Test Report based on DIN EN ISO/IEC 17025: 2005

Size: px
Start display at page:

Download "Test Report based on DIN EN ISO/IEC 17025: 2005"

Transcription

1 Test Report based on DIN EN ISO/IEC 1725: 25 GHMT Type Approval 2 Connector Permanent Link, Copper, Class EA according ISO/IEC Ed.1. Document-no: P582a-18-E This Test Report with the measurements consists of 37 pages. GHMT AG and the customer shall grant each other an unlimited right to copy and disclose this report insofar as the measuring results and specifications published are neither altered by way of including or removing information nor changed in a way that does not correspond to the original meaning of the report.

2 Table of Contents Table of Contents...2 Revision history General statements Test Laboratory Test Date Environmental conditions during testing Test Conducted by Persons Present at Test Customer Address Responsible contact person Device under test (DUT) Description of the Components Provision Definition of the Device Under Test (DUT) Test Type Reference of testing Definition of the testing parameters Insertion loss NEXT Power sum NEXT (PS NEXT) Attenuation to crosstalk ratio at the near-end (ACR-N) Power sum ACR-N (PS ACR-N) Attenuation to crosstalk ratio at the far-end (ACR-F) Power sum ACR-F (PS ACR-F) Return loss Propagation delay Delay skew Coupling attenuation Applied Standards Applied Rules and Regulations Applied Limits Deviations None Standardised Test Procedures Testing equipment Summary GHMT AG Bexbach/Germany page 2 of 37

3 8 ANNEX: Documentation of measurements SETUP Measurement results of the NF-parameters Measurement results of the HF-parameters Measurement results of the EMC-parameters GHMT AG Bexbach/Germany page 3 of 37

4 Revision history Document number Date Content/ Changes P582a-18-E initial version GHMT AG Bexbach/Germany page 4 of 37

5 1 General statements 1.1 Test Laboratory GHMT AG In der Kolling Bexbach, Germany Phone: +49 / / Fax: +49 / / E Mail: info@ghmt.de Internet: Test Date Receipt of goods: 9. May 218 Test number: 18-CS3 Testing from: 28. May 218 until: 3. May 218 during: (23 ± 3) C 1.3 Environmental conditions during testing Ambient temperature (23 ± 3) C Relative humidity (5 ± 25)% 1.4 Test Conducted by Mr. Roman Schwoll, GHMT AG Mrs. Judith Philippi, GHMT AG 1.5 Persons Present at Test Mr. Stefan Grüner, GHMT AG (present temporarily) GHMT AG Bexbach/Germany page 5 of 37

6 2 Customer 2.1 Address OPTRONICS PLUS LIMITED Grand Millennium Plaza, Queens Road Central HONG KONG Phone: Internet: Responsible contact person OPTRONICS PLUS LIMITED Mrs. Khushbu Solanki Application Engineer Griva Digeni Avenue, Office 42 Nicosia Nicosia 1311, Cyprus Phone: Fax: khushbu.solanki@optronicsplus.net Internet: GHMT AG Bexbach/Germany page 6 of 37

7 3 Device under test (DUT) 3.1 Description of the Components The following sample(s) was/were part of the test: Data cable: Part-no: CAT6A U/UTP 23 AWG Cable OCC-6A-11-XXX Charge-no: - The cable was marked with an imprinted meter counter. Cable end A: 6m Cable end B: 96m Cable length: 9m (determined on imprinted length counter) Picture: GHMT AG Bexbach/Germany page 7 of 37

8 Connector: Part-no: CAT6A UTP Keystone Jack OKJ-6A-1-X Picture: Patch panel: Part-no: CAT6A UTP 1U 24 Port Patch Panel OPPC-6A-1-24 Picture: Condition of the sample(s): The sample(s) had no visible damages 3.2 Provision The DUT was / the specimens were... with drawn on site. The selection of the sample was neutral and unaffected by the client.... obtained by GHMT through resellers. The selection of the sample was neutral and unaffected by the client.... obtained by GHMT through the client. GHMT AG Bexbach/Germany page 8 of 37

9 3.3 Definition of the Device Under Test (DUT) According to the specifications laid down in the document ISO/IEC Ed. 1., a Permanent Link was assembled in order to conduct the test: End A Patch panel I: Connector I: Data Cable: 9m Connector II: Patch panel II: CAT6A UTP 1U 24 Port Patch Panel CAT6A UTP Keystone Jack CAT6A U/UTP 23 AWG Cable CAT6A UTP Keystone Jack CAT6A UTP 1U 24 Port Patch Panel End B Figure 1: 2-Connector Permanent Link GHMT AG Bexbach/Germany page 9 of 37

10 4 Test Type 4.1 Reference of testing Testing of transmission parameters of a 2 Connector Permanent Link according to the specifications Class EA in accordance with ISO/IEC Ed. 1.. The following parameters are part of this test: NF-parameters: Direct current (d.c.) loop resistance Direct current (d.c.) loop resistance unbalance HF-parameters: Insertion loss NEXT Power sum NEXT (PS NEXT) Attenuation to crosstalk ratio at the near-end (ACR-N) Power sum ACR-N (PS ACR-N) Attenuation to crosstalk ratio at the far-end (ACR-F) Power sum ACR-F (PS ACR-F) Return loss Propagation delay Delay skew EMC-parameters: Coupling attenuation Power sum alien NEXT (PS ANEXT) Power sum alien ACR-F (PS AACR-F) GHMT AG Bexbach/Germany page 1 of 37

11 4.2 Definition of the testing parameters Insertion loss PAIR 1 PAIR 2 Near End Far End PAIR 3 PAIR 4 Definition The attenuation is determined by the ratio of the power supplied to the port A and the measured power at the port B as specified below: a V PA [db]= 1 log PB Both the input and the output of the two-port network must be terminated with the nominal impedance. Influencing variables In case of cables, the attenuation is primarily determined by the crosssectional area and the conductivity of the copper wires. Especially in high frequency ranges, the attenuation is increased by the dielectric losses of the core insulating material. The attenuation is dependent on the length, the frequency, and the temperature. Significance A low attenuation improves the transmission reliability of the cabling system. The attenuations of cables and connecting devices are accumulative although they are largely dominated by those of the cables. GHMT AG Bexbach/Germany page 11 of 37

