1 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 3, JUNE Radiation Effects on the Performance of CMOS Photodiode Array Detectors and the Role of Gain-Offset Corrections Ho Kyung Kim, Min Kook Cho, Thorsten Achterkirchen, and Wonho Lee Abstract We report the observation of performance degradation in a detector consisting of a phosphor screen and a CMOS (complementary metal-oxide-semiconductor) photodiode array under the continuous irradiation of 45-kVp x-rays. The performance was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). From the measurement results, it has been observed that the increase of dark pixel signal and the related noise gradually reduces the dynamic range as the cumulative input exposure to the detector increases. Severe degradation in NPS was observed, which gives rise to reduction in DQE as the cumulative input exposure increases. With carefully updated offset and gain correction, however, we can overcome the detrimental effects of increased dark current on NPS and DQE. Index Terms CMOS detector, CMOS devices, detective quantum efficiency, digital radiography, flat-field correction, image evaluation, image sensors, noise-power spectrum, radiation effects, X-ray imaging. I. INTRODUCTION VOLUMETRIC computed tomography (CT) based on flatpanel detectors has recently become popular in diverse application fields such as image-guided radiotherapy [1], angiography [2] and small-animal imaging [3]. In every moment of any given imaging task and thus over the lifetime of a detector, deposition of a certain amount of radiation dose in an electronic pixel element is inevitable. This radiation effect can give rise to a change in the pixel-element characteristics such as the leakage current of a photodiode and the threshold voltage of a thin-film transistor (TFT) [4], [5], which may consequently degrade the performance and image quality of the imaging detector. While a large amount of effort has been invested in evaluating the performance degradation of the pixel-element devices themselves due to the radiation damage, there has not been sufficient attention paid to the evaluation of performance degrada- Manuscript received June 27, 2008; revised November 25, Current version published June 10, This work was supported by the Korea Research Foundation Grant ("KRF D01339) and the Basic Research Program of the Korea Science & Engineering Foundation (R ) funded by the Korean Government. *H. K. Kim was the corresponding author for this article. *H. K. Kim and M. K. Cho are with the Mechanical Engineering Department, Pusan National University, Busan , Korea ( hokyung@pusan.ac.kr; mk2000@pusan.ac.kr).. T. Achterkirchen is with Rad-icon Imaging Corp., Santa Clara, CA USA ( achterkirchen@rad-icon.com). W. Lee is with the Radiological Science Department, Korea University, Seoul, Korea ( wonhol@korea.ac.kr). Digital Object Identifier /TNS tion of an imaging detector that is an important issue affecting the quality control and assurance of detectors over their lifetime. We have investigated the effects of radiation on the image quality of a CMOS (complementary metal-oxide-semiconductor) photodiode array detector coupled (via direct contact) to a phosphor screen. This CMOS detector is becoming popular in medical imaging applications because of its unique advantages, such as very low image lag and larger pixel fill factor compared to conventional flat-panel detectors based upon amorphous silicon TFT technology [6]. We have constructed an experimental setup to provide a large radiation dose to the CMOS detector, and measured dark signal and noise performance as a function of the radiation exposure. Based upon the measured dark signal and noise, we defined a parameter related to the dynamic range and investigated its degradation as a function of the cumulative input exposure. In addition, we measured the performance in terms of modulation-transfer function (MTF), noise-power spectrum (NPS) and detective quantum efficiency (DQE). We report the observation of radiation effects and discuss the role of offset and gain corrections on these metrics. II. MATERIALS AND METHODS A. Sample Detector Preparation We constructed a sample detector with a commercial phosphor screen (Min-R, Eastman Kodak, USA) and a CMOS photodiode array. The phosphor screen is mainly made up of terbium-doped gadolinium oxysulfide (Gd O S:Tb) and a polyurethane elastomer as the phosphor and binder, respectively. The thickness is 90 m and the density is 3.77 g/cm. The detailed physical configuration, parameters and specifications are described in [7]. The CMOS photodiode array has a format of pixels with a pitch of 48 m [8]. The photodiode array uses a source-follower configuration to read out the pixel voltage. The pixel consists of a photodiode to collect charge, a reset switch to apply a reverse-bias voltage to the photodiode, a row-select switch to select that pixel for read out, and a source-follower to convert the charge to voltage onto a column bus. This active pixel configuration, unlike the passive pixel design used in amorphous silicon TFT detectors, does not require an amplifier on each column because it is sufficient to sample the voltage on the column bus. In most cases, the gain of the pixel source-follower, i.e., the transfer gain from the photodiode voltage to the voltage on the column bus, is slightly less than unity. There are several source-follower stages in the signal processing chain /$ IEEE

2 1180 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 3, JUNE 2009 The total conversion gain from the pixel to sensor output is 0.5 V/, and the pixel full-well capacity is approximately. The photodiodes in the CMOS photodiode array are always integrating, which means that it is always collecting charge. The readout mechanism is similar to the correlated double sampling (CDA) technique, which is widely used in CCDs (charge-coupled devices) to reduce switching transients and to eliminate reset noise. The signal values from an entire row of photodiodes are sampled onto a set of capacitors, then the photodiodes are reset, and then the reset values from the same pixels are sampled onto a second set of capacitors. The readout then proceeds by reading out the stored voltages from both sets of capacitors. Voltage signals from the CMOS photodiode array are then digitized to 12-bit resolution by an analog-to-digital converter (ADC). During the measurements, the frame time of the CMOS detector was fixed at 540 ms, although it is variable and the maximum frame rate is 4.5 frames per second (fps). B. Experimental and Image Data Analysis A sealed x-ray source (Series 5000 Apogee, Oxford Instruments, USA) with a fixed tungsten anode and a 125- m-thick beryllium exit window was used to irradiate the detector. In general, the radiation effect on a device is evaluated in terms of the total ionizing dose (or total dose), which is the accumulated energy per unit mass of the device [9]. It is, however, difficult to directly measure the actual energy absorbed in the device. Instead, we measured the exposure rate in Roentgens (R) at the detector entrance surface by using a calibrated ion chamber (Victoreen , Inovision, USA). For the sample detector, the irradiation was performed using a 45-kVp x-ray spectrum tailored by a 1-mm-thick aluminum filter, which gives an exposure rate of 13 R/min measured at a distance of 200 mm from the source. The following measurements are reported as a function of cumulative input exposure at the entrance surface of the CMOS detector; in other words, the measured exposure rate multiplied by the elapsed irradiation time. Eight images were obtained to evaluate the dark signal and noise with respect to the cumulative input exposure. Each image was divided into eight non-overlapping sub-image sections, each consisting of pixels. Thus a total of 64 region-of-interests (ROIs) were used for the evaluation. The increased dark signal in the detector can be corrected using the offset correction algorithm that is part of the typical digital x-ray imaging procedure. However, radiation-induced dark signal can cause a decrease in capacity of signal charge or bit-depth. The reduction of bit-depth is the loss of range available to image different anatomies with different attenuation values in medical imaging. Therefore, the reduction of signal capacity is crucial to the long-term use of a detector. The conventional definition of dynamic range is the ratio of the maximum signal divided by the noise of the signal. In order to investigate the reduction of signal capacity, instead we have defined a modified dynamic range as a function of the cumulative input exposure (1) where and are the maximum signal and the dark signal at cumulative input exposure, respectively. is the standard deviation of the dark signal at cumulative input exposure. The upper bar denotes the mean value. It should be noted that ADU in this study. The performance of the CMOS detector has been measured in terms of MTF, NPS, and DQE. A detailed description of measurement procedures can be found in the [6], [10]. Briefly, the presampling MTF was measured using a slanted-slit method to avoid aliasing [11] and the NPS was determined by two-dimensional (2D) Fourier analysis of white images [12]. The DQE was assessed from the measured MTF, NPS, and the estimated photon fluence. The fluence was calculated using the experimentally measured exposure and half-value layer (HVL), and a computational program for x-ray spectral analysis [13]. In this study, the NPS is calculated by where the vector form designates a spatial-frequency conjugate in Fourier domain to in space domain and indicates a 2D fast Fourier transformation of an image. is the mean value of the data within a subarray of a white image being investigated. On the contrary, a normalized NPS (NNPS), which is typically used for the evaluation of DQE because it does not require the additional measurement of the detector gain, is calculated by In order to investigate the effect of different gain-offset correction procedures on the detector performance, three different correction procedures were applied when obtaining an NPS or NNPS. In the first method, for an image investigated at a given cumulative input exposure, the image is corrected with initial dark and white images obtained just before the continuous x-ray irradiation such that The symbol denotes an ensemble average of images and denotes the process of taking a subarray image from the corrected white image. denotes the mean value of the offset corrected image in a restricted area, usually a central region of the detector. In diagnostic radiology with conventional flat-panel digital radiography (DR) detectors, the concept of gain-offset correction is similar to this correction procedure. Averaged dark and white images are first obtained when the DR system is initialized and are subsequently used for the gain-offset correction procedure during the daily diagnostic imaging tasks. In the second method, the correction is carried out with initial dark images obtained just before the continuous irradiation and (2) (3) (4)

