and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.
|
|
- Gerald Dickerson
- 5 years ago
- Views:
Transcription
1 6-4 Freedom Pump Panels Circuit reaker R Enclosure / -Phase Magnetic / Interchangeable eater OLR These ECN Irrigation Pump Controllers feature the Cutler-ammer Freedom Series starters. They have a AND/OFF/AUTO selector switch Voltage Max. hp 0/60 z 0 7-/ / Circuit reaker Type MCPE 7A MCPE A MCPE 0A MCPE A MCPE 7A MCPE A MCPE 0A MCPE 0A MCPE 0A MCPE 00A MCPE 00A 4 MCP 0A MCP 0A MCP 0A MCP 400A MCP 0A MCP 400A 6 MCP 600A MD 800A MCP 600A MD 800A and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-. Narrow idth Standard idth * Catalog Number Catalog Number ECNAC-E4 AD-E4 AE-E4 ECNCA-E4 CAC-E4 CAD-E4 CAE-E4 ECNAF-E4 CAF-E4 7 ECNAC AD AE ECNCA CAC CAD CAE ECNAF CAF ECNAG CAG ECN4A 4CA ECNAJ AK CAJ CAK ECN6AL 6AM 6CAL 6CAM ECN7AU 7AU 7CAU 7CAU ers do not include heater packs. Select carton of heater packs. eater pack selection, Page 4-4. If branch circuit protective device is 4A or greater, C0FR fuse kit (panel mounted) may be required for control circuit protection per NEC Does not include top conduit hubs. ubs are available in kit form see Page 6-9. To order without the START pushbutton, add mod code P6. Consult factory in the event ground fault protection is required. Supply hp, voltage, FLA and whether motor is design E or not when ordering the starter. UL UL Listed File #E49, Guide NLDX. For Other Volts and ertz Applications February 999 For other than listed volts and hertz, select required controller by catalog number and replace the magnet coil alpha designation, 9th or 0th digit in catalog number with proper code suffix from table below. Example: For 600V 60 z coil, change ECNCAC to ECNDAC. Coil Volts and ertz 0/60 or 0/0 40/60 or 0/0 480/60 or 440/0 600/60 or 0/0 08/60 Code Suffix A C D E Panel Space Panel Position (See Sketches at Right) Dimensions in Inches (mm) idth eight Narrow. (40) 6.0 () Standard 4 Oversize A 8. (6) 8. (6) 0.0 (4).0 (8).0 (8).0 (79) 6.0 (660) 9.0 (99).0 (9).0 (0) 9.0 (99) 9.0 (99) Panel Space Pos. A Pos. Space is between disconnect switch or circuit breaker and starter. s 4 Dimensions Page -6 Accessories, Kits Pages - -9 *Prices Consult Factory Modifications Pages -6 - Discount Schedule CD-C PG..0.T.E
2 February 999 Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema Modification Codes (See Pages -6 to -) Class Page 0 - Contactors Reversing Contactors FVNR er, Non-combination Reversing, Non-combination FVNR Non-combination, with CPT Single-Phase FVNR (Freedom Only) Combination with Disconnect Switch Reversing, Combination with Disconnect Switch Combination with Disconnect Switch, with CPT -9 - Combination with MCP - - Reversing, Combination with MCP Combination with MCP with CPT -6 - Multispeed S Non-combination Multispeed S CT or VT Non-combination -9 - Multispeed S C Non-combination Multispeed with Disconnect Switch, S Multispeed with Disconnect Switch, S CT or VT Multispeed with Disconnect Switch, S C Multispeed with MCP, S Multispeed with MCP, S CT or VT Multispeed with MCP, S C Autotransformer, Non-combination Autotransformer, with Disconnect Switch Autotransformer, with MCP Part-inding, Non-combination Part-inding, with Disconnect Switch Part-inding, with Circuit reaker Y-D, Open Transition, Non-combination Y-D, Open Transition, with Disconnect Switch Y-D, Open Transition, with Circuit reaker -8 - Y-D, Closed Transition, Non-combination Y-D, Closed Transition, with Disconnect Switch -6 - Y-D, Closed Transition, with Circuit reaker Std idth Pump Panel, with Disconnect Switch 6- - Std idth Pump Panel, with MCP Autotransformer Pump Panel, Disconnect Switch 6 - Autotransformer Pump Panel, MCP 64 - Part-inding Pump Panel, Disconnect Part-inding Pump Panel, Circuit reaker Duplex, Non-combination Duplex, with Disconnect Switch Duplex, with MCP -7 Consult factory. A - - C - D - E - F - A - - C - D - E - F - Cover Control (ers Only) Number of Poles (Contactors Only) Coil Voltage and/or Control Transformers (See Charts elow) None 0A/0V R 0A/600V R 60A/0V R 60A/600V R 00A/0V R None A 7A A 0A 0A Disconnect Fuse Clip Ratings G - - J - K - L - M - 00A/600V R 00A/0V R 00A/600V R 400A/0V R 400A/600V R 600A/0V R MCP or reaker Ratings G - 00A - 0A J - 0A K - 400A L - 600A M - 800A N - 600A/600V R P - 800A/600V L Q - 00A/600V L R - 600A/600V L S - 000A/600V L T - by N - 000A - A P - 00A 6-7A Q - 000A 7 - A R - 000A 8-0A T - by 9-0A I - 00A Use for s 0, MCP 600V applications only. Enclosure Types - Type General Purpose - Type R Rainproof - Type 4 atertight (Painted Steel) 4 - Type 4X atertight (Stainless Steel) - Type 4X Corrosion (nonmetallic) (Section 9) 6 - Type 7/9 olted azardous Location (Section 8) 7 - Type 7/9 Threaded azardous Location (Section 8) 8 - Type Dust-Tight 9 - Type Dust-Tight with Safety Door Interlock A Magnet Coil Codes (System Voltage) Code Magnet Coil Code Magnet Coil Code Magnet Coil Control Power Transformer Codes (System Voltage) Code Primary Secondary Code Primary Secondary A C D E G J 0/60 0/0 40/60 0/0 480/60 440/0 600/60 0/0 08/60 0/0 77/ /60 K L M P Q R S T 40/0 80/0 4/0 V DC 4V DC 48V DC V DC 4/60 hen control power transformer modification codes (C C) are used or when starter class includes CPT (i.e. ECN07, 8) see chart to the right for system voltage code. U V X Y Z 4/0 /0 48/ /60 48/0 y C D E L M Q R 40/480 0/440 ired for 40V 40/480 0/440 ired for 480V 600/60 0/0 08/60 77/60 80/0 4/0 08/60 40/480 0/440 ired for 40V 0/60 0/0 0/60 0/0 0/60 0/0 0/60 0/60 0/0 0/0 4 4 S T U V X Y Z 40/480 0/440 ired for 480V 600/60 77/60 80/0 4/0 40/480/600 ired for 480V 40/480/600 ired for 480V y PG..0.T.E
3 February 999 Freedom ers -Phase Magnetic / Interchangeable eater OLR / 600V Maximum -9 0 Cat. No. AN6N0AC Cat. No. AN6DN0A Enclosed er Cat. No. ECN0CA-PP4 Rated ers Features Designed specifically for use in applications requiring ratings. ers meet or exceed standards ICS -99. imetallic Ambient Compensated Overload Relays available in three basic sizes covering applications up to 900 hp reducing number of different contactor/ overload relay combinations that have to be stocked. These overload relays feature: Selectable Manual or Automatic Reset operation. Interchangeable heater packs adjustable ±4% to match motor FLA and calibrated for.0 and. service factors. eater packs for smaller overload relay will mount in larger overload relay useful in derating applications such as jogging. Load lugs built into relay base. Single-phase protection, Class 0 or Class 0 trip time. Overload trip indication. Electrically isolated NO-NC contacts (pull RESET button to test). Long life twin break, silver cadmium oxide contacts provide excellent conductivity and superior resistance to welding and arc erosion. Generously sized for low resistance and cool operation. Designed to,000,000 electrical operations at maximum hp ratings up through hp at 600V. olding circuit contact(s) supplied as standard: s 00 have a NO auxiliary contact block mounted on righthand side (on 00, contact occupies 4th power pole position no increase in width). s 6 7 have a NO/NC contact block on top left. 8 has a NO/NC contact block on top left back and a NO on top right back. Steel mounting plate standard on all open type starters. ired for separate or common control. (All coil voltages 0V or less are wired for separate control as standard.) Typical iring Diagrams Three-Phase and Single-Phase Applications L L L A Separate Control Remove ire c when it is supplied. c Connect separate control lines to the No. Terminal on T T T the remote pilot T T T device and Terminal 96 on the overload relay. A A L L L A A Separate Control Remove ire c when it is supplied. Connect separate control lines to the No. Terminal on T T T the remote pilot T T T device and Terminal 96 on the overload relay. c Remote Pilot Devices ire Control Not for Use with Auto Reset OL Relays ire Control hen more than one pushbutton station is used, omit Connector A and connect per sketch. 00 A Remote Pilot Devices ire Control Not for Use with Auto Reset OL Relays ire Control hen more than one pushbutton station is used, omit Connector A and connect per sketch. s 0, and A L T L T Field Conversion to -Phase, Add Dotted Connections T T L T L T Field Conversion to -Phase, Add Dotted Connections T T PG..0.T.E
4 February 999 Freedom and Advantage Pump Panels -Phase Magnetic / Irrigation Pump Control Circuit Switch or MCP Circuit reaker 6- Table of Contents Page Freedom Pump Panels Vacuum Pump Panels Advantage Pump Panels Optional Features R with Cutler-ammer er R Enclosure, Narrow, with Cutler-ammer, er The irrigation pump controllers are combination starters with accessories and modifications designed to meet the particular requirements of the irrigation, pumping and oil well industries. The enclosure is R to provide weathertight protection and is available in several sizes, depending on the customer s control or control option requirements. The disconnect, contactor and overload relay are the same as used in Freedom Series and Advantage combination starters. In Freedom Series versions, this includes the innovative overload feature that allows conversion from Class 0 to Class 0 by merely inserting different heater packs. These controllers are available in standard full voltage as well as reduced voltage configurations, with vacuum contactors as well as the standard electromechanical contactors. R Part inding Pump Panel, PG..0.T.E
