1 3933 US Route 11 Cortland, NY 1345 Telephone: (67) Facsimile: (67) March 2, 216 Test Report Number: CRT-14 Project Number: Legrand North America 125 Eugene O Neill Drive New London, CT 632 Ph (86) Fax (86) Superior Essex 612 Powers Ferry Road Suite 15 Atlanta, GA 3339 TEST: Electrical transmission performance testing of a cabling configuration to the requirements of ANSI/-568-C.2 for Category 6A and the /IEC 1181 Edition 2.2 for Class E Channels. SAMPLE DESCRIPTION: The client supplied and tested a 2-Connector channel as illustrated below and referenced to as ncompass CAT 6A U/UTP Channel, 2-Connector, 15 meters (49.2 ft) Alien Crosstalk Setup: Cables 6 around 1 bundled 1 4 Component ID Manufacturer Part Number Length/Qty Description 1 Superiorr Essex 6A-272-6B 133 m (42.6 ft) 1Gain Cable, C6A U/UTP CMP 2 Ortronics, Inc. OR-PHA61U24 1 C6A 24 Port Panel 3 Ortronics, Inc. OR- OR-KT2J6A 7 C6A Keystone Jacks* 4 Ortronics, Inc OR-MC6A3-6 1m (3.3 ft) 2 U/UTP Patch Cords *Note: OR-KT2J6A jacks mounted in a 24 Port Panel (OR-SPKFU24)) STANDARDS USED: ANSI/-568-C.29: Balanced Twisted-Pair Telecommunicationss Cabling and Components Standard, dated August 29 /IEC information Technology Generic cabling for customer premises, Second edition dated September 22 including amendments up to Amendment 2, datedd April 21 Page 1 of 2 This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only inn its entirety. Any usee of the Intertek name or one of its marks for the sale or advertisement of the ested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. Intertek Testing Services NA, Inc.
2 Legrand Test report number CRT-14 March 2, 216 SECTIONS USED: Section 6.2 of ANSI/ 568-C.2: Channel transmission performance (6.2.1 to ) Section 6.4 of /IEC 1181: Channel transmission performance (Sections to and to ) AUTHORIZATION: The project was authorized by Mr. Rob Aekins RCDD, representing Legrand Data Communications Incorporated. EQUIPMENT LIST: The following equipment was employed in conducting the tests. Equipment used Model number Serial number Calibration date Calibration due date Agilent Technologies Network Analyzer E571B MY /27/215 7/27/216 Hewlett Packard Multimeter 3441A US /27/215 7/27/216 DATE OF TEST: February 1, 216 TEST REPORT REVISION HISTORY: First Issue: March 2, 216 Original Document RESULTS: See appendixes A through C for the test results. CONCLUSION: The channel cabling configuration, as previously described and supplied by the client, was tested in accordance with the standards referred to herein, and did comply with the indicated applicable transmission requirements. The procedures and requirements from the standards were followed, and the testing was performed at the client s facility as part of their qualifications under Intertek s SAT program. Reviewed and Approved By: Antoine Pelletier Project Engineer Global Cabling Products Testing John Cash Associate Engineer Global Cabling Products Testing Page 2 of 2 Intertek Testing Services NA, Inc.
3 Legrand Test report number CRT-14 March 2, 216 Appendix A Test results Internal (core) transmission characteristics of the disturbed channel This appendix contains 7 pages. Intertek Testing Services NA, Inc.
4 Report Number: CRT-14.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Cat 6A / Class Ea Channel NEXT as measured from the TELECOMMUNICATIONS ROOM (TR) _CH LIMIT _CH LIMIT PrC 13 PrC 12 PrC 14 PrC 23 PrC 24 PrC Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT (MHz) (MHz) Freq s n/a 65. n/a NEXT as measured from the WORK AREA (WA) _CH LIMIT _CH LIMIT PrC 13 PrC 12 PrC 14 PrC 23 PrC 24 PrC Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT (MHz) (MHz) Freq s n/a 65. n/a Appendix A Page 1 of 7 Legrand
5 Report Number: CRT-14.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Cat 6A / Class Ea Channel PSNEXT as measured from the TELECOMMUNICATIONS ROOM (TR) _CH LIMIT CH LIMIT -12 Case (MHz) (MHz) Freq s n/a 65. n/a PSNEXT as measured from the WORK AREA (WA) _CH LIMIT _CH LIMIT -12 Case (MHz) (MHz) Freq s n/a 65. n/a Appendix A Page 2 of 7 Legrand
6 Report Number: CRT-14.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Cat 6A / Class Ea Channel RL as measured from the TELECOMMUNICATIONS ROOM (TR) _CH LIMIT _CH LIMIT -75 Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT (MHz) (MHz) Freq s n/a 65. n/a RL as measured from the WORK AREA (WA) _CH LIMIT _CH LIMIT -75 Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT (MHz) (MHz) Freq s n/a 65. n/a Appendix A Page 3 of 7 Legrand
