1 .1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions Standards and Certifications Catalog Selection Product Selection Single-Phase Aluminum Single-Phase Copper Single-Phase Shielded Aluminum Single-Phase Shielded Copper Three-Phase Aluminum Three-Phase Copper Three-Phase Shielded Aluminum Three-Phase Shielded Copper Accessories Technical Data and Specifications K-Factor Aluminum Copper Page V-T-3 V-T-3 V-T-4 V-T-4 V-T-4 V-T-6 V-T-8 V-T-10 V-T-1 V-T-3 V-T-34 V-T-4 V-T-50 V-T-50 V-T-51 V-T-5 V-T-57 Product Description Note: The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel), refer to Eaton. Types DS-3, DT-3 Ventilated, NEMA enclosure standard Suitable for indoor applications, outdoors when weathershields are also installed Upright mounting only 0ºC insulation system 150ºC rise standard; 115 C or 80 C rise optional Available in single-phase ratings , 600 volts primary (DS-3) Available in three-phase ratings and up to 600 volts primary (DT-3) Application Description NEMA TP-1-00 compliant energy-efficient transformers are specifically designed to meet the energy efficiency standards set forth in NEMA Standards publication, TP-1-00, Guide for Determining Energy Efficiency for Distribution Surveys have shown that the average loading of low voltage dry-type distribution transformers, over a 4-hour period, is approximately 35%. NEMA TP-1 compliant transformers are optimized to offer maximum efficiency at 35% of nameplate rating. The range of products covered by NEMA TP-1-00 are: NEMA TP-1-00 Product Range Voltage Rating Class Dry-Type Rating Liquid Rating Primary voltage Secondary voltage Single-phase Three-phase Single-phase Three-phase Voltage 34.5 kv and below 600V and below that are currently specifically excluded from the scope of NEMA Standard TP-1-00 include: Liquid-filled transformers below 10 Dry-type transformers below 15 AC and DC drives transformers Rectifier transformers designed for high harmonics Autotransformers Non-distribution transformers, such as UPS transformers Special impedance or regulation transformers Regulating transformers Sealed and non-ventilated transformers Machine tool transformers Welding transformers with tap ranges greater than 15% with a frequency other than 60 Hz Grounding transformers Testing transformers Efficiency levels set forth in NEMA TP NEMA TP-1-00 Efficiency Levels Tables of Energy Efficiency NEMA Class 1 Efficiency Levels Dry-Type Distribution Low Voltage (600V and below) Single-Phase Three-Phase Efficiency Efficiency V-T- Volume Commercial Distribution CA E February 013
2 NEMA TP-1 Energy-Efficient.1 Features, Benefits and Functions 60 Hz operation (except as noted) Short-term overload capability as required by ANSI Meet NEMA ST-0 sound levels Meet federal energy efficiency requirements for low voltage dry-type distribution transformers effective as of January 1, 007 Standards and Certifications UL listed Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the Uniform Building Code (UBC), International Building Code (IBC) and California Code Title 4. Volume Commercial Distribution CA E February V-T-3
3 .1 NEMA TP-1 Energy-Efficient Three-Phase Type DT-3 60 Hz NEMA TP-1 Energy-Efficient Copper Windings 480 Delta Volts to 08Y/10 Volts Full Capacity Taps FCAN FCBN Type ºC Temp. Rise Frame Wiring Diagram Weight Lbs (kg) 1 Weathershield Style 15 at +.5% 4 at.5% DT B 80B 50 (114) WS38 V48M8T15CUEE 30 at +.5% 4 at.5% DT B 80B 350 (159) WS38 V48M8T30CUEE 37.5 at +.5% 4 at.5% DT B 80B 415 (188) WS38 V48M8T37CUEE 45 at +.5% 4 at.5% DT B 80B 416 (189) WS38 V48M8T45CUEE 50 at +.5% 4 at.5% DT D 80B 647 (94) WS39 V48M8T50CUEE 75 at +.5% 4 at.5% DT D 80B 643 (9) WS39 V48M8T75CUEE 11.5 at +.5% 4 at.5% DT A 80B 876 (398) WS19 V48M8T1CUEE 150 at +.5% 4 at.5% DT A 80B 1064 (483) WS19 V48M8T49CUEE 5 at +.5% 4 at.5% DT B 1371 (6) WS41 V48M8TCUEE 300 at +.5% 4 at.5% DT B 16 (736) WS4 V48M8T33CUEE 500 at +.5% at.5% DT B 3681 (1671) WS40 V48D8T55CUEE 750 at +.5% 4 at.5% DT E 75A 4891 (1) WS35 V48M8T77CUEE 15 at +.5% 4 at.5% DT B 80B 56 (116) WS38 V48M8F15CUEE 30 at +.5% 4 at.5% DT B 80B 337 (153) WS38 V48M8F30CUEE 45 at +.5% 4 at.5% DT B 80B 446 (0) WS38 V48M8F45CUEE 75 at +.5% 4 