12 4.2.2 NEXT PAIR 1 common mode / differential mode termination Near End PAIR 2 PAIR 3 Far End common mode / differential mode termination common mode / differential mode termination PAIR 4 common mode / differential mode termination Definition The near-end crosstalk attenuation is determined by the ratio of the power supplied to the port A and the measured power at the port B as specified below: a NEXT [db]= 1 P log P Both sides of the specimen must be terminated with the nominal impedance. In the event that the sender and the receiver are located at the same end of the specimen, we are speaking of near-end crosstalk (NEXT) attenuation. A B Influencing variables In case of cables, the near-end crosstalk attenuation is primarily determined by the twisting of the cores and (if existing) the paired foil screens. The near-end crosstalk attenuation is largely dependent on the frequency and to a minor degree also on the lengths. Significance A high near-end crosstalk attenuation improves the reliability of transmissions. Within the cabling system, the reliability of transmissions is primarily determined by the component having the lowest near-end crosstalk attenuation. GHMT AG Bexbach/Germany page 12 of 37

13 4.2.3 Power sum NEXT (PS NEXT) Definition The power sum of the near-end cross-talk is defined on the basis of the ratio of the power input at the three pairs A, B and C to the power output at pair D. The power-sum NEXT value of cables can be measured by means of a phase-correlated 4-port power splitter. On the basis of the pair-to-pair NEXT measurements, the power sum can also be calculated according to the following formula: a PSNEXT [db]= 1 log 3 i1 1 -,1 i a NEXT Influencing factors The power-sum NEXT value of cables is decisively influenced by the stranding and the foil pair shield (if applicable). Power-sum NEXT strongly depends on the frequency used and only to a minor extent on the cabling length. Meaning With regard to network protocols that distribute the bi-directional data load over all four pairs, power-sum NEXT is of great importance for transmission reliability since power-sum cross-talk is expected to impair transmission via the data channel. GHMT AG Bexbach/Germany page 13 of 37

14 4.2.4 Attenuation to crosstalk ratio at the near-end (ACR-N) Definition The ratio of the level of the incoming useful signal to the noise level at the opposite end of the measured link is referred to as Attenuation-to- Cross-Talk Ratio (abbr. ACR). ACR may be interpreted as the signal-to-noise ratio with the near-end cross-talk being regarded as the interfering signal or noise. ACR [db]= a N [db]-a V [db] Calculation As agreed, the ACR value is calculated for every frequency response of the near-end cross-talk with the two relevant frequency responses of the attenuation. Alternatively, the minimum value of the ACR calculation may be allocated for every measuring point of the two attenuation values involved. The determination of the double-ended system dynamics thus results in 12 ACR frequency responses for a four-pair specimen. Meaning The ACR value is of decisive importance to system designers, system manufacturers and operators of data communications equipment since it provides immediate insight into system dynamics and system reserve. The larger the distance between the useful signal and the noise signal over the entire frequency range, the larger the infrastructural reserve Power sum ACR-N (PS ACR-N) Definition The power sum of the ACR reserve is calculated as follows: PS ACR [db] = apsnext [db] av [db] Meaning With regard to network protocols that distribute the bi-directional data load over all four pairs, power-sum ACR is of great importance for transmission reliability since cross-talk is expected to impair transmission via the data channel. GHMT AG Bexbach/Germany page 14 of 37

15 4.2.6 Attenuation to crosstalk ratio at the far-end (ACR-F) Definition The equal-level far-end cross-talk (abbr. EL FEXT) is determined by the ratio of the power measured at the remote port B to the power measured at the remote port C. The measuring signal is supplied to the near end of the cable. a ELFEXT [db]= 1 P log P B C All pairs of the EUT are terminated with their characteristic impedance. Influencing factors The EL FEXT value of cables is decisively influenced by the stranding and the foil pair shield (if applicable) Power sum ACR-F (PS ACR-F) EL FEXT strongly depends on the frequency used. Definition The power-sum EL FEXT value can be calculated on the basis of the pair-to-pair EL FEXT measurements according to the following formula: a PSELFEXT [db]= 1 log 3 i1 1 -,1 i a ELFEXT Meaning With regard to network protocols that distribute the bi-directional data load over all four pairs, power-sum EL FEXT is of great importance for transmission reliability since cross-talk is expected to impair transmission via the data channel. GHMT AG Bexbach/Germany page 15 of 37

16 4.2.8 Return loss PAIR 1 differential mode termination PAIR 2 differential mode termination Near End Far End PAIR 3 differential mode termination PAIR 4 differential mode termination Definition The return loss represents the ratio of the power supplied to the EUT to the power reflected by the EUT. a R [db] = 1 P log P input output The EUT end is terminated with the characteristic impedance in order to absorb any non-reflected power. The EUT and the test-value transmitter must have the same rated impedance in the broadband range. Influencing factors The return loss value of cables is decisively influenced by the homogeneity of the conductors and the core of the cable. Mechanical load during the manufacturing or installation of the cables may impair the return loss. The parameters return loss and characteristic impedance correlate. Meaning A high degree of return loss improves the transmission reliability. A low degree of return loss may lead to an unwanted overlap of returning signal components. GHMT AG Bexbach/Germany page 16 of 37

17 4.2.9 Propagation delay PAIR 1 PAIR 2 Near End Far End PAIR 3 PAIR 4 Definition The velocity of propagation v of cables is stated in relation to the maximum velocity of propagation of electromagnetic waves in the vacuum co. The parameter "Nominal Velocity of Propagation" (abbr. NVP) is defined as follows: NVP v co The delay is the period of time the signal requires in order to travel through a cabling link with a length of l. The delay is calculated on the basis of the NVP value (Nominal Velocity of Propagation) of the cable and the velocity of light c according to the following formula: l NVP c Influencing factors The delay of cables is decisively influenced by the dielectric loss of the core insulation material. This material-induced loss may be minimised by selecting various compounds and by varying the degree of foaming. The impact of colour addition on the NVP value is not to be neglected since the colours vary strongly in their dielectric constants, which are considerably higher than in the basic compound. GHMT AG Bexbach/Germany page 17 of 37

