REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Size: px
Start display at page:

Download "REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045"

Transcription

1 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Project No. G FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE Date: June 6, 2013 REPORT NO CRT-001 TEST OF ONE LED FLOOD LIGHT FIXTURE MODEL NO. PF10014GWUWHD DRIVER MODEL NO. LEDINTA0700C210DO LED MODEL NO. ILLUMITEX AV446S-503GW RENDERED TO ILLUMITEX, INC INDUSTRIAL OAKS BLVD SUITE 100 AUSTIN, TX TEST: Electrical and Photometric tests as required to the IESNA test standard. LABORATORY NOTE: The laboratory that conducted the testing detailed in this report has been Qualified, Verified, and Recognized for LM-79 Testing for ENERGY STAR for SSL by US DOE's CALiPER program. STATEMENT OF LIMITATION: This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. AUTHORIZATION: The testing performed was authorized by signed quote number STANDARDS USED: IESNA LM-79: 2008 The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: Approved Method for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI ANSLG C38.377: 2012 Specifications of the Chromaticity of Solid State Lighting Products Energy Star Version 1.1 (2008): Program Requirements for Solid-State Lighting Luminaires Energy Star Manufacturer s Guide Version 2.0 (2009): Guide for Qualifying Solid State Lighting Luminaires DESCRIPTION OF SAMPLE: The client submitted one production sample of model number PF10014GWUWHD. The sample was received by Intertek on May 24, 2013, in undamaged condition, and one sample was tested as received. The sample designation was CRT DATES OF TESTS: June 4, 2013 through June 6, This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

2 SUMMARY Model No.: Description: PF10014GWUWHD LED FLOOD LIGHT Result Criteria Sphere Goniometer Total Lumen Output (Lumens) Total Power (W) Luminaire Efficacy (LPW) Criteria Result Power Factor (at 120 Vac) Power Factor (at 277 Vac) Current ATHD (% at 120 Vac) 5.30 Current ATHD (% at 277 Vac) 9.48 Correlated Color Temperature (CCT - K) 5875 Color Rendering Index (CRI) Ra 72.8 Color Rendering Index (CRI) - R9-4.7 Duv Chromaticity Coordinate (x) Chromaticity Coordinate (y) Chromaticity Coordinate (u ) Chromaticity Coordinate (v ) Maximum In-Situ Source Temperature Point ( C) 50.9 EQUIPMENT LIST Control Number Last Calibration Date Calibration Due Date Equipment Used Model Number Leeds & Northup Standard Resistor Manganin Y089 02/07/13 02/07/14 Data Precision Digital Voltmeter 3600 V124 02/07/13 02/07/14 Fluke Multimeter 45 M133 02/07/13 02/07/14 Kikusui DC Power Supply 35-10L E Sorenson DC Power Supply DLM150-20E NIST Spectral Flux Standard Source RF /18/ hours of use LSI High Speed Mirror Goniometer /20/13 06/20/13 Elgar Power Supply CW VBU VBU Yokogawa Power Analyzer WT210 E464 04/17/13 04/17/14 Extech Hygro Thermometer T /08/12 11/08/13 Fisher Scientific --- N /22/13 04/22/14 M-D Building Products Smart Tool L112 02/13/13 02/13/14 Yokogawa Power Analyzer WT1600 E462 07/06/12 07/06/13 LABSPHERE 3M W/ CDS 1100 N307 VBU VBU Fluke Temperature Meter 53 II T /15/13 03/15/14 Extech Hygro-Thermometer T /08/12 11/08/13 Fluke Multimeter PM2525 M127 10/17/12 10/17/13 Fluke Temperature Meter 53 II D588 03/15/13 03/15/14 Report No CRT-001 page 2 of 9 Date: June 6, 2013

3 TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical measurements Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. In-Situ Maximum Measured Power Supply Case and LED Source Point Temperature Power supply case and/or LED source operating temperature measurements were taken on one test sample per model with a thermocouple and Fluke 87 temperature meter. The SSL sample was allowed to reach thermal equilibrium for seven and a half hours before measurements were taken. Power supply or source temperature measurements were measured at the TMP PS or T S point as indicated by the included diagram in accordance with manufacturers declared hot spot location, or at a hot spot location found with a thermal camera when no diagram from the manufacturer is given. The maximum temperature was recorded for the sample. A simulated ceiling or other enclosure may be used in accordance to UL 1598 or UL 153 as applicable. Report No CRT-001 page 3 of 9 Date: June 6, 2013

