB175EO 5661 F7 30 ~ 75 ~ AT E0 ➎ 5235 B7 175 AT TB175E0 ➎ G7 ~ 40 ~ 100 ➌ AT E0 ➎ 5235 B7 200 AT TB200E0 ➎ G7 40 ~ ➌ AT E0 ➎ 6073 B7 225 AT TB225E0 ➎ G7 ~ 50 ~ ~ AT E0 ➎ 6073 B7 250 AT TB250E0 ➎ G AT E0 ➎ AT TB300E0 ➎ H AT E0 ➎ AT TB350E0 ➎ H7 75 ~ 175 ~ AT E0 ➎ AT TB400E0 ➎ H AT E0 ➎ AT TB450E0 ➎ H7 100 ~ ~ ~ AT E0 ➎ AT TB500E0 ➎ H7 ~ AT E0 ➎ AT TB600E0 ➎ H7 ~ ~ ~ 350 AT E0 ➎ AT TB600E0 ➎ H ~ AT E0 ➎ AT TB700E0 ➎ H ~ 400 AT9-400-E- - -E AT9-400-E- - -TB700E H7 ~ ~ 350 ~ AT9-400-E- - -E AT9-400-E- - -TB800E H7 150 ~ ~ ~ AT9-460-E- - -E AT9-460-E- - -TB800E H7 ~ AT9-460-E- - -E AT9-460-E- - -TB1000E H7 200 ~ ~ 600 AT9-580-E- - -E R/F 1000 AT9-580-E- - -TB1000E R/F ~ ~ AT9-580-E- - -E R/F 1200 AT9-580-E- - -TB1200E R/F Larger sizes and reversing starters available. ontact your Sprecher + Schuh representative. To order, select equivalent Thermal-agnetic ircuit Breaker catalog number from this chart. Specify on order, With molded case switch. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Explosion-Proof Starters Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ Enclosures have gaskets for outdoor use (Type 4). ➌ Applicable to 600Y/347V only. ➍ The short circuit and ka is relegated to the contactor s 10kA. ontact your Sprecher + Schuh representative for a higher ka. ➎ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AT TB175E0 becomes AT9-116-E- - -TB175E0. See page 104 for price adder. iscount Schedule B7 81

82 Accessories Field nstallable NEA Type 4/4X/7/9 Explosion Proof Pilot evice Kits Explosion-Proof Starters Pilot evice Kits NEA Type 4/4X/7/9 Applications (For use with Explosion Proof Enclosures) Kits escription START Pushbutton Green, Non-illuminated, momentary, with legend ➊➋ STOP Pushbutton Red, Non-illuminated, momentary, with legend ➊➋ UAL Pushbutton Non-illuminated, momentary OFF-ON Selector Switch Non-illuminated, maintained, with legend HAN-AUTO Selector Switch Non-illuminated, maintained, with legend HAN-OFF-AUTO Selector Switch Non-illuminated, maintained, with legend FW-OFF-REV Selector Switch Non-illuminated, maintained, with legend ontact Blocks included NO N atalog Number Price 1 0 XHPB-BT4-XNP XHPB-BT5-XNP XHPB-BT1A XHSS-1-BT4-XNP/OFF-ON XHSS-1-BT1A-XNP/HAN-AUTO XHSS-3-BT2-XNP/HAN-OFF-AUTO XHSS-3-BT2-XNP/FW-OFF-REV 277 RE EERGENY STOP Pushbutton Non-illuminated, maintained push-pull, with legend 1 1 XHPP-BT1A-XNP/ESTOP 577 echanical RESET Pushbutton 0 0 XRB 93 GUARE Pilot Light ➌ 120V incandescent, screw terminations Amber Blue lear Green Red White XLAT-GH XLBT-GH XLT-GH XLGT-GH XLRT-GH XLWT-GH 250 PUSHBUTTON LOKOUT - Accessory Padlock device to activate pushbutton ~ XHPL 147 OPERATOR PROTETVE BOOT Rubber push button cap Green Red XBG XBR 50 OPERATOR PROTETVE BOOT Rubber selector switch cap Black XBSB 50 OBNATON BREATHER/RAN ➍ nstall on top of enclosure for Breather nstall in bottom of enclosure for rain Stainless steel XBH2 76 ➊ Legend Plates are anodized aluminum with engraved letters on black background (XNP). ➋ STOP has red background. START has green background. ➌ One of the NPS hole locations on the A7 dimensional enclosure could create the need for a short pilot light. Refer to factory for details. ➍ Requires purchase of 2 pcs for application of both Breather and rain. 82 iscount Schedule B7 B6

83 ultispeed Starters Sprecher + Schuh multispeed starters can produce multiple constant speeds by specially arranging the windings of multispeed motors. otors with two separate windings or one reconnectable winding can be used. Versatile starters for any multispeed motor or application ustom 2-speed, 1-winding combination starter with control transformer and deceleration relay, mounted in a Type-1 enclosure All Sprecher + Schuh multispeed starters feature our AT7 and AT9 motor starters. These compact starters offer intermediate sizes to better match specific motor requirements. This equates to generous wiring space and less wasted horsepower capacity. Advanced EP7 solid state overload relays are used with starters. See Section B in this catalog for a full description of these excellent motor protection relays. hoose the right starter for your application ultispeed motors fall into three types, all with differing torque characteristics. Selecting the proper type depends on the connected load. onstant Torque motors deliver the same torque at each speed, and horsepower varies directly with the speed. Typical applications include reciprocating pumps, conveyors, mills and mixers. onstant Horsepower motors deliver the same horsepower at each speed and the torque varies inversely with the speed. Typical applications include machine tools such as drills, lathes, mills, punch presses and saws. Variable Torque (variable horsepower) motors deliver a torque that varies directly with the speed and the horsepower varies directly with the square of the speed. Typical applications include centrifugal pumps, fans and blowers. ontrol options The four common forms of control for multispeed starters are known as selective, compelling, progressive and decelerating. Standard multispeed starters are wired for selective control. The other control options are available as factory modifications. Selective ontrol permits starting the motor on any desired speed. To increase the speed of a running motor, press the desired speed button. To change to a lower speed, the STOP button must be pressed before selecting a new speed. ompelling ontrol requires that the motor always be started at the lowest speed. To reach higher speeds, the push buttons must be operated in the speed sequence. To change to a lower speed, the STOP button must be pressed before selecting a new speed. Progressive ontrol provides automatic, timed acceleration of the motor to the selected speed by energizing the windings progressively from the lowest to the desired speed. To change to a lower speed, the STOP button must be pressed before selecting a new speed. ecelerating ontrol provides automatic time delay to a lower speed. This type of control allows the motor to decelerate from a high speed before automatically restarting the motor in a lower speed. ecelerating ontrol prevents damage to the motor or machine when high inertia loads are switched to a lower speed. ontact your Sprecher + Schuh representative for more information. ulti-speed Starters 83

84 ultispeed Starters Series AZTT & AZHT ulti-speed Starters Two Separate Windings AZTT7/AZTT9 & AZHT7/AZHT9 ➌ aximum Horsepower Three Phase Open Type Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AZTT becomes AZTT R0. Price remains the same. ➌ All standard multispeed starters are wired for selective control. For compelling, progressive or automatic acceleration control, see Factory odifications. ➍ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AZTT G0 becomes AZTT E- - -G0. See page 104 for price adder. Type 4X orr Resist Non-metallic 200V 230V 460V 575V atalog No. Price atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ onstant or Variable Torque - AZTT ➌ AZTT AZTT AZTT AZTT AZTT / G O WO 889 N O 849 U / G O WO 930 N O 889 U G O WO 970 N O 930 U / G O WO 1051 N O 1011 U1 7 1/ G O WO 1197 O O 1156 U G O WO 1286 O O 1245 U G O WO 1697 O O 1658 U G O WO 1769 O O 1729 U G O 2021 O WO 2061 O O 2061 V G O 2158 O WO 2182 O O 2182 V G O 2320 O WO 2344 O O 2344 V G O 2436 O WO 2460 O O 2460 V ➍ G0 ➍ 4853 E ➍ 5344 R W0 ➍ 5427 R ➍ 5177 W ➍ G0 ➍ 5629 G ➍ 6199 T W0 ➍ 6295 T ➍ 6005 X1 onstant Horsepower - AZHT ➌ AZHT AZHT AZHT AZHT AZHT 1 1/2 1 1/ G O WO 889 N O 849 U / G O WO 930 N O 889 U / G O WO 970 N O 930 U G O WO 1051 N O 1011 U / G O WO 1197 O O 1156 U1 7 1/2 7 1/ G O WO 1286 O O 1245 U1 7 1/ G O WO 1697 O O 1658 U G O WO 1769 O O 1729 U G O 2021 O WO 2061 O O 2061 V G O 2158 O WO 2182 O O 2182 V G O 2320 O WO 2344 O O 2344 V G O 2436 O WO 2460 O O 2460 V1 ~ ➍ G0 ➍ 4843 E ➍ 5344 R W0 ➍ 5427 R ➍ 5177 W ➍ G0 ➍ 5618 G ➍ 6199 T W0 ➍ 6295 T ➍ 6005 X1 Larger sizes available. ontact your Sprecher + Schuh representative. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay for each speed Factory odifications available See page 104 See pages See pages iscount Schedule B7

85 ultispeed Starters Series AETT & AEHT One Reconnectable Winding AETT7/AETT9 & AEHT7/AEHT9 ➌ aximum Horsepower Three Phase Open Type Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orr Resist Non-metallic 200V 230V 460V 575V atalog No. Price atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ onstant or Variable Torque - AETT ➌ AETT AETT AETT AETT AETT / G O 1100 O WO 1115 O O 1277 V / G O 1212 O WO 1229 O O 1390 V G O 1277 O WO 1294 O O 1455 V / G O 1318 O WO 1342 O O 1504 V1 7 1/ G O 1536 O WO 1552 O O 1714 V G O 1697 O WO 1714 O O 1876 V G O 1940 O WO 1957 O O 2119 V G O 2048 O WO 2068 O O 2226 V G O 2668 O WO 2829 O O 2668 W G O 2829 Q WO 2991 Q O 2829 W G O 2991 Q WO 3153 Q O 2991 W G O 3107 Q WO 3269 Q O 3107 W ➍ G0 ➍ 5845 G ➍ 6262 T W0 ➍ 6722 T ➍ 8183 A ➍ G0 ➍ 6780 G ➍ 7264 T W0 ➍ 7798 T ➍ 9492 A2 onstant Horsepower - AEHT ➌ AEHT AEHT AEHT AEHT AEHT 1 1/2 1 1/ G O 1100 O WO 1115 O O 1277 V / G O 1212 O WO 1229 O O 1390 V / G O 1277 O WO 1294 O O 1455 V G O 1318 O WO 1342 O O 1504 V / G O 1536 O WO 1552 O O 1714 V1 7 1/2 7 1/ G O 1697 O WO 1714 O O 1870 V1 7 1/ G O 1940 O WO 1957 O O 2119 V G O 2048 O WO 2064 O O 2226 V G O 2668 O WO 2829 O O 2668 W G O 2829 Q WO 2991 Q O 2829 W G O 2991 Q WO 3153 Q O 2991 W G O 3107 Q WO 3269 Q O 3107 W1 ~ ➍ G0 ➍ 5845 G ➍ 6262 T W0 ➍ 6722 T ➍ 8183 A ➍ G0 ➍ 6780 G ➍ 7264 T W0 ➍ 7798 T ➍ 9492 A2 Larger sizes available. ontact your Sprecher + Schuh representative. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ulti-speed Starters Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AETT becomes AETT R0. Price remains the same. ➌ All standard multispeed starters are wired for selective control. For compelling, progressive or automatic acceleration control, see Factory odifications. ➍ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: AEHT G0 becomes AEHT9-116-E- - -G0. See page 104 for price adder. iscount Schedule B7 85

