Photometric Test Report
|
|
- Mariah Gordon
- 5 years ago
- Views:
Transcription
1 Photometric Test Report Relevant Standards IES LM ANSI C UL Prepared For Simkar Corporation Andre Duljas 7 Ramona Ave Philadelphia, PA 1912 United States Catalog Number RG2LEDWR1741U1 Order Number Test Number Test Date Prepared By Approved By Javier Caban, Technician Carissa Samonte-cam, Project Handler The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Test Number Page 1 of 8
2 Table of Contents Integrating Sphere Results Page 3 Page 4 Distribution Results Conditions / / Polar Plot / Zonal / Luminance Candela Tabulation Coefficients of Utilization Page 5 Page 5 Page 6 Page 7 In-Situ Results Page 8 Laboratory results may not be representative of field performance Ballast factors have not been applied Testing was performed in a 2-meter integrating sphere using the 4π geometry method. Absorption correction was employed for Sphere measurement Test Number Page 2 of 8
3 Luminaire Description: Lamp: Mounting: Ballast/Driver: White steel housing, white steel reflector plate, no enclosure 168 white LEDs, two boards with 84 LEDs each Pendant One Eaglerise ESL15-315P Luminaire Luminaire Characteristics Luminous Length: 23. in. Luminous Width: 18. in. Luminous Flux: Efficacy: CCT: CRI (Ra): Integrating Sphere 1771 Lumens 13.1 lm/w 4151 K 83.6 Distribution Total Luminaire Output: Luminaire Efficacy: Maximum Candela: 1719 Lumens 1.7 lm/w 5733 Candela Electrical Data at 277 VAC In-Situ Test Temperature: 25.2 C LED Temperature: 9.7 C Voltage: 277. VAC Driver Temperature: 61.2 C Current:.6541 A Maximum LED Current:.1498 A Power: Power Factor: W.931 Frequency: 6 Hz Temperature is offset to an ambient temperature of 25 C as Current THD: 17.2 % described in UL Test Number Page 3 of 8
4 Spectral Flux (mw/nm) Color Quality - Integrating Sphere Integrating Sphere Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 25.6 C 12. VAC A W Hz 5.2 % Total Output: Efficacy: CCT: CRI (Ra): CRI (R9): Chromaticity (x): Chromaticity (y): Chromaticity (u): Chromaticity (v): Chromaticity (u'): Chromaticity (v'): Duv: 1771 Lumens 13.1 lm/w 4151 K Insert Chromaticity Diagram Color Rendering Index Detail Ra (CRI) R1 R2 R3 R4 R5 R6 R7 R8 R9 R1 R11 R12 R13 R Flux vs Wavelength Wavelength (nm) Test Number Page 4 of 8
5 Distribution - Goniophotometer Distribution Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 25.1 C 12. VAC A 17.7 W Hz 4.94 % Spacing Criteria Total Lumen Output: -18: 1.28 Luminaire Efficacy: 9-27: 1.28 Maximum Candela: 1719 Lumens 1.7 lm/w 5733 Candela Polar Plot Deg. Plane 27 Deg. Plane Deg. Plane 9 Deg. Plane Zonal Lumen Summary Zone Lumens % of Luminaire Zone Lumens % of Luminaire Zone Lumens % of Luminaire % % % % % % % 6.5% % 1.2% % % % % 9.1% 9.1% 8.7% 8.% Zone Lumens % of Luminaire % 78.4% 1 Test Number Page 5 of 8
6 Vertical Angle (Degrees) Vertical Angle (Degrees) Candela Tabulation Horizontal Angle (Degrees) Average Luminance (cd/m 2 ) Horizontal Angle (Degrees) Test Number Page 6 of 8
7 Ceiling Cavity Reflectance Wall Reflectance Room Cavity Ratio (RCR) Utilization of Lumens - Zonal Cavity Method Effective Floor Cavity Reflectance 2% ** Values are expressed as Lumens delivered to the task surface ** Cone of Light Tabulation Mounting Footcandles Diameter Height (Feet) at Nadir (Feet) Cone of Light Plot Test Number Page 7 of 8
8 In-Situ Test In-Situ Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 23.3 C 12. VAC N/A N/A N/A 6 Hz N/A LED Temperature: Driver Temperature: Maximum LED Current: 9.7 C 61.2 C.1498 A Temperatures are offset to an ambient temperature of 25 C as described in UL LED Temperature Location Driver Temperature Location Test Number Page 8 of 8
Photometric Test Report
Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22, UL 1598-28 UL1598-28 Prepared For AVID Labs Alexander Tollington 4121 Fourier Drive Fort Wayne, IN 46818 United States Product Name:
More informationPhotometric Test Report
UL LLC 1075 W Lambert Rd Suite B Brea, CA 92821 Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2017, IES TM-30-2015 UL LLC 1075 W Lambert
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008 Prepared For Lumificient Corp Deborah Jones 8752 Monticello Lane North Maple Grove, MN 55369-4549 Catalog Number EVG236-BB-AC-NW-UL1-XX
More informationPhotometric Indoor Test Report
Photometric Indoor Test Report Relevant Standards LM-79-28 Prepared For Sea Gull Lighting Andre Duljas 31 W. Washington Street Riverside, NJ 875 Catalog Number 96118S-32 LTL Test Number 2191 Test Date
