EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments
|
|
- Roger Walters
- 5 years ago
- Views:
Transcription
1
2
3 EMC Page 3 / 33 Test report No.: EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: Ambient conditions: Ambient temperature: 18 C Relative humidity: 60 % Air pressure 1006 hpa Test setup: Laboratory test Post-installation test Classification of equipment: --- Measuring method: Tested: Disturbance voltage Frequency range 150 khz - 30 MHz (see measurement results on page 4-7) Radiated disturbance Frequency range 30 MHz MHz (could not be measured, see on page 8) Calculated measurement uncertainty for Disturbance voltage: ± 2.34 db k= Radiated disturbances (30 MHz 200 MHz): ± 4.73 db k= 2 Radiated disturbance (200 MHz 1000 MHz): ± 4.86 db k= 2 Evaluation based on the test results: Passed Failed Note(s): The measurement was performed on the place of applicant.
4 EMC Page 4 / 33 Test report No.: EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Measurement of disturbance voltage in the frequency range between 150 khz and 30 MHz: Description of operating conditions applied for testing of the product (settings, load, program, etc.): Test point: The test sample was continuously operated AC power port Line L1 Disturbance voltage diagram: As the measurement was not performed in a shielded chamber, there are peaks shown on diagram, which derive not from EUT (which derive from external source). The peak on 540 khz for example is a broadcasting radostation.
5 EMC Page 5 / 33 Test report No.: EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Measurement of disturbance voltage in the frequency range between 150 khz and 30 MHz: Description of operating conditions applied for testing of the product (settings, load, program, etc.): Test point: The test sample was continuously operated AC power port Line L2 Disturbance voltage diagram: As the measurement was not performed in a shielded chamber, there are peaks shown on diagram, which derive not from EUT (which derive from external source). The peak on 540 khz for example is a broadcasting radostation.
6 EMC Page 6 / 33 Test report No.: EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Measurement of disturbance voltage in the frequency range between 150 khz and 30 MHz: Description of operating conditions applied for testing of the product (settings, load, program, etc.): Test point: The test sample was continuously operated AC power port Line L3 Disturbance voltage diagram: As the measurement was not performed in a shielded chamber, there are peaks shown on diagram, which derive not from EUT (which derive from external source). The peak on 540 khz for example is a broadcasting radostation.
7 EMC Page 7 / 33 Test report No.: EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Measurement of disturbance voltage in the frequency range between 150 khz and 30 MHz: Description of operating conditions applied for testing of the product (settings, load, program, etc.): Test point: The test sample was continuously operated AC power port Neutral Disturbance voltage diagram: As the measurement was not performed in a shielded chamber, there are peaks shown on diagram, which derive not from EUT (which derive from external source). The peak on 540 khz for example is a broadcasting radostation.
8 EMC Page 8 / 33 Test report No.: EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Measurement of radiated disturbances in the frequency range between 30 MHz and 1 GHz: Description of operating conditions applied for testing of the product (settings, load, program, etc.): Test point: Description of measurement area: Measurement distance: Height of antenna: Polarisation of antenna Description of cables: Measurement results: The test sample was continuously operated Enclosure port. The measurement was carried out on site, at the place of manufacturer 10 m 1-4 m Vertical, horizontal. Power supply cable, 5x6 mm 2, 8 m long Valuable disturbance field strength could not be measured. Frequency MHz Measured value dbµv Ambient noise dbµv/m Actual disturbance level dbµv/m Limit value (for 10 m) dbµv/m Polarisation of the antenna v / h Note(s): ---
9 EMC Page 9 / 33 Test report No.: Test instruments used: EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Denomination Manufacturer Type Serial No. Next calibration Applied Measuring receiver R & S ESCS / Measuring receiver NARDA WX WX Artificial mains network R & S ESH3-Z / Artificial mains network Schwarzbeck NNLK Pulse limiter R & S ESH3-Z Biconical antenna Emco Log.-per. antenna Emco Biconilog antenna ETS-Lindgren 3142 c Photo(s) on the measuring arrangement:
10 EMC Page 10 / 33 Test report No.: EN :2006+A1:2009+A2:2009 Harmonic current Date of measurement: Ambient conditions: Ambient temperature: 21 C Relative humidity: 53 % Air pressure: 1013 hpa Test setup: Laboratory test: Post-installation test: Calculated measurement uncertainty for harmonic current: ± 0.25 % k= 2 Evaluation based on the test results: Passed Failed Note: The measurement was performed on the place of applicant.
