City of Rawlins, Wyoming

Size: px
Start display at page:

Download "City of Rawlins, Wyoming"

Transcription

1 City of Rawlins, Wyoming 00% DESIGN INTENT DRAWINGS May 3, 04

2 Section SIGN SYSTEM STANDARDS A. Graphic Standards Typography Specifications... A. Vehicular Terminologies... A.5 Project Artwork... A.6 Typical Vehicular Back Panel Graphics... A.7 Reflective and Opaque Vinyl Color Chart... A.8 Paint and Material Color Chart... A.9 B. Placement Guidelines Vehicular Signage... B. Lateral Clearance... B.4 E. Graphic Layouts VDIR E. VDIR E. PARK.3... E.3 DEST... E.4 DEST... E.5 DEST.3... E.6 DEST.4... E.7 PDIR... E.8 INTERP... E.9 INTERP... E.0 Section SIGNAGE DRAWINGS C. Menu of Sign Types Gateways and Identification... C. Vehicular... C. Parking... C.3 Pedestrian... C.4 D. Design Intent Drawings GTWY. Gateway Identification... D. VDIR. Vehicular Directional... D.3 VDIR. Vehicular Directional... D.4 VDIR.3 Vehicular Directional... D.5 VDIR.4 Vehicular Directional... D.6 VDIR.5 Vehicular Directional... D.7 VDIR.6 Vehicular Directional... D.8 PARK.A Parking Trailblazer... D.9 PARK.B Parking Trailblazer... D.0 PARK. Parking Trailblazer... D. PARK.3 Parking Identification... D. DEST. Identification... D.3 DEST. Identification... D.4 DEST.3 Identification... D.5 DEST.4 Identification... D.6 PDIR. Pedestrian Directional... D.7 KIOSK. Pedestrian Kiosk... D.8 INTERP. Interpretive - Small... D.9 INTERP. Interpretive - Large... D. F. Construction Details GTWY. Section Details... F. VDIR.-3 Section Details... F. VDIR.4-6, DEST.3 Section Details... F.3 PARK.3 Section Details... F.4 PDIR. Section Details... F.5 DEST.- Section Details... F.6 DEST.4 Section Details... F.7 KIOSK. Section Details... F.8 VDIR.-6 Post Cuff Details... F.9 TRANSPO B55 Break-Safe... F.0 TRANSPO AS4 Break-Safe... F. Plate-To-Plate Footer... F.4 Sidewalk Footer Placement... F.5 G. Performance Specifications General... G. Product... G.3 Execution... G.6 Table of Contents

3 A Graphic Standards

4 SPECIFICATIONS Clearview Highway ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz The Clearview typeface is the required message font for vehicular sign types VDIR.-6, and PARK.-3. All type shall be set exactly as specified. Substitutions will only be accepted, at the DESIGNER S discretion, where they match the specified typeface in every detail. The FABRICATOR should be aware that different versions of typesetting equipment may not satisfactorily match specified typefaces and in such instances will not be acceptable. Amongst the several mechanical Arts that have engaged my attention, there is no one which I have pursued with so much steadiness and pleasure, as that of Letter Founding. Downtown Downtown Downtown acceptable NOT acceptable NOT acceptable 3A 3A 3A acceptable NOT acceptable NOT acceptable Sometimes the Foot mark is mistaken for an apostrophe and an inch mark is mistaken for quotations. Below are examples of correct and incorrect apostrophe s for each typeface. NOTES Clearview Highway ' This apostrophe is CORRECT. PARK S This apostrophe is INCORRECT. PARK'S The Clearview typeface is the required message font for vehicular sign types VDIR.-6, and PARK.-3. CLIENT / OJECT SUBCONSULTANT OJECT NO. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Typography Specifications A.

5 Gotham Book ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz Amongst the several mechanical Arts that have engaged my attention, there is no one which I have pursued with so much steadiness and pleasure, as that of Letter Founding. SPECIFICATIONS The Gotham Book and Bold typefaces are utilized for messages on pedestrian and destination identification sign types, and for secondary messages on gateway signs. All type shall be set exactly as specified. Substitutions will only be accepted, at the DESIGNER S discretion, where they match the specified typeface in every detail. The FABRICATOR should be aware that different versions of typesetting equipment may not satisfactorily match specified typefaces and in such instances will not be acceptable. Downtown Downtown Downtown acceptable NOT acceptable NOT acceptable 3A 3A 3A acceptable NOT acceptable NOT acceptable Gotham Bold ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz !@#$%^ Amongst the several mechanical Arts that have engaged my attention, there is no one which I have pursued with so much steadiness and pleasure, as that of Letter Founding. Downtown Downtown Downtown acceptable NOT acceptable NOT acceptable 3A 3A 3A acceptable NOT acceptable NOT acceptable NOTES The Gotham Bold typeface is utilized for messages on pedestrian and destination identification sign types, and for secondary messages on gateway signs. The Horndon typeface is utilized for the City of Rawlins identity only. SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Typography Specifications A.

6 Rockwell Regular ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz Amongst the several mechanical Arts that have engaged my attention, there is no one which I have pursued with so much steadiness and pleasure, as that of Letter Founding. SPECIFICATIONS The Rockwell Regular and Bold typefaces are utilized for pedestrian interpretive sign types only. All type shall be set exactly as specified. Substitutions will only be accepted, at the DESIGNER S discretion, where they match the specified typeface in every detail. The FABRICATOR should be aware that different versions of typesetting equipment may not satisfactorily match specified typefaces and in such instances will not be acceptable. Downtown Downtown Downtown acceptable NOT acceptable NOT acceptable 3A 3A 3A acceptable NOT acceptable NOT acceptable Rockwell BOld ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz !@#$%^ Amongst the several mechanical Arts that have engaged my attention, there is no one which I have pursued with so much steadiness and pleasure, as that of Letter Founding. Downtown Downtown Downtown acceptable NOT acceptable NOT acceptable 3A 3A 3A acceptable NOT acceptable NOT acceptable NOTES The Rockwell Regular and Bold typefaces are utilized for pedestrian interpretive sign types only. SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Typography Specifications A.3

7 LETTER-SPACING Inconsistencies in Letter Spacing Corrected Letter Spacing SPECIFICATIONS Individual spacing of each letter needs to be evaluated. All copy shall be kerned so that each character is optically centered between the center of each of the surrounding characters. TYPEFACE TYPEFACE Rawlins Rawlins TYPEFACE TYPEFACE Rawlins Rawlins IMPORTANT: Individual spacing of each letter needs to be evaluated. See Examples Above. Kern all Copy so that each character is optically centered between the center of each of the surrounding characters. SIGN TEXT STANDARDS COPY HEIGHT LINE SPACING NOTES When measuring copy height, measure only the height of the Capital letters to determine your overall copy height (shown in illustration below as X ) Some of the other letters have an extended height beyond the average height of the letters. X EjklH baseline X When measuring line spacing, always measure from the baseline of the topmost text line to the baseline of the text line below (shown as X ) EjklH EjklH baseline baseline SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Typography Specifications A.4

8 SPECIFICATIONS 3" 3'-6" Vehicular Panel Width VISITOR SERVICES COMMUNITY / GOVERNMENT TRANSPORTATION PARKS Terminology shown represents graphic breaks for Vehicular Directional signs with 4 inch high copy. ALL TYPE SHALL BE SET EXACTLY AS SPECIFIED. 4" Chamber of Commerce City Hall Courthouse Airport Bolten Park Depot Park Visitor Info Center ATTRACTIONS Carbon County Museum Downtown Fairgrounds The Depot Wyoming Frontier Prison Library Post Office Recreation Center Senior Center PUBLIC GOLF COURSES Rochelle Ranch Golf Course OUTDOOR SPORTS Sports Complex Indoor Shooting Range Outdoor Shooting Cmplx Walking Path TRAILBLAZERS Key Club Park Rawlins Springs Park Rob Roy Park Rodeo Park Tully Park Washington Park HIGHWAY ACCESS NOTES The Owner, and destination shown, shall verify all terminology and abbreviations are accurate. Memorial Hospital Carbon County Rawlins Municipal Airport Rochelle Ranch Golf Course CLIENT / OJECT OJECT NO. SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Vehicular Terminologies A.5

9 SPECIFICATIONS GRAPHIC ELEMENTS All artwork pictured on this page will be provided to the sign fabricator by the designer and/or client. This artwork must be used for all sign applications in this provided documentation. Do NOT substitute with any other artwork! SYMBOLS USE of Arrows Picnic Tables Electricity Pavilion Restrooms Disc Golf Drinking Fountain Grilling Dogs Allowed Horseshoes Basketball Tennis Courts Children s Playground When multiple directions are required on a sign, the following directional hierarchy shall take precedent. See Example below. Reference Schedule for individual s. Straight Arrow Parking Left Arrow ARROWS Right Arrow NOTES Left Arrow Up-Left Arrow Straight Arrow Up-Right Arrow Right Arrow SUBCONSULTANT CLIENT / OJECT OJECT NO. Straight-Left Arrow Up-Straight-Left Arrow Up-Straight-Right Arrow Straight-Right Arrow These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Project Artwork A.6

10 SPECIFICATIONS Typical Back Panel Graphics For Vehicular Signs: VDIR.-3 This page is provided to help illustrate the intent of how the printed vinyl graphics apply to the backs of the vehicular sign types. The applications apply to sign types VDIR. 6 only. Sign Panel Back View Uplift Panel Back View Uplift Panel Side View Uplift Panel Flat View Typical Back Panel Graphics For Vehicular Signs: VDIR.4-6 NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT SUBCONSULTANT OJECT NO. Sign Panel Back View Uplift Panel Back View Uplift Panel Side View Uplift Panel Flat View These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Typical Vehicular Back Panel Graphics A.7

11 R REFLECTIVE VINYL NAME SPECIFICATION APPLICABLE OCESS R R Rawlins White Rawlins Blue 3M High Intensity Prismatic Reflective Sheeting 3930 Color: White 3M High Intensity Prismatic Reflective Sheeting 3930 Color Match: BM Paint HC-54 Hale Navy Standard for System (typ.) Standard for System (typ.) Knockout White: Background and Characters 3M custom inks direct to 3930 with 3M approved Clear UV/Graffiti overlaminate. *Applied according to Manufacturers Spec to aluminum sheet. Custom Color: Background and Characters 3M custom inks direct to 3930 with 3M approved Clear UV/Graffiti overlaminate. *Applied according to Manufacturers Spec to aluminum sheet. SPECIFICATIONS The FABRICATOR must submit three (3) identical sets of each color specified for approval prior to any painting. Sample paint swatches must be produced on.080" aluminum sheet, approximately 3" x 6", including primer and free of defects. Sample material swatches should be the same approximate size. Samples MUST have project and color specifications attached to back side. R3 R4 Rawlins Red Rawlins Green 3M High Intensity Prismatic Reflective Sheeting 3930 Color Match: BM Paint M High Intensity Prismatic Reflective Sheeting 3930 Color Match: BM Paint 45-0 Avocado Standard for System (typ.) Standard for System (typ.) Custom Color: Background and Characters 3M custom inks direct to 3930 with 3M approved Clear UV/Graffiti overlaminate. *Applied according to Manufacturers Spec to aluminum sheet. Custom Color: Background and Characters 3M custom inks direct to 3930 with 3M approved Clear UV/Graffiti overlaminate. *Applied according to Manufacturers Spec to aluminum sheet. The colors must look exactly the same every time they are used so that people associate them with the Rawlins Wayfinding Program. All media, vinyl, paint, and inks must be produced so that the colors match as specified on this page. R5 Rawlins Gold 3M High Intensity Prismatic Reflective Sheeting 3930 Color Match: BM Paint 54-0 Yellow Oxide Standard for System (typ.) Custom Color: Background and Characters 3M custom inks direct to 3930 with 3M approved Clear UV/Graffiti overlaminate. *Applied according to Manufacturers Spec to aluminum sheet. R6 Gray 3M High Intensity Prismatic Reflective Sheeting 3930 Color Match: BM Paint HC-76 Davenport Tan Standard for System (typ.) Custom Color: Background and Characters 3M custom inks direct to 3930 with 3M approved Clear UV/Graffiti overlaminate. *Applied according to Manufacturers Spec to aluminum sheet. R7 Gray 3M High Intensity Prismatic Reflective Sheeting 3930 Color Match: BM Paint HC-68 Middlebury Brown Standard for System (typ.) Custom Color: Background and Characters 3M custom inks direct to 3930 with 3M approved Clear UV/Graffiti overlaminate. *Applied according to Manufacturers Spec to aluminum sheet. R8 Gray 3 3M High Intensity Prismatic Reflective Sheeting 3930 Color Match: BM Paint 5-0 Appalachian Brown Standard for System (typ.) Custom Color: Background and Characters 3M custom inks direct to 3930 with 3M approved Clear UV/Graffiti overlaminate. *Applied according to Manufacturers Spec to aluminum sheet. R9 Off-White 3M High Intensity Prismatic Reflective Sheeting 3930 Color Match: Pantone 7500C Standard for System (typ.) Custom Color: Background and Characters 3M custom inks direct to 3930 with 3M approved Clear UV/Graffiti overlaminate. *Applied according to Manufacturers Spec to aluminum sheet. * MUST comply with MUTCD section Table A-3 Minimum maintained retroreflectivity levels. Approved process: Durst RHO 6 TS printer. Sherine Industries: (604) NOTE: All 3M products are to be processed and applied according to 3M specifications. The seaming of material is NOT preferred. If the height of a sign panel is greater then 48 inches, the 3M 3930 material should be oriented vertically with stripes at 0 degrees, to avoid the seaming of material. If seaming is required, it should occur at the rule line or between messages. V VINYL NAME SPECIFICATION APPLICABLE OCESS V White 3M Scotchcal ElectroCut Opaque Vinyl Film White Standard for System (typ.) Surface applied according to 3M manufacturers specifications. V Rawlins Blue Color Match: BM Paint HC-54 Hale Navy Standard for System (typ.) High resolution printed on White 3M Scotchcal Opaque Vinyl with 3M approved Clear UV/Graffiti overlaminate. Surface applied according to 3M manufacturers specifications. V3 Rawlins Red Color Match: BM Paint Standard for System (typ.) High resolution printed on White 3M Scotchcal Opaque Vinyl with 3M approved Clear UV/Graffiti overlaminate. Surface applied according to 3M manufacturers specifications. V4 Rawlins Green Color Match: BM Paint 45-0 Avocado Standard for System (typ.) High resolution printed on White 3M Scotchcal Opaque Vinyl with 3M approved Clear UV/Graffiti overlaminate. Surface applied according to 3M manufacturers specifications. V5 Rawlins Gold Color Match: BM Paint 54-0 Yellow Oxide Standard for System (typ.) High resolution printed on White 3M Scotchcal Opaque Vinyl with 3M approved Clear UV/Graffiti overlaminate. Surface applied according to 3M manufacturers specifications. V6 Grey Color Match: BM Paint HC-76 Davenport Tan Standard for System (typ.) High resolution printed on White 3M Scotchcal Opaque Vinyl with 3M approved Clear UV/Graffiti overlaminate. Surface applied according to 3M manufacturers specifications. V7 Grey Color Match: BM Paint HC-68 Middlebury Brown Standard for System (typ.) High resolution printed on White 3M Scotchcal Opaque Vinyl with 3M approved Clear UV/Graffiti overlaminate. Surface applied according to 3M manufacturers specifications. NOTES V8 Grey 3 Color Match: BM Paint 5-0 Appalachian Brown Standard for System (typ.) High resolution printed on White 3M Scotchcal Opaque Vinyl with 3M approved Clear UV/Graffiti overlaminate. Surface applied according to 3M manufacturers specifications. V9 V0 Off-White Black 3M Scotchcal ElectroCut Opaque Vinyl Film Fawn 3M Scotchcal ElectroCut Opaque Vinyl Film 775- Natural Black Standard for System (typ.) Standard for System (typ.) High resolution printed on White 3M Scotchcal Opaque Vinyl with 3M approved Clear UV/Graffiti overlaminate. Surface applied according to 3M manufacturers specifications. Surface applied according to 3M manufacturers specifications. CLIENT / OJECT OJECT NO. SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Reflective and Opaque Vinyl Color Chart A.8

12 SPECIFICATIONS P PAINTS NAME SPECIFICATION APPLICABLE OCESS Surface applied, exterior sign paint and protective top coat: P White Matthews Paint MP 477 Standard for System (typ.) MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. P P3 P4 Rawlins Blue Rawlins Red Rawlins Green To match Benjamin Moore Paint HC-54 Hale Navy To match Benjamin Moore Paint Brick Red To match Benjamin Moore Paint 45-0 Avocado Standard for System (typ.) Standard for System (typ.) Standard for System (typ.) Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. The FABRICATOR must submit three (3) identical sets of each color specified for approval prior to any painting. Sample paint swatches must be produced on.080" aluminum sheet, approximately 3" x 6", including primer and free of defects. Sample material swatches should be the same approximate size. Samples MUST have project and color specifications attached to back side. The colors must look exactly the same every time they are used so that people associate them with the Rawlins Wayfinding Program. All media, vinyl, paint, and inks must be produced so that the colors match as specified on this page. P5 Rawlins Gold To match Benjamin Moore Paint 54-0 Yellow Oxide Standard for System (typ.) Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. P6 Gray To match Benjamin Moore Paint HC-76 Davenport Tan Standard for System (typ.) Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. P7 Gray To match Benjamin Moore Paint HC-68 Middlebury Brown Standard for System (typ.) Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. P8 Gray 3 To match Benjamin Moore Paint 5-0 Appalachian Brown Standard for System (typ.) Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. P9 Gray 4 TIGER Drylac Powder Coating RAL /6009 Posts - Standard for System (typ.) Surface applied, two-coat process: FINE Textured TIGER Drylac Series 38 Super Durable Polyester Powder Coating. P0 Off-White To match Pantone 7500C Standard for System (typ.) Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. P Black Stallion Matthews Paint MP Standard for System (typ.) Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. P Light Silver Metallic Matthews Paint MP 807 Standard for System (typ.) Surface applied, exterior sign paint and protective top coat: MATTHEWS Acrylic Polyurethane with Clear Coat Satin finish. M MATERIALS NAME SPECIFICATION OCESS M Dark Weathered Red Cedar Highwood Synthetic Wood. Color: Mohagany Extruded, solid, non-toxic synthetic wood. M Western Red Cedar Western Red Cedar x6 planks, ROUGH-CUT Locally sourced, rough-cut wood planks, natural finish. M3 Stone Quarry Buff + Pink/Buff (Quality Building Stone Inc.) Quarry block mix (3 5/8, 7 5/8, 5/8), 4 inch depth, Ashler pattern. Pink grout, Beaded appearance. M4 Stone Concrete Cap Cap for stone structures Mold-formed concrete slabs with coloring added. M5 Aluminum Pin-mounted (non-corrosive) individual aluminum letters Clear anodizing over natural aluminum finish NOTES M6 Phenolic Resin Panel dhpl exterior grade Hi resolution CMYK printed graphics set into phenolic resin exterior grade panels. CLIENT / OJECT SUBCONSULTANT OJECT NO. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Paint and Materials Color Chart A.9

13 B Placement Guidelines

14 Figure Sign A: VDIR. 6 B Figure Sign B: DEST. or PARK. Parking Lot SPECIFICATIONS FIGURE - Vehicular Directional - Sign Placement Guideline FIGURE - Arrival or Parking Identification - Sign Placement Guideline Unless approved by the Client or its designated agent, all signs shall be installed to the right of the direction of traffic and where sufficient space is available. (a) Signs shall be located to take advantage of natural terrain, to minimize impacts on scenic environment and to avoid visual conflicts with other signs, trees and lampposts within the City right-of-way. A A 00 to 00 ft. Priority placement Not less than 50 ft. Not less than 5 ft. Distance between signs 50 to 00 ft. 50 to 00 ft. Entrance B (b) Signs shall be located so as not to interfere with, obstruct or divert driver s attention from any other Official Traffic Control Device. Other Official Traffic Control Devices placed at intersection approaches, subsequent to the placement of a Wayfinding Sign, shall have precedence as to location and may require the relocation of the Wayfinding Sign. In the locations where Official Traffic Control Devices are integrated into the Wayfinding Signage System, the Official Traffic Control Devices shall take precedence with regard to order, space and location, over other information. (c) Wayfinding Signs shall be positioned in such a manner that does not restrict driver s attention or view when making turns or driving through an intersection. (d) There shall be a goal of one sign per block, although two are permissible, where necessary. The following pages illustrate installation guidelines for the location and spacing of the various sign types. Figures through 6 represent the guidelines for the location of the various sign types, while Figure 7 illustrates the lateral clearance guidelines. NOTES CLIENT / OJECT SUBCONSULTANT OJECT NO. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Placement Guidelines B.

