1 Technical Data Sheet Theta Hz Theta Hz the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage. Special Features Fully onsite programmable input range Available in Single or Dual output type Onsite selectable output type.(dc current / DC voltage) Accuracy class 0.2 ( IEC / EN 60688) Seven Segment LCD Display RS485(Modbus) Communication Output Response Time < 400 msec

2 Product Features Measuring Input Sine wave or distorted wave form of nominal input voltage with fundamental wave. Analog Output (Single or dual) Accuracy Programmable Input/Output Isolated analog output which can be set onsite to either voltage or current output. Output signal accuracy Class 0.2 as per International Standard IEC / EN The Transducer can be programmed onsite using front key & display or through programming port (COM) or through RS 485. LED Indication Display Module (Optional) Rs485 Communication (Optional) LED indication for power on and output type. (Current output : Red LED, Voltage output : Green LED) Symbols and their meaning Input Frequency Start value of input Elbow value of input 2 End value of input Output DC Voltage / DC Current Start value of output DC Voltage / DC Current Elbow value of output DC Voltage / DC Current Accuracy ( Acc. to IEC / EN 60688) Reference Value Basic Accuracy Output end Value (Voltage or Current) 0.2*C Factor C (The highest value applies if calculated C is less than,then C= applies Linear characteristics Bent characteristics C= 2 or C= - 2 For : C= or C= - RN End value of output DC Voltage / DC Current Rated value of output burden For 2: C= 2 or C= UN Nominal input voltage Reference conditions for Accuracy Ambient temperature 23 C +/- C Pre-conditioning Input Variable Input waveform Sinusoidal, Form Factor.07 Input signal frequency Auxiliary supply voltage 30 min acc. to IEC / EN Rated Voltage / Rated Current 50 or 60Hz At nominal range Output Load Rn = 7.5 V / ± % With DC current output signal Rn = / ma ± % With DC voltage output signal Miscellaneous Acc. to IEC / EN Measuring Output ( Single or Optional Dual) Output type Load independent DC Voltage, DC Current onsite selectable Measuring Input through DIP switches. Frequency Transducer (Theta H2 ) Load independent DC output Measuring Ranges 0 20mA 45Hz to 55Hz, / 4 20mA 48Hz to OR 52Hz, 0 0V. Output burden with 55Hz to 65Hz, 45Hz to 65Hz 0 R 5V/ DC current output Signal (min span 4Hz) Output Nominal burden input Voltage(UN) with 57V /(2 ma) UN 500 R V DC voltage output Signal Nominal input Voltage < 0.6 VA max Current burden limit under.25 * with current output overload Overload R=0 Capacity. 200 *UN ma continuously, with Voltage output 2*UN for second, repeated 0 <.25 * with voltage output Voltage limit under R= times at 0 minute intervals (maximum 30 V with 300V current with output power Residual Ripple in supply powered from measuring % pk-pk Output signal input). Response Time < 400 msec Version No. :TAHz/205/02

3 Auxiliary Power Supply AC/DC Auxiliary Supply AC Auxiliary supply frequency range Auxiliary supply consumption 60V VAC-DC 24V...60 VAC-DC 60V 300 VAC-DC ± 5% or 24V... 60VAC-DC ± 0% 40 to 65 Hz < 8VA for Single output < 0VA for Dual output < 5 VA for Single output < 6 VA for Dual output Environmental Nominal range of use Storage temperature Relative humidity of annual mean Altitude As per IEC / EN standard Output Stability 0 to 45 C -40 C to 70 C 75% 2000m max < 30 min Output Characteristics Example of setting with Linear Characteristics : Example of setting with bent Characteristics : = Start value of input = Start value of output = Elbow value of input = Elbow value of output 2 = End value of input = End value of output Note: End value() of output cannot be changed onsite. Safety Protection Class II (Protection Isolated, EN 600) Protection IP 40, housing according to EN IP 20,terminal according to EN Pollution degree Installation Category Insulation Voltage 50Hz,min. ( EN 600-) 7700VDC, Input versus outer surface 5200VDC, Input versus all other circuits 5200VDC, Auxiliary supply versus outer surface and output 690VDC, Output versus output versus each other versus outer surface. Additional error Connection Terminal Connection Element Permissible cross section of the connection lead ±0.2% /0 C Conventional Screw type terminal with indirect wire pressure Installation Data Mechanical Housing Mounting position Weight Lexan 940 (polycarbonate) Flammability Class V-0 acc. to UL 94, self extinguishing, non dripping, free of halogen Rail mounting / wall mounting Approx. 0.4kg Version No. :TAHz/205/02