3 KIM et al.: RADIATION EFFECTS ON THE PERFORMANCE OF CMOS PHOTODIODE ARRAY DETECTORS 1181 Fig. 1. Signal and noise properties in the CMOS detector during irradiation. (a) Dark signal of the CMOS detector as a function of the cumulative input exposure. (b) Log-log plot of noise versus dark signal of the CMOS detector. Noise property of difference images, which contain only random noise, is also plotted. refreshed white images obtained at the corresponding cumulative exposure level In the third method, the offset and gain correction is carried out with refreshed dark and white images: (5) III. RESULTS Fig. 1(a) shows the measured dark signal of the CMOS detector as a function of the cumulative input exposure. It is noted that the dark signal is expressed in ADC units (ADU). As the cumulative input exposure increases, the dark signal also increases. In Fig. 1(b) a log-log plot of noise versus dark signal demonstrates a signal-dependent noise contribution to signal values. As shown in Fig. 1(b), the signal-noise dependency can be categorized into three regions for the dark signal levels; a signal-independent or constant region, a square root proportional region and a linear proportional region. The constant region reflects the read noise of the detector, which initially dominates all other noise sources. As the radiation-induced dark current begins to increase, the noise also increases with a square-root dependence, since the dark current generation is a thermal process and thus follows Poisson statistics. Finally, the increased dark current becomes pronounced enough to form a fixed-pattern background, where the standard deviation increases linearly with the signal. It should be noted that this background can be subtracted out by periodically renewing the offset calibration, but for this illustration the same offset correction was applied to images taken at all cumulative input exposure levels. (6) Fig. 2. Dynamic range with respect to the cumulative input exposure. The dynamic range defined in this study decreases as the cumulative input exposure is increased, due to a gradual reduction in signal charge capacity as well as a simultaneous rise in noise levels. Dynamic range estimated based on difference images is also plotted. Noise of the difference of two dark images obtained at the same cumulative input exposure as a function of the dark signal level is also plotted in Fig. 1(b). Subtraction of two images obtained under identical condition produces an image free from fixed-pattern noise (FPN). According to the noise plot obtained from the difference images, as shown in Fig. 1(b), most of the noise in the dark images induced by irradiation is FPN. It is noted that the noise for each difference image was corrected by dividing by because the two images have independent noise samples with equal standard deviation. The calculated dynamic range defined in this study is plotted in Fig. 2 based on the measured dark signal and noise. As expected, the dynamic range decreases as the cumulative input exposure increases because of the increase of noise and the enhanced dark current. The dynamic range drops by a factor of 100 over the course of the experiment. However, based on the difference images, i.e., by removing the FPN, the drop is a factor of about 10. The reduction in dynamic range during the use of detectors is significant for any clinical imaging application for the obvious reason of loss of range available for the expected range of x-ray intensities after attenuation by human anatomy. Fig. 3 plots the measured MTF of the detector with respect to the cumulative input exposure. As shown in Fig. 3, the MTF

4 1182 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 3, JUNE 2009 Fig. 3. Measured MTFs of the CMOS detector with respect to the cumulative input exposure. MTF, which describes the resolving power of an imaging system, is rarely affected by the cumulative input exposure. The exceptional degradation at a cumulative input exposure of about 3.6 kr is caused by that the slit image was very noisy. Fig. 5. Normalized NPSs of the CMOS detector with respect to the cumulative input exposure for three different gain-offset correction procedures. Fig. 4. Measured NPSs of the CMOS detector with respect to the cumulative input exposure. Three different gain-offset correction procedures with initial dark and white images (a), initial dark and refreshed white images (b), and refreshed dark and white images (c) are applied. The NPS measures the change in the noise amplitude as a function of spatial frequency and bridges the noise and spatial resolution in an image. performance was very slightly affected by the cumulative input exposure except at the very highest level of about 3.6 kr. However, since the slit images obtained for the MTF evaluation became more noisy as the cumulative input exposure increased, it was difficult to analyze whether the degradation is due to the irradiation or not. The measured NPS curves with respect to three different correction methods are plotted in Fig. 4. For sequential images obtained during continuous irradiation, gain-offset correction with the initial dark and white images obtained just before irradiation (or kr of the relative cumulative exposure) produces incremental noise-power densities in NPS as the cumulative exposure increases. This is due to the addition of increased dark current dependent on the amount of irradiation in white images. Since the fixed-pattern background in the dark and white images is getting dominant as the cumulative exposure increases, the improper gain-offset correction may yield a noticeable pattern in the NPS. As shown in Fig. 4(a), peaks at the low spatial-frequency region are observed. The FPN in this study is then characterized as long-range non-uniformities in an image. On the other hand, regardless of the use of initial or refreshed dark images, gain-offset corrections with refreshed white images obtained at the corresponding exposure produce the consistent NPS results as shown in Fig. 4(b) and (c). The importance of the use of proper dark images in the gainoffset correction procedure can be observed by investigating the normalized NPS curves. As shown in Fig. 5(b), normalized spectral densities in NNPSs based on the refreshed white but initial dark images decreases as the cumulative input exposure increases because increases as the cumulative input exposure increases. Therefore, only the gain-offset correction procedure with the refreshed dark and white images can produce the consistent NPS and NNPS results. From the measured MTF and NNPS, the resultant DQE of the detector with respect to the cumulative input exposure is shown in Fig. 6. In order to match the spatial frequencies between the MTF and NNPS, we fitted the MTF data with a Lorenzian function. The DQE at the highest level of dose of about 3.6 kr was excluded in the calculation because of the inconsistent MTF data. As shown in Fig. 6, DQE is mainly dependent on the NNPS. IV. DISCUSSION The measured dark signal depends on the photodiode, the transistors and the interconnectivity in a pixel [14]. Among them, the contribution of the photodiode dark current is highest. The main physical mechanism responsible for the increasing dark current in the photodiode is the buildup of positive charge in the silicon dioxide (SiO ) layer. When an x-ray photon is