15 Figure 3 Sign C: VDIR.4-6 Position Center of Island Figure 4 Sign D: VDIR.-6 SPECIFICATIONS FIGURE 3 - Vehicular Directional - Sign Placement Guideline FIGURE 4 - Vehicular Directional - Sign Placement Guideline Unless approved by the Client or its designated agent, all signs shall be installed to the right of the direction of traffic and where sufficient space is available. (a) Signs shall be located to take advantage of natural terrain, to minimize impacts on scenic environment and to avoid visual conflicts with other signs, trees and lampposts within the City right-of-way. C C Not less than5 ft. Not less than 5 ft. 00 to 00 ft. Not less than 5 ft. Not less than 50 ft. D D D Not less than 5 ft. Not less than 50 ft. (b) Signs shall be located so as not to interfere with, obstruct or divert driver s attention from any other Official Traffic Control Device. Other Official Traffic Control Devices placed at intersection approaches, subsequent to the placement of a Wayfinding Sign, shall have precedence as to location and may require the relocation of the Wayfinding Sign. In the locations where Official Traffic Control Devices are integrated into the Wayfinding Signage System, the Official Traffic Control Devices shall take precedence with regard to order, space and location, over other information. (c) Wayfinding Signs shall be positioned in such a manner that does not restrict driver s attention or view when making turns or driving through an intersection. (d) There shall be a goal of one sign per block, although two are permissible, where necessary. The following pages illustrate installation guidelines for the location and spacing of the various sign types. Figures through 6 represent the guidelines for the location of the various sign types, while Figure 7 illustrates the lateral clearance guidelines. NOTES D SUBCONSULTANT CLIENT / OJECT OJECT NO. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Placement Guidelines B.

16 Figure 5 Sign E: GATEWAY or DISTRICT SPECIFICATIONS FIGURE 5 - Gateway/District Arrival-Vehicular - Sign Placement Guideline Unless approved by the Client or its designated agent, all signs shall be installed to the right of the direction of traffic and where sufficient space is available. (a) Signs shall be located to take advantage of natural terrain, to minimize impacts on scenic environment and to avoid visual conflicts with other signs, trees and lampposts within the City right-of-way. Position Center of Island Existing Light Pole (b) Signs shall be located so as not to interfere with, obstruct or divert driver s attention from any other Official Traffic Control Device. Other Official Traffic Control Devices placed at intersection approaches, subsequent to the placement of a Wayfinding Sign, shall have precedence as to location and may require the relocation of the Wayfinding Sign. In the locations where Official Traffic Control Devices are integrated into the Wayfinding Signage System, the Official Traffic Control Devices shall take precedence with regard to order, space and location, over other information. (c) Wayfinding Signs shall be positioned in such a manner that does not restrict driver s attention or view when making turns or driving through an intersection. (d) There shall be a goal of one sign per block, although two are permissible, where necessary. The following pages illustrate installation guidelines for the location and spacing of the various sign types. Figures through 6 represent the guidelines for the location of the various sign types, while Figure 7 illustrates the lateral clearance guidelines. Banners Banners on Utility Poles Not less than 5 ft. E Not less than 5 ft. E NOTES District or City Boundary SUBCONSULTANT CLIENT / OJECT OJECT NO. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Placement Guidelines B.3

17 SPECIFICATIONS SIGN TYPE a MEASURE EFFERED DISTANCE MINIMUM DISTANCE Distance from Edge of Sign Panel to Edge of Curb '-0" or more ' - 0" FIGURE 6 - Lateral Clearance Guidelines Within some of the Downtown areas of Rawlins, urban conditions and narrow sidewalks may cause deviation from the standards articulated in the previous figures. Conditions may include less lateral clearance for the '-0" or 5'-0" preferred distance from edge of sign panel to curb, or placement at '-0" or 5'-0" would create an obstacle (i.e. post positioned in middle of the side walk) or create situations of non-compliance to ADA clearances. b Distance from Sign Post to Nearest Obstruction 4' - 0" or more 3' - 0" In these cases guidelines must be consistent with MUTCD Section A.9 options for urban areas. Suggested recommendations for relocation of signs if placement is in conflict with guidelines. Figure 6 Not to Scale c d e f Distance from Edge of Sign Panel to 4' - 0" or more ' - 0" Nearest Overhead Obstruction Sign Placement in Relation to Adjacent Building Distance from Face of Sign to Nearest Tree Branch Distance from Face of Sign to Nearest Utlity Pole align to building Edge 0' - 0" or more 5' - 0" 5' - 0" or more 0' - 0" Do Not obstruct Entrance OPTION A: Position the sign at a minimum of '-0" or 5'-0" (face of curb to edge of sign panel) as required. OPTION B: If the sign can be moved, without disrupting routing or sequencing, then it should be repositioned to achieve the '-0" or 5'-0" min. If '-0" is not physically possible, then the following options should be allowed: OPTION C: The sign set back should be position at '-6". If that is not possible then... OPTION D: Utilize a minimum '- 0", in accordance with MUTCD, only as a final option. g Distance from Back of Sign to Nearest Tree Branch 8' - 0" or more 3' - 0" g h b c h Distance from Back of Sign to Nearest Utility Pole 5' - 0" or more 0' - 0" Measurements and Distances shown are guidelines only prevailing local and state codes shall supersede information presented. NOTES CLIENT / OJECT a e f OJECT NO. SUBCONSULTANT d These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Placement Guidelines B.4

18 SPECIFICATIONS FIGURE 7 - Lateral Clearance Guidelines Gutter Curb Example of Sidewalk & City Right of Way (Sidewalk widths vary) Within some of the Downtown areas of Rawlins, urban conditions and narrow sidewalks may cause deviation from the standards articulated in the previous figures. Conditions may include less lateral clearance for the '-0" or 5'-0" preferred distance from edge of sign panel to curb, or placement at '-0" or 5'-0" would create an obstacle (i.e. post positioned in middle of the side walk) or create situations of non-compliance to ADA clearances. In these cases guidelines must be consistent with MUTCD Section A.9 options for urban areas. Suggested recommendations for relocation of signs if placement is in conflict with guidelines. OPTION A: Position the sign at a minimum of '-0" or 5'-0" (face of curb to edge of sign panel) as required. OPTION B: If the sign can be moved, without disrupting routing or sequencing, then it should be repositioned to achieve the '-0" or 5'-0" min. If '-0" is not physically possible, then the following options should be allowed: ADA required 3'-0" minimum Sidewalk Element: Canopy, Bench, Tree-grate Stairs, Building Entrance, etc. OPTION C: The sign set back should be position at '-6". If that is not possible then... OPTION D: Utilize a minimum '- 0", in accordance with MUTCD, only as a final option. -0 typ. to Curb ( -0 Min.) Sign Panel Pole/Breakaway 5 Foot Furnishing Zone NOTE: All locations shall be installed within the City ROW. If during the initial survey it is determined any part of the sign (pole or panel) extends outside of the City s Right of Way vertical plane and into private property, the installer must notify the city prior to fabrication/installation. NOTES CLIENT / OJECT Reference View: Example - 5 foot Furnishing Zone / City Right of Way SCALE: Not To Scale Note: Top View of VDIR.-3 shown as example. OJECT NO. Figure 7 Not to Scale SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Placement Guidelines B.5

19 C Menu of Sign Types

20 SPECIFICATIONS MENU OF SIGN TYPES Gateway Identification Identification Parks Identification WELCOME TO W Y O M I N G VISIT HISTORIC DOWNTOWN GATE. City Gateway Ground-Mounted PUBLIC WORKS 95 THIRD ST DEST. Identification Ground-Mounted CITY HALL 5 W. CEDAR ST DEST. Identification Ground-Mounted RAWLINS RECYCLING CENTER TUESDAY-FRIDAY - 8AM-5PM SATURDAY - 8AM-:30PM 54 E. DALEY STREET DEST.3 Identification Post-Mounted RAWLINS SINGS PARK Hours Open: 6 am - am No overnight camping DEST.4 Identification Ground-Mounted. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Rawlins Signage Overview C.

21 SPECIFICATIONS MENU OF SIGN TYPES Vehicular Directionals Back View Back View. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT VDIR. Vehicular Directional Post-Mounted VDIR. Vehicular Directional Post-Mounted VDIR.3 Vehicular Directional Post-Mounted VDIR.4 Vehicular Directional Post-Mounted VDIR.5 Vehicular Directional Post-Mounted VDIR.6 Vehicular Directional Post-Mounted These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Vehicular Signage Overview C.

22 SPECIFICATIONS MENU OF SIGN TYPES Parking Directionals Parking Identification RV RV/PUBLIC PARKING Location Name Street Name. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT PARK.A Parking Trailblazer Utility Pole Application Single-Sided PARK.B Parking Trailblazer Utility Pole Application Single -sided PARK. Parking Trailblazer Post-Mounted Single-Sided PARK.3 Parking Lot Identification Post-Mounted Double or Single-Sided These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Parking Signage Overview C.3

23 5TH 4TH 3TH 9TH HIGH ALDER BIRCH CHERRY JEFFERS CALIFORNIA STATE NEVADA DAVIS DONNEL LARSEN IDAHO LEE HEATH HUGUS KENDRICK SHERMAN ALCOVA MILLER DONNEL STATE RYAN CENTER BROOKS WASHINGTON RODEO WATER JEFFERSON ALPHA DELTA DALEY MADISON MONROE MILLER SIGMA HAYES HARSHMAN HWY 7 MURRAY MCMICKEN ELK I-80 RAMP TERRY TR WITHROW CENTER ASH KIRKCOLM GLASGOW LOCH NESS DUNDEE KOONTZ RYAN EDINBURGH ALTON BONANZA PIPER CESSNA MAHONEY RAILROAD MCILVAINE PETERSON CLOVERLEAF in =,500 ft Approximate Total Distance: 6.8 miles or kilometers Jack Ryan with companions believed to be Butch Cassidy, the Sundance Kid, & the Wild Bunch Baggs, WY, circa 896 Courtesy of Carbon County Museum RAINBOW TE-TON BUILDING 6 4th Street The Rainbow-Teton Building was built in 899 as an addition to the Brunswick Hotel located next door. The building soon became the home of Jack Ryan s Home Ranch Saloon where it is believed Ryan laundered money from Wild Bunch robberies. Several other saloons were housed here before the Rainbow Hotel opened on the upper floor, providing cheap rooms to saloon customers in the 940s. ISON RIOT Early images of the Wyoming Penitentiary show only a very small wall around the exterior. Over time, and after many jail breaks, prison wardens constructed the foot concrete wall that currently exists. On the north side of the Wyoming always had a home field advantage. The 9. A concrete structure replaced the Frontier Prison are the workshops and first prison baseball team performed Rochelle wooden, and remained in use recreation areas. In 9 Governor excellently until the execution of their until the prison closed in 98. At that Joseph M. Carey promoted prison catcher Joseph Seng in 9. time the building was torn down while reform and oversaw the construction removing the factory equipment. Also of recreational facilities. From this The prison was home to the prison in 9, a concrete wall replaced the time, the prison had its own baseball broom factory, license plate factory and original wooden barricade after several team. The team played local teams woolen mill. Originally made of wood, prisoners successfully escaped. from all over Wyoming and they the building burnt in a prison riot in BASEBALL Old Pen Baseball: The baseball team at the Wyoming Penitentiary, called the All Stars, played teams from across Wyoming. They always had the home field advantage. W WALNUT ST 3RD ST 5TH ST 6TH ST U.S. 30 BUSINESS W PINE ST Staff of the Wyoming State Penitentiary in the early 900s. Old Pen from the Rear: Facing south into the backyard of the prison you can see the baseball field and the space where the workshop building once stood. This postcard from the 90s shows where the early wooden workshop once stood. YOU ARE HERE CEDAR ST S FRONT ST W STATE ST W DAVIS ST U.S. 30 BUSINESS W FRONT ST U.S. 30 BUSINESS E CENTER ST WASHINGTON ST SPECIFICATIONS MENU OF SIGN TYPES Pedestrian Directional Pedestrian Kiosk 3-Sided Interpretive System City Hall Chamber of Commerce Library Courthouse Rodeo Park Public Restrooms Parking. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. SCARLET ABERDEEN DUNBLANE KILMARY CUTTY SARK Legend Walking_Path HAPPY HOLLOW ENERGY Tunnels COULSON 6TH PARK FAWN COULSON 4TH MOUNTAIN VIEW TH TH NIEMAN 0TH 8TH JEFFERS HWY 7 8TH 9TH 7TH BENNETT PERRY STRATTON 6TH FRONT PACIFIC PINE BUFFALO FRONT 3RD WALNUT MAPLE SUCE 5TH UP OVERPASS ARIZONA CEDAR 4TH GRANT MAHONEY ND ST WYOMING PERRINE UTAH COLORADO ILLINOIS ILLINOIS RAILROAD RITTER FRONT MADISON SAGE HILLS SANDRA HIGLEY APPLE HIGLEY INVERNESS OLIVE MACTAVISH ASH LOCUST JONES SEILOFF BEECHCRAFT PLAZA AIRPORT AIRPORT I-80 WEST WYDOT ROGER I-80 EAST ROCHELLE I-80 RAMP WOOLEN MILL LICENSE PLATE FACTORY WYOMING FRONTIER ISON BROOM FACTORY WOODEN BARRACADE JOSEPH SENG 9 900s 90s CLIENT / OJECT PDIR. Pedestrian Directional Post-Mounted KIOSK. 3-Sided Side View INTERP. Interpretive -Small Post-Mounted INTERP. Interpretive - Large -leg Stanchion These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Pedestrian Signage Overview C.4

24 KEY: S V8 9 D Design Intent Drawings Color Designator Specification Note The Color Designator Chart is found in the Graphic Standards section. The Specification Notation is found on the same page as the drawings.

25 SPECIFICATIONS SIGN TYPE: GATE. FUNCTION: City Gateway 5'-4" 4'-" 4'-" 0. GATEWAY SIGN CABINET MATERIAL: Aluminum extrusion and sheet FABRICATION OCESS: Extruded framing / Fabricated EDGES: Square, Smooth COLOR: Custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENERS: Hidden fasteners. Cabinet internal post(s) match-plate assembly to footer. NOTE: Cabinet is internally NON-illuminated but will require access panel on back side, for match-plate assembly. 4. GATEWAY - LETTERS / INCH MATERIAL: /" thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. 3'-4" P7 0 P7 0 P0 3 M4. STONE BASE MATERIAL: Quarry Buff + Pink/Buff (Quality Building Stone Inc.) FABRICATION OCESS: Quarry block mix (3 5/8, 7 5/8, 5/8), 4 inch depth, Ashler pattern. FASTENER: Mortar to CMU block utilizing metal straps. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. NOTE: Stone must extend below grade 3 to 6 inches. 3 Top View: GATE. SCALE: 3/8" = '-0". STONE CONCRETE CAP MATERIAL: Formed concrete caps, color. FABRICATION OCESS: Formed and poured colored concrete. CAP COLOR: Match Quarry Buff stone color. FASTENER: Mortar to Stone and CMU block. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. F. 3. GATEWAY - LETTERS INCH MATERIAL: " thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. 8'-6" 3'-4" P 4 '-0" '-0" NOTES WELCOME TO P7 0 P3 0 P7 0. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 7'-5" W Y O M I N G P7 0 P0 3 P5 0 P0 4 7'-5" '-0 /" P5 0 P3 0 CLIENT / OJECT OJECT NO. VISIT HISTORIC DOWNTOWN Front View: GATE. SCALE: 3/8" = '-0" M4 P 4 M3 '- /" Side View: GATE. SCALE: 3/8" = '-0" SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type GATE. City Gateway D.

