TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10
|
|
- Wendy West
- 5 years ago
- Views:
Transcription
1
2
3 TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test Conducted Emission Tests Radiated Emission Tests Radiated Electromagnetic disturbance Test Power Frequency Harmonics and Flicker Emission Tests Electrostatic Discharge Immunity Test Radiated, radio-frequency, electromagnetic field immunity test Electrical fast transient/burst immunity test Surge immunity test Conducted immunity test Voltage Dips and Short interruptions immunity test EUT Photographs Page Number : Page 2 of 40
4 1. General Description of EUT 1.1 Applicant Company Name : SoluM Co., Ltd. Address : Contact Person : Ki-Dong, Lee 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, Republic of Korea E mail : kdlee007@solu-m.com Phone / FAX : TEL : FAX : Manufacturer Company Name : SoluM Co., Ltd. Address : Contact Person : Ki-Dong, Lee 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, Republic of Korea E mail : kdlee007@solu-m.com Phone / FAX : TEL : FAX : Basic Description of EUT Trade Name : Product Name : LED CONVERTER Model Name : SLW320N571N1A ADD Model : SLW230N421N1A, SLW320N571N1E Serial Number : Prototype Test Voltage : AC 230 V, 50 Hz Rating : Input: AC ( ) V, (50/60) Hz, MAX 0.45 A, 35 W Output: DC (23-50) V, 0.57 A, 28 W Page Number : Page 3 of 40
5 2. General Information of Test 2.1 Test Facility This test was carried out by BWS TECH Inc. Test Site Location : 23, Gokhyeon-ro 480 Beon-gil, Mohyeon-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do , Korea TEL : FAX : Standard for Methods of Measurement Basic Standard Description Test Result EN 55015:2013 EN 61547:2009 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Equipment for general lighting purposes EMC immunity requirements Pass Pass Fail Fail EN :2014 Mains harmonics equipment up to 16A. Pass Fail EN :2013 Voltage fluctuations equipment up to 16A. Pass Fail EN :2009 EN :2006+A2:2010 EN :2012 Testing and measurement techniques. Electrostatic discharge immunity test. Testing and measurement techniques. Radiated Immunity. Testing and measurement techniques. Electrical fast transient/burst immunity test. EN :2014 Testing and measurement techniques. Surge immunity test. Pass Fail EN :2014 Testing and measurement techniques. Immunity to conducted disturbances induced by Pass Fail radio frequency fields. EN :2010 Testing and measurement techniques. Power frequency magnetic field Immunity Test. N/A #Note 1 EN :2004 Testing and measurement techniques. Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests. Pass Fail #Note 1. This test was excluded, because EUT was not containing any devices susceptible to magnetic fields. 2.3 Description of EUT Modification - N/A 2.4 Variations covered by this report - N/A 2.5 Additional information related to Testing Test results apply only to the particular sample tested and functionality described in this test report. This report may be reproduced in full. Partial reproduction may only be made with the written permission of the BWS Tech Inc. Pass Pass Pass Fail Fail Fail Page Number : Page 4 of 40
6 2.6 Model Difference Basic Model is SLW320N571N1A - Variant Models are SLW230N421N1A, SLW320N571N1E. Additional models derived by the buyer s request. 2.7 Test Conditions EUT Operating Mode EUT was tested according to the following operation modes provided by the specifications given by the manufacturer, and reported the worst emissions. Operation Modes Worst Case Mode Normal Operation Mode Performance Criteria A) Performance Criterion A During the test, no change of the luminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended. B) Performance Criterion B During the test, the luminous intensity may change to any value. After the test, the luminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given. C) Performance Criterion C During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control Page Number : Page 5 of 40
7 Test System layout on EUT and peripherals Interface cable Power cable JIG LED EUT 2.8 Description of Test System (EMI and EMS) Type of Peripheral Equipment Used: Description Model Name Serial No. Manufacturer EUT SLW320N571N1A Prototype SoluM Co., Ltd. LED N/A N/A N/A JIG N/A N/A N/A Type of Cables Used: Device from I/O Port Device to I/O Port Length(m) Type of Shield EUT JIG AC IN Power Socket Unshielded DC OUT LED DC IN 0.3 Unshielded - EUT - Direct - - LED - Direct - Page Number : Page 6 of 40