7 Report Number: CRT-14.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Cat 6A / Class Ea Channel ACRF _CH LIMIT _CH LIMIT PrC12 PrC13 PrC14 PrC21 PrC23 PrC24 PrC31 PrC32-12 PrC34 PrC41 PrC42 PrC43-14 Case Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT (MHz) (MHz) Freq s n/a 65. n/a PSACRF _CH LIMIT _CH LIMIT Case (MHz) (MHz) Freq s n/a 65. n/a Appendix A Page 4 of 7 Legrand
8 Report Number: CRT-14.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Cat 6A / Class Ea Channel TCL as measured from the TELECOMMUNICATIONS ROOM (TR) _CH LIMIT _CH LIMIT Case (MHz) (MHz) Freq s n/a 65. n/a TCL as measured from the WORK AREA (WA) _CH LIMIT _CH LIMIT Case (MHz) (MHz) Freq s n/a 65. n/a Appendix A Page 5 of 7 Legrand
9 Report Number: CRT-14.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Cat 6A / Class Ea Channel ELTCTL as measured from the TELECOMMUNICATIONS ROOM (TR) _CH LIMIT _CH LIMIT Case (MHz) (MHz) Freq s n/a n/a n/a 62.5 n/a n/a 1. n/a n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a ELTCTL as measured from the WORK AREA (WA) _CH LIMIT _CH LIMIT Case (MHz) (MHz) Freq s n/a n/a n/a 62.5 n/a n/a 1. n/a n/a 2. n/a n/a 25. n/a n/a 3. n/a n/a 4. n/a n/a 5. n/a n/a 65. n/a Appendix A Page 6 of 7 Legrand
10 Report Number: CRT-14.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Cat 6A / Class Ea Channel INSERTION LOSS (ATTN) Case -1-3 _CH LIMIT _CH LIMIT -5 Freq Measured Calculated CH LIMIT Freq Calculated CH LIMIT (MHz) (MHz) Freq s n/a 65. n/a DC Loop Resistance (Ohms) ChnlLimit Max Min DC Resistance Unbalance (%) ChnlLimit Max Min GLOSSARY of TERMS Calculated : s: Frequency : LIMIT : Measured : Freq: Freq (): Case: ACR / PSACR: The minimum difference in db between the measured value and the LIMIT value at the specifed frequency point for all tested pairs (Calculate@1MHz = Measured@1MHz - LIMIT@1MHz ). Specific reference points of interest in MHz within the swept frequencies. A specific frequency point in megahertz (MHz) for which the data indicated is applicable. The calculated response LIMIT in db at the indicated frequency point as calculated using applicable equations defined by the appropriate standard. The worst case measured response in db at the frequency indicated for all tested pairs. The band of measured values from 1 MHz to the upper frequency LIMIT as defined by the category of test. The minimum margin in db detected across the Frequency band. A composite value calculated from the maximum response of each pair or pair combination at a given frequency. (Case 1MHz = Max( 1MHz, 1MHz, 1MHz, 1MHz ) etc. If Provided are for reference only. Limit line(s) are provided for reference and are calculated as the difference between the applicable NEXT Loss and Insertion loss limits (ACR limit = NEXT limit - IL limit ). Appendix A Page 7 of 7 Legrand
11 Legrand Test report number CRT-14 March 2, 216 Appendix B Test results Alien transmission characteristics (6 around 1 test configuration) This appendix contains 4 pages. Intertek Testing Services NA, Inc.
12 Report Number: CRT-14.xlsx Test Standard: ANSI/-568-C.2 PowerSum Alien Near-End Crosstalk (PSANEXT) Limit -12 Case Frequency Calculated Measured CH LIMIT (MHz) Freq s n/a Average PowerSum Alien Near-End Crosstalk (avgpsanext) Avg Limit All -12 Case Frequency Calculated Measured CH LIMIT (MHz) Freq s n/a Appendix B Page 1 of 4 ORTRONICS - C6A Channel
13 Report Number: CRT-14.xlsx Test Standard: ANSI/-568-C.2 Power Sum Attenuation to Alien Crosstalk Ratio Far-End (PSAACRF) Limit Case Frequency Calculated Calculated CH LIMIT (MHz) Freq s n/a Average Power Sum Attenuation to Alien Crosstalk Ratio Far-End (avgpsaacrf) Avg Limit All Case Frequency Calculated Calculated CH LIMIT (MHz) Freq s n/a Appendix B Page 2 of 4 ORTRONICS - C6A Channel
14 Report Number: CRT-14.xlsx Test Standard: ANSI/-568-C.2 PowerSum Alien Near-End Crosstalk (PSANEXT) Limit -12 Case Frequency Calculated Measured CH LIMIT (MHz) Freq s n/a Average PowerSum Alien Near-End Crosstalk (avgpsanext) Avg Limit All -12 Case Frequency Calculated Measured CH LIMIT (MHz) Freq s n/a Appendix B Page 3 of 4 ORTRONICS - C6A Channel
15 Report Number: CRT-14.xlsx Test Standard: ANSI/-568-C.2 Power Sum Attenuation to Alien Crosstalk Ratio Far-End (PSAACRF) Limit Case Frequency Calculated Calculated CH LIMIT (MHz) Freq s n/a Average Power Sum Attenuation to Alien Crosstalk Ratio Far-End (avgpsaacrf) Avg Limit All Case Frequency Calculated Calculated CH LIMIT (MHz) Freq s n/a Appendix B Page 4 of 4 ORTRONICS - C6A Channel
16 Legrand Test report number CRT-14 March 2, 216 Appendix C Test results ACR transmission performance provided for reference ONLY This appendix contains 2 pages. Intertek Testing Services NA, Inc.