5 February 999 Technical Data Freedom 4- Coil Data Notes P.U. = Pick-up time is the average time taken from closing of the coil circuit to main contact touch. D.O. = Drop-out time is the average time taken from opening of the coil circuit to main contact separation. Cold = Coil data with a cold coil. ot = Coil data with a hot coil. All data is based on a standard contactor with no auxiliary devices and a 0V AC or 4V DC magnet coil. Coil data has a ±% range depending on the application, therefore specific data may vary. Standards and Certifications (Contactors and ers) Standard: Designed to meet or exceed UL,, IEC, CSA, VDE and S. UL listed: UL File #E49, Guide #NLDX Open and, 4, Enclosed CSA Certified: CSA File #LR, Class #04 Open and Enclosed IEC: IEC , s 6 8; IEC 8; IEC 947 Pending Electrical Life AC- and AC-4 Utilization Categories Life Load Curves Cutler-ammer s Freedom Series contactors have been designed and manufactured for superior life performance in any worldwide application. All testing has been based on requirements as found in and UL standards and conducted by Cutler-ammer. Actual application life may vary depending on environmental conditions and application duty cycle. Utilization Categories AC- Non-inductive or slightly inductive loads, such as resistance furnaces and heating. AC- ing of slip-ring motors. AC- Squirrel cage motors; starting, switching off motors during running. AC-4 Squirrel cage motors; starting, plugging, inching or jogging. NOTE: AC- tests are conducted at rated device currents and AC-4 tests are conducted at six times rated device currents. All tests have been run at V, 60 z. Contactor Choice Decide what utilization category your application is and choose the appropriate curve. Locate the intersection of the life-load curve of the appropriate contactor with the applications operational current (Ie), as found on the horizontal axis. Read the estimated contact life along the vertical axis in number of operational cycles. Operations Operations 00,000,000 0,000,000,000,000 00,000 00,000,000 0,000,000,000,000 00, Table of Contents Page Freedom Freedom eater Pack Selection Advantage Advantage Overload Settings Freedom IEC Control Power Transformer Selection AF Vacuum reak Ampere Rating of AC s reak Amperes AC- Load Life s 00, 480V 60 z reak Amperes AC-4 Load Life s 00, 480V 60 z 000 0,000 PG..0.T.E
6 4- Technical Data Freedom February 999 Contactor Catalog Number/ 00 0 Configuration Number of Poles Auxiliary Contacts, Standard Add-On Auxiliary Contacts,, 4 4th Pole NO () Top (4) or Side (4), Side NO () Top (4) or Side (),, 4, Side NO () Top (4) or Side (),, 4, Side NO () Top (4) or Side () Frame 4 mm 4 mm 6 mm 6 mm 90 mm Continuous Ampere Ratings (I) 9A 8A 7A 4A 90A Maximum orsepower (hp) -Phase V 0V / 7-/ 7-/ -Phase 00V 0V V 7V AC Magnet Coil Data Pick-Up Volts Cold Pick-Up Volts ot Pick-Up Voltamperes Pick-Up atts Sealed Voltamperes Sealed atts Drop-Out Volts Cold Drop-Out Volts ot Maximum Operation Rate Ops/our Pick-Up Time (ms) Drop-Out Time (ms) Coil Operating Range % of Rated Voltage -/ -/ % 46%, % 46%,000 7-/ 7-/ % 0%, % 0%, , Side NO () Left Side (4) or Right Side () % 76% % % 7,00 4 -% to +0% -% to +0% -% to +0% -% to +0% -% to +0% DC Magnet Coil Data For DC Magnet Coils (and coil data), see Accessories, Page -7. Operating Temperature Maximum Operating Altitude (ft.) Mechanical Life Electrical Life (480V/60 z) AC- AC-4 ire Range Power Terminals Control Terminals -0 to 6 C 0,000,000 4,000,000 90,000 6 stranded, 4 solid Cu 6 stranded, 4 solid Cu -0 to 6 C 0,000,000,000,000 8, stranded, 0 4 solid Cu 6 stranded, 4 solid Cu -0 to 6 C 0,000,000,000,000 88, stranded or solid Cu 6 stranded, 4 solid Cu -0 to 6 C 0,000,000,00,000 4 (upper) and/or 6 4 (lower) stranded or solid Cu 6 stranded, 4 solid Cu -0 to 6 C,000 Contact Kit Part Number None None Auxiliary Contact Rating A600, P00 0,000 0,000 /0 4 Cu 6 stranded 4 solid Cu PG..0.T.E
