TEST REPORT. : The submitted samples complied with the above EMC standards. TRF No.: AS NZS (2012)-b

Size: px
Start display at page:

Download "TEST REPORT. : The submitted samples complied with the above EMC standards. TRF No.: AS NZS (2012)-b"

Transcription

1

2 TEST REPORT Applicant Name & Address Manufacturing Site Sample Description Product Model No. : Shenzhen SOFARSOLAR Co., Ltd. 3A-1, Huake Building, East Technology Park, Qiaoxiang Road, Nanshan District, Shenzhen, China : Suga Networks Equipment (Shenzhen) Co., Ltd. Suga High-tech Industrial Park, No 8, Fulong Road, Sanzhong, Qingxi Town,Dongguan, Guangdong,China : Solar Inverter : SOFAR 30000TL-Sx, SOFAR 33000TL-Sx, SOFAR 40000TL-Sx (x=0-2) Electrical Rating : See page 5 Date Received : 25 Sep., 2015 Date Test Conducted : 26 Sep., Sep.,2015 Test standards : AS/NZS : 2012 Test Result Conclusion : Pass : The submitted samples complied with the above EMC standards. Remark : Effective date: 12 May 2015 **************************************End of age*************************************** Prepared and Checked By: Approved By: Guitar Huang Project Engineer Intertek Guangzhou Signature Strong Yao Asst. Manager Intertek Guangzhou 05 November 2015 Date This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. The test report only allows to be revised within three years from its original issued date unless further standard or the requirement was noticed. Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD Guangzhou, China Tel / Fax: / Page 1 of 28

3 CONTENT TEST REPORT... 1 CONTENT TEST RESULTS SUMMARY EMC RESULTS CONCLUSION LABORATORY MEASUREMENTS EMI TEST EMISSION LOW VOLTAGE AC MAINS PORT (CONDUCTED EMISSION) Used Test Equipment Block Diagram of Test Setup Test Setup and Procedure Test Data Measurement Uncertainty EMISSION TELECOMMUNICATIONS/NETWORK PORT EMISSION LOW VOLTAGE AC MAINS PORT (CLICKS) EMISSION- ENCLOSURE PORT (30 MHZ 1000 MHZ) Used Test Equipment Block Diagram of Test Setup Test Setup and Procedure Test Curve & Test Data Measurement uncertainty EMISSION ENCLOSURE PORT (1 GHZ 6 GHZ) APPENDIX I - PHOTOS OF TEST SETUP APPENDIX II- PHOTOS OF EUT Page 2 of 28

4 1 TEST RESULTS SUMMARY Test Item Standard Result Emission Low voltage AC mains port (Conducted emission) AS/NZS : 2012 Reference: CISPR :2008 Emission Low voltage AC mains port (Clicks) AS/NZS : 2012 Reference: CISPR 14-1: 2005 Emission Telecommunications/network port AS/NZS : 2012 Reference: CISPR 22: 2008 Emission Enclosure port (30 MHz 1000 MHz) AS/NZS : 2012 Reference: CISPR :2006 Emission Enclosure port (1 GHz 6 GHz) AS/NZS : 2012 Reference: CISPR :2006 Remark: 1. The symbol N/A in above table means Not Applicable. 2. When determining the test results, measurement uncertainty of tests has been considered. Pass N/A N/A Pass N/A Page 3 of 28

5 2 EMC Results Conclusion (with Justification) We tested the Solar Inverter, Model: SOFAR 30000TL-Sx, SOFAR 33000TL-Sx, SOFAR 40000TL-Sx (x=0-2) to determine if it was in compliance with the relevant standard as marked on the Test Results Summary. We found that the unit met the requirement of AS/NZS standard when tested as received. The worst case s test data was presented in this test report. Since all the models have identical mechanical and electrical construction except some parameter of the software architecture in order to control the max output power. And refer to the following table for details. Model DC surge arrester AC surge arrester SOFAR30000TL- S0 SOFAR33000TL- S0 SOFAR 40000TL- S0 SOFAR30000TL- S1 SOFAR33000TL- S1 SOFAR 40000TL- S1 SOFAR30000TL- S2 SOFAR33000TL- S2 SOFAR 40000TL- S2 denote incorporating this component Model Heat-dissipating methods SOFAR 40000TL-Sx, SOFAR 33000TL-Sx With two Fans SOFAR 30000TL-Sx Natural cooling Therefore we performed the tests which shown in summary table on model SOFAR 33000TL-Sx and SOFAR 40000TL-Sx The production units are required to conform to the initial sample as received when the units are placed on the market. Page 4 of 28

6 Rating: Maximum d.c. input voltage: 1000 V Input voltage range: V MPPT voltage range: V (for SOFAR 40000TL-Sx); V(for SOFAR 30000TL-Sx, SOFAR 33000TL-Sx) Max. input current: 2 32 A (for SOFAR 30000TL-Sx); 2 35 A (for SOFAR 33000TL-Sx); 2 35 A (for SOFAR 40000TL-Sx) Max. PV Isc: 2 40 A (for SOFAR 30000TL-Sx); 2 40 A (for SOFAR 33000TL-Sx); 2 40 A (for SOFAR 40000TL-Sx) Nominal output voltage: 3/N/PE230V/400Vac (for SOFAR 30000TL-Sx, SOFAR 33000TL-Sx); 3/PE/480Vac(for SOFAR 40000TL-Sx) Max. output current: 3 43 A (for SOFAR 30000TL-Sx); 3 48A (for SOFAR 33000TL-Sx); 3 48 A (for SOFAR 40000TL-Sx) Nominal frequency: 50 Hz Max. output power: VA(for SOFAR 30000TL-Sx); VA (for SOFAR 33000TL-Sx); VA (for SOFAR 40000TL-Sx) Ingress protection: IP65 Operating temperature range: -25~+60 Page 5 of 28