11 EMC Page 11 / 33 Test report No.: EN :2006+A1:2009+A2:2009 Harmonic current Operating conditions: Description of operating conditions applied for testing of the product (settings, load, program, etc.): The test sample was continuously operated Allowed max. values of harmonic current of class A equipment: Harmonic No. Limit for harmonic current Odd harmonics n x (15 / n) Even harmonics n x (8 / n) Test point: mains connection Note(s): ---
12 EMC Page 12 / 33 Test report No.: EN :2006+A1:2009+A2:2009 Harmonic current Measuring on main terminal Neutral Voltage = V Voltage Distortion = 2.69 % Current = A Current Distortion = 5.37 % Power = W Apparent Power = VA CosPhi(1)= Power Factor = Phase = L1 Hn I rms Percentage Phase Limits FAIL DC A % no limit A % no limit A 1.06 % A A 1.68 % A A 0.16 % A A 4.19 % A A 0.11 % A A 2.59 % A A 0.11 % A A 0.10 % A A 0.13 % A A 0.08 % A A 0.11 % A A 0.44 % A A 0.11 % A A 0.09 % A A 0.11 % A A 0.25 % A A 0.11 % A A 0.15 % A A 0.11 % A A 0.06 % A A 0.10 % A A 0.16 % A A 0.15 % A A 0.10 % A A 0.09 % A A 0.08 % A A 0.08 % A A 0.08 % A A 0.10 % A A 0.04 % A A 0.07 % A A 0.07 % A A 0.07 % A A 0.05 % A A 0.06 % A A 0.04 % A A 0.05 % A A 0.04 % A A 0.05 % A A 0.05 % no limit A 0.05 % no limit A 0.05 % no limit A 0.05 % no limit A 0.03 % no limit A 0.04 % no limit A 0.04 % no limit A 0.04 % no limit A 0.04 % no limit A 0.03 % no limit
13 EMC Page 13 / 33 Test report No.: EN :2006+A1:2009+A2:2009 Harmonic current Test instruments used: Denomination Manufacturer Type Serial No. Next calibration Applied Digital flickermeter- Real time harmonic analyser PMM PMM 1000 H Power supply Kikusui PCR 2000L A Power supply Kikusui PCR 2000L A Power supply Kikusui PCR 2000L A Digital multimeter Norma MP 14 X529116C Clamp on probe HIOKI Additional information: * The power supplies are not calibrated instruments. Their output parameters are checked during each measurement. Photo(s) on the measuring arrangement:
14 EMC Page 14 / 33 Test report No.: EN :2009 Immunity against electrostatic discharges Date of measurement: Ambient conditions: Ambient temperature: 18 C Relative humidity: 60 % Air pressure 1006 hpa Test setup: Laboratory test Post-installation test Calculated measurement uncertainty measurement uncertainty of current measurement: 2,5 %, k= 2 measurement uncertainty of time measurement: ± 110ps, k= 2 Evaluation based on the test results: Passed Failed Note(s): The measurement was performed on the place of applicant.
15 EMC Page 15 / 33 Test report No.: Operating conditions: EN :2009 Immunity against electrostatic discharges Description of operating conditions applied for testing of the product (settings, load, program, etc.): The test sample was continuously operated Performance criterion A Normal operation within the prescribed limits. Test voltage: 4 kv B C After a temporary degradation or failure of function the normal operation is restored automatically. After a temporary degradation or failure of function the normal operation is restored by the operator's action. Number of discharges: Method of discharges: 10 positive + 10 negative, each of tested points. Direct and indirect contact discharge. Place of discharges (tested points): Metallic parts of EUT, vertical and horisontal coupling plane. Operation of the EUT during the test: No change was observed in the operation of the equipment. Performance criterion is complied with A'. Note(s): Test level and performance criterion are specified in EN :2007 standard. Photo(s) on the measuring arrangement:
16 EMC Page 16 / 33 Test report No.: Operating conditions: EN :2009 Immunity against electrostatic discharges Description of operating conditions applied for testing of the product (settings, load, program, etc.): The test sample was continuously operated Performance criterion A Normal operation within the prescribed limits. Test voltage: 8 kv B C After a temporary degradation or failure of function the normal operation is restored automatically. After a temporary degradation or failure of function the normal operation is restored by the operator's action. Number of discharges: Method of discharges: 10 positive + 10 negative, each of tested points. Air discharge. Place of discharges (tested points): Display and the plastic enclosure of the appliance. Operation of the EUT during the test: No change was observed in the operation of the equipment. Performance criterion is complied with A'. Note(s): Test level and performance criterion are specified in EN :2007 standard. Photo(s) on the measuring arrangement:
17 EMC Page 17 / 33 Test report No.: Test instruments used: EN :2009 Immunity against electrostatic discharges Denomination Manufacturer Type Serial No. Next calibration Applied ESD generator EMC-Partner ESD Note(s): ---
18 EMC Page 18 / 33 Test report No.: EN : A1: A2:2010 Radiated, radio-frequency, electromagnetic field immunity test Date of measurement: Ambient conditions: Ambient temperature: 18 C Relative humidity: 59 % Air pressure 1006 hpa Test setup: Laboratory test Post-installation test Calculated measurement uncertainty for radiated, radio-frequency electromagnetic fields: ±1.52 dbm k=1.64 Evaluation based on the test results: Passed Failed Note(s): The measurement was performed on the place of applicant.