86 ultispeed Starters Series AEHT, AETT, AZHT & AZTT ombination ulti-speed Starter Options hart ➊ Price (Add to base multi-speed starter list price) ulti-speed Starters ircuit Breaker or isconnect Switch Thermal agnetic ircuit Breaker Non Fusible isconnect Fusible isconnect - 30 Amp Fusible isconnect - 60 Amp Fusible isconnect Amp Fusible isconnect Amp Enclosure Type (-E) (-E) Type Type 4/4X Type Type Type 4/4X Type Type ~ ~ ~ Type 4/4X ~ ~ ~ Type ~ ~ ~ Type 1 ~ ~ 858 ~ ~ Type 4/4X ~ ~ 1367 ~ ~ Type 12 ~ ~ 911 ~ ~ Type 1 ~ ~ ~ 1099 ~ Type 4/4X ~ ~ ~ 2144 ~ Type 12 ~ ~ ~ 1193 ~ Type 1 ~ ~ ~ Type 4/4X ~ ~ ~ Type 12 ~ ~ ~ ➊ Refer to pages 4-5 for information on modifying standard multispeed catalog number to combination type or contact Sprecher + Schuh Technical Support. 86 iscount Schedule B7

87 Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current of a motor is likely to exceed local power company restrictions, interfere with plant operations or where the load may be damaged by high starting torques. Starting with the best All Sprecher + Schuh reduced voltage starters feature our AT7 and AT9 line of motor starters. These compact starters offer intermediate sizes to better match specific motor requirements. This equates to generous wiring space and less wasted horsepower capacity. Our advanced EP7 solid state overload relays are used with starters. See Section B in this catalog for a full description of these excellent motor protection relays. hoosing the right reduced voltage method Autotransformer Starter At starting, three autotransformers (one for each phase) are automatically connected in series with the motor. The voltage at the motor is reduced to either 50%, 65% or 80% depending on which voltage tap was selected. After a timed interval, a contactor connects the motor across-the-line and shorts out the autotransformers. Factory standard autotransformers are rated for medium duty as defined by NEA. Part Winding Starter This type of starting requires that the motor winding be in two equal parts, and that at least six terminal leads be provided on the motor. At starting, the controller is arranged to connect one section of the winding to the supply lines. After a timed interval, a second contactor connects the other section of the motor winding to the supply lines, in parallel with the first. Wye-elta Starter This type of starting requires a special wye-delta motor. Both ends of the motor s three windings are brought out so they are accessible for reconnecting from wye to delta. At starting, the controller connects the motor in the wye configuration. After a timed interval, a second contactor connects the motor in a delta configuration. The reference chart below compares all three reduced voltage starting methods and contrasts them with across-theline starting. Reduced Voltage Starters Reduced Voltage omparison Table Type of Starter Starting haracteristics Line urrent otor Starting Torque Across-The-Line 100% 100% 100% Autotransformer 80% 65% 50% 64% 42% 25% 64% 42% 25% Part Winding 100% 65% 42% Advantages l Least expensive. l Simple to maintain. l Highest starting torque. l Readily available. l Lowest installation cost. l Provides highest torque per ampere of line current. l Three different taps on transformer permit adjustment of starting voltage. l Suitable for long starting periods. l losed transition starting. l Uses standard motor.. l Least expensive of all reduced voltage starters. l losed transition starting. l Small physical size. l ost dual voltage motors can be used. l Simple design. l Low installation cost. isadvantages l High starting inrush may exceed limits of local utility or electrical system. l Starting torque may be too high for the application. l Limited to smaller horsepower motors. l n lower horsepower, is the most expensive design. l Low power factor. l Large physical size. l High installation cost. l Poor torque efficiency l Unsuited for high inertia, long starting loads. l otor may not accelerate during start period. l Requires special motor design for voltages higher than 230 volts. Wye-elta 100% 33% 33% l Suitable for high inertia, long acceleration loads. l High torque efficiency. l deal for especially stringent inrush restrictions. l deal for frequent starts. l Requires special motor design. l Low starting torque. l Open transition (closed available). l omplex design. 87

88 Reduced Voltage Starters Autotransformer - Series AAT Autotransformer 10 HP to 125 HP (losed Transition - Type 1 General Purpose Enclosure) ➍ Reduced Voltage Starters aximum H.P Ø Volts Without Short ircuit Protection B Amps With Thermal agnetic ircuit Breaker (B) Fuse lip Amps With Fusible isconnect ➋➎ atalog No. Price ➊ atalog No. Price ➊ ➌ atalog No. Price ➊ AAT AAT AAT 200 BA G F 50 BA TB50G S 60 BA JF62G S 230 BB G F 50 BB TB50G S 60 BB JF62G S 200 A G F 100 A TB100G S 100 A JF63G S 230 B G F 80 B TB80G S 100 B JF63G S 200 A G F 125 A TB125G S 100 A JF63G S 230 B G F 100 B TB100G S 100 B JF63G S 200 EA G F 125 EA TB125G S 200 EA JF64G S 230 EB G F 125 EB TB125G S 100 EB JF63G S 460 E G F 50 E TB50G S 60 E JF62G S 200 FA G F 175 FA TB175G0 ➏ S 200 FA JF64G FB G F 125 FB TB125G S 200 FB JF64G S 460 F G F 70 F TB70G S 60 F JF62G S 575 F G F 50 F TBH50G S 60 F JF62G S 200 GA G0 ➐ H 225 GA TB225G0 ➐ J 200 GA JF64G0 ➐ J 230 GB G0 ➐ H 200 GB TB200G0 ➐ J 200 GB JF64G0 ➐ J 460 G G F 100 G TB100G S 100 G JF63G S 575 G G F 80 G TBH80G S 60 G JF62G S 200 HA G0 ➐ HA TB300G0 ➐ J 400 HA JF65G0 ➐ K3 230 HB G0 ➐ HB TB250G0 ➐ J 200 HB JF64G0 ➐ J 460 H G F 125 H TB125G S 100 H JF63G S 575 H G F 100 H TBH100G S 100 H JF63G S 200 JA G0 ➐ J 350 JA TB350G0 ➐ J 400 JA JF65G0 ➐ K3 230 JB G0 ➐ JB TB300G0 ➐ J 400 JB JF65G0 ➐ K3 460 J G F 125 J TB125G S 200 J JF64G S 575 J G F 125 J TBH125G S 100 J JF63G S 200 KA G0 ➐ J 400 KA TB400G0 ➐ K2 400 KA JF65G0 ➐ K2 230 KB G0 ➐ J 350 KB TB350G0 ➐ K2 400 KB JF65G0 ➐ K2 460 K G F 175 K TB175G0 ➏ S 200 K JF64G K G F 150 K TBH150G0 ➏ S 200 K JF64G LA G0 ➐ J2 500 LA TB500G0 ➐ K2 600 LA JF66G0 ➐ K2 230 LB G0 ➐ J 450 LB TB450G0 ➐ K2 400 LB JF65G0 ➐ K2 460 L G0 ➐ L TBH225G0 ➐ J 200 L JF64G0 ➐ J 575 L G0 ➐ H 200 L TBH200G0 ➐ J 200 L JF64G0 ➐ J 200 A G0 ➐ J2 700 A TB700G0 ➐ K2 600 A JF66G0 ➐ K2 230 B G0 ➐ J2 600 B TB600G0 ➐ K2 600 B JF66G0 ➐ K G0 ➐ TB300G0 ➐ J JF65G0 ➐ K G0 ➐ TBH225G0 ➐ J JF64G0 ➐ J Larger Horsepower ontinued On Next Page NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Non-fusible isconnect applications, replace the "JF" characters with "JU". Example: AATH JF63G0 becomes AATH JU63G0. ➌ Fuse clips sized for use with J -type fuses. ➍ Other enclosures available. ontact your Sprecher + Schuh Representative. ➎ A Red and Yellow Handle may be selected instead of the standard Gray and Black handle. hange JF to LF in catalog number. ➏ The short circuit and ka is relegated to the contactor s 10kA. ontact your Sprecher + Schuh representative for a higher ka. ➐ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. For example: AATGB G0 becomes AATGB9-116-E- - -G0. See page 104 for price adder. 88 iscount Schedule B7

89 Reduced Voltage Starters Autotransformer - Series AAT Autotransformer 150 HP to 1000 HP (losed Transition - Type 1 General Purpose Enclosure) ➍ aximum H.P. 3 Ø Volts Without Short ircuit Protection B Amps With Thermal agnetic ircuit Breaker (B) atalog No. Price ➊ atalog No. Price ➊ ➌ atalog No. Price ➊ AAT AAT AAT 200 NA9-460-E- - -G J2 800 NA9-460-E- - -TB800G R/F 800 NA9-460-E- - -JF67G ~ NB G0 ➏ J2 700 NB TB700G0 ➏ K2 600 NB JF66G0 ➏ K2 460 N G0 ➏ N TB350G0 ➏ J 400 N JF65G0 ➏ K3 575 N G0 ➏ N TB300G0 ➏ J 400 N JF65G0 ➏ K3 230 OB9-460-E- - -G0 R/F ~ 1000 OB9-460-E- - -TB1000G ~ 800 OB9-460-E- - -JF67G ~ O G0 ➏ J 450 O TB450G0 ➏ K2 400 O JF65G0 ➏ K2 575 O G0 ➏ J 350 O TB450G0 ➏ K2 400 O JF65G0 ➏ K3 230 PB9-580-E- - -G0 R/F ~ Refer to Factory R/F ~ Refer to Factory R/F ~ P G0 ➏ J2 600 P TB600G0 ➏ K2 600 P JF66G0 ➏ K2 575 P G0 ➏ J 450 P TB450G0 ➏ K2 400 P JF65G0 ➏ K2 230 QB9-750-E- - -G0 R/F ~ Refer to Factory R/F ~ Refer to Factory R/F ~ Q G0 ➏ J2 700 Q TB700G0 ➏ K2 600 Q JF66G0 ➏ K2 575 Q G0 ➏ J2 600 Q TB600G0 ➏ K2 600 Q JF66G0 ➏ K2 230 Refer to Factory R/F ~ Refer to Factory R/F ~ Refer to Factory R/F ~ R9-400-E- - -G J2 800 R9-400-E- - -TB800G RF 800 R9-400-E- - -JF67G ~ 575 R G0 ➏ J2 600 R TB600G0 ➏ K2 600 R JF66G0 ➏ K2 230 Refer to Factory R/F ~ Refer to Factory R/F ~ Refer to Factory R/F ~ S9-460-E- - -G ~ 1000 S9-460-E- - -TB1000G ~ 800 S9-460-E- - -JF67G ~ 575 S9-400-E- - -G J2 700 S9-400-E- - -TB700G K2 600 S9-400-E- - -JF66G ~ 230 Refer to Factory R/F ~ Refer to Factory R/F ~ T9-580-E- - -G ~ Refer to Factory R/F ~ 575 T9-460-E- - -G ~ 800 T9-460-E- - -TB800G ~ U9-580-E- - -G ~ Refer to Factory R/F ~ Refer to Factory 575 U9-460-E- - -G ~ 900 Refer to Factory R/F ~ U9-750-E- - -G ~ 575 U9-580-E- - -G ~ Refer to Factory R/F ~ Larger sizes available. ontact your Sprecher + Schuh representative. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. Fuse lip Amps With Fusible isconnect ➋➎ Reduced Voltage Starters Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Non-fusible isconnect applications, replace the "JF" characters with "JU". Example: AATN9-205-E- - -JF65G0 becomes AATN9-205-E- - -JU65G0. ➌ Fuse clips sized for use with J -type fuses up to 600A. Power fuses not supplied. ➍ Other enclosures available. ontact your Sprecher + Schuh Representative. ➎ A Red and Yellow Handle may be selected instead of the standard Gray and Black handle. hange JF to LF in catalog number. ➏ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. For example: AATN G0 becomes AATN9-190-E- - -G0. See page 104 for price adder. iscount Schedule B7 89