at.5% DT D 80B 66 (301) WS39 V48M8F75CUEE 11.5 at +.5% 4 at.5% DT A 80B 914 (415) WS19 V48M8F1CUEE 150 at +.5% 4 at.5% DT A 80B 113 (514) WS19 V48M8F49CUEE 5 at +.5% 4 at.5% DT A 036 (94) WS34 V48M8FCUEE 300 at +.5% 4 at.5% DT A 35 (1056) WS37 V48M8F33CUEE 500 at +.5% 4 at.5% DT A 3681 (1671) WS35 V48M8F55CUEE 15 at +.5% 4 at.5% DT B 80B 349 (158) WS38 V48M8B15CUEE 30 at +.5% 4 at.5% DT B 80B 410 (186) WS38 V48M8B30CUEE 45 at +.5% 4 at.5% DT B 80B 504 (9) WS38 V48M8B45CUEE 75 at +.5% 4 at.5% DT A 80B 818 (371) WS19 V48M8B75CUEE 11.5 at +.5% 4 at.5% DT A 80B 1065 (484) WS19 V48M8B1CUEE 150 at +.5% 4 at.5% DT B 1410 (640) WS34 V48M8B49CUEE 5 at +.5% 4 at.5% DT A 030 (9) WS37 V48M8BCUEE 300 at +.5% 4 at.5% DT E 75A 3041 (1381) WS35 V48M8B33CUEE 500 at +.5% 4 at.5% DT E 75A 4696 (13) WS35 V48M8B55CUEE 1 Weights subject to change. For other ratings or styles not shown, or for special enclosure types (including stainless steel), refer to Eaton. Frame drawings/dimensions information begins on Page V-T-13. V-T-8 Volume Commercial Distribution CA E February 013
4 .6 Transformer Standards, Technical Data and Accessories Standards and Certifications Eaton dry-type distribution transformers are approved, listed, recognized or may comply with the following standards. Engineering Standards Catalog Product Name UL Standard 1 1 UL 5085 replaces UL 506. Applies to Applies to 5. 4 Applies to Applies to Applies to 3. 7 Applies to Applies to Applies to 30. UL/cUL File UL Listed Control cul Energy Efficiency File In addition to the above standards, Eaton dry-type distribution transformers are also manufactured in compliance with the applicable standards listed below. Not all of the following standards apply to every transformer. NEC: National Electrical Code NEMA ST-1: Specialty (C89.1) (control transformers). NEMA ST-0: General-Purpose NEMA TP-1: Guide for Determining Energy Efficiency for Distribution NEMA 50: Enclosures for Electrical Equipment (1000 volts maximum). IEEE C : General Requirements for Dry-Type Distribution and Power (including those with solidcast and/or resin-encapsulated windings). CSA File Insulation System Temp/ºC ANSI C : Terminal Markings and Connections for Distribution and Power ANSI C : Standard Test Code for Dry-Type Distribution and Power CSA C No. 47-M90: Air-Cooled (Dry-Type). CSA C9-M1981: Dry-Type CSA C. No. 66: Specialty CSA 80-94: Maximum Losses for Distribution, Power and Dry-Type NEMA TP-: Standard Test Method for Measuring the Energy Consumption of Distribution NEMA TP-3 Single- Phase Three- Phase Applicable IEC Standard Industrial Control Transformer MTE 5085 E X LR N/A MTK 5085 E X LR N/A Encapsulated Transformer AP 5085 E H N/A AP 1561 E H N/A EP 5085 E H LR N/A EP 1561 E H EV157 LR N/A / 76 5 EPT 5085 E H LR N/A / 76 7 EPT 1561 E H EV157 8 LR N/A MPC 106 E H LR Ventilated Transformer DS E H N/A 6076 DT E H 0 N/A KT 1561 E H 0 N/A N/A V-T-184 Volume Commercial Distribution CA E February 013
5 Transformer Standards, Technical Data and Accessories.6 Catalog Selection General-Purpose, Energy-Efficient, Mini Power Center, Shielded Isolation, Nonlinear, Buck-Boost, Marine Duty Example: S0N11S05A C Prefix Options = CSA labeled ventilated transformer Marine Duty QS = EPM marine (1-Ph encapsulated) LY = EPTM Marine (3-Ph encapsulated) RT = DS-3M marine (1-Ph ventilated) MV = DT-3M marine (3-Ph ventilated) Type S = EP (single-phase encapsulated) Y = EPT (three-phase encapsulated) T = DS-3 (single-phase ventilated) V = DT-3 (three-phase ventilated) P = Mini power center Z = Class 1 Division Groups C and D X = Harmonic mitigating (three-phase ventilated) Nonlinear H = KT-4 (three-phase ventilated) B = KT-9 (three-phase ventilated) N = KT-13 (three-phase ventilated) G = KT-0 (three-phase ventilated) J = KT-30 (three-phase ventilated) A = KT-40 (three-phase ventilated) K = KT-50 (three-phase ventilated) HT = KT-4 (single-phase ventilated) NT = KT-13 (single-phase ventilated) GT = KT-0 (single-phase ventilated) 1 Model number is not used on newly designed/redesigned transformers. Copper windings. 3 Grade 304 stainless steel enclosure (does not imply a NEMA 4X rating). 4 Open type core and coil assembly. 