26 SPECIFICATIONS SIGN TYPE: GATE. FUNCTION: City Gateway P0 3 P7 0 P7 0 M4 0. GATEWAY SIGN CABINET MATERIAL: Aluminum extrusion and sheet FABRICATION OCESS: Extruded framing / Fabricated EDGES: Square, Smooth COLOR: Custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENERS: Hidden fasteners. Cabinet internal post(s) match-plate assembly to footer. NOTE: Cabinet is internally NON-illuminated but will require access panel on back side, for match-plate assembly.. STONE BASE MATERIAL: Quarry Buff + Pink/Buff (Quality Building Stone Inc.) FABRICATION OCESS: Quarry block mix (3 5/8, 7 5/8, 5/8), 4 inch depth, Ashler pattern. FASTENER: Mortar to CMU block utilizing metal straps. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. NOTE: Stone must extend below grade 3 to 6 inches. 4. GATEWAY - LETTERS / INCH MATERIAL: /" thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. 3 Top View: GATE. SCALE: 3/8" = '-0". STONE CONCRETE CAP MATERIAL: Formed concrete caps, color. FABRICATION OCESS: Formed and poured colored concrete. CAP COLOR: Match Quarry Buff stone color. FASTENER: Mortar to Stone and CMU block. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. 3. GATEWAY - LETTERS INCH MATERIAL: " thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. F. 8'-6" 3'-4" '-0" '-0" 6 /4" P7 0 P3 0 P7 0 P5 0 NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT 7'-5" '-0 3/4" 7'-5" 5'-3 /" OJECT NO. M4 SUBCONSULTANT Back View: GATE. SCALE: 3/8" = '-0" M3 '- /" Side View: GATE. SCALE: 3/8" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type GATE. City Gateway D.

27 SPECIFICATIONS SIGN TYPE: VDIR. FUNCTION: Vehicular Directional F. '-6 /4" 6 3/4" 4" 9 /" 9 /" 4 4'-" 3'-0" Top View: VDIR. 4'-" 3'-0" 4 /" 4 /" P9 4 R3 5 P5 7 R 5 P9 P9 3 6" '-" 6" V3 6 V8 6 V7 6 V6 6 V8 6. 3x5 POST - RECTANGULAR MATERIAL: 3" x 5" x.50" wall Aluminum rectangle FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs.. SYNTHETIC WOOD PANEL - 5 /4 MATERIAL: " X 6" nominal, Highwood Synthetic Wood, or approved equal. FABRICATION OCESS: Extruded, solid, non-toxic synthetic wood EDGES: Front - "naturetex" (wood grain); Sides - Smooth finish. COLOR: Mohagony, stnd color (Appears as Dark Weathered Red Cedar) SURFACE OCESS: Natural FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. POST CUFF - Large MATERIAL: /4" thick Aluminum sheet FABRICATION OCESS: Fabricated, Stitch-welds, -piece construction COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 4. 3x5 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 5. SIGN PANEL - REFLECTIVE MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut PANEL EDGES OCESS: Paint all panel edges with Matthews Acrylic Polyurethane, with clear coat satin finish. COLOR: Custom, as noted GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 6. SIGN PANEL BACK - VINYL PATTERN MATERIAL: 3M ScotchCal Opaque White Vinyl SURFACE OCESS: Surface applied per according to 3M manufacturers specifications. GRAPHICS: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. 7. Uplift Sign Panel - Paint + VINYL MATERIAL: /8" thick Aluminum sheet FABRICATION OCESS: Router Cut, Brake-formed EDGES: Square, Smooth SURFACE OCESS OUTSIDE: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. SURFACE OCESS INSIDE: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs. M NOTES 7'-6" 9'-0". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT '-0" 7'-0" OJECT NO. SUBCONSULTANT Front View: VDIR. 50 Side View: VDIR. 3 Back View: VDIR. SCALE: " = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type VDIR. Vehicular Directional D.3

28 SPECIFICATIONS SIGN TYPE: VDIR. FUNCTION: Vehicular Directional F. 6 3/4" 4'-6 /" 4" 9 /" 9 /" 4 4'-" 3'-0" Top View: VDIR. 4'-" 3'-0" 4 /" 4 /" P9 4 R3 5 R5 5 R 5 P9 P9 3 '-4" 4'-" 6" 6" P5 7 V3 6 V8 6 V7 6 V6 6 V8 6. 3x5 POST - RECTANGULAR MATERIAL: 3" x 5" x.50" wall Aluminum rectangle FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs.. SYNTHETIC WOOD PANEL - 5 /4 MATERIAL: " X 6" nominal, Highwood Synthetic Wood, or approved equal. FABRICATION OCESS: Extruded, solid, non-toxic synthetic wood EDGES: Front - "naturetex" (wood grain); Sides - Smooth finish. COLOR: Mohagony, stnd color (Appears as Dark Weathered Red Cedar) SURFACE OCESS: Natural FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. POST CUFF - Large MATERIAL: /4" thick Aluminum sheet FABRICATION OCESS: Fabricated, Stitch-welds, -piece construction COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 4. 3x5 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 5. SIGN PANEL - REFLECTIVE MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut PANEL EDGES OCESS: Paint all panel edges with Matthews Acrylic Polyurethane, with clear coat satin finish. COLOR: Custom, as noted GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 6. SIGN PANEL BACK - VINYL PATTERN MATERIAL: 3M ScotchCal Opaque White Vinyl SURFACE OCESS: Surface applied per according to 3M manufacturers specifications. GRAPHICS: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. 7. Uplift Sign Panel - Paint + VINYL MATERIAL: /8" thick Aluminum sheet FABRICATION OCESS: Router Cut, Brake-formed EDGES: Square, Smooth SURFACE OCESS OUTSIDE: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. SURFACE OCESS INSIDE: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs. M NOTES 7'-6" '-0 /". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT '-0" 7'-0" OJECT NO. SUBCONSULTANT Front View: VDIR. 50 Side View: VDIR. 3 Back View: VDIR. SCALE: " = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type VDIR. Vehicular Directional D.4

29 4'-" SPECIFICATIONS SIGN TYPE: VDIR.3 FUNCTION: Vehicular Directional F. 6'-7" 6 3/4" 4" 9 /" 9 /" 4 3'-0" Top View: VDIR.3 4'-" 3'-0" 4 /" 4 /" P9 4 R3 5 R5 5 R 5 P9 P9 3 6'-" 6" 6" P5 7 3'-0 /4" V3 6 V8 6 V7 6 V6 6 V8 6. 3x5 POST - RECTANGULAR MATERIAL: 3" x 5" x.50" wall Aluminum rectangle FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs.. SYNTHETIC WOOD PANEL - 5 /4 MATERIAL: " X 6" nominal, Highwood Synthetic Wood, or approved equal. FABRICATION OCESS: Extruded, solid, non-toxic synthetic wood EDGES: Front - "naturetex" (wood grain); Sides - Smooth finish. COLOR: Mohagony, stnd color (Appears as Dark Weathered Red Cedar) SURFACE OCESS: Natural FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. POST CUFF - Large MATERIAL: /4" thick Aluminum sheet FABRICATION OCESS: Fabricated, Stitch-welds, -piece construction COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 4. 3x5 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 5. SIGN PANEL - REFLECTIVE MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut PANEL EDGES OCESS: Paint all panel edges with Matthews Acrylic Polyurethane, with clear coat satin finish. COLOR: Custom, as noted GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 6. SIGN PANEL BACK - VINYL PATTERN MATERIAL: 3M ScotchCal Opaque White Vinyl SURFACE OCESS: Surface applied per according to 3M manufacturers specifications. GRAPHICS: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. 7. Uplift Sign Panel - Paint + VINYL MATERIAL: /8" thick Aluminum sheet FABRICATION OCESS: Router Cut, Brake-formed EDGES: Square, Smooth SURFACE OCESS OUTSIDE: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. SURFACE OCESS INSIDE: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs. 7'-6" M 4'-4" NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT '-0" 7'-0" OJECT NO. SUBCONSULTANT Front View: VDIR.3 50 Side View: VDIR.3 3 Back View: VDIR.3 SCALE: " = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type VDIR.3 Vehicular Directional D.5

30 SPECIFICATIONS SIGN TYPE: VDIR.4 FUNCTION: Vehicular Directional F.3 '-9" 6 3/4" 3" '-6" 7'-4" 8 /" 6'-3" 4 /" 4 Top View: VDIR.4 7'-4" 8 /" 6'-3" 4 /" 6" '-" P9 9 R3 5 R 5 P5 7 V3 6 V8 6 V7 6 V6 6 V SIGN PANEL - REFLECTIVE MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut PANEL EDGES OCESS: Paint all panel edges with Matthews Acrylic Polyurethane, with clear coat satin finish. COLOR: Custom, as noted GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 6. SIGN PANEL BACK - VINYL PATTERN MATERIAL: 3M ScotchCal Opaque White Vinyl SURFACE OCESS: Surface applied per according to 3M manufacturers specifications. GRAPHICS: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/ Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. 7. Uplift Sign Panel - Paint + VINYL MATERIAL: /8" thick Aluminum sheet FABRICATION OCESS: Router Cut, Brakeformed EDGES: Square, Smooth SURFACE OCESS OUTSIDE: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. SURFACE OCESS INSIDE: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 8. 5x5 POST MATERIAL: 5" sq. x.50" wall Aluminum Square Tube FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe B55 breakaway support system, as per WYDOT breakaway specs. 9. 5x5 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs. NOTES 7'-0" P9 8 9'-9" 9'-3". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT '-0" OJECT NO. SUBCONSULTANT Front View: VDIR.4 50 Side View: VDIR.4 3 Back View: VDIR.4 These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type VDIR.4 Vehicular Directional D.6

31 SPECIFICATIONS SIGN TYPE: VDIR.5 FUNCTION: Vehicular Directional F.3 4'-9" 6 3/4" 3" 4'-6" 7'-4" 8 /" 6'-3" 4 /" 4 Top View: VDIR.5 7'-4" 8 /" 6'-3" 4 /" 6" 3'-" P9 9 R5 5 R 5 R3 5 3'-" P5 7 V3 6 V8 6 V7 6 V6 6 V SIGN PANEL - REFLECTIVE MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut PANEL EDGES OCESS: Paint all panel edges with Matthews Acrylic Polyurethane, with clear coat satin finish. COLOR: Custom, as noted GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 6. SIGN PANEL BACK - VINYL PATTERN MATERIAL: 3M ScotchCal Opaque White Vinyl SURFACE OCESS: Surface applied per according to 3M manufacturers specifications. GRAPHICS: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/ Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. 7. Uplift Sign Panel - Paint + VINYL MATERIAL: /8" thick Aluminum sheet FABRICATION OCESS: Router Cut, Brakeformed EDGES: Square, Smooth SURFACE OCESS OUTSIDE: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. SURFACE OCESS INSIDE: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 8. 5x5 POST MATERIAL: 5" sq. x.50" wall Aluminum Square Tube FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe B55 breakaway support system, as per WYDOT breakaway specs. 9. 5x5 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs. NOTES P9 8 '-9" '-3". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 7'-0" CLIENT / OJECT '-0" OJECT NO. SUBCONSULTANT Front View: VDIR.5 50 Side View: VDIR.5 3 Back View: VDIR.5 These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type VDIR.5 Vehicular Directional D.7

32 SPECIFICATIONS SIGN TYPE: VDIR.6 FUNCTION: Vehicular Directional F.3 6'-9" 6 3/4" 3" 6'-6" 7'-4" 8 /" 6'-3" 4 /" 4 Top View: VDIR.6 7'-4" 8 /" 6'-3" 4 /" 6" 5'-" P9 9 R 5 R5 5 R3 5 P5 7 V3 6 V8 6 V7 6 V6 6 V SIGN PANEL - REFLECTIVE MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut PANEL EDGES OCESS: Paint all panel edges with Matthews Acrylic Polyurethane, with clear coat satin finish. COLOR: Custom, as noted GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 6. SIGN PANEL BACK - VINYL PATTERN MATERIAL: 3M ScotchCal Opaque White Vinyl SURFACE OCESS: Surface applied per according to 3M manufacturers specifications. GRAPHICS: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/ Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. 7. Uplift Sign Panel - Paint + VINYL MATERIAL: /8" thick Aluminum sheet FABRICATION OCESS: Router Cut, Brakeformed EDGES: Square, Smooth SURFACE OCESS OUTSIDE: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. SURFACE OCESS INSIDE: 3M custom inks print direct to ScotchCal Opaque Vinyl with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 8. 5x5 POST MATERIAL: 5" sq. x.50" wall Aluminum Square Tube FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe B55 breakaway support system, as per WYDOT breakaway specs. 9. 5x5 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs. P9 8 3'-9" 3'-3" NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 7'-0" CLIENT / OJECT '-0" OJECT NO. SUBCONSULTANT Front View: VDIR.6 50 Side View: VDIR.6 3 Back View: VDIR.6 These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type VDIR.6 Vehicular Directional D.8

33 5 Top View: PARK.A SCALE: 3"='-0" Existing Light Pole P8 SPECIFICATIONS SIGN TYPE: PARK.A FUNCTION: Parking Trailblazer 0. /8" SIGN PANEL FRONT - REFLECTIVE MATERIAL: /8" thk Aluminum sheet FABRICATION OCESS: Router Cut COLOR: custom, as noted BACK AND SIDES OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. Tamper-resistant mechanically fastened to Bracket. '-9" '-6" 0 P8 P 0 '-9" '-6 /4" " '- 3/4" 4 3/4" 3" 8" 6 3/4" 5" '-6" Ø '-0" Ø 0 /4" R 0 R 0 R3 0 R6 0 R6 0 R 0 R3 0. POLE STRAP ATTACHMENT ODUCT: Band-It Band, or approved equal. MATERIAL: Type 0 SS SIZE: 3/4 inch FINISH: Stainless Steel FASTENER: Ultra-Lok Free End clamps NOTE: Sign Contractor to coordinate the removal or movement of interfering existing signs on utility poles, with the city.. Bracket MATERIAL: 3/6" thick Aluminum U-channel FABRICATION OCESS: Extruded EDGES: Square, Smooth COLOR: custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Tamper-resistant mechanically fastened to Sign Panel. SS strap-mounted to utility pole. NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT '-0" 7'-6" SUBCONSULTANT OJECT NO. Front View: PARK.A Side View: PARK.A 3 Back View: PARK.A 4 Graphic Layout: PARK.A SCALE: /" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type PARK.A Parking Trailblazer D.9

34 5 Top View: PARK.B SCALE: 3"='-0" Existing Light Pole P8 '-6" SPECIFICATIONS SIGN TYPE: PARK.B FUNCTION: Parking Trailblazer 0. /8" SIGN PANEL FRONT - REFLECTIVE MATERIAL: /8" thk Aluminum sheet FABRICATION OCESS: Router Cut COLOR: custom, as noted BACK AND SIDES OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. Tamper-resistant mechanically fastened to Bracket. 3'-5" '-6" RV 0 P8 P 0 3'-5" '- /4" " '- 3/4" 3 3/4" 6 /" /" " 6" 5 /4" 7 /" 7 /" RV R 0 Ø '-0" Ø 0 /4" R 0 R 0 R3 0 R6 0 R6 0 R 0 R3 0. POLE STRAP ATTACHMENT ODUCT: Band-It Band, or approved equal. MATERIAL: Type 0 SS SIZE: 3/4 inch FINISH: Stainless Steel FASTENER: Ultra-Lok Free End clamps NOTE: Sign Contractor to coordinate the removal or movement of interfering existing signs on utility poles, with the city.. Bracket MATERIAL: 3/6" thick Aluminum U-channel FABRICATION OCESS: Extruded EDGES: Square, Smooth COLOR: custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Tamper-resistant mechanically fastened to Sign Panel. SS strap-mounted to utility pole. NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT '-0" 7'-6" SUBCONSULTANT OJECT NO. Front View: PARK.B Side View: PARK.B 3 Back View: PARK.B 4 Graphic Layout: PARK.B SCALE: /" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type PARK.B Parking Trailblazer D.0

35 SPECIFICATIONS SIGN TYPE: PARK. FUNCTION: Parking Identification 0. /8" SIGN PANEL FRONT - REFLECTIVE MATERIAL: /8" thk Aluminum sheet FABRICATION OCESS: Router Cut COLOR: custom, as noted BACK AND SIDES OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. Tamper-resistant mechanically fastened to Post. '-4 /" 4 Top View: PARK. '-6" P9 4 0 P9 3 P 0 '-9" '-6 /4" " '- 3/4" 4 3/4" 3" 8" /" 3 /4" '-6" Ø '-0" Ø 0 /4" R 0 R 0 R3 0 R6 0 R6 0 R 0 R x4 POST - RECTANGULAR MATERIAL: " x 4" x.50" wall Aluminum rectangle FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe AS4 break-away support system, as per WYDOT break-away specs. 4. x4 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe AS4 break-away support system, as per WYDOT break-away specs. NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT '-0" 7'-6" SUBCONSULTANT OJECT NO. Front View: PARK. 50 Side View: PARK. 3 Back View: PARK. 4 Graphic Layout: PARK. SCALE: /" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type PARK. Parking I.D. D.

36 SPECIFICATIONS SIGN TYPE: PARK.3 FUNCTION: Parking Identification 4'-0" 9 /" 9 /" 4 4'-" 3'-0" RV/PUBLIC PARKING Top View: PARK.3 Double-Sided 4'-" 3'-0" 4 /" 4 /" P3 5 P9 4 R6 5 R3 5 R 5 R 5 5 Top View: PARK.3 Single-Sided P3 5 4'-4 /" RV/PUBLIC PARKING. 3x5 POST - RECTANGULAR MATERIAL: 3" x 5" x.50" wall Aluminum rectangle FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe B55 breakaway support system, as per WYDOT breakaway specs.. SYNTHETIC WOOD PANEL - 5 /4 MATERIAL: " X 6" nominal, Highwood Synthetic Wood, or approved equal. FABRICATION OCESS: Extruded, solid, nontoxic synthetic wood EDGES: Front - "naturetex" (wood grain); Sides - Smooth finish. COLOR: Mohagony, stnd color (Appears as Dark Weathered Red Cedar) SURFACE OCESS: Natural FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. POST CUFF - Large MATERIAL: /4" thick Aluminum sheet FABRICATION OCESS: Fabricated, Stitchwelds, -piece construction COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 4. 3x5 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 5. SIGN PANEL - REFLECTIVE + PAINT MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut PANEL BACK + EDGES OCESS: Paint all panel backs and edges with Matthews Acrylic Polyurethane, with clear coat satin finish. COLOR: Custom, as noted GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe B55 breakaway support system, as per WYDOT breakaway specs. F.4 Location Name Street Name R6 5 R7 5 Location Name Street Name P9 6" P9 3 6" 7'-6" M '-7 /" NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT '-0" 7'-0" OJECT NO. SUBCONSULTANT Front View: PARK.3 50 Side View: PARK.3 3 Back View: PARK.3 SCALE: " = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type PARK.3 Parking Identification D.