19 EMC Page 19 / 33 Test report No.: Operating conditions: EN : A1: A2:2010 Radiated, radio-frequency, electromagnetic field immunity test Description of operating conditions applied for testing of the product (settings, load, program, etc.): The test sample was continuously operated Performance criterion A Normal operation within the prescribed limits. B C After a temporary degradation or failure of function the normal operation is restored automatically. After a temporary degradation or failure of function the normal operation is restored by the operator's action Frequency range: MHz GHz GHz Field strength: 3 V/m 3 V/m 1 V/m Modulation: 80 % AM; 1kHz 80 % AM; 1kHz 80 % AM; 1kHz Frequency step: 0.25 % 0.25 % 0.25 % Dwell time 1 s 1 s 1 s Operation of the EUT during the test: No change was observed in the operation of the equipment. Performance criterion is complied with A'. Note(s): Test level and performance criterion are specified in EN :2007 standard. Photo(s) on the measuring arrangement:
20 EMC Page 20 / 33 Test report No.: Test instruments used: EN : A1: A2:2010 Radiated, radio-frequency, electromagnetic field immunity test Denomination Manufacturer Type Serial No. Next calibration Applied Semi anechoic chamber T-Network 3, 10 m Signal generator R&S SMT Signal generator R&S SMY / Power amplifier AR 25A250A Power amplifier Ophir 5127F Power amplifier Bonn BSA B Power amplifier Bonn BLWA B Power amplifier Bonn BLMA Power Amplifier Bonn BLMA Portable field strength meter Antenna for measurement of field strength Optic repeater (for BA01) PMM J PMM BA J PMM OR K Biconical antenna Emco Log.-per. antenna Emco Biconilog antenna ETS-Lindgren 3142 c Note(s): ---
21 EMC Page 21 / 33 Test report No.: EN :2012 Electrical fast transient/burst immunity test Date of measurement: Ambient conditions: Ambient temperature: 22 C Relative humidity: 46 % Air pressure 1013 hpa Test setup: Laboratory test Post-installation test Evaluation based on the test results: Passed Failed Note(s): The measurement was performed on the place of applicant.
22 EMC Page 22 / 33 Test report No.: Operating conditions: EN :2012 Electrical fast transient/burst immunity test Description of operating conditions applied for testing of the product (settings, load, program, etc.): The test sample was continuously operated. The test was carried out on the mains wires of the control electronics only. Performance criterion A Normal operation within the prescribed limits. B C After a temporary degradation or failure of function the normal operation is restored automatically. After a temporary degradation or failure of function the normal operation is restored by the operator's action. Test voltage: Test pulse (T r /T h ): Repetition frequency: Burst duration: Burst period: Polarity: Duration of test: Coupling method: Place of coupling: 1 kv 5 / 50 ns 5 khz 15 ms 300 ms Positive, then negative. 120 s (positive) s (negative). CDN (built in) AC power port mains connection Operation of the EUT during the test: No change was observed in the operation of the equipment. Performance criterion is complied with A'. Note(s): Test level and performance criterion are specified in EN :2007 standard. Photo on the measuring arrangement:
23 EMC Page 23 / 33 Test report No.: Test instruments used: EN :2012 Electrical fast transient/burst immunity test Denomination Manufacturer Type Serial No. Next calibration Applied Combined generator EM test UCS phase CDN Schaffner CDN phase CDN Haefely FP 16/ Capacitive coupler Haefely Note(s): ---
24 EMC Page 24 / 33 Test report No.: EN :2006 Immunity against surges Date of measurement: Ambient conditions: Ambient temperature: 22 C Relative humidity: 46 % Air pressure 1013 hpa Test setup: Laboratory test Post-installation test Evaluation based on the test results: Passed Failed Note(s): The measurement was performed on the place of applicant.
25 EMC Page 25 / 33 Test report No.: EN :2006 Immunity against surges Operating conditions: Description of operating conditions applied for testing of the product (settings, load, program, etc.): The test sample was continuously operated. The test was carried out on the mains wires of the control electronics only. Performance criterion A Normal operation within the prescribed limits. B C After a temporary degradation or failure of function the normal operation is restored automatically. After a temporary degradation or failure of function the normal operation is restored by the operator's action. Test voltage: 1 kv Test pulse (open circuit, T r /T h ): 1.2 / 50 µs Test pulse (short circuit, T r /T h ): 8 / 20 µs Number of pulses: 10 positive + 10 negative each at 0, 90, 180, Time between impulses Coupling method: Place of coupling: 60 s CDN (built in). AC power port mains connection: L N (differential mode). Operation of the EUT during the test: No change was observed in the operation of the equipment. Performance criterion is complied with A'. Note(s): Test level and performance criterion are specified in EN :2007 standard.
