1 Liquid-Filled Transformers Custom Transformers at Standard Prices NIAGARA TRANSFORMER CORP.

2 Induction Furnace Transformer Cycloconverter Rectifier Duty Transformer Arc Furnace Transformer Full Range of Capability The strength of is our ability to understand customers requirements and to respond by providing transformers that meet these demanding specifications. Niagara Transformer produces liquid-filled transformers up to 20 MVA and 69 kv high voltage (350 kv BIL) either with oil filled, R-Temp, beta, alpha, ester, Envirotemp, or silicone fluids. Depending on the application, we offer conventional liquid-filled, sealed tank, conservator, or positive pressure nitrogen systems. Our transformers are built using copper, aluminum windings with circular, rectangular, or disk-style coil construction. Niagara provides transformers with manual and motorized de-energized tap changers and with load tap-changing equipment. We can also provide transformers with radiators, forced oil air, forced oil water, or oil natural water-cooled heat exchangers. Applications Process/high current rectification Traction duty Motor drive duty Primary unit substations with integrated primary and secondary switchgear Arc or induction furnace Test Retrofit Types of Transformers Rectifier transformers Unit substation transformers On-load tap-changing transformers Multi-tapped transformers Auto transformers Scott-connected transformers Pad-mount transformers Sealed liquid-filled transformers Design Styles Transformers can be designed to accommodate the following: Variable frequency motor drive Compartmentalized pad-mount Autotransformer Motor starting Corrosive/hazardous environments High ambient temperature/elevation Indoor/outdoor Dimensional restrictions

3 Unit Substation Power Transformer Forced Oil Cooled Power Transformer with Primary Switch Regulating Auto-Transformer with On-Load Tap Changer Built to Your Requirements By providing you with the exact configuration your transformer requires, Niagara Transformer minimizes the time and cost of field installation. There are no standard models at Niagara Transformer. Our design approach ensures that you receive exactly what you need at a competitive price. We can provide transformers with these specialized options: Coordinated HV and LV termination location Coordinated HV and LV elevation Special dimensions Special arrangement Nonstandard kva Nonstandard voltages Nonstandard BIL Nonstandard sound levels Special impedance (low or high) Special termination arrangements Low operating temperature rises Special footprints Retrofit accessory location Special paint color coordination 24-Hour Quotation Turnaround Niagara Transformer guarantees twenty-four hour turnaround on quotations including complete bill of material, technical data, and quotation sketches as required. If you need a faster response, then let us know. We will strive to meet your quotation requirements. Call toll-free Utility Substation Power Transformer

4 Unit Substation Transformer with Conservator Glass Furnace Transformer High-Current Process Rectifier Duty Transformer Superior Service & Value The hallmark of Niagara Transformer is our value-added approach to transformer design and manufacturing. Our goal is to provide custom-designed transformers that meet your specifications and requirements at standard transformer prices. Our products are noted for their long-term quality, and our service is responsive and customerfocused. If you have any questions about our products or company, please feel free to contact us to speak to a sales engineer. Quality Standards Niagara Transformer exceeds the stringent quality requirements of military, laboratory, OEM, utility, and industrial customers around the world. All Niagara Transformer products comply with the latest ANSI, IEEE, NEMA, IEC and CSA requirements. We can also offer special certifications from UL, CSA, and professional engineer seismic approval, as well as conform to international standards and verifying authorities such as Det Norske Veritas and the American Bureau of Shipping. On-Time Delivery We understand that our customers work on rigid schedules. When Niagara Transformer confirms a delivery, it is guaranteed to be on site when you need it. Unrivaled Experience has manufactured transformers for more than 60 years. Our engineering and manufacturing departments are comprised of professionals averaging more than 20 years of experience and include individuals recruited from organizations throughout the industry. Niagara s transformers are operating not only throughout the United States, but also in sixty-five other countries around the globe. Our company joined NEMA in 1942 and continues to be an international leader in standards development through IEEE, ANSI and IEC. Contact us for standard and custom features, accessories, ratings, or more information about our complete range of liquid-filled transformers.

