LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Size: px
Start display at page:

Download "LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China"

Transcription

1 LM Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model name(s): W-XXK-WPH12-S Remark: "XXK" in the model name stands for different CCT as bellow: 40K=4000K,45K=4500K,50K=5000K,57K=5700K Representative (Tested) Model: W-40K-WPH12-S W-57K-WPH12-S Model Different: All construction and rating are the same, except CCT Test & Report By: Bill Luo Engineer: Bill Luo Date: Oct.09,2017 Review By: Manager: Tommy Liang Note: 1.The results contained in this report pertain only to the tested samples. 2.This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. 1 / 11

2 1.1 Product Information: Organization Name Eternal Shine Technology Co.,Ltd Brand Name EST Model Number W-XXK-WPH12-S SKU (if available) N/A Type of Luminaire (for integral lamps, list base type and lamp type) Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Rated Voltage / Frequency Vac, 60Hz Nominal Power 120W Rated Initial Lamp Lumen -- Declared CCT 4000K,4500K,5000K,5700K LED Manufacturer ShenZhen JuFei Optoelectronics Co., Ltd. LED Model V 1W White SMD LED Sample Number GZE H-B1(4000K), B2(5700K) Luminaire Aperture (for downlights) -- in. Luminaire Length -- mm Luminaires Width -- mm Number of Units (modular products) N/A s Photo 2 / 11

3 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard Reference Work Instruction Sep.28,2017 Oct.09, Total Luminous Flux 2. Luminous Distribution Intensity 3. Luminous Efficacy 4. Correlated Color Temperature 5. Color Rendering Index 6. Chromaticity Coordinate 7. Electrical Parameters 1. IES LM Electrical and Photometric Measurements of Solid-State Lighting Products 2. ANSI C Specifications for the Chromaticity of Solid State Lighting Products 3. CIE Method of Measuring and Specifying Colour Rendering Properties of Light Sources 4. CIE Technical Report Colorimetry 5. IESNA LM Practical Guide to Colorimetry of Light Source 6. IESNA TM Technical Memorandum on Light Emitting Diode (LED) Sources and Systems QD Test Methods 1) Photometric and Light Distribution Measurement Goniophotometer Method: Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25 C ± 1 C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1 vertical intervals and 22.5 horizontal intervals. 2) Chromaticity Measurement Sphere-Spectroradiometer Method: Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25ºC ± 1ºC. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral power distribution taken at 5 nm intervals over the range of 380 to 780 nm. 3) Electrical Measurements: Electrical parameters were measured using power meters incorporated in goniophotometer or sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at 25ºC ± 1ºC. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion were measured by and read from the power meter. 3 / 11

4 2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date Test Ambient: 25.2 ºC Test Orientation As intended Stabilization Time (min) 90 Model Number W-40K-WPH12-S Electrical Measurement: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE H-B DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement - Sphere-Spectroradiometer Method: Parameter Result Special Color Rendering Indices Test Voltage (V) R1 83 R9 16 Frequency (Hz) 60 R2 90 R10 75 CCT (K) 3964 R3 94 R11 81 Duv R4 82 R12 58 Chromaticity (x, y) x= y= R5 82 R13 85 Chromaticity (u, v ) u'= v'= R6 85 R14 97 Color Rendering Index (CRI) 83.8 R7 87 R15 77 R9 16 R Photometric Measurement Goniophotometer Method: Parameter Result DLC V4.2 Pass Criteria Test Voltage (V) Frequency (Hz) Total Luminous (lm) >=10000(-10%) Luminous Efficacy (lm/w) Total Luminous (lm)( 0-90 zone) Luminous Efficacy (lm/w) ( 0-90 zone) Most Worst Luminous/Highest Watts Zonal lumens in the zone 11.9 (%)( 0-90 zone) Standard: >= Premium: >= 100(-3%) 120(-3%) -- <= 10(+3) Beam Angle ( ) Center Beam Candle Power (cd) / 11

5 Spectral Power Distribution & Chromaticity Diagram Zonal Lumen Tabulation Zonal Lumen Summary Lumens Per Zone Zone Lumens % Luminaire Zone Lumens %Total Zone Lumens %Total , % , % , % , % , % , % , % , % , % % , % % % , % % , % % , % % , % % , % % , % % , % % 5 / 11