26 EMC Page 26 / 33 Test report No.: EN :2006 Immunity against surges Operating conditions: Description of operating conditions applied for testing of the product (settings, load, program, etc.): The test sample was continuously operated. The test was carried out on the mains wires of the control electronics only. Performance criterion A Normal operation within the prescribed limits. B C After a temporary degradation or failure of function the normal operation is restored automatically. After a temporary degradation or failure of function the normal operation is restored by the operator's action. Test voltage: 2 kv Test pulse (open circuit, T r /T h ): 1.2 / 50 µs Test pulse (short circuit, T r /T h ): 8 / 20 µs Number of pulses: 10 positive + 10 negative each at 0, 90, 180, Time between impulses Coupling method: Place of coupling: 60 s CDN (built in). AC power port mains connection: L+N PE (common mode). Operation of the EUT during the test: No change was observed in the operation of the equipment. Performance criterion is complied with A'. Note(s): Test level and performance criterion are specified in EN :2007 standard.
27 EMC Page 27 / 33 Test report No.: EN :2006 Immunity against surges Test instruments used: Denomination Manufacturer Type Serial No. Next calibration Applied Combined generator EM test UCS Note(s): --- Photo(s) on the measuring arrangement:
28 EMC Page 28 / 33 Test report No.: EN :2009 Immunity to conducted disturbances, induced by radiofrequency fields Date of measurement: Ambient conditions: Ambient temperature: 18 C Relative humidity: 56 % Air pressure 1013 hpa Test setup: Laboratory test Post-installation test Evaluation based on the test results: Passed Failed Note(s): The measurement was performed on the place of applicant.
29 EMC Page 29 / 33 Test report No.: Operating conditions: EN :2009 Immunity to conducted disturbances, induced by radiofrequency fields Description of operating conditions applied for testing of the product (settings, load, program, etc.): The test sample was continuously operated. The test was carried out on the mains wires of the control electronics only. Performance criterion A Normal operation within the prescribed limits. B C After a temporary degradation or failure of function the normal operation is restored automatically. After a temporary degradation or failure of function the normal operation is restored by the operator's action Frequency range: RF voltage: MHz 3 V Step size: 0.25 % Dwell time: Modulation: Coupling method: Place of coupling: 1 s 80 % AM; 1 khz CDN type M3 AC power port mains connection. Operation of the EUT during the test: No change was observed in the operation of the equipment. Performance criterion is complied with A'. Note(s): Test level and performance criterion are specified in EN :2007 standard.
30 EMC Page 30 / 33 Test report No.: Test instruments used: EN :2009 Immunity to conducted disturbances, induced by radiofrequency fields Denomination Manufacturer Type Serial No. Next calibration Applied Signal generator Rhode & Schwarz SMY / Amplifier Amplifier Research 25A250A RF millivoltmeter Rhode & Schwarz URV / CDN MEB AF CDN MEB M CDN MEB M Note(s): --- Photo(s) on the measuring arrangement:
31 EMC Page 31 / 33 Test report No.: EN :2004 Immunity against voltage dips, short interruptions and voltage variations Date of measurement: Ambient conditions: Ambient temperature: 21 C Relative humidity: 47 % Air pressure 1013 hpa Test setup: Laboratory test Post-installation test Evaluation based on the test results: Passed Failed Note(s): The measurement was performed on the place of applicant.
32 EMC Page 32 / 33 Test report No.: Operating conditions: EN :2004 Immunity against voltage dips, short interruptions and voltage variations Description of operating conditions applied for testing of the product (settings, load, program, etc.): The test sample was continuously operated. The test was carried out on the mains wires of the control electronics only. Performance criteria A Normal operation within the prescribed limits. B C After a temporary degradation or failure of function the normal operation is restored automatically. After a temporary degradation or failure of function the normal operation is restored by the operator's action. Immunity to voltage dips Test voltage (U T ): 230V 230V 230V 230V Method of supply: Voltage dip ( U): 100% 60% 30% 100% Reduced voltage: 0V 0V 161V 0V Duration of voltage dip: 10ms 20ms 500ms 5s Number of voltage dip: Performance criterion: B B C C Operation of the EUT during the test: A No change was observed A No change was observed A No change was observed B Automatically restarted Note(s): Test level and performance criterion are specified in EN :2007 standard.