5 KIM et al.: RADIATION EFFECTS ON THE PERFORMANCE OF CMOS PHOTODIODE ARRAY DETECTORS 1183 providing the electrons in the silicon substrates with enough energy to jump back into the SiO layer, for example by using thermal energy as the activation energy. As shown in Fig. 7, while room-temperature annealing did not work to restore the dark signal, we have had some success with annealing the damaged CMOS photodiode array by baking it in a vacuum oven at a temperature around 100 C for 58 hours, while taking precautions not to degrade the materials inside the array at higher temperatures. If we can apply higher temperatures, the deeper traps could be relieved. Fig. 6. DQEs of the CMOS detector with respect to the cumulative input exposure for three different gain-offset correction procedures when estimating NPSs. The DQE measures the fraction of incident fluence contributing to an image quality. V. CONCLUSION We have measured the radiation damage and its effect on the performance of a CMOS photodiode array in conjunction with a phosphor screen in terms of dark signal, noise, dynamic range, MTF, NPS and DQE. For the accumulation of the radiation exposure, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. Most noise in dark images induced by irradiation is a fixed-pattern background. Although the radiation-induced noise can affect the NPS or NNPS, and hence DQE, the proper gain-offset correction with carefully updated dark and white images can prevent this type of degradation. This study gives an initial motivation that the periodic monitoring of the performance degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors. Fig. 7. Effect of annealing on the restoration of signal capacity in the CMOS detector. The hatched area indicates an occasional forced heat-treatment in a vacuum oven at around 100 C for 58 hours. absorbed in the SiO layer, it can accelerate electrons out of the SiO and into the silicon substrate. Since the SiO is a dielectric, it cannot replace the missing electrons. Consequently, over time, a positive charge builds up in the SiO. This charge distribution gives rise to an electric field that modifies the band levels in the active devices. In other words, positive charges in the SiO cause electrons to accumulate underneath the surface, modifying the charge density in the depletion region and thereby increasing the leakage current across the - junction of the photodiode. The dark current becomes stronger with increasing absorbed dose. For radiation-induced dark signal, Bogaerts and Dierickx [14] simply modeled that the thermal generation predominantly follows from the creation of interface traps. From the measurements in this study, we found that the dark signal almost linearly increased up to a cumulative input exposure of kr, and that increase of the dark signal accelerated even further beyond kr. Radiation-induced interface traps in the SiO layer are in general positive ions. Some missing electrons can be restored by REFERENCES [1] D. A. Jaffray and J. H. Siewerdsen, Cone-beam computed tomography with a flat-panel imager: Initial performance characterization, Med. Phys., vol. 27, no. 6, pp , [2] R. Ning, B. Chen, R. Yu, D. Conover, X. Tang, and Y. Ning, Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation, IEEE Trans. Med. Imag., vol. 19, no. 9, pp , [3] S. C. Lee, H. K. Kim, I. K. Chun, M. H. Cho, S. Y. Lee, and M. H. Cho, A flat-panel detector based micro-ct system: Performance evaluation for small-animal imaging, Phys. Med. Biol., vol. 48, no. 24, pp , [4] J. M. Boudry and L. E. Antonuk, Radiation damage of amorphous silicon photodiode sensors, IEEE Trans. Nucl. Sci., vol. 41, no. 4, pp , [5] J. M. Boudry and L. E. Antonuk, Radiation damage of amorphous silicon, thin-film, field-effect transistors, Med. Phys., vol. 23, no. 5, pp , [6] H. K. Kim, S. C. Lee, M. H. Cho, S. Y. Lee, and G. Cho, Use of a flat-panel detector for microtomography: A feasibility study for smallanimal imaging, IEEE Trans. Nucl. Sci., vol. 52, no. 1, pp , [7] J.-M. Kim, H. K. Kim, M. H. Cheong, M. K. Cho, C.-S. Shon, and C. H. Lim, Investigation of scintillation screens for x-ray imaging, Key Eng. Mater., vol , pp , [8] T. Graeve and G. Weckler, High-resolution CMOS imaging detector, in Proc. SPIE, 2001, vol. 4320, pp [9] H. J. Barnaby, Total-ionizing-dose effects in modern CMOS technologies, IEEE Trans. Nucl. Sci., vol. 53, no. 6, pp , [10] M. K. Cho, H. K. Kim, T. Graeve, and J.-M. Kim, Characterization of CMOS pixel detectors for digital x-ray imaging, Key Eng. Mater., vol , pp , [11] H. Fujita, D. Y. Tsai, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, A simple method for determining the modulation transfer function in digital radiography, IEEE Trans. Med. Imag., vol. 11, no. 1, pp , [12] E. Samei and M. J. Flynn, An experimental comparison of detector performance for direct and indirect digital radiography systems, Med. Phys., vol. 30, no. 4, pp , [13] C.-S. Shon, H. K. Kim, M. K. Cho, M. H. Cheong, C. H. Lim, and J.-M. Kim, Computational toolset for x-ray spectral analysis, Key Eng. Mater., vol , pp , [14] J. Bogaerts and B. Dierickx, Total dose effects on CMOS active pixel sensors, in Proc. SPIE, 2000, vol. 3965, pp

An aging study of the signal and noise characteristics in large-area CMOS detectors

An aging study of the signal and noise characteristics in large-area CMOS detectors An aging study of the signal and noise characteristics in large-area CMOS detectors Jong Chul Han a, Seungman Yun a, Chang Hwy Lim a, Tae Gyun Youm a, Sung Kyn Heo b, Tae Woo Kim b, Ian Cunningham c, Ho

