Photometric Test Report
|
|
- Evelyn Chandler
- 5 years ago
- Views:
Transcription
1 Photometric Test Report Relevant Standards IES LM ANSI C UL / UL Prepared For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Catalog Number IGTTU G-4T5 Project Number Report Number Test Date 10/10/ /13/2016 Issue Date Prepared By Approved By Duff Yang Jonathan Xu The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. UL Report Number Page 1 of
2 1.0 Test Summary DLC Technical Requirements v4.0 Zonal Lumen Requirement 2 Minimum Luminaire Efficacy (lm/w) Minimum Lamp Efficacy (lm/w) Alowable CCTs* (K) Minimum CRI L70 Lumen maintenance (hours) L90 Lumen maintenance (hours) Power Factor Total Harmonic Distortion (A%) In-Situ Temperature Measurement Test for LED In-Situ Temperature Measurement Test for Driver Minimum Luminaire Warranty (years) Test Method Requirements Test value Results (Fail/Pass) IES LM In Fixture: 4500 lm 5516 Pass IES LM Bare Lamp: 1600 lm Pass IES LM Pass IES LM Pass IES LM % 85% Pass IES LM N/A N/A N/A IES LM Pass IES LM Pass IES LM Pass IES LM CIE Pass IES LM IES TM Pass IES LM IES TM N/A N/A N/A ANSI C Pass ANSI C % 10.70% Pass UL / UL UL / UL Pass N/A N/A N/A N/A 5 5 Pass *Defined by ANSI C ǂ ǂANSI C also referred to for Duv and (x,y) chromaticity coordinates tolerances for indoor categories. Requirement Category Minimum Light Output (lm) Minimum Lamp Output (lm) Spacing Criteria (0-180 ) Spacing Criteria ( ) Zonal Lumen Requirement (0-60 ) Type C, Four-foot Linear Replacement Lamps UL Report Number Page 2 of
3 3.0 Test List Test Item Test Test Date Model Number Tests Conducted By 1 Integrating Sphere Test for the Lower CCT IGTTU G-4T5 Blaire Xiong 2 Integrating Sphere Test for the Higher CCT IGTTU G-4T5 Blaire Xiong 3 Goniophotometer Test IGTTU G-4T5 Blaire Xiong 4 THD and PF Test IGTTU G-4T5 Blaire Xiong 5 In-Situ Temperature Measurement Test 10/13/2016 IGTTU G-4T5 Blaire Xiong Remark (if any) 1. UL test equipment information is recorded on Meter Use in UL s Laboratory Project Management (LPM) database. 2. The lamps were tested with an instant start ballast# U-254T5HO-1 which ballast factor is UL Report Number Page 3 of
4 4.0 Production Description Luminaire Description: V, 64 W Lighting Source: IGT LIGHTING INC. Mounting: T5 linear replacement lamps, Type A, 4 ft Family Model: IGTTU G-4T5 Variation: Only Variation in CCT. Photos of Luminaire Characteristics Bare Lamp Ballast UL Report Number Page 4 of
5 5.0 LM-79 Measurement and Test Results 5.1 Integrating Sphere Test for the lower CCT Model No. IGTTU G-4T5 Sample ID , Opreate time (Min.) 50 Stabilization time (Min.) Test Method 1. The sample was tested according to the IES LM Photometric paramters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. 3. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at rated voltage and was stabilized before measurement. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at 1 nm intervals over the range of 380 to 780 nm. Integrating Sphere Test Conditions Temperature Voltage (Vac) Frequency(Hz) Current (A) Power (W) Power (W)/ 2 Power Factor Test Results Orientation CCT (K) CRI (Ra) Duv Luminous Flux Luminous Efficacy (lm) (lm/ W) Horizontal UL Report Number Page 5 of LM-79 Measurement and Test Results
6 5.2 Integrating Sphere Test for the higher CCT Model No. IGTTU G-4T5 Sample ID , Opreate time (Min.) 50 Stabilization time (Min.) Test Method The sample was tested according to the IES LM Photometric paramters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. 3. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at rated voltage and was stabilized before measurement. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at 1 nm intervals over the range of 380 to 780 nm. Temperature Integrating Sphere Test Conditions Voltage (Vac) Frequency(Hz) Current (A) Power (W) Power (W)/ 2 Power Factor Test Results Orientation CCT (K) CRI (Ra) Duv Luminous Flux (lm) Horizontal Luminous Efficacy (lm/ W) UL Report Number Page 6 of
7 5.0 LM-79 Measurement and Test Results 5.3 Goniophotometer Test Model No. IGTTU G-4T5 Sample ID , Opreate time (Min.) 50 Stabilization time (Min.) 45 Test Method 1. The sample was tested according to the IES LM in fixture Lithonia 2GT A12 MVOLT 1/4 GEB10IS. 2. Photometric paramters were measured using a type C goniophotometer and software. 3. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. 4. The samples were operated at rated voltage and was stabilized before measurement. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 0.5 o vertical intervals and 22.5 o horizontal intervals. Temperature Goniophotometer Test Conditions Voltage (Vac) Frequency Current (A) Power (W) Power Factor Orientation Horizontal Flux (lm) (50%) Horizontal Spread Vertical Spread % Center Candela (cd) 2193 Zonal Lumen Requirement (0-60 ) Spacing Criteria (0-180 ) Test Result Field Angle (10%) Horizontal Vertical Spread Spread Spacing Criteria ( ) Beam Angle Luminous Efficacy (lm/ W) Issue:3.0 UL Report Number Page 7 of