18 Influencing factors (continued) The velocity of propagation does not depend on the cable length and may be calculated on the basis of the measurement of the lengthdependent group delay. The reference length used for calculation is the cable length and not the lay length of the twisted pairs. Different lay length values in the four pairs lead to different NVP values. Meaning In order to ensure distortion-free signal transmission, the velocity of propagation must not fall below a lower limiting value, which is determined by the system requirements. The velocity of propagation has to be virtually independent of the frequency within the signal bandwidth in order to avoid a divergence of the spectral signal components. High-bit rate network protocols that use parallel data transmission via the four pairs, moreover, require a highly consistent velocity of propagation in order to avoid synchronisation errors. Future normative standards will define this so-called "delay skew" Delay skew Definition The delay skew of cables with a length of l marks the time difference between signals travelling along the individual transmission links at the propagation velocity vi,j. = l vi v v v i j j Influencing factors The delay skew of cables is decisively influenced by the dielectric loss of the core insulation material and the various lay length values. Meaning The delay skew will be an important parameter for a distortion-free data transmission in balanced cables in view of future network protocols. GHMT AG Bexbach/Germany page 18 of 37

19 Coupling attenuation Definition Coupling Attenuation is the relation between the transmitted power through the conductor and the maximum radiated peak power, conducted and generated by the excited common mode currents. The measurement is independent of the bandwith and shall be measured form 3MHz up to 1GHz. Influencing factors The Coupling Attenuation is primarily determined by the mechanical structure of the component. The Coupling Attenuation is very much dependent on the frequency. Meaning The better the effectiveness of the Coupling Attenuation is, the smaller is the value of the noiseresistance. GHMT AG Bexbach/Germany page 19 of 37

20 Alien Crosstalk Definition The Alien Crossttalk is the signal coupling from pairs of disturbing channel or part thereof, to disturbed pair of another channel. GHMT AG Bexbach/Germany page 2 of 37

21 5 Applied Standards 5.1 Applied Rules and Regulations ISO/IEC Ed. 1.: Information technology Generic cabling for customer premises 5.2 Applied Limits ISO/IEC Ed. 1.: Information technology Generic cabling for customer premises Note: In Chapter 8 "ANNEX: Documentation of measurements", the applied limits are diagrammed within the measurement results. 5.3 Deviations None. 5.4 None Standardised Test Procedures None. GHMT AG Bexbach/Germany page 21 of 37

22 6 Testing equipment The following testing equipment was used for the measurements: Equipment Manufacturer Stock ID Network Analyzer I Rohde & Schwarz GHMTA2 Network Analyzer II Agilent GHMTA18 LCR-Meter Agilent GHMTA34 Time-Domain-Reflectometer Tektronix GHMTA4 Reference clamp GHMT GHMTA47 Absorbing Clamp Lüthi GHMTA7 Decoupling Clamp Lüthi GHMTA71 Switch unit Novotronic GHMTA28 Coaxial probe GHMT - Schedule 1: Measurement equipment GHMT AG Bexbach/Germany page 22 of 37

23 7 Summary Customer: OPTRONICS PLUS LIMITED 181 Queens Road Central HONG KONG Description: Data Cable: CAT6A U/UTP 23 AWG Cable Part-no: OCC-6A-11-XXX Connector: CAT6A UTP Keystone Jack Part-no: OKJ-6A-1-X Patch panel: CAT6A UTP 1U 24 Port Patch Panel Part-no: OPPC-6A-1-24 Applied standards: ISO/IEC Ed. 1.: Information technology Generic cabling for customer premises Result: The sample meets the limits of the applied standards and regulations with respect to the parameters indicated above. The test results which were determined in the course of the measurement refer to the submitted specimen. Bexbach, 3. May 218 i.o. Stefan Grüner, engineer (Head of Accrediteded Test Laboratory) GHMT AG In der Kolling 13 D-6645 Bexbach GHMT AG Bexbach/Germany page 23 of 37

24 8 ANNEX: Documentation of measurements As follows the measurement results of the tested parameters defined in chapter 4.2. GHMT AG Bexbach/Germany page 24 of 37

25 8.1 SETUP HF parameters EMC parameters S11 S21 Coupling attenuation Output Power dbm dbm 7 dbm Frequency Range 1-7 MHz 1-7 MHz 3-1 MHz IF Filter 1 Hz 1 Hz 3 Hz NOP AVG Smoothing,3%,3%,3% GHMT AG Bexbach/Germany page 25 of 37

26 8.2 Measurement results of the NF-parameters 18-CS3 d.c. loop resistance Limit: 17,9 Ω PAIR 12 14,1 Ω PASS PAIR 36 13,58 Ω PASS PAIR 45 14,3 Ω PASS PAIR 78 13,92 Ω PASS DC Δ loop resistance Limit:,54 Ω Pairs 12-36,43 Ω PASS Pairs 12-45,2 Ω PASS Pairs 12-78,9 Ω PASS Pairs 36-45,45 Ω PASS Pairs 36-78,34 Ω PASS Pairs 45-78,11 Ω PASS GHMT AG Bexbach/Germany page 26 of 37

27 Attenuation [db] GHMT Type Approval 8.3 Measurement results of the HF-parameters Insertion loss Pair 12-5 Pair 36 Pair 45 Pair 78 Limit ISO/IEC Class EA GHMT AG Bexbach/Germany page 27 of 37

28 NEXT End B [db] NEXT End A [db] GHMT Type Approval NEXT (End A) Pairs Pairs Pairs Pairs Pairs Pairs Limit ISO/IEC Class EA NEXT (End B) Pairs Pairs Pairs Pairs Pairs Pairs Limit ISO/IEC Class EA GHMT AG Bexbach/Germany page 28 of 37

29 PS NEXT End B [db] PS NEXT End A [db] GHMT Type Approval PS NEXT (End A) Pair 12-1 Pair 36 Pair 45 Pair 78 Limit ISO/IEC Class EA PS NEXT (End B) Pair 12-1 Pair 36 Pair 45 Pair 78 Limit ISO/IEC Class EA GHMT AG Bexbach/Germany page 29 of 37

30 ACR End B [db] ACR End A [db] GHMT Type Approval ACR-N (End A) Pairs Pairs Pairs Pairs Pairs Pairs Limit ISO/IEC Class EA ACR-N (End B) Pairs Pairs Pairs Pairs Pairs Pairs Limit ISO/IEC Class EA GHMT AG Bexbach/Germany page 3 of 37

31 PS ACR-N End B [db] PS ACR-N End A [db] GHMT Type Approval PS ACR-N (End A) Pair 12 Pair 36-1 Pair 45 Pair 78 Limit ISO/IEC Class EA PS ACR-N (End B) Pair 12 Pair 36-1 Pair 45 Pair 78 Limit ISO/IEC Class EA GHMT AG Bexbach/Germany page 31 of 37