8 3.1 Conducted Emission Tests Conducted Emissions were measured from 9 khz to 150 khz with a bandwidth of 200 Hz, 150 khz to 30 MHz with a bandwidth of 9 khz on the 230 V AC power and return leads of the EUT according to the methods defined in European Standard EN 55015:2013 Clause 8. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions Test Condition Test Standard Frequency Range of Test : 9 khz to 30 MHz Test Standard : EN 55015:2013 Test Date : 13 January 2017 Temperature/Humidity : 16 C / 37 % R.H. Item Main Terminal Frequency Range Limit db(uv) (MHz) Quasi-Peak Average-Peak to to to Item Control Terminal Frequency Range Limit db(uv) (MHz) Quasi-Peak Average-Peak to to Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use EMI Test Receiver ESPI ROHDE & SCHWARZ LISN LN2-16N EMCIS LN Page Number : Page 7 of 40
9 3.1.4 Test Result of Conducted Emission EUT : SLW320N571N1A Input Voltage : AC 230 V, 50 Hz Test Mode : L1 Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 8 of 40
10 EUT : SLW320N571N1A Input Voltage : AC 230 V, 50 Hz Test Mode : N Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Notes 1. Margin = Limit - Emission Level 2. All modes of operation were investigated and the worst-case emissions are reported. See the plots in next pages. 3. Measurement uncertainty estimated at 3.72 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 9 of 40
11 3.1.5 Photographs of Conducted Emission Test Configuration [Conducted Emission Test-Main Terminals] Page Number : Page 10 of 40
12 3.2 Radiated Emission Tests Radiated emissions form 30 MHz to 300 MHz were measured with a bandwidth of 120 khz according to the methods defines in EN 55015:2013. The EUT was placed on a nonmetallic stand in the 10 m chamber, 0.8 meter above the ground plane, as shown in section The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions Test Condition Frequency Range of Test : 30 MHz to 300 MHz Test Standard : EN 55015:2013 Test Date : 13 January 2017 Temperature/Humidity : 19 C / 25 % R.H Test Standard Frequency Range (MHz) Limit (dbuv) Quasi-Peak 30 ~ ~ Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Bilog Antenna VULB 9160 SCHWARZBECK EMI Test Receiver ESR ROHDE & SCHWARZ RF AMPLFIER MPA RF Bay Antenna Mast ( 4 m) AM 4.0 MATURO Positioner Controller CO2000 MATURO AM4.0/225/ NCU/459/ N/A N/A Page Number : Page 11 of 40
13 3.2.4 Test Result of Radiated Emission EUT : SLW320N571N1A Test distance : 10 m Radiated Emission Test Results : PASS Test data sheets follow. Radiated Emission Test Data Notes 1. * H : Horizontal polarization, ** V : Vertical polarization 2. Margin value = Emission Level Limit (Quasi-Peak) 3. Corr. = Correction factor (Antenna factor + Cable loss AMP gain) 4. Measurement uncertainty estimated at 5.49 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 12 of 40
14 3.2.5 Photographs of Radiated Emission Test Configuration [Radiated Emission Test] Page Number : Page 13 of 40
15 3.3 Radiated Electromagnetic disturbance Test Radiated emissions form 9 khz to 30 MHz were measured with a bandwidth of 200 Hz, 9 khz according to the methods defines in EN 55015:2013. The EUT was placed on a nonmetallic stand as shown in section Test Condition Frequency Range of Test : 9 khz to 30 MHz Test Standard : EN 55015:2013 Test Date : 13 January 2017 Loop Antenna Size : 2 m Temperature/Humidity : 16 C / 36 % R.H Test Standard Frequency Range (MHz) Quasi-Peak Limit (dbuv) Average-Peak N/A to 58 N/A to 26 N/A N/A Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Loop Antenna HXYZ 9170 SCHWARZBECK HXYZ N/A EMI Test Receiver ESPI ROHDE & SCHWARZ Page Number : Page 14 of 40
16 3.3.4 Test Result of Radiated Emission EUT : SLW320N571N1A Loop Antenna Size : 2 m Test mode : X-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 15 of 40
17 EUT : SLW320N571N1A Loop Antenna Size : 2 m Test mode : Y-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 16 of 40
18 EUT : SLW320N571N1A Loop Antenna Size : 2 m Test mode : Z-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Notes 1. Margin value = Limit - Emission Level 2. All other emissions not reported were more than 25 db below the permitted limit. 3. Measurement uncertainty estimated at 2.99 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 17 of 40
19 3.3.5 Photographs of Radiated Electromagnetic disturbance Test. [Radiated Electromagnetic disturbance Test] Page Number : Page 18 of 40