5 Totally enclosed non-ventilated DS-3 or DT /60 Hz. 7 Low sound design. LS47 indicates low sound equal to 47 db; LS4 indicates 4 db. Primary Voltage 13 = 110 x 0 1 = = 10 x 40 9 = 08 7 = 00 5 = 0 3 = 30 4 = 40 0 = 40 x = = = = = = = = = = = = = Export model 54 = 10/08/40/77 Taps D = at +.5%, at.5% E = 1 at +5%, 1 at 5% F = 1 at 10% G = at 5% J = 4 at.5% K = 1 at 10% x at 5% L = at 5% x 4 at.5% M = at +.5%, 4 at.5% N = None R = 1 at +5%, at 5% P = 1 at +5%, at 5% x at +.5%, 4 at.5% T = 1 at +4.%, 1 at 4.% U = 1 at +.5%, 3 at.5% W = 1 at +3.5%, 1 at 3.5% X = at +3.1%, at 3.1% 8 Fungus proof. 9 Certified test report of standard production tests for the specific serial number to be shipped. j Certified sound level report. k CE Marked. l Thermal indicator embedded in center coil. Suffix TT indicates two thermal indicators of different temperature ratings, are installed. m NEMA TP-1 efficient. T S 0 N 11 S 05 A 81 = = = = = = = =1 16 =1.5 0 = A = Buck and boost B = 80 C rise F = 115 C rise P = 115 C rise epoxy 04 = 1/4 06 = 16/3 08 = 4/48 14 = 110/0 1 = = 10 x = 10/40 54 = 17/54 19 = 190Y/110 8 = 08Y/10 9 = 08 5 = 0 delta 31 = 0Y/17 6 = 0 delta/110 midtap = 40 delta/10 midtap 64 = 40Y/139 4 = 40 delta 03 =3 05 =5 06 =6 07 = =9 10 =10 15 =15 1 =.5 5 =5 30 =30 Phase E = Electrostatic shield S = Single T = Three Secondary Voltage 37 = =45 50 =50 75 =75 99 =100 1 = = =167 =5 n 0º phase-shift (used with HMTs). o +15º phase-shift (used with HMTs). p 15º phase-shift (used with HMTs). q 30 phase-shift (used with HMTs). r CSL3 DOE 007 energy-efficient. s NEMA 4X Grade 304 stainless steel enclosure. t Easy install base. BK Grade 316 stainless steel enclosure (does not imply NEMA 4X rating). BL Integral -inch infrared viewing window. BM Integral 3-inch infrared viewing window. BN Integral 4-inch infrared viewing window. BO NEMA Premium Efficient. 0 = 40 x = 40/480 7 = = 380 delta 37 = 380Y/0 34 = 400Y/31 51 = 416Y/40 35 = 440Y/54 6 = 460Y/66 47 = 480Y/77 48 = 480 delta 60 = 600 delta 61 = 600Y/346 4 = = 4160Y/ = = = = = = = = = = 1500 Suffix Options A...Y = 1 CU = SS = 3 ZZ = 4 NV = 5 X = 6 LS = 7 AF = 8 TR = 9 SR = j CE = k T = l EE = m NON = n POS = o NEG = p THR = q E3 = r SS4X = s Z = t S6 = BK I = BL I3 = BM I4 = BN N3 = BO For Eaton s industrial control transformers catalog number selection, see Page V-T-186. Contact your local Eaton sales office for voltage combinations not shown. Use table for catalog number breakdown only. Do not use to create catalog numbers because all combinations may not be valid. Volume Commercial Distribution CA E February V-T-185
6 .6 Transformer Standards, Technical Data and Accessories Three-Phase How to Select Three-Phase Units 1. Determine the primary (source) voltage the voltage presently available.. Determine the secondary (load) voltage the voltage needed at the load. 3. Determine the load: If the load is defined in, a transformer can be selected from the tabulated data If the load rating is given in amperes, determine the load from the chart (below right). To determine when volts and amperes are known, use the formula: Volts Amperes 1.73 = If the load is an AC motor, determine the minimum transformer from the chart at the right Select a transformer rating equal to or greater than the load 4. Define tap arrangements needed. 5. Define temperature rise. Using the above procedure, select the transformer from the listings in this catalog. Three-Phase AC Motors Full Load Amperes Horsepower 08 Volts 30 Volts 380 Volts 460 Volts 575 Volts / Full Load Current in Amperes Three-Phase Circuits Minimum Transformer 1 Voltage If motors are started more than once per hour, increase minimum transformer by 0% When motor service factor is greater than 1, increase full load amperes proportionally. Example: If service factor is 1.15, increase above ampere values by 15% V-T-188 Volume Commercial Distribution CA E February 013
PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer
PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient
More informationS10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S10N06P0P KVA 1PH 10/40V 16/3V Buck Boost Transformer Eaton Corp Catalog Manufacturer Description Weight per unit Product