4 RESULTS OF TESTS Spectral Distribution over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm Sample No. CRT Spectral Data Over Visible Wavelengths (mw/nm) Nanometers Report No CRT-001 page 4 of 9 Date: June 6, 2013

5 RESULTS OF TESTS (cont d) Photometric and Electrical Measurements at 25 C Integrating Sphere Method Intertek Sample No. CRT Base Voltage Current Power Absolute Luminous Flux Lumen Efficacy (Lumens Orientation (Vac) (ma) (Watts) (Lumens) Per Watt) UP Correlated Color Temperature Intertek Sample No. (K) CRT Intertek Sample No. CRT CRI -Ra CRI -R9 DUV CIE 31 Chromaticity Coordinate (x) CIE 31 Chromaticity Coordinate (y) Power Factor 120 Vac Current ATHD (%) 120 Vac Power Factor 277 Vac CIE 76 Chromaticity Coordinate (u ) Current ATHD (%) 277 Vac 9.48 CIE 76 Chromaticity Coordinate (v ) Photometric and Electrical Measurements Distribution Method Intertek Sample No. CRT Base Orientation UP Voltage (Vac) Current (ma) Power (Watts) Power Factor Absolute Lumen Luminous Efficacy Flux (Lumens (Lumens) Per Watt) Intensity (Candlepower) Summary at 25 C - Candelas Angle Report No CRT-001 page 5 of 9 Date: June 6, 2013

6 RESULTS OF TESTS (cont d) Illumination Plots Illuminance - Cone of Light Mounting Height: 10 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zone Lumens % Luminaire Zonal Lumens and Percentages at 25 C Zone Report No CRT-001 Lumens % Luminaire page 6 of 9 Date: June 6, 2013

7 RESULTS OF TESTS (cont d) In-Situ Maximum Measured LED Source Temperature Manufacturer Supplied Documentation: LED identified as: ILLUMITEX AV446S-503GW Report No CRT-001 page 7 of 9 Date: June 6, 2013

8 RESULTS OF TESTS (cont d) In-Situ Maximum Measured LED Source Temperature Maximum Junction Temperature from LED specification (Tj) = 125 C Thermal Resistance Formula from LED specification = 2 C/W Maximum Forward Voltage (Vf) from LED specification = 13.4 V Measured LED Current = 687 ma Calculated LED Wattage = Vf x Measured LED Current = W Maximum Source Temperature (Ts) = Tj (LED Wattage x Thermal Resistance) =107 C Maximum Measured Manufacturer Designated Source Temperature Sample No. Maximum Measured Source Temperature ( C) Location Maximum Rated Source Temperature( C) CRT Per diagram 107 In-Situ Pictures Ts Report No CRT-001 page 8 of 9 Date: June 6, 2013

9 Picture (not to scale) CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determinedd in this report. In Charge Of Tests: Report Reviewed By: Vladimir Kozak Associate Engineer Lighting Division David Ellis Senior Project Engineer Lighting Division Attachment: None Report No CRT-001 page 9 of 9 Date: June 6, 2013

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 Project No. G101555841 Date: March 21, 2014 REPORT NO. 101555841CRT-001 TEST OF ONE LED

More information

www.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-010 TEST OF PAR 38 LED LAMPS MODEL NOS. S8854 / S8861

More information

www.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-018 TEST OF PAR 30L LED LAMPS MODEL NOS. S8814 / S8821

More information

www.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-039 TEST OF LED CANDLE LAMPS MODEL NOS. S8899 / S8903

More information

www.greenelectricalsupply.com REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100125842 Date: August 17, 2010 REPORT NO. 100125842CRT-036 TEST OF LED CANDLE LAMPS MODEL NOS. S8891 / S8894

More information

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003 TEST REPORT Job No. 170101691SHA Date: February 19, 2017 REPORT NO. 170101691SHA-003 TEST OF Outdoor Full-Cutoff Wall-mounted Area Luminaires MODEL NO. WP-ADS30U-40B / WP-ADS30U-40B-PC RENDERED TO Maxlite,