20 3.4 Power Frequency Harmonics and Flicker Emission Tests Test Procedure Power Frequency Harmonics Tests : The measured values of the harmonics components of the input current, including line current and neutral current, shall be compared with the limits given in Clause 7 of EN :2014 Flicker Emission Tests : The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of the reference impedance shall be adequate to ensure that the overall accuracy of 8 % is achieved during the whole assessment procedure Test Condition EUT : SLW320N571N1A Test Standard : EN :2014 EN :2013 Test Date : 13 January 2017 Device Class : C Temperature/Humidity : 21 C / 37 % R.H Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compliance Test System PACS-1 California Instruments N/A AC Power Source 5001IX California Instruments Test Result of Power Frequency Harmonics and Flicker Emission Tests Power Frequency Harmonics : PASS Flicker Emission Tests : PASS Page Number : Page 19 of 40
21 V o l t a g e ( V o l t s ) Harmonics Class-C (Run time) EUT: SLW320N571N1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass C u r r e n t ( A m p s ) Current & voltage waveforms C u r r e n t R M S ( A m p s ) Harmonics and Class C limit line Source qualification: Normal European Limits H a r m o n i c # Test result: Pass Worst harmonics H % of 100% limit, H % of 150% limit. Page Number : Page 20 of 40
22 Current Test Result Summary (Run time) EUT: SLW320N571N1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass Source qualification: Normal THC(A): 0.01 I-THD(%): 7.63 POHC(A): POHC Limit(A): Highest parameter values during test: V_RMS (Volts): Frequency(Hz): I_Peak (Amps): I_RMS (Amps): I_Fund (Amps): Crest Factor: Power (Watts): 30.8 Power Factor: Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum harmonics/limit ratio. Page Number : Page 21 of 40
23 Voltage Source Verification Data (Run time) EUT: SLW320N571N1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass Source qualification: Normal Highest parameter values during test: Voltage (Vrms): Frequency(Hz): I_Peak (Amps): I_RMS (Amps): I_Fund (Amps): Crest Factor: Power (Watts): 30.8 Power Factor: Harm# Harmonics V-rms Limit V-rms % of Limit Status OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK Page Number : Page 22 of 40
24 1 3 : 5 6 : 3 4 Flicker Test Summary per EN/IEC (Run time) EUT: SLW320N571N1A Tested by: BWS TECH Inc. Test category: All parameters (European limits) Test Margin: 100 Test duration (min): 10 Customer: SoluM Co., Ltd. Test Result: Pass Status: Test Completed Psti and limit line European Limits P s t Parameter values recorded during the test: Vrms at the end of test (Volt): Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): Test limit: Pass Page Number : Page 23 of 40
25 3.4.5 Photographs of Power Frequency Harmonics and Flicker Emission Tests Configuration. [Power Frequency Harmonics and Flicker Emission Tests- Harmonics] [Power Frequency Harmonics and Flicker Emission Tests- Flicker] Page Number : Page 24 of 40
26 3.5 Electrostatic Discharge Immunity Test In order to minimize the impact of environmental parameters on test results, the tests shall be carried out in climatic and electromagnetic reference conditions as specified in EN 61547:2009. The test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. The testing shall be performed by direct and indirect application of discharges to the EUT according to a test plan Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN :2009 Test Date : 13 January 2017 Test Voltage : Contact 4 kv, Air (2,4,8) kv Performance criterion : B Temperature/Humidity/Pressure : 19 C / 34 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use ESD Simulator EDS30V 3CTEST ES Test Result of Electrostatic Discharge Immunity Test Electrostatic Discharge Immunity Test : PASS The equipment meets the requirements. Page Number : Page 25 of 40
27 Test data sheet follows. Test Point Discharge Type CD=Contact AD=Air Test Voltage(kV) Tested No Observation Result VCP CD 4 kv Each 10 times Normal PASS (A) HCP CD 4 kv Each 10 times Normal PASS (A) EUT Case AD (2,4,8) kv Each 10 times Normal PASS (A) [Test Point] AD CD Front Rear Left Right Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 2. The direct contact discharge test was excluded because there is no applicable surface on EUT. Page Number : Page 26 of 40
28 3.5.4 Photographs of Electrostatic Discharge Immunity Test Configuration [Electrostatic Discharge Immunity Test] Page Number : Page 27 of 40
29 3.6 Radiated, radio-frequency, electromagnetic field immunity test Tests were conducted in accordance with EN 61547:2009 over the frequency range of 80 MHz to MHz. The transmitting antenna was located 3 meters from the EUT at a height of 1 meter above the floor. Front, sides and back of the EUT were exposed to a uniform field of 3 V/m using both horizontal and vertical antenna polarizations Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN :2006+A2:2010 Test Date : 13 January 2017 Test field strength (V/m) : 3 V/m Performance criterion : A Temperature/Humidity/Pressure : 20 C / 32 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Signal Generator SME06 ROHDE & SCHWARZ / RF Power Amplifier ITA0300KL-500 Infinitech N/A RF Power Amplifier ITA0750KL-500 Infinitech N/A Log periodic Antenna K9128 Airlinklab N/A Test Result of Radiated, radio-frequency, electromagnetic field immunity test Electromagnetic field immunity test : PASS The equipment meets the requirements. Page Number : Page 28 of 40