8 5.2 Goniophotometer Test (Cont'd) Light Distribution Curve IsoCandela Plot UL Report Number Page 8 of 14 2
9 5.2 Goniophotometer Test (Cont'd) Zonal Lumen Summary Lumens Per Zone UL Report Number Page 9 of 14 3
10 5.2 Goniophotometer Test (Cont'd) Intensity Data(cd) UL Report Number Page 10 of 14
11 6.0 THD and PF Test Model No. IGTTU G-4T5 Sample ID , Test Method 1. The samples were tested according to the ANSI C The ambient temperature condition was maintained at 25º C ± 1º C. The sample measurement was made using a digital power meter and power supply. The sample was operated at rated voltage and stabilized before measurement. The total harmonic distortion were calculated from thedigital power meter. Temperature Test Results Voltage (Vac) Frequency Current (A) Power (W) Power Factor Current THD % UL Report Number Page 11 of
12 7.0 In-Situ Temperature Measurement Test Model No. IGTTU G-4T5 Sample ID , Test Method 1. In-Situ Temperature Measurement Test is conducted according to the UL , Section 14 or UL , Section 8.5 in fixture Lithonia 2GT A12 MVOLT 1/4 GEB10IS. 2. The testing was conducted in a room with ambient temperature of 25 C ± 5 C. The apparatus construction followed those described in UL for normal temperature testing. Thermocpuples were placed on the LED package in the locations indicated by LM-80 report. The temperature was recorded after the lamp was operated by 3.5 hours in stability or by 7.5 hours. Temperature In-Situ Temperature Measurement Test Conditions Voltage (Vac) Frequency Current (A) Power (W) Power Factor Orientation Horizontal Thermocouple Location Manufacturer Declared Current (ma) Test Results Temperature for Lighting source Test result column 1 Test result (Correct to 25 C) LED Model Number LM-80 Limit Current (ma) LM-80 Limit Temp. TMP1 of LEDs TMP2 of LEDs TMP3 of LEDs S Series (3000K) Ambient temperature N/A UL Report Number Page 12 of 14
13 7.0 In-Situ Temperature Measurement Test (Cont'd) Test Photos for Tc Point of LED Packages T3 T2 T1 UL Report Number Page 13 of
14 ****** END OF REPORT. THIS PAGE INTENTIONALLY LEFT BLANK ****** UL Report Number Page 14 of 14 1
Photometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 Prepared For MaxLite Inc 0 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x46, rraghavan@maxlite.com Test Laboratory & Address:
More informationAddress: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K
Customer Company & Address: Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Contact Person: Mohit K Mittal Phone Number: +91 9811204494 Email Address: mohit@overdriveasia.com Relevant
More informationPhotometric Test Report
Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com
More informationPhotometric Test Report
Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com
More informationREVOLUTION LIGHTING TECHNOLOGIES INC
LM-79-08 Test Report For REVOLUTION LIGHTING TECHNOLOGIES INC (Brand Name: Revolution Lighting Technologies) 2280 Ward Ave, Simi Valley, CA 93065 Integrated Retrofit Kits for 2x4 Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires
LM-79-08 Test Report For Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): Remark: The suffix X can be A, B, B2, C, C2, D, D2, E, E2, F, F2 representing different mounting bracket; Y
More informationNVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ
LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA High-bay Luminaires for Commercial and Industrial Buildings Model name(s): FI-HB-2FT-110W
More informationNVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA ) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Full-Cutoff Wall-mounted Area Luminaire Model
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FI-CPL1212*603-50W-D
More informationNVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)
More informationNVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013
LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 High-bay Luminaires for Commercial and Industrial Buildings Model name(s): LED-9300-XXK Remark:
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 LED High Bay Light Model name(s): 502288##
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 Wall Pack Model name(s): 533041xx Representative
More informationNVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730
LM-79-08 Test Report For ATG ELECTRONICS CORP (Brand Name: N/A) 10700 7th Street Rancho Cucamonga, CA 91730 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FPEL24-40W-ZZ
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson
More informationNVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires
LM-79-08 Test Report For LED Waves, Inc. 4100 1st. Ave. Brooklyn, NY 11232 USA Linear Retrofit Kits for 2x2 Luminaires Model name(s): LWQR2x2-40W Representative (Tested) Model: LWQR2x2-40W-4000K LWQR2x2-40W-5000K
More informationLM Test Report
LM-79-08 Test Report For IRICO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD Aotom LED Industrial Park, Qingzhuanhu Road 268, Huanggang, Hubei, China LED Panel Light Model name(s): 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH)
More informationNVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS
LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th St., Shawnee, KS 66227. Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): WPT1-55/8XX-BZ-U Remark:The letter X in the model name stands
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-30W Remark: X=CCT(4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Full-Cutoff Wall-mounted Area Luminaire Model name(s): HC-WPC-40 Representative
More informationLM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen High-bay Luminaires for Commercial and Industrial Buildings
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWP2-80W Remark:The letter X in the model name stands for CCT as bellow :3=3000K, 4=4000K, 5=5000K; YY stands for mounting
More information57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG
57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard
More informationLM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA
LM-79-08 Test Report For Revolution Lighting Technologies, Inc (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 113XS8-3LT Remark:
More informationNVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006
LM-79-08 Test Report For MAXLITE,INC (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006 Direct Linear Ambient Luminaires Representative (Tested) Model: LSECO-4NU2050 Model Different: N/A Test & Report
More informationNVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101
LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-70W-30, LED2-ARD-70WD-30
More informationNVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101
LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-100W-30, LED2-ARD-100WD-30
More informationNVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA
LM-79-08 Test Report For BEYOND LED TECHNOLOGY (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 USA HD FPB Series - High Definition Outdoor Corn Bulb Decorative Luminaires
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 LED Ceiling Light Model name(s): 544661##
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No. 1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China, 519085 LED Linear Ambient Light Model Name(s):
More informationNVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)
LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Low Bay Luminaires for Commercial and Industrial Buildings
More information71332 LED Dusk To Dawn (Area Light)
71332 LED Dusk To Dawn (Area Light) 48 QPL ID # PK6ZRDD6 dusk-to-dawn photocell LM-79-08 Test Report For Morris Products Inc. (Brand Name: Morris) 53 Carey Road Queensbury, NY 12804 Outdoor Wall-Mounted
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires
More informationLM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454
LM-79-08 Test Report For KEYSTONE TECHNOLOGIES LLC (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 1x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): KT-PLED40-14-830-VDIM
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Fuel Pump Canopy Luminaires Model name(s): TLCLB80XYYZZ
More informationEternal Shine Technology Co.,Ltd. EST
Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine
More informationLM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)
LM-79-08 Test Report For Torshare Ltd. (Brand Name: TORSHARE) 5th Minying Road No.3 Industrial Area Shuitian Shiyan Town Bao'an District,Shenzhen Guangdong 518108 China Direct Linear Ambient Luminaires
More informationDark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:
Catalog Number UPC Number Description 71452 60198671452 Dark Sky Wallpack 50W Features Full Cutoff Design to Prevent Up Light Integral Cooling Fins Release Heat Efficiently Corrosion Resistant Die Cast
More informationNVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006
LM-79-08 Test Report For Maxlite INC (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): MLFP24EP50XX Remark: The
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22 UL1598-28 Prepared For Simkar Corporation Andre Duljas 7 Ramona Ave Philadelphia, PA 1912 United States Catalog Number RG2LEDWR1741U1
More informationNVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)
LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Outdoor Pole/Arm-mounted Area and Roadway Luminaires
More informationCat# LED Wall-PACK
Cat# 71426 LED Wall-PACK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22, UL 1598-28 UL1598-28 Prepared For AVID Labs Alexander Tollington 4121 Fourier Drive Fort Wayne, IN 46818 United States Product Name:
More informationQPL ID # PLG2YNJ831VZ
Catalog Number 71732 UPC Number 60198671732 Description UFO High Bay 100W Features Integral Cooling Fins Release Heat Efficiently Corrosion Resistant Die Cast Aluminum Housing Polycarbonate Lens Superior
More informationLED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.