More information

Digital Detector Array Image Quality for Various GOS Scintillators

Digital Detector Array Image Quality for Various GOS Scintillators Digital Detector Array Image Quality for Various GOS Scintillators More info about this article: http://www.ndt.net/?id=22768 Brian S. White 1, Mark E. Shafer 2, William H. Russel 3, Eric Fallet 4, Jacques

More information

Development of a large-area CMOS-based detector for real-time x-ray imaging

Development of a large-area CMOS-based detector for real-time x-ray imaging Development of a large-area CMOS-based detector for real-time x-ray imaging Sung Kyn Heo a, Sung Kyu Park a, Sung Ha Hwang a, Dong Ak Im a, Jari Kosonen a, Tae Woo Kim a, Seungman Yun b, Ho Kyung Kim b*

More information

Amorphous Selenium Direct Radiography for Industrial Imaging

Amorphous Selenium Direct Radiography for Industrial Imaging DGZfP Proceedings BB 67-CD Paper 22 Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15-17, 1999, Berlin, Germany Amorphous Selenium Direct Radiography for Industrial

More information

MTF and NPS of single-shot dual-energy sandwich detectors

MTF and NPS of single-shot dual-energy sandwich detectors MTF and NPS of single-shot dual-energy sandwich detectors Junwoo Kim, a Dong Woon Kim, a Hanbean Youn, b,c Ho Kyung Kim a,c a School of Mechanical Engineering, Pusan National University, Busan 609-735,

More information

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC R. Bellazzini a,b, G. Spandre a*, A. Brez a, M. Minuti a, M. Pinchera a and P. Mozzo b a INFN Pisa

More information

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image Introduction Chapter 16 Diagnostic Radiology Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther In diagnostic radiology

More information

Development of Solid-State Detector for X-ray Computed Tomography

Development of Solid-State Detector for X-ray Computed Tomography Proceedings of the Korea Nuclear Society Autumn Meeting Seoul, Korea, October 2001 Development of Solid-State Detector for X-ray Computed Tomography S.W Kwak 1), H.K Kim 1), Y. S Kim 1), S.C Jeon 1), G.

More information

Performance Evaluation of a Flat-panel Detector-based Microtomography System for Small-animal Imaging

Performance Evaluation of a Flat-panel Detector-based Microtomography System for Small-animal Imaging Performance Evaluation of a Flat-panel Detector-based Microtomography System for Small-animal Imaging Ho Kyung Kim, Sang Chul Lee, In Kon Chun, Myung Hye Cho, Min Hyoung Cho, Member, IEEE, Soo Yeol Lee

More information

The Effect of Direct X-ray on CMOS APS imager for Industrial Application

The Effect of Direct X-ray on CMOS APS imager for Industrial Application The Effect of irect X-ray on CMOS APS imager for Industrial Application Kwang Hyun Kim a, b, Gyuseong Cho a a epartment of Nuclear Quantum Engineering, Korea Advanced Institute of Science and Technology,

More information

Photons and solid state detection

Photons and solid state detection Photons and solid state detection Photons represent discrete packets ( quanta ) of optical energy Energy is hc/! (h: Planck s constant, c: speed of light,! : wavelength) For solid state detection, photons

More information

Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flat-panel imager

Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flat-panel imager Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flat-panel imager Youcef El-Mohri, a) Kyung-Wook Jee, Larry E. Antonuk, Manat Maolinbay,

More information

3084 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 60, NO. 4, AUGUST 2013

3084 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 60, NO. 4, AUGUST 2013 3084 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 60, NO. 4, AUGUST 2013 Dummy Gate-Assisted n-mosfet Layout for a Radiation-Tolerant Integrated Circuit Min Su Lee and Hee Chul Lee Abstract A dummy gate-assisted

More information

Fundamentals of CMOS Image Sensors

Fundamentals of CMOS Image Sensors CHAPTER 2 Fundamentals of CMOS Image Sensors Mixed-Signal IC Design for Image Sensor 2-1 Outline Photoelectric Effect Photodetectors CMOS Image Sensor(CIS) Array Architecture CIS Peripherals Design Considerations

More information

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY 12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY Rajashekar

More information

10/26/2015. Study Harder

10/26/2015. Study Harder This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura Study Harder CR detection is inefficient, inferior to film screen

More information

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them? Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them? Definition and Validation of Exposure Indices Ingrid Reiser, PhD DABR Department of Radiology University of Chicago

More information

A ghost story: Spatio-temporal response characteristics of an indirect-detection flat-panel imager

A ghost story: Spatio-temporal response characteristics of an indirect-detection flat-panel imager A ghost story: Spatio-temporal response characteristics of an indirect-detection flat-panel imager J. H. Siewerdsen a) and D. A. Jaffray Department of Radiation Oncology, William Beaumont Hospital, Royal

More information

O 2. Image Quality Assessment of a CMOS/Gd 2. S:Pr,Ce,F X-ray Sensor. Journal of Physics: Conference Series PAPER OPEN ACCESS

O 2. Image Quality Assessment of a CMOS/Gd 2. S:Pr,Ce,F X-ray Sensor. Journal of Physics: Conference Series PAPER OPEN ACCESS Journal of Physics: Conference Series PAPER OPEN ACCESS Image Quality Assessment of a CMOS/Gd 2 O 2 S:Pr,Ce,F X-ray Sensor To cite this article: C M Michail et al 2015 J. Phys.: Conf. Ser. 637 012018 View

More information

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities Journal of Physics: Conference Series PAPER OPEN ACCESS Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities Recent citations - Resolution Properties of a

More information

Analysis of 1=f Noise in CMOS Preamplifier With CDS Circuit

Analysis of 1=f Noise in CMOS Preamplifier With CDS Circuit IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 49, NO. 4, AUGUST 2002 1819 Analysis of 1=f Noise in CMOS Preamplifier With CDS Circuit Tae-Hoon Lee, Gyuseong Cho, Hee Joon Kim, Seung Wook Lee, Wanno Lee, and

More information

Charged Coupled Device (CCD) S.Vidhya

Charged Coupled Device (CCD) S.Vidhya Charged Coupled Device (CCD) S.Vidhya 02.04.2016 Sensor Physical phenomenon Sensor Measurement Output A sensor is a device that measures a physical quantity and converts it into a signal which can be read

More information

10/3/2012. Study Harder

10/3/2012. Study Harder This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura Study Harder CR detection is inefficient, inferior to film screen

More information

Modeling detector performance in digital mammography using the linear cascaded systems approach

Modeling detector performance in digital mammography using the linear cascaded systems approach 51 Modeling detector performance in digital mammography using the linear cascaded systems approach V. Spyropoulou a,b, N. Kalivas a,b, A. Gaitanis a,b, C. Michail a,b, G. Panayiotakis b, I. Kandarakis

More information

Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications

Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications L. E. Antonuk, a) K.-W. Jee, Y. El-Mohri, M. Maolinbay, S. Nassif, X. Rong,

More information

Radiographic sensitivity improved by optimized high resolution X -ray detector design.