37 SPECIFICATIONS SIGN TYPE: DEST. FUNCTION: ID 0. SIGN CABINET MATERIAL: Aluminum extrusion and sheet FABRICATION OCESS: Extruded framing / Fabricated EDGES: Square, Smooth COLOR: Custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENERS: Hidden fasteners. Cabinet internal post(s) match-plate assembly to footer. 5. LETTERS /4 INCH MATERIAL: /4" thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. 9'-6" 9'- /" 9'-4 /4" 8'- /". STONE BASE MATERIAL: Quarry Buff + Pink/Buff (Quality Building Stone Inc.) FABRICATION OCESS: Quarry block mix (3 5/8, 7 5/8, 5/8), 4 inch depth, Ashler pattern. FASTENER: Mortar to CMU block utilizing metal straps. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. NOTE: Stone must extend below grade 3 to 6 inches. '-9" '-6 /". STONE CONCRETE CAP MATERIAL: Formed concrete caps, color. FABRICATION OCESS: Formed and poured colored concrete. CAP COLOR: Match Quarry Buff stone color. FASTENER: Mortar to Stone and CMU block. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. 4 Top View: DEST. SCALE: 3/8" = '-0" 5 Back View: DEST. SCALE: 3/8" = '-0" 4. LETTERS / INCH MATERIAL: /" thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. F.6 9'-6" '-" 8'- /" M4 P 4 '-8" '- /" '-9" '-9 /" '-6 /" NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 6'-0" 5'-" 8" PUBLIC WORKS 95 THIRD ST P7 0 P3 0 M5 3 P7 0 P 0 SUBCONSULTANT CLIENT / OJECT OJECT NO. Front View: DEST. SCALE: 3/8" = '-0" M3 Side View: DEST. SCALE: 3/8" = '-0" 3 Side View: DEST. SCALE: 3/8" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type DEST. Identification D.3

38 SPECIFICATIONS SIGN TYPE: DEST. FUNCTION: ID 4'-5" 4'-9" 0. SIGN CABINET MATERIAL: Aluminum extrusion and sheet FABRICATION OCESS: Extruded framing / Fabricated EDGES: Square, Smooth COLOR: Custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENERS: Hidden fasteners. Cabinet internal post(s) match-plate assembly to footer. 5. LETTERS /4 INCH MATERIAL: /4" thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. '-7" '-0" 4'-6" '-6". STONE BASE MATERIAL: Quarry Buff + Pink/Buff (Quality Building Stone Inc.) FABRICATION OCESS: Quarry block mix (3 5/8, 7 5/8, 5/8), 4 inch depth, Ashler pattern. FASTENER: Mortar to CMU block utilizing metal straps. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. NOTE: Stone must extend below grade 3 to 6 inches. 4 Top View: DEST.. STONE CONCRETE CAP MATERIAL: Formed concrete caps, color. FABRICATION OCESS: Formed and poured colored concrete. CAP COLOR: Match Quarry Buff stone color. FASTENER: Mortar to Stone and CMU block. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. 5'-6" 4'-6" F.6 '-0 /" '-7" 5 Back View: DEST. 4. LETTERS / INCH MATERIAL: /" thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. M4 P 4 7'-5" 6'-5" 7" CITY HALL 5 W. CEDAR ST P7 0 P3 0 M5 3 P7 0 NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT OJECT NO. P 0 SUBCONSULTANT '-0" Front View: DEST. M3 Side View: DEST. 3 Side View: DEST. SCALE: " = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type DEST. Identification D.4

39 SPECIFICATIONS SIGN TYPE: DEST.3 FUNCTION: ID 7'-4" 8 /" 6'-3" 4 /" 5. SIGN PANEL - REFLECTIVE MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut PANEL EDGES OCESS: Paint all panel edges with Matthews Acrylic Polyurethane, with clear coat satin finish. COLOR: Custom, as noted GRAPHIC BACKGROUND AND COPY OCESS: 3M custom inks print direct to 3930 with 3M approved UV/Graffiti Vinyl Over-laminate. (See Color Sheet for all color and material specifications) FASTENER: Press-roll per 3M requirements. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe B55 breakaway support system, as per WYDOT breakaway specs. 4 Top View: DEST.3 SIGN PANEL - LOWER SECTION Hours and Address panel to be seperate removeable panel. Material /8" thk Aluminum. F.3 4'-9" 3" 4'-6" 8 /" C 6'-3" L 4 /" CITY OF RAWLINS RECYCLING CENTER TUESDAY-FRIDAY - 8AM-5PM SATURDAY - 8AM-:30PM 54 E. DALEY STREET 3'-" P9 9 R 5 R3 5 R7 5 R9 5 R x5 POST MATERIAL: 5" sq. x.50" wall Aluminum Square Tube FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe B55 breakaway support system, as per WYDOT breakaway specs. 9. 5x5 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 7'-0" P9 8 '-9" '-3" NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. '-0" SUBCONSULTANT CLIENT / OJECT OJECT NO. Front View: DEST.3 50 Side View: DEST.3 3 Back View: DEST.3 These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type DEST.3 Identification D.5

40 SPECIFICATIONS SIGN TYPE: DEST.4 FUNCTION: ID '-6" '-3" 6 /" '-9" '-8 /" '-6" 0. SIGN CABINET MATERIAL: Aluminum extrusion and sheet FABRICATION OCESS: Extruded framing / Fabricated EDGES: Square, Smooth COLOR: Custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. ICONS + INFO TEXT: 3M Scotchcal ElectroCut opaque vinyl film. FASTENERS: Hidden fasteners. Cabinet internal post(s) match-plate assembly to footer. 5. LETTERS /4 INCH MATERIAL: /4" thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. 4 Top View: DEST.4 3'-7" F.7 6" P7 0 '-7" '-3" 6 /". STONE BASE MATERIAL: Quarry Buff + Pink/Buff (Quality Building Stone Inc.) FABRICATION OCESS: Quarry block mix (3 5/8, 7 5/8, 5/8), 4 inch depth, Ashler pattern. FASTENER: Mortar to CMU block utilizing metal straps. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. NOTE: Stone must extend below grade 3 to 6 inches.. STONE CONCRETE CAP MATERIAL: Formed concrete caps, color. FABRICATION OCESS: Formed and poured colored concrete. CAP COLOR: Match Quarry Buff stone color. FASTENER: Mortar to Stone and CMU block. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. '-0" '-3 3/4" WASHINGTON PARK Hours Open: 6 am - am No overnight camping P4 0 V9 0 M5 3 V9 0 P7 0 WASHINGTON PARK Hours Open: 6 am - am No overnight camping 4. LETTERS / INCH MATERIAL: /" thick acrylic sheet FABRICATION OCESS: Routered. EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: Pin-mount flush to cabinet surface. NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT OJECT NO. '-0" min M4 SUBCONSULTANT 4" Front View: DEST.4 P 4 M3 '-" Side View: DEST.4 3 Back View: DEST.4 SCALE: " = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type DEST.4 Identification D.6

41 SPECIFICATIONS SIGN TYPE: PDIR. FUNCTION: Pedestrian Directional F.5 6 /4" '-4" 4 5" '-4 /" City Hall Chamber of Commerce Library Courthouse Public Restrooms Parking '- /" Top View: PDIR. SCALE:/" = '-0" 5" '-4 /" '- /" Rodeo Park 6 P9 5" '-" 6" P3 7 P0 7 City Hall Chamber of Commerce Library Courthouse Rodeo Park Public Restrooms Parking. 3x5 POST - RECTANGULAR MATERIAL: 3" x 5" x.50" wall Aluminum rectangle FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe B55 breakaway support system, as per WYDOT breakaway specs.. SYNTHETIC WOOD PANEL - 5 /4 MATERIAL: " X 6" nominal, Highwood Synthetic Wood, or approved equal. FABRICATION OCESS: Extruded, solid, nontoxic synthetic wood EDGES: Front - "naturetex" (wood grain); Sides - Smooth finish. COLOR: Mohagony, stnd color (Appears as Dark Weathered Red Cedar) SURFACE OCESS: Natural FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. POST CUFF - Large MATERIAL: /4" thick Aluminum sheet FABRICATION OCESS: Fabricated, Stitchwelds, -piece construction COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 4. 3x5 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 6. SIGN PANEL - PAINT & VINYL MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut COLOR: custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. GRAPHICS (s, Symbols, Arrows): 3M Scotchcal ElectroCut Opaque Vinyl Film. FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 7. Uplift Sign Panel - Paint ONLY MATERIAL: /8" thick Aluminum sheet FABRICATION OCESS: Router Cut, Brakeformed EDGES: Square, Smooth SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe B55 break-away support system, as per WYDOT break-away specs. P9 3 6" M NOTES 0'-0". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 7'-6" 7'-0" CLIENT / OJECT '-0" OJECT NO. SUBCONSULTANT Front View: PDIR. 50 Side View: PDIR. 3 Back View: PDIR. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type PDIR. Pedestrian Directional D.7

42 5TH 4TH CHERRY 3TH BIRCH 9TH HIGH ALDER JEFFERS CALIFORNIA STATE NEVADA DAVIS DONNEL LARSEN IDAHO LEE HEATH HUGUS KENDRICK SHERMAN ALCOVA MILLER DONNEL STATE RYAN CENTER BROOKS WASHINGTON RODEO WATER JEFFERSON ALPHA DALEY MADISON DELTA MONROE MILLER SIGMA HAYES HARSHMAN HWY 7 MURRAY MCMICKEN ELK I-80 RAMP TERRY TR WITHROW CENTER KIRKCOLM GLASGOW LOCH NESS KOONTZ ASH DUNDEE RYAN EDINBURGH ALTON BONANZA PIPER CESSNA MAHONEY RAILROAD MCILVAINE PETERSON CLOVERLEAF in =,500 ft Approximate Total Distance: 6.8 miles or kilometers SPECIFICATIONS SIGN TYPE: KIOSK. FUNCTION: Pedestrian Kiosk F.8 6'-4" '-8" 7" 3'-0" 3" 6" 3'-0" 4" 3 COULSON 6TH PARK FAWN COULSON 4TH MOUNTAIN VIEW TH TH NIEMAN 0TH 8TH JEFFERS HWY 7 9TH 8TH BENNETT STRATTON 7TH PERRY 6TH FRONT PACIFIC MAPLE PINE BUFFALO FRONT 5TH UP OVERPASS '-8" ARIZONA 3'-0" Top View: KIOSK. '-6" '-3" '-0" 3RD WALNUT SUCE CEDAR 4TH GRANT MAHONEY ND ST WYOMING PERRINE COLORADO UTAH ILLINOIS SCARLET HAPPY HOLLOW ILLINOIS RAILROAD RITTER FRONT MADISON SAGE HILLS SANDRA ABERDEEN HIGLEY APPLE DUNBLANE ENERGY HIGLEY KILMARY CUTTY SARK INVERNESS OLIVE MACTAVISH ASH LOCUST JONES SEILOFF BEECHCRAFT PLAZA AIRPORT AIRPORT I-80 WEST Front View: KIOSK. Legend WYDOT ROGER I-80 EAST P9 4 M4 Walking_Path Tunnels ROCHELLE P9 4 M 39 I-80 RAMP M6 36 P9 40 M4 M3 Side View: KIOSK. 3'-0" 4" 3'-0" 6" 4 '-3" '-0" /4" '-9 /" C /4" L /4" '-9 /" /4" ARTWORK TBD Panel Detail: KIOSK.. STONE BASE MATERIAL: Quarry Buff + Pink/Buff (Quality Building Stone Inc.) FABRICATION OCESS: Quarry block mix (3 5/8, 7 5/8, 5/8), 4 inch depth, Ashler pattern. FASTENER: Mortar to CMU block utilizing metal straps. Grout seams. GROUT COLOR: Pink grout, Beaded appearance.. STONE CONCRETE CAP MATERIAL: Formed concrete caps, color. FABRICATION OCESS: Formed and poured colored concrete. CAP COLOR: Match Quarry Buff stone color. FASTENER: Mortar to Stone and CMU block. Grout seams. GROUT COLOR: Pink grout, Beaded appearance. 36. MAP ARTWORK Panel ODUCT NAME: Phenolic Resin panel by izone or Fossil Industries. ODUCT: Digital high pressure laminate (dhpl) WARRANTY PERIOD: Ten (0) years from product ship date. MATERIAL THICKNESS: /4" thick FINISH: Matte or Satin (NO pebble or ice finish). FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). Note the locknuts are stitch-welded to kiosk internal panel. 39. CEDAR PANELS MATERIAL: " X 6" nominal, Western Red Cedar, rough cut, natural. FABRICATION OCESS: Rough cut EDGES: Ease or sand round all edges COLOR: Natural FASTENER: "Black"-colored tamper-resistant hardware (3/8" Heavy Hex Bolt, Flatwashers and SS Locknut). NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. 40. KIOSK INTERNAL PANEL MATERIAL: /4" thick Aluminum sheet FABRICATION OCESS: Fabricated COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: "Black"-colored tamper-resistant hardware 4. KIOSK TOP MATERIAL: Aluminum extrusion and sheet FABRICATION OCESS: Extruded framing / Fabricated EDGES: Square, Smooth COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENERS: Hidden fasteners CLIENT / OJECT OJECT NO. Sign Type KIOSK. Pedestrian Kiosk D.8

43 Jack Ryan with companions believed to be Butch Cassidy, the Sundance Kid, & the Wild Bunch Baggs, WY, circa 896 Courtesy of Carbon County Museum RAINBOW TE-TON BUILDING 6 4th Street The Rainbow-Teton Building was built in 899 as an addition to the Brunswick Hotel located next door. The building soon became the home of Jack Ryan s Home Ranch Saloon where it is believed Ryan laundered money from Wild Bunch robberies. Several other saloons were housed here before the Rainbow Hotel opened on the upper floor, providing cheap rooms to saloon customers in the 940s. '-3" 8" 4" /4" /4" 3" " 3" C " L " " P8 30 P8 30 /" 3 '-0" /" /8" 6 3/4" Eq. Eq. P8 30 '-/" Jack Ryan with companions believed to be Butch Cassidy, the Sundance Kid, & the Wild Bunch Baggs, WY, circa 896 Courtesy of Carbon County Museum RAINBOW TE-TON BUILDING 6 4th Street 6 /" The Rainbow-Teton Building was built in 899 as an addition to the Brunswick Hotel located next door. The building soon became the home of Jack Ryan s Home Ranch Saloon where it is believed Ryan laundered money from Wild Bunch robberies. Several other saloons were housed here before the Rainbow Hotel opened on the upper floor, providing cheap rooms to saloon customers in the 940s. 3 P3 3 P8 3 C Equal L Equal " 3/4" 7/8" 5/8" Rainbow Teton Bldg. P3 3 P8 3 P0 3 SPECIFICATIONS SIGN TYPE: INTERP. FUNCTION: Pedestrian Interpretive 3. x4 POST - RECTANGULAR MATERIAL: " x 4" x.50" wall Aluminum rectangle FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe AS4 break-away support system, as per WYDOT break-away specs. 4. x4 POST CAP MATERIAL: Cast Aluminum or /4" thick Aluminum Sheet FABRICATION OCESS: Cast or Fabricated COLOR: Custom, as noted. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Mechanically fastened to pole with hidden screws. 30. Interp SIgn Frame - Small MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut. Top frame must have router cut inset for graphic panel. EDGES: Square COLOR: Custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: "Black"-colored tamper-resistant hardware (3/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. Interp SIgn Frame - t-panel MATERIAL: /4" thk Aluminum Tee Extrusion FABRICATION OCESS: Mechanically cut EDGES: Square COLOR: Custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. TITLE: Interpretive panel Title screen-prints both sides of blade. FASTENER: "Black"-colored tamper-resistant hardware (3/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. Interp ARTWORK Panel - SMALL ODUCT NAME: Phenolic Resin panel by izone or Fossil Industries. ODUCT: Digital high pressure laminate (dhpl) WARRANTY PERIOD: Ten (0) years from product ship date. MATERIAL THICKNESS: /8" thick FINISH: Matte or Satin (NO pebble or ice finish). FASTENER: Fits into frame assembly. May add 3M double-stick thin tape to back of panel. 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe AS4 break-away support system, as per WYDOT break-away specs. 5 Section Detail SCALE: 3" = '-0" 6 Panel Detail SCALE: 3" = '-0" 7 Artwork Detail SCALE: 3" = '-0" 8 T Panel Detail SCALE: 3" = '-0" 9 Blade Detail SCALE: 3" = '-0" '-3" 8" P9 4 P " '-3" Rainbow Teton Bldg. P9 4 P8 30 P NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT P9 3 5'-7" P9 3 4 Top View: INTERP. SCALE: /" = '-0" OJECT NO. SUBCONSULTANT '-0" Front View: INTERP. Side View: INTERP Back View: INTERP. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type INTERP. Pedestrian Interpretive D.9

44 Jack Ryan with companions believed to be Butch Cassidy, the Sundance Kid, & the Wild Bunch Baggs, WY, circa 896 Courtesy of Carbon County Museum RAINBOW TE-TON BUILDING 6 4th Street The Rainbow-Teton Building was built in 899 as an addition to the Brunswick Hotel located next door. The building soon became the home of Jack Ryan s Home Ranch Saloon where it is believed Ryan laundered money from Wild Bunch robberies. Several other saloons were housed here before the Rainbow Hotel opened on the upper floor, providing cheap rooms to saloon customers in the 940s. Jack Ryan with companions believed to be Butch Cassidy, the Sundance Kid, & the Wild Bunch Baggs, WY, circa 896 Courtesy of Carbon County Museum RAINBOW TE-TON BUILDING 6 4th Street The Rainbow-Teton Building was built in 899 as an addition to the Brunswick Hotel located next door. The building soon became the home of Jack Ryan s Home Ranch Saloon where it is believed Ryan laundered money from Wild Bunch robberies. Several other saloons were housed here before the Rainbow Hotel opened on the upper floor, providing cheap rooms to saloon customers in the 940s. City Hall Chamber of Commerce Library Courthouse Rodeo Park Public Restrooms Parking SPECIFICATIONS SIGN TYPE: INTERP. FUNCTION: Pedestrian Interpretive 30. Interp SIgn Frame - Small MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router Cut. Top frame must have router cut inset for graphic panel. EDGES: Square COLOR: Custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. FASTENER: "Black"-colored tamper-resistant hardware (3/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. Interp SIgn Frame - t-panel MATERIAL: /4" thk Aluminum Tee Extrusion FABRICATION OCESS: Mechanically cut EDGES: Square COLOR: Custom, as noted SURFACE OCESS: Paint all exposed surfaces with Matthews Acrylic Polyurethane, with clear coat satin finish. TITLE: Interpretive panel Title screen-prints both sides of blade. FASTENER: "Black"-colored tamper-resistant hardware (3/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. Interp ARTWORK Panel - SMALL ODUCT NAME: Phenolic Resin panel by izone or Fossil Industries. ODUCT: Digital high pressure laminate (dhpl) WARRANTY PERIOD: Ten (0) years from product ship date. MATERIAL THICKNESS: /8" thick FINISH: Matte or Satin (NO pebble or ice finish). FASTENER: Fits into frame assembly. May add 3M double-stick thin tape to back of panel. 50. BREAKAWAY FOOTER FOOTER: Transpo Break-Safe AS4 break-away support system, as per WYDOT break-away specs. '-0" 4'-0" '-3" 8" Front View Detail Application: Pedestrian Directional 8" P8 30 P P8 30 P '-3" Rainbow Teton Bldg. Side View '-0" 4'-0" '-3" Detail Application: Vehicular Directional 5'-3" Front View Rainbow Teton Bldg. Side View NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Sign Type INTERP. Pedestrian Interpretive D.0

