KNIGHT CANCER INSTITUTE KNIGHT CANCER INSTITUTE
|
|
- Terence Phillips
- 5 years ago
- Views:
Transcription
1 1 1/4" 1'-2" INDIVIDUAL LETTERS: Colite LP4 Face Lit Letters (or equal) with silver metallic translucent vinyl over white acrylic faces and painted opaque returns. Sign appears silver metallic during the day and white faces at night when lighted. Letters are mounted to the aluminum frame using threaded fasteners, drill and tap method.font: Myriad SemiBold Condensed. All capital letters. 14'-9 1/2" KNIGHT CANCER INSTITUTE Sign Type Ix-6a Individual Letters 1/2" = 1'-0" 1/4" 1'-4 1/4" ALUMINUM FRAME: Cutout 1/4" aluminum plate frame with bottom flange break-formed for attachment to U-channel and painted to match - silver metallic and dark gray. 3/8" x 1 1/4" aluminum bar mechanically fastened to backer frame using stainless steel fasteners and painted to match metallic silver. Sign must be appearance grade when viewed from behind. KNIGHT CANCER INSTITUTE 5" 14'-11" 3" 1 3/4" ELECTRICAL FEED: Custom fabricate aluminum raceway with weather tight access panels to support necessary transformers and painted to match - dark gray. Use GTO sleeving for power supply conduit. KNIGHT CANCER INSTITUTE Design ReviewIntent LETTERS AND FRAME ASSEMBLED FRONT VIEW Equal sections of raceway covers (Removeable) TOP VIEW 49
2 WEST ELEVATION A317: Letter Detail INTERNALLY ILLUMINATED INDIVIDUAL LETTERS The total area of the sign equals 38.9 sq ft 29'-8" 1'-3 3/4" 1'-3 3/4" 1'-6 1/2" FONT: Myriad SemiBold Condensed. All capital letters. SERA & Fabricator to verify dimensions and location prior to fabrication and installation. 6'-5 1/8" FRONT VIEW Ix-6b INDIVIDUAL LETTERS : 1/4 = 1-0 on an 11 x 17 sheet 50
3 1 3/16" INDIVIDUAL LETTERS: Colite LP4 Face Lit Letters (or equal) with metallic silver translucent vinyl over white acrylic faces and painted opaque returns. Sign appears metallic silver during the day and white faces at night when lighted. Letters are mounted to the aluminum frame using threaded fasteners, drill and tap method. 1'-3 3/4" 1/4" ALUMINUM FRAME: Cutout 1/4" aluminum plate frame with bottom flange break-formed for attachment to U-channel and painted to match - metallic silver and dark gray. 3/8" x 1 1/4" aluminum bar mechanically fastened to backer frame using stainless steel fasteners and painted to match metallic silver. 1'-6 1/2" 6 1/4" 29'- 8" ELECTRICAL FEED: Custom fabricate aluminum raceway with weather tight access panels to support necessary transformers and painted to match - dark gray. Use GTO sleeving for power supply conduit. SECTION A 1'-3 3/4" 1'-6 1/2" 6 1/4" 5 1/4" LETTERS AND FRAME ASSEMBLED FRONT VIEW 4'-11 3/4" EQUAL SECTIONS OF RACEWAY COVERS (removeable) 1/4" 6" 1 3/16" TOP VIEW Ix-6b INDIVIDUAL LETTERS - DETAIL : 1/2 = 1-0 on an 11 x 17 sheet 51
4 Ix-6b Individual Letters Detail 3" = 1'-0" Letters attached to backer using countersunk stainless steel fasteners LP4 FACE LIT LETTERS BY COLITE: White acrylic with white LED lighting embedded into acrylic 1/4" aluminum backer frame with cutout letter forms with break-formed base at 90 add gussets if necessary. Mount to U-channel using stainless steel mechanical fasteners. 1'-3 3/4" Drill holes for necessary access for power supply at base of letters. Custom raceway cover using 1/8 thick aluminum panel mounted to backer using L-brackets using countersunk stainless steel fasteners. 1'-6 1/2" 3/8" x 1 1/4" aluminum bar mechanically fastened to backer frame using stainless steel fasteners. Custom aluminum fabricated U-channel painted to match canopy rafter. Mechanically fasten to rafter using stainless steel nut and bolt fasteners. Fabricator to field measure canopy rafter for tight fit and match bottom angle. DETAIL: The above detail is for reference only and is not final. Fabricator to engineer letter attachment. 2" ELECTRICAL FEED: Owner is responsible for providing the electrical feed to the to sign. Fabricator to provide shop drawings showing detail of electrical location and specifications. Fabricator to provide final connection. 5 1/4" Design Intent 6 1/4" SECTION A LOOKING SOUTH 52
5 Ix-6b Building Name Detail 1 3/16" INDIVIDUAL LETTERS: Colite LP4 Face Lit Letters (or equal) with metallic silver translucent vinyl over white acrylic faces and painted opaque returns. Sign appears metallic silver during the day and white faces at night when lighted. Letters are mounted to the aluminum frame using threaded fasteners, drill and tap method. 21'-6" 1/2" = 1'-0" 1'-6" 1'-9" 1/4" ALUMINUM FRAME: Cutout 1/4" aluminum plate frame with bottom flange break-formed for attachment to U-channel and painted to match - metallic silver and dark gray. 3/8" x 1 1/4" aluminum bar mechanically fastened to backer frame using stainless steel fasteners and painted to match metallic silver. 12 1'-8" 4" 6 1/4" 22'-0" 1'-6" 1'-8 1/4" ELECTRICAL FEED: Custom fabricate aluminum raceway with weather tight access panels to support necessary transformers and painted to match - dark gray. Use GTO sleeving for power supply conduit. SECTION A LETTERS AND FRAME ASSEMBLED SIGN: Design Intent 1/2 = 1-0 FRONT VIEW 1/2 = 1-0 4'-4 3/4" EQUAL SECTIONS OF RACEWAY COVERS (removable) 12 6" 1/4" TOP VIEW 53
6 Ix-6b Building Name Detail Letters attached to backer using countersunk stainless steel fasteners 3" = 1'-0" LP4 FACE LIT LETTERS BY COLITE: White acrylic with white LED lighting embedded into acrylic 1/4" aluminum backer frame with cutout letter forms with break-formed base at 90 add gussets if necessary. Mount to U-channel using stainless steel mechanical fasteners. Drill holes for necessary access for power supply at base of letters. Custom raceway cover using 1/8 thick aluminum panel mounted to backer using L-brackets using countersunk stainless steel fasteners. 1'-6" Raceway mechanically fastened to existing canopy. Inset 2 1/2" from front edge. 1'-8 1/4" ELECTRICAL FEED: Owner is responsible for providing the electrical feed to the to sign. Fabricator to provide shop drawings showing detail of electrical location and specifications. Fabricator to provide final connection. 2" CANOPY DETAILS: TBD. Architect to supply drawings to awarded fabricator. 10" Design Intent SECTION A LOOKING SOUTH 54
7 5" 7" Sign Type Ix-7 Entrance ID, Projecting Small, Illuminated TOP VIEW 1" = 1'-0" 4" square aluminum tube and mounting plate. 1'-0" 10" 7" 5" 1'-0" 4" 10" 3'-10 1 /2" 3'-9" 3'-8" 1" Main Cabinet and Installation: Aluminum channel frame with aluminum support tubes welded to an aluminum plate. Frame skinned with 1/8" (th.) painted aluminum faces to match silver metallic. Top and bottom skins attached with counter-sunk flush screws to cover hand holes for installation. 2'-9" 2'-5 1 /2" 2'-0 3 /4" 9 3 /4" Exit Only Top and bottom rules painted to match silver metallic. 01 Face Cabinet (double-sided): 1/8" (th.) aluminum faces painted to match blue and bonded to an aluminum tube frame. Faces are fixed in place. END VIEW Signs are hard-wired, with electrical conduit to run through square aluminum tube frame into the sign cabinet. FRONT VIEW /4" 05 Copy and graphics to be push-through 1/32", 3/8" (th.) translucent white acrylic. Acrylic to be stud mounted to the back of the sign face. Illuminated using white LED's. Transfomers are to be located within the cabinet. Font: Gotham Condensed Medium Design Intent Revised For Review Patient Drop-off 6 1 /2" 9 3 /8" 1'-7" 1'-5 1 /2" 11 1 /4" P ALTERNATE LAYOUTS 1/2" = 1'-0" 55
8 5" 7" Sign Type Ix-7a Entrance ID, Projecting Small, Non-illuminated TOP VIEW 1" = 1'-0" 4" square aluminum tube and mounting plate. 1'-0" 10" 7" 5" 1'-0" 4" 10" 3'-10 1 /2" 3'-9" 3'-8" 1" Main Cabinet and Installation: Aluminum channel frame with aluminum support tubes welded to an aluminum plate. Frame skinned with 1/8" (th.) painted aluminum faces to match silver metallic. Top and bottom skins attached with counter-sunk flush screws to cover hand holes for installation. 2'-9" 2'-5 1 /2" 2'-0 3 /4" 9 3 /4" Exit Only Top and bottom rules painted to match silver metallic. 01 Face Cabinet (double-sided): 1/8" (th.) aluminum faces painted to match blue and bonded to an aluminum tube frame. Faces are fixed in place. 05 Copy and graphics to be engineer grade reflective vinyl. Font: Gotham Condensed Medium /4" END VIEW FRONT VIEW Design Intent Revised For Review Parking Elevator Patient Drop-off 6 1 /2" 9 3 /8" 1'-7" 1'-5 1 /2" 11 1 /4" P ALTERNATE LAYOUT 1/2" = 1'-0" 56
9 Ix-8 Entrance ID, Panel 1" = 1'-0" 9'-4" 1 1 /8" 1'-2 1 /2" 10" AMBULANCE ONLY 06 Side View Front View 06 1" square aluminum tube frame with an 1/8" (th.) painted aluminum face bonded to frame. Copy and graphics to be opaque vinyl. Sign is mechanically fastened to the wall. Font: Gotham Condensed Medium. Aluminum angle bracket fastened to the wall Design Intent Revised For Review Installation Detail 57
10 Light text on dark background Dark text on light background SCALE NOTE: The sign can be scaled proportionally to accommodate various installation conditions or signage codes. Ix-9 Individual Letters Illuminated Alternate background panel fabricated from 1/8" (th.) aluminum painted to match project-specific custom color (see elevation). Individual letters for building façades with dark background. Aluminum channel letters with white acrylic face and LED internal illumination. Letter returns are to be painted to match building facade or background panel color. Trim cap, if used, to be painted white. Interior of letterforms to be painted white or covered with 3M light enhancement film. Font: Gotham Condensed, Medium (or custom layout per project). 12 Individual letters for building façades with light background. Aluminum channel letters with day/night acrylic faces and LED internal illumination. Letter returns are to be painted to match building facade or background panel color. Trim cap, if used, to be painted dark gray. Interior of letterforms to be painted dark gray or covered with 3M light enhancement film. Font: Gotham Condensed, Medium (or custom layout per project)..0" thick returns See scale notes Exterior Wall Low-profile trim cap (see scale notes).0" thick returns See scale notes Exterior Wall High bond adhesive to attach acrylic face to letter return Stainless steel counter sunk screw 3/8" white acrylic face stainless steel counter sunk screw Mounting Hardware Aluminum angle support White LED lights High bond adhesive to attach acrylic face to letter return Stainless steel counter sunk screw 3/8" white acrylic face stainless steel counter sunk screw Mounting Hardware Aluminum angle support White LED lights SCALE Letter height and scale to be determined based on application and appropriate code requirements. Channel letters located on the first or second story of a building are to have 3" returns and trimless construction. Channel letters located on the third story or higher may use a low-profile trim cap. Jewel trim is not acceptable Design Intent 1/8" thick back panel 1/8" thick back panel Section Detail (trimless) Section Detail (trim cap) 58