32 ACR-F End B [db] ACR-F End A [db] GHMT Type Approval ACR-F (End A) Pairs Pairs Pairs Pairs Pairs Pairs Limit ISO/IEC Class EA ACR-F (End B) Pairs Pairs Pairs Pairs Pairs Pairs Limit ISO/IEC Class EA GHMT AG Bexbach/Germany page 32 of 37

33 PS ACR-F End B [db] PS ACR-F End A [db] GHMT Type Approval PS ACR-F (End A) Pair 12-1 Pair 36 Pair 45 Pair 78 Limit ISO/IEC Class EA PS ACR-F (End B) Pair 12-1 Pair 36 Pair 45 Pair 78 Limit ISO/IEC Class EA GHMT AG Bexbach/Germany page 33 of 37

34 Return Loss End B [db] Return Loss End A [db] GHMT Type Approval Return loss (End A) Pair 12 Pair 36-5 Pair 45 Pair 78 Limit ISO/IEC Class EA RL information only Return loss (End B) Pair 12 Pair 36-5 Pair 45 Pair 78 Limit ISO/IEC Class EA RL information only GHMT AG Bexbach/Germany page 34 of 37

35 Delay Skew [ns] Delay [ns] GHMT Type Approval Propagation delay 8, 7, 6, 5, 4, 3, 2, Pair 12 Pair 36 1, Pair 45 Pair 78 Limit ISO/IEC Class EA, Delay skew 1, 1, 1, 1, Pairs Pairs 12-45,1 Pairs Pairs Pairs Pairs Limit ISO/IEC Class EA, GHMT AG Bexbach/Germany page 35 of 37

36 PS ANEXT [db] Coupling Attenuation [db] GHMT Type Approval 8.4 Measurement results of the EMC-parameters Coupling attenuation Coupling attenuation (All In One) Pair 12 Near End 18-CS3 1 Pair 12 Far End Pair 36 Near End Pair 36 Far End Pair 45 Near End Pair 45 Far End 13 Pair 78 Near End Pair 78 Far End 14 Evaluation Envelope (CA= 45,66 db) 15 Limit ISO/IEC Alien NEXT met by design Power sum alien NEXT (PS ANEXT) Pairs with 12 Pairs with 36-1 Pairs with 45 Pairs with 78-2 ISO/IEC GHMT AG Bexbach/Germany page 36 of 37

37 PS AACR-F [db] GHMT Type Approval Power sum alien ACR-F (PS AACR-F) Pairs with 12 Pairs with 36-1 Pairs with 45 Pairs with 78-2 ISO/IEC GHMT AG Bexbach/Germany page 37 of 37

Test Report based on DIN EN ISO/IEC 17025:2005

Test Report based on DIN EN ISO/IEC 17025:2005 Test Report based on DIN EN ISO/IEC 1725:25 GHMT Type Approval 2 Connector Permanent Link, Copper, Class E according ISO/IEC 1181-1 Ed.1. 217-11 Document-no: P4945b-18-E This Test Report with the measurements

More information

Test Report based on DIN EN ISO/IEC 17025

Test Report based on DIN EN ISO/IEC 17025 Test Report based on DIN EN ISO/IEC 17025 GHMT PREMIUM Verification Program Recertification Connector, Copper, Category 6A ISO/IEC 11801 Ed.2.2 This Test Report with the measurements consists of 28 pages.

More information

Protocol based on DIN EN ISO/IEC 17025

Protocol based on DIN EN ISO/IEC 17025 Protocol based on DIN EN ISO/IEC 17025 GHMT Informative Measurement 2 Connector Channel (30m), Copper, Class II according ISO/IEC/TR 11801-9901: 2014 Document-no.: I875a-16-E This Test Report with the

More information

n Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs.

n Proper pin termination at each end n Continuity to the remote end n Shorts between any two or more conductors n Transposed pairs: n Crossed pairs. INTRODUCTION Structured Cabling or data cabling (also known Local Area Network or LAN Cabling) is increasing in its deployment for business, commercial and residential use to carry signaling for networks

More information

DELTA Test Report. Certification testing of generic cabling products: Unscreened channel, Class E, 4 connector model. Performed for Sterling

DELTA Test Report. Certification testing of generic cabling products: Unscreened channel, Class E, 4 connector model. Performed for Sterling DELTA Test Report TEST Reg. no. 19 Certification testing of generic cabling products: Unscreened channel, Class E, 4 connector model Performed for Sterling DANAK-19/16909 Project no.: T213173-01 Page 1

More information

Qualification testing of 100 ohm shielded channel, Class EA. Performed for Tyco Electronics Raychem N.V.

Qualification testing of 100 ohm shielded channel, Class EA. Performed for Tyco Electronics Raychem N.V. We help ideas meet the real world DELTA Test Report DANAK TEST Reg. no. 19 Qualification testing of 100 ohm shielded channel, Class EA Performed for Tyco Electronics Raychem N.V. DANAK-19J1636 Project

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61935-1 Edition 3.0 2009-07 Specification for the testing of balanced and coaxial information technology cabling Part 1: Installed balanced cabling as specified in ISO/IEC 11801

More information

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables. 098-219r2 Prepared by: Ed Armstrong Zane Daggett Bill Ham Martin Ogbuokiri Date: 07-24-98 Revised: 09-29-98 Revised again: 10-14-98 Revised again: 12-2-98 Revised again: 01-18-99 1. REQUIREMENTS FOR SPI-3

More information

Independent Testing - For End User Confidence

Independent Testing - For End User Confidence Independent Testing - For End User Confidence ELECTRICAL TRANSMISSION PERFORMANCE TESTING OF SCREENED CATEGORY 6 ISO/IEC, EN & TIA/EIA CONNECTING HARDWARE ACCORDING TO REQUIREMENTS OF 2ND EDITION ISO/IEC

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication ISO/IEC TR 11801-9901 TECHNICAL REPORT Edition 1.0 2014-10 colour inside Information technology Generic cabling for customer premises Part 9901: Guidance for balanced cabling in support of at least 40

More information

1) The addition of TCL and ELTCTL requirements to Category 6

1) The addition of TCL and ELTCTL requirements to Category 6 Subject 444 TO: SUBJECT: 455 East Trimble Road San Jose, CA 95131 July 28, 2008 Subscribers to UL s Listing and Verification Services for Communications Cable (DUZX) Revised Test and Follow-Up Service

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL REPORT ISO/IEC TR 11801-9901 Edition 1.0 2014-10 colour inside Information technology Generic cabling for customer premises Part 9901: Guidance for balanced cabling in support of at least 40

More information

NETWORK CONNECTIVITY SYSTEMS

NETWORK CONNECTIVITY SYSTEMS NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation

More information

Chapter 12: Transmission Lines. EET-223: RF Communication Circuits Walter Lara

Chapter 12: Transmission Lines. EET-223: RF Communication Circuits Walter Lara Chapter 12: Transmission Lines EET-223: RF Communication Circuits Walter Lara Introduction A transmission line can be defined as the conductive connections between system elements that carry signal power.