7 i-4 Enclosed Control General Information February 999 Enclosure Types Enclosures provide mechanical and electrical protection for operator and equipment. rief descriptions of the various types of enclosures offered by Cutler-ammer are given below. See Standards Publication No. 0 for more comprehensive descriptions, definitions and/or test criteria. Type (Conforms to IP40) for Indoor Use Suitable for most applications where unusual service conditions do not exist and where a measure of protection from accidental contact with enclosed equipment is required. Designed to meet tests for rod entry and rust resistance. Enclosure is sheet steel, treated to resist corrosion. Depending on the size, knockouts are provided on the top, bottom and sometimes on the side. R Type R (Conforms to IP) for Outdoor Use Primarily intended for applications where falling rain, sleet or external ice formations are present. Gasketed cover. Designed to meet tests for rain, rod entry, external icing and rust resistance. Enclosure is sheet steel, treated to resist corrosion. Depending on the size, a blank cover plate is attached to the top (for a conduit hub) and knockouts are provided on the bottom. Cover-mounted pilot device holes are provided and covered with hole plugs. Type 4 (Conforms to IP6) for Indoor or Outdoor Use Provide measure of protection from splashing water, hose-directed water and wind blown dust or rain. Constructed of sheet steel with gasketed cover. Designed to meet tests for hosedown, external icing and corrosion protection. Enclosure has two watertight hubs (power) installed top and bottom of one control hub installed in bottom depending on size. Cover-mounted pilot device holes are provided and covered with hole plugs. 4X Type 4X (Conforms to IP6) for Indoor or Outdoor Use Provide measure of protection from splashing water, hose-directed water, wind blown dust, rain and corrosion. Constructed of stainless steel with gasketed cover. Designed to meet same tests as Type 4 except enclosure must pass a 00-hour salt spray corrosion resistance test. 7 & 9 olted Type 7 for azardous Gas Locations For use in Class I, Group C or D indoor locations as defined in the National Electrical Code. Type 7 enclosures must withstand the pressure generated by explosion of internally trapped gases and be able to contain the explosion so that gases in the surrounding atmosphere are not ignited. Under normal operation, the surface temperature of the enclosure must be below the point where it could ignite explosive gases present in the surrounding atmosphere. Designed to meet explosion, temperature and hydrostatic design tests. PG..0.T.E
NEMA Size 1 Cat. No. CN55DN3AB
-80 Contactors and Contents Description Product Family Overview Page Product Description....... -78 Features................ -78 Standards and Certifications........... -78 Selection.............. -79
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationNEMA Contactor and Starter Specifications
Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental
More informationMotor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87
Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationMichigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE
PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationAuxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)
Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,
More informationFDM Medium Voltage Controller
1-1 LMR PLUS Product Description For over 50 years, EATON Corporation has been the industry leader in Medium Voltage Motor Control. The FDM Medium Voltage Fire Pump Controller is based on the AMPGARD controller
More informationECL03B1AAA 20A 120V Lighting Contactor
80 South Street 7-7, TX Nacogdoches Phone: --71 Fax: -0-8 L01 0 V Lighting ontactor aton orp Number L01 Manufacturer aton orp escription Lighting ontactor, lectrically eld; Pole; 77/80 V (Filament Lamp),
More informationAC Magnetic Starters (GE)
AC Magnetic Starters (GE) Description of Operation With Local or Remote Start-Stop Selector Switch (LVR) Control Starting Stopping Restarting Turning the selector switch to START energizes M and starts
More informationS&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)
Outdoor Transmission (69 kv through 230 kv) Detailed Functional Specification Guide 1.0 GENERAL 1.01 The circuit-switcher shall conform to the following specification. 1.02 The circuit-switcher shall be