11 Light text on dark background Dark text on light background SCALE NOTE: The sign can be scaled proportionally to accommodate various installation conditions or signage codes. Sign Type Ix-9a Individual Letters Non-Illuminated Alternate background panel fabricated from 1/8" (th.) aluminum painted to match project-specific custom color (see elevation). Letters on a dark background painted to 12 Letters on a light background painted to match White. Font: Gotham Condensed, match Dark Gray. Font: Gotham Condensed, Medium (or custom layout per project). Medium (or custom layout per project) Design Intent 1/4" (th.) painted aluminum letters. flush-mounted to painted backer panel. Attach backer panel to existing masonry structure with studs welded to reverse side of panel, secured with silicone adhesive or other per code. Side View without Panel Side View with Panel 59
12 Ix-10 Offsite Building ID (Vertical) Rabbit notch acrylic to accept aluminum returns.125" thick aluminum returns High bond adhesive to attach acrylic face to aluminum return Stainless steel counter sunk screw 1/2" = 1'-0" Stainless steel counter sunk screw Aluminum angle support 3/8" thick clear or white acrylic face White LED lights 1/8" thick back panel Section Detail Acrylic Face with Aluminum Cabinet 4'-5 3/4" 9"4 1/2" 9" 10" TOP VIEW 2 1/4" 4'-3 3/4" Two-sided, internally illuminated aluminum sign cabinet, fabricated from 1/8" (th.) material. To be illuminated with LED lighting system. 4'-2" 1 1/2" Section Detail 1 1/2" 3" 5'-4 1/2" 7'-2 1/2" 1'-3" 3" 3'-4 3/4" 11" 1 1/2" 5" Family Medicine at Gabriel Park 01 HEADER PANEL 3/8 thick acrylic sign face with mask and spray blue background with translucent white vinyl for logo symbol (see section details). Two-sided 01 BODY PANEL 1/8 thick aluminum sign face with cut-out/push-through white acrylic letters and numbers. Two-sided Design Intent Revised Review 3 1/4" 4411 SW Vermont 3" 2" All aluminum fabricated cabinet core, reveals and internal structure. Exterior surfaces painted to match brushed aluminum. 10 1'-4" 4" 1/8 thick aluminum fabricated base to have textured painted finish for a faux limestone appearance. Sign attachment, foundation and footing details to be engineered by fabricator. FRONT VIEW Electrical connection to be coordinated by fabricator. (curb side) 60
13 Ix-10 Layout Options 1/2" = 1'-0" Partner Hospital Clinic Name at Location Partner Hospital Clinic Name at Location Design Intent Revised Review 1234 Street Name 1234 Street Name 1234 Street Name OHSU CLINIC PARTNER HOSPITAL PARTNER CLINIC 61
14 Ix-10a Offsite Building ID (Horizontal) Rabbit notch acrylic to accept aluminum returns.125" thick aluminum returns High bond adhesive to attach acrylic face to aluminum return Stainless steel counter sunk screw 1/2" = 1'-0" Stainless steel counter sunk screw Aluminum angle support 3/8" thick clear or white acrylic face White LED lights 1/8" thick back panel Section Detail Acrylic Face with Aluminum Cabinet 6'-5" 6'-7 1/2" 6'-6 5/8" 4 1/2" 9" TOP VIEW 4'-8" 6'-6" 1 1/2" 1 1/2" 1'-3" 11" 5" 3 1/4" 1 1/2" 3" 2'-8" 3" 2" 1'-4" 4" 2 5/8" 2 1/4" Section Detail 6'-6 5/8" 6'-5" Family Medicine at Richmond 3930 SE Division Street Two-sided, internally illuminated aluminum sign cabinet, fabricated from 1/8" (th.) material. To be illuminated with LED lighting system. 01 HEADER PANEL 3/8 thick acrylic sign face with mask and spray blue background with translucent white vinyl for logo symbol (see section details). Two-sided 01 BODY PANEL 1/8 thick aluminum sign face with cut-out/push-through white acrylic letters and numbers. Two-sided All aluminum fabricated cabinet core, reveals and internal structure. Exterior surfaces painted to match brushed aluminum. 10 1/8 thick aluminum fabricated base to have textured painted finish for a faux limestone appearance. Sign attachment, foundation and footing details to be engineered by fabricator Design Intent Revised Review FRONT VIEW Electrical connection to be coordinated by fabricator. (curb side) 62
15 Ix-10a Layout Options 1/2" = 1'-0" Partner Hospital Clinic Name at Location Partner Hospital Clinic Name at Location Design Intent Revised Review 1234 Street Name 1234 Street Name 1234 Street Name OHSU CLINIC PARTNER HOSPITAL PARTNER CLINIC 63
16 Ix-10c Offsite Building ID Custom 1/2" = 1'-0" 6'-5" 6'-7 1/2" 6'-6 5/8" 4 1/2" 9" TOP VIEW Two-sided, internally illuminated aluminum sign cabinet, fabricated from 1/8" (th.) material. To be illuminated with LED lighting system. 6'-6 5/8" 6'-5" Break-formed corners Removable panel to access mounting bolts. Internal structure 6'-2 1/2" 1 1/2" 1'-8 3/4" 3" 2" 3" 3" 1'-4" 4" 2 1/2" 2 1/4" 2415 SE 43rd 4212 SE Division Street All aluminum fabricated cabinet core, reveals and internal structure. Exterior surfaces painted to match brushed aluminum. 01 BODY PANEL 1/8" thick aluminum sign face with masked and sprayed letters (Message on both sides). Translucent vinyl graphics 3/8" thick white acrylic face with masked and sprayed opaque graphics. 1/8" thick aluminum sign face with masked and sprayed letters (Message on both sides). Internal steel structure. Post size and cross members to be engineered by fabricator. 10 1/8" thick aluminum fabricated base to have textured painted finish for a faux limestone appearance. Sign mounting, foundation and footing details to be engineered by fabricator Design Intent Revised Branding Design Submittal Update Revised Design Revised Logo FRONT VIEW Concrete foundation depth to need of exceed local code. (curb side) Electrical connection to be coordinated by fabricator. 64
17 NOT TO SCALE Sign Type TOP VIEW SCALE NOTE: The sign can be scaled proportionally to accommodate various installation conditions or signage codes. Ix-11 Offsite Building ID (Horizontal) Section Detail NOT TO SCALE FABRICATOR TO FIELD VERIFY DIMENSIONS DO NOT EXCEED MAXIMUM SQ FT FOR ON BUILDING SIGNAGE ACCORDING TO LOCAL CODE nts 01 OHSU Clinics Internally illuminated (LED) sign cabinet with flexible fabric face and aluminum returns and back. Wall-mounted. Surface applied transparent white vinyl for OHSU logo with opaque blue background. FRONT VIEW - Layout Option 1 Partner Hospital Break-form cover Cover screw part #5195 FRONT VIEW - Layout Option 2 Partner Hospital Clinic Name Sign Comp Bleed Fascia Frame Part #2092 Front Aluminum tube support frame #10 x 1/2" stainless steel screw (every 8" 10" on center depending on size of face). Mounting hardware as required White LED lights Design Intent Review Revised FRONT VIEW - Layout Option 3 Flex Face Section Detail Side View (nts) 65
18 NOT TO SCALE SCALE NOTE: The sign can be scaled proportionally to accommodate various installation conditions or signage codes. Ix-11a Offsite Building ID (Vertical) TOP VIEW NOT TO SCALE FABRICATOR TO FIELD VERIFY DIMENSIONS DO NOT EXCEED MAXIMUM SQ FT FOR ON BUILDING SIGNAGE ACCORDING TO LOCAL CODE Section Detail 01 OHSU Clinics Internally illuminated (LED) sign cabinet with flexible fabric face and aluminum returns and back. Wall-mounted. Surface applied transparent white vinyl for OHSU logo and text with opaque blue backround. Partner Hospital FRONT VIEW - Layout Option1 FRONT VIEW - Layout Option 2 Break-form cover Cover screw part #5195 Partner Hospital Sign Comp Bleed Fascia Frame Part #2092 #10 x 1/2" stainless steel screw (every 8" 10" on center depending on size of face) Design Intent Clinic Name Front Aluminum tube support frame Mounting hardware as required White LED lights FRONT VIEW - Layout Option 3 Flex Face Section Detail Side View (nts) 66
19 Ix-12a Retrofit Aluminum Panel, Illuminated Cut-out/Push-through copy Ix-12b Retrofit Acrylic Panel, Illuminated Translucent Sign dimensions are location specific. See annotated layouts for approximate sizes. Fabricator to field verify before creating shop drawings. SCALE NOTE: The sign can be scaled proportionally to accommodate various installation conditions or signage codes. Ix-12a,b,c,d Retrofit Panels RETROFIT: Replace existing aluminum panel with cut-out push-through acrylic messaging/graphics to match specified annotated sign layout. RETROFIT: Replace existing panel with new acrylic panel to match specified annotated sign layout. OHSU Clinics 01 Individual message panels fabricated from 1/8 (th.) aluminum and internal structure as required to fit existing sign. OHSU Clinics 01 Acrylic panel painted to match blue. OHSU Clinics Push through acrylic messsaging to match white. Font: Gotham Condensed Medium. Messaging knocked out of painted background. Font: Gotham Condensed Medium. Push through acrylic logo to match white. Logo knocked out of painted background. OHSU Clinics Ix-12c Retrofit Aluminum Panel, Non-illuminated Reflective Ix-12d Retrofit Aluminum Panel, Non-illuminated Mask and Spray Partner Hospital RETROFIT: Replace existing sign panel with new painted aluminum panel and reflective graphics to match specified annotated sign layout. OHSU Clinics 01 Individual painted message panels fabricated from 1/8 (th.) acrylic and internal structure as requied to fit existing sign. RETROFIT: Replace existing sign panel with new painted aluminum panel and mask-and-spray graphics to match specified annotated sign layout. OHSU Clinics 01 Individual painted message panel fabricated from 1/8 (th.) aluminum and internal structure as required to fit existing sign. Partner Hospital Messaging to be surface applied reflective vinyl to match white. Font: Gotham Condensed Medium. Logo to be surface applied reflective vinyl to match white. Messaging to be mask-and-spray painted to match white. Font: Gotham Condensed Medium. Logo to be mask-and-spray painted to match white. Applied vinyl divder rule line Partner Hospital Clinic Name Design Intent Branding Revised Update Revised Partner Hospital Clinic Name Layouts: 67