More information

Cabling Ad Hoc Cat 5e Measurements

Cabling Ad Hoc Cat 5e Measurements Cabling Ad Hoc Cat 5e Measurements Larry Cohen Solarflare Communications 1 Overview Cabling Ad Hoc Test Plan Measurement One Cat 5e horizontal cable sample, four test channel configurations characterized

More information

TSB-67. Transmission Performance Specifications for Field Testing of UTP Cabling Systems

TSB-67. Transmission Performance Specifications for Field Testing of UTP Cabling Systems TSB-67 Transmission Performance Specifications for Field Testing of UTP Cabling Systems Prepared by: ANSI/EIA/TIA PN-3287 Task Group on UTP Link Performance Required Field Test Parameters for TSB-67 Wire

More information

Category 6 UTP EuroClass C ca Cables

Category 6 UTP EuroClass C ca Cables Category 6 UTP EuroClass C ca Cables Datasheet: GD103704v1 APPLICATION Brand-Rex Cat6Plus C6U cables exceed the Category 6 performance standards. They are rated to 250MHz and are suitable for use in all

More information

XX.7 Link segment characteristics

XX.7 Link segment characteristics XX.7 Link segment characteristics 10GBASE-T is designed to operate over a 4-pair balanced cabling system. Each of the four pairs supports an effective data rate of 2500 Mbps in each direction simultaneously.

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD IEC 61935-1 Edition 4.0 2015-12 colour inside Specification for the testing of balanced and coaxial information technology cabling Part 1: Installed balanced cabling as specified

More information

Copper and Fiber Optic Cables

Copper and Fiber Optic Cables Copper and Fiber Optic Cables Pietro Nicoletti piero[at]studioreti.it Cables-Engl - 1 P. Nicoletti: see note pag. 2 Copyright note These slides are protected by copyright and international treaties. The

More information

TR-285 Broadband Copper Cable Models

TR-285 Broadband Copper Cable Models TECHNICAL REPORT TR-285 Broadband Copper Cable Models Issue: 1 Amendment 1 Issue Date: March 2017 The Broadband Forum. All rights reserved. Notice The Broadband Forum is a non-profit corporation organized

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

Independent 3rd Party Test Study for 10GBE. New insights for end users and consultants

Independent 3rd Party Test Study for 10GBE. New insights for end users and consultants Independent 3rd Party Test Study for 10GBE New insights for end users and consultants Content Why & Who & What & How? Qualification Testing Study Results Study Conclusions Unmasking of UTP fairytales Where

More information

ECE 528 Understanding Power Quality

ECE 528 Understanding Power Quality ECE 528 Understanding Power Quality http://www.ece.uidaho.edu/ee/power/ece528/ Paul Ortmann portmann@uidaho.edu 208-733-7972 (voice) Lecture 41 1 Today Wiring for communications Decibels Coupling Avoiding

More information

AMP NETCONNECT Category 6 System

AMP NETCONNECT Category 6 System AMP NETCONNECT Category 6 System 2 How Did We Get Here? Basic Cabling Structure Component Specifications Link/Channel Specifications Additional Structure Options EIA/TIA TSB36 EIA/TIA 568 TIA/EIA TSB40

More information

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires

More information

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN OVERVIEW Purpose: Examine the common-mode and differential RF ingress levels of 4-pair UTP, F/UTP, and F/FTP cables at an (RJ45) MDI port

More information

Physical Test Setup for Impulse Noise Testing

Physical Test Setup for Impulse Noise Testing Physical Test Setup for Impulse Noise Testing Larry Cohen Overview Purpose: Use measurement results for the EM coupling (Campbell) clamp to determine a stable physical test setup for impulse noise testing.

More information

Automatic measuring system for LAN cables AXT & Cat 8 HF only

Automatic measuring system for LAN cables AXT & Cat 8 HF only Picture for information only Automatic measuring system for LAN cables AXT & Cat 8 HF only The fastest measuring system on the market Checked against certified ISO 17025 standards High accuracy Easy to

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2 Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded

More information

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation) ACR (Attenuation to Crosstalk Ratio) The distance between the wanted signal and the interfering signal (ACR) is an important factor for the transmission quality. To ensure a faultless transmission, the

More information

Cable Testing TELECOMMUNICATIONS AND NETWORKING

Cable Testing TELECOMMUNICATIONS AND NETWORKING Cable Testing TELECOMMUNICATIONS AND NETWORKING Analog Signals 2 Digital Signals Square waves, like sine waves, are periodic. However, square wave graphs do not continuously vary with time. The wave holds

More information

Superiorr Essex. Suite 150

Superiorr Essex. Suite 150 3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com March 2, 216 Test Report Number: 1246639CRT-14 Project Number: 1246639 Legrand North America 125 Eugene

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic

More information

Automatic measuring system for xdsl & LAN cables (100 MHz) Designed to measure all types of telecom and special cables

Automatic measuring system for xdsl & LAN cables (100 MHz) Designed to measure all types of telecom and special cables Indicative picture Phoenix 1004 DT Automatic measuring system for xdsl & LAN cables (100 MHz) Designed to measure all types of telecom and special cables Compliant to all major national standards for telephone,

More information

Media. Twisted pair db/km at 1MHz 2 km. Coaxial cable 7 db/km at 10 MHz 1 9 km. Optical fibre 0.2 db/km 100 km

Media. Twisted pair db/km at 1MHz 2 km. Coaxial cable 7 db/km at 10 MHz 1 9 km. Optical fibre 0.2 db/km 100 km Media Attenuation Repeater spacing Twisted pair 10-12 db/km at 1MHz 2 km Coaxial cable 7 db/km at 10 MHz 1 9 km Optical fibre 0.2 db/km 100 km conniq.com provides an excellent tutorial on physical media.