7 3 LABORATORY MEASUREMENTS Configuration Information Equipment Under Test (EUT): Model: Solar Inverter SOFAR 33000TL-Sx, SOFAR 40000TL-Sx Serial No. Support Equipment: Not Labeled N/A Internal frequency of the EUT: <108MHz MHz MHz >1000MHz Rated Voltage: See page 5 Condition of Environment: Temperature : 22~28 C Relative Humidity: 35~60% Atmosphere Pressure 86~106kPa Notes: 1. The EMI measurements had been made in the operating mode producing the largest emission in the frequency band being investigated consistent with normal applications. An attempt had been made to maximize the emission by varying the configuration of the EUT. 2. Test Location: All tests were performed at: CCIC Southern Electronic Product Testing(Shenzhen) Co.,Ltd. Electronic Testing Building,Shahe Road,Xili,Nanshan District,Shenzhen.China Page 6 of 28

8 4 EMI TEST 4.1 Emission Low voltage AC mains port (Conducted emission) Test Result: Pass Used Test Equipment Equipment No. Equipment Model Manufacturer A EMI receiver ESCI R&S A LISN NNLK8130 Schwarzbeck Block Diagram of Test Setup AC power source 50Ω terminator TRANSFORMER AMN EUT AE TEST RECEIVER Passive voltage Test Setup and Procedure The EUT was set to achieve the maximum emission level. The mains terminal disturbance voltage was measured with the EUT in a shielded room. The EUT was connected to AC power source through an Artificial Mains Network (LISN) which provide a 50Ω linear impedance Artificial hand is used if appropriate (for handheld apparatus). The ac mains terminal disturbance voltage was measured with passive voltage probe if LISN wan not appropriate. The table-top EUT was placed on a 0.4m high non-metallic table above earthed ground plane(ground Reference Plane).And for floor standing EUT, was placed on a 0.1m high nonmetallic supported on GRP. The EUT keeps a distance of at least 0.8m from any other of the metallic surface. The Artificial Mains Network is situated at a distance of 0.8m from the EUT. During the test, mains lead of EUT excess 0.8m was folded back and forth parallel to the lead so as to form a horizontal bundle with a length between 0.3m and 0.4m. The bandwidth of test receiver was set at 9kHz. The frequency range from 150kHz to 30MHz was checked. Page 7 of 28

9 4.1.4 Test Data At main terminal: Pass Model No: SOFAR 40000TL-S0 Tested Wire: Live 1 Operation Mode: DC input 720V/AC output 277V(Worst case) Frequency Quasi-Peak Average [MHz] Disturbance Permitted Disturbance Permitted level limit level limit [db(µv)] [db(µv)] [db(µv)] [db(µv)] < < < < < < < < < < < < < < < < Tested Wire: Live 2 Operation Mode: DC input 720V/AC output 277V(Worst case) Frequency Quasi-Peak Average [MHz] Disturbance Permitted Disturbance Permitted level limit level limit [db(µv)] [db(µv)] [db(µv)] [db(µv)] < < < < < < < < < < < < < < < < Page 8 of 28

10 Tested Wire: Live 3 Operation Mode: DC input 720V/AC output 277V(Worst case) Frequency Quasi-Peak Average [MHz] Disturbance Permitted Disturbance Permitted level limit level limit [db(µv)] [db(µv)] [db(µv)] [db(µv)] < < < < < < < < < < < < < < < < Page 9 of 28

11 Model No: SOFAR 33000TL-S0 Tested Wire: Live 1 DC input 600V/AC output 230V (Worst case) Report No.: GZU-001 Frequency Quasi-Peak Average [MHz] Disturbance Permitted Disturbance Permitted level limit level limit [db(µv)] [db(µv)] [db(µv)] [db(µv)] < < < < < < < < < < < < < < < < Tested Wire: Live 2 DC input 600V/AC output 230V (Worst case) Page 10 of 28

12 Frequency Quasi-Peak Average [MHz] Disturbance Permitted Disturbance Permitted level limit level limit [db(µv)] [db(µv)] [db(µv)] [db(µv)] < < < < < < < < < < < < < < < < Tested Wire: Live 3 DC input 600V/AC output 230V (Worst case) Frequency Quasi-Peak Average [MHz] Disturbance Permitted Disturbance Permitted level limit level limit [db(µv)] [db(µv)] [db(µv)] [db(µv)] < < < < < < < < < < < < < < < < Tested Wire: Neutral DC input 600V/AC output 230V (Worst case) Page 11 of 28

13 Frequency Quasi-Peak Average [MHz] Disturbance Permitted Disturbance Permitted level limit level limit [db(µv)] [db(µv)] [db(µv)] [db(µv)] < < < < < < < < < < < < < < < < Measurement Uncertainty The measurement uncertainty describes the overall uncertainty of the given measured value during the operation of the EUT. Measurement uncertainty is calculated in accordance with CISPR : Measurement uncertainty of mains terminal disturbance voltage in CISPR band B: 2.58 db. The measurement uncertainty is given with a confidence of 95%, k= Emission Telecommunications/network port Test Result: Not Applicable Remark: The test only apply to balanced telecommunication ports intended for connection to unscreened balanced pairs 4.3 Emission Low voltage AC mains port (Clicks) Test Result: Not Applicable Page 12 of 28