6 Photometric Data 6 / 11

7 7 / 11

8 2.2 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25) Test date Test Ambient: 25.2 ºC Test Orientation As intended Stabilization Time (min) 90 Model Number W-57K-WPH12-S Electrical Measurement: Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD % GZE H-B DLC Pass Criteria >= 0.9(-3%) <= 20(+5) Chromaticity Measurement - Sphere-Spectroradiometer Method: Parameter Result Special Color Rendering Indices Test Voltage (V) R1 84 R9 20 Frequency (Hz) 60 R2 89 R10 72 CCT (K) 5457 R3 91 R11 83 Duv R4 84 R12 57 Chromaticity (x, y) x= y= R5 84 R13 85 Chromaticity (u, v ) u'= v'= R6 83 R14 95 Color Rendering Index (CRI) 84.4 R7 88 R15 81 R9 20 R Photometric Measurement Sphere-Spectroradiometer Method: Parameter Result DLC V4.2 Pass Criteria Test Voltage (V) Frequency (Hz) Total Luminous (lm) >=10000(-10%) Luminous Efficacy (lm/w) Total Luminous (lm)( 0-90 zone) Luminous Efficacy (lm/w) ( 0-90 zone) Most Worst Luminous/Highest Watts Standard: >= Premium: >= 100(-3%) 120(-3%) 8 / 11

9 Spectral Power Distribution & Chromaticity Diagram 9 / 11

10 2.3 Performance Assessment: Model name CCT(K) Total Luminous Luminous Power (W) (lm) Efficacy (lm/w) W-40K-WPH12-S 4000K W-45K-WPH12-S 4500K * * * W-50K-WPH12-S 5000K * * * W-57K-WPH12-S 5700K *1: This value is calculated and the calculation formula is as below: 14149=( )/ =( )/ *2: This value is calculated and the calculation formula is as below: 115.1=( )/2 *3: This value is calculated and the calculation formula is as below: =14149/ =14304/ / 11

11 3. Test Equipment Equipment ID Equipment Name Last Calibration Date Next Calibration Date ST-R meter Integrating Sphere ST-R-327 Spectral analysis system HAAS D204 Standard Lamp PF2010 Power Meter for Integrating Sphere GO-R5000 Goniophotometer system D908S Standard Lamp PF210 Power Meter for Goniophotometer Expand Uncertainty: Photometric Measurement (Sphere):2.04%, k=2 Chromaticity Measurement(Sphere):28.8K, k=2 Photometric Measurement(Goniophotometer):2.36%, k=2 ****** END OF REPORT ****** 11 / 11

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model

More information

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted Area Luminaires Model

More information

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model

More information

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 LM-79-08 Test Report For KEYSTONE TECHNOLOGIES LLC (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454 1x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): KT-PLED40-14-830-VDIM

More information

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen High-bay Luminaires for Commercial and Industrial Buildings

More information

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China LM-79-08 Test Report For Eternal Shine Technology Co.,Ltd (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Low Bay Luminaires for Commercial and Industrial Buildings

More information

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA ) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Outdoor Full-Cutoff Wall-mounted Area Luminaire Model

More information

REVOLUTION LIGHTING TECHNOLOGIES INC

REVOLUTION LIGHTING TECHNOLOGIES INC LM-79-08 Test Report For REVOLUTION LIGHTING TECHNOLOGIES INC (Brand Name: Revolution Lighting Technologies) 2280 Ward Ave, Simi Valley, CA 93065 Integrated Retrofit Kits for 2x4 Luminaires Model name(s):

More information

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG 57-100W-XXK-WPH12-SG 57-100W-40K-WPH12-SG 57-100W-57K-WPH12-SG Eternal Shine Technology Co.,Ltd. EST 57-100W-XXK-WPH12-SG 1.2 Test Specifications: Date of Receipt Date of Test Test item Reference Standard

More information

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-30W Remark: X=CCT(4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits

More information

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W LM-79-08 Test Report Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): WML-50W Representative (Tested) Model: WML-50NW WML-50CW Model Different: All construction and rating