More informationPKZ 2 Manual Motor Protectors Technical Data
08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3
More informationIGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards
APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationIPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection
IPS INTELLIGENT PUMP STARTER With TM Smartstart Ø & Ø, 0/60 Hz, 20~600 VAC, /~00HP Integrated electronic pump protection overload Power metering and data logging options Motor Protection Key dealer yr.
More information1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.
Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......
More informationXT IEC Power Control Miniature Controls
Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)
More informationUtilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms
controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0
More informationItem Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series
ABB Contactors Fits 35mm DIN rail Touch Safe Design Compact Design Captive Terminal Screws Built in surge protection (AF series only) Magnetic coil (AE series only) Electronically controlled coil (AE series
More informationBlock Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4
/0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors
More informationPowerGard Series C 18-Pulse Enclosed Drive Controllers
PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive and power quality solutions PowerGard Series C 18-Pulse Enclosed Drive Controllers Combining adjustable speed drive
More informationSUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand
More informationPANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer
PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient
More informationT S 15KVA 1PH 240/480 Transformer
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T2535173S 15KVA 1PH 240/480 Transformer Acme Electric Catalog Number Manufacturer Description Weight per unit Product
More informationUS Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)
4 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact Footprint Superior
More informationAC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.
Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationS10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S10N06P0P KVA 1PH 10/40V 16/3V Buck Boost Transformer Eaton Corp Catalog Manufacturer Description Weight per unit Product
More informationCast Iron Junction Boxes
Cast Iron I. Purpose of Enclosure Enclosures are used to protect personnel against accidental contact with enclosed electrical devices or connections and to protect the enclosed devices or connections
More informationVariable Transformers Product Design & Engineering Data
Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,
More informationHeavy Duty Safety Switches
eavy uty Safety Switches 240 Volt Class 110 Visible blade heavy duty safety switches are designed for application where maximum performance and continuity of service are required. All heavy duty safety
More informationFor Immediate Delivery call KMParts.com at (866)
Return To MAIN INDEX Magnetic Contactors, Overview / Contactors DIL...M Contactors AC Operated AC Operated, Reversing DC Operated AC/DC Operated, DC Hp ratings / /6 /8 / Starters DIL Universal Contactors
More informationPage 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.
Page -2 Page - DIRECT-ON-LINE STARTERS Motor ratings up to 9A 0V in IEC AC duty General use up to 6A / motor rating up to 2A 600V per UL/CSA Versions with Start-Stop/Reset buttons or Reset button Versions
More informationPosiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC
More informationAF91 Adjustable Frequency Drives Series B
Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based
More informationSIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV
Certificate Number 20081124 E29197A Page 1 of 8 Report Reference E29197, 1974 September 17 Issue Date 2008 November 24 Issued to: This is to certify that representative samples of SIEMENS ENERGY & AUTOMATION
More informationSteps for Selecting the Proper Transformer
SECTION I Page 4 Steps for Selecting the Proper Transformer SINGLE PASE LOADS 1. Determine electrical load A. Voltage required by load. B. Amperes or KVA capacity required by load. C. Frequency in z (cycles
More informationAGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.