5 General Specifications Coils All coils are designed based on the customer s specific application. The kva, voltage rating, and the application dictate the use of either circular or rectangular forms with windings as follows: Continuous Disk - for medium to high-voltage applications where impulse strength is important. Barrel - for medium-voltage and medium-current applications. Helical - for high-current applications offering high short-circuit strength and low winding eddy current losses. Sheet - for low-voltage, high-current applications and the elimination of axial forces on winding short circuits. Coils can be furnished with temperature rise ratings of 55 C above ambient. Enhanced rating of units is available for 65 C rise units. Cores Cores are made from high-grade, non-aging, grain-oriented, cold-rolled silicone steel. They are laminated for high-magnetic permeability and low hysteresis and eddy current losses. Niagara Transformer offers computer-generated cores designed for the customer s specific application. Wound cores for low-power and stacked cores for high-power applications are offered. Stacked cores can be rectangular or cruciform (stepped). Either can be butt-cut, mitered, or step-lap mitered. Specialized cores, such as 4-leg, 5-leg, and gapped also can be supplied. Insulating Fluids Niagara Transformer can supply every cooling fluid currently available. Mineral oil or Envirotemp typically are used outdoors. R-Temp, beta, alpha, ester, and silicone fluids are offered when higher fire point liquids are needed. Tank Design Niagara liquid-filled tanks are welded, oil-tight steel construction with structural bases designed to permit skidding or rolling in either centerline direction. Sealed tanks are designed to withstand, without permanent deformation, pressure greater than 25% of the maximum operating pressure. Large tank designs are suitable for full vacuum processing. Niagara Transformer can accommodate any required orientation of terminals - from simple cable terminals to inline substation configuration, to custom terminal locations. Types of oil preservation systems include: Sealed Tank Construction - where the transformer is sealed airtight and a gas space of nitrogen above the oil serves as a pressure buffer. Inert Gas System - where the breathing of inert gas is controlled to maintain a positive pressure of nitrogen within the transformer tank. Conservator Style Design - where a vented reservoir tank allows for thermal expansion and contraction of the transformer liquid. Suitable for forced oil cooling designs. Finishes Niagara Transformer s standard paint finish is ANSI #61, Light Gray. We can furnish any ANSI paint color specified, or match a paint color if a paint chip is supplied. Special finishes can be supplied on request for: Chemical and/or corrosive environments High-humidity locations Offshore and coastal, salt-laden environments Niagara Transformer can provide terminal locations in any ANSI segment number requested, including any of the following individually or in any combination: Full height terminal chambers Partial height terminal chambers Wall-mounted throats Wall-mounted flanges Cover-mounted Cooling Cooling is performed by panel-type radiators that provide additional radiating surfaces for self-cooled transformers. Additional cooling can be added using singlestage, forced-air cooling to increase capacity within guaranteed temperature limits for: Continuous operation Periods of overloading Seasonal changes of loading This extra cooling is provided by motor-driven fans mounted on the transformer base.

6 Mission Statement The mission of Niagara Transformer Corporation is to be a respected supplier of custom-designed electrical equipment and to support these products with responsive technical and customer service. Our company is recognized for its engineering and manufacturing flexibility and experience, product quality, industry reputation, and long-term dependability. Our customers are around the world as well as around the corner. In addition to supplying transformers throughout the United States and its territories, we have recently provided transformers to more than 65 countries around the world. NIAGARA TRANSFORMER CORP. P.O. Box Dale Road Buffalo, New York Phone: Toll-Free: Fax: mail@niagaratransformer.com Website:

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial

More information

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide MGM Transformer Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide MGM Transformer Company 5701 Smithway Street Commerce, CA 90040 www.mgmtransformer.com Phone: 323.726.0888

More information

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3 CONTENTS COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3 CONSTRUCTION... 4 ~ 5 A. CORE AND FRAME... 4 B. COIL... 5 C. TEMPERATURE INDICATOR... 5 CHARACTERISTICS... 6 MANUFACTURING FACILITIES...

More information

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs VIRGINIA TRANSFORMER CORP Individual solutions from a global perspective Drive & Rectifier Transformersrs Oil Drilling Paper Mill Virginia Transformer Commitment to our Customers Industry s Shortest Production

More information

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators Virginia Transformer is a leader in custom power transformers engineered precisely for your application and optimized

More information

Power Transformers Basics

Power Transformers Basics Power Transformers Basics Transformer Basic Objective Introduce Basic Transformer Theory as it Relates to Diagnostics Provide a Better Understanding of the Diagnostic Test Environment Identify Important

More information

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems Arild Furnes,ATPA OGP/Petrobras workshop, 22.09.09 Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems September 24, 2009 Slide 1 Transformers for Ships and Offshore -

More information

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers save energy, it is precious Mfg. of all types of Distribution / Power & Furnace Transformers SYNERGY transformers SAFETY AND EFFICIENCY, COMBINED WITH LONG-TERM RELIABILITY, ARE THE HALLMARKS OF WORLD-RENOWNED

More information

Mechanical Design. Brian Brinson Mechanical Design Manager.