71352 LED Floodlight RoHS Model: 71352 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage
More informationNVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)
LM-79-08 Test Report For SHENZHEN BONLD ELECTRONICS CO.,LTD (Brand Name: BONLD) Bldg2-5, TongFuYu Industrial Park, Aiqun Road, Shiyan Town, Bao an District, Shenzhen, China 1x4 Luminaires for Ambient Lighting
More informationCat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69
Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI
More informationCat# 71440A LED Classic Large Wall-Pack
Cat# 71440A LED Classic Large Wall-Pack Dimming: 0-10V/PWM/VR QPL ID # PL8EA2B65DY8 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power
More informationDirect to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.
LED Wall-PACK/Flood Light Data Sheet Cat# 71152 Direct to wall RoHS Wet Locations Use QPL ID # PLUV5PQHJX3Z Model: 71152 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Input Voltage
More informationDimming: PWM/TIME/0-5V/0-10V. RoHS
Dimming: PWM/TIME/0-5V/0-10V Cat# 71575A 150 Watts Pole Mount RoHS QPL ID # PLMWEKHWJOBH Model: 71575A OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance
More informationRoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS
Cat# 71543 150 Watts Trunion Mount RoHS QPL ID # PF9T16AA Model: 71543 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam
More informationRoHS QPL ID # PLC6V1PABNUJS
Cat# 71836 220 Watts Trunion Mount RoHS QPL ID # PLC6V1PABNUJS OVERALL LAMP PARAMETERS LED DRIVER LED Input Power Power Factor Luminance Luminous Efficiency CRI R9 8 Beam Angle Main Structure Output Voltage
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number UPC Number Description 71466A 60198671466 LED Vandal Resistant Canopy Light 80W Voltage: 120/277 Features Corrosion Die Cast Aluminum Housing Prismatic Polycarbonate Lens Superior Architectural
More informationRoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.
Cat# 71896 380W FlatPanel Pole Mount Model: 71896 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure
More informationwww.greenelectricalsupply.com P 0 0 0 Cat# 71574A 100 Watts Pole Mount RoHS QPL ID # PLV5YTKQ0SQJ OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous
More informationRoHS. Model: VAC 50/60HZ.83A Max 100W
Cat# 71542 100 Watts Trunion Mount RoHS UL/CUL TUV-CE QPL ID # PTX2Q1C3 Model: 71542 Input Voltage Input Current Input Power 100-277VAC 50/60HZ.83A Max 100W OVERALL LAMP PARAMETERS LED DRIVER LED Power
More informationRoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90
Cat# 71554 30 Watts 1/2" Knuckle Mount RoHS QPL ID # PHNRJ3EY Model: 71554 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI
More informationPhotometric Test Report
UL LLC 1075 W Lambert Rd Suite B Brea, CA 92821 Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2017, IES TM-30-2015 UL LLC 1075 W Lambert
More informationCat# LED High Bay
Cat# 71402 LED High Bay QPL ID # PPXEAWS8 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: 71402 Input Voltage 100-277VAC 50/60HZ Input Current 1.2A Max Input Power 100 W
More information71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A
71345A 50W LED Floodlight Yoke(Bracket) Mount RoHS QPL ID # PLDUWHES4P5Q Model: Input Voltage Input Current Input Power Power Factor OVERALL LAMP Luminance PARAMETERS Luminous Efficiency CRI Beam Angle
More informationRoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.