20 Kx-1 Pedestrian Map Kiosk 1/2" = 1'-0" 1 1/4" 4" TOP VIEW BACK VIEW 3/16" high pressure laminate panel map panel mechanically mounted to sign cabinet with tamper-resistent stainless steel screws. 2" 8" 1" 3'-8 1/8" /2" 5" 3" 1 1/2" eq 3'-3 3/4" 2'-8 1/2" 2 1/8" 2'-1" 02 3'-6 1/4" INFORMATION 1/2" 6" '-10" Fabricated aluminum panel constructed to support sign cabinet. Tapered post cap 01 Fabricated aluminum cabinet. Fabricator to field verify all mounting conditions and determine final mounting hardware. Masked and sprayed graphics Design Intent 1 1/2" 3" square steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals. Internal steel bracket bolted to footing. External aluminum sleeve secured with counter-sunk screws painted to match post. 2'-0" 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals. FRONT VIEW Galvanized or stainless steel "J" Anchor Bolts Internal steel post bolted to footing. External aluminum sleeve secured with counter-sunk screws painted to match post. Concrete foundation cylinder FOUNDATION AND MOUNTING TO BE ENGINEERED BY FABRICATOR 68
21 Kx-2 Pedestrian Map, Small Wall Mounted 1/2" = 1'-0" TOP VIEW 3'-1/2" 3/16" high pressure laminate panel map panel mechanically mounted to sign cabinet with tamper-resistent stainless steel screws. 2" 8" 1" 3'-8 1/8" /2" 5" 3" 1 1/2" eq 3'-4" 2'-8 1/2" 2 1/8" 2'-1" 02 INFORMATION '-10" 3" 2" 01 Fabricated aluminum cabinet. Fabricator to field verify all wall conditions and determine final mounting hardware. Masked and sprayed graphics. Fabricated aluminum cabinet. Painted band and return edges. 01 Painted band and return edges with surface applied reflective vinyl copy Design Intent 1 1/2" eq FRONT VIEW Approximately 2'-0" above grade WALL MOUNTING BRACKETS AND/OR HARDWARE TO BE ENGINEERED BY FABRICATOR 69
22 Fire Hydrant H2 TYP. Q4 TYP. P1 TYP. C1 TYP. P3 TYP. Q2 TYP. H1 TYP. B2 TYP. K1 TYP. K3 TYP. H2 TYP. Q4 TYP. P1 TYP. C1 TYP. P3 TYP. Q2 TYP. H1 TYP. B2 TYP. K1 TYP. Kx-3 Parking Kiosk Options Manholes B1 B1 1/2" = 1'-0" Can we reduce the size of the planter box to accommodate space for the Parking Kiosk? Proposed Parking Kiosk location Tram Track/Right Turn sign Q1 Q1 Light Pole Utility Vault TYP. B1 TYP. B1 TYP. K3 TYP. K3 EXISTING PLAN RECOMMENDED PLAN 2'-8 1/2" TYP. Q1 3'-1 1/8" TYP. Q1 OPTION 1 OPTION 2 10" TYP. P1 TYP. P1 10" TOP VIEW TYP. C1 TYP. C1 TOP VIEW TYP. P3 TYP. P3 10" 3" Fabricated aluminum panel constructed to support sign cabinet. 05 Fabricated aluminum cabinet. Fabricator to field verify all mounting conditions and determine final mounting hardware. Masked and sprayed graphics. Messaging is cutout, pushed-through flush white translucent acrylic copy and parking symbol circles. Monochrome electronic LED message boards (one on each face) mounted within sign cabinet. Product specifications TBD /8" 05 TYP. Q7 2'-11" 2'-8 5/8" CHH Garage OPEN FULL Rood Family Garage P OPEN FULL P GVLT B1 TYP. 88 T 92 4'-10" P1 TYP. Q2 TYP. B1 TYP. Q2 10" TYP. Q7 05 GVLT Fabricated aluminum cabinet. Fabricator to field verify all mounting conditions and determine final mounting hardware. Masked and sprayed graphics. B1 TYP. T Messaging is cutout, pushed-through flush white translucent acrylic P1 TYP. copy and parking symbol circles. Monochrome electronic LED message boards (one on each face) mounted within sign cabinet. Product specifications TBD. Q2 TYP. 2'-2 1/8" 2'-2 1/8" 05 2'-8 1/2" CHH Garage OPEN FULL Rood Family Garage P OPEN FULL P 4'-5 3/16" Design Intent 4" steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals. 2'-0" 4" steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals. 2'-1 1/2" Internal steel bracket bolted to footing. External aluminum sleeve secured with counter-sunk screws painted to match post. Internal steel bracket bolted to footing. External aluminum sleeve secured with counter-sunk screws painted to match post. 4" FRONT VIEW 4" FRONT VIEW Galvanized or stainless steel "J" Anchor Bolts Galvanized or stainless steel "J" Anchor Bolts Concrete foundation cylinder FOUNDATION AND MOUNTING TO BE ENGINEERED BY FABRICATOR Concrete foundation cylinder 70
23 Nx-1 NOTICE PLAQUE : 1 1/2 = 1-0 on an 11 x 17 sheet Sign Type Nx-1 Notice Plaque 1'-0" 1'-0" Loading Dock 1'-0" Authorized Personnel Only See Front Security Desk for Entry 1'-0" 8:00am - 4:30pm For assistance please call For after hours assistance please call /2" 1 5/8" 5/8" 1 1/8" 5 1/2" Authorized Personnel Only 1 5/8" See Front Security Desk for Entry 1 5/8" FONT: Gotham Condensed, 10% kerning SMALL FONT: Gotham Condensed, 5% kerning 1 5/8" 1 5/8" 2" Loading Dock 8:00am - 4:30pm For assistance please call /8" 3/4" For after hours assistance please call /8" FONT: Gotham Condensed, 0% kerning SMALL FONT: Gotham Condensed, 5% kerning Nx-1 NOTICE PLAQUE : 1/2 = 1-0 on an 11 x 17 sheet 1'-0" TOP VIEW 1'-0" Authorized Personnel Only See Front Security Desk for Entry For after hours assistance please call '-0" TOP VIEW 1'-0" Loading Dock 8:00am - 4:30pm For assistance please call For after hours assistance please call NOTICE PLAQUE: 1/8 Painted aluminum plaque with silk-screened copy and graphics Design ReviewIntent 71
24 Px-1 Garage ID Freestanding, Large Non-Illuminated 1/2" = 1'-0" 1 1/4" 4" TOP VIEW 2 1/2" 3'-2" 3'-9 1/2" 1/2" 6" Fabricated aluminum panel constructed to support sign cabinet. Surface applied reflective vinyl " Tapered post cap 1'-6" 11" D 6 1/2" Masked and sprayed background field and white border with gold reflective graphics. DOUBLE-SIDED Fabricated aluminum cabinet. 1" 1 1/2" 4 3/4" 2" 1 1/2" 3 5/8" 3 5/8" 2'-8" 3 5/8" 3 5/8" 3 5/8" Patients and Visitors park here for: Hatfield Research Ctr OHSU Hospital Sam Jackson Hall 5" 4'-5 1/2" 1 1/4" 6'-10 1/2" 01 Painted band and return edges with surface applied reflective vinyl copy. Snap frame extrusion to allow message panel to be changed. REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue with surface applied reflective vinyl graphics. 05 P Visitor Parking 1'-11" Design Intent THIS SIDE IS ALWAYS CLOSEST TO ROAD /2" Recess filled to grade with grey colored gravel. 2'-6" 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals. Metal landscaping trim ring with drain holes. FRONT VIEW Galvanized or stainless steel "J" Anchor Bolts Concrete foundation cylinder FOUNDATION AND MOUNTING TO BE ENGINEERED BY FABRICATOR 72
25 Px-1a Garage ID Freestanding, Large Illuminated 1/2" = 1'-0" 1 1/4" 4" TOP VIEW DATA SOURCE NOTE Owner to provide hardwire data connection at sign location. Cut-out, pushed-through flush white translucent acrylic circle with surface applied translucent graphic. 05 1'-6" 11" 1" 1 1/2" 2" 1 1/2" 3 5/8" 1 3/4" 3 5/8" 2'-8" 3 5/8" 3 5/8" 2 1/2" 88 3'-2" D 3'-9 1/2" Park here for: Doernbecher Children s Hospital OHSU Hospital FULL OPEN 2 3/4" 6 1/2" 1/2" 6" /4" 5" ALTERNATE DATA SOURCE Wireless data connection module incorporated into sign cabinet. 3" 4'-5 1/2" 1 1/4" 6'-10 1/2" Custom LED symbol. Black when not illuminated. Red LED X when illuminated. Cut-out, pushed-through flush white translucent acrylic panel with surface applied translucent graphic. Fabricated aluminum panel constructed to support sign cabinet. Tapered post cap 01 DOUBLE-SIDED INTERNALLY ILLUMINATED Fabricated aluminum cabinet. White LEDs to back light 12" circle and triple diamond symbol. Painted band and return edges with surface applied reflective vinyl copy. 11 Painted band and return edges Quantity 2 (one for each side) 7"H x 18"W x 2.5"deep commercially available TCL LED direct-view display. OPEN (green) FULL (red) REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue with surface applied reflective vinyl graphics. 05 P Visitor Parking 1'-11" Snap frame extrusion to allow message panel to be changed Design Intent THIS SIDE IS ALWAYS CLOSEST TO ROAD /2" Recess filled to grade with grey colored gravel. 2'-6" 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals. Metal landscaping trim ring with drain holes. FRONT VIEW Galvanized or stainless steel "J" Anchor Bolts Electrical/data connection to be coordinated by fabricator and owner representative. Concrete foundation cylinder FOUNDATION AND MOUNTING TO BE ENGINEERED BY FABRICATOR 73
26 Px-1b Garage ID Freestanding, Large Illuminated w/ Display 1/2" = 1'-0" 10" 1 1/4" 4" TOP VIEW Cut-out, pushed-through flush white translucent acrylic circle with surface applied translucent graphic. 05 Double-sided 19"H x 34"W x 10" deep (5" deep each) Daktronics AF mm pixel amber LED displays. THIS SIDE IS ALWAYS CLOSEST TO ROAD 6" wide x 4" deep fabricated aluminum support leg with 3" internal steel post. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals. 1'-6" 11" Metal landscaping trim ring with drain holes. 1" 1 1/2" 2" 1 1/2" 3 5/8" 1 3/4" 3 5/8" 2'-8" 3 5/8" 3 5/8" 2 1/2" 88 3'-2" D 3'-9 1/2" Park here for: Doernbecher Children s Hospital OHSU Hospital FULL OPEN Datronics AF-3200 Recess filled to grade with grey colored gravel. 6 1/2" 1/2" 6" DATA SOURCE NOTE Owner to provide hardwire data connection at sign location. ALTERNATE DATA SOURCE Wireless data connection module incorporated into sign cabinet. 3" 4'-5 1/2" 1 1/4" 1'-11" /2" 3" 92 3" 5" 6'-10 1/2" 2'-6" Custom LED symbol. Black when not illuminated. Red LED X when illuminated. Cut-out, pushed-through flush white translucent acrylic panel with surface applied translucent graphic. Fabricated aluminum panel constructed to support sign cabinet. Tapered post cap 01 DOUBLE-SIDED INTERNALLY ILLUMINATED Fabricated aluminum cabinet. White LEDs to back light 12" circle and triple diamond symbol. Painted band and return edges with surface applied reflective vinyl copy. 11 Painted band and return edges Quantity 2 (one for each side) 7"H x 18"W x 2.5"deep commercially available TCL LED direct-view display. OPEN (green) FULL (red) 11 Fabricated aluminum cabinet. 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals Design Intent FRONT VIEW Galvanized or stainless steel "J" Anchor Bolts Electrical/data connection to be coordinated by fabricator and owner representative. Concrete foundation cylinder FOUNDATION AND MOUNTING TO BE ENGINEERED BY FABRICATOR 74