Radiographic sensitivity improved by optimized high resolution X -ray detector design. DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France Radiographic sensitivity improved by optimized high resolution X -ray detector

More information

High Performance Amorphous Silicon Image Sensor for X-ray Diagnostic Medical Imaging Applications

High Performance Amorphous Silicon Image Sensor for X-ray Diagnostic Medical Imaging Applications High Performance Amorphous Silicon Image Sensor for X-ray Diagnostic Medical Imaging Applications Richard L. Weisfield *, Mark Hartney, Roger Schneider, Koorosh Aflatooni, Rene Lujan dpix, LLC, Palo Alto,

More information

X-ray detectors in healthcare and their applications

X-ray detectors in healthcare and their applications X-ray detectors in healthcare and their applications Pixel 2012, Inawashiro September 4th, 2012 Martin Spahn, PhD Clinical applications of X-ray imaging Current X-ray detector technology (case study radiography

More information

Semiconductor Detector Systems

Semiconductor Detector Systems Semiconductor Detector Systems Helmuth Spieler Physics Division, Lawrence Berkeley National Laboratory OXFORD UNIVERSITY PRESS ix CONTENTS 1 Detector systems overview 1 1.1 Sensor 2 1.2 Preamplifier 3

More information

Estimation of signal transfer property for wireless digital detector in different measurement schemes

Estimation of signal transfer property for wireless digital detector in different measurement schemes Estimation of signal transfer property for wireless digital detector in different measurement schemes Anatoli Vladimirov, Kalle Kepler Training Centre of Medical Physics, University of Tartu, Estonia 11

More information

Computed tomography with single-shot dual-energy sandwich detectors

Computed tomography with single-shot dual-energy sandwich detectors Computed tomography with single-shot dual-energy sandwich detectors Seung Ho Kim, a Hanbean Youn, b,c Daecheon Kim, a Dong Woon Kim, a Hosang Jeon, b,c Ho Kyung Kim a,c a School of Mechanical Engineering,

More information

High-end CMOS Active Pixel Sensor for Hyperspectral Imaging

High-end CMOS Active Pixel Sensor for Hyperspectral Imaging R11 High-end CMOS Active Pixel Sensor for Hyperspectral Imaging J. Bogaerts (1), B. Dierickx (1), P. De Moor (2), D. Sabuncuoglu Tezcan (2), K. De Munck (2), C. Van Hoof (2) (1) Cypress FillFactory, Schaliënhoevedreef

More information

Development of Personal Dosimeter Using Electronic Dose Conversion Method

Development of Personal Dosimeter Using Electronic Dose Conversion Method Proceedings of the Korean Nuclear Spring Meeting Gyeong ju, Korea, May 2003 Development of Personal Dosimeter Using Electronic Dose Conversion Method Wanno Lee, Bong Jae Lee, and Chang Woo Lee Korea Atomic

More information

Characteristics of a new cone beam computed tomography

Characteristics of a new cone beam computed tomography Korean Journal of Oral and Maxillofacial Radiology 2007; 37 : 205-9 Characteristics of a new cone beam computed tomography Chang-Seo Park, Kee-Deog Kim, Hyok Park, Ho-Gul Jeong, Sang-Chul Lee* Department

More information

EVALUATION OF RADIATION HARDNESS DESIGN TECHNIQUES TO IMPROVE RADIATION TOLERANCE FOR CMOS IMAGE SENSORS DEDICATED TO SPACE APPLICATIONS

EVALUATION OF RADIATION HARDNESS DESIGN TECHNIQUES TO IMPROVE RADIATION TOLERANCE FOR CMOS IMAGE SENSORS DEDICATED TO SPACE APPLICATIONS EVALUATION OF RADIATION HARDNESS DESIGN TECHNIQUES TO IMPROVE RADIATION TOLERANCE FOR CMOS IMAGE SENSORS DEDICATED TO SPACE APPLICATIONS P. MARTIN-GONTHIER, F. CORBIERE, N. HUGER, M. ESTRIBEAU, C. ENGEL,

More information

Introduction. Chapter 1

Introduction. Chapter 1 1 Chapter 1 Introduction During the last decade, imaging with semiconductor devices has been continuously replacing conventional photography in many areas. Among all the image sensors, the charge-coupled-device

More information

Research Article Image Quality Assessment of a CMOS/Gd 2 O 2 S:Pr,Ce,F X-Ray Sensor

Research Article Image Quality Assessment of a CMOS/Gd 2 O 2 S:Pr,Ce,F X-Ray Sensor Sensors Volume 2015, Article ID 874637, 6 pages http://dx.doi.org/10.1155/2015/874637 Research Article Image Quality Assessment of a CMOS/Gd 2 O 2 S:Pr,Ce,F X-Ray Sensor Christos Michail Radiation Physics,

More information

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014 Detectors for microscopy - CCDs, APDs and PMTs Antonia Göhler Nov 2014 Detectors/Sensors in general are devices that detect events or changes in quantities (intensities) and provide a corresponding output,

More information

A flexible compact readout circuit for SPAD arrays ABSTRACT Keywords: 1. INTRODUCTION 2. THE SPAD 2.1 Operation 7780C - 55

A flexible compact readout circuit for SPAD arrays ABSTRACT Keywords: 1. INTRODUCTION 2. THE SPAD 2.1 Operation 7780C - 55 A flexible compact readout circuit for SPAD arrays Danial Chitnis * and Steve Collins Department of Engineering Science University of Oxford Oxford England OX13PJ ABSTRACT A compact readout circuit that

More information

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor Image acquisition Digital images are acquired by direct digital acquisition (digital still/video cameras), or scanning material acquired as analog signals (slides, photographs, etc.). In both cases, the

More information

Interpixel crosstalk in a 3D-integrated active pixel sensor for x-ray detection

Interpixel crosstalk in a 3D-integrated active pixel sensor for x-ray detection Interpixel crosstalk in a 3D-integrated active pixel sensor for x-ray detection The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Citation

More information

Active Pixel Sensors Fabricated in a Standard 0.18 um CMOS Technology

Active Pixel Sensors Fabricated in a Standard 0.18 um CMOS Technology Active Pixel Sensors Fabricated in a Standard.18 um CMOS Technology Hui Tian, Xinqiao Liu, SukHwan Lim, Stuart Kleinfelder, and Abbas El Gamal Information Systems Laboratory, Stanford University Stanford,

More information

ABSTRACT. Keywords: 0,18 micron, CMOS, APS, Sunsensor, Microned, TNO, TU-Delft, Radiation tolerant, Low noise. 1. IMAGERS FOR SPACE APPLICATIONS.