45 ISON RIOT Early images of the Wyoming Penitentiary show only a very small wall around the exterior. Over time, and after many jail breaks, prison wardens constructed the foot concrete wall that currently exists. On the north side of the Wyoming always had a home field advantage. The 9. A concrete structure replaced the Frontier Prison are the workshops and first prison baseball team performed Rochelle wooden, and remained in use recreation areas. In 9 Governor excellently until the execution of their until the prison closed in 98. At that Joseph M. Carey promoted prison catcher Joseph Seng in 9. time the building was torn down while reform and oversaw the construction removing the factory equipment. Also of recreational facilities. From this The prison was home to the prison in 9, a concrete wall replaced the time, the prison had its own baseball broom factory, license plate factory and original wooden barricade after several team. The team played local teams woolen mill. Originally made of wood, prisoners successfully escaped. from all over Wyoming and they the building burnt in a prison riot in W WALNUT ST U.S. 30 BUSINESS W PINE ST Staff of the Wyoming State Penitentiary in the early 900s. BASEBALL Old Pen Baseball: The baseball team at the Wyoming Penitentiary, called the All Stars, played teams from across Wyoming. They always had the home field advantage. Old Pen from the Rear: Facing south into the backyard of the prison you can see the baseball field and the space where the workshop building once stood. This postcard from the 90s shows where the early wooden workshop once stood. YOU ARE HERE 3RD ST 5TH ST 6TH ST CEDAR ST S FRONT ST W STATE ST W DAVIS ST U.S. 30 BUSINESS W FRONT ST U.S. 30 BUSINESS E CENTER ST WASHINGTON ST LICENSE PLATE FACTORY Early images of the Wyoming Penitentiary show only a very small wall around the exterior. Over time, and after many jail breaks, prison wardens constructed the foot concrete wall that currently exists. On the north side of the Wyoming always had a home field advantage. The 9. A concrete structure replaced the Frontier Prison are the workshops and first prison baseball team performed Rochelle wooden, and remained in use recreation areas. In 9 Governor excellently until the execution of their until the prison closed in 98. At that Joseph M. Carey promoted prison catcher Joseph Seng in 9. time the building was torn down while reform and oversaw the construction removing the factory equipment. Also of recreational facilities. From this The prison was home to the prison in 9, a concrete wall replaced the time, the prison had its own baseball broom factory, license plate factory and original wooden barricade after several team. The team played local teams woolen mill. Originally made of wood, prisoners successfully escaped. from all over Wyoming and they the building burnt in a prison riot in YOU ARE HERE W WALNUT ST 3RD ST 5TH ST 6TH ST U.S. 30 BUSINESS W PINE ST Staff of the Wyoming State Penitentiary in the early 900s. Old Pen Baseball: The baseball team at the Wyoming Penitentiary, called the All Stars, played teams from across Wyoming. They always had the home field advantage. Old Pen from the Rear: Facing south into the backyard of the prison you can see the baseball field and the space where the workshop building once stood. This postcard from the 90s shows where the early wooden workshop once stood. CEDAR ST S FRONT ST W STATE ST W DAVIS ST W FRONT ST U.S. 30 BUSINESS E CENTER ST WASHINGTON ST SPECIFICATIONS SIGN TYPE: INTERP. FUNCTION: Pedestrian Interpretive '-3" Outside Frame '-0" Inside Frame 4 3'-4" Outside Frame 3'-0" Inside Frame Frame Detail: INTERP. P9 33 '-" Interpretive Panel 5 ISON RIOT 3'-" Interpretive Panel WOODEN BARRACADE BASEBALL WOOLEN MILL WYOMING FRONTIER ISON BROOM FACTORY Interpretive Panel SIZE JOSEPH SENG 9 900s 90s U.S. 30 BUSINESS 35 5" '-3" Outside Frame '-5" Backplate 5" 6 3" 3'-4" '-0" Backplate Frame Back Detail: INTERP. 3" P9 33. SYNTHETIC WOOD PANEL - 5 /4 MATERIAL: " X 6" nominal, Highwood Synthetic Wood, or approved equal. FABRICATION OCESS: Extruded, solid, nontoxic synthetic wood EDGES: Front - "naturetex" (wood grain); Sides - Smooth finish. COLOR: Mohagony, stnd color (Appears as Dark Weathered Red Cedar) SURFACE OCESS: Natural FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3. x4 POST - RECTANGULAR MATERIAL: " x 4" x.50" wall Aluminum rectangle FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FOOTER: Transpo Break-Safe AS4 break-away support system, as per WYDOT break-away specs. 33. Interp SIgn Frame - LARGE FRAME MATERIAL: 3/8" thk Aluminum sheet FABRICATION OCESS: Router Cut. Top frame must have router cut inset for graphic panel. EDGES: Square COLOR: Custom, as noted BACKER PLATE MATERIAL: /4" thk Aluminum sheet FABRICATION OCESS: Router cut. Posts and braces must go thru backer plate. Posts and braces stitch-weld to backer plate. SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: All mechanical fasteners must be tamper-resistant. Note back elevation drawing for recommended fastener applications. 34. Interp Sign - LARGE BraCES MATERIAL: " x 4" x.50" wall Aluminum rectangle FABRICATION OCESS: Extruded COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: Stitch-weld. 35. Interp ARTWORK Panel - LARGE ODUCT: Porcelain Enamel Graphics, on /8" thick steel panel. OCESS: Full-color, or 6-spot color maximum. FINISHED THICKNESS: ±3/6" thick FINISH: Satin WARRANTY PERIOD: 5 years from product ship date. FASTENER: Fits into frame assembly. May add 3M double-stick thin tape to back of panel. 37. POST CUFF - Small MATERIAL: /4" thick Aluminum sheet FABRICATION OCESS: Fabricated, Stitchwelds, -piece construction COLOR: Custom, as noted SURFACE OCESS: Coat all exposed surfaces with TIGER Drylac Series 38 Powdercoating, two-coat process finish. FASTENER: "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut). 3'-4" 3'-4" 3'-" 7 /4" minimum '-0" from trail edge '- /" WOOLEN MILL LICENSE PLATE FACTORY WYOMING FRONTIER ISON BROOM FACTORY WOODEN BARRACADE JOSEPH SENG 9 900s 90s 7 /4" P P9 37 P9 34 '-5" 5" ±'-" ±7 /" 5 P9 34 P9 37 P9 3 ±3'-3 /" '- /" ±'-" '-0" Backplate P9 33 NOTES. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT OJECT NO. Front View: INTERP. Side View: INTERP. 3 Back View: INTERP. SUBCONSULTANT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. Sign Type INTERP. Pedestrian Interpretive D.

46 E Graphic Layouts

47 SPECIFICATIONS SIGN PANEL LAYOUTS: VDIR. 3 4'-" 3'-9" 7" 7" s shown are NOT actual messages. Provided for illustrative purposes only. Refer to message schedule for actual sign messages. 8" Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. Graphic Layout: VDIR. SCALE: 3/4" = '-0" 6'-7" 6'-" 8" 3" 4" " 4" 4'-0 /" 3 /" " 5" 4" " 4" 8" 3 /" 3 /" 5" " 6" 4" " 4" 3 /" '-6 /" 4'-" 3'-9" 7" 7" 4'-" 3'-9" 7" 7" 4'-6 /" '-0 /" 5" /4". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. VDIR.-3 Layout Drawings Graphic Layout: VDIR. SCALE: 3/4" = '-0" 3 Graphic Layout: VDIR.3 SCALE: 3/4" = '-0" E.

48 SPECIFICATIONS SIGN PANEL LAYOUTS: VDIR.4-6 s shown are NOT actual messages. Provided for illustrative purposes only. Refer to message schedule for actual sign messages. Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. 7'-5" 7'-0" 7" " 7" '-6" " " 6" 9" 4 /" Graphic Layout: VDIR.4 7'-5" 7'-0" 7" " 7" 4'-6" " " " " 7" " 7'-5" 7'-0" 6" 9" Graphic Layout: VDIR.5 4 /" 9" 6" 4 /" 7" 7 /" 6'-6" " " " " /" /" " " 3 Graphic Layout: VDIR.6 7 /" /". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. VDIR.4-6 Layout Drawings E.

49 SPECIFICATIONS SIGN PANEL LAYOUTS: PARK.3 s shown are NOT actual messages. Provided for illustrative purposes only. Refer to message schedule for actual sign messages. Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. 4'-" 4'-" 3'-9" 3'-9" 7" Ø '-4" 7" Ø '-4" Ø '- 3/4" Ø '- 3/4" 4'-0" 4'-4" '-" 3" " 3" 3" 3" " 3" 6" " 6" 3/4" PUBLIC PARKING Location Name Street Name Graphic Layout: PARK.3 SCALE: " = '-0" 4'-0" 4'-4" '-" 3 /4" 7 /" 5 /" 3 /" 3" " 3" " 3" 3" RV/PUBLIC PARKING Location Name Street Name. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. PARK.3 Layout Drawings E.3

50 SPECIFICATIONS SIGN PANEL LAYOUTS: DEST. s shown are NOT actual messages. Provided for illustrative purposes only. Refer to message schedule for actual sign messages. '-3 3/4" '-0 /" 8 /4" 3 /" Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. 3" 6" 4" 0" 3 /" PUBLIC WORKS 6'-3 /4" '-" 0" /" 3" 95 THIRD ST Graphic Layout: DEST. '-3 3/4" '-0 /" 8 /4" 3 /" 3" 6". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 6'-3 /4" '-" 0" 4" 5 3/4" 3" 0" /" POLICE DEPARTMENT COMPLEX 3" 5 FIFTH ST Graphic Layout: DEST. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. DEST. Layout Drawings E.4

51 SPECIFICATIONS SIGN PANEL LAYOUTS: DEST. s shown are NOT actual messages. Provided for illustrative purposes only. Refer to message schedule for actual sign messages. Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. 9 /4" 4'-6" 4 3/4" /" 9 /4" 4'-6" 4 3/4" /" " 4" " 4" 6'-5" 3" 7" /" CITY HALL 6'-5" '-3" 6" 3" 6" 3"3" 3" No. FIRE STATION '-" 7" " " 5 W. CEDAR ST '-" 7" " " ADDRESS HERE ANIMAL SHELTER ADDRESS HERE No. FIRE STATION ADDRESS HERE. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT Graphic Layouts: DEST. Graphic Layouts: DEST. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. DEST. Layout Drawings E.5

52 SPECIFICATIONS SIGN PANEL LAYOUTS: DEST.3 s shown are NOT actual messages. Provided for illustrative purposes only. '-0 /" 7'-0" '-0 /" 7'-0" Refer to message schedule for actual sign messages. Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. 4'-6" 4'-6" '-5 /" 3'-0 /" '-5 /" 3'-0 /" /" /" " " " /" 3" 6 " 3" 3" '-" /4" /" " " 3" 6 " 3" 3" '-" /" /4" /" 0" '-0 /" 0" CITY OF RAWLINS LANDFILL DIVISION MONDAY-SATURDAY - 8AM-5PM 0 E. GUN CLUB ROAD 7'-0" CITY OF RAWLINS RECYCLING CENTER TUESDAY-FRIDAY - 8AM-5PM SATURDAY - 8AM-:30PM 54 E. DALEY STREET Graphic Layout: DEST.3 /4" 4'-6" '-5 /" 3'-0 /" 4'-6" 0" 6" 3" 6" " 3/4" 3/4" " /4" /" " " /" '-5 /" 3'-0 /" '-" 3" 3" 6 " 3" " /4" /" 0" '-0 /" 0" OUTDOOR SHOOTING COMPLEX OPEN MAY ST TO OCTOBER 3ST Tuesday-Friday PM-Dusk Saturday - 9 AM-Dusk Sunday - PM-Dusk Monday - Closed 0 E. GUN CLUB ROAD 7'-0" CITY OF RAWLINS PARKS DIVISION 600 E. DALEY STREET. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. DEST.3 Layout Drawings E.6

53 SPECIFICATIONS '-8" '-8" SIGN PANEL LAYOUTS: DEST.4 /" /4" 6" 3" 6" 6" 6" 6 3/4" 7 /4" s shown are NOT actual messages. Provided for illustrative purposes only. Refer to message schedule for actual sign messages. Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. /4" 3/4" 3/4" 3 /" '-0" 6" /" '- /" 4 /" 3" " 3" 3" RAWLINS SINGS PARK Hours Open: 6 am - am No overnight camping KEY CLUB PARK Hours Open: 6 am - am No overnight camping TULLY PARK Hours Open: 6 am - am No overnight camping WASHINGTON PARK Hours Open: 6 am - am No overnight camping DEPOT PARK Hours Open: 6 am - am No overnight camping BOLTEN PARK Hours Open: 6 am - am No overnight camping ROB ROY PARK Hours Open: 6 am - am No overnight camping VFW PARK Hours Open: 6 am - am No overnight camping SPORTS COMPLEX Hours Open: 6 am - am No overnight camping Hours of operation and Amenities icon list TBD and provided by Client.. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. DEST.4 Layout Drawings Graphic Layouts: DEST.4 SCALE: 3/4" = '-0" Graphic Layouts: DEST.4 SCALE: 3/4" = '-0" Alternate Layouts E.7

54 SPECIFICATIONS SIGN PANEL LAYOUTS: PDIR. s shown are NOT actual messages. Provided for illustrative purposes only. Refer to message schedule for actual sign messages. Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. '-4 /" '-4 /" '-3" '-3" 6 /4" /" " 3 /" 3 /" " /" 6 /4" /" 3" 3/8" " " " /4" /4" /" 3" 3" 3" '-4" '-" 3" '-4" 3" 3" 3" 3" '-" 3" 3" 3". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 3" 3" Graphic Layout: PDIR. SCALE: /" = '-0" Graphic Layout: PDIR. SCALE: /" = '-0" CLIENT / OJECT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. PDIR. Layout Drawings E.8

55 SPECIFICATIONS SIGN PANEL LAYOUTS: INTERP. 6 /" /4" 6" /4" s shown are NOT actual messages. Provided for illustrative purposes only. Refer to message schedule for actual sign messages. Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. Jack Ryan with companions believed to be Butch Cassidy, the Sundance Kid, & the Wild Bunch Baggs, WY, circa 896 Courtesy of Carbon County Museum Dr. Raymond Barber, circa 97 Courtesy of Carbon County Museum '-0 /" /4" '-0" /4" RAINBOW TE-TON BUILDING 6 4th Street The Rainbow-Teton Building was built in 899 as an addition to the Brunswick Hotel located next door. The building soon became the home of Jack Ryan s Home Ranch Saloon where it is believed Ryan laundered money from Wild Bunch robberies. Several other saloons were housed here before the Rainbow Hotel opened on the upper floor, providing cheap rooms to saloon customers in the 940s. Graphic Layouts: INTERP. SCALE: : DR. BARBER S HOME OFFICE 38 5th Street First built by Dr. Raymond Barber in 905, this residence served as his home office until his death in May 946. The nephew of Wyoming governor, Amos Barber, Dr. Barber lived and practiced in Rawlins for over 40 years. Among his achievements: he served as the Union Pacific s Chief Surgeon, the State Penitentiary physician, vice-president of Rawlins National Bank.. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. INTERP. Layout Drawings E.9

56 WASHINGTON ST SPECIFICATIONS SIGN PANEL LAYOUTS: INTERP. s shown are NOT actual messages. Provided for illustrative purposes only. 3'-" /" 3'-0" /" Refer to message schedule for actual sign messages. Panel layouts for ALL sign locations shall be included in shop drawings for review by designer and client. /" '-0" /" ISON RIOT Early images of the Wyoming Penitentiary show only a very small wall around the exterior. Over time, and after many jail breaks, prison wardens constructed the foot concrete wall that currently exists. WYOMING FRONTIER ISON On the north side of the Wyoming Frontier Prison are the workshops and recreation areas. In 9 Governor Joseph M. Carey promoted prison reform and oversaw the construction of recreational facilities. From this time, the prison had its own baseball team. The team played local teams from all over Wyoming and they WOOLEN MILL LICENSE PLATE FACTORY always had a home field advantage. The first prison baseball team performed excellently until the execution of their catcher Joseph Seng in 9. The prison was home to the prison broom factory, license plate factory and woolen mill. Originally made of wood, the building burnt in a prison riot in BROOM FACTORY WOODEN BARRACADE Graphic Layout: INTERP. SCALE: 3"=' JOSEPH SENG 9 9. A concrete structure replaced the Rochelle wooden, and remained in use until the prison closed in 98. At that time the building was torn down while removing the factory equipment. Also in 9, a concrete wall replaced the original wooden barricade after several prisoners successfully escaped. 900s BASEBALL 90s YOU ARE HERE W WALNUT ST 6TH ST U.S. 30 BUSINESS W PINE ST Staff of the Wyoming State Penitentiary in the early 900s. Old Pen Baseball: The baseball team at the Wyoming Penitentiary, called the All Stars, played teams from across Wyoming. They always had the home field advantage. Old Pen from the Rear: Facing south into the backyard of the prison you can see the baseball field and the space where the workshop building once stood. This postcard from the 90s shows where the early wooden workshop once stood. 5TH ST CEDAR ST S FRONT ST W STATE ST W DAVIS ST 3RD ST U.S. 30 BUSINESS W FRONT ST U.S. 30 BUSINESS E CENTER ST. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. INTERP. Layout Drawings E.0

57 F Construction Details

58 SPECIFICATIONS Construction Details Sign Type: GTWY. '-0" 3'-4" '-0" '-0" 3'-4" '-0" The FABRICATOR shall be familiar with all site conditions and shall be responsible for all underground utility checks. The FABRICATOR shall be familiar with all basement/vault locations by obtaining plans from the local municipality Department of Public Works. Where a basement/vault interferes with a proposed location, the sign shall be relocated to a location deemed appropriate by the municipalities Department of Public Works 5" '-5 /" Where relocation is not an option the FABRICATOR will develop the appropriate mounting solution. The solution shall meet all engineering criteria as established by the standard footings (i.e. windloads). Final designs and shop drawings shall be supplied by the fabricator for each of the Break-away poles identified and a WYOMING Registered Professional Engineer is required to sign and seal the submittal of shop drawings. NOTE: ) soil is average with maximum allowable soil pressure of 3,000 pounds per square foot. Soil unit weight of 5 PCF and friction angle of 30 degrees (assumed). 7'-5" '-" 7'-5" ) concrete Strength at 8 days f c=4,000 psi Reinforcement shall be ASTM 36 Fy=60,000 PSI 3" 3) FOLLOW 009 WYDOT DESIGN STANDARDS FOR MATERIAL AND CONSTRUCTION INFORMATION FOR THE SIGN POST BASES AND FOUNDATIONS NOT OTHERWISE SPECIFIED IN THESE CONTRACT DRAWINGS. 4) FOR SIGN POST SIZES REFER TO THE DESIGN INTENT DRAWING SHEETS. '-" 5". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 4" Minimum GRADE 4" Minimum CLIENT / OJECT 3'-0" Minimum 3'-0" Minimum These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Construction Details GTWY. Section Detail: GATE. SCALE: 3/4" = '-0" Section Detail: GATE. SCALE: 3/4" = '-0" F.