More information

Test Report. Report Number: L16023 Date: Apr 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16023 Date: Apr 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1623 Date: Apr 6, 216 Issued by: 151 Route 3 South, Farmingdale, NJ 7727 Test of one 2ft End-to-End Linear With Clear Lens Unit manufacturer: Dialight Corporation Unit model

More information

Test Report. Report Number: L16022 Date: Apr 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16022 Date: Apr 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1622 Date: Apr 6, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one 2ft End-to-End Linear With Diffused Lens Unit manufacturer: Dialight Corporation Unit model

More information

Test Report. Report Number: L16082 Date: Nov 1, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16082 Date: Nov 1, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1682 Date: Nov 1, 216 Issued by: 151 Route 3 South, Farmingdale, NJ 7727 Test of one Die Cast Floodlight Unit manufacturer: Dialight Corporation Unit model number: FLx22xCNP

More information

Test Report. Report Number: L16009 Date: Feb 12, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16009 Date: Feb 12, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L169 Date: Feb 12, 216 Issued by: 151 Route 4 South, Farmingdale, NJ 7727 Test of one Vigilant 18K With Glass Lens Unit manufacturer: Dialight Corporation Unit model number:

More information

Test Report. Report Number: L15131 Date: Oct 16, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15131 Date: Oct 16, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1511 Date: Oct 16, 215 Issued by: 151 Route 4 South, Farmingdale, NJ 7727 Test of one Vigilant Highbay With Glass Lens Unit manufacturer: Dialight Corporation Unit model number:

More information

Test Report. Report Number: L15100 Date: Jul 8, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15100 Date: Jul 8, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L151 Date: Jul 8, 215 Issued by: 151 Route 4 South, Farmingdale, NJ 7727 Test of one 26k Vigilant Highbay With Glass Lens Unit manufacturer: Dialight Corporation Unit model number:

More information

Test Report. Report Number: L15085 Date: Jul 1, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15085 Date: Jul 1, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L1585 Date: Jul 1, 215 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one Vigilant Highbay With Ultra Clear Polycarbonate Lens Unit manufacturer: Dialight Corporation

More information

Test Report. Report Number: L16050 Date: Jun 1, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L16050 Date: Jun 1, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L165 Date: Jun 1, 216 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one Vigilant Highbay Unit manufacturer: Dialight Corporation Unit model number: HEA9MC4PN-BCG

More information

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO. TEST REPORT Job No. 170400516SHA Date: Apr 12,2017 REPORT NO. 170400516SHA-006 TEST OF ONE LED Luminaire MODEL NO. RENDERED TO Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. TEST:

More information

Test Report. Report Number: L15163 Date: Jan 13, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15163 Date: Jan 13, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L15163 Date: Jan 13, 2016 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one LED Floodlight Unit manufacturer: Dialight Corporation Unit model number: FLx276xC2NG

More information

Test Report. Report Number: L15160 Date: Jan 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15160 Date: Jan 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L15160 Date: Jan 6, 2016 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one DuroSite 4500 Unit manufacturer: Dialight Corporation Unit model number: STW4C2N Issued

More information

Test Report. Report Number: L14070 Date: Oct 9, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L14070 Date: Oct 9, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L14070 Date: Oct 9, 2014 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant 60K High Bay Unit manufacturer: Dialight Corporation Unit model number: H6UGNC44NXXXX

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L051603301 Date: 5/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051603301 Report Prepared For: Colt LED Model Number: D12X6-GEN3-55W

More information

Test Report. Report Number: L15033 Date: Mar 24, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15033 Date: Mar 24, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L15033 Date: Mar 24, 2015 Issued by: 1501 Route 34 South, Farmingdale, NJ 07727 Test of one Vigilant Highbay With Clear Acrylic Lens Unit manufacturer: Dialight Corporation Unit

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L041609601 Date: 5/5/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041609601 Report Prepared For: GM LIGHTING 9830 W 190th St,

More information

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063 Report No: L121500506 Date: 12/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500506 Report Prepared For: Revolution Lighting Technologies

More information

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02 Report No: L041608503 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608503 Report Prepared For: GM LIGHTING 9830 W 190th St,

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L071600301 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600301 Report Prepared For: Revolution Lighting Technologies

More information

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02 Report No: L071600303 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600303 Report Prepared For: Revolution Lighting Technologies