ABSTRACT. Keywords: 0,18 micron, CMOS, APS, Sunsensor, Microned, TNO, TU-Delft, Radiation tolerant, Low noise. 1. IMAGERS FOR SPACE APPLICATIONS. Active pixel sensors: the sensor of choice for future space applications Johan Leijtens(), Albert Theuwissen(), Padmakumar R. Rao(), Xinyang Wang(), Ning Xie() () TNO Science and Industry, Postbus, AD

More information

Digital Radiography : Flat Panel

Digital Radiography : Flat Panel Digital Radiography : Flat Panel Flat panels performances & operation How does it work? - what is a sensor? - ideal sensor Flat panels limits and solutions - offset calibration - gain calibration - non

More information

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893 Digital Radiography D. J. Hall, Ph.D. x20893 djhall@ucsd.edu Background Common Digital Modalities Digital Chest Radiograph - 4096 x 4096 x 12 bit CT - 512 x 512 x 12 bit SPECT - 128 x 128 x 8 bit MRI -

More information

Fully depleted, thick, monolithic CMOS pixels with high quantum efficiency

Fully depleted, thick, monolithic CMOS pixels with high quantum efficiency Fully depleted, thick, monolithic CMOS pixels with high quantum efficiency Andrew Clarke a*, Konstantin Stefanov a, Nicholas Johnston a and Andrew Holland a a Centre for Electronic Imaging, The Open University,

More information

THE CCD RIDDLE REVISTED: SIGNAL VERSUS TIME LINEAR SIGNAL VERSUS VARIANCE NON-LINEAR

THE CCD RIDDLE REVISTED: SIGNAL VERSUS TIME LINEAR SIGNAL VERSUS VARIANCE NON-LINEAR THE CCD RIDDLE REVISTED: SIGNAL VERSUS TIME LINEAR SIGNAL VERSUS VARIANCE NON-LINEAR Mark Downing 1, Peter Sinclaire 1. 1 ESO, Karl Schwartzschild Strasse-2, 85748 Munich, Germany. ABSTRACT The photon

More information

Simulation of High Resistivity (CMOS) Pixels

Simulation of High Resistivity (CMOS) Pixels Simulation of High Resistivity (CMOS) Pixels Stefan Lauxtermann, Kadri Vural Sensor Creations Inc. AIDA-2020 CMOS Simulation Workshop May 13 th 2016 OUTLINE 1. Definition of High Resistivity Pixel Also

More information

Investigation of Effective DQE (edqe) parameters for a flat panel detector

Investigation of Effective DQE (edqe) parameters for a flat panel detector Investigation of Effective DQE (edqe) parameters for a flat panel detector Poster No.: C-1892 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit D. Bor 1, S. Cubukcu 1, A. Yalcin 1, O.

More information

LARGE FORMATTED AND HIGH RESOLUTION CMOS FLAT PANEL SENSORS FOR X-RAY

LARGE FORMATTED AND HIGH RESOLUTION CMOS FLAT PANEL SENSORS FOR X-RAY The 8 th International Conference of the Slovenian Society for Non-Destructive Testing»Application of Contemporary Non-Destructive Testing in Engineering«September 1-3, 2005, Portorož, Slovenia, pp. 165-172

More information

CCDS. Lesson I. Wednesday, August 29, 12

CCDS. Lesson I. Wednesday, August 29, 12 CCDS Lesson I CCD OPERATION The predecessor of the CCD was a device called the BUCKET BRIGADE DEVICE developed at the Phillips Research Labs The BBD was an analog delay line, made up of capacitors such

More information

Properties of a Detector

Properties of a Detector Properties of a Detector Quantum Efficiency fraction of photons detected wavelength and spatially dependent Dynamic Range difference between lowest and highest measurable flux Linearity detection rate

More information

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA Gena M.A.H 1, Ahmed L.El-Attar 2, Elbadry M. Zahran 3, Hany El-Gamal

More information

Application of CMOS sensors in radiation detection

Application of CMOS sensors in radiation detection Application of CMOS sensors in radiation detection S. Ashrafi Physics Faculty University of Tabriz 1 CMOS is a technology for making low power integrated circuits. CMOS Complementary Metal Oxide Semiconductor

More information

Final Project: FEDX X-ray Radiation Detector

Final Project: FEDX X-ray Radiation Detector Final Project: FEDX X-ray Radiation Detector Keita Todoroki Keita Fukushima December 12, 2011 Introduction The application of radiation detectors has played an important role in physical science, especially

More information

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips Strip Detectors First detector devices using the lithographic capabilities of microelectronics First Silicon detectors -- > strip detectors Can be found in all high energy physics experiments of the last

More information

DALLA LUCE VISIBILE AI RAGGI X: NUOVI RIVELATORI DI IMMAGINI PER RAGGI X A DISCRIMINAZIONE IN ENERGIA ED APPLICAZIONI

DALLA LUCE VISIBILE AI RAGGI X: NUOVI RIVELATORI DI IMMAGINI PER RAGGI X A DISCRIMINAZIONE IN ENERGIA ED APPLICAZIONI DALLA LUCE VISIBILE AI RAGGI X: NUOVI RIVELATORI DI IMMAGINI PER RAGGI X A DISCRIMINAZIONE IN ENERGIA ED APPLICAZIONI D. Pacella ENEA - Frascati LIMS, Frascati 14-15 ottobre 2015 Come per la fotografia:

More information

STATUS AND PROSPECTS OF DIGITAL DETECTOR TECHNOLOGY FOR CR AND DR Ulrich Neitzel Philips Medical Systems, Röntgenstrasse 24, D Hamburg, Germany

STATUS AND PROSPECTS OF DIGITAL DETECTOR TECHNOLOGY FOR CR AND DR Ulrich Neitzel Philips Medical Systems, Röntgenstrasse 24, D Hamburg, Germany Radiation Protection Dosimetry (2005), Vol. 114, Nos 1-3, pp. 32 38 doi:10.1093/rpd/nch532 INVITED PAPER STATUS AND PROSPECTS OF DIGITAL DETECTOR TECHNOLOGY FOR CR AND DR Ulrich Neitzel Philips Medical

More information

Evaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure

Evaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure 1 Evaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure J. Metcalfe, D. E. Dorfan, A. A. Grillo, A. Jones, F. Martinez-McKinney,

More information

BASICS OF FLUOROSCOPY

BASICS OF FLUOROSCOPY Medical Physics Residents Training Program BASICS OF FLUOROSCOPY Dr. Khalid Alyousef, PhD Department of Medical Imaging King Abdulaziz Medical City- Riyadh Edison examining the hand of Clarence Dally with

More information

High collection efficiency MCPs for photon counting detectors

High collection efficiency MCPs for photon counting detectors High collection efficiency MCPs for photon counting detectors D. A. Orlov, * T. Ruardij, S. Duarte Pinto, R. Glazenborg and E. Kernen PHOTONIS Netherlands BV, Dwazziewegen 2, 9301 ZR Roden, The Netherlands

More information

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation Original Article PROGRESS in MEDICAL PHYSICS 27(3), Sept. 2016 http://dx.doi.org/10.14316/pmp.2016.27.3.125 pissn 2508-4445, eissn 2508-4453 Optimization of Energy Modulation Filter for Dual Energy CBCT