17 Report Number: CRT-14.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Cat 6A / Class Ea Channel 4 _CH LIMIT _CH LIMIT PrC 12 (MHz) (MHz) PrC 13 PrC 14 Freq PrC 23 PrC 24 s PrC NOTE: Limit line/values provided for reference ONLY and are extrapolated n/a 65. n/a from NEXT Loss and IL limit requirements. ACR limit = NEXT limit - IL limit Pair-to-Pair ACR as measured from the TELECOMMUNICATIONS ROOM (TR) Case Pair-to-Pair ACR as measured from the WORK AREA (WA) 4 _CH LIMIT _CH LIMIT PrC 12 PrC 13 PrC 14 PrC 23 PrC 24 PrC Case (MHz) (MHz) Freq s n/a 65. n/a Appendix C Page 1 of 2 Legrand
18 Report Number: CRT-14.xlsx Test Standards: ANSI/-568-C.2 and /IEC 1181 Cat 6A / Class Ea Channel Power Sum (PS) ACR as measured from the TELECOMMUNICATIONS ROOM (TR) 4 _CH LIMIT Case _CH LIMIT (MHz) (MHz) Freq s NOTE: Limit line/values provided for reference ONLY and are extrapolated n/a 65. n/a from PSNEXT Loss and IL limit requirements. psacr limit = psnext limit - IL limit Power Sum (PS) ACR as measured from the WORK AREA (WA) 4 _CH LIMIT _CH LIMIT -12 Case (MHz) (MHz) Freq s n/a 65. n/a Appendix C Page 2 of 2 Legrand
125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860)
3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com December 16, 214 Test Report Number: 33592CRT-137 Project Number: 33592 Legrand North America Superior
More information125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860)
3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com December 16, 214 Test Report Number: 33592CRT-136 Project Number: 33592 Legrand North America Superior
More informationTest report number CRT-001b Project number CRT-001b
3933 US Route 11 Cortland, NY 13 Telephone: (7) 3-6711 Facsimile: (7) 8-39 www.intertek.com July 24, 215 Nexans Cabling Solutions Alsembergsesteenweg 2, b3 B-151 Buizingen BELGIUM Test report number 12193693CRT-1b
More informationDELTA Test Report. Certification testing of generic cabling products: Unscreened channel, Class E, 4 connector model. Performed for Sterling
DELTA Test Report TEST Reg. no. 19 Certification testing of generic cabling products: Unscreened channel, Class E, 4 connector model Performed for Sterling DANAK-19/16909 Project no.: T213173-01 Page 1
More informationQualification testing of 100 ohm shielded channel, Class EA. Performed for Tyco Electronics Raychem N.V.
We help ideas meet the real world DELTA Test Report DANAK TEST Reg. no. 19 Qualification testing of 100 ohm shielded channel, Class EA Performed for Tyco Electronics Raychem N.V. DANAK-19J1636 Project
More information1) The addition of TCL and ELTCTL requirements to Category 6
Subject 444 TO: SUBJECT: 455 East Trimble Road San Jose, CA 95131 July 28, 2008 Subscribers to UL s Listing and Verification Services for Communications Cable (DUZX) Revised Test and Follow-Up Service
More informationPDI TEST REPORT. No.0437
ABN 21 002 065 769 PDI TEST REPORT No.0437 COMPREHENSIVE Cat 6 TRANSMISSION TESTING ON 4 Pair 5m RJ45 Patch Cord With COBLE (COB) Cat 6 RJ45 Plug for Australian Communications Laboratories Pty Ltd DATE:
More informationAMP NETCONNECT Category 6 System
AMP NETCONNECT Category 6 System 2 How Did We Get Here? Basic Cabling Structure Component Specifications Link/Channel Specifications Additional Structure Options EIA/TIA TSB36 EIA/TIA 568 TIA/EIA TSB40
More informationTEST REPORT. Report Number: MPK-007 Project Number: Report Date: August 31, 2007
TEST REPORT Report Number: 3131957MPK-007 Project Number: 3131957 Report Date: August 31, 2007 Testing performed on the Patient Remote Control Model #: SC-5212 FCC ID: Q4D-PSC5210W to FCC Part 15.209 and
More informationThis is a preview - click here to buy the full publication
ISO/IEC TR 11801-9901 TECHNICAL REPORT Edition 1.0 2014-10 colour inside Information technology Generic cabling for customer premises Part 9901: Guidance for balanced cabling in support of at least 40
More informationTEST REPORT. ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source TEST REPORT Intertek Testing Services NA, Inc. 16015 Shady Falls Road Elmendorf,
More informationThis document is a preview generated by EVS
TECHNICAL REPORT ISO/IEC TR 11801-9901 Edition 1.0 2014-10 colour inside Information technology Generic cabling for customer premises Part 9901: Guidance for balanced cabling in support of at least 40
More informationn Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs.