More information

Channel Characteristics and Impairments

Channel Characteristics and Impairments ELEX 3525 : Data Communications 2013 Winter Session Channel Characteristics and Impairments is lecture describes some of the most common channel characteristics and impairments. A er this lecture you should

More information

Copper Lines and High Speed

Copper Lines and High Speed Copper Lines and High Speed Application Note 52 Line quality is no coincidence Testing transmission lines for ADSL Test Solutions with the PSM-137 Selective Level Test Set Contents Testing transmission

More information

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH FIGURE CONSTRUCTION Inner conductor CCA Φ 0.50±0.01mm Insulation Solid HDPE Φ 0.90±0.05mm Color 1 Blue & White/ Blue 2 Orange & White/ Orange 3 Green & White/

More information

University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium

University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium As of June 18 th, 2003 the Gigabit Ethernet Consortium Clause 40 Physical Medium Attachment Conformance Test Suite Version

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General Install & Go SMARTen (Cat.6A) STP Trunk General Cat 8 Filler Cat.6A U/FTP Horizontal cables (x6) Fan-Out Cables Cat.6A STP Keystones TRUNK CABLE SECTION VIEW Trunk Isometric Front View RiT s Copper Install

More information

A Few (Technical) Things You Need To Know About Using Ethernet Cable for Portable Audio

A Few (Technical) Things You Need To Know About Using Ethernet Cable for Portable Audio A Few (Technical) Things You Need To Know About Using Ethernet Cable for Portable Audio Rick Rodriguez June 1, 2013 Digital Audio Data Transmission over Twisted-Pair This paper was written to introduce

More information

Information technology. Generic cabling systems, General requirements

Information technology. Generic cabling systems, General requirements KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.

More information

Category 6 A F/FTP Euroclass C ca Cables

Category 6 A F/FTP Euroclass C ca Cables Category 6 A F/FTP Euroclass C ca s Datasheet: GD103266v2 APPLICATION The Brand-Rex AC6F/FTP C ca cables are compliant with the European Construction Products Regulation, achieving Euroclass level C ca

More information

technical bulletin UTP vs STP Shielded data cables make the grade Unshielded data cables reach the limits of their performance

technical bulletin UTP vs STP Shielded data cables make the grade Unshielded data cables reach the limits of their performance technical bulletin Data communication technology 12/2015 UTP vs STP Shielded data cables make the grade Unshielded data cables reach the limits of their performance Business Unit Datacom LEONI Kerpen GmbH

More information

125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860)

125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860) 3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com December 16, 214 Test Report Number: 33592CRT-137 Project Number: 33592 Legrand North America Superior

More information

Comparison of vario. ous cables & channels

Comparison of vario. ous cables & channels Noise Immunity Performance Analysis of Screened Cab bling Systems Comparison of vario ous cables & channels Martin Rossbach, Nexans Cabling Solutions Victoria, BC, Canada May 16, 2013 Overview Definition

More information

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies Test Report Prepared for: Becker Avionics, Inc Model: TG660-50 Description: Aeronautical basestation radio used for emergencies Serial Number: 10001, 10002 FCC ID: 2AHX9TG660 To FCC Part 87 Date of Issue:

More information

Test Report. Test Result: PASS

Test Report. Test Result: PASS Test Report Designation : C6 A TIA/EIA68B. UTP Length :. m Temp :. Deg C Specification : CAT6 A MHZ UTP Test Date/Time : 11--16 1:1 Sample-ID-No. : GGRQ4 Customer : Rertech Drum no. :. Cable type : CAT6A

More information

SECTION BUILDING WIRE AND CABLE

SECTION BUILDING WIRE AND CABLE SECTION 260519 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Building wire and cable. 2. Wiring connectors and connections. B. RELATED SECTIONS 1. Section 26 05 53 Electrical Identification. 2. Section

More information

Design and experimental realization of the chirped microstrip line

Design and experimental realization of the chirped microstrip line Chapter 4 Design and experimental realization of the chirped microstrip line 4.1. Introduction In chapter 2 it has been shown that by using a microstrip line, uniform insertion losses A 0 (ω) and linear

More information

GIGABIT ETHERNET CONSORTIUM

GIGABIT ETHERNET CONSORTIUM GIGABIT ETHERNET CONSORTIUM Clause 126 2.5G/5GBASE-T PMA Test Suite Version 1.2 Technical Document Last Updated: March 15, 2017 2.5, 5 and 10 Gigabit Ethernet Testing Service 21 Madbury Road, Suite 100

More information

As the responsible EMC Engineer, I hereby declare that the equipment tested as specified in this report conforms to the requirements indicated.

As the responsible EMC Engineer, I hereby declare that the equipment tested as specified in this report conforms to the requirements indicated. MOBILE DEVICES BUSINESS PRODUCT SAFETY AND COMPLIANCE EMC LABORATORY EMC TEST REPORT Test Report Number 24262-1 WLAN Report Date December 17, 2010 The test results contained herein relate only to the model(s)

More information

125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860)

125 Eugene O Neill Drive 6120 Powers Ferry Road New London, CT Suite 150 Ph (860) Atlanta, GA Fax (860) 3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com December 16, 214 Test Report Number: 33592CRT-136 Project Number: 33592 Legrand North America Superior

More information

Test report number CRT-001b Project number CRT-001b

Test report number CRT-001b Project number CRT-001b 3933 US Route 11 Cortland, NY 13 Telephone: (7) 3-6711 Facsimile: (7) 8-39 www.intertek.com July 24, 215 Nexans Cabling Solutions Alsembergsesteenweg 2, b3 B-151 Buizingen BELGIUM Test report number 12193693CRT-1b

More information

2.5G/5G/10G ETHERNET Testing Service

2.5G/5G/10G ETHERNET Testing Service 2.5G/5G/10G ETHERNET Testing Service Clause 126 2.5G/5GBASE-T PMA Test Plan Version 1.3 Technical Document Last Updated: February 4, 2019 2.5, 5 and 10 Gigabit Ethernet Testing Service 21 Madbury Road,

More information

University of Pennsylvania Department of Electrical and Systems Engineering ESE319