14 4.4 Emission- Enclosure port (30 MHz 1000 MHz) Test Result: Pass Used Test Equipment Equip. No. Equipment Model Manufacturer A m Semi-Anechoic Chamber (m) A EMI Test Receiver ESCI R&S A Super Broadband test Antenna VULB09160 R&S Block Diagram of Test Setup ETSLINDGREN Antenn a mask EUT Turn Table Page 13 of 28 Receiver

15 4.4.3 Test Setup and Procedure The measurement was applied in a semi-anechoic chamber. The EUT and simulators were placed on a 0.8m high wooden turntable above the horizontal metal ground plane. The turn table rotated 360 degrees to determine the position of the maximum emission level. The EUT was set 10 meters away from the receiving antenna which was mounted on an antenna mask. The antenna moved up and down between from 1meter to 4 meters to find out the maximum emission level. Broadband antenna was used as receiving antenna. Both horizontal and vertical polarization of the antenna was set on measurement. In order to find the maximum emission, all of the interface cables were manipulated during radiated test. The bandwidth setting on R&S Test Receiver was 120 khz. The frequency range from 30MHz to 1000MHz was checked Test Curve & Test Data Model No: SOFAR 40000TL-S0 Operation Mode: DC input 720V/AC output 277V(Worst case) Antenna Polarization Frequency [MHz] Measured Net at 10m [db(µv/m)] Limit at 10m [db(µv/m)] Horizontal < Horizontal < Horizontal < Vertical < Vertical < Vertical < Model No: SOFAR 33000TL-S0 Operation Mode: DC input 600V/AC output 230V (Worst case) Page 14 of 28

16 Antenna Polarization Frequency [MHz] Measured Net at 10m [db(µv/m)] Report No.: GZU-001 Limit at 10m [db(µv/m)] Horizontal < Horizontal < Horizontal < Vertical < Vertical < Vertical < Measurement uncertainty The measurement uncertainty describes the overall uncertainty of the given measured value during the operation of the EUT. Measurement uncertainty is calculated in accordance with CISPR :2003. Measurement uncertainty of radiated emission: 4.87 db. The measurement uncertainty is given with a confidence of 95%, k= Emission Enclosure port (1 GHz 6 GHz) Test Result: Not Applicable Remark: The highest internal source of the EUT is not more than 108 MHz, so the measurement above 1000 MHz is not applicable. Page 15 of 28

17 5 Appendix I - Photos of test setup Emission Low voltage AC mains port (Conducted emission) Emission Enclosure port (30 MHz 1000 MHz) Page 16 of 28

18 6 Appendix II- Photos of EUT Photos: Overall view of the unit for model SOFAR 40000TL-Sx and SOFAR 33000TL-Sx Bottom view of the unit model SOFAR 40000TL-Sx and SOFAR 33000TL-Sx Page 17 of 28

19 Terminals view of the unit model SOFAR 40000TL-Sx and SOFAR 33000TL-Sx Internal view model SOFAR 40000TL-Sx and SOFAR 33000TL-Sx Page 18 of 28

20 Internal view of the unit model SOFAR 40000TL-Sx and SOFAR 33000TL-Sx Internal view of the unit model SOFAR 40000TL-Sx and SOFAR 33000TL-Sx Page 19 of 28

21 Control board PCB soldering view Page 20 of 28

22 Output board PCB soldering view Page 21 of 28

23 Combiner board PCB soldering view Page 22 of 28

24 Power board PCB soldering view Page 23 of 28

25 AC EMI board PCB soldering view Page 24 of 28

26 Input board PCB soldering Page 25 of 28

27 Communication board PCB soldering view Page 26 of 28

28 LCD display board PCB soldering view Page 27 of 28

29 Driver board Bottom of driver board (End of the report) Page 28 of 28

TEST REPORT... 1 CONTENT...

TEST REPORT... 1 CONTENT... CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMF RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 5 4 EMI TEST... 6 4.1 DISTURBANCE VOLTAGE ON MAINS TERMINALS ( KHZ- MHZ)...

More information

TEST REPORT... 1 CONTENT...

TEST REPORT... 1 CONTENT... CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2

More information

TEST REPORT. : Masterbuilt Manufacturing Inc. 1 Masterbuilt Court Columbus, Georgia, 31907, USA

TEST REPORT. : Masterbuilt Manufacturing Inc. 1 Masterbuilt Court Columbus, Georgia, 31907, USA Applicant Name & Address Sample Description Product TEST REPORT Report No.: 170527172GZU-001 : Masterbuilt Manufacturing Inc. 1 Masterbuilt Court Columbus, Georgia, 31907, USA : 30 inch Electric Smoker

More information

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen To: TEST REPORT No.: (5216)033-0357(A) PARTICLE INDUSTRIES, INC TEST REPORT To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: - 94107 Fax: -- Fax: - E-mail: -- E-mail:

More information

FCC Verification TEST REPORT

FCC Verification TEST REPORT FCC Verification TEST REPORT Product: 5 in 1 Environment Meter Model no.: ET-965 Trade Mark: N/A Report No.: TCT140915E005 Issued Date: Sep. 22, 2014 Issued for: Shenzhen Flus Technology Co., Ltd 3rd Floor,

More information

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC VERIFICATION SUMMARY Report No.: SZHH EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA

More information

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen To: TEST REPORT No.: (5216)033-0360(A) PARTICLE INDUSTRIES, INC TEST REPORT To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: - 94107 Fax: -- Fax: - E-mail: -- E-mail:

More information

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS... 4 2. GENERAL INFORMATION... 5 2.1 Details of E.U.T.... 5 2.2 Description of Support Device... 5 2.3 Block Diagram of Test Setup... 5 2.4 Test Facility...