More information

Equipment Used Model No Stock No Calibration Due Date

Equipment Used Model No Stock No Calibration Due Date Report No: L091401801 Date: 9/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091401801 Report Prepared For: Olympia Lighting, inc. 50

More information

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI

Beachside Lighting 905 Kalanianaole Hwy # 29A Kailua, HI Report No: L061606106 Date: 7/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061606106 Report Prepared For: Beachside Lighting 905 Kalanianaole

More information

BARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649

BARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649 Report No: L101601204 Date: 10/18/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L101601204 Report Prepared For: BARTCO Lighting 5761 Research

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L061507801 Date: 7/20/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L061507801 Report Prepared For: Beachside Lighting 905 Kalanianaole

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L121404501R02 Date: 12/22/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121404501R02 Report Prepared For: Texas Fluorescents

More information

Number Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000

Number Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000 Report No: L121706545 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706545 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,

More information

Client submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.

Client submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary. Report No: L031500702 Date: 3/13/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031500702 Report Prepared For: EiKO Global, LLC 23220 W.

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L051503011 Date: 5/21/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051503011 Report Prepared For: USTE, dba Vista Professional

More information

Calibration Due Date Chroma Programmable AC Source 61604

Calibration Due Date Chroma Programmable AC Source 61604 Test #: L04130402 Date: 5/2/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L04130402 TVL4000 CW Report Prepared For: ELATION

More information

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063 Report No: L091706904 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091706904 Issue Date: 10/9/2017 Report Prepared For: USTE, dba Vista Professional Outdoor Lighting 1625 Surveyor

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L091502201 Date: 9/10/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091502201 Report Prepared For: Vista Professional Outdoor

More information

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard Lamp specifics: Luminaire Used: none none Rated Watts Voltage: 6.75 Watts Lamp Type: LPL-W18-120C-930 / 78875 / Rated Orientation CCT: VBD Test Requester E.Z. Cola Rated Voltage 12 V DC New Product: 1

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L10131601 Date: 10/10/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L10131601 ELED Strip TW BOTH A Report Prepared

More information

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79. Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503505 Report Prepared For: Revolution Lighting Technologies

More information

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79. Report No: L111503504 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503504 Report Prepared For: Revolution Lighting Technologies

More information

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063 Report No: L091706906 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091706906 Issue Date: 10/9/2017 Report Prepared For: USTE, dba Vista Professional Outdoor Lighting 1625 Surveyor

More information

Vista Professional Outdoor Lighting 1625 Surveyor Ave., Simi Valley CA Fixture is tested with no special conditions.

Vista Professional Outdoor Lighting 1625 Surveyor Ave., Simi Valley CA Fixture is tested with no special conditions. Report No: L021606506 Date: 3/4/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L021606506 Report Prepared For: Vista Professional Outdoor

More information

1120 Goffle Road Hawthorne NJ Photometric/Colorimetric/Electrical Test

1120 Goffle Road Hawthorne NJ Photometric/Colorimetric/Electrical Test Report No: L111708109 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L111708109 Issue Date: 1/10/2018 Report Prepared For: CAST Lighting LLC. 1120 Goffle Road Hawthorne NJ 07506-2024

More information

Revolution Lighting 4139 Guardian St. Simi Valley CA 93063

Revolution Lighting 4139 Guardian St. Simi Valley CA 93063 Report No: L121605937R02 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121605937R02 Issue Date: 2/17/2017 Report Prepared For: Revolution Lighting 4139 Guardian St. Simi Valley

More information

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506 Report No: L111407206 Date: 12/11/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407206 Report Prepared For: Cast Lighting 1120-A Goffle

More information

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions.

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions. Report No: L111407109 Date: 12/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407109 Report Prepared For: Cast Lighting 1120-A Goffle

More information

Moon Visions Lighting 780 S. Floyd Rd., Suite 2B, Richardson, TX Electrical and Photometric tests as required by the IESNA test standards.

Moon Visions Lighting 780 S. Floyd Rd., Suite 2B, Richardson, TX Electrical and Photometric tests as required by the IESNA test standards. Test #: L061402510 Date: 6/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L061402510 LED MV120V R30 14W 5K FL Report Prepared

More information

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., 07506 Report No: L111407302 Date: 1/15/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407302 Report Prepared For: Cast Lighting 1120-A Goffle

More information

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions.