4 ON LED Aux.supply healthy condition Green LED continuous ON O/P LED Output voltage selection Output Current selection Green LED continuous ON Red LED continuous ON O/P2 LED Output2 voltage selection Output2 Current selection Green LED continuous ON Red LED continuous ON Electrical Connections Dimensions Connection Measuring input Auxilliary Power supply Measuring output - Measuring output - 2 ~ ~ ~, + ~, Terminal details Version No. :TAHz/205/02

5 of transducer can be done in three ways Via port (COM) ) Via Front LCD & two keys. 2) Via optional RS485(MODBUS) communication port ( Device address, Password,communication parameter, Output Type & simulation mode can be programmed). 3) Via port vailable at front of Theta Hz Transducers using (optional) PRKAB60 Adapter. The connections between Power supply Theta Hz Transducer DIP Switch Setting for OUTPUT Type of output (current or voltage signal) has to be set by DIP switch (see Fig.5) connector For programming of DIP switch the user needs to open the transducer housing & set the DIP switch located on PCB to the desired output type Voltage or Current. Output range changing is not possible with DIP switch setting. Transducer Programing cable PRKAB 60 Refer below Fig. 5 for DIP switch setting. The four pole DIP switch is located on the PCB in the Theta Transducer Fig. 4 Software CD ON 234 Version No. :TAHz/205/02

6 Product Code TT Input Range 45-55Hz Hz B 45-65Hz Hz A Input Range V 8F U H Power Supply 24-60U F Output O/P O 2 O/P 2O 2 Display Module With Display D Without Display WD Z RS485 Module With RS R Without RS-485 Z Prog. Cable With PRKAB 60 PRK C PRKAB 60 Z Version No. :TAHz/205/02

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type

More information

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer nalogue Meters With Moving - Iron Movement pplication IEGER PR-P The iegler PR-P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase

More information

SUBJECT TO CHANGE WITHOUT NOTICE

SUBJECT TO CHANGE WITHOUT NOTICE TRNSUCERS & ISTRS Theta 30P www.sifamtinsley.co.uk TSHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders igital Panel Meters Current Transformers

More information

SINEAX U 553 Transducer for AC Voltage

SINEAX U 553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U 55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out. Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta

More information

EMBSIN 281 G Power factor transducer

EMBSIN 281 G Power factor transducer EMBSI 8 G Carrying rail housing MBS/SP Application The transducer EMBSI 8 G (Fig. ) measures the power factor between current and voltage of a single or 3-phase balanced network having a sine wave form.

More information

SINEAX G 536 Phase Angle or Power Factor Transducer

SINEAX G 536 Phase Angle or Power Factor Transducer SIEAX G Carrying rail housing P/0 Application The transducer SIEAX G (Fig. ) measures the phase angle or power factor between current and voltage of a single or -phase balanced network having a sine wave

More information

SINEAX I 552 Transducer for AC current

SINEAX I 552 Transducer for AC current SNEAX 55 With power supply RMS value measurement, with measuring ranges Carrying rail housing P/0 Application he transducer SNEAX 55 (Fig. ) converts a sinusoidal or a distorted AC current into a load

More information

RISH Ducer E13 3 channel transducer for AC current and voltage

RISH Ducer E13 3 channel transducer for AC current and voltage RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments

More information

RISH CON - Hz FREQUENCY TRANSDUCER

RISH CON - Hz FREQUENCY TRANSDUCER RISH CON - Hz FREQUENC TRANSDUCER Data Sheet Trasducer for measurig Frequecy Hz www.rishabh.co.i Page of 5 Versio: D 04 / 0 / Applicatio : The Rish CON - Hz trasducer is used for frequecy measuremet. The

More information

POWER \ PHASE ANGLE \ POWER FACTOR TRANSDUCER RISH

POWER \ PHASE ANGLE \ POWER FACTOR TRANSDUCER RISH Operating Manual POWER \ PHASE ANGLE \ POWER FACTOR TRANSDUCER RISH CON - P ON O/P1 O/P2 COM RISH CON - P IC :15001143 Rev.B - 17/12/13 POWER \ PHASE ANGLE \ POWER FACTOR TRANSDUCER POWER \ PHASE ANGLE

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power

More information

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar SINEAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. ) is to electrically insulate input and

More information

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output

More information

SINEAX G 537 Transducer for Phase Angle Difference

SINEAX G 537 Transducer for Phase Angle Difference Carrying rail housing P/0 pplication The transducer SINX G 5 (Fig. ) converts the phase angle difference of two synchronised supplies into a load independent DC current or a load independent DC voltage

More information

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX TV809, 1 channel Programmable Isolating Amplifier For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz

More information

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay Technical Datasheet RELAY-1 RISHABH k V RESET True RMS Digital Protection Relay RELAY-2 TEST True RMS Measurement RISH Relay V is used to protect against Over Voltage, Under Voltage, Phase Sequence detection,

More information

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions Installation and start up instructions TAS-311DG Selectable AC transducer Voltage, current, frequency or phase angle transducer Supply voltage up to 690V DEIF A/S Configuration via PC-interface possible

More information

Programmable AC Current Transducer MT418

Programmable AC Current Transducer MT418 Programmable AC Current Transducer MT418 RMS AC current measurements Current auto range measurements up to 12 A Frequency measurement range 16 400 Hz AC or universal wide auiliary power supply range 24

More information

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay Technical Datasheet RELAY-1 RELAY-2 k V Hz RESET ABH TEST True RMS Measurement True RMS Digital Protection V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,

More information

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate

More information

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics RISH Ducer E13 Transducer For c Current Or c Voltage With Different Characteristics Data Sheet For Measurement of C Current or C Voltage Fig. 1. RISH Ducer E13 clipped onto a top - hat rail. Fig. 2. RISH

More information

Programmable AC Voltage Transducer MT416

Programmable AC Voltage Transducer MT416 Programmable AC Voltage Transducer MT416 RMS AC voltage or frequency measurements Voltage auto measurements up to 600 V L-N Frequency measurement 16 400 Hz AC or universal wide auiliary power 24 300 Vdc,

More information

Totalizing Counters mini-i

Totalizing Counters mini-i mini-i Type 634/635 Type 634: Counter with high immunity against magnetic interfere Type 635: Counter with high shock stability Miniature size Low power consumption Electrical connections in standard grid

More information

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay Line Monitoring Technical Datasheet RISH RELAY-1 RELAY-2 RISHABH k V Hz True RMS Digital Protection RISH V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,

More information

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS RISH Ducer 5 TRNSDUCR FOR C CURRNT OR C VOLTG WITH DIFFRNT CHRCTRISTICS The RISH Ducer 5 transducer (Fig and ) is used where a sine-wave C current or voltage is to be converted into a DC signal proportional

More information

Product Guide. Transducers

Product Guide. Transducers x y Product Guide Transducers 800.U.001.01 P/Q f for AC Current or AC Voltage: A1U / V1U 2.2 also self-powered: AU / VU 2.0 for Active or Reactive Power in single phase systems: EW / EB 2.2 in balanced

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

DATA SHEET Selectable AC transducer TAS-311DG

DATA SHEET Selectable AC transducer TAS-311DG DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

AMIK 200 / 201 Technical Data Sheet

AMIK 200 / 201 Technical Data Sheet AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT

More information

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2 Data Sheet 066.8e Transducers for Active and Reactive Power EW 2.2 DGW 2.2 VGW 2.2 DUW 2.2 VUW 2.2 Application The E/DG/VG/DU/VU W 2.2 power transducers convert all forms of active and reactive power polarity

More information

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs Plug-in module, or channels Application The programmable transmitter (Fig. ) is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple non-linearities

More information

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR The T-W or T-V power transducer converts ac current and voltage signals into a load independent dc signal proportional to active power (watts)

More information

Universal measuring transducer

Universal measuring transducer Universal measuring transducer EM4000 Compact housing High accuracy Full galvanic separation MODbus (RS232/RS485) 3 Analogue + 1 Pulse output Direct voltagemeasurement up to 690V 48 hour service EXW ELEQ

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features: Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

Coupling Relays and Converters

Coupling Relays and Converters Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Primary switched-mode power supply units In standard machine production, the requirements for a power supply unit are mostly specified in advance. Here, the TRIO POWER power supply units are suitable which

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Front dimensions: 9 DIN modules Analogue output by means of optional module (20mA or 10VDC) RS 422/485 Serial port by means of

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters

More information

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features Measuring Transducers Transducing electrical quantities Iskra MIS d.d. Measuring Transducers Features AC, DC POWER SYSTEM MEASUREMENT MICROPROCESSOR CONTROL HOUSING FOR DIN RAIL MOUNTING IN COMPLIANCE

More information

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK PP, PP and PB ISO 900 C E R T Y F I K A T 4 mm SERVICE MANUAL Contents Page. APPLICATION... 2. BASIC REQUIREMENTS.... TRANSDUCER SET... 4 4. TECHNICAL

More information

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous

More information

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS Application: The Jewell DPM Power 96x96 series measures system active Power (Import/Export), Reactive Power (Import/Export), Apparent Power & Power Factor of Three Phase and Single Phase Network. It has

More information

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy

More information

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet Datasheet Article No: 136-5385 Digital AC Ammeter, 48x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5387 Digital AC Ammeter, 96x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5388 Digital

More information

Paladin Transducers 250 Series Class 0.5 and Class 0.2

Paladin Transducers 250 Series Class 0.5 and Class 0.2 Paladin Transducers 250 Series Class 0.5 and Class 0.2 An extensive range of transducers providing measurement, isolation and conversion of electrical parameters into industry standard DC output signals.