INTRODUCTION Structured Cabling or data cabling (also known Local Area Network or LAN Cabling) is increasing in its deployment for business, commercial and residential use to carry signaling for networks
More informationTEST REPORT. ASTM E648 Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
ASTM E648 Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source TEST REPORT Self Adhesive Vinyl; ID: panorama Walk & Wall Project No. 101611878SAT-001A
More informationTEST REPORT. DANAK Reg. no. 19. Electrical performance testing of: Connecting Hardware according to IEC
Page 1 of 12 2 Appendices TEST REPORT DANAK Reg. no. 19 DELTA Danish Electronics, Light & Acoustics Venlighedsvej 4 DK-2970 Hørsholm Denmark Tel. (+45) 45 86 77 22 Fax (+45) 45 86 58 98 www.delta.dk Electrical
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61935-1 Edition 3.0 2009-07 Specification for the testing of balanced and coaxial information technology cabling Part 1: Installed balanced cabling as specified in ISO/IEC 11801
More informationREQUIREMENTS FOR DIRECTIONAL LAMPS, LIGHT EMITTING DIODE LAMPS AND RELATED EQUIPMENT ACCORDING TO THE EC REGULATION 1194/2012
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Telephone: (852) 2173 8888 Facsimile: (852) 2785 5487 www.intertek.com REQUIREMENTS FOR DIRECTIONAL LAMPS, LIGHT EMITTING DIODE LAMPS AND
More informationTest Report based on DIN EN ISO/IEC 17025: 2005
Test Report based on DIN EN ISO/IEC 1725: 25 GHMT Type Approval 2 Connector Permanent Link, Copper, Class EA according ISO/IEC 1181-1 Ed.1. Document-no: P582a-18-E This Test Report with the measurements
More informationTEST REPORT. ASTM E648 Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
ASTM E648 Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source TEST REPORT Reward Prefinished Engineered Hardwood Flooring; ID: REW1265PWOV Project
More informationEESTOR INC. TEST REPORT
EESTOR INC. SCOPE OF WORK Performance testing of capacitive samples (Ceramic samples called 361-1, 358-4, 358-5) REPORT NUMBER 103362995DAL-003 ISSUE DATE 29-JAN-2018 REVISION DATE 28-FEB-2018 PAGES 6
More informationCabling Ad Hoc Cat 5e Measurements
Cabling Ad Hoc Cat 5e Measurements Larry Cohen Solarflare Communications 1 Overview Cabling Ad Hoc Test Plan Measurement One Cat 5e horizontal cable sample, four test channel configurations characterized
More informationTest Report based on DIN EN ISO/IEC 17025:2005
Test Report based on DIN EN ISO/IEC 1725:25 GHMT Type Approval 2 Connector Permanent Link, Copper, Class E according ISO/IEC 1181-1 Ed.1. 217-11 Document-no: P4945b-18-E This Test Report with the measurements
More informationTEST REPORT. : The submitted samples complied with the above EMC standards. TRF No.: AS NZS (2012)-b
TEST REPORT Applicant Name & Address Manufacturing Site Sample Description Product Model No. : Shenzhen SOFARSOLAR Co., Ltd. 3A-1, Huake Building, East Technology Park, Qiaoxiang Road, Nanshan District,
More informationTEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG
TEST REPORT Report Number: 100511823MIN-001 Rev 1.1 Project Number: G100511823 Testing performed on the 2102 IPG FCC ID: SVHBAROSTIMIPG1 Industry Canada ID: 9464A-IPG210A to 47 CFR Part 95 Subpart I:2013
More informationProduct Bulletin. Belden DataTwist 4800 Cables
Product Bulletin PB 296 Belden DataTwist 4800 Cables DataTwist 4800 UTP Cables provide significant headroom and robust data transmission performance for today s most demanding applications. The cables
More informationUTP Copper. SFTP Copper. FUTP Copper. Composite. Special Applications Copper. Category 5e. Category 6 Category 5E Category 3. Category 7A Category 7
05/2011 Table of Contents n Table of Contents 1 n Product Selection 2 n HCM Overview 4 n HCM Certified Cabling Systems 6 n UTP Copper 8 n SFTP Copper 32 n FUTP Copper 36 n Special Applications Copper 42
More informationEMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009
Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203
More informationEMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan
Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE
More informationEMC VERIFICATION SUMMARY Report No.: SZHH
EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA
More informationField Measurements of Return Loss
Field Measurements of Return Loss White Paper By Mark Johnston and Jim Tonti Microtest October 21, 1998 Page 1 12/15/99 Overview Return loss is an important new measurement used to qualify the performance
More information- Characteristic impedance of cabling links is characterised by Return Loss
ISO/IEC 11801 ISO 11801 is the principle design standard for structured cabling systems for all countries of the world that do not have more specific standards, such as ISO 11801 (European Union), TIA
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD IEC 61935-1 Edition 4.0 2015-12 colour inside Specification for the testing of balanced and coaxial information technology cabling Part 1: Installed balanced cabling as specified
More informationECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R
Page 1 of 17 FCC PART 15, SUBPART B and C TEST REPORT for ECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R Prepared for UNIVERSAL ELECTRONICS, INC. 201 E. SANDPOINTE, 8 TH FLOOR SANTA ANA,
More informationFCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD
FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD IC #: 4324A-BRCM1029 REPORT NUMBER: 07U11199-1C ISSUE DATE:
More informationIndependent Testing - For End User Confidence
Independent Testing - For End User Confidence ELECTRICAL TRANSMISSION PERFORMANCE TESTING OF SCREENED CATEGORY 6 ISO/IEC, EN & TIA/EIA CONNECTING HARDWARE ACCORDING TO REQUIREMENTS OF 2ND EDITION ISO/IEC
More informationN/A. An independent organization testing for safety, performance, and certification.