33 EMC Page 33 / 33 Test report No.: Test instruments used: EN :2004 Immunity against voltage dips, short interruptions and voltage variations Denomination Manufacturer Type Serial No. Next calibration Applied Combined generator EM Test UCS Power supply Kikusui PCR 2000L A Power supply Kikusui PCR 2000L A Power supply Kikusui PCR 2000L A Multimeter Hioki Multimeter Norma MP 14 X324871C Note(s): --- Photo(s) on the measuring arrangement:
EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A
Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2
More informationReport for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B
Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed
More informationEN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass
Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz
More informationEMC test report AU01+E04
Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of
More informationReport for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027
Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary
More informationEMC standards. Presented by: Karim Loukil & Kaïs Siala
Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards
More informationHarmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass
Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,
More informationDiscontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz
Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA
Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationDiscontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz
Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25
15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE
More informationr(oilgln TEST REPORT 'AGREB 6 %P\l Br EMC10001 sasa Gros, B.s"{h-$ INSTITUTE EMC and Safetv Laboratorv
r(oilgln Electrlcal Engin.erlng INSTITUTE Br. 21583EMC10001 TEST REPORT EMC and Safetv Laboratorv Page/Pages:1 /40 Test item: CT Powered Time Over-current relay Model: SIGMA XS Manufacturer: KONCAR - ELEKTRIcNI
More informationOverview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University
Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27
15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
More informationCTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CNB3150602-00399-E 2/F., South Tower, Huoju Building, No.181, Canghai Road,
More informationTEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed
17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:
More informationBy order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China
4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR
More informationEMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009
Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203
More informationELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co.,
More informationTEST REPORT. Power Spout PLT V. tested to the specification
EMC Technologies (NZ) Ltd PO Box 68-307 Newton, Auckland 1145 New Zealand Phone 09 360 0862 Fax 09 360 0861 E-Mail Address: aucklab@ihug.co.nz Web Site: www.emctech.com.au TEST REPORT Power Spout PLT 100
More informationEMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan
Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE
More information2620 Modular Measurement and Control System
European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic
More informationTEST REPORT EMC. 1, Mikhaila Kotzubinskogo St., Kyiv, Ukraine, IECCISPR14_1&2_IEC61000_3_2&3B
Test Report issued under the responsibility of: TEST REPORT EMC Requirements for household appliances, electric tools and similar apparatus Report Reference No.... : 28220034 001 Date of issue... : 2013-10-17
More informationTest Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013
More informationEMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi
EMC TEST REPORT For Shenzhen Ruideou Keji Youxian Gongsi Product Name: Trademark: Milligram Scale WAOAW Model Number: W-01-50 Prepared For : Address: Prepared By : Address: Shenzhen Ruideou Keji Youxian
More informationEMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.
DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model
More informationA) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23
D I R E C T O R Y A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 B) Test data: Immunity against Electrostatic discharge
More informationEMC Test report for LED Panel Light Models , , , , ,
4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,
More informationCE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10
CE/EMC TEST REPORT For HK QNOVATOR TECHNOLOGY CO.,LIMITED Product Name: Vacuum Tube Amplifier Trademark: Model Number: Prepared For: Address: Gemtune GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05,
More informationEMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.
Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial
More informationEMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS
EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by
More informationSUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE
EMC TEST REPORT For SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD Product Name: Pure sine wave power inverter Trademark: Model : Prepared For : Address: Prepared By : Address: ML-1000W ML-300W---ML-8000W.