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ., Fixture is tested with no special conditions. Report No: L111407108 Date: 12/9/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111407108 Report Prepared For: Cast Lighting 1120-A Goffle

More information

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ 07506

Cast Lighting 1120-A Goffle Rd., Hawthorne, NJ 07506 Report No: L071407704 Date: 8/6/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071407704 Report Prepared For: Cast Lighting 1120-A Goffle

More information

EiKO Global, LLC W. 84th Street, Shawnee, KS 66227

EiKO Global, LLC W. 84th Street, Shawnee, KS 66227 Report No: L011508802 Date: 2/19/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L011508802 Report Prepared For: EiKO Global, LLC 23220 W.

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ. Test #: L08124408 Date:08/31/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L08124408 RR61430W Report Prepared For: MAXLITE

More information

U.S.T.E. dba Vista Professional Outdoor Lighting 1625 Surveyor Ave. Simi Valley CA Fixture is tested with no special conditions.

U.S.T.E. dba Vista Professional Outdoor Lighting 1625 Surveyor Ave. Simi Valley CA Fixture is tested with no special conditions. Report No: L081407404 Date: 9/3/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L081407404 Report Prepared For: U.S.T.E. dba Vista Professional

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L113141 Date: 1/8/213 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L113141 Model Number: LR22-33L-35K Report Prepared For: Raffino Inc. Test:

More information

752 North State St, #208, Westerville, OH Photosynthetically active radiation (PAR) & Electrical measurement

752 North State St, #208, Westerville, OH Photosynthetically active radiation (PAR) & Electrical measurement Report No: L091800301 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091800301 Issue Date: 9/10/2018 Report Prepared For: Horticulture Lighting Group 752 North State St, #208,

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI. Report No: L061606303 Date: 8/1/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061606303 Beachside Lighting

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L12125907R02 Date: 1/14/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12125907R02 LR24-5000L-35K Report Prepared

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE Jersey Blvd. Rancho Cucamonga, CA 91730 Test #: L06122603 Date: 6/15/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L06122603 MLRT24D5535 Report Prepared For: MAXLITE

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L1212321 Date: 12/1/212 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: L1212321 Model Number: LT24-4L-35K Report Prepared For: Raffino Inc.

More information

MANUFACTURE NAME 8165 E. KAISER BLVD, ANAHEIM, CA Electrical and Photometric tests as required by the IESNA test standards.

MANUFACTURE NAME 8165 E. KAISER BLVD, ANAHEIM, CA Electrical and Photometric tests as required by the IESNA test standards. Test #: ROADWAY Date: S01130101 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: S01130101 LUMINAIRE CATALOG NUMBER Report Prepared

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22 UL1598-28 Prepared For Simkar Corporation Andre Duljas 7 Ramona Ave Philadelphia, PA 1912 United States Catalog Number RG2LEDWR1741U1

More information

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806

More information

LM-79 Test Report. GE Infusion M1000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. GE Infusion M1000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard specifics: Luminaire Used: SRTGLEDGI SRTGLEDGI 15W 30K WD E1 GES66 15W 30KRated Voltage: Watts 15 watt Driver Type: Roal Strato GE RSLD035-7A Infusion M1000/83 Rated CCT: Orientation VBU GE Infusion M1000/830/W/N

More information

LM-79 Test Report. GE Infusion M2000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. GE Infusion M2000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard specifics: Luminaire Used: SGE4SQLEDGI SGE4SQLEDGI 30W 30K ND E1 AR0204LGI 30W 3SG Rated FGCC Voltage: Watts 30 watt Driver Type: Roal Strato GE RSLD035-07 Infusion M2000/83 Rated CCT: Orientation VBU

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Myles Standish Blvd.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Myles Standish Blvd. Report No: L051604201 Date: 6/1/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L051604201 Lexington Lighting

More information

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Kalanianaole Hwy # 29A Kailua, HI. Report No: L061507817R01 Date: 8/10/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061507817R01 Beachside

More information

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 WALLPACK Model: MLSWP30LED50DS Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L113411R1 Date: 1/28/213 8165 E Kaiser Blvd. Anaheim, CA 9288 p. 714.282.227 f. 714.676.5558 NVLAP LAB CODE 2927 Test Report: Model Number: L113411R1 LR24-4L-5K-D-S Report Prepared For: Raffino