More information

FCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: -

FCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: - FCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: - 94107 Fax: -- Fax: - E-mail: -- E-mail: - Folder No.: BVCZ16FE005ETHS-B

More information

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement... TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS... 4 2. GENERAL INFORMATION... 5 2.1 Details of E.U.T.... 5 2.2 Description of Support Device... 5 2.3 Block Diagram of Test Setup... 5 2.4 Test Facility...

More information

Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd.

Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd. Page 1 of 13 Report No. R011603851E Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd. Digital Scale Model No.: SH-370, SH-368, SH-366, SH-367, SH-369, SH-233, SH-228, SH-258, SH-235,

More information

STC Test Report. The Hong Kong Standards and Testing Centre Ltd.

STC Test Report. The Hong Kong Standards and Testing Centre Ltd. Date: 2011-11-15 Page 2 of 15 CONTENT: Cover Page 1 of 15 Content Page 2 of 15 1.0 General Details 1.1 Equipment Under Test [EUT] Page 3 of 15 Description of sample(s) 1.2 Description of EUT operation

More information

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement... TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS... 4 2. GENERAL INFORMATION... 5 2.1 Details of E.U.T.... 5 2.2 Description of Support Device... 6 2.3 Block Diagram of Test Setup... 6 2.4 Test Facility...

More information

TEST REPORT. Issued for:

TEST REPORT. Issued for: TEST REPORT FCC ID: 2ACJAPLT76XXG Product: TABLET PC Model No.: PLT7650G, PLT7649G, PLT76XXG ( XX can be replaced by digital from 00 to 99 ) Trade mark: N/A Report No.: TCT150721E012 Issued Date: Aug.

More information

FCC TEST REPORT On Behalf of. Global Tech China Limited. Solar Light(Large)/28W,16W. Model No.: Additional Model No: Please Refer To Page 15

FCC TEST REPORT On Behalf of. Global Tech China Limited. Solar Light(Large)/28W,16W. Model No.: Additional Model No: Please Refer To Page 15 FCC TEST REPORT On Behalf of Global Tech China Limited Solar Light(Large)/28W,16W Model No.: 00013022 Additional Model No: Please Refer To Page 15 Prepared for : Global Tech China Limited Address : 3 Flat

More information

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019 Page 1 of 22 Report No. 201311760E EMC TEST REPORT for Repel-it REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019 Applicant : Repel-it Address 168 Logan Road, Woolloongabba, Brisbane,

More information

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT For NanJing JingZe Lighting Technology Co.,Ltd No. 30, Hengfa Rd., National Economic Technological Development Zone, Nanjing, Jiangsu, China Tested Model:

More information

King Pigeon Communication Co., Limited

King Pigeon Communication Co., Limited APPLICATION FOR ELECTROMAGNETIC COMPATIBILITY DIRECTIVE On Behalf of King Pigeon Communication Co., Limited Remote Controller RTU Model No.: S130, S140, S150, S180, S25x, S26x, S27x, RTU501x, RTU502x,

More information

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight EMC Bayswater Pty Ltd 52 Holloway Drive Bayswater, Victoria, 3153, Australia Telephone: +61 3 9762 4111 Facsimile: +61 3 9762 8519 Email: sales@emcbayswater.com.au ABN: 49 112 221 333 EMC COMPLIANCE REPORT

More information

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U Prepared for Address : GZTOD.CO., LTD : 2-5/F, Building A4, Huimingsheng Industrial Park, Tongfuyu

More information

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION...3 2. GENERAL INFORMATION...4 2.1 Equipment under Test (EUT) Description...4 2.2 Test Standards and Results...5 2.3 Facilities and Accreditations...6 2.3.1

More information

MEASUREMENT REPORT FCC Part 15B

MEASUREMENT REPORT FCC Part 15B MRT Technology (Suzhou) Co., Ltd Phone: +86-512-66308358 Report V0sion: V03 Fax: +86-512-66308368 Issue Date: 02-05-2016 Web: www.mrt-cert.com MEASUREMENT REPORT FCC Part 15B FCC ID: APPLICANT: YZZGXP2160

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China Report

More information

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203

More information

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax: EMC TEST REPORT Report No.: Product: Model No. : FCC2012-8029E GSM Tracker PRIME AT PLT Brand Name: PRIME Applicant: Address: Issued by: Lab Location: RADISYS CORPORATION 601 North Congress Ave Suite 439,

More information

BUREAU VERITAS. itaste svd

BUREAU VERITAS. itaste svd BUREAU VERITAS TEST REPORT No.: (5213)095-0238 TEST REPORT To: INNOKIN TECHNOLOGY CO., LTD I Fax: I -- Attn: -- I -- I Address: Buildinq 6, XinXinTian Industrial Park, XinSha Road, Sha.Jinq street, ShenZhen,

More information

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8 Page 1 of 19 APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 Prepared for : Carewell Electric Technology (Zhongshan) Co., Ltd.