More informationEN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd
Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE
More informationBS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE
Page 1 of 18 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationBy order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan
4322705.50 EMC Test report for Plug-in adaptor Models PM1W-IT, PM1WU2-IT, PM1W-GR, PM1W-SP, PM1W-RS, PM1WB-RS, PM1WU2-GR, PM1WU2-SP, PM1WU2-RS, PM1WBU2-RS, PM1W-UK, PM1WU2-UK, PM1W-FR, PM1WU2-FR Guangzhou,
More informationShenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20
Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB
More informationEMC VERIFICATION SUMMARY Report No.: SZHH
EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA
More informationEMC TEST REPORT. Report No.: CE10-LIE040101E
EMC TEST REPORT Report No.: CE10-LIE040101E Product: LED TUBE Model No.: T10, T8, T5 Applicant: Shenzhen Saiju Electronic Co., Ltd. Address: 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao an, Shenzhen,
More informationLS200 TEST DATA IEC61000 SERIES
TEST DATA IEC61000 SERIES DWG. No. PA607-58-01 APPD CHK DWG TDK-Lambda INDEX LS200 PAGE 1. Electrostatic Discharge Immunity Test (IEC61000-4-2) R-1 2. Radiated Radio-Frequency Electromagnetic Field Immunity
More informationEMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08. Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC EMC Laboratory
L.E.M. S.r.l. Notified Body (ID 2034) EMC TEST REPORT Model: 053-EMC-TR_ING, rev. 12 del 15/05/08 Laboratory identification: L.E.M. S.r.l. UNI CEI EN ISO/IEC 17025 EMC Laboratory recognized by Ministry
More informationAPPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:
APPLICATION FOR EMC DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co., Ltd led flood light Trade Name: Model: QH-TGC-400W, QH-TGC-300W, QH-TGC-500W, QH-TGC-800W, QH-TGC-1000W Prepared For : Shenzhen
More informationEMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS
EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS Prepared For : Prepared By : Changzhou Airwheel Technology Co.,Ltd. Fl.5, East of No. 10 Building, high-tech
More informationPage: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003
Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003
More informationBUREAU VERITAS. itaste svd
BUREAU VERITAS TEST REPORT No.: (5213)095-0238 TEST REPORT To: INNOKIN TECHNOLOGY CO., LTD I Fax: I -- Attn: -- I -- I Address: Buildinq 6, XinXinTian Industrial Park, XinSha Road, Sha.Jinq street, ShenZhen,
More information1 SUMMARY OF STANDARDS AND RESULTS
1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard
More informationReport on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016
Report on the EMC Testing For Exception EMS Ltd On RBK-ILS Processor Report No. TRA-028046-36-00A 29 th April 2016 RF657 7.0 Report Number: Copy Number: TRA-028046-36-00A PDF REPORT ON THE EMC TESTING
More informationEMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45
REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business
More informationPT. SARANA KARYA SOLUSINDO.
Shenzhen BST Technology Co., Ltd. PT. SARANA KARYA SOLUSINDO. EMC REPORT Prepared For : PT. SARANA KARYA SOLUSINDO. Puri Surya Jaya J1. 29 Cluster Vancouver, Gedangan, Sidoarjo, Jawa Timur - Indonesia
More informationTABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46
TABLE OF CONTENTS 1. GENERAL INFORMATION...5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...5 1.2 OBJECTIVE...5 1.3 RELATED SUBMITTAL(S)/GRANT(S)...5 1.4 TEST METHODOLOGY...5 1.5 TEST FACILITY...5
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass
Seite 2 von 35 Page 2 of 35 TEST SUMMARY 5.1.1 HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Pass 5.1.3 CONDUCTED DISTURBANCE AT THE MAINS PORTS RESULT:
More informationReport No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for
Report No.: 9A042401C2 Page 1 of 36 EN 50121-4: 2006 Product: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client Trade Name: MOXA Model Number: AWK-5222 Prepared for MOXA Inc. Fl.4, No.135, Lane 235,
More informationConformity Report Electromagnetic Compatibility according to EMC Directive 2004/108/EEC. Equipment Under Test (EUT)
Worldwide Certification and Test System Tel.: (719) 522-1402 (719) 522-1086 www.intertest.net Conformity Report Electromagnetic Compatibility according to EMC Directive 2004/108/EEC Test Report No.: R11CS136E
More informationTest Report. Ningbo Goldmore Industrial Co.,Ltd.
Test Report Applicant: Ningbo Goldmore Industrial Co.,Ltd. Product Name: Brand Name: Model No.: LED CAMPING LANTERN with FAN N/A XJH-8098 Date of Receipt : Sep. 23, 2014 Date of Test: Sep. 25, 2014 Date
More informationEMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG
EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG SWITCHING POWER SUPPLY Model No. HSM-50-12~48 HSM-15-5~24, HSM-35-12~48. : DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG : No.3 Tengfei Road,
More informationTABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10
TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-10 3.2 Radiated Emission Tests 11-13 3.3 Radiated Electromagnetic disturbance Test 14-18
More informationCE/EMC TEST REPORT. For. Noron Ltd.
Product Name: Trademark: Model Number: Prepared For: Address: Prepared By: CE/EMC TEST REPORT NVR Noron, Videokernel, Huatu For Noron Ltd. HTNR-5004L-P4 HTNR-5004-P4, HTNR-5004-P4-I, HTNR-5008-P8, HTNR-5008-P8-I,
More informationCTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3150428-00472-E-R1 2/F., South Tower, Huoju Building, No.181, Canghai Road,
More informationTEST REPORT. Information technology equipment
TEST REPORT Information technology equipment Report Reference No.... 272750TRFEMC Tested by G. Bazzi (project handler)... (name, function and signature)... Approved by G. Curioni (name, function and signature)...