September 27, 2012 Vicsa Safety S.A. Casa Matriz Pintor Cicarelli 683-SAN JOAQUÍN SAN CHILI Intertek Test Report Number: G100766457CRT-121 Dear Claudio Martinez Muratsuka: Intertek has completed the evaluation
More informationSamtec MODS-LJ Series (LIFEJACK ) Category 5/5e Qualification
Samtec MODS-LJ Series (LIFEJACK ) Category 5/5e Qualification J. Ferry, C. Arroyo Copyright 2008 Samtec, Inc Page 1 Summary LIFEJACK met or exceeded TIA/EIA-568-B.2-2001 Category 5e requirements for Insertion
More informationCategory 6 UTP EuroClass C ca Cables
Category 6 UTP EuroClass C ca Cables Datasheet: GD103704v1 APPLICATION Brand-Rex Cat6Plus C6U cables exceed the Category 6 performance standards. They are rated to 250MHz and are suitable for use in all
More informationlntertek Testing Services ETL SEMKO For SPORTSMAN'S MARKET, INC. Scanning Receiver Model: SP-125 FCC m: DY7RT2013 Job # Report #
lntertek Testing Services ETL SEMKO TEST REPORT For SPORTSMAN'S MARKET, INC. Scanning Receiver Model: SP-125 FCC m: DY7RT2013 Job # 3036423 Report # 30364231 Date of Testing: December 26-27, 2002 Date
More informationFCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50
FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR Dolphin CT50 MODEL NUMBER: CT50LFN IC ID: 1693B-CT50LFN REPORT NUMBER: 15U20259-E6 ISSUE DATE: JUNE 08, 2015 Prepared
More informationEMC SHIELDING EFFECTIVENESS TEST REPORT : : :
1.0 1 of 17 EMC SHIELDING EFFECTIVENESS TEST REPORT Test Specification Manufacturer Test Samples : : : MIL-DTL-83528F Specialty Silicone Products 1. SSP547-65 Silver Copper in silicone 65 shore A 2. SSP548-65
More informationTRANSMITTER MODEL: KAS-2030M
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved
More informationEMC SHIELDING EFFECTIVENESS TEST REPORT : : :
1.0 1 of 15 EMC SHIELDING EFFECTIVENESS TEST REPORT Test Specification Manufacturer Test Samples : : : MIL-DTL-83528F Specialty Silicone Products, Inc. 1. SSP-2529 DOCUMENT HISTORY REVISION ISSUE DATE
More informationEMC SHIELDING EFFECTIVENESS TEST REPORT : : :
1.0 1 of 16 EMC SHIELDING EFFECTIVENESS TEST REPORT Test Specification Manufacturer Test Samples : : : MIL-DTL-83528F Specialty Silicone Products 1. SSP502-40 Nickel Graphite in silicone 40 Shore A 2.
More informationPart Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor
Part Number: Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor Product Description Four Cat 6 23 AW G solid bare copper conductors, bonded pair polypropylene insulation,
More informationISO/IEC JTC 1/SC 25/WG 3 N 755 Date: Replaces ISO/IEC JTC 1/SC 25/WG 3 N n/a
ISO/IEC JTC 1/SC 25/WG 3 N 755 Date: 2005-05-18 Replaces ISO/IEC JTC 1/SC 25/WG 3 N n/a ISO/IEC JTC 1/SC 25/WG 3 Customer Premises Cabling Secretariat: Germany (DIN) DOC TYPE: Liaison document TITLE: Letter
More informationTSB-67. Transmission Performance Specifications for Field Testing of UTP Cabling Systems
TSB-67 Transmission Performance Specifications for Field Testing of UTP Cabling Systems Prepared by: ANSI/EIA/TIA PN-3287 Task Group on UTP Link Performance Required Field Test Parameters for TSB-67 Wire
More informationPhysical Test Setup for Impulse Noise Testing
Physical Test Setup for Impulse Noise Testing Larry Cohen Overview Purpose: Use measurement results for the EM coupling (Campbell) clamp to determine a stable physical test setup for impulse noise testing.