AGUB Instrument and Meter Enclosures Furnished with aluminum body and solid or window cover. Class I, Division 1 and, Groups B, C, D Application To pull or splice wires and/or to mount and enclose electrical
More informationPosiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationMicro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13
Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC
More information2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers
.5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings
More information2.1. Product Description
.1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................
More informationGENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS
GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find
More informationTeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7
Presentation Thermal-magnetic motor circuit-breakers types GV, GV and GV7 GV-ME, GV-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control
More informationTable of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35
Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff
More informationINTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers
INTERNATIONAL TRANSFORMERS Acme Electric s broad selection of CSA energy efficient transformers International Transformers What is CSA C802.2 Compliant? On January 1, 2005, the Canadian Energy Efficiency
More informationProtection components
General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the
More information3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e
FIGURE 12-1 Basic relay construction. FIGURE 12-2 Shading coil in AC relays. 1 FIGURE 12-3 Contactor coil and shaded pole stators. FIGURE 12-4 Magnetic motor starter. 2 FIGURE 12-5 Thermal overload devices.
More informationSPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK
SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK PART 1.0 GENERAL 1.1 SCOPE A. This specification contains the minimum requirements for the design, manufacture and testing of a UL listed,
More information1.3. Pushbuttons and Indicating Lights.
.3 Pushbuttons and Indicating Lights Pushbutton Control Stations Contents Page Features.............................. V7-T-5 Product Selection M22 Assembled Control Stations........ V7-T-6 Commercial Control
More informationType: DILEM 10(220V50HZ,240V60HZ) Article No.:
Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230
More informationHPS Universal BUCK-BOOST TRANSFORMERS
BUCK-BOOST TRANSFORMERS Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationSupplemental Motor Protection Devices Specifications
Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Page 809S/813S/814S/817 Dedicated Function Motor Protection Relays 2 Product
More informationFor additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:
Product Overview Providing users with powerful motor speed control in a compact, space saving design, the Allen-Bradley PowerFlex 4 and 40 AC drives are the smallest and most cost-effective members of
More informationPCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationFALL-OF-POTENTIAL GROUND RESISTANCE TESTER
FALL-OF-POTENTIAL GROUND RESISTANCE TESTER Models 3620, 3640 & 4610 Call toll free (800) 537-0351 or visit www.allspec.com Measures soil resistivity (4-Point) (Model 4610) Measures ground resistance (2-
More informationElectrical IP Red Seal Practice Exam
Electrical IP Red Seal Practice Exam PRACTICE EXAM-3 1. What size 2 pole breaker must you use on a 3HP, 115V single phase motor? A. 40A B. 50A C. 80A. D. 100A. 2. An electrical equipment approved for use
More informationECET 211 Electrical Machines and Controls
ECET 211 Electrical Machines and Controls 2016/4/27 Class Review and Wrapping Up Comprehensive Exam, Friday, 1:00-3:00 PM, May 6, 2016 Close books/allow 1-page (8 x 11 and ½) hand-written review note,
More informationMini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More information1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.
Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......