More information2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers
.5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings
More information2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description
General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................
More information2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description
General-Purpose Encapsulated Transformers.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Transformers Catalog Selection................ Product Selection....................... Single-Phase..........................
More information2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description
General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................
More information2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description
Distribution.5 Contents Description Motor Drive Isolation............ Mini Power Centers Standards and Certifications............... Catalog Number Selection................ Product Selection.......................
More informationP48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 P48G11S05P 5KVA 1PH 480V - 10/40V Mini Power Center Eaton Corp Catalog Number Manufacturer Description Weight per unit
More informationTechnical Data and Specifications. Core and Coil Assemblies
February 2007 Technical Data and Specifications -161 Typical Specifications Mini-Power Centers (3 30 kva) General Furnish and install, single-phase and three-phase general purpose individually mounted
More informationLVGP. Advanced transformers built for the industrial environment. Catalog: LVGP-16C-English. By Micron Power Delivery. Supersedes: LVGP-16B-English
LVGP By Micron Power Delivery Advanced transformers built for the industrial environment Catalog: LVGP-16C-English Supersedes: LVGP-16B-English Table of Contents Low Voltage General Purpose Transformers
More informationDry Type Transformers Full Line Catalog. jeffersonelectric.com
Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production
More informationand cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.
-156 Purpose & Industrial Control Purpose (1000 kva and Below) mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. shall be manufactured
More informationT S 15KVA 1PH 240/480 Transformer
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T2535173S 15KVA 1PH 240/480 Transformer Acme Electric Catalog Number Manufacturer Description Weight per unit Product
More informationGeneral Purpose Transformers
Transformers General Purpose Transformers Standard Units 1P 480 x 240V Primary, 120/240V Secondary.25 1D1N205.50 1D1N505.75 1D1N705 1.0 1D1N001 1.5 1D1N105 2.0 1D1N002 3.0 1D1N003 5.0 1D1N005 7.5 1D1N007
More informationSteps for Selecting the Proper Transformer
SECTION I Page 4 Steps for Selecting the Proper Transformer SINGLE PASE LOADS 1. Determine electrical load A. Voltage required by load. B. Amperes or KVA capacity required by load. C. Frequency in z (cycles
More informationJefferson Electric Inc Product Catalog JE901
Jefferson Electric Inc Product Catalog JE901 Worldwide Products and Services Tradition of Excellence Jefferson Electric has been a pioneer and innovator of magnetic products since 1915. We enjoy a rich
More informationGENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS
GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find
More informationINTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers
INTERNATIONAL TRANSFORMERS Acme Electric s broad selection of CSA energy efficient transformers International Transformers What is CSA C802.2 Compliant? On January 1, 2005, the Canadian Energy Efficiency
More informationBrown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS
SECTION 16461C - DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.1 This section includes design and performance requirements for dry-type transformers rated for use on secondary distribution systems rated 600
More informationPremium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated
Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated Catalog 7400CT1001 2010 Class 7400 CONTENTS Description.............................................