More information

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet AMIK 300 / 301 USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important

More information

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum

More information

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG Compact design, 55 x 75 mm Easily accessible terminals Accuracy class 0.5 35 mm DIN rail or base mounting DEIF A/S Frisenborgvej 33

More information

AMIK Three Phase Digital Panel Meters

AMIK Three Phase Digital Panel Meters AMIK Three Phase Digital Panel Meters USA SICE 1936 ELIAILIT EOD MEASUE Special Features 3 Line 4 Digits ultra bright LED Display (up to 9999) On site Programmable CT/PT atios User selectable CT Secondary

More information

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External

More information

8V General information. 2 Order data 8V

8V General information. 2 Order data 8V 8V05.00-8V05.00- General information Modular mechanical design using plug-in modules Integrated line filter Integrated braking resistor All connections are made using plug-in connectors Integrated electronic

More information

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management Modular Smart Power Transducer Type SPT-90 Energy Management Modular Smart Power Transducer Type SPT-90 Class 0.5 (current/voltage) 16-bit µp-based modular smart power transducer Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C. ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

JUMO Wtrans Receiver with Wireless Data Transmission

JUMO Wtrans Receiver with Wireless Data Transmission Data Sheet 902931 Page 1/10 JUMO Wtrans Receiver with Wireless Data Transmission k For measuring temperature, pressure, potentiometer, and voltage. k Interface RS485 with Modbus protocol k Wireless measured

More information

Zelio Control Measurement Relays

Zelio Control Measurement Relays Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and

More information

MBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting

MBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting EMBSIN 120 UV Measuring transducers for AC current : Sinus-shaped alternating voltage (0 20 A or 0 500 V) : Unipolar output signal measuring principle: Rectifier mean value measurement process economic

More information

Power Meter Series PM3200 Functions and characteristics

Power Meter Series PM3200 Functions and characteristics Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring

More information

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description. Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed

More information

Measuring centers MC7x0 series Multifunction Meter MC740

Measuring centers MC7x0 series Multifunction Meter MC740 Measuring centers MC7x0 series Multifunction Meter MC740 o Measurements of instantaneous values of more than 130 quantities (U, I, P, Q, S, PF, PA, f, φ, THD, MD, energy, energy cost by tariffs, etc.)

More information

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output) MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.

More information

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes Data sheet 902931 Page 1/10 JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes For processing physical measurands of the JUMO Wtrans series RS485 interface with Modbus protocol

More information

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters

More information

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet Datasheet ENGLISH Article No: 136-5390 Digital AC Ammeter, 48x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5391 Digital AC Ammeter, 96x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5393

More information

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description Universal current transducer Data sheet 104059_en_05 PHOENIX CONTACT 2011-03-09 1 Description MCR-SL-CUC-...-I and MCR-SL-CUC-...-U active current transducers convert DC, AC, and distorted currents into

More information

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

Jewell DPM EINE BEST IN CLASS

Jewell DPM EINE BEST IN CLASS Application: Silent Features: The digital panel meter has been designed Fast & Easy installation on panel with the for industrial applications, which help of external swivel screws. frequently require

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

Note The module converts unipolar and bipolar input signals

Note The module converts unipolar and bipolar input signals PROGRAMMABLE ANALOG SIGNAL CONVERTER THREE WAY GALVANIC ISOLATOR - 19 input scales - 7 output scales - 1 SPDT alarm contact - input/output isolation 3kV - auxiliary supply output for loop powered sensors

More information

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN Energy Management Energy Analyzer Type EM11 DIN Other versions available (not certified, option X): see how to order on the next page Product Description Class 1 (kwh) according to EN62053-21 Class B (kwh)

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96 Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

RISH Ducer IXX / VXX Series (TRMS/Average) Transducer for AC current / AC Voltage (Single or Dual Output)

RISH Ducer IXX / VXX Series (TRMS/Average) Transducer for AC current / AC Voltage (Single or Dual Output) RISH Ducer IXX / VXX Series (TRMS/verage) Transducer for C current / C Voltage (Single or Dual Output) Data Sheet Transducer for C Current and C Voltage Fig. 1. RISH Ducer I11 in housing E16 clipped onto

More information