More informationLAB engineer Milivoje Miletić
EMC TEST REPORT # 496 Date of the report 06.08.2018. Date of testing 19. 26.07.2018. Job # 496 Customer Grigorii Grabovoi PR KONSALTING TECHNOLOGIES OF ETERNAL DEVELOPMENT, Kneza Mihaila 21A lok 113 TC
More informationCommunication Certification Laboratory
Communication Certification Laboratory November 29, 2006 Mr. Samuel Smith Adept Systems Inc. 2966 Fort Hill road Eagle Mountain, UT 84005 Dear Sam: Communication Certification Laboratory has completed
More informationTEST REPORT. EN / EN Information technology equipment Radio disturbance / Immunity characteristics Limits and methods of measurement
TEST REPORT EN 55032 / EN 55024 Information technology equipment Radio disturbance / Immunity characteristics Limits and methods of measurement Report Reference No....354297-2TRFEMC Tested by (name, function
More informationBS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C
Page 1 of 23 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Variant Model Name: Applicant: CAMERA HOUSING SAMSUNG TECHWIN CO., LTD. SCX-FH200B SHB-4200 SAMSUNG TECHWIN
More informationContents. Report No.: EMC-CE-2114 Page: 2 of 39
Page: 2 of 39 Contents 1. Applicant information... 3 2. Laboratory information... 4 3. Test system configuration... 5 3.1 Operation environment... 5 3.2 Measurement Uncertainty... 6 4. Description of E.U.T...
More informationCONFORMANCE TEST REPORT FOR EN /-6
CONFORMANCE TEST REPORT FOR EN 301489-1/-6 Client: Product: Model: Manufacturer/supplier: Aztech Systems Limited DECT Phone H315-S1 (FP) Aztech Systems Limited Date test item received: 2006/05/09 Date
More informationTABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12
TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-12 3.2 Radiated Emission Tests 13-15 3.3 Radiated Electromagnetic disturbance Test 16-20
More informationEMC TEST REPORT. Oina VV AB. Dispenser system. Accurate speedcontrol BLDC/ Report no: Approved by Tobias Gustavsson
EMC TEST REPORT Oina VV AB Dispenser system Accurate speedcontrol BLDC/ Report no: 09007 Prepared by Ulf Heiding Approved by Tobias Gustavsson Date 2009-01-23 This report may not be reproduced other than
More informationEMC T E S T R E P O R T
Registration No. DAT-P-207/05 EMC T E S T R E P O R T Test Report No. : E33047-00-00NL 04. November 2008 Date of issue Type / Model Name : HCP Best Product Description : Cash register with integrated GPRS
More information9. Electrostatic Discharge Immunity Test (ESD)
9. Electrostatic Discharge Immunity Test (ESD) Test Mode: Mode 1 Final Test Result : PASS Pass Performance Criteria : A Required Performance Criteria: B Basic Standard : IEC 61000-4-2:Edition 1.2:2001-04
More informationEMC Test report for Plug-in adaptor Models PM1Wab-ccc
4345892.50V1.0 EMC Test report for Plug-in adaptor Models PM1Wab-ccc (a=nil or B, indicate color of product; b=nil or U2, indicate USB output provided; c=a to Z, or nil, indicate different outlet style)
More informationEMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
More informationTEST REPORT. Table of Contents
Page:2 of 35 Table of Contents 1. DOCUMENT POLICY AND TEST STATEMENT... 4 1.1 DOCUMENT POLICY...4 1.2 TEST STATEMENT...4 1.3 EUT MODIFICATION...4 2. DESCRIPTION OF EUT AND TEST MODE... 5 2.1 GENERAL DESCRIPTION
More informationShenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter
EMC TEST REPORT For Shenzhen Huanxi Technology Co., Ltd Product Name: Smart Self-balancing Scooter Trademark: Model : Prepared For : Address: Prepared By : Address: N/A X1S6.5 X1L6.5, X1S 8, X1L8. Shenzhen
More informationEMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD
Page 1 of 45 Report No. R011607240E EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD INVERTER CHARGER Model No.: PV35-4K DC24V MPK, PV35-4K DC48V MPK, PV35-5K DC48V MPK, PV35-6K DC48V MPK Prepared
More informationTEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54
Equipment Under Test Brand Name Model No. Added Model(s) Applicant Address of Applicant Page : 1 of 54 TEST REPORT : AC Servo Motor : Kingservo : AC 400W servo motor : N/A : Ho Fo Automation CO., LTD :
More informationEMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758
Page 1 of 20 Report No. R011604553E EMC TEST REPORT for DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., LTD. Electronic calculator Model No.: KF15758 Prepared for Address Prepared by Address : DONGGUAN EVER
More informationTest Report. E4S-Box V1.0
TTI-P-G 100/96-30 EMC Laboratory Test Report No. 05 / 5040-1-1 E4S-Box V1.0 S/N: 7 The results refer only to the tested equipment. Without written permission of the test laboratory it is not allowed to
More informationTest Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49
Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance
More informationETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.