University of Pennsylvania Department of Electrical and Systems Engineering ESE319 University of Pennsylvania Department of Electrical and Systems Engineering ESE39 Laboratory Experiment Parasitic Capacitance and Oscilloscope Loading This lab is designed to familiarize you with some

More information

Influence of Aging Effects on Cables. Influence of Aging Effects on RF behavior Including Mode Conversion of STP and UTP Cables

Influence of Aging Effects on Cables. Influence of Aging Effects on RF behavior Including Mode Conversion of STP and UTP Cables Influence of Aging Effects on RF behavior Including Mode Conversion of STP and UTP Cables Josef Ohni Research Engineer Philipp Numberger Development Engineer 2017 IEEE-SA Ethernet & IP @ Automotive Technology

More information

Methods for Testing Impulse Noise Tolerance

Methods for Testing Impulse Noise Tolerance Methods for Testing Impulse Noise Tolerance May,6,2015 Larry Cohen Overview Purpose: Describe some potential test methods for impulse noise tolerance What we will cover in this presentation: Discuss need

More information

Level III measurement accuracy of field testers for Twisted Pair Copper Cabling Explained in Technical Detail

Level III measurement accuracy of field testers for Twisted Pair Copper Cabling Explained in Technical Detail Level III measurement accuracy of field testers for Twisted Pair Copper Cabling Explained in Technical Detail 1 Outline Henriecus Koeman Fluke Networks July 9, 2001 This rather technical discussion contains

More information

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4 Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS IEC 61935.1:2006 IEC 61935-1:2005 AS/NZS IEC 61935.1:2006 Australian/New Zealand Standard Testing of balanced communication cabling in accordance with ISO/IEC 11801 Part 1: Installed cabling AS/NZS

More information

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR550004 TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR NO. 174001 EDITION 2.1 September 3 rd, 2018 Nippon Telegraph and

More information

Custom Interconnects Fuzz Button with Hardhat Test Socket/Interposer 1.00 mm pitch

Custom Interconnects Fuzz Button with Hardhat Test Socket/Interposer 1.00 mm pitch Custom Interconnects Fuzz Button with Hardhat Test Socket/Interposer 1.00 mm pitch Measurement and Model Results prepared by Gert Hohenwarter 12/14/2015 1 Table of Contents TABLE OF CONTENTS...2 OBJECTIVE...

More information

TEST REPORT... 1 CONTENT...

TEST REPORT... 1 CONTENT... CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMF RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 5 4 EMI TEST... 6 4.1 DISTURBANCE VOLTAGE ON MAINS TERMINALS ( KHZ- MHZ)...

More information

1.0 Job Description 1.1 Client Information This EUT has been tested at the request of: Company: Spectronic Denmark A/S Contact: John Herlev Telephone: 011 45 863-87-222 Fax: 011 45 863-87-704 Email: jhe@spectronic-denmark.com

More information

Guide on Implementation of Requirements of the Common EPS

Guide on Implementation of Requirements of the Common EPS Annex III to Ref. Ares(2015)3438296-19/08/2015 MoU regarding Harmonisation of a Charging Capability for Mobile Phones, June 5th, 2009 Date: Dec 15, 2011 Foreword: Guide on Implementation of Requirements

More information

TEST REPORT. DANAK Reg. no. 19. Electrical performance testing of: Connecting Hardware according to IEC

TEST REPORT. DANAK Reg. no. 19. Electrical performance testing of: Connecting Hardware according to IEC Page 1 of 12 2 Appendices TEST REPORT DANAK Reg. no. 19 DELTA Danish Electronics, Light & Acoustics Venlighedsvej 4 DK-2970 Hørsholm Denmark Tel. (+45) 45 86 77 22 Fax (+45) 45 86 58 98 www.delta.dk Electrical

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

EMC-PERFORMANCE OF BALANCED (SYMMETRICAL) CABLES

EMC-PERFORMANCE OF BALANCED (SYMMETRICAL) CABLES EMC-PERFORMANCE OF BALANCED (SYMMETRICAL) CABLES MEASURING PROCEDURE TO MEASURE THE "COUPLING ATTENUATION" OF SCREENED TWISTED PAIRS Thomas Hähner, Alcatel Kabel, Nürnberg, Bernhard Mund bedea Berkenhoff

More information

Cable Type 100. CAI Certification Specification

Cable Type 100. CAI Certification Specification Cable Type 100 CAI Certification Specification Ref: CAI-007-C / 100 / 12-2016 Confederation of Aerial Industries Ltd Communications House 41a Market Street WATFORD Herts WD18 0PN Tel: 01923 803030 Fax:

More information

Product Bulletin. Belden DataTwist 4800 Cables

Product Bulletin. Belden DataTwist 4800 Cables Product Bulletin PB 296 Belden DataTwist 4800 Cables DataTwist 4800 UTP Cables provide significant headroom and robust data transmission performance for today s most demanding applications. The cables

More information

CAT 5e UTP Cable: NETSET BOX [305m], indoor

CAT 5e UTP Cable: NETSET BOX [305m], indoor Code: E08_05 CAT 5e UTP Cable: NETSET BOX [05m], indoor NETSET BOX UTP 5e Ethernet cable far exceeds the requirements for Category 5e twisted pair cables. View of the cable box - inside 05m of the cable.

More information

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS Page 1 of 49 TESTT REPORT For Applicant : ACOUSTMAX INTERNATIONAL CO.., LTD Unit D16/F Cheuk Nang Plaza 250 Hennessy Road Address : WanchaiHongKong Product Name : Monster GLO Model Name : MNGLO-S, MNGLO-L,MNGLO-M,MNGLO-Mini

More information

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29 FCC REPORT Applicant: Dongguan Hele Electronics Co., Ltd. Address of Applicant: Dalingya Industrial Zone, Daojiao Town, Dongguan City, Guangdong China Equipment Under Test (EUT) Product Name: Model No.:

More information

Cable Type 125. CAI Certification Specification

Cable Type 125. CAI Certification Specification Cable Type 125 CAI Certification Specification Ref: CAI-008-C / 125 / 12-2016 Confederation of Aerial Industries Ltd Communications House 41a Market Street WATFORD Herts WD18 0PN Tel: 01923 803030 Fax:

More information

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020 FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR 2.4GHz LE MODULE MODEL NUMBER: RN4020 REPORT NUMBER: 14U17191-1 ISSUE DATE: MARCH 21, 2014