59 SPECIFICATIONS Construction Details Sign Type: VDIR. VDIR. VDIR.3 4'-" 9 /" 3'-0" 4 /" "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) 3" x 5" x.50 wall Aluminum rectangle tube 6 3/4" /4" thick Aluminum sheet sign panel. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. /8" thick Aluminum sheet Uplift sign panel /8" thick Aluminum sheet shim Section View: VDIR.-3 SCALE: 3" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Construction Detail VDIR.-3 F.

60 SPECIFICATIONS 8 /" 7'-4" 6'-3" 4 /" Construction Details Sign Type: VDIR.4 VDIR.5 VDIR.6 DEST.3 "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) 5" x 5" x.50 wall Aluminum square tube 6 3/4" /4" thick Aluminum sheet sign panel /8" thick Aluminum sheet Uplift sign panel /8" thick Aluminum sheet shim Section View: VDIR.4-6 SCALE: 3" = '-0" 8 /" 7'-4" 6'-3" 4 /". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) 5" x 5" x.50 wall Aluminum square tube CLIENT / OJECT /4" thick Aluminum sheet sign panel Section View: DEST.3 SCALE: 3" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Construction Detail VDIR.4-6 DEST.3 F.3

61 SPECIFICATIONS Construction Details Sign Type: PARK.3 4'-" 9 /" 3'-0" 4 /" "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) 3" x 5" x.50 wall Aluminum rectangle tube /4" thick Aluminum sheet sign panel Section View: PARK.3 Double Sided SCALE: 3" = '-0" 9 /" 4'-" 3'-0" 4 /". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) 3" x 5" x.50 wall Aluminum rectangle tube /4" thick Aluminum sheet sign panel Section View: PARK.3 Single Sided SCALE: 3" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Construction Details PARK.3 F.4

62 SPECIFICATIONS Construction Details Sign Type: PDIR. '-4 /" 5" '- /" "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) 6 /" 3" x 5" x.50 wall Aluminum rectangle tube /4" thick Aluminum sheet sign panel. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. /8" thick Aluminum sheet Uplift sign panel Section View: PDIR. SCALE: 3" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Construction Detail PDIR. F.5

63 SPECIFICATIONS Construction Details Sign Type: DEST.- '-7" '-9 /" 6'-0" 5'-" 7'-5" 6'-5" 7" 8". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 4" Minimum GRADE 4" Minimum GRADE CLIENT / OJECT 3'-0" Minimum 3'-0" Minimum These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Construction Details DEST.- Section Detail: DEST. SCALE: 3/4" = '-0" Section Detail: DEST. SCALE: 3/4" = '-0" F.6

64 '-3" SPECIFICATIONS Construction Details Sign Type: DEST.4 6 /". Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. '-" '-0" 4" Minimum GRADE CLIENT / OJECT 3'-0" Minimum These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Construction Details DEST.4 Section Detail: DEST.4 SCALE: 3/4" = '-0" F.7

65 Kiosk top /8" thk. Aluminum brake-formed top and bottom, encloses kiosk SPECIFICATIONS Construction Details Sign Type: KIOSK. Three (3) - /4" thk. Aluminum horizontal braces, welded Three (3) - 3" dia. internal support poles "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) NOTE: Nuts are welded to back plate. '-3" Three (3) - 3" dia. internal support poles "Black"-colored tamper-resistant hardware (3/8" Heavy Hex Bolt, Flatwashers and SS Locknut) " X 6" nominal Western Red Cedar, rough cut Map panel /4" thk Phenolic Resin' or Event Posters (printed paper or vinyl mounted to /8" thk Sintra board) /4" thk Aluminum back panel 3'-0" 3/4" '-9 /" 3/4" '-3" Kiosk top /8" thk Aluminum side panels "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) NOTE: Nuts are welded to back plate. /8" thk. Aluminum brake-formed top and bottom, encloses kiosk. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. Section View: KIOSK. SCALE: /" = '-0" Stone concrete formed cap Stone base Section View: KIOSK. SCALE: /" = '-0" These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Construction Details KIOSK. Base plate connection to required footer F.8

66 SPECIFICATIONS /" 6" 3" /" "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) x6 nominal Western Red Cedar, rough cut /4" thick Aluminum sheet post cuff top, stitch weld to two () sides. Construction Details Sign Type: VDIR. VDIR. VDIR.3 VDIR.4 VDIR.5 VDIR.6 ±4 3/4" 3" x 5" x.50 wall Aluminum rectangle tube /4" thick Aluminum sheet post cuff sides, with exposed stitch welds as required. Open space /4" thick Aluminum sheet post cuff, with exposed stitch welds as required. Section View: VDIR.-3 Post Cuff SCALE: 6" = '-0" 3 Top View: VDIR.-3 Post Cuff SCALE: 6" = '-0" 3 /4" thick Aluminum sheet post cuff top, stitch weld to two () sides. /4" thick Aluminum sheet post cuff, with exposed stitch welds as required.. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 4" " 6" Section View: VDIR.-3 Post Cuff SCALE: 6" = '-0" 3" x 5" x.50 wall Aluminum rectangle tube x6 nominal Western Red Cedar, rough cut "Black"-colored tamper-resistant hardware (5/8" Heavy Hex Bolt, Flatwashers and SS Locknut) 4 Front View Elevation Detail: VDIR. SCALE: /4" = '-0" Side View These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Construction Details VDIR.-6 Post Cuff F.9

67 SPECIFICATIONS TRANSPO Break-Safe B55 Sign Type: VDIR. 6, PARK.3, PDIR.. The FABRICATOR shall be familiar with all site conditions and shall be responsible for all underground utility checks. The FABRICATOR shall be familiar with all basement/vault locations by obtaining plans from the local municipality Department of Public Works. Where a basement/vault interferes with a proposed location, the sign shall be relocated to a location deemed appropriate by the municipalities Department of Public Works Where relocation is not an option the FABRICATOR will develop the appropriate mounting solution. The solution shall meet all engineering criteria as established by the standard footings (i.e. windloads). Final designs and shop drawings shall be supplied by the fabricator for each of the Break-away poles identified and a WYOMING Registered Professional Engineer is required to sign and seal the submittal of shop drawings. NOTE: ) soil is average with maximum allowable soil pressure of 3,000 pounds per square foot. Soil unit weight of 5 PCF and friction angle of 30 degrees (assumed). ) concrete Strength at 8 days f c=4,000 psi Reinforcement shall be ASTM 36 Fy=60,000 PSI 3) FOLLOW 009 WYDOT DESIGN STANDARDS FOR MATERIAL AND CONSTRUCTION INFORMATION FOR THE SIGN POST BASES AND FOUNDATIONS NOT OTHERWISE SPECIFIED IN THESE CONTRACT DRAWINGS. 4) FOR SIGN POST SIZES REFER TO THE DESIGN INTENT DRAWING SHEETS.. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Transpo Break-Safe B55 Break-away Footer Details F.0

68 SPECIFICATIONS TRANSPO Break-Safe B55 Sign Type: VDIR. 6, PARK.3, PDIR.. Note: Design Wind load 300 PSF 0 MPH, 3 Sec Gust Wind, Exp C 5" sidewalks 7" driveways 3'-0" Minimum Aluminum Post. Size varies, reference design details for exact size. Transpo B55 Break-Safe Break Away Sign Support Existing Concrete Slab Note: Design Wind load 300 PSF 0 MPH, 3 Sec Gust Wind, Exp C 3'-0" Minimum 4" Aluminum Post. Size varies, reference design details for exact size. Transpo B55 Break-Safe Break Away Sign Support Existing Pavers The FABRICATOR shall be familiar with all site conditions and shall be responsible for all underground utility checks. The FABRICATOR shall be familiar with all basement/vault locations by obtaining plans from the local municipality Department of Public Works. Where a basement/vault interferes with a proposed location, the sign shall be relocated to a location deemed appropriate by the municipalities Department of Public Works Where relocation is not an option the FABRICATOR will develop the appropriate mounting solution. The solution shall meet all engineering criteria as established by the standard footings (i.e. windloads). Final designs and shop drawings shall be supplied by the fabricator for each of the Break-away poles identified and a WYOMING Registered Professional Engineer is required to sign and seal the submittal of shop drawings. NOTE: ) soil is average with maximum allowable soil pressure of 3,000 pounds per square foot. Soil unit weight of 5 PCF and friction angle of 30 degrees (assumed). ) concrete Strength at 8 days f c=4,000 psi Reinforcement shall be ASTM 36 Fy=60,000 PSI 3'-0" Minimum Class B Concrete Footing Reference WYDOT 3'-0" Minimum Class B Concrete Footing Reference WYDOT 3) FOLLOW 009 WYDOT DESIGN STANDARDS FOR MATERIAL AND CONSTRUCTION INFORMATION FOR THE SIGN POST BASES AND FOUNDATIONS NOT OTHERWISE SPECIFIED IN THESE CONTRACT DRAWINGS. 4) FOR SIGN POST SIZES REFER TO THE DESIGN INTENT DRAWING SHEETS. Note: Design Wind load 300 PSF 0 MPH, 3 Sec Gust Wind, Exp C Section View: Concrete SCALE: 3/4" = '-0" Aluminum Post. Size varies, reference design details for exact size. Note: Design Wind load 300 PSF 0 MPH, 3 Sec Gust Wind, Exp C Section View: Pavers SCALE: 3/4" = '-0" Aluminum Post. Size varies, reference design details for exact size.. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 5" sidewalks 7" driveways Transpo B55 Break-Safe Break Away Sign Support Existing Concrete Slab 5" sidewalks 7" driveways Existing Concrete Slab Transpo B55 Break-Safe Break Away Sign Support CLIENT / OJECT '-0" 3 3'-0" square Section View: Foundation: Shallow Depth SCALE: 3/4" = '-0" Class B Concrete Footing Reference WYDOT '-" 4 4'-0" square Section View: Foundation: Extremely Shallow Depth SCALE: 3/4" = '-0" Class B Concrete Footing Reference WYDOT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Transpo Break-Safe B55 Break-away Footer Details F.

69 SPECIFICATIONS TRANSPO Break-Safe AS4 Sign Type: PARK., INTERP.. The FABRICATOR shall be familiar with all site conditions and shall be responsible for all underground utility checks. The FABRICATOR shall be familiar with all basement/vault locations by obtaining plans from the local municipality Department of Public Works. Where a basement/vault interferes with a proposed location, the sign shall be relocated to a location deemed appropriate by the municipalities Department of Public Works Where relocation is not an option the FABRICATOR will develop the appropriate mounting solution. The solution shall meet all engineering criteria as established by the standard footings (i.e. windloads). Final designs and shop drawings shall be supplied by the fabricator for each of the Break-away poles identified and a WYOMING Registered Professional Engineer is required to sign and seal the submittal of shop drawings. NOTE: ) soil is average with maximum allowable soil pressure of 3,000 pounds per square foot. Soil unit weight of 5 PCF and friction angle of 30 degrees (assumed). ) concrete Strength at 8 days f c=4,000 psi Reinforcement shall be ASTM 36 Fy=60,000 PSI 3) FOLLOW 009 WYDOT DESIGN STANDARDS FOR MATERIAL AND CONSTRUCTION INFORMATION FOR THE SIGN POST BASES AND FOUNDATIONS NOT OTHERWISE SPECIFIED IN THESE CONTRACT DRAWINGS. 4) FOR SIGN POST SIZES REFER TO THE DESIGN INTENT DRAWING SHEETS.. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. Transpo Break-Safe AS4 Break-away Footer Details F.

70 SPECIFICATIONS TRANSPO Break-Safe AS4 Sign Type: PARK., INTERP.. Note: Design Wind load 300 PSF 0 MPH, 3 Sec Gust Wind, Exp C 5" sidewalks 7" driveways 3'-0" Minimum x 4 Rectangle Aluminum Post Transpo AS4 Break-Safe Break Away Sign Support Existing Concrete Slab Note: Design Wind load 300 PSF 0 MPH, 3 Sec Gust Wind, Exp C 3'-0" Minimum 4" x 4 Rectangle Aluminum Post Transpo AS4 Break-Safe Break Away Sign Support Existing Pavers The FABRICATOR shall be familiar with all site conditions and shall be responsible for all underground utility checks. The FABRICATOR shall be familiar with all basement/vault locations by obtaining plans from the local municipality Department of Public Works. Where a basement/vault interferes with a proposed location, the sign shall be relocated to a location deemed appropriate by the municipalities Department of Public Works Where relocation is not an option the FABRICATOR will develop the appropriate mounting solution. The solution shall meet all engineering criteria as established by the standard footings (i.e. windloads). Final designs and shop drawings shall be supplied by the fabricator for each of the Break-away poles identified and a WYOMING Registered Professional Engineer is required to sign and seal the submittal of shop drawings. NOTE: ) soil is average with maximum allowable soil pressure of 3,000 pounds per square foot. Soil unit weight of 5 PCF and friction angle of 30 degrees (assumed). ) concrete Strength at 8 days f c=4,000 psi Reinforcement shall be ASTM 36 Fy=60,000 PSI 3'-0" Minimum Class B Concrete Footing Reference WYDOT 3'-0" Minimum Class B Concrete Footing Reference WYDOT 3) FOLLOW 009 WYDOT DESIGN STANDARDS FOR MATERIAL AND CONSTRUCTION INFORMATION FOR THE SIGN POST BASES AND FOUNDATIONS NOT OTHERWISE SPECIFIED IN THESE CONTRACT DRAWINGS. 4) FOR SIGN POST SIZES REFER TO THE DESIGN INTENT DRAWING SHEETS. Note: Design Wind load 300 PSF 0 MPH, 3 Sec Gust Wind, Exp C Section View: Concrete SCALE: 3/4" = '-0" x 4 Rectangle Aluminum Post Note: Design Wind load 300 PSF 0 MPH, 3 Sec Gust Wind, Exp C Section View: Pavers SCALE: 3/4" = '-0" x 4 Rectangle Aluminum Post. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 5" sidewalks 7" driveways Transpo AS4 Break-Safe Break Away Sign Support Existing Concrete Slab 5" sidewalks 7" driveways Existing Concrete Slab Transpo AS4 Break-Safe Break Away Sign Support CLIENT / OJECT '-0" 3 3'-0" square Section View: Foundation: Shallow Depth SCALE: 3/4" = '-0" Class B Concrete Footing Reference WYDOT '-" 4 4'-0" square Section View: Foundation: Extremely Shallow Depth SCALE: 3/4" = '-0" Class B Concrete Footing Reference WYDOT These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Transpo Break-Safe AS4 Break-away Footer Details F.3

71 Aluminum Post (Size varies by sign type) Weep Holes as Required 5" Smooth Concrete Pad SPECIFICATIONS Construction Details Sign Type: KIOSK. INTERP. 5" Below Grade Leveling Nuts 3" Base Concrete Slab 6" Crushed Stone /" thk Aluminum Plates 3'-0" min. Poured in Place Concrete Footer 4,000 8 Days " DIA Steel Bolts w/ Hex Head nut at bottom Typ. vertical rebar as required Provide weather seal sand & footing '-0" Diameter Sonotube Compacted Crushed Stone as Required Section: Bolt w/ Nut Plate-to-Plate MOUNTING Concrete Pavement Surface SCALE: " = ' - 0" 5" Aluminum Post (Size varies by sign type) Weep Holes as Required 5" Brick Pavers Below Grade Leveling Nuts 3" Bitum. Setting Bed 6" Crushed Stone /" thk Aluminum Plates. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. 3'-0" min. '-0" Diameter Sonotube Poured in Place Concrete Footer 4,000 8 Days " DIA Steel Bolts w/ Hex Head nut at bottom Typ. vertical rebar as required Provide weather seal sand & footing Compacted Crushed Stone as Required These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. CLIENT / OJECT OJECT NO. INTERP. Footer Details Section: Bolt w/ Nut Plate-to-Plate MOUNTING Brick Pavers Surface SCALE: " = ' - 0" F.4

72 NOTE: When locating a footer within a single pavement block adjacent to at least expansion joints, the entire block of pavement shall be removed and replaced with the same materials and finish of adjacent sidewalk areas. Plan: Footer Placement SCALE: NTS Varies CL Existing sidewalk block to be removed and replaced Sign Post Footer 3 Plan: Specialty Pavers Footer Placement SCALE: NTS Existing Specialty Pavers to be removed, saved and replaced. Sign Post Footer NOTE: The pattern of bricks need to be removed, stored and replaced in the order they were removed. Marking the Specialty Pavers sidewalk with spray paint will NOT be allowed. SPECIFICATIONS Sidewalk Footer Placement Details The FABRICATOR shall be familiar with all site conditions and shall be responsible for all underground utility checks. The FABRICATOR shall be familiar with all basement/vault locations by obtaining plans from the local municipality Department of Public Works. Where a basement/vault interferes with a proposed location, the sign shall be relocated to a location deemed appropriate by the municipalities Department of Public Works Where relocation is not an option the FABRICATOR will develop the appropriate mounting solution. The solution shall meet all engineering criteria as established by the standard footings (i.e. windloads). Final designs and shop drawings shall be supplied by the fabricator for each of the Break-away poles identified and a WYOMING Registered Professional Engineer is required to sign and seal the submittal of shop drawings. NOTE: ) soil is average with maximum allowable soil pressure of 3,000 pounds per square foot. Soil unit weight of 5 PCF and friction angle of 30 degrees (assumed). ) concrete Strength at 8 days f c=4,000 psi Reinforcement shall be ASTM 36 Fy=60,000 PSI 3) FOLLOW 009 WYDOT DESIGN STANDARDS FOR MATERIAL AND CONSTRUCTION INFORMATION FOR THE SIGN POST BASES AND FOUNDATIONS NOT OTHERWISE SPECIFIED IN THESE CONTRACT DRAWINGS. 4) FOR SIGN POST SIZES REFER TO THE DESIGN INTENT DRAWING SHEETS. Varies CL Class B Concrete Footing Reference State DOT Req. Standards Transpo Break-Safe, or Transpo Pole-Safe Break-Away System Sign Post Preferred Footer Detail BAD Footer Detail. Fabricator to verify the mounting conditions and provide a detail drawing for each mounting situation, prior to fabrication. Fabricator must obtain approval from the Designer or Client for placement prior to fabrication. CLIENT / OJECT Plan View: Footer SCALE: " = ' - 0" Preferred Footer Detail BAD Footer Detail These drawings are meant for DESIGN INTENT ONLY and are not for construction. Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. This office must be notified of any variations from the dimensions and conditions details must be submitted to this office for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department. OJECT NO. Sidewalk Footer Placement Details Preferred Footer Detail BAD Footer Detail F.5

Portsmouth, NH. Wayfinding and Signage System City of Portsmouth, NH Planning Department 100% DESIGN INTENT DRAWINGS.