ETSI EN 301 489-1 V2.2.0 (2017-03) ETSI EN 301 489-3 V2.1.1 (2017-03) TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-10P Report Type: Amended Report
More informationGuangdong East Power Co., Ltd. Uninterruptible Power Systems
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012
More informationKutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger
Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 ISERT (Pty) Ltd. Reg: 2017/186396/07 Tel: + 27 (0)12 548 0940 E-Mail: info@isert.co.za 129 Khai-Apple street Montana Pretoria 0186 EMC TEST
More informationPage: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6
Page: 1 of 41 EMC TEST REPORT Reference No. Applicant : WT05060416 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Multi-socket with surge protection Standards Model No. : SPG3-B-10,
More informationTest Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller
Test Report Applicant: Product Name: Brand Name: Model No.: Apricus Solar Co., Ltd. Multi-Function Differential Controller Apricus MFC-1 Date of Receipt : Jan. 04, 2012 Date of Test: Jan. 04, 2012 Date
More informationEN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017
EN 301 489-17 v3.1.1 TEST REPORT FOR Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 Prepared for Texas Instrument 2900 Semiconductor Drive Santa
More informationTest Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,
Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, EN 301 489-1 V1.8.1 Electromagnetic compatibility and
More informationTest Laboratory No Accredited by CAI for Electromagnetic Compatibility, Electrical Safety and Electrical Cable Tests
ABEGU, a.s. ZKUSEBNA Test Laboratory No. 1184 Accredited by CAI for Electromagnetic Compatibility, Electrical Safety and Electrical Cable Tests Test Report No. P/13/01/48-2 : Test standards: AFR 31 - Smart
More informationA Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.
A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity
More informationEMC TEST REPORT. according to
EMC TEST REPORT according to European Standard EN 55022:2006/A1:2007 Class B, EN 61000-3-2:2006, EN 61000-3-3:1995/A1:2001/A2:2006, EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:Edition 1.2:2001-04, IEC
More informationPage: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK
Page: 1 of 46 Reference No. Applicant : WT05060414 EMC TEST REPORT : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Advanced surge protection Model No. : SISF, SISF-2, SISFN-BLACK,
More informationEMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009
CE TEST REPORT Report Number : ETLE080219.157.1 Report issue date: August 21, 2009 Model / Serial No. : NSD-S360 / NONE Multiple Model Name : NSD-S300, NSD-S230, NSD-S680, NSD-H350, NSD-S330, NSD-S370,
More informationTest Report GUANGDONG EAST POWER CO., LTD
Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA906IIRTS, EA906IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014
More informationEMC TEST REPORT For Prokits Industries Co., Ltd.
Page 1 of 34 EMC TEST REPORT For Prokits Industries Co., Ltd. Temperature-Controlled Soldering Station Model No.:SS-206/207 Series Test Report Number : ESTSZ110701228E EST COMPLIANCE LABORATORY LIMITED
More informationCE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E
CE-EMC Test Report Applicant: Product Description: Tested Model: Test Standards: Report No.: United GULF GATE Trd. Co. XonTel MS EN 55032:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024 :2010+A1 :2015
More informationEMC & Electrical Test Laboratory EMC LAB EQUIPMENT RESOURCES PER OEM TEST METHOD EQUIPMENT DCX FORD GM
EMC & Electrical Laboratory Page 1 of 5 Purpose: To maintain a list of equipment resources required per OEM test method. Responsibility: EMC technical manager, EMC lab technicians Method: EQUIPMENT DCX
More informationElectromagnetic Compatibility
Electromagnetic Compatibility Introduction to EMC International Standards Measurement Setups Emissions Applications for Switch-Mode Power Supplies Filters 1 What is EMC? A system is electromagnetic compatible
More informationBy order of American Power Conversion Holdings Inc. at New Taipei, Taiwan. Author : Harry Deng Reviewed : Tim Yan Pages : 53 pages Annex : NIL
4338754.50 EMC Test report for Multiple Protable Socket-outlets with SPD Models PM5-GR, PM5-RS, PM5-SP, PM5-UK, PM5U-GR, PM5U-RS, PM5U-UK, PM5U-SP, PM5V-GR, PM5V-RS, PM5V-SP, PM5V-UK, PM5T-GR, PM5T-RS,
More informationEMC Seminar Series All about EMC Testing and Measurement Seminar 1
EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Test of: Maestro Wireless Solutions Limited, Maestro 100evo To: EN 301 489-1 V1.8.1 referencing EN 301 489-7 V1.3.1 Test Report Serial No: RFI-EMC-RP78797JD02A This test report
More information