More informationFCC 47 CFR PART 15 SUBPART B CERTIFICATION TEST REPORT FOR a/b/g/n/ac 3X3 WLAN + Bluetooth Combo PCI-E Mini Card MODEL NUMBER: BCM94360CS
FCC 47 CFR PART 15 SUBPART B CERTIFICATION TEST REPORT FOR 802.11a/b/g/n/ac 3X3 WLAN + Bluetooth Combo PCI-E Mini Card MODEL NUMBER: BCM94360CS FCC ID: QDS-BRCM1069 IC: 4324A-BRCM1069 REPORT NUMBER: 12U14668-5
More informationwww.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-010 TEST OF PAR 38 LED LAMPS MODEL NOS. S8854 / S8861
More informationwww.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-018 TEST OF PAR 30L LED LAMPS MODEL NOS. S8814 / S8821
More informationAustralian/New Zealand Standard
AS/NZS IEC 61935.1:2006 IEC 61935-1:2005 AS/NZS IEC 61935.1:2006 Australian/New Zealand Standard Testing of balanced communication cabling in accordance with ISO/IEC 11801 Part 1: Installed cabling AS/NZS
More informationwww.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-036 TEST OF LED CANDLE LAMPS MODEL NOS. S8891 / S8894
More informationwww.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-039 TEST OF LED CANDLE LAMPS MODEL NOS. S8899 / S8903
More informationFour Cat 5e 24 AW G Bonded-Pairs solid bare copper conductors, polyolefin insulation, PVC jacket.
Part Number: 7923A Cat 5e MSHA DataTuff, (4 pr) 24 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor Product Description Four Cat 5e 24 AW G Bonded-Pairs solid bare copper conductors, polyolefin insulation,
More informationADDENDUM TEST REPORT
Page : 1 of 19 ADDENDUM TEST REPORT Test Report No. : 11707924M Applicant : TAIYO YUDEN CO., LTD. Type of Equipment : Bluetooth Smart / ANT Module Model No. : EYSHCN Test standard : EN 300 328 V2.1.1 (Except
More informationXBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042
XBee Series 2 OEM RF Module Model No.: XBEE2 Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042 In Accordance With Federal Communications Commission (FCC) Part 15, Subpart C, Section
More informationCERTIFICATION TEST REPORT
CERTIFICATION TEST REPORT Report Number. : 16U23813-E3V3 DTS Applicant : Model : FCC ID : IC : EUT Description : Test Standard(s) : APPLE, INC. 1 INFINITE LOOP CUPERTINO, CA 95014, U.S.A A1822 BCGA1822
More informationCall For Interest PoE- plus. Chris Di Minico MC Communications
Call For Interest PoE- plus Chris Di Minico MC Communications cdiminico@ieee.org 1 IEEE 802.3 CFI Powering Ethernet Devices Over Data Cabling IEEE 802.3af Web Cameras Ethernet Switch Data and Power Security
More informationGuangdong Alpha Animation and Culture Co.,Ltd. MERCEDES-BENZ SLS AMG. Model: LC ( ) Superregenerative Receiver. Report No.
Guangdong Alpha Animation and Culture Co.,Ltd. Application For Certification MERCEDES-BENZ SLS AMG Model: LC258810-8 (6000814) Superregenerative Receiver We hereby certify that the sample of the above
More informationAutomatic measuring system for LAN cables AXT & Cat 8 HF only
Picture for information only Automatic measuring system for LAN cables AXT & Cat 8 HF only The fastest measuring system on the market Checked against certified ISO 17025 standards High accuracy Easy to
More informationFCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020
FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR 2.4GHz LE MODULE MODEL NUMBER: RN4020 REPORT NUMBER: 14U17191-1 ISSUE DATE: MARCH 21, 2014
More informationNemko-CCL, Inc West Alexander Street Salt Lake City, UT
Nemko-CCL, Inc. 1940 West Alexander Street Salt Lake City, UT 84119 801-972-6146 Test Report Declaration of Conformity Test Of: MICRO-RM2.4-LB Test Specification: FCC PART 15, Subpart B ICES-003, Issue
More informationLength Restrictions in Cable Testing
Length Restrictions in Cable Testing APPLICATION NOTE INTRODUCTION Even if most of LAN cable standards, besides Cat8, use 100m as a reference length, questions arise on how to interpret results when using
More informationTest Report. Test Result: PASS
Test Report Designation : C6 A TIA/EIA68B. UTP Length :. m Temp :. Deg C Specification : CAT6 A MHZ UTP Test Date/Time : 11--16 1:1 Sample-ID-No. : GGRQ4 Customer : Rertech Drum no. :. Cable type : CAT6A
More informationFCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR THE FUEL WEB, INC. GATEWAY MODULE MODEL: GWM-P-SHRF-1 FCC ID: PX5-GWM1001
FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR THE FUEL WEB, INC. GATEWAY MODULE MODEL: GWM-P-SHRF-1 REPORT NUMBER: 04U2623-2 ISSUE DATE: APRIL 21, 2004 Prepared for THE FUEL WEB, INC. 21614
More informationTRANSMITTER Model: TX24
FCC Part 15 Subpart B and FCC Section 15.231 Test Report Page 1 of 17 FCC PART 15 SUBPART B and C TEST REPORT for TRANSMITTER Prepared for FOPRO, INC. 14 FO HOLLOW DRIVE LEWISTOWN, PENNSYLVNIA 17044 Prepared