More information

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE

More information

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd Page 1 of 27 FCC Test Report Report No.: AGC01039170608FE08 FCC ID : PODTYT-X1U TYPE OF AUTHORIZATION : Certification APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Analog Transceiver BRAND

More information

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR Prepared for Address : SHENZHEN EAGLE TECHNOLOGY CO., LTD : A FIoor 1 BIdg.14, Changfeng

More information

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera VCCI TEST REPORT According to Class B ITE Equipment : USB video camera Model No. : V-U0011 Applicant : Logitech Far East Ltd. 2 Creation Road IV, Science-Based Ind. Park, Hsinchu, Taiwan. The test result

More information

APPLICATION FOR VERIFICATION On behalf of MATRIX LIGHTING LTD. LED spot light. Model No.: 50-45GUS 50-45EUS Serial No.: E /02 E /02

APPLICATION FOR VERIFICATION On behalf of MATRIX LIGHTING LTD. LED spot light. Model No.: 50-45GUS 50-45EUS Serial No.: E /02 E /02 Page : 1 of 26 APPLICATION FOR VERIFICATION On behalf of MATRIX LIGHTING LTD. LED spot light Model No.: 50-45GUS 50-45EUS Serial No.: E1103090-01/02 E1103090-02/02 Prepared For : MATRIX LIGHTING LTD. ROOM

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25 15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4 Revision History Version Issue Date Revisions Content Rev. 01 Jul. 25, 2018 Initial Issue Rev. 02 Sep. 05, 2018 Added the USB test mode in section 4.4 Test Configurations and data in ANNEX A TEST RESULTS.

More information

EMI T E S T R E P O R T

EMI T E S T R E P O R T EMI T E S T R E P O R T - FCC Part 15B - Test Report No. : T38935-00-02TK 27. November 2014 Date of issue Type / Model Name : One Touch Select Plus Flex Product Description : Blood glucose meter with Bluetooth

More information

RF test report AU01+W02

RF test report AU01+W02 Customer: Kehlbergstrasse 109 8054 Graz Austria Tel.: +43 664 415 6260 RF test report 170186-AU01+W02 The test result refers exclusively to the tested model. This test report may not be copied or published

More information

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 4 Revision History Version Issue Date Revisions Content Rev. 01 May 19, 2017 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION... 4 1.1 Identification of the Testing Laboratory... 4 1.2 Identification

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27 15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE

More information

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21 Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test Results 5.1 Summary of Test Results 5.2 Conducted Emissions Measurement

More information

FCC PART 15 B MEASUREMENT AND TEST REPORT

FCC PART 15 B MEASUREMENT AND TEST REPORT FCC PART 15 B MEASUREMENT AND TEST REPORT For FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, 47100 PUCHONG, SELANGOR, MALAYSIA MODEL: i-kadex August 11, 2009 This Report Concerns:

More information

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT Nemko-CCL, Inc. 1940 West Alexander Street Salt Lake City, UT 84119 801-972-6146 Test Report Declaration of Conformity Test Of: MICRO-RM2.4-LB Test Specification: FCC PART 15, Subpart B ICES-003, Issue

More information

Guangdong Alpha Animation and Culture Co.,Ltd. MERCEDES-BENZ SLS AMG. Model: LC ( ) Superregenerative Receiver. Report No.

Guangdong Alpha Animation and Culture Co.,Ltd. MERCEDES-BENZ SLS AMG. Model: LC ( ) Superregenerative Receiver. Report No. Guangdong Alpha Animation and Culture Co.,Ltd. Application For Certification MERCEDES-BENZ SLS AMG Model: LC258810-8 (6000814) Superregenerative Receiver We hereby certify that the sample of the above

More information

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above. FCC REPORT Applicant: Address of Applicant: Manufacturer/Factory: Address of Manufacturer/Factory: Guangzhou Smamao Electronic Technology Co.,Ltd Room 811, Building 8, No.315, Central City, Middle Road,

More information

STC Test Report. Date: Page 2 of 25 No.: MH The Hong Kong Standards and Testing Centre Ltd.

STC Test Report. Date: Page 2 of 25 No.: MH The Hong Kong Standards and Testing Centre Ltd. Date: 2013-05-22 Page 2 of 25 CONTENT: Cover Page 1 of 25 Content Page 2 of 25 1.0 General Details 1.1 Equipment Under Test [EUT] Page 3 of 25 Description of sample(s) 1.2 Description of EUT operation

More information

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated Page 1 of 17 FCC 15.209 & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report for A Acer Incorporated 8F., No.88, Sec. 1, Xintai 5th Rd., Xizhi, New Taipei City 22181, Taiwan (R.O.C) Product

More information

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

More information

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021 VCCI TEST REPORT According to V-3/2009.04, TECHNICAL REQUIREMENTS, Class B ITE Equipment : USB video camera Model No. : V-U0017 / V-U0021 Applicant : Logitech Far East Ltd. 2 Creation Road IV, Science-Based

More information

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co. TEST REPORT Applicant Address Shenzhen Innokin Technology Co., Ltd Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China Manufacturer or Supplier Address Product

More information

TEST REPORT Title 47-Telecommunication

TEST REPORT Title 47-Telecommunication TEST REPORT Title 47-Telecommunication Chapter I - Federal Communications Commission Subchapter A - General Part 5 - Radio Frequency Devices Subpart B - Unintentional Radiators Report Reference No....