More information

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014 IESNA LM-79: 2008 Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE Dec 08, 2014 Product Name: LED Model No: 82031 Test Engineer: David Zhang Report No.: BTR66.181.14.0039.06

More information

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA. IESNA LM-79: 2008 Measurement and Test Report for Jiawei Technology (USA) Limited 2305 Lincoln Ave.Hayward, CA 94545 USA Apr 03, 2015 Product Name: self-ballast LED Lamp Model No: DL-9PAR30-830-LN-25-D;ML-9PAR30-830-LN-25-D

More information

No seasoning was performed in accordance with IESNA LM-79.

No seasoning was performed in accordance with IESNA LM-79. Test #: L01134102R01 Date: 1/28/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L01134102R01 LR24-5000L-50K-D-S Report Prepared

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED PAR30 Spot light Model: 524142XX(XX:41-50) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 01-10) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 61-70) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540741XX(XX: 01-10) Laboratory:

More information

ELATION LIGHTING 6122 S. EASTERN AVE, COMMERCE, CA Electrical and Photometric tests as required by the IESNA test standards.

ELATION LIGHTING 6122 S. EASTERN AVE, COMMERCE, CA Electrical and Photometric tests as required by the IESNA test standards. Test #: L09133804 Date: 10/9/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L09133804 ELED Strip TW CW Report Prepared For:

More information

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 LM-79-08 Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 Model(s): Spectrum Lighting SG12SQLED21W35KE1/12SQGW/3.5LA 8 May 2011 This test report presents the results of measurements

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22, UL 1598-28 UL1598-28 Prepared For AVID Labs Alexander Tollington 4121 Fourier Drive Fort Wayne, IN 46818 United States Product Name:

More information

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR IESNA LM-79: 2008 Measurement and Test Report for EiKO Global, LLC Sep 09, 2013 Product Name: LED Model No: LED8WMR16/38/830-DIM Test Engineer: David Zhang Report No.: BTR66.181.13.1294.01-1 Sample Received

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320 Report No: L061605303 Date: 6/16/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061605303 HK Lighting Group

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Old Conejo Road #118, Newbury Park, CA, 91320 Report No: L061605301 Date: 6/16/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L061605301 HK Lighting Group

More information

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50 LM-79-08 Test Report for Maxlite Inc. 12 York Ave West Caldwell NJ 07006 LED Canopy Model: MLCAN20LED50 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com

More information

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd. IESNA LM-79: 2008 Measurement and Test Report for 14 Inverness Drive East,Ste.E-128 Englewood, CO 80112 Jun 15, 2011 Product Name: T8 Tube Model No: T8L1200-18W-02-120-32 Test Engineer: David Zhang Report

More information

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model: LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Catalog Number IGTTU-2102550G-4T5

More information

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary Test Summary Sample Tested: ML4LS10SOLBK Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 55.2 552.2 10.01 0.9797 CCT Stabilization Time CRI (K) (Light & Power)

More information

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A LM-79-08 Test Report for Elec-Tech International Co., Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China BR40 LAMP Model: 525021XX(XX:01-10), WBR40L27S2A Laboratory:

More information

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR Quality Assured NVLAP LAB CODE 200960-0 L 1-79-08 Test Report for EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR Laboratory: Leading Testing Laboratories

More information

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Laboratory: Leading Testing Laboratories

More information

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson

More information

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Ref. No.: Version: 1.0 IESNA SUSTAINING MEMBER LCZP17060295 Date of issue: Jun. 29, 2017 Total pages: 12 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State

More information

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products IESNA SUSTAINING MEMBER Date of issue Mar 17, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Rendered

More information

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG IESNA LM-79: 2008 Measurement and Test Report for Green Creative Ltd. Room 1206-7, New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Sep 02,2013 Product Name: LED PAR30 Model No: 14PAR30G3DIM/827FL40

More information

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03176 PAGE: 1 OF 9 LUMINAIRE: CAST WHITE PAINTED FINNED METAL HEAT SINK,SHEETMETAL JUNCTION BOX AFFIXED TO TOP OF HEATSINK, 1 CIRCUIT BOARD WITH 10 LEDS. LAMPS: TEN WHITE MULTI-CHIP LIGHT

More information