90 Reduced Voltage Starters Part Winding - Series APWT Reduced Voltage Starters Part Winding (Two Step) aximum Horsepower Three Phase Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resist Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ APWT APWT APWT APWT G O WO O 1981 U1 15 ~ G O WO O 2547 U G O WO O 2911 U G O WO O 2982 U G O 2425 O WO 3266 O O 3266 V G O 2587 O WO 3476 O O 3476 V G O 3314 O WO 4196 O O 4196 V G O 3489 O WO 4371 O O 4371 V G0 ➍ 5427 E ➍ 7097 R W0 ➍ 8333 R ➍ 8333 W G0 ➍ 6295 G ➍ 8233 T W0 ➍ 9666 T ➍ 9666 A G0 ➍ 8175 H ➍ 8918 H W0 ➍ H ➍ Y G0 ➍ H ➍ H W0 ➍ H ➍ Y G0 ➍ J ➍ J W0 ➍ J ➍ Z G0 ➍ J ➍ J W0 ➍ J ➍ Z1 Larger sizes available. ontact your Sprecher + Schuh representative. NOTE: atalog numbers and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying catalog numbers. ombination Part Winding Starter Options hart ➌ ircuit Breaker or isconnect Switch Thermal agnetic ircuit Breaker Non Fusible isconnect Fusible isconnect - 30 Amp Fusible isconnect - 60 Amp Fusible isconnect Amp Fusible isconnect Amp Fusible isconnect Amp Fusible isconnect Amp Price (Add to base Part Winding starter list price) 7-60 Enclosure (-E) (-E) 9-205(-E) Type (-E) 9-265(-E) Type Type 12/3R/4/4X Type Type 12/3R/4/4X Type ~ ~ ~ ~ Type 12/3R/4/4X 998 ~ ~ ~ ~ Type ~ ~ ~ Type 12/3R/4/4X ~ 1193 ~ ~ ~ Type 1 ~ ~ ~ Type 12/3R/4/4X ~ ~ ~ Type 1 ~ ~ ~ Type 12/3R/4/4X ~ ~ ~ Type 1 ~ ~ ~ Type 12/3R/4/4X ~ ~ ~ Type 1 ~ ~ ~ ~ 7256 Type 12/3R/4/4X ~ ~ ~ ~ (-E) ontact factory for pricing. Ordering nstructions Specify atalog Number Replace (Q) with oil ode ultiply otor FLA by 50%, Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". Price remains the same, dimensions may change. Example: APWT becomes APWT R0. ➌ Refer to pages 4-5 for information on modifying standard Part Winding catalog number to combination type or contact Sprecher + Schuh Technical Support. ➍ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. For example: AATN G0 becomes AATN9-190-E- - -G0. See page 104 for price adder. 90 iscount Schedule B7

91 Reduced Voltage Starters Wye elta - Series AYT Wye elta (Open Transition, 3-ontactor ➍) aximum Horsepower Three Phase Type 1 General Purpose Type 12 [Type 3R ➋] ndustrial usttight Type 4 Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ atalog No. Price ➊ AYT AYT AYT AYT G O 1496 O WO 1940 O O 1940 V G O 2182 O WO 2628 O O 2587 V G O 2385 O WO 2829 O O 2829 V G O 2492 O WO 2937 O O 2937 V G O 3702 Q WO 3517 Q O 3702 W G F O 3951 T WO 4446 T O 5659 X G F O 4285 T WO 4851 T O 5983 X G G T W T A G G T W T A G H H W H Y G W J Z G J J W J Z G J J W J Z G J J W J Z E- - -G ~ E ~ E- - -W ~ E ~ E- - -G ~ E ~ E- - -W ~ E ~ E- - -G ~ E ~ E- - -W ~ E ~ E- - -G ~ E ~ E- - -W ~ E ~ E- - -G ~ E ~ E- - -W ~ E ~ E- - -G ~ E ~ E- - -W ~ E ~ Larger sizes available. ontact your Sprecher + Schuh representative. Reduced Voltage Starters ombination Wye elta Starter Options hart ➌ ircuit Breaker or isconnect Switch Thermal agnetic ircuit Breaker Non Fusible isconnect Fusible isconnect - 30 Amp Fusible isconnect - 60 Amp Fusible isconnect Amp Fusible isconnect Amp Fusible isconnect Amp Fusible isconnect Amp Price (Add to base Part Winding starter list price) 9-305(-E) (-E) 9-370(-E) Enclosure (-E) 9-205(-E) E Type (-E) 9-265(-E) E Type Type 12/3R/4/4X Type Type 12/3R/4/4X Type ~ ~ ~ ~ ~ Type 12/3R/4/4X 911 ~ ~ ~ ~ ~ Type ~ ~ ~ ~ Type 12/3R/4/4X ~ ~ ~ ~ Type 1 ~ ~ ~ ~ Type 12/3R/4/4X ~ ~ ~ ~ Type 1 ~ ~ ~ ~ Type 12/3R/4/4X ~ ~ ~ ~ Type 1 ~ ~ ~ ~ Type 12/3R/4/4X ~ ~ ~ ~ Type 1 ~ ~ ~ ~ Type 12/3R/4/4X ~ ~ ~ ~ E E E E ontact factory for pricing. Ordering nstructions Specify atalog Number Replace (Q) with oil ode ultiply otor FLA by 58%, Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ For Type 3R outdoor applications, replace "" in catalog number with an "R". imensions may change. For example number AYT becomes AYT R0. Price remains the same. ➌ Refer to pages 4-5 for information on modifying standard Wye elta catalog number to combination type or contact Sprecher + Schuh Technical Support. ➍ For closed transition Wye elta applications, please contact factory. iscount Schedule B7 91

92 Simplex & uplex Pump Panels Pump ontrollers Pump control panels for outdoor irrigation and oil well applications Sprecher + Schuh pump control panels are specifically designed to meet ombination starter requirements in demanding outdoor environmental conditions. Typical applications include irrigation and waste water treatment as well as oil well and agricultural applications. Pump ontrollers from Sprecher + Schuh offer through-the-door operators and rugged Type 3R rain-proof metal or Type 4X non-metallic enclosures. These enclosures in some cases are somewhat smaller than previous models but still with adequate room to mount a mechanical timer and other customer supplied controls. Three models of Pump ontrollers Thermal-magnetic circuit breakers (B) instead of a motor circuit protector (P) to comply with short-circuit requirements from UL and NE. Heavy duty fusible or non-fusible L11 disconnect switches provide improved short-circuit protection when used with J fuses. Self-protected ombination ontrollers (Type E) KTA7 models which offer superior fuseless shortcircuit protection in a smaller more economical package (See page F111). Pump panels feature our A7 and A9 line of contactors which are UL Listed and sized to match all the available HP sizes of motors. Alternately, we can provide NEA Sized (AN7) contactors, which comply with all requirements by UL and are labeled with the applicable NEA (00, 0, 1, 2, or 3) size in our pump panels. Our B models and the L11 models utilize the EP7 solid state overload relay providing state-of-the-art overload and single-phase protection. See Section B in this catalog for a full description of these excellent motor protection relays. Our KTA7 model utilizes the high speed current limiting capabilities providing short-circuit protection, branch-circuit disconnect, and overload protection in one compact device. See Section F in this catalog for application details for these Type E ombos. Standard or ustomized Features Standard pump controllers are equipped with START pushbutton and H-O-A selector switch. The entire assembly is mounted in an outdoor enclosure with provision for mounting on a pole or a wall and top conduit provisions. Oversized enclosures can be provided for each of the pump controllers to accommodate extra equipment. Our factory modification section lists many of the options that are commonly requested. A customized pump controller quotation including door-in-door (dead-front) models, reduced voltage models and models with customized control diagrams can be provided on demand by contacting your Sprecher + Schuh representative. 92