Portsmouth, NH. Wayfinding and Signage System City of Portsmouth, NH Planning Department 100% DESIGN INTENT DRAWINGS. Portsmouth, NH City of Portsmouth, NH Planning Department 00% DESIGN INTENT DRAWINGS January, 04 Rev: March 4, 04 0 North Church Street Suite 08 West Chester, PA 980 T 484.66.0648 Section SIGN SYSTEM STANDARDS

More information

Missoula, MT. Wayfinding and Signage System 100% DESIGN INTENT DRAWINGS. November 3, 2014

Missoula, MT. Wayfinding and Signage System 100% DESIGN INTENT DRAWINGS. November 3, 2014 Missoula, MT 100% DESIGN INTENT DRAWINGS November 3, 2014 Note: Only sheets related to Phase I project included in BID Document. Section 1 SIGN SYSTEM STANDARDS A. Graphic Standards Typography Specifications...

More information

City of Topeka, Kansas Wayfinding Program. Revised Design Intent - REISSUED. October 10, 2018

City of Topeka, Kansas Wayfinding Program. Revised Design Intent - REISSUED. October 10, 2018 City of Topeka, Kansas Wayfinding Program Revised Design Intent - REISSUED October 0, 08 Lake Wellington Professional Centre Studio Suite 0-Y 6 Ken Adams Way Wellington, FL 56.8.605 axiacreative.com CONTENTS

More information

BUILDING SIGN PROGRAM JULY 2012

BUILDING SIGN PROGRAM JULY 2012 BUILDING SIGN PROGRAM JULY 2012 TABLE OF CONTENTS Introduction... 2 General Information for all Signs... 3 Sign Selection Considerations... 4 Typography... 5 Color Schedule... 6 Glossary... 7 Interior

More information

CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT COLLEGE CAMPUS MASTER SIGN PROGRAM, PHASE 2 BID NO

CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT COLLEGE CAMPUS MASTER SIGN PROGRAM, PHASE 2 BID NO CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT COLLEGE CAMPUS MASTER SIGN PROGRAM, PHASE 2 BID NO. 18-04 ADDENDUM NO. ONE DATE: September 07, 27 CLIENT / PROJECT: Chabot-Las Positas CCD Campus Master

More information

Design Documents for Wayfinding

Design Documents for Wayfinding Design Documents for Wayfinding 11-11-08 FOR FHWA SUBMITTAL 1 2 3 4 5 6 7 8 9 1st AVENUE WEST 3rd AVENUE WEST A B C D E F G H I 15th STREET WEST 14th STREET WEST Historic 2nd AVENUE WEST BARCARROTA BOULEVARD

More information

BUILDING SIGN PROGRAM SEPTEMBER 2016

BUILDING SIGN PROGRAM SEPTEMBER 2016 BUILDING SIGN PROGRAM SEPTEMBER 2016 TABLE OF CONTENTS INTRODUCTION...2 GENERAL INFORMATION FOR ALL SIGNS...3 SIGN SELECTION CONSIDERATIONS...4 TYPOGRAPHY...5 COLOR SCHEDULE...6 GLOSSARY...7 INTERIOR SIGNS

More information

Sign Construction and Implementation Principles

Sign Construction and Implementation Principles Sign Construction and Implementation Principles Revision 3.1 Curtin University Cover page 001 S 2.1 Primary identification Page 004-005 S 4.1 Tertiary identification Page 014-016 Wall Mounted Super-numerals

More information

ATTACHMENT B1. Typical Facility Signage Standards and Guidelines/Sign Types

ATTACHMENT B1. Typical Facility Signage Standards and Guidelines/Sign Types 7006786 TTCHMENT B1 Typical Facility Signage Standards and Guidelines/Sign Types 3.0 3.0 S - TERMINLS/GTE RES - 3.1 Sign Type Index - 3.2 Sign Types INDEX - TERMINLS/GTE RES This chapter provides specific

More information

DOWNTOWN DEVELOPMENT REVIEW BOARD APPLICATION

DOWNTOWN DEVELOPMENT REVIEW BOARD APPLICATION This application, including the Conceptual Review Presentation, must be completed and submitted to the Downtown Development Review Board (DDRB) Staff twenty (20) business days prior to the upcoming DDRB

More information

CITY OF PINE CITY SMALL WIRELESS FACILITY DESIGN GUIDELINES

CITY OF PINE CITY SMALL WIRELESS FACILITY DESIGN GUIDELINES CITY OF PINE CITY SMALL WIRELESS FACILITY DESIGN GUIDELINES I. PURPOSE AND COMPLIANCE In implementing City Code, Chapter 8, Section 815, the City Council of the City of Pine City (the City ) finds that

More information

LARAMIE COUNTY COMMUNITY COLLEGE Clay Pathfinder Interior Wayfinding Signage AUGUST 11, 2017

LARAMIE COUNTY COMMUNITY COLLEGE Clay Pathfinder Interior Wayfinding Signage AUGUST 11, 2017 LARAMIE COUNTY COMMUNITY COLLEGE AUGUST, 07 FABRICATOR PERFORMANCE & MATERIAL REQUIREMENTS This document has been assembled by Tangram Design, LLC (Tangram) for College (Owner) with the expectation that

More information

Addendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs

Addendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs Addendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs Included documents: Principle 7 of the Design Guidelines for Lower Downtown Historic District (June 19, 2007) Sugar

More information

CENTRAL MICHIGAN UNIVERSITY DESIGN STANDARD FOR INTERIOR CAMPUS SIGNAGE - JANUARY 23, 2017

CENTRAL MICHIGAN UNIVERSITY DESIGN STANDARD FOR INTERIOR CAMPUS SIGNAGE - JANUARY 23, 2017 CENTRAL MICHIGAN UNIVERSITY DESIGN STANDARD FOR INTERIOR CAMPUS SIGNAGE - JANUARY 23, 2017 TABLE OF CONTENTS 1 INTRODUCTION Goals Purpose Sign Types How to Use This Document 2 DESIGN CRITERIA Application

More information

DRAFT V. SITE ELEMENTS SIGNS

DRAFT V. SITE ELEMENTS SIGNS 1. SIGNS Intent Signs are an important streetscape design element that affect not only the visual character of the Historic District but also the vitality of its businesses. Signage provides business identification,

More information

Palm Beach Community College

Palm Beach Community College Palm Beach Community College 2006 S I G N A G E S T A N D A R D S M A N U A L Exterior and Interior Sign Standards Users Guide Prepared by TA B L E O F C O N T E N T S Introduction...2 Color Palette...5

More information

Guide Sign Policy for Secondary State Highways Edition

Guide Sign Policy for Secondary State Highways Edition Massachusetts Highway Department, Ten Park Plaza, Boston, MA 02116-3973 ` Guide Sign Policy for Secondary State Highways 2005 Edition Revised September 2005 1. PURPOSE The Massachusetts Highway Department

More information

INTERIOR SIGNAGE MANUAL

INTERIOR SIGNAGE MANUAL INTERIOR SIGNAGE MANUAL ➊ Purpose ➋ Procedures ➌ ADA Requirements INTERIOR SIGNAGE MANUAL ➍ Text, Braille, Pictograms and Color ➎ Families of Interior Signage ➏ Mounting Guidelines ➐ Signage Diagrams ➑

More information

Introduction: Directional Signs

Introduction: Directional Signs Introduction: Directional Signs EP 310-1-6a Well planned and properly designed directional signs are important visitor aids. They lead visitors to a Corps project, direct them to the various recreation

More information

Leesburg, Florida W a y finding Pla n

Leesburg, Florida W a y finding Pla n Submittal To: Florida Department of Transportation, Florida W a y finding Pla n Revised: January 17, 2013 January 15, 2013 January 9, 2012 October 11, 2012 GRAPHIC DESIGN & WAYFINDING What is a wayfinding

More information

Town of Innisfail Wayfinding and Signage Program Specifications

Town of Innisfail Wayfinding and Signage Program Specifications January 10, 2017 Rev. May 24, 2017 2017 BO Creative Inc. Sign Schedule Sign No. Qty. escription Remarks rawing No. Sign Schedule - B.01 Materials and Finishes - B.02 Sign Plot - B.03 Colour Inventory -

More information

BUS RAPID TRANSIT FOURTH PLAIN BLVD

BUS RAPID TRANSIT FOURTH PLAIN BLVD K SIGN TYPE C BAY ID INTERNALLY ILLUMINATED, DOUBLED-SIDED SIGN CABINET MOUNT TO LIGHT POLE BY OTHERS AT DRIVER STOP LINE. ALUMINUM CABINET, DIGITALLY PRINTED GRAPHIC MOUNTED TO POLYCARBONATE LENS. 22'

More information

Table of Contents. Ninety Edge. BevelED Edge. Reveal Collection ENCLOSURES 7 KIOSKS 8 ARC ENCLOSURES 9 KIOSKS 10. Carve collection.

Table of Contents. Ninety Edge. BevelED Edge. Reveal Collection ENCLOSURES 7 KIOSKS 8 ARC ENCLOSURES 9 KIOSKS 10. Carve collection. Enclosures & Kiosks Table of Contents Ninety Edge ENCLOSURES 3 KIOSKS 4 BevelED Edge ENCLOSURES 5 KIOSKS 6 Reveal Collection ENCLOSURES 7 KIOSKS 8 ARC ENCLOSURES 9 KIOSKS 10 Carve collection ENCLOSURES

More information

Introduction. Page 1. Welcome to the signage guidelines for St John Ambulance premises, updated as of September 2012.

Introduction. Page 1. Welcome to the signage guidelines for St John Ambulance premises, updated as of September 2012. Signage guidelines Introduction Welcome to the signage guidelines for St John Ambulance premises, updated as of September 2012. These guidelines provide a signage standard for all St John Ambulance buildings,

More information

Campus Signage Program. exterior signage. Revised December 2017

Campus Signage Program. exterior signage. Revised December 2017 Campus Signage Program exterior signage TABLE OF CONTENTS Exterior Signage Executive Summary i Sign Type A Pedestrian Directive with Additional Information.0 Sign Type B Pedestrian Location Map. General

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II SECTION 101400 - SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and supplementary Conditions and Division-1 Specification Sections,

More information

CITY OF RICHMOND Notice of Public Opening. Contract: Richmond Speed Skating Oval Interior/ Exterior Signage Package

CITY OF RICHMOND Notice of Public Opening. Contract: Richmond Speed Skating Oval Interior/ Exterior Signage Package CITY OF RICHMOND CITY OF RICHMOND Notice of Public Opening Contract T.3263 Contract: Richmond Speed Skating Interior/ Exterior Signage Package Tenders have been issued for the Richmond Speed Skating Interior/

More information

Architectural Excellence

Architectural Excellence Architectural Excellence 0 River Road Verona, PA 47 Tel: 4.80.00 Fax: 4.80.4404 www.buntinggraphics.com Sign Programs for Libraries Company Background Bunting Graphics is a high quality architectural fabricator

More information

Exterior Signage. Design Development 75% 30 November, In collaboration with:

Exterior Signage. Design Development 75% 30 November, In collaboration with: Exterior Signage Design Development 75% 30 November, 2016 In collaboration with: Identity ABCDEFGHIJKLMNOPQRSTUVWXYZ 1234567890 abcdefghijklmnopqrstuvwxyz Antenna Regular ABCDEFGHIJKLMNOPQRSTUVWXYZ 1234567890

More information

SECTION INTERIOR SIGNAGE

SECTION INTERIOR SIGNAGE PART 1 - GENERAL 1.1 DESCRIPTION SECTION 10 14 05 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete //-----//if not applicable to project. Also delete any other item or paragraph

More information

CHAPTER TWO Fire Lanes & Fire Access

CHAPTER TWO Fire Lanes & Fire Access Contents: CHAPTER TWO Fire Lanes & Fire Access Access Requirements for New Construction Sites Fire Lane Signs and Installations Alternative Fire Lane Signs Fire Lane Identification (Red Painted Curbs)

More information

Agenda Item: Revised Master Sign Plan Windsor Run Retirement Center

Agenda Item: Revised Master Sign Plan Windsor Run Retirement Center Agenda Item: Revised Master Sign Plan Retirement Center DATE: November 1, 2017 FROM: Mary Jo Gollnitz, Planner Background/Issue: EMH&T is requesting a revision to Retirement Center Master Sign Plan approved

More information

SHOWCASING OUR VIBRANCY. Technical Supplement to the Y Graphic Standards for Signage YMCA OF THE USA

SHOWCASING OUR VIBRANCY. Technical Supplement to the Y Graphic Standards for Signage YMCA OF THE USA SHOWCASING OUR VIBRANCY Technical Supplement to the Y Graphic Standards for Signage YMCA OF THE USA REVISED 08.22.2014 TABLE OF CONTENTS 3 INTRODUCTION 4 APPLYING GRAPHIC STANDARDS 5 VISUAL SYSTEM OVERVIEW

More information

Traffic Line Painting and Other Pavement Markings

Traffic Line Painting and Other Pavement Markings Gateway to the 1000 Islands QUOTATION FOR: Traffic Line Painting and Other Pavement Markings QUOTATION CLOSING: May 23, 2013 QUOTATION NUMBER: RDS-2013-02 Submit completed quotations to: Quotation for

More information

SECTION INTERIOR SIGNAGE

SECTION INTERIOR SIGNAGE SECTION 10 14 02 INTERIOR SIGNAGE PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by

More information

OVERVIEW OF SIGN BY-LAW HERITAGE GUIDELINES

OVERVIEW OF SIGN BY-LAW HERITAGE GUIDELINES OVERVIEW OF SIGN BY-LAW Formatted: Font: (Default) Arial, 12 pt & HERITAGE GUIDELINES Formatted: Font: 12 pt To regulate signage and all other advertising devices in the Town of Cobourg, Council approved

More information

Tenant Sign Criteria. Guidelines. Requirements. Braelinn Village, Peachtree City

Tenant Sign Criteria. Guidelines. Requirements. Braelinn Village, Peachtree City Guidelines Requirements The purpose of sign criteria is to establish certain parameters for sign design, locations, materials, size, construction and installation. As a quality development within Peachtree

More information

Introduction: Identification Signs

Introduction: Identification Signs Introduction: Identification Signs EP 310-1-6a ll Corps projects and facilities are identified with a Standard Identification sign. The graphic format has been standardized for use at all locations. The

More information

SECTION EDITION - REVISION 2. Large Guide

SECTION EDITION - REVISION 2. Large Guide SECTION 4 0 EDITION - REVISION Large Guide March 017 (This page left intentionally blank) Guide Sign Design Guidelines Design Guidelines There are general guidelines to follow in the design of highway

More information

Prepared by: Facilities Planning, Design & Construction Utah State University 1295 East 700 North 6605 Old Main Hill Logan, UT

Prepared by: Facilities Planning, Design & Construction Utah State University 1295 East 700 North 6605 Old Main Hill Logan, UT SIGNAGE STANDARDS Prepared by: Facilities Planning, Design & Construction Utah State University 1295 East 700 North 6605 Old Main Hill Logan, UT 84321-6605 435-797-3737 November 2010 T A B L E O F C O

More information

Temporary Sign Permit

Temporary Sign Permit 36725 Division Road, P.O. Box 457, Richmond, MI 48062 Building and Planning Department 586-727-7571 ext. 228 586-727-2489 Fax Temporary Sign Permit Application and Regulations Page 1 Updated: 15OCT15 Temporary

More information

SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM

SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM SECTION 10445 NON-ILLUMINATED INTERIOR DISPLAY SYSTEM FullView Display System includes concealed pin lock device to secure a clear cover and/or sign insert material into the frame. Vandal resistant. PART

More information

OVERVIEW OF SIGN BY-LAW HERITAGE GUIDELINES

OVERVIEW OF SIGN BY-LAW HERITAGE GUIDELINES OVERVIEW OF SIGN BY-LAW Formatted: Font: (Default) Arial, 12 pt & HERITAGE GUIDELINES Formatted: Font: 12 pt To regulate signage and all other advertising devices in the Town of Cobourg, Council approved

More information

Uniform Sign Plan (USP) MacGregor Village 86-USP-003

Uniform Sign Plan (USP) MacGregor Village 86-USP-003 Uniform Sign Plan (USP) MacGregor Village 86-USP-003 These guidelines are published for informational purposes. They describe the characteristics of signs, not structures on which signs are placed. A sign

More information

Environmental graphics

Environmental graphics gym floor When a gym floor is being updated from the old logo, it is not necessary to replace the old logo with the new one. Ys may have a gym floor without a logo and instead feature the new logo on a

More information

SECTION SIGNAGE

SECTION SIGNAGE SECTION 10 14 00 SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification section, apply

More information

A. Submit manufacturer's technical data and installation for each type of sign required.

A. Submit manufacturer's technical data and installation for each type of sign required. SECTION 10425 PART ONE GENERAL 1.1 SECTION INCLUDES A. Interior Building Signage. B. Handicapped parking signs. C. Permanent Project Sign. 1.2 DESCRIPTION A. Signage shall consist of room number and room