30 Test data sheet follows. Frequency Range (MHz) Position (Angle) Antenna Polarity Field Strength (V/m) Modulation Result Front Vertical 3 80 % AM (1 khz) PASS (A) Rear Vertical 3 80 % AM (1 khz) PASS (A) Right Vertical 3 80 % AM (1 khz) PASS (A) Left Vertical 3 80 % AM (1 khz) PASS (A) Front Horizontal 3 80 % AM (1 khz) PASS (A) Rear Horizontal 3 80 % AM (1 khz) PASS (A) Right Horizontal 3 80 % AM (1 khz) PASS (A) Left Horizontal 3 80 % AM (1 khz) PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode Photographs of Radiated, radio-frequency, electromagnetic field immunity test Configuration [Radiated, radio-frequency, electromagnetic field immunity test] Page Number : Page 29 of 40
31 3.7 Electrical fast transient/burst immunity test Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1 kv to AC power lines Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN :2012 Test Date : 13 January 2017 Test Voltage : 1 kv (power lines) Performance criterion : B Temperature/Humidity/Pressure : 19 C / 34 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES Test Result of Electrical fast transient/burst immunity test Electrical fast transient/burst immunity test : PASS The equipment meets the requirements. Page Number : Page 30 of 40
32 Test data sheet follows. Line Voltage Coupling Inject Time (sec) Result L1-N 1 kv Direct 120 PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 2. PE port test was excluded because there was no PE port on the power for the test Photographs of Electrical fast transient/burst immunity test Configuration [Electrical fast transient/burst immunity test] Page Number : Page 31 of 40
33 3.8 Surge immunity test Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1.0 kv to AC Line to Line and 2.0 kv to Line to Ground Test Condition Test Voltage Test levels EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN :2014 EUT Input : AC 230 V, 50 Hz Test Date : 13 January 2017 Test Voltage : 1.0 kv (Line to Line), 2.0 kv (Line to Ground) Performance criterion : B Temperature/Humidity/Pressure : 19 C / 34 % R.H. / kpa Characteristics Self-ballasted lamps and semi-luminaires Test levels Device Luminaries and independent auxiliaries Input Power 25 W > 25 W Wave-shape data 1.2/50 µs 1.2/50 µs 1.2/50 µs Line to Line 0.5 kv 0.5 kv 1.0 kv Line to Ground 1.0 kv 1.0 kv 2.0 kv Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES Test Result of Surge immunity test Surge immunity test : PASS The equipment meets the requirements. Page Number : Page 32 of 40
34 Test data sheet follows. Line Voltage (kv) Coupling Phase(Degree) Inject (count - min) Result L1-N (0.5, 1.0) kv 18 F 90, times - 5 min PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 2. PE port test was excluded because there was no PE port on the power for the test. 3. The input power of EUT is over 25 W Photographs of Surge immunity test Configuration [Surge immunity test] Page Number : Page 33 of 40
35 3.9 Conducted immunity test Tests were conducted in accordance with EN 61547:2009. Over the frequency range of 150 khz to 80 MHz. Tests were performed at 3 V on power line Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method EN :2014 Test Date : 13 January 2017 Test Voltage : 3 V Performance criterion : A Temperature/Humidity/Pressure : 16 C / 39 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use RF Power Amplifier 5085 OPHIR RF Signal Generator SMT03 ROHDE & SCHWARZ / Attenuator 200W6dB N/A N/A N/A CDN FCC-801-M2-32A FCC Test Result of Conducted immunity test Conducted immunity test : PASS The equipment meets the requirements. Page Number : Page 34 of 40
36 Test data sheet follows. Frequency Test port (MHz) Coupling Dwell time Modulation Step Size Result Power CDN (M2) 1 s 80 % AM (1 khz) 1.0 % PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode Photographs of Conducted immunity test Configuration [Conducted immunity test] Page Number : Page 35 of 40
37 3.10 Voltage Dips and Short interruptions immunity test Voltage variations tests were conducted in accordance with EN 61547: Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN :2004 Test Date : 13 January 2017 Voltage Dip : 70 % (10 periods) Short interruptions : 0 % (0.5 periods) Performance criterion : 70 % (10 periods) - C, 0 % (0.5 periods) - B Temperature/Humidity/Pressure : 16 C / 34 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES Test Result of Voltage Dips and Short interruptions immunity test Voltage Dips and Short interruptions immunity test : PASS The equipment meets the requirements. Page Number : Page 36 of 40