93 Through-the-door Operator Pump Panel Thermal agnetic ircuit Breaker Series APT Series APT7 and APT9 with Thermal-agnetic ircuit Breaker aximum Horsepower Three Phase B Amps Type 3R Rainproof etal Type 4X orrosion Resistant Non-etallic 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ APT APT 2 5 ~ TB15RO 1622 R TB15O R/F R/F TBH15RO 1767 R TBH15O R/F R/F ~ ~ TBH20RO 1767 R TBH20O R/F R/F ~ TB20RO 1622 R TB20O R/F R/F TBH20RO 1808 R TBH20O R/F R/F 5 10 ~ TB30RO 1703 R TB30O R/F R/F ~ ~ TBH35RO 1889 R TBH35O R/F R/F ~ TB40RO 1744 R TB40O R/F R/F ➋ TB50RO 1865 R TB50O R/F R/F TBH50RO R/F R TBH50O R/F R/F ➋ TB50RO 1906 R TB50O R/F R/F TBH50RO R/F R TBH50O R/F R/F ~ 30 ~ TB70RO 2149 R TB70O R/F R/F 15 ~ ~ TB80RO 2149 R TB80O R/F R/F ➋ TB80RO 2219 R TB80O R/F R/F TBH80RO 2385 R TBH80O R/F R/F ~ ~ 40 ➋ TB80RO 2271 R TB80O R/F R/F ~ ~ TBH80RO R/F R TBH80O R/F R/F ➋ TB100RO R/F R TB100O R/F R/F TBH100RO 2271 R TBH100O R/F R/F ➋ TB125RO 2797 R TB125O R/F R/F TBH125RO R/F R TBH125O R/F R/F ~ TB125RO 2838 R TB125O R/F R/F ~ ~ 75 ➋➌ TB150RO 2954 R TB150O R/F R/F ~ ~ 75 ➌ TBH150RO 3099 R TB150O R/F R/F ~ 75 ➌ ~ TB175RO 2954 R TB175O R/F R/F ~ 75 ~ TB175R0 ➍ R/F T TB1750 ➍ R/F R/F 40 ~ 100 ❸ TB200R0 ➍ R/F T TB2000 ➍ R/F R/F ~ ❸ TB225R0 ➍ R/F T TB2250 ➍ R/F R/F 50 ~ ~ TB250R0 ➍ R/F T TB2500 ➍ R/F R/F TB300R0 ➍ R/F T TB3000 ➍ R/F R/F TB350R0 ➍ R/F TB3500 ➍ R/F R/F ~ 175 ~ TB400R0 ➍ R/F TB4000 ➍ R/F R/F TB450R0 ➍ R/F TB4500 ➍ R/F R/F ~ ~ ~ TB500R0 ➍ R/F TB5000 ➍ R/F R/F TB600R0 ➍ R/F TB6000 ➍ R/F R/F ~ ~ TB600R0 ➍ R/F TB6000 ➍ R/F R/F ~ TB700R0 ➍ R/F TB7000 ➍ R/F R/F 150 ~ E- - -TB700R0 R/F J E- - -TB7000 R/F R/F ~ 350 ~ E- - -TB800R0 R/F J E- - -TB8000 R/F R/F ~ ~ ~ E- - -TB800R0 R/F J E- - -TB8000 R/F R/F E- - -TB1000R0 R/F J E- - -TB10000 R/F R/F ~ ~ E- - -TB1000R0 R/F R/F E- - -TB10000 R/F R/F ~ E- - -TB1200R0 R/F R/F E- - -TB12000 R/F R/F Larger sizes available. ontact your Sprecher + Schuh representative. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages Pump Panel with ircuit Breaker includes: l ontactor (with A coil) l Overload relay protection l Thermal magnetic circuit breaker l START momentary pushbutton l H-O-A selector switch l At minimum, 6 x10 extra back pan space l UL type rated enclosure APT R/F - Experience has shown that applications using non-metallic enclosures often require customized pump panels (i.e. oor-in-oor or unique control circuits). ontact your Sprecher + Schuh representative for a customized price. NOTE: atalog Numbers, list Prices and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying atalog Numbers. ➊ imensional information starts on page 122. ➋ Applicable to 600Y/347V only. ➌ The short circuit and ka is relegated to the contactor s 10kA. ontact your Sprecher + Schuh representative for a higher ka. ➍ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: APT TB175R0 becomes APT9-116-E- - -TB175R0. See page 104 for price adder. Simplex & uplex Pump Panels iscount Schedule B7 93

94 Through-the-door Operator Pump Panels Fusible isconnect - Series APT Simplex & uplex Pump Panels Series APT7 and APT9 with Fusible isconnect (J-Type) ➋➌ aximum Horsepower Three Phase Fuse lips Type 3R Rainproof etal Type 4X orrosion Resistant Non-metallic 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ APT APT JF61RO 1500 R JF61O R/F R/F JF61RO 1540 R JF61O R/F R/F JF61RO 1581 R JF61O R/F R/F ~ ~ ~ JF61RO 1622 R JF61O R/F R/F JF62RO 1703 R JF62O R/F R/F JF62RO 1824 R JF62O R/F R/F JF62RO 1865 R JF62O R/F R/F ~ JF62RO 1906 R JF62O R/F R/F 15 ~ ~ JF63RO 2473 R JF63O R/F R/F ~ ~ JF62RO 2165 R JF62O R/F R/F ~ JF63RO 2570 R JF63O R/F R/F ~ ~ JF62RO 2196 R JF62O R/F R/F JF63RO 2595 R JF63O R/F R/F JF63RO 2636 R JF63O R/F R/F ~ ~ JF63RO 2676 R JF63O R/F R/F ~ JF64RO 3568 H JF64O R/F R/F JF64RO 3684 H JF64O R/F R/F JF64R0 ➍ R/F H JF640 ➍ R/F R/F JF64R0 ➍ R/F H JF640 ➍ R/F R/F JF65R0 ➍ R/F J JF650 ➍ R/F R/F JF65R0 ➍ R/F J JF650 ➍ R/F R/F JF65R0 ➍ R/F J JF650 ➍ R/F R/F JF66R0 ➍ R/F R/F JF660 ➍ R/F R/F JF66R0 ➍ R/F R/F JF660 ➍ R/F R/F 150 ~ E- - -JF66R0 R/F R/F E- - -JF660 R/F R/F ~ 350 ~ E- - -JF67R0 R/F R/F E- - -JF670 R/F R/F E- - -JF67R0 R/F R/F E- - -JF670 R/F R/F Larger sizes available. ontact your Sprecher + Schuh representative. Pump Panel with isconnect Switch includes: l ontactor (with A coil) l Overload relay protection l J-type fusible disconnect switch (excluding line fuses) l START momentary pushbutton l H-O-A selector switch l At minimum, 6 x10 extra back pan space l UL type rated enclosure APT (with PT option) NOTE: atalog Numbers, list Prices and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying atalog Numbers. R/F - Experience has shown that applications using non-metallic enclosures often require customized pump panels (i.e. oor-in-oor or unique control circuit). ontact your Sprecher + Schuh representative for a customized price. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ Fusible combo starters use the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➌ A Red and Yellow Handle may be selected instead of the standard Gray and Black handle. hange JF to LF in catalog number. ➍ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: APT JF64R0 becomes APT9-116-E- - -JF64R0. See page 104 for price adder. 94 iscount Schedule B7

95 NEA Sized Through the-door Operator Pump Panel Series APTN Series APTN7 with Thermal-agnetic ircuit Breaker NEA Size aximum Horsepower Three Phase B Amps Type 3R Rainproof etal Type 4X orrosion Resistant Non-etallic 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ APTN APTN 1/2 2 ~ TB15RO 2494 R TB15O R/F R/F 1/ TBH15RO 2712 R TBH15O R/F R/F 3 5 ~ TB15RO 2555 R TB15O R/F R/F TBH15RO 2733 R TBH15O R/F R/F 7-1/2 ~ ~ TB40RO 2858 R TB40O R/F R/F ~ 10 ~ TB30RO 2858 R TB30O R/F R/F ~ ~ 10 ➍ TB20RO 2858 R TB20O R/F R/F ~ ~ TBH20RO R/F R TBH20O R/F R/F ~ ~ 25 ➍ TB50RO 3210 R TB50O R/F R/F ~ ~ TBH50RO 3428 R TBH50O R/F R/F ~ 25 ~ TB60RO 3210 R TB60O R/F R/F 15 ~ ~ TB80RO 3428 R TB80O R/F R/F ➍ TB100RO 4257 R TB100O R/F R/F TBH100RO 4475 R TBH100O R/F R/F ~ TB125RO 4257 R TB125O R/F R/F Series APTN7 with Fusible isconnect (J-Type) ➋➌ NEA Size aximum Horsepower Three Phase Fuse lips Type 3R ndustrial usttight Type 4X orrosion Resistant Non-etallic 230V 460V 575V atalog No. Price ➊ atalog No. Price ➊ APTN APTN / JF61RO 2311 R JF61O R/F R/F JF61RO 2372 R JF61O R/F R/F 1 7-1/2 ~ ~ JF62RO 2838 R JF62O R/F R/F ~ JF61RO 2707 R JF61O R/F R/F 2 15 ~ ~ JF63RO 3709 R JF63O R/F R/F ~ JF62RO 2858 R JF62O R/F R/F 3 30 ~ ~ JF64RO 5352 H JF64O R/F R/F ~ JF63RO 4014 H JF63O R/F R/F Pump Panel with NEA label includes: l NEA labeled contactor (with A coil) l Overload relay protection l Appropriate disconnect means thermal magnetic circuit breaker) or J-type fusible disconnect switch (excluding line fuses) l START momentary pushbutton l H-O-A selector switch l At minimum, 6 x10 extra back pan space l UL type rated enclosure R/F - Experience has shown that applications using nonmetallic enclosures often require customized pump panels (i.e. oor-in-oor or unique control circuit). ontact your Sprecher + Schuh representative for a customized price. Simplex & uplex Pump Panels NOTE: atalog Numbers, list Prices and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying atalog Numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ imensional information starts on page 122. ➋ Fusible combo starters use the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➌ A Red and Yellow Handle may be selected instead of the standard Gray and Black handle. hange JF to LF in catalog number. ➍ Applicable to 600Y/347V only. iscount Schedule B8 95

96 uplex Pump ontrollers Sprecher + Schuh duplex pump control panels are specifically designed to meet multi-starter combination requirements as defined in demanding outdoor environmental conditions. Simplex & uplex Pump Panels uplex pump controllers are typically designed for two specific requirements: duplexing and alternation. uplexing provides capacity for above normal demand or system peaking by allowing both motors to run simultaneously. t also provides standby capacity if one unit fails. Typically multiple pressure or float switches are required to provide electrical signals to the controller. Alternation provides for equal wear on the two machines being controlled by reversing the lead and lag role of the specific motors. Alternation occurs at any time the two motors come to rest. uplex Pump ontrollers from Sprecher + Schuh offer through-thedoor operators and rugged Type 3R rain-proof metal or Type 4X nonmetallic enclosures. Three models of uplex ontrollers Thermal-magnetic circuit breakers (B) instead of a motor circuit protector (P) to comply with new short-circuit requirements from UL and NE. Heavy duty fusible or non-fusible L11 disconnect switches providing improved short-circuit protection when used with J fuses. Self-protected ombination ontrollers (Type E) KTA7 models which offers superior fuseless short-circuit protection in a smaller more economical package (See page F111). with all requirements by UL and are labeled with the applicable NEA (00, 0, 1, 2, or 3) size in our pump panels. Our B models and the L11 models utilize the EP7 solid state overload relay providing state-of-the-art overload and single-phase protection. See Section B in this catalog for a full description of these excellent motor protection relays. Our KTA7 model utilizes the high speed current limiting capabilities providing short-circuit protection, branch-circuit disconnect, and overload protection in one compact device. These Type E panels are smaller than classic models and therefore represent an economical solution to duplexing. See Section F in this catalog for application details for these Type E ombos. Experience has shown us that duplex pump panels often require customization to accommodate unique components and unique control schematic diagrams. n the following pages you will find a catalog number structure showing standard models with standard options to help guide your selection. We have also provided a check list which can be utilized to request a similar model except customized to meet your application by contacting your Sprecher + Schuh representative. ustom ontrol Panels Sprecher + Schuh custom control facility manufactures custom panels for almost any need, including this duplex control panel in a custom Type 4 stainless steel enclosure. uplex pump panels feature our A7 and A9 line of contactors, which are UL Listed and sized to match all the available HP sizes of motors. Alternately, we can provide NEA Sized (AN7) contactors which comply 96