More information

FCC 47 CFR PART 15 SUBPART B

FCC 47 CFR PART 15 SUBPART B FCC 47 CFR PART 15 SUBPART B TEST REPORT For DC TO DC CONVERTER Model : D100 Series Issued for MicroPower Direct, LLC 232 Tosca Drive Stoughton, MA02072 U.S.A. Issued by Compliance Certification Services

More information

FCC ID: B4OCC264BPA-S

FCC ID: B4OCC264BPA-S FCC TEST REPORT FCC ID: B4OCC264BPA-S Product : Bluetooth LE Module Model Name : CC264BPA-S, CC265BPA-S, CC26xBPA Brand : GT-tronics Report No. : PTC801181160622E-FC01 Prepared for GT-tronics HK Ltd Unit

More information

FCC 47 CFR PART 15 SUBPART B TEST REPORT KST DIGITAL TECHNOLOGY LIMITED. Brushless Servo

FCC 47 CFR PART 15 SUBPART B TEST REPORT KST DIGITAL TECHNOLOGY LIMITED. Brushless Servo FCC 47 CFR PART 15 SUBPART B TEST REPORT KST DIGITAL TECHNOLOGY LIMITED Brushless Servo Model No.: X20-3612 Additional Model No.: X20-1035, X20-2208, X20-3012, X20-9650, BLS159, BLS651, BLS259, BLS359,

More information

FCC PART 15 B MEASUREMENT AND TEST REPORT

FCC PART 15 B MEASUREMENT AND TEST REPORT FCC PART 15 B MEASUREMENT AND TEST REPORT For FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, 47100 PUCHONG, SELANGOR, MALAYSIA MODEL: Keylock 8800 April 12, 2010 This Report Concerns:

More information

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax: No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : +86-755-27912080 Fax: +86-755-27916936 FCC TEST REPORT Product name : 7PORT DUAL SUPPLY POE SWITCH

More information

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS Page 1 of 49 TESTT REPORT For Applicant : ACOUSTMAX INTERNATIONAL CO.., LTD Unit D16/F Cheuk Nang Plaza 250 Hennessy Road Address : WanchaiHongKong Product Name : Monster GLO Model Name : MNGLO-S, MNGLO-L,MNGLO-M,MNGLO-Mini

More information

D. Guarnone (verifier)

D. Guarnone (verifier) TEST REPORT Title 47-Telecommunication Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart B - Unintentional Radiators Report Reference No....354297-4TRFFCC

More information

FCC TEST REPORT. For Datastore Technology Corp. T35278

FCC TEST REPORT. For Datastore Technology Corp. T35278 FCC TEST REPORT For Datastore Technology Corp. T35278 Model No. : T3527 VIII Prepared for : Datastore Technology Corp. 9F, No. 10, Sec. 1, Chung Hsing Rd., Wu-Ku District, New Taipei City, Taiwan, R.O.C.

More information

FCC CLASS B COMPLIANCE REPORT (DoC)

FCC CLASS B COMPLIANCE REPORT (DoC) FCC CLASS B COMPLIANCE REPORT (DoC) for Electromagnetic Emissions Of ENTRY LEVEL IP PHONE Trade Name : XONTEL Model Number : XT-19P Serial Number : N/A Report Number : PZD1611741-F Date : Regulations :

More information

Content. Report No. SH Page 2 of 22

Content. Report No. SH Page 2 of 22 Page 2 of 22 Content SUMMARY...1 1. GENERAL INFORMATION...3 1.1 Description of Equipment Under Test (EUT)...3 1.2 Description of Client...3 1.3 Description of Test Facility...3 2. TEST SPECIFICATIONS...4

More information

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B. Test Standards: FCC Part 15B Measurement and Test Report Product Description: Tested Model: Report No.: For GlobTek, Inc. 186 Veterans Dr. Northvale, NJ 07647 USA FCC Part 15 Subpart B Power Supply GT-93020-0324

More information

FCC PART 15B TEST REPORT SZ DJI TECHNOLOGY CO., LTD

FCC PART 15B TEST REPORT SZ DJI TECHNOLOGY CO., LTD FCC PART 15B TEST REPORT For SZ DJI TECHNOLOGY CO., LTD 14th floor, West Wing, Skyworth Semiconductor Design Building NO.18 Gaoxin South 4th Ave, Nanshan, Shenzhen, Guangdong, China FCC ID: SS3-G1S1612

More information

3. MEASURING DEVICES AND TEST EQUIPMENT For Radiated Emission Measurement... 6

3. MEASURING DEVICES AND TEST EQUIPMENT For Radiated Emission Measurement... 6 TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS... 3 2. GENERAL INFORMATION... 4 2.1 Details of E.U.T.... 4 2.2 Description of Support Device... 4 2.3 Block Diagram of Test Setup... 5 2.4 Test Facility...

More information

FCC Test Report FCC ID: XN6-SB3651E6

FCC Test Report FCC ID: XN6-SB3651E6 FCC Test Report FCC ID: XN6-SB3651E6 Product: Trade Mark: Model Number: Serial Model: Report No.: 36 Inch Sound Bar 5.1 System VIZIO SB3651-E6 N/A NTEK- 2017NT02221568F Prepared for Zylux Acoustic Corporation

More information

FCC PART TEST REPORT. Weccan Industrial Limited

FCC PART TEST REPORT. Weccan Industrial Limited FCC PART 15.249 TEST REPORT For Weccan Industrial Limited Rm209, 2/F, Building W1-A, No.34 Gaoxin South 4th St Hi-Tech Industrial Park, Nanshan District, Shenzhen China FCC ID: Z3CWECCANDRONE Report Type:

More information

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS201708000040F02 FCC REPORT Applicant: Address of Applicant: Manufacturer: Dongguan Hele Electronics Co.,Ltd. Dalingya Industrial Zone,Daojiao Town,Dongguan City,Guangdong,China Dongguan

More information

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.: 10050333 001 Seite 2 von 19 Page 2 of 19 TEST SUMMARY 5.1 CONDUCTED EMISSION PER SECTION 15.107, FCC 47 CFR PART 15 SUBPART B RESULT: Pass 5.2 RADIATED EMISSION PER SECTION 15.109, FCC 47 CFR PART 15 SUBPART