38 Test data sheet follows. Test voltage level % Number of periods Angle ( ) Criteria Result , 180 C PASS (B) , 180 B PASS (A) Remarks 1. EUT was turned off at the test of Short interruptions in 70 % (10 periods), but it was fully functional after test. 2. Except for the test of Short interruptions in 70 % (10 periods), the primary functions as described below were fully functional during and after test Photographs of Voltage Dips and Short interruptions immunity test Configuration [Voltage Dips and Short interruptions immunity test] Page Number : Page 37 of 40
39 4. EUT PHOTOGRAPHS [Front of EUT] [Rear of EUT] Page Number : Page 38 of 40
40 [Front of PCB board] [Rear of PCB board] Page Number : Page 39 of 40
41 [Multi model label] Page Number : Page 40 of 40
TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12
TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-12 3.2 Radiated Emission Tests 13-15 3.3 Radiated Electromagnetic disturbance Test 16-20
More informationDescription of Version
Description of Version Edition No. Data of Revision Revision Summary Report No. 0 February 07, 2017 Original Report BWS-17-EC-0015 This Test Report shall not be reproduced, except in full, without the
More informationEMC TEST REPORT. According to
EMC TEST REPORT According to EN 55014-1: 2006 EN 55014-2: 1997+A1:2001 EN 61000-3-2: 2006 EN 61000-3-3: 1995+A1:2001+A2:2005 Test Report No. Equipment : BWS-08-EC-0001 : Air cleaner Model No : AIRVAX 33X2
More informationTABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11
Page : 2 / 38 TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 11 3.3 ELECTROSTATIC DISCHARGE IMMUNITY TEST 14
More informationEMC Test report for LED Panel Light Models , , , , ,
4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,
More informationEN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass
Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz
More informationEMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan
EMC TEST REPORT For MPP SOLAR INC Model Number: PIP 2424MS Prepare for Address : MPP Solar Inc : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan Prepare by Address : MPP Solar In : 4F, No. 50-1,
More informationEN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A
Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result
More informationHarmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass
Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,
More informationDiscontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz
Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationEMC VERIFICATION SUMMARY Report No.: SZHH
EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA
More informationEMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758
Page 1 of 20 Report No. R011604553E EMC TEST REPORT for DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., LTD. Electronic calculator Model No.: KF15758 Prepared for Address Prepared by Address : DONGGUAN EVER
More informationEMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS
EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by
More informationDiscontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz
Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationTABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10
TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 10 80, Jeil-ri, Yangji-myun, Cheoin-gu, Yongin-si, Gyeonggi-do,
More informationEMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008
Report No. : 08.08.16.0259.01 EMC TEST REPORT Applicant : Eastgate Global Holding LTD Address : DongchuanRoad,Baiyun 1Street,No.6 Office 502 Manufacturer : Eastgate Global Holding LTD Address : DongchuanRoad,Baiyun
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2
More informationEMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325
Page 1 of 39 EMC TEST REPORT For Shenzhen Scotle Technology Ltd CNC ROUTER Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325 Test Report Number : ESTBA151101209E SHENZHEN
More informationEMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009
CE TEST REPORT Report Number : ETLE080219.157.1 Report issue date: August 21, 2009 Model / Serial No. : NSD-S360 / NONE Multiple Model Name : NSD-S300, NSD-S230, NSD-S680, NSD-H350, NSD-S330, NSD-S370,
More informationEMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.
DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model
More informationEMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment
CE TEST REPORT for Audio / Video receivers and associated equipment Report Number : ETLE100104.03 Report Issue Date: January 15, 2010 Model / Serial No. : WSTA-VM300P / NONE Multiple Model Name : WSTA-VM320P,
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25
15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27
15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
More informationEMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
More informationEMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD
Page 1 of 45 Report No. R011607240E EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD INVERTER CHARGER Model No.: PV35-4K DC24V MPK, PV35-4K DC48V MPK, PV35-5K DC48V MPK, PV35-6K DC48V MPK Prepared
More informationCE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E
CE-EMC Test Report Applicant: Product Description: Tested Model: Test Standards: Report No.: United GULF GATE Trd. Co. XonTel MS EN 55032:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024 :2010+A1 :2015
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationEMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B
Page 1 of 27 Report No. R011412016E-1 EMC TEST REPORT for LEDELS LIGHTING CO., LTD LED module Model No. : LL-F12T4815X6B Prepared for : LEDELS LIGHTING CO., LTD Address : 5F, Block C, Mingjinhai Ind. Park,
More informationELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co.,
More informationShenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20
Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB
More informationPrepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by
EMC TEST REPORT For KST DIGITAL TECHNOLOGY LIMITED Coreless Servo Model No.: X12-508 Additional Model No.: DS215MG, DS315MG, DS213MG, DS313MG, DS12C, DS12T, X12-306 Prepared for Address : KST DIGITAL TECHNOLOGY
More informationEMC TEST REPORT. Report No.: CE10-LIE040101E
EMC TEST REPORT Report No.: CE10-LIE040101E Product: LED TUBE Model No.: T10, T8, T5 Applicant: Shenzhen Saiju Electronic Co., Ltd. Address: 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao an, Shenzhen,
More informationITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA
Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU
More informationTest Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49
Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance
More informationEMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8
EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 Prepared for Address : ShenZhen ZhangQing Electronic LTD :
More informationEMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45
REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business
More informationTest Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013
More informationTABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46
TABLE OF CONTENTS 1. GENERAL INFORMATION...5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...5 1.2 OBJECTIVE...5 1.3 RELATED SUBMITTAL(S)/GRANT(S)...5 1.4 TEST METHODOLOGY...5 1.5 TEST FACILITY...5
More informationAPPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:
APPLICATION FOR EMC DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co., Ltd led flood light Trade Name: Model: QH-TGC-400W, QH-TGC-300W, QH-TGC-500W, QH-TGC-800W, QH-TGC-1000W Prepared For : Shenzhen
More informationEN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments
EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16
More informationFor the following Product : LED CONVERTER Model Name : OLW160P351N1A
EU Declaration of Conformity EU Declaration of Conformity According to EMC Directive 2004/108/EC For the following Product : LED CONVERTER Model Name : OLW160P351N1A Manufactured at : SoluM Co., Ltd. Address
More informationEMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS
EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS Prepared For : Prepared By : Changzhou Airwheel Technology Co.,Ltd. Fl.5, East of No. 10 Building, high-tech
More information5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18
CONTENT TEST REPORT...1 CONTENT...2 1 TEST RESULTS SUMMARY...4 2 EMC RESULTS CONCLUSION...5 3 LABORATORY MEASUREMENTS...6 4 EMI TEST...7 4.1 EN 55014-1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST...7
More informationEMC test report AU01+E04
Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of
More informationEMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A
EMC Test Report Applicant: Address of Applicant: Trade Name: FATEK AUTOMATION CORP. 26FL, NO.29, SEC.2, JUNGJENG E. RD., DANSHUEI DIST., NEW TAIPEI CITY, TAIWAN, R.O.C. FATEK Equipment Under Test: Training
More informationEMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.
Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial
More informationPage: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6
Page: 1 of 41 EMC TEST REPORT Reference No. Applicant : WT05060416 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Multi-socket with surge protection Standards Model No. : SPG3-B-10,
More informationTest Report. Ningbo Goldmore Industrial Co.,Ltd.
Test Report Applicant: Ningbo Goldmore Industrial Co.,Ltd. Product Name: Brand Name: Model No.: LED CAMPING LANTERN with FAN N/A XJH-8098 Date of Receipt : Sep. 23, 2014 Date of Test: Sep. 25, 2014 Date
More informationTest Report GUANGDONG EAST POWER CO., LTD
Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA906IIRTS, EA906IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014
More informationTABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT
ELECTROMAGNETIC COMPLIANCE TEST REPORT For Electric nail art drill Model Name: HBS-021, HBS-278, HBS-288, HBS-530, HBS-540 Brand Name: Date of Issue: May 7, 2011 Prepared For Houbos Hardware & Electrical
More information1 SUMMARY OF STANDARDS AND RESULTS
1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard
More informationPage: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003
Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003
More informationEMC TEST REPORT For CE
EMC TEST REPORT For CE Test Report No. : CTK-2013-01069 Date of Issue : 2013-07-02 Kind of Product : FnIO S-Series Basic Model/Type No. : NA-9211, ST-5725, ST-5726 Variant Model/Type No. : NA-9212 Applicant
More informationEMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20
EMC TEST REPORT For Soma Medical (Sabah) Sdn Bhd (1248058-D) UVGI AIR STERILIZER Model No.: SM 20 Prepared For : Soma Medical (Sabah) Sdn Bhd (1248058-D) : Block E, Lot 28, 2nd floor, Signature Office,
More informationPT. SARANA KARYA SOLUSINDO.