97 uplex Pump ontrollers ontroller Only - Series APT or Series XP7 uplex Pump Panel hecklist ustomer Name: Project Name: ontact Person: Standard catalog number selected from the following pages: Application ata: with the exceptions noted below Location: Phone No.: ate: otor HP: Voltage: Phase: FLA isconnect? Yes No f yes, type of disconnect: J-Type Fusible Non-Fusible ircuit breaker Type E combination controller Simplex & uplex Pump Panels Starting ethod: Across-the-line Softstarter ontrol Transformer: Yes No f Yes, is there any extra VA capacity required other than what is provided as standard? Extra VA required Options: H-O-A Pilot Light; olor Function Terminal Points; Qty Phase onitor Hour eter Lightning Arrestor Alternator Number of float switches Alarm ircuit Horn Light Type Alarm Silence Button Other ustom Schematic (ust be attached) Enclosure: Type 1 Type 12 Type 13 Type 3R Type 4 Type 4X f Type 4X, non-metallic 304 stainless steel 316 stainless steel oor-in-door (dead front) Special Features: iscount Schedule B7 97

98 uplex Pump ontrollers ontroller Only - Series APT Simplex & uplex Pump Panels Series APT7 and APT9 aximum Horsepower Three Phase Type 3R Rainproof (etal) Type 4X orrosion Resistant Non-metallic 230V 460V 575V atalog No. Price atalog No. Price APT APT RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F RO R/F R/F O R/F R/F R0 ➊ R/F R/F ➊ R/F R/F R0 ➊ R/F R/F ➊ R/F R/F R0 ➊ R/F R/F ➊ R/F R/F R0 ➊ R/F R/F ➊ R/F R/F R0 ➊ R/F R/F ➊ R/F R/F R0 ➊ R/F R/F ➊ R/F R/F R0 ➊ R/F R/F ➊ R/F R/F E- - -R0 R/F R/F E R/F R/F E- - -R0 R/F R/F E R/F R/F E- - -R0 R/F R/F E R/F R/F E- - -R0 R/F R/F E R/F R/F E- - -R0 R/F R/F E R/F R/F E- - -R0 R/F R/F E R/F R/F uplex Pump ontroller includes: (2) ontactors (A coil) (2) Overload relay protection (1) Electronic alternating relay (1) UL type rated enclosure esigned per alternation control diagram shown at bottom of page 119 R/F - Experience has shown that applications using non-metallic enclosures often require customized pump panels (i.e. oor-in-oor or unique control circuit). ontact your Sprecher + Schuh representative for a customized price. Note: atalog numbers, list prices and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying atalog Numbers. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: APT R0 becomes APT9-116-E- - -R0. See page 104 for price adder. 98 iscount Schedule B7

99 uplex Pump ontrollers Thermal agnetic B - Series APT Series APT7 and APT9 with Thermal-agnetic ircuit Breaker aximum Horsepower Three Phase B Amps Type 3R Rainproof (etal) Type 4X orrosion Resistant Non-metallic 230V 460V 575V atalog Number Price atalog Number Price APT APT 2 5 ~ TB15RO R/F R/F TB15O R/F R/F TBH15RO R/F R/F TBH15O R/F R/F ~ ~ TBH20RO R/F R/F TBH20O R/F R/F ~ TB20RO R/F R/F TB20O R/F R/F TBH20RO R/F R/F TBH20O R/F R/F 5 10 ~ TB30RO R/F R/F TB30O R/F R/F ~ ~ TBH35RO R/F R/F TBH35O R/F R/F ~ TB40RO R/F R/F TB40O R/F R/F ➊ TB50RO R/F R/F TB50O R/F R/F TBH50RO R/F R/F TBH50O R/F R/F ➊ TB50RO R/F R/F TB50O R/F R/F TBH50RO R/F R/F TBH50O R/F R/F ~ 30 ~ TB70RO R/F R/F TB70O R/F R/F 15 ~ ~ TB80RO R/F R/F TB80O R/F R/F ➊ TB80RO R/F R/F TB80O R/F R/F TBH80RO R/F R/F TBH80O R/F R/F ~ ~ 40 ➊ TB80RO R/F R/F TB80O R/F R/F ~ ~ TBH80RO R/F R/F TBH80O R/F R/F ➊ TB100RO R/F R/F TB100O R/F R/F TBH100RO R/F R/F TBH100O R/F R/F ➊ TB125RO R/F R/F TB125O R/F R/F TBH125RO R/F R/F TBH125O R/F R/F ~ TB125RO R/F R/F TB125O R/F R/F ~ ~ 75 ➊➋ TB150RO R/F R/F TB150O R/F R/F ~ ~ 75 ➋ TBH150RO R/F R/F TBH150O R/F R/F ~ 75 ➋ ~ TB175RO R/F R/F TB175O R/F R/F ~ 75 ~ TB175R0 ➌ R/F R/F TB1750 ➌ R/F R/F 40 ~ 100 ➋ TB200R0 ➌ R/F R/F TB2000 ➌ R/F R/F ~ ➋ TB225R0 ➌ R/F R/F TB2250 ➌ R/F R/F 50 ~ ~ TB250R0 ➌ R/F R/F TB2500 ➌ R/F R/F TB300R0 ➌ R/F R/F TB3000 ➌ R/F R/F TB350R0 ➌ R/F R/F TB3500 ➌ R/F R/F ~ 175 ~ TB400R0 ➌ R/F R/F TB4000 ➌ R/F R/F TB450R0 ➌ R/F R/F TB4500 ➌ R/F R/F ~ ~ ~ TB500R0 ➌ R/F R/F TB5000 ➌ R/F R/F TB600R0 ➌ R/F R/F TB6000 ➌ R/F R/F ~ ~ TB600R0 ➌ R/F R/F TB6000 ➌ R/F R/F ~ TB700R0 ➌ R/F R/F TB7000 ➌ R/F R/F 150 ~ E- - -TB700R0 R/F R/F E- - -TB7000 R/F R/F ~ 350 ~ E- - -TB800R0 R/F R/F E- - -TB8000 R/F R/F ~ ~ ~ E- - -TB800R0 R/F R/F E- - -TB8000 R/F R/F E- - -TB1000R0 R/F R/F E- - -TB10000 R/F R/F ~ ~ E- - -TB1000R0 R/F R/F E- - -TB10000 R/F R/F ~ E- - -TB1200R0 R/F R/F E- - -TB12000 R/F R/F uplex Pump ontroller with circuit breaker includes: (2) ontactors (A coil) (2) Overload relay protection (2) Thermal magnetic circuit breakers (1) Electronic alternating relay (1) UL type rated enclosure esigned per alternation control diagram shown at bottom of page 119 R/F - Experience has shown that applications using non-metallic enclosures often require customized pump panels (i.e. oor-in-oor or unique control circuit). ontact your Sprecher + Schuh representative for a customized price. Note: atalog numbers, list prices and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying atalog Numbers. Simplex & uplex Pump Panels Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ Applicable to 600Y/347V only. ➋ The short circuit and ka is relegated to the contactor s 10kA. ontact your Sprecher + Schuh representative for a higher ka. ➌ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: APT TB175R0 becomes APT9-116-E- - -TB175R0. See page 104 for price adder. iscount Schedule B7 99

100 uplex Pump ontrollers Fusible isconnect - Series APT Simplex & uplex Pump Panels Series APT7 and APT9 with Fusible isconnect (J-Type) ➊➋ aximum Horsepower Three Phase Fuse clip Amps Type 3R Rainproof (etal) Type 4X orrosion Resistant Non-metallic 200V 230V 460V 575V atalog Number Price atalog Number Price APT APT JF61RO R/F R/F JF61O R/F R/F JF61RO R/F R/F JF61O R/F R/F JF61RO R/F R/F JF61O R/F R/F 5 ~ ~ ~ JF61RO R/F R/F JF61O R/F R/F ~ JF62RO R/F R/F JF62O R/F R/F JF62RO R/F R/F JF62O R/F R/F JF62RO R/F R/F JF62O R/F R/F 10 ~ JF62RO R/F R/F JF62O R/F R/F ~ 15 ~ ~ JF63RO R/F R/F JF63O R/F R/F ~ ~ ~ JF62RO R/F R/F JF62O R/F R/F ~ JF63RO R/F R/F JF63O R/F R/F ~ ~ ~ JF62RO R/F R/F JF62O R/F R/F JF63RO R/F R/F JF63O R/F R/F JF63RO R/F R/F JF63O R/F R/F ~ ~ ~ JF63RO R/F R/F JF63O R/F R/F ~ JF64RO R/F R/F JF64O R/F R/F JF64RO R/F R/F JF64O R/F R/F JF64R0 ➌ R/F R/F JF640 ➌ R/F R/F JF64R0 ➌ R/F R/F JF640 ➌ R/F R/F JF65R0 ➌ R/F R/F JF650 ➌ R/F R/F JF65R0 ➌ R/F R/F JF650 ➌ R/F R/F JF65R0 ➌ R/F R/F JF650 ➌ R/F R/F JF66R0 ➌ R/F R/F JF660 ➌ R/F R/F JF66R0 ➌ R/F R/F JF660 ➌ R/F R/F ~ E- - -JF66R0 R/F R/F E- - -JF660 R/F R/F ~ ~ 350 ~ E- - -JF67R0 R/F R/F E- - -JF670 R/F R/F E- - -JF67R0 R/F R/F E- - -JF670 R/F R/F uplex Pump ontroller with disconnect switch includes: (2) ontactors (A coil) (2) Overload relay protection (2) J-type fusible disconnect switch (excluding line fuses) (1) Electronic alternating relay (1) UL type rated enclosure esigned per alternation control diagram shown at bottom of page 119 Note: atalog numbers, list prices and enclosure dimensions reflect contactors with A coils. For coils, select oil ode from the oil ode table on page 104 and follow the instructions for modifying atalog Numbers. R/F - Experience has shown that applications requiring duplex pump panels often require customization. (i.e.: unique components and control circuits). ontact your Sprecher + Schuh representative for a customized price. Ordering nstructions Specify atalog Number Replace (Q) with oil ode Replace ( ) with O/L Relay Factory odifications available See page 104 See pages See pages ➊ Fusible combo starters use the L11 isconnect. Fuse clips accept J type fuses. Power fuses not supplied. ➋ A Red and Yellow Handle may be selected instead of the standard Gray and Black handle. hange JF to LF in catalog number. ➌ AT9-116 AT9-370 starters are available with E option for PL interface. hange catalog number to include -E. Example: APT JF64R0 becomes APT9-116-E- - -JF64R0. See page 104 for price adder. 100 iscount Schedule B7

101 Type E/F ombination ontrollers An alternative to the lassic ombination Starter onstruction Type E/F E-ombo Self-Protected otor ontroller lassic onstruction Type A Fusible ombination Starter lassic onstruction Type Thermal agnetic B ombination Starter The lassic ombo lassic combination starters in onstruction Type A use fusible L11 isconnect switches. ontruction Type combos use UL489 olded ase ircuit Breakers. Both are popular choices but Sprecher + Schuh s E-ombo line offers an alternative. Advanced Alternative Technology has advanced in the last two decades and UL, NE, and SA now recognize Self-Protected ombination otor ontrollers as providing a means of thru-the-door disconnect, short circuit protection, and overload protection in a single device (KTA7). Further, when KTA7 is combined with A7 contactors for remote operation, the resulting assembly is a onstruction Type E/F ombination Starter. Less components and a smaller enclosure means a functional equal to the lassic ombo at a reduced price. The E-ombo Starter Sprecher + Schuh s Ecombo and EcomboPlus starters are the compact alternative to larger and higher priced combination starters. E-ombos include: KTA7 Type E/F Self-protected otor ontroller with 1 N.O. front mount auxiliary contact A7 or AN7 ontactors (for remote operation) Terminal Adaptor for Type E Applications Power and ontrol Wiring Type 12/4 enclosure, dual rated - watertight, dusttight Gray/Black or Red/Yellow Type 4/4X/12; P66 handle Factory installed pilot device options Higher SR ratings than B combination versions All in a smaller NEA Type 4/12 enclosure at a more economical price. For details on these economical combination starter alternatives turn to atalog Number Selection, page F105. Simplex & uplex Pump Panels See page F105 for Type E/F ombination Starter ontrol Panels onstruction Type E/F Reversing E-ombo Self-Protected otor ontroller 101