More information

To «Test_Standards» Test of: Radwin Ltd. Outdoor Subscriber Radio Unit. To: FCC CFR 47 Part 15B; ICES-003 Issue 6: 2016

To «Test_Standards» Test of: Radwin Ltd. Outdoor Subscriber Radio Unit. To: FCC CFR 47 Part 15B; ICES-003 Issue 6: 2016 TEST REPORT ADDENDUM Part 15B & ICES-003 FROM To «Test_Standards» Test of: FCC CFR 47 Part 15B; ICES-003 Issue 6: 2016 Test Report Serial No.: Issue 13 th July 2016 Master Document Number RDWN41 U5 _Master

More information

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above. + Applicant: Address of Applicant: Manufacturer: FCC REPORT Dongguan Hele Electronics Co.,Ltd. Report No.: GTS201708000040F01 Dalingya Industrial Zone,Daojiao Town,Dongguan City,Guangdong,China Dongguan

More information

Verification of Conformity On Behalf of

Verification of Conformity On Behalf of Verification of Conformity On Behalf of EVERPRO TECHNOLOGIES COMPANY LTD. HDMI Active optical Cable Model No.: HDMI OPTICAL FIBER CABLE 330FT, 300FT, 250FT, 200FT, 150FT, 100FT, 50FT Prepared for : EVERPRO

More information

Sunlight Supply, Inc.

Sunlight Supply, Inc. FCC Part 18 Subpart C Non-Consumer For RF Lighting Equipment Electromagnetic Compatibility Test Report Sunlight Supply, Inc. Commercial Ballast 1000 Watt - July 18, 2017 Tests Conducted by:, LLC 20811

More information

STC Test Report. Date : Page 1 of 13 No. : HM161169

STC Test Report. Date : Page 1 of 13 No. : HM161169 Date : 2009-05-11 Page 1 of 13 Applicant (ATS001): Atech Scientific Measurement Limited. Room A-C, 18 Floor, Luk Hop Ind. Bldg, 8 Luk Hop Street, Kowloon Manufacturer: Atech Scientific Measurement Limited.

More information

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15. Page 1 of 51 Report No.: T1851663 01 TEST REPORT FCC ID: 2AGJ5WAP-30 Applicant Address : Gonsin Conference Equipment Co., Ltd : No.401-406,Block C, Idea Industry Park, No.41 Fengxiang Road, Shunde, Foshan,

More information

FCC PART MEASUREMENT AND TEST REPORT

FCC PART MEASUREMENT AND TEST REPORT FCC PART 15.109 MEASUREMENT AND TEST REPORT FOR ThinNetworks IT products Limited SAAN 02 #260- Industrial Zone Brasilia- DF, Brazil- 70.632-200 FCC ID: WQ3CF-000585 Report Concerns: Original Report Equipment

More information

FCC Test Report. Report No.: PTCDQ FC01

FCC Test Report. Report No.: PTCDQ FC01 Page 1 of 63 FCC Test Report Report No.: PTCDQ04170450501-FC01 FCC ID : 2AL2XW801 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : WIFI DoorBell BRAND NAME : EASTIC MODEL NAME : W801, W802,

More information

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI 53012 262-375-4400 COMPLIANCE TESTING OF: Quartex Synchronization Transmitter Model FM-72 PREPARED FOR: Quartex, Division of Primex, Inc. 965

More information

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No. Page 1 of 20 FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER Equipment Under Test [EUT]: Model Number: Applicant: FCC ID : Radio Controlled Tank FH002 Zhongshan Fu Hai Electronics

More information

1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES... TABLE OF CONTENTS 1 - GENERAL INFORMATION... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 1.2 TEST STANDARDS... 3 1.3 TEST SUMMARY... 3 1.4 TEST METHODOLOGY... 4 1.5 TEST FACILITY... 4

More information

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2 www.nemko.com Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2 Report Number: Product Marketing Name: 123766-1TRFEMC Paycheck 4 Thermal Ticket Printer Test Specification: FCC

More information

EMI Test Report. : BTv4.0 Dual Mode USB Dongle

EMI Test Report. : BTv4.0 Dual Mode USB Dongle EMI Test Report Equipment Model No. Brand Name Applicant Address Standard : BTv4.0 Dual Mode USB Dongle : BT820 : Laird Technologies : Laird Technologies Received Date : Jan. 23, 2017 W66N220 Commerce

More information

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm) Page 41 of 103 9.6. Test Result The test was performed with 802.11b Channel Frequency (MHz) power ANT 1(dBm) power ANT 2 (dbm) power ANT 1(mW) power ANT 2 (mw) Limits dbm / W Low 2412 7.20 7.37 5.248 5.458

More information

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of Activision Publishing, Inc USB Wireless Receiver for Wii & USB Wireless Receiver for PS3 Trade Name : Activision. Model Number: 83973791/84148791

More information

Description of Test Facility

Description of Test Facility Description of Test Facility Name: Address: Intertek Testing Services Limited Shanghai Building No.86, 1198 Qinzhou Road(North), Shanghai 200233, P.R. China FCC Registration Number: 236597 IC Assigned

More information

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18 CONTENT TEST REPORT...1 CONTENT...2 1 TEST RESULTS SUMMARY...4 2 EMC RESULTS CONCLUSION...5 3 LABORATORY MEASUREMENTS...6 4 EMI TEST...7 4.1 EN 55014-1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST...7

More information

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS1308-1809-W2E Customer Customer's representative In the capacity of Reference number

More information

FINGERTEC WORLDWIDE SDN BHD FCC REPORT FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, PUCHONG, SELANGOR, MALAYSIA

FINGERTEC WORLDWIDE SDN BHD FCC REPORT FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, PUCHONG, SELANGOR, MALAYSIA FINGERTEC WORLDWIDE SDN BHD FCC REPORT Prepared For : FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, 47100 PUCHONG, SELANGOR, MALAYSIA Product Name: Trade Name: Fingerprint T&A

More information

C E R T I F I C A T I O N

C E R T I F I C A T I O N C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.