Shenzhen BST Technology Co., Ltd. PT. SARANA KARYA SOLUSINDO. EMC REPORT Prepared For : PT. SARANA KARYA SOLUSINDO. Puri Surya Jaya J1. 29 Cluster Vancouver, Gedangan, Sidoarjo, Jawa Timur - Indonesia
More informationFor the following Product : LED CONVERTER Model Name : OLW250P701N1A
EU Declaration of Conformity EU Declaration of Conformity According to EMC Directive 2004/108/EC For the following Product : LED CONVERTER Model Name : OLW250P701N1A Manufactured at : SoluM Co., Ltd. Address
More informationEMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer
Test Standards: EMC Measurement and Test Report Product Description: Tested Model: Report No.: For 186 Veterans Dr. Northvale, NJ 07647 USA EN 55022:2010 EN 61000-3-2:2006+A1:2009+A2:2009 EN 61000-3-3:2008
More informationEMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK
EMC TEST REPORT For MUST POWER LIMITED Inverter Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK Prepared for : MUST POWER LIMITED Address : 4-5F Bldg11, Yusheng Industrial Park,No 467, Xixiang,
More informationPage: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK
Page: 1 of 46 Reference No. Applicant : WT05060414 EMC TEST REPORT : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Advanced surge protection Model No. : SISF, SISF-2, SISFN-BLACK,
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Variant Model Name: Applicant: CAMERA HOUSING SAMSUNG TECHWIN CO., LTD. SCX-FH200B SHB-4200 SAMSUNG TECHWIN
More information2620 Modular Measurement and Control System
European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic
More informationRevision History of Report
Revision History of Report Rev. Revisions Effect page Reviewed by Date - Initial issue All J. S. Yoon March 7, 2014 A1 Administrative change P1 and P5 J. S. Yoon March 20, 2015 (Revision A1) This amendment
More informationTEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed
17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:
More informationEMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009
Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203
More informationEMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.
EMC Testing Report Equipment Under Test: Model Number: Serial No.: Applicant: Address of Applicant: Multi-Frequency (4 Channel Selectable) Twin Photobeam Detector Dual-120CS Dual-90CS, Dual-60CS, Dual-30CS
More informationTEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated
Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances, electric tools
More informationShenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT
Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-89486194-805 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances,
More informationContents. Report No.: EMC-CE-2114 Page: 2 of 39
Page: 2 of 39 Contents 1. Applicant information... 3 2. Laboratory information... 4 3. Test system configuration... 5 3.1 Operation environment... 5 3.2 Measurement Uncertainty... 6 4. Description of E.U.T...
More informationGuangdong East Power Co., Ltd. Uninterruptible Power Systems
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012
More informationEN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd
Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE
More informationAUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN
AUSTRALIA TEST REPORT For KLM Lighting Co., Limited LED Down Light Model No.: KLM-HP30WSN Additional Model No.: KLM-SM-50-002, KLM-HP7WSS, KLM-HP10WSS, KLM-HP12WSS, KLM-HP15WSS, KLM-HP20WSS, KLM-HP30WSS,
More informationEMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U
EMC TEST REPORT For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U Prepared for Address : PEAK ELECTRONIC(HUIZHOU)CO., LTD. :
More informationEMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi
EMC TEST REPORT For Shenzhen Ruideou Keji Youxian Gongsi Product Name: Trademark: Milligram Scale WAOAW Model Number: W-01-50 Prepared For : Address: Prepared By : Address: Shenzhen Ruideou Keji Youxian
More informationEMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass
Reference No.: WTS14S0513592E Page 2 of 44 1 Test Summary EMISSION Test Item Mains Terminal Disturbance Voltage, 150kHz to 30MHz Telecommunication ports interference voltage, 150KHz to 30MHz Radiation
More informationEMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57
EMC TEST REPORT For Global Tech China Limited 120/200 Watt Mightylite Model No.: 0022031 Additional Model No: Please Refer To Page 57 Prepared for Address : Global Tech China Limited : 3 Flat A, Wai Yip
More informationEMC standards. Presented by: Karim Loukil & Kaïs Siala
Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards
More informationPage: 1 of 44 EMC TEST REPORT. : Gembird Electronics Ltd. Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China
Page: 1 of 44 Reference No. Applicant EMC TEST REPORT : WT05121033 : Gembird Electronics Ltd. Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) : Product Name :
More informationCE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10