27 4" 1 1/4" TOP VIEW Px-2 Garage ID Projecting Illuminated Flexface cabinet Translucent graphics /2" 88 3'-5" 3'-2" 1/2" 3" 3" Fabricated aluminum panel constructed to support sign cabinet. Tapered post cap 1/2" = 1'-0" 1'-6" 11" 1" 1 1/2" 5 3/8" 2" 1 1/2" 3 5/8" 1 3/4" 2'-8" 3 5/8" 3 5/8" 3 5/8" D Park here for: Doernbecher Children s Hospital OHSU Hospital 6 1/2" 5" 4'-5 1/2" 1 1/4" 6'-10 1/2" Translucent graphics MOUNTING BRACKET AND ANY ADDITIONAL STRUCTURAL SUPPORT WITHIN THE WALL TO BE ENGINEERED BY FABRICATOR DOUBLE-SIDED INTERNALLY ILLUMINATED Fabricated cabinet with white LEDs. Panaflex faces for upper cabinet with opaque background and internally illuminated letters and graphics. 01 Painted band and return edges with translucent white copy. Snap frame extrusion to allow message panel to be changed. REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue with surface applied reflective vinyl graphics. 05 P Visitor Parking 1'-11" 6" half round aluminum post. 92 FRONT VIEW 1 1/2" DOUBLE-SIDED Fabricated aluminum cabinet. Final height to be determined Design Intent FRONT VIEW 75
28 Flexface cabinet 10" illuminated circle with surface 05 applied translucent graphic. 4" 1 1/4" 1'-6" 11" 1" 1 1/2" 2" 1 1/2" 3 5/8" 1 3/4" 3 5/8" 2'-8" 3 5/8" 3 5/8" TOP VIEW D Park here for: Doernbecher Children s Hospital OHSU Hospital FULL OPEN 3" 6 1/2" 3" 5" DATA SOURCE NOTE Owner to provide hardwire data connection at sign location. ALTERNATE DATA SOURCE 3'-5" 1/2" Wireless data connection module Fabricated aluminum panel 3'-2" 3" incorporated into sign cabinet. constructed to support sign 2 1/2" cabinet Tapered post cap 3" 4'-5 1/2" 1 1/4" 6'-10 1/2" Surface applied translucent graphic. Custom LED symbol. Black when not illuminated. Red LED X when illuminated. DOUBLE-SIDED INTERNALLY ILLUMINATED Fabricated cabinet with white LEDs. Panaflex faces for upper cabinet with opaque background and internally illuminated letters and graphics. 01 Painted band and return edges with translucent white letters 6" half round aluminum post. Quantity 2 (one for each side) 7"H x 18"W x 2.5"deep commercially available TCL LED direct-view display. OPEN (green) FULL (red) D Park here for: Doernbecher Children s Hospital OHSU Hospital FULL OPEN 6 1/2" 92 Px-2b/Px-2c Garage ID, Electronic Projecting/Wall Mounted 1/2" = 1'-0" Fabricated aluminum cabinet Double-sided 19"H x 34"W x 10" deep (5" deep each) Daktronics AF mm pixel amber LED displays. Datronics AF '-11" Fabricated aluminum cabinet Datronics AF /2" Px-2c is a single side wall mounted verison of the Px-2b. MOUNTING BRACKET AND ANY ADDITIONAL STRUCTURAL SUPPORT WITHIN THE WALL TO BE ENGINEERED BY FABRICATOR Electrical connection to be coordinated by fabricator and owner representative. Final height to be determined Design Intent Px-2b FRONT VIEW Px-2b Px-2c FRONT VIEW 76
29 TOP VIEW Px-2d Garage ID Wall Mounted Non-Illuminated 3'-5" Flexface cabinet Reflective graphics 05 1'-6" 11" 2 1/2" 88 3'-2" D 3 1/2" 3" 4" 2" Fabricated aluminum cabinet. Fabricator to field verify all wall conditions and determine final mounting hardware. 1/2" = 1'-0" 1" 1 1/2" 5 3/8" 2" 1 1/2" 3 5/8" 1 3/4" 2'-8" 3 5/8" 3 5/8" 3 5/8" Park here for: Doernbecher Children s Hospital OHSU Hospital 4'-5 1/2" 6'-10 1/2" 01 Painted band and return edges with surface applied reflective vinyl copy. 1 1/4" Snap frame extrusion to allow message panel to be changed. REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue with surface applied reflective vinyl graphics. 05 P Visitor Parking 1'-11" 92 FRONT VIEW 1 1/2" MOUNTING BRACKET AND ANY ADDITIONAL STRUCTURAL SUPPORT WITHIN THE WALL TO BE ENGINEERED BY FABRICATOR Final height to be determined Design Intent Revised 77
30 1'-6" 1/2" Sign Type Px-2e Garage ID, Projecting, Small, Illuminated TOP VIEW 1" = 1'-0" 7" 5" 3'-10 1 /4" 3'-9 1 /2" Main Cabinet and Installation: Aluminum channel frame skinned with 1/8" (th.) painted aluminum faces to match silver metallic. Cabinet is mounted flush to the wall. Awarded fabricator to engineer the mounting details. Architect to provide wall cross-sections drawings to awarded fabricator. 1'-7" 1'-3 1 /2" END VIEW 3'-1 1 /2" 1'-7" 1'-4" 4 1 /2" 1'-3 1 /2" 1'-3" 6" 2 1 /2" P OPEN FULL Rood Family Pavilion Signs are hard-wired, with electrical conduit to run into the sign cabinet. FRONT VIEW Quantity 2 (one for each side) 7"H x 18"W x 2.5"deep commercially available TCL LED direct-view display. OPEN (green) FULL (red). Displays may sit proud of face up to 1", prefer 1/2". Upper Face Cabinet (double-sided): 1/8" (th.) aluminum faces painted to match blue and bonded to an aluminum tube frame. Faces are fixed in place. Parking symbol to be push-through 1/32", 3/8" (th.) translucent white acrylic with translucent blue vinyl on first surface. Acrylic to be stud mounted to the back of the sign face. Illuminated using white LED's. Transfomers are to be located within the cabinet. Lower Face Cabinet (double-sided): Removable 1/8" (th.) aluminum panels installed into a thin retainer system. Painted to match blue (panels and retainers). Retainers on side of sign to be easily removed for access to insert panels. Copy to be push-through 1/32", 3/8" (th.) translucent white acrylic. Acrylic to be stud mounted to the back of the aluminum insert panel. Illuminated using white LED's. Transfomers are to be located within the cabinet. Font: Gotham Condensed Medium Design Intent Revised For Review P OPEN FULL Center for Health & Healing ALTERNATE LAYOUT 1/2" = 1'-0" 78
31 Px-3 Garage ID Bulkhead Mounted Electrical connection to be coordinated by fabricator and owner representative. 1/2" = 1'-0" TOP VIEW 6'-7" 6'-3 1/2" eq 88 1'-6" 1'-0" 1" eq 2 1/8" 88 A FRONT VIEW 6" 2 1/2" 2 1/8" 3 5/8" 4 1/2" Flexface cabinet Park here for: Emma Jones Hall 4" 92 2'-3" 1'-9 1/2" 1 1/2" 4" 2" Fabricated aluminum cabinet to form background element. INTERNALLY ILLUMINATED Fabricated cabinet with white LEDs. Panaflex faces with opaque background and internally illuminated letters and graphics. 05 translucent circle with surface applied translucent graphic Design Intent Branding Revised Update WALL MOUNTING BRACKETS AND/OR HARDWARE TO BE ENGINEERED BY FABRICATOR 79
32 C 9" 3 5/8" 4 1/2" Permit Parking Only Sign Type Px-3a Garage ID Wall Mounted, Custom Curve 1/2" = 1'-0" ALTERNATE LAYOUT Masked and sprayed background field and white border with gold reflective graphics. CUSTOM CURVED PANEL REQUIRED. FABRICATOR TO FIELD VERIFY CURVE DIMENSIONS. TOP VIEW 6'-3 1/2" eq 88 1'-6" 1'-0" 1" eq 2 1/8" 88 C 01 Masked and sprayed graphics Patients and Visitors Park here for: OHSU Hospital and Sam Jackson Hall 3 5/8" 3 3/4" 2 7/8" 2 5/8" 1 3/4" 2 5/8" 1'-9 1/2" 01 1/8 thick painted aluminum panel Design RevisedIntent FRONT VIEW 05 Surface applied white reflective circle with translucent parking blue field with cut out letter. Surface applied white reflective graphics. MOUNTING TO BE ENGINEERED BY FABRICATOR 80
33 Px-4 Garage ID Freestanding, Small 1/2" = 1'-0" A Park here for: Emma Jones Hall 1 1/4" 4" P Visitor Parking TOP VIEW BACK VIEW Surface applied reflective vinyl /2" 3'-2" 3'-9 1/2" 88 1/2" 6" 3" Fabricated aluminum panel constructed to support sign cabinet. Tapered post cap REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue with surface applied reflective vinyl graphics. THIS SIDE IS ALWAYS CLOSEST TO ROAD 05 3" square steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals. 1'-6" 1'-0" 1" 2" 3 3/4" 2" 1 1/2" 1'-3 1/2" 3" A Park here for: Emma Jones Hall P Visitor Parking Recess filled to grade with grey colored gravel. Metal landscaping trim ring with drain holes. 6 1/2" 92 3'-1" 1 1/4" 1'-11" /2" 5" 5'-6" 1'-10" Masked and sprayed background field and white border with gold reflective graphics. DOUBLE-SIDED Fabricated aluminum cabinet. 01 Painted band and return edges with surface applied reflective vinyl copy. Snap frame extrusion to allow message panel to be changed. 6" round steel post. Wall thickness to be determined by fabricator. Post painted with epoxy primer to prevent galvanic reaction between dissimilar metals Design Intent FRONT VIEW Galvanized or stainless steel "J" Anchor Bolts Concrete foundation cylinder FOUNDATION AND MOUNTING TO BE ENGINEERED BY FABRICATOR 81
34 Px-5 Staff Lot ID Freestanding 1/2" = 1'-0" TOP VIEW 1/8" thick aluminum plate BACK VIEW REMOVEABLE 1/8" thick Sintra (PVC board) painted parking blue with surface applied reflective vinyl graphics /8" 7/8" 2 1/2" 1'-2 1/2" 8 3/8" 2'-2" 10 Staff Parking 12 3'-3" 5 1/8" 4" 1 3/4" 1'-8" Reflective vinyl graphics Snap frame extrusion to allow message panel to be changed Design Intent Reflective vinyl graphics 3" square aluminum post. Wall thickness to be determined by fabricator. 2'-6 1/2" FRONT VIEW Concrete foundation cylinder FOUNDATION AND MOUNTING TO BE ENGINEERED BY FABRICATOR 82
35 Px-6/Px-6a Garage Entrance ID Wall Mounted 8'-0" 3/4" = 1'-0" 1'-4 3/4" EXIT ONLY Px-6a GARAGE EXIT IDENTIFI- ER, WALL-MOUNTED, ILLUMI- NATED Painted aluminum sign cabinet with cut-out push-through white acrylic circle and applied red translucent vinyl. 8'-0" 1'-4 3/4" P ENTRANCE P Px-6 GARAGE ENTRANCE IDENTIFIER, WALL-MOUNTED, ILLUMINATED Painted aluminum sign cabinet with cut-out push-through white acrylic letters. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps. 0'-0" Clearance Design ReviewIntent Px-6d Garage Clearance Bar 83