More information

IEEE RTPGE Automotive Datalinks over Twisted Quad Cabling

IEEE RTPGE Automotive Datalinks over Twisted Quad Cabling Automotive Datalinks over Twisted Quad Cabling T. Müller, G. Armbrecht, S. Kunz Rosenberger Hochfrequenztechnik GmbH & Co. KG Outline Automotive Datalinks over Twisted Quad Cabling Twisted Quad fundamentals

More information

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR Prepared for Address : SHENZHEN EAGLE TECHNOLOGY CO., LTD : A FIoor 1 BIdg.14, Changfeng

More information

Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy. Part 3:

Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy. Part 3: INTERNATIONAL STANDARD ISO 11452-3 Third edition 2016-09-01 Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy Part 3: Transverse electromagnetic

More information

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob For Caterpillar Inc. 330 S.W. Adams Street Peoria, IL 61630 P.O. Number JBL 11260 Date Tested May 11, 2016 Test Personnel Mark Longinotti

More information

Telecommunication Wiring Questions

Telecommunication Wiring Questions Telecommunication Wiring Questions 1. is the process of modifying a carrier frequency in rhythm to the audio frequency. A, Modulation B. Amplitude C. Change of phase D. Interference 2. is the property

More information

Broadband Current Probe Series Operation Manual

Broadband Current Probe Series Operation Manual Broadband Current Probe Series Operation Manual 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 OPERATING INSTRUCTIONS 5 FORMULAS 6 MAINTENANCE 7 WARRANTY 8 2 INTRODUCTION CURRENT PROBE SPECIFICATIONS

More information

SERIES K: PROTECTION AGAINST INTERFERENCE

SERIES K: PROTECTION AGAINST INTERFERENCE International Telecommunication Union ITU-T K.49 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (12/2005) SERIES K: PROTECTION AGAINST INTERFERENCE Test requirements and performance criteria for voice

More information

10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs

10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs 10 Mb/s Single Twisted Pair Ethernet Conducted Immunity Steffen Graber Pepperl+Fuchs IEEE P802.3cg 10 Mb/s Single Twisted Pair Ethernet Task Force 1/15/2019 1 Content EMC Generator Noise Amplitude Coupling-Decoupling-Network

More information

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment Christian Suttner*, Stefan Tenbohlen Institute of Power Transmission and High Voltage Technology (IEH), University of

More information

1000BASE-T1 EMC Test Specification for Common Mode Chokes

1000BASE-T1 EMC Test Specification for Common Mode Chokes IEEE 1000BASE-T1 EMC Test Specification for Common Mode Chokes Version 1.0 Author & Company Dr. Bernd Körber, FTZ Zwickau Title 1000BASE-T1 EMC Test Specification for Common Mode Chokes Version 1.0 Date

More information

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave. 20 Amplifiers 83020A microwave 875A microwave 8308A microwave 8307A microwave 83006A microwave 8705C preamplifier 8705B preamplifier 83050/5A microwave The Agilent 83006/07/08/020/050/05A test s offer

More information

IEC Electrical fast transient / Burst immunity test

IEC Electrical fast transient / Burst immunity test CONDUCTED RF EQUIPMENT POWER AMPLIFIERS IEC 61000-4-4 Electrical fast transient / Burst immunity test IEC 61000-4-4 Electrical fast transient / Burst immunity test Markus Fuhrer Phenomenom open a contact

More information

Helios Automatic measuring system for telephone cables. Designed to measure all types of telecom cables

Helios Automatic measuring system for telephone cables. Designed to measure all types of telecom cables Automatic measuring system for telephone cables Helios 10104 Indicative picture Designed to measure all types of telecom cables Checked against certified ISO 17025 standards (LF) Automatic calibration

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 11452-4 Fourth edition 2011-12-15 Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy Part 4: Harness excitation

More information

MEASUREMENTS OF COUPLING THROUGH BRAIDED SHIELD VIA NEW CONDUCTED IMMUNITY TECH- NIQUE

MEASUREMENTS OF COUPLING THROUGH BRAIDED SHIELD VIA NEW CONDUCTED IMMUNITY TECH- NIQUE Progress In Electromagnetics Research C, Vol. 11, 61 68, 2009 MEASUREMENTS OF COUPLING THROUGH BRAIDED SHIELD VIA NEW CONDUCTED IMMUNITY TECH- NIQUE M. Ghassempouri College of Electrical Engineering Iran

More information

Results You Can Count On

Results You Can Count On 20 khz to 300 MHz Noise Generator for Realistic Gfast Testing Up to 24 Independent Noise Ports Gfast technology promises to bring a wealth of new opportunities to Service Providers as well as manufacturers

More information

Protection of fixed monitoring stations against interference from nearby or strong transmitters

Protection of fixed monitoring stations against interference from nearby or strong transmitters Recommendation ITU-R SM.575-2 (10/2013) Protection of fixed monitoring stations against interference from nearby or strong transmitters SM Series Spectrum management ii Rec. ITU-R SM.575-2 Foreword The

More information

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated

More information

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed

More information

High Speed Characterization Report

High Speed Characterization Report PCRF-064-1000-SMA-P-1 Mated with: PCIE-XXX-02-X-D-TH and SMA-J-P-X-ST-TH1 Description: Cable Assembly, Low Loss Microwave Coax, PCI Express Breakout Samtec, Inc. 2005 All Rights Reserved Table of Contents

More information

Coupling attenuation and EMC considerations Draft 1.2 Comments #363 and #364

Coupling attenuation and EMC considerations Draft 1.2 Comments #363 and #364 Coupling attenuation and EMC considerations Draft 1.2 Comments #363 and #364 Dieter Schicketanz Reutlingen University Page 1 Due to measurement implications CISPR divided the frequency range in: Below

More information

Some considerations concerning alien crosstalk Dr.-Ing. J.-H. (Jo) Walling Consultant Beaconsfield, P.Q. Canada

Some considerations concerning alien crosstalk Dr.-Ing. J.-H. (Jo) Walling Consultant Beaconsfield, P.Q. Canada Some considerations concerning alien crosstalk Dr.-Ing. J.-H. (Jo) Walling Consultant Beaconsfield, P.Q. Canada jo.walling@sympatico.ca 0. Summary Contrary to the simplified perception about alien crosstalk,

More information