More information

Fabrication Design Intent Specification Documents

Fabrication Design Intent Specification Documents Fabrication Design Intent Specification Documents February 0 Table of ontents: VR over 00-0 - Reference of All Signs 00-0 - General Requirements 00-0 - olour Finish Schedule 00-0 - Typography Standards

More information

Americans with Disabilities Act (ADA) Federal Guidelines

Americans with Disabilities Act (ADA) Federal Guidelines Americans with Disabilities Act (ADA) Federal Guidelines The information provided here is distilled from the 2010 ADAAG Final Rule and the ANSI A117.1-2010 Standards and shall be applied to all building

More information

Bovard Studios Inc. Section April 6, 2004 Page 1

Bovard Studios Inc. Section April 6, 2004 Page 1 April 6, 2004 Page 1 This section includes solid flush and surface articulated wood doors, may have veneer facing, solid or glazed (stained glass) design, factory pre-fit, may be factory finished or site

More information

Construction Guidelines 1

Construction Guidelines 1 Construction Guidelines 1 Addendum Log November, 2014 Full Update March, 2015 Formatting July, 2015 Editing November, 2016 Full Update February, 2017 Complete Overhaul Signage Criteria 2 Table of Contents

More information

INTERIOR DESIGN INTENT DRAWINGS - condensed version

INTERIOR DESIGN INTENT DRAWINGS - condensed version INTERIOR DESIGN INTENT DRAWINGS - condensed version 8.10.2018 COMMENTS ADDED 11-11-16 D ~6" 1'-3 5" 2 1/2" 1/2" 5'-2" 6 5/8" 1/2" 3 1/2" Custom fabricated, double-sided cabinet with painted custom radius

More information

2' x 3' Polymer Pull Box Cover 4'-0" 7'-0" 24" x 76" Access Opening 3'-6"

2' x 3' Polymer Pull Box Cover 4'-0 7'-0 24 x 76 Access Opening 3'-6 Scope.1 Precast Concrete Equipment Slab Box 8' x 10' x Pad with 4' x 7' x 3'- Box for 5-Way RAM Gas Switch, 2-Way, 3-Way, and 4-Way Pad-Mounted RAG Gas Switches, VFI 9, VFI 12, Bypass Switch, and 33 kv

More information

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS A. Drawings and General Provisions of Contract, including General and Supplementary Conditions and

More information

Wayfinding Signage Wesbrook Village, UBC

Wayfinding Signage Wesbrook Village, UBC Wesbrook Village, UBC PUBLIC ARCHITECTURE + COMMUNICATION MAY 14, 2015 DEVELOPMENT PERMIT SL 2.0 SL 1.0 Two-sided Copyright reserved. This design and drawing is the SL 4.0 NO DESCRIPTION North Side SL

More information

A. Product Data: For each electrical identification product indicated.

A. Product Data: For each electrical identification product indicated. SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Letter from the President

Letter from the President Letter from the President Dear Friends and Members of the Hyundai Family: Everyday, each one of us strives for improvement in our work as we collectively take one small step closer on our long journey

More information

CITY OF TOMBALL. Section FIRE HYDRANTS 1.01 SECTION INCLUDES. A. Fire hydrants. B. Adjustment of fire hydrants and gate valves.

CITY OF TOMBALL. Section FIRE HYDRANTS 1.01 SECTION INCLUDES. A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. Section 02520 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 MEASUREMENT AND PAYMENT A. Unit Prices. 1. Payment is on a unit price basis

More information

Signage systems by ETC

Signage systems by ETC Signage systems by ETC Built-up Premium Metal Letters 2 Fabricated Signage 7 Fabricated Totems & Monoliths 10 Flat Cut Metal Letters 12 Luxury Illuminated Letters 14 Electro-Tech Colour Ltd. 1 Blenheim

More information

SUPPORT ROADS ALL AIRPORT SERVICES BUILDINGS. ONLY CARGO BUILDINGS (Tenants) Sign Types Summary SIGN TYPES - A.SERVICES

SUPPORT ROADS ALL AIRPORT SERVICES BUILDINGS. ONLY CARGO BUILDINGS (Tenants) Sign Types Summary SIGN TYPES - A.SERVICES Sign Types Summary 3.1 Sign Types Usage Summary 3.1.1 This sub-section summarizes the sign types regulated by this document and their usage in the area. There are three areas into which these sign types

More information

CITY OF OLIVETTE SITE PLAN AND COMMUNITY DESIGN REVIEW INFORMATION PACKET

CITY OF OLIVETTE SITE PLAN AND COMMUNITY DESIGN REVIEW INFORMATION PACKET CITY OF OLIVETTE SITE PLAN AND COMMUNITY DESIGN REVIEW INFORMATION PACKET THE FOLLOWING PACKET CONTAINS: PETITION FOR NONRESIDENTIAL DEVELOPMENT SITE PLAN AND COMMUNITY DESIGN REVIEW SCHEDULE OF DATES

More information

KNIGHT CANCER INSTITUTE KNIGHT CANCER INSTITUTE

KNIGHT CANCER INSTITUTE KNIGHT CANCER INSTITUTE 1 1/4" 1'-2" INDIVIDUAL LETTERS: Colite LP4 Face Lit Letters (or equal) with silver metallic translucent vinyl over white acrylic faces and painted opaque returns. Sign appears silver metallic during the

More information

SIGN TYPES 3/3/ SIGN TYPES SIGNAGE STANDARDS MANUAL STATION SIGNS. Sign Types 8.0

SIGN TYPES 3/3/ SIGN TYPES SIGNAGE STANDARDS MANUAL STATION SIGNS. Sign Types 8.0 8.0 Sign Types 8.0 8a.0 IDENTIFICATION SIGNAGE SIGNAGE STANDARDS MANUAL - STATION SIGNS Identification Signage 8a.0 8a.1 Cast Bronze Pin-Mounted Station Names - Wall Mounted 1. Cast bronze pin-mounted

More information

Town of Burlington Small Wireless Facility. and similar structures. Design Rules and Regulations

Town of Burlington Small Wireless Facility. and similar structures. Design Rules and Regulations Town of Burlington Small Wireless Facility and similar structures Design Rules and Regulations This policy describes approved aesthetic and location criteria for Small Wireless Facilities in the Town of

More information

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS SECTION 3 IMPROVEMENT PLAN REQUIREMENTS CONTENTS Page 3-1 Digital Submittals 3-2 3-2 Paper Size and Scale 3-2 3-3 Drafting Standard 3-2 3-4 Title Sheet 3-2 3-5 Title Block 3-3 3-6 Drainage, Sewer, Water,

More information

DEVELOPMENT SERVICES SITE PLAN SUBMITTAL 2.2.3

DEVELOPMENT SERVICES SITE PLAN SUBMITTAL 2.2.3 DEVELOPMENT SERVICES SITE PLAN SUBMITTAL 2.2.3 Unified Development Code (UDC) Article 2, Applications, Procedures and Criteria provides the steps for applying the Unified Development Code standards to

More information

*********************************************************************************************************

********************************************************************************************************* 10400 IDENTIFYING DEVICES ********************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 10 14 00 *********************************************************************************************************

More information

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM). PART 1 - GENERAL 1.1 SECTION INCLUDES A. Benches. B. Trash receptacles. C. Bike storage. 1.2 REFERENCE STANDARDS A. Including but not limited to: 1. American Society for Testing and Materials (ASTM). 1.3

More information

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations The following specification refers to the Stepstone, Inc. product known as: Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations Large Scale CalArc Pavers are part of the California Architectural

More information

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT SECTION 21 05 53 IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2015-2015 ARCAT, Inc. - All rights reserved PART 1 GENERAL

More information

UNIVERSITY OF HAWAI I AT HILO E OLA KA LELO HAWAI I

UNIVERSITY OF HAWAI I AT HILO E OLA KA LELO HAWAI I UNIVERSITY OF HAWAI I AT HILO E OLA KA LELO HAWAI I PHASE 3: 50% Signage Standards Guidelines JANUARY 20, 2015 TWO TWELVE Table of Contents 1. Introduction 4. Exterior Sign Types 5. Interior Sign Types

More information

Summary of Modifications/Changes in this Update

Summary of Modifications/Changes in this Update Summary of Modifications/Changes in this Update This Summary of Changes is for information only. It is not a part of the referenced document, and should not be used for project documentation. U.S. Department

More information

SIGN PERMIT APPLICATION

SIGN PERMIT APPLICATION SIGN PERMIT APPLICATION City of Hawaiian Gardens Community Development Department 21815 Pioneer Boulevard, Hawaiian Gardens, CA 90716 Ph: (562) 420-2641 Fax: (562) 420-8521 www.hgcity.org Please complete

More information

PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA

PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA Approved: PC Reso No. 430 (05) September 12, 2005 Amended: PC Reso No. 583 (08) March 12, 2008 Palm Square Shopping Center Page 1 PALM SQUARE SHOPPING CENTER

More information

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe Markers. 2. Valve Tags. 3. Equipment Nameplates. 4. Underground Marking Tape. 5. Duct

More information

Operating Standards Attachment to Development Application

Operating Standards Attachment to Development Application Planning & Development Services 2255 W Berry Ave. Littleton, CO 80120 Phone: 303-795-3748 Mon-Fri: 8am-5pm www.littletongov.org Operating Standards Attachment to Development Application 1 SKETCH PLANS

More information

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CITY OF LA MARQUE CHAPTER 2 -------------------------------------------- GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CHAPTER 2 ------------------------------------------------

More information

WILTON MANORS, Island City 2020 WILTON DRIVE, WILTON MANORS, FLORIDA 33305

WILTON MANORS, Island City 2020 WILTON DRIVE, WILTON MANORS, FLORIDA 33305 WILTON MANORS, Island City 2020 WILTON DRIVE, WILTON MANORS, FLORIDA 33305 COMMUNITY DEVELOPMENT SERVICES (954) 390-2180 FAX: (954) 567-6069 This package includes: General Submittal Procedures Submittal

More information

CHAPTER 14: TRAFFIC SIGNAL STANDARDS Introduction and Goals Administration Standards Standard Attachments 14.

CHAPTER 14: TRAFFIC SIGNAL STANDARDS Introduction and Goals Administration Standards Standard Attachments 14. 14.00 Introduction and Goals 14.01 Administration 14.02 Standards 14.03 Standard Attachments 14.1 14.00 INTRODUCTION AND GOALS The purpose of this chapter is to outline the City s review process for traffic

More information

Brand Guidelines 12 December 2014

Brand Guidelines 12 December 2014 Brand Guidelines 12 December 2014 Our brand Introduction A distinctive new approach to the transport infrastructure of Edinburgh deserves a bold new look. A whole new brand platform has been developed

More information

Winnetka Design Review Board. Regular Meeting. August 17, :00 pm

Winnetka Design Review Board. Regular Meeting. August 17, :00 pm Winnetka Design Review Board Regular Meeting August 17, 2017-7:00 pm The Winnetka Design Review Board will hold a meeting on Thursday, August 17, 2017 at Winnetka Village Hall, 510 Green Bay Road, Winnetka,

More information

2013 Feeney (2/14) # B. Aluminum Railing Systems

2013 Feeney (2/14) # B. Aluminum Railing Systems 2013 Feeney (2/14) #2012-425B Aluminum Railing Systems Aluminum Railing Systems Searching For a Complete Railing System? Look No Further. DesignRail by feeney aluminum railing frame systems combine the

More information

AJG 8-1/2" 13'-6" 2'-1 1/4" 3'-6" NIGHT VIEW N.T.S. ANIMART MADISON, WI MICHAEL OLKWITZ P-A. side view TURQUOISE AKZO NOBEL 331-A3

AJG 8-1/2 13'-6 2'-1 1/4 3'-6 NIGHT VIEW N.T.S. ANIMART MADISON, WI MICHAEL OLKWITZ P-A. side view TURQUOISE AKZO NOBEL 331-A3 8-1/ 13'-" 3'-" building fascia 1" 2'-1 1/4" side view Exhibit D previously approved by the U.D.C. S/F ILLUMINATED EXTERIOR CABINET MOUNTED TO BUILDING FASCIA 12-11-0 FABRICATE CABINET FROM ABC SMALL A..125

More information

Corporate Brand Standards

Corporate Brand Standards Rev. February 2016 For external use. Overview The Gordon Food Service logo capitalizes on two key equity elements: 1. Color 2. Shape The Gordon Food Service logo is clean, strong, identifiable, and modern

More information

Washington County Road Engineering Plan Submittal/Review Checklist

Washington County Road Engineering Plan Submittal/Review Checklist Washington County Road Engineering Plan Submittal/Review Checklist Washington County Land Use Case File Number: Parcel(s): Developer/Owner Name(s): Developer/Owner E-mail(s): The following elements should

More information

For a professional approach to your sign needs, consult a professional team.

For a professional approach to your sign needs, consult a professional team. POST MOUNTED SIGN SYSTEMS INTRODUCTION FIRST IMPRESSIONS When attracting new custom, your Company sign is often the primary thing to be noticed, so first impressions are paramount. Location, design, colour

More information

A. Submit properly identified manufacturer's literature before starting work.

A. Submit properly identified manufacturer's literature before starting work. SECTION 10400 IDENTIFYING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Labor and materials required for installation of plaque, school name and address numbers, directional signage, signage

More information

designmasterfence.com

designmasterfence.com designmasterfence.com > INDEX > WHAT IS DESIGNMASTER? > PRODUCTS APPLICATIONS 2 3 > CLASSIC FENCE PANEL Specs & Advantages > CLASSIC FENCE POST Specs, Advantages & Installation > BRACKETS & ACCESSORIES

More information

APPLICATION FOR CERTIFICATE OF APPROPRIATENESS IN THE HISTORIC DESIGN REVIEW DISTRICT

APPLICATION FOR CERTIFICATE OF APPROPRIATENESS IN THE HISTORIC DESIGN REVIEW DISTRICT 209 South Main Street Marysville, Ohio 43040 Phone: (937) 645-7350 Fax: (937) 645-7351 www.marysvilleohio.org APPLICATION FOR CERTIFICATE OF APPROPRIATENESS IN THE HISTORIC DESIGN REVIEW DISTRICT *** IMPORTANT

More information

Elite. PLANNING GUIDE builder & architect edition. AmeriGlide Accessibility Solutions RESIDENTIAL ELEVATOR. ASME A17.1, Part V, Section 5.

Elite. PLANNING GUIDE builder & architect edition. AmeriGlide Accessibility Solutions RESIDENTIAL ELEVATOR. ASME A17.1, Part V, Section 5. Elite RESIDENTIAL ELEVATOR builder & architect edition ASME A17.1, Part V, Section 5.3 June 18, 2018 All information found in s Elite Elevator Planning Guide reflects information at the time of printing.

More information

1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management.

1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management. WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 10 SPECIALTIES SECTION 101410 INTERIOR SIGNAGE PART 1 - GENERAL 1.1. Any deviance from the following requirements must be approved during design

More information

DIVISION PAVEMENT MARKINGS AND MARKERS

DIVISION PAVEMENT MARKINGS AND MARKERS DIVISION 61 66 PAVEMENT MARKINGS AND MARKERS 66.01 SCOPE: The purpose of these specifications is to describe the minimum requirements of the City of Chesapeake for pavement markings and shall be in addition

More information

FUTURE PARKING (5) LEGEND PROPERTY LIMIT CURB & GUTTER EASEMENT BUILDING RETAINING WALL WETLAND LIMITS TREELINE SAWCUT LINE SIGN PIPE BOLLARD NUMBER O

FUTURE PARKING (5) LEGEND PROPERTY LIMIT CURB & GUTTER EASEMENT BUILDING RETAINING WALL WETLAND LIMITS TREELINE SAWCUT LINE SIGN PIPE BOLLARD NUMBER O FUTURE PARKING (5) LEGEND PROPERTY LIMIT CURB & GUTTER EASEMENT BUILDING RETAINING WALL WETLAND LIMITS TREELINE SAWCUT LINE SIGN PIPE BOLLARD NUMBER OF PARKING STALLS PER ROW PROPOSED EXISTING STANDARD

More information

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Installation Instructions for Standard Lap and Self-Aligning Lap Siding Installation Instructions for Standard Lap and Self-Aligning Lap Siding 7/16 in. Standard Laps Include: All Old Mill Widths, Cedar Shake Lap and Smooth Lap 1/2 in. Self-Aligning Include: 8 in. and 12 in.

More information

A. Extent of structural precast concrete work is shown on drawings and in schedules.

A. Extent of structural precast concrete work is shown on drawings and in schedules. SECTION 03 41 00 - STRUCTURAL PRECAST CONCRETE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification

More information

DESIGN REVIEW BOARD APPLICATION EXTERIOR PLAN / LANDSCAPE PLAN

DESIGN REVIEW BOARD APPLICATION EXTERIOR PLAN / LANDSCAPE PLAN 209 S. Main Street Marysville, Ohio 43040 Phone: (937) 645-7350 Fax: (937) 645-7351 www.marysvilleohio.org DESIGN REVIEW BOARD APPLICATION EXTERIOR PLAN / LANDSCAPE PLAN *** IMPORTANT INFORMATION Please

More information

PATHWAY 3G MODULAR ACCESS SYSTEM

PATHWAY 3G MODULAR ACCESS SYSTEM PATHWAY 3G MODULAR ACCESS SYSTEM TECHNICAL & ARCHITECTURAL SPECIFICATIONS Manufactured in the USA Homecare Products, Inc. All rights reserved. All text and images contained in this document are proprietary

More information

LP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information

LP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture A B A - Open / Closed (Page 5) B - Vented (Page 6) ON SITE STORAGE Store off the ground well supported, on a flat well-drained

More information

DOWNTOWN ELON LOGO and SIGNAGE+GRAPHICS CONCEPT JANUARY 2014

DOWNTOWN ELON LOGO and SIGNAGE+GRAPHICS CONCEPT JANUARY 2014 LOGO and SIGNAGE+GRAPHICS CONCEPT JANUARY 2014 LOGO SELECTION A SUCCESSFUL LOGO MUST... WORK IN BLACK + WHITE single color use underlines a strong logo design BE VERSATILE FOR MULTI-USE flexible to be

More information

Guide Specification Section Interior Suspended Sliding Glass Doors

Guide Specification Section Interior Suspended Sliding Glass Doors Guide Specification Section 08 32 13 Interior Suspended Sliding Glass Doors SECTION 08 32 13 The Sliding Door Company s product combines operable sliding glass doors with stationary glazed panels to create

More information