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2015, IES TM-30-2015 Prepared For Smart Grow Technologies 69319 Panoramic Dr Sisters,
More informationPOST TOP FIXTURE C40T
PROJECT TYPE VOLTAGE POST TOP FIXTURE C4T Wave Lighting s commercial product line provides safety and security for all types of applications including parks, pedestrian walkways, and parking areas. Our
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 Prepared For MaxLite Inc 0 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x46, rraghavan@maxlite.com Test Laboratory & Address:
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03414 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03145 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT
More informationHorticultural Lighting Test Report
UL LLC 1075 W Lambert Rd Suite B Brea, CA 92821 Horticultural Lighting Test Report Relevant Standards IES LM-79-2008, ANSI C82.77-2002, CIE 13.3-1995 CIE 15-2004, ANSI C78.377-2015, IES TM-30-2015 Prepared
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB03176 PAGE: 1 OF 9 LUMINAIRE: CAST WHITE PAINTED FINNED METAL HEAT SINK,SHEETMETAL JUNCTION BOX AFFIXED TO TOP OF HEATSINK, 1 CIRCUIT BOARD WITH 10 LEDS. LAMPS: TEN WHITE MULTI-CHIP LIGHT
More informationPhotometric Test Report
Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Catalog Number IGTTU-2102550G-4T5
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB01842 PAGE: 1 OF 6 CATALOG NUMBER: SWISH2X2-29YN/D10 LUMINAIRE: WHITE PAINTED SHEET METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 60 LEDS, FROSTED POLYCARBONATE LENS IN THE CENTER,
More informationHorticultural Lighting Test Report
Horticultural Lighting Test Report Relevant Standards IES LM-79-2008 ANSI C78.377-2011, ANSI C82.77-2002 CIE 13.3-1995, CIE 15-2004, IES TM-30-15 Prepared For Smart Grow Technologies 69319 Panoramic Dr
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB02177 PAGE: 1 OF 7 CATALOG NUMBER: SK21XL25RYY LUMINAIRE: STAMPED STEEL CEILING PAN WITH WHITE FINISH, 10 LED BOARDS EACH WITH 10 LEDS, ACRYLIC DROP LENS WITH SMOOTH FINISH. LAMPS: ONE-HUNDRED
More informationAcuVivid CV Series. sirs-e.com. Flexible White LED Strips
AcuVivid CV Series Flexible White LED Strips The SIRS-E AcuVivid CV White LED strip series consists of High Quality Constant Voltage variants with color temperatures, but not limited to, 27, 4 and 55 K.
More informationAddress: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K
Customer Company & Address: Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Contact Person: Mohit K Mittal Phone Number: +91 9811204494 Email Address: mohit@overdriveasia.com Relevant
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 2 1.5.2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 11 1/2 17 7/8 11 0 11 REPORT
More informationEquipment Used Model No Stock No Calibration Due Date
Report No: L091401801 Date: 9/16/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091401801 Report Prepared For: Olympia Lighting, inc. 50
More informationNVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006
LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)
More informationISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1.2.5 1 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 11 1/2 17 7/8 11 0.1.05.02.01.005
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L051603301 Date: 5/19/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L051603301 Report Prepared For: Colt LED Model Number: D12X6-GEN3-55W
More informationLM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:
LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationNVLAP LAB CODE:
REPORT NUMBER: RAB01271 PAGE: 1 OF 5 LUMINAIRE: LUMINAIRE: FABRICATED WHITE PAINTED METAL HOUSING, 4 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. LENS FROSTED SIDE UP. LAMPS:
More informationLM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806
More informationLM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50
LM-79-08 Test Report for Maxlite Inc. 12 York Ave West Caldwell NJ 07006 LED Canopy Model: MLCAN20LED50 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L071600301 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600301 Report Prepared For: Revolution Lighting Technologies
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L071600303 Date: 7/6/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071600303 Report Prepared For: Revolution Lighting Technologies
More informationClient submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.