More informationWarehouse Stock Transformers
Warehouse Stock s Warehouse Stock Buck-Boost Application Description and The Buck-Boost has four separate windings, two-windings in the primary and two-windings in the secondary. The unit is designed for
More informationLow Voltage Transformers. Selection Guide
Low Voltage Transformers Selection Guide Special Purpose Transformers Non-Ventilated Transformers For use in contaminated or dust-laden environments, indoor or outdoor. Export Model Transformers Designed
More informationStandards. n Built in accordance with NEMA, ANSI, UL and CSA standards
Buck-Boost 9 0 VA to 10 Applications n A comprehensive line of transformers for low voltage applications. n Economical for stepping voltages up or down n Solve over/under voltage problems efficiently n
More informationCompliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)
Typical Specification 1.2kV Class Energy Efficient Dry-Type Distribution Transformers Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016) Canada 595 Southgate Drive Guelph, Ontario N1G
More informationPower Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers
Power Quality 13 Answering Today s Power Challenges Jefferson Electric is continually updating its product line to remain on the forefront of transformer technology. Electrical harmonics have become a
More informationHPS Universal BUCK-BOOST TRANSFORMERS
BUCK-BOOST TRANSFORMERS Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationGE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class
GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial
More informationWhat is a Transformer?
What is a Transformer? Transformers are completely static electrical devices which convert alternating current from one voltage level to another. General purpose transformers are rated 600 volts and below
More informationBUCK-BOOST TRANSFORMERS
Hammond Power Solutions Inc. Page of Buck-boost transformers represent an economical way to both raise supply voltage caused by line drop or equipment demand on the distribution system; or lower voltage
More informationDry-Type Transformers
Dry-Type Transformers 600 Volt Class Bulletin 7700-99 ISO 9002 Registered 1 Federal Pacific Federal Pacific History During 1987, the Electro-Mechanical Corporation acquired the dry-type transformer division
More informationMGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide
MGM Transformer Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide MGM Transformer Company 5701 Smithway Street Commerce, CA 90040 www.mgmtransformer.com Phone: 323.726.0888
More informationYour Presenters. > Thomas Patzner Product Manager, Low Voltage Transformers. > Marquette University Electrical Engineering. > Apprentice Electrician
Your Presenters > Thomas Patzner Product Manager, Low Voltage Transformers > Marquette University Electrical Engineering > Apprentice Electrician > Low Voltage Transformers - Co-op (Square D Company) (lab
More informationEnergy Efficient Distribution Transformers
Energy Efficient Distribution Transformers Established in 1917, Hammond Power Solutions Inc. (HPS), is an industry leader in magnetic transformer design and development. With our headquarters in Guelph,
More informationTransformer Questions & Answers
Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed
More information75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R
75 kva Isolation Transformer 480V Delta Primary 208V Delta Secondary NEMA 3R Part #: MTDOE163P480D75KVA208DN3R Page: 1 The MTDOE163P480D75KVA208DN3R 480D 3 Phase Energy Efficient Isolation Transformer
More information1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R
1.5 kva Single Phase Transformer 120V Primary Voltage 277V Secondary Voltage NEMA 3R Part #: MT120V1.5KVA277V Page: 1 The MT120V1.5KVA277V 120V 1 Phase Energy Efficient Transformer from Larson Electronics
More informationTransformer Questions & Answers
Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed
More information225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R
225 kva Autotransformer 240V Delta Primary Voltage 220V Delta Secondary Voltage NEMA 3R Part #: MTATX3P240D225KVA220DN3R Page: 1 The MTATX3P240D225KVA220DN3R 240D 3 Phase Energy Efficient Autotransformer