Mechanical Design. Brian Brinson Mechanical Design Manager. Mechanical Design Brian Brinson Mechanical Design Manager brian.brinson@spx.com September 26, 2018 Agenda 1. Design Process 2. Pre-Approval Drawings Bid Drawings Preliminary Drawings 3. Approval Package

More information

Description. Features and Benefits

Description. Features and Benefits KA-108 The General Electric Type KA-108 Bushing Potential Device is a reliable, safe, economical voltage transforming device for the operation of instruments and relays from high-voltage circuits, 115

More information

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) 0.415/33kV DESIGN AND CONSTRUCTION General 1. The transformer shall be three phase, oil immersed type, air cooled, core type, outdoor

More information

Basic Principles and Operation of Transformer

Basic Principles and Operation of Transformer Basic Principles and Operation of Transformer CONSTRUCTIONAL ASPECTS Cores In order to enhance core s magnetic properties, it is constructed from an iron and silicon mixture (alloy). The magnetic core

More information

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers KNOW MORE ABOUT THE TRANSFORMERS Glossary Transformers Ambient temperature The existing temperature of the atmosphere surrounding a transformer installation. Ampere The practical unit of electric current.

More information

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015 PES & IAS NY Chapter And NY LMAG June 23 rd, 2015 High Temperature Insulation Systems and their use in Mobile Transformers Myron B. Bell, PE mbell@deltastar.com Delta Star, Inc. June 23 rd 2015 Introduction

More information

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS SECTION 16461C - DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.1 This section includes design and performance requirements for dry-type transformers rated for use on secondary distribution systems rated 600

More information

POWER TRANSFORMERS CATALOGUE

POWER TRANSFORMERS CATALOGUE COMPANY INFORMATION ARTRANS S.A. started off as a small factory in April 2, 1982 located in Mendoza, Argentina. Now, three decades later it is a globally recognized manufacturer of distribution, transmission,

More information

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with

More information

Power transformers for Network, Rectifiers, Furnace

Power transformers for Network, Rectifiers, Furnace E N G L I S H OTN, OTR, OTF Transformers Power transformers for Network, Rectifiers, Furnace TTR TTO OTN, OTR, OTF reactors TTH OTN, OTR, OTF Transformers Technology Design Our designers experience combined

More information

Electrical Design Process

Electrical Design Process Electrical Design Process Jason Varnell Lead Design Engineer Jason.Varnell@spx.com SPX Transformer Solutions, Inc. September 26, 2018 Agenda 1. Bid Design Process Parameters Affecting Bid Design 2. Final

More information

TMC Transformers TMC

TMC Transformers TMC TMC Product & Technology Presentation Cast Resin Transformer (CRT) History Cast resin transformers first appeared in Germany during the 1960s. This new style of dry type transformer was developed with

More information

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications Minnesota Power Systems Conference November 3 5, 2009 Earl Brown Heritage Center University of

More information

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI GENERAL: The scope of this document is to provide instruction for the installation and testing of Medium Voltage, 3 Phase, Pad Mounted Transformers installed at the University of Missouri. Preferred transformers

More information

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS Acme offers a large selection of Dry-Type Distribution Transformers. Ranging from 600 Volt and below, in both Single and Three Phase, you re sure to find

More information

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013) S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013) 1.0 GENERAL 1.1 This specification covers the electrical and mechanical

More information

Powering Your Business

Powering Your Business Powering Your Business THAI PATANAKIT TRANSFORMER www.thaipatanakit.co.th Company Background THAIPATANAKIT TRANSFORMER Co; Ltd. was established in 1984 under the name of SAHAPATANAKIT TRANSFORMER LIMITED

More information

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS n Bureau of Indian Standards (BIS) is the NATIONAL STANDARD BODY. Established