36 1'-6" 1'-0" 9" 1'-6" P 7" 4" 8'-6" ENTRANCE??'-??" Clearance 5'-6" TBD, based on clearance height. P INSTALLATION: 2 1/4" sq. aluminum tube with welded mounting plate mechanically fastened to building. Engineering to be provided by awarded fabricator. Electrical feed to run through one of the support tubes Signs are hard-wired, with electrical conduit to run through square aluminum tube frame into the sign cabinet. SIGN CABINET: Internally-illumined, double-sided painted aluminum cabinet fabricated from 1/8" (th) aluminum. Copy and graphics to be push-through 1/32", 3/8" (th.) translucent white acrylic. Acrylic to be stud mounted to the back of the sign face. Illuminated using white LED's. Transfomers are to be located within the cabinet. Center copy vertically on sign face and horizontally between parking symbols. Font: Gotham Condensed Medium 00 CLEARANCE PANEL AND CHAINS: 11 Painted aluminum cabinet with mask and spray graphics. Chain height and number to be coordinated with parking consultant. Font: Gotham Condensed Medium 6" 2 1 /4" Sign Type Px-6b Garage Entrance ID Clearance Bar, Illuminated Double-sided 1" = 1'-0" FRONT VIEW 4" 6" NOT AN EXIT Design Intent Revised For Review BACK VIEW 84
37 Px-6c Garage Exit ID Illuminated, Double-sided Signs are hard-wired, with electrical conduit to run through square aluminum tube frame into the sign cabinet. 6" 2 1 /4" 1" = 1'-0" 1'-6" 8'-6" TBD, based on clearance height. INSTALLATION: 2 1/4" sq. aluminum tube with welded mounting plate mechanically fastened to building. Engineering to be provided by awarded fabricator. Electrical feed to run through one of the support tubes. 1'-6" 1'-0" 9" EXIT ONLY SIGN CABINET: Internally-illumined, double-sided painted aluminum cabinet fabricated from 1/8" (th) aluminum. Copy and graphics to be push-through 1/32", 3/8" (th.) translucent white acrylic. Acrylic to be stud mounted to the back of the sign face. Illuminated using white LED's. Transfomers are to be located within the cabinet. Center copy vertically on sign face and horizontally between parking symbols. Font: Gotham Condensed Medium FRONT VIEW 6" 3" 3" 8'-6" 1'-6" 9" LEFT TURN ONLY Design Intent Revised For Review BACK VIEW 85
38 Px-6d Garage Clearance Bar 1" = 1'-0" 9'-1" 7" 7'-0" Clearance 8'-2" Accessible Clearance CLEARANCE PANEL AND CHAINS: Painted aluminum cabinet with mask and spray graphics. Chain height and number to be coordinated with parking consultant. Font: Gotham Condensed Medium. Fabricator to engineer attachment. 4" FRONT VIEW 7" 9'-1" 7'-0" Clearance CLEARANCE PANEL AND CHAINS: Painted aluminum cabinet with mask and spray graphics. Chain height and number to be coordinated with parking consultant. Font: Gotham Condensed Medium. Sign to be attached to entrance drive portal. Portal design to be prepared by SRG and will extend over the drive aisle. Fabricator to engineer attachment of clearance bar to entrance drive portal sign Design Intent 4" FRONT VIEW 86
39 Px-6e GARAGE ENTRANCE ID w/ CLEARANCE BAR : 1/2 = 1-0 on an 11 x 17 sheet Px-6f GARAGE EXIT IDENTIFIER : 1/2 = 1-0 on an 11 x 17 sheet Sign Type Px-6e/Px-6f Garage Entrance/Exit ID Distance to be determined 13'-7" 6" by Owner 2'-3" 9'-1" 6" 2'-4" 10'-0" 5'-4" 1/2" = 1'-0" 1'-6" 1'-2" P Parking Entrance 8 1/2" P 1'-6" 1'-2" 8 1/2" Exit Only 2'-3" 4" 7'-0" Clearance 8'-2" Accessible Clearance 2'-3" 2'-4" 2'-4" 4" Distance to be determined by Owner SIGN CABINET: Painted aluminum cabinet with cut-out pushed-through white acrylic letters and circle P symbol. Center copy vertically on sign face and horizontally between parking symbols. SYMBOLS: Cut-out pushed-through white acrylic with blue translucent vinyl. SIGN CABINET FONT: Gotham Condensed, Medium. Optical kerning 50% CLEARANCE BAR FONT: Gotham Condensed, Medium. Optical kerning 25% CLEARANCE CHAINS: To be coordinated with parking consultant. SIGN CABINET: Painted aluminum cabinet with cut-out pushed-through white acrylic letters. Center copy vertically on sign face and horizontally between do not enter symbols. MOUNTING: Mounting height to be determined on site. Owner to verify clearance. FONT: Gotham Condensed, Medium. Optical kerning 50% SYMBOLS: Cut-out pushed-through white acrylic circle and dash with surface applied red translucent vinyl. MOUNTING: Mounting height to be determined on site. Owner to verify clearance. BACK VIEW 1'-2" 1'-6" 8 1/2" 13'-7" NOT AN EXIT BACK VIEW 1'-6" 9 1/4" 11 3/8" 10'-0" Left Turn Only 8 3/8" Design ReviewIntent 2'-3" 2'-3" SIGN CABINET FONT: Gotham Condensed, Medium. Optical kerning 50% ALL CAPITAL LETTERS. 87
40 8'-0" Sign Type Px-7 Garage Entrance ID Wall Mounted 1'-4 3/4" EXIT ONLY 3/4" = 1'-0" E X I T O N LY ENTRANCE 0'-0" Clearance Px-7a GARAGE EXIT IDENTIFIER, WALL-MOUNTED, NON-ILLUMINATED Painted aluminum sign cabinet with reflective vinyl letters and graphics. 8'-0" 1'-4 3/4" ENTRANCE RENDERING OF LOCATION 1 E X I T O N LY ENTRANCE 0'-0" Clearance 0'-0" Clearance Px-7 GARAGE ENTRANCE IDENTIFIER, WALL-MOUNTED, NON-ILLUMINATED Painted aluminum sign cabinet with reflective vinyl letters and graphics. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps. RENDERING OF LOCATION 2 CUSTOM MOUNTING CONDITIONS Clean and repaint existing overhead steel structure OHSU parking blue. Mount Px-7 and Px7a to horizontal cross member Design ReviewIntent 88
41 Px-8/8a/8.2 Overhead Guide, Long 5'-6" 3/4" = 1'-0" 1'-0" Parking 6 1/2" Px-8 Suspended Painted 1/8 aluminum panel with reflective vinyl letters and graphics. 9 1/8" 2'-1" FONT: Gotham Condensed Medium kerning set at 50%. Aluminum frame is mechanically fastened to ceiling. NOTE: Fabricator to verify ceiling heights prior to construction to maintain posted clearance height and determine frame tube lengths. Px-8.2 Suspended, double-sided Painted 1/8 aluminum panel with reflective vinyl letters and graphics Design Intent 1'-0" 5'-6" Parking 6 1/2" Px-8a Beam Mounted Painted 1/8 aluminum panel with reflective vinyl letters and graphics. FONT: Gotham Condensed Medium kerning set at 25%. 89
42 ALTERNATE LAYOUTS Px-8/8a/8.2 Layout Options 3" Express Lane Credit Cards, Permits, Validations 3 1/4" 1'-5" Park Exit Level P6 Layouts for parking levels 2" 1" 4 1/2" Level P1 Level P6 3/4" = 1'-0" 1'-5 5/8" 2'-8" 2'-1" Elevators Valet Pickup 1" 5 3/8" 3 1/4" Parking Exit 5'-6" Right Turn Only 3" Level P3 Patient & Patient Visitor Parking 3 1/4" 1'-1 1/4" P2 Level P2 Guest House Parking Only P5 Level P5 Permit Parking Only Design Intent 1'-5 5/8" 2'-8" 1'-5 5/8" 2'-8" Exit/ Parking Badge Access Only 1" 5 3/8" 3 1/4" Exit Right Turn Only 1" 5 3/8" 3 1/4" 90
43 Px-8b/8c/8b.2 Overhead Guide, Long 3/4" = 1'-0" 4'-7" 10" 7 5/8" 1'-8 3/4" Parking 5 1/2" Px-8b Suspended Painted 1/8 aluminum panel with reflective vinyl letters and graphics. FONT: Gotham Condensed Medium kerning set at 50%. Aluminum frame is mechanically fastened to ceiling. NOTE: Fabricator to verify ceiling heights prior to construction to maintain posted clearance height and determine frame tube lengths. Px-8b.2 Suspended, double-sided Painted 1/8 aluminum panel with reflective vinyl letters and graphics. 10" 4'-7" Right Turn Only 11" Px-8c Beam Mounted Painted 1/8 aluminum panel with reflective vinyl letters and graphics Design Intent Aluminum frame is mechanically fastened to ceiling through 4" layer of insulation. 91
44 Px-9/9a/9.2 Overhead Guide, Short 3/4" = 1'-0" 1'-0" 1'-0" 6 1/2" 4'-7" Parking Px-9 Suspended Painted 1/8 aluminum panel with reflective vinyl letters and graphics. 9 1/8" FONT: Gotham Condensed Medium kerning set at 50%. Aluminum frame is mechanically fastened to ceiling. NOTE: Fabricator to verify ceiling heights prior to construction to maintain posted clearance height and determine frame tube lengths. 1'-0" 4'-7" Parking Px-9a Beam Mounted Painted 1/8 aluminum panel with reflective vinyl letters and graphics. Px-9.2 Suspended, double-sided Painted 1/8 aluminum panel with reflective vinyl letters and graphics. ALTERNATE LAYOUTS Design Intent Exit No Exit 92
45 Px-9b/9c/9b.2 Overhead Guide, Short 3/4" = 1'-0" 10" 10" 3'-10" Parking 5 1/2" Px-9b Suspended Painted 1/8 aluminum panel with reflective vinyl letters and graphics. FONT: Gotham Condensed Medium kerning set at 50%. 7 5/8" Px-9b.2 Suspended, double-sided Painted 1/8 aluminum panel with reflective vinyl letters and graphics. Aluminum frame is mechanically fastened to ceiling. NOTE: Fabricator to verify ceiling heights prior to construction to maintain posted clearance height and determine frame tube lengths. 10" 3'-10" Exit Design Intent Px-9c Beam Mounted Painted 1/8 aluminum panel with reflective vinyl letters and graphics. ALTERNATE LAYOUTS No Exit Aluminum frame is mechanically fastened to ceiling through 4" layer of insulation. 93
46 Px-10, Px-10a Overhead Two Way Traffic Long 1'-0" 9 3/8" 1'-2 3/4" 4 5/8" 4'-7" Two-way Traffic Px-10 OVERHEAD TWO WAY TRAFFIC, SUSPENDED Painted 1/8 aluminum panel with black reflective vinyl letters and graphics. FONT: Gotham Condensed Medium kerning set at 25%. 3/4" = 1'-0" Two-way Traffic Back-view Design Intent 1'-0" 4'-7" Two-way Traffic Px-10a OVERHEAD TWO WAY TRAFFIC, BEAM MOUNTED Painted 1/8 aluminum panel with black reflective vinyl letters and graphics. 94
47 Px-11 OVERHEAD CLEARANCE, SUSPENDED Painted 1/8 aluminum panel with black reflective vinyl letters and graphics. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps. Px-11, Px-11a Overhead Clearance Suspended/Beam Mounted 3/4" = 1'-0" 4'-7" 1'-0" 4" Caution: Clearance Change 0'-0" Clearance Aluminum frame is mechanically fastened to ceiling. Px-11a OVERHEAD CLEARANCE, BEAM MOUNTED Painted 1/8 aluminum panel with black reflective vinyl letters and graphics. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps. 1'-0" 4'-7" Caution: Clearance Change Design ReviewIntent 0'-0" Clearance 95