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 Description: Banana Peel Composite - (2) Cat 5e 4-pair 24 AWG unshielded plus (2) Series 6 Coax with Duobond IV Quad shield, polyolefin insulation on the
More informationCOPPER + LWL RAW CABLES
COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation
More informationTEST REPORT. Report Number: MIN-005 Project Number: G Testing performed on the ICON Scanner OEM (Gen 1.1)
TEST REPORT Report Number: 103103871MIN-005 Project Number: G103103871 Testing performed on the ICON Scanner OEM (Gen 1.1) FCC ID: WTM-ICONNFC1 IC: 7998A-ICONNFC1 to 47 CFR Part 15.225:2017 RSS- 210, Issue
More informationCategory 7 A /Class F A Products
CATEGORY 7 A /CLASS F A PRODUCTS Category 7 A /Class F A Products Exceeding ISO/IEC category 7 A /class F A specifications, Siemonʼs fully shielded TERA endto-end cabling solution is the highest-performing,
More informationTEST REPORT. Report No.: HK (R1) Spin Master Toys Far East Ltd. Application For Certification (Original Grant) (FCC ID: PQN44438TX2G4)
TEST REPORT Spin Master Toys Far East Ltd. Application For Certification (Original Grant) () Transceiver (Supersedes report No. HK13020722-1, dated April 09, 2013.) Prepared and Checked by: Approved by:
More informationComparison of vario. ous cables & channels
Noise Immunity Performance Analysis of Screened Cab bling Systems Comparison of vario ous cables & channels Martin Rossbach, Nexans Cabling Solutions Victoria, BC, Canada May 16, 2013 Overview Definition
More informationInternational Maritime Organization (IMO) Fire Test Procedures (FTP) Code Part 5 and 6
Page 1 of 20 International Maritime Organization (IMO) Fire Test Procedures (FTP) Code Part 5 and 6 Temp-Coat 101 Project No. 100368576SAT-002.1A April 28, 2011 Prepared for: Temp-Coat Brand Products LLC
More informationA Test Lab Techno Corp. Report Number:1410FR27
Mode 5: IEEE 802.11n 2.4GHz 40MHz Link Mode 2422 2437 2452 Page 41 of 85 9 Out of Band Conducted Emissions Measurement 9.1. Limit In any 100 khz bandwidth outside the frequency band in which the spread
More informationFCC Test Report. Report No.: AGC FE01 2AAP6UB15MSKB. Attestation of Global Compliance (Shenzhen) Co., Ltd
Page 1 of 24 FCC Test Report Report No.: AGC03052141001FE01 FCC ID 2AAP6UB15MSKB PRODUCT DESIGNATION : Keyboard BRAND NAME : N/A MODEL NAME : UB-15MSKB CLIENT : Shenzhen Zowee Technology Co., Ltd. DATE
More informationFCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Superior communications. Wireless charger. Model Number: Additional Model: 06122
FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Superior communications. Wireless charger Model Number: 06121 Additional Model: 06122 FCC ID: YJW06121 Prepared for: Superior communications. 5027
More informationAdvanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)
2129.01 Advanced Compliance Solutions, Inc. 3998 FAU Blvd, Suite 310 Boca Raton, Florida 33431 (561) 961-5585 Technical Report No. 09-2067a-2 EMI Evaluation of the AMM Marketing, LLC s E-Pulse UH 900,
More informationTest report No. : M Page : 1 of 24 Issued date : June 30, 2017 RADIO TEST REPORT. Test Report No. : M
Page : 1 of 24 RADIO TEST REPORT Test Report No. : 11818213M Applicant : TAIYO YUDEN CO., LTD. Type of Equipment : Bluetooth Smart / ANT Module Model No. : EYSHSN Test standard : EN 300 328 V2.1.1 (Except
More informationTABLE OF CONTENTS SECTION TITLE PAGE. 5. LIST OF EUT, ACCESSORIES AND TEST EQUIPMENT 10 EUT and Accessory List EMI Test Equipment
Page 2 of 14 TABLE OF CONTENTS SECTION TITLE PAGE GENERAL REPORT SUMMARY 04 SUMMARY OF TEST RESULTS 04 1. PURPOSE 05 2. ADMINISTRATIVE DATA 06 2.1 Location of Testing 06 2.2 Traceability Statement 06 2.3
More informationFCC PART MEASUREMENT AND TEST REPORT FOR. Guangzhou Walkera Technology CO., LTD
FCC PART 15.249 MEASUREMENT AND TEST REPORT FOR Guangzhou Walkera Technology CO., LTD Taishi Industrial Park, Yuwoto Town, Panyu District, 511475 Guangzhou, China. FCC ID: S29WK-2801PRO Report Concerns:
More informationFCC 47 CFR PART 15 SUBPART C
FCC 47 CFR PART 15 SUBPART C Product Type Applicant Address Trade Name Model Number : Wink Relay : Quirky, Inc. : 606 W 28th St, Floor 7 New York NY 10001 United States : Wink : PRLAY-WH01 Test Specification
More informationREPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045
REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G101183506 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Date: June 6, 2013 REPORT NO. 101183506CRT-001 TEST OF ONE LED FLOOD
More informationB. Division-16 Basic Materials and Methods section apply to work specified in this section.