102 Accessories - Field nstallable A7 ontactors Type 1 General Purpose Enclosures ➋➌ Starters & Enclosed Products Enclosure (Box) Kit ncludes: Hinged cover Backpan pre-drilled for listed arrangements (not tapped) (2) Ground Lugs and Symbol label (2) 22mm knockouts for pilot devices ➍ EP7-ERA Overload Reset Adapter R7 Reset Kit for over (2) 22mm knockouts for Reset ➎ ual onduit knockouts - Top and Bottom A Box - (2) 1/2 to 3/4" and (1) 3/4 to 1" B Box - (2) 1/2 to 3/4", (1) 1 to 1-1/4", (1) 3/4 to 1" (4) 8-32 x 1/2" screws for mounting controllers B Box also includes (2) x 3/4" screws oes not include wire A Box Kit B Box Kit atalog Number Price atalog Number Price A B 145 Optional: 35mm N Rail Kit with (2) x 1/4 screws ➋ SF-2 (2 inches long) 8 SF-3 (3 inches long) 10 imensions ➏ 10 x 8 x 6 Type 1 Enclosure 12 x 10 x 6 Type 1 Enclosure For use with overload A Box Kit accommodates B Box Kit accommodates For use with ontroller EP7-E1* EP7-EE* T7N Use with Use with Space for Use with Use with Use with Space for No PT 50VA PT ➌ 2" N Rail ➋ No PT 50VA PT 100VA PT ➌ 3" N Rail ➋ Non-reversing ontactors A ~ ~ ~ A ➐ ~ ~ ~ No No No N/A Reversing ontactors AU ~ ~ ~ No AU ~ ~ ~ No No No AU ➐ ~ ~ ~ No No No No N/A No No Non-Reversing Starters AT ➊ AT ➊ AT ➐ N/A ➊ No No No N/A Reversing Starters AUT ➊ No AUT ➊ No AUT ➊ No No No AUT ➐ N/A No No No No No No No No No NEA Sized Non-reversing Starters ATN ➊ ATN7-37 ➊ ATN7-43 ➊ ATN7-85 N/A ➊ No No No N/A ➊ Alternatively T7N overload relay can be used which will require T7N-RA3 Reset Adapter. Not included in the kit. Order separately. ➋ 2 N rail can accommodate up to (3) V7-W4 TB s or equivalent N rail mount timers, relays, etc. Order kit SF-2 separately. 3 N rail can accommodate up to (6) V7-W4 TB s or equivalent N rail mount timers, relays, etc. Order kit SF-3 separately. ➌ Enclosure designed for use with PT with top mount secondary fuse, plus back pan mounted Ambus Fuseholder with (2) primary fuses. A PT and the addition of extra terminal blocks or other control relay using the 2 N rail space may require a design change. ➍ This enclosure is designed for use with a 7 multi-function Start/Stop as standard plus a 7 monolithic pilot light to fit the (2) 22mm knockouts provided. Additional pilot device holes will require field drilling and may interfere with the controller or the addition of a PT or TB s. ➎ (2) 22mm knockout locations are provided for one reset Kit to be located contingent on the type of controller used. See box nstruction sheet for mounting details of controller and reset kit. ➏ For enclosure dimensions see page 122 ➐ A7-97 and AT7-97 will not fit in B Box because of wire bending space requirements. See Selection tables for box sizes starting on page 122 for dimensions. 102 iscount Schedule B7 ~ All prices - All are pricing in US shown dollars, in effective US dollars 1/1/2018

103 Accessories Field nstallable Enclosure Pilot evice Kits & Ratings efinitions Pilot evice Kits All applications (except Kwikstarters and Explosion Proof enclosures) ➊ Kits ontact Blocks included escription NO N ulti-function Pushbutton kit ➋ START-STOP 1 1 Non-illuminated, Standard for A and B Box Kits. ulti-function Pushbutton kit ➋ FORWAR-STOP-REVERSE 2 3 Non-illuminated, Standard for A and B Box Kits. STOP and START Two button pushbutton kit 1 1 FORWAR, REVERSE and STOP Three button pushbutton kit HAN-OFF-AUTO selector switch kit Name plate included. FW-OFF-REV selector switch kit Name plate included. OFF-ON selector switch kit Name plate included. onolithic Pilot Light kit LE Lamp and lens cap oes not include nameplate ~ For Use With Enclosure... atalog Number Price Type 1, 12, 3R, 4, 4X, 13 SS6-7P 53 Type 1, 12, 3R, 4, 13 SS Type 1, 12, 3R, 4, 4X, 13 SS5-7P 100 Type 1, 12, 3R, 4, 13 SS Type 1, 12, 3R, 4, 4X, 13 SS1-7P 62 Type 1, 12, 3R, 4, 13 SS Type 1, 12, 3R, 4, 4X, 13 SS7-7P 115 Type 1, 12, 3R, 4, 13 SS Type 1, 12, 3R, 4, 4X, 13 SS2-7P 52 Type 1, 12, 3R, 4, 13 SS Type 1, 12, 3R, 4, 4X, 13 SS9-7P 52 Type 1, 12, 3R, 4, 13 SS Type 1, 12, 3R, 4, 4X, 13 SS4-7P 40 Type 1, 12, 3R, 4, 13 SS Type 1, 12, 3R, 4, 4X Replace with color choice R = Red G = Green SS V SS V SS V 36 Starters & Enclosed Products Example of pushbutton kits on an A Box ➊ Pilot evice Kits do not include control wires. See instruction sheet for installation. ➋ ulti-function START/STOP pushbutton are standard for General Purpose Type 1(1) dimensions A and B enclosures. iscount Schedule B7 ~ All prices - All are pricing in US shown dollars, in effective US dollars 1/1/

104 Starter odification odes A.. oil odes & Voltage Ranges ➊➎ All catalog numbers, list prices and enclosure dimensions in the previous section reflect contactors with A coils. f necessary, add the appropriate price adder to the list price for each coil required as shown in the online catalog. Remember that reversing applications require two coils. Price Adder x 2. A.. oil odes (Replace Q in cat.# with coil code) 24 A7-9 thru A7-97 AN Hz 60 Hz 24Z 24V 24V 110 ~ ~ V 120V 120B ~ ~ 208 ~ 208V 208W ~ ~ 220W ➋ V V V 240V 240B ~ ~ 240W ~ ~ V 277V V 440V 440W ~ ~ 460W ~ ~ V 480V 575 ~ ~ V 600V Price Adder ~ ~ A / oil odes & -E oil Upgrade Adders All ontactor and Starter onfigurations.. oil odes & Voltage Ranges ➊➎ For starters with coils, select oil ode from the table below. Remember that reversing applications require two coils (Price Adder x 2). Starter catalog numbers must be modified when using coils. For example: For AT contactors, add an E to catalog number for Electronic oils. i.e.: AT7-9 becomes AT7-9E For AT contactors, add a to catalog number. i.e.: AT7-60 becomes AT oil odes (Replace Q in cat.# with coil code) ➏ ➏ ➍ A7-9E..37E AN7-12E 37E A7-43E 55E AN7-43E A AN7-85 A7 ode Voltage Voltage Voltage 12E 12VE 12VE ~ 24E 24VE 24VE ~ 24 ~ ~ 24V 36E 36-48VE 36-48VE ~ 48E 48-72VE 48-72VE ~ 48 ~ ~ 48V 110E 110VE 110VE ~ 110 ~ ~ 110V ~ ~ ~ ~ 125 ~ ~ 125V 220E 220VE 220VE ~ 220 ~ ~ 220V 250 ~ ~ 250V Price Adder ➎ AT9 A/ oil odes and Voltage Ranges ➋➌➎ Electronic oils V 24-60V V V V Price Adder for (Replace Q in cat.# with coil code) PL option A A/ 24W 48W 120W 480W ~ A9-116-E 370-E ~ ~ 120W 480W 50 A9-400-E 750-E 24W ➐ 48W 120W 480W ~ A9-860-E 1060-E A/ with PL nput ~ ~ 120W ~ ~ A E 24W ➐ 48W 120W 480W ~ A E 2650-E ~ ~ 120W ~ ~ ➊ Only the most common coils are shown here. Other coil voltages may be available. Refer to ontactor Renewal Parts in Section A of this catalog, or contact your nearest Sprecher + Schuh sales office. ➋ Wide range coil. ➌ E oils are designed to operate with PL interface. ➍ coils are standard for A ➎ Reversing applications require two coils. Add appropriate price adder(s) to list price of enclosed contactors and starters. Remember to add price for each coil required. ➏ A7-9E...55E electronic coils are not interchangeable with non-electronic or A coils. ➐ This coil range is 24-60V only ~ All prices - All are pricing in US shown dollars, in effective US dollars 1/1/2018

105 A7 ontactor with EP7 Overload Relay ➊➌➍ For use with contactor... Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay) Price Adder 3-Phase / anual Reset / lass AB EP7-E1AB Standard A7-9...A BB EP7-E1BB Standard B EP7-E1B Standard B EP7-E1B Standard EB EP7-E1EB Standard EP7-E1 Standard A A EP7-E1 Standard E EP7-E1E Standard F EP7-E1F Standard 3-Phase / Auto or anual / Adjustable Trip lass 10, 15, 20 & EAB EP7-EEAB 17 A7-9...A EBB EP7-EEBB EB EP7-EEB EB EP7-EEB EEB EP7-EEEB E EP7-EE 21 A A E EP7-EE EE EP7-EEE EF EP7-EEF 21 A EQ EP7-EEQ Standard EEE EP7-EEEE Standard A A EFE EP7-EEFE Standard EGE EP7-EEGE Standard EVE EP7-EEVE Standard B7 ontactor with EP7 Overload Relay EP7 Second Generation Overload Relay odes Series AT7 and AT6 Starters Large Amp EP7 Solid State Overload Relays, Automatic or anual Adjustable Trip lass ➊➋➌➍ irectly ounts to ontactor ➋ Adj. Range (A) Overload Relay ode ( ) T Ratio atalog Number (of Overload Relay) Automatic or anual Reset for 3-Phase Applications Adjustable Trip lass 10, 15, 20 & 30 Price Adder A EHJ 150:5 EP7-EEHJ Standard A EJJ 200:5 EP7-EEJJ Standard A T3 300:5 ➎ Standard A T6 600:5 ➎ Standard A ~ Refer to Factory Standard Special Notes: Wye-elta Starters - First multiply motor full load current by 58%. Then, using this figure, select appropriate Overload Relay ode from tables above. Part Winding Starters - First multiply motor full load current by 50%. Then, using this figure, select appropriate Overload Relay ode from tables above. Variable Frequency rives - EP7 solid state overload relays cannot be utilized on VFs or Softstarters with Braking option. Starter odification odes For use with contactor... Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay) Price Adder 1-Phase / Automatic or anual Reset / lass 10 A7-9...A EPB EP7S-EEPB Standard ERB EP7S-EERB Standard ESB EP7S-EESB Standard A7-30..A ET EP7S-EET Standard A A EUE EP7S-EEUE Standard This item is available in the ORANGE E PRESS 3-day shipping program ➊ 3-phase EP7 units are only designed for 3 applications. Single phase EP7S units are only designed for 1 applications. ➋ This reference is not intended to be a guide for selecting contactors. Size overload relays using the full load current of the motor. ➌ The reset time of a EP7 set in the automatic mode is approximately 180 seconds. ➍ EP7 Overload relays do not work with Variable Frequency rives or any Sprecher + Schuh Softstarter with braking options. ➎ Utilizes UL approved urrent Transformers and a EP7-EEB overload relay. Refer to page B13 for current setting guidance. For E approved urrent Transformers refer to factory. ~ All prices - All are pricing in US shown dollars, in effective US dollars 1/1/