More information

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 4.0 Sectionalizer Construction... 4 5.0 Mechanism... 6 6.0 Solid Dielectric

More information

(

( (www.xatianhong.com) Introduction to XATH Xi'an Tianhong Electric Co., Ltd. (XATH) is a solely state-owned enterprise, set up by China Shipbuilding Industry Corporation (CSIC). It is one of the largest

More information

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

Efacec work every day to anticipate solutions for a sustainable world in the new energy era. Transformers Efacec is the largest industrial portuguese company of the electric and electromechanical sector developing high technology products, solutions and systems used every day by millions of people

More information

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R 5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R Part #: MT-ISX-FP-1P-115V-5KVA-230V-N3R Page: 1 The MT-ISX-FP-1P-115V-5KVA-230V-N3R 115V 1 Phase Energy

More information

Introduction. Centrado leading-edge transformer. Introduction

Introduction. Centrado leading-edge transformer. Introduction Introduction Centrado leading-edge transformer products are designed to optimize safety and produced to deliver a great electrical power experience and solution - for factory, infrastructure, home industry,

More information

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R 225 kva Autotransformer 240V Delta Primary Voltage 220V Delta Secondary Voltage NEMA 3R Part #: MTATX3P240D225KVA220DN3R Page: 1 The MTATX3P240D225KVA220DN3R 240D 3 Phase Energy Efficient Autotransformer

More information

OIL-IMMERSED ARC-SUPPRESSION COILS

OIL-IMMERSED ARC-SUPPRESSION COILS ISO 9001:2000 99-320 Żychlin, ul. Narutowicza 70 ISO 14001:2004 PN-N-18001:2004 www.ftz.pl Secretary s Office Tel.: +48 24 285 46 05, Fax: +48 24 285 46 31 zarzad@ftz.pl Sales and Marketing Department

More information

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor 500 kva Dry-type Isolation Transformer - 13200V-Delta to 208Y/120V 3PH - NEMA 1/Indoor Part #: MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Page: 1 The MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Dry-type Isolation

More information

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1 GENERAL: The scope of this document is to provide instruction for the installation and testing of Medium Voltage, 3 Phase, Pad Mounted Transformers installed at the University of Missouri. Preferred transformers

More information

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R 75 kva Isolation Transformer 4160V Delta Primary Voltage 480Y/277 Secondary Voltage NEMA 3R Part #: MTISX3P4160D75KVA480Y.277N3R Page: 1 The MTISX3P4160D75KVA480Y.277N3R 4160D 3 Phase Energy Efficient

More information

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO PART - A : SPECIFIC REQUIREMENTS THIS DATA SHEET IS APPLICABLE FOR IN BOILER A CLIMATIC CONDITIONS PACKAGE 1 DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.71 MTRS. 3 RELATIVE HUMIDITY 74 %

More information

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads. -156 Purpose & Industrial Control Purpose (1000 kva and Below) mounted dry-type transformers of the two-winding type, self-cooled, with ratings and voltages as indicated on the drawings. shall be manufactured

More information

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch. Training Title POWER TRANSFORMERS Training Duration 5 days Training Venue and Dates Power transformers 5 20-24 May $3,300 Abu Dhabi In any of the 5 star hotel. The exact venue will be informed soon. Training

More information

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz 7.5 kva Isolation Transformer 460V Primary 230V Secondary NEMA 3R Single Phase 50/60 Hz Part #: MTISX1P460V7.5KVA230VN3R50.60HZ Page: 1 The MTISX1P460V7.5KVA230VN3R50.60HZ 460V 1 Phase Energy Efficient

More information

NSP/ 007 / 006 Guidance on Substation Design: Transformer Transport, Delivery and Installation

NSP/ 007 / 006 Guidance on Substation Design: Transformer Transport, Delivery and Installation Version:- 1.0 of Issue:- March 2016 Page 1 of 7 NSP/ 007 / 006 Guidance on Substation Design: Transformer Transport, Delivery and Installation 1. Purpose The purpose of this document is to provide guidance

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-33 73 00.00 40 (November 2014) ----------------------------------- Preparing Activity: NASA Superseding UFGS-33 73 00.00 40 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UFGS (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-33 73 00.00 40 (November 2008) ----------------------------------- Preparing Activity: NASA Superseding UFGS-33 73 00.00 40 (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations 1.2 Description.1 UBC requirements for Substation Transformers. 2.0 MATERIAL AND DESIGN REQUIREMENTS