Section 16745 PREMISE CABLING SYSTEMS PART ONE GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification
More informationTest Report for: DBA DARE 2B DIFFERENT ENTERPRISES INC.
45000 Helm Street Suite 150 Plymouth Twp., MI 48170 Telephone: 734-582-2900 Facsimile: 734-582-2901 www.intertek.com Test Report for: DBA DARE 2B DIFFERENT ENTERPRISES INC. FIELD OF VIEW TEST One Rear
More informationOUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT Prepared for MINASKA OUTDOORS 6517 PLATTE AVENUE LINCOLN, NEBRASKA 68507 Prepared by: KYLE FUJIMOTO
More informationTEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.
TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD. Test Of: Wood & Douglas Ltd ST500 Transmitter Test Report Serial No: RFI/EMCB2/RP39403B This Test Report supersedes RFI Test Report No.: RFI/EMCB1/RP39403B
More informationTEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C
TEST REPORT For RFID READER/WRITER In conformity with FCC CFR 47 Part15 Subpart C Model: TR3XM-SD01 / TR3XM-SU01 / TR3XM-SN01 FCC ID: MK4TR3XM-SX01 Test Item: RFID READER/WRITER Report No: RY1203Z12R1
More informationFCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR PCMCIA RFID READER CARD MODEL NUMBER: MPR6000 FCC ID: NTTWJMPR6XXX REPORT NUMBER: 04U2954-3
FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR PCMCIA RFID READER CARD MODEL NUMBER: MPR6000 FCC ID: NTTWJMPR6XXX REPORT NUMBER: 04U2954-3 ISSUE DATE: NOVEMBER 22, 2004 Prepared for WJ COMUNICATIONS
More informationModel 935A Current Source Operation Manual
Model 935A Current Source Operation Manual Arbiter Systems, Inc. Paso Robles, CA 93446 U.S.A. ii Description This manual is issued for reference only, at the convenience of Arbiter Systems. Reasonable
More informationMIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to
MIL STD 461F TEST REPORT For Rugged PDA Model Number: P37B Trade Name: N/A Issued to ACA Digital Corporation 17F.,No 866-7, Zhongzheng Rd, Zhonghe City, Taipei County, 235, Taiwan, R,O,C Issued by Compliance
More informationVVM measurement with E5061B for replacing 8508A vector voltmeter. May 2013 Agilent Technologies
VVM measurement with E5061B for replacing 8508A vector voltmeter May 2013 Agilent Technologies Overview of VVM measurement with E5061B Application discussed here Measuring the phase difference (& magnitude
More informationFCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR
FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR WLAN 2X2 MIMO 802.11a/b/g/n/ac with BLUETOOTH MODEL NUMBER: P2180 REPORT NUMBER: 15U21878-E2V1
More informationREPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045
FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 Project No. G101555841 Date: March 21, 2014 REPORT NO. 101555841CRT-001 TEST OF ONE LED
More informationLevel III measurement accuracy of field testers for Twisted Pair Copper Cabling Explained in Technical Detail
Level III measurement accuracy of field testers for Twisted Pair Copper Cabling Explained in Technical Detail 1 Outline Henriecus Koeman Fluke Networks July 9, 2001 This rather technical discussion contains
More informationBill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.
098-219r2 Prepared by: Ed Armstrong Zane Daggett Bill Ham Martin Ogbuokiri Date: 07-24-98 Revised: 09-29-98 Revised again: 10-14-98 Revised again: 12-2-98 Revised again: 01-18-99 1. REQUIREMENTS FOR SPI-3
More informationTechnical Note AN
Methodology for Computation of Maximum in LTCC Low Pass Filters Purpose: The purpose of this application note is to describe the procedure used for determining power handling capability of LFCW-Series
More informationClass II Permissive Change Report
Engineering and Testing for EMC and Safety Compliance Class II Permissive Change Report Harris Corporation 221 Jefferson Ridge Parkway Lynchburg, VA 24501 Daryl Popowitch Phone: (434) 455-9527 Model: P5400
More informationTEST REPORT. : FCC Part15B Class B. Report No. JM FCC ID : K
Report No. JM10110020 TEST REPORT STANDARD : FCC Part15B Class B Applicant Kenwood Corporation 1-16-2, Hakusan, Midori-ku, Yokohama-shi, Kanagawa 226-8525 Japan Tel.: +81 45 939 6254 Testing Laboratory
More informationAMERICAN NATIONAL STANDARD
Interface Practices Subcommittee AMERICAN NATIONAL STANDARD Measurement Procedure for Noise Power Ratio NOTICE The Society of Cable Telecommunications Engineers (SCTE) / International Society of Broadband
More information