106 Thermal Overload Relay odes EP7-ER Kits and T7N on Series AT7 Starters Starter odification odes ntelli-button Reset Kit Factory odification The EP7-ER ntelli-button plus your choice of side-mounted module can be orderd as a factory modification, installed in any control panel built by Sprecher + Schuh that contains a EP7-EE_ overload relay. Just add the kit suffix shown below to the end of the starter catalog number. For example, AT EEB-G0 becomes AT EEB-G0-B2 EP7-ER + Side ount odule... Remote Reset Only Jam and Remote Reset Thermistor Relay and Remote Reset Ground Fault and Remote Reset Ground Fault and Jam and Remote Reset odule Add to end of atalog Number -B1 -B2 -B3 -B4 -B5 -B6 -B7 -B8 -B9 -B10 -B11 Kit includes... EP7-ER EP7-ERR EP7-ER EP7-EJ (B) EP7-ER EP7-EPT EP7-ER EP7-EGF EP7-BT1 (45A) EP7-ER EP7-EGF EP7-BT2 (90A) EP7-ER EP7-EGF EP7-BT3 (180A) EP7-ER EP7-EGF EP7-BT4 (420A) EP7-ER EP7-EGJ EP7-BT1 (45A) EP7-ER EP7-EGJ EP7-BT2 (90A) EP7-ER EP7-EGJ EP7-BT3 (180A) EP7-ER EP7-EGJ EP7-BT4 (420A) Price Adder A7 Starters with optional T7N Bimetallic Overload Relay ➊ irectly ounts to ontactor... A7-9 A7-23 Frame A A7-30 A7-37 Frame B A Frame A7-60 A7-97 Frame Amp Range Overload Relay ode ( ) atalog Number (of Overload Relay used) AA16 T7N-23-A AA25 T7N-23-A AA40 T7N-23-A AA50 T7N-23-A AA63 T7N-23-A AA80 T7N-23-A AB10 T7N-23-B AB13 T7N-23-B AB16 T7N-23-B AB20 T7N-23-B AB25 T7N-23-B AB32 T7N-23-B AB40 T7N-23-B AB48 T7N-23-B AB63 T7N-23-B AB75 T7N-23-B A10 T7N A12 T7N A16 T7N A20 T7N A21 T7N A25 T7N B20 T7N B21 T7N B25 T7N B30 T7N B36 T7N B38 T7N T7N T7N T7N T7N T7N T7N T7N T7N T7N Price Adder This item is available in the ORANGE E PRESS 3-day shipping program Special Notes: Wye-elta Starters - First multiply motor full load current by 58%. Then, using this figure, select appropriate Overload Relay ode from tables above. Part Winding Starters - First multiply motor full load current by 50%. Then, using this figure, select appropriate Overload Relay ode from tables above. ➊ Separately mounted overload is available. See Section B ~ All prices - All are pricing in US shown dollars, in effective US dollars 1/1/2018

Starters + Enclosed Product

Starters + Enclosed Product Starters + Enclosed Product General escription... 1 KWKstarters... 4 Enclosed ontactors... 11 agnetic otor Starters... 19 ombination Starters... 27 Explosion-Proof Starters... 34 ulti-speed Starters...

More information

Reduced Voltage Starters

Reduced Voltage Starters Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current

More information

Reduced Voltage Starters

Reduced Voltage Starters Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current

More information

page 10/20 page 10/21 pages 10/21-10/22 page 10/22 page 10/23 none 1 or 2 1 push button extended head red 3 or 4 1 twist lock mushroom red

page 10/20 page 10/21 pages 10/21-10/22 page 10/22 page 10/23 none 1 or 2 1 push button extended head red 3 or 4 1 twist lock mushroom red Rated agnetic Starters Industrial ontrols Product atalog 019 Section contents / Full Voltage Non-Reversing NEA X Non-etallic / Full Voltage etallic /8 Non - ombination /9 ircuit Breaker ombination / Fusible

More information

POWER PRODUCT Low Voltage Motor Starters Contents

POWER PRODUCT Low Voltage Motor Starters Contents POWER PRODUT Low Voltage otor Starters ontents - Full Voltage Non-Reversing NEA X Non-etallic - Full Voltage etallic -8 Non - ombination -9 ircuit Breaker ombination - Fusible Switch ombination and Non-Fusible

More information

Low Voltage Motor Starters

Low Voltage Motor Starters SIRIUS Low Voltage otor Starters ontents Pages... / Full Voltage Non-Reversing NEA X Non-etallic.... / Full Voltage etallic... /8 Non - ombination.... /9 ircuit Breaker ombination.... / Fusible Switch

More information

ECL03B1AAA 20A 120V Lighting Contactor

ECL03B1AAA 20A 120V Lighting Contactor 80 South Street 7-7, TX Nacogdoches Phone: --71 Fax: -0-8 L01 0 V Lighting ontactor aton orp Number L01 Manufacturer aton orp escription Lighting ontactor, lectrically eld; Pole; 77/80 V (Filament Lamp),

More information

AEB Series Bolted Motor Starters and Contactors Explosionproof, Dust-Ignitionproof, Watertight Full Voltage. Combination and Non-Combination.

AEB Series Bolted Motor Starters and Contactors Explosionproof, Dust-Ignitionproof, Watertight Full Voltage. Combination and Non-Combination. AEB Series Bolted otor Starters and ontactors ull Voltage. ombination and Non-ombination. lass I, Division and, roups B,, D lass I, Zone and, roups IIB + H lass II, Division and, roups E,, lass III NEA

More information

Application Description

Application Description - N Mechanically Held February ontents Description Page Product Description...... - Application Description... - Features................ - Operation.............. - Instructional Leaflets..... - Standards

More information

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3. 6-4 Freedom Pump Panels Circuit reaker R Enclosure / -Phase Magnetic / Interchangeable eater OLR These ECN Irrigation Pump Controllers feature the Cutler-ammer Freedom Series starters. They have a AND/OFF/AUTO

More information

Heavy Duty Motor Starters

Heavy Duty Motor Starters ^^ eavy uty Motor Starters Melting oy Overload, Manual Reset lass Ordering nstructions > Use complete catalog number Replace the (*) with letter from the coil table. ual voltage coils are wired on high

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >

More information

150 C 30 F B D 8L 152H C 30 F BD 43 8L

150 C 30 F B D 8L 152H C 30 F BD 43 8L ulletin SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number Solid-State ontroller b ontroller Type SM- c mpere s N F d Enclosure Type Open

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection IPS INTELLIGENT PUMP STARTER With TM Smartstart Ø & Ø, 0/60 Hz, 20~600 VAC, /~00HP Integrated electronic pump protection overload Power metering and data logging options Motor Protection Key dealer yr.

More information

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87 Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................

More information

For Immediate Delivery call KMParts.com at (866)

For Immediate Delivery call KMParts.com at (866) Return To MAIN INDEX Magnetic Contactors, Overview / Contactors DIL...M Contactors AC Operated AC Operated, Reversing DC Operated AC/DC Operated, DC Hp ratings / /6 /8 / Starters DIL Universal Contactors

More information

NEMA Size 1 Cat. No. CN55DN3AB

NEMA Size 1 Cat. No. CN55DN3AB -80 Contactors and Contents Description Product Family Overview Page Product Description....... -78 Features................ -78 Standards and Certifications........... -78 Selection.............. -79

More information

Open Type. SAO12b SAG12b Use Size 0 Use Size 0. SBO2b SBG2b SBW12b SBW22b

Open Type. SAO12b SAG12b Use Size 0 Use Size 0. SBO2b SBG2b SBW12b SBW22b www.schneider-electric.us SO, -Pole Starter ull Starters Rated lass 86 / Refer to atalog 80T70 eneral nformation S magnetic starters are used for full-voltage starting stopping squirrel cage motors. overload

More information

Variable Transformers Product Design & Engineering Data

Variable Transformers Product Design & Engineering Data Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,

More information

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty. Page -2 Page - DIRECT-ON-LINE STARTERS Motor ratings up to 9A 0V in IEC AC duty General use up to 6A / motor rating up to 2A 600V per UL/CSA Versions with Start-Stop/Reset buttons or Reset button Versions

More information

AC Magnetic Starters (GE)

AC Magnetic Starters (GE) AC Magnetic Starters (GE) Description of Operation With Local or Remote Start-Stop Selector Switch (LVR) Control Starting Stopping Restarting Turning the selector switch to START energizes M and starts

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads) Overview Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 Sizes Are coordinated with the dimensions, connections S00...S3 S00... S12 S00... S12 and technical characteristics of the other devices in the

More information

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV Certificate Number 20081124 E29197A Page 1 of 8 Report Reference E29197, 1974 September 17 Issue Date 2008 November 24 Issued to: This is to certify that representative samples of SIEMENS ENERGY & AUTOMATION

More information

C-Series. Circuit Breaker.