More information

nical catalogue Tech

nical catalogue Tech Technical catalogue About Etra 33 has been acting as transformer manufacturer over more than 75 years. Specializing in the manufacturing of power transformers rating up to 500 MVA and 420 kv the company

More information

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R 75 kva Isolation Transformer 480V Delta Primary 208V Delta Secondary NEMA 3R Part #: MTDOE163P480D75KVA208DN3R Page: 1 The MTDOE163P480D75KVA208DN3R 480D 3 Phase Energy Efficient Isolation Transformer

More information

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD. Our Ref : 2/2018- Date : Messrs: Dear Sir, Tender 2/2018 Main Transformers You are kindly requested to quote for the supply and delivery DDP to our stores the transformers detailed in the attached schedules

More information

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider Shunt Reactors Global Top Energy, Machinery & Plant Solution Provider Our Business Brief introduction of Hyosung Power & Industrial Systems PG While Hyosung is an established name for world-class electrical

More information

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient

More information

Hands-On Transformer Testing and Maintenance

Hands-On Transformer Testing and Maintenance Hands-On Course Description This Hands-On course will teach you how to prioritize your transformer maintenance strategy, stretch your maintenance budget and at the same time maximize the life and condition

More information

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R 10 kva Transformer 480V Primary Voltage 208V Secondary Voltage Single Phase NEMA 3R Part #: MTATX1P480V10KVA208VN3R Page: 1 The MTATX1P480V10KVA208VN3R 480V 1 Phase Energy Efficient Encapsulated Transformer

More information

HPS Universal BUCK-BOOST TRANSFORMERS

HPS Universal BUCK-BOOST TRANSFORMERS BUCK-BOOST TRANSFORMERS Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

Tougher than any challenge. Transformers for highcurrent. industrial applications. siemens.com/transformers

Tougher than any challenge. Transformers for highcurrent. industrial applications. siemens.com/transformers Tougher than any challenge Transformers for highcurrent and large drive industrial applications siemens.com/transformers Powering industry Water-cooled LV-side high-current U-tube bushings Metallurgical

More information

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase 80 kva Isolation Transformer 480V AC Primary 20V AC Secondary NEMA 3R Single Phase Part #: MTDOE161P480V80KVA20VN3R The MTDOE161P480V80KVA20VN3R 480V AC 1 Phase Energy Efficient Isolation Transformer from

More information

VARIABLE FREQUENCY RESONANT TEST SYSTEM

VARIABLE FREQUENCY RESONANT TEST SYSTEM VARIABLE FREQUENCY RESONANT TEST SYSTEM 400kV,1200kVA Tank Type Reactor for Outdoor Cable Test Field 650kV, 5850kVA, Cylinder Type Reactors for Onsite Testing of GIS and Cable PHENIX Variable Frequency

More information

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R 500 kva Isolation Transformer 480V Delta Primary 400Y/231 Wye Secondary NEMA 3R Part #: MTDOE163P480D500KVA400Y.231N3R Page: 1 The MTDOE163P480D500KVA400Y.231N3R 480 V Delta 3 Phase Energy Efficient Isolation

More information

SECTION TRANSFORMERS

SECTION TRANSFORMERS SECTION 16460 - TRANSFORMERS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Section

More information

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description General-Purpose Encapsulated.4 Type EP 3 5 Contents Description General-Purpose Encapsulated Catalog Selection................ Product Selection....................... Single-Phase..........................

More information

CAST RESIN DRY TRANSFORMER

CAST RESIN DRY TRANSFORMER CAST RESIN DRY TRANSFORMER Majority owned subsidiary company of ELETTROMECCANICA COLOMBO s.a.s., Italy Elettromeccanica India Elettromeccanica India Pvt Ltd (EIPL) is a joint-venture company with Elettromeccanica,

More information

T S 15KVA 1PH 240/480 Transformer

T S 15KVA 1PH 240/480 Transformer 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T2535173S 15KVA 1PH 240/480 Transformer Acme Electric Catalog Number Manufacturer Description Weight per unit Product

More information

Substation transformers

Substation transformers Substation transformers Triplex Indoor Power Centers Functional specification guide Functional specification for Triplex Indoor Power Centers (IPC) 750 2500 kva 1.0 Scope 1.1. This specification covers