More information

Eternal Shine Technology Co.,Ltd. EST

Eternal Shine Technology Co.,Ltd. EST Eternal Shine Technology Co.,Ltd. EST NO.7 Flood, Bldg A,Shenfubao Industry Park, Bonded area, Futian District,Shenzhen, China 57-40W-XXK-WPH06-SG 57-40W-40K-WPH06-SG 57-40W-57K-WPH06-SG Eternal Shine

More information

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWA-50W Remark: X=CCT(3=3000K,4=4000K,5=5000K) YY=Mounting Option(WM=Wall Mount) ZZ=Housing Color(use 2 digits to indicate

More information

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA High-bay Luminaires for Commercial and Industrial Buildings Model name(s): FI-HB-2FT-110W

More information

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA LM-79-08 Test Report For Revolution Lighting Technologies, Inc (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 113XS8-3LT Remark:

More information

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA LM-79-08 Test Report For FALKOR INDUSTRY INC (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA 90201 USA 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FI-CPL1212*603-50W-D

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013 High-bay Luminaires for Commercial and Industrial Buildings Model name(s): LED-9300-XXK Remark:

More information

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires LM-79-08 Test Report For Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): Remark: The suffix X can be A, B, B2, C, C2, D, D2, E, E2, F, F2 representing different mounting bracket; Y

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A) LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730 LM-79-08 Test Report For ATG ELECTRONICS CORP (Brand Name: N/A) 10700 7th Street Rancho Cucamonga, CA 91730 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): FPEL24-40W-ZZ

More information

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA LM-79-08 Test Report For BEYOND LED TECHNOLOGY (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084 USA HD FPB Series - High Definition Outdoor Corn Bulb Decorative Luminaires

More information

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th St., Shawnee, KS 66227. Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): WPT1-55/8XX-BZ-U Remark:The letter X in the model name stands

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A) LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Full-Cutoff Wall-mounted Area Luminaire Model name(s): HC-WPC-40 Representative

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A) LM-79-08 Test Report For HOCAN GROUP CO LTD (Brand Name: N/A) Rm 1902, Easet cinn Bldg 253-261 Hennessy Rd Wanchai,HongKong Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-70W-30, LED2-ARD-70WD-30

More information

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 LM-79-08 Test Report For LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Model name(s): LED2-ARD-100W-30, LED2-ARD-100WD-30

More information

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWP2-80W Remark:The letter X in the model name stands for CCT as bellow :3=3000K, 4=4000K, 5=5000K; YY stands for mounting

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Fuel Pump Canopy Luminaires Model name(s): TLCLB80XYYZZ

More information

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE) LM-79-08 Test Report For Torshare Ltd. (Brand Name: TORSHARE) 5th Minying Road No.3 Industrial Area Shuitian Shiyan Town Bao'an District,Shenzhen Guangdong 518108 China Direct Linear Ambient Luminaires

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

More information

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires LM-79-08 Test Report For LED Waves, Inc. 4100 1st. Ave. Brooklyn, NY 11232 USA Linear Retrofit Kits for 2x2 Luminaires Model name(s): LWQR2x2-40W Representative (Tested) Model: LWQR2x2-40W-4000K LWQR2x2-40W-5000K

More information

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006 LM-79-08 Test Report For MAXLITE,INC (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006 Direct Linear Ambient Luminaires Representative (Tested) Model: LSECO-4NU2050 Model Different: N/A Test & Report

More information

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 LM-79-08 Test Report For Maxlite INC (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): MLFP24EP50XX Remark: The

More information

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)

More information

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0. LED Wall-PACK/Flood Light Data Sheet Cat# 71152 Direct to wall RoHS Wet Locations Use QPL ID # PLUV5PQHJX3Z Model: 71152 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Input Voltage

More information

Dimming: PWM/TIME/0-5V/0-10V. RoHS

Dimming: PWM/TIME/0-5V/0-10V. RoHS Dimming: PWM/TIME/0-5V/0-10V Cat# 71575A 150 Watts Pole Mount RoHS QPL ID # PLMWEKHWJOBH Model: 71575A OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance

More information

Cat# 71440A LED Classic Large Wall-Pack

Cat# 71440A LED Classic Large Wall-Pack Cat# 71440A LED Classic Large Wall-Pack Dimming: 0-10V/PWM/VR QPL ID # PL8EA2B65DY8 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ LM-79-08 Test Report For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO61840W Representative (Tested) Model: RRECO61840W Test & Report By: Johnson

More information

QPL ID # PLG2YNJ831VZ

QPL ID # PLG2YNJ831VZ Catalog Number 71732 UPC Number 60198671732 Description UFO High Bay 100W Features Integral Cooling Fins Release Heat Efficiently Corrosion Resistant Die Cast Aluminum Housing Polycarbonate Lens Superior

More information

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90 Cat# 71554 30 Watts 1/2" Knuckle Mount RoHS QPL ID # PHNRJ3EY Model: 71554 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI

More information

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish: Catalog Number UPC Number Description 71452 60198671452 Dark Sky Wallpack 50W Features Full Cutoff Design to Prevent Up Light Integral Cooling Fins Release Heat Efficiently Corrosion Resistant Die Cast

More information

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens Cat# 71552 15 Watt 1/2" Adjustable Knuckle Mount RoHS QPL ID # P4K7RKA9 Model: 71552 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency

More information

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS Cat# 71543 150 Watts Trunion Mount RoHS QPL ID # PF9T16AA Model: 71543 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam

More information

RoHS QPL ID # PLC6V1PABNUJS

RoHS QPL ID # PLC6V1PABNUJS Cat# 71836 220 Watts Trunion Mount RoHS QPL ID # PLC6V1PABNUJS OVERALL LAMP PARAMETERS LED DRIVER LED Input Power Power Factor Luminance Luminous Efficiency CRI R9 8 Beam Angle Main Structure Output Voltage

More information

Cat# LED High Bay

Cat# LED High Bay Cat# 71402 LED High Bay QPL ID # PPXEAWS8 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: 71402 Input Voltage 100-277VAC 50/60HZ Input Current 1.2A Max Input Power 100 W

More information

Morris Products 53 Carey Road, Queensbury, NY 12804

Morris Products 53 Carey Road, Queensbury, NY 12804 Catalog Number UPC Number Description 71466A 60198671466 LED Vandal Resistant Canopy Light 80W Voltage: 120/277 Features Corrosion Die Cast Aluminum Housing Prismatic Polycarbonate Lens Superior Architectural

More information

LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

LM Test Report. For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED) LM-79-08 Test Report For SHENZHEN SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Floor 3rd/4th/5th/6th Block6, Block21, Zhengdaan Industry Park No 172 Xiangshan Rd, Luotian Village Songgang Town, Baoan

More information

RoHS. Model: VAC 50/60HZ.83A Max 100W

RoHS. Model: VAC 50/60HZ.83A Max 100W Cat# 71542 100 Watts Trunion Mount RoHS UL/CUL TUV-CE QPL ID # PTX2Q1C3 Model: 71542 Input Voltage Input Current Input Power 100-277VAC 50/60HZ.83A Max 100W OVERALL LAMP PARAMETERS LED DRIVER LED Power

More information

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A 71345A 50W LED Floodlight Yoke(Bracket) Mount RoHS QPL ID # PLDUWHES4P5Q Model: Input Voltage Input Current Input Power Power Factor OVERALL LAMP Luminance PARAMETERS Luminous Efficiency CRI Beam Angle

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

Cat# 71146A 150W Trunion Mount

Cat# 71146A 150W Trunion Mount Cat# 71146A 150W Trunion Mount RoHS Dimming: 0-10V/PWM/VR QPL ID # PLZOBKAFGDBR Model: 71146A Input Voltage 120-277 VAC 50/60HZ Input Current 1.7A MAX Input Power 150W Power Factor PF 0.90 OVERALL LAMP

More information

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG LM-79-08 Test Report For Hocan Group Co.,Ltd (Brand Name: SEPICN LED Lighting) Rm 1902, Easey Comm Bldg 253-261 Hennessy Rd Wanchai, HONG KONG LED Tube Light Model name(s): HC-T8-8FT-36W-ID(Clear) Representative