More information

7/24/2014. Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation. Disclosures. Outline

7/24/2014. Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation. Disclosures. Outline Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation Image Quality Review I: Basics and Image Quality TH-A-16A-1 Thursday 7:30AM - 9:30AM Room: 16A J. Anthony

More information

Development of the Pixelated Photon Detector. Using Silicon on Insulator Technology. for TOF-PET

Development of the Pixelated Photon Detector. Using Silicon on Insulator Technology. for TOF-PET July 24, 2015 Development of the Pixelated Photon Detector Using Silicon on Insulator Technology for TOF-PET A.Koyama 1, K.Shimazoe 1, H.Takahashi 1, T. Orita 2, Y.Arai 3, I.Kurachi 3, T.Miyoshi 3, D.Nio

More information

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Unit thickness. Unit area. σ = NΔX = ΔI / I 0 Unit thickness I 0 ΔI I σ = ΔI I 0 NΔX = ΔI / I 0 NΔX Unit area Δx Average probability of reaction with atom for the incident photons at unit area with the thickness of Delta-X Atom number at unit area

More information

Abstract. Preface. Acknowledgments

Abstract. Preface. Acknowledgments Contents Abstract Preface Acknowledgments iv v vii 1 Introduction 1 1.1 A Very Brief History of Visible Detectors in Astronomy................ 1 1.2 The CCD: Astronomy s Champion Workhorse......................

More information

Gamma Spectrometer Initial Project Proposal

Gamma Spectrometer Initial Project Proposal Gamma Spectrometer Initial Project Proposal Group 9 Aman Kataria Johnny Klarenbeek Dean Sullivan David Valentine Introduction There are currently two main types of gamma radiation detectors used for gamma

More information

CR Basics and FAQ. Overview. Historical Perspective

CR Basics and FAQ. Overview. Historical Perspective Page: 1 of 6 CR Basics and FAQ Overview Computed Radiography is a term used to describe a system that electronically records a radiographic image. Computed Radiographic systems use unique image receptors

More information

Geometric image distortion in flat-panel X-ray detectors and its influence on the accuracy of CT-based dimensional measurements

Geometric image distortion in flat-panel X-ray detectors and its influence on the accuracy of CT-based dimensional measurements Geometric image distortion in flat-panel X-ray detectors and its influence on the accuracy of CT-based dimensional measurements Daniel Weiß, Ronald Lonardoni, Andreas Deffner, Christoph Kuhn Carl Zeiss

More information

arxiv: v2 [physics.ins-det] 14 Jul 2015

arxiv: v2 [physics.ins-det] 14 Jul 2015 April 11, 2018 Compensation of radiation damages for SOI pixel detector via tunneling arxiv:1507.02797v2 [physics.ins-det] 14 Jul 2015 Miho Yamada 1, Yasuo Arai and Ikuo Kurachi Institute of Particle and

More information

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology CODE: RADT 156 INSTITUTE: Health Science TITLE: Equipment Operation I DEPARTMENT: Radiologic Technology COURSE DESCRIPTION: This course covers the principles of equipment operation and maintenance of radiographic

More information

INTRODUCTION: Basic operating principle of a MOSFET:

INTRODUCTION: Basic operating principle of a MOSFET: INTRODUCTION: Along with the Junction Field Effect Transistor (JFET), there is another type of Field Effect Transistor available whose Gate input is electrically insulated from the main current carrying

More information

AN INITIAL investigation into the effects of proton irradiation

AN INITIAL investigation into the effects of proton irradiation IEEE TRANSACTIONS ON ELECTRON DEVICES, VOL. 53, NO. 2, FEBRUARY 2006 205 Proton Irradiation of EMCCDs David R. Smith, Richard Ingley, and Andrew D. Holland Abstract This paper describes the irradiation

More information

DIGITAL IMAGE PROCESSING IN X-RAY IMAGING

DIGITAL IMAGE PROCESSING IN X-RAY IMAGING DIGITAL IMAGE PROCESSING IN X-RAY IMAGING Shalini Kumari 1, Bachan Prasad 2,Aliya Nasim 3 Department of Electronics And Communication Engineering R.V.S College of Engineering & Technology, Jamshedpur,

More information

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography ECNDT 26 - Poster 17 Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography Khairul Anuar MOHD SALLEH, Ab. Razak HAMZAH and Mohd Ashhar

More information

A new Photon Counting Detector: Intensified CMOS- APS

A new Photon Counting Detector: Intensified CMOS- APS A new Photon Counting Detector: Intensified CMOS- APS M. Belluso 1, G. Bonanno 1, A. Calì 1, A. Carbone 3, R. Cosentino 1, A. Modica 4, S. Scuderi 1, C. Timpanaro 1, M. Uslenghi 2 1-I.N.A.F.-Osservatorio

More information

PERFORMANCE MEASUREMENT OF MEDICAL IMAGING SYSTEMS BASED ON MUTUAL INFORMATION METRIC

PERFORMANCE MEASUREMENT OF MEDICAL IMAGING SYSTEMS BASED ON MUTUAL INFORMATION METRIC XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal PERFORMANCE MEASUREMENT OF MEDICAL IMAGING SYEMS BASED ON MUTUAL INFORMATION METRIC Eri Matsuyama 1, Du-Yih

More information

Southern Methodist University Dallas, TX, Department of Physics. Southern Methodist University Dallas, TX, 75275

Southern Methodist University Dallas, TX, Department of Physics. Southern Methodist University Dallas, TX, 75275 Total Ionization Dose Effect Studies of a 0.25 µm Silicon-On-Sapphire CMOS Technology Tiankuan Liu 2, Ping Gui 1, Wickham Chen 1, Jingbo Ye 2, Cheng-AnYang 2, Junheng Zhang 1, Peiqing Zhu 1, Annie C. Xiang

More information

Features and Weaknesses of Phantoms for CR/DR System Testing

Features and Weaknesses of Phantoms for CR/DR System Testing Physics testing of image detectors Parameters to test Features and Weaknesses of Phantoms for CR/DR System Testing Spatial resolution Contrast resolution Uniformity/geometric distortion Dose response/signal

More information

radiography detector

radiography detector Clinical evaluation of a full field digital projection radiography detector Gary S. Shaber'1, Denny L. Leeb, Jeffrey Belib, Gregory Poweii1', Andrew D.A. Maidment'1 a Thomas Jefferson University Hospital,

More information

BACKSIDE ILLUMINATED CMOS-TDI LINE SCANNER FOR SPACE APPLICATIONS

BACKSIDE ILLUMINATED CMOS-TDI LINE SCANNER FOR SPACE APPLICATIONS BACKSIDE ILLUMINATED CMOS-TDI LINE SCANNER FOR SPACE APPLICATIONS O. Cohen, N. Ben-Ari, I. Nevo, N. Shiloah, G. Zohar, E. Kahanov, M. Brumer, G. Gershon, O. Ofer SemiConductor Devices (SCD) P.O.B. 2250,