More information80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase
80 kva Isolation Transformer 480V AC Primary 20V AC Secondary NEMA 3R Single Phase Part #: MTDOE161P480V80KVA20VN3R The MTDOE161P480V80KVA20VN3R 480V AC 1 Phase Energy Efficient Isolation Transformer from
More information10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R
10 kva Transformer 480V Primary Voltage 208V Secondary Voltage Single Phase NEMA 3R Part #: MTATX1P480V10KVA208VN3R Page: 1 The MTATX1P480V10KVA208VN3R 480V 1 Phase Energy Efficient Encapsulated Transformer
More informationFull Line Product Catalog
Full Line Product Catalog TC Table of Contents Dry-Type Distribution Transformers Transformer Questions and Answers 6-13 Enclosure Definition 13 Steps in Transformer Selection 14-17 Construction Features
More informationLow Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned
Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design
More information500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R
500 kva Isolation Transformer 480V Delta Primary 400Y/231 Wye Secondary NEMA 3R Part #: MTDOE163P480D500KVA400Y.231N3R Page: 1 The MTDOE163P480D500KVA400Y.231N3R 480 V Delta 3 Phase Energy Efficient Isolation
More informationStraight Isolation - Hard Wired (169 Series)
LINE ISOLATION TRANSFORMERS (115V to 115V) Primary 115C, 60 Hz., Secondary 115C Electrostatic shield between primary & secondary Connection by flexible leads, 8" minimum length Perfect for circuit isolation
More information500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor
500 kva Dry-type Isolation Transformer - 13200V-Delta to 208Y/120V 3PH - NEMA 1/Indoor Part #: MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Page: 1 The MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Dry-type Isolation
More information7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz
7.5 kva Isolation Transformer 460V Primary 230V Secondary NEMA 3R Single Phase 50/60 Hz Part #: MTISX1P460V7.5KVA230VN3R50.60HZ Page: 1 The MTISX1P460V7.5KVA230VN3R50.60HZ 460V 1 Phase Energy Efficient
More informationHarmonic mitigating transformers. Energy savings through harmonic mitigation
Harmonic mitigating transformers Energy savings through harmonic mitigation Harmonic mitigating transformers Today s issues and needs Eaton s Harmonic Mitigating Transformer (HMT) As our world becomes
More information75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R
75 kva Isolation Transformer 4160V Delta Primary Voltage 480Y/277 Secondary Voltage NEMA 3R Part #: MTISX3P4160D75KVA480Y.277N3R Page: 1 The MTISX3P4160D75KVA480Y.277N3R 4160D 3 Phase Energy Efficient
More informationDescription & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...
SECTION BUCK-BOOST TRANSFORMERS A simple and economical way to correct offstandard voltages... from 95 to 500 volts; single and three phase, in sizes up to 60 kva. Simplified buck-boost rating charts make
More informationFull Line Product Catalog
Full Line Product Catalog E L E C T R I C A L TABLE OF CONTENTS SECTION 1 SECTION 2 SECTION 3 Dry-Type Distribution Transformers Transformer Questions & Answers... 6-10 Selection Steps... 11-12 Construction
More informationHarmonic mitigating transformers. Energy savings through harmonic mitigation
Harmonic mitigating transformers Energy savings through harmonic mitigation Harmonic mitigating transformers Today s issues and needs Eaton s harmonic mitigating transformer (HMT) As our world becomes
More informationUBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations 1.2 Description.1 UBC requirements for Substation Transformers. 2.0 MATERIAL AND DESIGN REQUIREMENTS
More information15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R
15 kva Isolation Transformer Single Phase 208V Primary 120/240V Secondary NEMA 3R Part #: MT20815KVA240.120 Page: 1 The MT20815KVA240.120 208V 1 Phase Energy Efficient Isolation Transformer from Larson
More informationSECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE
SUBSTATION TRANSFORMERS DRY-TYPE PART 1 GENERAL 1.01 1.02 1.03 1.04 SCOPE The Contractor shall furnish and install the primary and/or secondary substation transformers as specified herein and as shown
More information5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R