CE/EMC TEST REPORT For HK QNOVATOR TECHNOLOGY CO.,LIMITED Product Name: Vacuum Tube Amplifier Trademark: Model Number: Prepared For: Address: Gemtune GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05,
More informationEMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)
EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday
More informationBy order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China
4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR
More informationEMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19
EMC TEST REPORT Page : 1 of 19 Equipment Under Test Model No. Applicant Address of Applicant : Bluetooth Headset : FB-HS01 : Formosa Teletek Corporation : 358, Huaya 2 nd Rd., Gueishan shiang, Taoyuan,
More informationFCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR
FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR Prepared for Address : SHENZHEN EAGLE TECHNOLOGY CO., LTD : A FIoor 1 BIdg.14, Changfeng
More informationTest Report GUANGDONG EAST POWER CO., LTD
Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA902IIRTS, EA902IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014
More informationA) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23
D I R E C T O R Y A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 B) Test data: Immunity against Electrostatic discharge
More informationReport for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B
Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed
More informationFCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U
FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U Prepared for Address : GZTOD.CO., LTD : 2-5/F, Building A4, Huimingsheng Industrial Park, Tongfuyu
More informationEMC TEST REPORT For Prokits Industries Co., Ltd.
Page 1 of 34 EMC TEST REPORT For Prokits Industries Co., Ltd. Temperature-Controlled Soldering Station Model No.:SS-206/207 Series Test Report Number : ESTSZ110701228E EST COMPLIANCE LABORATORY LIMITED
More informationOverview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University
Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted
More informationTEST REPORT TEST REPORT. Report Number : ETLE Report issue date: May 26, Address : , Gongreung-dong, Nowon-gu, Seoul, Korea
Report Number : ETLE090324.04 Report issue date: May 26, 2009 Model / Serial No. : JULIET-1 / NONE Multiple Model Name : JULIET-2, JULIET-3, ROMEO-1, ROMEO-2, ROMEO-3 Product Type : Hot & Cold Water Purifier
More informationCE EMC Test Report. Jones Tsai / Manager. SPORTON INTERNATIONAL (KUNSHAN) INC. No. 3-2, PingXiang Road, Kunshan, Jiangsu Province, P.R.C.
CE EMC Test Report APPLICANT : Quanta Computer Inc EQUIPMENT : Laptop Computer BRAND NAME : OLPC MODEL NAME : XO-1.75; XO-1.75HS STANDARD : ETSI EN 301 489-1 V1.8.1 (2008-04) ETSI EN 301 489-17 V2.1.1
More informationThe standards relevant for the evaluation of EMC requirements are as follows:
EU Declaration of Conformity EU Declaration of Conformity According to EMC Directive 2004/108/EC For the following Product : LED CONVERTER Model Name : PSDH470102B Variant Model Name : PSDH470102A Applicant
More informationSUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE
EMC TEST REPORT For SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD Product Name: Pure sine wave power inverter Trademark: Model : Prepared For : Address: Prepared By : Address: ML-1000W ML-300W---ML-8000W.
More informationEMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan
Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE
More informationEN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017
EN 301 489-17 v3.1.1 TEST REPORT FOR Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 Prepared for Texas Instrument 2900 Semiconductor Drive Santa
More informationReport No R-RFCEP02V01. Test Report. Model No. MS-N012, U110, U115 Transmitter Module. MSI / MS-6890
Test Report Product Name Notebook Model No. MS-N012, U110, U115 Transmitter Module. MSI / MS-6890 Applicant Address MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.
More informationCE TEST CERTIFICATION
according to Certification No.: E5NC004 European Standard EN 61000-6-4:2001 EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 61000-6-2:2001 ( IEC 61000-4-2:1995/A1:1998, IEC 61000-4-3: 1995/A1:1998,
More informationC E R T I F I C A T I O N
C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.
More informationTest Report. MS-1031,M640,6400,6400 series. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan
Test Report Product Name Model No. MEGA BOOK, NOTEBOOK MS-1031,M640,6400,6400 series Applicant MICRO-STAR INT L CO., LTD Address No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan Date of Receipt Mar.
More informationEMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58
EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58 Prepared for : TEA-Energy China Limited Address : 0100029 Building,
More informationCTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3150428-00472-E-R1 2/F., South Tower, Huoju Building, No.181, Canghai Road,
More information