48 Px-11b Overhead Entrance/ Clearance, Beam Mounted 3/4" = 1'-0" Px-11b OVERHEAD CLEARANCE BEAM MOUNTED Painted 1/8 aluminum panel with black reflective vinyl letters and graphics. Painted PVC clearance bar with applied vinyl graphics and lettering. Clearance bar to have end caps. 4'-7" 1'-0" 6" ENTRANCE 7'-0" Clearance Aluminum frame is mechanically fastened to ceiling Design ReviewIntent 96
49 Px-12, Px-12a Overhead Pedestrian Px-12 OVERHEAD, PEDESTRIAN, SUSPENDED Painted 1/8 aluminum panel with reflective vinyl letters and graphics. 3/4" = 1'-0" 3'-10" 10" Elevators Aluminum frame is mechanically fastened to ceiling. Px-12a OVERHEAD, PEDESTRIAN, BEAM MOUNTED Painted 1/8 aluminum panel with reflective vinyl letters and graphics. 10" 3'-10" Elevators Design ReviewIntent ALTERNATE LAYOUTS Elevators Elevators 97
50 Px-12b Overhead Pedestrian 3/4" = 1'-0" 3'-10" 8 1/4" 4" 10" Elevators 7" 10 3/8" 1-0 Px-12b Painted 1/8 aluminum panel with reflective vinyl letters and graphics. Aluminum frame is mechanically fastened to ceiling. ALTERNATE LAYOUTS Elevators 7" 3" Elevators 4" 7" 3" 4 3/4" Patient Parking Valet Parking 3" Design ReviewIntent 98
51 Px-14 Elevator Level ID 3/4" = 1'-0" TOP VIEW ALTERNATE COLOR LAYOUT 4'-1 5/8" 3 7/8" 1 1/2" 3'-8" PORTLANDIA 2 3/4" 4'-6" Px-14 ELEVATOR LEVEL IDENTIFIER Sign is fabricated from two 1/8 (th.) painted aluminum panels. Graphics in the upper portion and lower black band are applied reflective vinyl with digitally printed graphics. Use exterior UV inks and graffiti resistant over-laminate. Silver rule lines are exposed background color. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting. PORTLANDIA 3 3/4" 3 3/8" 10 1/8" 5 1/4" PORTLANDIA 4 1/2" 2" FONT: Gotham Condensed Medium. 1 5/8" PARKING GARAGE 2 3/8" FONT: Gotham Condensed Medium. PARKING GARAGE ROOD PAVILION PARKING ONLY 2 1/2" PARKING GARAGE 1" 5 1/2" 1" FONT: Gotham Condensed Medium kerning 50% Design Intent STAFF PARKING ONLY PATIENT & VISITOR PARKING ALTERNATE MESSAGE LAYOUTS 99
52 Px-14 Elevator Level ID Layouts nts LIGHTHOUSE COAST CRATER LAKE ROSE GARDEN GARAGE C GARAGE B GARAGE D GARAGE E BRIDGE COAST FALLS COAST Design ReviewIntent GARAGE A GARAGE B GARAGE F GARAGE B 100
53 Px-14a Elevator Level ID, Small 3/4" = 1'-0" 2'-9" Sign is fabricated from two 1/8 (th.) painted aluminum panels. Graphics in the upper portion and lower black band are applied reflective vinyl with digitally printed graphics. Use exterior UV inks and graffiti resistant over-laminate. Silver rule lines are exposed background color. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting. LIGHTHOUSE FONT: Gotham Condensed Medium. LEVEL P1 GARAGE C 3'-4 1/2" Design ReviewIntent 101
54 Px-14b Elevator Level ID, Small (No Icon) 3/4" = 1'-0" Sign is fabricated from two 1/8 (th.) painted aluminum panels. Entire face of sign is applied 3M 7930 Engineer Grade Prismatic reflective vinyl with digitally printed graphics to match specified color, Black and White. Use exterior UV inks and 3M 1170 Protective Overlay Film. Silver rule lines are exposed background color. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting. 2'-9" FONT: Gotham Condensed Medium. LIGHTHOUSE Center for Health & Healing Garage LEVELP1 BUILDING 3'-9" Design ReviewIntent 102
55 Px-15/15a/15b Garage Level ID Px-15 LEVEL IDENTIFIER Sign is fabricated from an 1/8 (th.) painted aluminum panel. Graphics in the upper portion of the sign are applied reflective vinyl with digitally printed graphics. Use exterior UV inks and graffiti resistant over-laminate. Footer consists of a painted black background and applied reflective vinyl lettering. Sign panel flush mounted to wall with welded studs and silicone adhesive - no through face, or exposed mounting. Px-15a LEVEL IDENTIFIER - GUIDE (ONE LINE) Guide information is reflective vinyl with painted background. 1'-10" LIGHTHOUSE LIGHTHOUSE LIGHTHOUSE 3/4" = 1'-0" FONT: Gotham Condensed Medium. 2'-4 1/2" Maximum mounting height GARAGE C Elevators Stairs GARAGE C GARAGE C Doernbecher LIGHTHOUSE Alternate Layout Alternate Layout Px-15b LEVEL IDENTIFIER - GUIDE (TWO LINES) Minimum mounting height GARAGE C 1'-10" LIGHTHOUSE LIGHTHOUSE LIGHTHOUSE LIGHTHOUSE 6'-8" 2'-9" Design ReviewIntent 4' GARAGE C Elevators Stairs GARAGE C EMERGENCY Elevators GARAGE C Elevators Valet Pickup GARAGE C Valet Pickup on this Level Alternate Layout Alternate Layout Alternate Layout 103
56 Px-15 Garage Level ID Layouts nts LIGHTHOUSE COAST CRATER LAKE ROSE GARDEN LEVEL P1 LEVEL P2 LEVEL P3 GARAGE C GARAGE B GARAGE D P4 LEVEL GARAGE E BRIDGE COAST FALLS COAST LEVEL P5 P6 LEVEL LEVEL P7 P8 LEVEL GARAGE A GARAGE B GARAGE F GARAGE F Design ReviewIntent 104
INTERIOR DESIGN INTENT DRAWINGS - condensed version
INTERIOR DESIGN INTENT DRAWINGS - condensed version 8.10.2018 COMMENTS ADDED 11-11-16 D ~6" 1'-3 5" 2 1/2" 1/2" 5'-2" 6 5/8" 1/2" 3 1/2" Custom fabricated, double-sided cabinet with painted custom radius
More informationAJG 8-1/2" 13'-6" 2'-1 1/4" 3'-6" NIGHT VIEW N.T.S. ANIMART MADISON, WI MICHAEL OLKWITZ P-A. side view TURQUOISE AKZO NOBEL 331-A3
8-1/ 13'-" 3'-" building fascia 1" 2'-1 1/4" side view Exhibit D previously approved by the U.D.C. S/F ILLUMINATED EXTERIOR CABINET MOUNTED TO BUILDING FASCIA 12-11-0 FABRICATE CABINET FROM ABC SMALL A..125
More informationSIGN CRITERIA CONSER CROSSING MAJOR TENANTS
SIGN CRITERIA CONSER CROSSING LOCATION: ZONING DISTRICT: Southeast Corner of 151 st & Conser Street MXD EFFECTIVE DATE: August 1, 2006 MAJOR TENANTS Major Tenants A, B, C and D as shown of Figure 1, Site
More informationAddendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs
Addendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs Included documents: Principle 7 of the Design Guidelines for Lower Downtown Historic District (June 19, 2007) Sugar
More informationSign Construction and Implementation Principles
Sign Construction and Implementation Principles Revision 3.1 Curtin University Cover page 001 S 2.1 Primary identification Page 004-005 S 4.1 Tertiary identification Page 014-016 Wall Mounted Super-numerals
More informationArchitectural Excellence
Architectural Excellence 0 River Road Verona, PA 47 Tel: 4.80.00 Fax: 4.80.4404 www.buntinggraphics.com Sign Programs for Libraries Company Background Bunting Graphics is a high quality architectural fabricator
More informationExterior Signage. Design Development 75% 30 November, In collaboration with:
Exterior Signage Design Development 75% 30 November, 2016 In collaboration with: Identity ABCDEFGHIJKLMNOPQRSTUVWXYZ 1234567890 abcdefghijklmnopqrstuvwxyz Antenna Regular ABCDEFGHIJKLMNOPQRSTUVWXYZ 1234567890
More informationVINYL CLASSIC FREESTANDING PERGOLA ASSEMBLY INSTRUCTIONS
P a g e 1 VINYL CLASSIC FREESTANDING PERGOLA ASSEMBLY INSTRUCTIONS Shown: 8' x 12' Vinyl Classic Pergola with 12" Top and Main Runner Spacing The design of this pergola is based on all posts being installed
More informationConstruction Guidelines 1
Construction Guidelines 1 Addendum Log November, 2014 Full Update March, 2015 Formatting July, 2015 Editing November, 2016 Full Update February, 2017 Complete Overhaul Signage Criteria 2 Table of Contents
More informationF-4 FURNITURE. Contents
Contents F-4-1 Public Art Pole F-4-2 Banner Pole F-4-3 Typical Banner Installation F-4-4a Banner/Flower Basket Pole F-4-4b Banner/Flower Basket Pole F-4-5 Flower Basket Brackets F-4-6 TTC Station Sign
More informationSECTION INTERIOR SIGNAGE
SECTION 10 14 02 INTERIOR SIGNAGE PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by
More informationARCHITECTURAL AND IMAGE DISPLAY SIGN SYSTEM
ARCHITECTURAL AN IMAGE ISPLAY SIGN SYSTEM A unique collection of 6063T5 alloy anodizing quality aluminum sign extrusions, engineered to perform throughout the many phases of a sign project. PHPlus Architectural
More informationTO O L K IT. Public Bike Repair
TO O L K IT Public Bike Repair The Dero Tool Kit includes all the necessary tools to perform most routine maintenance and adjustments on most bikes. All the tools are securely fastened with stainless steel
More informationBIKE FILE (301)
B IK E F I L E High Efficiency The Bike File is our most space efficient u-lock compatible product. Sturdy sliding hangers allow nine bikes to be securely stored in an eight-foot section while allowing
More informationATTACHMENT B1. Typical Facility Signage Standards and Guidelines/Sign Types
7006786 TTCHMENT B1 Typical Facility Signage Standards and Guidelines/Sign Types 3.0 3.0 S - TERMINLS/GTE RES - 3.1 Sign Type Index - 3.2 Sign Types INDEX - TERMINLS/GTE RES This chapter provides specific
More informationTrack Rack. * Track Racks are not lockable
The Track Rack s unique staggered, sliding hook design creates the greatest parking efficiency while still providing easy access to any particular bike. When adding or removing a bike to the rack, simply
More informationTENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018
SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationNassau University Medical Center Campus Site ID Bid Addendum Revised
8 October 2010 Nassau University Medical Center Campus Site ID Bid Addendum Revised SITE REVIEW CL CARMAN AVENUE 7'-6" 19'-0" 3 18'-10" 35 Bus Stop 8'-6" HEMPSTEAD TURNPIKE HEMPSTEAD TURNPIKE 1ID 1 Primary
More informationTREX PERGOLA INSTALLATION INSTRUCTIONS
RECOMMENDED TOOLS/SUPPLIES: Pencil 4' Level Measuring Tape Framing Square/Speed Square 8' High Step Ladder (Two recommended) Hacksaw or Bolt Cutters Socket Wrench with 9/16" Socket and 3/4" Deep Socket
More informationAgenda Item: Revised Master Sign Plan Windsor Run Retirement Center
Agenda Item: Revised Master Sign Plan Retirement Center DATE: November 1, 2017 FROM: Mary Jo Gollnitz, Planner Background/Issue: EMH&T is requesting a revision to Retirement Center Master Sign Plan approved
More informationCity of Topeka, Kansas Wayfinding Program. Revised Design Intent - REISSUED. October 10, 2018
City of Topeka, Kansas Wayfinding Program Revised Design Intent - REISSUED October 0, 08 Lake Wellington Professional Centre Studio Suite 0-Y 6 Ken Adams Way Wellington, FL 56.8.605 axiacreative.com CONTENTS
More informationDura-Lock Roof System
DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.