More information

FCC Test Report. FCC Part 15 Subpart B. Neets A/S. Touch Panel (Touch Panel-7B) 2AM ZKS E. William Liu (Engineer)

FCC Test Report. FCC Part 15 Subpart B. Neets A/S. Touch Panel (Touch Panel-7B) 2AM ZKS E. William Liu (Engineer) FCC Test Report FCC Rule(s): Applicant: Product Name: Model: FCC ID: Report No.: FCC Part 15 Subpart B Neets A/S Touch Panel 313-0001(Touch Panel-7B) 2AM35-313-0001 ZKS170600143E Tested Date: 2017-07-06

More information

TEST REPORT. Report No. : AJ Date : 2007 November 01

TEST REPORT. Report No. : AJ Date : 2007 November 01 Application No. : LJ220521(1) Applicant : JADA TOYS CO., LTD. UNIT 901, 9/F., ENERGY PLAZA, 92 GRANVILLE ROAD, T.S.T. EAST, KLN., HONG KONG. Sample Description : One(1) submitted sample(s) stated to be

More information

T A B L E O F C O N T E N T S DESCRIPTION PAGE

T A B L E O F C O N T E N T S DESCRIPTION PAGE TABLE OF CONTENTS DESCRIPTION PAGE 1. CERTIFICATION... 3 2. SUMMARY OF TEST RESULTS... 4 3. GENERAL INFORMATION... 5 3.1 PRODUCTION DESCRIPTION... 5 3.2 TEST MODES & EUT COMPONENTS DESCRIPTION... 5 3.3

More information

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758 Page 1 of 20 Report No. R011604553E EMC TEST REPORT for DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., LTD. Electronic calculator Model No.: KF15758 Prepared for Address Prepared by Address : DONGGUAN EVER

More information

MEASUREMENT REPORT FCC Part 15B

MEASUREMENT REPORT FCC Part 15B MRT Technology (Suzhou) Co., Ltd Phone: +86-512-66308358 Report Version: V01 Fax: +86-512-66308368 Issue Date: 06-30-2016 Web: www.mrt-cert.com MEASUREMENT REPORT FCC Part 15B FCC ID: APPLICANT: 2AC23-WC0DR2611

More information

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT For Rock Industries USA INC 105-10 Northern Blvd. Corona. NY 11368 FCC ID: QXE 268A9 April 9, 2003 This Report Concerns: Original Report Equipment

More information

FCC Test Report. Report No.: AGC FE03. MODEL NAME : Ci3, Ti3, CB3, AO, UI, Vinyl I, Vinyl B, M2

FCC Test Report. Report No.: AGC FE03. MODEL NAME : Ci3, Ti3, CB3, AO, UI, Vinyl I, Vinyl B, M2 Page 1 of 51 FCC Test Report FCC ID : VO8CI3 APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Bluetooth headset BRAND NAME : Bluedio MODEL NAME : Ci3, Ti3, CB3, AO, UI, Vinyl I, Vinyl B,

More information

FCC REPORT. Lightcomm Technology Co., Ltd.

FCC REPORT. Lightcomm Technology Co., Ltd. FCC REPORT Report No.: GTS201608000267E01 Applicant: Lightcomm Technology Co., Ltd. Address of Applicant: RM 1808 18/F FO TAN INDUSTRIAL CENTRE NOS. 26-28 AU PUI WAN STREET FO TAN SHATIN NEW TERRITORIES

More information

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FCC TEST REPORT APPLICANT : GN Netcom Inc PRODUCT NAME : Bluetooth Headsets MODEL NAME : HSC040W TRADE NAME : N/A BRAND NAME : Jabra FCC ID : BCE-HSC040W STANDARD(S) : 47 CFR Part 15 Subpart B TEST DATE

More information

Jul. 16, Jun. 04, Shenzhen. Tel:(86-755)

Jul. 16, Jun. 04, Shenzhen.   Tel:(86-755) Test Report FCC ID.: MTi160413E004 Date of issue: Jul. 16, 2016 Sample Description: Wireless POS Terminal Model(s): G3 Applicant: Shenzhen Xinguodu Technology Co., Ltd. Address: 17/A, Jinsong Building

More information

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release REVISION HISTORY The revision history for this document is shown in table. Version Issue Date Description HCT-EM-1801-FC037 January 22, 2018 Initial Release HCT-EM-1801-FC037-R1 January 26, 2018 Revision

More information

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT For Tritech Technology Ltd. Unit B, 8/F, Chung Pont Commercial Building No. 300 Hennessy Road, WanChai, Hong Kong. Model: 209517 Report Type: Original

More information

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz

More information

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply C-Tick EMC TEST REPORT For AC/DC Switching Power Supply Model: CP0515(5V/1.5A); CP0520(5V/2A); CP0530 (5V/3A); CP0540 (5V/4A); CP0550 (5V/5A); CP0560 (5V/6A);CP0615(6V/1.5A); CP0620(6V/2A); CP0625 (6V/2.5A);

More information