More information

Ritz Instrument Transformers GmbH. Welcome

Ritz Instrument Transformers GmbH. Welcome Ritz Instrument Transformers GmbH Welcome About Ritz together with over 200 years of experience in instrument transformer production since 1945 since 1945 since 1945 since 1904 RITZ Group - Organization

More information

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS Management has tentatively approved your request subject to the following conditions: 1. All distribution materials/equipment must be purchased

More information

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE SUBSTATION TRANSFORMERS DRY-TYPE PART 1 GENERAL 1.01 1.02 1.03 1.04 SCOPE The Contractor shall furnish and install the primary and/or secondary substation transformers as specified herein and as shown

More information

Distribution/Substation Transformer

Distribution/Substation Transformer Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation

More information

TRANSFORMER TECHNOLOGY GPT

TRANSFORMER TECHNOLOGY GPT Core-Form TRANSFORMER TECHNOLOGY GlobalPT Corporation performs research and engineering developments and co-ordination of works of technical partners in the field of technological progress and commercial

More information

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,

More information

TRANSFORMER COM PANY. Dry Type Substation Transformers

TRANSFORMER COM PANY. Dry Type Substation Transformers TRANSFORMER COM PANY Dry Type Substation Transformers Special Design MGM Transformer Company manufactures transformers in six major categories: Special Design Dry Type Transformers: 9 kva to 10,000 kva

More information

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V This specification is property of SEC and subject to change or modification without

More information

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable: Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.

More information

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R 15 kva Isolation Transformer Single Phase 208V Primary 120/240V Secondary NEMA 3R Part #: MT20815KVA240.120 Page: 1 The MT20815KVA240.120 208V 1 Phase Energy Efficient Isolation Transformer from Larson

More information

Transformers TRANS FORM ERS

Transformers TRANS FORM ERS Transformers TRANS FORM ERS Meiden Transformers are standard design, standard quality. Our Factories on world-wide supply chain Since its founding in 1897 Meidensha Corporation has not only built up a

More information

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER Approval Amendment Record Approval Date Version Description 03/05/2017 1 Initial issue PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 1 of 13 Table of Contents 1. Purpose...

More information

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R 1.5 kva Single Phase Transformer 120V Primary Voltage 277V Secondary Voltage NEMA 3R Part #: MT120V1.5KVA277V Page: 1 The MT120V1.5KVA277V 120V 1 Phase Energy Efficient Transformer from Larson Electronics

More information

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Dry Type Transformers Full Line Catalog. jeffersonelectric.com Dry Type Transformers Full Line Catalog jeffersonelectric.com The Transformer Authority PIONEER TRANSFORMERS: Why us? Scale We produce over 100,000 transformers every year. With this high level of production

More information

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A Group F : No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS Table : A No. Description 1. Make & Manufacturer 2. Place of Manufacturer 3. Voltage Ratio 4. Rating

More information

Problems connected with Commissioning of Power Transformers

Problems connected with Commissioning of Power Transformers Problems connected with Commissioning of Power Transformers ABSTRACT P Ramachandran ABB India Ltd, Vadodara, India While commissioning large Power Transformers, certain abnormal phenomena were noticed.

More information

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) THREE-PHASE SUBSURFACE UNDERGROUND COMMERCIAL DISTRIBUTION (UCD) TRANSFORMER NOTE: This "Guide" summarizes the opinions, recommendations, and practices

More information

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- 0005/ DMRC-E-TR-TRANSF-05 SPECIFICATIONS FOR THREE PHASE 33 kv/415 V AUXILIARY Issued on: Date

More information

Transformer Factory Testing

Transformer Factory Testing Transformer Factory Testing John J. Foschia Test Engineer John.Foschia@spx.com September 2018 Reasons for Testing Compliance with user specifications Assessment of quality and reliability Verification

More information

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER. Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the

More information

2.1. Product Description

2.1. Product Description .1 NEMA TP-1 Energy-Efficient Type DT-3 Contents Description NEMA TP-1 Energy-Efficient Features, Benefits and Functions........... Standards and Certifications............... Catalog Selection................