More informationBol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:
Bol 8' 24' Round Tapered and Straight Wood Poles FIXTURE TYPE: PROJECT NAME: Round Taper Glulam solid wood and aluminum pole available in 8' 24' lengths. Tenon adapters, slip fitters and side bracket mounts
More informationInstallation Guide Contemporary Alfresco V1.3 LU
Installation Guide Contemporary Alfresco V1.3 LU 010818 Tools Required Below is a list of tools that you will require to install you're the Contemporary Alfresco System. Cordless Drill Mastic Gun Spirit
More informationINTERIOR DESIGN INTENT DRAWINGS - condensed version
INTERIOR DESIGN INTENT DRAWINGS - condensed version 8.10.2018 COMMENTS ADDED 11-11-16 N N-1a NOTICE HOLDER N-1b NOTICE HOLDER N-1c NOTICE HOLDER N-1d NOTICE HOLDER N-1e NOTICE HOLDER 6" 1'-5" 1'-5" APCO
More informationInstallation Guidelines
Page 1 Tools You ll Need 4 ft. Carpenter s level Chalk line (to mark U channel locations) Cordless drill/nut driver Caulking gun Chop saw with a metal cutting blade on it (required to make accurate and
More informationKO LO SH E LT E R. High Capacity and Flexibility
KO LO SH E LT E R High Capacity and Flexibility The unique styling of our redesigned Dero Kolo Shelter will help beautify your facility and provide secure, covered bike parking for cyclists. The Kolo is
More informationTH Place, Maspeth, NY Instruction Manual for UNO Exit Signs
57-10 49 TH Place, Maspeth, NY 11378 Instruction Manual for UNO Exit Signs 1. What is included in this box? Back box with electronics, battery (where applicable), & mounting hardware. Inner trim, LED illuminator
More informationULT R A S PACE SAV E R SQ UA R E D
ULT R A S PACE SAV E R SQ UA R E D Hip to be Square Dero s Ultra Space Saver Squared offers high-security, vertical bike parking. Adjustable sliding arms make it easy for customers to best utilize their
More informationPHOTOPOLYMER BRAILLE RASTER BRAILLE MOLDED BRAILLE QUICK SHIP ADA BRAILLE SIGNS. Photopolymer sign panel in a variety of thicknesses.
ADA BRAILLE SIGNS PHOTOPOLYMER BRAILLE Photopolymer sign panel in a variety of thicknesses. 1/32" raised text, graphics and Braille. Standard sizes with radius or square corners. Acrylic polyurethane finish.
More informationBike Locker Model DBL1 & DBL2
Bike Locker Model DBL1 & DBL2 DBL1 & DBL2 are constructed of 99% recycled steel and is available in 20 standard powder coat colors or a galvanized finish. DBL1 & DBL2 store 1 or 2 bikes effortlessly and
More informationINTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)
SECTION 066030 EXTERIOR PVC PERGOLAS (IBC Compliant) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and other Contract Documents, listed in the agreement between the Owner and Contractor, apply to
More informationInstallation Guide Simplicity Alfresco. V1.9 Lu070318
0333 305 5272 www.canoports.co.uk Installation Guide Simplicity Alfresco V1.9 Lu070318 Tools Required Below is a list of tools that you will require to install your the Simplicity Alfresco System. Cordless
More informationSIGN TYPES 3/3/ SIGN TYPES SIGNAGE STANDARDS MANUAL STATION SIGNS. Sign Types 8.0
8.0 Sign Types 8.0 8a.0 IDENTIFICATION SIGNAGE SIGNAGE STANDARDS MANUAL - STATION SIGNS Identification Signage 8a.0 8a.1 Cast Bronze Pin-Mounted Station Names - Wall Mounted 1. Cast bronze pin-mounted
More information5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.
2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc
More informationIntex Engineered Pergola System Installation Instructions. NOTE: See Appendix for Foundation Requirements
Intex Engineered Pergola System Installation Instructions NOTE: See Appendix for Foundation Requirements Pergola Installation, Freestanding (If pergola will be attached-to-structure, skip to page 3) 1.
More informationOXYGEN INSTALLATION. Revision date
12345 1 Hardware List 12345 Flat head wood screw #9 x 7/8 long with #2 Phillips drive, silver Used to attach surfaces and end panels Hex set screw ½-13 x 2 long with 1/4 hex drive, black Used on Legs Hex
More informationAUXILIARY FRAMING AND ACCESSORIES
CUSTOM CABINETS & RACKS STRUT AND ACCESSO- RIES JUNCTION KITS ANGLE AND BRACE KITS SPLICE KITS BRACE KITS INSTALLATION KITS WALL ANGLE KITS RUBBER END CAPS SUPPORT INSTALLATION AND SUPPORT KITS STANCHION
More informationDRAFT V. SITE ELEMENTS SIGNS
1. SIGNS Intent Signs are an important streetscape design element that affect not only the visual character of the Historic District but also the vitality of its businesses. Signage provides business identification,
More informationA. Submit manufacturer's technical data and installation for each type of sign required.
SECTION 10425 PART ONE GENERAL 1.1 SECTION INCLUDES A. Interior Building Signage. B. Handicapped parking signs. C. Permanent Project Sign. 1.2 DESCRIPTION A. Signage shall consist of room number and room
More informationCROSSBAR RAFTER ISOMETRIC
Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are
More informationEquilibrium. Conference Table. Installation Instruction. Revision B 11/07/16
Equilibrium Conference Table Installation Instruction Revision B 11/07/16 Equilibrium End User Agreement Enwork Equilibrium table bases must be installed directly onto a four inch minimum thickness concrete
More information1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards. B. See Division 5 Section "Pipe and Tube Railings"
More informationDisassembly Instructions for Recycling June 10, 2010
Disassembly Instructions for Recycling June 10, 2010 These instructions apply to all workstation and wall products. Disassembly Once workstations or walls are dismantled as described under Disassembly
More informationA. Product Data: For each electrical identification product indicated.
SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationDW HORIZONTAL INSTALLATION
AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S
More informationNew Product Release: October 2014 Boone Racks
New Product Release: October 2014 Boone Racks Double Fido Fountain Mounting: Surface NOTE: THESE ROUGH-IN DIMENSIONS MAY VARY ½: (13 mm) PLUS OR MINUS NOTE: All dimensions subject to manufacturing variance
More information1.1. Multi-Panel Series
Multi-Panel Series 1.1.100 The Multi-Panel, or MP, concept accommodates independent multiple sign panels for total flexibility, changeability and replacement. Winner of The Certificate of Recognition for
More informationOpen Up Your View With CABLE SYSTEMS
Open Up Your View With CABLE SYSTEMS PRESENTED BY CROWN HERITAGE Our Cable Multiple options to accomodate any deck or stair design Marine Grade 316 stainless steel Swaging is the term used for attaching
More information12 x 24 Flat Top Pergola
A S S E M B LY G U I D E OPTIONAL ACCESSORIES: Bolt Down Bracket Kit Privacy Wall (6 for Pergola) Pergola Planter Ver.-75 Ta b l e o f Co n t e n t s PAGE Introduction & Overview......................................................
More informationALL SEASON PATIO COVER
ALL SEASON PATIO COVER 61 Where the All Season Patio Cover is to be attached to the home, create a level line showing where the top of the mounting rail is to be located. Install each section with the
More informationINSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
More informationDUALCASE VERSATILE ALUMINIUM SIGN SYSTEM
VERSATILE ALUMINIUM SIGN SYSTEM Universal Components Ltd. May 2007 Introduction Nothing beats DualCase for speed of fabrication, aesthetic appearance and easy maintenance. With the minium of components
More informationInstallation Instructions
Column & Beam Units with Debris Netting Installation Instructions Laminated Wood Systems, Inc. Seward, Nebraska 800-949-3526 2015 LWS, INC. AVR-NET INSTALL 05-12-16 AVR Installation Notes 1 Safety The
More informationMODERN PERGOLA INSTALLATION GUIDE. When only the best will do.
MODERN PERGOLA INSTALLATION GUIDE When only the best will do. TOOLS LIST Drill(s) 3/8" Magnetic Driver (s) 12" Drill Extension #2 Square Drive bit for Drill or Driver Level Tape Measure Hammer Drill if
More informationOxford Stalls Installation Instructions
Oxford Stalls Installation Instructions RAMM Horse Fencing and Stalls 13150 Airport Hwy. Swanton, OH 43558-9615 1-800-434-8456 Rev. 8/15/17 Before You Start Typical stall sizes are 10 x 10, 12 x 12 or
More informationDowntown Rack. Custom logo option available
Custom logo option available Downtown Rack The Downtown Rack uses thick, square-tube construction that can t be cut with a pipe cutter. The extended width of the Downtown Rack makes for easy bike parking
More informationINSTALLATION INSTRUCTIONS. Deluxe Continuous Hinge Inline Door & Panel Shower Enclosure QCI5230
INSTALLATION INSTRUCTIONS Deluxe Continuous Hinge Inline Door & Panel Shower Enclosure QCI5230 QCI5230 Rev 0 6 shower new QCI5230 Rev 0 Page 2 Certified 06/20/2016 Parts List A. Curb (w/ weep holes) (1)
More informationH O O P RAC K. Simple Security
H O O P RAC K Simple Security The Hoop Rack is a proven design that provides high security and easy bike parking. The Hoop Rack uses thick pipe construction and the full radius of the bend makes the Hoop
More informationSutton Screened in Awning / Porch
Sutton Screened in Awning / Porch Sections: Project Overview Roof Work Cedar Framing Canopy Frame Screen Frames Misc. Sheet 1 - - - Index Sheet 2 - - - Project Summary Sheet 3 - - - Roof Work overview
More informationCHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT COLLEGE CAMPUS MASTER SIGN PROGRAM, PHASE 2 BID NO
CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT COLLEGE CAMPUS MASTER SIGN PROGRAM, PHASE 2 BID NO. 18-04 ADDENDUM NO. ONE DATE: September 07, 27 CLIENT / PROJECT: Chabot-Las Positas CCD Campus Master
More informationSINGLE TRACK BYPASS (patent pending) barn door hardware
SINGLE TRACK BYPASS (patent pending) barn door hardware Installation Manual What is included in your kit: Part number Part name Quantity 1 Inner door hanger 2 2 Outer door hanger 2 3 5/16 x 1.5 lag bolts
More informationDoor Canopy. PDL Building Products Industrial Parkway, N. Olmsted, OH Phone:
Door Canopy Door Canopies are attractive and efficient while eliminating the need and expense of drafting and manufacturing canopies as part of the building package. Construction: 26 gauge material around
More informationNX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP
6-1/4 HANDRAIL W/ VINYL HANDGRIP TYPICAL ASSEMBLY 5 2 BUTT JOINT 12 10 9 1 8 11 6 3 7 4 BUTT JOINT COMPONENT LIST 1 LEFT RETURN 7 UPPER IMPACT ABSORBER 2 RIGHT RETURN 8 LOWER IMPACT ABSORBER 3 OUTSIDE
More informationSignage systems by ETC
Signage systems by ETC Built-up Premium Metal Letters 2 Fabricated Signage 7 Fabricated Totems & Monoliths 10 Flat Cut Metal Letters 12 Luxury Illuminated Letters 14 Electro-Tech Colour Ltd. 1 Blenheim
More informationSIGNAGE CRITERIA THE PLACE TO SHOP FASHION DISTRICT PHILADELPHIA
SIGNAGE CRITERIA THE PLACE TO SHOP ADDENDUM LOG October, 2009 Updated to current layout February, 2014 Updated Primary Sign Design Requirements (s5 #11) December, 2014 Removed website address language
More informationS W E RV E RAC K. Simple Security. Simple Stability.