5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R Part #: MT-ISX-FP-1P-115V-5KVA-230V-N3R Page: 1 The MT-ISX-FP-1P-115V-5KVA-230V-N3R 115V 1 Phase Energy
More informationAcme Electric Full Line Product Catalog
Acme Electric N85 W12545 Westbrook Crossing Menomonee Falls, WI 53051 800.334.5214 acmepowerdist.com Acme Electric Full Line Product Catalog Full Line Product Catalog Today, Actuant Electrical provides
More informationDescription. Features and Benefits
KA-108 The General Electric Type KA-108 Bushing Potential Device is a reliable, safe, economical voltage transforming device for the operation of instruments and relays from high-voltage circuits, 115
More informationLiquid-Filled Transformers
Liquid-Filled Transformers Custom Transformers at Standard Prices NIAGARA TRANSFORMER CORP. Induction Furnace Transformer Cycloconverter Rectifier Duty Transformer Arc Furnace Transformer Full Range of
More information2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives
.0 Volume 6 Solid-State Control CA0800007E March 05 www.eaton.com V6-T-47 .0 Adjustable Frequency Drives Overview What Are Harmonics? Take a perfect wave with a fundamental frequency of 60 Hz, which is
More informationULTRA-K Series 600K - he
5 kva 500 kva ULTRA-K Series 600K - he High Efficiency K-Rated Power Conditioning Transformers Designed to be used with linear or non-linear loads. Applications: Audio / Video Recording Equipment IT Systems
More informationSINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL
SINGLE PHASE INSTRUCTION MANUAL DIAGRAM D This manual applies to all single-phase buck & boost transformers sold by Larson Electronics. Please refer to the connection diagram on pages 4-6 for properly
More informationDry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION
NON-LINEAR TRANSFORMER PRESENTATION 1 PROBLEM: HARMONICS CAUSE EXCESSIVE TRANSFORMER HEATING Increased Losses Proximity Skin Effect Stray Losses Circulating Effect Triplen Harmonics Add in Neutral Increased
More informationDONGAN ELECTRIC MANUFACTURING CO.
DONGAN ELECTRIC MANUFACTURING CO. Electric Manufacturing Co. 2987 FRANKLIN DETROIT, MI 48207 800.428.2626 313.567.8500 Spec Tech Industrial 203 Vest Ave Valley Park, MO 63088 FAX 313.567.8828 www.dongan.com
More informationGeneral Description & Features Selection Charts Definition of Terms... 42
SECTION NON-LINEAR LOAD ISOLATION TRANSFORMERS Special winding techniques minimize eddy current losses. A double sized neutral handles excessive neutral currents. UL Listed for K Factor Loads 4, 1 & 20.
More informationSECTION TRANSFORMERS
SECTION 16460 - TRANSFORMERS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Section
More informationK Factor Power Transformers
Ashley-Edison AsiaElectricTransformers (UK) K Factor Power Transformers DTKF series Low Voltage Dry Type K Factor Power Transformers AET-DTKF-2004-01: Page 1 Asia Electric Transformers, Entrepreneur Business
More informationProduct Data Bulletin
Product Data Bulletin Application Tables and Wiring Diagrams Sorgel Buck and Boost s Bulletin No. 7414PD9301 Monroe, NC, U.S.A. (Formerly B-B2R1 10/84) SINGLE PHASE Buck and Boost transformers are insulating
More informationCONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI
GENERAL: The scope of this document is to provide instruction for the installation and testing of Medium Voltage, 3 Phase, Pad Mounted Transformers installed at the University of Missouri. Preferred transformers
More informationPURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS
PURCHASE SPECIFICATIONS OF 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS SPECIFICATION NO. : OR12423 REVISION NO. : Rev 00 DATE : 01.03.2011 DISTRIBUTION : PI - 4 copies O/C - 1 copy PREPARED BY
More informationSWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)
SWF DV/DT Solutions Sinewave Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Does your application use variable frequency drives for improved
More informationDrive Isolation Transformers
Drive Isolation Transformers The Acme Drive Isolation Transformers are specifically designed to accommodate the special voltages and kva sizes unique to AC and DC motor drive applications. DRIVE ISOLATION
More informationPower-Sure 700. Technical Data TD158001EN. Contents
Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications...
More informationUNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1
GENERAL: The scope of this document is to provide instruction for the installation and testing of Medium Voltage, 3 Phase, Pad Mounted Transformers installed at the University of Missouri. Preferred transformers
More informationPower Processor - Series 700F 10KVA to 150KVA
Power Processor - Series 700F 10KVA to 150KVA Power Conditioning and Regulation for Commercial & Industrial Equipment General Specifications PART 1 - GENERAL 1.1 DESCRIPTION This specification defines
More informationNon-Submersible Industrial Pressure Transducer
Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316
More information3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays
.6 Control Relays and Timers Product Overview Catalog Number Selection D9, D96 and D99 Series Description D9 = Hockey puck D96 = Compact D99 = DIN rail Contents D 9 2 5 A M D 2 Output Voltage 1 = 2 60
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationBuck-Boost Transformers
Buck-Boost Transformers Buck Boost transformers are the ideal solution anytime a line voltage change in the 5-15% range is required in single phase or three phase applications. Proper voltage is critical
More informationPowerGard Series C 18-Pulse Enclosed Drive Controllers
PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive and power quality solutions PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive
More informationMGM Transformer Company
MGM TRANSFORMER COMPANY Special Design Dry Type Transformers Liquid Filled and Dry Type Substation Transformers Liquid Filled and Dry Type Drives Isolation Transformers 600V Class General Purpose Transformers
More informationVIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs
VIRGINIA TRANSFORMER CORP Individual solutions from a global perspective Drive & Rectifier Transformersrs Oil Drilling Paper Mill Virginia Transformer Commitment to our Customers Industry s Shortest Production
More informationLoad Isolation Transformers
4 Non-Linear Load Isolation Transformers Section Special winding techniques minimize eddy current losses. A double sized neutral handles excessive neutral currents. UL Listed for K Factor Loads 4, 13 &
More informationMotor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87
Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................
More informationSECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL
PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. a.
More informationDTS ISOLATION TRANSFORMER SPECIFICATIONS
1.1 Scope of Work: DTS ISOLATION TRANSFORMER SPECIFICATIONS The DTS transformers shall be designed to supply isolated power to sensitive computer based equipment. The DTS units will meet or exceed the
More informationINSTALLATION, OPERATION AND MAINTENANCE GUIDE
INSTALLATION, OPERATION AND MAINTENANCE GUIDE FOR INDOOR/OUTDOOR SINGLE PHASE ENCAPSULATED TRANSFORMERS Indoor/Outdoor Encapsulated Transformers The pictures used in this guide are only a representation
More informationLow Pass Harmonic Filters
Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power
More informationTitle Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)
Discipline Engineering Standard NSW Category Electrical Title Substation Auxiliary Transformer from Rectifier Transformer Secondary Reference Number PDS 01 (RIC Standard: EP 05 00 00 01 SP) Document Control
More informationPRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)
PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian) 1.0 General This specification covers the electrical characteristics and
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationCross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92
Cross Flow Fans Additional Information Technical Reference F-1 General Information G-1 Introduction E-85 MF Series E-88 MFD Series E-92 E-84 ORIENTAL MOTOR GENERAL CATALOG 23/24 Cross Flow Fans Cross flow
More informationFederal Pacific Engineered and Specialty Transformer Catalog
Federal Pacific Engineered and Specialty Transformer Catalog Federal Pacific History In 1987, Electro-Mechanical Corporation acquired the dry-type transformer division of Federal Pacific Electric in Des
More informationWAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)
WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) 1 PART 1: GENERAL This section describes materials and installation requirements for low voltage
More informationArild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems
Arild Furnes,ATPA OGP/Petrobras workshop, 22.09.09 Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems September 24, 2009 Slide 1 Transformers for Ships and Offshore -
More informationS. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)
S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013) 1.0 GENERAL 1.1 This specification covers the electrical and mechanical
More informationStraight Isolation - Plug In (171 Series)
Straight Isolation - Plug In (171 Series) LINE ISOLATION PLUG & RECEPTACLE TRANSFORMERS (115V to 115V) Primary 115C, 50/60 Hz., Secondary 115C Electrostatic shield between primary & secondary. Hi-pot tested
More informationChapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5
Applied Grounding and Bonding Paul Dobrowsky Member NEC Panel 5 1 Introduction This presentation is a representative sample from the following Chapters of Applied Grounding and Bonding. Chapter 1, Introduction
More informationAF91 Adjustable Frequency Drives Series B
Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based
More informationBUCK-BOOST TRANSFORMERS
Where Are Buck-Boost Transformers Used? A typical buck-boost application is 120 volts in, 12 volts out for low voltage lighting or control circuitry. In most applications, this low voltage transformer
More informationIsolation Transformer Series
Isolation Transformer Series Unit Shown With Options ITS Series - Isolation Transformer Series The La Marche Isolation Transformer Series (ITS) is designed for installation in industrial and harsh environment