Report No: L031500702 Date: 3/13/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031500702 Report Prepared For: EiKO Global, LLC 23220 W.
More informationModel No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02
Report No: L041608503 Date: 4/29/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041608503 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationLM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U
Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:
More informationPhotometric Test Report
Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L121404501R02 Date: 12/22/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121404501R02 Report Prepared For: Texas Fluorescents
More informationNVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)
LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,
More informationNumber Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000
Report No: L121706545 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121706545 Issue Date: 1/23/2018 Report Prepared For: Number Eight Lighting Company 526 Portal Street, Cotati,
More informationLM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS
LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 WALLPACK Model: MLSWP30LED50DS Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com
More informationChecked X.CAO
REPORT NUMBER: RAB02068 PAGE: 1 OF 7 CATALOG NUMBER: FXLED78SF - FXLED78T (SF=SLIPFITTER MOUNT & T=TRUNNION MOUNT) LUMINAIRE: CAST FINNED METAL HOUSING, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH AND
More informationPhotometric Test Report
Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com
More informationREVOLUTION LIGHTING TECHNOLOGIES INC
LM-79-08 Test Report For REVOLUTION LIGHTING TECHNOLOGIES INC (Brand Name: Revolution Lighting Technologies) 2280 Ward Ave, Simi Valley, CA 93065 Integrated Retrofit Kits for 2x4 Luminaires Model name(s):
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA High-bay Luminaires for Commercial and Industrial Buildings Model name(s): FI-HB-2FT-110W
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063
Report No: L121500506 Date: 12/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500506 Report Prepared For: Revolution Lighting Technologies
More informationChecked X.CAO
REPORT NUMBER: RAB01900 PAGE: 1 OF 7 CATALOG NUMBER: BULLET12Y LUMINAIRE: CAST FINNED METAL HEAT SINK, MOLDED TEXTURED PLASTIC REFLECTOR WITH SEMI-DIFFUSE FINISH, 1 CIRCUIT BOARD WITH 24 LEDS, CLEAR MICRO-PRISMATIC
More informationRevolution Lighting 4139 Guardian St. Simi Valley CA 93063
Report No: L121605937R02 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L121605937R02 Issue Date: 2/17/2017 Report Prepared For: Revolution Lighting 4139 Guardian St. Simi Valley
More information71332 LED Dusk To Dawn (Area Light)
71332 LED Dusk To Dawn (Area Light) 48 QPL ID # PK6ZRDD6 dusk-to-dawn photocell LM-79-08 Test Report For Morris Products Inc. (Brand Name: Morris) 53 Carey Road Queensbury, NY 12804 Outdoor Wall-Mounted
More informationLM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA
LM-79-08 Test Report For Revolution Lighting Technologies, Inc (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 113XS8-3LT Remark:
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Report No: L041609601 Date: 5/5/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041609601 Report Prepared For: GM LIGHTING 9830 W 190th St,
More informationBARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649
Report No: L101601204 Date: 10/18/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L101601204 Report Prepared For: BARTCO Lighting 5761 Research
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 01-10) Laboratory:
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 61-70) Laboratory:
More informationNVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires
LM-79-08 Test Report For Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): Remark: The suffix X can be A, B, B2, C, C2, D, D2, E, E2, F, F2 representing different mounting bracket; Y
More informationNVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ
LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540741XX(XX: 01-10) Laboratory:
More informationNVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA ) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Full-Cutoff Wall-mounted Area Luminaire Model
More informationLM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA
LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FI-CPL1212*603-50W-D
More informationLM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454
LM-79-08 Test Report For KEYSTONE TECHNOLOGIES LLC (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 1x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): KT-PLED40-14-830-VDIM
More informationNVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-30W Remark: X=CCT(4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits
More informationNVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS
LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th St., Shawnee, KS 66227. Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): WPT1-55/8XX-BZ-U Remark:The letter X in the model name stands
More informationNVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013
LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 High-bay Luminaires for Commercial and Industrial Buildings Model name(s): LED-9300-XXK Remark:
More informationLM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen
LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen High-bay Luminaires for Commercial and Industrial Buildings
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257
More informationNVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730
LM-79-08 Test Report For ATG ELECTRONICS CORP (Brand Name: N/A) 10700 7th Street Rancho Cucamonga, CA 91730 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FPEL24-40W-ZZ
More informationReport No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: L15T8SE450-G Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 125.1 1904.0 15.22 0.9679 CCT (K) CRI Stabilization Time (Light & Power)
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Full-Cutoff Wall-mounted Area Luminaire Model name(s): HC-WPC-40 Representative
More informationNVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101
LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-70W-30, LED2-ARD-70WD-30
More informationNVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101
LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-100W-30, LED2-ARD-100WD-30
More informationLM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503505 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503505 Report Prepared For: Revolution Lighting Technologies
More informationRevolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.