S W E RV E RAC K Simple Security. Simple Stability. The Swerve Rack is a proven design that provides high security and easy bike parking. The Swerve Rack uses thick pipe construction and the full radius
More informationVersatrac R-System Stock Extrusions, Clips and Accessories
Versatrac R-System Extrusions are available in 300 series (for 3 3/4" walls) and 400 series (for 4 7/8" walls). Standard finishes are Satin Metallic Bronze, Satin Black, Satin White Baked Enamel, and Clear
More informationTable and Furniture Base Fittings Plinth Adjusting Fittings
Adjusting screw with M8 or M thread Rigid, for glide inserts, steel thread Finish/Colour: Black, thread galvanized Version: With acceptance Ø30 mm Thread M8 650.22.381 M 650.22.382 Packing: 1 or 0 pcs.
More informationARB MEETING DATE: APRIL 17, 2017 BUSINESS NAME: 1 WALL MOUNTED SIGN 4 WALL MOUNTED, 1 FREESTANDING SQUARE FEET
ARCHITECTURAL REVIEW BOARD SIGN FORM BUSINESS NAME: WORLD FINANCE AND LOANS LOCATION: 205 N. GOOSE CREEK BLVD./STE. 104 NUMBER & TYPE OF SIGNS APPLYING FOR: NUMBER OF ALLOWABLE SIGNS: MAXIMUM ALLOWABLE
More informationH O O P RAC K. Simple Security
H O O P RAC K Simple Security The Hoop Rack is a proven design that provides high security and easy bike parking. The Hoop Rack uses thick pipe construction and the full radius of the bend makes the Hoop
More informationa.k.a. casegoods instructions
a.k.a. casegoods instructions a a.k.a. workwall installation IMPORTANT NOTES Failure to install product according to installation instruction will result in loss of warranty. Tools required for assembly
More informationSETUP INSTRUCTIONS If you would like to tell us about your experience with your setup instructions please us at
207 VK-964 General Layout 0 0 Plan View www.classicexhibits.com SETUP INSTRUCTIONS If you would like to tell us about your experience with your setup instructions please email us at info@classicexhibits.com
More information10 x 10 Arch Top Pergola
0 x 0 Arch Top Pergola I N S T A L L A T I O N G U I D E O P T I O N A L A C C E S S O R I E S Privacy Fence Panel System ( Panels & Middle Post Included) Bolt Down Bracket Kit (Set of ) Additional Shade
More informationSIGNAGE DESIGN CRITERIA
SIGNAGE DESIGN CRITERIA THE PLACE TO SHOP THE PLACE TO SHOP ADDENDUM LOG July, 2009 TCM generated, full update to new layout August, 2009 Storefront signage requirement update November, 2011 Updated Letter
More informationDouble Beam Freestanding Pergola Installation Guide
Double Beam Freestanding Pergola Installation Guide Patent Pending. Copyright 2011 USAVinyl, LLC - All Rights Reserved The information contained in these instructions are proprietary to USAVinyl, LLC and
More informationFIB-R-MAX STANDARD SINGLE DOOR
FIB-R-MAX STANDARD SINGLE DOOR Style 1, 4, 4.4 and 11 Unitized Single Door Assembly By Fib-R-Max for Existing Openings 1. Set the crate, which will be marked with the specific opening location, at the
More information1. Show the following information with additional information necessary to indicate shop compliance with the requirements of this section.
SECTION 12360 LIBRARY SHELVING PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 06100 - Carpentry. 2. 09200 - Metal Studs, Lath, Suspension Ceiling, Plaster and Stucco. 3. 09660 - Resilient Tile Flooring.
More information5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER
1/2 K.O. (3/8 K.O. on 165 with factory supplied 3/8 flex conduit fitting) TR - Trim Flange Side Blocking Install Method Secure fixture to structure following instructions below: 1. Remove lens and internal
More informationBEST PRACTICE GUIDE. Socket Bases. Working with Concrete Slabs
Working with Concrete Slabs When working with concrete slabs the barrier protection can be erected in three ways - with socket bases, adjustable slab edge brackets and multi slab clamps. Socket Bases 1
More information10 x 10 Flat Top Pergola
0 x 0 Flat Top Pergola A S S E M B L Y G U I D E Models: Venetian, Tuscany, Luxor, Acadia O P T I O N A L A C C E S S O R I E S Arch Kit System ( Arches) Privacy Fence Panel System ( Panels & Middle Post)
More informationSECTION METAL FABRICATIONS
SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM
More informationINTRODUCTION. EqunioxRoof.com. Pro Tip
INSTALLATION MANUAL INTRODUCTION The Equinox Louvered Roof System is designed to be installed in an aluminum frame. All these sections are 1/8" thick extruded aluminum. All engineering for this system
More informationSanta Fe Cover INSTALLATION GUIDE. Alumawood TM Newport with MAXX Panel TM Installation Guide
Alumawood TM Newport with MAXX Panel TM Installation Guide Santa Fe Cover INSTALLATION GUIDE Whatever the weather, you can enjoy the sophisticated charm of a lattice cover. The Santa Whatever the weather,
More informationULT R A SPAC E SAV E R
ULT R A SPAC E SAV E R Double Capacity, Modular Construction The Ultra Space Saver provides easy and ample space for u-lock security on nearly any bike, including bikes with fenders. Thanks to design enhancements,
More information2013 Feeney (2/14) # B. Aluminum Railing Systems
2013 Feeney (2/14) #2012-425B Aluminum Railing Systems Aluminum Railing Systems Searching For a Complete Railing System? Look No Further. DesignRail by feeney aluminum railing frame systems combine the
More information12 x 12 Flat Top Pergola
x Flat Top Pergola A S S E M B LY G U I D E Model: Freemont OPTIONAL ACCESSORY Bolt Down Bracket Kit ( for Pergola) Ver /NOV 00 AI-BP0-0- Ta b l e o f Co n t e n t s PAGE x Flat Top Pergola Introduction
More informationQueens Center Mall Queens Blvd., Elmhurst, NY 11373
TABLE OF CONTENTS SIGNAGE & GRAPHICS General Signage Requirements General Requirements for Primary Sign Design Primary Signage Design Primary Signage Examples Alternate Signage Storefront Window Signs,
More informationGLOSSARY OF TERMS SECTION 8
GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the
More informationHeight Adjustable Benching End Panel and Utility Pole
Height Adjustable Benching End Panel and Utility Pole Tools required: END PANEL Jig Saw Power Drill END PANEL WITH UTILITY POLE Bit Holder Long #2 Square Drive Bit 5mm Hex Drive Bit UTILITY POLE Level
More informationP /8 Ring Diameter 90. Trim Ring Mounting Holes P /8. 393/16 Ring Diameter. Stud Minimum
PARTS LIST VARIABLE Top Over Head Support Bracket 1 872070 P4000-SMR Over Head Joiner Bracket 1 VARIABLE Bottom Over Head Bracket 1 79741 P4000-SMR 4 Angled Leg 4 100-00230-14 1/4-20 x 31/2 RD. HD. MS.
More informationMX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP
6-1/4 HANDRAIL W/ VINYL HANDGRIP TYPICAL ASSEMBLY 5 2 BUTT JOINT 12 10 9 1 8 11 6 3 7 4 BUTT JOINT COMPONENT LIST 1 LEFT RETURN 7 UPPER IMPACT ABSORBER 2 RIGHT RETURN 8 LOWER IMPACT ABSORBER 3 OUTSIDE
More informationARCHITECTURAL REVIEW BOARD STAFF REPORT. ARB : Super Test Sunoco Fuel Pump Canopy and Signs
ARCHITECTURAL REVIEW BOARD STAFF REPORT Project #/Name Review Type Parcel Identification Zoned Owner/Applicant Magisterial District Proposal Context Visibility ARB-2012-43: Super Test Sunoco Fuel Pump
More informationSIGNAGE DESIGN CRITERIA LA ENCANTADA
SIGNAGE DESIGN CRITERIA THE PLACE TO SHOP ADDENDUM LOG October, 2009 Updated to current layout April, 2014 Added Exit Corridor language (t11) October, 2014 At grade level electrical conduit is not allowed
More informationSIGNAGE DESIGN CRITERIA
SIGNAGE DESIGN CRITERIA THE PLACE TO SHOP ADDENDUM LOG December, 2012 Updated to current layout January, 2013 Inserted front cover photo February, 2014 Updated Primary Sign Design Requirements (s5 #11)
More information400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS
12/11/07 PAGE 1 OF 12 400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS Thank you for purchasing our product! *Please read these instructions
More informationMECHANICAL BACK FASTENED SYSTEMS INSTALLATION DATA
MECHANICAL BACK FASTENED SYSTEMS INSTALLATION DATA 7/16 PETRARCH ARCHITECTURAL WALL PANELS APPLIED OVER A STUDWALL BY MEANS OF A FIELD ASSEMBLED BACK FASTENED SYSTEM DESIGN CONCEPT 7/16 panels may be installed
More informationClopay Models 835/837 Sliding Door System Installation Guide
Clopay Models 835/837 Sliding Door System Installation Guide The aim of this instruction is to guide you through the process of construction and fitting of Sliding Doors. Due to the number of sizes available
More informationWALL TO FABRICATED FLOOR
WALL TO FABRICATED FLOOR PERIMETER WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN PARTITION WALL IS HELD IN PLACE BY WOODEN STRIP SCREED OPTIONAL NSF COVED FLOOR IS SHOWN
More information12 x 12 Flat Top Pergola
x Flat Top Pergola Model: Regency, Roosevelt A S S E M B L Y G U I D E O P T I O N A L A C C E S S O R Y Bolt Down Bracket Kit ( for Pergola) Ver./MAR 0 Ta b l e o f Co n t e n t s PAGE x Flat Top Pergola
More information