More informationType: DILEM 10 G(24VDC) Article No.:
Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220
More informationCharacteristics 5 TeSys k contactors and reversing contactors
90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to
More informationLiquid-Filled Transformers
Liquid-Filled Transformers Custom Transformers at Standard Prices NIAGARA TRANSFORMER CORP. Induction Furnace Transformer Cycloconverter Rectifier Duty Transformer Arc Furnace Transformer Full Range of
More informationDistribution/Substation Transformer
Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation
More informationSupplemental Motor Protection Devices Specifications
Technical Data Supplemental Motor Protection Devices Specifications Bulletin Numbers 809S, 813S, 814S, 817S, 1409, 1410 Topic Bulletin 809S/813S/814S/817S 2 Page Product Line Overview 2 Cat. No. Explanation
More informationAmpere Rating LAL MAL* NAL. 2-pole. 3-pole. Catalog No. Price $ QO300 QOU300 QO3000 QOU3000 QOU30001
MAG-GARD Motor Circuit Protector Class, 8, 6, 68 Instantaneous trip magnetic onl circuit breakers have a single adjustment which simultaneousl sets the magnetic trip level of each individual pole. MAG-GARD
More informationEnclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System
Technical Data TD008010EN Supersedes February 2016 Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System The information below is taken directly from the National Electrical CodeT (NEC)
More informationSECTION PANELBOARDS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section
More informationDISCONNECT SWITCHES. UL Listed CSA Certified
POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole
More informationDesign Specifications Operator Keypad Environmental and Operating Conditions
Series 15J Mini Inverters Big inverter features do come in small packages! Take a look at Baldor s Series 15J Inverter control. Designed to save cabinet space without giving up the features available on
More informationSemiconductor (AC) fuses
Main characteristics Recognized 650 to 300VAC / 63 to 2800A. Exceptionally low I 2 T, Watt losses. Non-magnetic construction, highly reliable low voltage. Indicator system. Conformity to UL, CSA investigated,
More informationDeploying Current Transformers in Applications Greater Than 200 A
Deploying Current Transformers in Applications Greater Than 200 A Andrew Schaeffler Step-down Current Transformers (CTs) are common, and useful, in large motor applications. They provide isolation between
More informationJ7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947
Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit
More informationPF/PFQ. High Amperage plug and receptacle. Main Advantages
High Amperage plug and receptacle Main Advantages u u u Durable in harsh environments Safety features provide maximum protection Easy plug insertion and removal Watch the PF video and other product videos
More informationINSTALLATION, OPERATION AND MAINTENANCE GUIDE
INSTALLATION, OPERATION AND MAINTENANCE GUIDE FOR INDOOR/OUTDOOR SINGLE PHASE ENCAPSULATED TRANSFORMERS Indoor/Outdoor Encapsulated Transformers The pictures used in this guide are only a representation
More informationDry Type Transformers Full Line Catalog. jeffersonelectric.com
Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production
More informationDescription Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module
DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)
More informationPCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.
More informationApplication Description
- N Mechanically Held February ontents Description Page Product Description...... - Application Description... - Features................ - Operation.............. - Instructional Leaflets..... - Standards
More informationPTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device
MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor
More informationSIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A
The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance
More informationAmpgard The name motor applications rely on
Medium-voltage motor control The name motor applications rely on Oil and gas Mining Water/wastewater Pulp and paper Utility A legacy of reliability for more than 4 decades 1950 1960 1970 1980* 1990 2000
More informationMotor Protection Circuit Breaker Series 8146/5-V27
www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationTransformer Questions & Answers
Transformer Questions & Answers. What is a transformer and how does it work? A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. It can be designed
More informationControl stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M
Characteristics Pendant control stations, for control circuits Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 XAC-B : standard version : NEMKO, CSA 300 V type 4 Approvals XAC-M : standard
More informationSECTION EQUIPMENT WIRING
PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 26 27 17 EQUIPMENT WIRING A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General Provisions,
More informationMicro and Mini Inverters
Micro and Mini Inverters Why Baldor? For over 85 years, Baldor has strived to provide customers with the best value and reliability in industrial electric motors. That dedication shows in customer preference
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More informationG6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.
Miniature High Capacity Relays with SPST-NO 0A and SPST-NO + SPST-NC A SPST-NO 0A and SPST-NO + SPST-NC A for power switching and output that satisfy the needs for space-saving. Small High-capacity Relays
More informationRatings for Switching AC Motors AC-2, AC-3, AC / /
Bulletin -C/-C Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Ie [A] Bulletin -C/-C Compact sizes from kw/ Hp ( A) AC and DC coil control Common accessories for all contactor
More informationVariable Frequency Drives
Table of Contents Variable Frequency Drives Product Product Code Resource Documents Page # Introduction F-3 SED2 154-042 F-5 with Conventional Bypass Option SED2 154-044 F-9 with Electronic (E) Bypass
More informationMiniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays
Miniature & Starters Series family of, Starters, and Overload & Industrial Relays Miniature, Starters, Overload Relays & Industrial Controls List Prices shown in this selection guide are for use in the
More informationType: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information
Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationSINPAC Switches: Brief Operating Description. Mounting Options
SINPAC Switches: Brief Operating Description For over 75 years, single-phase motors have utilized a mechanical centrifugal switch to switch the start circuit. Inherent characteristics of a mechanical device
More information