Report No: L111503504 Date: 11/18/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111503504 Report Prepared For: Revolution Lighting Technologies
More informationNVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ
LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson
More informationReport No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationNVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)
LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number 71462 UPC Number 60198671462 Description LED Vandal Resistant Canopy Light 40W Voltage: 120/277 Features Corrosion Die Cast Aluminum Housing Prismatic Polycarbonate Lens Superior Architectural
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 LED High Bay Light Model name(s): 502288##
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.
Test #: L08124408 Date:08/31/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L08124408 RR61430W Report Prepared For: MAXLITE
More informationNVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires
LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWP2-80W Remark:The letter X in the model name stands for CCT as bellow :3=3000K, 4=4000K, 5=5000K; YY stands for mounting
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires
More informationNVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006
LM-79-08 Test Report For MAXLITE,INC (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006 Direct Linear Ambient Luminaires Representative (Tested) Model: LSECO-4NU2050 Model Different: N/A Test & Report
More informationReport No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 LED Ceiling Light Model name(s): 544661##
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No. 1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China, 519085 LED Linear Ambient Light Model Name(s):
More informationReport No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light
More informationLM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)
LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED PAR30 Spot light Model: 524142XX(XX:41-50) Laboratory:
More informationNVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA
LM-79-08 Test Report For BEYOND LED TECHNOLOGY (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 USA HD FPB Series - High Definition Outdoor Corn Bulb Decorative Luminaires
More informationReport No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)
More informationNVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires
LM-79-08 Test Report For LED Waves, Inc. 4100 1st. Ave. Brooklyn, NY 11232 USA Linear Retrofit Kits for 2x2 Luminaires Model name(s): LWQR2x2-40W Representative (Tested) Model: LWQR2x2-40W-4000K LWQR2x2-40W-5000K
More informationQPL ID # PLG2YNJ831VZ
Catalog Number 71732 UPC Number 60198671732 Description UFO High Bay 100W Features Integral Cooling Fins Release Heat Efficiently Corrosion Resistant Die Cast Aluminum Housing Polycarbonate Lens Superior
More informationMorris Products 53 Carey Road, Queensbury, NY 12804
Catalog Number UPC Number Description 71466A 60198671466 LED Vandal Resistant Canopy Light 80W Voltage: 120/277 Features Corrosion Die Cast Aluminum Housing Prismatic Polycarbonate Lens Superior Architectural
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Low Bay Luminaires for Commercial and Industrial Buildings
More information(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary
Test Summary Sample Tested: LFC61541W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 63.3 988.8 15.61 0.9810 CCT Stabilization Time CRI (K) (Light & Power)
More informationLM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China
LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model
More informationLM Test Report
LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 Wall Pack Model name(s): 533041xx Representative
More information8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE
Test #: L12125907R02 Date: 1/14/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12125907R02 LR24-5000L-35K Report Prepared
More informationReport No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI
Test Summary Sample Tested: T8FR17/835/DIR/LED Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts)/2 Power Factor 105.4 1761.0 16.70 0.9970 CCT (K) CRI Stabilization Time (Light
More informationLM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A
LM-79-08 Test Report for Elec-Tech International Co., Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China BR40 LAMP Model: 525021XX(XX:01-10), WBR40L27S2A Laboratory:
More informationLM Test Report
LM-79-08 Test Report For IRICO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD Aotom LED Industrial Park, Qingzhuanhu Road 268, Huanggang, Hubei, China LED Panel Light Model name(s): 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH)
More information