More information

Digital camera. Sensor. Memory card. Circuit board

Digital camera. Sensor. Memory card. Circuit board Digital camera Circuit board Memory card Sensor Detector element (pixel). Typical size: 2-5 m square Typical number: 5-20M Pixel = Photogate Photon + Thin film electrode (semi-transparent) Depletion volume

More information

Moderne Teilchendetektoren - Theorie und Praxis 2. Dr. Bernhard Ketzer Technische Universität München SS 2013

Moderne Teilchendetektoren - Theorie und Praxis 2. Dr. Bernhard Ketzer Technische Universität München SS 2013 Moderne Teilchendetektoren - Theorie und Praxis 2 Dr. Bernhard Ketzer Technische Universität München SS 2013 7 Signal Processing and Acquisition 7.1 Signals 7.2 Amplifier 7.3 Electronic Noise 7.4 Analog-to-Digital

More information

Semiconductor Physics and Devices

Semiconductor Physics and Devices Metal-Semiconductor and Semiconductor Heterojunctions The Metal-Oxide-Semiconductor Field-Effect Transistor (MOSFET) is one of two major types of transistors. The MOSFET is used in digital circuit, because

More information

CCD Characteristics Lab

CCD Characteristics Lab CCD Characteristics Lab Observational Astronomy 6/6/07 1 Introduction In this laboratory exercise, you will be using the Hirsch Observatory s CCD camera, a Santa Barbara Instruments Group (SBIG) ST-8E.

More information

Solid State Photomultiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification

Solid State Photomultiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification Solid State Photomultiplier: Noise Parameters of Photodetectors with Internal Discrete Amplification K. Linga, E. Godik, J. Krutov, D. Shushakov, L. Shubin, S.L. Vinogradov, and E.V. Levin Amplification

More information

Rad-icon Imaging Corp A Division of DALSA Corporation

Rad-icon Imaging Corp A Division of DALSA Corporation Rad-icon Imaging Corp A Division of DALSA Corporation el: 408-486-0886 Fax: 408-486-0882 www.rad-icon.com PRELIMINARY DAA SHEE SkiaGraph 8 Very Large Area X-Ray Camera Key Features: Active area of 20 cm

More information

Design and Simulation of a Silicon Photomultiplier Array for Space Experiments

Design and Simulation of a Silicon Photomultiplier Array for Space Experiments Journal of the Korean Physical Society, Vol. 52, No. 2, February 2008, pp. 487491 Design and Simulation of a Silicon Photomultiplier Array for Space Experiments H. Y. Lee, J. Lee, J. E. Kim, S. Nam, I.

More information

Jan Bogaerts imec

Jan Bogaerts imec imec 2007 1 Radiometric Performance Enhancement of APS 3 rd Microelectronic Presentation Days, Estec, March 7-8, 2007 Outline Introduction Backside illuminated APS detector Approach CMOS APS (readout)

More information

Charge-integrating organic heterojunction

Charge-integrating organic heterojunction In the format provided by the authors and unedited. DOI: 10.1038/NPHOTON.2017.15 Charge-integrating organic heterojunction Wide phototransistors dynamic range for organic wide-dynamic-range heterojunction

More information

EE 392B: Course Introduction

EE 392B: Course Introduction EE 392B Course Introduction About EE392B Goals Topics Schedule Prerequisites Course Overview Digital Imaging System Image Sensor Architectures Nonidealities and Performance Measures Color Imaging Recent

More information

X-ray Radiation Hardness of Fully-Depleted SOI MOSFETs and Its Improvement

X-ray Radiation Hardness of Fully-Depleted SOI MOSFETs and Its Improvement June 4, 2015 X-ray Radiation Hardness of Fully-Depleted SOI MOSFETs and Its Improvement Ikuo Kurachi 1, Kazuo Kobayashi 2, Hiroki Kasai 3, Marie Mochizuki 4, Masao Okihara 4, Takaki Hatsui 2, Kazuhiko

More information

CCD Analogy BUCKETS (PIXELS) HORIZONTAL CONVEYOR BELT (SERIAL REGISTER) VERTICAL CONVEYOR BELTS (CCD COLUMNS) RAIN (PHOTONS)

CCD Analogy BUCKETS (PIXELS) HORIZONTAL CONVEYOR BELT (SERIAL REGISTER) VERTICAL CONVEYOR BELTS (CCD COLUMNS) RAIN (PHOTONS) CCD Analogy RAIN (PHOTONS) VERTICAL CONVEYOR BELTS (CCD COLUMNS) BUCKETS (PIXELS) HORIZONTAL CONVEYOR BELT (SERIAL REGISTER) MEASURING CYLINDER (OUTPUT AMPLIFIER) Exposure finished, buckets now contain

More information

Control of Noise and Background in Scientific CMOS Technology

Control of Noise and Background in Scientific CMOS Technology Control of Noise and Background in Scientific CMOS Technology Introduction Scientific CMOS (Complementary metal oxide semiconductor) camera technology has enabled advancement in many areas of microscopy

More information

Silicon Photodiodes - SXUV Series with Platinum Silicide Front Entrance Windows

Silicon Photodiodes - SXUV Series with Platinum Silicide Front Entrance Windows Silicon Photodiodes - SXUV Series with Platinum Silicide Front Entrance Windows SXUV Responsivity Stability It is known that the UV photon exposure induced instability of common silicon photodiodes is

More information

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE A. Miceli ab, R. Thierry a, A. Flisch a, U. Sennhauser a, F. Casali b a Empa - Swiss Federal Laboratories for

More information

Design and Simulation of N-Substrate Reverse Type Ingaasp/Inp Avalanche Photodiode

Design and Simulation of N-Substrate Reverse Type Ingaasp/Inp Avalanche Photodiode International Refereed Journal of Engineering and Science (IRJES) ISSN (Online) 2319-183X, (Print) 2319-1821 Volume 2, Issue 8 (August 2013), PP.34-39 Design and Simulation of N-Substrate Reverse Type

More information

Setting up digital imaging department!

Setting up digital imaging department! Outline Setting up digital imaging department! From screen/film to digital radiography PACS/Tele radiology Setting up digital department Digital Imaging Napapong Pongnapang, Ph.D. Department of Radiological

More information

Seminar 8. Radiology S8 1

Seminar 8. Radiology S8 1 Seminar 8 Radiology Medical imaging. X-ray image formation. Energizing and controlling the X-ray tube. Image detectors. The acquisition of analog and digital images. Digital image processing. Selected

More information

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto X-ray Imaging PHYS Lecture Carlos Vinhais Departamento de Física Instituto Superior de Engenharia do Porto cav@isep.ipp.pt Overview Projection Radiography Anode Angle Focal Spot Magnification Blurring

More information