More information

71352A QPL ID # PLT2P2L2UNWR. RoHS

71352A QPL ID # PLT2P2L2UNWR. RoHS Dimming: 0-10V/PWM/VR 71352A 80W LED Floodlight Trunnion Mount Model: RoHS 71352A QPL ID # PLT2P2L2UNWR Input Voltage 100-277AC 50/60HZ Input Current 1.00A MAX Input Power 80 W Power Factor PF 0.90 OVERALL

More information

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount.  Model: master carton: L*W*Hmm 1PCS. EPA Rating 1. Cat# 71544 220 Watts Trunion Mount Model: 71544 RoHS QPL ID # P9JSE2P8 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam

More information

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB Cat# 71541 80 Watts Trunion Mount RoHS QPL ID # PNZ72BAB OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure

More information

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB Cat# 71561 80 Watts Slipfitter Mount Model: 71561 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure

More information

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount.   EPA Rating 2.33ft 2. Cat# 71896 380W FlatPanel Pole Mount Model: 71896 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure

More information

Cat# LED Classic MINI Wall-PACK

Cat# LED Classic MINI Wall-PACK Cat# 71418 LED Classic MINI Wall-PACK QPL ID # PL08MT480BZK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC OTHERS Model: Input Voltage Input Current Input Power Power Factor Luminance

More information

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69 Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69 OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI

More information

www.greenelectricalsupply.com Cat# 71855 220 Watts Pole Mount RoHS UL/CUL TUV-CE QPL ID # PLTP6C Q97 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance

More information

www.greenelectricalsupply.com P 0 0 0 Cat# 71574A 100 Watts Pole Mount RoHS QPL ID # PLV5YTKQ0SQJ OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous

More information

71332 LED Dusk To Dawn (Area Light)

71332 LED Dusk To Dawn (Area Light) 71332 LED Dusk To Dawn (Area Light) 48 QPL ID # PK6ZRDD6 dusk-to-dawn photocell LM-79-08 Test Report For Morris Products Inc. (Brand Name: Morris) 53 Carey Road Queensbury, NY 12804 Outdoor Wall-Mounted

More information

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD) LM-79-08 Test Report For SHENZHEN BONLD ELECTRONICS CO.,LTD (Brand Name: BONLD) Bldg2-5, TongFuYu Industrial Park, Aiqun Road, Shiyan Town, Bao an District, Shenzhen, China 1x4 Luminaires for Ambient Lighting

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING) LM-79-08 Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name: OKT LIGHTING) NO.2076 Jincheng Rd,Shajing Town, Bao'an District, Shenzhen, China. SSL downlight retrofits Model name(s): CE6-40W-XXE

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING) LM-79-08 Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name: OKT LIGHTING) NO.2076 Jincheng Rd,Shajing Town, Bao'an District, Shenzhen, China. SSL downlight retrofits Model name(s): C10-D54W-XXE

More information

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD Energy Star Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name:OKT Lighting) NO.2076 Jincheng Rd, Shajing Town, Bao an District,Shenzhen, China SSL downlight retrofits Model name(s):c10-d40w-30e

More information

LM Test Report. For. Beyond LED Technology Parker Ct Stone Mountain, GA Epic Series LED Pole Light

LM Test Report. For. Beyond LED Technology Parker Ct Stone Mountain, GA Epic Series LED Pole Light LM-79-08 Test Report For Beyond LED Technology (Brand Name: Beyond LED) 1939 Parker Ct Stone Mountain, GA 30087 Epic Series LED Pole Light Model name(s): BLT-XSB-300W-50K-TPIII-SBA Remark: XXK stands for

More information

Cat# LED Wall-PACK

Cat# LED Wall-PACK Cat# 71426 LED Wall-PACK OVERALL LAMP PARAMETERS LED DRIVER LED LIFESPAN & ENVIRONMENT SAFETY&EMC Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle

More information

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

LED Floodlight. RoHS. Model: inner box: L 17 X W 12.5 X H 9.33 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W. 71352 LED Floodlight RoHS Model: 71352 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage

More information

LM Test Report

LM Test Report LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 Wall Pack Model name(s): 533041xx Representative

More information

LM Test Report

LM Test Report LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 LED Ceiling Light Model name(s): 544661##

More information

LM Test Report

LM Test Report LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No.1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R. China 519085 LED High Bay Light Model name(s): 502288##

More information

LM Test Report

LM Test Report LM-79-08 Test Report For IRICO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD Aotom LED Industrial Park, Qingzhuanhu Road 268, Huanggang, Hubei, China LED Panel Light Model name(s): 22AP3235A (CLC/WLC FPL22-835-32W-130LW-UNV-DIM1-WH)

More information

LM Test Report

LM Test Report LM-79-08 Test Report For ELEC-TECH INTERNATIONAL CO LTD No. 1 Jinfeng Road, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China, 519085 LED Linear Ambient Light Model Name(s):

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Catalog Number IGTTU-2102550G-4T5

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com

More information

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K Customer Company & Address: Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Contact Person: Mohit K Mittal Phone Number: +91 9811204494 Email Address: mohit@overdriveasia.com Relevant

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards RIES LM-79-2008 RANSI C82.77:2014 Prepared For RAB LIGHTING INC 170 Ludlow Ave, PO BOX 970, Northvale, NJ 07647-2305 USA Crystal Wu 13482123342, Crystal.Wu@rabweb.com

More information

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A LM-79-08 Test Report for Elec-Tech International Co., Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China BR40 LAMP Model: 525021XX(XX:01-10), WBR40L27S2A Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 01-10) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540751XX(XX: 61-70) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED CEILING LIGHT Model: 540741XX(XX: 01-10) Laboratory:

More information

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50) LM-79-08 Test Report for Elec-Tech International Co.,Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China LED PAR30 Spot light Model: 524142XX(XX:41-50) Laboratory:

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 Prepared For MaxLite Inc 0 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x46, rraghavan@maxlite.com Test Laboratory & Address:

More information

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report for EiKO Global, LLC 23220 W. 84th St. Shawnee, KS 66227 25W Floodlight Model: FLM-2C-N-U Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50 LM-79-08 Test Report for Maxlite Inc. 12 York Ave West Caldwell NJ 07006 LED Canopy Model: MLCAN20LED50 Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com

More information

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model: LM-79-08 Test Report for Philips (China) Investment Co., Ltd. Building 9, Lane 888, Tianlin Road Shanghai, China InstantFit LEDtube Model: 9290002840 Laboratory: Leading Testing Laboratories NVLAP CODE:

More information

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 WALLPACK Model: MLSWP30LED50DS Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com

More information

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV LM-79-08 Test Report for Maxlite SK America Inc. 12 York Ave West Caldwell NJ 07006 2*4 Retrofit Kits Model: RKT4514U5550DV Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806

More information

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co. IESNA SUSTAINING MEMBER Test report of IES LM-79-08 Ref. No.: LCGP14100013 Date of issue Oct 18, 2014 Version 1.0 Total pages: 11 Approved Method: Electrical and Photometric Measurements of Solid-State

More information

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary Test Summary Sample Tested: LFC41327W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 45.3 544.6 12.02 0.9892 CCT Stabilization Time CRI (K) (Light & Power)

More information

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLLWP40LED50DS Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 96.2 3353.0 34.85 0.9900 CCT (K) CRI Stabilization Time (Light & Power)

More information

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: WPL40AU50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 91.6 3480.4 37.99 0.9907 CCT (K) CRI Stabilization Time (Light & Power) 5257

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: LDP2450L35U1 2X4 3500K Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 102.3 5129.5 50.12 0.9883 CCT (K) CRI Stabilization Time (Light

More information

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary Test Summary Sample Tested: LFC61541W/V2 Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 63.3 988.8 15.61 0.9810 CCT Stabilization Time CRI (K) (Light & Power)

More information

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products IESNA SUSTAINING MEMBER Ref. No.: LCZP15060026 Date of issue June 5, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)

More information

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products IESNA SUSTAINING MEMBER Date of issue Mar 17, 2015 Version 1.0 Total pages: 11 Test report of IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products Rendered

More information

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light

More information