Cat# 71544 220 Watts Trunion Mount Model: 71544 RoHS QPL ID # P9JSE2P8 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam
More informationRoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens
Cat# 71552 15 Watt 1/2" Adjustable Knuckle Mount RoHS QPL ID # P4K7RKA9 Model: 71552 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency
More informationCat# 71146A 150W Trunion Mount
Cat# 71146A 150W Trunion Mount RoHS Dimming: 0-10V/PWM/VR QPL ID # PLZOBKAFGDBR Model: 71146A Input Voltage 120-277 VAC 50/60HZ Input Current 1.7A MAX Input Power 150W Power Factor PF 0.90 OVERALL LAMP
More information71352A QPL ID # PLT2P2L2UNWR. RoHS
Dimming: 0-10V/PWM/VR 71352A 80W LED Floodlight Trunnion Mount Model: RoHS 71352A QPL ID # PLT2P2L2UNWR Input Voltage 100-277AC 50/60HZ Input Current 1.00A MAX Input Power 80 W Power Factor PF 0.90 OVERALL
More informationNVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)
LM-79-08 Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name: OKT LIGHTING) NO.2076 Jincheng Rd,Shajing Town, Bao'an District, Shenzhen, China. SSL downlight retrofits Model name(s): C10-D54W-XXE
More informationNVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)
LM-79-08 Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name: OKT LIGHTING) NO.2076 Jincheng Rd,Shajing Town, Bao'an District, Shenzhen, China. SSL downlight retrofits Model name(s): CE6-40W-XXE
More informationRoHS QPL ID # PNZ72BAB
Cat# 71541 80 Watts Trunion Mount RoHS QPL ID # PNZ72BAB OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure
More informationRoHS QPL ID # PNZ72BAB
Cat# 71561 80 Watts Slipfitter Mount Model: 71561 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure
More informationNVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG
LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED Lighting) Rm 1902, Easey Comm Bldg 253-261 Hennessy Rd Wanchai, HONG KONG LED Tube Light Model name(s): HC-T8-8FT-36W-ID(Clear) Representative
More informationwww.greenelectricalsupply.com Cat# 71855 220 Watts Pole Mount RoHS UL/CUL TUV-CE QPL ID # PLTP6C Q97 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008 Prepared For Lumificient Corp Deborah Jones 8752 Monticello Lane North Maple Grove, MN 55369-4549 Catalog Number EVG236-BB-AC-NW-UL1-XX
More informationNVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD
Energy Star Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name:OKT Lighting) NO.2076 Jincheng Rd, Shajing Town, Bao an District,Shenzhen, China SSL downlight retrofits Model name(s):c10-d40w-30e
More informationCat# LED Classic MINI Wall-PACK
Cat# 71418 LED Classic MINI Wall-PACK QPL ID # PL08MT480BZK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance
More informationLM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)
LM-79-08 Test Report For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Floor 3rd/4th/5th/6th Block6, Block21, Zhengdaan Industry Park No 172 Xiangshan Rd, Luotian Village Songgang Town, Baoan
More informationLM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U
Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03176 PAGE: 1 OF 9 LUMINAIRE: CAST WHITE PAINTED FINNED METAL HEAT SINK,SHEETMETAL JUNCTION BOX AFFIXED TO TOP OF HEATSINK, 1 CIRCUIT BOARD WITH 10 LEDS. LAMPS: TEN WHITE MULTI-CHIP LIGHT
More informationLM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:
LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB01842 PAGE: 1 OF 6 CATALOG NUMBER: SWISH2X2-29YN/D10 LUMINAIRE: WHITE PAINTED SHEET METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 60 LEDS, FROSTED POLYCARBONATE LENS IN THE CENTER,
More informationLM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50
LM-79-08 Test Report for Maxlite Inc. 12 York Ave West Caldwell NJ 07006 LED Canopy Model: MLCAN20LED50 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com
More informationTEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003
TEST REPORT Job No. 170101691SHA Date: February 19, 2017 REPORT NO. 170101691SHA-003 TEST OF Outdoor Full-Cutoff Wall-mounted Area Luminaires MODEL NO. WP-ADS30U-40B / WP-ADS30U-40B-PC RENDERED TO Maxlite,
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03145 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03414 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT
More informationChecked X.CAO
REPORT NUMBER: RAB02068 PAGE: 1 OF 7 CATALOG NUMBER: FXLED78SF - FXLED78T (SF=SLIPFITTER MOUNT & T=TRUNNION MOUNT) LUMINAIRE: CAST FINNED METAL HOUSING, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH AND
More informationReport No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light
More informationIESNA LM79: 2008 Photometric Test Report
IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Christian Groom Management Associate MaxLite Description of Sample: CPL Slim
More information1120 Goffle Road Hawthorne NJ Photometric/Colorimetric/Electrical Test
Report No: L111708109 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L111708109 Issue Date: 1/10/2018 Report Prepared For: CAST Lighting LLC. 1120 Goffle Road Hawthorne NJ 07506-2024
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light
More informationLM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB02177 PAGE: 1 OF 7 CATALOG NUMBER: SK21XL25RYY LUMINAIRE: STAMPED STEEL CEILING PAN WITH WHITE FINISH, 10 LED BOARDS EACH WITH 10 LEDS, ACRYLIC DROP LENS WITH SMOOTH FINISH. LAMPS: ONE-HUNDRED
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)
More information