C-Series. Circuit Breaker. -Series ircuit Breaker The -Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

ECET 211 Electrical Machines and Controls

ECET 211 Electrical Machines and Controls ECET 211 Electrical Machines and Controls 2016/4/27 Class Review and Wrapping Up Comprehensive Exam, Friday, 1:00-3:00 PM, May 6, 2016 Close books/allow 1-page (8 x 11 and ½) hand-written review note,

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Switches & Pilot Devices

Switches & Pilot Devices ømm - HW Series Key features: ocking lever removable contact blocks Finger-safe IP0 contacts as standard, other terminal styles available Tamperproof construction All E-stops meet EN8 and are compliant

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations

More information

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers .5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings

More information

Switches Unlimited Contact: Phone: Fax:

Switches Unlimited Contact: Phone: Fax: Phone: 8--87 Fax: 78-67-67 - C Coil Three Pole - Series C7 C7 Non-Reversing, Three Pole With C Coil, Series C7 (Open type only) [] Ratings for Switching C Motors (C / C / C) kw (5 Hz) UL/CS HP (6 Hz) uxiliary

More information

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase... SECTION BUCK-BOOST TRANSFORMERS A simple and economical way to correct offstandard voltages... from 95 to 500 volts; single and three phase, in sizes up to 60 kva. Simplified buck-boost rating charts make

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Siemens AG 0 Overview These RA contactor assemblies for wye-delta starting are designed for standard

More information

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC) Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,

More information

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S10N06P0P KVA 1PH 10/40V 16/3V Buck Boost Transformer Eaton Corp Catalog Manufacturer Description Weight per unit Product

More information

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find

More information

For Immediate Delivery call KMParts.com at (866)

For Immediate Delivery call KMParts.com at (866) Moeller Wiring Manual / Page Overview - ON-OFF Switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-speed switches - Interlock

More information

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General Section 16621A - AUTOMATIC TRANSFER SWITCH Part 1 General 1.01 One 600 Amp, 3 Phase, 480 Volt Automatic Transfer Switch (ATS) shall be provided with gasketed enclosure. The ATS shall consist of an inherently

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

FDM Medium Voltage Controller

FDM Medium Voltage Controller 1-1 LMR PLUS Product Description For over 50 years, EATON Corporation has been the industry leader in Medium Voltage Motor Control. The FDM Medium Voltage Fire Pump Controller is based on the AMPGARD controller

More information

2.1. Product Description

2.1. Product Description .1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................

More information

Transformer Questions & Answers

Transformer Questions & Answers Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed

More information

Steps for Selecting the Proper Transformer

Steps for Selecting the Proper Transformer SECTION I Page 4 Steps for Selecting the Proper Transformer SINGLE PASE LOADS 1. Determine electrical load A. Voltage required by load. B. Amperes or KVA capacity required by load. C. Frequency in z (cycles

More information

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient

More information

Creating Electrical Designs

Creating Electrical Designs C h a p t e r 2 Creating Electrical Designs In this chapter, we will learn the following to World Class standards: Understanding Control and Power Circuits Drawing the Control Circuit Selecting the Pushbutton

More information

Jefferson Electric Inc Product Catalog JE901

Jefferson Electric Inc Product Catalog JE901 Jefferson Electric Inc Product Catalog JE901 Worldwide Products and Services Tradition of Excellence Jefferson Electric has been a pioneer and innovator of magnetic products since 1915. We enjoy a rich

More information

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation Variable Frequency Drive Packages with Harmonic Mitigation Low Harmonic Drive Packages Engineered by Rockwell Automation What Do I Need to know About Harmonics? What are Harmonics? Harmonics are deviations

More information

HPS Universal BUCK-BOOST TRANSFORMERS

HPS Universal BUCK-BOOST TRANSFORMERS BUCK-BOOST TRANSFORMERS Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e FIGURE 12-1 Basic relay construction. FIGURE 12-2 Shading coil in AC relays. 1 FIGURE 12-3 Contactor coil and shaded pole stators. FIGURE 12-4 Magnetic motor starter. 2 FIGURE 12-5 Thermal overload devices.

More information

NEMA Contactor and Starter Specifications

NEMA Contactor and Starter Specifications Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental

More information

Type MCAG 14, 34 T&D. High Stability Circulating Current Relay

Type MCAG 14, 34 T&D. High Stability Circulating Current Relay PROTETION Type MAG, 3 High Stability irculating urrent Relay The MAG relay, used with a stabilising resistor, is designed for applications where sensitive settings with stability on heavy through faults

More information

Transformer Questions & Answers

Transformer Questions & Answers Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

3RH1 contactor relays, 4- and 8-pole

3RH1 contactor relays, 4- and 8-pole Siemens AG 2010 RH, TH Contactor Relays RH1 contactor relays, 4- and 8-pole Overview AC and DC operation IEC 60947, EN 60947. The RH1 contactor relays are suitable for use in any climate. They are finger-safe

More information

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg Contactors & Relays Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators Pg 223 230 231 232 232 Contactors & Relays Contactor - GMC Series 3 Pole (240V) AC 1 Rati

More information

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.

More information

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design

More information

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) 1 PART 1: GENERAL This section describes materials and installation requirements for low voltage

More information

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Switching Devices Contactors and Contactor Assemblies for Switching Motors Switching Devices Contactors and Contactor Assemblies for Switching Motors groups 41B, 41H / Introduction Power contactors for switching motors /5 General data /11 SIRIUS RT10 contactors, -pole,... 50

More information

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4 /0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors

More information

MODEL 421 Over/Under Motor Load Monitor

MODEL 421 Over/Under Motor Load Monitor MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart

More information

XT IEC Power Control Miniature Controls

XT IEC Power Control Miniature Controls Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)

More information

ASTAT-XT RVSS PANEL. Table of Contents. Installation and Start-up Instructions for ASTAT-XT RVSS Bypass & Non Bypass Panels DEH40620

ASTAT-XT RVSS PANEL. Table of Contents. Installation and Start-up Instructions for ASTAT-XT RVSS Bypass & Non Bypass Panels DEH40620 DEH 40621 Instruction Table of Contents Section Topic Thanks information DEH40627 Installation and Start-up Instructions for ASTAT-XT RVSS Bypass & Non Bypass Panels DEH40620 Operating and Troubleshooting

More information

Detecting Devices. 8/2 Introduction

Detecting Devices. 8/2 Introduction Detecting Devices /2 Introduction /4 General data / 3SE5, plastic enclosures /16 3SE2, plastic enclosures /22 3SE5, metal enclosures /30 3SE2, metal enclosures /39 3SE3, metal enclosures Compact design

More information

Power-Sure 700. Technical Data TD158001EN. Contents

Power-Sure 700. Technical Data TD158001EN. Contents Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications...

More information

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase

More information

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems Softstarters Type PST Low Voltage Products & Systems 2 Low Voltage Products & Systems 1SXU132171M0201 [AC 1006.8] - 5/03 ABB Inc. 888-385-1221 www.abb.com/lowvoltage Softstarters Type PST Specification

More information

DISCONNECT SWITCHES. UL Listed CSA Certified

DISCONNECT SWITCHES. UL Listed CSA Certified POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole

More information

PHOENIX CONTACT

PHOENIX CONTACT Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode

More information

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor

More information

BUCK-BOOST TRANSFORMERS

BUCK-BOOST TRANSFORMERS Where Are Buck-Boost Transformers Used? A typical buck-boost application is 120 volts in, 12 volts out for low voltage lighting or control circuitry. In most applications, this low voltage transformer

More information

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice. Instruction Manual Bypass Panels FRENIC-EcoPAK Fuji Electric Corp. of America FECA-IN-105 / 122010 Information subject to change without notice. Safety Precautions Read this manual thoroughly before proceeding

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Compact Combination Starters Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for

More information

Ampgard The name motor applications rely on

Ampgard The name motor applications rely on Medium-voltage motor control The name motor applications rely on Oil and gas Mining Water/wastewater Pulp and paper Utility A legacy of reliability for more than 4 decades 1950 1960 1970 1980* 1990 2000

More information

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max. Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......

More information

SINPAC Switches: Brief Operating Description. Mounting Options

SINPAC Switches: Brief Operating Description. Mounting Options SINPAC Switches: Brief Operating Description For over 75 years, single-phase motors have utilized a mechanical centrifugal switch to switch the start circuit. Inherent characteristics of a mechanical device

More information

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL ESP Product Warranty Zener Electric warrant the Electronic Shear Pin against defective workmanship and materials for a period of 24 months from the

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

Supplemental Motor Protection Devices Specifications

Supplemental Motor Protection Devices Specifications Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Page 809S/813S/814S/817 Dedicated Function Motor Protection Relays 2 Product

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION! INSTALLATION INSTRUCTIONS FOR SYMCOM S OVERLOAD RELAY MODEL 777-MV-FT BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE

More information

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type PAGE 2 of 6 2.14 Main Cable Type HO7RN-F4G10-15 Metres each 2.15 (a) O/P Voltage-350V(Max.) (b) O/P Current 150A(Max.) 2.16 Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type 2.17

More information

ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP

ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP Product information presented here re fl ects con di tions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO:

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

Solid-State Switching Devices

Solid-State Switching Devices SIRIUS Solid-State Switching Devices Contents Pages Introduction.................................. 8/2 Solid-state switching devices General data.................................. 8/3 Solid-state switching

More information

CEU Certification Test Drive Road Show: TRM040-DrivesRoadShow-CEU

CEU Certification Test Drive Road Show: TRM040-DrivesRoadShow-CEU Taking the Certification Test Please record all answers on this answer sheet. The total number of points possible on this test is 35. A passing score is 80% or better (no more than 7 wrong). Returning

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION SECTION 15190 MECHANICAL IDENTIFICATION PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Identification of mechanical products installed under Division 15. B. Related Sections: 1.02 REFERENCES 1.

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL AN25 Totalizer/ Rate Indicator DOC#: MN-AN25.doc Sponsler Co., Inc. AN25 Totalizer/Rate Indicator pg. 2 DOC#: MN-AN25 SPECIFICATIONS Temperature: Operating 0 to 70 C Storage

More information

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers INTERNATIONAL TRANSFORMERS Acme Electric s broad selection of CSA energy efficient transformers International Transformers What is CSA C802.2 Compliant? On January 1, 2005, the Canadian Energy Efficiency

More information

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2

More information

High switching capacity 1a/1c 30A power relays

High switching capacity 1a/1c 30A power relays Automation Controls Catalog High switching capacity 1a/1c 3A power relays JT-N RELAYS PCB type FEATURES High switching capacity: 3 A for 1 Form A 2 contact arrangements: 1 Form A or TMP types available

More information

Informative (*Customer to review then remove this page from submitted witness test procedure)

Informative (*Customer to review then remove this page from submitted witness test procedure) WITNESS TEST PROEDURE TEMPLTE National Grid Use Only: Doc. # PR.756..12.16 Publication Date: 12/6/16 Document Sponsor: Neil F. Larake, Retail onnections Policy & Standards Next Scheduled Review: 8/1/17

More information

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry.

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry. Industrial Controls SIRIUS R_* in sizes S00/S0 to S Catalog Add-On IC 0 AO 0 SIRIUS Answers for industry. Controls Contactors and Contactor Assemblies for Switching Motors Price Groups PG B, H / Introduction

More information

Altech Corporation What is a Safety Relay?

Altech Corporation What is a Safety Relay? Altech orporation Since 1984, Altech orporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

Instructions for Tempco Control Enclosure PCM10001 through PCM10004

Instructions for Tempco Control Enclosure PCM10001 through PCM10004 Visionary Solutions for Industry Since 1972 ISO 9001 Certified Temperature Controllers & Sensors Heating Elements Process Heating Systems Instructions for Tempco Control Enclosure PCM10001 through PCM10004

More information

CI-tronic Soft start motor controller

CI-tronic Soft start motor controller Data sheet CI-tronic Soft start motor controller MCI 3, MCI 15, MCI, MCI 30 I-O, MCI 40-3D I-O and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus

More information