More information

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER Engineering Specification TECHNICAL SPECIFICATION FOR AN ESSENTIAL Version: 3 Issued: 14 October 2016 Owner: Chief Engineer Approved By: Andrew Russack Head of Engineering - Electrical PRINTOUT MAY NOT

More information

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting TRANSFORMER OPERATIONAL Principles, Selection & Troubleshooting H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E www.ictd.ae ictd@ictd.ae Course Introduction: Power and distribution transformers

More information

Distribution Transformers

Distribution Transformers Distribution Transformers Single-Phase Pad-mounted Functional Specification Guide Functional Specification for Single-Phase Pad-Mounted Type Distribution Transformers 5 167 kva 1.0 Scope 1.1 This specification

More information

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

EE059: Transformer Operation, Maintenance, Diagnosis & Testing EE059: Transformer Operation, Maintenance, Diagnosis & Testing EE059 Rev.001 CMCT COURSE OUTLINE Page 1 of 5 Training Description: Power and distribution transformers are essential devices in electricity

More information

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K UNIT II TRANSFORMERS PART A 1. Define a transformer? A transformer is a static device which changes the alternating voltage from one level to another. 2. What is the turns ratio and transformer ratio of

More information

Transformers Contents Page

Transformers Contents Page Transformers Contents Page Introduction... / Product Range... / Electrical Design... / Transformer Loss Evaluation... / Mechanical Design... / Connection Systems... / Accessories and Protective Devices...

More information

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016) Typical Specification 1.2kV Class Energy Efficient Dry-Type Distribution Transformers Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016) Canada 595 Southgate Drive Guelph, Ontario N1G

More information

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS This specification is property of SEC and Subject to change or modification without any notice Table of Contents Clause Page 1.0 SCOPE

More information

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers .5 Transformers Distribution Transformers Three-Phase Type DT-3E Totally Enclosed Non-Ventilated Totally Enclosed Non-Ventilated Transformers Product Description Note: The following pages provide listings

More information

Substation Preventive Maintenance

Substation Preventive Maintenance Substation Preventive Maintenance PROVINCIAL ELECTRICITY AUTHORITY 1 Presentation Contents 1) A kind of substation 2) Electrical equipment details of AIS substation 3) Electrical equipment details of GIS

More information

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL PART 1: GENERAL 1. SCOPE This specification covers the design, engineering, manufacture, testing, supply, delivery, offloading and performance requirements of 11/0.433kV distribution transformers for outdoor

More information

Subject: Drive isolation transformers. VFD definition: History the short version. February 2012

Subject: Drive isolation transformers. VFD definition: History the short version. February 2012 February 2012 Subject: Drive isolation transformers This paper is designed to provide BASIC information on the application of transformers designed to manage secondary loads comprised largely of alternating

More information

Single & Three Phase Transformers SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank

Single & Three Phase Transformers SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank Single & Three Phase Transformers Learner Workbook Version 1 Training and Education Support Industry Skills Unit Meadowbank Product Code: 5634 Table of Contents Introduction... 5 Section 1. Transformer

More information

Regional Technical Seminar

Regional Technical Seminar Regional Technical Seminar TRANSFORMER 101 Transformer 101 Dharam Vir Vice President of Engineering Dharam.Vir@spx.com Agenda 1.Review transformers: How they work (textbook vs reality) 2.How do we build

More information

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED Dial : (033)2677-5835 & 2667-8358 Tele Fax : (033)2667-8358 Manufacturer of Dry Type Transformers E-mail : unimag111@gmail.com Office & Factory : 26/5, Sarat Chatterjee Road, Howrah 711 104, West Bengal,

More information

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CP RC Resonance circuit for GIS testing A new approach to testing gas-insulated switchgear Testing gas-insulated switchgear

More information

Vacuum Interrupters for Medium Voltage

Vacuum Interrupters for Medium Voltage for Medium Voltage Reliable, Maintenance-Free and Environmentally Friendly Today, vacuum as an arc extinguishing medium provides the most cost-effective solution for medium-voltage circuit-breakers. Siemens

More information

Siemens Transformer Technology Seminar Insulation & Thermal Design

Siemens Transformer Technology Seminar Insulation & Thermal Design Customer Technical Meeting Pomona, CA May 24 25, 2016 Siemens Transformer Technology Seminar Insulation & Thermal Design Siemens AG Transformers siemens.com/answers Winding Selection Windings: Page 2 Winding

More information